FOUNDRY-SN-POS-GROUP-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE,Counter32, Gauge32, Unsigned32,Integer32 FROM SNMPv2-SMI router FROM FOUNDRY-SN-ROOT-MIB ifIndex FROM IF-MIB DisplayString,TEXTUAL-CONVENTION FROM SNMPv2-TC; snPOS MODULE-IDENTITY LAST-UPDATED "201006020000Z" -- 04 June 2010 ORGANIZATION "Brocade Communications Systems, Inc." CONTACT-INFO "Technical Support Center 130 Holger Way, San Jose, CA 95134 Email: ipsupport@brocade.com Phone: 1-800-752-8061 URL: www.brocade.com" DESCRIPTION "Copyright 1996-2010 Brocade Communications Systems, Inc. All rights reserved. This Brocade Communications Systems SNMP Management Information Base Specification embodies Brocade Communications Systems' confidential and proprietary intellectual property. Brocade Communications Systems retains all title and ownership in the Specification, including any revisions. This Specification is supplied AS IS, and Brocade Communications Systems makes no warranty, either express or implied, as to the use, operation, condition, or performance of the specification, and any unintended consequence it may on the user environment." REVISION "201006020000Z" -- 04 June 2010 DESCRIPTION "Changed the ORGANIZATION, CONTACT-INFO and DESCRIPTION fields." REVISION "200909300000Z" -- September 30, 2009 DESCRIPTION "" ::= { router 14} -- textual conventions POSStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION " Status Values " SYNTAX INTEGER { disabled(0), enabled(1) } snPOSInfo OBJECT IDENTIFIER ::= { snPOS 1 } -- POS Port table information snPOSInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF SnPOSInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A specific snPOSInfo group consists of a number of switch ports. " ::= { snPOSInfo 1 } snPOSInfoEntry OBJECT-TYPE SYNTAX SnPOSInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the snPOSInfo table indicates the configuration on a specified port. A SNMP SET PDU for a row of the snPOSInfoTable requires the entired sequence of the MIB Objects in each snPOSInfoEntry stored in one PDU. Otherwise, GENERR return-value will be returned." INDEX { snPOSInfoPortNum } ::= { snPOSInfoTable 1 } SnPOSInfoEntry ::= SEQUENCE { snPOSInfoPortNum Integer32, snPOSIfIndex Integer32, snPOSDescr DisplayString, snPOSName DisplayString, snPOSInfoSpeed INTEGER, snPOSInfoAdminStatus INTEGER, snPOSInfoLinkStatus INTEGER, snPOSInfoClock INTEGER, snPOSInfoLoopBack INTEGER, snPOSInfoScrambleATM POSStatus, snPOSInfoFraming INTEGER, snPOSInfoCRC INTEGER, snPOSInfoKeepAlive INTEGER, snPOSInfoFlagC2 INTEGER, snPOSInfoFlagJ0 INTEGER, snPOSInfoFlagH1 INTEGER, snPOSStatsInFrames Counter32, snPOSStatsOutFrames Counter32, snPOSStatsAlignErrors Counter32, snPOSStatsFCSErrors Counter32, snPOSStatsFrameTooLongs Counter32, snPOSStatsFrameTooShorts Counter32, snPOSStatsInDiscard Counter32, snPOSStatsOutDiscard Counter32, snPOSInOctets OCTET STRING, snPOSOutOctets OCTET STRING, snPOSStatsInBitsPerSec Gauge32, snPOSStatsOutBitsPerSec Gauge32, snPOSStatsInPktsPerSec Gauge32, snPOSStatsOutPktsPerSec Gauge32, snPOSStatsInUtilization INTEGER , snPOSStatsOutUtilization INTEGER , snPOSTagType INTEGER, snPOSStatsB1 Counter32, snPOSStatsB2 Counter32, snPOSStatsB3 Counter32, snPOSStatsAIS Counter32, snPOSStatsRDI Counter32, snPOSStatsLOP Counter32, snPOSStatsLOF Counter32, snPOSStatsLOS Counter32 } snPOSInfoPortNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The port index. The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number (slot for chassis only)." ::= { snPOSInfoEntry 1 } snPOSIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "In order to identify a particular interface, this object shall identify the instance of the ifIndex object, defined in RFC 1213 and RFC 1573." ::= { snPOSInfoEntry 2 } snPOSDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string containing the slot/port information about the interface." ::= { snPOSInfoEntry 3 } snPOSName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "Port Name string." ::= { snPOSInfoEntry 4 } snPOSInfoSpeed OBJECT-TYPE SYNTAX INTEGER { s155000(1), s622000(2), other(3), s2488000(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The speed configuration for a port. The values are: 155000 622000 2488000 " ::= { snPOSInfoEntry 5 } snPOSInfoAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), -- ready to pass packets down(2), testing(3) -- in some test mode } MAX-ACCESS read-write STATUS current DESCRIPTION "The desired state of all ports. The testing(3) state indicates that no operational packets can be passed. (same as ifAdminStatus in MIB-II)" ::= { snPOSInfoEntry 6 } snPOSInfoLinkStatus OBJECT-TYPE SYNTAX INTEGER { up(1), -- ready to pass packets down(2), testing(3) -- in some test mode } MAX-ACCESS read-only STATUS current DESCRIPTION "The current operational state of the interface. The testing(3) state indicates that no operational packets can be passed. (same as ifOperStatus in MIB-II)" ::= { snPOSInfoEntry 7 } snPOSInfoClock OBJECT-TYPE SYNTAX INTEGER { internal(1), line(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock default internal" ::= { snPOSInfoEntry 8 } snPOSInfoLoopBack OBJECT-TYPE SYNTAX INTEGER { line(1), internal(2), none(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Loop back default none" ::= { snPOSInfoEntry 9 } snPOSInfoScrambleATM OBJECT-TYPE SYNTAX POSStatus MAX-ACCESS read-write STATUS current DESCRIPTION "ATM style scrambling default off" ::= { snPOSInfoEntry 10 } snPOSInfoFraming OBJECT-TYPE SYNTAX INTEGER { sonet(1), sdh(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Framing default SONET" ::= { snPOSInfoEntry 11 } snPOSInfoCRC OBJECT-TYPE SYNTAX INTEGER { crc32bits(1), crc16bits(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "CRC default 32 bit" ::= { snPOSInfoEntry 12 } snPOSInfoKeepAlive OBJECT-TYPE SYNTAX INTEGER (0..32767) MAX-ACCESS read-write STATUS current DESCRIPTION "Keep-alive default 10" ::= { snPOSInfoEntry 13 } snPOSInfoFlagC2 OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "C2 flag" ::= { snPOSInfoEntry 14 } snPOSInfoFlagJ0 OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "J0 flag" ::= { snPOSInfoEntry 15 } snPOSInfoFlagH1 OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "H1 flag" ::= { snPOSInfoEntry 16 } snPOSStatsInFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets received on the interface." ::= { snPOSInfoEntry 17 } snPOSStatsOutFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets transmitted out of the interface." ::= { snPOSInfoEntry 18 } snPOSStatsAlignErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "dot3StatsAlignmentErrors : A count of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check. The count represented by an instance of this object is incremented when the alignmentError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC." ::= { snPOSInfoEntry 19 } snPOSStatsFCSErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "dot3StatsFCSErrors : A count of frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check. The count represented by an instance of this object is incremented when the frameCheckError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC." ::= { snPOSInfoEntry 20 } snPOSStatsFrameTooLongs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "dot3StatsFrameTooLongs : A count of frames received on a particular interface that exceed the maximum permitted frame size. The count represented by an instance of this object is incremented when the frameTooLong status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC." ::= { snPOSInfoEntry 21 } snPOSStatsFrameTooShorts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " A count of frames received on a particular interface that below the minimum permitted frame size." ::= { snPOSInfoEntry 22 } snPOSStatsInDiscard OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space." ::= { snPOSInfoEntry 23 } snPOSStatsOutDiscard OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being transmitted. One possible reason for discarding such a packet could be to free up buffer space." ::= { snPOSInfoEntry 24 } snPOSInOctets OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of octets received on the interface, including framing characters. This object is a 64-bit counter of the ifInOctets object, defined in RFC 1213. The octet string is in big-endian byte order." ::= { snPOSInfoEntry 25 } snPOSOutOctets OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit counter of the ifOutOctets object, defined in RFC 1213. The octet string is in big-endian byte order." ::= { snPOSInfoEntry 26 } snPOSStatsInBitsPerSec OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bits per second received on the interface over a 5 minutes interval." ::= { snPOSInfoEntry 27 } snPOSStatsOutBitsPerSec OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bits per second transmitted out of the interface over a 5 minutes interval." ::= { snPOSInfoEntry 28 } snPOSStatsInPktsPerSec OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets per second received on the interface over a 5 minutes interval." ::= { snPOSInfoEntry 29 } snPOSStatsOutPktsPerSec OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets per second transmitted out of the interface over a 5 minutes interval." ::= { snPOSInfoEntry 30 } snPOSStatsInUtilization OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "The input network utilization in hundredths of a percent over a 5 minutes interval." ::= { snPOSInfoEntry 31 } snPOSStatsOutUtilization OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "The output network utilization in hundredths of a percent over a 5 minutes interval." ::= { snPOSInfoEntry 32 } snPOSTagType OBJECT-TYPE SYNTAX INTEGER { tagged(1), untagged(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "For tagged port, we could have multiple VLANs per port." ::= {snPOSInfoEntry 33} snPOSStatsB1 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Section error monitoring." ::= { snPOSInfoEntry 34 } snPOSStatsB2 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Line error monitoring." ::= { snPOSInfoEntry 35 } snPOSStatsB3 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Path error monitoring." ::= { snPOSInfoEntry 36 } snPOSStatsAIS OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm indication signal." ::= { snPOSInfoEntry 37 } snPOSStatsRDI OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Remote defect indication." ::= { snPOSInfoEntry 38 } snPOSStatsLOP OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of pointer." ::= { snPOSInfoEntry 39 } snPOSStatsLOF OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of frame." ::= { snPOSInfoEntry 40 } snPOSStatsLOS OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of signal." ::= { snPOSInfoEntry 41 } -- POS Port table information snPOSInfo2Table OBJECT-TYPE SYNTAX SEQUENCE OF SnPOSInfo2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An snPOSInfo2Table consists of a number of SnPOSInfo2Entry entries" ::= { snPOSInfo 2 } snPOSInfo2Entry OBJECT-TYPE SYNTAX SnPOSInfo2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the snPOSInfo2Table indicates the POS configuration on a specified port" INDEX { ifIndex } ::= { snPOSInfo2Table 1 } SnPOSInfo2Entry ::= SEQUENCE { snPOSInfo2Clock INTEGER, snPOSInfo2ScrambleATM POSStatus, snPOSInfo2CRC INTEGER, snPOSInfo2KeepAlive Unsigned32, snPOSInfo2FlagC2 Unsigned32, snPOSInfo2SSM INTEGER, snPOSInfo2Encapsulation INTEGER, snPOSInfo2AlarmMonitoring INTEGER, snPOSInfo2OverheadJ0ExpectedMessage OCTET STRING, snPOSInfo2OverheadJ0TransmitMessage OCTET STRING, snPOSInfo2OverheadJ1ExpectedMessage OCTET STRING, snPOSInfo2OverheadJ1MessageLength INTEGER, snPOSInfo2OverheadJ1TransmitMessage OCTET STRING } snPOSInfo2Clock OBJECT-TYPE SYNTAX INTEGER { internal(1), line(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock source for the POS Interface internal(1) - internal source line (2) - clocking is derived from line" DEFVAL { internal } ::= { snPOSInfo2Entry 1 } snPOSInfo2ScrambleATM OBJECT-TYPE SYNTAX POSStatus MAX-ACCESS read-write STATUS current DESCRIPTION "ATM style scrambling for the POS interface disabled(0) - scrambling is disabled enabled(1) - scrambling is enabled" DEFVAL { disabled } ::= { snPOSInfo2Entry 2 } snPOSInfo2CRC OBJECT-TYPE SYNTAX INTEGER { crc32bits(1), crc16bits(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Length of Cyclic Redundnacy Check (CRC) on the POS interface crc32bits(1) - 32 bits crc16bits(2) - 16 buts" DEFVAL { crc32bits } ::= { snPOSInfo2Entry 3 } snPOSInfo2KeepAlive OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Keep-alive timer for the POS interface in seconds" DEFVAL { 10 } ::= { snPOSInfo2Entry 4 } snPOSInfo2FlagC2 OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "C2 flag" ::= { snPOSInfo2Entry 5 } snPOSInfo2SSM OBJECT-TYPE SYNTAX INTEGER { t1SonetPrimaryReferenceSource(1) , t1SonetTraceabilityUnknown(2) , t1SonetStratum2Traceable(3) , t1SonetTransitNodeClock(4) , t1SonetStratum3eTraceable(5) , t1SonetStratum3Traceable(6) , t1SonetMinClockTraceable(7) , t1SonetDus(8) , e1SdhTraceabilityUnknown(9) , e1SdhSsmTransitNodeClockG812(10) , e1SdhDus(11) , e1SdhSsmPrimaryReferenceClockG811(12) , e1SdhSsmLocalG812(13) , e1SdhSsmSyncEquipmentTimingSource(14) } MAX-ACCESS read-write STATUS current DESCRIPTION "The S(ynchronization) S(tatus) M(essage) is sent over the SONET/SDH line to tell the other end about the quality of clock being sent over the line. t1SonetPrimaryReferenceSource(1) - SONET Primary Reference Source t1SonetTraceabilityUnknown(2} - SONET Traceability Unknown t1SonetStratum2Traceable(3) - SONET Stratum 2 Traceable t1SonetTransitNodeClock(4) - SONET Transit Node Clock t1SonetStratum3eTraceable(5) - SONET Stratum 3e Traceable t1SonetStratum3Traceable(6) - SONET Stratum 3 Traceable t1SonetMinClockTraceable(7) - SONET Minimum Clock Traceable t1SonetDus(8) - SONET Do not Use for Synchronization e1SdhTraceabilityUnknown(9) - SDH Traceability Unknown e1SdhSsmTransitNodeClockG812(10) - SDH Transit Node Clock G812 e1SdhDus(11) - SDH Do not Use for Synchronization e1SdhSsmPrimaryReferenceClockG811(12) - SDH Primary Reference Clock G811 e1SdhSsmLocalG812(13) - SDH Local G812 e1SdhSsmSyncEquipmentTimingSource(14) - SDH Synchronization Equipment Timing Source" DEFVAL { t1SonetTraceabilityUnknown } ::= { snPOSInfo2Entry 6 } snPOSInfo2Encapsulation OBJECT-TYPE SYNTAX INTEGER { ppp(1), hdlc(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Layer 2 encapsulation on the POS interface ppp(1) - Point to Point Protocol (PPP) hdlc(2) - Cisco High-level Data Link Control (cHDLC)" DEFVAL { ppp } ::= { snPOSInfo2Entry 7 } snPOSInfo2AlarmMonitoring OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Alarm Monitoring on POS interface off(0) - Alarm Monitoring is off on(1) - Alarm Montioring is on" DEFVAL { on } ::= { snPOSInfo2Entry 8 } snPOSInfo2OverheadJ0ExpectedMessage OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) MAX-ACCESS read-write STATUS current DESCRIPTION "Overhead J0 Expected Message" ::= { snPOSInfo2Entry 9 } snPOSInfo2OverheadJ0TransmitMessage OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) MAX-ACCESS read-write STATUS current DESCRIPTION "Overhead J0 Transmit Message" ::= { snPOSInfo2Entry 10 } snPOSInfo2OverheadJ1ExpectedMessage OBJECT-TYPE SYNTAX OCTET STRING (SIZE (16..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "Overhead J1 Expected Message" ::= { snPOSInfo2Entry 11 } snPOSInfo2OverheadJ1MessageLength OBJECT-TYPE SYNTAX INTEGER { s16 (16), s64 (64) } MAX-ACCESS read-write STATUS current DESCRIPTION "Overhead J1 Length of Message s16(16)...........16 bytes s64(64)............64 bytes" DEFVAL { s64 } ::= { snPOSInfo2Entry 12 } snPOSInfo2OverheadJ1TransmitMessage OBJECT-TYPE SYNTAX OCTET STRING (SIZE (16..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "Overhead J1 Transmit Message" ::= { snPOSInfo2Entry 13 } -- POS PPP Group -- If the L2 encapsulation is PPP, the following will provide -- information on the states of various control protocols snPOSPPPTable OBJECT-TYPE SYNTAX SEQUENCE OF SnPOSPPPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An snPOSPPPTable consists of a number of SnPOSPPPEntry entries" ::= { snPOSInfo 3 } snPOSPPPEntry OBJECT-TYPE SYNTAX SnPOSPPPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the snPOSPPPTable indicates the PPP control protocol status on a specified port" INDEX { ifIndex } ::= { snPOSPPPTable 1 } SnPOSPPPEntry ::= SEQUENCE { snPosPppLcp DisplayString, snPosPppIpCp DisplayString, snPosPppIpv6Cp DisplayString, snPosPppOsInLcp DisplayString, snPosPppMpLscp DisplayString } snPosPppLcp OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The PPP Link Control Protocol state" ::= { snPOSPPPEntry 1 } snPosPppIpCp OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The PPP IP Control Protocol state" ::= { snPOSPPPEntry 2 } snPosPppIpv6Cp OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The PPP IPv6 Control Protocol state" ::= { snPOSPPPEntry 3 } snPosPppOsInLcp OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The PPP OSI Network Layer Control Protocol state" ::= { snPOSPPPEntry 4 } snPosPppMpLscp OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The PPP MPLS Control Protocol state" ::= { snPOSPPPEntry 5 } -- POS cHDLC Group -- If the L2 encapsulation is cHDLC, the following will provide -- information various cHDLC paraemters snPOScHDLCTable OBJECT-TYPE SYNTAX SEQUENCE OF SnPOScHDLCEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An snPOScHDLCTable consists of a number of SnPOScHDLCEntry entries" ::= { snPOSInfo 4 } snPOScHDLCEntry OBJECT-TYPE SYNTAX SnPOScHDLCEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in snPOScHDLCEntry shows the cHDLC information on a specified port" INDEX { ifIndex } ::= { snPOScHDLCTable 1 } SnPOScHDLCEntry ::= SEQUENCE { snPOScHDLCLineState INTEGER, snPOScHDLCInLoopback INTEGER, snPOScHDLCMySeq Unsigned32, snPOScHDLCMySeqSeen Unsigned32, snPOScHDLCPeerSeqSeen Unsigned32, snPOScHDLCUniqueSent Unsigned32, snPOScHDLCUniqueReceived Unsigned32 } snPOScHDLCLineState OBJECT-TYPE SYNTAX INTEGER { down (0), up (1), unknown (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "cHDLC Line State" ::= { snPOScHDLCEntry 1 } snPOScHDLCInLoopback OBJECT-TYPE SYNTAX INTEGER { no (0), yes (1), unknown (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "cHDLC in loopback" ::= { snPOScHDLCEntry 2 } snPOScHDLCMySeq OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "cHDLC my sequence number" ::= { snPOScHDLCEntry 3 } snPOScHDLCMySeqSeen OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "cHDLC my sequence number seen" ::= { snPOScHDLCEntry 4 } snPOScHDLCPeerSeqSeen OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "cHDLC peer sequence number seen" ::= { snPOScHDLCEntry 5 } snPOScHDLCUniqueSent OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "cHDLC unique sent" ::= { snPOScHDLCEntry 6 } snPOScHDLCUniqueReceived OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "cHDLC unique received" ::= { snPOScHDLCEntry 7 } END -- ***************************************************************** -- Commited Access Rate MIB file. -- *****************************************************************