AC-SYSTEM-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI TAddress, DisplayString, DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC IpAddress FROM RFC1155-SMI RowPointer FROM SNMPv2-TC Unsigned32, Integer32, enterprises FROM SNMPv2-SMI RowStatus FROM SNMPv2-TC SnmpAdminString FROM SNMP-FRAMEWORK-MIB audioCodes, acRegistrations, acGeneric, acProducts,acBoardMibs FROM AUDIOCODES-TYPES-MIB InetAddress, InetAddressType FROM INET-ADDRESS-MIB; acSystem MODULE-IDENTITY LAST-UPDATED "201408200359Z" --Wednesday, August 20 2014 ORGANIZATION "AudioCodes Ltd" CONTACT-INFO "Postal: Support AudioCodes LTD 1 Hayarden Street Airport City Lod, ISRAEL 70151 Tel: 972-3-9764000 Fax: 972-3-9764040 Email: support@audiocodes.com Web: www.audiocodes.com" DESCRIPTION "" ::= {acBoardMibs 10} acSystemConfiguration OBJECT IDENTIFIER ::= {acSystem 1} acSysControl OBJECT IDENTIFIER ::= {acSystemConfiguration 1} acSysControlProtocolType OBJECT-TYPE SYNTAX INTEGER { controlProtocol-None(0) , controlProtocol-MGCP(1) , controlProtocol-MEGACO(2) , controlProtocol-H323(4) , controlProtocol-SIP(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the control protocol type. Choose either: 0 = None 1 = MGCP 2 = MEGACO 4 = H.323 8 = SIP. Access: Offline. AC INI-Param: MGCONTROLPROTOCOLTYPE" ::= {acSysControl 1} acSysControlTrunkingToAnalogFunctionalityProfile OBJECT-TYPE SYNTAX INTEGER { disable(0) , cASAnalog(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the Trunking to Analog Functionality Profile. 0 = Disable 1 = Enable MelCAS/LoopStart/GroundStart to Analog Functionality Refer to the enumerator acTrunkingToAnalogFunctionalityProfile enum for the possible values. Access: Offline. AC INI-Param: TrunkingToAnalogFunctionalityProfile" ::= {acSysControl 2} acSysTDM OBJECT IDENTIFIER ::= {acSystemConfiguration 2} acSysTDMClock OBJECT IDENTIFIER ::= {acSysTDM 1} acSysTDMClockSource OBJECT-TYPE SYNTAX INTEGER { internal(1) , mVIP(3) , network(4) , h110-A(8) , h110-B(9) , netReference1(10) , netReference2(11) , sC-2M(12) , sC-4M(13) , sC-8M(14) , bITS(15) , network-b(16) , aTM-OC3(17) , aTM-OC3-B(18) , aTM-OC12(19) , network-DS3-1(20) , network-DS3-2(21) , network-DS3-3(22) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the clock source on which the board synchronizes. 1 = Local oscillator 3 = MVIP 4 = PSTN Network 8 = H.110A 9 = H.110B 10 = NetRef1 11 = NetRef2 12 = SC2M 13 = SC4M 14 = SC8M 15 = BITS 16 = Network-B 17 = ATM-OC3 18 = ATM-OC3-B 19 = ATM-OC12 20 = Network-DS3-1 21 = Network-DS3-2 22 = Network-DS3-3 Default = 1 TP-1610 = 3 The Paramater is online for TP6310 and TP8410 . For all other boards, the parameter is offline. Access: Online. AC INI-Param: TDMBUSCLOCKSOURCE" ::= {acSysTDMClock 1} acSysTDMClockEnableFallBack OBJECT-TYPE SYNTAX INTEGER { manual(0) , autoNon-Revertive(1) , auto-Revertive(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the auto fallback of the clock. Range: 0 = Manual 1 = Auto Non-Revertive 2 = Auto Revertive. Access: Online. AC INI-Param: TDMBUSENABLEFALLBACK" ::= {acSysTDMClock 2} acSysTDMClockLocalReference OBJECT-TYPE SYNTAX Unsigned32 (0..256) MAX-ACCESS read-write STATUS current DESCRIPTION "When the clock source is set to Network, this parameter selects the Trunk ID to be used as the clock synchronization source of the board. When using H.110/H.100 bus, this parameter also selects the trunk used as the clock source for the NetRef clock generation (in this case, the clock source must not be set to Network. Range = 0 to (MAX_TRUNK _NUM-1). Access: Online. AC INI-Param: TDMBusLocalReference" ::= {acSysTDMClock 3} acSysTDMClockMasterSlaveSelection OBJECT-TYPE SYNTAX INTEGER { acTDMBusSlaveMode(0) , acTDMBusMasterMode(1) , acH110BusSecondaryMasterMode(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Sets SC/MVIP/H.100/H.110 to either: 0 = Slave mode (another board in the system must supply the clock to the TDM bus) or Master mode (the board is the clock source for the TDM bus) or Secondary Master mode (for H100/H110 Bus only). 1 = H110A Master in Master mode 2 = H.110B Master. Access: Online. AC INI-Param: TDMBUSMASTERSLAVESELECTION" ::= {acSysTDMClock 4} acSysTDMClockNetRefSpeed OBJECT-TYPE SYNTAX INTEGER { acTH110BusNetRefSpeed-8khz(0) , acTH110BusNetRefSpeed-1544khz(1) , acTH110BusNetRefSpeed-20488khz(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the NetRef frequency (for both generation and synchronization). 0 = 8 kHz 1 = 1.544 MHz 2 = 2.048 MHz. Access: Online. AC INI-Param: TDMBUSNETREFSPEED" ::= {acSysTDMClock 5} acSysTDMClockAutoFallBackEnable OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables or disables the PSTN trunk auto-fallback feature. Access: Offline. AC INI-Param: TDMBusPSTNAutoClockEnable" ::= {acSysTDMClock 6} acSysTDMClockAutoFallBackRevertingEnable OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/disables the PSTN trunk auto-fallback reverting feature. Access: Offline. AC INI-Param: TDMBusPSTNAutoClockRevertingEnable" ::= {acSysTDMClock 7} acSysTDMClockBitsReference OBJECT-TYPE SYNTAX Unsigned32 (1..2) MAX-ACCESS read-write STATUS current DESCRIPTION "Configures the BITS clock reference when the board source clock is set to BITS and Fallback is set to manual or non-revertive. 1 = REF_1 2 = REF_2. Access: Online. AC INI-Param: TDMBITSClockReference" ::= {acSysTDMClock 8} acSysTDMClockPLLOutOfRange OBJECT-TYPE SYNTAX INTEGER { oor-9-2to12ppm(0) , oor-40to52ppm(1) , oor-100to130ppm(2) , oor-64to83ppm(3) , oor-13-8to18ppm(4) , oor-24-6to32ppm(5) , oor-36-6to47-5ppm(6) , oor-52to67-5ppm(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the valid PPM range outside the Stratum 3 standard. This parameter is only relevant for the TP8410 on the Mediant 3000. This parameter is enabled when bspTimingModuleCfgTimingMode is set to TM_External_MODE(1). One of the following possible values: OOR_9_2to12ppm(0),OOR_40to52ppm(1),OOR_100to130ppm(2),OOR_64to83ppm(3),OOR_13_8to18ppm(4),OOR_24_6to32ppm(5),OOR_36_6to47_5ppm(6),OOR_52to67_5ppm(7). Access: Online. AC INI-Param: PLLOutOfRange" ::= {acSysTDMClock 9} acSysTDMClockFallbackClock OBJECT-TYPE SYNTAX INTEGER { network(4) , h110-A(8) , h110-B(9) , netReference1(10) , netReference2(11) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the fallback clock source on which board synchronizes in the event of clock failure. 4 = PSTN Network 8 = H.110A 9 = H.110B 10 = NetRef1 11 = NetRef2. Access: Online. AC INI-Param: TDMBusFallbackClock" ::= {acSysTDMClock 10} acSysTDMBus OBJECT IDENTIFIER ::= {acSysTDM 2} acSysTDMBusType OBJECT-TYPE SYNTAX INTEGER { mVIP-BUS(0) , sC-BUS(1) , uSE-FRAMERS(2) , qSLAC-BUS(3) , uSE-H110-BUS(4) , uSE-EXT-BUS(5) , aNALOG-BUS(6) , uSE-PSTN-SW-ONLY(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the TDM bus interface to be used (only one TDM bus interface can be enabled at one time although more than one can physically exist on the board). Range: 0 = acMVIP_BUS 1 = acSC_BUS 2 = acFRAMERS 4 = acH100_BUS 5 = EXT TDM 6 = Analog 8 = SW Pstn Default: TP-1610 and TP-2810 = 2 TPM-1100 = 5 TP-260 = 1. Access: Offline. AC INI-Param: TDMBUSTYPE" ::= {acSysTDMBus 1} acSysTDMBusSpeed OBJECT-TYPE SYNTAX INTEGER { acTDMBusSpeed-2Mbps(0) , acTDMBusSpeed-4Mbps(2) , acTDMBusSpeed-8Mbps(3) , acTDMBusSpeed-16Mbps(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the TDM bus speed according to the Bus Type as follows: SC = 0/2/3 H.110/H.100 = 3 MVIP = 0 Where: 0 = 2048 kbps 2 = 4096 kbps 3 = 8192 kbps 4 = 16384 kbps Default: TP-260 = 2 All other boards = 3. Access: Offline. AC INI-Param: TDMBUSSPEED" ::= {acSysTDMBus 2} acSysTDMBusOutputPort OBJECT-TYPE SYNTAX Unsigned32 (0..31) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the SC/MVIP/H.100/H.110 output port to be used for the board's channel #0. All other channels then occupy the next timeslots sequentially. Range: 0 to 15 for SC/MVIP 0 to 31 for H.110. Access: Offline. AC INI-Param: TDMBUSOUTPUTPORT" ::= {acSysTDMBus 3} acSysTDMBusOutputStartingChannel OBJECT-TYPE SYNTAX Unsigned32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the outgoing TDM Timeslot for board's channel #0. The remaining channels are organized sequentially. Access: Offline. AC INI-Param: TDMBUSOUTPUTSTARTINGCHANNEL" ::= {acSysTDMBus 4} acSysPCM OBJECT IDENTIFIER ::= {acSysTDM 3} acSysPCMLawSelect OBJECT-TYPE SYNTAX INTEGER { muLaw(3) , aLaw(1) , automatic(0) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the type of PCM companding law in input/output TDM bus (TDM bus is defined using the TDMBusType parameter). 1 = A-law 3 = Mu-Law. Access: Offline. AC INI-Param: PCMLAWSELECT" ::= {acSysPCM 1} acSysPCMIdlePattern OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the PCM pattern applied to the E1/T1 timeslot (B-channel) when the channel is idle. Default: 0xFF if PCMLawSelect is Mu-Law 0xD5 if PCMLawSelect is A-Law Range = 0x00 to 0xFF. Access: Offline. AC INI-Param: IDLEPCMPATTERN" ::= {acSysPCM 2} acSysPCMIdleABCDPattern OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the ABCD (CAS) pattern to be applied on the signaling bus before it is changed by the user or the PSTN protocol. This is only relevant when using PSTN interface with CAS protocols. Range = 0x0 to 0xF. Access: Offline. AC INI-Param: IDLEABCDPATTERN" ::= {acSysPCM 3} acSysPCMSerialPortAuditIntervalMin OBJECT-TYPE SYNTAX Unsigned32 (0..60) MAX-ACCESS read-write STATUS current DESCRIPTION "Interval timeout in minutes, of the Serial Port audit. In case of 0 value, the audit isn't running. Access: Offline. AC INI-Param: SerialPortAuditIntervalMin" ::= {acSysPCM 4} acSysNetworkConfig OBJECT IDENTIFIER ::= {acSystemConfiguration 3} acSysIP OBJECT IDENTIFIER ::= {acSysNetworkConfig 1} acSysIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Board IP Address. In human readable form. in host byte order e.g. 192.10.1.2 = 0xc00a0102). Users should set the subnet mask to a valid value per the IP address. Access: Online. AC INI-Param: N/A" ::= {acSysIP 1} acSysIPSubNetAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Board SubNet Address. In human readable form. (in host byte order e.g. 255.255.255.0 = 0xffffff00). default =255.255.255.0. Access: Online. AC INI-Param: N/A" ::= {acSysIP 2} acSysIPDefaultGatewayAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Default Gateway Address. Board's Default Gateway IP address. In human readable form. (in host byte order e.g. 192.10.1.255 = 0xc00a01ff). Access: Online. AC INI-Param: N/A" ::= {acSysIP 3} acSysIPDHCPEnable OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/disables DHCP support. 0 = Disable 1 = Enable After the gateway is powered up, it attempts to communicate with a BootP server. If a BootP server does not respond and if DHCP is enabled, the gateway attempts to obtain its IP address and other network parameters from the DHCP server. Note that throughout the DHCP procedure, the BootP/TFTP application must be deactivated. If it isn’t deactivated, the gateway receives a response from the BootP server instead of the DHCP server. For additional information on DHCP, refer to the product documentation. Note: DHCPEnable is a special ‘Hidden’ parameter. Once defined and saved in flash memory, its assigned value doesn’t revert to its default even if the parameter doesn't appear in the INI file. Access: Online. AC INI-Param: DHCPEnable" ::= {acSysIP 4} acSysIPDHCPSpeedFactor OBJECT-TYPE SYNTAX Unsigned32 (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the DHCP renewal speed. When set to 0, the DHCP lease renewal is disabled. Otherwise, the renewal time is divided by this factor. Some DHCP-enabled routers perform better when set to 4. 0 = Disable DHCP 1 = Normal 2 to 10 = Fast. Access: Offline. AC INI-Param: DHCPSpeedFactor" ::= {acSysIP 5} acSysIPDnsPrimaryServerType OBJECT-TYPE SYNTAX INTEGER { ipv4(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the DNS primary server's IP address type. Access: Offline. AC INI-Param: N/A" ::= {acSysIP 6} acSysIPDnsPrimaryServer OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the DNS primary server's IP address. Range = Legal IP address. Access: Offline. AC INI-Param: DNSPriServerIP" ::= {acSysIP 7} acSysIPDnsSecondaryServerType OBJECT-TYPE SYNTAX INTEGER { ipv4(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the DNS secondary server's IP address type. Access: Offline. AC INI-Param: N/A" ::= {acSysIP 8} acSysIPDnsSecondaryServer OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the DNS secondary server's IP address. Range = Legal IP address. Access: Offline. AC INI-Param: DNSSecServerIP" ::= {acSysIP 9} acSysIPDHCPLeaseRenewalEnable OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Enables/disables DHCP renewal support. This paramater will only take effect if DHCPEnable = 0. After the gateway is powered up, it attempts to communicate with a BootP server. If a BootP server does not respond and if DHCP is disabled, the gateway will boot from flash. It will then attempt to communicate with the DHCP server to renew the lease. Note that throughout the DHCP procedure, the BootP/TFTP application must be deactivated. If it isn’t deactivated, the gateway receives a response from the BootP server instead of the DHCP server. For additional information on DHCP, refer to the product documentation. For cases where the booting the board via DHCP is not desirable, but renewing DHCP leasing is. if DHCPEnable = 1, this paramater will not have any effect. Access: Online. AC INI-Param: EnableDHCPLeaseRenewal" ::= {acSysIP 10} acSysIPWanInterfaceName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..38)) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the WAN interface name to be used by VOIP signalling applications. see CLI documentation for interface name formats. Access: Offline. AC INI-Param: WanInterfaceName" ::= {acSysIP 11} acMultipleIP OBJECT IDENTIFIER ::= {acSysIP 30} acMultipleIPEnable OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Enables the multiple IPs feature. 0 = Disable 1 = Enable. Access: Offline. AC INI-Param: EnableMultipleIPs" ::= {acMultipleIP 1} acMultipleIPEnableTPNCPasOAM OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the TPNCP location on the Operation, Administration and Management (OAM) network, when operating in multiple IPs mode. If this parameter is set and the machine is working in multiple IPs mode, TPNCP is located on the OAM network. 0 = TPNCP on Control network 1 = TPNCP on OAM network. Access: Offline. AC INI-Param: EnableTPNCPasOAM" ::= {acMultipleIP 2} acMultipleIPEnableDNSasOAM OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the location of the DNS. If this parameter is set and the machine is functioning in multiple IPs mode, the DNS is located on the OAM network. If not, the DNS is on the control network. 0 = Disable 1 = Enable. Access: Offline. AC INI-Param: EnableDNSasOAM" ::= {acMultipleIP 3} acMultipleIPEnableNTPasOAM OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the location of the Network Time Protocol (NTP). If this parameter is set and the machine is functioning in multiple IPs mode, the NTP is located on the OAM network. If not, the NTP is located on the control network. 0 = Disable 1 = Enable. Access: Offline. AC INI-Param: EnableNTPasOAM" ::= {acMultipleIP 4} acMultipleIPEnableSCTPasControl OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the location of the Stream Control Transmission Protocol (SCTP). If this parameter is set and the machine is functioning in multiple IPs mode, the SCTP is located on the control network. If not, the SCTP is located on the OAM network. 0 = Default 1 = Enable. Access: Offline. AC INI-Param: EnableSCTPasControl" ::= {acMultipleIP 5} acMultipleIPEnableNetwotkSeparation OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables Network Physical Separation. Allows the user to have separate port for each Network. Requires suitable hardware. 0 = Disabled 1 = Enabled. Access: Offline. AC INI-Param: ENABLENETWORKPHYSICALSEPARATION" ::= {acMultipleIP 6} acMultipleIPInterfaceTableAction OBJECT-TYPE SYNTAX INTEGER { done(1) , validateConfiguration(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is an action object. Set this to validateConfiguration(2) when you want the configuration in the acSysInterfaceTable to be validated immediately (as opposed to at reset). done(1) is the default value for any GET on this object. The results of the action should be followed in the syslog. Access: Instant. AC INI-Param: N/A" ::= {acMultipleIP 7} -- **************************************** -- acNetworkIP table declaration -- **************************************** acNetworkIPTable OBJECT-TYPE SYNTAX SEQUENCE OF AcNetworkIPEntry MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "IP control table. Enables to add, remove or configure the device's networks." ::= {acMultipleIP 21} -- **************************************** -- acNetworkIP table entry -- **************************************** acNetworkIPEntry OBJECT-TYPE SYNTAX AcNetworkIPEntry MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "" INDEX {acNetworkIPIndex} ::= {acNetworkIPTable 1} -- **************************************** -- acNetworkIP TABLE -- **************************************** AcNetworkIPEntry ::= SEQUENCE { acNetworkIPIndex INTEGER, acNetworkIPIfIndex Unsigned32, acNetworkIPLocalIPAddress IpAddress, acNetworkIPLocalSubnetMask IpAddress, acNetworkIPLocalDefGW IpAddress, acNetworkIPAdminState INTEGER } acNetworkIPIndex OBJECT-TYPE SYNTAX INTEGER { oam(1) , media(2) , control(3) } MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "The row's index. AC INI-Param: N/A" ::= {acNetworkIPEntry 1} acNetworkIPIfIndex OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The row's index in the IF MIB. The IF MIB is not yet supported and so for now this is the same as the ipCidrRouteIfIndex object. 0 = OAM 1 = Media 2 = Control. AC INI-Param: N/A" ::= {acNetworkIPEntry 2} acNetworkIPLocalIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Sets the IP address of the OAM (Operation, Administration & Management) when operating in multiple IPs mode. Range: Legal IP address Default = 0.0.0.0. Access: Online. AC INI-Param: N/A" ::= {acNetworkIPEntry 3} acNetworkIPLocalSubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Sets the Subnet Mask for the OAM interface, when operating in multiple IPs mode. Range: Legal Subnet Default = 0.0.0.0. Access: Online. AC INI-Param: N/A" ::= {acNetworkIPEntry 4} acNetworkIPLocalDefGW OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Sets the Default gateway for the OAM interface when operating in multiple IPs mode. Range: Legal IP address in subnet Default = 0.0.0.0. Access: Online. AC INI-Param: N/A" ::= {acNetworkIPEntry 5} acNetworkIPAdminState OBJECT-TYPE SYNTAX INTEGER { lock(1) , unLock(2) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Determines if a row is currentely active or not. Lock(1) - the row is in configuration (non active) state. UnLock(2) - row is in active state. Access: Online. AC INI-Param: N/A" ::= {acNetworkIPEntry 6} -- **************************************** -- acSysInterface table declaration -- **************************************** acSysInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Multiple Interfaces' Interface Table" ::= {acMultipleIP 22} -- **************************************** -- acSysInterface table entry -- **************************************** acSysInterfaceEntry OBJECT-TYPE SYNTAX AcSysInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysInterfaceIndex} ::= {acSysInterfaceTable 1} -- **************************************** -- acSysInterface TABLE -- **************************************** AcSysInterfaceEntry ::= SEQUENCE { acSysInterfaceIndex Unsigned32, acSysInterfaceRowStatus RowStatus, acSysInterfaceAction INTEGER, acSysInterfaceActionRes INTEGER, acSysInterfaceApplicationTypes INTEGER, acSysInterfaceMode INTEGER, acSysInterfaceIPAddress SnmpAdminString, acSysInterfacePrefixLength Unsigned32, acSysInterfaceGateway SnmpAdminString, acSysInterfaceVlanID Unsigned32, acSysInterfaceName SnmpAdminString, acSysInterfacePrimaryDNSServerIPAddress SnmpAdminString, acSysInterfaceSecondaryDNSServerIPAddress SnmpAdminString, acSysInterfaceUnderlyingInterface RowPointer } acSysInterfaceIndex OBJECT-TYPE SYNTAX Unsigned32 (0..31) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index Field for line. AC INI-Param: InterfaceTable_Index" ::= {acSysInterfaceEntry 1} acSysInterfaceRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "ROWSTATUS Field for line. AC INI-Param: InterfaceTable_RowStatus" ::= {acSysInterfaceEntry 2} acSysInterfaceAction OBJECT-TYPE SYNTAX INTEGER { none(0) } MAX-ACCESS read-create STATUS current DESCRIPTION "Mangement Field for ACTIONS. AC INI-Param: InterfaceTable_Action" ::= {acSysInterfaceEntry 3} acSysInterfaceActionRes OBJECT-TYPE SYNTAX INTEGER { succeeded(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Mangement Field for ACTIONS RESULT. AC INI-Param: InterfaceTable_ActionRes" ::= {acSysInterfaceEntry 4} acSysInterfaceApplicationTypes OBJECT-TYPE SYNTAX INTEGER { oam(0) , media(1) , control(2) , oamAndMedia(3) , oamAndControl(4) , mediaAndControl(5) , oamAndMediaAndControl(6) , maintenance(99) } MAX-ACCESS read-create STATUS current DESCRIPTION "The type assigned to the interface. Access: Offline. AC INI-Param: InterfaceTable_ApplicationTypes" ::= {acSysInterfaceEntry 5} acSysInterfaceMode OBJECT-TYPE SYNTAX INTEGER { iPv6PrefixManual(3) , iPv6Manual(4) , iPv4Manual(10) } MAX-ACCESS read-create STATUS current DESCRIPTION "Interface configuration mode. Access: Offline. AC INI-Param: InterfaceTable_InterfaceMode" ::= {acSysInterfaceEntry 6} acSysInterfaceIPAddress OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..45)) MAX-ACCESS read-create STATUS current DESCRIPTION "IP Address (can be either IPv4 or IPv6) for this interface. Access: Online. AC INI-Param: InterfaceTable_IPAddress" ::= {acSysInterfaceEntry 7} acSysInterfacePrefixLength OBJECT-TYPE SYNTAX Unsigned32 (0..128) MAX-ACCESS read-create STATUS current DESCRIPTION "The number of ‘1’ bits in this interface’s netmask. Access: Offline. AC INI-Param: InterfaceTable_PrefixLength" ::= {acSysInterfaceEntry 8} acSysInterfaceGateway OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..45)) MAX-ACCESS read-create STATUS current DESCRIPTION "Default Gateway. Filled in one row only. 0 in others. Access: Offline. AC INI-Param: InterfaceTable_Gateway" ::= {acSysInterfaceEntry 9} acSysInterfaceVlanID OBJECT-TYPE SYNTAX Unsigned32 (0..4094) MAX-ACCESS read-create STATUS current DESCRIPTION "VLAN ID of this interface. Access: Offline. AC INI-Param: InterfaceTable_VlanID" ::= {acSysInterfaceEntry 10} acSysInterfaceName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..16)) MAX-ACCESS read-create STATUS current DESCRIPTION "a 16 character string of this interface’s name. Access: Offline. AC INI-Param: InterfaceTable_InterfaceName" ::= {acSysInterfaceEntry 11} acSysInterfacePrimaryDNSServerIPAddress OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..45)) MAX-ACCESS read-create STATUS current DESCRIPTION "Primary DNS server IP address. Access: Online. AC INI-Param: InterfaceTable_PrimaryDNSServerIPAddress" ::= {acSysInterfaceEntry 12} acSysInterfaceSecondaryDNSServerIPAddress OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..45)) MAX-ACCESS read-create STATUS current DESCRIPTION "Secondary DNS server IP address. Access: Online. AC INI-Param: InterfaceTable_SecondaryDNSServerIPAddress" ::= {acSysInterfaceEntry 13} acSysInterfaceUnderlyingInterface OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-create STATUS current DESCRIPTION "Multiple Interfaces' Interface Table. Access: Offline. AC INI-Param: InterfaceTable_UnderlyingInterface" ::= {acSysInterfaceEntry 14} -- **************************************** -- acSysPhysicalPorts table declaration -- **************************************** acSysPhysicalPortsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysPhysicalPortsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Physical Ports Table" ::= {acMultipleIP 23} -- **************************************** -- acSysPhysicalPorts table entry -- **************************************** acSysPhysicalPortsEntry OBJECT-TYPE SYNTAX AcSysPhysicalPortsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysPhysicalPortsIndex} ::= {acSysPhysicalPortsTable 1} -- **************************************** -- acSysPhysicalPorts TABLE -- **************************************** AcSysPhysicalPortsEntry ::= SEQUENCE { acSysPhysicalPortsIndex Unsigned32, acSysPhysicalPortsRowStatus RowStatus, acSysPhysicalPortsAction INTEGER, acSysPhysicalPortsActionRes INTEGER, acSysPhysicalPortsPort SnmpAdminString, acSysPhysicalPortsMode INTEGER, acSysPhysicalPortsNativeVlan Unsigned32, acSysPhysicalPortsSpeedDuplex INTEGER, acSysPhysicalPortsPortDescription SnmpAdminString, acSysPhysicalPortsGroupMember SnmpAdminString, acSysPhysicalPortsGroupStatus SnmpAdminString } acSysPhysicalPortsIndex OBJECT-TYPE SYNTAX Unsigned32 (0..5) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index Field for line. AC INI-Param: PhysicalPortsTable_Index" ::= {acSysPhysicalPortsEntry 1} acSysPhysicalPortsRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "ROWSTATUS Field for line. AC INI-Param: PhysicalPortsTable_RowStatus" ::= {acSysPhysicalPortsEntry 2} acSysPhysicalPortsAction OBJECT-TYPE SYNTAX INTEGER { none(0) } MAX-ACCESS read-create STATUS current DESCRIPTION "Mangement Field for ACTIONS. AC INI-Param: PhysicalPortsTable_Action" ::= {acSysPhysicalPortsEntry 3} acSysPhysicalPortsActionRes OBJECT-TYPE SYNTAX INTEGER { succeeded(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Mangement Field for ACTIONS RESULT. AC INI-Param: PhysicalPortsTable_ActionRes" ::= {acSysPhysicalPortsEntry 4} acSysPhysicalPortsPort OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..17)) MAX-ACCESS read-only STATUS current DESCRIPTION "Physical Ports Table. AC INI-Param: PhysicalPortsTable_Port" ::= {acSysPhysicalPortsEntry 5} acSysPhysicalPortsMode OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Port Enable/Disable. AC INI-Param: PhysicalPortsTable_Mode" ::= {acSysPhysicalPortsEntry 6} acSysPhysicalPortsNativeVlan OBJECT-TYPE SYNTAX Unsigned32 (0..4096) MAX-ACCESS read-create STATUS current DESCRIPTION "Port's Native VID or PVID. Access: Offline. AC INI-Param: PhysicalPortsTable_NativeVlan" ::= {acSysPhysicalPortsEntry 7} acSysPhysicalPortsSpeedDuplex OBJECT-TYPE SYNTAX INTEGER { s10BaseTHalfDuplex(0) , s10BaseTFullDuplex(1) , s100BaseTHalfDuplex(2) , s100BaseTFullDuplex(3) , autoNegotiation(4) , s1000BaseTHalfDuplex(6) , s1000BaseTFullDuplex(7) } MAX-ACCESS read-create STATUS current DESCRIPTION "Port's Speed and Duplex Mode. Access: Offline. AC INI-Param: PhysicalPortsTable_SpeedDuplex" ::= {acSysPhysicalPortsEntry 8} acSysPhysicalPortsPortDescription OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..17)) MAX-ACCESS read-create STATUS current DESCRIPTION "Port's User Description. Access: Offline. AC INI-Param: PhysicalPortsTable_PortDescription" ::= {acSysPhysicalPortsEntry 9} acSysPhysicalPortsGroupMember OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..17)) MAX-ACCESS read-only STATUS current DESCRIPTION "Physical Ports Table. AC INI-Param: PhysicalPortsTable_GroupMember" ::= {acSysPhysicalPortsEntry 10} acSysPhysicalPortsGroupStatus OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..17)) MAX-ACCESS read-only STATUS current DESCRIPTION "Active or Redundant Status. AC INI-Param: PhysicalPortsTable_GroupStatus" ::= {acSysPhysicalPortsEntry 11} -- **************************************** -- acSysEtherGroup table declaration -- **************************************** acSysEtherGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysEtherGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Ether Group Table" ::= {acMultipleIP 24} -- **************************************** -- acSysEtherGroup table entry -- **************************************** acSysEtherGroupEntry OBJECT-TYPE SYNTAX AcSysEtherGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysEtherGroupIndex} ::= {acSysEtherGroupTable 1} -- **************************************** -- acSysEtherGroup TABLE -- **************************************** AcSysEtherGroupEntry ::= SEQUENCE { acSysEtherGroupIndex Unsigned32, acSysEtherGroupRowStatus RowStatus, acSysEtherGroupAction INTEGER, acSysEtherGroupActionRes INTEGER, acSysEtherGroupGroup SnmpAdminString, acSysEtherGroupMode INTEGER, acSysEtherGroupMember1 RowPointer, acSysEtherGroupMember2 RowPointer } acSysEtherGroupIndex OBJECT-TYPE SYNTAX Unsigned32 (0..5) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index Field for line. AC INI-Param: EtherGroupTable_Index" ::= {acSysEtherGroupEntry 1} acSysEtherGroupRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "ROWSTATUS Field for line Static table - only notInService/active supported. AC INI-Param: EtherGroupTable_RowStatus" ::= {acSysEtherGroupEntry 2} acSysEtherGroupAction OBJECT-TYPE SYNTAX INTEGER { none(0) } MAX-ACCESS read-create STATUS current DESCRIPTION "Mangement Field for ACTIONS. AC INI-Param: EtherGroupTable_Action" ::= {acSysEtherGroupEntry 3} acSysEtherGroupActionRes OBJECT-TYPE SYNTAX INTEGER { succeeded(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Mangement Field for ACTIONS RESULT. AC INI-Param: EtherGroupTable_ActionRes" ::= {acSysEtherGroupEntry 4} acSysEtherGroupGroup OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet Group's Name. AC INI-Param: EtherGroupTable_Group" ::= {acSysEtherGroupEntry 5} acSysEtherGroupMode OBJECT-TYPE SYNTAX INTEGER { oneRXoneTX(2) , twoRXoneTX(3) , twoRXtwoTX(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Group Mode of Operation. Access: Offline. AC INI-Param: EtherGroupTable_Mode" ::= {acSysEtherGroupEntry 6} acSysEtherGroupMember1 OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-write STATUS current DESCRIPTION "First Member of the Group. Select the OID corresponding to the one appearing in the Physical Ports table. The OID should be 1.3.6.1.4.1.5003.9.10.10.1.3.1.30.23.1.5. acSysPhysicalPortsPort. Access: Offline. AC INI-Param: EtherGroupTable_Member1" ::= {acSysEtherGroupEntry 7} acSysEtherGroupMember2 OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-write STATUS current DESCRIPTION "Second Member of the Group. Select the OID corresponding to the one appearing in the Physical Ports table. The OID should be 1.3.6.1.4.1.5003.9.10.10.1.3.1.30.23.1.5. acSysPhysicalPortsPort. Access: Offline. AC INI-Param: EtherGroupTable_Member2" ::= {acSysEtherGroupEntry 8} acSyslog OBJECT IDENTIFIER ::= {acSysNetworkConfig 2} acSyslogServerIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the IP address in dotted format notation. e.g., 192.10.1.255 Range = Legal IP address. Access: Online. AC INI-Param: SYSLOGSERVERIP" ::= {acSyslog 1} acSyslogEnable OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable SysLog protocol log. Access: Online. AC INI-Param: ENABLESYSLOG" ::= {acSyslog 2} acSyslogAcSyslogServerPortNumber OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the Port number of the Syslog Server. Range = Legal Port Number. Access: Online. AC INI-Param: SyslogServerPort" ::= {acSyslog 3} acSyslogFacility OBJECT-TYPE SYNTAX Unsigned32 (16..23) MAX-ACCESS read-write STATUS current DESCRIPTION "parameter to determine the facility number at syslog messages. can be: 16 = local use 0 (local0) 17 = local use 1 (local1) .. 23 = local use 0 (local7). Access: Online. AC INI-Param: SyslogFacility" ::= {acSyslog 4} acSysNTP OBJECT IDENTIFIER ::= {acSysNetworkConfig 3} acSysNTPServerIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is used to define the NTP server's IP address. Range = Legal IP address. Access: Instant. AC INI-Param: NTPServerIP" ::= {acSysNTP 1} acSysNTPUtcOffset OBJECT-TYPE SYNTAX Integer32 (-43200..43200) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is used to define the NTP time to offset, in seconds. Default = 0 Range = -43200 to +43200 seconds. Access: Instant. AC INI-Param: NTPServerUTCOffset" ::= {acSysNTP 2} acSysNTPUpdateInterval OBJECT-TYPE SYNTAX Unsigned32 (1..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the NTP update interval, in seconds. It's inadvisable to set it exceeding 1 month (2592000 seconds). Range = 0 to 2592000 seconds Default = 86400 seconds. Access: Instant. AC INI-Param: NTPUpdateInterval" ::= {acSysNTP 3} acSysNTPSecondaryServerIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the NTP Secondary Server IP address. Access: Instant. AC INI-Param: NTPSecondaryServerIP" ::= {acSysNTP 4} acSysDayLightSavingTime OBJECT IDENTIFIER ::= {acSysNTP 21} acSysDayLightSavingTimeMode OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines whether to enable the time ajustment to day light saving time while update time from NTP server. Access: Instant. AC INI-Param: DayLightSavingTimeEnable" ::= {acSysDayLightSavingTime 1} acSysDayLightSavingTimeOffset OBJECT-TYPE SYNTAX Unsigned32 (0..120) MAX-ACCESS read-write STATUS current DESCRIPTION "when DayLightSavingTimeEnable is Enable, this parametes determine the fix size in minutes: 0-120. Access: Instant. AC INI-Param: DayLightSavingTimeOffset" ::= {acSysDayLightSavingTime 2} acSysDayLightSavingTimeStart OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the date and time of starting day light time in current year. 2 Possible Formats: 1. (Day of Year) mo:dd:hh:mm . 2. (Day of Month) mo:wday/week:hh:mm where week of month is 01-04, or 05 for specifying last week of the month, and wday is one of the Week Days: SUN, MON, TUE, WED, THU, FRI, SAT. Access: Instant. AC INI-Param: DayLightSavingTimeStart" ::= {acSysDayLightSavingTime 3} acSysDayLightSavingTimeEnd OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the date and time of ending day light time in current year. 2 Possible Formats: 1. (Day of Year) mo:dd:hh:mm . 2. (Day of Month) mo:wday/week:hh:mm where week of month is 01-04, or 05 for specifying last week of the month, and wday is one of the Week Days: SUN, MON, TUE, WED, THU, FRI, SAT. Access: Instant. AC INI-Param: DayLightSavingTimeEnd" ::= {acSysDayLightSavingTime 4} acSysWEB OBJECT IDENTIFIER ::= {acSysNetworkConfig 4} acSysWEBConfigDisable OBJECT-TYPE SYNTAX INTEGER { enable(0) , disable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables or disables Web Configuration. 0 = Read & Write mode (default) 1 = Read Only mode. Access: Offline. AC INI-Param: DISABLEWEBCONFIG" ::= {acSysWEB 1} acSysWEBHTTPSOnly OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Use this parameter to allow only HTTPS connections (force security). When set to 1, unencrypted HTTP (normally, port 80) is blocked. Access: Offline. AC INI-Param: HTTPSOnly" ::= {acSysWEB 2} acSysWEBHTTPSPort OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Determine the local Secure HTTPS port of the device. The default port is 443. Range = 1-65535 (other restrictions may apply in this range). Access: Offline. AC INI-Param: HTTPSPORT" ::= {acSysWEB 3} acSysWEBWebUseRadiusLogin OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Uses the RADIUS (Remote Authentication Dial-In User Server/Service) for Web interface authentication. Make sure that ENABLERADIUS is on. Use of this parameter without HTTPSONLY = 1 is not recommended. Access: Instant. AC INI-Param: WEBRADIUSLOGIN" ::= {acSysWEB 4} acSysWEBHTTPSCipherString OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..200)) MAX-ACCESS read-write STATUS current DESCRIPTION "Requires client certificates for HTTPS connection. The client certificate must be preloaded on the gateway, and its matching private key must be installed on the managing computer. Time and date must be correctly set on the gateway, for the client certificate to be verified. Access: Offline. AC INI-Param: HTTPSCipherString" ::= {acSysWEB 5} acSysWEBDenyAuthenticationTimer OBJECT-TYPE SYNTAX Unsigned32 (0..86400) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the time the next authentication attempt from the last authentication faild IP should be denied. The range can be any value from 0 - 86400 in seconds. Access: Online. AC INI-Param: DenyAuthenticationTimer " ::= {acSysWEB 6} acSysWEBWanHttpPort OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Determines the WAN HTTP port of the device. If set to 0, WAN HTTP access will not be possible. Range = 0 to 65535 (other restrictions may apply in this range). Access: Offline. AC INI-Param: WanMgmtHttpPort" ::= {acSysWEB 7} acSysWEBWanHttpsPort OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Determines the WAN HTTPS port of the device. If set to 0, WAN HTTPS access will not be possible. Range = 0 to 65535 (other restrictions may apply in this range). Access: Offline. AC INI-Param: WanMgmtHttpsPort" ::= {acSysWEB 8} acSysWEBAllowWanHttp OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables or disables WAN access to the management interface via HTTP. Access: Offline. AC INI-Param: AllowWanHttp" ::= {acSysWEB 9} acSysWEBAllowWanHttps OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables or disables WAN access to the management interface via HTTPS. Access: Offline. AC INI-Param: AllowWanHttps" ::= {acSysWEB 10} -- **************************************** -- acSysWEBACL table declaration -- **************************************** acSysWEBACLTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysWEBACLEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Access control list for the WEB." ::= {acSysWEB 21} -- **************************************** -- acSysWEBACL table entry -- **************************************** acSysWEBACLEntry OBJECT-TYPE SYNTAX AcSysWEBACLEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysWEBACLIndex} ::= {acSysWEBACLTable 1} -- **************************************** -- acSysWEBACL TABLE -- **************************************** AcSysWEBACLEntry ::= SEQUENCE { acSysWEBACLIndex Unsigned32, acSysWEBACLIP IpAddress } acSysWEBACLIndex OBJECT-TYPE SYNTAX Unsigned32 (0..9) MAX-ACCESS read-only STATUS current DESCRIPTION "WEB ACL (Access Control List) index. AC INI-Param: N/A" ::= {acSysWEBACLEntry 1} acSysWEBACLIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Allows IP addresses to connect to the Web interface. Set to zeroes to allow all IP addresses. Range: Valid IP address . Access: Instant. AC INI-Param: WEBACCESSLIST" ::= {acSysWEBACLEntry 2} acSysWEBAccess OBJECT IDENTIFIER ::= {acSysNetworkConfig 5} -- **************************************** -- acSysWEBAccess table declaration -- **************************************** acSysWEBAccessTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysWEBAccessEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acSysWEBAccess 1} -- **************************************** -- acSysWEBAccess table entry -- **************************************** acSysWEBAccessEntry OBJECT-TYPE SYNTAX AcSysWEBAccessEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysWEBAccessIndex} ::= {acSysWEBAccessTable 1} -- **************************************** -- acSysWEBAccess TABLE -- **************************************** AcSysWEBAccessEntry ::= SEQUENCE { acSysWEBAccessRowStatus Unsigned32, acSysWEBAccessAction Unsigned32, acSysWEBAccessActionResult Unsigned32, acSysWEBAccessIndex INTEGER, acSysWEBAccessUserName SnmpAdminString, acSysWEBAccessUserCode SnmpAdminString, acSysWEBAccessWebAuthMode INTEGER } acSysWEBAccessRowStatus OBJECT-TYPE SYNTAX Unsigned32 (1..1) MAX-ACCESS read-write STATUS current DESCRIPTION "WEB Basic row-status. AC INI-Param: WEBAccessRowStatus" ::= {acSysWEBAccessEntry 1} acSysWEBAccessAction OBJECT-TYPE SYNTAX Unsigned32 (0..0) MAX-ACCESS read-create STATUS current DESCRIPTION "WEB Access action. AC INI-Param: WEBAccessAction" ::= {acSysWEBAccessEntry 2} acSysWEBAccessActionResult OBJECT-TYPE SYNTAX Unsigned32 (0..0) MAX-ACCESS read-only STATUS current DESCRIPTION "WEB Access action result. AC INI-Param: N/A" ::= {acSysWEBAccessEntry 3} acSysWEBAccessIndex OBJECT-TYPE SYNTAX INTEGER { administrator(0) , monitoringLevel(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "WEB Access index. AC INI-Param: N/A" ::= {acSysWEBAccessEntry 4} acSysWEBAccessUserName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..60)) MAX-ACCESS read-create STATUS current DESCRIPTION "WEB Basic user name. Range = String[26]. Access: Instant. AC INI-Param: WEBAccessUserName " ::= {acSysWEBAccessEntry 5} acSysWEBAccessUserCode OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..60)) MAX-ACCESS read-create STATUS current DESCRIPTION "WEB Basic userAccess. Access: Instant. AC INI-Param: WEBAccessUserCode " ::= {acSysWEBAccessEntry 6} acSysWEBAccessWebAuthMode OBJECT-TYPE SYNTAX INTEGER { basicMode(0) , digestModeWhenPossible(1) , digestModeHTTPOnly(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Selects HTTP basic (clear text) or digest (MD5) authentication for the web interface. When set to 0, basic authentication (clear text) will be used. When set to 1, digest authentication (MD5) will be used. When set to 2, digest authentication (MD5) will be used for HTTP, while basic authentication will be used for HTTPS. Note that turning on RADIUS login forces basic authentication. Access: Instant. AC INI-Param: WebAuthMode" ::= {acSysWEBAccessEntry 7} acSysNATTraversal OBJECT IDENTIFIER ::= {acSysNetworkConfig 6} acSysTelnet OBJECT IDENTIFIER ::= {acSysNetworkConfig 7} acSysTelnetServerEnable OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) , ssl(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables or disables the embedded Telnet server. Telnet is disabled by default for security reasons. 0 = Disable 1= Enable 2 = SSL mode (if available - requires an SSL-aware Telnet client software) SSL mode is not available on the MP-108 / MP-124 media gateways. Access: Instant. AC INI-Param: TelnetServerEnable" ::= {acSysTelnet 1} acSysTelnetServerPort OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the port number for the embedded Telnet server. Range = Valid port number. Access: Online. AC INI-Param: TELNETSERVERPORT" ::= {acSysTelnet 2} acSysTelnetServerIdleDisconnect OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is used to set the timeout for disconnection of an idle Telnet session (minutes). When set to zero, idle sessions are not disconnected. Range: Any number. Access: Offline. AC INI-Param: TelnetServerIdleDisconnect" ::= {acSysTelnet 3} acSysTelnetSSHServerPort OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the port number for the embedded SSH server. Range = Valid port number. Access: Online. AC INI-Param: SSHServerPort" ::= {acSysTelnet 4} acSysTelnetSSHServerEnable OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables or disables the embedded SSH server. 0 = Disable 1= Enable . Access: Online. AC INI-Param: SSHServerEnable" ::= {acSysTelnet 5} acSysTelnetSSHAdminKey OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..510)) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter holds an RSA public key for strong authentication to the SSH interface (if enabled). The value should be a base64-encoded string see the Security appendix for additional information. Access: Instant. AC INI-Param: SSHAdminKey" ::= {acSysTelnet 6} acSysTelnetSSHRequirePublicKey OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables or disables RSA public keys in SSH. When set to 0, RSA public keys are optional (if SSHAdminKey is set). When set to 1, RSA public keys are mandatory. Access: Instant. AC INI-Param: SSHRequirePublicKey" ::= {acSysTelnet 7} acSysTelnetServerWanPort OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Determines the WAN Telnet port of the device. If set to 0, WAN Telnet access will not be possible. Range = 0 to 65535 (other restrictions may apply in this range). Access: Offline. AC INI-Param: WanMgmtTelnetPort" ::= {acSysTelnet 8} acSysTelnetWanSSHServerPort OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Determines the WAN Telnet port of the device. If set to 0, WAN Telnet access will not be possible. Range = 0 to 65535 (other restrictions may apply in this range). Access: Offline. AC INI-Param: WanMgmtSSHPort" ::= {acSysTelnet 9} acSysTelnetSSHMaxSessions OBJECT-TYPE SYNTAX Unsigned32 (1..2) MAX-ACCESS read-write STATUS current DESCRIPTION "Configure maximum allowed number of SSH sessions. Access: Online. AC INI-Param: SSHMaxSessions" ::= {acSysTelnet 10} acSysTelnetSSHMaxPayloadSize OBJECT-TYPE SYNTAX Unsigned32 (550..32768) MAX-ACCESS read-write STATUS current DESCRIPTION "Configure maximum uncompressed payload size for SSH packets, in bytes. Access: Online. AC INI-Param: SSHMaxPayloadSize" ::= {acSysTelnet 11} acSysTelnetSSHMaxBinaryPacketSize OBJECT-TYPE SYNTAX Unsigned32 (582..35000) MAX-ACCESS read-write STATUS current DESCRIPTION "Configure maximum packet size for SSH packets, in bytes. Access: Online. AC INI-Param: SSHMaxBinaryPacketSize" ::= {acSysTelnet 12} acSysTelnetAllowWanTelnet OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables or disables WAN access to the management interface via Telnet. Access: Offline. AC INI-Param: AllowWanTelnet" ::= {acSysTelnet 13} acSysTelnetAllowWanSSH OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables or disables WAN access to the management interface via SSH. Access: Offline. AC INI-Param: AllowWanSSH" ::= {acSysTelnet 14} acSysHTTPClient OBJECT IDENTIFIER ::= {acSysNetworkConfig 8} acSysHTTPClientAutoUpdatePredefinedTime OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..6)) MAX-ACCESS read-write STATUS current DESCRIPTION "Schedules an automatic update to a predefined time of the day. The range is 'HH:MM' (24-hour format). For example: 20:18 . Access: Online. AC INI-Param: AutoUpdatePredefinedTime" ::= {acSysHTTPClient 1} acSysHTTPClientAutoUpdateFrequency OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the number of minutes the gateway waits between automatic updates. The default value is 0 (the update at fixed intervals mechanism is disabled). Range: Any number . Access: Online. AC INI-Param: AutoUpdateFrequency" ::= {acSysHTTPClient 2} acSysHTTPClientAutoUpdateCmpFile OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables / disables the automatic update mechanism for the cmp file. 0 = The automatic update mechanism doesn't apply to the cmp file (default). 1 = The automatic update mechanism includes the cmp file. Access: Online. AC INI-Param: AutoUpdateCmpFile" ::= {acSysHTTPClient 3} acSysHTTPClientCmpFileURL OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter provides a link to a software image (CMP file) to be downloaded from a remote server. . Access: Offline. AC INI-Param: CmpFileURL" ::= {acSysHTTPClient 4} acSysHTTPClientIniFileURL OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter provides a link to an ini file to be downloaded from a remote server. . Access: Offline. AC INI-Param: IniFileURL" ::= {acSysHTTPClient 5} acSysHTTPClientIniFileTemplateURL OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "Provides a link to an ini file to be downloaded from a remote server, in addition to IniFileUrl. Range = http://server_name/file, https://server_name/file. Access: Offline. AC INI-Param: IniFileTemplateUrl" ::= {acSysHTTPClient 6} acSysHTTPClientCPTFileURL OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "Provides a link to a Call Progress Tones (CPT) file to be downloaded from a remote server. Range = http://server_name/file, https://server_name/file. Access: Offline. AC INI-Param: CptFileUrl" ::= {acSysHTTPClient 7} acSysHTTPClientVPFileURL OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "Provides a link to a Voice Prompts file to be downloaded from a remote server. Range = http://server_name/file, https://server_name/file. Access: Online. AC INI-Param: VpFileUrl" ::= {acSysHTTPClient 8} acSysHTTPClientPRTFileURL OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "Provides a link to a prerecorded tones dat file, to be downloaded from a remote server. Range = http://server_name/file, https://server_name/file. Access: Online. AC INI-Param: PrtFileUrl" ::= {acSysHTTPClient 9} acSysHTTPClientFXSCoeffFileURL OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Provides a link to an FXS coefficients file, to be downloaded from a remote server. Range = http://server_name/file, https://server_name/file. Access: Instant. AC INI-Param: FXSCoeffFileUrl" ::= {acSysHTTPClient 10} acSysHTTPClientFXOCoeffFileURL OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Provides a link to an FXO coefficients file, to be downloaded from a remote server. Range = http://server_name/file, https://server_name/file. Access: Instant. AC INI-Param: FXOCoeffFileUrl" ::= {acSysHTTPClient 11} acSysHTTPClientCASFileURL OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "Provides a link to a Channel Associated Signaling (CAS) file to be downloaded from a remote server. Range = http://server_name/file, https://server_name/file. Access: Online. AC INI-Param: CasFileUrl" ::= {acSysHTTPClient 12} acSysHTTPClientXMLFileUrl OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "Provides a link to an XML segments file, to be downloaded from a remote server. See the chapter 'Automatic Update Facility' for supported URL options. Access: Online. AC INI-Param: APSSegmentsFileUrl " ::= {acSysHTTPClient 13} acSysHTTPClientCoderTableFileUrl OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "Provides a link to a coder table (CTBL) file that is to be downloaded from a remote server. . Access: Online. AC INI-Param: CoderTableFileUrl" ::= {acSysHTTPClient 14} acSysHTTPClientUserInfoFileURL OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "Provides a link to the user information file, to be downloaded using Automatic Update. Relevant only for H323 or SIP controlled devices. Access: Online. AC INI-Param: UserInfoFileUrl" ::= {acSysHTTPClient 15} acSysHTTPClientDialPlanFileURL OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "URL for downloading a Dial Plan file using the Automatic Update facility. Access: Online. AC INI-Param: DialPlanFileUrl" ::= {acSysHTTPClient 16} acSysHTTPClientTLSPkeyFileUrl OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "URL for downloading a TLS private key file using the Automatic Update facility. Access: Offline. AC INI-Param: TLSPkeyFileUrl" ::= {acSysHTTPClient 17} acSysHTTPClientTLSCertFileUrl OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "URL for downloading a TLS certificate file using the Automatic Update facility. Access: Offline. AC INI-Param: TLSCertFileUrl" ::= {acSysHTTPClient 18} acSysHTTPClientTLSRootFileUrl OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "URL for downloading a TLS trusted root certificate file using the Automatic Update facility. Access: Offline. AC INI-Param: TLSRootFileUrl" ::= {acSysHTTPClient 19} acSysHTTPClientWebLogoFileUrl OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "URL for downloading a logo file for the web interface using the Automatic Update facility. Access: Online. AC INI-Param: WebLogoFileUrl" ::= {acSysHTTPClient 20} acSysHTTPClientVideoFontFileURL OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the URL for downloading a logo file for the web interface using the Automatic Update facility. Access: Online. AC INI-Param: VideoFontFileUrl" ::= {acSysHTTPClient 21} acSysHTTPClientV5PortConfFileURL OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "Provides a link to a software (V5PortConfiguration file) to be downloaded from a remote server. Access: Online. AC INI-Param: V5PortConfigurationFileURL" ::= {acSysHTTPClient 22} acSysHTTPClientDataConfigurationFileUrl OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "Provides a link to a data configuration file to be downloaded from a remote server using the Automatic Update facility. Access: Offline. AC INI-Param: RGCONFFILEURL" ::= {acSysHTTPClient 23} acSysHTTPClientAmdSensitivityFileUrl OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "Provides a link to the AMD Sensitivity file to be downloaded from a remote server. Access: Online. AC INI-Param: AmdSensitivityFileUrl" ::= {acSysHTTPClient 24} acSysSNMP OBJECT IDENTIFIER ::= {acSysNetworkConfig 9} acSysSNMPKeepAliveTrapPort OBJECT-TYPE SYNTAX Unsigned32 (0..65334) MAX-ACCESS read-write STATUS current DESCRIPTION "The port to which the keep alive traps are sent to. Access: Instant. AC INI-Param: KeepAliveTrapPort" ::= {acSysSNMP 1} acSysSNMPEmsColdStrartIndication OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "EMS object to be used as indication to the device's state in the 'eyes' of the EMS. Default - 0. Access: Instant. AC INI-Param: N/A" ::= {acSysSNMP 2} acSysSNMPWanPort OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "This parameter specifies the WAN port number for SNMP requests and responses. If set to 0, WAN access to SNMP is disabled. Range = 0 to 65535. Access: Offline. AC INI-Param: WanMgmtSnmpPort" ::= {acSysSNMP 3} acSysSNMPAllowWanSnmp OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables or disables WAN access to the management interface via SNMP. Access: Offline. AC INI-Param: AllowWanSnmp" ::= {acSysSNMP 4} acSysVLAN OBJECT IDENTIFIER ::= {acSysNetworkConfig 10} acSysVLANOamVlanId OBJECT-TYPE SYNTAX Unsigned32 (1..4094) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Sets the OAMP (Operation, Administration, Management and Provisioning) VLAN identifier. Range: 1 to 4094. Access: Online. AC INI-Param: VLANOAMVLANID" ::= {acSysVLAN 1} acSysVLANControlVlanId OBJECT-TYPE SYNTAX Unsigned32 (1..4094) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Sets the control VLAN identifier. Range: 1 to 4094. Access: Online. AC INI-Param: VLANCONTROLVLANID" ::= {acSysVLAN 2} acSysVLANMediaVlanId OBJECT-TYPE SYNTAX Unsigned32 (1..4094) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Sets the media VLAN identifier. Range: 1 to 4094. Access: Online. AC INI-Param: VLANMEDIAVLANID" ::= {acSysVLAN 3} acSysVLANNetworkServiceClassPriority OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This parameter is used to set the priority for Network service class content. Range = 0 to 7 Default = 7. Access: Online. AC INI-Param: VLANNETWORKSERVICECLASSPRIORITY" ::= {acSysVLAN 4} acSysVLANPremiumServiceClassMediaPriority OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Sets the priority for the Premium service class content and media traffic. Range = 0 to 7 Default = 6. Access: Online. AC INI-Param: VLANPREMIUMSERVICECLASSMEDIAPRIORITY" ::= {acSysVLAN 5} acSysVLANGoldServiceClassPriority OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Sets the priority for the Gold service class content. Range = 0 to 7 Default = 4. Access: Online. AC INI-Param: VLANGOLDSERVICECLASSPRIORITY" ::= {acSysVLAN 6} acSysVLANBronzeServiceClassPriority OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Sets the priority for the Bronze service class content. Range = 0 to 7 Default = 2. Access: Online. AC INI-Param: VLANBRONZESERVICECLASSPRIORITY" ::= {acSysVLAN 7} acSysVLANPremiumServiceClassControlPriority OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Sets the priority for the Premium service class content and control traffic. Range = 0 to 7 Default = 6. Access: Online. AC INI-Param: VLANPREMIUMSERVICECLASSCONTROLPRIORITY" ::= {acSysVLAN 8} acSysVLANNetworkServiceClassDiffServ OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is used to set the DiffServ for Network service class content. Range = 0 to 63 Default = 48. Access: Online. AC INI-Param: NETWORKSERVICECLASSDIFFSERV" ::= {acSysVLAN 9} acSysVLANPremiumServiceClassMediaDiffServ OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is used to set the DiffServ for Premium service class content and media traffic. Range = 0 to 63. Access: Online. AC INI-Param: PREMIUMSERVICECLASSMEDIADIFFSERV" ::= {acSysVLAN 10} acSysVLANPremiumServiceClassControlDiffServ OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the DiffServ for the Premium service class content and control traffic. Range: 0 to 63. Access: Online. AC INI-Param: PREMIUMSERVICECLASSCONTROLDIFFSERV" ::= {acSysVLAN 11} acSysVLANGoldServiceClassDiffServ OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the DiffServ for the Gold service class content. Range = 0 to 63 Default = 26. Access: Online. AC INI-Param: GOLDSERVICECLASSDIFFSERV" ::= {acSysVLAN 12} acSysVLANBronzeServiceClassDiffServ OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the DiffServ for the Bronze service class content. Range = 0 to 63 Default = 10. Access: Online. AC INI-Param: BRONZESERVICECLASSDIFFSERV" ::= {acSysVLAN 13} acSysVLANVlanNativeVlanId OBJECT-TYPE SYNTAX Unsigned32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the native VLAN identifier. Access: Online. AC INI-Param: VLANNATIVEVLANID" ::= {acSysVLAN 14} acSysVLANMode OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the VLAN functionality. 0 = Disable 1 = Enable. Access: Offline. AC INI-Param: VLANMODE" ::= {acSysVLAN 15} -- **************************************** -- acSysVlanMap table declaration -- **************************************** acSysVlanMapTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysVlanMapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acSysVLAN 21} -- **************************************** -- acSysVlanMap table entry -- **************************************** acSysVlanMapEntry OBJECT-TYPE SYNTAX AcSysVlanMapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysVlanMapIndex} ::= {acSysVlanMapTable 1} -- **************************************** -- acSysVlanMap TABLE -- **************************************** AcSysVlanMapEntry ::= SEQUENCE { acSysVlanMapIndex Unsigned32, acSysVlanMapRowStatus RowStatus, acSysVlanMapAction INTEGER, acSysVlanMapActionRes INTEGER, acSysVlanMapDiffServ Unsigned32, acSysVlanMapVlanPriority Unsigned32 } acSysVlanMapIndex OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index Field for line. Internal parameter. AC INI-Param: DiffServToVlanPriority_Index" ::= {acSysVlanMapEntry 1} acSysVlanMapRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "ROWSTATUS field for line. Internal parameter. AC INI-Param: N/A" ::= {acSysVlanMapEntry 2} acSysVlanMapAction OBJECT-TYPE SYNTAX INTEGER { none(0) } MAX-ACCESS read-create STATUS current DESCRIPTION "Mangement Field for ACTIONS. Internal parameter. AC INI-Param: N/A" ::= {acSysVlanMapEntry 3} acSysVlanMapActionRes OBJECT-TYPE SYNTAX INTEGER { succeeded(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Mangement Field for ACTIONS RESULT. Internal parameter. AC INI-Param: N/A" ::= {acSysVlanMapEntry 4} acSysVlanMapDiffServ OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-create STATUS current DESCRIPTION "Mapping of DiffServ (DSCP) to Vlan Priorities (IEEE 802.1p). Access: Online. AC INI-Param: DiffServToVlanPriority_DiffServ" ::= {acSysVlanMapEntry 5} acSysVlanMapVlanPriority OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-create STATUS current DESCRIPTION "Mapping of DiffServ (DSCP) to Vlan Priorities (IEEE 802.1p). Access: Online. AC INI-Param: DiffServToVlanPriority_VlanPriority" ::= {acSysVlanMapEntry 6} acSysSCTP OBJECT IDENTIFIER ::= {acSysNetworkConfig 11} acSysSCTPHeartBeatInterval OBJECT-TYPE SYNTAX Unsigned32 (0..3600) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the SCTP heartbeat interval. Range: 1 to 3600. Access: Offline. AC INI-Param: SCTPHBInterval" ::= {acSysSCTP 1} acSysSCTPT4SACKTimer OBJECT-TYPE SYNTAX Unsigned32 (1..5) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the SCTP T4 SACK timer interval. Range: 1 to 5. Access: Offline. AC INI-Param: SCTPT4SAckTimer" ::= {acSysSCTP 2} acSysSCTPCheckSumMethod OBJECT-TYPE SYNTAX INTEGER { adler(0) , crc(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Stream Control Transmission Protocol (SCTP) uses a checksum mechanism in order to authenticate packets on both sides (the receiving side and the transmitting side). Presently, two checksum mechanisms are available: 0 = adler32 checksum mechanism 1 = crc32c checksum mechanism (improved mechanism). Access: Offline. AC INI-Param: SCTPChecksumMethod" ::= {acSysSCTP 3} acSysSCTPHostName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "When this parameter is set to any value other than an empty string, SCTP (Stream Control Transmission Protocol) uses the value as the value of the FQDN (Fully Qualified Domain Name) parameter attached to the INIT chunk. In this case, the FQDN parameter replaces any IP address parameters in the INIT chunk. This feature enables overcoming NAT problems where the original IP addresses belonging to the endpoint supports are converted into pseudo addresses. When this parameter is not set (default), the INIT chunk is sent without any FQDN parameter. Range = String[42]. Access: Offline. AC INI-Param: SCTPHOSTNAME" ::= {acSysSCTP 4} acSysSCTPAssociationsNum OBJECT-TYPE SYNTAX Unsigned32 (1..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the maximum number of Stream Control Transmission Protocol (SCTP) associations that can be opened. Range: 1 to 8. Access: Offline. AC INI-Param: SCTPAssociationsNum" ::= {acSysSCTP 5} acSysEthernetPort OBJECT IDENTIFIER ::= {acSysNetworkConfig 12} acSysEthernetPortPhyConfiguration OBJECT-TYPE SYNTAX INTEGER { halfDuplex10BaseT(0) , fullDuplex10BaseT(1) , halfDuplex100BaseT(2) , fullDuplex100BaseT(3) , autoNegotiate(4) , fullDuplex1000BaseT(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the Ethernet connection mode type. Auto-negotiate falls back to Half-Duplex mode (HD) when the opposite port is not in Auto-negotiate mode. The speed (10 Base-T or 100 Base-TX) in this mode is always configured correctly. 0 = 10 Base-T half-duplex 1 = 10 Base-T full-duplex 2 = 100 Base-TX half-duplex 3 = 100 Base-TX full-duplex 4 = Auto-negotiate. Access: Offline. AC INI-Param: EthernetPhyConfiguration" ::= {acSysEthernetPort 1} acSysPOE OBJECT IDENTIFIER ::= {acSysEthernetPort 21} -- **************************************** -- acSysPOE table declaration -- **************************************** acSysPOETable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysPOEEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acSysPOE 1} -- **************************************** -- acSysPOE table entry -- **************************************** acSysPOEEntry OBJECT-TYPE SYNTAX AcSysPOEEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysPOEIndex} ::= {acSysPOETable 1} -- **************************************** -- acSysPOE TABLE -- **************************************** AcSysPOEEntry ::= SEQUENCE { acSysPOEIndex Unsigned32, acSysPOERowStatus RowStatus, acSysPOEAction INTEGER, acSysPOEActionRes INTEGER, acSysPOEPortEnable INTEGER, acSysPOEPortPower Unsigned32, acSysPOEPortATEnable INTEGER } acSysPOEIndex OBJECT-TYPE SYNTAX Unsigned32 (0..11) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameter is used for the Power Over Ethenet (PoE) Index Field for line. Internal parameter. AC INI-Param: POETable_Index" ::= {acSysPOEEntry 1} acSysPOERowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Power Over Ethenet (PoE) ROWSTATUS field for line. Internal parameter. Access: Offline. AC INI-Param: POETable_RowStatus" ::= {acSysPOEEntry 2} acSysPOEAction OBJECT-TYPE SYNTAX INTEGER { none(0) } MAX-ACCESS read-create STATUS current DESCRIPTION "Power Over Ethenet (PoE) Mangement Field for ACTIONS. Internal parameter. Access: Offline. AC INI-Param: POETable_Action" ::= {acSysPOEEntry 3} acSysPOEActionRes OBJECT-TYPE SYNTAX INTEGER { succeeded(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Power Over Ethenet (PoE) Mangement Field for ACTIONS RESULT. Internal parameter. AC INI-Param: POETable_ActionRes" ::= {acSysPOEEntry 4} acSysPOEPortEnable OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter is used for Power Over Ethenet (PoE) - enable/diasble port PoE. Access: Offline. AC INI-Param: POETable_PortEnable" ::= {acSysPOEEntry 5} acSysPOEPortPower OBJECT-TYPE SYNTAX Unsigned32 (4000..30000) MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter is used for Power Over Ethenet (PoE) - Port Power[mW]. Access: Offline. AC INI-Param: POETable_PortPower" ::= {acSysPOEEntry 6} acSysPOEPortATEnable OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter is used to show if working in mode IEEE 802.3AF (0) or IEEE 802.3AT (1). Access: Offline. AC INI-Param: POETable_PortATEnable" ::= {acSysPOEEntry 7} acSysNetworkSettings OBJECT IDENTIFIER ::= {acSysNetworkConfig 13} acSysNetworkSettingsDisableICMPRedirects OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Disable ICMP Redirect messages. When set to 0 ICMP Redirect messages are not ignored. Access: Instant. AC INI-Param: DisableICMPRedirects" ::= {acSysNetworkSettings 1} acSysSTUN OBJECT IDENTIFIER ::= {acSysNATTraversal 21} acSysSTUNEnable OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is used to enable the STUN module, used for NAT traversal of UDP packets. Access: Offline. AC INI-Param: ENABLESTUN" ::= {acSysSTUN 1} acSysSTUNPrimaryServerIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the primary STUN Server IP address. Range = Legal IP address. Access: Offline. AC INI-Param: STUNSERVERPRIMARYIP" ::= {acSysSTUN 2} acSysSTUNSecondaryServerIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the secondary STUN server IP address. Range = Legal IP address. Access: Offline. AC INI-Param: STUNSERVERSECONDARYIP" ::= {acSysSTUN 3} acSysSTUNBindingLifeTime OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is used to define the NAT binding lifetime, in seconds. STUN refreshes the binding information after this time expires. Range = 0 - 2592000. Access: Offline. AC INI-Param: NATBINDINGDEFAULTTIMEOUT" ::= {acSysSTUN 4} acSysMiscConfig OBJECT IDENTIFIER ::= {acSystemConfiguration 4} acSysDiagnostics OBJECT IDENTIFIER ::= {acSysMiscConfig 1} acSysDiagnosticsEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0) , builtInTest(1) , builtInTestwithPartialFlash(2) , builtInTestWithSDRAM(3) , builtInTestOnUtopiaVxb(4) , internalUse(99) } MAX-ACCESS read-write STATUS current DESCRIPTION "Checks the correct functionality of the different hardware components on the board. On completion of the check, the board sends an EV_END_BIT value, which contains information on the test results of each hardware component. 0 = No diagnostics (default) 1 = Perform diagnostics (full test of DSPs, PCM, Switch, LAN, PHY and Flash) 2 = Perform diagnostics (full test of DSPs, PCM, Switch, LAN, PHY, but partial, test of Flash, a quicker mode). Access: Offline. AC INI-Param: ENABLEDIAGNOSTICS" ::= {acSysDiagnostics 1} acSysDiagnosticsEnablePerformanceThresholdAlarms OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter enables sending SNMP traps and Syslog messages when performance of the device is degraded (according to the configured thresholds). Access: Instant. AC INI-Param: PM_EnableThresholdAlarms" ::= {acSysDiagnostics 2} acSysDiagnosticsListOfActivitiesToLog OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines what activities are to be reported by the device in the form of a log message. Parameter format is x,y,z-... where x,y,z are activity codes to be reported by the device. Supported activity codes: PVC - Parameter Value Changes. AFL - Auxiliary Files Loading. DR - Device Reset. FB - Flash Burning. SWU - SoftWareUpdate. ARD - Access to Restricted Domains. NAA - Non Authorized Access. SPC - Sensitive Parameters Changes. Access: Online. AC INI-Param: ActivityListToLog" ::= {acSysDiagnostics 3} acSysGenericINI OBJECT IDENTIFIER ::= {acSysMiscConfig 2} acSysGenericINILine OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..512)) MAX-ACCESS read-write STATUS current DESCRIPTION "Flexible INI file line. to enter more than one line, use '$@$' between lines. Access: Offline. AC INI-Param: N/A" ::= {acSysGenericINI 1} acSysGenericINISecureStartup OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables or disables secure startup mode. In this mode, downloading of the INI file is restricted to a URL provided in prior configuration (see parameter IniFileURL) or via DHCP. Access: Offline. AC INI-Param: EnableSecureStartup" ::= {acSysGenericINI 2} acSysGenericCli OBJECT IDENTIFIER ::= {acSysMiscConfig 3} acSysGenericCliCommand OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..512)) MAX-ACCESS read-write STATUS current DESCRIPTION "send CLI command. Access: Instant. AC INI-Param: N/A" ::= {acSysGenericCli 1} acSysGenericCliCommandResponse OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..512)) MAX-ACCESS read-only STATUS current DESCRIPTION "get CLI command response. AC INI-Param: N/A" ::= {acSysGenericCli 2} acSysLicenseKey OBJECT IDENTIFIER ::= {acSystemConfiguration 5} acSysLicenseKeyString OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..256)) MAX-ACCESS read-write STATUS current DESCRIPTION "Coded Key specific for board and required features. Access: Offline. AC INI-Param: N/A" ::= {acSysLicenseKey 1} acSysLicenseKeyActiveList OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..484)) MAX-ACCESS read-only STATUS current DESCRIPTION "List of all avtivated features. AC INI-Param: N/A" ::= {acSysLicenseKey 2} acSysFile OBJECT IDENTIFIER ::= {acSystemConfiguration 6} acSysFileCpt OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..47)) MAX-ACCESS read-only STATUS current DESCRIPTION "Defines Call Progress Tone filenames (downloaded by TFTP). AC INI-Param: CALLPROGRESSTONESFILENAME" ::= {acSysFile 1} acSysFileVp OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..47)) MAX-ACCESS read-only STATUS current DESCRIPTION "Defines the name (and path) of the file containing the Voice Prompts. Range = String of ASCII characters. AC INI-Param: VOICEPROMPTSFILENAME" ::= {acSysFile 2} acSysFilePrerecordedTones OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..47)) MAX-ACCESS read-only STATUS current DESCRIPTION "Defines the name (and path) of the file containing the Prerecorded Tones. Range = String of ASCII characters. AC INI-Param: PrerecordedTonesFileName" ::= {acSysFile 3} acSysFileXml OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..47)) MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter is used to indicate the name of the file containing the XML file. AC INI-Param: XMLFileName" ::= {acSysFile 4} acSysFileExternalCoder OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..47)) MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter defines the name of an external coders table. In this table, the user can decide which coders will be used in the system. The original file is a text file, and it is converted by DCONVERT to a bynary file. AC INI-Param: CODERTBLFILENAME" ::= {acSysFile 5} acSysFileUserInfo OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..47)) MAX-ACCESS read-only STATUS current DESCRIPTION "The file name to be loaded. AC INI-Param: N/A" ::= {acSysFile 6} acSysFileDialPlanFileName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..47)) MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter is used to indicate the name of the file containing the Dial Plan. AC INI-Param: gDialPlanFileName" ::= {acSysFile 7} acSysFileTLSPkeyFileName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..47)) MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter defines the name of a private key file (internal). Set to blank to regenerate the key and certificate. AC INI-Param: HTTPSPkeyFileName" ::= {acSysFile 8} acSysFileTLSCertFileName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..47)) MAX-ACCESS read-only STATUS current DESCRIPTION "Defines the name of the HTTPS server certificate file to be downloaded via TFTP. The file must be in base64-encoded PEM format. Range = String[47]. AC INI-Param: HTTPSCertFileName" ::= {acSysFile 9} acSysFileTLSRootFileName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..47)) MAX-ACCESS read-only STATUS current DESCRIPTION "Defines the name of the HTTPS trusted root certificate file to be downloaded via TFTP. The file must be in base64-encoded PEM format. Range = String[47]. AC INI-Param: HTTPSRootFileName" ::= {acSysFile 10} acSysFileFirstVideoFontFileName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..47)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the name of the first file containing the Video Font file index. AC INI-Param: VideoFontFIleName" ::= {acSysFile 11} acSysFileSecondVideoFontFileName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..47)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the name of the second file containing the Video Font file index. AC INI-Param: VideoFontFIleName" ::= {acSysFile 12} acSysFileThirdVideoFontFileName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..47)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the name of the first file containing the Video Font file index. AC INI-Param: VideoFontFIleName" ::= {acSysFile 13} acSysFileV5PortConfFileName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..47)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the name and location of the V5 Port Configuration file. AC INI-Param: V5PortConfigurationFileName" ::= {acSysFile 14} acSysFileAmdSensitivityFileName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..47)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the AMD Sensitivity auxiliary file. AC INI-Param: AmdSensitivityFileName" ::= {acSysFile 15} acSysSecurity OBJECT IDENTIFIER ::= {acSystemConfiguration 7} acSysSecurityTLSVersion OBJECT-TYPE SYNTAX INTEGER { sSL-2-3-and-TLS-1(0) , tLS-1-only(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the supported versions of SSL/TLS. When set to 0, SSL/TLS handshakes always start with SSL 2.0 and switch to TLS 1.0 if both peers support it. When set to 1, TLS 1.0 is the only version supported clients attempting to contact the device using SSL 2.0 will be rejected. Possible values: 0 = SSL 2.0, SSL 3.0, and TLS 1.0 are supported (default) 1 = TLS 1.0 will always be used. Access: Online. AC INI-Param: TLSVersion" ::= {acSysSecurity 1} acSysSecurityOcspEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0) , enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables or disables certificate checking via OCSP. Access: Instant. AC INI-Param: OcspEnable" ::= {acSysSecurity 2} acSysSecurityOcspServerIPType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the OCSP server's IP address Type. 0 - unknown 1 - IPv4 2 - IPv6. Access: Instant. AC INI-Param: N/A" ::= {acSysSecurity 3} acSysSecurityOcspServerIP OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the OCSP server's IP address. Range = Legal IP address. Access: Instant. AC INI-Param: OcspServerIP" ::= {acSysSecurity 4} acSysSecurityOcspServerPort OBJECT-TYPE SYNTAX Unsigned32 (1..32767) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the OCSP server's TCP port number. Range = 1 to 32767. Access: Instant. AC INI-Param: OcspServerPort" ::= {acSysSecurity 5} acSysSecurityOcspDefaultResponse OBJECT-TYPE SYNTAX INTEGER { rejectPeerCertificate(0) , allowPeerCertificate(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines default OCSP behavior when the server cannot be contacted. 0 = reject peer certificate. 1 = allow peer certificate. . Access: Instant. AC INI-Param: OcspDefaultResponse" ::= {acSysSecurity 6} acSysSecurityTLSFIPS140Mode OBJECT-TYPE SYNTAX INTEGER { disabled(0) , enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines whether to enable the FIPS140 mode for TLS. Access: Offline. AC INI-Param: TLS_Fips140_Mode" ::= {acSysSecurity 7} acSysSecurityGenCsrSubjectName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..600)) MAX-ACCESS read-write STATUS current DESCRIPTION "generate CSR Subject Name. Access: Instant. AC INI-Param: N/A" ::= {acSysSecurity 8} acSysSecuritySelfSignedCertificateSubjectName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION " Access: Instant. AC INI-Param: N/A" ::= {acSysSecurity 9} acSysSecurityOcspSecondaryServerIPType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the OCSP secondary server's IP address Type. 0 - unknown 1 - IPv4 2 - IPv6. Access: Instant. AC INI-Param: N/A" ::= {acSysSecurity 10} acSysSecurityOcspSecondaryServerIP OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter defines the OCSP secondary server IP address. Range = Legal IP address. Access: Instant. AC INI-Param: OcspSecondaryServerIP" ::= {acSysSecurity 11} acSysSecurityHTTPSRequireClientCertificate OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Requires client certificates for HTTPS connection. The client certificate must be preloaded on the gateway, and its matching private key must be installed on the managing computer. Time and date must be correctly set on the gateway, for the client certificate to be verified. Access: Online. AC INI-Param: HTTPSRequireClientCertificate" ::= {acSysSecurity 12} acSysSecurityAUPDVerifyCertificates OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter configures the AutoUpdate facility to verify server certificates when using HTTPS. Access: Online. AC INI-Param: AUPDVerifyCertificates" ::= {acSysSecurity 13} acSysSecurityRequireStrictCertification OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Verify the certification strictly - for SSL. Access: Online. AC INI-Param: RequireStrictCert" ::= {acSysSecurity 14} acSysSecurityTLSExpiryCheckStart OBJECT-TYPE SYNTAX Unsigned32 (0..3650) MAX-ACCESS read-write STATUS current DESCRIPTION "The system will report when the TLS server certificate is about to expire within this number of days. Access: Instant. AC INI-Param: TLSExpiryCheckStart" ::= {acSysSecurity 15} acSysSecurityTLSExpiryCheckPeriod OBJECT-TYPE SYNTAX Unsigned32 (1..3650) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines how often the system will check for TLS server certificate expiry (in days). Access: Instant. AC INI-Param: TLSExpiryCheckPeriod" ::= {acSysSecurity 16} acSysIKE OBJECT IDENTIFIER ::= {acSysSecurity 21} -- **************************************** -- acSysIKEPolicy table declaration -- **************************************** acSysIKEPolicyTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysIKEPolicyEntry MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "" ::= {acSysIKE 1} -- **************************************** -- acSysIKEPolicy table entry -- **************************************** acSysIKEPolicyEntry OBJECT-TYPE SYNTAX AcSysIKEPolicyEntry MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "" INDEX {acSysIKEPolicyIndex} ::= {acSysIKEPolicyTable 1} -- **************************************** -- acSysIKEPolicy TABLE -- **************************************** AcSysIKEPolicyEntry ::= SEQUENCE { acSysIKEPolicyIndex Unsigned32, acSysIKEPolicyRowStatus RowStatus, acSysIKEPolicyAction INTEGER, acSysIKEPolicyActionRes INTEGER, acSysIKEPolicyShardKey SnmpAdminString, acSysIKEPolicyLifeInSeconds Unsigned32, acSysIKEPolicyLifeInKB Unsigned32, acSysIKEPolicyProposal0Encryption INTEGER, acSysIKEPolicyProposal1Encryption INTEGER, acSysIKEPolicyProposal2Encryption INTEGER, acSysIKEPolicyProposal3Encryption INTEGER, acSysIKEPolicyProposal0Authentication INTEGER, acSysIKEPolicyProposal1Authentication INTEGER, acSysIKEPolicyProposal2Authentication INTEGER, acSysIKEPolicyProposal3Authentication INTEGER, acSysIKEPolicyProposal0DHGroup INTEGER, acSysIKEPolicyProposal1DHGroup INTEGER, acSysIKEPolicyProposal2DHGroup INTEGER, acSysIKEPolicyProposal3DHGroup INTEGER, acSysIKEPolicyAuthenticationMethod INTEGER } acSysIKEPolicyIndex OBJECT-TYPE SYNTAX Unsigned32 (0..19) MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "This parameter is used for the Internet Key Encryption (IKE) Index Field for line. Internal parameter. AC INI-Param: IKE_DB_INDEX" ::= {acSysIKEPolicyEntry 1} acSysIKEPolicyRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS obsolete DESCRIPTION "This parameter is used for the Internet Key Encryption (IKE) ROWSTATUS Field for line. Internal parameter. AC INI-Param: IKE_DB_ROWSTATUS" ::= {acSysIKEPolicyEntry 2} acSysIKEPolicyAction OBJECT-TYPE SYNTAX INTEGER { none(0) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "This parameter is used for the Internet Key Encryption (IKE) Mangement Field for ACTIONS. Internal parameter. AC INI-Param: IKE_DB_ACTION" ::= {acSysIKEPolicyEntry 3} acSysIKEPolicyActionRes OBJECT-TYPE SYNTAX INTEGER { succeeded(0) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "This parameter is used for the Internet Key Encryption (IKE) Mangement Field for ACTIONS RESULT. Internal parameter. AC INI-Param: IKE_DB_ACTION_RESULT" ::= {acSysIKEPolicyEntry 4} acSysIKEPolicyShardKey OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..80)) MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IKE Policy - Shared Key. Access: Instant. AC INI-Param: IKEPOLICYSHAREDKEY" ::= {acSysIKEPolicyEntry 5} acSysIKEPolicyLifeInSeconds OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IKE Policy - IKE SA LifeTime in seconds. Access: Instant. AC INI-Param: IKEPOLICYLIFEINSEC" ::= {acSysIKEPolicyEntry 6} acSysIKEPolicyLifeInKB OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IKE Policy - IKE SA LifeTime in KB. Access: Instant. AC INI-Param: IKEPOLICYLIFEINKB" ::= {acSysIKEPolicyEntry 7} acSysIKEPolicyProposal0Encryption OBJECT-TYPE SYNTAX INTEGER { dES-CBC(1) , triple-DES-CBC(2) , aES(3) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IKE Policy - Proposal 0 encryption type. Access: Instant. AC INI-Param: IKEPOLICYPROPOSALENCRYPTION_0" ::= {acSysIKEPolicyEntry 8} acSysIKEPolicyProposal1Encryption OBJECT-TYPE SYNTAX INTEGER { dES-CBC(1) , triple-DES-CBC(2) , aES(3) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IKE Policy - Proposal 1 encryption type. Access: Instant. AC INI-Param: IKEPOLICYPROPOSALENCRYPTION_1" ::= {acSysIKEPolicyEntry 9} acSysIKEPolicyProposal2Encryption OBJECT-TYPE SYNTAX INTEGER { dES-CBC(1) , triple-DES-CBC(2) , aES(3) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IKE Policy - Proposal 2 encryption type. Access: Instant. AC INI-Param: IKEPOLICYPROPOSALENCRYPTION_2" ::= {acSysIKEPolicyEntry 10} acSysIKEPolicyProposal3Encryption OBJECT-TYPE SYNTAX INTEGER { dES-CBC(1) , triple-DES-CBC(2) , aES(3) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IKE Policy - Proposal 3 encryption type. Access: Instant. AC INI-Param: IKEPOLICYPROPOSALENCRYPTION_3" ::= {acSysIKEPolicyEntry 11} acSysIKEPolicyProposal0Authentication OBJECT-TYPE SYNTAX INTEGER { hMAC-SHA-1-96(2) , hMAC-MD5-96(4) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IKE Policy - Proposal 0 authentication type. Access: Instant. AC INI-Param: IKEPOLICYPROPOSALAUTHENTICATION_0" ::= {acSysIKEPolicyEntry 12} acSysIKEPolicyProposal1Authentication OBJECT-TYPE SYNTAX INTEGER { hMAC-SHA-1-96(2) , hMAC-MD5-96(4) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IKE Policy - Proposal 1 authentication type. Access: Instant. AC INI-Param: IKEPOLICYPROPOSALAUTHENTICATION_1" ::= {acSysIKEPolicyEntry 13} acSysIKEPolicyProposal2Authentication OBJECT-TYPE SYNTAX INTEGER { hMAC-SHA-1-96(2) , hMAC-MD5-96(4) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IKE Policy - Proposal 2 authentication type. Access: Instant. AC INI-Param: IKEPOLICYPROPOSALAUTHENTICATION_2" ::= {acSysIKEPolicyEntry 14} acSysIKEPolicyProposal3Authentication OBJECT-TYPE SYNTAX INTEGER { hMAC-SHA-1-96(2) , hMAC-MD5-96(4) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IKE Policy - Proposal 3 authentication type. Access: Instant. AC INI-Param: IKEPOLICYPROPOSALAUTHENTICATION_3" ::= {acSysIKEPolicyEntry 15} acSysIKEPolicyProposal0DHGroup OBJECT-TYPE SYNTAX INTEGER { dH-786-BIT(0) , dH-1024-BIT(1) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IKE Policy - Proposal 0 Diffie Hellman Group. Access: Instant. AC INI-Param: IKEPOLICYPROPOSALDHGROUP_0" ::= {acSysIKEPolicyEntry 16} acSysIKEPolicyProposal1DHGroup OBJECT-TYPE SYNTAX INTEGER { dH-786-BIT(0) , dH-1024-BIT(1) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IKE Policy - Proposal 1 Diffie Hellman Group. Access: Instant. AC INI-Param: IKEPOLICYPROPOSALDHGROUP_1" ::= {acSysIKEPolicyEntry 17} acSysIKEPolicyProposal2DHGroup OBJECT-TYPE SYNTAX INTEGER { dH-786-BIT(0) , dH-1024-BIT(1) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IKE Policy - Proposal 2 Diffie Hellman Group. Access: Instant. AC INI-Param: IKEPOLICYPROPOSALDHGROUP_2" ::= {acSysIKEPolicyEntry 18} acSysIKEPolicyProposal3DHGroup OBJECT-TYPE SYNTAX INTEGER { dH-786-BIT(0) , dH-1024-BIT(1) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IKE Policy - Proposal 3 Diffie Hellman Group. Access: Instant. AC INI-Param: IKEPOLICYPROPOSALDHGROUP_3" ::= {acSysIKEPolicyEntry 19} acSysIKEPolicyAuthenticationMethod OBJECT-TYPE SYNTAX INTEGER { presharedKey(0) , rsaSignature(1) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "This parameter is used for Internet Key Encryption (IKE) Policy - IKE Authentication Method (Preshared key/ RSA). Access: Offline. AC INI-Param: IKEPOLICYAUTHENTICATIONMETHOD" ::= {acSysIKEPolicyEntry 20} acSysIPSec OBJECT IDENTIFIER ::= {acSysSecurity 22} acSysIPSecEnable OBJECT-TYPE SYNTAX INTEGER { no(0) , yes(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "IPsec Enable flag. Access: Offline. AC INI-Param: ENABLEIPSEC" ::= {acSysIPSec 1} acSysIPSecDpdMode OBJECT-TYPE SYNTAX INTEGER { disabled(0) , periodic(1) , ondemand(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "IPsec Dead Peer Detection (RFC 3706) - Mode of Operation. One of the following values: '0' - Disabled (Default) '1' - Periodic '2' - On demand. Access: Instant. AC INI-Param: IPSECDPDMODE" ::= {acSysIPSec 2} acSysIPSecIKECertificateExtValidate OBJECT-TYPE SYNTAX INTEGER { disabled(0) , enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables or disables certificate extension checking for IKE. Access: Instant. AC INI-Param: IKEcertificateExtValidate" ::= {acSysIPSec 3} -- **************************************** -- acSysIPSecSPD table declaration -- **************************************** acSysIPSecSPDTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysIPSecSPDEntry MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "" ::= {acSysIPSec 21} -- **************************************** -- acSysIPSecSPD table entry -- **************************************** acSysIPSecSPDEntry OBJECT-TYPE SYNTAX AcSysIPSecSPDEntry MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "" INDEX {acSysIPSecSPDIndex} ::= {acSysIPSecSPDTable 1} -- **************************************** -- acSysIPSecSPD TABLE -- **************************************** AcSysIPSecSPDEntry ::= SEQUENCE { acSysIPSecSPDIndex Unsigned32, acSysIPSecSPDRowStatus RowStatus, acSysIPSecSPDAction INTEGER, acSysIPSecSPDActionRes INTEGER, acSysIPSecSPDPolicyRemoteIPAddr SnmpAdminString, acSysIPSecSPDPolicySrcPort Unsigned32, acSysIPSecSPDPolicyDestPort Unsigned32, acSysIPSecSPDPolicyProtocol Unsigned32, acSysIPSecSPDKeyExchangeMethodIndex Unsigned32, acSysIPSecSPDLifeInSeconds Unsigned32, acSysIPSecSPDLifeInKB Unsigned32, acSysIPSecSPDProposal0Encryption INTEGER, acSysIPSecSPDProposal1Encryption INTEGER, acSysIPSecSPDProposal2Encryption INTEGER, acSysIPSecSPDProposal3Encryption INTEGER, acSysIPSecSPDProposal0Authentication INTEGER, acSysIPSecSPDProposal1Authentication INTEGER, acSysIPSecSPDProposal2Authentication INTEGER, acSysIPSecSPDProposal3Authentication INTEGER, acSysIPSecSPDPolicyLocalIPAddrType INTEGER, acSysIPSecSPDMode INTEGER, acSysIPSecSPDPolicyRemoteTunnelIPAddress IpAddress, acSysIPSecSPDPolicyLocalTunnelIPAddress IpAddress, acSysIPSecSPDPolicyRemoteTunnelSubnetMask IpAddress } acSysIPSecSPDIndex OBJECT-TYPE SYNTAX Unsigned32 (0..19) MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "Security Policy Database (SPD) Index Field for line. Internal parameter. AC INI-Param: SPD_INDEX" ::= {acSysIPSecSPDEntry 1} acSysIPSecSPDRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS obsolete DESCRIPTION "Security Policy Database (SPD) ROWSTATUS field for line. Internal parameter. AC INI-Param: SPD_ROWSTATUS" ::= {acSysIPSecSPDEntry 2} acSysIPSecSPDAction OBJECT-TYPE SYNTAX INTEGER { none(0) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "Security Policy Database (SPD) Mangement Field for ACTIONS. Internal parameter. AC INI-Param: SPD_ACTION" ::= {acSysIPSecSPDEntry 3} acSysIPSecSPDActionRes OBJECT-TYPE SYNTAX INTEGER { succeeded(0) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Security Policy Database (SPD) Mangement Field for ACTIONS RESULT. Internal parameter. AC INI-Param: SPD_ACTION_RESULT" ::= {acSysIPSecSPDEntry 4} acSysIPSecSPDPolicyRemoteIPAddr OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..99)) MAX-ACCESS read-create STATUS obsolete DESCRIPTION "This parameter is used for Secure Internet Protocol (IPsec) Policy Policy - Remote IP address as IP or Host Name. Access: Instant. AC INI-Param: IPSECPOLICYREMOTEIPADDRESS" ::= {acSysIPSecSPDEntry 5} acSysIPSecSPDPolicySrcPort OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-create STATUS obsolete DESCRIPTION "This parameter is used for Secure Internet Protocol (IPsec) Policy Policy - Source Port. Access: Instant. AC INI-Param: IPSECPOLICYSRCPORT" ::= {acSysIPSecSPDEntry 6} acSysIPSecSPDPolicyDestPort OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-create STATUS obsolete DESCRIPTION "This parameter is used for Secure Internet Protocol (IPsec) Policy Policy - Destination Port. Access: Instant. AC INI-Param: IPSECPOLICYDSTPORT" ::= {acSysIPSecSPDEntry 7} acSysIPSecSPDPolicyProtocol OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-create STATUS obsolete DESCRIPTION "This parameter is used for Secure Internet Protocol (IPsec) Policy Policy - Protocol. Access: Instant. AC INI-Param: IPSECPOLICYPROTOCOL" ::= {acSysIPSecSPDEntry 8} acSysIPSecSPDKeyExchangeMethodIndex OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-create STATUS obsolete DESCRIPTION "This parameter is used for the Secure Internet Protocol (IPsec) Policy - Index into the Key Exchange Method Table (IKE Table). Access: Offline. AC INI-Param: IPSECPOLICYKEYEXCHANGEMETHODINDEX" ::= {acSysIPSecSPDEntry 9} acSysIPSecSPDLifeInSeconds OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IPsec Policy - IPSec SA LifeTime in seconds. Access: Instant. AC INI-Param: IPSECPOLICYLIFEINSEC" ::= {acSysIPSecSPDEntry 10} acSysIPSecSPDLifeInKB OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IPsec Policy - IPSec SA LifeTime in KB. Access: Instant. AC INI-Param: IPSECPOLICYLIFEINKB" ::= {acSysIPSecSPDEntry 11} acSysIPSecSPDProposal0Encryption OBJECT-TYPE SYNTAX INTEGER { none(0) , dES-CBC(1) , triple-DES-CBC(2) , aES(3) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IPsec Policy - Proposal 0 encryption type. Access: Instant. AC INI-Param: IPSECPOLICYPROPOSALENCRYPTION_0" ::= {acSysIPSecSPDEntry 12} acSysIPSecSPDProposal1Encryption OBJECT-TYPE SYNTAX INTEGER { none(0) , dES-CBC(1) , triple-DES-CBC(2) , aES(3) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IPsec Policy - Proposal 1 encryption type. Access: Instant. AC INI-Param: IPSECPOLICYPROPOSALENCRYPTION_1" ::= {acSysIPSecSPDEntry 13} acSysIPSecSPDProposal2Encryption OBJECT-TYPE SYNTAX INTEGER { none(0) , dES-CBC(1) , triple-DES-CBC(2) , aES(3) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IPsec Policy - Proposal 2 encryption type. Access: Instant. AC INI-Param: IPSECPOLICYPROPOSALENCRYPTION_2" ::= {acSysIPSecSPDEntry 14} acSysIPSecSPDProposal3Encryption OBJECT-TYPE SYNTAX INTEGER { none(0) , dES-CBC(1) , triple-DES-CBC(2) , aES(3) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IPsec Policy - Proposal 3 encryption type. Access: Instant. AC INI-Param: IPSECPOLICYPROPOSALENCRYPTION_3" ::= {acSysIPSecSPDEntry 15} acSysIPSecSPDProposal0Authentication OBJECT-TYPE SYNTAX INTEGER { hMAC-SHA-1-96(2) , hMAC-MD5-96(4) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IPsec Policy - Proposal 0 authentication type. Access: Instant. AC INI-Param: IPSECPOLICYPROPOSALAUTHENTICATION_0" ::= {acSysIPSecSPDEntry 16} acSysIPSecSPDProposal1Authentication OBJECT-TYPE SYNTAX INTEGER { hMAC-SHA-1-96(2) , hMAC-MD5-96(4) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IPsec Policy - Proposal 0 authentication type. Access: Instant. AC INI-Param: IPSECPOLICYPROPOSALAUTHENTICATION_1" ::= {acSysIPSecSPDEntry 17} acSysIPSecSPDProposal2Authentication OBJECT-TYPE SYNTAX INTEGER { hMAC-SHA-1-96(2) , hMAC-MD5-96(4) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IPsec Policy - Proposal 0 authentication type. Access: Instant. AC INI-Param: IPSECPOLICYPROPOSALAUTHENTICATION_2" ::= {acSysIPSecSPDEntry 18} acSysIPSecSPDProposal3Authentication OBJECT-TYPE SYNTAX INTEGER { hMAC-SHA-1-96(2) , hMAC-MD5-96(4) , not-set(10) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "IPsec Policy - Proposal 0 authentication type. Access: Instant. AC INI-Param: IPSECPOLICYPROPOSALAUTHENTICATION_3" ::= {acSysIPSecSPDEntry 19} acSysIPSecSPDPolicyLocalIPAddrType OBJECT-TYPE SYNTAX INTEGER { oam(0) , control(2) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "This parameter is used for Secure Internet Protocol (IPsec) Policy - Local IP address type (OAM/Control). Access: Offline. AC INI-Param: IPSECPOLICYLOCALIPADDRESSTYPE" ::= {acSysIPSecSPDEntry 20} acSysIPSecSPDMode OBJECT-TYPE SYNTAX INTEGER { transport(0) , tunneling(1) } MAX-ACCESS read-create STATUS obsolete DESCRIPTION "This parameter is used for Secure Internet Protocol (IPsec) Policy - Mode of Operation (Transport/Tunneling). '0' - Transport '1' - Tunneling. Access: Instant. AC INI-Param: IPSECMODE" ::= {acSysIPSecSPDEntry 21} acSysIPSecSPDPolicyRemoteTunnelIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS obsolete DESCRIPTION "This parameter is used for Secure Internet Protocol (IPsec) Policy - IP Address of the Remote IPSec Tunnel Endpoint. Access: Instant. AC INI-Param: IPSECPOLICYREMOTETUNNELIPADDRESS" ::= {acSysIPSecSPDEntry 22} acSysIPSecSPDPolicyLocalTunnelIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS obsolete DESCRIPTION "This parameter is used for Secure Internet Protocol (IPsec) Policy - IP Address of the Remote IPSec Tunnel Endpoint. Access: Instant. AC INI-Param: IPSECPOLICYLOCALTUNNELIPADDRESS" ::= {acSysIPSecSPDEntry 23} acSysIPSecSPDPolicyRemoteTunnelSubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS obsolete DESCRIPTION "This parameter is used for Secure Internet Protocol (IPsec) Policy - Subnet Mask of the Remote IPSec Address. Access: Instant. AC INI-Param: IPSECPOLICYREMOTESUBNETMASK" ::= {acSysIPSecSPDEntry 24} -- **************************************** -- acSysIPsecProposal table declaration -- **************************************** acSysIPsecProposalTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysIPsecProposalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IPsec Proposal table" ::= {acSysIPSec 22} -- **************************************** -- acSysIPsecProposal table entry -- **************************************** acSysIPsecProposalEntry OBJECT-TYPE SYNTAX AcSysIPsecProposalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysIPsecProposalIndex} ::= {acSysIPsecProposalTable 1} -- **************************************** -- acSysIPsecProposal TABLE -- **************************************** AcSysIPsecProposalEntry ::= SEQUENCE { acSysIPsecProposalIndex Unsigned32, acSysIPsecProposalRowStatus RowStatus, acSysIPsecProposalAction INTEGER, acSysIPsecProposalActionRes INTEGER, acSysIPsecProposalEncryptionAlgorithm INTEGER, acSysIPsecProposalAuthenticationAlgorithm INTEGER, acSysIPsecProposalDiffieHellmanGroup INTEGER } acSysIPsecProposalIndex OBJECT-TYPE SYNTAX Unsigned32 (0..4) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index Field for line. AC INI-Param: IPsecProposalTable_Index" ::= {acSysIPsecProposalEntry 1} acSysIPsecProposalRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "ROWSTATUS Field for line. AC INI-Param: IPsecProposalTable_RowStatus" ::= {acSysIPsecProposalEntry 2} acSysIPsecProposalAction OBJECT-TYPE SYNTAX INTEGER { none(0) } MAX-ACCESS read-create STATUS current DESCRIPTION "Mangement Field for ACTIONS. AC INI-Param: IPsecProposalTable_Action" ::= {acSysIPsecProposalEntry 3} acSysIPsecProposalActionRes OBJECT-TYPE SYNTAX INTEGER { succeeded(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Mangement Field for ACTIONS RESULT. AC INI-Param: IPsecProposalTable_ActionRes" ::= {acSysIPsecProposalEntry 4} acSysIPsecProposalEncryptionAlgorithm OBJECT-TYPE SYNTAX INTEGER { none(0) , desCbc(1) , tripleDesCbc(2) , aes(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Selects the encryption (privacy) algorithm to use. Access: Online. AC INI-Param: IPsecProposalTable_EncryptionAlgorithm" ::= {acSysIPsecProposalEntry 5} acSysIPsecProposalAuthenticationAlgorithm OBJECT-TYPE SYNTAX INTEGER { none(0) , hmacSha1-96(2) , hmacMd5-96(4) } MAX-ACCESS read-create STATUS current DESCRIPTION "Selects the message authentication (integrity) algorithm to use. Access: Online. AC INI-Param: IPsecProposalTable_AuthenticationAlgorithm" ::= {acSysIPsecProposalEntry 6} acSysIPsecProposalDiffieHellmanGroup OBJECT-TYPE SYNTAX INTEGER { group1-768Bits(0) , group2-1024Bits(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "Selects the Diffie-Hellman group to use. Access: Online. AC INI-Param: IPsecProposalTable_DHGroup" ::= {acSysIPsecProposalEntry 7} -- **************************************** -- acSysIPsecSA table declaration -- **************************************** acSysIPsecSATable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysIPsecSAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IPsec SA table" ::= {acSysIPSec 23} -- **************************************** -- acSysIPsecSA table entry -- **************************************** acSysIPsecSAEntry OBJECT-TYPE SYNTAX AcSysIPsecSAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysIPsecSAIndex} ::= {acSysIPsecSATable 1} -- **************************************** -- acSysIPsecSA TABLE -- **************************************** AcSysIPsecSAEntry ::= SEQUENCE { acSysIPsecSAIndex Unsigned32, acSysIPsecSARowStatus RowStatus, acSysIPsecSAAction Unsigned32, acSysIPsecSAActionRes Unsigned32, acSysIPsecSARemoteEndpointAddress SnmpAdminString, acSysIPsecSAAuthenticationMethod INTEGER, acSysIPsecSASharedKey SnmpAdminString, acSysIPsecSASourcePort Unsigned32, acSysIPsecSADestPort Unsigned32, acSysIPsecSAProtocol Unsigned32, acSysIPsecSAPhase1SaLifetimeInSec Unsigned32, acSysIPsecSAPhase2SaLifetimeInSec Unsigned32, acSysIPsecSAPhase2SaLifetimeInKB Unsigned32, acSysIPsecSADPDmode INTEGER, acSysIPsecSAIPsecMode INTEGER, acSysIPsecSARemoteTunnelAddress SnmpAdminString, acSysIPsecSARemoteSubnetIPAddress SnmpAdminString, acSysIPsecSARemoteSubnetPrefixLength Unsigned32, acSysIPsecSAInterfaceName RowPointer } acSysIPsecSAIndex OBJECT-TYPE SYNTAX Unsigned32 (0..20) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index Field for line. AC INI-Param: IPsecSATable_Index" ::= {acSysIPsecSAEntry 1} acSysIPsecSARowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "ROWSTATUS Field for line. AC INI-Param: IPsecSATable_RowStatus" ::= {acSysIPsecSAEntry 2} acSysIPsecSAAction OBJECT-TYPE SYNTAX Unsigned32 (0..0) MAX-ACCESS read-create STATUS current DESCRIPTION "Mangement Field for ACTIONS. AC INI-Param: IPsecSATable_Action" ::= {acSysIPsecSAEntry 3} acSysIPsecSAActionRes OBJECT-TYPE SYNTAX Unsigned32 (0..0) MAX-ACCESS read-only STATUS current DESCRIPTION "Mangement Field for ACTIONS RESULT. AC INI-Param: IPsecSATable_ActionRes" ::= {acSysIPsecSAEntry 4} acSysIPsecSARemoteEndpointAddress OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..98)) MAX-ACCESS read-create STATUS current DESCRIPTION "IP address or DNS host name of the peer. Access: Online. AC INI-Param: IPsecSATable_RemoteEndpointAddressOrName" ::= {acSysIPsecSAEntry 5} acSysIPsecSAAuthenticationMethod OBJECT-TYPE SYNTAX INTEGER { presharedKey(0) , rSASignature(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "Selects the method used for peer authentication during IKE main mode. Access: Online. AC INI-Param: IPsecSATable_AuthenticationMethod" ::= {acSysIPsecSAEntry 6} acSysIPsecSASharedKey OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..79)) MAX-ACCESS read-create STATUS current DESCRIPTION "Defines the pre-shared key (in textual format). Access: Online. AC INI-Param: IPsecSATable_SharedKey" ::= {acSysIPsecSAEntry 7} acSysIPsecSASourcePort OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "Defines the source port to which this configuration applies. Access: Online. AC INI-Param: IPsecSATable_SourcePort" ::= {acSysIPsecSAEntry 8} acSysIPsecSADestPort OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "Defines the destination port to which this configuration applies. Access: Online. AC INI-Param: IPsecSATable_DestPort" ::= {acSysIPsecSAEntry 9} acSysIPsecSAProtocol OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "Defines the protocol type to which this configuration applies. Standard IP protocol numbers should be used, e.g.: 0 = Any protocol (default) 17 = UDP 6 = TCP . Access: Online. AC INI-Param: IPsecSATable_Protocol" ::= {acSysIPsecSAEntry 10} acSysIPsecSAPhase1SaLifetimeInSec OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-create STATUS current DESCRIPTION "Determines the duration (in seconds) for which the negotiated IKE SA (main mode) is valid. After the time expires, the SA is re-negotiated. Access: Online. AC INI-Param: IPsecSATable_Phase1SaLifetimeInSec" ::= {acSysIPsecSAEntry 11} acSysIPsecSAPhase2SaLifetimeInSec OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-create STATUS current DESCRIPTION "Determines the duration (in seconds) for which the negotiated IPSec SA (quick mode) is valid. After the time expires, the SA is re-negotiated. Access: Online. AC INI-Param: IPsecSATable_Phase2SaLifetimeInSec" ::= {acSysIPsecSAEntry 12} acSysIPsecSAPhase2SaLifetimeInKB OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-create STATUS current DESCRIPTION "Determines the maximum volume of traffic (in kilobytes) for which the negotiated IPSec SA (quick mode) is valid. Access: Online. AC INI-Param: IPsecSATable_Phase2SaLifetimeInKB" ::= {acSysIPsecSAEntry 13} acSysIPsecSADPDmode OBJECT-TYPE SYNTAX INTEGER { dPDDisabled(0) , dPDPeriodic(1) , dPDOnDemand(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Controls dead peer detection (DPD) as per RFC 3706. Access: Online. AC INI-Param: IPsecSATable_DPDmode" ::= {acSysIPsecSAEntry 14} acSysIPsecSAIPsecMode OBJECT-TYPE SYNTAX INTEGER { transport(0) , tunnel(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "Selects the IPSec mode of operation. 0 = Transport mode (default) 1 = Tunnel mode . Access: Online. AC INI-Param: IPsecSATable_IPsecMode" ::= {acSysIPsecSAEntry 15} acSysIPsecSARemoteTunnelAddress OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..45)) MAX-ACCESS read-create STATUS current DESCRIPTION "IP address of the peer router. Access: Online. AC INI-Param: IPsecSATable_RemoteTunnelAddress" ::= {acSysIPsecSAEntry 16} acSysIPsecSARemoteSubnetIPAddress OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..45)) MAX-ACCESS read-create STATUS current DESCRIPTION "IP address of the remote subnetwork. Access: Online. AC INI-Param: IPsecSATable_RemoteSubnetIPAddress" ::= {acSysIPsecSAEntry 17} acSysIPsecSARemoteSubnetPrefixLength OBJECT-TYPE SYNTAX Unsigned32 (0..128) MAX-ACCESS read-create STATUS current DESCRIPTION "Prefix length of the Remote Subnet IP Address parameter (in bits). Access: Online. AC INI-Param: IPsecSATable_RemoteSubnetPrefixLength" ::= {acSysIPsecSAEntry 18} acSysIPsecSAInterfaceName OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-create STATUS current DESCRIPTION "Select the OID of the interface name corresponding to the one appearing in the interface table. The OID should be 1.3.6.1.4.1.5003.9.10.10.1.3.1.30.22.1.11. acSysInterfaceIndex Note: when ignore a default value will be SET: 0.0. Access: Online. AC INI-Param: IPsecSATable_InterfaceName" ::= {acSysIPsecSAEntry 19} acFirewall OBJECT IDENTIFIER ::= {acSysSecurity 23} -- **************************************** -- acSysAccessList table declaration -- **************************************** acSysAccessListTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysAccessListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acFirewall 1} -- **************************************** -- acSysAccessList table entry -- **************************************** acSysAccessListEntry OBJECT-TYPE SYNTAX AcSysAccessListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysAccessListIndex} ::= {acSysAccessListTable 1} -- **************************************** -- acSysAccessList TABLE -- **************************************** AcSysAccessListEntry ::= SEQUENCE { acSysAccessListIndex Unsigned32, acSysAccessListRowStatus RowStatus, acSysAccessListAction INTEGER, acSysAccessListActionRes INTEGER, acSysAccessListSourceIP SnmpAdminString, acSysAccessListNetMask IpAddress, acSysAccessListStartPort Unsigned32, acSysAccessListEndPort Unsigned32, acSysAccessListProtocol SnmpAdminString, acSysAccessListPacketSize Unsigned32, acSysAccessListByteRate Unsigned32, acSysAccessListByteBurst Unsigned32, acSysAccessListAllowType INTEGER, acSysAccessListMatchCount Unsigned32, acSysAccessListInterfaceName SnmpAdminString, acSysAccessListUseSpecificInterface INTEGER, acSysAccessListSourcePort Unsigned32, acSysAccessListPrefixLength Unsigned32 } acSysAccessListIndex OBJECT-TYPE SYNTAX Unsigned32 (0..49) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index Field for line. Internal parameter. AC INI-Param: ACCESSLIST_Index" ::= {acSysAccessListEntry 1} acSysAccessListRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "ROWSTATUS field for line. Internal parameter. AC INI-Param: N/A" ::= {acSysAccessListEntry 2} acSysAccessListAction OBJECT-TYPE SYNTAX INTEGER { none(0) } MAX-ACCESS read-create STATUS current DESCRIPTION "Mangement Field for ACTIONS. Internal parameter. AC INI-Param: N/A" ::= {acSysAccessListEntry 3} acSysAccessListActionRes OBJECT-TYPE SYNTAX INTEGER { succeeded(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Mangement Field for ACTIONS RESULT. Internal parameter. AC INI-Param: N/A" ::= {acSysAccessListEntry 4} acSysAccessListSourceIP OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..60)) MAX-ACCESS read-create STATUS current DESCRIPTION "Source IP for access rule. Access: Online. AC INI-Param: ACCESSLIST_Source_IP" ::= {acSysAccessListEntry 5} acSysAccessListNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Mask for this access rule (bitwise ANDed with the source IP of the packet). Access: Online. AC INI-Param: ACCESSLIST_Net_Mask" ::= {acSysAccessListEntry 6} acSysAccessListStartPort OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "Port range - start. Access: Online. AC INI-Param: ACCESSLIST_Start_Port" ::= {acSysAccessListEntry 7} acSysAccessListEndPort OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "Port range - end. Access: Online. AC INI-Param: ACCESSLIST_End_Port" ::= {acSysAccessListEntry 8} acSysAccessListProtocol OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..10)) MAX-ACCESS read-create STATUS current DESCRIPTION "IP user-level protocol (TCP, UDP, ICMP, ESP, SIP, MGCP, TPNCP, ANY or numeric value). Access: Online. AC INI-Param: ACCESSLIST_Protocol" ::= {acSysAccessListEntry 9} acSysAccessListPacketSize OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "Maximum packet size (0 = unused). Access: Online. AC INI-Param: ACCESSLIST_Packet_Size" ::= {acSysAccessListEntry 10} acSysAccessListByteRate OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-create STATUS current DESCRIPTION "Allowed traffic in bytes per second (0 = unused). Access: Online. AC INI-Param: ACCESSLIST_Byte_Rate" ::= {acSysAccessListEntry 11} acSysAccessListByteBurst OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-create STATUS current DESCRIPTION "Allowed traffic burst in bytes (0 = unused). Access: Online. AC INI-Param: ACCESSLIST_Byte_Burst" ::= {acSysAccessListEntry 12} acSysAccessListAllowType OBJECT-TYPE SYNTAX INTEGER { notSet(0) , allow(1) , block(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Allow or block traffic matching this rule. Access: Online. AC INI-Param: ACCESSLIST_Allow_Type" ::= {acSysAccessListEntry 13} acSysAccessListMatchCount OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Statistics: number of matched packets. AC INI-Param: ACCESSLIST_MatchCount" ::= {acSysAccessListEntry 14} acSysAccessListInterfaceName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..15)) MAX-ACCESS read-create STATUS current DESCRIPTION "Name of the specific interface the rule applies to. None - default value when no interface was chosen. Access: Online. AC INI-Param: ACCESSLIST_Interface_ID" ::= {acSysAccessListEntry 15} acSysAccessListUseSpecificInterface OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "Rule for specific interface or for the entire interfaces. Access: Online. AC INI-Param: ACCESSLIST_Use_Specific_Interface" ::= {acSysAccessListEntry 16} acSysAccessListSourcePort OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "Source Port. Access: Online. AC INI-Param: ACCESSLIST_Source_Port" ::= {acSysAccessListEntry 17} acSysAccessListPrefixLength OBJECT-TYPE SYNTAX Unsigned32 (0..128) MAX-ACCESS read-create STATUS current DESCRIPTION "Prefix length of source IP address (defining a subnet). Access: Online. AC INI-Param: ACCESSLIST_PrefixLen" ::= {acSysAccessListEntry 18} acSysMediaEncription OBJECT IDENTIFIER ::= {acSysSecurity 24} acSysMediaEncriptionRTPAuthenticationDisableTx OBJECT-TYPE SYNTAX INTEGER { inactive(0) , active(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "On a secured RTP session, determines whether to enable Authentication on transmitted RTP packets. One of the following values: 0 = Enable 1 = Disable. Access: Online. AC INI-Param: RTPAuthenticationDisableTx" ::= {acSysMediaEncription 1} acSysMediaEncriptionRTPAuthenticationDisableRx OBJECT-TYPE SYNTAX INTEGER { inactive(0) , active(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "On a secured RTP session, determines whether to enable Authentication on received RTP packets 0 = Enable 1 = Disable. Access: Online. AC INI-Param: RTPAuthenticationDisableRx" ::= {acSysMediaEncription 2} acSysMediaEncriptionRTPEncryptionDisableTx OBJECT-TYPE SYNTAX INTEGER { inactive(0) , active(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "On a secured RTP session, determines whether to enable Encryption on transmitted RTP packets. One of the following values: 0 = Enable 1 = Disable. Access: Online. AC INI-Param: RTPEncryptionDisableTx" ::= {acSysMediaEncription 3} acSysMediaEncriptionRTPEncryptionDisableRx OBJECT-TYPE SYNTAX INTEGER { inactive(0) , active(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "On a secured RTP session, determines whether to enable Encryption on transmitted RTP packets. One of the following values: 0 = Enable 1 = Disable. Access: Online. AC INI-Param: RTPEncryptionDisableRx" ::= {acSysMediaEncription 4} acSysMediaEncriptionRTCPEncryptionDisableTx OBJECT-TYPE SYNTAX INTEGER { inactive(0) , active(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "On a secured RTP session, determines whether to enable Encryption on transmitted RTCP packets. One of the following values: 0 = Enable 1 = Disable. Access: Online. AC INI-Param: RTCPEncryptionDisableTx" ::= {acSysMediaEncription 5} acSysMediaEncriptionRTCPEncryptionDisableRx OBJECT-TYPE SYNTAX INTEGER { inactive(0) , active(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "On a secured RTP session, determines whether to enable Encryption on received RTCP packets. One of the following values: 0 = Enable 1 = Disable. Access: Online. AC INI-Param: RTCPEncryptionDisableRx" ::= {acSysMediaEncription 6} acSys802dot1x OBJECT IDENTIFIER ::= {acSysSecurity 25} acSys802dot1xMode OBJECT-TYPE SYNTAX INTEGER { disabled(0) , eapMd5(1) , protectedEap(2) , eapTls(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables support for IEEE 802.1x physical port security. 0 = Disabled 1 = EAP-MD5 2 = Protected EAP (PEAP) 3 = EAP-TLS . Access: Instant. AC INI-Param: 802.1xMode" ::= {acSys802dot1x 1} acSys802dot1xUsername OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..31)) MAX-ACCESS read-write STATUS current DESCRIPTION "Username for IEEE 802.1x support. Access: Instant. AC INI-Param: 802.1xUsername" ::= {acSys802dot1x 2} acSys802dot1xPassword OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..31)) MAX-ACCESS read-write STATUS current DESCRIPTION "Password for IEEE 802.1x support. Access: Instant. AC INI-Param: 802.1xPassword" ::= {acSys802dot1x 3} acSys802dot1xVerifyPeerCertificate OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Verify Peer Certificate for IEEE 802.1x support. Access: Instant. AC INI-Param: 802.1xVerifyPeerCertificate" ::= {acSys802dot1x 4} acSysSRTP OBJECT IDENTIFIER ::= {acSysMediaEncription 21} acSysSRTPPacketMKISize OBJECT-TYPE SYNTAX Unsigned32 (0..4) MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the size of the parameter Master Key Identifier (MKI) in SRTP Tx packets. One of the following values: 0 = MKI Disabled 1 - 4 = size (bytes of MKI). Access: Online. AC INI-Param: SRTPTxPacketMKISize" ::= {acSysSRTP 1} acSysSerialIF OBJECT IDENTIFIER ::= {acSystemConfiguration 8} acSysSerialIFBaudRate OBJECT-TYPE SYNTAX INTEGER { r1200(1200) , r2400(2400) , r4800(4800) , r9600(9600) , r14400(14400) , r19200(19200) , r38400(38400) , r57600(57600) , r115200(115200) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables changes to the Serial Baud Rate for Simplified Message Desk Interface (SMDI). Standard values: 1200, 2400, 9600, 14400, 19200, 38400, 57600, 115200. Access: Offline. AC INI-Param: SerialBaudRate" ::= {acSysSerialIF 1} acSysSerialIFData OBJECT-TYPE SYNTAX Unsigned32 (7..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Changes the serial data bit for the Simplified Message Desk Interface (SMDI). 7 = 7 Bit 8 = 8 Bit. Access: Offline. AC INI-Param: SerialData" ::= {acSysSerialIF 2} acSysSerialIFParity OBJECT-TYPE SYNTAX INTEGER { none(0) , odd(1) , even(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Changes the serial parity for the Simplified Message Desk Interface (SMDI). 0 = None 1 = Odd 2 = Even. Access: Offline. AC INI-Param: SerialParity" ::= {acSysSerialIF 3} acSysSerialIFStop OBJECT-TYPE SYNTAX Unsigned32 (1..2) MAX-ACCESS read-write STATUS current DESCRIPTION "Changes the serial stop for the Simplified Message Desk Interface (SMDI). 1 = 1 Bit 2 = 2 Bit. Access: Offline. AC INI-Param: SerialStop" ::= {acSysSerialIF 4} acSysSerialIFFlowControl OBJECT-TYPE SYNTAX INTEGER { none(0) , hardware(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Changes the serial flow control for the Simplified Message Desk Interface (SMDI). 0 = None 1 = Hardware. Access: Offline. AC INI-Param: SerialFlowControl" ::= {acSysSerialIF 5} acVoiceStream OBJECT IDENTIFIER ::= {acSystemConfiguration 9} acVoiceStreamStatus OBJECT-TYPE SYNTAX INTEGER { disabled(0) , enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/disables the voice streaming for all voice source types (HTTP, NFS, Local Storage). When enabled, the module requires some system resources, such as tasks and memory allocation. 0 = Disable 1 = Enable. Access: Offline. AC INI-Param: N/A" ::= {acVoiceStream 1} acVoiceStreamUploadMethod OBJECT-TYPE SYNTAX INTEGER { httpPostMethod(0) , httpPutMethod(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the HTTP request type for uploading the voice stream to the file server. 0 = POST 1 = PUT. Access: Offline. AC INI-Param: N/A" ::= {acVoiceStream 2} acVoiceStreamUploadPostUri OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..59)) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the URI used on the POST request, to upload voice data from the media server to a web server. This parameter is used only when using the HTTP POST for recording and the command is not issued by the Lib (tpncp protocol). The path needs to be set to the upload script on the web server. . Access: Offline. AC INI-Param: N/A" ::= {acVoiceStream 3} acSysAMS OBJECT IDENTIFIER ::= {acSystemConfiguration 10} acSysAMSProfile OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable AMS Advanced IVR play functionality. 0 = Disable 1 = Enable. Access: Offline. AC INI-Param: AMSProfile" ::= {acSysAMS 1} acSysAMSApsIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the destination UDP port to which the Heartbeat Packets are sent. Range = IP address in dotted notation xxx.xxx.xxx.xxx Default = 0.0.0.0. Access: Offline. AC INI-Param: HeartbeatDestIP" ::= {acSysAMS 2} acSysAMSApsPort OBJECT-TYPE SYNTAX Unsigned32 (0..64000) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the destination UDP port to which the heartbeat packets are sent. Access: Offline. AC INI-Param: HeartbeatDestPort" ::= {acSysAMS 3} acSysAMSPrimaryLanguage OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..3)) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the Primary Language for the AMS. Range = String[3] - language ISO string. Access: Instant. AC INI-Param: AMSPrimaryLanguage" ::= {acSysAMS 4} acSysAMSSecondaryLanguage OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..3)) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the Secondary Language for the AMS. Range = String[3] - language ISO string. Access: Instant. AC INI-Param: AMSSecondaryLanguage" ::= {acSysAMS 5} acSysAMSAPSProfile OBJECT-TYPE SYNTAX INTEGER { vpDatProvidedAudio(0) , apsProvidedAudio(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if the system should expect to use APS bundle (vp.dat and segments.xml files), or if the system should expect the vp.dat file only. A 1 means that an APS bundle should be used. A 0 means that the system should use vp.dat only. The default setting is 1, meaning expect APS bundle. Access: Offline. AC INI-Param: APSEnabled" ::= {acSysAMS 6} acSysAMSForceRepositoryEnable OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates that a new audio repository (consisting of VP and XML files) should always be uploaded to the board regardless of whether signals are still being played on the old repository. Access: Instant. AC INI-Param: AMSForceRepositoryUpdateEnabled" ::= {acSysAMS 7} acSysNetworkFileSystem OBJECT IDENTIFIER ::= {acSystemConfiguration 11} -- **************************************** -- acSysNFS table declaration -- **************************************** acSysNFSTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysNFSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acSysNetworkFileSystem 21} -- **************************************** -- acSysNFS table entry -- **************************************** acSysNFSEntry OBJECT-TYPE SYNTAX AcSysNFSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysNFSIndex} ::= {acSysNFSTable 1} -- **************************************** -- acSysNFS TABLE -- **************************************** AcSysNFSEntry ::= SEQUENCE { acSysNFSIndex Unsigned32, acSysNFSRowStatus RowStatus, acSysNFSAction INTEGER, acSysNFSActionRes INTEGER, acSysNFSHostOrIP SnmpAdminString, acSysNFSRootPath SnmpAdminString, acSysNFSNfsVersion INTEGER, acSysNFSAuthType INTEGER, acSysNFSUID Unsigned32, acSysNFSGID Unsigned32, acSysNFSVlanType INTEGER } acSysNFSIndex OBJECT-TYPE SYNTAX Unsigned32 (0..15) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index Field for line. Internal parameter. Index can be up to 15 in dependency of board type. AC INI-Param: NFSServers_Index" ::= {acSysNFSEntry 1} acSysNFSRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "ROWSTATUS field for line. Internal parameter. AC INI-Param: N/A" ::= {acSysNFSEntry 2} acSysNFSAction OBJECT-TYPE SYNTAX INTEGER { none(0) } MAX-ACCESS read-create STATUS current DESCRIPTION "Mangement Field for ACTIONS. Internal parameter. AC INI-Param: N/A" ::= {acSysNFSEntry 3} acSysNFSActionRes OBJECT-TYPE SYNTAX INTEGER { succeeded(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Mangement Field for ACTIONS RESULT. Internal parameter. AC INI-Param: N/A" ::= {acSysNFSEntry 4} acSysNFSHostOrIP OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..39)) MAX-ACCESS read-create STATUS current DESCRIPTION "The domain name or IP address of the NFS server. If a domain name is provided, then a DNS server must be configured. Access: Online. AC INI-Param: NFSServers_HostOrIP" ::= {acSysNFSEntry 5} acSysNFSRootPath OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..99)) MAX-ACCESS read-create STATUS current DESCRIPTION "Path to the root of the exported file system. Access: Online. AC INI-Param: NFSServers_RootPath" ::= {acSysNFSEntry 6} acSysNFSNfsVersion OBJECT-TYPE SYNTAX INTEGER { v2(2) , v3(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "NFS version to use with this remote file system, 2 or 3 (default). Access: Online. AC INI-Param: NFSServers_NfsVersion" ::= {acSysNFSEntry 7} acSysNFSAuthType OBJECT-TYPE SYNTAX INTEGER { null(0) , unix(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "Identifies the authentication method used with this remote file system, 0 for AUTH_NULL, 1 for AUTH_UNIX (default). Access: Online. AC INI-Param: NFSServers_AuthType" ::= {acSysNFSEntry 8} acSysNFSUID OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-create STATUS current DESCRIPTION "User ID used in authentication if using AUTH_UNIX. The default is 0. Access: Online. AC INI-Param: NFSServers_UID" ::= {acSysNFSEntry 9} acSysNFSGID OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-create STATUS current DESCRIPTION "Group ID used in authentication if using AUTH_UNIX. The default is 1. Access: Online. AC INI-Param: NFSServers_GID" ::= {acSysNFSEntry 10} acSysNFSVlanType OBJECT-TYPE SYNTAX INTEGER { oam(0) , media(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "The VLAN, OAM(0) or Media(1), to use when accessing this remote file system. The default is to use the media VLAN. This parameters applies only if multiple IP addresses are configured on this board. Access: Online. AC INI-Param: NFSServers_VlanType" ::= {acSysNFSEntry 11} acSysHA OBJECT IDENTIFIER ::= {acSystemConfiguration 12} acSysHAGlobalIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Defines the M3K global IP address to be used by the active module in HA system. (Dotted format notation. e.g., 192.10.1.255). Range = Legal IP address. Access: Offline. AC INI-Param: M3KGlobalIpAddr" ::= {acSysHA 1} acSysHARemoteAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the Maintenance IF IP address of the remote HA unit. Relevant to M4K and SW-SBC. Access: Offline. AC INI-Param: HARemoteAddress" ::= {acSysHA 2} acSysHARevertive OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "When enabled, unit with higher HA priority will take the active state in HA system. Relevant to M4K and SW-SBC. Access: Offline. AC INI-Param: HARevertiveEnabled" ::= {acSysHA 3} acSysHAPriority OBJECT-TYPE SYNTAX Unsigned32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Enables the user to define the HA priority to decide if unit should be in Active or Redundant state (Valid only when acSysHARevertive is set) Relevant to M4K and SW-SBC. Access: Offline. AC INI-Param: HAPriority" ::= {acSysHA 4} acSysHARedundantPriority OBJECT-TYPE SYNTAX Unsigned32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Enables the user to define the Redundant HA priority to decide if unit should be in Active or Redundant state. Valid range is 1-10. Relevant to M4K and SW-SBC. Access: Offline. AC INI-Param: N/A" ::= {acSysHA 5} acSysHAPingEnabled OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enabling network monitor using ping to test reachability from defined source interface, a drop in reachability will trigger switch over to redundant unit. Access: Online. AC INI-Param: HAPingEnabled" ::= {acSysHA 6} acSysHAPingDestination OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the ping destination IP address of HA network monitor reachability module. Access: Online. AC INI-Param: HAPingDestination" ::= {acSysHA 7} acSysHAPingSourceIfName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the ping source inteface to test for HA network monitor reachability module. Access: Online. AC INI-Param: HAPingSourceIfName" ::= {acSysHA 8} acSysHAPingTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..60) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the ping time out value in seconds for HA network monitor reachability module. Access: Online. AC INI-Param: HAPingTimeout" ::= {acSysHA 9} acSysHAPingRetries OBJECT-TYPE SYNTAX Unsigned32 (0..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the ping retries value for HA network monitor reachability module. Access: Online. AC INI-Param: HAPingRetries" ::= {acSysHA 10} acSysTransmission OBJECT IDENTIFIER ::= {acSystemConfiguration 13} acSysTransmissionType OBJECT-TYPE SYNTAX INTEGER { none(0) , opticalSonetSdh(1) , copperDs3(2) , copperE1Ds1(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the PSTN Transmission type for the board: optical SONET / SDH or copper DS3. Access: Offline. AC INI-Param: PSTNTransmissionType" ::= {acSysTransmission 1} acSysTiming OBJECT IDENTIFIER ::= {acSystemConfiguration 14} acSysTimingMode OBJECT-TYPE SYNTAX INTEGER { standAlone(0) , external(1) , lineSync(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the PSTN Timing synchonization mode of the Gateway. One of the following values: TM_External_MODE(1) -External Timing mode - use the SAT trunks Centralized Line Timing to synchronize the Gateway with one of the PSTN interfaces. TM_LineSync_MODE(2) -Distributed Line Timing mode (for the 1610 boards)- without using the SAT timing module. TM_Standalone_MODE(0) -Non-synchronized mode - each board or TPM is synchronized internally from one of the PSTN interfaces without using the SAT timing module. Access: Online. AC INI-Param: TMMode" ::= {acSysTiming 1} acSysTimingValidationTime OBJECT-TYPE SYNTAX Unsigned32 (0..15) MAX-ACCESS read-write STATUS current DESCRIPTION "Reference validation time. Applicable for External timing and Line timing timing references. Range: 0 - 15 minutes. Resolution: 1 minute. Access: Online. AC INI-Param: TMReferenceValidationTime" ::= {acSysTiming 2} acSysTimingClockToDeriveA OBJECT-TYPE SYNTAX INTEGER { deriveREFFromLineClock1(0) , deriveInternalClock(4) , clockFromReceiveSide(7) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Which Clock to use in sync mode. Access: Online. AC INI-Param: TMClockToDerive_A" ::= {acSysTiming 3} acSysTimingClockToDeriveB OBJECT-TYPE SYNTAX INTEGER { deriveREFFromLineClock1(0) , deriveInternalClock(4) , clockFromReceiveSide(7) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Which Clock to use in sync mode. Access: Online. AC INI-Param: TMClockToDerive_B" ::= {acSysTiming 4} acSysTimingExternalIFType OBJECT-TYPE SYNTAX INTEGER { e1CRC4(0) , e1CAS(1) , e1FAS(2) , t1D4(3) , t1ESF(4) , t12(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the external line reference (BITS) transmission format. Access: Online. AC INI-Param: TMExternalIFType" ::= {acSysTiming 5} acSysTimingLoopBackRef1 OBJECT-TYPE SYNTAX INTEGER { loopDisable(0) , loopEnable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables loopback state, by connecting Rx path towards Tx path. Access: Online. AC INI-Param: TMLoopBackExternalRef1" ::= {acSysTiming 6} acSysTimingLoopBackRef2 OBJECT-TYPE SYNTAX INTEGER { loopDisable(0) , loopEnable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables loopback state, by connecting Rx path towards Tx path. Access: Online. AC INI-Param: TMLoopBackExternalRef2" ::= {acSysTiming 7} acSysTimingTransmitControl OBJECT-TYPE SYNTAX INTEGER { systemClock(0) , aIS(1) , disableTransmit(2) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Enables loopback state, by connecting Rx path towards Tx path. Access: Online. AC INI-Param: TMTransmitControl" ::= {acSysTiming 8} acSysTimingE1LineBuildOut OBJECT-TYPE SYNTAX INTEGER { tm75OhmNormal(0) , tm120OhmNormal(1) , tm75OhmHighReturnLoss(4) , tm120OhmHighReturnLoss(5) , tm75OhmNormalGappedClock(6) , tm120OhmNormalGappedClock(7) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Sets the transmission power between the timing module on the SAT and the E1 external reference clock (ohms). This parameter is only relevant for the Mediant 3000.This parameter is enabled when bspTimingModuleCfgTimingMode is set to TM_External_MODE(1). One of the following values: E_75_OHM_with_high_return_loss(4),E_120_OHM_with_high_return_loss(5),E_75_OHM_normal_PLUS_enable_transmit_and_receive_gapped_clock(6),E_120_OHM_normal_PLUS_enable_transmit_and_receive_gapped_clock(7),E_75_OHM_normal(0),E_120_OHM_normal(1). Access: Online. AC INI-Param: TME1LineBuildOut " ::= {acSysTiming 9} acSysTimingT1LineBuildOut OBJECT-TYPE SYNTAX INTEGER { dSX10to133feet0dBCSU(0) , dSX1133to266feet(1) , dSX1266to399feet(2) , dSX1399to533feet(3) , dSX1533to655feet(4) , dSX10to133ft0dBgappedclock(7) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "External Reference Transmit Line Build Out. Access: Online. AC INI-Param: TMT1LineBuildOut" ::= {acSysTiming 10} acSysLDAP OBJECT IDENTIFIER ::= {acSystemConfiguration 15} acSysLDAPServerIp OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This parameter defines the IP address in dotted format notation. e.g., 192.10.1.255 Range = Legal IP address. Access: Online. AC INI-Param: LDAPSERVERIP" ::= {acSysLDAP 1} acSysLDAPServerPort OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Defines the port number for the LDAP server. Range = Valid port number. Access: Online. AC INI-Param: LDAPSERVERPORT" ::= {acSysLDAP 2} acSysLDAPServerMaxRespondTime OBJECT-TYPE SYNTAX Unsigned32 (0..86400) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Defines the period of time the module will wait for LDAP server response (seconds). Access: Instant. AC INI-Param: LDAPSERVERMAXRESPONDTIME" ::= {acSysLDAP 3} acSysLDAPServerDomainName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..255)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This parameter is used to indicate the name of LDAP server. Access: Online. AC INI-Param: LDAPSERVERDOMAINNAME" ::= {acSysLDAP 4} acSysLDAPSearchDN OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..255)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This parameter is used to indicate the search DN for LDAP search request. Access: Online. AC INI-Param: LDAPSEARCHDN" ::= {acSysLDAP 5} acSysLDAPPassword OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..255)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This parameter is used to indicate the user password of LDAP server. Access: Online. AC INI-Param: LDAPPASSWORD" ::= {acSysLDAP 6} acSysLDAPBindDN OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..255)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This parameter is used to indicate the of LDAP server bind DN. Access: Online. AC INI-Param: LDAPBINDDN" ::= {acSysLDAP 7} acSysLDAPServiceEnable OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to either enable or disable LDAP service. 0- disable (default) 1 - enable. Access: Offline. AC INI-Param: LDAPSERVICEENABLE" ::= {acSysLDAP 8} acSysLDAPCacheEnable OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disable using the cashe in LDAP. 0- disable (default) 1 - enable. Access: Offline. AC INI-Param: LDAPCACHEENABLE" ::= {acSysLDAP 9} acSysLDAPCacheEntryTimeout OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The time (in seconds) that an entry in the LDAP cache is valid. Access: Online. AC INI-Param: LDAPCACHEENTRYTIMEOUT" ::= {acSysLDAP 10} acSysLDAPCacheEntryRemovalTimeout OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The time (in seconds) that an entry in the LDAP cache is removed from cache. Access: Online. AC INI-Param: LDAPCACHEENTRYREMOVALTIMEOUT" ::= {acSysLDAP 11} asSysNqm OBJECT IDENTIFIER ::= {acSystemConfiguration 16} -- **************************************** -- acSysNqmSender table declaration -- **************************************** acSysNqmSenderTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysNqmSenderEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {asSysNqm 21} -- **************************************** -- acSysNqmSender table entry -- **************************************** acSysNqmSenderEntry OBJECT-TYPE SYNTAX AcSysNqmSenderEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysNqmSenderIndex} ::= {acSysNqmSenderTable 1} -- **************************************** -- acSysNqmSender TABLE -- **************************************** AcSysNqmSenderEntry ::= SEQUENCE { acSysNqmSenderIndex Unsigned32, acSysNqmSenderRowStatus RowStatus, acSysNqmSenderAction INTEGER, acSysNqmSenderActionRes INTEGER, acSysNqmSenderSenderName SnmpAdminString, acSysNqmSenderActive INTEGER, acSysNqmSenderTargetIpAddress SnmpAdminString, acSysNqmSenderTargetPort Unsigned32, acSysNqmSenderPacketInterval Unsigned32, acSysNqmSenderPayloadSize Unsigned32, acSysNqmSenderIpTos Unsigned32, acSysNqmSenderTimeout Unsigned32, acSysNqmSenderRttThreshold Unsigned32, acSysNqmSenderJitterThreshold Unsigned32, acSysNqmSenderPacketLossThershold Unsigned32, acSysNqmSenderProbingConfigName RowPointer, acSysNqmSenderSourceInterfaceName RowPointer } acSysNqmSenderIndex OBJECT-TYPE SYNTAX Unsigned32 (0..9) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index Field for line. Internal parameter. AC INI-Param: NqmSenderTable_Index" ::= {acSysNqmSenderEntry 1} acSysNqmSenderRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "ROWSTATUS field for line. Internal parameter. AC INI-Param: NqmSenderTable_RowStatus" ::= {acSysNqmSenderEntry 2} acSysNqmSenderAction OBJECT-TYPE SYNTAX INTEGER { none(0) } MAX-ACCESS read-create STATUS current DESCRIPTION "Mangement Field for ACTIONS. Internal parameter. AC INI-Param: NqmSenderTable_Action" ::= {acSysNqmSenderEntry 3} acSysNqmSenderActionRes OBJECT-TYPE SYNTAX INTEGER { succeeded(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Mangement Field for ACTIONS RESULT. Internal parameter. AC INI-Param: NqmSenderTable_ActionRes" ::= {acSysNqmSenderEntry 4} acSysNqmSenderSenderName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..64)) MAX-ACCESS read-create STATUS current DESCRIPTION "Sender descriptive name. Access: Online. AC INI-Param: NqmSenderTable_SenderName" ::= {acSysNqmSenderEntry 5} acSysNqmSenderActive OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "Sender enable. Access: Online. AC INI-Param: NqmSenderTable_Active" ::= {acSysNqmSenderEntry 6} acSysNqmSenderTargetIpAddress OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..45)) MAX-ACCESS read-create STATUS current DESCRIPTION "Target IP address. Access: Online. AC INI-Param: NqmSenderTable_TargetIpAddress" ::= {acSysNqmSenderEntry 7} acSysNqmSenderTargetPort OBJECT-TYPE SYNTAX Unsigned32 (3900..3990) MAX-ACCESS read-create STATUS current DESCRIPTION "Target transport layer port number. Ports are: 3900, 3910, 3920, 3930, 3940, 3950, 3960, 3970, 3980, 3990. Access: Online. AC INI-Param: NqmSenderTable_TargetPort" ::= {acSysNqmSenderEntry 8} acSysNqmSenderPacketInterval OBJECT-TYPE SYNTAX Unsigned32 (5..1000) MAX-ACCESS read-create STATUS current DESCRIPTION "Interval between each packet transmitting [msec]. Access: Online. AC INI-Param: NqmSenderTable_PacketInterval" ::= {acSysNqmSenderEntry 9} acSysNqmSenderPayloadSize OBJECT-TYPE SYNTAX Unsigned32 (28..1420) MAX-ACCESS read-create STATUS current DESCRIPTION "Size of IP payload [bytes]. Access: Online. AC INI-Param: NqmSenderTable_PayloadSize" ::= {acSysNqmSenderEntry 10} acSysNqmSenderIpTos OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "TOS value in the IP header. Access: Online. AC INI-Param: NqmSenderTable_IpTos" ::= {acSysNqmSenderEntry 11} acSysNqmSenderTimeout OBJECT-TYPE SYNTAX Unsigned32 (0..32000) MAX-ACCESS read-create STATUS current DESCRIPTION "Receive timeout on expected packet. Access: Online. AC INI-Param: NqmSenderTable_Timeout" ::= {acSysNqmSenderEntry 12} acSysNqmSenderRttThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..32000) MAX-ACCESS read-create STATUS current DESCRIPTION "Maximum allowable Round Trip Time [msec], if exceeded some action is needed. Access: Online. AC INI-Param: NqmSenderTable_RttThreshold" ::= {acSysNqmSenderEntry 13} acSysNqmSenderJitterThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..32000) MAX-ACCESS read-create STATUS current DESCRIPTION "Maximum allowable Jitter [msec], if exceeded some action is needed. Access: Online. AC INI-Param: NqmSenderTable_JitterThreshold" ::= {acSysNqmSenderEntry 14} acSysNqmSenderPacketLossThershold OBJECT-TYPE SYNTAX Unsigned32 (0..32000) MAX-ACCESS read-create STATUS current DESCRIPTION "Maximum allowable Packet Loss, if exceeded some action is needed. Access: Online. AC INI-Param: NqmSenderTable_PacketLossThershold" ::= {acSysNqmSenderEntry 15} acSysNqmSenderProbingConfigName OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-create STATUS current DESCRIPTION "Name of corresponding probe in probing table. Access: Online. AC INI-Param: NqmSenderTable_ProbingConfigName" ::= {acSysNqmSenderEntry 16} acSysNqmSenderSourceInterfaceName OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-create STATUS current DESCRIPTION "Name of source interface. Access: Online. AC INI-Param: NqmSenderTable_SourceInterfaceName" ::= {acSysNqmSenderEntry 17} -- **************************************** -- acSysNqmProbing table declaration -- **************************************** acSysNqmProbingTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysNqmProbingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {asSysNqm 22} -- **************************************** -- acSysNqmProbing table entry -- **************************************** acSysNqmProbingEntry OBJECT-TYPE SYNTAX AcSysNqmProbingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysNqmProbingIndex} ::= {acSysNqmProbingTable 1} -- **************************************** -- acSysNqmProbing TABLE -- **************************************** AcSysNqmProbingEntry ::= SEQUENCE { acSysNqmProbingIndex Unsigned32, acSysNqmProbingRowStatus RowStatus, acSysNqmProbingAction INTEGER, acSysNqmProbingActionRes INTEGER, acSysNqmProbingProbeName SnmpAdminString, acSysNqmProbingDuration Unsigned32, acSysNqmProbingFrequency Unsigned32, acSysNqmProbingLifeSpan Unsigned32, acSysNqmProbingStartTime SnmpAdminString, acSysNqmProbingHistoryEntriesToKeep Unsigned32 } acSysNqmProbingIndex OBJECT-TYPE SYNTAX Unsigned32 (0..9) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index Field for line. Internal parameter. AC INI-Param: NqmProbingTable_Index" ::= {acSysNqmProbingEntry 1} acSysNqmProbingRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "ROWSTATUS field for line. Internal parameter. AC INI-Param: NqmProbingTable_RowStatus" ::= {acSysNqmProbingEntry 2} acSysNqmProbingAction OBJECT-TYPE SYNTAX INTEGER { none(0) } MAX-ACCESS read-create STATUS current DESCRIPTION "Mangement Field for ACTIONS. Internal parameter. AC INI-Param: NqmProbingTable_Action" ::= {acSysNqmProbingEntry 3} acSysNqmProbingActionRes OBJECT-TYPE SYNTAX INTEGER { succeeded(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Mangement Field for ACTIONS RESULT. Internal parameter. AC INI-Param: NqmProbingTable_ActionRes" ::= {acSysNqmProbingEntry 4} acSysNqmProbingProbeName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..64)) MAX-ACCESS read-create STATUS current DESCRIPTION "Probe descriptive name. Access: Online. AC INI-Param: NqmProbingTable_ProbeName" ::= {acSysNqmProbingEntry 5} acSysNqmProbingDuration OBJECT-TYPE SYNTAX Unsigned32 (20..32000) MAX-ACCESS read-create STATUS current DESCRIPTION "Duration of probing session [sec]. Access: Online. AC INI-Param: NqmProbingTable_Duration" ::= {acSysNqmProbingEntry 6} acSysNqmProbingFrequency OBJECT-TYPE SYNTAX Unsigned32 (0..32000) MAX-ACCESS read-create STATUS current DESCRIPTION "Time interval between the start of two consecutive probing sessions [sec]. Access: Online. AC INI-Param: NqmProbingTable_Frequency" ::= {acSysNqmProbingEntry 7} acSysNqmProbingLifeSpan OBJECT-TYPE SYNTAX Unsigned32 (0..2000000000) MAX-ACCESS read-create STATUS current DESCRIPTION "Life span of this probe [sec]. Access: Online. AC INI-Param: NqmProbingTable_LifeSpan" ::= {acSysNqmProbingEntry 8} acSysNqmProbingStartTime OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..64)) MAX-ACCESS read-create STATUS current DESCRIPTION "start time of this probe - now | pending | yyyy:MM:dd:HH:mm:ss. Access: Online. AC INI-Param: NqmProbingTable_StartTime" ::= {acSysNqmProbingEntry 9} acSysNqmProbingHistoryEntriesToKeep OBJECT-TYPE SYNTAX Unsigned32 (1..1000) MAX-ACCESS read-create STATUS current DESCRIPTION "Number of probing result entries to keep in the history file. Access: Online. AC INI-Param: NqmProbingTable_HistoryEntriesToKeep" ::= {acSysNqmProbingEntry 10} -- **************************************** -- acSysNqmResponder table declaration -- **************************************** acSysNqmResponderTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysNqmResponderEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {asSysNqm 23} -- **************************************** -- acSysNqmResponder table entry -- **************************************** acSysNqmResponderEntry OBJECT-TYPE SYNTAX AcSysNqmResponderEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysNqmResponderIndex} ::= {acSysNqmResponderTable 1} -- **************************************** -- acSysNqmResponder TABLE -- **************************************** AcSysNqmResponderEntry ::= SEQUENCE { acSysNqmResponderIndex Unsigned32, acSysNqmResponderRowStatus RowStatus, acSysNqmResponderAction INTEGER, acSysNqmResponderActionRes INTEGER, acSysNqmResponderResponderName SnmpAdminString, acSysNqmResponderActive Unsigned32, acSysNqmResponderLocalPort Unsigned32, acSysNqmResponderSourceInterfaceName RowPointer } acSysNqmResponderIndex OBJECT-TYPE SYNTAX Unsigned32 (0..9) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index Field for line. Internal parameter. AC INI-Param: NqmResponderTable_Index" ::= {acSysNqmResponderEntry 1} acSysNqmResponderRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "ROWSTATUS field for line. Internal parameter. AC INI-Param: NqmResponderTable_RowStatus" ::= {acSysNqmResponderEntry 2} acSysNqmResponderAction OBJECT-TYPE SYNTAX INTEGER { none(0) } MAX-ACCESS read-create STATUS current DESCRIPTION "Mangement Field for ACTIONS. Internal parameter. AC INI-Param: NqmResponderTable_Action" ::= {acSysNqmResponderEntry 3} acSysNqmResponderActionRes OBJECT-TYPE SYNTAX INTEGER { succeeded(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Mangement Field for ACTIONS RESULT. Internal parameter. AC INI-Param: NqmResponderTable_ActionRes" ::= {acSysNqmResponderEntry 4} acSysNqmResponderResponderName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..64)) MAX-ACCESS read-create STATUS current DESCRIPTION "Responder descriptive name. Access: Online. AC INI-Param: NqmResponderTable_ResponderName" ::= {acSysNqmResponderEntry 5} acSysNqmResponderActive OBJECT-TYPE SYNTAX Unsigned32 (0..1) MAX-ACCESS read-create STATUS current DESCRIPTION "Responder Enable. Access: Online. AC INI-Param: NqmResponderTable_Active" ::= {acSysNqmResponderEntry 6} acSysNqmResponderLocalPort OBJECT-TYPE SYNTAX Unsigned32 (3900..3990) MAX-ACCESS read-create STATUS current DESCRIPTION "Local transport layer port number. Ports are: 3900, 3910, 3920, 3930, 3940, 3950, 3960, 3970, 3980, 3990. Access: Online. AC INI-Param: NqmResponderTable_LocalPort" ::= {acSysNqmResponderEntry 7} acSysNqmResponderSourceInterfaceName OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-create STATUS current DESCRIPTION "Name of source interface. Access: Online. AC INI-Param: NqmResponderTable_SourceInterfaceName" ::= {acSysNqmResponderEntry 8} acSystemStatus OBJECT IDENTIFIER ::= {acSystem 2} acSysType OBJECT IDENTIFIER ::= {acSystemStatus 1} acSysTypeProduct OBJECT-TYPE SYNTAX INTEGER { acUnknown(0) , acTrunkPack-08(1) , acMediaPack-108(2) , acMediaPack-124(3) , acTrunkPack-1600(20) , acTPM1100(22) , acTrunkPack-260-IpMedia(23) , acTrunkPack-1610(24) , acMediaPack-104(25) , acMediaPack-102(26) , acTrunkPack-1610-SB(29) , acTrunkPack-1610-IpMedia(30) , acTrunkPack-MEDIANT2000(31) , acTrunkPack-STRETTO2000(32) , acTrunkPack-IPMServer2000(33) , acTrunkPack-2810(34) , acTrunkPack-260-UN-IpMedia (35) , acTrunkPack-260-IpMedia-30Ch(36) , acTrunkPack-260-IpMedia-60Ch(37) , acTrunkPack-260-IpMedia-120Ch(38) , acTrunkPack-260RT-IpMedia-30Ch(39) , acTrunkPack-260RT-IpMedia-60Ch(40) , acTrunkPack-260RT-IpMedia-120Ch(41) , acTrunkPack-260(42) , acTrunkPack-260-UN (43) , acTPM1100-PCM(44) , acTrunkPack-6310(45) , acTPM6300(46) , acMediant1000(47) , acIPMedia3000(48) , acMediant3000(49) , acStretto3000(50) , acTrunkPack-6310-IpMedia(51) , acTrunkPack-6310-SB(52) , acATP-1610(53) , acATP-260(54) , acATP-260-UN(55) , acMediaPack-118(56) , acMediaPack114(57) , acMediaPack112(58) , acTrunkPack-6310-T3(59) , acMediant3000-T3(60) , acIPmedia3000-T3(61) , acTrunkPack-6310-T3-IpMedia(62) , acTrunkPack-8410(63) , acTrunkPack-8410-IpMedia(64) , acMediant-600(65) , acTrunkPack-12610(66) , acMediant1000-MSBG(67) , acMediant-600-MSBG(68) , acMediant800-MSBG(69) , acMediant-4000(70) , acMediant1000-ESBC(71) , acMediant800-ESBC(72) , acHosted(73) , acMediant-850-MSBG(74) , acMediant-850-ESBC(75) , acMediant-500-MSBG(76) , acMediant-500-ESBC(77) , acMediant-2600(78) , acMediant-VE-SBC(79) , acMediant-VE-H-SBC(80) , acMediant-SE-SBC(81) , acMediant-SE-H-SBC(82) , acMediant-6000-SBC(83) , acMediant-500L-MSBG(84) , acMediant-500L-ESBC(85) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the Board. AC INI-Param: N/A" ::= {acSysType 1} acSysTypeDSP OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Dsp Type. AC INI-Param: N/A" ::= {acSysType 2} acSysTypeModule OBJECT-TYPE SYNTAX INTEGER { soloist (0) , second(1) , first(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " AC INI-Param: N/A" ::= {acSysType 3} acSysTypeCPUSpeed OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "CPU Speed. AC INI-Param: N/A" ::= {acSysType 4} acSysVersion OBJECT IDENTIFIER ::= {acSystemStatus 2} acSysVersionSoftware OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "TrunkPack Software Version. AC INI-Param: N/A" ::= {acSysVersion 1} acSysVersionFlash OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Flash [BootLoader] Version. AC INI-Param: N/A" ::= {acSysVersion 2} acSysVersionIniFile OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Ini file version. AC INI-Param: INIFileVersion" ::= {acSysVersion 3} acSysVersionSoftwareDate OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "TrunkPack Software Date. AC INI-Param: N/A" ::= {acSysVersion 4} acSysId OBJECT IDENTIFIER ::= {acSystemStatus 3} acSysIdName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name fo the board. AC INI-Param: N/A" ::= {acSysId 1} acSysIdSerialNumber OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "serial number of board. AC INI-Param: N/A" ::= {acSysId 2} acSysIdSlotNumber OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number. AC INI-Param: N/A" ::= {acSysId 3} acSysIdFirstSerialNumber OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The device's first serial number. When the device is part of a dual module board this is the first module's serial number. When the device is the first module in a dual module or the device is not in a dual module board, the values for asSysIdSerialNumber and acSysIdFirstSerialNumber are the same. AC INI-Param: N/A" ::= {acSysId 4} acSysCount OBJECT IDENTIFIER ::= {acSystemStatus 4} acSysCountDSPs OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "DSP Count. AC INI-Param: N/A" ::= {acSysCount 1} acSysCountChannels OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Channel Count. Analog or Mixed board - the returned value is the number of analog channels. Digital board - the number of digitial channels. AC INI-Param: N/A" ::= {acSysCount 2} acSysCountTrunks OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Trunks Count. AC INI-Param: N/A" ::= {acSysCount 3} acSysState OBJECT IDENTIFIER ::= {acSystemStatus 5} acSysStateTemperature OBJECT-TYPE SYNTAX Unsigned32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of the board in degrees Celsius, should not go higher then 60!. AC INI-Param: N/A" ::= {acSysState 1} acSysStateOperational OBJECT-TYPE SYNTAX INTEGER { disabled(1) , enabled(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operational state of the gateway. AC INI-Param: N/A" ::= {acSysState 2} acSysStateHAupdateInProgress OBJECT-TYPE SYNTAX INTEGER { updateDone(1) , updateInProgress(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates during update process, which done between active and redundant boards. AC INI-Param: N/A" ::= {acSysState 3} acSysStateGWSeverity OBJECT-TYPE SYNTAX INTEGER { noAlarm(0) , indeterminate(1) , warning(2) , minor(3) , major(4) , critical(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The highest alarm severity on the device. AC INI-Param: N/A" ::= {acSysState 4} acSysStateIsPstnManagementEnable OBJECT-TYPE SYNTAX INTEGER { disable(0) , enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Is Pstn Management Enable 0 - Disable 1 - Enable. AC INI-Param: N/A" ::= {acSysState 5} acSysStateErrorMessage OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..512)) MAX-ACCESS read-only STATUS current DESCRIPTION "Error Messages from the board. AC INI-Param: N/A" ::= {acSysState 6} acSysStateErrorID OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Error Message ID. Access: Instant. AC INI-Param: N/A" ::= {acSysState 7} acSysStateDataCpuUtilization OBJECT-TYPE SYNTAX Unsigned32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Data CPU usage in percentage. AC INI-Param: N/A" ::= {acSysState 8} acSysStateDataMemoryUtilization OBJECT-TYPE SYNTAX Unsigned32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Data memory usage in percentage. AC INI-Param: N/A" ::= {acSysState 9} acSysNetwork OBJECT IDENTIFIER ::= {acSystemStatus 6} acSysEthernet OBJECT IDENTIFIER ::= {acSysNetwork 1} acSysEthernetFirstPortDuplexMode OBJECT-TYPE SYNTAX INTEGER { halfDuplex(0) , fullDuplex(1) , forceModeValue(2) , notAvailable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "full-duplex or half-duplex connection. AC INI-Param: N/A" ::= {acSysEthernet 1} acSysEthernetFirstPortSpeed OBJECT-TYPE SYNTAX INTEGER { forceModeValue(2) , notAvailable(3) , ac10Mbps(10) , ac100Mbps(100) , ac1000Mbps(1000) } MAX-ACCESS read-only STATUS current DESCRIPTION " AC INI-Param: N/A" ::= {acSysEthernet 2} acSysEthernetSecondPortDuplexMode OBJECT-TYPE SYNTAX INTEGER { halfDuplex(0) , fullDuplex(1) , forceModeValue(2) , notAvailable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "full-duplex or half-duplex connection. AC INI-Param: N/A" ::= {acSysEthernet 3} acSysEthernetSecondPortSpeed OBJECT-TYPE SYNTAX INTEGER { forceModeValue(2) , notAvailable(3) , ac10Mbps(10) , ac100Mbps(100) , ac1000Mbps(1000) } MAX-ACCESS read-only STATUS current DESCRIPTION " AC INI-Param: N/A" ::= {acSysEthernet 4} acSysEthernetActivePortNumber OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS read-only STATUS current DESCRIPTION "Display the current active ethernet port number. 0 - not relevant. AC INI-Param: N/A" ::= {acSysEthernet 5} acSysEthernetPowerBudget OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Display the availbale power budget for the system. AC INI-Param: N/A" ::= {acSysEthernet 6} acSysEthernetPowerAllocated OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Display the allocated power in the system. AC INI-Param: N/A" ::= {acSysEthernet 7} acSysEthernetPowerRemaining OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Display the availbale remaining power in the system. AC INI-Param: N/A" ::= {acSysEthernet 8} -- **************************************** -- acSysEthernetStatus table declaration -- **************************************** acSysEthernetStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysEthernetStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Ethernet relevant information" ::= {acSysEthernet 21} -- **************************************** -- acSysEthernetStatus table entry -- **************************************** acSysEthernetStatusEntry OBJECT-TYPE SYNTAX AcSysEthernetStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysEthernetStatusIndex} ::= {acSysEthernetStatusTable 1} -- **************************************** -- acSysEthernetStatus TABLE -- **************************************** AcSysEthernetStatusEntry ::= SEQUENCE { acSysEthernetStatusIndex Unsigned32, acSysEthernetStatusPortDuplexMode INTEGER, acSysEthernetStatusPortSpeed INTEGER, acSysEthernetStatusActivePortNumber INTEGER, acSysEthernetStatusPortState INTEGER, acSysEthernetStatusPowerOverEthernet INTEGER, acSysEthernetStatusAllocatedPower SnmpAdminString, acSysEthernetStatusGroup SnmpAdminString, acSysEthernetStatusPowerOverEthernetDetails SnmpAdminString } acSysEthernetStatusIndex OBJECT-TYPE SYNTAX Unsigned32 (1..12) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The row's index. On 8410 Systems: Index 1 – related to GBE port no.1 in the TER (Media). Index 2 – related to GBE port no.2 in the TER (Media). Index 3 – related to port 1A in PEM #1 (Control). Index 4 – related to port 1B in PEM #2 (Control). Index 5 – related to port 2A in PEM #1 (OAM). Index 6 – related to port 2B in PEM #2 (OAM). On MSBG only: 1-12 LAN interfaces. AC INI-Param: N/A" ::= {acSysEthernetStatusEntry 1} acSysEthernetStatusPortDuplexMode OBJECT-TYPE SYNTAX INTEGER { halfDuplex(0) , fullDuplex(1) , forceModeValue(2) , notAvailable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "full-duplex or half-duplex connection. AC INI-Param: N/A" ::= {acSysEthernetStatusEntry 2} acSysEthernetStatusPortSpeed OBJECT-TYPE SYNTAX INTEGER { forceModeValue(2) , notAvailable(3) , ac10Mbps(10) , ac100Mbps(100) , ac1000Mbps(1000) , ac10Gbps(10000) } MAX-ACCESS read-only STATUS current DESCRIPTION "port speed. AC INI-Param: N/A" ::= {acSysEthernetStatusEntry 3} acSysEthernetStatusActivePortNumber OBJECT-TYPE SYNTAX INTEGER { notActive(0) , active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of ethernet port - active or not active. AC INI-Param: N/A" ::= {acSysEthernetStatusEntry 4} acSysEthernetStatusPortState OBJECT-TYPE SYNTAX INTEGER { disabled(0) , blocking(1) , learning(2) , forwarding(3) , notApplicable(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "Port State. AC INI-Param: N/A" ::= {acSysEthernetStatusEntry 5} acSysEthernetStatusPowerOverEthernet OBJECT-TYPE SYNTAX INTEGER { notApplicable(0) , active(1) , notActive(2) , poeAlarm(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Power over Ethernet interface status. AC INI-Param: N/A" ::= {acSysEthernetStatusEntry 6} acSysEthernetStatusAllocatedPower OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "Power consumed by the port. AC INI-Param: N/A" ::= {acSysEthernetStatusEntry 7} acSysEthernetStatusGroup OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "The group which the port is a member of. AC INI-Param: N/A" ::= {acSysEthernetStatusEntry 8} acSysEthernetStatusPowerOverEthernetDetails OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..100)) MAX-ACCESS read-only STATUS current DESCRIPTION "Power over Ethernet interface status details. AC INI-Param: N/A" ::= {acSysEthernetStatusEntry 9} -- **************************************** -- acSysWanStatus table declaration -- **************************************** acSysWanStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysWanStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Ethernet relevant information" ::= {acSysEthernet 22} -- **************************************** -- acSysWanStatus table entry -- **************************************** acSysWanStatusEntry OBJECT-TYPE SYNTAX AcSysWanStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysWanStatusIndex} ::= {acSysWanStatusTable 1} -- **************************************** -- acSysWanStatus TABLE -- **************************************** AcSysWanStatusEntry ::= SEQUENCE { acSysWanStatusIndex Unsigned32, acSysWanStatusPortType INTEGER, acSysWanStatusPortDuplexMode INTEGER, acSysWanStatusPortSpeed INTEGER, acSysWanStatusActivePortNumber INTEGER, acSysWanStatusPortState INTEGER, acSysWanStatusPowerOverEthernet INTEGER } acSysWanStatusIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The row's index. On MSBG Only. AC INI-Param: N/A" ::= {acSysWanStatusEntry 1} acSysWanStatusPortType OBJECT-TYPE SYNTAX INTEGER { ethernet(0) , t1(1) , sHDSL(2) , adslVdsl(3) , invalidPhyType(4) } MAX-ACCESS read-only STATUS current DESCRIPTION " AC INI-Param: N/A" ::= {acSysWanStatusEntry 2} acSysWanStatusPortDuplexMode OBJECT-TYPE SYNTAX INTEGER { halfDuplex(0) , fullDuplex(1) , forceModeValue(2) , notAvailable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "full-duplex or half-duplex connection. AC INI-Param: N/A" ::= {acSysWanStatusEntry 3} acSysWanStatusPortSpeed OBJECT-TYPE SYNTAX INTEGER { forceModeValue(2) , notAvailable(3) , ac10Mbps(10) , ac100Mbps(100) , ac1000Mbps(1000) } MAX-ACCESS read-only STATUS current DESCRIPTION "port speed. AC INI-Param: N/A" ::= {acSysWanStatusEntry 4} acSysWanStatusActivePortNumber OBJECT-TYPE SYNTAX INTEGER { notActive(0) , active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of ethernet port - active or not active. AC INI-Param: N/A" ::= {acSysWanStatusEntry 5} acSysWanStatusPortState OBJECT-TYPE SYNTAX INTEGER { disabled(0) , blocking(1) , learning(2) , forwarding(3) , notApplicable(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "Port State. AC INI-Param: N/A" ::= {acSysWanStatusEntry 6} acSysWanStatusPowerOverEthernet OBJECT-TYPE SYNTAX INTEGER { notApplicable(0) , active(1) , notActive(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Power over Ethernet interface status. AC INI-Param: N/A" ::= {acSysWanStatusEntry 7} -- **************************************** -- acSysEthernetRedundantStatus table declaration -- **************************************** acSysEthernetRedundantStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysEthernetRedundantStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Ethernet relevant information for redundant board (relevant for HA system). {@}Relevant only to M4K." ::= {acSysEthernet 23} -- **************************************** -- acSysEthernetRedundantStatus table entry -- **************************************** acSysEthernetRedundantStatusEntry OBJECT-TYPE SYNTAX AcSysEthernetRedundantStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysEthernetRedundantStatusIndex} ::= {acSysEthernetRedundantStatusTable 1} -- **************************************** -- acSysEthernetRedundantStatus TABLE -- **************************************** AcSysEthernetRedundantStatusEntry ::= SEQUENCE { acSysEthernetRedundantStatusIndex Unsigned32, acSysEthernetRedundantStatusPortDuplexMode INTEGER, acSysEthernetRedundantStatusPortSpeed INTEGER, acSysEthernetRedundantStatusActivePortNumber INTEGER, acSysEthernetRedundantStatusPortState INTEGER, acSysEthernetRedundantStatusPowerOverEthernet INTEGER, acSysEthernetRedundantStatusAllocatedPower SnmpAdminString, acSysEthernetRedundantStatusGroup SnmpAdminString, acSysEthernetRedundantStatusPowerOverEthernetDetails SnmpAdminString } acSysEthernetRedundantStatusIndex OBJECT-TYPE SYNTAX Unsigned32 (1..12) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The row's index. On MSBG only: 1-12 LAN interfaces. AC INI-Param: N/A" ::= {acSysEthernetRedundantStatusEntry 1} acSysEthernetRedundantStatusPortDuplexMode OBJECT-TYPE SYNTAX INTEGER { halfDuplex(0) , fullDuplex(1) , forceModeValue(2) , notAvailable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "full-duplex or half-duplex connection. AC INI-Param: N/A" ::= {acSysEthernetRedundantStatusEntry 2} acSysEthernetRedundantStatusPortSpeed OBJECT-TYPE SYNTAX INTEGER { forceModeValue(2) , notAvailable(3) , ac10Mbps(10) , ac100Mbps(100) , ac1000Mbps(1000) } MAX-ACCESS read-only STATUS current DESCRIPTION "port speed. AC INI-Param: N/A" ::= {acSysEthernetRedundantStatusEntry 3} acSysEthernetRedundantStatusActivePortNumber OBJECT-TYPE SYNTAX INTEGER { notActive(0) , active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of ethernet port - active or not active. AC INI-Param: N/A" ::= {acSysEthernetRedundantStatusEntry 4} acSysEthernetRedundantStatusPortState OBJECT-TYPE SYNTAX INTEGER { disabled(0) , blocking(1) , learning(2) , forwarding(3) , notApplicable(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "Port State. AC INI-Param: N/A" ::= {acSysEthernetRedundantStatusEntry 5} acSysEthernetRedundantStatusPowerOverEthernet OBJECT-TYPE SYNTAX INTEGER { notApplicable(0) , active(1) , notActive(2) , poeAlarm(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Power over Ethernet interface status. AC INI-Param: N/A" ::= {acSysEthernetRedundantStatusEntry 6} acSysEthernetRedundantStatusAllocatedPower OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "Power consumed by the port. AC INI-Param: N/A" ::= {acSysEthernetRedundantStatusEntry 7} acSysEthernetRedundantStatusGroup OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "The group which the port is a member of. AC INI-Param: N/A" ::= {acSysEthernetRedundantStatusEntry 8} acSysEthernetRedundantStatusPowerOverEthernetDetails OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..100)) MAX-ACCESS read-only STATUS current DESCRIPTION "Power over Ethernet interface status details. AC INI-Param: N/A" ::= {acSysEthernetRedundantStatusEntry 9} acSysNAT OBJECT IDENTIFIER ::= {acSysNetwork 2} acSysNATType OBJECT-TYPE SYNTAX INTEGER { stunDisabled(-1) , none(0) , fullCone(1) , restricted(2) , portRestricted(3) , symmetric(4) , symmetricFireWall(5) , blocked(6) , unknown(7) , natIdentificationInProgress(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "Identified NAT type. -1 - STUN client is disabled 0 - None 1 - FullCone 2 - Restricted 3 - PortRestricted 4 - Symmetric 5 - SymmetricFireWall 6 - Blocked 7 - Unknown 10 - NAT identification in progress. AC INI-Param: N/A" ::= {acSysNAT 1} acSysWebStat OBJECT IDENTIFIER ::= {acSysNetwork 3} acSysWebStatPasswordControlViaSNMP OBJECT-TYPE SYNTAX INTEGER { disabled(0) , enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "If set to 1 it will allow changing the web interface username and password via SNMP. AC INI-Param: WEBPasswordControlViaSNMP " ::= {acSysWebStat 1} acSysIPStatus OBJECT IDENTIFIER ::= {acSysNetwork 4} -- **************************************** -- acSysInterfaceStatus table declaration -- **************************************** acSysInterfaceStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysInterfaceStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acSysIPStatus 21} -- **************************************** -- acSysInterfaceStatus table entry -- **************************************** acSysInterfaceStatusEntry OBJECT-TYPE SYNTAX AcSysInterfaceStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysInterfaceStatusEntryIndex,acSysInterfaceStatusTypeIndex} ::= {acSysInterfaceStatusTable 1} -- **************************************** -- acSysInterfaceStatus TABLE -- **************************************** AcSysInterfaceStatusEntry ::= SEQUENCE { acSysInterfaceStatusEntryIndex Unsigned32, acSysInterfaceStatusTypeIndex Unsigned32, acSysInterfaceStatusApplicationTypes INTEGER, acSysInterfaceStatusMode INTEGER, acSysInterfaceStatusIPAddress SnmpAdminString, acSysInterfaceStatusPrefixLength Unsigned32, acSysInterfaceStatusGateway SnmpAdminString, acSysInterfaceStatusVlanID Unsigned32, acSysInterfaceStatusName SnmpAdminString } acSysInterfaceStatusEntryIndex OBJECT-TYPE SYNTAX Unsigned32 (0..31) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Related Interface index in the interface configuration table (in case the table is empty - meaning there is only single IP the index will appear with 0). AC INI-Param: N/A" ::= {acSysInterfaceStatusEntry 1} acSysInterfaceStatusTypeIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION " 1 - IP Address. 2 - IPv6 Link-Local Address. AC INI-Param: N/A" ::= {acSysInterfaceStatusEntry 2} acSysInterfaceStatusApplicationTypes OBJECT-TYPE SYNTAX INTEGER { oam(0) , media(1) , control(2) , oamAndMedia(3) , oamAndControl(4) , mediaAndControl(5) , oamAndMediaAndControl(6) , data(11) , maintenance(99) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type assigned to the interface. AC INI-Param: N/A" ::= {acSysInterfaceStatusEntry 3} acSysInterfaceStatusMode OBJECT-TYPE SYNTAX INTEGER { iPv6PrefixManual(3) , iPv6Manual(4) , iPv4Manual(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "Interface configuration mode. AC INI-Param: N/A" ::= {acSysInterfaceStatusEntry 4} acSysInterfaceStatusIPAddress OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..45)) MAX-ACCESS read-only STATUS current DESCRIPTION "IP Address (can be either IPv4 or IPv6) for this interface. AC INI-Param: N/A" ::= {acSysInterfaceStatusEntry 5} acSysInterfaceStatusPrefixLength OBJECT-TYPE SYNTAX Unsigned32 (0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ‘1’ bits in this interface’s netmask. AC INI-Param: N/A" ::= {acSysInterfaceStatusEntry 6} acSysInterfaceStatusGateway OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..45)) MAX-ACCESS read-only STATUS current DESCRIPTION "Default Gateway. AC INI-Param: N/A" ::= {acSysInterfaceStatusEntry 7} acSysInterfaceStatusVlanID OBJECT-TYPE SYNTAX Unsigned32 (0..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "VLAN ID of this interface. AC INI-Param: N/A" ::= {acSysInterfaceStatusEntry 8} acSysInterfaceStatusName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "16 character string of this interface’s name. AC INI-Param: N/A" ::= {acSysInterfaceStatusEntry 9} -- **************************************** -- acSysDataInterfaceStatus table declaration -- **************************************** acSysDataInterfaceStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysDataInterfaceStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acSysIPStatus 22} -- **************************************** -- acSysDataInterfaceStatus table entry -- **************************************** acSysDataInterfaceStatusEntry OBJECT-TYPE SYNTAX AcSysDataInterfaceStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysDataInterfaceStatusIndex} ::= {acSysDataInterfaceStatusTable 1} -- **************************************** -- acSysDataInterfaceStatus TABLE -- **************************************** AcSysDataInterfaceStatusEntry ::= SEQUENCE { acSysDataInterfaceStatusIndex Unsigned32, acSysDataInterfaceStatusName SnmpAdminString, acSysDataInterfaceStatusIPAddress SnmpAdminString, acSysDataInterfaceStatusNetmask SnmpAdminString, acSysDataInterfaceStatusInfo SnmpAdminString, acSysDataInterfaceStatusDescription SnmpAdminString, acSysDataInterfaceStatusOperationalState INTEGER, acSysDataInterfaceStatusStateTime SnmpAdminString, acSysDataInterfaceStatusUptime SnmpAdminString, acSysDataInterfaceStatusMtuMode SnmpAdminString, acSysDataInterfaceStatusDnsStatus SnmpAdminString, acSysDataInterfaceStatusRxPackets Counter32, acSysDataInterfaceStatusRxBytes Counter32, acSysDataInterfaceStatusRxDropped Counter32, acSysDataInterfaceStatusRxErrors Counter32, acSysDataInterfaceStatusTxPackets Counter32, acSysDataInterfaceStatusTxBytes Counter32, acSysDataInterfaceStatusTxDropped Counter32, acSysDataInterfaceStatusTxErrors Counter32, acSysDataInterfaceStatusMinutes Unsigned32, acSysDataInterfaceStatusMinuteInputRate SnmpAdminString, acSysDataInterfaceStatusMinuteOutputRate SnmpAdminString, acSysDataInterfaceStatusSeconds Unsigned32, acSysDataInterfaceStatusSecondInputRate SnmpAdminString, acSysDataInterfaceStatusSecondOutputRate SnmpAdminString } acSysDataInterfaceStatusIndex OBJECT-TYPE SYNTAX Unsigned32 (0..69) MAX-ACCESS not-accessible STATUS current DESCRIPTION " AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 1} acSysDataInterfaceStatusName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..70)) MAX-ACCESS read-only STATUS current DESCRIPTION "Interface name. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 2} acSysDataInterfaceStatusIPAddress OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..45)) MAX-ACCESS read-only STATUS current DESCRIPTION "IPv4 Address for this interface. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 3} acSysDataInterfaceStatusNetmask OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..45)) MAX-ACCESS read-only STATUS current DESCRIPTION "Netmask for this interface. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 4} acSysDataInterfaceStatusInfo OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..30)) MAX-ACCESS read-only STATUS current DESCRIPTION "Status of interface can be one of the following: Unknown, Disabled, Enabled, Connected or Disconnected. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 5} acSysDataInterfaceStatusDescription OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..30)) MAX-ACCESS read-only STATUS current DESCRIPTION "Description of the interface. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 6} acSysDataInterfaceStatusOperationalState OBJECT-TYPE SYNTAX INTEGER { down(0) , up(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Protocol is UP or Down. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 7} acSysDataInterfaceStatusStateTime OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..9)) MAX-ACCESS read-only STATUS current DESCRIPTION "Time elapsed since the interface entered its current state (HH:MM:SS). AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 8} acSysDataInterfaceStatusUptime OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..9)) MAX-ACCESS read-only STATUS current DESCRIPTION "Time since the interface was created (HH:MM:SS). AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 9} acSysDataInterfaceStatusMtuMode OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "the Maximum Transmission Unit (MTU) on the specified interface. Can be: automatically, DHCP or value (in bytes). AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 10} acSysDataInterfaceStatusDnsStatus OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "DNS servers information for this interface. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 11} acSysDataInterfaceStatusRxPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total packets received. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 12} acSysDataInterfaceStatusRxBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total bytes received. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 13} acSysDataInterfaceStatusRxDropped OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "No space in receive buffers available. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 14} acSysDataInterfaceStatusRxErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Bad packets received. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 15} acSysDataInterfaceStatusTxPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total packets transmitted. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 16} acSysDataInterfaceStatusTxBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total bytes transmitted. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 17} acSysDataInterfaceStatusTxDropped OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "No space in transmit buffers available. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 18} acSysDataInterfaceStatusTxErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Packet transmit problems. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 19} acSysDataInterfaceStatusMinutes OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This value determines time interval in minutes, on which the rate sampling is done. The value is relevant to the columns MinuteInputRate and MinuteOutputRate. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 20} acSysDataInterfaceStatusMinuteInputRate OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..100)) MAX-ACCESS read-only STATUS current DESCRIPTION "The average received bits rate (bps) and packets rate (pps) during the last ‘acSysDataInterfaceStatusMinutes’ minutes. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 21} acSysDataInterfaceStatusMinuteOutputRate OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..100)) MAX-ACCESS read-only STATUS current DESCRIPTION "The average transmitted bits rate (bps) and packets rate (pps) during the last ‘acSysDataInterfaceStatusMinutes’ minutes. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 22} acSysDataInterfaceStatusSeconds OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This value determines time interval in seconds on which the rate sampling is done. The value is relevant to the columns SecondInputRate and SecondOutputRate. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 23} acSysDataInterfaceStatusSecondInputRate OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..100)) MAX-ACCESS read-only STATUS current DESCRIPTION "The average received bits rate (bps) and packets rate (pps) during the last ‘acSysDataInterfaceStatusSeconds’ seconds. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 24} acSysDataInterfaceStatusSecondOutputRate OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..100)) MAX-ACCESS read-only STATUS current DESCRIPTION "The average transmitted bits rate (bps) and packets rate (pps) during the last ‘acSysDataInterfaceStatusSeconds’ seconds. AC INI-Param: N/A" ::= {acSysDataInterfaceStatusEntry 25} acSysTime OBJECT IDENTIFIER ::= {acSystemStatus 7} acSysTimeUp OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Time (in Seconds) that the board is alive. AC INI-Param: N/A" ::= {acSysTime 1} acSysVoicePrompt OBJECT IDENTIFIER ::= {acSystemStatus 8} acSysVoicePromptTotalMemorySize OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Get the total voice prompt memory size. AC INI-Param: N/A" ::= {acSysVoicePrompt 1} acSysVoicePromptMaxFreeMemorySize OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Get the maximu voice prompt memory free size. AC INI-Param: N/A" ::= {acSysVoicePrompt 2} acSysRepositoryAMS OBJECT IDENTIFIER ::= {acSystemStatus 9} acSysRepositoryAMSIsReadyForUpdate OBJECT-TYPE SYNTAX INTEGER { false(0) , true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Verify if the old repository is free or there are signals still using it. AC INI-Param: N/A" ::= {acSysRepositoryAMS 1} acSysHAStatus OBJECT IDENTIFIER ::= {acSystemStatus 10} acSysHAStatusReady OBJECT-TYPE SYNTAX INTEGER { notApplicable(1) , yes(2) , no(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Defines whether the M3K system supports HA or not. AC INI-Param: N/A" ::= {acSysHAStatus 1} acSysHAStatusNetworkWatchdogStatus OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..400)) MAX-ACCESS read-only STATUS current DESCRIPTION " AC INI-Param: N/A" ::= {acSysHAStatus 2} acSysLDAPStatus OBJECT IDENTIFIER ::= {acSystemStatus 11} acSysLDAPStatusServerMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(0) , connectionBroken(1) , connecting(2) , connected(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "LDAP server status. AC INI-Param: N/A" ::= {acSysLDAPStatus 1} acSysNqmStatus OBJECT IDENTIFIER ::= {acSystemStatus 12} -- **************************************** -- acSysNqmHistory table declaration -- **************************************** acSysNqmHistoryTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysNqmHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acSysNqmStatus 1} -- **************************************** -- acSysNqmHistory table entry -- **************************************** acSysNqmHistoryEntry OBJECT-TYPE SYNTAX AcSysNqmHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysNqmHistorySenderIndex,acSysNqmHistoryIndex} ::= {acSysNqmHistoryTable 1} -- **************************************** -- acSysNqmHistory TABLE -- **************************************** AcSysNqmHistoryEntry ::= SEQUENCE { acSysNqmHistorySenderIndex Unsigned32, acSysNqmHistoryIndex Unsigned32, acSysNqmHistoryProbeTime SnmpAdminString, acSysNqmHistoryIsValid SnmpAdminString, acSysNqmHistoryRoundTripTime Unsigned32, acSysNqmHistoryPacketLossTx Unsigned32, acSysNqmHistoryPacketLossRx Unsigned32, acSysNqmHistoryTotalPacketLoss Unsigned32, acSysNqmHistoryJitterTx Unsigned32, acSysNqmHistoryJitterRx Unsigned32, acSysNqmHistoryTotalJitter Unsigned32, acSysNqmHistoryCqMos Unsigned32, acSysNqmHistoryLqMos Unsigned32 } acSysNqmHistorySenderIndex OBJECT-TYPE SYNTAX Unsigned32 (0..9) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of Sender from acSysNqmSenderTable. AC INI-Param: N/A" ::= {acSysNqmHistoryEntry 1} acSysNqmHistoryIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Internal index. AC INI-Param: N/A" ::= {acSysNqmHistoryEntry 2} acSysNqmHistoryProbeTime OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "NULL terminated. AC INI-Param: N/A" ::= {acSysNqmHistoryEntry 3} acSysNqmHistoryIsValid OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "Null terminated Yes/No or textual reason. AC INI-Param: N/A" ::= {acSysNqmHistoryEntry 4} acSysNqmHistoryRoundTripTime OBJECT-TYPE SYNTAX Unsigned32 (0..99999) MAX-ACCESS read-only STATUS current DESCRIPTION "round trip time [msec]. AC INI-Param: N/A" ::= {acSysNqmHistoryEntry 5} acSysNqmHistoryPacketLossTx OBJECT-TYPE SYNTAX Unsigned32 (0..999999) MAX-ACCESS read-only STATUS current DESCRIPTION "outging packet loss. AC INI-Param: N/A" ::= {acSysNqmHistoryEntry 6} acSysNqmHistoryPacketLossRx OBJECT-TYPE SYNTAX Unsigned32 (0..999999) MAX-ACCESS read-only STATUS current DESCRIPTION "incoming packet loss. AC INI-Param: N/A" ::= {acSysNqmHistoryEntry 7} acSysNqmHistoryTotalPacketLoss OBJECT-TYPE SYNTAX Unsigned32 (0..9999999) MAX-ACCESS read-only STATUS current DESCRIPTION "sum of Rx and Tx packet loss. AC INI-Param: N/A" ::= {acSysNqmHistoryEntry 8} acSysNqmHistoryJitterTx OBJECT-TYPE SYNTAX Unsigned32 (0..999999) MAX-ACCESS read-only STATUS current DESCRIPTION "outgoing jitter. AC INI-Param: N/A" ::= {acSysNqmHistoryEntry 9} acSysNqmHistoryJitterRx OBJECT-TYPE SYNTAX Unsigned32 (0..999999) MAX-ACCESS read-only STATUS current DESCRIPTION "incoming jitter. AC INI-Param: N/A" ::= {acSysNqmHistoryEntry 10} acSysNqmHistoryTotalJitter OBJECT-TYPE SYNTAX Unsigned32 (0..9999999) MAX-ACCESS read-only STATUS current DESCRIPTION "round trip jitter. AC INI-Param: N/A" ::= {acSysNqmHistoryEntry 11} acSysNqmHistoryCqMos OBJECT-TYPE SYNTAX Unsigned32 (0..99999) MAX-ACCESS read-only STATUS current DESCRIPTION "Conversation quality MOS. AC INI-Param: N/A" ::= {acSysNqmHistoryEntry 12} acSysNqmHistoryLqMos OBJECT-TYPE SYNTAX Unsigned32 (0..99999) MAX-ACCESS read-only STATUS current DESCRIPTION "Listener quality MOS. AC INI-Param: N/A" ::= {acSysNqmHistoryEntry 13} acSysDataStatus OBJECT IDENTIFIER ::= {acSystemStatus 13} acSysDataStatusFirewallTCPConnections OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of TCP firewall connections. AC INI-Param: N/A" ::= {acSysDataStatus 1} acSysDataStatusFirewallUDPConnections OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of UDP firewall connections. AC INI-Param: N/A" ::= {acSysDataStatus 2} acSysDataStatusFirewallICMPConnections OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ICMP firewall connections. AC INI-Param: N/A" ::= {acSysDataStatus 3} acSystemAction OBJECT IDENTIFIER ::= {acSystem 3} acSysAction OBJECT IDENTIFIER ::= {acSystemAction 1} acSysActionSet OBJECT IDENTIFIER ::= {acSysAction 1} acSysActionSetReset OBJECT-TYPE SYNTAX Unsigned32 (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "remote Reset. To remote reset the board, set the value of this object to 1. Note: Before Reset, The current boardConfiguration parameters will be burned to the board. Access: Instant. AC INI-Param: N/A" ::= {acSysActionSet 1} acSysActionSetResetControl OBJECT-TYPE SYNTAX INTEGER { resetFromFlashAfterBurn(1) , resetFromFlashNoBurn(2) , resetFromBootP(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the remote reset action. 1 - burn staged load image, if any, and config to flash, perform a reset, and load from flash 2 - perform a reset, and load from flash (staged load image, if any, and config is not burned to flash) 3 - perform a reset, and load from bootp/tftp (staged load image, if any, and config burn is not needed) * - an error is returned for any other value Note: The staged load image is an image of a cmp file that was previously loaded to a area in RAM via an HTTP upload. Access: Instant. AC INI-Param: RemoteResetControl" ::= {acSysActionSet 2} acSysActionSetDefaults OBJECT-TYPE SYNTAX Unsigned32 (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "To set the board to default values, set the value of this object to 1. Access: Instant. AC INI-Param: N/A" ::= {acSysActionSet 3} acSysActionSetSaveConfig OBJECT-TYPE SYNTAX Unsigned32 (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "To save all current configuration in the board onto the flash, set the value of this object to 1. NOTE: Do NOT save the configuration while voice is running - this will cause a delay. Access: Instant. AC INI-Param: N/A" ::= {acSysActionSet 4} acSysActionSetAutoUpdate OBJECT-TYPE SYNTAX Unsigned32 (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "To update the system configuration according to the provisioned IniFileUrl, set the value of this object to 1. Access: Instant. AC INI-Param: N/A" ::= {acSysActionSet 5} acSysActionSetGetTimeFromNTPServer OBJECT-TYPE SYNTAX Unsigned32 (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Initiates an immediate NTP time fetch. Access: Instant. AC INI-Param: N/A" ::= {acSysActionSet 6} acSysActionSetSwUpgrade OBJECT-TYPE SYNTAX INTEGER { hitLessUpGrade(1) , systemResetUpGrade(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the type of SW upgrade in M3K HA system: Hitless upgrade only or system reset upgrade if hitless is not supported. This parameter can be set by ini file and snmp. Access: Instant. AC INI-Param: M3KHASwUpgradeMode" ::= {acSysActionSet 7} acSysActionSetOnLineChangesApply OBJECT-TYPE SYNTAX INTEGER { defaultValue(0) , applyChanges(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applies the board on line changed params. Access: Instant. AC INI-Param: N/A" ::= {acSysActionSet 8} acSysActionSetIPSecTLSUpgrade OBJECT-TYPE SYNTAX INTEGER { defaultValue(0) , upDateChanges(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "To update the IPSec TLS configuration according to the provisioned TLS fils URL set the value of this object to 1. Access: Instant. AC INI-Param: N/A" ::= {acSysActionSet 9} acSysActionSetGWAppTLSUpgrade OBJECT-TYPE SYNTAX INTEGER { defaultValue(0) , upDateChanges(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "To update the GWApp TLS configuration according to the provisioned TLS fils URL set the value of this object to 1. Access: Instant. AC INI-Param: N/A" ::= {acSysActionSet 10} acSysActionSetConvertNetworkIFsConfiguration OBJECT-TYPE SYNTAX INTEGER { defaultValue(0) , convertAction(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "SET to 1 will convert network configuration to advance multiple network Interfaces mode. Access: Instant. AC INI-Param: N/A" ::= {acSysActionSet 11} acSysActionSetActionId OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "This field is for management use and is aimed to distinguish different managers managing a single device. Access: Instant. AC INI-Param: N/A" ::= {acSysActionSet 12} acSysActionSetAutoUpdateActionResult OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..200)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the autoupdates operation status in the form of a string: 'acSysActionId ; ; '. The status field can be: 'success'\'failure'\'inProgress'. The infromation is valid only when downloading one file at a time. Note - a second way of following the success of the file downloading is to see the files name being updated in the acSysFile subtree. AC INI-Param: N/A" ::= {acSysActionSet 13} acSysActionSetApplyINImethod OBJECT-TYPE SYNTAX INTEGER { applyAfterReset(0) , applyImmediate(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "INI parsing method. 0 = Apply After Reset 1 = Apply Immediate When downloading a new INI to the gateway this parameter determine if a parsing will be done immediately or after a reboot. Note that the default is immediately parsing. Access: Instant. AC INI-Param: ApplyINImethod" ::= {acSysActionSet 14} acSysActionAdmin OBJECT IDENTIFIER ::= {acSysAction 2} acSysActionAdminState OBJECT-TYPE SYNTAX INTEGER { locked(0) , shuttingDown(1) , unlocked(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the gateway's operational state. 0 - locked: Shutdown the GW In the time frame set by acgwAdminStateLockControl. 1 - shuttingDown: (read only) Graceful Shutdown is being carried out. 2 - unlocked: GW is in service. Access: Online. AC INI-Param: N/A" ::= {acSysActionAdmin 1} acSysActionAdminStateLockTimeout OBJECT-TYPE SYNTAX Integer32 (-1..32768) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the time remaining (in seconds) for the shutdown to complete. 0 = immediate shutdown -1 = waits until all calls drop (infinite) >0 = the number of seconds to wait. Access: Offline. AC INI-Param: N/A" ::= {acSysActionAdmin 2} acSysUpload OBJECT IDENTIFIER ::= {acSysAction 3} acSysUploadActionType OBJECT-TYPE SYNTAX INTEGER { none(0) , upload(1) , remove(2) , actionDone(10) } MAX-ACCESS read-write STATUS current DESCRIPTION "Action to be carried out. Setting this field triggers the action. File upload supported for iniFile(1), v5PortFile(16) and DataConfigurationFile(17) only access is instant. File removal supported for all other then iniFile(1), casFile(7), v5PortFile(16) and DataConfigurationFile(17), (v5PortFile removal is done via acV5PortActionType) access is offline. Access: Instant. AC INI-Param: N/A" ::= {acSysUpload 1} acSysUploadFileType OBJECT-TYPE SYNTAX INTEGER { iniFile(1) , cptFile(2) , vpFile(3) , prerecordedTonesFile(4) , fxsCoeffFile(5) , fxoCoeffFile(6) , casFile(7) , xmlFile(8) , externalCoderFile(9) , userInfoFile(10) , dialPlanFile(11) , tlsPKeyFile(12) , tlsCertFile(13) , tlsRootFile(14) , videoFontFile(15) , v5PortFile(16) , dataConfigurationFile(17) , amdSensitivityFile(18) } MAX-ACCESS read-write STATUS current DESCRIPTION "The file type to be uploaded. Note - for file types with more then one instance (like CAS files) use the acSysActionFileInstance to specify which instance you want to upload. Access: Instant. AC INI-Param: N/A" ::= {acSysUpload 2} acSysUploadFileNumber OBJECT-TYPE SYNTAX Integer32 (-1..7) MAX-ACCESS read-write STATUS current DESCRIPTION "File number for file types that have more then one file instance, such as CAS, VideoFont etc'. Access: Instant. AC INI-Param: N/A" ::= {acSysUpload 3} acSysUploadFileURI OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-write STATUS current DESCRIPTION "URI indicating file location to be downloaded to. Access: Instant. AC INI-Param: N/A" ::= {acSysUpload 4} acSysUploadActionID OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "This field is for management use and is aimed to distinguish different managers managing a single device. Access: Instant. AC INI-Param: N/A" ::= {acSysUpload 5} acSysUploadActionResult OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "Action result. Includes action status (success, failure or inProgress), action ID. AC INI-Param: N/A" ::= {acSysUpload 6} acSystemChassis OBJECT IDENTIFIER ::= {acSystem 4} acSystemChassisDryContactsOutStatus OBJECT-TYPE SYNTAX BITS { noAlarm(0) , criticalAlarm(1) , majorAlarm(2) , minorAlarm(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates current state of the alarm dry contacts – out signals (3 signals). This is a bit-map of possible conditions. AC INI-Param: N/A" ::= {acSystemChassis 1} acSystemChassisDryContactsInStatus OBJECT-TYPE SYNTAX BITS { noAlarm(0) , alarm1(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates current state of the alarm dry contacts - in signals (1 signals). The role of each input signal should be according to the customer's requirements. This is a bit-map of possible conditions. AC INI-Param: N/A" ::= {acSystemChassis 2} acSystemChassisLastChanged OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time a row is modified in any of the acSystemChassis subtree's objects. AC INI-Param: N/A" ::= {acSystemChassis 3} -- **************************************** -- acSysModule table declaration -- **************************************** acSysModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= {acSystemChassis 21} -- **************************************** -- acSysModule table entry -- **************************************** acSysModuleEntry OBJECT-TYPE SYNTAX AcSysModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysModuleIndex} ::= {acSysModuleTable 1} -- **************************************** -- acSysModule TABLE -- **************************************** AcSysModuleEntry ::= SEQUENCE { acSysModuleIndex Unsigned32, acSysModuleGeographicalPosition Unsigned32, acSysModuleType INTEGER, acSysModulePresence INTEGER, acSysModuleLicenseKeyList SnmpAdminString, acSysModuleSerialNumber Integer32, acSysModuleSWVersion SnmpAdminString, acSysModuleOperationalState INTEGER, acSysModuleHAStatus INTEGER, acSysModuleLEDs OCTET STRING, acSysModuleTemperature Integer32, acSysModuleActions INTEGER, acSysModuleFRUaction INTEGER, acSysModuleFRUstatus INTEGER, acSysModuleNumOfPorts Unsigned32, acSysModuleFirstPortNum Unsigned32 } acSysModuleIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Module number in the system. AC INI-Param: N/A" ::= {acSysModuleEntry 1} acSysModuleGeographicalPosition OBJECT-TYPE SYNTAX Unsigned32 (1..12) MAX-ACCESS read-only STATUS current DESCRIPTION "The slot number in the chassis. 1 being the bottom slot and so on. AC INI-Param: N/A" ::= {acSysModuleEntry 2} acSysModuleType OBJECT-TYPE SYNTAX INTEGER { acUnknown(0) , acTrunkPack-08(1) , acMediaPack-108(2) , acMediaPack-124(3) , acTrunkPack-1600(20) , acTPM1100(22) , acTrunkPack-260-IpMedia(23) , acTrunkPack-1610(24) , acMediaPack-104(25) , acMediaPack-102(26) , acTrunkPack-1610-SB(29) , acTrunkPack-1610-IpMedia(30) , acTrunkPack-MEDIANT2000(31) , acTrunkPack-STRETTO2000(32) , acTrunkPack-IPMServer2000(33) , acTrunkPack-2810(34) , acTrunkPack-260-UN-IpMedia (35) , acTrunkPack-260-IpMedia-30Ch(36) , acTrunkPack-260-IpMedia-60Ch(37) , acTrunkPack-260-IpMedia-120Ch(38) , acTrunkPack-260RT-IpMedia-30Ch(39) , acTrunkPack-260RT-IpMedia-60Ch(40) , acTrunkPack-260RT-IpMedia-120Ch(41) , acTrunkPack-260(42) , acTrunkPack-260-UN (43) , acTPM1100-PCM(44) , acTrunkPack-6310(45) , acTPM6300(46) , acMediant1000(47) , acIPMedia3000(48) , acMediant3000(49) , acStretto3000(50) , acTrunkPack-6310-IpMedia(51) , acTrunkPack-6310-SB(52) , acATP-1610(53) , acATP-260(54) , acATP-260-UN(55) , acMediaPack-118(56) , acMediaPack114(57) , acMediaPack112(58) , acTrunkPack-6310-T3(59) , acMediant3000-T3(60) , acIPmedia3000-T3(61) , acTrunkPack-6310-T3-IpMedia(62) , acTrunkPack-8410(63) , acTrunkPack-8410-IpMedia(64) , acMediant-800-MSBG(69) , acMediant-500-MSBR(76) , acMediant-500-ESBC(77) , acMediant-500L-MSBR(84) , acMediant-500L-ESBC(85) , sA1(250) , sA2(251) , sA3(252) , acMediant1000CPUmodule(253) , acMediant1000IFDigitalModule(254) , acMediant1000IFAnalogModule(255) , acMediant1000IFBRIModule(256) , acMediant1000IPMediaModule(257) , acMediant600CPUmodule(258) , acMediant600IFDigitalModule(259) , acMediant600IFAnalogModule(260) , acMediant600IFBRIModule(261) , acMediant600IPMediaModule(262) , acMediant800CPUmodule(265) , acMediant800IFDigitalModule(266) , acMediant800IFAnalogModule(267) , acMediant800IFBRIModule(268) , acMediant800IFWANModule(269) , acMediant800IFWiFiModule(270) , acMediant800IPMediaModule(271) , acMediant800EthernetModule(272) , acMediant800IFT1WANModule(273) , acMediant800IFSHDSLModule(274) , acMediant800IFADSLModule(275) , acMediant1000IFWANModule(276) , acMediant1000IFT1WANModule(277) , acMediant1000IFSHDSLModule(278) , acMediant1000IFADSLModule(279) , acMediant4000CPUmodule(280) , acMediant1000EthernetModule(281) , acSWESBCModule(282) , acMediant500CPUmodule(283) , acMediant500IFDigitalModule(284) , acMediant500IFAnalogModule(285) , acMediant500IFBRIModule(286) , acMediant500IFWANModule(287) , acMediant500IFWiFiModule(288) , acMediant500IPMediaModule(289) , acMediant500EthernetModule(290) , acMediant500IFT1WANModule(291) , acMediant500IFSHDSLModule(292) , acMediant500IFADSLModule(293) , acMediant500IFGESFPModule(294) , acMediant4000MPModule(295) , acMediant-850-MSBG(296) , acMediant850CPUmodule(297) , acMediant850IFDigitalModule(298) , acMediant850IFAnalogModule(299) , acMediant850IFBRIModule(300) , acMediant850IFWANModule(301) , acMediant850IFWiFiModule(302) , acMediant850IPMediaModule(303) , acMediant850EthernetModule(304) , acMediant850IFT1WANModule(305) , acMediant850IFSHDSLModule(306) , acMediant850IFADSLModule(307) , acMediant2600CPUmodule(308) , acMediant2600MPModule(309) } MAX-ACCESS read-only STATUS current DESCRIPTION "The module's type. AC INI-Param: N/A" ::= {acSysModuleEntry 3} acSysModulePresence OBJECT-TYPE SYNTAX INTEGER { present(1) , missing(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Is the module present or missing. AC INI-Param: N/A" ::= {acSysModuleEntry 4} acSysModuleLicenseKeyList OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..1400)) MAX-ACCESS read-only STATUS current DESCRIPTION "List of active features as enabled by the license key. SA modules return NULL. AC INI-Param: N/A" ::= {acSysModuleEntry 5} acSysModuleSerialNumber OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The module's serial number. For 6310 the serial number is the decimal form of the last 5 characters in the MAC Address. SA modules return 0. When the modules in the table are unavailable for audit (no HA) (-1) is returned. AC INI-Param: N/A" ::= {acSysModuleEntry 6} acSysModuleSWVersion OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "The version of the SW being run in the module placed . SA Modules return NULL. AC INI-Param: N/A" ::= {acSysModuleEntry 7} acSysModuleOperationalState OBJECT-TYPE SYNTAX INTEGER { disable(1) , enable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operational state of the module. Determined internally by the system. AC INI-Param: N/A" ::= {acSysModuleEntry 8} acSysModuleHAStatus OBJECT-TYPE SYNTAX INTEGER { acitveNonHA(1) , active(2) , redundant(3) , standAlone(4) , redundantNonHA(5) , notApplicable(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Modules status with in the system. Designed to define the HA state. AC INI-Param: N/A" ::= {acSysModuleEntry 9} acSysModuleLEDs OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..50)) MAX-ACCESS read-only STATUS current DESCRIPTION "Bit Field for the LEDs on the front of the module. LSB in each nibble (half Byte) is 0 - constant, 1 - blinking. 3 MSB are the color - 0 - none 1- Green 2 - Red 3 - Yellow 4 - Orange 5 - Blue 7 - Gray (unknown). AC INI-Param: N/A" ::= {acSysModuleEntry 10} acSysModuleTemperature OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of the board in degrees Celsius. SA Modules return 0. AC INI-Param: N/A" ::= {acSysModuleEntry 11} acSysModuleActions OBJECT-TYPE SYNTAX INTEGER { reset(1) , switchOver(2) , actionDone(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Actions to be performed by the module. Access: Instant. AC INI-Param: N/A" ::= {acSysModuleEntry 12} acSysModuleFRUaction OBJECT-TYPE SYNTAX INTEGER { fruActionDone(1) , fruOutOfServiceAction(2) , fruBackToServiceAction(3) , fruNotApplicable(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Field Replace Unit actions Relevant to IF-Module only. Access: Instant. AC INI-Param: N/A" ::= {acSysModuleEntry 13} acSysModuleFRUstatus OBJECT-TYPE SYNTAX INTEGER { moduleNotExist(1) , moduleExistOk(2) , moduleOutOfService(3) , moduleBackToServiceStart(4) , moduleMismatch(5) , moduleFaulty(6) , notApplicable(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Field Replace Unit module's status. AC INI-Param: N/A" ::= {acSysModuleEntry 14} acSysModuleNumOfPorts OBJECT-TYPE SYNTAX Unsigned32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical interfaces in a module, analog or digital. AC INI-Param: N/A" ::= {acSysModuleEntry 15} acSysModuleFirstPortNum OBJECT-TYPE SYNTAX Unsigned32 (0..19) MAX-ACCESS read-only STATUS current DESCRIPTION "The logical number as seen in the general trunk/analog-channel table of the first port in the module in question. Since analog and digital ports can be operational at once, analog and digital ports may have same logical number. AC INI-Param: N/A" ::= {acSysModuleEntry 16} -- **************************************** -- acSysFanTray table declaration -- **************************************** acSysFanTrayTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysFanTrayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acSystemChassis 22} -- **************************************** -- acSysFanTray table entry -- **************************************** acSysFanTrayEntry OBJECT-TYPE SYNTAX AcSysFanTrayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysFanTrayIndex} ::= {acSysFanTrayTable 1} -- **************************************** -- acSysFanTray TABLE -- **************************************** AcSysFanTrayEntry ::= SEQUENCE { acSysFanTrayIndex Unsigned32, acSysFanTrayGeographicalPosition Unsigned32, acSysFanTrayExistence INTEGER, acSysFanTrayType SnmpAdminString, acSysFanTrayLEDs OCTET STRING, acSysFanTraySeverity INTEGER, acSysFanTrayFansConfiguredSpeed OCTET STRING, acSysFanTrayFansCurrentSpeed OCTET STRING, acSysFanTrayFansStatus OCTET STRING } acSysFanTrayIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Fan-Tray's index in the system. AC INI-Param: N/A" ::= {acSysFanTrayEntry 1} acSysFanTrayGeographicalPosition OBJECT-TYPE SYNTAX Unsigned32 (1..1) MAX-ACCESS read-only STATUS current DESCRIPTION "The slot number in the chassis. AC INI-Param: N/A" ::= {acSysFanTrayEntry 2} acSysFanTrayExistence OBJECT-TYPE SYNTAX INTEGER { present(1) , missing(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Is the Fan-Tray present or missing. AC INI-Param: N/A" ::= {acSysFanTrayEntry 3} acSysFanTrayType OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..50)) MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the Fan-Tray . AC INI-Param: N/A" ::= {acSysFanTrayEntry 4} acSysFanTrayLEDs OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object built as a bit-field which represents the Fan-Tray's LEDs status. The first four bites represent the System's LED status and the last four bites represent the Shelf-LED’s status. AC INI-Param: N/A" ::= {acSysFanTrayEntry 5} acSysFanTraySeverity OBJECT-TYPE SYNTAX INTEGER { cleared(0) , indeterminate(1) , warning(2) , minor(3) , major(4) , critical(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Severity of the whole fan tray according to the current active alarm in the alarm table: Critical, Major or cleared. AC INI-Param: N/A" ::= {acSysFanTrayEntry 6} acSysFanTrayFansConfiguredSpeed OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The fan's configured speed in Tach units (RPM/120). Each Byte represents a fan. AC INI-Param: N/A" ::= {acSysFanTrayEntry 7} acSysFanTrayFansCurrentSpeed OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The fan's mesured speed in Tach units (RPM/120). Each Byte represents a fan. AC INI-Param: N/A" ::= {acSysFanTrayEntry 8} acSysFanTrayFansStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..1)) MAX-ACCESS read-only STATUS current DESCRIPTION "A bit field which display the working status of each fan in the Fan-Tray. 0 - Working 1 - Faulty. AC INI-Param: N/A" ::= {acSysFanTrayEntry 9} -- **************************************** -- acSysPowerSupply table declaration -- **************************************** acSysPowerSupplyTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysPowerSupplyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acSystemChassis 23} -- **************************************** -- acSysPowerSupply table entry -- **************************************** acSysPowerSupplyEntry OBJECT-TYPE SYNTAX AcSysPowerSupplyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysPowerSupplyIndex} ::= {acSysPowerSupplyTable 1} -- **************************************** -- acSysPowerSupply TABLE -- **************************************** AcSysPowerSupplyEntry ::= SEQUENCE { acSysPowerSupplyIndex Unsigned32, acSysPowerSupplyGeographicalPosition Unsigned32, acSysPowerSupplyExistence INTEGER, acSysPowerSupplyHwversion SnmpAdminString, acSysPowerSupplyLEDs OCTET STRING, acSysPowerSupplySeverity INTEGER } acSysPowerSupplyIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Power-Supply's index in the system. AC INI-Param: N/A" ::= {acSysPowerSupplyEntry 1} acSysPowerSupplyGeographicalPosition OBJECT-TYPE SYNTAX Unsigned32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "The slot number in the chassis. AC INI-Param: N/A" ::= {acSysPowerSupplyEntry 2} acSysPowerSupplyExistence OBJECT-TYPE SYNTAX INTEGER { present(1) , missing(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Is the Power-Supply present or missing. AC INI-Param: N/A" ::= {acSysPowerSupplyEntry 3} acSysPowerSupplyHwversion OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "PS’s HW version. AC INI-Param: N/A" ::= {acSysPowerSupplyEntry 4} acSysPowerSupplyLEDs OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "A bit-field representation of the Power-Supply LEDs' status. The first four bites represent the Power-Supply LED's status and the last four bites represent the Fault LED's status. AC INI-Param: N/A" ::= {acSysPowerSupplyEntry 5} acSysPowerSupplySeverity OBJECT-TYPE SYNTAX INTEGER { cleared(1) , indeterminate(2) , warning(3) , minor(4) , major(5) , critical(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Severity of the power-supply according to the current active alarm in the alarm table. AC INI-Param: N/A" ::= {acSysPowerSupplyEntry 6} -- **************************************** -- acSysPEM table declaration -- **************************************** acSysPEMTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysPEMEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acSystemChassis 24} -- **************************************** -- acSysPEM table entry -- **************************************** acSysPEMEntry OBJECT-TYPE SYNTAX AcSysPEMEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysPEMIndex} ::= {acSysPEMTable 1} -- **************************************** -- acSysPEM TABLE -- **************************************** AcSysPEMEntry ::= SEQUENCE { acSysPEMIndex Unsigned32, acSysPEMGeographicalPosition Unsigned32, acSysPEMExistence INTEGER, acSysPEMType SnmpAdminString, acSysPEMElectricWireConnection INTEGER } acSysPEMIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "PEM-Module's index in the system. AC INI-Param: N/A" ::= {acSysPEMEntry 1} acSysPEMGeographicalPosition OBJECT-TYPE SYNTAX Unsigned32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "The slot number in the chassis. AC INI-Param: N/A" ::= {acSysPEMEntry 2} acSysPEMExistence OBJECT-TYPE SYNTAX INTEGER { present(1) , missing(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Is the PEM-Module present or missing. AC INI-Param: N/A" ::= {acSysPEMEntry 3} acSysPEMType OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "PEM’s Type. AC INI-Param: N/A" ::= {acSysPEMEntry 4} acSysPEMElectricWireConnection OBJECT-TYPE SYNTAX INTEGER { connected(1) , disconnected(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Present the status of the electricity connector located on the PEM card. AC INI-Param: N/A" ::= {acSysPEMEntry 5} acSysSATModule OBJECT IDENTIFIER ::= {acSystemChassis 25} -- **************************************** -- acSysSAT table declaration -- **************************************** acSysSATTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysSATEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acSysSATModule 21} -- **************************************** -- acSysSAT table entry -- **************************************** acSysSATEntry OBJECT-TYPE SYNTAX AcSysSATEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysSATSatIndex} ::= {acSysSATTable 1} -- **************************************** -- acSysSAT TABLE -- **************************************** AcSysSATEntry ::= SEQUENCE { acSysSATSatIndex Unsigned32, acSysSATGeographicalPosition Unsigned32, acSysSATType SnmpAdminString, acSysSATInitInformation INTEGER, acSysSATTimingUnitExistence INTEGER, acSysSATTimingRefSelection INTEGER } acSysSATSatIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "SAT-Module's index in the system. AC INI-Param: N/A" ::= {acSysSATEntry 1} acSysSATGeographicalPosition OBJECT-TYPE SYNTAX Unsigned32 (2..4) MAX-ACCESS read-only STATUS current DESCRIPTION "The slot number in the chassis. AC INI-Param: N/A" ::= {acSysSATEntry 2} acSysSATType OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "SAT’s Type. AC INI-Param: N/A" ::= {acSysSATEntry 3} acSysSATInitInformation OBJECT-TYPE SYNTAX INTEGER { detected(0) , reConfig(1) , reConfigTry2(2) , reConfigTry3(3) , notInitialized(4) , initIsMissing(5) , initWasReset(6) , initFail(7) , initInProgress(8) , initUpdateREFTable(9) , remoteKeepAlive(10) , initComplete(11) } MAX-ACCESS read-only STATUS current DESCRIPTION "Sat's Init Information. AC INI-Param: N/A" ::= {acSysSATEntry 4} acSysSATTimingUnitExistence OBJECT-TYPE SYNTAX INTEGER { exist(1) , notExist(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Is the Timig Unit present or missing. AC INI-Param: N/A" ::= {acSysSATEntry 5} acSysSATTimingRefSelection OBJECT-TYPE SYNTAX INTEGER { bITSNOREF(0) , rEFFromBITSA(1) , rEFFromBITSB(2) , bITSNOREF1(3) , rEFFromLineClock1(4) , rEFFromLineClock2(5) , rEFFromLineClock3(6) , rEFFromLineClock7(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "SAT's Timing Reference Selection. AC INI-Param: N/A" ::= {acSysSATEntry 6} -- **************************************** -- acSysSATFramers table declaration -- **************************************** acSysSATFramersTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysSATFramersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acSysSATModule 22} -- **************************************** -- acSysSATFramers table entry -- **************************************** acSysSATFramersEntry OBJECT-TYPE SYNTAX AcSysSATFramersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysSATFramersSatIndex,acSysSATFramersFramerIndex} ::= {acSysSATFramersTable 1} -- **************************************** -- acSysSATFramers TABLE -- **************************************** AcSysSATFramersEntry ::= SEQUENCE { acSysSATFramersSatIndex Unsigned32, acSysSATFramersFramerIndex Unsigned32, acSysSATFramersFramerInterfaceStatus INTEGER, acSysSATFramersFramerLoopBackRef INTEGER, acSysSATFramersFramerInterfaceType INTEGER, acSysSATFramersFramerTransmitControl INTEGER, acSysSATFramersRxStatus INTEGER, acSysSATFramersIsUsedAsPLLClock INTEGER } acSysSATFramersSatIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "SAT-Module's index in the system. AC INI-Param: N/A" ::= {acSysSATFramersEntry 1} acSysSATFramersFramerIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Framer's Index. AC INI-Param: N/A" ::= {acSysSATFramersEntry 2} acSysSATFramersFramerInterfaceStatus OBJECT-TYPE SYNTAX INTEGER { framerInitialized(0) , framerNotInitialized(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Framer Interface Status. AC INI-Param: N/A" ::= {acSysSATFramersEntry 3} acSysSATFramersFramerLoopBackRef OBJECT-TYPE SYNTAX INTEGER { loopdisable(0) , loopenable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Frame rLoop Back Reference. AC INI-Param: N/A" ::= {acSysSATFramersEntry 4} acSysSATFramersFramerInterfaceType OBJECT-TYPE SYNTAX INTEGER { e1CRC4(0) , e1CAS(1) , e1FAS(2) , t1D4(3) , t1ESF(4) , t12(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Framer Interface Type. AC INI-Param: N/A" ::= {acSysSATFramersEntry 5} acSysSATFramersFramerTransmitControl OBJECT-TYPE SYNTAX INTEGER { systemClock(0) , aIS(1) , disableTransmit(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Framer Transmit Control. AC INI-Param: N/A" ::= {acSysSATFramersEntry 6} acSysSATFramersRxStatus OBJECT-TYPE SYNTAX INTEGER { alarmClear(0) , lOFAlarm(1) , lOSAlarm(2) , aISAlarm(3) , aISInit(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Provides the alarm status of the clock interface. AC INI-Param: N/A" ::= {acSysSATFramersEntry 7} acSysSATFramersIsUsedAsPLLClock OBJECT-TYPE SYNTAX INTEGER { notUsed(0) , used(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Is Used As PLL Clock indication. AC INI-Param: N/A" ::= {acSysSATFramersEntry 8} acSysTimingModule OBJECT IDENTIFIER ::= {acSystemChassis 26} -- **************************************** -- acSysPLLStatus table declaration -- **************************************** acSysPLLStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysPLLStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acSysTimingModule 21} -- **************************************** -- acSysPLLStatus table entry -- **************************************** acSysPLLStatusEntry OBJECT-TYPE SYNTAX AcSysPLLStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysPLLStatusIndex} ::= {acSysPLLStatusTable 1} -- **************************************** -- acSysPLLStatus TABLE -- **************************************** AcSysPLLStatusEntry ::= SEQUENCE { acSysPLLStatusIndex Unsigned32, acSysPLLStatusOperatingMode INTEGER } acSysPLLStatusIndex OBJECT-TYPE SYNTAX Unsigned32 (0..1) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table's Index. AC INI-Param: N/A" ::= {acSysPLLStatusEntry 1} acSysPLLStatusOperatingMode OBJECT-TYPE SYNTAX INTEGER { freeRun(0) , lockToRef1(1) , lockToRef2(2) , lockToLocal(3) , holdOver(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "PLL's Current Operating Mode. AC INI-Param: N/A" ::= {acSysPLLStatusEntry 2} acSystemChassisHA OBJECT IDENTIFIER ::= {acSystemChassis 27} acSystemChassisHADevice1Name OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "Define the unit identification name of the first unit of HA system. Relevant to M4K and SW-SBC. Access: Instant. AC INI-Param: HAUnitIdName" ::= {acSystemChassisHA 1} acSystemChassisHADevice2Name OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "Define the unit identification name of the second unit of HA system. Relevant to M4K and SW-SBC. Access: Instant. AC INI-Param: HAUnitIdName" ::= {acSystemChassisHA 2} acSystemChassisHAActiveDevice OBJECT-TYPE SYNTAX INTEGER { notApplicable(0) , device1(1) , device2(2) , standAlone(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the active device. Relevant to M4K and SW-SBC. AC INI-Param: N/A" ::= {acSystemChassisHA 3} -- **************************************** -- acSysRedundantModule table declaration -- **************************************** acSysRedundantModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysRedundantModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Relevant only to M4K." ::= {acSystemChassisHA 21} -- **************************************** -- acSysRedundantModule table entry -- **************************************** acSysRedundantModuleEntry OBJECT-TYPE SYNTAX AcSysRedundantModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysRedundantModuleIndex} ::= {acSysRedundantModuleTable 1} -- **************************************** -- acSysRedundantModule TABLE -- **************************************** AcSysRedundantModuleEntry ::= SEQUENCE { acSysRedundantModuleIndex Unsigned32, acSysRedundantModuleGeographicalPosition Unsigned32, acSysRedundantModuleType INTEGER, acSysRedundantModulePresence INTEGER, acSysRedundantModuleLicenseKeyList SnmpAdminString, acSysRedundantModuleSerialNumber Integer32, acSysRedundantModuleSWVersion SnmpAdminString, acSysRedundantModuleOperationalState INTEGER, acSysRedundantModuleHAStatus INTEGER, acSysRedundantModuleLEDs OCTET STRING, acSysRedundantModuleTemperature Integer32, acSysRedundantModuleActions INTEGER, acSysRedundantModuleFRUaction INTEGER, acSysRedundantModuleFRUstatus INTEGER, acSysRedundantModuleNumOfPorts Unsigned32, acSysRedundantModuleFirstPortNum Unsigned32 } acSysRedundantModuleIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Module number in the system. AC INI-Param: N/A" ::= {acSysRedundantModuleEntry 1} acSysRedundantModuleGeographicalPosition OBJECT-TYPE SYNTAX Unsigned32 (1..12) MAX-ACCESS read-only STATUS current DESCRIPTION "The CPU slot number of the redundant board. AC INI-Param: N/A" ::= {acSysRedundantModuleEntry 2} acSysRedundantModuleType OBJECT-TYPE SYNTAX INTEGER { acUnknown(0) , acMediant4000CPUmodule(280) , acMediant4000MPModule(295) , acMediant2600CPUmodule(308) , acMediant2600MPModule(309) } MAX-ACCESS read-only STATUS current DESCRIPTION "The module's type. AC INI-Param: N/A" ::= {acSysRedundantModuleEntry 3} acSysRedundantModulePresence OBJECT-TYPE SYNTAX INTEGER { present(1) , missing(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Is the module present or missing. AC INI-Param: N/A" ::= {acSysRedundantModuleEntry 4} acSysRedundantModuleLicenseKeyList OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..1400)) MAX-ACCESS read-only STATUS current DESCRIPTION "List of active features as enabled by the license key. SA modules return NULL. AC INI-Param: N/A" ::= {acSysRedundantModuleEntry 5} acSysRedundantModuleSerialNumber OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The module's serial number. For 6310 the serial number is the decimal form of the last 5 characters in the MAC Address. SA modules return 0. When the modules in the table are unavailable for audit (no HA) (-1) is returned. AC INI-Param: N/A" ::= {acSysRedundantModuleEntry 6} acSysRedundantModuleSWVersion OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "The version of the SW being run in the module placed . SA Modules return NULL. AC INI-Param: N/A" ::= {acSysRedundantModuleEntry 7} acSysRedundantModuleOperationalState OBJECT-TYPE SYNTAX INTEGER { disable(1) , enable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operational state of the module. Determined internally by the system. AC INI-Param: N/A" ::= {acSysRedundantModuleEntry 8} acSysRedundantModuleHAStatus OBJECT-TYPE SYNTAX INTEGER { acitveNonHA(1) , active(2) , redundant(3) , standAlone(4) , redundantNonHA(5) , notApplicable(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Modules status with in the system. Designed to define the HA state. AC INI-Param: N/A" ::= {acSysRedundantModuleEntry 9} acSysRedundantModuleLEDs OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..50)) MAX-ACCESS read-only STATUS current DESCRIPTION "Bit Field for the LEDs on the front of the module. LSB in each nibble (half Byte) is 0 - constant, 1 - blinking. 3 MSB are the color - 0 - none 1- Green 2 - Red 3 - Yellow 4 - Orange 5 - Blue 7 - Gray (unknown). AC INI-Param: N/A" ::= {acSysRedundantModuleEntry 10} acSysRedundantModuleTemperature OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of the board in degrees Celsius. SA Modules return 0. AC INI-Param: N/A" ::= {acSysRedundantModuleEntry 11} acSysRedundantModuleActions OBJECT-TYPE SYNTAX INTEGER { reset(1) , actionDone(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Actions to be performed by the module. Access: Instant. AC INI-Param: N/A" ::= {acSysRedundantModuleEntry 12} acSysRedundantModuleFRUaction OBJECT-TYPE SYNTAX INTEGER { fruActionDone(1) , fruOutOfServiceAction(2) , fruBackToServiceAction(3) , fruNotApplicable(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Field Replace Unit actions Relevant to IF-Module only. Access: Instant. AC INI-Param: N/A" ::= {acSysRedundantModuleEntry 13} acSysRedundantModuleFRUstatus OBJECT-TYPE SYNTAX INTEGER { moduleNotExist(1) , moduleExistOk(2) , moduleOutOfService(3) , moduleBackToServiceStart(4) , moduleMismatch(5) , moduleFaulty(6) , notApplicable(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Field Replace Unit module's status. AC INI-Param: N/A" ::= {acSysRedundantModuleEntry 14} acSysRedundantModuleNumOfPorts OBJECT-TYPE SYNTAX Unsigned32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of physical interfaces in a module, analog or digital. AC INI-Param: N/A" ::= {acSysRedundantModuleEntry 15} acSysRedundantModuleFirstPortNum OBJECT-TYPE SYNTAX Unsigned32 (0..19) MAX-ACCESS read-only STATUS current DESCRIPTION "The logical number as seen in the general trunk/analog-channel table of the first port in the module in question. Since analog and digital ports can be operational at once, analog and digital ports may have same logical number. AC INI-Param: N/A" ::= {acSysRedundantModuleEntry 16} -- **************************************** -- acSysRedundantFanTray table declaration -- **************************************** acSysRedundantFanTrayTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysRedundantFanTrayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Relevant only to M4K." ::= {acSystemChassisHA 22} -- **************************************** -- acSysRedundantFanTray table entry -- **************************************** acSysRedundantFanTrayEntry OBJECT-TYPE SYNTAX AcSysRedundantFanTrayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysRedundantFanTrayIndex} ::= {acSysRedundantFanTrayTable 1} -- **************************************** -- acSysRedundantFanTray TABLE -- **************************************** AcSysRedundantFanTrayEntry ::= SEQUENCE { acSysRedundantFanTrayIndex Unsigned32, acSysRedundantFanTrayGeographicalPosition Unsigned32, acSysRedundantFanTrayExistence INTEGER, acSysRedundantFanTrayType SnmpAdminString, acSysRedundantFanTrayLEDs OCTET STRING, acSysRedundantFanTraySeverity INTEGER, acSysRedundantFanTrayFansConfiguredSpeed OCTET STRING, acSysRedundantFanTrayFansCurrentSpeed OCTET STRING, acSysRedundantFanTrayFansStatus OCTET STRING } acSysRedundantFanTrayIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Fan-Tray's index in the system. AC INI-Param: N/A" ::= {acSysRedundantFanTrayEntry 1} acSysRedundantFanTrayGeographicalPosition OBJECT-TYPE SYNTAX Unsigned32 (1..1) MAX-ACCESS read-only STATUS current DESCRIPTION "The slot number in the chassis. AC INI-Param: N/A" ::= {acSysRedundantFanTrayEntry 2} acSysRedundantFanTrayExistence OBJECT-TYPE SYNTAX INTEGER { present(1) , missing(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Is the Fan-Tray present or missing. AC INI-Param: N/A" ::= {acSysRedundantFanTrayEntry 3} acSysRedundantFanTrayType OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..50)) MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the Fan-Tray . AC INI-Param: N/A" ::= {acSysRedundantFanTrayEntry 4} acSysRedundantFanTrayLEDs OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object built as a bit-field which represents the Fan-Tray's LEDs status. The first four bites represent the System's LED status and the last four bites represent the Shelf-LED’s status. AC INI-Param: N/A" ::= {acSysRedundantFanTrayEntry 5} acSysRedundantFanTraySeverity OBJECT-TYPE SYNTAX INTEGER { cleared(0) , indeterminate(1) , warning(2) , minor(3) , major(4) , critical(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Severity of the whole fan tray according to the current active alarm in the alarm table: Critical, Major or cleared. AC INI-Param: N/A" ::= {acSysRedundantFanTrayEntry 6} acSysRedundantFanTrayFansConfiguredSpeed OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The fan's configured speed in Tach units (RPM/120). Each Byte represents a fan. AC INI-Param: N/A" ::= {acSysRedundantFanTrayEntry 7} acSysRedundantFanTrayFansCurrentSpeed OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The fan's mesured speed in Tach units (RPM/120). Each Byte represents a fan. AC INI-Param: N/A" ::= {acSysRedundantFanTrayEntry 8} acSysRedundantFanTrayFansStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..1)) MAX-ACCESS read-only STATUS current DESCRIPTION "A bit field which display the working status of each fan in the Fan-Tray. 0 - Working 1 - Faulty. AC INI-Param: N/A" ::= {acSysRedundantFanTrayEntry 9} -- **************************************** -- acSysRedundantPowerSupply table declaration -- **************************************** acSysRedundantPowerSupplyTable OBJECT-TYPE SYNTAX SEQUENCE OF AcSysRedundantPowerSupplyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Relevant only to M4K." ::= {acSystemChassisHA 23} -- **************************************** -- acSysRedundantPowerSupply table entry -- **************************************** acSysRedundantPowerSupplyEntry OBJECT-TYPE SYNTAX AcSysRedundantPowerSupplyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acSysRedundantPowerSupplyIndex} ::= {acSysRedundantPowerSupplyTable 1} -- **************************************** -- acSysRedundantPowerSupply TABLE -- **************************************** AcSysRedundantPowerSupplyEntry ::= SEQUENCE { acSysRedundantPowerSupplyIndex Unsigned32, acSysRedundantPowerSupplyGeographicalPosition Unsigned32, acSysRedundantPowerSupplyExistence INTEGER, acSysRedundantPowerSupplyHwversion SnmpAdminString, acSysRedundantPowerSupplyLEDs OCTET STRING, acSysRedundantPowerSupplySeverity INTEGER } acSysRedundantPowerSupplyIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Power-Supply's index in the system. AC INI-Param: N/A" ::= {acSysRedundantPowerSupplyEntry 1} acSysRedundantPowerSupplyGeographicalPosition OBJECT-TYPE SYNTAX Unsigned32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "The slot number in the chassis. AC INI-Param: N/A" ::= {acSysRedundantPowerSupplyEntry 2} acSysRedundantPowerSupplyExistence OBJECT-TYPE SYNTAX INTEGER { present(1) , missing(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Is the Power-Supply present or missing. AC INI-Param: N/A" ::= {acSysRedundantPowerSupplyEntry 3} acSysRedundantPowerSupplyHwversion OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "PS’s HW version. AC INI-Param: N/A" ::= {acSysRedundantPowerSupplyEntry 4} acSysRedundantPowerSupplyLEDs OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "A bit-field representation of the Power-Supply LEDs' status. The first four bites represent the Power-Supply LED's status and the last four bites represent the Fault LED's status. AC INI-Param: N/A" ::= {acSysRedundantPowerSupplyEntry 5} acSysRedundantPowerSupplySeverity OBJECT-TYPE SYNTAX INTEGER { cleared(1) , indeterminate(2) , warning(3) , minor(4) , major(5) , critical(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Severity of the power-supply according to the current active alarm in the alarm table. AC INI-Param: N/A" ::= {acSysRedundantPowerSupplyEntry 6} END