-- --defines ROOMALERTST4E-MIB for SNMP agent extension of Room Alert ST4E --Contents: Global Registration Module -- Room Alert OIDs - Enterprise 20916 --Version: 1.0.0 --Date: 29 January 2008 --Developed By: AVTECH Software, Inc. -- --Copyright (c) 2008 AVTECH Software, Inc. -- ROOMALERTST4E-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, IpAddress, Counter, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; avtech OBJECT IDENTIFIER ::= { enterprises 20916 } products OBJECT IDENTIFIER ::= { avtech 1 } ROOMALERTST4E OBJECT IDENTIFIER ::= { products 6 } sensors OBJECT IDENTIFIER ::= { ROOMALERTST4E 1 } signaltower OBJECT IDENTIFIER ::= { ROOMALERTST4E 2 } traps OBJECT IDENTIFIER ::= { ROOMALERTST4E 3 } internal OBJECT IDENTIFIER ::= { sensors 1 } temperature OBJECT IDENTIFIER ::= { internal 1 } humidity OBJECT IDENTIFIER ::= { internal 2 } heat-index OBJECT IDENTIFIER ::= { internal 3 } digital OBJECT IDENTIFIER ::= { sensors 2 } digital-sen1 OBJECT IDENTIFIER ::= { digital 1 } digital-sen2 OBJECT IDENTIFIER ::= { digital 2 } switch OBJECT IDENTIFIER ::= { sensors 3 } -- Room Alert ST4E MIB -- Parameters internal-tempf OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The internal temperature reading in Fahrenheit. Because the SNMP Protocol does not support floating point numbers, values are scaled by 100 and should be divided by 100 to get the actual value." ::= { temperature 1 } internal-tempc OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The internal temperature reading in Celsius. Because the SNMP Protocol does not support floating point numbers, values are scaled by 100 and should be divided by 100 to get the actual value." ::= { temperature 2 } internal-humidity OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The internal relative humidity reading in %RH. Because the SNMP Protocol does not support floating point numbers, values are scaled by 100 and should be divided by 100 to get the actual value." ::= { humidity 1 } internal-heat-index OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The internal heat index reading in Fahrenheit. Because the SNMP Protocol does not support floating point numbers, values are scaled by 100 and should be divided by 100 to get the actual value." ::= { heat-index 1 } digital-sen1-1 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Celsius. If this sensor is a Digital Power Sensor, this value represents the Current reading in Amperage." ::= { digital-sen1 1 } digital-sen1-2 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Power reading in Watts." ::= { digital-sen1 2 } digital-sen1-3 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Digital Power Sensor, this value represents the Voltage reading in Volts." ::= { digital-sen1 3 } digital-sen1-4 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Reference reading in Volts." ::= { digital-sen1 4 } digital-sen2-1 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Celsius. If this sensor is a Digital Power Sensor, this value represents the Current reading in Amperage." ::= { digital-sen2 1 } digital-sen2-2 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Power reading in Watts." ::= { digital-sen2 2 } digital-sen2-3 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Digital Power Sensor, this value represents the Voltage reading in Volts." ::= { digital-sen2 3 } digital-sen2-4 OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Reference reading in Volts." ::= { digital-sen2 4 } switch-sen1 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for switch sensor 1 (0 = OPEN, 1 = CLOSED)." ::= { switch 1 } red-led OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS current DESCRIPTION "The status of this Signal Tower element (0 = OFF, 1 = ON)." ::= { signaltower 1 } amber-led OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS current DESCRIPTION "The status of this Signal Tower element (0 = OFF, 1 = ON)." ::= { signaltower 2 } green-led OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS current DESCRIPTION "The status of this Signal Tower element (0 = OFF, 1 = ON)." ::= { signaltower 3 } blue-led OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS current DESCRIPTION "The status of this Signal Tower element (0 = OFF, 1 = ON)." ::= { signaltower 4 } white-led OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS current DESCRIPTION "The status of this Signal Tower element (0 = OFF, 1 = ON)." ::= { signaltower 5 } alarm1 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS current DESCRIPTION "The status of this Signal Tower element (0 = OFF, 1 = ON)." ::= { signaltower 6 } alarm2 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS current DESCRIPTION "The status of this Signal Tower element (0 = OFF, 1 = ON)." ::= { signaltower 7 } alarmmessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Last Alarm Message" ::= { traps 1 } -- ROOMALERTST4E TRAPS room-alert-st4e-snmp-trap TRAP-TYPE ENTERPRISE ROOMALERTST4E VARIABLES { alarmmessage } DESCRIPTION "A room-alert-st4e-snmp-trap indicates that an alarm condition has occurred on the sensor indicated by the alarmmessage variable." ::= 2 END