BLUECOAT-SG-SENSOR-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32 FROM SNMPv2-SMI TEXTUAL-CONVENTION, TimeStamp, TruthValue, DisplayString FROM SNMPv2-TC blueCoatMgmt FROM BLUECOAT-MIB; deviceSensorMIB MODULE-IDENTITY LAST-UPDATED "201511260300Z" ORGANIZATION "Blue Coat Systems, Inc." CONTACT-INFO "support.services@bluecoat.com http://www.bluecoat.com" DESCRIPTION "The sensor MIB is used to monitor the values of sensors" REVISION "201511260300Z" DESCRIPTION "Add new value (notInstalled) to SensorStatus" REVISION "201307110300Z" DESCRIPTION "Access level for deviceSensorTrapEnabled changed." REVISION "200711050300Z" DESCRIPTION "Minor corrections and reformatting." REVISION "200211060300Z" DESCRIPTION "Initial revision of this MIB." ::= { blueCoatMgmt 1 } deviceSensorMIBObjects OBJECT IDENTIFIER ::= { deviceSensorMIB 1 } deviceSensorMIBNotifications OBJECT IDENTIFIER ::= { deviceSensorMIB 2 } deviceSensorMIBNotificationsPrefix OBJECT IDENTIFIER ::= { deviceSensorMIBNotifications 0 } -- textual conventions SensorUnits ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Sensor measurement unit types. Valid values are: other(1) - a measure other than those listed below. truthvalue(2) - value takes { true(1), false(2) }. specialEnum(3) - value takes user defined enumerated values. volts(4) - electrical potential. celsius(5) - temperature. rpm(6) - revolutions per minute." SYNTAX INTEGER { other(1), truthvalue(2), specialEnum(3), volts(4), celsius(5), rpm(6) } SensorCode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Interpretation of the current sensor value." SYNTAX INTEGER { ok(1), unknown(2), notInstalled(3), voltageLowWarning(4), voltageLowCritical(5), noPower(6), voltageHighWarning(7), voltageHighCritical(8), voltageHighSevere(9), temperatureHighWarning(10), temperatureHighCritical(11), temperatureHighSevere(12), fanSlowWarning(13), fanSlowCritical(14), fanStopped(15) } ExpBase10 ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "Exponent base 10 for the current sensor value. For example '-1' means value*(1/10)." SYNTAX Integer32 (-24..24) SensorValue ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "For sensors that measure volts and celsius, this item is a fixed point number. For sensors that measure rpm, this item can take only nonnegative values. For sensors of type truthvalue, this item can take only two values: true(1), false(2). For sensors of type specialEnum, this item can take any value." SYNTAX Integer32 (-1000000000..1000000000) SensorStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the operational status of the sensor. ok(1) means the agent can read the sensor value. unavailable(2) means that the agent presently can not report the sensor value. nonoperational(3) means that the sensor is broken. notInstalled(4) means that the sensor or device is not present." SYNTAX INTEGER { ok(1), unavailable(2), nonoperational(3), notInstalled(4) } -- -- MIB variables -- deviceSensorValues OBJECT IDENTIFIER ::= { deviceSensorMIBObjects 1 } -- -- deviceSensorValueTable -- deviceSensorValueTable OBJECT-TYPE SYNTAX SEQUENCE OF DeviceSensorValueEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of sensors." ::= { deviceSensorValues 1 } deviceSensorValueEntry OBJECT-TYPE SYNTAX DeviceSensorValueEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An deviceSensorValueTable entry describes the present reading of a sensor, the measurement units and sensor operational status." INDEX { deviceSensorIndex } ::= { deviceSensorValueTable 1 } DeviceSensorValueEntry ::= SEQUENCE { deviceSensorIndex INTEGER, deviceSensorTrapEnabled TruthValue, deviceSensorUnits SensorUnits, deviceSensorScale ExpBase10, deviceSensorValue SensorValue, deviceSensorCode SensorCode, deviceSensorStatus SensorStatus, deviceSensorTimeStamp TimeStamp, deviceSensorName DisplayString } deviceSensorIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary value which uniquely identifies the sensor" ::= { deviceSensorValueEntry 1 } deviceSensorTrapEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This variable controls generation of deviceSensorTrap for this sensor. When this variable is true(1), generation of deviceSensorTrap is enabled. When this variable is false(2), generation of deviceSensorTrap is disabled. The default start-up value is true(1)." ::= { deviceSensorValueEntry 2 } deviceSensorUnits OBJECT-TYPE SYNTAX SensorUnits MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the type of data reported by the deviceSensorValue. This variable is set by the agent at start-up and the value does not change during operation." ::= { deviceSensorValueEntry 3 } deviceSensorScale OBJECT-TYPE SYNTAX ExpBase10 MAX-ACCESS read-only STATUS current DESCRIPTION "Power of 10 to apply to the value reported by the deviceSensorValue. This variable is set by the agent at start-up and the value does not change during operation." ::= { deviceSensorValueEntry 4 } deviceSensorValue OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "This variable reports the most recent measurement seen by the sensor. To correctly display or interpret this variable's value, you must also know deviceSensorUnits." ::= { deviceSensorValueEntry 5 } deviceSensorCode OBJECT-TYPE SYNTAX SensorCode MAX-ACCESS read-only STATUS current DESCRIPTION "This variable reports how to interpret deviceSensorValue for the sensor." ::= { deviceSensorValueEntry 6 } deviceSensorStatus OBJECT-TYPE SYNTAX SensorStatus MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the present operational status of the sensor." ::= { deviceSensorValueEntry 7 } deviceSensorTimeStamp OBJECT-TYPE SYNTAX TimeStamp UNITS "Hundredths of seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the age of the value reported by deviceSensorValue." ::= { deviceSensorValueEntry 8 } deviceSensorName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The textual name of the sensor." ::= { deviceSensorValueEntry 9 } -- -- notifications -- deviceSensorTrap NOTIFICATION-TYPE OBJECTS { deviceSensorName, deviceSensorValue, deviceSensorCode } STATUS current DESCRIPTION "The sensor value warrants a notification." ::= { deviceSensorMIBNotificationsPrefix 1 } END