AC-ANALOG-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI TAddress, DisplayString, DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC IpAddress FROM RFC1155-SMI Unsigned32, Integer32, enterprises FROM SNMPv2-SMI SnmpAdminString FROM SNMP-FRAMEWORK-MIB audioCodes, acRegistrations, acGeneric, acProducts,acBoardMibs FROM AUDIOCODES-TYPES-MIB; acAnalog MODULE-IDENTITY LAST-UPDATED "201207260446Z" --Thursday, July 26 2012 ORGANIZATION "AudioCodes Ltd" CONTACT-INFO "Postal: Support AudioCodes LTD 1 Hayarden Street Airport City Lod, ISRAEL 70151 Tel: 972-3-9764000 Fax: 972-3-9764040 Email: support@audiocodes.com Web: www.audiocodes.com" DESCRIPTION "" ::= {acBoardMibs 8} acAnalogConfiguration OBJECT IDENTIFIER ::= {acAnalog 1} acAnalogConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 1} acAnalogMisc OBJECT IDENTIFIER ::= {acAnalogConfig 1} acAnalogMiscCurrentDisconnectDuration OBJECT-TYPE SYNTAX Unsigned32 (200..1500) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the current-disconnect duration (in msec). This value is used in generation and detection. Access: Offline. AC INI-Param: CurrentDisconnectDuration" ::= {acAnalogMisc 1} acAnalogMiscFlashHookPeriod OBJECT-TYPE SYNTAX Unsigned32 (25..3000) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the flashhook period (in msec) for both analog and IP sides. For the analog side it defines: - The maximal hook-flash detection period (for FXS gateways). A longer signal is considered offhook / onhook event. - The hook-flash generation period (for FXO gateways). For the IP side it defines the flash-hook period that is reported to IP. The valid range is 25 to 1500. The default value is 700 msec. Note: For FXO gateways, a constant of 90 msec must be added to the required hook-flash period. For example, to generate a 450 msec hook-flash, set ‘FlashHookPeriod’ to 540. . Access: Instant. AC INI-Param: FLASHHOOKPERIOD" ::= {acAnalogMisc 2} acAnalogMiscGroundKeyDetection OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/disables the analog ground key detection. 0 = Disable 1= Enable. Access: Offline. AC INI-Param: GroundKeyDetection" ::= {acAnalogMisc 3} acAuxiliaryFiles OBJECT IDENTIFIER ::= {acAnalogConfig 2} acAuxiliaryFilesFxsCoefficients OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..47)) MAX-ACCESS read-only STATUS current DESCRIPTION "Defines the FXS loop coefficient filename. Max. 47 characters. AC INI-Param: FXSCOEFFILENAME" ::= {acAuxiliaryFiles 1} acAuxiliaryFilesFxoCoefficients OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..47)) MAX-ACCESS read-only STATUS current DESCRIPTION "Defines the FXO loop coefficient filename. Max. 47 characters. AC INI-Param: FXOCOEFFILENAME" ::= {acAuxiliaryFiles 2} acAnalogFxoConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 2} acAnalogFxo OBJECT IDENTIFIER ::= {acAnalogFxoConfig 1} acAnalogFxoFarEndDisconnectType OBJECT-TYPE SYNTAX Unsigned32 (0..128) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter sets the source for the acEV_FAR_END_DISCONNECTED event (or for the relevant control protocol event). It is a bit field parameter, hence (for example) if both CPT and current disconnect are required, the parameter should be set to 5. FarDisconnect contributor: 1 = CPT 2 = PolarityReversal 4 = CurrentDisconnect 8 = Silence. Access: Offline. AC INI-Param: FARENDDISCONNECTTYPE" ::= {acAnalogFxo 1} acAnalogFxoCountryCoefficients OBJECT-TYPE SYNTAX INTEGER { europe(66) , unitedStates(70) } MAX-ACCESS read-write STATUS current DESCRIPTION "Allows the user to modify the line characteristic (AC and DC) according to country. Access: Offline. AC INI-Param: CountryCoefficients" ::= {acAnalogFxo 2} acAnalogFxoDCRemover OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines whether to enable the analog DC remover in the DAA. One of the following values: 0 = DC remover is disabled 1 = DC remover is enabled. Access: Offline. AC INI-Param: EnableAnalogDCRemover" ::= {acAnalogFxo 3} acAnalogFxoDefaultLinePolarityState OBJECT-TYPE SYNTAX INTEGER { positive-polarity(0) , negative-polarity(1) , polarity-auto-detect(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the TTX pulses voltage level. 0 = 0Vrms sinusoidal bursts 1 = 0.5Vrms sinusoidal bursts 2 = 1Vrms sinusoidal bursts. Access: Offline. AC INI-Param: SetDefaultLinePolarityState" ::= {acAnalogFxo 4} acAnalogFxoTxGainControl OBJECT-TYPE SYNTAX Integer32 (-15..12) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets gain\attenuation of the FXO Tx path between -15db and 12db. default no gain. Access: Offline. AC INI-Param: FXOTxGainControl" ::= {acAnalogFxo 5} acAnalogFxoRxGainControl OBJECT-TYPE SYNTAX Integer32 (-15..12) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets gain\attenuation of the FXO Rx path between -15db and 12db. default no gain. Access: Offline. AC INI-Param: FXORxGainControl" ::= {acAnalogFxo 6} -- **************************************** -- acAnalogFxoFarEndDisconnectTone table declaration -- **************************************** acAnalogFxoFarEndDisconnectToneTable OBJECT-TYPE SYNTAX SEQUENCE OF AcAnalogFxoFarEndDisconnectToneEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acAnalogFxo 21} -- **************************************** -- acAnalogFxoFarEndDisconnectTone table entry -- **************************************** acAnalogFxoFarEndDisconnectToneEntry OBJECT-TYPE SYNTAX AcAnalogFxoFarEndDisconnectToneEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acAnalogFxoFarEndDisconnectToneIndex} ::= {acAnalogFxoFarEndDisconnectToneTable 1} -- **************************************** -- acAnalogFxoFarEndDisconnectTone TABLE -- **************************************** AcAnalogFxoFarEndDisconnectToneEntry ::= SEQUENCE { acAnalogFxoFarEndDisconnectToneRowStatus Unsigned32, acAnalogFxoFarEndDisconnectToneAction Unsigned32, acAnalogFxoFarEndDisconnectToneActionResult Unsigned32, acAnalogFxoFarEndDisconnectToneIndex Unsigned32, acAnalogFxoFarEndDisconnectToneType INTEGER } acAnalogFxoFarEndDisconnectToneRowStatus OBJECT-TYPE SYNTAX Unsigned32 (1..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Far End Disconnect table row-status. AC INI-Param: N/A" ::= {acAnalogFxoFarEndDisconnectToneEntry 1} acAnalogFxoFarEndDisconnectToneAction OBJECT-TYPE SYNTAX Unsigned32 (0..0) MAX-ACCESS read-write STATUS current DESCRIPTION "Far End Disconnect table action. AC INI-Param: N/A" ::= {acAnalogFxoFarEndDisconnectToneEntry 2} acAnalogFxoFarEndDisconnectToneActionResult OBJECT-TYPE SYNTAX Unsigned32 (0..0) MAX-ACCESS read-only STATUS current DESCRIPTION "Far End Disconnect table result. AC INI-Param: N/A" ::= {acAnalogFxoFarEndDisconnectToneEntry 3} acAnalogFxoFarEndDisconnectToneIndex OBJECT-TYPE SYNTAX Unsigned32 (0..4) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table use. AC INI-Param: N/A" ::= {acAnalogFxoFarEndDisconnectToneEntry 4} acAnalogFxoFarEndDisconnectToneType OBJECT-TYPE SYNTAX INTEGER { acNullTone(0) , acDialTone(1) , acRingingTone(2) , acBusyTone(3) , acCongestionTone(4) , acSpecialInfoTone(5) , acWarningTone(6) , acReorderTone(7) , acConfirmationTone(8) , acWaitingTone(9) , acCallProgressCo1Tone(10) , acCallProgressCo2Tone(11) , acOldMilliwattTone(12) , acNewMilliwattTone(13) , acMessageWaitingIndicator(14) , acStutterDialTone(15) , acStutterOffHookWarningTone(16) , acWaitingTone1(17) , acComfortTone(18) , acNAKTone(19) , acVacantNumberTone(20) , acSpecialConditionTone(21) , acDialTone2(22) , acOnHoldTone(23) , acCallTransferDialTone(24) , acCallForwardTone(25) , acCreditCardServiceTone(26) , acSpecialRecallDialTone(27) , acAlertingTone(28) , acNetworkCongestionTone(29) , acWaitingTone2(30) , acWaitingTone3(31) , acWaitingTone4(32) , acConfEnterTone(33) , acConfExitTone(34) , acConfLockTone(35) , acConfUnlockTone(36) , acConfTimeLimitTone(37) , acPayphoneRecognitionTone(38) , acCallerWaitingTone(39) , acCNGFaxTone(40) , acPrecConfNotifyType(41) , acPresConfNotifyType(42) , acPrecPreemptType(43) , acPrecRTType(44) , acR15reqOfANItone(45) , acCo1Tone(200) , acCo2Tone(201) , acPlayRecordBeepTone(202) , acTrunkTestingTestProgressTone(203) , acTrunkTestingTestTone(204) , acTrunkTestingGuardTone(205) , acFSKTrunkTestingTone(206) , acGeneralTrunkTestingTone1(207) , acGeneralTrunkTestingTone2(208) , acGeneralTrunkTestingTone3(209) , acSpecialInfoToneFirst(210) , acSpecialInfoToneSecond(211) , acSpecialInfoToneThird(212) , acTTYTone(213) , acTT904ContinuityTone(214) , acTTMilliwattLossMeasureTone(215) , acCarrierDialTone(216) , acCarrierAnswerTone(217) , acCarrierChargingTone(218) , acLongDistanceIndicatorTone(219) , acSTUModemFirstTone(298) , acSTUModemSecondTone(299) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines which CPT types are detected as far-end disconnect. The CPT type is based on the acTCallProgressToneType enum. This is valid when FarEndDisconnectType allows CPT detection. Range = An array of up to 4 tone types. Access: Offline. AC INI-Param: DISCONNECTTONETYPE" ::= {acAnalogFxoFarEndDisconnectToneEntry 5} acAnalogFxsConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 3} acAnalogFxs OBJECT IDENTIFIER ::= {acAnalogFxsConfig 1} acAnalogFxsPolarityReversalType OBJECT-TYPE SYNTAX INTEGER { soft(0) , hard(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the type of the polarity reversal signal used for the network far-end answer and disconnect indications. Smooth reversal prevents negative effects as non-required ringing. 0 = Soft reverse polarity 1 = Hard reverse polarity. Access: Offline. AC INI-Param: POLARITYREVERSALTYPE" ::= {acAnalogFxs 1} acAnalogFxsMeteringType OBJECT-TYPE SYNTAX INTEGER { mt12kHz(0) , mt16kHz(1) , mtPolarityReversal(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the metering method for charging pulses. 0 = 12 kHz sinusoidal bursts 1 = 16 kHz sinusoidal bursts 2 = Polarity Reversal pulses. Access: Offline. AC INI-Param: METERINGTYPE" ::= {acAnalogFxs 2} acAnalogFxsLifeLineType OBJECT-TYPE SYNTAX INTEGER { acLifeLineType-Hardware-Only(0) , acLifeLineTypeHardware-And-Link-Detection(1) , acLifeLineType-Hardware-And-Link-And-Network-Detection(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the Lifeline phone type. The Lifeline phone is available (for FXS only) on port 4 in MP-104 and MP-108, on port 2 in MP-102, on ports 1-4 in the MP-118, and on port 2 of each analog module in the Mediant 1000. 0 = activate Lifeline phone on power down 1 = activate Lifeline phone on power down or on detection of LAN disconnect 2 = activate Lifeline phone on power down, or on detection of LAN disconnect, or on loss of ping. Access: Offline. AC INI-Param: LIFELINETYPE" ::= {acAnalogFxs 3} acAnalogFxsMinFlashHookTime OBJECT-TYPE SYNTAX Unsigned32 (25..300) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the minimal time (in msec) for detection of a flash-hook event (for FXS only). The valid range is 25 to 300. The default value is 300 msec. Detection is guaranteed for flash hook periods of at least 60 msec (when setting the minimal time to 25). Flash-hook signals that last a shorter period of time are ignored. Note: It is recommended to reduce the detection time by 50 msec from the desired value (e.g. if you set the value as 200 msec, then enter 150 msec, i.e. 200 minus 50). . Access: Offline. AC INI-Param: MINFLASHHOOKTIME" ::= {acAnalogFxs 4} acAnalogFxsCallerIDTimingMode OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the Analog CallerID Timing Mode. 0 = CallerID transferred between first and second rings 1 = CallerID transferred on valid Off ring. Access: Offline. AC INI-Param: ANALOGCALLERIDTIMINGMODE" ::= {acAnalogFxs 5} acAnalogFxsBellcoreCallerIDTypeOneSubStandard OBJECT-TYPE SYNTAX INTEGER { bellcore-Between-Rings(0) , bellcore-Not-Ring-Related(1) , bellcore-Before-Ring-RP-AS(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the sub-standard of the Bellcore Caller ID type. 0 = Between_Rings 1 = Not_Ring_Related 2 = Before_Ring_RP_AS. Access: Offline. AC INI-Param: BellcoreCallerIDTypeOneSubStandard" ::= {acAnalogFxs 6} acAnalogFxsETSICallerIDTypeOneSubStandard OBJECT-TYPE SYNTAX INTEGER { eTSI-Between-Rings(0) , eTSI-Before-Ring-DT-AS(1) , eTSI-Before-Ring-RP-AS(2) , eTSI-Before-Ring-LR-DT-AS(3) , eTSI-Not-Ring-Related-DT-AS(4) , eTSI-Not-Ring-Related-RP-AS(5) , eTSI-Not-Ring-Related-LR-DT-AS(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the number denoting the ETSI CallerID Type 1 sub-standard. Either: 0 = ETSI_Between_Rings 1 = ETSI_Before_Ring_DT_AS 2 = ETSI_Before_Ring_RP_AS 3 = ETSI_Before_Ring_LR_DT_AS 4 = ETSI_Not_Ring_Related_DT_AS 5 = ETSI_Not_Ring_Related_RP_AS 6 = ETSI_Not_Ring_Related_LR_DT_AS. Access: Offline. AC INI-Param: ETSICallerIDTypeOneSubStandard" ::= {acAnalogFxs 7} acAnalogFxsETSIVMWITypeOneStandard OBJECT-TYPE SYNTAX INTEGER { eTSI-VMWI-Between-Rings(0) , eTSI-VMWI-Before-Ring-DT-AS(1) , eTSI-VMWI-Before-Ring-RP-AS(2) , eTSI-VMWI-Before-Ring-LR-DT-AS(3) , eTSI-VMWI-Not-Ring-Related-DT-AS(4) , eTSI-VMWI-Not-Ring-Related-RP-AS(5) , eTSI-VMWI-Not-Ring-Related-LR-DT-AS(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the number denoting the ETSI VMWI Type 1 Standard. Choose: 0 = ETSI_VMWI_Between_Rings 1 = ETSI_VMWI_Before_Ring_DT_AS 2 = ETSI_VMWI_Before_Ring_RP_AS 3 = ETSI_VMWI_Before_Ring_LR_DT_AS 4 = ETSI_VMWI_Not_Ring_Related_DT_AS 5 = ETSI_VMWI_Not_Ring_Related_RP_AS 6 = ETSI_VMWI_Not_Ring_Related_LR_DT_AS. Access: Offline. AC INI-Param: ETSIVMWITypeOneStandard" ::= {acAnalogFxs 8} acAnalogFxsBellcoreVMWITypeOneStandard OBJECT-TYPE SYNTAX INTEGER { bellcore-VMWI-Between-Rings(0) , bellcore-VMWI-Not-Ring-Related(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Use this parameter to select the Bellcore VMWI standard. 0 - Between_Rings 1 - Not_Ring_Related. Access: Offline. AC INI-Param: BellcoreVMWITypeOneStandard" ::= {acAnalogFxs 9} acAnalogFxsDisableAutoCalibration OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Determines whether to enable the analog Autocalibration in the DAA. One of the following values: 0 = Auto calibration is enabled 1 = Auto calibration is disabled. Access: Offline. AC INI-Param: DisableAnalogAutoCalibration" ::= {acAnalogFxs 10} acAnalogFxsExternalLifeLinePorts OBJECT-TYPE SYNTAX Unsigned32 (0..24) MAX-ACCESS read-write STATUS current DESCRIPTION "Set the amount of FXS ports which will be connected to an external life line and will be disabled (max value is half of the FXS ports). Access: Offline. AC INI-Param: ExternalLifeLinePorts" ::= {acAnalogFxs 11} acAnalogFxsCountryCoefficients OBJECT-TYPE SYNTAX INTEGER { europe(66) , unitedStates(70) } MAX-ACCESS read-write STATUS current DESCRIPTION "Allows the user to modify the line characteristic (AC and DC) according to country. Access: Offline. AC INI-Param: FXSCountryCoefficients" ::= {acAnalogFxs 12} acAnalogFxsTTXVoltageLevel OBJECT-TYPE SYNTAX INTEGER { notAvailable(-1) , ttxVoltageLevel0V(0) , ttxVoltageLevel05(1) , ttxVoltageLevel1V(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the TTX pulses voltage level. 0 = 0Vrms sinusoidal bursts 1 = 0.5Vrms sinusoidal bursts 2 = 1Vrms sinusoidal bursts -1 = notAvailable. Access: Offline. AC INI-Param: AnalogTTXVoltageLevel" ::= {acAnalogFxs 13} acAnalogEMConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 4} acAnalogEM OBJECT IDENTIFIER ::= {acAnalogEMConfig 1} acAnalogEMVoiceType OBJECT-TYPE SYNTAX INTEGER { twoWire(0) , fourWire(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "E&M Voice Configuration Type 2 or 4 wire. Access: Offline. AC INI-Param: EnMVoiceType" ::= {acAnalogEM 1} acAnalogEMInterfaceType OBJECT-TYPE SYNTAX INTEGER { signaling(0) , trunking(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "E&M Signaling Type - Trunking or Signaling. Access: Offline. AC INI-Param: EnMSystemType" ::= {acAnalogEM 2} acAnalogEMSignalingType OBJECT-TYPE SYNTAX Unsigned32 (1..5) MAX-ACCESS read-write STATUS current DESCRIPTION "Set E&M standatd signaling types are described in TIA/EIA-464C. Access: Offline. AC INI-Param: EnMSignalingType" ::= {acAnalogEM 3} acAnalogEMPortRXGain OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Rx Gain. Access: Offline. AC INI-Param: EnMPortRXGain" ::= {acAnalogEM 4} acAnalogEMPortTXGain OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Tx Gain. Access: Offline. AC INI-Param: EnMPortTXGain" ::= {acAnalogEM 5} acAnalogEMCountryCoefficients OBJECT-TYPE SYNTAX INTEGER { unitedStates(0) , europe(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "E&M Country Coefficients. Access: Offline. AC INI-Param: EnMCountryCoefficients" ::= {acAnalogEM 6} acAnalogEMHookDebounceTiming OBJECT-TYPE SYNTAX Unsigned32 (30..150) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the on E&M hook detection debounce timing. Access: Offline. AC INI-Param: EnMhookDebounceTiming" ::= {acAnalogEM 7} acAnalogEMOffHookGlareEnable OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Protect the EnM port from Rx and Tx hook collision. Access: Offline. AC INI-Param: EnMOffHookGlareEnable" ::= {acAnalogEM 8} acAnalogStatus OBJECT IDENTIFIER ::= {acAnalog 2} acAnalogStatusMisc OBJECT IDENTIFIER ::= {acAnalogStatus 1} acAnalogStatusMiscFxsOrFxo OBJECT-TYPE SYNTAX INTEGER { fXO(0) , fXS(1) , eANDm(2) , fXOandFXS(3) , fXOandFXSandEM(5) , fXOandEM(6) , fXSandEM(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Board is Fxs,Fxo, FXS_FXO or E&M. AC INI-Param: N/A" ::= {acAnalogStatusMisc 1} acAnalogStatusMiscBoardTemperature OBJECT-TYPE SYNTAX Unsigned32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of the board in degrees Celsius, should not go higher then 60!. AC INI-Param: N/A" ::= {acAnalogStatusMisc 2} acAnalogStatusMiscAnalogChannelsCount OBJECT-TYPE SYNTAX Unsigned32 (0..5000) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of the Analog channels in the board. AC INI-Param: N/A" ::= {acAnalogStatusMisc 3} acAnalogFxsFxo OBJECT IDENTIFIER ::= {acAnalogStatus 20} -- **************************************** -- acAnalogFxsFxo table declaration -- **************************************** acAnalogFxsFxoTable OBJECT-TYPE SYNTAX SEQUENCE OF AcAnalogFxsFxoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acAnalogFxsFxo 1} -- **************************************** -- acAnalogFxsFxo table entry -- **************************************** acAnalogFxsFxoEntry OBJECT-TYPE SYNTAX AcAnalogFxsFxoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acAnalogFxsFxoIndex} ::= {acAnalogFxsFxoTable 1} -- **************************************** -- acAnalogFxsFxo TABLE -- **************************************** AcAnalogFxsFxoEntry ::= SEQUENCE { acAnalogFxsFxoIndex Unsigned32, acAnalogFxsFxoType INTEGER, acAnalogFxsFxoChipRevNum Unsigned32, acAnalogFxsFxoHookState INTEGER } acAnalogFxsFxoIndex OBJECT-TYPE SYNTAX Unsigned32 (0..24) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for table use. AC INI-Param: N/A" ::= {acAnalogFxsFxoEntry 1} acAnalogFxsFxoType OBJECT-TYPE SYNTAX INTEGER { fXO(0) , fXS(1) , eM(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Line is Fxs, Fxo or E&M. AC INI-Param: N/A" ::= {acAnalogFxsFxoEntry 2} acAnalogFxsFxoChipRevNum OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Fxs/Fxo's Chip revision number. AC INI-Param: N/A" ::= {acAnalogFxsFxoEntry 3} acAnalogFxsFxoHookState OBJECT-TYPE SYNTAX INTEGER { onHookState(1) , offHookState(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The hook state of the analog line. AC INI-Param: N/A" ::= {acAnalogFxsFxoEntry 4} acAnalogAction OBJECT IDENTIFIER ::= {acAnalog 3} acAnalogFxoAction OBJECT IDENTIFIER ::= {acAnalogAction 1} -- **************************************** -- acAnalogFxoLineTest table declaration -- **************************************** acAnalogFxoLineTestTable OBJECT-TYPE SYNTAX SEQUENCE OF AcAnalogFxoLineTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acAnalogFxoAction 1} -- **************************************** -- acAnalogFxoLineTest table entry -- **************************************** acAnalogFxoLineTestEntry OBJECT-TYPE SYNTAX AcAnalogFxoLineTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acAnalogFxoLineTestIndex} ::= {acAnalogFxoLineTestTable 1} -- **************************************** -- acAnalogFxoLineTest TABLE -- **************************************** AcAnalogFxoLineTestEntry ::= SEQUENCE { acAnalogFxoLineTestIndex Unsigned32, acAnalogFxoLineTestActivate INTEGER, acAnalogFxoLineTestHookState INTEGER, acAnalogFxoLineTestPolarityStatus INTEGER, acAnalogFxoLineTestLineConnectionStatus INTEGER, acAnalogFxoLineTestLineCurrent Integer32, acAnalogFxoLineTestLineVoltage Integer32, acAnalogFxoLineTestRingState INTEGER, acAnalogFxoLineTestLinePolarity INTEGER, acAnalogFxoLineTestMwiState INTEGER, acAnalogFxoLineTestLastCurrentDisconnectDuration Unsigned32 } acAnalogFxoLineTestIndex OBJECT-TYPE SYNTAX Unsigned32 (0..24) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for table use. AC INI-Param: N/A" ::= {acAnalogFxoLineTestEntry 1} acAnalogFxoLineTestActivate OBJECT-TYPE SYNTAX INTEGER { noTestActivated(0) , runLineTest(1) , lineTestDone(2) , testFailed(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Activate line testing in an FXO analog line according to a given line-index. AC INI-Param: N/A" ::= {acAnalogFxoLineTestEntry 2} acAnalogFxoLineTestHookState OBJECT-TYPE SYNTAX INTEGER { onHookState(1) , offHookState(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The hook state of the analog line. AC INI-Param: N/A" ::= {acAnalogFxoLineTestEntry 3} acAnalogFxoLineTestPolarityStatus OBJECT-TYPE SYNTAX INTEGER { normalPolarity(1) , reversePolarity(2) , notAvailable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The line's polarity state. AC INI-Param: N/A" ::= {acAnalogFxoLineTestEntry 4} acAnalogFxoLineTestLineConnectionStatus OBJECT-TYPE SYNTAX INTEGER { lineDisconnected(1) , lineConnected(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The connection's status of the line. AC INI-Param: N/A" ::= {acAnalogFxoLineTestEntry 5} acAnalogFxoLineTestLineCurrent OBJECT-TYPE SYNTAX Integer32 (-1..24) MAX-ACCESS read-only STATUS current DESCRIPTION "The line's current [ma]. AC INI-Param: N/A" ::= {acAnalogFxoLineTestEntry 6} acAnalogFxoLineTestLineVoltage OBJECT-TYPE SYNTAX Integer32 (-128..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The line's voltage [V]. AC INI-Param: N/A" ::= {acAnalogFxoLineTestEntry 7} acAnalogFxoLineTestRingState OBJECT-TYPE SYNTAX INTEGER { off(1) , on(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Ring's State. AC INI-Param: N/A" ::= {acAnalogFxoLineTestEntry 8} acAnalogFxoLineTestLinePolarity OBJECT-TYPE SYNTAX INTEGER { positive(1) , negative(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The line's polarity state. AC INI-Param: N/A" ::= {acAnalogFxoLineTestEntry 9} acAnalogFxoLineTestMwiState OBJECT-TYPE SYNTAX INTEGER { off(1) , on(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Mwi's state. AC INI-Param: N/A" ::= {acAnalogFxoLineTestEntry 10} acAnalogFxoLineTestLastCurrentDisconnectDuration OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Last current disconnect duration in msec. AC INI-Param: N/A" ::= {acAnalogFxoLineTestEntry 11} acAnalogFxsAction OBJECT IDENTIFIER ::= {acAnalogAction 2} -- **************************************** -- acAnalogFxsLineTest table declaration -- **************************************** acAnalogFxsLineTestTable OBJECT-TYPE SYNTAX SEQUENCE OF AcAnalogFxsLineTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acAnalogFxsAction 1} -- **************************************** -- acAnalogFxsLineTest table entry -- **************************************** acAnalogFxsLineTestEntry OBJECT-TYPE SYNTAX AcAnalogFxsLineTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acAnalogFxsLineTestIndex} ::= {acAnalogFxsLineTestTable 1} -- **************************************** -- acAnalogFxsLineTest TABLE -- **************************************** AcAnalogFxsLineTestEntry ::= SEQUENCE { acAnalogFxsLineTestIndex Unsigned32, acAnalogFxsLineTestActivate INTEGER, acAnalogFxsLineTestHookState INTEGER, acAnalogFxsLineTestRingState INTEGER, acAnalogFxsLineTestPolarityStatus INTEGER, acAnalogFxsLineTestMessageWaitingIndication INTEGER, acAnalogFxsLineTestLineCurrentReading Unsigned32, acAnalogFxsLineTestLineVoltageReading Integer32, acAnalogFxsLineTestAnalogVoltageReading Unsigned32, acAnalogFxsLineTestRingVoltageReading Integer32, acAnalogFxsLineTestLongLineCurrentReading Unsigned32 } acAnalogFxsLineTestIndex OBJECT-TYPE SYNTAX Unsigned32 (0..24) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for table use. AC INI-Param: N/A" ::= {acAnalogFxsLineTestEntry 1} acAnalogFxsLineTestActivate OBJECT-TYPE SYNTAX INTEGER { noTestActivated(0) , runLineTest(1) , lineTestDone(2) , testFailed(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Activate line testing in a FXS analog line according to a given line-index. AC INI-Param: N/A" ::= {acAnalogFxsLineTestEntry 2} acAnalogFxsLineTestHookState OBJECT-TYPE SYNTAX INTEGER { onHookState(1) , offHookState(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The hook state of the analog line. AC INI-Param: N/A" ::= {acAnalogFxsLineTestEntry 3} acAnalogFxsLineTestRingState OBJECT-TYPE SYNTAX INTEGER { offRingState(1) , onRingState(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Line's ring state. AC INI-Param: N/A" ::= {acAnalogFxsLineTestEntry 4} acAnalogFxsLineTestPolarityStatus OBJECT-TYPE SYNTAX INTEGER { normalPolarity(1) , reversePolarity(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Line's reversal-polarity. AC INI-Param: N/A" ::= {acAnalogFxsLineTestEntry 5} acAnalogFxsLineTestMessageWaitingIndication OBJECT-TYPE SYNTAX INTEGER { noWaitingMessage(1) , waitingMessage(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Line's messgae waiting indication state. AC INI-Param: N/A" ::= {acAnalogFxsLineTestEntry 6} acAnalogFxsLineTestLineCurrentReading OBJECT-TYPE SYNTAX Unsigned32 (0..3000) MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The Line current reading in 10ua units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. As of version 6.6 this is an obsolete parameter. AC INI-Param: N/A" ::= {acAnalogFxsLineTestEntry 7} acAnalogFxsLineTestLineVoltageReading OBJECT-TYPE SYNTAX Integer32 (-6000..6000) MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The Line voltage reading in 10mV units. In case of MP124 the Line voltage reading in 1V units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. As of version 6.6 this is an obsolete parameter. AC INI-Param: N/A" ::= {acAnalogFxsLineTestEntry 8} acAnalogFxsLineTestAnalogVoltageReading OBJECT-TYPE SYNTAX Unsigned32 (300..340) MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The current analog voltage reading in 10mV units. his test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. As of version 6.6 this is an obsolete parameter. AC INI-Param: N/A" ::= {acAnalogFxsLineTestEntry 9} acAnalogFxsLineTestRingVoltageReading OBJECT-TYPE SYNTAX Integer32 (-13000..13000) MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The current ring voltage reading in 10mV units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. As of version 6.6 this is an obsolete parameter. AC INI-Param: N/A" ::= {acAnalogFxsLineTestEntry 10} acAnalogFxsLineTestLongLineCurrentReading OBJECT-TYPE SYNTAX Unsigned32 (0..4000) MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The current long line reading in 10ua units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. As of version 6.6 this is an obsolete parameter. AC INI-Param: N/A" ::= {acAnalogFxsLineTestEntry 11} acAnalogCommonAction OBJECT IDENTIFIER ::= {acAnalogAction 3} -- **************************************** -- acAnalogCommonChannel table declaration -- **************************************** acAnalogCommonChannelTable OBJECT-TYPE SYNTAX SEQUENCE OF AcAnalogCommonChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table for common channels operations." ::= {acAnalogCommonAction 1} -- **************************************** -- acAnalogCommonChannel table entry -- **************************************** acAnalogCommonChannelEntry OBJECT-TYPE SYNTAX AcAnalogCommonChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acAnalogCommonChannelIndex} ::= {acAnalogCommonChannelTable 1} -- **************************************** -- acAnalogCommonChannel TABLE -- **************************************** AcAnalogCommonChannelEntry ::= SEQUENCE { acAnalogCommonChannelIndex Unsigned32, acAnalogCommonChannelAction INTEGER } acAnalogCommonChannelIndex OBJECT-TYPE SYNTAX Unsigned32 (0..5000) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for table use, the current channel. AC INI-Param: N/A" ::= {acAnalogCommonChannelEntry 1} acAnalogCommonChannelAction OBJECT-TYPE SYNTAX INTEGER { noAction(0) , reset(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "An action to make on the current channel, The Reset action is for Analog channels only. AC INI-Param: N/A" ::= {acAnalogCommonChannelEntry 2} acAnalogLegs OBJECT IDENTIFIER ::= {acAnalogStatus 21} -- **************************************** -- acAnalogLegs table declaration -- **************************************** acAnalogLegsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcAnalogLegsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acAnalogLegs 1} -- **************************************** -- acAnalogLegs table entry -- **************************************** acAnalogLegsEntry OBJECT-TYPE SYNTAX AcAnalogLegsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acAnalogLegsLegIndex} ::= {acAnalogLegsTable 1} -- **************************************** -- acAnalogLegs TABLE -- **************************************** AcAnalogLegsEntry ::= SEQUENCE { acAnalogLegsLegIndex Unsigned32, acAnalogLegsCallIndex Unsigned32, acAnalogLegsAnalogType INTEGER, acAnalogLegsEchoCanceller INTEGER, acAnalogLegsHighPassFilter INTEGER, acAnalogLegsDTMFDetection INTEGER, acAnalogLegsVoiceVolume Unsigned32, acAnalogLegsInputGain Unsigned32, acAnalogLegsLegName SnmpAdminString } acAnalogLegsLegIndex OBJECT-TYPE SYNTAX Unsigned32 (0..5000) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Decribes The Digital EndPoint In A Call. AC INI-Param: N/A" ::= {acAnalogLegsEntry 1} acAnalogLegsCallIndex OBJECT-TYPE SYNTAX Unsigned32 (0..5000) MAX-ACCESS read-only STATUS current DESCRIPTION "Decribes The Call which The Rtp EndPoint Participant In It. AC INI-Param: N/A" ::= {acAnalogLegsEntry 2} acAnalogLegsAnalogType OBJECT-TYPE SYNTAX INTEGER { fxs(1) , fxo(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describs whether the board is FXS or FXO. AC INI-Param: N/A" ::= {acAnalogLegsEntry 3} acAnalogLegsEchoCanceller OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables or Disables the Echo Canceller. AC INI-Param: N/A" ::= {acAnalogLegsEntry 4} acAnalogLegsHighPassFilter OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables or Disables theHigh Pass Filter. AC INI-Param: N/A" ::= {acAnalogLegsEntry 5} acAnalogLegsDTMFDetection OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables or Disables the DTMF Detection. AC INI-Param: N/A" ::= {acAnalogLegsEntry 6} acAnalogLegsVoiceVolume OBJECT-TYPE SYNTAX Unsigned32 (0..20000) MAX-ACCESS read-only STATUS current DESCRIPTION "Describs the volume of the voice in dB. AC INI-Param: N/A" ::= {acAnalogLegsEntry 7} acAnalogLegsInputGain OBJECT-TYPE SYNTAX Unsigned32 (0..20000) MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the Input Gain on the leg in dB. AC INI-Param: N/A" ::= {acAnalogLegsEntry 8} acAnalogLegsLegName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the Leg Name as in the Control Protocol. AC INI-Param: N/A" ::= {acAnalogLegsEntry 9} END