CAMBIUM-PTP600-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, IpAddress, enterprises FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF DisplayString FROM SNMPv2-TC InetAddress, InetAddressType FROM INET-ADDRESS-MIB; cambium MODULE-IDENTITY LAST-UPDATED "201403041414Z" ORGANIZATION "Cambium Networks Ltd." CONTACT-INFO "Post: Simon Whitaker Cambium Networks Ltd. Unit B2, Linhay Business Park, Eastern Road, Ashburton, Devon. TQ13 7UP United Kingdom Phone: +44 (0) 1364 655 500 Email: simon.whitaker@cambiumnetworks.com" DESCRIPTION "MIB for 300Mbps non-line-of-sight (NLOS) wireless ethernet bridge." REVISION "201403041414Z" DESCRIPTION "PTP600-10-07: Reinstated incompatibleRegionCodesTrap. Reinstated incompatibleMasterAndSlaveTrap. Reinstated encryptionEnabledMismatchTrap." REVISION "201309142338Z" DESCRIPTION "PTP600-10-06: Removed incompatibleRegionCodesTrap. Removed incompatibleMasterAndSlaveTrap. Removed encryptionEnabledMismatchTrap." REVISION "201208131812Z" DESCRIPTION "PTP600-10-04: Added ethernetBridgingStatus, ethernetBridgingAvailability. Added ethernetBridgingStatusAlarm, ethernetBridgingStatusAlarmTrap." REVISION "201205011158Z" DESCRIPTION "PTP600-10-03: make linkName & groupID read-write." REVISION "201202131238Z" DESCRIPTION "PTP600-10-01: Updated ORGANIZATION and CONTACT-INFO." REVISION "201111081347Z" DESCRIPTION "PTP600-10-00: Added new SNTP attributes, replace syslogLocalLog with syslogState. Add L2/L3 QoS attributes. Added securityLevel. Renamed vLANPriorityQueueMapping with ethernetPriorityQueueMapping. Added syslogClient and secureModeAlarm traps." REVISION "201012071328Z" DESCRIPTION "PTP600-09-10: Added searchState, accessMethod and groupID." REVISION "201011021333Z" DESCRIPTION "PTP600-09-02: Added latitude, longitude, altitude." REVISION "201007161541Z" DESCRIPTION "PTP600-09-01: Changed root OID. Renamed ethernet & fiber attributes & traps. Replaced vLANManagementVIDValidation with managementMode. Added linkName, siteName, hTTPSAccessEnabled, tDDSynchronizationMode. Added syslog attributes & traps. Added SNMPTrapTable for dual trap receivers." REVISION "201004231007Z" DESCRIPTION "PTP600-08-50: Security enhancements." REVISION "201002191855Z" DESCRIPTION "PTP600-08-04: Added SNMPv3 support, DFS Table, Automatic Tx Power Control. BIT STRING types now OCTET STRING." REVISION "200907101520Z" DESCRIPTION "PTP600-08-03: Added VLAN Priority Table, more read-only attributes, plus alarm tidy-up." REVISION "200902271711Z" DESCRIPTION "PTP600-08-01: Improve TDD Synchronization status and alarms." REVISION "200812151219Z" DESCRIPTION "PTP600-08-00: Support 4.8 & 4.9 GHz variant & 20 MHz bandwidth, Link Symmetry, TDD Synchronization." REVISION "200806301016Z" DESCRIPTION "PTP600-07-00: Added IEEE 802.1q & 802.1ad VLAN support." REVISION "200802290942Z" DESCRIPTION "PTP600-06-00: Added OOB, HTTP & telnet access controls." REVISION "200707311839Z" DESCRIPTION "PTP600-05-00: Added groups, attributes and notifications for diagnostic alarms." REVISION "200611231436Z" DESCRIPTION "PTP600-04-00: Converted to SMIv2." REVISION "200607241008Z" DESCRIPTION "PTP600-03-01" ::= { enterprises 17713 } -- Groups in cambium ptp OBJECT IDENTIFIER ::= { cambium 1 } ptmp OBJECT IDENTIFIER ::= { cambium 2 } ptp600 OBJECT IDENTIFIER ::= { cambium 6 } -- Groups in ptp600 dfs OBJECT IDENTIFIER ::= { ptp600 3 } bridge OBJECT IDENTIFIER ::= { ptp600 4 } configuration OBJECT IDENTIFIER ::= { ptp600 5 } ethernet OBJECT IDENTIFIER ::= { ptp600 6 } telecom OBJECT IDENTIFIER ::= { ptp600 7 } licence OBJECT IDENTIFIER ::= { ptp600 8 } management OBJECT IDENTIFIER ::= { ptp600 9 } phyControl OBJECT IDENTIFIER ::= { ptp600 10 } phyStatus OBJECT IDENTIFIER ::= { ptp600 12 } alarms OBJECT IDENTIFIER ::= { ptp600 13 } smtp OBJECT IDENTIFIER ::= { ptp600 15 } snmpControl OBJECT IDENTIFIER ::= { ptp600 16 } sntp OBJECT IDENTIFIER ::= { ptp600 17 } reset OBJECT IDENTIFIER ::= { ptp600 18 } versions OBJECT IDENTIFIER ::= { ptp600 19 } pubStats OBJECT IDENTIFIER ::= { ptp600 20 } encryption OBJECT IDENTIFIER ::= { ptp600 22 } tDDControl OBJECT IDENTIFIER ::= { ptp600 23 } aAAControl OBJECT IDENTIFIER ::= { ptp600 25 } syslogControl OBJECT IDENTIFIER ::= { ptp600 24 } supplementary OBJECT IDENTIFIER ::= { ptp600 96 } ptpGroups OBJECT IDENTIFIER ::= { ptp600 98 } ptpTraps OBJECT IDENTIFIER ::= { ptp600 99 } ptpTrapPrefix OBJECT IDENTIFIER ::= { ptpTraps 0 } -- Compliance information -- ptpCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for the Cambium PTP MIB" MODULE -- this module MANDATORY-GROUPS { dfsGroup , bridgeGroup , configurationGroup , ethernetGroup , telecomGroup , licenceGroup , managementGroup , phyControlGroup , phyStatusGroup , alarmsGroup , smtpGroup , snmpControlGroup , sntpGroup , resetGroup , versionsGroup , pubStatsGroup , encryptionGroup , tDDControlGroup , aAAControlGroup , syslogControlGroup , supplementaryGroup , notificationsGroup } ::= { ptp600 97 } dfsGroup OBJECT-GROUP OBJECTS { dfsTableNumber , dfsMeans , dfsNineNinePointNinePercentiles , dfsPeaks } STATUS current DESCRIPTION "The dfs object group." ::= { ptpGroups 3 } bridgeGroup OBJECT-GROUP OBJECTS { localPacketFiltering } STATUS current DESCRIPTION "The bridge object group." ::= { ptpGroups 4 } configurationGroup OBJECT-GROUP OBJECTS { iPv4Address , subnetMask , gatewayIPAddress , targetMACAddress , masterSlaveMode , maximumTransmitPower , antennaGain , cableLoss , eIRP , ethernetCappedMaxWirelessSpeed , channelBandwidth , remoteIPAddress , linkName , siteName , accessMethod , groupID , iPv6Address , iPVersion , iPv6AutoConfiguredLinkLocalAddress , iPv6PrefixLength , iPv6GatewayAddress , remoteInternetAddressType , remoteInternetAddress } STATUS current DESCRIPTION "The configuration object group." ::= { ptpGroups 5 } ethernetGroup OBJECT-GROUP OBJECTS { dataPortAutoNegotiation , dataPortAutoNegAdvertisement , dataPortAutoMdix , dataPortStatus , dataPortSpeedAndDuplex , dataPortWirelessDownAlert , useVLANForManagementInterfaces , vLANManagementPriority , vLANManagementVID , managementPortStatus , managementPortSpeedAndDuplex , ethernetPriorityTableNumber , l2CPPriorityTableNumber , iPDSCPPriorityTableNumber , mPLSTCPriorityTableNumber , managementMode , managementPortWirelessDownAlert , qOSPriorityScheme , unknownNetworkPriorityQueueMapping , dSCPManagementPriority , ethernetBridgingStatus , ethernetPriorityQueueMapping , l2CPPriorityQueueMapping , iPDSCPPriorityQueueMapping , mPLSTCPriorityQueueMapping } STATUS current DESCRIPTION "The ethernet object group." ::= { ptpGroups 6 } telecomGroup OBJECT-GROUP OBJECTS { telecomsInterface , telecomsChannelAStatus , telecomsChannelBStatus , channelALineCode , channelBLineCode , channelACableLength , channelBCableLength , channelALoopback , channelBLoopback , telecomsChannelSelection } STATUS current DESCRIPTION "The telecom object group." ::= { ptpGroups 7 } licenceGroup OBJECT-GROUP OBJECTS { regionCode , productVariant , productName , ethernetFiberSupport , frequencyVariant , bandwidthVariant , constantPowerSpectralDensity , sNMPv3Enable , hAZLOCConfiguration , securityLevel } STATUS current DESCRIPTION "The licence object group." ::= { ptpGroups 8 } managementGroup OBJECT-GROUP OBJECTS { targetRange , rangingMode , installStatus , installArmState , tFTPServerIPAddress , tFTPServerPortNumber , tFTPSoftwareUpgradeFileName , tFTPStartSoftwareUpgrade , tFTPSoftwareUpgradeStatus , tFTPSoftwareUpgradeStatusText , tFTPSoftwareUpgradeStatusAdditionalText , hTTPAccessEnabled , telnetAccessEnabled , hTTPPortNumber , hTTPSPortNumber , telnetPortNumber , hTTPSAccessEnabled , tFTPServerInternetAddressType , tFTPServerInternetAddress } STATUS current DESCRIPTION "The management object group." ::= { ptpGroups 9 } phyControlGroup OBJECT-GROUP OBJECTS { linkSymmetry , linkModeOptimisation , userConfiguredMaxModulationMode , remoteMaximumTransmitPower , txColorCode , rxColorCode , automaticTxPowerControl , remoteRxTargetPower } STATUS current DESCRIPTION "The phyControl object group." ::= { ptpGroups 10 } phyStatusGroup OBJECT-GROUP OBJECTS { receivePower , vectorError , transmitPower , range , linkLoss , receiveChannel , transmitChannel , receiveModulationMode , transmitModulationMode , receiveFreqMHz , transmitFreqMHz , signalStrengthRatio , receiveFreqKHz , transmitFreqKHz , searchState , rawReceivePower } STATUS current DESCRIPTION "The phyStatus object group." ::= { ptpGroups 12 } alarmsGroup OBJECT-GROUP OBJECTS { unitOutOfCalibration , incompatibleRegionCodes , noWirelessChannelAvailable , wirelessLinkDisabledWarning , dataPortDisabledWarning , dataPortFiberStatus , dataPortConfigurationMismatch , incompatibleMasterAndSlave , tDDSynchronizationStatus , managementPortDisabledWarning , tDDSynchronizationAlarm , linkModeOptimizationMismatch , managementPortConfigurationMismatch , secureModeAlarm , ethernetBridgingStatusAlarm } STATUS current DESCRIPTION "The alarms object group." ::= { ptpGroups 13 } smtpGroup OBJECT-GROUP OBJECTS { sMTPEmailAlert , sMTPServerIPAddress , sMTPServerPortNumber , sMTPSourceEmailAddress , sMTPDestinationEmailAddress , sMTPEnabledMessages , sMTPServerInternetAddressType , sMTPServerInternetAddress } STATUS current DESCRIPTION "The smtp object group." ::= { ptpGroups 15 } snmpControlGroup OBJECT-GROUP OBJECTS { sNMPPortNumber , sNMPCommunityString , sNMPTrapTableNumber , sNMPTrapVersion , sNMPEnabledTraps , enabledDiagnosticAlarms , sNMPSendAllTrapsAtStartup , sNMPTrapIPAddress , sNMPTrapPortNumber , sNMPTrapInternetAddressType , sNMPTrapInternetAddress , sNMPTrapReceiverEnabled } STATUS current DESCRIPTION "The snmpControl object group." ::= { ptpGroups 16 } sntpGroup OBJECT-GROUP OBJECTS { sNTPState , sNTPPollInterval , sNTPSync , sNTPLastSync , systemClock , timeZone , daylightSaving , sNTPPrimaryServer , sNTPPrimaryServerDeadTime , sNTPServerRetries , sNTPServerTimeout , sNTPServerTableNumber , sNTPServerIPAddress , sNTPServerPortNumber , sNTPServerStatus , sNTPServerInternetAddressType , sNTPServerInternetAddress } STATUS current DESCRIPTION "The sntp object group." ::= { ptpGroups 17 } resetGroup OBJECT-GROUP OBJECTS { systemReset } STATUS current DESCRIPTION "The reset object group." ::= { ptpGroups 18 } versionsGroup OBJECT-GROUP OBJECTS { softwareVersion , hardwareVersion , secondarySoftwareVersion , bootVersion } STATUS current DESCRIPTION "The versions object group." ::= { ptpGroups 19 } pubStatsGroup OBJECT-GROUP OBJECTS { receiveDataRate , transmitDataRate , aggregateDataRate , wirelessLinkAvailability , wirelessLinkStatus , byteErrorRatio , receiveModulationModeDetail , ethernetBridgingAvailability } STATUS current DESCRIPTION "The pubStats object group." ::= { ptpGroups 20 } encryptionGroup OBJECT-GROUP OBJECTS { encryptionAlgorithm } STATUS current DESCRIPTION "The encryption object group." ::= { ptpGroups 22 } tDDControlGroup OBJECT-GROUP OBJECTS { tDDSynchronizationMode } STATUS current DESCRIPTION "The tDDControl object group." ::= { ptpGroups 23 } aAAControlGroup OBJECT-GROUP OBJECTS { userTableNumber , userName , userRole , userEnabled , userPassword } STATUS current DESCRIPTION "The aAAControl object group." ::= { ptpGroups 25 } syslogControlGroup OBJECT-GROUP OBJECTS { syslogClient , syslogState } STATUS current DESCRIPTION "The syslogControl object group." ::= { ptpGroups 24 } supplementaryGroup OBJECT-GROUP OBJECTS { longitude , latitude , altitude } STATUS current DESCRIPTION "The supplementary object group." ::= { ptpGroups 96 } notificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { channelChangeTrap , dfsImpulsiveInterferenceTrap , dataPortStatusTrap , telecomsChannelAStatusTrap , telecomsChannelBStatusTrap , channelALoopbackTrap , channelBLoopbackTrap , regionCodeTrap , installStatusTrap , installArmStateTrap , unitOutOfCalibrationTrap , incompatibleRegionCodesTrap , noWirelessChannelAvailableTrap , wirelessLinkDisabledWarningTrap , dataPortDisabledWarningTrap , dataPortFiberStatusTrap , dataPortConfigurationMismatchTrap , incompatibleMasterAndSlaveTrap , sNTPSyncTrap , tDDSynchronizationAlarmTrap , managementPortStatusTrap , managementPortDisabledWarningTrap , linkModeOptimizationMismatchTrap , managementPortConfigurationMismatchTrap , syslogStateTrap , syslogLocalNearlyFullTrap , syslogLocalWrappedTrap , syslogClientTrap , secureModeAlarmTrap , ethernetBridgingStatusAlarmTrap } STATUS current DESCRIPTION "The notifications group." ::= { ptpGroups 99 } DfsTableEntry ::= SEQUENCE { dfsTableIndex INTEGER , dfsMeans Integer32 , dfsNineNinePointNinePercentiles Integer32 , dfsPeaks Integer32 } dfsTable OBJECT-TYPE SYNTAX SEQUENCE OF DfsTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " A table storing a snapshot of various DFS measurements for each channel" ::= { dfs 2 } dfsTableEntry OBJECT-TYPE SYNTAX DfsTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table DfsTable" INDEX { dfsTableIndex } ::= { dfsTable 1 } EthernetPriorityTableEntry ::= SEQUENCE { ethernetPriorityTableIndex INTEGER , ethernetPriorityQueueMapping INTEGER } ethernetPriorityTable OBJECT-TYPE SYNTAX SEQUENCE OF EthernetPriorityTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " A priority queue mapping table. This is a list of packet queues indexed by Ethernet priority." ::= { ethernet 15 } ethernetPriorityTableEntry OBJECT-TYPE SYNTAX EthernetPriorityTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table EthernetPriorityTable" INDEX { ethernetPriorityTableIndex } ::= { ethernetPriorityTable 1 } L2CPPriorityTableEntry ::= SEQUENCE { l2CPPriorityTableIndex INTEGER , l2CPPriorityQueueMapping INTEGER } l2CPPriorityTable OBJECT-TYPE SYNTAX SEQUENCE OF L2CPPriorityTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " A priority queue mapping table. This is a list of packet queues indexed by L2CP priority." ::= { ethernet 17 } l2CPPriorityTableEntry OBJECT-TYPE SYNTAX L2CPPriorityTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table L2CPPriorityTable" INDEX { l2CPPriorityTableIndex } ::= { l2CPPriorityTable 1 } IPDSCPPriorityTableEntry ::= SEQUENCE { iPDSCPPriorityTableIndex INTEGER , iPDSCPPriorityQueueMapping INTEGER } iPDSCPPriorityTable OBJECT-TYPE SYNTAX SEQUENCE OF IPDSCPPriorityTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " A priority queue mapping table. This is a list of packet queues indexed by L3 IP DSCP priority." ::= { ethernet 19 } iPDSCPPriorityTableEntry OBJECT-TYPE SYNTAX IPDSCPPriorityTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table IPDSCPPriorityTable" INDEX { iPDSCPPriorityTableIndex } ::= { iPDSCPPriorityTable 1 } MPLSTCPriorityTableEntry ::= SEQUENCE { mPLSTCPriorityTableIndex INTEGER , mPLSTCPriorityQueueMapping INTEGER } mPLSTCPriorityTable OBJECT-TYPE SYNTAX SEQUENCE OF MPLSTCPriorityTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " A priority queue mapping table. This is a list of priority queues indexed by MPLS TC priority." ::= { ethernet 21 } mPLSTCPriorityTableEntry OBJECT-TYPE SYNTAX MPLSTCPriorityTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table MPLSTCPriorityTable" INDEX { mPLSTCPriorityTableIndex } ::= { mPLSTCPriorityTable 1 } SNMPTrapTableEntry ::= SEQUENCE { sNMPTrapTableIndex INTEGER , sNMPTrapIPAddress IpAddress , sNMPTrapPortNumber INTEGER , sNMPTrapInternetAddressType INTEGER , sNMPTrapInternetAddress InetAddress , sNMPTrapReceiverEnabled INTEGER } sNMPTrapTable OBJECT-TYPE SYNTAX SEQUENCE OF SNMPTrapTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " SNMP trap configuration table." ::= { snmpControl 4 } sNMPTrapTableEntry OBJECT-TYPE SYNTAX SNMPTrapTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table SNMPTrapTable" INDEX { sNMPTrapTableIndex } ::= { sNMPTrapTable 1 } SNTPServerTableEntry ::= SEQUENCE { sNTPServerTableIndex INTEGER , sNTPServerIPAddress IpAddress , sNTPServerPortNumber INTEGER , sNTPServerStatus DisplayString , sNTPServerInternetAddressType INTEGER , sNTPServerInternetAddress InetAddress } sNTPServerTable OBJECT-TYPE SYNTAX SEQUENCE OF SNTPServerTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { sntp 15 } sNTPServerTableEntry OBJECT-TYPE SYNTAX SNTPServerTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table SNTPServerTable" INDEX { sNTPServerTableIndex } ::= { sNTPServerTable 1 } UserTableEntry ::= SEQUENCE { userTableIndex INTEGER , userName OCTET STRING , userRole INTEGER , userEnabled INTEGER , userPassword OCTET STRING } userTable OBJECT-TYPE SYNTAX SEQUENCE OF UserTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The User Table Control group contains objects specifically for user account management." ::= { aAAControl 2 } userTableEntry OBJECT-TYPE SYNTAX UserTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table UserTable" INDEX { userTableIndex } ::= { userTable 1 } -- Dfs group attribute definitions -- dfsTableNumber OBJECT-TYPE SYNTAX INTEGER (1..63) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the dfsTable" ::= { dfs 1 } -- DfsTable group attribute definitions -- dfsTableIndex OBJECT-TYPE SYNTAX INTEGER (1..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "used to index values in the dfsTable." ::= { dfsTableEntry 1 } dfsMeans OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Snapshot of DFS means" ::= { dfsTableEntry 2 } dfsNineNinePointNinePercentiles OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Snapshot of DFS 99.9 percentiles" ::= { dfsTableEntry 3 } dfsPeaks OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Snapshot of DFS peaks" ::= { dfsTableEntry 4 } -- Bridge group attribute definitions -- localPacketFiltering OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "When Local Packet Filtering is Enabled, the bridge learns the source MAC addresses of devices transmitting Ethernet packets on the local Ethernet network, and only bridges packets to the remote unit if the destination MAC address has not been learnt as a 'local' device. When Local Packet Filtering is Disabled then the bridge does not learn the source MAC addresses of devices transmitting Ethernet packets on the local Ethernet network, and bridges ALL Ethernet packets received to the remote unit. Local Packet Filtering should be enabled if no external routing hardware is present" ::= { bridge 1 } -- Configuration group attribute definitions -- iPv4Address OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Internet protocol (IPv4) address. This address is used by the family of Internet protocols to uniquely identify the unit on a network. NB: A system reboot is required to activate changes to this attribute." ::= { configuration 1 } subnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "A subnet allows the flow of network traffic between hosts to be segregated based on a network configuration. By organizing hosts into logical groups, subnetting can improve network security and performance. NB: A system reboot is required to activate changes to this attribute" ::= { configuration 2 } gatewayIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IPv4 address of a computer on the current network that is currently acting as an IPv4 network gateway. A gateway acts as an entrance / exit to packets from / to other networks. NB: A system reboot is required to activate changes to this attribute" ::= { configuration 3 } targetMACAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) MAX-ACCESS read-only STATUS current DESCRIPTION "MAC address of the PTP wireless unit forming the other end of the PTP link" ::= { configuration 4 } masterSlaveMode OBJECT-TYPE SYNTAX INTEGER { master(0), slave(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The PTP wireless link operates using a master and slave relationship" ::= { configuration 5 } maximumTransmitPower OBJECT-TYPE SYNTAX INTEGER (-15..27) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum transmit power the wireless unit is permitted to use when establishing and maintaining the wireless link" ::= { configuration 6 } antennaGain OBJECT-TYPE SYNTAX INTEGER (0..610) MAX-ACCESS read-write STATUS current DESCRIPTION "Antenna Gain. Expressed in 10ths of dBi. NB: This attribute is ignored for variants with an integral antenna." ::= { configuration 7 } cableLoss OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Loss in the cable between the ODU and the antenna. Expressed in 10ths of dB. NB: This attribute is ignored for variants with an integral antenna." ::= { configuration 8 } eIRP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Effective Isotropic Radiated Power (EIRP) describes the strength of the radio signal leaving the wireless unit. Expressed in 10ths of dBm" ::= { configuration 9 } ethernetCappedMaxWirelessSpeed OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet frames will be discarded in the ODU if the data rate over the wireless link exceeds the Ethernet link speed at the local or remote Data port. The Ethernet Capped Max Wireless Speed control limits the wireless data rate based on the local and remote Ethernet link speed. Set this control to Enabled if either ODU is connected to an Ethernet link operating at less than 1000 Mbps. NB: This attribute is automatically disabled when the installation agent is armed. To disarm the installation agent use the installation wizard." ::= { configuration 10 } channelBandwidth OBJECT-TYPE SYNTAX INTEGER { bw30MHz(0), bw15MHz(1), bw10MHz(2), bw5MHz(3), bw20MHz(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This control sets the bandwidth of the transmit and receive radio channels" ::= { configuration 11 } remoteIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP Address of the peer wireless unit" ::= { configuration 12 } linkName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "Name of the PTP link allocated by the System Administrator. Used to establish a connection with the correct PTP wireless unit at the other end of the link. NOTE: The link name MUST be the same at both ends of the PTP link." ::= { configuration 14 } siteName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "This field contains a user-provided description of the site name together with any additional notes" ::= { configuration 15 } accessMethod OBJECT-TYPE SYNTAX INTEGER { linkAccess(0), linkNameAccess(1), groupAccess(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "ODUs must be configured in pairs before a link can be established. The Access Method attribute determines how the paired ODUs will recognise each other. For the Link Access method, each ODU must be configured with Target MAC Address equal to the MAC Address of the other unit. For the Link Name Access method, both units must be configured with the same Link Name. For the Group Access method, both units must be configured with the same Group ID." ::= { configuration 16 } groupID OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "When Access Method is set to Group Access, the Group ID identifies all the units belonging to the same group" ::= { configuration 17 } iPv6Address OBJECT-TYPE SYNTAX DisplayString (SIZE(0..39)) MAX-ACCESS read-write STATUS current DESCRIPTION "Internet protocol (IPv6) address. This address is used by the family of Internet protocols to uniquely identify the unit on a network. NB: A system reboot is required to activate changes to this attribute." ::= { configuration 18 } iPVersion OBJECT-TYPE SYNTAX INTEGER { iPv4(0), iPv6(1), dualIPv4andIPv6(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "IP protocol selection. Choice of IPv4, IPv6 or Dual." ::= { configuration 20 } iPv6AutoConfiguredLinkLocalAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..39)) MAX-ACCESS read-only STATUS current DESCRIPTION "The auto configured link local IPv6 address" ::= { configuration 21 } iPv6PrefixLength OBJECT-TYPE SYNTAX INTEGER (0..128) MAX-ACCESS read-write STATUS current DESCRIPTION "IPv6 prefix length" ::= { configuration 22 } iPv6GatewayAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..39)) MAX-ACCESS read-write STATUS current DESCRIPTION "The IPv6 address of a computer on the current network that is currently acting as an IPv6 network gateway. A gateway acts as an entrance / exit to packets from / to other networks. Note that it is usual to use the link-local address of the gateway. NB: A system reboot is required to activate changes to this attribute" ::= { configuration 23 } remoteInternetAddressType OBJECT-TYPE SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), unknown6(5), unknown7(6), unknown8(7), unknown9(8), unknown10(9), unknown11(10), unknown12(11), unknown13(12), unknown14(13), unknown15(14), unknown16(15), dns(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of Internet address specified by the associated remoteInternetAddressType." ::= { configuration 24 } remoteInternetAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-only STATUS current DESCRIPTION "INET address used to identify the peer wireless unit" ::= { configuration 25 } -- Ethernet group attribute definitions -- dataPortAutoNegotiation OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls whether the local Ethernet interface configuration is automatically negotiated or forced. Do not use a forced setting together with auto negotiation at the Ethernet link partner. If you want to run your Ethernet link at a fixed speed and duplex then you would normally leave auto negotiation enabled and only enable the single Auto Neg Advertisement option that you want the link to run in - FORCING ETHERNET CONFIGURATION IS A LAST RESORT WHICH SHOULD ONLY BE PERFORMED IF YOU ARE HAVING PROBLEMS WITH AUTO NEGOTIATION - AND YOU MUST ENSURE THAT YOU CONFIGURE BOTH THIS UNIT AND THE ETHERNET LINK PARTNER TO WHICH IT IS CONNECTED IDENTICALLY (THE LINK PARTNER MUST NOT HAVE AUTO NEGOTIATION ENABLED EITHER, OTHERWISE A DUPLEX MISMATCH WILL OCCUR). NB: The new setting will only take effect after a system reboot." ::= { ethernet 1 } dataPortAutoNegAdvertisement OBJECT-TYPE SYNTAX BITS { negInvalid(2), neg10MbpsHalfDuplex(3), neg10MbpsFullDuplex(4), neg100MbpsHalfDuplex(5), neg100MbpsFullDuplex(6), neg1000MbpsFullDuplex(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This sets the different Ethernet configurations that will be advertised during auto negotiation. Note the new setting will only take effect after a system reboot. WARNING: Duplex mismatch may result if both ends of the Ethernet link do not have the same settings. Do not auto negotiation together with a fixed setting at the Ethernet link partner. WARNING: Make sure that you select option(s) that you know your connected equipment can cater for!" ::= { ethernet 2 } dataPortAutoMdix OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This enables/disables the Auto MDI/MDIX capability. NB: The new setting will only take effect after a system reboot" ::= { ethernet 3 } dataPortStatus OBJECT-TYPE SYNTAX INTEGER { down(0), copperLinkUp(1), fiberLinkUp(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of the Ethernet link. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ethernet 4 } dataPortSpeedAndDuplex OBJECT-TYPE SYNTAX INTEGER { speed1000MbpsFullDuplex(0), speed100MbpsFullDuplex(1), speed100MbpsHalfDuplex(2), speed10MbpsFullDuplex(3), speed10MbpsHalfDuplex(4), speedUnknown6(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current speed and duplex of the Ethernet link" ::= { ethernet 5 } dataPortWirelessDownAlert OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "When enabled, this causes the Ethernet link to be dropped briefly when the wireless link drops. This is so that spanning tree algorithms can quickly detect that there is a problem." ::= { ethernet 6 } useVLANForManagementInterfaces OBJECT-TYPE SYNTAX INTEGER { noVLANTagging(0), iEEE8021QTaggedCTagType8100(1), iEEE8021adTaggedSTagorBTagType88a8(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls whether the management interfaces (WWW/SNMP/SMTP/SNTP) use VLAN tags or not. NB: The new setting will only take effect after a system reboot" ::= { ethernet 7 } vLANManagementPriority OBJECT-TYPE SYNTAX INTEGER { p0(0), p1(1), p2(2), p3(3), p4(4), p5(5), p6(6), p7(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This VLAN Priority (0-7) will be included in packets generated by the management interfaces. NB: The new setting will only take effect after a system reboot" ::= { ethernet 8 } vLANManagementVID OBJECT-TYPE SYNTAX INTEGER (0..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "This VLAN VID (0-4094) will be included in packets generated by the management interfaces. Note the new setting will only take effect after a system reboot" ::= { ethernet 11 } managementPortStatus OBJECT-TYPE SYNTAX INTEGER { down(0), copperLinkUp(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of the out-of-band management link. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ethernet 12 } managementPortSpeedAndDuplex OBJECT-TYPE SYNTAX INTEGER { speed100MbpsFullDuplex(1), speed100MbpsHalfDuplex(2), speed10MbpsFullDuplex(3), speed10MbpsHalfDuplex(4), speedUnknown6(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current speed and duplex of the out-of-band management link" ::= { ethernet 13 } ethernetPriorityTableNumber OBJECT-TYPE SYNTAX INTEGER (9) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the vLANPriorityTable." ::= { ethernet 14 } l2CPPriorityTableNumber OBJECT-TYPE SYNTAX INTEGER (5) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the l2CPPriorityTable." ::= { ethernet 16 } iPDSCPPriorityTableNumber OBJECT-TYPE SYNTAX INTEGER (64) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the iPDSCPPriorityTable." ::= { ethernet 18 } mPLSTCPriorityTableNumber OBJECT-TYPE SYNTAX INTEGER (8) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the mPLSTCPriorityTable." ::= { ethernet 20 } managementMode OBJECT-TYPE SYNTAX INTEGER { outofBandLocal(0), outofBand(1), inBand(2), inBandLocal(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Out-of-Band Management (only available on certain hardware models): End-to-end out-of-band mode in which the management agent can be reached from the management port at the local ODU and (assuming that the wireless link is established) the management port at the remote ODU. Out-of-Band Local Management (only available on certain hardware models): Similar to the standard Out-of-Band mode, except that management frames are not forwarded over the wireless link. In-Band Management (default): The management agent can be reached from the data port at the local ODU and (assuming that the wireless link is established) the data port at the remote ODU. In this mode the management port is disabled. In-Band Local Management (only available when 'Use VLAN For Management Interfaces' configures a VLAN tag): Similar to the standard In-Band mode, except that management frames are not forwarded over the wireless link." ::= { ethernet 22 } managementPortWirelessDownAlert OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "When enabled, this causes the management link to be dropped briefly when the wireless link drops. This is so that spanning tree algorithms can quickly detect that there is a problem." ::= { ethernet 23 } qOSPriorityScheme OBJECT-TYPE SYNTAX INTEGER { ethernet(0), iPMPLS(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects classification based on fields in the Ethernet header (Layer 2) or in the Network header (Layer 3). The unit recognises two network layer protocols: IP and MPLS" ::= { ethernet 24 } unknownNetworkPriorityQueueMapping OBJECT-TYPE SYNTAX INTEGER { q0(0), q1(1), q2(2), q3(3), q4(4), q5(5), q6(6), q7(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Configures the classification of unknown network protocols to an egress queue at the wireless port. Unknown means something other than IP and MPLS" ::= { ethernet 25 } dSCPManagementPriority OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION "This Differentiated Services Code Point value will be inserted in the IP Header of all IP Datagrams transmitted by the management interfaces" ::= { ethernet 26 } ethernetBridgingStatus OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of Ethernet packet bridging over the wireless link" ::= { ethernet 27 } -- EthernetPriorityTable group attribute definitions -- ethernetPriorityTableIndex OBJECT-TYPE SYNTAX INTEGER { p0(1), p1(2), p2(3), p3(4), p4(5), p5(6), p6(7), p7(8), untagged(9) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Ethernet priority flag, used to index values in the ethernetPriorityTable" ::= { ethernetPriorityTableEntry 1 } ethernetPriorityQueueMapping OBJECT-TYPE SYNTAX INTEGER { q0(0), q1(1), q2(2), q3(3), q4(4), q5(5), q6(6), q7(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Configures the classification of this Ethernet priority (also known as IEEE 802.1p value) to an egress queue at the wireless port" ::= { ethernetPriorityTableEntry 2 } -- L2CPPriorityTable group attribute definitions -- l2CPPriorityTableIndex OBJECT-TYPE SYNTAX INTEGER { bridge(1), mRP(2), cFM(3), rAPS(4), eAPS(5) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "L2CP priority flag, used to index values in the l2CPPriorityTable" ::= { l2CPPriorityTableEntry 1 } l2CPPriorityQueueMapping OBJECT-TYPE SYNTAX INTEGER { q0(0), q1(1), q2(2), q3(3), q4(4), q5(5), q6(6), q7(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Configures the classification of this layer two control protocol (L2CP) to an egress queue at the wireless port" ::= { l2CPPriorityTableEntry 2 } -- IPDSCPPriorityTable group attribute definitions -- iPDSCPPriorityTableIndex OBJECT-TYPE SYNTAX INTEGER (1..64) MAX-ACCESS not-accessible STATUS current DESCRIPTION "IP DSCP priority flag, used to index values in the iPDSCPPriorityTable" ::= { iPDSCPPriorityTableEntry 1 } iPDSCPPriorityQueueMapping OBJECT-TYPE SYNTAX INTEGER { q0(0), q1(1), q2(2), q3(3), q4(4), q5(5), q6(6), q7(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Configures the classification of this IP differentiated services code point (DSCP) value to an egress queue at the wireless port" ::= { iPDSCPPriorityTableEntry 2 } -- MPLSTCPriorityTable group attribute definitions -- mPLSTCPriorityTableIndex OBJECT-TYPE SYNTAX INTEGER (1..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION "MPLS TC priority flag, used to index values in the mPLSTCPriorityTable" ::= { mPLSTCPriorityTableEntry 1 } mPLSTCPriorityQueueMapping OBJECT-TYPE SYNTAX INTEGER { q0(0), q1(1), q2(2), q3(3), q4(4), q5(5), q6(6), q7(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Configures the classification of this MPLS traffic class (the field formerly known as EXP) to an egress queue at the wireless port" ::= { mPLSTCPriorityTableEntry 2 } -- Telecom group attribute definitions -- telecomsInterface OBJECT-TYPE SYNTAX INTEGER { none(0), e1(1), t1(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The line interface type. If this is set to 'None' then the telecoms interfaces are disabled, and the telecom group attributes will be ignored." ::= { telecom 1 } telecomsChannelAStatus OBJECT-TYPE SYNTAX INTEGER { disabled(0), noSignalLocal(1), noSignalRemote(2), noSignalLocalandRemote(3), up(4), remoteTiming(5), noSignalLocalandRemoteTiming(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of telecoms channel A. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { telecom 2 } telecomsChannelBStatus OBJECT-TYPE SYNTAX INTEGER { disabled(0), noSignalLocal(1), noSignalRemote(2), noSignalLocalandRemote(3), up(4), remoteTiming(5), noSignalLocalandRemoteTiming(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of telecoms channel B. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { telecom 3 } channelALineCode OBJECT-TYPE SYNTAX INTEGER { aMI(0), b8ZSHDB3(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The line code setting of the telecoms interface. This must match the setting of the device connected to this interface" ::= { telecom 4 } channelBLineCode OBJECT-TYPE SYNTAX INTEGER { aMI(0), b8ZSHDB3(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The line code setting of the telecoms interface. This must match the setting of the device connected to this interface" ::= { telecom 5 } channelACableLength OBJECT-TYPE SYNTAX INTEGER { feet133(0), feet266(1), feet399(2), feet533(3), feet655(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The length of the cable connected to the telecoms interface, measured in feet" ::= { telecom 6 } channelBCableLength OBJECT-TYPE SYNTAX INTEGER { feet133(0), feet266(1), feet399(2), feet533(3), feet655(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The length of the cable connected to the telecoms interface, measured in feet" ::= { telecom 7 } channelALoopback OBJECT-TYPE SYNTAX INTEGER { none(0), copper(1), wireless(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The loopback status of telecoms channel A. This is intended for installation testing and should be set to 'None' for normal operation. The wire connections to a unit can be tested by applying a 'Copper' loopback to the local unit. The wireless connection to the remote unit can be tested by applying a 'Wireless' loopback to the remote unit with no loopback on the local unit. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { telecom 8 } channelBLoopback OBJECT-TYPE SYNTAX INTEGER { none(0), copper(1), wireless(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The loopback status of telecoms channel B. This is intended for installation testing and should be set to 'None' for normal operation. The wire connections to a unit can be tested by applying a 'Copper' loopback to the local unit. The wireless connection to the remote unit can be tested by applying a 'Wireless' loopback to the remote unit with no loopback on the local unit. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { telecom 9 } telecomsChannelSelection OBJECT-TYPE SYNTAX INTEGER { channelAOnly(0), channelsAandB(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates which telecoms channels have been enabled. If only Channel A has been enabled, then the Channel B attributes will be ignored." ::= { telecom 10 } -- Licence group attribute definitions -- regionCode OBJECT-TYPE SYNTAX INTEGER { regionCodeInvalid(0), regionCode1(1), regionCode2(2), regionCode3(3), regionCode4(4), regionCode5(5), regionCode6(6), regionCode7(7), regionCode8(8), regionCode9(9), regionCode10(10), regionCode11(11), regionCode12(12), regionCode13(13), regionCode14(14), regionCode15(15), regionCode16(16), regionCode17(17), regionCode18(18), regionCode19(19), regionCode20(20), regionCode21(21), regionCode22(22), regionCode23(23), regionCode24(24), regionCode25(25), regionCode26(26), regionCode27(27), regionCode28(28), regionCode29(29), regionCode30(30), regionCode31(31) } MAX-ACCESS read-only STATUS current DESCRIPTION "The region code prohibits the wireless unit from operating outside the regulated limits. An invalid region code indicates a corrupted license key. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { licence 1 } productVariant OBJECT-TYPE SYNTAX INTEGER { pTPxx400Full(0), pTPxx400Deprecated1(1), pTPxx400Deprecated2(2), pTPxx400Lite(3), spare1(4), pTPxx300(5), spare2(6), spare3(7), pTPxx500FullDeprecated(8), pTPxx500LiteDeprecated(9), pTPxx500(10), pTPxx600Lite(11), pTPxx600Full(12), spare5(13), spare6(14), pTP800(15) } MAX-ACCESS read-only STATUS current DESCRIPTION "The product variant" ::= { licence 2 } productName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the product variant" ::= { licence 3 } ethernetFiberSupport OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet fiber support availability on this wireless unit" ::= { licence 4 } frequencyVariant OBJECT-TYPE SYNTAX INTEGER { freq5800MHz(0), freq5400MHz(1), freq4900MHz(2), freq2500MHz(3), freq5800MHz2(4), freq5400MHz2(5), freq4500MHz(6), freq5900MHz(7), freq5200MHz(8), freq5100MHz(9), freq4800MHz(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "Frequency variant of the wireless unit" ::= { licence 5 } bandwidthVariant OBJECT-TYPE SYNTAX INTEGER { bw30MHz(0), bw15MHz(1), bw10MHz(2), bw5MHz(3), bw20MHz(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Bandwidth variant of the wireless unit" ::= { licence 6 } constantPowerSpectralDensity OBJECT-TYPE SYNTAX INTEGER { constant(0), fullPower(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Constant power spectral density mode control" ::= { licence 7 } sNMPv3Enable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "SNMPv3 availability control" ::= { licence 9 } hAZLOCConfiguration OBJECT-TYPE SYNTAX INTEGER { nonHAZLOCUnit(0), gasGroupA(1), gasGroupB(2), gasGroupC(3), gasGroupD(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The HAZLOC/ATEX Configuration of this unit. The Gas Group is configured by the license key." ::= { licence 10 } securityLevel OBJECT-TYPE SYNTAX INTEGER { normal(0), fIPS(1), uCAPL(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum configurable security level" ::= { licence 11 } -- Management group attribute definitions -- targetRange OBJECT-TYPE SYNTAX INTEGER (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "Initial target range used in installation +/-1, expressed in tenths of a kilometer. When Auto-Ranging this must be set to 0" ::= { management 1 } rangingMode OBJECT-TYPE SYNTAX INTEGER { auto0to40km(0), auto0to100km(1), auto0to200km(2), targetRange(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of ranging to use during installation, either Auto-Ranging or use a selectable Target Range" ::= { management 2 } installStatus OBJECT-TYPE SYNTAX INTEGER { ok(0), wrongPeer(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "A non-zero value indicates that signalling was received with the wrong MAC address or a mismatched link name. NB: It is very unusual to detect this, because units with mis-configured Target MAC Address will normally fail to establish a wireless link. However, rare circumstances may establish a partial wireless link and detect this situation. NB: A non-zero value on start-up, or a change of value during operation, may generate an SNMP trap and/or SMTP email alert" ::= { management 3 } installArmState OBJECT-TYPE SYNTAX INTEGER { disarmed(0), armed(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if the unit is being installed. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { management 4 } tFTPServerIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP address of the TFTP Server from which the TFTP Software Upgrade File Name will be retrieved" ::= { management 5 } tFTPServerPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The port number of the TFTP Server from which the TFTP Software Upgrade File Name will be retrieved" ::= { management 6 } tFTPSoftwareUpgradeFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..127)) MAX-ACCESS read-write STATUS current DESCRIPTION "Filename of the Software Upgrade to be loaded from the TFTP Server" ::= { management 7 } tFTPStartSoftwareUpgrade OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Write '1' to this attribute to start the TFTP software upgrade process. The attribute will be reset to 0 when the upgrade process has finished. Continuing with the software upgrade will cause spectrum management (DSO) channel metrics collection to stop. The wireless unit will no longer search for the optimal operational radio channel. The performance of this wireless link may deterioate over time. If operating in a region where RADAR detection is mandatory you must complete the software upgrade and reboot the unit. Channel metrics collection will only be restarted after the wireless unit has been rebooted" ::= { management 8 } tFTPSoftwareUpgradeStatus OBJECT-TYPE SYNTAX INTEGER { idle(0), uploadinprogress(1), uploadsuccessfulprogrammingFLASH(2), upgradesuccessfulreboottorunthenewsoftwareimage(3), upgradefailed(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of the TFTP Software upgrade process" ::= { management 9 } tFTPSoftwareUpgradeStatusText OBJECT-TYPE SYNTAX DisplayString (SIZE(0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Descriptive text describing the status of the TFTP Software upgrade process, including any error details" ::= { management 10 } tFTPSoftwareUpgradeStatusAdditionalText OBJECT-TYPE SYNTAX DisplayString (SIZE(0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Any additional text describing the status of the TFTP Software upgrade process, including any error details" ::= { management 11 } hTTPAccessEnabled OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls whether or not HTTP access is enabled, i.e. if this is disabled (0) then the unit will not respond to any requests on the HTTP port. Remote management via HTTPS is not affected by this setting. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = Enabled)" ::= { management 12 } telnetAccessEnabled OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls whether or not Telnet access is enabled, i.e. if this is disabled (0) then the unit will not respond to any requests on the TELNET port. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = Disabled)" ::= { management 13 } hTTPPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This controls the port number for HTTP access. A value of zero will use the default port number. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = 80)" ::= { management 14 } hTTPSPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This controls the port number for HTTPS access. A value of zero will use the default port number. Availability of HTTPS is controlled via the License Key. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = 443)" ::= { management 15 } telnetPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This controls the port number for TELNET access. A value of zero will use the default port number. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = 23)" ::= { management 16 } hTTPSAccessEnabled OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls whether or not HTTPS access is enabled, i.e. if this is disabled (0) then the unit will not respond to any requests on the HTTPS port. Remote management via HTTP is not affected by this setting. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = Enabled)" ::= { management 17 } tFTPServerInternetAddressType OBJECT-TYPE SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), unknown6(5), unknown7(6), unknown8(7), unknown9(8), unknown10(9), unknown11(10), unknown12(11), unknown13(12), unknown14(13), unknown15(14), unknown16(15), dns(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of Internet address specified by the associated tFTPServerInternetAddress." ::= { management 18 } tFTPServerInternetAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-write STATUS current DESCRIPTION "INET address of the TFTP Server from which the TFTP Software Upgrade File Name will be retrieved" ::= { management 19 } -- PhyControl group attribute definitions -- linkSymmetry OBJECT-TYPE SYNTAX INTEGER { symmetryAdaptive(0), symmetry2to1(1), symmetry1to1(2), symmetry1to2(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Link Symmetry: in fixed symmetric mode the master spends an equal amount of time transmitting and receiving; in fixed asymmetric modes the master transmit and receive times have a fixed ratio; in adaptive mode the transmit and receive periods adjust with applied load." ::= { phyControl 1 } linkModeOptimisation OBJECT-TYPE SYNTAX INTEGER { iPTraffic(0), tDMTraffic(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Optimises the wireless link behavior for the type of traffic to be carried. In 'IP Traffic' mode, the wireless link will minimise transmission errors by automatically adapting the modulation mode. In 'TDM Traffic' mode, the wireless link will minimise transmission latency and preserve throughput by maintaining a higher modulation mode in the presence of a limited number of errors. The 'TDM Traffic' mode is recommended for E1/T1 applications and connectionless protocols." ::= { phyControl 2 } userConfiguredMaxModulationMode OBJECT-TYPE SYNTAX INTEGER { modBpsk63percent(0), modQpsk63percent(1), modQpsk87percent(2), mod16qam63percent(3), mod16qam87percent(4), mod64qam75percent(5), mod64qam92percent(6), mod256qam81percent(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum receive modulation mode controls the MAX mode used for adaptive modulation. NOTE: This attribute is automatically disabled when the installation agent is armed. To disarm the installation agent use the installation wizard" ::= { phyControl 3 } remoteMaximumTransmitPower OBJECT-TYPE SYNTAX INTEGER (-15..27) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum transmit power the remote wireless unit is permitted to use when establishing and maintaining the wireless link" ::= { phyControl 4 } txColorCode OBJECT-TYPE SYNTAX INTEGER { a(0), b(1), c(2), d(3), e(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Transmit Color Code. This attribute need only be considered when the unit is installed in a network of PTP600 units and where some of the units are operating on the same frequency. In this case, the value would normally be derived by a network planner. In all other cases, it is recommended that this attribute is left at the default value. NOTE: For the link to operate, the value of this parameter must in all cases match the value of the Rx Color Code parameter at the far end of the link." ::= { phyControl 5 } rxColorCode OBJECT-TYPE SYNTAX INTEGER { a(0), b(1), c(2), d(3), e(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Receive Color Code. This attribute need only be considered when the unit is installed in a network of PTP600 units and where some of the units are operating on the same frequency. In this case, the value would normally be derived by a network planner. In all other cases, it is recommended that this attribute is left at the default value. NOTE: For the link to operate, the value of this parameter must in all cases match the value of the Tx Color Code parameter at the far end of the link." ::= { phyControl 6 } automaticTxPowerControl OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1), enabledwithinitialestimate(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "When enabled, the transmit power of the local end is automatically adjusted to maintain a configurable target receive signal level at the remote end of the link. When set to Enable with initial estimate, the Slave estimates the optional transmit power before it responds to the Master." ::= { phyControl 8 } remoteRxTargetPower OBJECT-TYPE SYNTAX INTEGER (-600..-400) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the target receive level for the end of the link which is remote from the end being configured. When Automatic Power Control is enabled, the transmit power of the local end is automatically adjusted in order to maintain the receive signal level at the remote end within a range centered on this value" ::= { phyControl 9 } -- PhyStatus group attribute definitions -- receivePower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Receive power expressed in tenths of a dBm" ::= { phyStatus 1 } vectorError OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The vector error measurement compares the received signal's IQ modulation characteristics to an ideal signal to determine the composite error vector magnitude. The value represented by this attribute is the average vector error over the previous second expressed in tenths of a dB" ::= { phyStatus 2 } transmitPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Transmit power expressed in tenths of a dBm" ::= { phyStatus 3 } range OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Distance between the two peer wireless units expressed in tenths of a kilometer" ::= { phyStatus 4 } linkLoss OBJECT-TYPE SYNTAX INTEGER (-500..500) MAX-ACCESS read-only STATUS current DESCRIPTION "The wireless link loss expressed in tenths of a dB" ::= { phyStatus 5 } receiveChannel OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION "Current active receive channel" ::= { phyStatus 6 } transmitChannel OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION "Current active transmit channel" ::= { phyStatus 7 } receiveModulationMode OBJECT-TYPE SYNTAX INTEGER { modAcquisition(0), modBpsk63percent(1), modQpsk63percentSingle(2), modTransient1(3), modQpsk87percentSingle(4), modTransient2(5), mod16qam63percentSingleA(6), modTransient3(7), mod16qam87percentSingle(8), modTransient4(9), mod64qam75percentSingle(10), modTransient5(11), mod64qam92percentSingle(12), modTransient6(13), mod256qam81percentSingle(14), mod16qam63percentSingleB(15), mod16qam63percentDual(16), modTransient7(17), mod16qam87percentDual(18), modTransient8(19), mod64qam75percentDual(20), modTransient9(21), mod64qam92percentDual(22), modTransient10(23), mod256qam81percentDual(24) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current active receive modulation mode" ::= { phyStatus 8 } transmitModulationMode OBJECT-TYPE SYNTAX INTEGER { modAcquisition(0), modBpsk63percent(1), modQpsk63percentSingle(2), modTransient1(3), modQpsk87percentSingle(4), modTransient2(5), mod16qam63percentSingleA(6), modTransient3(7), mod16qam87percentSingle(8), modTransient4(9), mod64qam75percentSingle(10), modTransient5(11), mod64qam92percentSingle(12), modTransient6(13), mod256qam81percentSingle(14), mod16qam63percentSingleB(15), mod16qam63percentDual(16), modTransient7(17), mod16qam87percentDual(18), modTransient8(19), mod64qam75percentDual(20), modTransient9(21), mod64qam92percentDual(22), modTransient10(23), mod256qam81percentDual(24) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current active transmit modulation mode" ::= { phyStatus 9 } receiveFreqMHz OBJECT-TYPE SYNTAX INTEGER (0..5925) MAX-ACCESS read-only STATUS current DESCRIPTION "Current receive frequency expressed in integer MHz" ::= { phyStatus 11 } transmitFreqMHz OBJECT-TYPE SYNTAX INTEGER (0..5925) MAX-ACCESS read-only STATUS current DESCRIPTION "Current transmit frequency expressed in integer MHz" ::= { phyStatus 12 } signalStrengthRatio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Signal strength ratio (Vertical / Horizontal) : the number of dB larger the Vertical antenna input is than the Horizontal antenna input expressed in tenths of a dB" ::= { phyStatus 13 } receiveFreqKHz OBJECT-TYPE SYNTAX INTEGER (0..5925000) MAX-ACCESS read-only STATUS current DESCRIPTION "Current receive frequency expressed as KHz" ::= { phyStatus 14 } transmitFreqKHz OBJECT-TYPE SYNTAX INTEGER (0..5925000) MAX-ACCESS read-only STATUS current DESCRIPTION "Current transmit frequency expressed as KHz" ::= { phyStatus 15 } searchState OBJECT-TYPE SYNTAX INTEGER { registering(0), searching(1), acquiring(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Search status of the wireless modem. 'Registering' means that the modem has locked to an OFDM signal, and the wireless link is up. 'Searching' means that no wireless signal has been detected. 'Acquiring' means that a wireless signal has been detected, but the modem has not locked to an OFDM signal." ::= { phyStatus 16 } rawReceivePower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Raw receive power expressed in tenths of a dBm" ::= { phyStatus 17 } -- Alarms group attribute definitions -- unitOutOfCalibration OBJECT-TYPE SYNTAX INTEGER { calibrated(0), outOfCalibration(1), outOfCalibrationPAsShutdown(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The unit is out of calibration" ::= { alarms 1 } incompatibleRegionCodes OBJECT-TYPE SYNTAX INTEGER { ok(0), incompatibleLicenceKeys(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The master and slave units have incompatible region codes. NB: Both units must have compatible license keys" ::= { alarms 4 } noWirelessChannelAvailable OBJECT-TYPE SYNTAX INTEGER { ok(0), noWirelessChannelAvailable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Spectrum Management was unable to locate a suitable wireless channel to operate on" ::= { alarms 5 } wirelessLinkDisabledWarning OBJECT-TYPE SYNTAX INTEGER { ok(0), disabledBySNMPifAdminStatus(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The SNMP ifAdminStatus of the wireless interface has disabled wireless traffic" ::= { alarms 6 } dataPortDisabledWarning OBJECT-TYPE SYNTAX INTEGER { ok(0), disabledBySNMPifAdminStatus(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The SNMP ifAdminStatus of the Ethernet interface has disabled Ethernet traffic" ::= { alarms 7 } dataPortFiberStatus OBJECT-TYPE SYNTAX INTEGER { ok(0), installedFiberNotLicensed(1), fiberLinkNotEstablishedButLOSNotDetected(2), fiberLinkNotEstablishedAndLOSDetected(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "If the fiber link is not OK, there are three possible causes: Either the fiber link has been installed but disabled (because the license key does not include fiber support), the link could not be established even though no LOS was detected (i.e. an optical carrier was detected, which could be due to a broken TX fiber, or because the link is disabled at the fiber link partner), or the link could not be established and LOS is detected (i.e. no optical carrier is detected). NB: a change of status may generate an SNMP trap and/or SMTP email alert" ::= { alarms 8 } dataPortConfigurationMismatch OBJECT-TYPE SYNTAX INTEGER { noError(0), mismatchDetected(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The detection of Ethernet fragments (runt packets) when the link is in full duplex is an indication of an auto-negotiation or forced configuration mismatch" ::= { alarms 9 } incompatibleMasterAndSlave OBJECT-TYPE SYNTAX INTEGER { ok(0), incompatibleProductVariants(1), differentSoftwareVersionsRunning(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "A non-zero value indicates that the master and slave ends of a link are different hardware products, or have different software versions. NB: It is very unusual to detect this, because incompatible units will normally fail to establish a wireless link. However, some combinations may establish a partial wireless link and detect this situation. NB: A non-zero value may generate an SNMP trap and/or SMTP email alert" ::= { alarms 10 } tDDSynchronizationStatus OBJECT-TYPE SYNTAX INTEGER { locked(0), holdover(1), holdoverNotConnected(2), acquiringLock(3), noTimingReference(4), timingSystemNotConnected(5), initialising(6), clusterTimingMaster(7), tDDSyncNotActive(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "An alarm value (displayed in red) indicates that one of the following conditions has not been met (i) An external timing system is connected or internal timing has been configured. (ii) The timing system is providing a useable reference. (iii) The ODU is locked to this reference." ::= { alarms 11 } managementPortDisabledWarning OBJECT-TYPE SYNTAX INTEGER { ok(0), disabledBySNMPifAdminStatus(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The SNMP ifAdminStatus of the out-of-band management interface has disabled Ethernet traffic" ::= { alarms 12 } tDDSynchronizationAlarm OBJECT-TYPE SYNTAX INTEGER { ok(0), notSynchronized(1), timingSystemFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Not Synchronized indicates failure of the external timing system for a period greater than the holdover timer. TDD frame timing will have drifted, and this link may cause interference with other links in a synchronized network. Timing System Failure is an early warning, indicating that 80% of the holdover period has expired." ::= { alarms 13 } linkModeOptimizationMismatch OBJECT-TYPE SYNTAX INTEGER { ok(0), linkModeOptimizationMismatch(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The remote node of this link has been configured with a different link mode optimization" ::= { alarms 14 } managementPortConfigurationMismatch OBJECT-TYPE SYNTAX INTEGER { noError(0), mismatchDetected(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The detection of Ethernet fragments (runt packets) when the link is in full duplex is an indication of an auto-negotiation or forced configuration mismatch. This alarm is only raised if an Out-of-Band Management Mode has been configured." ::= { alarms 15 } secureModeAlarm OBJECT-TYPE SYNTAX INTEGER { secureModeIsActive(0), secureModeIsNotConfigured(1), secureModeIsConfiguredButNotActive(2), secureModeIsNotSupported(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The secure mode (e.g. FIPS, UC-APL) state of the unit. The secure mode is not configured(1) state indicates that the unit is capable of secure mode operation, and one or more of the following security materials has not been configured: Key Of Keys, Private Key, Public Certificate, DRNG Entropy Status, Wireless Encryption Key. The secure mode mode is configured but not active(2) state indicates that the unit is capable of secure mode operation, and the security material has been configured, but the configuration of interfaces is not consistent with secure mode operation. The secure mode is not supported(3) state indicates that the unit is not capable of secure mode operation. The secure mode capability requires appropriate hardware compatibility, license key and software image." ::= { alarms 16 } ethernetBridgingStatusAlarm OBJECT-TYPE SYNTAX INTEGER { ethernetBridgingEnabled(0), ethernetBridgingDisabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet traffic bridging is disabled because the wireless link is not operating at the configured Lowest Ethernet Modulation Mode" ::= { alarms 17 } -- Smtp group attribute definitions -- sMTPEmailAlert OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Simple Mail Transfer Protocol is used to send equipment alerts via email to a specified email address" ::= { smtp 1 } sMTPServerIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP address of the SMTP server" ::= { smtp 2 } sMTPServerPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Port number of the SMTP server" ::= { smtp 3 } sMTPSourceEmailAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The 'from' email address used when constructing the automatically generated e-mail message" ::= { smtp 4 } sMTPDestinationEmailAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The 'to' email address used when constructing the automatically generated e-mail message" ::= { smtp 5 } sMTPEnabledMessages OBJECT-TYPE SYNTAX BITS { telecomsChannelUpDown(1), managementPortUpDown(2), dataPortUpDown(3), enabledDiagnosticAlarms(4), dFSImpulseInterference(5), channelChange(6), wirelessLinkUpDown(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls which SMTP messages the unit will send" ::= { smtp 6 } sMTPServerInternetAddressType OBJECT-TYPE SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), unknown6(5), unknown7(6), unknown8(7), unknown9(8), unknown10(9), unknown11(10), unknown12(11), unknown13(12), unknown14(13), unknown15(14), unknown16(15), dns(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of Internet address specified by the associated sMTPServerInternetAddress." ::= { smtp 7 } sMTPServerInternetAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Internet address of the SMTP server" ::= { smtp 8 } -- SnmpControl group attribute definitions -- sNMPPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The IP port number used to access the SNMP MIB (i.e. Gets and Sets) (default = 161). NB: A system reboot is required to activate changes to this attribute" ::= { snmpControl 1 } sNMPCommunityString OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The SNMP community string. NB: A system reboot is required to activate changes to this attribute" ::= { snmpControl 2 } sNMPTrapTableNumber OBJECT-TYPE SYNTAX INTEGER (2) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the sNMPTrapTable." ::= { snmpControl 3 } sNMPTrapVersion OBJECT-TYPE SYNTAX INTEGER { v1(0), v2c(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The SNMP protocol version to use for SNMP Traps. NB: A system reboot is required to activate changes to this attribute" ::= { snmpControl 5 } sNMPEnabledTraps OBJECT-TYPE SYNTAX BITS { managementPortUpDown(0), dataPortUpDown(1), authenticationFailure(2), enabledDiagnosticAlarms(3), dFSImpulseInterference(4), channelChange(5), wirelessLinkUpDown(6), coldStart(7), telecomsChannelUpDown(15) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls which SNMP Traps the unit will send" ::= { snmpControl 6 } enabledDiagnosticAlarms OBJECT-TYPE SYNTAX BITS { incompatibleMasterAndSlave(0), incompatibleRegionCodes(1), unknown6(2), unknown5(3), unitOutOfCalibration(4), installArmState(5), installStatus(6), regionCode(7), telecomsChannelAStatus(8), dataPortFiberStatus(9), dataPortStatus(10), dataPortDisabledWarning(11), wirelessLinkDisabledWarning(12), sNTPSynchronizationFailed(13), noWirelessChannelAvailable(14), dataPortConfigurationMismatch(15), syslogDisabledWarning(16), linkModeOptimizationMismatch(17), managementPortStatus(18), managementPortDisabledWarning(19), tDDSynchronizationAlarm(20), telecomsChannelBLoopback(21), telecomsChannelALoopback(22), telecomsChannelBStatus(23), ethernetBridgingStatus(26), secureMode(27), syslogClientDisabledWarning(28), managementPortConfigurationMismatch(29), syslogLocalWrapped(30), syslogLocalNearlyFull(31) } MAX-ACCESS read-write STATUS current DESCRIPTION "Controls which individual diagnostic alarms are enabled. The unit may be configured to generate SNMP traps and/or SMTP email alerts for these enabled alarms by selecting 'Enabled Diagnostic Alarms' on the 'SNMP Enabled Traps' and/or 'SMTP Enabled Messages' attributes" ::= { snmpControl 7 } sNMPSendAllTrapsAtStartup OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether or not all the enabled traps and alarms (including cleared alarms) are reported at start-up." ::= { snmpControl 8 } -- SNMPTrapTable group attribute definitions -- sNMPTrapTableIndex OBJECT-TYPE SYNTAX INTEGER (1..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "SNMP trap value, used to index the SNMPTrapTable." ::= { sNMPTrapTableEntry 1 } sNMPTrapIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address to which all SNMP Traps are sent. NB: A system reboot is required to activate changes to this attribute." ::= { sNMPTrapTableEntry 2 } sNMPTrapPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Destination port for SNMP Traps (default=162). NB: A system reboot is required to activate changes to this attribute." ::= { sNMPTrapTableEntry 3 } sNMPTrapInternetAddressType OBJECT-TYPE SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), unknown6(5), unknown7(6), unknown8(7), unknown9(8), unknown10(9), unknown11(10), unknown12(11), unknown13(12), unknown14(13), unknown15(14), unknown16(15), dns(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of Internet address specified by the associated sNMPTrapInternetAddress." ::= { sNMPTrapTableEntry 4 } sNMPTrapInternetAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The Internet address to which all SNMP Traps are sent." ::= { sNMPTrapTableEntry 5 } sNMPTrapReceiverEnabled OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "A value of 0 disables the sending of SNMP trap to corresponding receiver. A value of 1 enables the sending of SNMP trap to corresponding receiver." ::= { sNMPTrapTableEntry 6 } -- Sntp group attribute definitions -- sNTPState OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "SNTP control state" ::= { sntp 1 } sNTPPollInterval OBJECT-TYPE SYNTAX INTEGER (60..43200) MAX-ACCESS read-write STATUS current DESCRIPTION "The SNTP server polling interval" ::= { sntp 4 } sNTPSync OBJECT-TYPE SYNTAX INTEGER { noSync(0), inSync(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "If SNTP Sync fails then check the server settings in the Remote Management page, or disable SNTP" ::= { sntp 5 } sNTPLastSync OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Last SNTP sync time" ::= { sntp 6 } systemClock OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "System clock presented as local time" ::= { sntp 7 } timeZone OBJECT-TYPE SYNTAX INTEGER { gmtMinus1200(0), gmtMinus1130(1), gmtMinus1100(2), gmtMinus1030(3), gmtMinus1000(4), gmtMinus0930(5), gmtMinus0900(6), gmtMinus0830(7), gmtMinus0800(8), gmtMinus0730(9), gmtMinus0700(10), gmtMinus0630(11), gmtMinus0600(12), gmtMinus0530(13), gmtMinus0500(14), gmtMinus0430(15), gmtMinus0400(16), gmtMinus0330(17), gmtMinus0300(18), gmtMinus0230(19), gmtMinus0200(20), gmtMinus0130(21), gmtMinus0100(22), gmtMinus0030(23), gmtZero(24), gmtPlus0030(25), gmtPlus0100(26), gmtPlus0130(27), gmtPlus0200(28), gmtPlus0230(29), gmtPlus0300(30), gmtPlus0330(31), gmtPlus0400(32), gmtPlus0430(33), gmtPlus0500(34), gmtPlus0530(35), gmtPlus0600(36), gmtPlus0630(37), gmtPlus0700(38), gmtPlus0730(39), gmtPlus0800(40), gmtPlus0830(41), gmtPlus0900(42), gmtPlus0930(43), gmtPlus1000(44), gmtPlus1030(45), gmtPlus1100(46), gmtPlus1130(47), gmtPlus1200(48), gmtPlus1230(49), gmtPlus1300(50) } MAX-ACCESS read-write STATUS current DESCRIPTION "Time zone offsets from Greenwich Mean Time (GMT)" ::= { sntp 8 } daylightSaving OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Daylight Saving Time" ::= { sntp 9 } sNTPPrimaryServer OBJECT-TYPE SYNTAX INTEGER { server1(0), server2(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the primary SNTP server, determining the order in which the servers are tried." ::= { sntp 10 } sNTPPrimaryServerDeadTime OBJECT-TYPE SYNTAX INTEGER (0..86400) MAX-ACCESS read-write STATUS current DESCRIPTION "Time (in seconds) to wait before retrying communications with an unresponsive primary SNTP server. Setting the value to 0 disables the timer." ::= { sntp 11 } sNTPServerRetries OBJECT-TYPE SYNTAX INTEGER (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of times the PTP will retry after an SNTP server fails to respond." ::= { sntp 12 } sNTPServerTimeout OBJECT-TYPE SYNTAX INTEGER (1..15) MAX-ACCESS read-write STATUS current DESCRIPTION "Time (in seconds) the PTP will wait for a response from an SNTP server." ::= { sntp 13 } sNTPServerTableNumber OBJECT-TYPE SYNTAX INTEGER (2) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the SNTPServerTable." ::= { sntp 14 } -- SNTPServerTable group attribute definitions -- sNTPServerTableIndex OBJECT-TYPE SYNTAX INTEGER (1..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index range for the SNTPServerTable." ::= { sNTPServerTableEntry 1 } sNTPServerIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of a valid SNTP server" ::= { sNTPServerTableEntry 2 } sNTPServerPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The IP port number of the SNTP server. Defaults to port 123." ::= { sNTPServerTableEntry 3 } sNTPServerStatus OBJECT-TYPE SYNTAX DisplayString (SIZE(0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Status message reflecting the result of communications with the SNTP server when last polled" ::= { sNTPServerTableEntry 4 } sNTPServerInternetAddressType OBJECT-TYPE SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), unknown6(5), unknown7(6), unknown8(7), unknown9(8), unknown10(9), unknown11(10), unknown12(11), unknown13(12), unknown14(13), unknown15(14), unknown16(15), dns(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of Internet address specified by the associated sNTPServerInternetAddress." ::= { sNTPServerTableEntry 5 } sNTPServerInternetAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The Internet address of a valid SNTP server" ::= { sNTPServerTableEntry 6 } -- Reset group attribute definitions -- systemReset OBJECT-TYPE SYNTAX INTEGER { running(0), consoleReboot(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to '1' will cause a system reboot. NB: a system reboot will apply any pending new settings held in memory" ::= { reset 1 } -- Versions group attribute definitions -- softwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Current software version" ::= { versions 1 } hardwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware platform version" ::= { versions 2 } secondarySoftwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Secondary software version, used when the primary software image is invalid or erased" ::= { versions 3 } bootVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Boot code software version" ::= { versions 4 } -- PubStats group attribute definitions -- receiveDataRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average data rate over the last one second interval (kbps)" ::= { pubStats 1 } transmitDataRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average data rate over the last one second interval (kbps)" ::= { pubStats 2 } aggregateDataRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average data rate over the last one second interval (kbps)" ::= { pubStats 3 } wirelessLinkAvailability OBJECT-TYPE SYNTAX INTEGER (0..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "Link availability calculated since the last reset of the system counters, as a percentage multiplied by 10000 to give four decimal places of precision" ::= { pubStats 4 } wirelessLinkStatus OBJECT-TYPE SYNTAX INTEGER { up(0), registering(1), searching(2), acquiring(3), radarCAC(4), initialising(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of the wireless link" ::= { pubStats 5 } byteErrorRatio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Reciprocal of the byte error ratio calculated since the last reset of the system counters" ::= { pubStats 6 } receiveModulationModeDetail OBJECT-TYPE SYNTAX INTEGER { runningAtMaximumReceiveMode(0), runningAtUserConfiguredMaxModulationMode(1), restrictedBecauseInstallationIsArmed(2), restrictedBecauseOfByteErrorsOnTheWirelessLink(3), restrictedBecauseTheLinkParametersAreUpdating(4), restrictedBecauseChannelChangeIsInProgress(5), restrictedDueToTheLowEthernetLinkSpeed(6), runningAtMaximumReceiveModeForChannelBandwidth(7), limitedByTheWirelessConditions(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The reason for the current receive modulation mode" ::= { pubStats 7 } ethernetBridgingAvailability OBJECT-TYPE SYNTAX INTEGER (0..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "Link availability bridging Ethernet traffic calculated since the last reset of the system counters, as a percentage multiplied by 10000 to give four decimal places of precision" ::= { pubStats 8 } -- Encryption group attribute definitions -- encryptionAlgorithm OBJECT-TYPE SYNTAX INTEGER { none(0), aESRijndael(1), aES256bitRijndael(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Encryption Algorithm used by the wireless link. NB: A system reboot is required to activate changes to this attribute. NB: The same Encryption Algorithm must be configured at BOTH ends of the link for it to function correctly" ::= { encryption 1 } -- TDDControl group attribute definitions -- tDDSynchronizationMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "TDD Synchronization Mode selection" ::= { tDDControl 1 } -- AAAControl group attribute definitions -- userTableNumber OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the userTable" ::= { aAAControl 1 } -- UserTable group attribute definitions -- userTableIndex OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS not-accessible STATUS current DESCRIPTION "used to index values in the userTable." ::= { userTableEntry 1 } userName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "User name which must be entered, along with the appropriate password, in order to gain access to the system." ::= { userTableEntry 2 } userRole OBJECT-TYPE SYNTAX INTEGER { readOnly(0), systemAdministrator(1), securityOfficer(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Role of the selected user. A Security Officer has access to and can modify all settings. A System Administrator has access to and can modify all non-security settings. A Read Only user can view settings, but cannot make any changes." ::= { userTableEntry 3 } userEnabled OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable / Disable the selected user" ::= { userTableEntry 4 } userPassword OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "User password, which must be entered in order to gain access to the system." ::= { userTableEntry 5 } -- SyslogControl group attribute definitions -- syslogClient OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable the syslog client" ::= { syslogControl 1 } syslogState OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The syslog service has been enabled or disabled" ::= { syslogControl 2 } -- Supplementary group attribute definitions -- longitude OBJECT-TYPE SYNTAX DisplayString (SIZE(0..19)) MAX-ACCESS read-write STATUS current DESCRIPTION "The longitude of the unit, measured in decimal degrees. This object is set by the SNMP manager and has no internal function." ::= { supplementary 1 } latitude OBJECT-TYPE SYNTAX DisplayString (SIZE(0..19)) MAX-ACCESS read-write STATUS current DESCRIPTION "The latitude of the unit, measured in decimal degrees. This object is set by the SNMP manager and has no internal function." ::= { supplementary 2 } altitude OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The altitude of the unit, measured in metres. This object is set by the SNMP manager and has no internal function." ::= { supplementary 3 } -- Enterprise NOTIFICATION definitions -- channelChangeTrap NOTIFICATION-TYPE OBJECTS { receiveChannel } STATUS current DESCRIPTION "The PTP radio has changed wireless channel. This has been caused by either i) mandatory radar avoidance, a DFS impulsive interference event will also be detected, or ii) Dynamic Spectrum Optimization, (DSO) DSO improves link performance by selecting the most appropriate transmit and receive channels with the lowest level of interference." ::= { ptpTrapPrefix 1 } dfsImpulsiveInterferenceTrap NOTIFICATION-TYPE OBJECTS { receiveChannel } STATUS current DESCRIPTION "DFS impulsive interference detected event" ::= { ptpTrapPrefix 2 } dataPortStatusTrap NOTIFICATION-TYPE OBJECTS { dataPortStatus } STATUS current DESCRIPTION "Current status of the Ethernet link. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 3 } telecomsChannelAStatusTrap NOTIFICATION-TYPE OBJECTS { telecomsChannelAStatus } STATUS current DESCRIPTION "Current status of telecoms channel A. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 4 } telecomsChannelBStatusTrap NOTIFICATION-TYPE OBJECTS { telecomsChannelBStatus } STATUS current DESCRIPTION "Current status of telecoms channel B. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 5 } channelALoopbackTrap NOTIFICATION-TYPE OBJECTS { channelALoopback } STATUS current DESCRIPTION "The loopback status of telecoms channel A. This is intended for installation testing and should be set to 'None' for normal operation. The wire connections to a unit can be tested by applying a 'Copper' loopback to the local unit. The wireless connection to the remote unit can be tested by applying a 'Wireless' loopback to the remote unit with no loopback on the local unit. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 6 } channelBLoopbackTrap NOTIFICATION-TYPE OBJECTS { channelBLoopback } STATUS current DESCRIPTION "The loopback status of telecoms channel B. This is intended for installation testing and should be set to 'None' for normal operation. The wire connections to a unit can be tested by applying a 'Copper' loopback to the local unit. The wireless connection to the remote unit can be tested by applying a 'Wireless' loopback to the remote unit with no loopback on the local unit. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 7 } regionCodeTrap NOTIFICATION-TYPE OBJECTS { regionCode } STATUS current DESCRIPTION "The region code prohibits the wireless unit from operating outside the regulated limits. An invalid region code indicates a corrupted license key. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 8 } installStatusTrap NOTIFICATION-TYPE OBJECTS { installStatus } STATUS current DESCRIPTION "A non-zero value indicates that signalling was received with the wrong MAC address or a mismatched link name. NB: It is very unusual to detect this, because units with mis-configured Target MAC Address will normally fail to establish a wireless link. However, rare circumstances may establish a partial wireless link and detect this situation. NB: A non-zero value on start-up, or a change of value during operation, may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 9 } installArmStateTrap NOTIFICATION-TYPE OBJECTS { installArmState } STATUS current DESCRIPTION "Indicates if the unit is being installed. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 10 } unitOutOfCalibrationTrap NOTIFICATION-TYPE OBJECTS { unitOutOfCalibration } STATUS current DESCRIPTION "The unit is out of calibration" ::= { ptpTrapPrefix 11 } incompatibleRegionCodesTrap NOTIFICATION-TYPE OBJECTS { incompatibleRegionCodes } STATUS current DESCRIPTION "The master and slave units have incompatible region codes. NB: Both units must have compatible license keys" ::= { ptpTrapPrefix 14 } noWirelessChannelAvailableTrap NOTIFICATION-TYPE OBJECTS { noWirelessChannelAvailable } STATUS current DESCRIPTION "Spectrum Management was unable to locate a suitable wireless channel to operate on" ::= { ptpTrapPrefix 15 } wirelessLinkDisabledWarningTrap NOTIFICATION-TYPE OBJECTS { wirelessLinkDisabledWarning } STATUS current DESCRIPTION "The SNMP ifAdminStatus of the wireless interface has disabled wireless traffic" ::= { ptpTrapPrefix 16 } dataPortDisabledWarningTrap NOTIFICATION-TYPE OBJECTS { dataPortDisabledWarning } STATUS current DESCRIPTION "The SNMP ifAdminStatus of the Ethernet interface has disabled Ethernet traffic" ::= { ptpTrapPrefix 17 } dataPortFiberStatusTrap NOTIFICATION-TYPE OBJECTS { dataPortFiberStatus } STATUS current DESCRIPTION "If the fiber link is not OK, there are three possible causes: Either the fiber link has been installed but disabled (because the license key does not include fiber support), the link could not be established even though no LOS was detected (i.e. an optical carrier was detected, which could be due to a broken TX fiber, or because the link is disabled at the fiber link partner), or the link could not be established and LOS is detected (i.e. no optical carrier is detected). NB: a change of status may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 18 } dataPortConfigurationMismatchTrap NOTIFICATION-TYPE OBJECTS { dataPortConfigurationMismatch } STATUS current DESCRIPTION "The detection of Ethernet fragments (runt packets) when the link is in full duplex is an indication of an auto-negotiation or forced configuration mismatch" ::= { ptpTrapPrefix 19 } incompatibleMasterAndSlaveTrap NOTIFICATION-TYPE OBJECTS { incompatibleMasterAndSlave } STATUS current DESCRIPTION "A non-zero value indicates that the master and slave ends of a link are different hardware products, or have different software versions. NB: It is very unusual to detect this, because incompatible units will normally fail to establish a wireless link. However, some combinations may establish a partial wireless link and detect this situation. NB: A non-zero value may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 20 } sNTPSyncTrap NOTIFICATION-TYPE OBJECTS { sNTPSync } STATUS current DESCRIPTION "If SNTP Sync fails then check the server settings in the Remote Management page, or disable SNTP" ::= { ptpTrapPrefix 21 } tDDSynchronizationAlarmTrap NOTIFICATION-TYPE OBJECTS { tDDSynchronizationAlarm } STATUS current DESCRIPTION "Not Synchronized indicates failure of the external timing system for a period greater than the holdover timer. TDD frame timing will have drifted, and this link may cause interference with other links in a synchronized network. Timing System Failure is an early warning, indicating that 80% of the holdover period has expired." ::= { ptpTrapPrefix 22 } managementPortStatusTrap NOTIFICATION-TYPE OBJECTS { managementPortStatus } STATUS current DESCRIPTION "Current status of the out-of-band management link. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 23 } managementPortDisabledWarningTrap NOTIFICATION-TYPE OBJECTS { managementPortDisabledWarning } STATUS current DESCRIPTION "The SNMP ifAdminStatus of the out-of-band management interface has disabled Ethernet traffic" ::= { ptpTrapPrefix 24 } linkModeOptimizationMismatchTrap NOTIFICATION-TYPE OBJECTS { linkModeOptimizationMismatch } STATUS current DESCRIPTION "The remote node of this link has been configured with a different link mode optimization" ::= { ptpTrapPrefix 25 } managementPortConfigurationMismatchTrap NOTIFICATION-TYPE OBJECTS { managementPortConfigurationMismatch } STATUS current DESCRIPTION "The detection of Ethernet fragments (runt packets) when the link is in full duplex is an indication of an auto-negotiation or forced configuration mismatch. This alarm is only raised if an Out-of-Band Management Mode has been configured." ::= { ptpTrapPrefix 28 } syslogStateTrap NOTIFICATION-TYPE OBJECTS { syslogState } STATUS current DESCRIPTION "The syslog service has been enabled or disabled" ::= { ptpTrapPrefix 30 } syslogLocalNearlyFullTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "The syslog local log is nearly full (90%)" ::= { ptpTrapPrefix 31 } syslogLocalWrappedTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "The syslog local log has wrapped" ::= { ptpTrapPrefix 32 } syslogClientTrap NOTIFICATION-TYPE OBJECTS { syslogClient } STATUS current DESCRIPTION "Enable or disable the syslog client" ::= { ptpTrapPrefix 33 } secureModeAlarmTrap NOTIFICATION-TYPE OBJECTS { secureModeAlarm } STATUS current DESCRIPTION "The secure mode (e.g. FIPS, UC-APL) state of the unit. The secure mode is not configured(1) state indicates that the unit is capable of secure mode operation, and one or more of the following security materials has not been configured: Key Of Keys, Private Key, Public Certificate, DRNG Entropy Status, Wireless Encryption Key. The secure mode mode is configured but not active(2) state indicates that the unit is capable of secure mode operation, and the security material has been configured, but the configuration of interfaces is not consistent with secure mode operation. The secure mode is not supported(3) state indicates that the unit is not capable of secure mode operation. The secure mode capability requires appropriate hardware compatibility, license key and software image." ::= { ptpTrapPrefix 34 } ethernetBridgingStatusAlarmTrap NOTIFICATION-TYPE OBJECTS { ethernetBridgingStatusAlarm } STATUS current DESCRIPTION "Ethernet traffic bridging is disabled because the wireless link is not operating at the configured Lowest Ethernet Modulation Mode" ::= { ptpTrapPrefix 35 } END