OCCAM-MLT-MIB DEFINITIONS ::= BEGIN IMPORTS occamGenericMonitorModules FROM OCCAM-REG-MODULE TEXTUAL-CONVENTION FROM SNMPv2-TC MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY, Integer32, NOTIFICATION-TYPE FROM SNMPv2-SMI; occamMltMib MODULE-IDENTITY LAST-UPDATED "200104271051Z" ORGANIZATION "Occam Networks" CONTACT-INFO "email support@occamnetworks.com" DESCRIPTION "This mib module describes objects used to perform Metallic Line Testing on customer access lines and to provide results." REVISION "200104271051Z" DESCRIPTION "Reformatted certain text" REVISION "200704170000Z" DESCRIPTION "replace kOhm with Ohm in DC resistance UNITS" REVISION "200702220000Z" DESCRIPTION "remove DISPLAY-HINT" REVISION "200609261000Z" DESCRIPTION "Removed Gr909 from fuse test result names" REVISION "200602220135Z" DESCRIPTION "Initial version." ::= { occamGenericMonitorModules 3 } -- TEXTUAL-CONVENTIONS -- MltTestType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A selection value for requesting or forcing a test. A requested test will only run if the port is not in use. A forced test will immediately shut the port and run the test." SYNTAX INTEGER { request ( 1 ) , force ( 2 ) } MltTestStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An indication of test status: none = no test has been requested. mltbusy = another port is currently being tested. complete = the last requested test has completed. portInUse = the last requested port is in use, the test was not run. Rerunning the test as 'forced' will shut the port and run the test. inProgress = the last requested test is still running. mltError = the mlt program reported an error and aborted the test.Check the mltErrorText object. mltNotResponding = the mlt program didn't return a result." SYNTAX INTEGER { none ( 1 ) , mltBusy ( 2 ), complete ( 3 ) , portInUse ( 4 ) , inProgress ( 5 ), mltError ( 6 ), mltNotResponding ( 7 ) } MltTestIdentifier ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An mlt test selection value." SYNTAX INTEGER { statusSuite ( 1 ) , mltSuite ( 2 ) , activeModeVoltages ( 3 ) , highImpedanceModeVoltages ( 4 ) , dcResistance ( 5 ) , capacitance ( 6 ) , loopDetect ( 7 ) , loopLength ( 8 ) } MltTestHookState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An mlt test hook state value." SYNTAX INTEGER { onhook ( 1 ) , offhook ( 2 ), notAvailable ( 3 ) } MltTestPassFail ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An mlt test pass/fail value." SYNTAX INTEGER { pass ( 1 ) , fail ( 2 ), notAvailable ( 3 ) } MltTestRingerResult ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An mlt ringer test result value." SYNTAX INTEGER { pass ( 1 ) , fail ( 2 ), notAvailable ( 3 ), low ( 4 ) } MltTestYesNo ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An mlt test pass/fail value." SYNTAX INTEGER { yes ( 1 ) , no ( 2 ), notAvailable ( 3 ) } -- The Metallic Loop Test Configuration group mltTestConfig OBJECT IDENTIFIER ::= { occamMltMib 1 } -- The Metallic Loop Test Status group mltTestStatus OBJECT IDENTIFIER ::= { occamMltMib 2 } -- The Metallic Loop Test Results group mltTestResults OBJECT IDENTIFIER ::= { occamMltMib 3 } -- The Metallic Loop Test Notifications group mltTestNotifications OBJECT IDENTIFIER ::= { occamMltMib 4 } -- Objects of the MLT Configuration group mltTestIdentifier OBJECT-TYPE SYNTAX MltTestIdentifier MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the mlt test to be run. Setting this value starts a test. This is a required parameter. Approximate expected test durations are as follows: statusSuite 1 second mltSuite 1 minute activeModeVoltages 3 seconds highImpedanceModeVoltages 9 seconds dcResistance 18 seconds capacitance 18 seconds loopDetect 9 seconds loopLength 9 seconds." ::= { mltTestConfig 1 } mltTestType OBJECT-TYPE SYNTAX MltTestType MAX-ACCESS read-write STATUS current DESCRIPTION "Selects if a test is requested (only run if port is not in use) or forced. This is an optional parameter. If not specified, the request option is used." ::= { mltTestConfig 2 } mltTestPort OBJECT-TYPE SYNTAX Integer32 ( 1 .. 48 ) MAX-ACCESS read-write STATUS current DESCRIPTION "Selects voice channel on which test will be run. This is a required parameter." ::= { mltTestConfig 3 } mltDcResistanceRange OBJECT-TYPE SYNTAX Integer32 ( 0 .. 3 ) MAX-ACCESS read-write STATUS current DESCRIPTION "Selects DC Resistance range value. This is an optional paramater. Default is 0 (auto mode)." ::= { mltTestConfig 4 } mltLoopLengthMultiplier OBJECT-TYPE SYNTAX Integer32 ( 10 .. 200 ) MAX-ACCESS read-write STATUS current DESCRIPTION "Selects loop length multiplier in nf. This is an optional parameter. If not specified an internal default value of 83nF/mile is used." ::= { mltTestConfig 5 } mltLoopDetectThreshold OBJECT-TYPE SYNTAX Integer32 ( 5 .. 200 ) MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the detection threshold in nF. This is an optional parameter. If not supplied, a loop detection threshold of 10nF is used." ::= { mltTestConfig 6 } -- Objects of the MLT Test Status group mltLastTestStatus OBJECT-TYPE SYNTAX MltTestStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the status of the last run mlt test. Given that the various mlt tests take several seconds to 1 1/2 minutes to run, it is suggested that status polls be spaced 10-20 seconds apart. Additionally, a monitoring application could wait for the testComplete notification." ::= { mltTestStatus 1 } mltErrorText OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the textual error in the case of an aborted test." ::= { mltTestStatus 2 } -- Objects of the MLT Test Results group -- mlt status results table mltStatusResultsTable OBJECT-TYPE SYNTAX SEQUENCE OF MltStatusResultsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides result of the status test suite." ::= { mltTestResults 1 } mltStatusResultsEntry OBJECT-TYPE SYNTAX MltStatusResultsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry holding information about results of status suite tests. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured." INDEX { mltTestPort } ::= { mltStatusResultsTable 1 } MltStatusResultsEntry ::= SEQUENCE { mltStatusAlarm OCTET STRING, mltStatusHookState MltTestHookState, mltStatusTransversalCurrent Integer32, mltStatusLongitudinalCurrent Integer32, mltStatusTipVoltage Integer32, mltStatusRingVoltage Integer32, mltStatusTipRingVoltage Integer32, mltStatusVdd Integer32 } mltStatusAlarm OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates GNK and/or OTEMP alarms active when status test was run." ::= { mltStatusResultsEntry 1 } mltStatusHookState OBJECT-TYPE SYNTAX MltTestHookState MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates line hook state when status test was run." ::= { mltStatusResultsEntry 2 } mltStatusTransversalCurrent OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 mA" MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates transversal current when status test was run." ::= { mltStatusResultsEntry 3 } mltStatusLongitudinalCurrent OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 mA" MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates Longitudinal current when status test was run." ::= { mltStatusResultsEntry 4 } mltStatusTipVoltage OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 V" MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates tip voltage when status test was run." ::= { mltStatusResultsEntry 5 } mltStatusRingVoltage OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 V" MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates ring voltage when status test was run." ::= { mltStatusResultsEntry 6 } mltStatusTipRingVoltage OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 V" MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates tip-ring voltage when status test was run." ::= { mltStatusResultsEntry 7 } mltStatusVdd OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 V" MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates Vdd when status test was run." ::= { mltStatusResultsEntry 8 } -- mlt test results table mltTestResultsTable OBJECT-TYPE SYNTAX SEQUENCE OF MltTestResultsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. Also, a resistance value of 9999 means that the result was greater than 1000 kOhms, but the exact value could not be measured." ::= { mltTestResults 2 } mltTestResultsEntry OBJECT-TYPE SYNTAX MltTestResultsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry holding information about results of mlt suite tests." INDEX { mltTestPort } ::= { mltTestResultsTable 1 } MltTestResultsEntry ::= SEQUENCE { mltTestAlarm OCTET STRING, mltTestHookState MltTestHookState, mltTestVdd Integer32, mltTestActiveModeVoltagesVdctr Integer32, mltTestActiveModeVoltagesVdctg Integer32, mltTestActiveModeVoltagesVdcrg Integer32, mltTestActiveModeVoltagesVactr Integer32, mltTestActiveModeVoltagesVactg Integer32, mltTestActiveModeVoltagesVacrg Integer32, mltTestHighImpedanceModeVoltagesVdctr Integer32, mltTestHighImpedanceModeVoltagesVdctg Integer32, mltTestHighImpedanceModeVoltagesVdcrg Integer32, mltTestHighImpedanceModeVoltagesVactr Integer32, mltTestHighImpedanceModeVoltagesVactg Integer32, mltTestHighImpedanceModeVoltagesVacrg Integer32, mltTestDcCurrentsItransversal Integer32, mltTestDcCurrentsIlongitudinal Integer32, mltTestDcCurrentsItip Integer32, mltTestDcCurrentsIring Integer32, mltTestCapacitanceCeqtr Integer32, mltTestCapacitanceCeqtg Integer32, mltTestCapacitanceCeqrg Integer32, mltTestResistanceRtr Integer32, mltTestResistanceRtg Integer32, mltTestResistanceRrg Integer32, mltTestGr909HazardousPotentialTestResult MltTestPassFail, mltTestGr909ForeignEmfTestResult MltTestPassFail, mltTestGr909FuseTestTipFuse MltTestPassFail, mltTestGr909FuseTestRingFuse MltTestPassFail, mltTestFuseTestTipFuse MltTestPassFail, mltTestFuseTestRingFuse MltTestPassFail, mltTestGr909ResistiveFaultTestResult MltTestPassFail, mltTestGr909ReceiverOffhookTestResult MltTestPassFail, mltTestGr909ReceiverOffhookTestResistance1 Integer32, mltTestGr909ReceiverOffhookTestResistance2 Integer32, mltTestGr909ReceiverOffhookTestDifference Integer32, mltTestGr909RingerTestResult MltTestRingerResult, mltTestGr909RingerTestRen Integer32, mltTestErrors OCTET STRING } mltTestAlarm OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "GNK and OTEMP bits set by the DuSLIC will be reported as alarms. GNK is typically cause by ground fault or foreign voltage condition. OTEMP is set when the DuSLIC is experiencing thermal overload. This parameter is non-intrusive." ::= { mltTestResultsEntry 1 } mltTestHookState OBJECT-TYPE SYNTAX MltTestHookState MAX-ACCESS read-only STATUS current DESCRIPTION "Hook state reflects the DuSLIC hook bit (offhook/onhook). This parameter is non-intrusive." ::= { mltTestResultsEntry 2 } mltTestVdd OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 V" MAX-ACCESS read-only STATUS current DESCRIPTION "On HDPOTS, internal Voltage VDD will be reported and compared to statistically derived thresholds. This parameter is intrusive during offhook but will be available during onhook." ::= { mltTestResultsEntry 3 } mltTestActiveModeVoltagesVdctr OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vdc" MAX-ACCESS read-only STATUS current DESCRIPTION "Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 4 } mltTestActiveModeVoltagesVdctg OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vdc" MAX-ACCESS read-only STATUS current DESCRIPTION "Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 5 } mltTestActiveModeVoltagesVdcrg OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vdc" MAX-ACCESS read-only STATUS current DESCRIPTION "Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 6 } mltTestActiveModeVoltagesVactr OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vrms" MAX-ACCESS read-only STATUS current DESCRIPTION "Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 7 } mltTestActiveModeVoltagesVactg OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vrms" MAX-ACCESS read-only STATUS current DESCRIPTION "Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 8 } mltTestActiveModeVoltagesVacrg OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vrms" MAX-ACCESS read-only STATUS current DESCRIPTION "Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 9 } mltTestHighImpedanceModeVoltagesVdctr OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vdc" MAX-ACCESS read-only STATUS current DESCRIPTION "High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 10 } mltTestHighImpedanceModeVoltagesVdctg OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vdc" MAX-ACCESS read-only STATUS current DESCRIPTION "High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 11 } mltTestHighImpedanceModeVoltagesVdcrg OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vdc" MAX-ACCESS read-only STATUS current DESCRIPTION "High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 12 } mltTestHighImpedanceModeVoltagesVactr OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vrms" MAX-ACCESS read-only STATUS current DESCRIPTION "High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 13 } mltTestHighImpedanceModeVoltagesVactg OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vrms" MAX-ACCESS read-only STATUS current DESCRIPTION "High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 14 } mltTestHighImpedanceModeVoltagesVacrg OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vrms" MAX-ACCESS read-only STATUS current DESCRIPTION "High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 15 } mltTestDcCurrentsItransversal OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 mA" MAX-ACCESS read-only STATUS current DESCRIPTION "Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present." ::= { mltTestResultsEntry 16 } mltTestDcCurrentsIlongitudinal OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 mA" MAX-ACCESS read-only STATUS current DESCRIPTION "Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present." ::= { mltTestResultsEntry 17 } mltTestDcCurrentsItip OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 mA" MAX-ACCESS read-only STATUS current DESCRIPTION "Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present." ::= { mltTestResultsEntry 18 } mltTestDcCurrentsIring OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 mA" MAX-ACCESS read-only STATUS current DESCRIPTION "Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present." ::= { mltTestResultsEntry 19 } mltTestCapacitanceCeqtr OBJECT-TYPE SYNTAX Integer32 UNITS "nF" MAX-ACCESS read-only STATUS current DESCRIPTION "Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 20 } mltTestCapacitanceCeqtg OBJECT-TYPE SYNTAX Integer32 UNITS "nF" MAX-ACCESS read-only STATUS current DESCRIPTION "Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 21 } mltTestCapacitanceCeqrg OBJECT-TYPE SYNTAX Integer32 UNITS "nF" MAX-ACCESS read-only STATUS current DESCRIPTION "Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 22 } mltTestResistanceRtr OBJECT-TYPE SYNTAX Integer32 UNITS "Ohm" MAX-ACCESS read-only STATUS current DESCRIPTION "DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state ` only." ::= { mltTestResultsEntry 23 } mltTestResistanceRtg OBJECT-TYPE SYNTAX Integer32 UNITS "Ohm" MAX-ACCESS read-only STATUS current DESCRIPTION "DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 24 } mltTestResistanceRrg OBJECT-TYPE SYNTAX Integer32 UNITS "Ohm" MAX-ACCESS read-only STATUS current DESCRIPTION "DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 25 } mltTestGr909HazardousPotentialTestResult OBJECT-TYPE SYNTAX MltTestPassFail MAX-ACCESS read-only STATUS current DESCRIPTION "This test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fail. This test is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 26 } mltTestGr909ForeignEmfTestResult OBJECT-TYPE SYNTAX MltTestPassFail MAX-ACCESS read-only STATUS current DESCRIPTION "This test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fail. This test is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 27 } mltTestGr909FuseTestTipFuse OBJECT-TYPE SYNTAX MltTestPassFail MAX-ACCESS read-only STATUS obsolete DESCRIPTION "This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. This object is obsolete. Object name was changed." ::= { mltTestResultsEntry 28 } mltTestGr909FuseTestRingFuse OBJECT-TYPE SYNTAX MltTestPassFail MAX-ACCESS read-only STATUS obsolete DESCRIPTION "This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. This object is obsolete. Object name was changed." ::= { mltTestResultsEntry 29 } mltTestFuseTestTipFuse OBJECT-TYPE SYNTAX MltTestPassFail MAX-ACCESS read-only STATUS current DESCRIPTION "This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 38 } mltTestFuseTestRingFuse OBJECT-TYPE SYNTAX MltTestPassFail MAX-ACCESS read-only STATUS current DESCRIPTION "This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 39 } mltTestGr909ResistiveFaultTestResult OBJECT-TYPE SYNTAX MltTestPassFail MAX-ACCESS read-only STATUS current DESCRIPTION "This test fails if the T-R, T-G or R-G dc resistance is less than 150k ohm. This test will not be performed if fuse test fails or alarm is present. This test will return pass/fail. This test is intrusive and will be available in shutdown state only." ::= { mltTestResultsEntry 30 } mltTestGr909ReceiverOffhookTestResult OBJECT-TYPE SYNTAX MltTestPassFail MAX-ACCESS read-only STATUS current DESCRIPTION "This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only. " ::= { mltTestResultsEntry 31 } mltTestGr909ReceiverOffhookTestResistance1 OBJECT-TYPE SYNTAX Integer32 UNITS "Ohm" MAX-ACCESS read-only STATUS current DESCRIPTION "This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only. " ::= { mltTestResultsEntry 32 } mltTestGr909ReceiverOffhookTestResistance2 OBJECT-TYPE SYNTAX Integer32 UNITS "Ohm" MAX-ACCESS read-only STATUS current DESCRIPTION "This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only. " ::= { mltTestResultsEntry 33 } mltTestGr909ReceiverOffhookTestDifference OBJECT-TYPE SYNTAX Integer32 UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only. " ::= { mltTestResultsEntry 34 } mltTestGr909RingerTestResult OBJECT-TYPE SYNTAX MltTestRingerResult MAX-ACCESS read-only STATUS current DESCRIPTION "This test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or alarm is present. This test will report passed/fail and the REN number. This parameter is intrusive and will be available in shutdown state shutdown only." ::= { mltTestResultsEntry 35 } mltTestGr909RingerTestRen OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 REN" MAX-ACCESS read-only STATUS current DESCRIPTION "This test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or alarm is present. This test will report passed/fail and the REN number. This parameter is intrusive and will be available in shutdown state shutdown only." ::= { mltTestResultsEntry 36 } mltTestErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates GNK and/or OTEMP alarms active when test was run." ::= { mltTestResultsEntry 37 } -- mlt active mode voltages results table mltActiveModeVoltagesResultsTable OBJECT-TYPE SYNTAX SEQUENCE OF MltActiveModeVoltagesResultsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides results of the mlt active mode voltages test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured." ::= { mltTestResults 3 } mltActiveModeVoltagesResultsEntry OBJECT-TYPE SYNTAX MltActiveModeVoltagesResultsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry holding information about results of mlt active mode voltages test." INDEX { mltTestPort } ::= { mltActiveModeVoltagesResultsTable 1 } MltActiveModeVoltagesResultsEntry ::= SEQUENCE { mltActiveModeVoltagesVdctr Integer32, mltActiveModeVoltagesVdctg Integer32, mltActiveModeVoltagesVdcrg Integer32, mltActiveModeVoltagesVactr Integer32, mltActiveModeVoltagesVactg Integer32, mltActiveModeVoltagesVacrg Integer32, mltActiveModeVoltagesErrors OCTET STRING } mltActiveModeVoltagesVdctr OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vdc" MAX-ACCESS read-only STATUS current DESCRIPTION "Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only." ::= { mltActiveModeVoltagesResultsEntry 1 } mltActiveModeVoltagesVdctg OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vdc" MAX-ACCESS read-only STATUS current DESCRIPTION "Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only." ::= { mltActiveModeVoltagesResultsEntry 2 } mltActiveModeVoltagesVdcrg OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vdc" MAX-ACCESS read-only STATUS current DESCRIPTION "Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only." ::= { mltActiveModeVoltagesResultsEntry 3 } mltActiveModeVoltagesVactr OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vrms" MAX-ACCESS read-only STATUS current DESCRIPTION "Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only." ::= { mltActiveModeVoltagesResultsEntry 4 } mltActiveModeVoltagesVactg OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vrms" MAX-ACCESS read-only STATUS current DESCRIPTION "Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only." ::= { mltActiveModeVoltagesResultsEntry 5 } mltActiveModeVoltagesVacrg OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vrms" MAX-ACCESS read-only STATUS current DESCRIPTION "Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only." ::= { mltActiveModeVoltagesResultsEntry 6 } mltActiveModeVoltagesErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates GNK and/or OTEMP alarms active when test was run." ::= { mltActiveModeVoltagesResultsEntry 7 } -- mlt high impedance mode voltages results table mltHighImpedanceModeVoltagesResultsTable OBJECT-TYPE SYNTAX SEQUENCE OF MltHighImpedanceModeVoltagesResultsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured." ::= { mltTestResults 4 } mltHighImpedanceModeVoltagesResultsEntry OBJECT-TYPE SYNTAX MltHighImpedanceModeVoltagesResultsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry holding information about results of mlt high impedance mode voltages test." INDEX { mltTestPort } ::= { mltHighImpedanceModeVoltagesResultsTable 1 } MltHighImpedanceModeVoltagesResultsEntry ::= SEQUENCE { mltHighImpedanceModeVoltagesVdctr Integer32, mltHighImpedanceModeVoltagesVdctg Integer32, mltHighImpedanceModeVoltagesVdcrg Integer32, mltHighImpedanceModeVoltagesVactr Integer32, mltHighImpedanceModeVoltagesVactg Integer32, mltHighImpedanceModeVoltagesVacrg Integer32, mltHighImpedanceModeVoltagesErrors OCTET STRING } mltHighImpedanceModeVoltagesVdctr OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vdc" MAX-ACCESS read-only STATUS current DESCRIPTION "High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only." ::= { mltHighImpedanceModeVoltagesResultsEntry 1 } mltHighImpedanceModeVoltagesVdctg OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vdc" MAX-ACCESS read-only STATUS current DESCRIPTION "High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only." ::= { mltHighImpedanceModeVoltagesResultsEntry 2 } mltHighImpedanceModeVoltagesVdcrg OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vdc" MAX-ACCESS read-only STATUS current DESCRIPTION "High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only." ::= { mltHighImpedanceModeVoltagesResultsEntry 3 } mltHighImpedanceModeVoltagesVactr OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vrms" MAX-ACCESS read-only STATUS current DESCRIPTION "High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only." ::= { mltHighImpedanceModeVoltagesResultsEntry 4 } mltHighImpedanceModeVoltagesVactg OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vrms" MAX-ACCESS read-only STATUS current DESCRIPTION "High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only." ::= { mltHighImpedanceModeVoltagesResultsEntry 5 } mltHighImpedanceModeVoltagesVacrg OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Vrms" MAX-ACCESS read-only STATUS current DESCRIPTION "High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only." ::= { mltHighImpedanceModeVoltagesResultsEntry 6 } mltHighImpedanceModeVoltagesErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates GNK and/or OTEMP alarms active when test was run." ::= { mltHighImpedanceModeVoltagesResultsEntry 7 } -- mlt DC resistance results table mltDcResistanceResultsTable OBJECT-TYPE SYNTAX SEQUENCE OF MltDcResistanceResultsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides result of the DC resistance test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. Also, a resistance value of 9999 means that the result was greater than 1000 kOhms, but the exact value could not be measured." ::= { mltTestResults 5 } mltDcResistanceResultsEntry OBJECT-TYPE SYNTAX MltDcResistanceResultsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry holding information about results of mlt DC resistance test." INDEX { mltTestPort } ::= { mltDcResistanceResultsTable 1 } MltDcResistanceResultsEntry ::= SEQUENCE { mltDcResistanceRtr Integer32, mltDcResistanceRtg Integer32, mltDcResistanceRrg Integer32, mltDcResistanceErrors OCTET STRING } mltDcResistanceRtr OBJECT-TYPE SYNTAX Integer32 UNITS "Ohm" MAX-ACCESS read-only STATUS current DESCRIPTION "DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only." ::= { mltDcResistanceResultsEntry 1 } mltDcResistanceRtg OBJECT-TYPE SYNTAX Integer32 UNITS "Ohm" MAX-ACCESS read-only STATUS current DESCRIPTION "DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only." ::= { mltDcResistanceResultsEntry 2 } mltDcResistanceRrg OBJECT-TYPE SYNTAX Integer32 UNITS "Ohm" MAX-ACCESS read-only STATUS current DESCRIPTION "DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only." ::= { mltDcResistanceResultsEntry 3 } mltDcResistanceErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates GNK and/or OTEMP alarms active when test was run." ::= { mltDcResistanceResultsEntry 4 } -- mlt capacitance results table mltCapacitanceResultsTable OBJECT-TYPE SYNTAX SEQUENCE OF MltCapacitanceResultsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured." ::= { mltTestResults 6 } mltCapacitanceResultsEntry OBJECT-TYPE SYNTAX MltCapacitanceResultsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry holding information about results of mlt capacitance test." INDEX { mltTestPort } ::= { mltCapacitanceResultsTable 1 } MltCapacitanceResultsEntry ::= SEQUENCE { mltCapacitanceCeqtr Integer32, mltCapacitanceCeqtg Integer32, mltCapacitanceCeqrg Integer32, mltCapacitanceErrors OCTET STRING } mltCapacitanceCeqtr OBJECT-TYPE SYNTAX Integer32 UNITS "nF" MAX-ACCESS read-only STATUS current DESCRIPTION "Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only." ::= { mltCapacitanceResultsEntry 1 } mltCapacitanceCeqtg OBJECT-TYPE SYNTAX Integer32 UNITS "nF" MAX-ACCESS read-only STATUS current DESCRIPTION "Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only." ::= { mltCapacitanceResultsEntry 2 } mltCapacitanceCeqrg OBJECT-TYPE SYNTAX Integer32 UNITS "nF" MAX-ACCESS read-only STATUS current DESCRIPTION "Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only." ::= { mltCapacitanceResultsEntry 3 } mltCapacitanceErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates GNK and/or OTEMP alarms active when test was run." ::= { mltCapacitanceResultsEntry 4 } -- mlt loop detect results table mltLoopDetectResultsTable OBJECT-TYPE SYNTAX SEQUENCE OF MltLoopDetectResultsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides result of the mlt loop detect test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured." ::= { mltTestResults 7 } mltLoopDetectResultsEntry OBJECT-TYPE SYNTAX MltLoopDetectResultsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry holding information about results of mlt loop detect test." INDEX { mltTestPort } ::= { mltLoopDetectResultsTable 1 } MltLoopDetectResultsEntry ::= SEQUENCE { mltLoopDetectLoopCapacitance Integer32, mltLoopDetectDetectionThreshold Integer32, mltLoopDetectLoopDetected MltTestYesNo, mltLoopDetectErrors OCTET STRING } mltLoopDetectLoopCapacitance OBJECT-TYPE SYNTAX Integer32 UNITS "nF" MAX-ACCESS read-only STATUS current DESCRIPTION "Loop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied,loop detection threshold of 10 nF will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only." ::= { mltLoopDetectResultsEntry 1 } mltLoopDetectDetectionThreshold OBJECT-TYPE SYNTAX Integer32 UNITS "nF" MAX-ACCESS read-only STATUS current DESCRIPTION "Loop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied, loop detection threshold of 10 nF will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only." ::= { mltLoopDetectResultsEntry 2 } mltLoopDetectLoopDetected OBJECT-TYPE SYNTAX MltTestYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Loop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied, loop detection threshold of 10 nF will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only." ::= { mltLoopDetectResultsEntry 3 } mltLoopDetectErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates GNK and/or OTEMP alarms active when test was run." ::= { mltLoopDetectResultsEntry 4 } -- mlt loop length results table mltLoopLengthResultsTable OBJECT-TYPE SYNTAX SEQUENCE OF MltLoopLengthResultsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides result of the mlt loop length test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured." ::= { mltTestResults 8 } mltLoopLengthResultsEntry OBJECT-TYPE SYNTAX MltLoopLengthResultsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry holding information about results of mlt loop length test." INDEX { mltTestPort } ::= { mltLoopLengthResultsTable 1 } MltLoopLengthResultsEntry ::= SEQUENCE { mltLoopLengthCapacitanceFactor Integer32, mltLoopLengthLoopCapacitance Integer32, mltLoopLengthLoopLength Integer32, mltLoopLengthUncompensatedLoopCapacitance Integer32, mltLoopLengthUncompensatedLoopLength Integer32, mltLoopLengthErrors OCTET STRING } mltLoopLengthCapacitanceFactor OBJECT-TYPE SYNTAX Integer32 UNITS "nF/mile" MAX-ACCESS read-only STATUS current DESCRIPTION "Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only." ::= { mltLoopLengthResultsEntry 1 } mltLoopLengthLoopCapacitance OBJECT-TYPE SYNTAX Integer32 UNITS "nF" MAX-ACCESS read-only STATUS current DESCRIPTION "Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. " ::= { mltLoopLengthResultsEntry 2 } mltLoopLengthLoopLength OBJECT-TYPE SYNTAX Integer32 UNITS "ft" MAX-ACCESS read-only STATUS current DESCRIPTION "Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. " ::= { mltLoopLengthResultsEntry 3 } mltLoopLengthUncompensatedLoopCapacitance OBJECT-TYPE SYNTAX Integer32 UNITS "nF" MAX-ACCESS read-only STATUS current DESCRIPTION "Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. This value has no DSL correction." ::= { mltLoopLengthResultsEntry 4 } mltLoopLengthUncompensatedLoopLength OBJECT-TYPE SYNTAX Integer32 UNITS "ft" MAX-ACCESS read-only STATUS current DESCRIPTION "Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. This value has no DSL correction." ::= { mltLoopLengthResultsEntry 5 } mltLoopLengthErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates GNK and/or OTEMP alarms active when test was run." ::= { mltLoopLengthResultsEntry 6 } -- notifications mltTestCompletedNotification NOTIFICATION-TYPE OBJECTS { mltTestIdentifier, mltTestPort, mltLastTestStatus, mltErrorText } STATUS current DESCRIPTION "This notification is sent to the requesting host when the requested mlt test has completed." ::= { mltTestNotifications 1 } END