CAMBIUM-PTP500-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, IpAddress, enterprises FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF DisplayString FROM SNMPv2-TC; cambium MODULE-IDENTITY LAST-UPDATED "201403141604Z" ORGANIZATION "Cambium Networks Ltd." CONTACT-INFO "Post: Simon Whitaker Cambium Networks Ltd. Unit B2, Linhay Business Park, Eastern Road, Ashburton, Devon. TQ13 7UP United Kingdom Phone: +44 (0) 1364 655 500 Email: simon.whitaker@cambiumnetworks.com" DESCRIPTION "MIB for 105Mbps non-line-of-sight (NLOS) wireless ethernet bridge." REVISION "201403141604Z" DESCRIPTION "PTP500-05-04: Added aAAControl group containing user table." REVISION "201302080838Z" DESCRIPTION "PTP500-05-03: Removed encryptionEnabledMismatchTrap. Renamed dfsChannelChangeTrap to channelChangeTrap." REVISION "201207091750Z" DESCRIPTION "PTP500-05-02: Corrected REVISION DESCRIPTION clause for 05-01." REVISION "201203281037Z" DESCRIPTION "PTP500-05-01: Updated ORGANIZATION and CONTACT-INFO. Replaced syslogLocalLog with syslogState. Added licensedCapacity and capacityLicenseMismatchTrap as part of SKU reduction. Added support for HTTPS. Added enabledDiagnosticAlarms attribute. Added support for syslog client. Removed lineOfSightModeInactive trap as part of SKU reduction (LOS no longer supported)." REVISION "201107131657Z" DESCRIPTION "PTP500-04-01: Added latitude, longitude, altitude, searchState, accessMethod and groupID." REVISION "201009221449Z" DESCRIPTION "PTP500-04-00: Changed root OID. Added SNMPv3 support, TDD sync, DFS Table, BIT STRING types now OCTET STRING. Added linkName, siteName. Renamed ethernet attributes & traps." REVISION "200905290925Z" DESCRIPTION "PTP500-03-02: Added Telecoms circuit emulation." REVISION "200811041022Z" DESCRIPTION "PTP500-03-00: Added Link Symmetry." REVISION "200806261644Z" DESCRIPTION "PTP500-02-00: Added IEEE 802.1q & 802.1ad VLAN support." REVISION "200804111808Z" DESCRIPTION "PTP500-01-00" ::= { enterprises 17713 } -- Groups in cambium ptp OBJECT IDENTIFIER ::= { cambium 1 } ptmp OBJECT IDENTIFIER ::= { cambium 2 } ptp500 OBJECT IDENTIFIER ::= { cambium 5 } -- Groups in ptp500 dfs OBJECT IDENTIFIER ::= { ptp500 3 } configuration OBJECT IDENTIFIER ::= { ptp500 5 } ethernet OBJECT IDENTIFIER ::= { ptp500 6 } telecom OBJECT IDENTIFIER ::= { ptp500 7 } licence OBJECT IDENTIFIER ::= { ptp500 8 } management OBJECT IDENTIFIER ::= { ptp500 9 } phyControl OBJECT IDENTIFIER ::= { ptp500 10 } phyStatus OBJECT IDENTIFIER ::= { ptp500 12 } alarms OBJECT IDENTIFIER ::= { ptp500 13 } smtp OBJECT IDENTIFIER ::= { ptp500 15 } snmpControl OBJECT IDENTIFIER ::= { ptp500 16 } sntp OBJECT IDENTIFIER ::= { ptp500 17 } reset OBJECT IDENTIFIER ::= { ptp500 18 } versions OBJECT IDENTIFIER ::= { ptp500 19 } pubStats OBJECT IDENTIFIER ::= { ptp500 20 } encryption OBJECT IDENTIFIER ::= { ptp500 22 } tDDControl OBJECT IDENTIFIER ::= { ptp500 23 } aAAControl OBJECT IDENTIFIER ::= { ptp500 25 } syslogControl OBJECT IDENTIFIER ::= { ptp500 24 } supplementary OBJECT IDENTIFIER ::= { ptp500 96 } ptpGroups OBJECT IDENTIFIER ::= { ptp500 98 } ptpTraps OBJECT IDENTIFIER ::= { ptp500 99 } ptpTrapPrefix OBJECT IDENTIFIER ::= { ptpTraps 0 } -- Compliance information -- ptpCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for the Cambium PTP MIB" MODULE -- this module MANDATORY-GROUPS { dfsGroup , configurationGroup , ethernetGroup , telecomGroup , licenceGroup , managementGroup , phyControlGroup , phyStatusGroup , alarmsGroup , smtpGroup , snmpControlGroup , sntpGroup , resetGroup , versionsGroup , pubStatsGroup , encryptionGroup , tDDControlGroup , aAAControlGroup , syslogControlGroup , supplementaryGroup , notificationsGroup } ::= { ptp500 97 } dfsGroup OBJECT-GROUP OBJECTS { dfsTableNumber , dfsMeans , dfsNineNinePointNinePercentiles , dfsPeaks } STATUS current DESCRIPTION "The dfs object group." ::= { ptpGroups 3 } configurationGroup OBJECT-GROUP OBJECTS { iPAddress , subnetMask , gatewayIPAddress , targetMACAddress , masterSlaveMode , maximumTransmitPower , antennaGain , cableLoss , eIRP , channelBandwidth , remoteIPAddress , linkName , siteName , accessMethod , groupID } STATUS current DESCRIPTION "The configuration object group." ::= { ptpGroups 5 } ethernetGroup OBJECT-GROUP OBJECTS { dataPortAutoNegotiation , dataPortAutoNegAdvertisement , dataPortAutoMdix , dataPortStatus , dataPortSpeedAndDuplex , dataPortWirelessDownAlert , useVLANForManagementInterfaces , vLANManagementPriority , vLANManagementVID , vLANPriorityTableNumber , vLANPriorityQueueMapping } STATUS current DESCRIPTION "The ethernet object group." ::= { ptpGroups 6 } telecomGroup OBJECT-GROUP OBJECTS { telecomsInterface , telecomsChannelStatus , telecomsLineCode , telecomsCableLength , telecomsLoopback } STATUS current DESCRIPTION "The telecom object group." ::= { ptpGroups 7 } licenceGroup OBJECT-GROUP OBJECTS { regionCode , productVariant , productName , ethernetFiberSupport , frequencyVariant , bandwidthVariant , constantPowerSpectralDensity , sNMPv3Enable , licensedCapacity } STATUS current DESCRIPTION "The licence object group." ::= { ptpGroups 8 } managementGroup OBJECT-GROUP OBJECTS { installStatus , installArmState , tFTPServerIPAddress , tFTPServerPortNumber , tFTPSoftwareUpgradeFileName , tFTPStartSoftwareUpgrade , tFTPSoftwareUpgradeStatus , tFTPSoftwareUpgradeStatusText , tFTPSoftwareUpgradeStatusAdditionalText , hTTPAccessEnabled , telnetAccessEnabled , hTTPPortNumber , hTTPSPortNumber , telnetPortNumber , hTTPSAccessEnabled } STATUS current DESCRIPTION "The management object group." ::= { ptpGroups 9 } phyControlGroup OBJECT-GROUP OBJECTS { linkSymmetry , linkModeOptimisation , userConfiguredMaxModulationMode , remoteMaximumTransmitPower } STATUS current DESCRIPTION "The phyControl object group." ::= { ptpGroups 10 } phyStatusGroup OBJECT-GROUP OBJECTS { receivePower , vectorError , transmitPower , range , linkLoss , receiveChannel , transmitChannel , receiveModulationMode , transmitModulationMode , receiveFreqMHz , transmitFreqMHz , signalStrengthRatio , receiveFreqKHz , transmitFreqKHz , searchState } STATUS current DESCRIPTION "The phyStatus object group." ::= { ptpGroups 12 } alarmsGroup OBJECT-GROUP OBJECTS { unitOutOfCalibration , incompatibleRegionCodes , noWirelessChannelAvailable , wirelessLinkDisabledWarning , dataPortDisabledWarning , dataPortConfigurationMismatch , incompatibleMasterAndSlave , tDDSynchronizationStatus , tDDSynchronizationAlarm , linkModeOptimizationMismatch , capacityLicenseMismatch } STATUS current DESCRIPTION "The alarms object group." ::= { ptpGroups 13 } smtpGroup OBJECT-GROUP OBJECTS { sMTPEmailAlert , sMTPServerIPAddress , sMTPServerPortNumber , sMTPSourceEmailAddress , sMTPDestinationEmailAddress , sMTPEnabledMessages } STATUS current DESCRIPTION "The smtp object group." ::= { ptpGroups 15 } snmpControlGroup OBJECT-GROUP OBJECTS { sNMPPortNumber , sNMPCommunityString , sNMPTrapTableNumber , sNMPTrapVersion , sNMPEnabledTraps , enabledDiagnosticAlarms , sNMPSendAllTrapsAtStartup , sNMPTrapIPAddress , sNMPTrapPortNumber } STATUS current DESCRIPTION "The snmpControl object group." ::= { ptpGroups 16 } sntpGroup OBJECT-GROUP OBJECTS { sNTPState , sNTPServerIPAddress , sNTPServerPortNumber , sNTPPollInterval , sNTPSync , sNTPLastSync , systemClock , timeZone , daylightSaving } STATUS current DESCRIPTION "The sntp object group." ::= { ptpGroups 17 } resetGroup OBJECT-GROUP OBJECTS { systemReset } STATUS current DESCRIPTION "The reset object group." ::= { ptpGroups 18 } versionsGroup OBJECT-GROUP OBJECTS { softwareVersion , hardwareVersion , secondarySoftwareVersion , bootVersion } STATUS current DESCRIPTION "The versions object group." ::= { ptpGroups 19 } pubStatsGroup OBJECT-GROUP OBJECTS { receiveDataRate , transmitDataRate , aggregateDataRate , wirelessLinkAvailability , wirelessLinkStatus , byteErrorRatio , receiveModulationModeDetail } STATUS current DESCRIPTION "The pubStats object group." ::= { ptpGroups 20 } encryptionGroup OBJECT-GROUP OBJECTS { encryptionAlgorithm } STATUS current DESCRIPTION "The encryption object group." ::= { ptpGroups 22 } tDDControlGroup OBJECT-GROUP OBJECTS { tDDSynchronizationMode } STATUS current DESCRIPTION "The tDDControl object group." ::= { ptpGroups 23 } aAAControlGroup OBJECT-GROUP OBJECTS { userTableNumber , userName , userRole , userEnabled , userPassword } STATUS current DESCRIPTION "The aAAControl object group." ::= { ptpGroups 25 } syslogControlGroup OBJECT-GROUP OBJECTS { syslogClient , syslogState } STATUS current DESCRIPTION "The syslogControl object group." ::= { ptpGroups 24 } supplementaryGroup OBJECT-GROUP OBJECTS { longitude , latitude , altitude } STATUS current DESCRIPTION "The supplementary object group." ::= { ptpGroups 96 } notificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { channelChangeTrap , dfsImpulsiveInterferenceTrap , dataPortStatusTrap , telecomsChannelStatusTrap , telecomsLoopbackTrap , regionCodeTrap , installStatusTrap , installArmStateTrap , unitOutOfCalibrationTrap , incompatibleRegionCodesTrap , noWirelessChannelAvailableTrap , wirelessLinkDisabledWarningTrap , dataPortDisabledWarningTrap , dataPortConfigurationMismatchTrap , incompatibleMasterAndSlaveTrap , sNTPSyncTrap , tDDSynchronizationAlarmTrap , linkModeOptimizationMismatchTrap , capacityLicenseMismatchTrap , syslogStateTrap , syslogLocalNearlyFullTrap , syslogLocalWrappedTrap , syslogClientTrap } STATUS current DESCRIPTION "The notifications group." ::= { ptpGroups 99 } DfsTableEntry ::= SEQUENCE { dfsTableIndex INTEGER , dfsMeans Integer32 , dfsNineNinePointNinePercentiles Integer32 , dfsPeaks Integer32 } dfsTable OBJECT-TYPE SYNTAX SEQUENCE OF DfsTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " A table storing a snapshot of various DFS measurements for each channel" ::= { dfs 2 } dfsTableEntry OBJECT-TYPE SYNTAX DfsTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table DfsTable" INDEX { dfsTableIndex } ::= { dfsTable 1 } VLANPriorityTableEntry ::= SEQUENCE { vLANPriorityQueueMapping INTEGER , vLANPriorityTableIndex INTEGER } vLANPriorityTable OBJECT-TYPE SYNTAX SEQUENCE OF VLANPriorityTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " A priority queue mapping table. This is a list of packet queues indexed by VLAN priority." ::= { ethernet 15 } vLANPriorityTableEntry OBJECT-TYPE SYNTAX VLANPriorityTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table VLANPriorityTable" INDEX { vLANPriorityTableIndex } ::= { vLANPriorityTable 1 } SNMPTrapTableEntry ::= SEQUENCE { sNMPTrapTableIndex INTEGER , sNMPTrapIPAddress IpAddress , sNMPTrapPortNumber INTEGER } sNMPTrapTable OBJECT-TYPE SYNTAX SEQUENCE OF SNMPTrapTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " SNMP trap configuration table." ::= { snmpControl 4 } sNMPTrapTableEntry OBJECT-TYPE SYNTAX SNMPTrapTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table SNMPTrapTable" INDEX { sNMPTrapTableIndex } ::= { sNMPTrapTable 1 } UserTableEntry ::= SEQUENCE { userTableIndex INTEGER , userName OCTET STRING , userRole INTEGER , userEnabled INTEGER , userPassword OCTET STRING } userTable OBJECT-TYPE SYNTAX SEQUENCE OF UserTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The User Table Control group contains objects specifically for user account management." ::= { aAAControl 2 } userTableEntry OBJECT-TYPE SYNTAX UserTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table UserTable" INDEX { userTableIndex } ::= { userTable 1 } -- Dfs group attribute definitions -- dfsTableNumber OBJECT-TYPE SYNTAX INTEGER (1..63) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the dfsTable" ::= { dfs 1 } -- DfsTable group attribute definitions -- dfsTableIndex OBJECT-TYPE SYNTAX INTEGER (1..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "used to index values in the dfsTable." ::= { dfsTableEntry 1 } dfsMeans OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Snapshot of DFS means" ::= { dfsTableEntry 2 } dfsNineNinePointNinePercentiles OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Snapshot of DFS 99.9 percentiles" ::= { dfsTableEntry 3 } dfsPeaks OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Snapshot of DFS peaks" ::= { dfsTableEntry 4 } -- Configuration group attribute definitions -- iPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Internet protocol (IP) address. This address is used by the family of Internet protocols to uniquely identify the unit on a network. NB: A system reboot is required to activate changes to this attribute." ::= { configuration 1 } subnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "A subnet allows the flow of network traffic between hosts to be segregated based on a network configuration. By organizing hosts into logical groups, subnetting can improve network security and performance. NB: A system reboot is required to activate changes to this attribute" ::= { configuration 2 } gatewayIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of a computer on the current network that is currently acting as a network gateway. A gateway acts as an entrance / exit to packets from / to other networks. NB: A system reboot is required to activate changes to this attribute" ::= { configuration 3 } targetMACAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) MAX-ACCESS read-only STATUS current DESCRIPTION "MAC address of the PTP wireless unit forming the other end of the PTP link" ::= { configuration 4 } masterSlaveMode OBJECT-TYPE SYNTAX INTEGER { master(0), slave(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The PTP wireless link operates using a master and slave relationship" ::= { configuration 5 } maximumTransmitPower OBJECT-TYPE SYNTAX INTEGER (-100..27) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum transmit power the wireless unit is permitted to use when establishing and maintaining the wireless link" ::= { configuration 6 } antennaGain OBJECT-TYPE SYNTAX INTEGER (0..610) MAX-ACCESS read-write STATUS current DESCRIPTION "Antenna Gain. Expressed in 10ths of dBi. NB: This attribute is ignored for variants with an integral antenna." ::= { configuration 7 } cableLoss OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Loss in the cable between the ODU and the antenna. Expressed in 10ths of dB. NB: This attribute is ignored for variants with an integral antenna." ::= { configuration 8 } eIRP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Effective Isotropic Radiated Power (EIRP) describes the strength of the radio signal leaving the wireless unit. Expressed in 10ths of dBm" ::= { configuration 9 } channelBandwidth OBJECT-TYPE SYNTAX INTEGER { bw30MHz(0), bw15MHz(1), bw10MHz(2), bw5MHz(3), bw20MHz(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This control sets the bandwidth of the transmit and receive radio channels" ::= { configuration 11 } remoteIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP Address of the peer wireless unit" ::= { configuration 12 } linkName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the PTP link allocated by the System Administrator. Used to establish a connection with the correct PTP wireless unit at the other end of the link. NOTE: The link name MUST be the same at both ends of the PTP link." ::= { configuration 14 } siteName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "This field contains a user-provided description of the site name together with any additional notes" ::= { configuration 15 } accessMethod OBJECT-TYPE SYNTAX INTEGER { linkAccess(0), linkNameAccess(1), groupAccess(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This controls whether the link can be established between pre-paired Master-Slave using MAC addresses (Link Access) or by using link name (Link Name Access)" ::= { configuration 16 } groupID OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "When Access Method is set to Group Access, the Group ID identifies all the units belonging to the same group. Group Access is only supported on some platforms" ::= { configuration 17 } -- Ethernet group attribute definitions -- dataPortAutoNegotiation OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls whether the local Ethernet interface configuration is automatically negotiated or forced. Do not use a forced setting together with auto negotiation at the Ethernet link partner. If you want to run your Ethernet link at a fixed speed and duplex then you would normally leave auto negotiation enabled and only enable the single Auto Neg Advertisement option that you want the link to run in - FORCING ETHERNET CONFIGURATION IS A LAST RESORT WHICH SHOULD ONLY BE PERFORMED IF YOU ARE HAVING PROBLEMS WITH AUTO NEGOTIATION - AND YOU MUST ENSURE THAT YOU CONFIGURE BOTH THIS UNIT AND THE ETHERNET LINK PARTNER TO WHICH IT IS CONNECTED IDENTICALLY (THE LINK PARTNER MUST NOT HAVE AUTO NEGOTIATION ENABLED EITHER, OTHERWISE A DUPLEX MISMATCH WILL OCCUR). NB: The new setting will only take effect after a system reboot." ::= { ethernet 1 } dataPortAutoNegAdvertisement OBJECT-TYPE SYNTAX BITS { negInvalid(2), neg10MbpsHalfDuplex(3), neg10MbpsFullDuplex(4), neg100MbpsHalfDuplex(5), neg100MbpsFullDuplex(6), negUnknown1(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This sets the different Ethernet configurations that will be advertised during auto negotiation. NB: The new setting will only take effect after a system reboot. WARNING: Duplex mismatch may result if both ends of the Ethernet link do not have the same settings. Do not auto negotiation together with a fixed setting at the Ethernet link partner. WARNING: Make sure that you select option(s) that you know your connected equipment can cater for!" ::= { ethernet 2 } dataPortAutoMdix OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This enables/disables the Auto MDI/MDIX capability. NB: The new setting will only take effect after a system reboot" ::= { ethernet 3 } dataPortStatus OBJECT-TYPE SYNTAX INTEGER { down(0), copperLinkUp(1), fiberLinkUp(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of the Ethernet link. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ethernet 4 } dataPortSpeedAndDuplex OBJECT-TYPE SYNTAX INTEGER { speed1000MbpsFullDuplex(0), speed100MbpsFullDuplex(1), speed100MbpsHalfDuplex(2), speed10MbpsFullDuplex(3), speed10MbpsHalfDuplex(4), speedUnknown6(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current speed and duplex of the Ethernet link" ::= { ethernet 5 } dataPortWirelessDownAlert OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "When enabled, this causes the Ethernet link to be dropped briefly when the wireless link drops. This is so that spanning tree algorithms can quickly detect that there is a problem." ::= { ethernet 6 } useVLANForManagementInterfaces OBJECT-TYPE SYNTAX INTEGER { noVLANTagging(0), iEEE8021QTaggedCTagType8100(1), iEEE8021adTaggedSTagorBTagType88a8(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls whether the management interfaces (WWW/SNMP/SMTP/SNTP) use VLAN tags or not. NB: The new setting will only take effect after a system reboot" ::= { ethernet 7 } vLANManagementPriority OBJECT-TYPE SYNTAX INTEGER (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "This VLAN Priority (0-7) will be included in packets generated by the management interfaces. NB: The new setting will only take effect after a system reboot" ::= { ethernet 8 } vLANManagementVID OBJECT-TYPE SYNTAX INTEGER (0..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "This VLAN VID (0-4094) will be included in packets generated by the management interfaces. NB: The new setting will only take effect after a system reboot" ::= { ethernet 11 } vLANPriorityTableNumber OBJECT-TYPE SYNTAX INTEGER (9) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the vLANPriorityTable." ::= { ethernet 14 } -- VLANPriorityTable group attribute definitions -- vLANPriorityQueueMapping OBJECT-TYPE SYNTAX INTEGER { q0(0), q1(1), q2(2), q3(3), q4(4), q5(5), q6(6), q7(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Mapping of VLAN priority flag to packet queue. The higher the queue number the greater its priority." ::= { vLANPriorityTableEntry 1 } vLANPriorityTableIndex OBJECT-TYPE SYNTAX INTEGER { p0(1), p1(2), p2(3), p3(4), p4(5), p5(6), p6(7), p7(8), untagged(9) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "VLAN priority flag, used to index values in the vLANPriorityTable." ::= { vLANPriorityTableEntry 2 } -- Telecom group attribute definitions -- telecomsInterface OBJECT-TYPE SYNTAX INTEGER { none(0), e1(1), t1(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The line interface type. If this is set to 'None' then the telecoms interfaces are disabled, and the telecom group attributes will be ignored." ::= { telecom 1 } telecomsChannelStatus OBJECT-TYPE SYNTAX INTEGER { disabled(0), noSignalLocal(1), noSignalRemote(2), noSignalLocalandRemote(3), up(4), remoteTiming(5), noSignalLocalandRemoteTiming(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of telecoms channel. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { telecom 2 } telecomsLineCode OBJECT-TYPE SYNTAX INTEGER { aMI(0), b8ZSHDB3(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The line code setting of the telecoms interface. This must match the setting of the device connected to this interface" ::= { telecom 4 } telecomsCableLength OBJECT-TYPE SYNTAX INTEGER { feet133(0), feet266(1), feet399(2), feet533(3), feet655(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The length of the cable connected to the telecoms interface, measured in feet" ::= { telecom 6 } telecomsLoopback OBJECT-TYPE SYNTAX INTEGER { none(0), copper(1), wireless(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The loopback status of telecoms channel. This is intended for installation testing and should be set to 'None' for normal operation. The wire connections to a unit can be tested by applying a 'Copper' loopback to the local unit. The wireless connection to the remote unit can be tested by applying a 'Wireless' loopback to the remote unit with no loopback on the local unit. When applying a wireless loopback, please ensure that the other end of the link has a loopback setting of 'None'. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { telecom 8 } -- Licence group attribute definitions -- regionCode OBJECT-TYPE SYNTAX INTEGER { regionCodeInvalid(0), regionCode1(1), regionCode2(2), regionCode3(3), regionCode4(4), regionCode5(5), regionCode6(6), regionCode7(7), regionCode8(8), regionCode9(9), regionCode10(10), regionCode11(11), regionCode12(12), regionCode13(13), regionCode14(14), regionCode15(15), regionCode16(16), regionCode17(17), regionCode18(18), regionCode19(19), regionCode20(20), regionCode21(21), regionCode22(22), regionCode23(23), regionCode24(24), regionCode25(25), regionCode26(26), regionCode27(27), regionCode28(28), regionCode29(29), regionCode30(30), regionCode31(31) } MAX-ACCESS read-only STATUS current DESCRIPTION "The region code prohibits the wireless unit from operating outside the regulated limits. An invalid region code indicates a corrupted licence key. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { licence 1 } productVariant OBJECT-TYPE SYNTAX INTEGER { pTPxx400Full(0), pTPxx400Deprecated1(1), pTPxx400Deprecated2(2), pTPxx400Lite(3), spare1(4), pTPxx300(5), spare2(6), spare3(7), pTPxx500FullDeprecated(8), pTPxx500LiteDeprecated(9), pTPxx500(10), pTPxx600Lite(11), pTPxx600Full(12), spare5(13), spare6(14), pTP800(15) } MAX-ACCESS read-only STATUS current DESCRIPTION "The product variant" ::= { licence 2 } productName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the product variant" ::= { licence 3 } ethernetFiberSupport OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet fiber support availability on this wireless unit" ::= { licence 4 } frequencyVariant OBJECT-TYPE SYNTAX INTEGER { freq5800MHz(0), freq5400MHz(1), freq4900MHz(2), freq2500MHz(3), freq5800MHz2(4), freq5400MHz2(5), freq4500MHz(6), freq5900MHz(7), freq5200MHz(8), freq5100MHz(9), freq4800MHz(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "Frequency variant of the wireless unit" ::= { licence 5 } bandwidthVariant OBJECT-TYPE SYNTAX INTEGER { bw30MHz(0), bw15MHz(1), bw10MHz(2), bw5MHz(3), bw20MHz(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Bandwidth variant of the wireless unit" ::= { licence 6 } constantPowerSpectralDensity OBJECT-TYPE SYNTAX INTEGER { constant(0), fullPower(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Constant power spectral density mode control" ::= { licence 7 } sNMPv3Enable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "SNMPv3 availability control" ::= { licence 9 } licensedCapacity OBJECT-TYPE SYNTAX INTEGER { capacity25Mbps(0), capacity52Mbps(1), capacity105Mbps(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum allowable data rate for ethernet frames permitted by the licence key. The actual data rate depends upon the prevailing wireless conditions" ::= { licence 11 } -- Management group attribute definitions -- installStatus OBJECT-TYPE SYNTAX INTEGER { ok(0), wrongPeer(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "A non-zero value indicates that signalling was received with the wrong MAC address or a mismatched link name. NB: It is very unusual to detect this, because units with mis-configured Target MAC Address will normally fail to establish a wireless link. However, rare circumstances may establish a partial wireless link and detect this situation. NB: A non-zero value on start-up, or a change of value during operation, may generate an SNMP trap and/or SMTP email alert" ::= { management 3 } installArmState OBJECT-TYPE SYNTAX INTEGER { disarmed(0), armed(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if the unit is being installed. NB: a value other than 'disarmed' on startup, or a change of state during operation may generate an SNMP trap and/or SMTP email alert" ::= { management 4 } tFTPServerIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP address of the TFTP Server from which the TFTP Software Upgrade File Name will be retrieved" ::= { management 5 } tFTPServerPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The port number of the TFTP Server from which the TFTP Software Upgrade File Name will be retrieved" ::= { management 6 } tFTPSoftwareUpgradeFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..127)) MAX-ACCESS read-write STATUS current DESCRIPTION "Filename of the Software Upgrade to be loaded from the TFTP Server" ::= { management 7 } tFTPStartSoftwareUpgrade OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Write '1' to this attribute to start the TFTP software upgrade process. The attribute will be reset to 0 when the upgrade process has finished" ::= { management 8 } tFTPSoftwareUpgradeStatus OBJECT-TYPE SYNTAX INTEGER { idle(0), uploadinprogress(1), uploadsuccessfulprogrammingFLASH(2), upgradesuccessfulreboottorunthenewsoftwareimage(3), upgradefailed(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of the TFTP Software upgrade process" ::= { management 9 } tFTPSoftwareUpgradeStatusText OBJECT-TYPE SYNTAX DisplayString (SIZE(0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Descriptive text describing the status of the TFTP Software upgrade process, including any error details" ::= { management 10 } tFTPSoftwareUpgradeStatusAdditionalText OBJECT-TYPE SYNTAX DisplayString (SIZE(0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Any additional text describing the status of the TFTP Software upgrade process, including any error details" ::= { management 11 } hTTPAccessEnabled OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls whether or not HTTP access is enabled, i.e. if this is disabled (0) then the unit will not respond to any requests on the HTTP port. Remote management via HTTPS is not affected by this setting. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = Enabled)" ::= { management 12 } telnetAccessEnabled OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls whether or not Telnet access is enabled, i.e. if this is disabled (0) then the unit will not respond to any requests on the TELNET port. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = Disabled)" ::= { management 13 } hTTPPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This controls the port number for HTTP access. A value of zero will use the default port number. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = 80)" ::= { management 14 } hTTPSPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This controls the port number for HTTPS access. A value of zero will use the default port number. Availability of HTTPS is controlled via the Licence Key. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = 443)" ::= { management 15 } telnetPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This controls the port number for TELNET access. A value of zero will use the default port number. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = 23)" ::= { management 16 } hTTPSAccessEnabled OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls whether or not HTTPS access is enabled, i.e. if this is disabled (0) then the unit will not respond to any requests on the HTTPS port. Remote management via HTTP is not affected by this setting. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = Enabled)" ::= { management 17 } -- PhyControl group attribute definitions -- linkSymmetry OBJECT-TYPE SYNTAX INTEGER { symmetryAdaptive(0), symmetry3to1(1), symmetry1to1(2), symmetry1to3(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "In fixed asymmetric mode (3 to 1) the transmit time is three times as long as the receive time. In fixed symmetric mode (1 to 1) the unit spends an equal amount of time transmitting and receiving. In fixed asymmetric mode (1 to 3) the receive time is three times as long as the transmit time. In adaptive mode the transmit and receive periods adjust with applied load. NB: only applicable for master nodes." ::= { phyControl 1 } linkModeOptimisation OBJECT-TYPE SYNTAX INTEGER { iPTraffic(0), tDMTraffic(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Optimises the wireless link behavior for the type of traffic to be carried. In 'IP Traffic' mode, the wireless link will minimise transmission errors by automatically adapting the modulation mode. In 'TDM Traffic' mode, the wireless link will minimise transmission latency and preserve throughput by maintaining a higher modulation mode in the presence of a limited number of errors. The 'TDM Traffic' mode is recommended for E1/T1 applications and connectionless protocols." ::= { phyControl 2 } userConfiguredMaxModulationMode OBJECT-TYPE SYNTAX INTEGER { modBpsk50percent(0), modQpsk50percent(1), modQpsk75percent(2), mod16qam50percent(3), mod16qam75percent(4), mod64qam67percent(5), mod64qam83percent(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum receive modulation mode controls the MAX mode used for adaptive modulation. NOTE: This attribute is automatically disabled when the installation agent is armed. To disarm the installation agent use the installation wizard" ::= { phyControl 3 } remoteMaximumTransmitPower OBJECT-TYPE SYNTAX INTEGER (-100..27) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum transmit power the remote wireless unit is permitted to use when establishing and maintaining the wireless link" ::= { phyControl 4 } -- PhyStatus group attribute definitions -- receivePower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Receive power expressed in tenths of a dBm" ::= { phyStatus 1 } vectorError OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The vector error measurement compares the received signal's IQ modulation characteristics to an ideal signal to determine the composite error vector magnitude. The value represented by this attribute is the average vector error over the previous second expressed in tenths of a dB" ::= { phyStatus 2 } transmitPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Transmit power expressed in tenths of a dBm" ::= { phyStatus 3 } range OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Distance between the two peer wireless units expressed in tenths of a kilometer" ::= { phyStatus 4 } linkLoss OBJECT-TYPE SYNTAX INTEGER (-500..500) MAX-ACCESS read-only STATUS current DESCRIPTION "The wireless link loss expressed in tenths of a dB" ::= { phyStatus 5 } receiveChannel OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION "Current active receive channel" ::= { phyStatus 6 } transmitChannel OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION "Current active transmit channel" ::= { phyStatus 7 } receiveModulationMode OBJECT-TYPE SYNTAX INTEGER { modAcquisition(0), modBpsk50percent(1), modQpsk50percentSingle(2), modQpsk75percentSingle(3), mod16qam50percentSingle(4), mod16qam75percentSingle(5), mod64qam67percentSingle(6), mod64qam83percentSingle(7), modReserved1(8), modQpsk50percentDual(9), modQpsk75percentDual(10), mod16qam50percentDual(11), mod16qam75percentDual(12), mod64qam67percentDual(13), mod64qam83percentDual(14), modReserved2(15) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current active receive modulation mode" ::= { phyStatus 8 } transmitModulationMode OBJECT-TYPE SYNTAX INTEGER { modAcquisition(0), modBpsk50percent(1), modQpsk50percentSingle(2), modQpsk75percentSingle(3), mod16qam50percentSingle(4), mod16qam75percentSingle(5), mod64qam67percentSingle(6), mod64qam83percentSingle(7), modReserved1(8), modQpsk50percentDual(9), modQpsk75percentDual(10), mod16qam50percentDual(11), mod16qam75percentDual(12), mod64qam67percentDual(13), mod64qam83percentDual(14), modReserved2(15) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current active transmit modulation mode" ::= { phyStatus 9 } receiveFreqMHz OBJECT-TYPE SYNTAX INTEGER (0..5925) MAX-ACCESS read-only STATUS current DESCRIPTION "Current receive frequency expressed in integer MHz" ::= { phyStatus 11 } transmitFreqMHz OBJECT-TYPE SYNTAX INTEGER (0..5925) MAX-ACCESS read-only STATUS current DESCRIPTION "Current transmit frequency expressed in integer MHz" ::= { phyStatus 12 } signalStrengthRatio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Signal strength ratio (Vertical / Horizontal) : the number of dB larger the Vertical antenna input is than the Horizontal antenna input expressed in tenths of a dB" ::= { phyStatus 13 } receiveFreqKHz OBJECT-TYPE SYNTAX INTEGER (0..5925000) MAX-ACCESS read-only STATUS current DESCRIPTION "Current receive frequency expressed as KHz" ::= { phyStatus 14 } transmitFreqKHz OBJECT-TYPE SYNTAX INTEGER (0..5925000) MAX-ACCESS read-only STATUS current DESCRIPTION "Current transmit frequency expressed as KHz" ::= { phyStatus 15 } searchState OBJECT-TYPE SYNTAX INTEGER { registering(0), searching(1), acquiring(2), registeringAcquiring2(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Search status of the wireless modem. 'Registering' means that the modem has locked to an OFDM signal, and the wireless link is up. 'Searching' means that no wireless signal has been detected. 'Acquiring' means that a wireless signal has been detected, but the modem has not locked to an OFDM signal." ::= { phyStatus 16 } -- Alarms group attribute definitions -- unitOutOfCalibration OBJECT-TYPE SYNTAX INTEGER { calibrated(0), partialCalibration(1), invalidCalibration(2), bandwidthvariantunsupportedPAsShutdown(3), outOfCalibrationPAsShutdown(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The unit is out of calibration" ::= { alarms 1 } incompatibleRegionCodes OBJECT-TYPE SYNTAX INTEGER { ok(0), incompatibleLicenceKeys(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The master and slave units have incompatible region codes. NB: Both units must have compatible licence keys" ::= { alarms 4 } noWirelessChannelAvailable OBJECT-TYPE SYNTAX INTEGER { ok(0), noWirelessChannelAvailable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Spectrum Management was unable to locate a suitable wireless channel to operate on" ::= { alarms 5 } wirelessLinkDisabledWarning OBJECT-TYPE SYNTAX INTEGER { ok(0), disabledBySNMPifAdminStatus(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The SNMP ifAdminStatus of the wireless interface has disabled wireless traffic" ::= { alarms 6 } dataPortDisabledWarning OBJECT-TYPE SYNTAX INTEGER { ok(0), disabledBySNMPifAdminStatus(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The SNMP ifAdminStatus of the Ethernet interface has disabled Ethernet traffic" ::= { alarms 7 } dataPortConfigurationMismatch OBJECT-TYPE SYNTAX INTEGER { noError(0), mismatchDetected(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The detection of Ethernet fragments (runt packets) when the link is in full duplex is an indication of an auto-negotiation or forced configuration mismatch" ::= { alarms 9 } incompatibleMasterAndSlave OBJECT-TYPE SYNTAX INTEGER { ok(0), incompatibleProductVariants(1), differentSoftwareVersionsRunning(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "A non-zero value indicates that the master and slave ends of a link are different hardware products, or have different software versions. NB: It is very unusual to detect this, because incompatible units will normally fail to establish a wireless link. However, some combinations may establish a partial wireless link and detect this situation. NB: A non-zero value may generate an SNMP trap and/or SMTP email alert" ::= { alarms 10 } tDDSynchronizationStatus OBJECT-TYPE SYNTAX INTEGER { locked(0), holdover(1), holdoverNotConnected(2), acquiringLock(3), noTimingReference(4), timingSystemNotConnected(5), initialising(6), clusterTimingMaster(7), tDDSyncNotActive(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "An alarm value (displayed in red) indicates that one of the following conditions has not been met (i) An external timing system is connected or internal timing has been configured. (ii) The timing system is providing a useable reference. (iii) The ODU is locked to this reference." ::= { alarms 11 } tDDSynchronizationAlarm OBJECT-TYPE SYNTAX INTEGER { ok(0), notSynchronized(1), timingSystemFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Not Synchronized indicates failure of the external timing system for a period greater than the holdover timer. TDD frame timing will have drifted, and this link may cause interference with other links in a synchronized network. Timing System Failure is an early warning, indicating that 80% of the holdover period has expired." ::= { alarms 13 } linkModeOptimizationMismatch OBJECT-TYPE SYNTAX INTEGER { ok(0), linkModeOptimizationMismatch(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The remote node of this link has been configured with a different link mode optimization" ::= { alarms 14 } capacityLicenseMismatch OBJECT-TYPE SYNTAX INTEGER { ok(0), mismatchDetected(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The local and remote units have different licensed capacity and/or the full capacity trial has been activated at only one unit. The wireless link is operating at the capacity of the lowest capacity unit" ::= { alarms 16 } -- Smtp group attribute definitions -- sMTPEmailAlert OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Simple Mail Transfer Protocol is used to send equipment alerts via email to a specified email address. This utility can only be configured by the system administrator" ::= { smtp 1 } sMTPServerIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP address of the SMTP server" ::= { smtp 2 } sMTPServerPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Port number of the SMTP server" ::= { smtp 3 } sMTPSourceEmailAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The 'from' email address used when constructing the automatically generated e-mail message" ::= { smtp 4 } sMTPDestinationEmailAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The 'to' email address used when constructing the automatically generated e-mail message" ::= { smtp 5 } sMTPEnabledMessages OBJECT-TYPE SYNTAX BITS { telecomsChannelUpDown(1), unknown6(2), dataPortUpDown(3), enabledDiagnosticAlarms(4), dFSImpulseInterference(5), channelChange(6), wirelessLinkUpDown(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls which SMTP messages the unit will send" ::= { smtp 6 } -- SnmpControl group attribute definitions -- sNMPPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The IP port number used to access the SNMP MIB (i.e. Gets and Sets) (default = 161). NB: A system reboot is required to activate changes to this attribute" ::= { snmpControl 1 } sNMPCommunityString OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The SNMP community string. NB: A system reboot is required to activate changes to this attribute" ::= { snmpControl 2 } sNMPTrapTableNumber OBJECT-TYPE SYNTAX INTEGER (2) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the sNMPTrapTable." ::= { snmpControl 3 } sNMPTrapVersion OBJECT-TYPE SYNTAX INTEGER { v1(0), v2c(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The SNMP protocol version to use for SNMP Traps. NB: A system reboot is required to activate changes to this attribute" ::= { snmpControl 5 } sNMPEnabledTraps OBJECT-TYPE SYNTAX BITS { unknown8(0), dataPortUpDown(1), authenticationFailure(2), enabledDiagnosticAlarms(3), dFSImpulseInterference(4), channelChange(5), wirelessLinkUpDown(6), coldStart(7), telecomsChannelUpDown(15) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls which SNMP Traps the unit will send" ::= { snmpControl 6 } enabledDiagnosticAlarms OBJECT-TYPE SYNTAX BITS { incompatibleMasterAndSlave(0), incompatibleRegionCodes(1), unknown6(2), unknown5(3), unitOutOfCalibration(4), installArmState(5), installStatus(6), regionCode(7), telecomsChannelStatus(8), unknown15(9), dataPortStatus(10), dataPortDisabledWarning(11), wirelessLinkDisabledWarning(12), sNTPSynchronizationFailed(13), noWirelessChannelAvailable(14), dataPortConfigurationMismatch(15), syslogClientDisabledWarning(16), licensedCapacityMismatch(17), syslogLocalWrapped(18), syslogLocalNearlyFull(19), syslogLocalEnableDisable(20), linkModeOptimizationMismatch(21), tDDSynchronizationAlarm(22), telecomsChannelLoopback(23) } MAX-ACCESS read-write STATUS current DESCRIPTION "Controls which individual diagnostic alarms are enabled. The unit may be configured to generate SNMP traps and/or SMTP email alerts for these enabled alarms by selecting 'Enabled Diagnostic Alarms' on the 'SNMP Enabled Traps' and/or 'SMTP Enabled Messages' attributes" ::= { snmpControl 7 } sNMPSendAllTrapsAtStartup OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether cleared traps are reported at start-up as well as raised traps. Only enabled traps will be reported. NB: Traps corresponding to transient events (i.e. not associated with an alarm or status value) are only sent when required and not at start-up." ::= { snmpControl 8 } -- SNMPTrapTable group attribute definitions -- sNMPTrapTableIndex OBJECT-TYPE SYNTAX INTEGER (1..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "SNMP trap value, used to index the SNMPTrapTable." ::= { sNMPTrapTableEntry 1 } sNMPTrapIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address to which all SNMP Traps are sent. An IP Address of 0.0.0.0 disables all TRAP generation. NB: A system reboot is required to activate changes to this attribute." ::= { sNMPTrapTableEntry 2 } sNMPTrapPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Destination port for SNMP Traps (default=162). A value of 0 will disable the trap receiver. NB: A system reboot is required to activate changes to this attribute." ::= { sNMPTrapTableEntry 3 } -- Sntp group attribute definitions -- sNTPState OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "SNTP control state" ::= { sntp 1 } sNTPServerIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of a valid SNTP server" ::= { sntp 2 } sNTPServerPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The IP port number of the SNTP server. Defaults to port 123." ::= { sntp 3 } sNTPPollInterval OBJECT-TYPE SYNTAX INTEGER (60..43200) MAX-ACCESS read-write STATUS current DESCRIPTION "The SNTP server polling interval" ::= { sntp 4 } sNTPSync OBJECT-TYPE SYNTAX INTEGER { noSync(0), inSync(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "If SNTP Sync fails then check the server settings in the Remote Management page, or disable SNTP. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { sntp 5 } sNTPLastSync OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Last SNTP sync time" ::= { sntp 6 } systemClock OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "System clock presented as local time" ::= { sntp 7 } timeZone OBJECT-TYPE SYNTAX INTEGER { gmtMinus1200(0), gmtMinus1130(1), gmtMinus1100(2), gmtMinus1030(3), gmtMinus1000(4), gmtMinus0930(5), gmtMinus0900(6), gmtMinus0830(7), gmtMinus0800(8), gmtMinus0730(9), gmtMinus0700(10), gmtMinus0630(11), gmtMinus0600(12), gmtMinus0530(13), gmtMinus0500(14), gmtMinus0430(15), gmtMinus0400(16), gmtMinus0330(17), gmtMinus0300(18), gmtMinus0230(19), gmtMinus0200(20), gmtMinus0130(21), gmtMinus0100(22), gmtMinus0030(23), gmtZero(24), gmtPlus0030(25), gmtPlus0100(26), gmtPlus0130(27), gmtPlus0200(28), gmtPlus0230(29), gmtPlus0300(30), gmtPlus0330(31), gmtPlus0400(32), gmtPlus0430(33), gmtPlus0500(34), gmtPlus0530(35), gmtPlus0600(36), gmtPlus0630(37), gmtPlus0700(38), gmtPlus0730(39), gmtPlus0800(40), gmtPlus0830(41), gmtPlus0900(42), gmtPlus0930(43), gmtPlus1000(44), gmtPlus1030(45), gmtPlus1100(46), gmtPlus1130(47), gmtPlus1200(48), gmtPlus1230(49), gmtPlus1300(50) } MAX-ACCESS read-write STATUS current DESCRIPTION "Time zone offsets from Greenwich Mean Time (GMT)" ::= { sntp 8 } daylightSaving OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Daylight Saving Time" ::= { sntp 9 } -- Reset group attribute definitions -- systemReset OBJECT-TYPE SYNTAX INTEGER { running(0), consoleReboot(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to '1' will cause a system reboot. NB: a system reboot will apply any pending new settings held in memory" ::= { reset 1 } -- Versions group attribute definitions -- softwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Current software version" ::= { versions 1 } hardwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware platform version" ::= { versions 2 } secondarySoftwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Secondary software version, used when the primary software image is invalid or erased" ::= { versions 3 } bootVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Boot code software version" ::= { versions 4 } -- PubStats group attribute definitions -- receiveDataRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average data rate over the last one second interval (kbps)" ::= { pubStats 1 } transmitDataRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average data rate over the last one second interval (kbps)" ::= { pubStats 2 } aggregateDataRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average data rate over the last one second interval (kbps)" ::= { pubStats 3 } wirelessLinkAvailability OBJECT-TYPE SYNTAX INTEGER (0..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "Link availability calculated since the last reset of the system counters, as a percentage multiplied by 10000 to give four decimal places of precision" ::= { pubStats 4 } wirelessLinkStatus OBJECT-TYPE SYNTAX INTEGER { up(0), registering(1), acquiring(2), searching(3), radarCAC(4), initialising(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of the wireless link" ::= { pubStats 5 } byteErrorRatio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Reciprocal of the byte error ratio calculated since the last reset of the system counters" ::= { pubStats 6 } receiveModulationModeDetail OBJECT-TYPE SYNTAX INTEGER { runningAtMaximumReceiveMode(0), runningAtUserConfiguredMaxModulationMode(1), restrictedBecauseInstallationIsArmed(2), restrictedBecauseOfByteErrorsOnTheWirelessLink(3), restrictedBecauseTheLinkParametersAreUpdating(4), restrictedBecauseChannelChangeIsInProgress(5), restrictedDueToTheLowEthernetLinkSpeed(6), runningAtMaximumReceiveModeForChannelBandwidth(7), limitedByTheWirelessConditions(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The reason for the current receive modulation mode" ::= { pubStats 7 } -- Encryption group attribute definitions -- encryptionAlgorithm OBJECT-TYPE SYNTAX INTEGER { none(0), aESRijndael(1), aES256bitRijndael(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Encryption Algorithm used by the wireless link. NB: A system reboot is required to activate changes to this attribute. NB: The same Encryption Algorithm must be configured at BOTH ends of the link for it to function correctly" ::= { encryption 1 } -- TDDControl group attribute definitions -- tDDSynchronizationMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "TDD Synchronization Mode selection" ::= { tDDControl 1 } -- AAAControl group attribute definitions -- userTableNumber OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the userTable" ::= { aAAControl 1 } -- UserTable group attribute definitions -- userTableIndex OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS not-accessible STATUS current DESCRIPTION "used to index values in the userTable." ::= { userTableEntry 1 } userName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "User name which must be entered, along with the appropriate password, in order to gain access to the system." ::= { userTableEntry 2 } userRole OBJECT-TYPE SYNTAX INTEGER { readOnly(0), systemAdministrator(1), securityOfficer(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Role of the selected user. A Security Officer has access to and can modify all settings. A System Administrator has access to and can modify all non-security settings. A Read Only user can view settings, but cannot make any changes." ::= { userTableEntry 3 } userEnabled OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable / Disable the selected user" ::= { userTableEntry 4 } userPassword OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "User password, which must be entered in order to gain access to the system." ::= { userTableEntry 5 } -- SyslogControl group attribute definitions -- syslogClient OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable the syslog client" ::= { syslogControl 1 } syslogState OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The syslog service has been enabled or disabled" ::= { syslogControl 2 } -- Supplementary group attribute definitions -- longitude OBJECT-TYPE SYNTAX DisplayString (SIZE(0..19)) MAX-ACCESS read-write STATUS current DESCRIPTION "The longitude of the unit, measured in decimal degrees. This object is set by the SNMP manager and has no internal function." ::= { supplementary 1 } latitude OBJECT-TYPE SYNTAX DisplayString (SIZE(0..19)) MAX-ACCESS read-write STATUS current DESCRIPTION "The latitude of the unit, measured in decimal degrees. This object is set by the SNMP manager and has no internal function." ::= { supplementary 2 } altitude OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The altitude of the unit, measured in metres. This object is set by the SNMP manager and has no internal function." ::= { supplementary 3 } -- Enterprise NOTIFICATION definitions -- channelChangeTrap NOTIFICATION-TYPE OBJECTS { receiveChannel } STATUS current DESCRIPTION "The PTP radio has changed wireless channel. This has been caused by either i) mandatory radar avoidance, a DFS impulsive interference event will also be detected, or ii) Dynamic Spectrum Optimization, (DSO) DSO improves link performance by selecting the most appropriate transmit and receive channels with the lowest level of interference." ::= { ptpTrapPrefix 1 } dfsImpulsiveInterferenceTrap NOTIFICATION-TYPE OBJECTS { receiveChannel } STATUS current DESCRIPTION "DFS impulsive interference detected event" ::= { ptpTrapPrefix 2 } dataPortStatusTrap NOTIFICATION-TYPE OBJECTS { dataPortStatus } STATUS current DESCRIPTION "Current status of the Ethernet link. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 3 } telecomsChannelStatusTrap NOTIFICATION-TYPE OBJECTS { telecomsChannelStatus } STATUS current DESCRIPTION "Current status of telecoms channel. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 4 } telecomsLoopbackTrap NOTIFICATION-TYPE OBJECTS { telecomsLoopback } STATUS current DESCRIPTION "The loopback status of telecoms channel. This is intended for installation testing and should be set to 'None' for normal operation. The wire connections to a unit can be tested by applying a 'Copper' loopback to the local unit. The wireless connection to the remote unit can be tested by applying a 'Wireless' loopback to the remote unit with no loopback on the local unit. When applying a wireless loopback, please ensure that the other end of the link has a loopback setting of 'None'. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 6 } regionCodeTrap NOTIFICATION-TYPE OBJECTS { regionCode } STATUS current DESCRIPTION "The region code prohibits the wireless unit from operating outside the regulated limits. An invalid region code indicates a corrupted licence key. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 8 } installStatusTrap NOTIFICATION-TYPE OBJECTS { installStatus } STATUS current DESCRIPTION "A non-zero value indicates that signalling was received with the wrong MAC address or a mismatched link name. NB: It is very unusual to detect this, because units with mis-configured Target MAC Address will normally fail to establish a wireless link. However, rare circumstances may establish a partial wireless link and detect this situation. NB: A non-zero value on start-up, or a change of value during operation, may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 9 } installArmStateTrap NOTIFICATION-TYPE OBJECTS { installArmState } STATUS current DESCRIPTION "Indicates if the unit is being installed. NB: a value other than 'disarmed' on startup, or a change of state during operation may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 10 } unitOutOfCalibrationTrap NOTIFICATION-TYPE OBJECTS { unitOutOfCalibration } STATUS current DESCRIPTION "The unit is out of calibration" ::= { ptpTrapPrefix 11 } incompatibleRegionCodesTrap NOTIFICATION-TYPE OBJECTS { incompatibleRegionCodes } STATUS current DESCRIPTION "The master and slave units have incompatible region codes. NB: Both units must have compatible licence keys" ::= { ptpTrapPrefix 14 } noWirelessChannelAvailableTrap NOTIFICATION-TYPE OBJECTS { noWirelessChannelAvailable } STATUS current DESCRIPTION "Spectrum Management was unable to locate a suitable wireless channel to operate on" ::= { ptpTrapPrefix 15 } wirelessLinkDisabledWarningTrap NOTIFICATION-TYPE OBJECTS { wirelessLinkDisabledWarning } STATUS current DESCRIPTION "The SNMP ifAdminStatus of the wireless interface has disabled wireless traffic" ::= { ptpTrapPrefix 16 } dataPortDisabledWarningTrap NOTIFICATION-TYPE OBJECTS { dataPortDisabledWarning } STATUS current DESCRIPTION "The SNMP ifAdminStatus of the Ethernet interface has disabled Ethernet traffic" ::= { ptpTrapPrefix 17 } dataPortConfigurationMismatchTrap NOTIFICATION-TYPE OBJECTS { dataPortConfigurationMismatch } STATUS current DESCRIPTION "The detection of Ethernet fragments (runt packets) when the link is in full duplex is an indication of an auto-negotiation or forced configuration mismatch" ::= { ptpTrapPrefix 19 } incompatibleMasterAndSlaveTrap NOTIFICATION-TYPE OBJECTS { incompatibleMasterAndSlave } STATUS current DESCRIPTION "A non-zero value indicates that the master and slave ends of a link are different hardware products, or have different software versions. NB: It is very unusual to detect this, because incompatible units will normally fail to establish a wireless link. However, some combinations may establish a partial wireless link and detect this situation. NB: A non-zero value may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 20 } sNTPSyncTrap NOTIFICATION-TYPE OBJECTS { sNTPSync } STATUS current DESCRIPTION "If SNTP Sync fails then check the server settings in the Remote Management page, or disable SNTP. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 21 } tDDSynchronizationAlarmTrap NOTIFICATION-TYPE OBJECTS { tDDSynchronizationAlarm } STATUS current DESCRIPTION "Not Synchronized indicates failure of the external timing system for a period greater than the holdover timer. TDD frame timing will have drifted, and this link may cause interference with other links in a synchronized network. Timing System Failure is an early warning, indicating that 80% of the holdover period has expired." ::= { ptpTrapPrefix 22 } linkModeOptimizationMismatchTrap NOTIFICATION-TYPE OBJECTS { linkModeOptimizationMismatch } STATUS current DESCRIPTION "The remote node of this link has been configured with a different link mode optimization" ::= { ptpTrapPrefix 25 } capacityLicenseMismatchTrap NOTIFICATION-TYPE OBJECTS { capacityLicenseMismatch } STATUS current DESCRIPTION "The local and remote units have different licensed capacity and/or the full capacity trial has been activated at only one unit. The wireless link is operating at the capacity of the lowest capacity unit" ::= { ptpTrapPrefix 27 } syslogStateTrap NOTIFICATION-TYPE OBJECTS { syslogState } STATUS current DESCRIPTION "The syslog service has been enabled or disabled" ::= { ptpTrapPrefix 30 } syslogLocalNearlyFullTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "The syslog local log is nearly full (90%)" ::= { ptpTrapPrefix 31 } syslogLocalWrappedTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "The syslog local log has wrapped" ::= { ptpTrapPrefix 32 } syslogClientTrap NOTIFICATION-TYPE OBJECTS { syslogClient } STATUS current DESCRIPTION "Enable or disable the syslog client" ::= { ptpTrapPrefix 33 } END