-- ****************************************************************************************** -- * -- * Description: Implements definitions for a HMS based network element -- * -- * Copyright 2014 by BKtel communications GmbH -- * -- * V.1.0 04.10.2006 M. Heldmann - created this "bkhmsne.mib" file based on BKtel systems "ahmsne.mib" file -- * - marked all parameters that are not used by NMS implementation of BKtel communications GmbH -- * - removed the 'ne' OID definition here and added 'ne' to IMPORTS -- * because the 'ne' is defined in root mib too -- * V.1.1 12.05.2014 M. Heldmann - marked all obsolete parameters as 'obsolete' - they may be no more supported by future NEC types and NEC software versions -- * - expanded neModulTable by full inventory information -- * - a couple of renamings -- * - changed name neModulType to neModuleModelName with SYNTAX DisplayString -- ****************************************************************************************** BKTEL-HFC862-HMSNE-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 ne, DisplayString, TruthValue, NESlotValue, PerceivedSeverityValue FROM BKTEL-HFC862-BASE-MIB ; neCommon OBJECT IDENTIFIER ::= { ne 1 } neType OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Type of NE" ::= { neCommon 1 } neDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The description of the NE." ::= { neCommon 2 } neLocationStreet OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Location Street of Network Element. Writable size depends on net element controller, default 32" ::= { neCommon 3 } neLocationCity OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Location City of Network Element. Writable size depends on net element controller, default 32" ::= { neCommon 4 } neObsolete_UsingAPS OBJECT-TYPE SYNTAX TruthValue ACCESS read-only STATUS obsolete DESCRIPTION "This parameter is obsolete." ::= { neCommon 5 } neObsolete_APSMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS obsolete DESCRIPTION "This parameter is obsolete." ::= { neCommon 6 } -- #####+1 Space reserved neObsolete_CommonSubrackWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "This parameter is obsolete. (The width of the Subracks)" ::= { neCommon 8 } neObsolete_CommonSubrackNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "This parameter is obsolete. (The number of Subracks)" ::= { neCommon 9 } neObsolete_NumberModul OBJECT-TYPE SYNTAX INTEGER (1..61) ACCESS read-only STATUS obsolete DESCRIPTION "This parameter is obsolete. (Current number of entries in the Modul table)" ::= { neCommon 10 } neObsolete_UsingRevertiveMode OBJECT-TYPE SYNTAX TruthValue ACCESS read-only STATUS obsolete DESCRIPTION "This parameter is obsolete." ::= { neCommon 11 } neObsolete_RevertiveMode OBJECT-TYPE SYNTAX INTEGER (0..300) ACCESS read-write STATUS obsolete DESCRIPTION "This parameter is obsolete." ::= { neCommon 12 } neObsolete_InitPhase OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "This parameter is obsolete." ::= { neCommon 13 } neObsolete_PredecessorRedundantPath OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS obsolete DESCRIPTION "This parameter is obsolete." ::= { neCommon 14 } neObsolete_PredecessorNominalPath OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS obsolete DESCRIPTION "This parameter is obsolete." ::= { neCommon 15 } neModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF NeModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table containing information about each Module." ::= { neCommon 16 } neModuleEntry OBJECT-TYPE SYNTAX NeModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of information about each Module." INDEX { neModuleNESlot } ::= { neModuleTable 1 } NeModuleEntry ::= SEQUENCE { neModuleNESlot NESlotValue, neModuleSubrack INTEGER, neModuleModelName DisplayString, neModuleMibLink OBJECT IDENTIFIER, neModuleSubrackSlot INTEGER, neModuleSlotUnitsUsed INTEGER, neModuleSlotRackDetection INTEGER, neModuleHousingType INTEGER, neModuleFirmwareVersion DisplayString, neModuleHardwareVersion DisplayString, neModuleDateOfProduction DisplayString, neModuleSerialNumber DisplayString, neModuleArticleNumber DisplayString, neModuleCustomerCode DisplayString, neModuleAliasName DisplayString, neModuleUserdata DisplayString, neModuleReset TruthValue, neModuleLedBlink TruthValue } neModuleNESlot OBJECT-TYPE -- former neNESlot SYNTAX NESlotValue ACCESS read-only STATUS mandatory DESCRIPTION "Slot number IMPORTANT NOTE: this is a not a physical slot within a module rack, but an assigned slot ID that uniquely identifies each module including non subrack based modules as 19 inch modules" ::= { neModuleEntry 1 } neModuleSubrack OBJECT-TYPE -- former neSubrack SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Subrack number in which the module is equiped (1 .. N). A value of 0 means: No subrack number" ::= { neModuleEntry 2 } neModuleModelName OBJECT-TYPE -- former neModulType SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Module model name" ::= { neModuleEntry 3 } neModuleMibLink OBJECT-TYPE -- former neModulMibLink SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "Defines the link to the OID of the equiped module" ::= { neModuleEntry 4 } -- Expansions, 12.05.2014 neModuleSubrackSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Slot number within subrack in which the module is equiped (1 .. N). A value of 0 means: No slot number" ::= { neModuleEntry 5 } neModuleSlotUnitsUsed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "For modules of type 'housing19inch(4)' this parameter specfifies the number of 19 inch height units used. For all other module types the number of slots within subrack which the module occupies." ::= { neModuleEntry 6 } neModuleSlotRackDetection OBJECT-TYPE SYNTAX INTEGER { notSupported(1), supported(2), detectionError(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Reports the state of modules slot and rack hardware detection." ::= { neModuleEntry 7 } neModuleHousingType OBJECT-TYPE SYNTAX INTEGER { housingUnknownOrDefault(1), housingBk(2), housing2G6(3), housing19inch(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Module housing type" ::= { neModuleEntry 8 } neModuleFirmwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Module firmware version" ::= { neModuleEntry 9 } neModuleHardwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Module hardware version" ::= { neModuleEntry 10 } neModuleDateOfProduction OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Module date of production, possible formats: - empty string -> no data defined - YYYY -> only the year of production is defined - YYYY-MM-DD -> full date of production is defined" ::= { neModuleEntry 11 } neModuleSerialNumber OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Module serial number" ::= { neModuleEntry 12 } neModuleArticleNumber OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Module article number" ::= { neModuleEntry 13 } neModuleCustomerCode OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Customer specific article code" ::= { neModuleEntry 14 } neModuleAliasName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Module alias name" ::= { neModuleEntry 15 } neModuleUserdata OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Module user data" ::= { neModuleEntry 16 } neModuleReset OBJECT-TYPE SYNTAX TruthValue ACCESS read-write STATUS mandatory DESCRIPTION "Resets the module if this parameter is written to true(1)." ::= { neModuleEntry 17 } neModuleLedBlink OBJECT-TYPE SYNTAX TruthValue ACCESS read-write STATUS mandatory DESCRIPTION "Writing this variable to true(1) lets the device's modul LED blink green for 10 seconds. Writing this variable to false(2) stops blinking at once. This variable always returns false(2) on read requests" ::= { neModuleEntry 18 } neStates OBJECT IDENTIFIER ::= { ne 2 } neStatesObsolete_TrapDisable OBJECT-TYPE SYNTAX PerceivedSeverityValue ACCESS read-only STATUS obsolete DESCRIPTION "This parameter is obsolete." ::= { neStates 1 } neStatesObsolete_TerminalConnected OBJECT-TYPE SYNTAX PerceivedSeverityValue ACCESS read-only STATUS obsolete DESCRIPTION "This parameter is obsolete." ::= { neStates 2 } -- #####+1 Space reserved neStatesObsolete_Isolated OBJECT-TYPE SYNTAX PerceivedSeverityValue ACCESS read-only STATUS obsolete DESCRIPTION "This parameter is obsolete." ::= { neStates 4 } neStatesObsolete_ResetModullist OBJECT-TYPE SYNTAX PerceivedSeverityValue ACCESS read-only STATUS obsolete DESCRIPTION "This parameter is obsolete." ::= { neStates 5 } neStatesObsolete_Redundant OBJECT-TYPE SYNTAX PerceivedSeverityValue ACCESS read-only STATUS obsolete DESCRIPTION "This parameter is obsolete." ::= { neStates 6 } neStatesObsolete_ActivateRedundantPath OBJECT-TYPE SYNTAX PerceivedSeverityValue ACCESS read-only STATUS obsolete DESCRIPTION "This parameter is obsolete." ::= { neStates 7 } neStatesObsolete_AutoOff OBJECT-TYPE SYNTAX PerceivedSeverityValue ACCESS read-only STATUS obsolete DESCRIPTION "This parameter is obsolete." ::= { neStates 8 } neConfig OBJECT IDENTIFIER ::= { ne 3 } neConfigObsolete_NEtype OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS obsolete DESCRIPTION "This parameter is obsolete." ::= { neConfig 1 } neConfigObsolete_IPaddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS obsolete DESCRIPTION "This parameter is obsolete." ::= { neConfig 2 } neConfigObsolete_Alarmdelay OBJECT-TYPE SYNTAX INTEGER (3..60) ACCESS read-write STATUS obsolete DESCRIPTION "This parameter is obsolete." ::= { neConfig 3 } neConfigDeprecated_MinTrapInterval OBJECT-TYPE SYNTAX INTEGER (0..10) ACCESS read-write STATUS optional DESCRIPTION "This parameter is deprecated. (The minimum waiting time between two traps. Only used for HMS070 over RS232 interface)" ::= { neConfig 4 } neConfigDeprecated_MaxTrapLifetime OBJECT-TYPE SYNTAX INTEGER (30..300) ACCESS read-write STATUS optional DESCRIPTION "This parameter is deprecated. (The maximum lifetime of a trap. Only used for HMS070 over RS232 interface)" ::= { neConfig 5 } neControl OBJECT IDENTIFIER ::= { ne 4 } neControlTrapDisable OBJECT-TYPE SYNTAX TruthValue ACCESS read-write STATUS mandatory DESCRIPTION "All traps and notifications for the whole NE are disabled: true(1) or enabled: false(2)" ::= { neControl 1 } neControlResetModullist OBJECT-TYPE SYNTAX TruthValue ACCESS read-write STATUS mandatory DESCRIPTION "This command removes all disconnected (not responding) modules from the module list." ::= { neControl 2 } neControlObsolete_SetDefaultAPS OBJECT-TYPE SYNTAX TruthValue ACCESS read-write STATUS obsolete DESCRIPTION "This parameter is obsolete." ::= { neControl 3 } -- This trap is obsolete and no more supported by new (2014) NECxE neSynchronizeEvent TRAP-TYPE ENTERPRISE ne DESCRIPTION "The SNMP trap that is generated when data on LMT must get actualized." ::= 1 END