-- ***************************************************************** -- NMS-OPTICAL-PORT-MIB: NMS OPTICAL-POWER MIB file -- AUG 2010 -- ***************************************************************** -- NMS-OPTICAL-PORT-MIB DEFINITIONS ::= BEGIN IMPORTS NOTIFICATION-TYPE,INTEGER FROM SNMPv2-SMI Counter, IpAddress, Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString, ifIndex, PhysAddress FROM RFC1213-MIB nmsMgmt FROM NMS-SMI nmsEPONGroup FROM NMS-SMI; --definition of NMS device optical port receive/send related power parameters opticalPortPower OBJECT IDENTIFIER ::= { nmsMgmt 183 } opticalPortPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF OpticalPortPowerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of optical interface entries." ::= { opticalPortPower 1 } opticalPortPowerEntry OBJECT-TYPE SYNTAX OpticalPortPowerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An optical interface entry containing objects at the subnetwork layer and below for a particular interface." INDEX { opIfIndex } ::= { opticalPortPowerTable 1 } OpticalPortPowerEntry ::= SEQUENCE { opIfIndex INTEGER, opIfDescr DisplayString, opIfAdminStatus INTEGER, opIfOperStatus INTEGER, opIfRxPowerCurr INTEGER, opIfRxPowerULimit INTEGER, opIfRxPowerLLimit INTEGER, opIfTxPowerCurr INTEGER, opIfTxPowerULimit INTEGER, opIfTxPowerLLimit INTEGER, opIfUploadBERLimit INTEGER, opIfPowerTrapStatus INTEGER, opIfTemperature INTEGER, opIfVolt INTEGER, opIfCurrent INTEGER } opIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each optical interface. The same value as ifIndex of ifTable in RFC1213." ::= { opticalPortPowerEntry 1 } opIfDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A textual string containing information about the optical interface. The same value as ifDesc of ifTable in RFC1213. " ::= { opticalPortPowerEntry 2 } opIfAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), -- ready to pass packets down(2), testing(3) -- in some test mode } ACCESS read-only STATUS mandatory DESCRIPTION "The desired state of the interface. The same value as ifAdminStatus of ifTable in RFC1213." ::= { opticalPortPowerEntry 3 } opIfOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), -- ready to pass packets down(2), testing(3) -- in some test mode } ACCESS read-only STATUS mandatory DESCRIPTION "The current operational state of the optical interface. The same value as ifOperStatus of ifTable in RFC1213." ::= { opticalPortPowerEntry 4 } opIfRxPowerCurr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each optical interface, that means optical current receive power value." ::= { opticalPortPowerEntry 5 } opIfRxPowerULimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A unique value for each optical interface, that means optical receive upper limit." ::= { opticalPortPowerEntry 6 } opIfRxPowerLLimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A unique value for each optical interface, that means optical receiving lower limit." ::= { opticalPortPowerEntry 7 } opIfTxPowerCurr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each optical interface, that means optical current sending power value." ::= { opticalPortPowerEntry 8 } opIfTxPowerULimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A unique value for each optical interface, that means optical sending upper limit." ::= { opticalPortPowerEntry 9 } opIfTxPowerLLimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A unique value for each optical interface, that means optical sending lower limit." ::= { opticalPortPowerEntry 10 } opIfUploadBERLimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A unique value for each optical interface, that means optical port BER threshold." ::= { opticalPortPowerEntry 11 } opIfPowerTrapStatus OBJECT-TYPE SYNTAX INTEGER{ on(0), off(1) } ACCESS read-write STATUS mandatory DESCRIPTION "A unique value for each optical interface, that means optical R/X power limit trap sending status. 0-on, 1-off." ::= { opticalPortPowerEntry 12 } opIfTemperature OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each optical interface, that means optical module temperature. Unit is 1/256 Celsius." ::= { opticalPortPowerEntry 13 } opIfVolt OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each optical interface, that means optical module volt. Unit is 100uV." ::= { opticalPortPowerEntry 14 } opIfCurrent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each optical interface, that means optical module current. Unit is 2uA." ::= { opticalPortPowerEntry 15 } opIfTransMode OBJECT-TYPE SYNTAX INTEGER{ upload(1), download(2) } ACCESS not-accessible STATUS mandatory DESCRIPTION "A value for optical interface trasporting mode, 1-upload, 2-download." ::= { opticalPortPower 2 } opIfTransPowerAlarm OBJECT-TYPE SYNTAX INTEGER{ over(1), below(2), normal(3) } ACCESS not-accessible STATUS mandatory DESCRIPTION "A value for optical interface trasporting power alarm, 1-over than upper limit, 2-lower than lower limit." ::= { opticalPortPower 3 } opIfBERStatus OBJECT-TYPE SYNTAX INTEGER{ exception(1), normal(2) } ACCESS not-accessible STATUS mandatory DESCRIPTION "A value for optical interface BER status, 1-exception, 2-recover to normal status." ::= { opticalPortPower 4 } -- Notifications nmsOpIfPowerThresNotifications OBJECT IDENTIFIER ::= { opticalPortPower 5 } nmsOpIfPowerThresNotification NOTIFICATION-TYPE OBJECTS { opIfIndex, opIfDescr, opIfTransMode, opIfTransPowerAlarm } STATUS current DESCRIPTION "The agent generates this notification when optical interface upload/download power exceed the threshold ruled in opticalPortPowerTable." ::= { nmsOpIfPowerThresNotifications 1 } -- Notifications opIfUploadBERNotifications OBJECT IDENTIFIER ::= { opticalPortPower 6 } opIfUploadBERNotification NOTIFICATION-TYPE OBJECTS { opIfIndex, opIfDescr, opIfBERStatus } STATUS current DESCRIPTION "The agent generates this notification when optical interface upload BER exceed the threshold ruled in opticalPortPowerTable." ::= { opIfUploadBERNotifications 1 } END