-- --defines ROOMALERT11E-MIB for SNMP agent extension of Room Alert 11E --Contents: Global Registration Module -- Room Alert OIDs - Enterprise 20916 --Version: 1.1.3 --Date: 9 January 2014 --Developed By: AVTECH Software, Inc. -- --Copyright (c) 2014 AVTECH Software, Inc. -- ROOMALERT11E-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, IpAddress, Counter, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; avtech OBJECT IDENTIFIER ::= { enterprises 20916 } products OBJECT IDENTIFIER ::= { avtech 1 } roomalert11E OBJECT IDENTIFIER ::= { products 3 } sensors OBJECT IDENTIFIER ::= { roomalert11E 1 } traps OBJECT IDENTIFIER ::= { roomalert11E 2 } thresholds OBJECT IDENTIFIER ::= { roomalert11E 3 } channel1 OBJECT IDENTIFIER ::= { sensors 1 } channel2 OBJECT IDENTIFIER ::= { sensors 2 } channel3 OBJECT IDENTIFIER ::= { sensors 3 } channel4 OBJECT IDENTIFIER ::= { sensors 4 } channels OBJECT IDENTIFIER ::= { thresholds 1 } channels1 OBJECT IDENTIFIER ::= { channels 1 } channels2 OBJECT IDENTIFIER ::= { channels 2 } channels3 OBJECT IDENTIFIER ::= { channels 3 } channels4 OBJECT IDENTIFIER ::= { channels 4 } -- Room Alert 11E MIB -- Parameters sensor1-1 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for internal switch sensor 1 (0 = OPEN, 1 = CLOSED)." ::= { channel1 1 } sensor1-2 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for internal switch sensor 2 (0 = OPEN, 1 = CLOSED)." ::= { channel1 2 } sensor1-3 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for internal switch sensor 3 (0 = OPEN, 1 = CLOSED)." ::= { channel1 3 } sensor1-4 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for internal switch sensor 4 (0 = OPEN, 1 = CLOSED)." ::= { channel1 4 } sensor1-5 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for internal switch sensor 5 (0 = OPEN, 1 = CLOSED)." ::= { channel1 5 } sensor1-6 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for internal switch sensor 6 (0 = OPEN, 1 = CLOSED)." ::= { channel1 6 } sensor1-7 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for internal switch sensor 7 (0 = OPEN, 1 = CLOSED)." ::= { channel1 7 } sensor1-8 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for internal switch sensor 8 (0 = OPEN, 1 = CLOSED)." ::= { channel1 8 } switch-label-1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The label for switch sensor 1" ::= { channel1 9 } switch-label-2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The label for switch sensor 2" ::= { channel1 10 } switch-label-3 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The label for switch sensor 3" ::= { channel1 11 } switch-label-4 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The label for switch sensor 4" ::= { channel1 12 } switch-label-5 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The label for switch sensor 5" ::= { channel1 13 } switch-label-6 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The label for switch sensor 6" ::= { channel1 14 } switch-label-7 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The label for switch sensor 7" ::= { channel1 15 } switch-label-8 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The label for switch sensor 8" ::= { channel1 16 } sensor2-1 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 2-1. If a temp or temp/humidity sensor is connected, value will be current temperature in Celsius." ::= { channel2 1 } sensor2-2 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 2-2. If a temp or temp/humidity sensor is connected, value will be current temperature in Fahrenheit." ::= { channel2 2 } sensor2-3 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 2-3. If temp/humidity sensor is connected, value will be current %RH." ::= { channel2 3 } sensor2-4 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 2-4. If temp/humidity sensor is connected, value will be current Heat Index in Fahrenheit." ::= { channel2 4 } sensor2-5 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 2-5. If temp/humidity sensor is connected, value will be current Heat Index in Celsius." ::= { channel2 5 } sensor2-6-label OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The label of this sensor" ::= { channel2 6} sensor3-1 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 3-1. If a temp or temp/humidity sensor is connected, value will be current temperature in Celsius." ::= { channel3 1 } sensor3-2 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 3-2. If a temp or temp/humidity sensor is connected, value will be current temperature in Fahrenheit." ::= { channel3 2 } sensor3-3 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 3-3. If temp/humidity sensor is connected, value will be current %RH." ::= { channel3 3 } sensor3-4 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 3-4. If temp/humidity sensor is connected, value will be current Heat Index in Fahrenheit." ::= { channel3 4 } sensor3-5 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 3-5. If temp/humidity sensor is connected, value will be current Heat Index in Celsius." ::= { channel3 5 } sensor3-6-label OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The label of this sensor" ::= { channel3 6} sensor4-1 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 4-1. If a temp or temp/humidity sensor is connected, value will be current temperature in Celsius." ::= { channel4 1 } sensor4-2 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 4-2. If a temp or temp/humidity sensor is connected, value will be current temperature in Fahrenheit." ::= { channel4 2 } sensor4-3 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 4-3. If temp/humidity sensor is connected, value will be current %RH." ::= { channel4 3 } sensor4-4 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 4-4. If temp/humidity sensor is connected, value will be current Heat Index in Fahrenheit." ::= { channel4 4 } sensor4-5 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 4-5. If temp/humidity sensor is connected, value will be current Heat Index in Celsius." ::= { channel4 5 } sensor4-6-label OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The label of this sensor" ::= { channel4 6} alarm1 OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm for sensor channel 1. The binary equivalent of the decimal number displayed will indicate which switch sensors are currently in an alarm state (0 = sensor ok, 1 = sensor in alarm state). For example, if switch sensors 1 and 4 are in alarm state, the value displayed will be 9, which equals 00001001 in binary." ::= { traps 1 } alarm2 OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm for sensor channel 2. If a digital temperature/humidity or digital temperature sensor is connected to this channel, 0 = sensor ok, 1 = high temp alarm, 2 = low temp alarm, 3 = humidity alarm. If a Switch Sensor Expansion box is connected, the binary equivalent of the decimal number displayed will indicate which switch sensors are currently in an alarm state (0 = sensor ok, 1 = sensor in alarm state). For example, if switch sensors 1 and 4 are in alarm state, the value displayed will be 9, which equals 00001001 in binary." ::= { traps 2 } alarm3 OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm for sensor channel 3. If a digital temperature/humidity or digital temperature sensor is connected to this channel, 0 = sensor ok, 1 = high temp alarm, 2 = low temp alarm, 3 = humidity alarm. If a Switch Sensor Expansion box is connected, the binary equivalent of the decimal number displayed will indicate which switch sensors are currently in an alarm state (0 = sensor ok, 1 = sensor in alarm state). For example, if switch sensors 1 and 4 are in alarm state, the value displayed will be 9, which equals 00001001 in binary." ::= { traps 3 } alarm4 OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm for sensor channel 4. If a digital temperature/humidity or digital temperature sensor is connected to this channel, 0 = sensor ok, 1 = high temp alarm, 2 = low temp alarm, 3 = humidity alarm. If a Switch Sensor Expansion box is connected, the binary equivalent of the decimal number displayed will indicate which switch sensors are currently in an alarm state (0 = sensor ok, 1 = sensor in alarm state). For example, if switch sensors 1 and 4 are in alarm state, the value displayed will be 9, which equals 00001001 in binary." ::= { traps 4 } alarmMessage1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Alarm Message from sensor channel 1 (Internal)" ::= { traps 5 } alarmMessage2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Alarm Message from sensor channel 2 (External)" ::= { traps 6 } alarmMessage3 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Alarm Message from sensor channel 3 (External)" ::= { traps 7 } alarmMessage4 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Alarm Message from sensor channel 4 (External)" ::= { traps 8 } threshold1-1 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 1 defined for Channel 1" ::= { channels1 1 } threshold1-2 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 2 defined for Channel 1" ::= { channels1 2 } threshold1-3 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 3 defined for Channel 1" ::= { channels1 3 } threshold1-4 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 4 defined for Channel 1" ::= { channels1 4 } threshold1-5 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 5 defined for Channel 1" ::= { channels1 5 } threshold1-6 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 6 defined for Channel 1" ::= { channels1 6 } threshold1-7 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 7 defined for Channel 1" ::= { channels1 7 } threshold1-8 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 8 defined for Channel 1" ::= { channels1 8 } threshold2-1 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 1 defined for Channel 2" ::= { channels2 1 } threshold2-2 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 2 defined for Channel 2" ::= { channels2 2 } threshold2-3 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 3 defined for Channel 2" ::= { channels2 3 } threshold2-4 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 4 defined for Channel 2" ::= { channels2 4 } threshold3-1 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 1 defined for Channel 3" ::= { channels3 1 } threshold3-2 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 2 defined for Channel 3" ::= { channels3 2 } threshold3-3 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 3 defined for Channel 3" ::= { channels3 3 } threshold3-4 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 4 defined for Channel 3" ::= { channels3 4 } threshold4-1 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 1 defined for Channel 4" ::= { channels4 1 } threshold4-2 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 2 defined for Channel 4" ::= { channels4 2 } threshold4-3 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 3 defined for Channel 4" ::= { channels4 3 } threshold4-4 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold 4 defined for Channel 4" ::= { channels4 4 } -- ROOMALERT11E TRAPS tempAlarm1-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage2, sensor2-1, sensor2-2, sensor2-1 } DESCRIPTION "A tempAlarm1 trap signifies that the current temperature on external sensor 1 is outside the defined high or low threshold." ::= 1 room-alert-11E-SNMP-trap TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage1,alarmMessage2,alarmMessage3,alarmMessage4 } DESCRIPTION "A Room Alert 11E SNMP Trap indicates that an alarm condition has occurred on the sensor inidcated by the alarmMessage variable." ::= 2 tempAlarm2-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage3, sensor3-1, sensor3-2, sensor3-1 } DESCRIPTION "A tempAlarm2 trap signifies that the current temperature on external sensor 2 is outside the defined high or low threshold." ::= 3 tempClear2-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage3, sensor3-1, sensor3-2, sensor3-1 } DESCRIPTION "A tempClear2 trap signifies that the current temperature on external sensor 2 has returned to a normal condition and is within the defined high or low threshold." ::= 4 tempAlarm3-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage4, sensor4-1, sensor4-2, sensor4-1 } DESCRIPTION "A tempAlarm3 trap signifies that the current temperature on external sensor 3 is outside the defined high or low threshold." ::= 5 tempClear3-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage4, sensor4-1, sensor4-2, sensor4-1 } DESCRIPTION "A tempClear3 trap signifies that the current temperature on external sensor 3 has returned to a normal condition and is within the defined high or low threshold." ::= 6 humidityAlarm1-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage2, sensor2-1, sensor2-2, sensor2-3 } DESCRIPTION "A humidityAlarm1 trap signifies that the current humidity on external sensor 1 is outside the defined high or low threshold." ::= 7 humidityClear1-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage2, sensor2-1, sensor2-2, sensor2-3 } DESCRIPTION "A humidityClear1 trap signifies that the current humidity on external sensor 1 has returned to a normal condition and is within the defined high or low threshold." ::= 8 humidityAlarm2-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage3, sensor3-1, sensor3-2, sensor3-3 } DESCRIPTION "A humidityAlarm2 trap signifies that the current humidity on external sensor 2 is outside the defined high or low threshold." ::= 9 humidityClear2-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage3, sensor3-1, sensor3-2, sensor3-3 } DESCRIPTION "A humidityClear2 trap signifies that the current humidity on external sensor 2 has returned to a normal condition and is within the defined high or low threshold." ::= 10 humidityAlarm3-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage4, sensor4-1, sensor4-2, sensor4-3 } DESCRIPTION "A humidityAlarm3 trap signifies that the current humidity on external sensor 3 is outside the defined high or low threshold." ::= 11 humidityClear3-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage4, sensor4-1, sensor4-2, sensor4-3 } DESCRIPTION "A humidityClear3 trap signifies that the current humidity on external sensor 3 has returned to a normal condition and is within the defined high or low threshold." ::= 12 switchAlarm1-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage1, sensor1-1, sensor1-1, sensor1-1 } DESCRIPTION "A switchAlarm1 trap signifies that switch sensor 1 is in an alarm state." ::= 13 switchClear1-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage1, sensor1-1, sensor1-1, sensor1-1 } DESCRIPTION "A switchClear1 trap signifies that the switch sensor 1 has returned to a normal state." ::= 14 switchAlarm2-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage1, sensor1-2, sensor1-2, sensor1-2 } DESCRIPTION "A switchAlarm2 trap signifies that switch sensor 2 is in an alarm state." ::= 15 switchClear2-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage1, sensor1-2, sensor1-2, sensor1-2 } DESCRIPTION "A switchClear2 trap signifies that the switch sensor 2 has returned to a normal state." ::= 16 switchAlarm3-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage1, sensor1-3, sensor1-3, sensor1-3 } DESCRIPTION "A switchAlarm1 trap signifies that switch sensor 1 is in an alarm state." ::= 17 switchClear3-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage1, sensor1-3, sensor1-3, sensor1-3 } DESCRIPTION "A switchClear3 trap signifies that the switch sensor 3 has returned to a normal state." ::= 18 switchAlarm4-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage1, sensor1-4, sensor1-4, sensor1-4 } DESCRIPTION "A switchAlarm4 trap signifies that switch sensor 4 is in an alarm state." ::= 19 switchClear4-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage1, sensor1-4, sensor1-4, sensor1-4 } DESCRIPTION "A switchClear4 trap signifies that the switch sensor 4 has returned to a normal state." ::= 20 switchAlarm5-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage1, sensor1-5, sensor1-5, sensor1-5 } DESCRIPTION "A switchAlarm5 trap signifies that switch sensor 5 is in an alarm state." ::= 21 switchClear5-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage1, sensor1-5, sensor1-5, sensor1-5 } DESCRIPTION "A switchClear5 trap signifies that the switch sensor 5 has returned to a normal state." ::= 22 switchAlarm6-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage1, sensor1-6, sensor1-6, sensor1-6 } DESCRIPTION "A switchAlarm6 trap signifies that switch sensor 6 is in an alarm state." ::= 23 switchClear6-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage1, sensor1-6, sensor1-6, sensor1-6 } DESCRIPTION "A switchClear6 trap signifies that the switch sensor 6 has returned to a normal state." ::= 24 switchAlarm7-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage1, sensor1-7, sensor1-7, sensor1-7 } DESCRIPTION "A switchAlarm7 trap signifies that switch sensor 7 is in an alarm state." ::= 25 switchClear7-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage1, sensor1-7, sensor1-7, sensor1-7 } DESCRIPTION "A switchClear7 trap signifies that the switch sensor 7 has returned to a normal state." ::= 26 switchAlarm8-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage1, sensor1-8, sensor1-8, sensor1-8 } DESCRIPTION "A switchAlarm8 trap signifies that switch sensor 8 is in an alarm state." ::= 27 switchClear8-11e TRAP-TYPE ENTERPRISE roomalert11E VARIABLES { alarmMessage1, sensor1-8, sensor1-8, sensor1-8 } DESCRIPTION "A switchClear8 trap signifies that the switch sensor 8 has returned to a normal state." ::= 28 END