-- -- Title: Fibre Channel Switch MIB. -- -- This is specified based on SMIv2, mainly to ensure that the specification -- can be parsed easily by off-the-shelf network management product in -- the market. -- -- The goal of this mib is to access the any Fibre Channel switch of -- Brocade's family by using single SW-MIB file. -- This mib file includes the traps for Silkworm Switch. -- NOTE: Load BRCD.mib file before loading this mib file. -- SW-MIB DEFINITIONS ::= BEGIN IMPORTS DisplayString, TEXTUAL-CONVENTION FROM SNMPv2-TC Counter32, Integer32, IpAddress, OBJECT-TYPE, OBJECT-IDENTITY, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI FcWwn, SwDomainIndex, SwNbIndex, SwSensorIndex, SwPortIndex, SwTrunkMaster FROM Brocade-TC fcSwitch, bcsiModules FROM Brocade-REG-MIB connUnitPortStatEntry FROM FCMGMT-MIB; swMibModule MODULE-IDENTITY LAST-UPDATED "200408061830Z" -- Aug 06, 2004 6:30pm ORGANIZATION "Brocade Communications Systems, Inc.," CONTACT-INFO "Customer Support Group Brocade Communications Systems, 1745 Technology Drive, San Jose, CA 95110 U.S.A Tel: +1-408-392-6061 Fax: +1-408-392-6656 Email: support@Brocade.COM WEB: www.brocade.com" DESCRIPTION "The MIB module is for Brocade's Fibre Channel Switch. Copyright (c) 1996-2003 Brocade Communications Systems, Inc. All rights reserved." REVISION "200301131430Z" -- Jan 13, 2003 2:30pm DESCRIPTION "The initial version of this module." REVISION "200307201430Z" -- July 20, 2003 2:30pm DESCRIPTION "Added swIDIDMode to the swFabric group." REVISION "200404151030Z" -- April 15, 2004 10:30am DESCRIPTION "Added object for Trap Severity Level, swFwLastSeverityLevel. Added the enumeration swFwResourceFlash for SwFwClassesAreas. Deprecated the mib object swEventTrapLevel. Updated the description of swGroupId and corrected the spell mistakes. Obsoleted the swFault Trap. Added enumerations four-GB for swFCPortSpeed and unknown, other for swFCPortType." REVISION "200408061830Z" -- Aug 06, 2004 6:30pm DESCRIPTION "Added swFCPortSpecifier object to swFCPortTable." REVISION "200504292016Z" -- Apr 29, 2005 8:16pm DESCRIPTION "Modified the #SUMMARY and #ARGUMENTS for swFabricWatchTrap" REVISION "200601090900Z" -- Jan 09, 2006 9:00am DESCRIPTION "1. Modified the description for swPortTrunked 2. Updated the SW Traps summary and description to remove the obsolete varbindings" REVISION "200605170900Z" -- May 17, 2006 9:00am DESCRIPTION "Added swFCPortFlag object to swFCPortTable" REVISION "200701230900Z" -- Jan 23, 2007 9:00am DESCRIPTION "Added enumerations eight-GB and ten-GB for swFCPortSpeed" REVISION "200706081200Z" -- Jun 8, 2007 12:00pm DESCRIPTION "Included swFCPortFlag as an additiional variable binding for trap SWFCPortScn" REVISION "200706271030Z" -- Jun 27, 2007 10:30am DESCRIPTION "Added enumerations octuple and decuple for swNbBaudRate" REVISION "200708011220Z" -- Aug 01, 2007 12:20pm DESCRIPTION "Added the enumerations swFwEPortUtil and swFwEPortPktl for swFwClassAreaIndex" REVISION "200708290442Z" -- Aug 29, 2007 4:42pm DESCRIPTION "Added swFCPortBrcdType object to swFCPortTable" REVISION "200801290759Z" -- Jan 29, 2008 7:59pm DESCRIPTION "Added Toptalker support and swVfId to the swFabric group." REVISION "200807170345Z" -- July 17, 2008 3:45pm DESCRIPTION "Added swIPv6ChangeTrap, swIPv6Address and swIPv6Status ." REVISION "200807240232Z" -- July 24, 2008 2:32pm DESCRIPTION "Added swModel to distiguish between 7500 and 7500E switch ." REVISION "200807250232Z" -- July 25, 2008 2:32pm DESCRIPTION "Added the enumerations swFwPortLr, swFwEPortLr, swFwEPortUtil, swFwEPortPktl, swFwFCUPortLr, swFwFOPPortLr for swFwClassAreaIndex." REVISION "200809090900Z" -- Sept 09, 2008 9:00pm DESCRIPTION "Added swPmgrEventTrap information." REVISION "200909280900Z" -- Jan 28, 2009 9:00pm DESCRIPTION "Added additional fabric watch threshold in SwFwActs." REVISION "200902210900Z" -- Feb 21, 2008 9:00pm DESCRIPTION "Added port phy states." REVISION "200903300900Z" -- Mar 30, 2009 9:00am DESCRIPTION "Added swEventVfId in swEventTable." REVISION "200906251200Z" -- Jun 25, 2009 12:00pm DESCRIPTION "Removed the version information from Brocade's proprietary MIB file name." REVISION "200906290100Z" -- Jun 29, 2009 01:00pm DESCRIPTION "Modified swVfid position at the last of swFabric table" REVISION "200906301306Z" -- June 30, 2009 1:06pm DESCRIPTION "Added swFwCPUMemUsage enumeration under swFwClassAreaIndex." REVISION "200906300600Z" -- Jun 30, 2009 06:00pm DESCRIPTION "Updated the description of swCpuAction/swMemAction and access of swcpuormemoryusage objects and changed the type of swEndDeviceInvalidWord, swEndDeviceLinkFailure,swEndDeviceSyncLoss, swEndDeviceSigLoss, swEndDeviceProtoErr,swEndDeviceInvalidCRC from integer32 to counter32." REVISION "200910300500Z" -- Oct 30, 2009 05:00pm DESCRIPTION "Added swFabricReconfigTrap and swFabricSegmentTrap." REVISION "200911031306Z" -- Nov 03, 2009 1:06pm DESCRIPTION "Removed enum switchReboot from swAdmStatus." REVISION "200911051200Z" -- Nov 05, 2009 12:00pm DESCRIPTION "Changed swFwCustUnit access to read-only" REVISION "200911050500Z" -- Nov 05, 2009 05:00pm DESCRIPTION "Added enums swFwEPortTrunkUtil,swFwFCUPortTrunkUtil and swFwFOPPortTrunkUtil in SwFwClassesAreas" REVISION "200911061130Z" -- Nov 06, 2009 11:30am DESCRIPTION "Added swConnUnitExtensionTable and entries for 64 bit portstats." REVISION "0911301030Z" -- Nov 30, 2009 10:30am DESCRIPTION "Added swMemUsageLimit1 and swMemUsageLimit3 under swCpuOrMemoryUsage" REVISION "0912031730Z" -- Dec 03, 2009 05:30pm DESCRIPTION "Added swExttrap as internal trap." REVISION "1001301730Z" -- Jan 30, 2010 05:30pm DESCRIPTION "Changed the descriptions for swConnUnitExtensionTable as per latest FS." ::= { bcsiModules 3 } sw OBJECT-IDENTITY STATUS current DESCRIPTION "The OID sub-tree for Brocade's Silkworm Series of Fibre Channel Switches." ::= { fcSwitch 1 } sw28k OBJECT-IDENTITY STATUS current DESCRIPTION "The OID for Brocade's Silkworm 2800 model Fibre Channel Switch." ::= { fcSwitch 2 } sw21kN24k OBJECT-IDENTITY STATUS current DESCRIPTION "The OID for Brocade's Silkworm 2100 and 2400 series model Fibre Channel Switch." ::= { fcSwitch 3 } sw20x0 OBJECT-IDENTITY STATUS current DESCRIPTION "The OID for Brocade's Silkworm 20x0 series model Fibre Channel Switch." ::= { fcSwitch 4 } SwSevType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The event trap level in conjunction with the an event's severity level." SYNTAX INTEGER { none (0), critical (1), error (2), warning (3), informational (4), debug (5) } FcPortFlag ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the port status for a FC Flag. Currently this will indicate if the port is virtual or physical." SYNTAX BITS { physical (0), virtual (1) } -- various groups swSystem OBJECT-IDENTITY STATUS current DESCRIPTION "The OID sub-tree for swSystem group." ::= { sw 1 } swFabric OBJECT-IDENTITY STATUS current DESCRIPTION "The OID sub-tree for swFabric group." ::= { sw 2 } swModule OBJECT-IDENTITY STATUS current DESCRIPTION "The OID sub-tree for swModule group." ::= { sw 3 } swAgtCfg OBJECT-IDENTITY STATUS current DESCRIPTION "The OID sub-tree for swAgtCfg group." ::= { sw 4 } -- { sw 5 } is reserved swFCport OBJECT-IDENTITY STATUS current DESCRIPTION "The OID sub-tree for swFCport group." ::= { sw 6 } swNs OBJECT-IDENTITY STATUS current DESCRIPTION "The OID sub-tree for swNs group." ::= { sw 7 } swEvent OBJECT-IDENTITY STATUS current DESCRIPTION "The OID sub-tree for swEvent group." ::= { sw 8 } swFwSystem OBJECT-IDENTITY STATUS current DESCRIPTION "The OID sub-tree for swFwSystem group." ::= { sw 10 } swEndDevice OBJECT-IDENTITY STATUS current DESCRIPTION "The OID sub-tree for swEndDevice group." ::= { sw 21 } swGroup OBJECT-IDENTITY STATUS current DESCRIPTION "The OID sub-tree for swGroup group." ::= { sw 22 } swBlmPerfMnt OBJECT-IDENTITY STATUS current DESCRIPTION "The OID sub-tree for swBlmPerfMnt (Bloom Performance Monitor) group." ::= { sw 23 } swTrunk OBJECT-IDENTITY STATUS current DESCRIPTION "The OID sub-tree for swTrunk group." ::= { sw 24 } swTopTalker OBJECT-IDENTITY STATUS current DESCRIPTION "The OID sub-tree for TopTalker group." ::= { sw 25 } swCpuOrMemoryUsage OBJECT-IDENTITY STATUS current DESCRIPTION "The OID sub-tree for cpu or memory usage group." ::= { sw 26 } swConnUnitPortStatExtentionTable OBJECT-TYPE SYNTAX SEQUENCE OF SwConnUnitPortStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This represents the Conn unit Port Stats" ::= { sw 27 } -- -- the System Group (sw) -- swCurrentDate OBJECT-TYPE SYNTAX DisplayString(SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The current date information in displayable textual format." ::= { swSystem 1 } swBootDate OBJECT-TYPE SYNTAX DisplayString(SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The date and time when the system last booted, in displayable textual format." ::= { swSystem 2 } swFWLastUpdated OBJECT-TYPE SYNTAX DisplayString(SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The information indicates the date when the firmware was last updated, in displayable textual format." ::= { swSystem 3 } swFlashLastUpdated OBJECT-TYPE SYNTAX DisplayString(SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The information indicates the date when the FLASH was last updated, in displayable textual format." ::= { swSystem 4 } swBootPromLastUpdated OBJECT-TYPE SYNTAX DisplayString(SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The information indicates the date when the boot PROM was last updated, in displayable textual format." ::= { swSystem 5 } swFirmwareVersion OBJECT-TYPE SYNTAX DisplayString(SIZE (0..24)) MAX-ACCESS read-only STATUS current DESCRIPTION "The current version of the firwmare." ::= { swSystem 6 } swOperStatus OBJECT-TYPE SYNTAX INTEGER { online (1), offline (2), testing (3), faulty (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current operational status of the switch. The states are as follow: o online(1) means the switch is accessible by an external Fibre Channel port; o offline(2) means the switch is not accessible; o testing(3) means the switch is in a built-in test mode and is not accessible by an external Fibre Channel port; o faulty(4) means the switch is not operational." ::= { swSystem 7 } swAdmStatus OBJECT-TYPE SYNTAX INTEGER { online (1), offline (2), testing (3), faulty (4), reboot (5), fastboot (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "The desired administrative status of the switch. A management station may place the switch in a desired state by setting this object accordingly. The states are as follow: o online(1) means set the switch to be accessible by an external Fibre Channel port; o offline(2) means set the switch to be inaccessible; o testing(3) means set the switch to run the built-in test; o faulty(4) means set the switch to a 'soft' faulty condition; o reboot(5) means set the switch to reboot in 1 second. o fastboot(6) means set the switch to fastboot in 1 second. Fastboot would cause the switch to boot but skip over the POST. When the switch is in faulty state, only two states can be set: faulty and reboot/fastboot." ::= { swSystem 8 } swTelnetShellAdmStatus OBJECT-TYPE SYNTAX INTEGER { unknown (0), terminated (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The desired administrative status of the Telnet shell. By setting it to terminated(1), the current Telnet shell task is deleted. When this variable instance is read, it reports the value last set through SNMP." ::= { swSystem 9 } swSsn OBJECT-TYPE SYNTAX DisplayString(SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The soft serial number of the switch." ::= { swSystem 10 } -- FLASH administration -- the next 5 objects are related to firmware or config file management. -- -- The underlying method in the transfer of the firmware or config file -- is based on either FTP or remote shell. -- If a password is provided, then FTP is used. -- If NO password is provided, then remote shell is used. -- -- 2 steps to manage firmware or switch config file in the switch FLASH, -- (A1) set swFlashDLHost.0, swFlashDLUser.0 and swFlashDLFile.0 to -- appropriate -- host IP address in user dot notation (e.g. 192.168.1.7), -- user name (e.g. "administrator"), and -- file name of the firmware or config file (e.g. "/home/fcswh/v2.2") -- respectively; -- (A2) set swFlashDLPassword.0 to an appropriate value (e.g. "secret") -- if FTP is the desired method of transfer; -- (B) set swFlashDLAdmStatus.0 to swFwUpgrade(2), swCfUpload(3), -- or swCfDownload(4) accordingly. -- swFlashDLOperStatus OBJECT-TYPE SYNTAX INTEGER { unknown (0), swCurrent (1), swFwUpgraded (2), swCfUploaded (3), swCfDownloaded (4), swFwCorrupted (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operational status of the FLASH. The operational states are as follow: o swCurrent(1) indicates that the FLASH contains the current firmware image or config file; o swFwUpgraded(2) state indicates that it contains the image upgraded from the swFlashDLHost.0.; o swCfUploaded(3) state indicates that the switch configuration file has been uploaded to the host; and o swCfDownloaded(4) state indicates that the switch configuration file has been downloaded from the host. o swFwCorrupted (5) state indicates that the firmware in the FLASH of the switch is corrupted." ::= { swSystem 11 } swFlashDLAdmStatus OBJECT-TYPE SYNTAX INTEGER { swCurrent (1), swFwUpgrade (2), swCfUpload (3), swCfDownload (4), swFwCorrupted (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "The desired state of the FLASH. A management station may place the FLASH in a desired state by setting this object accordingly: o swCurrent(1) indicates that the FLASH contains the current firmware image or config file; o swFwUpgrade(2) means that the firmware in the FLASH is to be upgraded from the host specified; o swCfUpload(3) means that the switch config file is to be uploaded to the host specified; or o swCfDownload(4) means that the switch config file is to be downloaded from the host specified. o swFwCorrupted(5) state indicates that the firmware in the FLASH is corrupted. This value is for informational purpose only. However, set of swFlashDLAdmStatus to this value is not allowed. The host is specified in swFlashDLHost.0. In addition, user name is specified in swFlashDLUser.0, and the file name specified in swFlashDLFile.0. Reference the user manual on the following commands, o firmwareDownload, o configUpload, and o configDownload." ::= { swSystem 12 } swFlashDLHost OBJECT-TYPE SYNTAX DisplayString(SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name or IP address (in dot notation) of the host to download or upload a relevant file to the FLASH." ::= { swSystem 13 } swFlashDLUser OBJECT-TYPE SYNTAX DisplayString(SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The user name on the host to download or upload a relevant file to or from the FLASH." ::= { swSystem 14 } swFlashDLFile OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the file to be downloaded or uploaded." ::= { swSystem 15 } swFlashDLPassword OBJECT-TYPE SYNTAX DisplayString(SIZE (0..100)) MAX-ACCESS read-write STATUS current DESCRIPTION "The password to be used in for FTP transfer of files in the download or upload operation." ::= { swSystem 16 } -- 17..19 are reserved swBeaconOperStatus OBJECT-TYPE SYNTAX INTEGER { on (1), off (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current operational status of the switch beacon. When the beacon is on, the LEDs on the front panel of the switch run alternately from left to right and right to left. The color is yellow. When the beacon is off, each LED will be in their its regular status indicating color and state." ::= { swSystem 18 } swBeaconAdmStatus OBJECT-TYPE SYNTAX INTEGER { on (1), off (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The desired status of the switch beacon. When the beacon is set to on, the LEDs on the front panel of the switch run alternately from left to right and right to left. The color is yellow. When the beacon is set to off, each LED will be in its regular status indicating color and state." ::= { swSystem 19 } swDiagResult OBJECT-TYPE SYNTAX INTEGER { sw-ok (1), sw-faulty (2), sw-embedded-port-fault (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The result of the power-on startup (POST) diagnostics." ::= { swSystem 20 } -- operating environment sensors (temperature, fan, power supply...) swNumSensors OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of sensors inside the switch." ::= { swSystem 21 } swSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF SwSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of sensor entries." ::= { swSystem 22 } swSensorEntry OBJECT-TYPE SYNTAX SwSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the sensor information." INDEX { swSensorIndex } ::= { swSensorTable 1 } SwSensorEntry ::= SEQUENCE { swSensorIndex SwSensorIndex, swSensorType INTEGER, swSensorStatus INTEGER, swSensorValue Integer32, swSensorInfo DisplayString } swSensorIndex OBJECT-TYPE SYNTAX SwSensorIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the sensor." ::= { swSensorEntry 1 } swSensorType OBJECT-TYPE SYNTAX INTEGER { temperature (1), fan (2), power-supply (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the sensor type." ::= { swSensorEntry 2 } swSensorStatus OBJECT-TYPE SYNTAX INTEGER { unknown (1), faulty (2), below-min (3), nominal (4), above-max (5), absent (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of the sensor." ::= { swSensorEntry 3 } swSensorValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current value (reading) of the sensor. The value, -2147483648, represents an unknown quantity. It also means that the sensor does not have the capability to measure the actual value. In V2.0, the temperature sensor value will be in Celsius; the fan value will be in RPM (revolution per minute); and the power supply sensor reading will be unknown." ::= { swSensorEntry 4 } swSensorInfo OBJECT-TYPE SYNTAX DisplayString(SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Additional displayable information on the sensor. In V2.x, it contains the sensor type and number in textual format. For example, 'Temp 3', 'Fan 6'." ::= { swSensorEntry 5 } -- track changes string scalar swTrackChangesInfo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Track changes string. For trap only" ::= { swSystem 23 } swID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the logical switch (0/1)" ::= { swSystem 24 } swEtherIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP Address of the Ethernet interface of this logical switch." ::= { swSystem 25 } swEtherIPMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP Mask of the Ethernet interface of this logical switch." ::= { swSystem 26} swFCIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP Address of the FC interface of this logical switch." ::= { swSystem 27 } swFCIPMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP Mask of the FC interface of this logical switch." ::= { swSystem 28 } swIPv6Address OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS not-accessible STATUS current DESCRIPTION "IPV6 address." ::= { swSystem 29 } swIPv6Status OBJECT-TYPE SYNTAX INTEGER { tentative (1), preferred (2), ipdeprecated (3), inactive (4) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "The current status of ipv6 address." ::= { swSystem 30 } swModel OBJECT-TYPE SYNTAX INTEGER { switch7500 (1), switch7500E (2), other (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the switch is 7500 or 7500E ." ::= { swSystem 31 } swTestString OBJECT-TYPE SYNTAX DisplayString(SIZE(1..255)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "presence of this string represents test trap." ::= { swSystem 32 } -- -- End of System Group -- -- -- Fabric Group -- swDomainID OBJECT-TYPE SYNTAX SwDomainIndex MAX-ACCESS read-write STATUS current DESCRIPTION "The current Fibre Channel domain ID of the switch. To set a new value, the switch (swAdmStatus) must be in offline or testing state." ::= { swFabric 1 } swPrincipalSwitch OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates whether the switch is the Principal switch as per FC-SW." ::= { swFabric 2 } -- swFabric 3..7 are reserved -- (immediate) Neighborhood ISL family -- swNumNbs OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Inter-Switch Links in the (immediate) neighborhood." ::= { swFabric 8 } swNbTable OBJECT-TYPE SYNTAX SEQUENCE OF SwNbEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the ISLs in the immediate neighborhood of the switch." ::= { swFabric 9 } swNbEntry OBJECT-TYPE SYNTAX SwNbEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing each neighbor ISL parameters." INDEX { swNbIndex } ::= { swNbTable 1 } SwNbEntry ::= SEQUENCE { swNbIndex SwNbIndex, swNbMyPort SwPortIndex, swNbRemDomain SwDomainIndex, swNbRemPort SwPortIndex, swNbBaudRate INTEGER, swNbIslState INTEGER, swNbIslCost Integer32, swNbRemPortName OCTET STRING } swNbIndex OBJECT-TYPE SYNTAX SwNbIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the neighbor ISL entry." ::= { swNbEntry 1 } swNbMyPort OBJECT-TYPE SYNTAX SwPortIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This is the port that has an ISL to another switch." ::= { swNbEntry 2 } swNbRemDomain OBJECT-TYPE SYNTAX SwDomainIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This is the Fibre Channel domain on the other end of the ISL." ::= { swNbEntry 3 } swNbRemPort OBJECT-TYPE SYNTAX SwPortIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This is the port index on the other end of the ISL." ::= { swNbEntry 4 } swNbBaudRate OBJECT-TYPE SYNTAX INTEGER { other (1), -- none of below oneEighth (2), -- 155 Mbaud quarter (4), -- 266 Mbaud half (8), -- 532 Mbaud full (16), -- 1 Gbaud double (32), -- 2 Gbaud quadruple (64), -- 4 Gbaud octuple (128), -- 8 Gbaud decuple (256) -- 10 Gbaud } MAX-ACCESS read-only STATUS current DESCRIPTION "The baud rate of the ISL." ::= { swNbEntry 5 } swNbIslState OBJECT-TYPE SYNTAX INTEGER { sw-down (0), sw-init (1), sw-internal2 (2), sw-internal3 (3), sw-internal4 (4), sw-active (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the ISL. The swNbIslState will be 0 when ISL is in incompatible state or port is a slave port." ::= { swNbEntry 6 } swNbIslCost OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The current link cost of the ISL." ::= { swNbEntry 7 } swNbRemPortName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The World_wide_Name of the remote port." ::= { swNbEntry 8 } -- Fabric member information -- swFabricMemTable OBJECT-TYPE SYNTAX SEQUENCE OF SwFabricMemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains information on the member switches of a fabric. This may not be available on all versions of Fabric OS." ::= { swFabric 10 } swFabricMemEntry OBJECT-TYPE SYNTAX SwFabricMemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing each switch in the fabric." INDEX { swFabricMemWwn } ::= { swFabricMemTable 1 } SwFabricMemEntry ::= SEQUENCE { swFabricMemWwn FcWwn, swFabricMemDid SwDomainIndex, swFabricMemName DisplayString, swFabricMemEIP IpAddress, swFabricMemFCIP IpAddress, swFabricMemGWIP IpAddress, swFabricMemType Integer32, swFabricMemShortVersion OCTET STRING } swFabricMemWwn OBJECT-TYPE SYNTAX FcWwn MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the World wide name of the member switch." ::= { swFabricMemEntry 1 } swFabricMemDid OBJECT-TYPE SYNTAX SwDomainIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the domain id of the member switch." ::= { swFabricMemEntry 2 } swFabricMemName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the name of the member switch." ::= { swFabricMemEntry 3 } swFabricMemEIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the ethernet IP address of the member switch." ::= { swFabricMemEntry 4 } swFabricMemFCIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the Fibre Channel IP address of the member switch." ::= { swFabricMemEntry 5 } swFabricMemGWIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the Gateway IP address of the member switch." ::= { swFabricMemEntry 6 } swFabricMemType OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the member switch type." ::= { swFabricMemEntry 7 } swFabricMemShortVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..24)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies Fabric OS version of the member switch." ::= { swFabricMemEntry 8 } swIDIDMode OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of Insistent Domain ID (IDID) mode. Status indicating IDID mode is enabled or not." ::= { swFabric 11 } swPmgrEventType OBJECT-TYPE SYNTAX INTEGER { create (0), delete (1), moveport (2), fidchange (3), basechange (4), vfstatechange(6) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates Partition manager event type." ::= { swFabric 12 } swPmgrEventTime OBJECT-TYPE SYNTAX DisplayString(SIZE (0..64)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object identifies the date and time when this pmgr event occurred, in textual format." ::= { swFabric 13 } swPmgrEventDescr OBJECT-TYPE SYNTAX DisplayString(SIZE (0..64)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object identifies the textual description of the pmgr event." ::= { swFabric 14 } swVfId OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The Virtual fabric id." ::= { swFabric 15 } -- -- SNMP Agent Configuration -- -- swAgtCfg 1..10 are reserved swAgtCmtyTable OBJECT-TYPE SYNTAX SEQUENCE OF SwAgtCmtyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each Community, the access control and parameters of the Community." ::= { swAgtCfg 11 } swAgtCmtyEntry OBJECT-TYPE SYNTAX SwAgtCmtyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing the Community parameters." INDEX { swAgtCmtyIdx } ::= { swAgtCmtyTable 1 } SwAgtCmtyEntry ::= SEQUENCE { swAgtCmtyIdx Integer32, swAgtCmtyStr DisplayString, swAgtTrapRcp IpAddress, swAgtTrapSeverityLevel SwSevType } swAgtCmtyIdx OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the SNMPv1 Community entry." ::= { swAgtCmtyEntry 1 } swAgtCmtyStr OBJECT-TYPE SYNTAX DisplayString(SIZE (2..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a Community string supported by the agent. If a new value is set successfully, it takes effect immediately." ::= { swAgtCmtyEntry 2 } swAgtTrapRcp OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This is the trap recipient associated with the Community. If a new value is set successfully, it takes effect immediately." ::= { swAgtCmtyEntry 3 } swAgtTrapSeverityLevel OBJECT-TYPE SYNTAX SwSevType MAX-ACCESS read-write STATUS current DESCRIPTION "This is the trap severity level associated with the swAgtTrapRcp. The trap severity level in conjunction with the an event's severity level. When an event occurs and if its severity level is at or below the set value, the SNMP trap is sent to configured trap recipients. The severity level is limited to particular events. If a new value is set successfully, it takes effect immediately." ::= { swAgtCmtyEntry 4 } -- -- End of SNMP Agent Configuration Group -- -- -- Fibre Channel Port Group -- This group contains information about the physical state, -- operational status, performance and error statistics of each -- Fibre Channel port on the switch. A Fibre Channel port is one which -- supports the Fibre Channel protocol. E.g. F_Port, E_Port, FL_Port. -- swFCPortCapacity OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of Fibre Channel ports on this switch. It includes G_Port, F_Port, FL_Port and any other types of Fibre Channel port." ::= { swFCport 1 } swFCPortTable OBJECT-TYPE SYNTAX SEQUENCE OF SwFCPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains, one entry for each switch port, configuration and service parameters of the port." ::= { swFCport 2 } swFCPortEntry OBJECT-TYPE SYNTAX SwFCPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing the configuration and service parameters of the switch port." INDEX { swFCPortIndex } ::= { swFCPortTable 1 } SwFCPortEntry ::= SEQUENCE { swFCPortIndex SwPortIndex, swFCPortType INTEGER, swFCPortPhyState INTEGER, swFCPortOpStatus INTEGER, swFCPortAdmStatus INTEGER, swFCPortLinkState INTEGER, swFCPortTxType INTEGER, -- the rest is mapped to gstat_t swFCPortTxWords Counter32, swFCPortRxWords Counter32, swFCPortTxFrames Counter32, swFCPortRxFrames Counter32, swFCPortRxC2Frames Counter32, swFCPortRxC3Frames Counter32, swFCPortRxLCs Counter32, swFCPortRxMcasts Counter32, swFCPortTooManyRdys Counter32, swFCPortNoTxCredits Counter32, swFCPortRxEncInFrs Counter32, swFCPortRxCrcs Counter32, swFCPortRxTruncs Counter32, swFCPortRxTooLongs Counter32, swFCPortRxBadEofs Counter32, swFCPortRxEncOutFrs Counter32, swFCPortRxBadOs Counter32, swFCPortC3Discards Counter32, swFCPortMcastTimedOuts Counter32, swFCPortTxMcasts Counter32, -- LIP statistics swFCPortLipIns Counter32, swFCPortLipOuts Counter32, swFCPortLipLastAlpa OCTET STRING, -- new for V2.1 swFCPortWwn OCTET STRING, -- new for V3.0 swFCPortSpeed INTEGER, -- new for Port Name Feature. swFCPortName DisplayString, -- new for PortSpecifier Feature. swFCPortSpecifier DisplayString, -- new for portFlag Feature. swFCPortFlag FcPortFlag, -- Brocade port type. swFCPortBrcdType INTEGER } swFCPortIndex OBJECT-TYPE SYNTAX SwPortIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the switch port index. Note that the value of a port index is 1 higher than the port number labeled on the front panel. E.g. port index 1 correspond to port number 0." ::= { swFCPortEntry 1 } swFCPortType OBJECT-TYPE SYNTAX INTEGER { stitch (1), flannel (2), loom (3), bloom (4), rdbloom (5), wormhole (6), other (7), unknown (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the type of switch port. It may be of type stitch(1), flannel(2), loom(3) , bloom(4),rdbloom(5) or wormhole(6)." ::= { swFCPortEntry 2 } swFCPortPhyState OBJECT-TYPE SYNTAX INTEGER { noCard (1), noTransceiver (2), laserFault (3), noLight (4), noSync (5), inSync (6), portFault (7), diagFault (8), lockRef (9), validating (10), invalidModule (11), unknown (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the physical state of the port: noCard(1) no card present in this switch slot; noTransceiver(2) no Transceiver module in this port. noGbic(2) was used previously. Transceiver is the generic name for GBIC, SFP etc.; laserFault(3) the module is signaling a laser fault (defective Transceiver); noLight(4) the module is not receiving light; noSync(5) the module is receiving light but is out of sync; inSync(6) the module is receiving light and is in sync; portFault(7) the port is marked faulty (defective Transceiver, cable or device); diagFault(8) the port failed diagnostics (defective G_Port or FL_Port card or motherboard); lockRef(9) the port is locking to the reference signal. validating(10) Validation is in progress invalidModule(11) Invalid SFP unknown(255) unknown. " ::= { swFCPortEntry 3 } swFCPortOpStatus OBJECT-TYPE SYNTAX INTEGER { unknown (0), online (1), offline (2), testing (3), faulty (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the operational status of the port. The online(1) state indicates that user frames can be passed. The unknown(0) state indicates that likely the port module is physically absent (see swFCPortPhyState)." ::= { swFCPortEntry 4 } swFCPortAdmStatus OBJECT-TYPE SYNTAX INTEGER { online (1), offline (2), testing (3), faulty (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The desired state of the port. A management station may place the port in a desired state by setting this object accordingly. The testing(3) state indicates that no user frames can be passed. As the result of either explicit management action or per configuration information accessible by the switch, swFCPortAdmStatus is then changed to either the online(1) or testing(3) states, or remains in the offline(2) state." ::= { swFCPortEntry 5 } swFCPortLinkState OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2), loopback (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the link state of the port. The value may be: enabled(1) - port is allowed to participate in the FC-PH protocol with its attached port (or ports if it is in a FC-AL loop); disabled(2) - the port is not allowed to participate in the FC-PH protocol with its attached port(s); loopback(3) - the port may transmit frames through an internal path to verify the health of the transmitter and receiver path. Note that when the port's link state changes, its operational status (swFCPortOpStatus) will be affected." ::= { swFCPortEntry 6 } swFCPortTxType OBJECT-TYPE SYNTAX INTEGER { unknown (1), lw (2), sw (3), ld (4), cu (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the media transmitter type of the port. The value may be: unknown(1) cannot determined to the port driver lw(2) long wave laser sw(3) short wave laser ld(4) long wave LED cu(5) copper (electrical)." ::= { swFCPortEntry 7 } -- counters swFCPortTxWords OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of Fibre Channel words that the port has transmitted." ::= { swFCPortEntry 11 } swFCPortRxWords OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of Fibre Channel words that the port has received." ::= { swFCPortEntry 12 } swFCPortTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of (Fibre Channel) frames that the port has transmitted." ::= { swFCPortEntry 13 } swFCPortRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of (Fibre Channel) frames that the port has received." ::= { swFCPortEntry 14 } swFCPortRxC2Frames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of Class 2 frames that the port has received." ::= { swFCPortEntry 15 } swFCPortRxC3Frames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of Class 3 frames that the port has received." ::= { swFCPortEntry 16 } swFCPortRxLCs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of Link Control frames that the port has received." ::= { swFCPortEntry 17 } swFCPortRxMcasts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of Multicast frames that the port has received." ::= { swFCPortEntry 18 } swFCPortTooManyRdys OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of times when RDYs exceeds the frames received." ::= { swFCPortEntry 19 } swFCPortNoTxCredits OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of times when the transmit credit has reached zero." ::= { swFCPortEntry 20 } swFCPortRxEncInFrs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of encoding error or disparity error inside frames received." ::= { swFCPortEntry 21 } swFCPortRxCrcs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of CRC errors detected for frames received." ::= { swFCPortEntry 22 } swFCPortRxTruncs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of truncated frames that the port has received." ::= { swFCPortEntry 23 } swFCPortRxTooLongs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of received frames that are too long." ::= { swFCPortEntry 24 } swFCPortRxBadEofs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of received frames that have bad EOF delimiter." ::= { swFCPortEntry 25 } swFCPortRxEncOutFrs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of encoding error or disparity error outside frames received." ::= { swFCPortEntry 26 } swFCPortRxBadOs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of invalid Ordered Sets received." ::= { swFCPortEntry 27 } swFCPortC3Discards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of Class 3 frames that the port has discarded." ::= { swFCPortEntry 28 } swFCPortMcastTimedOuts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of Multicast frames that has been timed out." ::= { swFCPortEntry 29 } swFCPortTxMcasts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of Multicast frames that has been transmitted." ::= { swFCPortEntry 30 } -- LIP statistics swFCPortLipIns OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of Loop Initializations that has been initiated by loop devices attached." ::= { swFCPortEntry 31 } swFCPortLipOuts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object counts the number of Loop Initializations that has been initiated by the port." ::= { swFCPortEntry 32 } swFCPortLipLastAlpa OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Physical Address (AL_PA) of the loop device that initiated the last Loop Initialization." ::= { swFCPortEntry 33 } swFCPortWwn OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The World_wide_Name of the Fibre Channel port. The contents of an instance are in the IEEE extended format as specified in FC-PH; the 12-bit port identifier represents the port number within the switch." ::= { swFCPortEntry 34 } swFCPortSpeed OBJECT-TYPE SYNTAX INTEGER { one-GB (1), two-GB (2), auto-Negotiate (3), four-GB (4), eight-GB (5), ten-GB (6), unknown (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "The desired baud rate for the port. It can have the values of 1GB (1), 2GB (2), Auto-Negotiate (3), 4GB (4), 8GB (5), or 10GB (6). Some of the above values may not be supported by all type of switches." ::= { swFCPortEntry 35 } swFCPortName OBJECT-TYPE SYNTAX DisplayString(SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "A string indicates the name of the addressed port. The names should be persistent across switch reboots. Port names do not have to be unique within a switch or within a fabric." ::= { swFCPortEntry 36 } swFCPortSpecifier OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This string indicates the physical port number of the addressed port. The format of the string is: /port, where 'slot' being present only for bladed systems. " ::= { swFCPortEntry 37 } -- FC port status flag swFCPortFlag OBJECT-TYPE SYNTAX FcPortFlag MAX-ACCESS read-only STATUS current DESCRIPTION "A bit map of port status flags which includes the information of port type. Currently this will indicate if the port is virtual or physical." ::= { swFCPortEntry 38 } swFCPortBrcdType OBJECT-TYPE SYNTAX INTEGER { unknown (1), other (2), fl-port (3), -- public loop f-port (4), -- fabric port e-port (5), -- fabric expansion port g-port (6), -- generic fabric port ex-port (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Brocade port type." ::= { swFCPortEntry 39 } -- -- End of Fibre Channel Port group -- -- -- The Name Server Database group -- swNsLocalNumEntry OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of local Name Server entries." ::= { swNs 1 } swNsLocalTable OBJECT-TYPE SYNTAX SEQUENCE OF SwNsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of local Name Server entries." ::= { swNs 2 } swNsLocalEntry OBJECT-TYPE SYNTAX SwNsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the local Name Server database." INDEX { swNsEntryIndex } ::= { swNsLocalTable 1 } SwNsEntry ::= SEQUENCE { swNsEntryIndex Integer32, swNsPortID OCTET STRING, swNsPortType INTEGER, swNsPortName FcWwn, swNsPortSymb OCTET STRING, swNsNodeName FcWwn, swNsNodeSymb OCTET STRING, swNsIPA OCTET STRING, swNsIpAddress OCTET STRING, swNsCos INTEGER, swNsFc4 OCTET STRING, swNsIpNxPort OCTET STRING, swNsWwn OCTET STRING, swNsHardAddr OCTET STRING } swNsEntryIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The object identifies the Name Server database entry." ::= { swNsLocalEntry 1 } swNsPortID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The object identifies the Fibre Channel port address ID of the entry." ::= { swNsLocalEntry 2 } swNsPortType OBJECT-TYPE SYNTAX INTEGER { -- unknown (0), nPort (1), nlPort (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The object identifies the type of port: N_Port, NL_Port, etc., for this entry. The type is defined in FC-GS-2." ::= { swNsLocalEntry 3 } swNsPortName OBJECT-TYPE SYNTAX FcWwn MAX-ACCESS read-only STATUS current DESCRIPTION "The object identifies the Fibre Channel World_wide Name of the port entry." ::= { swNsLocalEntry 4 } swNsPortSymb OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The object identifies the contents of a Symbolic Name of the port entry. In FC-GS-2, a Symbolic Name consists of a byte array of 1 through 255 bytes, and the first byte of the array specifies the length of its 'contents'. This object variable corresponds to the 'contents' of the Symbolic Name, without the first byte." ::= { swNsLocalEntry 5 } swNsNodeName OBJECT-TYPE SYNTAX FcWwn MAX-ACCESS read-only STATUS current DESCRIPTION "The object identifies the Fibre Channel World_wide Name of the associated node as defined in FC-GS-2." ::= { swNsLocalEntry 6 } swNsNodeSymb OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The object identifies the contents of a Symbolic Name of the the node associated with the entry. In FC-GS-2, a Symbolic Name consists of a byte array of 1 through 255 bytes, and the first byte of the array specifies the length of its 'contents'. This object variable corresponds to the 'contents' of the Symbolic Name, without the first byte (specifying the length)." ::= { swNsLocalEntry 7 } swNsIPA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The object identifies the Initial Process Associator of the node for the entry as defined in FC-GS-2." ::= { swNsLocalEntry 8 } swNsIpAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The object identifies the IP address of the node for the entry as defined in FC-GS-2. The format of the address is in IPv6." ::= { swNsLocalEntry 9 } swNsCos OBJECT-TYPE SYNTAX INTEGER { -- class-unknown (0), class-F (1), class-1 (2), class-F-1 (3), class-2 (4), class-F-2 (5), class-1-2 (6), class-F-1-2 (7), class-3 (8), class-F-3 (9), class-1-3 (10), class-F-1-3 (11), class-2-3 (12), class-F-2-3 (13), class-1-2-3 (14), class-F-1-2-3 (15) -- more to enumerate in future. } MAX-ACCESS read-only STATUS current DESCRIPTION "The object identifies the class of services supported by the port. The value is a bit-map defined as follows: o bit 0 is class F, o bit 1 is class 1, o bit 2 is class 2, o bit 3 is class 3, o bit 4 is class 4, etc." ::= { swNsLocalEntry 10 } swNsFc4 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The object identifies the FC-4s supported by the port as defined in FC-GS-2." ::= { swNsLocalEntry 11 } swNsIpNxPort OBJECT-TYPE SYNTAX OCTET STRING (SIZE(16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The object identifies IpAddress of the Nx_port for the entry." ::= { swNsLocalEntry 12 } swNsWwn OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The object identifies the World Wide Name (WWN) of the Fx_port for the entry." ::= { swNsLocalEntry 13 } swNsHardAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) MAX-ACCESS read-only STATUS current DESCRIPTION "The object identifies the 24-bit hard address of the node for the entry." ::= { swNsLocalEntry 14 } -- -- End of Fibre Channel Name Server group -- -- ####################################################################### -- -- Event Group - to map the errLog -- -- NOTE -- Logically, swEventTable is separate from the error log since it is -- essentially a view of the error log within a particular time window. -- The value of swEventIndex shall indicate the event number that has -- occurred since the switch booted. The value will range from 1 through -- 2147383647 (2^31 - 1). -- -- ####################################################################### swEventTrapLevel OBJECT-TYPE SYNTAX INTEGER { none (0), critical (1), error (2), warning (3), informational (4), debug (5) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "swAgtTrapSeverityLevel, in absence of swEventTrapLevel, specifies the Trap Severity Level of each defined trap recipient host. This object specifies the swEventTrap level in conjunction with an event's severity level. When an event occurs and if its severity level is at or below the value specified by this object instance, the agent will send the associated swEventTrap to configured recipients." ::= { swEvent 1 } -- { swEvent 2..3 are reserved } swEventNumEntries OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of entries in the Event Table." ::= { swEvent 4 } swEventTable OBJECT-TYPE SYNTAX SEQUENCE OF SwEventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of event entries." ::= { swEvent 5 } swEventEntry OBJECT-TYPE SYNTAX SwEventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the event table." INDEX { swEventIndex } ::= { swEventTable 1 } SwEventEntry ::= SEQUENCE { swEventIndex Integer32, swEventTimeInfo DisplayString, swEventLevel INTEGER, swEventRepeatCount Integer32, swEventDescr DisplayString, swEventVfId Integer32 } swEventIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the event entry." ::= { swEventEntry 1 } swEventTimeInfo OBJECT-TYPE SYNTAX DisplayString(SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the date and time when this event occurred, in textual format." ::= { swEventEntry 2 } swEventLevel OBJECT-TYPE SYNTAX INTEGER { critical (1), error (2), warning (3), informational (4), debug (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the severity level of this event entry." ::= { swEventEntry 3 } swEventRepeatCount OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies how many times this particular event has occurred." ::= { swEventEntry 4 } swEventDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the textual description of the event." ::= { swEventEntry 5 } swEventVfId OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the Virtual fabric id." ::= { swEventEntry 6 } -- -- End of Fibre Channel Event Group -- -- -- swFwSystem -- Fabric Watch subsystem -- ########################################################################### -- Fabric Watch subsystem consists of two tables -- SwFwClassAreaEntry contains control information for a particular class/area's -- thresholds. These thresholds are contained in SwFwThresholdEntry. -- ########################################################################### -- valid action matrix -- ########################################################################### -- The valid action matrix is arrived out of the combination of the configured -- alarm matrix such as Errlog-1(El), SnmpTrap-2(St), PortLogLock-4(Pl), -- RapiTrap-8(Rn), EmailAlert-16, PortFencing-32(Pf) -- ########################################################################### SwFwActs ::= INTEGER { swFwNoAction(0), swFwErrlog(1), swFwSnmptrap(2), swFwErrlogSnmptrap(3), swFwPortloglock(4), swFwErrlogPortloglock(5), swFwSnmptrapPortloglock(6), swFwErrlogSnmptrapPortloglock(7), swFwRn(8), swFwElRn(9), swFwStRn(10), swFwElStRn(11), swFwPlRn(12), swFwElPlRn(13), swFwStPlRn(14), swFwElStPlRn(15), swFwMailAlert(16), swFwMailAlertErrlog(17), swFwMailAlertSnmptrap(18), swFwMailAlertErrlogSnmptrap(19), swFwMailAlertPortloglock(20), swFwMailAlertErrlogPortloglock(21), swFwMailAlertSnmptrapPortloglock(22), swFwMailAlertErrlogSnmptrapPortloglock(23), swFwMailAlertRn(24), swFwElMailAlertRn(25), swFwMailAlertStRn(26), swFwMailAlertElStRn(27), swFwMailAlertPlRn(28), swFwMailAlertElPlRn(29), swFwMailAlertStPlRn(30), swFwMailAlertElStPlRn(31), swFwPf(32), swFwElPf(33), swFwStPf(34), swFwElStPf(35), swFwPlPf(36), swFwElPlPf(37), swFwStPlPf(38), swFwElStPlPf(39), swFwRnPf(40), swFwElRnPf(41), swFwStRnPf(42), swFwElStRnPf(43), swFwPlRnPf(44), swFwElPlRnPf(45), swFwStPlRnPf(46), swFwElStPlRnPf(47), swFwMailAlertPf(48), swFwMailAlertElPf(49), swFwMailAlertStPf(50), swFwMailAlertElStPf(51), swFwMailAlertPlPf(52), swFwMailAlertElPlPf(53), swFwMailAlertStPlPf(54), swFwMailAlertElStPlPf(55), swFwMailAlertRnPf(56), swFwMailAlertElRnPf(57), swFwMailAlertStRnPf(58), swFwMailAlertElStRnPf(59), swFwMailAlertPlRnPf(60), swFwMailAlertElPlRnPf(61), swFwMailAlertStPlRnPf(62), swFwMailAlertElStPlRnPf(63) } -- variable for threshold values or action matrix level SwFwLevels ::= INTEGER { swFwReserved(1), swFwDefault(2), swFwCustom(3) } -- classes and areas index SwFwClassesAreas ::= INTEGER { swFwEnvTemp(1), swFwEnvFan(2), swFwEnvPs(3), swFwTransceiverTemp(4), swFwTransceiverRxp(5), swFwTransceiverTxp(6), swFwTransceiverCurrent(7), swFwPortLink(8), swFwPortSync(9), swFwPortSignal(10), swFwPortPe(11), swFwPortWords(12), swFwPortCrcs(13), swFwPortRXPerf(14), swFwPortTXPerf(15), swFwPortState(16), swFwFabricEd(17), swFwFabricFr(18), swFwFabricDi(19), swFwFabricSc(20), swFwFabricZc(21), swFwFabricFq(22), swFwFabricFl(23), swFwFabricGs(24), swFwEPortLink(25), swFwEPortSync(26), swFwEPortSignal(27), swFwEPortPe(28), swFwEPortWords(29), swFwEPortCrcs(30), swFwEPortRXPerf(31), swFwEPortTXPerf(32), swFwEPortState(33), swFwFCUPortLink(34), swFwFCUPortSync(35), swFwFCUPortSignal(36), swFwFCUPortPe(37), swFwFCUPortWords(38), swFwFCUPortCrcs(39), swFwFCUPortRXPerf(40), swFwFCUPortTXPerf(41), swFwFCUPortState(42), swFwFOPPortLink(43), swFwFOPPortSync(44), swFwFOPPortSignal(45), swFwFOPPortPe(46), swFwFOPPortWords(47), swFwFOPPortCrcs(48), swFwFOPPortRXPerf(49), swFwFOPPortTXPerf(50), swFwFOPPortState(51), swFwPerfALPACRC(52), swFwPerfEToECRC(53), swFwPerfEToERxCnt(54), swFwPerfEToETxCnt(55), swFwPerffltCusDef(56), swFwTransceiverVoltage(57), swFwSecTelnetViolations(58), swFwSecHTTPViolations(59), swFwSecAPIViolations(60), swFwSecRSNMPViolations(61), swFwSecWSNMPViolations(62), swFwSecSESViolations(63), swFwSecMSViolations(64), swFwSecSerialViolations(65), swFwSecFPViolations(66), swFwSecSCCViolations(67), swFwSecDCCViolations(68), swFwSecLoginViolations(69), swFwSecInvalidTS(70), swFwSecInvalidSign(71), swFwSecInvalidCert(72), swFwSecSlapFail(73), swFwSecSlapBadPkt(74), swFwSecTSOutSync(75), swFwSecNoFcs(76), swFwSecIncompDB(77), swFwSecIllegalCmd(78), swFwSAMTotalDownTime(79), swFwSAMTotalUpTime(80), swFwSAMDurationOfOccur(81), swFwSAMFreqOfOccur(82), swFwResourceFlash(83), swFwEPortUtil(84), swFwEPortPktl(85), swFwPortLr(86), swFwEPortLr(87), swFwFCUPortLr(88), swFwFOPPortLr(89), swFwPortC3Discard(90), swFwEPortC3Discard(91), swFwFCUPortC3Discard(92), swFwFOPPortC3Discard(93), swFwVEPortStateChange(94), swFwVEPortUtil(95), swFwVEPortPktLoss(96), swFwEPortTrunkUtil(97), swFwFCUPortTrunkUtil(98), swFwFOPPortTrunkUtil(99), swFwCPUMemUsage(100) } -- write only variable for applying or canceling -- values or action matrix changes SwFwWriteVals ::= INTEGER { swFwCancelWrite(1), swFwApplyWrite(2) } -- timebase for thresholds SwFwTimebase ::= INTEGER { swFwTbNone(1), swFwTbSec(2), swFwTbMin(3), swFwTbHour(4), swFwTbDay(5) } -- status for thresholds SwFwStatus ::= INTEGER { disabled(1), enabled(2) } -- possible events available SwFwEvent ::= INTEGER { started(1), changed(2), exceeded(3), below(4), above(5), inBetween(6) } -- behavior type for thresholds SwFwBehavior ::= INTEGER { triggered(1), continuous(2) } -- state type for last events SwFwState ::= INTEGER { swFwInformative(1), swFwNormal(2), swFwFaulty(3) } -- license state SwFwLicense ::= INTEGER { swFwLicensed(1), swFwNotLicensed(2) } -- This is the first of the elements declared for Fabric Watch : -- one scalar & two tables -- A scalar, swFwFabricWatchLicense is used to tell is if the switch has -- proper license for Fabric Watch. Please refer to Fabric Watch -- documentation for further information. -- One table contains classArea information such as threshold unit string, -- time base, low thresholds, etc. The other table contains individual -- threshold information such as name, label, last event, etc. -- Please refer to Fabric Watch documentation for further information. -- license scalar swFwFabricWatchLicense OBJECT-TYPE SYNTAX SwFwLicense MAX-ACCESS read-only STATUS current DESCRIPTION "tells if licensed or not." ::= { swFwSystem 1 } -- classArea table swFwClassAreaTable OBJECT-TYPE SYNTAX SEQUENCE OF SwFwClassAreaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of classes and areas." ::= { swFwSystem 2 } swFwClassAreaEntry OBJECT-TYPE SYNTAX SwFwClassAreaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the classes and areas." INDEX { swFwClassAreaIndex } ::= { swFwClassAreaTable 1 } SwFwClassAreaEntry ::= SEQUENCE { swFwClassAreaIndex SwFwClassesAreas, swFwWriteThVals SwFwWriteVals, swFwDefaultUnit DisplayString, swFwDefaultTimebase SwFwTimebase, swFwDefaultLow Integer32, swFwDefaultHigh Integer32, swFwDefaultBufSize Integer32, swFwCustUnit DisplayString, swFwCustTimebase SwFwTimebase, swFwCustLow Integer32, swFwCustHigh Integer32, swFwCustBufSize Integer32, swFwThLevel SwFwLevels, swFwWriteActVals SwFwWriteVals, swFwDefaultChangedActs SwFwActs, swFwDefaultExceededActs SwFwActs, swFwDefaultBelowActs SwFwActs, swFwDefaultAboveActs SwFwActs, swFwDefaultInBetweenActs SwFwActs, swFwCustChangedActs SwFwActs, swFwCustExceededActs SwFwActs, swFwCustBelowActs SwFwActs, swFwCustAboveActs SwFwActs, swFwCustInBetweenActs SwFwActs, swFwValidActs SwFwActs, swFwActLevel SwFwLevels } swFwClassAreaIndex OBJECT-TYPE SYNTAX SwFwClassesAreas MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the class type." ::= { swFwClassAreaEntry 1 } -- this variable is used to apply or cancel -- changes made to swFwCustUnit, swFwCustTimebase, swFwCustLow, -- swFwCustHigh, swFwCustBufSize. -- read of this variable will always return cancel. swFwWriteThVals OBJECT-TYPE SYNTAX SwFwWriteVals MAX-ACCESS read-write STATUS current DESCRIPTION "This object is set to apply the value changes." ::= { swFwClassAreaEntry 2 } -- {swFwDefaultUnit, swFwDefaultTimebase, swFwDefaultMin, and swFwDefaultMax} -- {swFwCustUnit, swFwCustTimebase, swFwCustMin, and swFwCustMax} -- are grouped together to be applied to give threshold areas as in --- Default and Cust. Which of default, or custom groups applies depends --- on swFwThLevel. swFwDefaultUnit OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A Default unit string name for a threshold area." ::= { swFwClassAreaEntry 3 } swFwDefaultTimebase OBJECT-TYPE SYNTAX SwFwTimebase MAX-ACCESS read-only STATUS current DESCRIPTION "A Default timebase for the current threshold counter." ::= { swFwClassAreaEntry 4 } swFwDefaultLow OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "A Default low threshold value." ::= { swFwClassAreaEntry 5 } swFwDefaultHigh OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "A Default high threshold value." ::= { swFwClassAreaEntry 6 } swFwDefaultBufSize OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "A Default buffer size value." ::= { swFwClassAreaEntry 7 } swFwCustUnit OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A custom unit string name for a threshold area." ::= { swFwClassAreaEntry 8 } swFwCustTimebase OBJECT-TYPE SYNTAX SwFwTimebase MAX-ACCESS read-write STATUS current DESCRIPTION "A custom timebase for the current threshold counter." ::= { swFwClassAreaEntry 9 } swFwCustLow OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "A custom low threshold value." ::= { swFwClassAreaEntry 10 } swFwCustHigh OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "A custom high threshold value." ::= { swFwClassAreaEntry 11 } swFwCustBufSize OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "A custom buffer size value." ::= { swFwClassAreaEntry 12 } -- swFwThLevel is used to point to current level for classArea -- values. It is either default or custom. swFwThLevel OBJECT-TYPE SYNTAX SwFwLevels MAX-ACCESS read-write STATUS current DESCRIPTION "A level where all the threshold values are set at." ::= { swFwClassAreaEntry 13 } -- this variable is used to apply or cancel -- changes made to swFwCustUnit, swFwCustTimebase, swFwCustLow, -- swFwCustHigh, swFwCustBufSize. -- read of this variable will always return cancel. swFwWriteActVals OBJECT-TYPE SYNTAX SwFwWriteVals MAX-ACCESS read-write STATUS current DESCRIPTION "This object is set to apply act value changes." ::= { swFwClassAreaEntry 14 } -- {swFwDefaultChangedActs, swFwDefaultExceededActs, swFwDefaultBelowActs, -- and swFwDefaultAboveActs} and {swFwCustChangedActs, swFwCustExceededActs, -- swFwCustBelowActs, and swFwCustAboveActs} are grouped together to be -- applied to give threshold areas as in default and cust. Which of -- default, or custom groups applies depends on swFwThLevel. swFwDefaultChangedActs OBJECT-TYPE SYNTAX SwFwActs MAX-ACCESS read-only STATUS current DESCRIPTION "Default action matrix for changed event." ::= { swFwClassAreaEntry 15 } swFwDefaultExceededActs OBJECT-TYPE SYNTAX SwFwActs MAX-ACCESS read-only STATUS current DESCRIPTION "Default action matrix for exceeded event." ::= { swFwClassAreaEntry 16 } swFwDefaultBelowActs OBJECT-TYPE SYNTAX SwFwActs MAX-ACCESS read-only STATUS current DESCRIPTION "Default action matrix for below event." ::= { swFwClassAreaEntry 17 } swFwDefaultAboveActs OBJECT-TYPE SYNTAX SwFwActs MAX-ACCESS read-only STATUS current DESCRIPTION "Default action matrix for above event." ::= { swFwClassAreaEntry 18 } swFwDefaultInBetweenActs OBJECT-TYPE SYNTAX SwFwActs MAX-ACCESS read-only STATUS current DESCRIPTION "Default action matrix for in-between event." ::= { swFwClassAreaEntry 19 } swFwCustChangedActs OBJECT-TYPE SYNTAX SwFwActs MAX-ACCESS read-write STATUS current DESCRIPTION "custom action matrix for changed event." ::= { swFwClassAreaEntry 20 } swFwCustExceededActs OBJECT-TYPE SYNTAX SwFwActs MAX-ACCESS read-write STATUS current DESCRIPTION "custom action matrix for exceeded event." ::= { swFwClassAreaEntry 21 } swFwCustBelowActs OBJECT-TYPE SYNTAX SwFwActs MAX-ACCESS read-write STATUS current DESCRIPTION "custom action matrix for below event." ::= { swFwClassAreaEntry 22 } swFwCustAboveActs OBJECT-TYPE SYNTAX SwFwActs MAX-ACCESS read-write STATUS current DESCRIPTION "custom action matrix for above event." ::= { swFwClassAreaEntry 23 } swFwCustInBetweenActs OBJECT-TYPE SYNTAX SwFwActs MAX-ACCESS read-write STATUS current DESCRIPTION "custom action matrix for in-between event." ::= { swFwClassAreaEntry 24 } swFwValidActs OBJECT-TYPE SYNTAX SwFwActs MAX-ACCESS read-only STATUS current DESCRIPTION "matrix of valid acts for an class/area." ::= { swFwClassAreaEntry 25 } -- swFwActLevel is used to point to current level for classArea -- action matrix. It is either default or custom. swFwActLevel OBJECT-TYPE SYNTAX SwFwLevels MAX-ACCESS read-write STATUS current DESCRIPTION "A level where all the actions are set at." ::= { swFwClassAreaEntry 26 } -- table for individual threshold swFwThresholdTable OBJECT-TYPE SYNTAX SEQUENCE OF SwFwThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of individual thresholds." ::= { swFwSystem 3 } swFwThresholdEntry OBJECT-TYPE SYNTAX SwFwThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of an individual threshold." INDEX { swFwClassAreaIndex, swFwThresholdIndex } ::= { swFwThresholdTable 1 } SwFwThresholdEntry ::= SEQUENCE { swFwThresholdIndex Integer32, swFwStatus SwFwStatus, swFwName DisplayString, swFwLabel DisplayString, swFwCurVal Integer32, swFwLastEvent SwFwEvent, swFwLastEventVal Integer32, swFwLastEventTime DisplayString, swFwLastState SwFwState, swFwBehaviorType SwFwBehavior, swFwBehaviorInt Integer32, swFwLastSeverityLevel SwSevType } swFwThresholdIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the element index of an threshold." ::= { swFwThresholdEntry 1 } swFwStatus OBJECT-TYPE SYNTAX SwFwStatus MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies if an threshold is enabled or disabled." ::= { swFwThresholdEntry 2 } swFwName OBJECT-TYPE SYNTAX DisplayString(SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a name of the threshold." ::= { swFwThresholdEntry 3 } swFwLabel OBJECT-TYPE SYNTAX DisplayString(SIZE(0..70)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a label of the threshold." ::= { swFwThresholdEntry 4 } swFwCurVal OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a current counter of the threshold." ::= { swFwThresholdEntry 5 } swFwLastEvent OBJECT-TYPE SYNTAX SwFwEvent MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a last event type of the threshold." ::= { swFwThresholdEntry 6 } swFwLastEventVal OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a last event value of the threshold." ::= { swFwThresholdEntry 7 } swFwLastEventTime OBJECT-TYPE SYNTAX DisplayString(SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a last event time of the threshold." ::= { swFwThresholdEntry 8 } swFwLastState OBJECT-TYPE SYNTAX SwFwState MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a last event state of the threshold." ::= { swFwThresholdEntry 9 } swFwBehaviorType OBJECT-TYPE SYNTAX SwFwBehavior MAX-ACCESS read-write STATUS current DESCRIPTION "A behavior of which the thresholds generate event." ::= { swFwThresholdEntry 10 } swFwBehaviorInt OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "A integer of which the thresholds generate continuous event." ::= { swFwThresholdEntry 11 } swFwLastSeverityLevel OBJECT-TYPE SYNTAX SwSevType MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a last event severity level of the threshold." ::= { swFwThresholdEntry 12 } -- swEndDevice Group -- ########################################################################### -- table for RLS of end devices. -- swEndDevice consists of only one table. -- swEndDeviceRlsTable contains entries of individual end devices' rls. -- ########################################################################### swEndDeviceRlsTable OBJECT-TYPE SYNTAX SEQUENCE OF SwEndDeviceRlsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of individual end devices' rls." ::= { swEndDevice 1 } swEndDeviceRlsEntry OBJECT-TYPE SYNTAX SwEndDeviceRlsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of an individual end devices' rls." INDEX { swEndDevicePort, swEndDeviceAlpa } ::= { swEndDeviceRlsTable 1 } SwEndDeviceRlsEntry ::= SEQUENCE { swEndDevicePort Integer32, swEndDeviceAlpa Integer32, swEndDevicePortID OCTET STRING, swEndDeviceLinkFailure Counter32, swEndDeviceSyncLoss Counter32, swEndDeviceSigLoss Counter32, swEndDeviceProtoErr Counter32, swEndDeviceInvalidWord Counter32, swEndDeviceInvalidCRC Counter32 } -- Since Silkworm family switches start with port # 0 -- snmp port # should be physical port # + 1. -- i.e. snmp port # 3 translates to port # 2 swEndDevicePort OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object identifies the port of the end device." ::= { swEndDeviceRlsEntry 1 } -- snmp alpa # should be logical alpa # + 1. -- i.e. snmp alpa # 0xf0 translates to 0xef swEndDeviceAlpa OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object identifies the alpa of the end device." ::= { swEndDeviceRlsEntry 2 } swEndDevicePortID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The object identifies the Fibre Channel port address ID of the entry." ::= { swEndDeviceRlsEntry 3 } swEndDeviceLinkFailure OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Link failure count for the end device." ::= { swEndDeviceRlsEntry 4 } swEndDeviceSyncLoss OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Sync loss count for the end device." ::= { swEndDeviceRlsEntry 5 } swEndDeviceSigLoss OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Sig loss count for the end device." ::= { swEndDeviceRlsEntry 6 } swEndDeviceProtoErr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Protocol err count for the end device." ::= { swEndDeviceRlsEntry 7 } swEndDeviceInvalidWord OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Invalid word count for the end device." ::= { swEndDeviceRlsEntry 8 } swEndDeviceInvalidCRC OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Invalid CRC count for the end device." ::= { swEndDeviceRlsEntry 9 } -- table for displaying all the Groups swGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF SwGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of groups. This may not be available on all versions of Fabric OS." ::= { swGroup 1 } swGroupEntry OBJECT-TYPE SYNTAX SwGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of table of groups." INDEX { swGroupIndex } ::= { swGroupTable 1 } SwGroupEntry ::= SEQUENCE { swGroupIndex Integer32, swGroupName OCTET STRING, swGroupType OCTET STRING } swGroupIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object is the group index starting from 1." ::= { swGroupEntry 1 } swGroupName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the name of the group." ::= { swGroupEntry 2 } swGroupType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the type of the group." ::= { swGroupEntry 3 } -- table for displaying group members for all the groups swGroupMemTable OBJECT-TYPE SYNTAX SEQUENCE OF SwGroupMemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of members of all groups. This may not be available on all versions of Fabric OS." ::= { swGroup 2 } swGroupMemEntry OBJECT-TYPE SYNTAX SwGroupMemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry for a member of a group." INDEX { swGroupId, swGroupMemWwn } ::= { swGroupMemTable 1 } SwGroupMemEntry ::= SEQUENCE { swGroupId Integer32, swGroupMemWwn FcWwn, swGroupMemPos Integer32 } swGroupId OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the Group Id of the member switch." ::= { swGroupMemEntry 1 } swGroupMemWwn OBJECT-TYPE SYNTAX FcWwn MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the WWN of the member switch." ::= { swGroupMemEntry 2 } swGroupMemPos OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies position of the member switch in the group. This is based on the order that the switches were added in the group." ::= { swGroupMemEntry 3 } -- ************************************************************************************ -- Bloom Performance counter tables. * -- * -- ************************************************************************************ swBlmPerfALPAMntTable OBJECT-TYPE SYNTAX SEQUENCE OF SwBlmPerfALPAMntEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "ALPA monitoring counter Table. " ::= { swBlmPerfMnt 1} swBlmPerfALPAMntEntry OBJECT-TYPE SYNTAX SwBlmPerfALPAMntEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " ALPA monitoring counter for given ALPA." INDEX { swBlmPerfAlpaPort,swBlmPerfAlpaIndx } ::= { swBlmPerfALPAMntTable 1} SwBlmPerfALPAMntEntry ::= SEQUENCE { swBlmPerfAlpaPort SwPortIndex, swBlmPerfAlpaIndx Integer32, swBlmPerfAlpa Integer32, swBlmPerfAlpaCRCCnt OCTET STRING } swBlmPerfAlpaPort OBJECT-TYPE SYNTAX SwPortIndex MAX-ACCESS read-only STATUS current DESCRIPTION " This Object identifies the port index of the switch." ::= { swBlmPerfALPAMntEntry 1} swBlmPerfAlpaIndx OBJECT-TYPE SYNTAX Integer32 (1..126) MAX-ACCESS read-only STATUS current DESCRIPTION " This Object identifies the ALPA index. There can be 126 ALPA values" ::= { swBlmPerfALPAMntEntry 2} swBlmPerfAlpa OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION " This Object identifies the ALPA values. These values range between x'01' and x'EF'(1 to 239). ALPA value x'00' is reserved for FL_Port If Alpa device is invalid, then it will have -1 value. " ::= { swBlmPerfALPAMntEntry 3} swBlmPerfAlpaCRCCnt OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "Get CRC count for given ALPA and port. This monitoring provides information on the number of CRC errors occurred on the frames destined to each possible ALPA attached to a specific port." ::= { swBlmPerfALPAMntEntry 4} swBlmPerfEEMntTable OBJECT-TYPE SYNTAX SEQUENCE OF SwBlmPerfEEMntEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " End-to-End monitoring counter Table" ::= { swBlmPerfMnt 2} swBlmPerfEEMntEntry OBJECT-TYPE SYNTAX SwBlmPerfEEMntEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "End-to-End monitoring counter for given port." INDEX { swBlmPerfEEPort, swBlmPerfEERefKey} ::= { swBlmPerfEEMntTable 1} SwBlmPerfEEMntEntry ::= SEQUENCE{ swBlmPerfEEPort SwPortIndex, swBlmPerfEERefKey Integer32, swBlmPerfEECRC OCTET STRING, swBlmPerfEEFCWRx OCTET STRING, swBlmPerfEEFCWTx OCTET STRING, swBlmPerfEESid Integer32, swBlmPerfEEDid Integer32 } swBlmPerfEEPort OBJECT-TYPE SYNTAX SwPortIndex MAX-ACCESS read-only STATUS current DESCRIPTION " This object identifies the port number of the switch." ::= { swBlmPerfEEMntEntry 1} swBlmPerfEERefKey OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the reference number of the counter. This reference is number assigned when a filter is created. In SNMP Index start one instead of 0, add one to actual ref key" ::= { swBlmPerfEEMntEntry 2} swBlmPerfEECRC OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION " Get End to End CRC error for the frames that matched the SID-DID pair." ::= { swBlmPerfEEMntEntry 3} swBlmPerfEEFCWRx OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "Get End to End count of Fibre Channel words (FCW), received by the port, that matched the SID-DID pair. " ::= { swBlmPerfEEMntEntry 4 } swBlmPerfEEFCWTx OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "Get End to End count of Fibre Channel words (FCW), transmitted by the port, that matched the SID-DID pair. " ::= { swBlmPerfEEMntEntry 5} swBlmPerfEESid OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION " Gets SID info by reference number. SID (Source Identifier) is a 3-byte field in the frame header used to indicate the address identifier of the N-Port from which the frame was sent." ::= { swBlmPerfEEMntEntry 6 } swBlmPerfEEDid OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Gets DID info by reference number. DID (Destination Identifier) is a 3-byte field in the frame header used to indicate the address identifier of the N-Port to which the frame was sent." ::= { swBlmPerfEEMntEntry 7 } swBlmPerfFltMntTable OBJECT-TYPE SYNTAX SEQUENCE OF SwBlmPerfFltMntEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Filter based monitoring counter." ::= { swBlmPerfMnt 3} swBlmPerfFltMntEntry OBJECT-TYPE SYNTAX SwBlmPerfFltMntEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Filter base monitoring counter for given port." INDEX { swBlmPerfFltPort,swBlmPerfFltRefkey} ::= { swBlmPerfFltMntTable 1} SwBlmPerfFltMntEntry ::= SEQUENCE{ swBlmPerfFltPort SwPortIndex, swBlmPerfFltRefkey Integer32, swBlmPerfFltCnt OCTET STRING, swBlmPerfFltAlias DisplayString } swBlmPerfFltPort OBJECT-TYPE SYNTAX SwPortIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the port number of the switch." ::= { swBlmPerfFltMntEntry 1} swBlmPerfFltRefkey OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION " This object identifies the reference number of the filter. This reference number is assigned when a filter is created. In SNMP Index start one instead of 0, add one to actual ref key" ::= { swBlmPerfFltMntEntry 2} swBlmPerfFltCnt OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "Get statistics of filter based monitor. Filter based monitoring provides information about a filter hit count such as 1. Read command 2. SCSI or IP traffic 3. SCSI Read/Write" ::= { swBlmPerfFltMntEntry 3 } swBlmPerfFltAlias OBJECT-TYPE SYNTAX DisplayString(SIZE(0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION " Alias name for the filter." ::= { swBlmPerfFltMntEntry 4} swSwitchTrunkable OBJECT-TYPE SYNTAX INTEGER { yes ( 8 ) , no ( 0 ) } MAX-ACCESS read-only STATUS current DESCRIPTION "The trunking status of the switch - whether the switch supports the trunking feature or not. The values are yes(8) - the trunking feature is supported no(0). - the trunking feature is not supported. " ::= { swTrunk 1} swTrunkTable OBJECT-TYPE SYNTAX SEQUENCE OF SwTrunkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Table to display trunking information for the switch. " ::= { swTrunk 2} swTrunkEntry OBJECT-TYPE SYNTAX SwTrunkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for the trunking table." INDEX { swTrunkPortIndex } ::= { swTrunkTable 1} SwTrunkEntry ::= SEQUENCE{ swTrunkPortIndex SwPortIndex, swTrunkGroupNumber Integer32, swTrunkMaster SwTrunkMaster, swPortTrunked INTEGER } swTrunkPortIndex OBJECT-TYPE SYNTAX SwPortIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the switch port index. Note that the value of a port index is 1 higher than the port number labeled on the front panel. e.g. port index 1 correspond to port number 0. " ::= { swTrunkEntry 1 } swTrunkGroupNumber OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a logical entity which specifies the Group Number to which the port belongs to. If this value is Zero it means the port is not Trunked." ::= { swTrunkEntry 2} swTrunkMaster OBJECT-TYPE SYNTAX SwTrunkMaster MAX-ACCESS read-only STATUS current DESCRIPTION "Port number that is the trunk master of the group. The trunk master implicitly defines the group. All ports with the same master are considered to be part of the same group." ::= { swTrunkEntry 3 } swPortTrunked OBJECT-TYPE SYNTAX INTEGER {disabled(0), enabled(1)} MAX-ACCESS read-only STATUS current DESCRIPTION "The active trunk status for a member port. Values are enabled(1) or disabled(0)." ::= { swTrunkEntry 4 } swTrunkGrpTable OBJECT-TYPE SYNTAX SEQUENCE OF SwTrunkGrpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table to display trunking Performance information for the switch." ::= { swTrunk 3} swTrunkGrpEntry OBJECT-TYPE SYNTAX SwTrunkGrpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for the trunking Group table." INDEX { swTrunkGrpNumber} ::= { swTrunkGrpTable 1} SwTrunkGrpEntry ::= SEQUENCE{ swTrunkGrpNumber Integer32, swTrunkGrpMaster SwTrunkMaster, swTrunkGrpTx OCTET STRING, swTrunkGrpRx OCTET STRING } swTrunkGrpNumber OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a logical entity which specifies the Group Number to which port belongs to." ::= { swTrunkGrpEntry 1 } swTrunkGrpMaster OBJECT-TYPE SYNTAX SwTrunkMaster MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the master port id for the TrunkGroup." ::= { swTrunkGrpEntry 2 } swTrunkGrpTx OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "Gives the aggregate value of the transmitted words from this TrunkGroup." ::= { swTrunkGrpEntry 3} swTrunkGrpRx OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "Gives the aggregate value of the received words by this TrunkGroup." ::= { swTrunkGrpEntry 4 } swTopTalkerMntMode OBJECT-TYPE SYNTAX INTEGER { fabricmode (1), fportmode (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Gives the mode in which toptalker is installed" ::= { swTopTalker 1} swTopTalkerMntNumEntries OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Gives the number of toptalking flows" ::= { swTopTalker 2} swTopTalkerMntTable OBJECT-TYPE SYNTAX SEQUENCE OF SwTopTalkerMntEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table to display toptalkingflows" ::= { swTopTalker 3} swTopTalkerMntEntry OBJECT-TYPE SYNTAX SwTopTalkerMntEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for the toptalker table" INDEX{ swTopTalkerMntIndex} ::= { swTopTalkerMntTable 1} SwTopTalkerMntEntry ::= SEQUENCE{ swTopTalkerMntIndex Integer32, swTopTalkerMntPort Integer32, swTopTalkerMntSpid Integer32, swTopTalkerMntDpid Integer32, swTopTalkerMntflow Integer32, swTopTalkerMntSwwn FcWwn, swTopTalkerMntDwwn FcWwn } swTopTalkerMntIndex OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the list/object entry" ::= { swTopTalkerMntEntry 1} swTopTalkerMntPort OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the switch port number on which the f-port mode toptalker is added." ::= { swTopTalkerMntEntry 2} swTopTalkerMntSpid OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the SID of the host" ::= { swTopTalkerMntEntry 3} swTopTalkerMntDpid OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the DID of the SID-DID pair" ::= { swTopTalkerMntEntry 4} swTopTalkerMntflow OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the traffic flow in MB/sec" ::= { swTopTalkerMntEntry 5} swTopTalkerMntSwwn OBJECT-TYPE SYNTAX FcWwn MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the SID in WWN format of the host" ::= { swTopTalkerMntEntry 6} swTopTalkerMntDwwn OBJECT-TYPE SYNTAX FcWwn MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the DID in WWN format of the SID-DID pair" ::= { swTopTalkerMntEntry 7} swCpuUsage OBJECT-TYPE SYNTAX Integer32(0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "System's cpu usage." ::= { swCpuOrMemoryUsage 1 } swCpuNoOfRetries OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of times system should take cpu utilization sample before sending the CPU utilization trap." ::= { swCpuOrMemoryUsage 2 } swCpuUsageLimit OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "CPU usage limit" ::= { swCpuOrMemoryUsage 3 } swCpuPollingInterval OBJECT-TYPE SYNTAX Integer32 (10..3600) UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Time interval between two memory samples." ::= { swCpuOrMemoryUsage 4 } swCpuAction OBJECT-TYPE SYNTAX Integer32 (0..3) UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the actions to be taken if system resources exceed the specified threshold." ::= { swCpuOrMemoryUsage 5 } swMemUsage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "System's memory usage." ::= { swCpuOrMemoryUsage 6 } swMemNoOfRetries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of times system should take memory usage sample before sending the memory usage trap." ::= { swCpuOrMemoryUsage 7 } swMemUsageLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Memory usage limit" ::= { swCpuOrMemoryUsage 8 } swMemPollingInterval OBJECT-TYPE SYNTAX Integer32 (10..3600) UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Time interval between two memory samples." ::= { swCpuOrMemoryUsage 9 } swMemAction OBJECT-TYPE SYNTAX Integer32 (0..3) UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the actions to be taken if system resources exceed the specified threshold." ::= { swCpuOrMemoryUsage 10 } swMemUsageLimit1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Low memory usage limit" ::= { swCpuOrMemoryUsage 11 } swMemUsageLimit3 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "High memory usage limit" ::= { swCpuOrMemoryUsage 12 } swConnUnitPortStatEntry OBJECT-TYPE SYNTAX SwConnUnitPortStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This represents the Conn unit Port Stats" AUGMENTS {connUnitPortStatEntry} ::= { swConnUnitPortStatExtentionTable 1 } SwConnUnitPortStatEntry ::= SEQUENCE { swConnUnitCRCWithBadEOF OCTET STRING, swConnUnitZeroTenancy OCTET STRING, swConnUnitFLNumOfTenancy OCTET STRING, swConnUnitNLNumOfTenancy OCTET STRING, swConnUnitStopTenancyStarVation OCTET STRING, swConnUnitOpend OCTET STRING, swConnUnitTransferConnection OCTET STRING, swConnUnitOpen OCTET STRING, swConnUnitInvalidARB OCTET STRING, swConnUnitFTB1Miss OCTET STRING, swConnUnitFTB2Miss OCTET STRING, swConnUnitFTB6Miss OCTET STRING, swConnUnitZoneMiss OCTET STRING, swConnUnitLunZoneMiss OCTET STRING, swConnUnitBadEOF OCTET STRING, swConnUnitLCRX OCTET STRING, swConnUnitRDYPriority OCTET STRING, swConnUnitLli OCTET STRING } swConnUnitCRCWithBadEOF OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames with CRC error with Bad EOF." ::= { swConnUnitPortStatEntry 1 } swConnUnitZeroTenancy OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when the FL_port acquires the loop but does not transmit a frame." ::= { swConnUnitPortStatEntry 2 } swConnUnitFLNumOfTenancy OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when the FL_port acquires the loop." ::= { swConnUnitPortStatEntry 3 } swConnUnitNLNumOfTenancy OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when the NL_port acquires the loop." ::= { swConnUnitPortStatEntry 4 } swConnUnitStopTenancyStarVation OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when the FL_port can not transmit a frame because of lack of credit." ::= { swConnUnitPortStatEntry 5 } swConnUnitOpend OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times FC port entered OPENED state." ::= { swConnUnitPortStatEntry 6 } swConnUnitTransferConnection OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times FC port entered TRANSFER state." ::= { swConnUnitPortStatEntry 7 } swConnUnitOpen OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times FC port entered OPEN state." ::= { swConnUnitPortStatEntry 8 } swConnUnitInvalidARB OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times FC port received invalid ARB." ::= { swConnUnitPortStatEntry 9 } swConnUnitFTB1Miss OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when the port receives a frame with a DID that can not be routed by FCR.. Applicable to 8G platforms only." ::= { swConnUnitPortStatEntry 10 } swConnUnitFTB2Miss OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when the port receives a frame with an SID/DID combination that can not be routed by the VF module.Applicable to 8G platforms only." ::= { swConnUnitPortStatEntry 11 } swConnUnitFTB6Miss OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when port receives a frame with an SID that can not be routed by FCR. Applicable to 8G platforms." ::= { swConnUnitPortStatEntry 12 } swConnUnitZoneMiss OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when the port receives a frame with an SID and DID that are not zoned together." ::= { swConnUnitPortStatEntry 13 } swConnUnitLunZoneMiss OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when the port receives a frame with an SID, DID and LUN that are not zoned together( This is not currently used )." ::= { swConnUnitPortStatEntry 14 } swConnUnitBadEOF OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames with bad end-of-frame." ::= { swConnUnitPortStatEntry 15 } swConnUnitLCRX OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of link control frames received." ::= { swConnUnitPortStatEntry 16 } swConnUnitRDYPriority OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that sending R_RDY or VC_RDY primitive signals was a higher priority than sending frames, due to diminishing credit reserves in the transmitter at the other end of the fibre." ::= { swConnUnitPortStatEntry 17 } swConnUnitLli OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The number low level interrupts generated by the physical and link layer." ::= { swConnUnitPortStatEntry 18 } -- -- Enterprise Specific Traps for Fibre Channel Switch (sw). -- swTrapsV2 OBJECT-IDENTITY STATUS current DESCRIPTION "The Traps for Brocade's Fibre Channel Switch." ::= { sw 0 } swFault NOTIFICATION-TYPE OBJECTS { swDiagResult, swSsn , swGroupName, swGroupType, swGroupMemPos } STATUS obsolete DESCRIPTION "Obsoleted this trap as firmware doesn't support this trap. A swFault(1) is generated whenever the diagnostics detects a fault with the switch." --#TYPE "Switch is faulty." --#SUMMARY "Faulty reason: %d and SSN is #%s,GroupName %s,GroupType %s,GroupMemPosition %d"" --#ARGUMENTS { 0, 1, 2, 3, 4} --#SEVERITY CRITICAL --#TIMEINDEX 1 --#STATE NONOPERATIONAL ::= { swTrapsV2 1 } swSensorScn NOTIFICATION-TYPE OBJECTS { swSensorStatus, swSensorIndex, swSensorType, swSensorValue, swSensorInfo, swSsn, swGroupName, swGroupType, swGroupMemPos } STATUS current DESCRIPTION "A swSensorScn(2) is generated whenever an environment sensor changes its operational state. For instance, a fan stop working. The VarBind in the Trap Data Unit shall contain the corresponding instance of the sensor status, sensor index, sensor type, sensor value (reading) and sensor information. Note that the sensor information contains the type of sensor and its number in textual format." --#TYPE "A sensor (temperature, fan, etc.) changed its operational state." --#SUMMARY "%s: is currently in state %d and SSN is #%s" --#ARGUMENTS { 4, 0, 5 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#STATE OPERATIONAL ::= { swTrapsV2 2 } swFCPortScn NOTIFICATION-TYPE OBJECTS { swFCPortOpStatus, swFCPortIndex, swFCPortName, swSsn, swFCPortFlag, swGroupName, swGroupType, swGroupMemPos, swVfId } STATUS current DESCRIPTION "A swFCPortScn(3) is generated whenever an FC_Port changes its operational state. For instance, the FC_Port goes from on-line to offline. The VarBind in the Trap Data Unit shall contain the corresponding instance of the FC_Port's operational status, index, swFCPortName,swSsn and swFCPortFlag. swSsn is optional varbind sent when swExtTrap is also enabled.swVfId is optional if VF is enabled. The three arguments swGroupName, swGroupType, swGroupMemPos belong to swGroup table which is obsolete and not implemented." --#TYPE "A Fibre Channel Port changed its operational state." --#SUMMARY "Port Index %d changed state to %d Port Name: %s and SSN is #%s" --#ARGUMENTS { 1, 0, 2, 3 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#STATE OPERATIONAL ::= { swTrapsV2 3 } swEventTrap NOTIFICATION-TYPE OBJECTS { swEventIndex, swEventTimeInfo, swEventLevel, swEventRepeatCount, swEventDescr, swSsn, swGroupName,swGroupType,swGroupMemPos,swVfId } STATUS current DESCRIPTION "This trap is generated when an event whose level at or below swEventTrapLevel occurs." --#TYPE "A firmware event has been logged" --#SUMMARY "Event %d: %s (severity level %d) - %s SSN is #%s" --#ARGUMENTS { 0, 1, 2, 4, 5 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#STATE OPERATIONAL ::= { swTrapsV2 4 } -- traps for Fabric Watch subsystem swFabricWatchTrap NOTIFICATION-TYPE OBJECTS { swFwClassAreaIndex, swFwThresholdIndex, swFwName, swFwLabel, swFwLastEventVal, swFwLastEventTime, swFwLastEvent, swFwLastState, swFwLastSeverityLevel, swSsn, swGroupName, swGroupType, swGroupMemPos, swVfId } STATUS current DESCRIPTION "trap to be sent by Fabric Watch to notify of an event" --#TYPE "Fabric Watch has generated an event" --#SUMMARY "Threshold %s in Class/Area %d at index %d has generated event %d with %d on %s. This event is %d. This event label is %d, event severity level is %d and SSN is #%s" --#ARGUMENTS { 2, 0, 1, 6, 4, 5, 7, 3, 8, 9 } --#SEVERITY WARNING --#TIMEINDEX 1 --#STATE OPERATIONAL ::= { swTrapsV2 5 } -- traps for track changes subsystem swTrackChangesTrap NOTIFICATION-TYPE OBJECTS { swTrackChangesInfo, swSsn, swGroupName, swGroupType, swGroupMemPos, swVfId } STATUS current DESCRIPTION "trap to be sent for tracking login/logout/config changes" --#TYPE "Track changes has generated a trap" --#SUMMARY "%s and SSN is #%s" --#ARGUMENTS { 0, 1 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#STATE OPERATIONAL ::= { swTrapsV2 6 } swIPv6ChangeTrap NOTIFICATION-TYPE OBJECTS { swIPv6Address, swIPv6Status } STATUS current DESCRIPTION "This trap is generated when an ipv6 address status change event occurs." --#TYPE "IPv6 address status change has generated a trap" --#SUMMARY --#ARGUMENTS --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#STATE OPERATIONAL ::= { swTrapsV2 7 } swPmgrEventTrap NOTIFICATION-TYPE OBJECTS { swPmgrEventType, swPmgrEventTime, swPmgrEventDescr, swSsn, swVfId } STATUS current DESCRIPTION "This trap is generated when any partition manager change happens." --#TYPE "Partition manager status change has generated a trap" --#SUMMARY "pmgr event of type %d occured on %d swVfId and SSN is #%s. Time is %s and the description is %s" --#ARGUMENTS { 0, 4, 3, 1, 2 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#STATE OPERATIONAL ::= { swTrapsV2 8 } swFabricReconfigTrap NOTIFICATION-TYPE OBJECTS { swDomainID } STATUS current DESCRIPTION "trap to be sent for tracking fabric reconfiguration" --#TYPE "Fabric reconfiguration has generated a trap" --#SUMMARY --#ARGUMENTS --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#STATE OPERATIONAL ::= { swTrapsV2 9 } swFabricSegmentTrap NOTIFICATION-TYPE OBJECTS { swFCPortIndex, swFCPortName, swSsn, swFCPortFlag, swVfId } STATUS current DESCRIPTION "trap to be sent for tracking segmentation" --#TYPE "Fabric segmentation has generated a trap" --#SUMMARY --#ARGUMENTS --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#STATE OPERATIONAL ::= { swTrapsV2 10 } swExtTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "THIS IS INTERNAL TRAP" ::= { swTrapsV2 11 } -- end of Enterprise Specific Traps for Fibre Channel Switch (sw) END