BENU-CHASSIS-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32,Unsigned32,TimeTicks FROM SNMPv2-SMI ifIndex,ifDescr,ifType,ifAdminStatus,ifOperStatus FROM IF-MIB benuPlatform FROM BENU-PLATFORM-MIB DisplayString FROM SNMPv2-TC; benuChassisMIB MODULE-IDENTITY LAST-UPDATED "201611180000Z" -- 18 November 2016 ORGANIZATION "Benu Networks" CONTACT-INFO "Benu Networks Inc, 300 Concord Road, Billerca MA 01821 Email: support@benunets.com" DESCRIPTION "Initial creation MIB module for Benu Networks Chassis. Copyright (C) 2001, 2008 by Benu Networks, Inc. All rights reserved." REVISION "201611180000Z" -- 18 November 2016 DESCRIPTION "Added xMEG card type" REVISION "201610140000Z" -- 14 October 2016 DESCRIPTION "Changes for xMEG platform" REVISION "201601260000Z" -- 26 January 2016 DESCRIPTION "Added benuCardIfVirtualType" REVISION "201510140000Z" -- 14 October 2015 DESCRIPTION "Added benuPowerSupplyTable" REVISION "201501270000Z" -- 27 January 2015 DESCRIPTION "Updated benuChassisId from read-write to read-only. Also, updated the description appropriately." REVISION "201501050000Z" -- 05 January 2015 DESCRIPTION "Updated notification assignments to comply with standards (RFC 2578)." REVISION "201411140000Z" -- 14 November 2014 DESCRIPTION "changed benuChassisNotifObjects type to scalar (2 to 0)" REVISION "201406270000Z" DESCRIPTION "Added new encapsulation column in Card interface table" REVISION "201311250000Z" DESCRIPTION "Added Fan Table " REVISION "201212120000Z" -- 12 December 2012 DESCRIPTION "Initial creation MIB module for Benu Networks Chassis" ::= { benuPlatform 1 } benuChassisMIBObjects OBJECT IDENTIFIER ::= { benuChassisMIB 1 } benuChassisNotifObjects OBJECT IDENTIFIER ::= { benuChassisMIB 0 } benuChassisNotifVariables OBJECT IDENTIFIER ::= { benuChassisMIB 2 } -- MIB contains five groups benuChassisInfo OBJECT IDENTIFIER ::= { benuChassisMIBObjects 1 } benuCardInfo OBJECT IDENTIFIER ::= { benuChassisMIBObjects 2 } benuCardIfInfo OBJECT IDENTIFIER ::= { benuChassisMIBObjects 3 } benuSensorInfo OBJECT IDENTIFIER ::= { benuChassisMIBObjects 4 } benuChassisGeneralInfo OBJECT IDENTIFIER ::= { benuChassisMIBObjects 5 } benuFanInfo OBJECT IDENTIFIER ::= { benuChassisMIBObjects 6 } benuPowerSupplyInfo OBJECT IDENTIFIER ::= { benuChassisMIBObjects 7 } -- -- chassis group information. -- benuChassisType OBJECT-TYPE SYNTAX INTEGER { meg100(1), meg400(2), meg1200(3), meg50(4), xMEG100(5), xMEG10(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Chassis type." ::= { benuChassisInfo 1 } benuChassisHwVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Chassis hardware revision level, or an empty string if unavailable." ::= { benuChassisInfo 2 } benuChassisId OBJECT-TYPE -- Serial Number SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Unique ID string. Defaults to chassis serial number if available, otherwise empty" ::= { benuChassisInfo 3 } benuChassisNumOfSlots OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of slots in this chassis, or -1 if neither applicable nor determinable." ::= { benuChassisInfo 4 } benuChassisPowerTrapEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object controls SNMP traps for chassis Power Failure. If its value is set to enabled(1), then traps are generated. If the value is disabled(2), then traps are not generated. By default, this object has the value enabled(1). " DEFVAL { enabled } ::= { benuChassisInfo 5 } benuChassisFanTrapEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object controls SNMP traps for chassis Fan Failure. If its value is set to enabled(1), then traps are generated. If the value is disabled(2), then traps are not generated. By default, this object has the value enabled(1). " DEFVAL { enabled } ::= { benuChassisInfo 6 } benuChassisSensorTrapEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object controls SNMP traps for chassis senor Failure. If its value is set to enabled(1), then traps are generated. If the value is disabled(2), then traps are not generated. By default, this object has the value enabled(1). " DEFVAL { enabled } ::= { benuChassisInfo 7 } benuSysUpTimeAtLastChassisChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Time (in hundredths of a second) from the last cold start to the last change in the chassis' configuration. This value will be updated whenever the chassis experiences a change in the count, type, or slot position of a card in cardTable." ::= { benuChassisInfo 8 } -- -- The Benu Card Table -- benuCardTable OBJECT-TYPE SYNTAX SEQUENCE OF BenuCardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Chassis card table." ::= { benuCardInfo 1 } benuCardEntry OBJECT-TYPE SYNTAX BenuCardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Chassis card table." INDEX { benuCardIndex } ::= { benuCardTable 1 } BenuCardEntry ::= SEQUENCE { benuCardIndex Unsigned32, benuCardType INTEGER, benuCardDescr DisplayString, benuCardSerial DisplayString, benuCardPartNumber DisplayString, benuCardHwVersion DisplayString, benuCardSwVersion DisplayString, benuCardSlotNumber Integer32, benuCardRamSize Integer32, benuCardPrimaryDiskSize Integer32, benuCardSecondaryDiskSize Integer32, benuCardOperStatus INTEGER } benuCardIndex OBJECT-TYPE SYNTAX Unsigned32(1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index into cardTable (not physical chassis slot number)." ::= { benuCardEntry 1 } benuCardType OBJECT-TYPE SYNTAX INTEGER { unknown(0), rsm(1), switchFabric(2), shelfmgr(3), seFP(4), inputOutputCard(5), switchMesh(6), xmeg(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Functional type of this card." ::= { benuCardEntry 2 } benuCardDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Text description of this card." ::= { benuCardEntry 3 } benuCardSerial OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number of this card, or zero if unavailable." ::= { benuCardEntry 4 } benuCardPartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The part number of this card, or an empty string if unavailable." ::= { benuCardEntry 5 } benuCardHwVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware revision level of this card, or an empty string if unavailable." ::= { benuCardEntry 6 } benuCardSwVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Version of the firmware or microcode installed on this card, or an empty string if unavailable." ::= { benuCardEntry 7 } benuCardSlotNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number relative to the containing card or chassis, or -1 if neither applicable nor determinable." ::= { benuCardEntry 8 } benuCardRamSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of kilobytes of DRAM. A value -1 means not available / not applicable A value 0 means internal error." ::= { benuCardEntry 9 } benuCardPrimaryDiskSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of kilobytes of Disk Memory (SATA or Hard Disk). A value -1 means not available / not applicable. A value 0 means internal error." ::= { benuCardEntry 10 } benuCardSecondaryDiskSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of kilobytes of Disk Memory (SATA or Hard Disk). A value -1 means not available / not applicable. A value 0 means internal error." ::= { benuCardEntry 11 } benuCardOperStatus OBJECT-TYPE SYNTAX INTEGER { notSpecified(1), up(2), down(3), standby(4), rom(5), flash(6), diag(7), boot(8), config(9) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operational status of the card. cardOperStatus is up when a card is recognized by the device and is enabled for operation. cardOperStatus is down if the card is not recognized by the device, or if it is not enabled for operation. cardOperStatus is standby if the card is enabled and acting as a standby slave. Intermediate stages (rom,flash,diag,boot,config) are also exposed." ::= { benuCardEntry 12 } -- -- The card Interface table -- benuCardIfIndexTable OBJECT-TYPE SYNTAX SEQUENCE OF BenuCardIfIndexEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Chassis card Interface table." ::= { benuCardIfInfo 1 } benuCardIfIndexEntry OBJECT-TYPE SYNTAX BenuCardIfIndexEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Chassis card table." INDEX { benuCardIfIndex } ::= { benuCardIfIndexTable 1 } BenuCardIfIndexEntry ::= SEQUENCE { benuCardIfIndex Unsigned32, benuCardIfName DisplayString, benuCardIfPortNumber Integer32, benuCardIfSlotNumber Integer32, benuCardIfLinkUpDownEnable INTEGER, benuCardIfPortType INTEGER, benuCardIfBindName DisplayString, benuCardIfEncapsulation DisplayString, benuCardIfVirtualType INTEGER } benuCardIfIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "matches RFC1213 ifTable IfIndex" ::= { benuCardIfIndexEntry 1 } benuCardIfName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "matches RFC1213 ifXTable IfName" ::= { benuCardIfIndexEntry 2 } benuCardIfPortNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Chassis port number, unique per port on a given card if available." ::= { benuCardIfIndexEntry 3 } benuCardIfSlotNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Physical slot number of the card in the Chassis which contains this interface" ::= { benuCardIfIndexEntry 4 } benuCardIfLinkUpDownEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This enables and disables the sending of the proprietary notifications 'benuLinkUpTrap' and 'benuLinkDownTrap' that provide more information than the standard link up and link down notifications. By default, these traps are disabled." DEFVAL { disabled } ::= { benuCardIfIndexEntry 5 } benuCardIfPortType OBJECT-TYPE SYNTAX INTEGER { none(0), ethernet(1), fastEthernet(2), gigaEthernet(3), tunnel(4), ipGre(5), vlan(6), l2tp(7), cable(8), bridge(9), ip(10), multiBind(11), p2p(12), loopback(13), multiBindLastResort(14), lag(15), max(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to identify port types for a given card." ::= { benuCardIfIndexEntry 6 } benuCardIfBindName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "interface name which is bound to this port . This string will be empty if there is no interface bind to this port " ::= { benuCardIfIndexEntry 7 } benuCardIfEncapsulation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The encapsulation method used by the port." ::= { benuCardIfIndexEntry 8 } benuCardIfVirtualType OBJECT-TYPE SYNTAX INTEGER { physical(1), virtual(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to identify virtualized interfaces." ::= { benuCardIfIndexEntry 9 } -- The Sensor Table benuSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF BenuSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Chassis card table." ::= { benuSensorInfo 1 } benuSensorEntry OBJECT-TYPE SYNTAX BenuSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Chassis card table." INDEX { benuSensorCardIndex , benuSensorIndex } ::= { benuSensorTable 1 } BenuSensorEntry ::= SEQUENCE { benuSensorCardIndex Unsigned32, benuSensorIndex Unsigned32, benuSensorName DisplayString, benuSensorType INTEGER, benuSensorValue Integer32, benuSensorMinThresh Integer32, benuSensorMaxThresh Integer32, benuSensorState INTEGER, benuSensorId Integer32 } benuSensorCardIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "cardIndex of the card in the Chassis cardTable which contains this sensor." ::= { benuSensorEntry 1 } benuSensorIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index into sensorTable." ::= { benuSensorEntry 2 } benuSensorName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the sensor." ::= { benuSensorEntry 3 } benuSensorType OBJECT-TYPE SYNTAX INTEGER { other(0), temparature(1), voltage(2), electicCurrent(3), fan(4), power(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of the sensor." ::= { benuSensorEntry 4 } benuSensorValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Current Value of this sensor. The unit types for different type of sensors: temparature -- celcius Fan -- rpm Volatage -- volts Electric Current -- amperes Power -- watts " ::= { benuSensorEntry 5 } benuSensorMinThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum threshold for this sensor." ::= { benuSensorEntry 6 } benuSensorMaxThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum threshold for this sensor." ::= { benuSensorEntry 7 } benuSensorState OBJECT-TYPE SYNTAX INTEGER { other(0), normal(1), critical(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "State of the sensor." ::= { benuSensorEntry 8 } benuSensorId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique ID of the sensor." ::= { benuSensorEntry 9 } -- The Fan Table benuFanTable OBJECT-TYPE SYNTAX SEQUENCE OF BenuFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Chassis Fan table." ::= { benuFanInfo 1 } benuFanEntry OBJECT-TYPE SYNTAX BenuFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Chassis card table." INDEX { benuFanCardIndex } ::= { benuFanTable 1 } BenuFanEntry ::= SEQUENCE { benuFanCardIndex Unsigned32, benuFanMaxSpeed Unsigned32, benuFanCurSpeed Unsigned32, benuFanStatus Integer32 } benuFanCardIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "cardIndex of the card in the Chassis cardTable which contains this Fan." ::= { benuFanEntry 1 } benuFanMaxSpeed OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum expected speed of each Fan. This value is applicable to all Fans in the card. Units : The value range is from 0 to 100" ::= { benuFanEntry 2 } benuFanCurSpeed OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Current speed of each Fan. This value is applicable to all Fans in the card. Units : The value range is from 0 to 100 and is less than or equal to benuFanMaxSpeed" ::= { benuFanEntry 3 } benuFanStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " A value of -1 means Not available / Not applicable. The lower order 7 bits indicates status of 7 Fans. A bit value of one indicates FAN is non-operational. A bit value of zero indicates FAN is operational. Examples : (a) Value of 1 ( 0000 0001 ) indicates FAN #1 is non-operational. (b) Value of 9 ( 0000 1001 ) indicates FAN #1 and FAN #4 are non-operational. (c) Value of 73( 0100 1001 ) indicates FAN #1,FAN #4 and FAN #7 are non-operational. " ::= { benuFanEntry 4 } -- The PowerSupply Table benuPowerSupplyTable OBJECT-TYPE SYNTAX SEQUENCE OF BenuPowerSupplyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Benu power supply state information." ::= { benuPowerSupplyInfo 1 } benuPowerSupplyEntry OBJECT-TYPE SYNTAX BenuPowerSupplyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Power supply table." INDEX { benuPowerSupplyIndex } ::= { benuPowerSupplyTable 1 } BenuPowerSupplyEntry ::= SEQUENCE { benuPowerSupplyIndex INTEGER, benuPowerSupplyName DisplayString, benuPowerSupplyPresent INTEGER, benuPowerSupplyType INTEGER, benuPowerSupplyPowered INTEGER } benuPowerSupplyIndex OBJECT-TYPE SYNTAX INTEGER { powerA(1), powerB(2) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is used to identify the power supply." ::= { benuPowerSupplyEntry 1 } benuPowerSupplyName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power supply." ::= { benuPowerSupplyEntry 2 } benuPowerSupplyPresent OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether or not the power supply is installed in the chassis." ::= { benuPowerSupplyEntry 3 } benuPowerSupplyType OBJECT-TYPE SYNTAX INTEGER { ac(1), dc(2), notApplicable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the type of the power supply." ::= { benuPowerSupplyEntry 4 } benuPowerSupplyPowered OBJECT-TYPE SYNTAX INTEGER { powered(1), notPowered(2), notApplicable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether or not the power supply is actively supplying power. The value of notApplicable(3) will show if the entry for benuPowerSupplyPresent is no(2)." ::= { benuPowerSupplyEntry 5 } -- Chassis MIB General Info benuSysUpTimeSinceLastConfigChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The time (in hundredths of a second) since the last configuration change in the system." ::= { benuChassisGeneralInfo 1 } -- Chassis MIB traps Definitions benuChassisPowerFailureInfo OBJECT-TYPE SYNTAX INTEGER { powerFailureA(1), powerFailureB(2), powerRestoredA(3), powerRestoredB(4) } MAX-ACCESS accessible-for-notify STATUS obsolete DESCRIPTION "Indicates the location of the Power Failure." ::= { benuChassisNotifVariables 1 } benuChassisPowerFailure NOTIFICATION-TYPE OBJECTS { benuChassisPowerFailureCardInfo, benuChassisPowerFailureInfo } STATUS obsolete DESCRIPTION "A chassisPowerFailureTrap is generated when a Power Failure is detected in the system" ::= { benuChassisNotifObjects 1 } benuChassisFanFailureInfo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the location of the Fan Failure." ::= { benuChassisNotifVariables 2 } benuChassisFanFailureTrap NOTIFICATION-TYPE OBJECTS { benuChassisFanFailureInfo } STATUS current DESCRIPTION "A chassisFanFailureTrap is generated when a Fan Failure is detected in the system" ::= { benuChassisNotifObjects 2 } benuLinkUpTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr, ifType, ifAdminStatus, ifOperStatus } STATUS current DESCRIPTION "A proprietary Link Up Notification for all interfaces. This notification contains more details than the standard 'linkUp' notification in RFC 2863." ::= { benuChassisNotifObjects 3 } benuLinkDownTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr, ifType, ifAdminStatus, ifOperStatus } STATUS current DESCRIPTION "A proprietary Link Down Notification for all interfaces. This notification contains more details than the standard 'linkDown' notification in RFC 2863." ::= { benuChassisNotifObjects 4 } benuChassisPowerFailureCardInfo OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS obsolete DESCRIPTION "Indicates the Card Index Card Index starts from #1. " ::= { benuChassisNotifVariables 3 } benuSensorCritical NOTIFICATION-TYPE OBJECTS { benuSensorName, benuSensorType, benuSensorValue, benuSensorId } STATUS current DESCRIPTION "This notification signifies the transition of the sensor state from normal to critical." ::= { benuChassisNotifObjects 5 } benuSensorNormal NOTIFICATION-TYPE OBJECTS { benuSensorName, benuSensorType, benuSensorValue, benuSensorId } STATUS current DESCRIPTION "This notification signifies the transition of the sensor state from critical to normal." ::= { benuChassisNotifObjects 6 } benuChassisPowerInfo OBJECT-TYPE SYNTAX INTEGER { powerSupplyA(1), powerSupplyB(2) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the location of the Power Failure or recovery." ::= { benuChassisNotifVariables 4 } benuChassisPowerFault NOTIFICATION-TYPE OBJECTS { benuChassisPowerInfo } STATUS current DESCRIPTION "A chassisPowerFaultTrap is generated when a Power Failure is detected in the system" ::= { benuChassisNotifObjects 7 } benuChassisPowerRecovery NOTIFICATION-TYPE OBJECTS { benuChassisPowerInfo } STATUS current DESCRIPTION "A chassisPowerRecoveryTrap is generated when a failed Power supply recovery is detected in the system" ::= { benuChassisNotifObjects 8 } benuChassisPowerPresent NOTIFICATION-TYPE OBJECTS { benuChassisPowerInfo } STATUS current DESCRIPTION "A chassisPowerPresentTrap is generated when a redundant Power supply is inserted in the system" ::= { benuChassisNotifObjects 9 } benuChassisPowerAbsent NOTIFICATION-TYPE OBJECTS { benuChassisPowerInfo } STATUS current DESCRIPTION "A chassisPowerAbsentTrap is generated when a redundant Power supply is removed from the system" ::= { benuChassisNotifObjects 10 } END