CAMBIUM-PTP650-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, IpAddress, enterprises FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF DisplayString FROM SNMPv2-TC InetAddress, InetAddressType FROM INET-ADDRESS-MIB; cambium MODULE-IDENTITY LAST-UPDATED "201502060443Z" ORGANIZATION "Cambium Networks Ltd." CONTACT-INFO "Post: Simon Whitaker Cambium Networks Ltd. Unit B2, Linhay Business Park, Eastern Road, Ashburton, Devon. TQ13 7UP United Kingdom Phone: +44 (0) 1364 655 500 Email: simon.whitaker@cambiumnetworks.com" DESCRIPTION "MIB for non-line-of-sight (NLOS) wireless ethernet bridge." REVISION "201502060443Z" DESCRIPTION "PTP650-01-40: Added Second Data Service attributes to support a second data path over wireless link. Added support for Cable Diagnostics. Added IEEE 1588 Transparent Clock source port and Transparent Clock source alarm attributes." REVISION "201406181412Z" DESCRIPTION "PTP650-01-20: Added TDM group and NIDU attributes to support the telecomms interfaces. Added Router Protocols group to support Microwave Adaptive Bandwidth (MAB). Added support for Out-Of-Band Remote Management, and for mute and enable transmission. Renamed 'ethernet bridging' attributes to 'data bridging'. Made more SyncE attributes writable." REVISION "201402211503Z" DESCRIPTION "PTP650-01-10: Added Synchronous Ethernet (SyncE) and IEEE 1588 Transparent Clock. Support PTP650s. Clarified localPacketFiltering, regulatoryBand, TDD Sync status & alarm. TX power max increased to 30dBm. Modified the bit assignments of enabledDiagnosticAlarms to combine the various status & warning bits for the main PSU, Aux & SFP ports into a single portState bit." REVISION "201308021028Z" DESCRIPTION "PTP650-01-00: Initial revision." ::= { enterprises 17713 } -- Groups in cambium ptp OBJECT IDENTIFIER ::= { cambium 1 } ptmp OBJECT IDENTIFIER ::= { cambium 2 } ptp650 OBJECT IDENTIFIER ::= { cambium 7 } -- Groups in ptp650 dfs OBJECT IDENTIFIER ::= { ptp650 3 } bridge OBJECT IDENTIFIER ::= { ptp650 4 } configuration OBJECT IDENTIFIER ::= { ptp650 5 } ethernet OBJECT IDENTIFIER ::= { ptp650 6 } tDM OBJECT IDENTIFIER ::= { ptp650 7 } license OBJECT IDENTIFIER ::= { ptp650 8 } management OBJECT IDENTIFIER ::= { ptp650 9 } phyControl OBJECT IDENTIFIER ::= { ptp650 10 } phyStatus OBJECT IDENTIFIER ::= { ptp650 12 } alarms OBJECT IDENTIFIER ::= { ptp650 13 } smtp OBJECT IDENTIFIER ::= { ptp650 15 } snmpControl OBJECT IDENTIFIER ::= { ptp650 16 } sntp OBJECT IDENTIFIER ::= { ptp650 17 } reset OBJECT IDENTIFIER ::= { ptp650 18 } versions OBJECT IDENTIFIER ::= { ptp650 19 } pubStats OBJECT IDENTIFIER ::= { ptp650 20 } encryption OBJECT IDENTIFIER ::= { ptp650 22 } tDDControl OBJECT IDENTIFIER ::= { ptp650 23 } aAAControl OBJECT IDENTIFIER ::= { ptp650 25 } syslogControl OBJECT IDENTIFIER ::= { ptp650 24 } routerProtocols OBJECT IDENTIFIER ::= { ptp650 26 } cableDiagnostics OBJECT IDENTIFIER ::= { ptp650 27 } supplementary OBJECT IDENTIFIER ::= { ptp650 96 } ptpGroups OBJECT IDENTIFIER ::= { ptp650 98 } ptpTraps OBJECT IDENTIFIER ::= { ptp650 99 } ptpTrapPrefix OBJECT IDENTIFIER ::= { ptpTraps 0 } -- Compliance information -- ptpCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for the Cambium PTP MIB" MODULE -- this module MANDATORY-GROUPS { dfsGroup , bridgeGroup , configurationGroup , ethernetGroup , tDMGroup , licenseGroup , managementGroup , phyControlGroup , phyStatusGroup , alarmsGroup , smtpGroup , snmpControlGroup , sntpGroup , resetGroup , versionsGroup , pubStatsGroup , encryptionGroup , tDDControlGroup , aAAControlGroup , syslogControlGroup , routerProtocolsGroup , cableDiagnosticsGroup , supplementaryGroup , notificationsGroup } ::= { ptp650 97 } dfsGroup OBJECT-GROUP OBJECTS { dfsTableNumber , extendedSpectrumScanning , dfsMeans , dfsNineNinePointNinePercentiles , dfsPeaks } STATUS current DESCRIPTION "The dfs object group." ::= { ptpGroups 3 } bridgeGroup OBJECT-GROUP OBJECTS { localPacketFiltering } STATUS current DESCRIPTION "The bridge object group." ::= { ptpGroups 4 } configurationGroup OBJECT-GROUP OBJECTS { iPv4Address , subnetMask , gatewayIPAddress , targetMACAddress , masterSlaveMode , maximumTransmitPower , antennaGain , cableLoss , eIRP , channelBandwidth , linkName , siteName , accessMethod , groupID , iPv6Address , iPVersion , iPv6AutoConfiguredLinkLocalAddress , iPv6PrefixLength , iPv6GatewayAddress , remoteInternetAddressType , remoteInternetAddress , subbandLowestFrequency , subbandHighestFrequency , enableTransmission } STATUS current DESCRIPTION "The configuration object group." ::= { ptpGroups 5 } ethernetGroup OBJECT-GROUP OBJECTS { mainPSUPortAutoNegotiation , mainPSUPortAutoNegAdvertisement , mainPSUPortAutoMdix , mainPSUPortStatus , mainPSUPortSpeedAndDuplex , dataPortWirelessDownAlert , useVLANForManagementInterfaces , vLANManagementPriority , vLANManagementVID , auxPortStatus , auxPortSpeedAndDuplex , ethernetPriorityTableNumber , l2CPPriorityTableNumber , iPDSCPPriorityTableNumber , mPLSTCPriorityTableNumber , managementPortWirelessDownAlert , qOSPriorityScheme , unknownNetworkPriorityQueueMapping , dSCPManagementPriority , dataBridgingStatus , mainPSUPortAllocation , auxPortAllocation , sFPPortAllocation , dataPortPauseFrames , sFPPortAutoNegotiation , sFPPortAutoNegAdvertisement , sFPPortAutoMdix , sFPPortStatus , sFPPortSpeedAndDuplex , auxPortPowerOverEthernetOutput , auxPortPowerOverEthernetOutputStatus , syncETracking , syncEEquipmentClock , mainPSUPortQLRxOverwrite , mainPSUPortSSMTx , sFPPortSSMTx , auxPortSSMTx , syncETrackingState , mainPSUPortQLRx , auxPortQLRx , sFPPortQLRx , mainPSUPortQLTx , auxPortQLTx , sFPPortQLTx , mainPSUPortSyncEMasterSlaveStatus , auxPortSyncEMasterSlaveStatus , sFPPortSyncEMasterSlaveStatus , mainPSUPortGigabitMasterSlaveStatus , auxPortGigabitMasterSlaveStatus , sFPPortGigabitMasterSlaveStatus , transparentClock , transparentClockVLAN , transparentClockVID , mainPSUPortAcceptedQLRx , auxPortAcceptedQLRx , sFPPortAcceptedQLRx , mainPSUPortSyncERxStatus , auxPortSyncERxStatus , sFPPortSyncERxStatus , nIDULanPortStatus , nIDULanPortSpeedAndDuplex , oOBPriorityQueueMapping , nIDULanPortAutoNegotiation , nIDULanPortAutoNegAdvertisement , nIDULanPortAutoMdix , nIDULanPortGigabitMasterSlaveStatus , txMABFrames , managementNetworkAccessEnabled , secondDataPortPauseFrames , secondDataBridgingStatus , transparentClockPort , ethernetPriorityQueueMapping , l2CPPriorityQueueMapping , iPDSCPPriorityQueueMapping , mPLSTCPriorityQueueMapping } STATUS current DESCRIPTION "The ethernet object group." ::= { ptpGroups 6 } tDMGroup OBJECT-GROUP OBJECTS { tDMInterfaceControl , tDMInterfaceStatus , tDMEnabledChannels , tdmTableNumber , tDMConfigurationMismatch , lowestTDMModulationMode , tDMChannelStatus , tDMChannelLineCode , tDMChannelCableLength , tDMChannelLoopback } STATUS current DESCRIPTION "The tDM object group." ::= { ptpGroups 7 } licenseGroup OBJECT-GROUP OBJECTS { regulatoryBand , productVariant , productName , frequencyVariant , sNMPv3Enable , licenseVersion , licenseUnitSerialNumber , licenseIssueNumber , licenseCountry , licenseNumberOfRegulatoryBands , licenseBandwidthCap , licenseEncryption , licenseSecurityLevel , licenseGroupAccess , licenseOOBManagementSupport , licenseSFPPortSupport , licenseAuxiliaryPortSupport , licenseCapacity , licenseMaxNumberOfTDMChannels , licenseIEEE1588Support , licenseSyncESupport , licenseIPv6Support , licenseMinimumFirmwareVersion , licenseFullCapabilityTrialStatus , licenseRemainingTrialPeriod , licenseRemainingTrialPeriodAlarm , capacityVariantMismatch , licenseTDDSyncSupport , licenseMaxLinkRange , licenseTrialPeriod , licenseRARSupport , licenseRegulatoryBandsList } STATUS current DESCRIPTION "The license object group." ::= { ptpGroups 8 } managementGroup OBJECT-GROUP OBJECTS { targetRange , rangingMode , installStatus , installArmState , tFTPServerPortNumber , tFTPSoftwareUpgradeFileName , tFTPStartSoftwareUpgrade , tFTPSoftwareUpgradeStatus , tFTPSoftwareUpgradeStatusText , tFTPSoftwareUpgradeStatusAdditionalText , hTTPAccessEnabled , telnetAccessEnabled , hTTPPortNumber , hTTPSPortNumber , telnetPortNumber , hTTPSAccessEnabled , tFTPServerInternetAddressType , tFTPServerInternetAddress , lowestDataModulationMode , lowestSecondDataModulationMode } STATUS current DESCRIPTION "The management object group." ::= { ptpGroups 9 } phyControlGroup OBJECT-GROUP OBJECTS { linkSymmetry , userConfiguredMaxModulationMode , linkModeOptimization , txColorCode , rxColorCode , remoteMaximumTransmitPower } STATUS current DESCRIPTION "The phyControl object group." ::= { ptpGroups 10 } phyStatusGroup OBJECT-GROUP OBJECTS { linkLoss , receivePower , vectorError , transmitPower , receiveChannel , transmitChannel , receiveFreqMHz , transmitFreqMHz , signalStrengthRatio , receiveFreqKHz , transmitFreqKHz , rawReceivePower , range , receiveModulationMode , transmitModulationMode , searchState } STATUS current DESCRIPTION "The phyStatus object group." ::= { ptpGroups 12 } alarmsGroup OBJECT-GROUP OBJECTS { unitOutOfCalibration , incompatibleRegulatoryBands , noWirelessChannelAvailable , wirelessLinkDisabledWarning , mainPSUPortDisabledWarning , sFPError , mainPSUPortConfigurationMismatch , incompatibleMasterAndSlave , tDDSynchronizationStatus , auxPortDisabledWarning , tDDSynchronizationAlarm , linkModeOptimizationMismatch , auxPortConfigurationMismatch , secureModeAlarm , dataBridgingStatusAlarm , sFPPortDisabledWarning , sFPPortConfigurationMismatch , maxLinkRangeExceeded , nIDULanPortDisabledWarning , nIDULanPortConfigurationMismatch , portAllocationMismatch , secondDataBridgingStatusAlarm , transparentClockSourcePortAlarm } STATUS current DESCRIPTION "The alarms object group." ::= { ptpGroups 13 } smtpGroup OBJECT-GROUP OBJECTS { sMTPEmailAlert , sMTPServerPortNumber , sMTPSourceEmailAddress , sMTPDestinationEmailAddress , sMTPEnabledMessages , sMTPServerInternetAddressType , sMTPServerInternetAddress } STATUS current DESCRIPTION "The smtp object group." ::= { ptpGroups 15 } snmpControlGroup OBJECT-GROUP OBJECTS { sNMPPortNumber , sNMPCommunityString , sNMPTrapTableNumber , sNMPTrapVersion , sNMPEnabledTraps , enabledDiagnosticAlarms , sNMPSendAllTrapsAtStartup , sNMPTrapPortNumber , sNMPTrapInternetAddressType , sNMPTrapInternetAddress , sNMPTrapReceiverEnabled } STATUS current DESCRIPTION "The snmpControl object group." ::= { ptpGroups 16 } sntpGroup OBJECT-GROUP OBJECTS { sNTPState , sNTPPollInterval , sNTPSync , sNTPLastSync , systemClock , timeZone , daylightSaving , sNTPPrimaryServer , sNTPPrimaryServerDeadTime , sNTPServerRetries , sNTPServerTimeout , sNTPServerTableNumber , sNTPServerPortNumber , sNTPServerStatus , sNTPServerInternetAddressType , sNTPServerInternetAddress } STATUS current DESCRIPTION "The sntp object group." ::= { ptpGroups 17 } resetGroup OBJECT-GROUP OBJECTS { systemReset } STATUS current DESCRIPTION "The reset object group." ::= { ptpGroups 18 } versionsGroup OBJECT-GROUP OBJECTS { softwareVersion , hardwareVersion , secondarySoftwareVersion , bootVersion } STATUS current DESCRIPTION "The versions object group." ::= { ptpGroups 19 } pubStatsGroup OBJECT-GROUP OBJECTS { receiveDataRate , transmitDataRate , aggregateDataRate , wirelessLinkAvailability , wirelessLinkStatus , byteErrorRatio , receiveModulationModeDetail , dataBridgingAvailability } STATUS current DESCRIPTION "The pubStats object group." ::= { ptpGroups 20 } encryptionGroup OBJECT-GROUP OBJECTS { encryptionAlgorithm } STATUS current DESCRIPTION "The encryption object group." ::= { ptpGroups 22 } tDDControlGroup OBJECT-GROUP OBJECTS { tDDSynchronizationMode } STATUS current DESCRIPTION "The tDDControl object group." ::= { ptpGroups 23 } aAAControlGroup OBJECT-GROUP OBJECTS { userTableNumber , userName , userRole , userEnabled , userPassword } STATUS current DESCRIPTION "The aAAControl object group." ::= { ptpGroups 25 } syslogControlGroup OBJECT-GROUP OBJECTS { syslogClient , syslogState } STATUS current DESCRIPTION "The syslogControl object group." ::= { ptpGroups 24 } routerProtocolsGroup OBJECT-GROUP OBJECTS { microwaveAdaptiveBandwidth , mABNominalModulationMode , mABTransmissionInterval , mABHoldoffPeriod , mABMaintenanceLevel , useVLANForMABProtocol , mABProtocolVID , mABProtocolVLANPriority , mABState , mABNominalTransmitCapacity , mABCurrentTransmitCapacity } STATUS current DESCRIPTION "The routerProtocols object group." ::= { ptpGroups 26 } cableDiagnosticsGroup OBJECT-GROUP OBJECTS { cableDiagnosticsPorts , cableDiagnosticsControl , cableDiagnosticsWarning , cableDiagnosticsResultTableNumber , cableDiagnosticsResultsDateTime , cableDiagPair1Results , cableDiagPair1Distance , cableDiagPair2Results , cableDiagPair2Distance , cableDiagPair3Results , cableDiagPair3Distance , cableDiagPair4Results , cableDiagPair4Distance } STATUS current DESCRIPTION "The cableDiagnostics object group." ::= { ptpGroups 27 } supplementaryGroup OBJECT-GROUP OBJECTS { longitude , latitude , altitude } STATUS current DESCRIPTION "The supplementary object group." ::= { ptpGroups 96 } notificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { channelChangeTrap , dfsImpulsiveInterferenceTrap , mainPSUPortStatusTrap , mainPSUPortDisabledWarningTrap , mainPSUPortConfigurationMismatchTrap , auxPortStatusTrap , auxPortDisabledWarningTrap , regulatoryBandTrap , installStatusTrap , installArmStateTrap , unitOutOfCalibrationTrap , auxPortPowerOverEthernetOutputStatusTrap , incompatibleRegulatoryBandsTrap , noWirelessChannelAvailableTrap , wirelessLinkDisabledWarningTrap , auxPortConfigurationMismatchTrap , sFPErrorTrap , sFPPortStatusTrap , incompatibleMasterAndSlaveTrap , sNTPSyncTrap , tDDSynchronizationAlarmTrap , sFPPortDisabledWarningTrap , sFPPortConfigurationMismatchTrap , linkModeOptimizationMismatchTrap , tDMInterfaceStatusTrap , tDMChannelStatusTrap , tDMChannelLoopbackTrap , nIDULanPortStatusTrap , syslogStateTrap , syslogLocalNearlyFullTrap , syslogLocalWrappedTrap , syslogClientTrap , secureModeAlarmTrap , dataBridgingStatusAlarmTrap , licenseRemainingTrialPeriodAlarmTrap , capacityVariantMismatchTrap , maxLinkRangeExceededTrap , tDMConfigurationMismatchTrap , nIDULanPortDisabledWarningTrap , nIDULanPortConfigurationMismatchTrap , secondDataBridgingStatusAlarmTrap , transparentClockSourcePortAlarmTrap , portAllocationMismatchTrap } STATUS current DESCRIPTION "The notifications group." ::= { ptpGroups 99 } DfsTableEntry ::= SEQUENCE { dfsTableIndex INTEGER , dfsMeans Integer32 , dfsNineNinePointNinePercentiles Integer32 , dfsPeaks Integer32 } dfsTable OBJECT-TYPE SYNTAX SEQUENCE OF DfsTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " A table storing a snapshot of various DFS measurements for each channel" ::= { dfs 2 } dfsTableEntry OBJECT-TYPE SYNTAX DfsTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table DfsTable" INDEX { dfsTableIndex } ::= { dfsTable 1 } EthernetPriorityTableEntry ::= SEQUENCE { ethernetPriorityTableIndex INTEGER , ethernetPriorityQueueMapping INTEGER } ethernetPriorityTable OBJECT-TYPE SYNTAX SEQUENCE OF EthernetPriorityTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " A priority queue mapping table. This is a list of packet queues indexed by Ethernet priority." ::= { ethernet 15 } ethernetPriorityTableEntry OBJECT-TYPE SYNTAX EthernetPriorityTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table EthernetPriorityTable" INDEX { ethernetPriorityTableIndex } ::= { ethernetPriorityTable 1 } L2CPPriorityTableEntry ::= SEQUENCE { l2CPPriorityTableIndex INTEGER , l2CPPriorityQueueMapping INTEGER } l2CPPriorityTable OBJECT-TYPE SYNTAX SEQUENCE OF L2CPPriorityTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " A priority queue mapping table. This is a list of packet queues indexed by L2CP priority." ::= { ethernet 17 } l2CPPriorityTableEntry OBJECT-TYPE SYNTAX L2CPPriorityTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table L2CPPriorityTable" INDEX { l2CPPriorityTableIndex } ::= { l2CPPriorityTable 1 } IPDSCPPriorityTableEntry ::= SEQUENCE { iPDSCPPriorityTableIndex INTEGER , iPDSCPPriorityQueueMapping INTEGER } iPDSCPPriorityTable OBJECT-TYPE SYNTAX SEQUENCE OF IPDSCPPriorityTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " A priority queue mapping table. This is a list of packet queues indexed by L3 IP DSCP priority." ::= { ethernet 19 } iPDSCPPriorityTableEntry OBJECT-TYPE SYNTAX IPDSCPPriorityTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table IPDSCPPriorityTable" INDEX { iPDSCPPriorityTableIndex } ::= { iPDSCPPriorityTable 1 } MPLSTCPriorityTableEntry ::= SEQUENCE { mPLSTCPriorityTableIndex INTEGER , mPLSTCPriorityQueueMapping INTEGER } mPLSTCPriorityTable OBJECT-TYPE SYNTAX SEQUENCE OF MPLSTCPriorityTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " A priority queue mapping table. This is a list of priority queues indexed by MPLS TC priority." ::= { ethernet 21 } mPLSTCPriorityTableEntry OBJECT-TYPE SYNTAX MPLSTCPriorityTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table MPLSTCPriorityTable" INDEX { mPLSTCPriorityTableIndex } ::= { mPLSTCPriorityTable 1 } TdmTableEntry ::= SEQUENCE { tdmTableIndex INTEGER , tDMChannelStatus INTEGER , tDMChannelLineCode INTEGER , tDMChannelCableLength INTEGER , tDMChannelLoopback INTEGER } tdmTable OBJECT-TYPE SYNTAX SEQUENCE OF TdmTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " A table storing a configuration and status for each TDM channel" ::= { tDM 5 } tdmTableEntry OBJECT-TYPE SYNTAX TdmTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table TdmTable" INDEX { tdmTableIndex } ::= { tdmTable 1 } LicenseRegulatoryBandsTableEntry ::= SEQUENCE { licenseRegulatoryBandsTableIndex INTEGER , licenseRegulatoryBandsList INTEGER } licenseRegulatoryBandsTable OBJECT-TYPE SYNTAX SEQUENCE OF LicenseRegulatoryBandsTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { license 18 } licenseRegulatoryBandsTableEntry OBJECT-TYPE SYNTAX LicenseRegulatoryBandsTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table LicenseRegulatoryBandsTable" INDEX { licenseRegulatoryBandsTableIndex } ::= { licenseRegulatoryBandsTable 1 } SNMPTrapTableEntry ::= SEQUENCE { sNMPTrapTableIndex INTEGER , sNMPTrapPortNumber INTEGER , sNMPTrapInternetAddressType INTEGER , sNMPTrapInternetAddress InetAddress , sNMPTrapReceiverEnabled INTEGER } sNMPTrapTable OBJECT-TYPE SYNTAX SEQUENCE OF SNMPTrapTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " SNMP trap configuration table." ::= { snmpControl 4 } sNMPTrapTableEntry OBJECT-TYPE SYNTAX SNMPTrapTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table SNMPTrapTable" INDEX { sNMPTrapTableIndex } ::= { sNMPTrapTable 1 } SNTPServerTableEntry ::= SEQUENCE { sNTPServerTableIndex INTEGER , sNTPServerPortNumber INTEGER , sNTPServerStatus DisplayString , sNTPServerInternetAddressType INTEGER , sNTPServerInternetAddress InetAddress } sNTPServerTable OBJECT-TYPE SYNTAX SEQUENCE OF SNTPServerTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { sntp 15 } sNTPServerTableEntry OBJECT-TYPE SYNTAX SNTPServerTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table SNTPServerTable" INDEX { sNTPServerTableIndex } ::= { sNTPServerTable 1 } UserTableEntry ::= SEQUENCE { userTableIndex INTEGER , userName DisplayString , userRole INTEGER , userEnabled INTEGER , userPassword DisplayString } userTable OBJECT-TYPE SYNTAX SEQUENCE OF UserTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The User Table Control group contains objects specifically for user account management." ::= { aAAControl 2 } userTableEntry OBJECT-TYPE SYNTAX UserTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table UserTable" INDEX { userTableIndex } ::= { userTable 1 } CableDiagnosticsResultTableEntry ::= SEQUENCE { cableDiagnosticsResultTableIndex INTEGER , cableDiagnosticsResultsDateTime Integer32 , cableDiagPair1Results INTEGER , cableDiagPair1Distance Integer32 , cableDiagPair2Results INTEGER , cableDiagPair2Distance Integer32 , cableDiagPair3Results INTEGER , cableDiagPair3Distance Integer32 , cableDiagPair4Results INTEGER , cableDiagPair4Distance Integer32 } cableDiagnosticsResultTable OBJECT-TYPE SYNTAX SEQUENCE OF CableDiagnosticsResultTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { cableDiagnostics 5 } cableDiagnosticsResultTableEntry OBJECT-TYPE SYNTAX CableDiagnosticsResultTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table CableDiagnosticsResultTable" INDEX { cableDiagnosticsResultTableIndex } ::= { cableDiagnosticsResultTable 1 } -- Dfs group attribute definitions -- dfsTableNumber OBJECT-TYPE SYNTAX INTEGER (1..63) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the dfsTable" ::= { dfs 1 } extendedSpectrumScanning OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables Extended Spectrum Scanning" ::= { dfs 3 } -- DfsTable group attribute definitions -- dfsTableIndex OBJECT-TYPE SYNTAX INTEGER (1..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "used to index values in the dfsTable." ::= { dfsTableEntry 1 } dfsMeans OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Snapshot of DFS means" ::= { dfsTableEntry 2 } dfsNineNinePointNinePercentiles OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Snapshot of DFS 99.9 percentiles" ::= { dfsTableEntry 3 } dfsPeaks OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Snapshot of DFS peaks" ::= { dfsTableEntry 4 } -- Bridge group attribute definitions -- localPacketFiltering OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "When Local Packet Filtering is Enabled, the unit keeps track of the port (Main, SFP, Aux or Wireless) on which a packet with a given MAC source address destined to the management agent has been received. This MAC address to port mapping is then used in order to route any response from the management agent to the right port. When Local Packet Filtering is Disabled, any Ethernet packet from the management agent is sent to all ports." ::= { bridge 1 } -- Configuration group attribute definitions -- iPv4Address OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Internet protocol (IPv4) address. This address is used by the family of Internet protocols to uniquely identify the unit on a network." ::= { configuration 1 } subnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "A subnet allows the flow of network traffic between hosts to be segregated based on a network configuration. By organizing hosts into logical groups, subnetting can improve network security and performance." ::= { configuration 2 } gatewayIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IPv4 address of a device on the current network that acts as an IPv4 network gateway. A gateway acts as an entrance / exit to packets from / to other networks" ::= { configuration 3 } targetMACAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) MAX-ACCESS read-only STATUS current DESCRIPTION "MAC address of the PTP wireless unit forming the other end of the PTP link" ::= { configuration 4 } masterSlaveMode OBJECT-TYPE SYNTAX INTEGER { master(0), slave(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The PTP wireless link operates using a master and slave relationship" ::= { configuration 5 } maximumTransmitPower OBJECT-TYPE SYNTAX INTEGER (-15..30) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum transmit power the wireless unit is permitted to use when establishing and maintaining the wireless link. This may be reduced during installation" ::= { configuration 6 } antennaGain OBJECT-TYPE SYNTAX INTEGER (130..610) MAX-ACCESS read-write STATUS current DESCRIPTION "Antenna Gain. Expressed in 10ths of dBi." ::= { configuration 7 } cableLoss OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Loss in the cable between the ODU and the antenna. Expressed in 10ths of dB. NB: This attribute is ignored for variants with an integral antenna." ::= { configuration 8 } eIRP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Effective Isotropic Radiated Power (EIRP) describes the strength of the radio signal leaving the wireless unit. Expressed in 10ths of dBm" ::= { configuration 9 } channelBandwidth OBJECT-TYPE SYNTAX INTEGER { bw30MHz(0), bw15MHz(1), bw10MHz(2), bw5MHz(3), bw20MHz(4), bw56MHz(5), bw50MHz(6), bw40MHz(7), bw45MHz(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "This control sets the bandwidth of the transmit and receive radio channels" ::= { configuration 11 } linkName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "Name of the PTP link allocated by the System Administrator. Used to establish a connection with the correct PTP wireless unit at the other end of the link. NOTE: The link name MUST be the same at both ends of the PTP link." ::= { configuration 14 } siteName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "This field contains a user-provided description of the site name together with any additional notes" ::= { configuration 15 } accessMethod OBJECT-TYPE SYNTAX INTEGER { linkAccess(0), linkNameAccess(1), groupAccess(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "ODUs must be configured in pairs before a link can be established. The Access Method attribute determines how the paired ODUs will recognise each other. For the Link Access method, each ODU must be configured with Target MAC Address equal to the MAC Address of the other unit. For the Link Name Access method, both units must be configured with the same Link Name. For the Group Access method, both units must be configured with the same Group ID." ::= { configuration 16 } groupID OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "When Access Method is set to Group Access, the Group ID identifies all the units belonging to the same group" ::= { configuration 17 } iPv6Address OBJECT-TYPE SYNTAX DisplayString (SIZE(0..39)) MAX-ACCESS read-write STATUS current DESCRIPTION "Internet protocol (IPv6) address. This address is used by the family of Internet protocols to uniquely identify the unit on a network." ::= { configuration 18 } iPVersion OBJECT-TYPE SYNTAX INTEGER { iPv4(0), iPv6(1), dualIPv4andIPv6(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "IP protocol selection. Choice of IPv4, IPv6 or Dual." ::= { configuration 20 } iPv6AutoConfiguredLinkLocalAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..39)) MAX-ACCESS read-only STATUS current DESCRIPTION "The auto configured link local IPv6 address" ::= { configuration 21 } iPv6PrefixLength OBJECT-TYPE SYNTAX INTEGER (0..128) MAX-ACCESS read-write STATUS current DESCRIPTION "IPv6 prefix length" ::= { configuration 22 } iPv6GatewayAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..39)) MAX-ACCESS read-write STATUS current DESCRIPTION "The IPv6 address of a device on the current network that is currently acting as an IPv6 network gateway. A gateway acts as an entrance / exit to packets from / to other networks." ::= { configuration 23 } remoteInternetAddressType OBJECT-TYPE SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), unknown6(5), unknown7(6), unknown8(7), unknown9(8), unknown10(9), unknown11(10), unknown12(11), unknown13(12), unknown14(13), unknown15(14), unknown16(15), dns(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of Internet address specified by the associated remoteInternetAddressType." ::= { configuration 24 } remoteInternetAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-only STATUS current DESCRIPTION "INET address used to identify the peer wireless unit" ::= { configuration 25 } subbandLowestFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Lowest center frequency of the subset of channels." ::= { configuration 26 } subbandHighestFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Highest center frequency of the subset of channels." ::= { configuration 27 } enableTransmission OBJECT-TYPE SYNTAX INTEGER { enabled(0), muted(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Control for enabling/disabling the radio transmitter of the Master. Note: Use Web Properties to control this feature." ::= { configuration 28 } -- Ethernet group attribute definitions -- mainPSUPortAutoNegotiation OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This controls whether the local Ethernet interface configuration is automatically negotiated or forced. Do not use a forced setting together with auto negotiation at the Ethernet link partner. If you want to run your Ethernet link at a fixed speed and duplex then you would normally leave auto negotiation enabled and only enable the single Auto Neg Advertisement option that you want the link to run in - FORCING ETHERNET CONFIGURATION IS A LAST RESORT WHICH SHOULD ONLY BE PERFORMED IF YOU ARE HAVING PROBLEMS WITH AUTO NEGOTIATION - AND YOU MUST ENSURE THAT YOU CONFIGURE BOTH THIS UNIT AND THE ETHERNET LINK PARTNER TO WHICH IT IS CONNECTED IDENTICALLY (THE LINK PARTNER MUST NOT HAVE AUTO NEGOTIATION ENABLED EITHER, OTHERWISE A DUPLEX MISMATCH WILL OCCUR). NB: The new setting will only take effect after a system reboot." ::= { ethernet 1 } mainPSUPortAutoNegAdvertisement OBJECT-TYPE SYNTAX BITS { negInvalid(2), neg10MbpsHalfDuplex(3), neg10MbpsFullDuplex(4), neg100MbpsHalfDuplex(5), neg100MbpsFullDuplex(6), neg1000MbpsFullDuplex(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This sets the different Ethernet configurations that will be advertised during auto negotiation. Note the new setting will only take effect after a system reboot. WARNING: Duplex mismatch may result if both ends of the Ethernet link do not have the same settings. Do not auto negotiation together with a fixed setting at the Ethernet link partner. WARNING: Make sure that you select option(s) that you know your connected equipment can cater for!" ::= { ethernet 2 } mainPSUPortAutoMdix OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This enables/disables the Auto MDI/MDIX capability. NB: The new setting will only take effect after a system reboot" ::= { ethernet 3 } mainPSUPortStatus OBJECT-TYPE SYNTAX INTEGER { down(0), copperLinkUp(1), fiberLinkUp(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of the Main PSU Ethernet link. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ethernet 4 } mainPSUPortSpeedAndDuplex OBJECT-TYPE SYNTAX INTEGER { speed1000MbpsFullDuplex(0), speed100MbpsFullDuplex(1), speed100MbpsHalfDuplex(2), speed10MbpsFullDuplex(3), speed10MbpsHalfDuplex(4), speedUnknown6(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current speed and duplex of the Main PSU Ethernet link" ::= { ethernet 5 } dataPortWirelessDownAlert OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "When enabled, this causes the Ethernet link to be dropped briefly when the wireless link drops. This is so that spanning tree algorithms can quickly detect that there is a problem." ::= { ethernet 6 } useVLANForManagementInterfaces OBJECT-TYPE SYNTAX INTEGER { noVLANTagging(0), iEEE8021QTaggedCTagType8100(1), iEEE8021adTaggedSTagorBTagType88a8(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls whether the management interfaces (WWW/SNMP/SMTP/SNTP) use VLAN tags or not. NB: The new setting will only take effect after a system reboot" ::= { ethernet 7 } vLANManagementPriority OBJECT-TYPE SYNTAX INTEGER { p0(0), p1(1), p2(2), p3(3), p4(4), p5(5), p6(6), p7(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This VLAN Priority (0-7) will be included in packets generated by the management interfaces" ::= { ethernet 8 } vLANManagementVID OBJECT-TYPE SYNTAX INTEGER (0..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "This VLAN VID (0-4094) will be included in packets generated by the management interfaces. Note the new setting will only take effect after a system reboot" ::= { ethernet 11 } auxPortStatus OBJECT-TYPE SYNTAX INTEGER { down(0), copperLinkUp(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of the Aux Ethernet link. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ethernet 12 } auxPortSpeedAndDuplex OBJECT-TYPE SYNTAX INTEGER { speed1000MbpsFullDuplex(0), speed100MbpsFullDuplex(1), speed100MbpsHalfDuplex(2), speed10MbpsFullDuplex(3), speed10MbpsHalfDuplex(4), speedUnknown6(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current speed and duplex of the Aux Ethernet link" ::= { ethernet 13 } ethernetPriorityTableNumber OBJECT-TYPE SYNTAX INTEGER (9) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the vLANPriorityTable." ::= { ethernet 14 } l2CPPriorityTableNumber OBJECT-TYPE SYNTAX INTEGER (5) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the l2CPPriorityTable." ::= { ethernet 16 } iPDSCPPriorityTableNumber OBJECT-TYPE SYNTAX INTEGER (64) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the iPDSCPPriorityTable." ::= { ethernet 18 } mPLSTCPriorityTableNumber OBJECT-TYPE SYNTAX INTEGER (8) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the mPLSTCPriorityTable." ::= { ethernet 20 } managementPortWirelessDownAlert OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "When enabled, this causes the management link to be dropped briefly when the wireless link drops. This is so that spanning tree algorithms can quickly detect that there is a problem." ::= { ethernet 23 } qOSPriorityScheme OBJECT-TYPE SYNTAX INTEGER { ethernet(0), iPMPLS(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects classification based on fields in the Ethernet header (Layer 2) or in the Network header (Layer 3). The unit recognises two network layer protocols: IP and MPLS" ::= { ethernet 24 } unknownNetworkPriorityQueueMapping OBJECT-TYPE SYNTAX INTEGER { q0(0), q1(1), q2(2), q3(3), q4(4), q5(5), q6(6), q7(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Configures the classification of unknown network protocols to an egress queue at the wireless port. Unknown means something other than IP and MPLS" ::= { ethernet 25 } dSCPManagementPriority OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION "This Differentiated Services Code Point value will be inserted in the IP Header of all IP Datagrams transmitted by the management interfaces" ::= { ethernet 26 } dataBridgingStatus OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of Ethernet Data traffic bridging over the wireless link" ::= { ethernet 27 } mainPSUPortAllocation OBJECT-TYPE SYNTAX INTEGER { disabled(0), dataOnly(1), dataandInBandManagement(2), outofBandLocalManagement(3), outofBandRemoteManagement(4), secondDataOnly(5), secondDataandInBandManagement(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the service or services supported by the Main PSU Ethernet port" ::= { ethernet 28 } auxPortAllocation OBJECT-TYPE SYNTAX INTEGER { disabled(0), dataOnly(1), dataandInBandManagement(2), outofBandLocalManagement(3), outofBandRemoteManagement(4), secondDataOnly(5), secondDataandInBandManagement(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the service or services supported by the Aux Ethernet port" ::= { ethernet 29 } sFPPortAllocation OBJECT-TYPE SYNTAX INTEGER { disabled(0), dataOnly(1), dataandInBandManagement(2), outofBandLocalManagement(3), outofBandRemoteManagement(4), secondDataOnly(5), secondDataandInBandManagement(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the service or services supported by the SFP Ethernet port" ::= { ethernet 30 } dataPortPauseFrames OBJECT-TYPE SYNTAX INTEGER { tunnel(0), discard(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Controls whether the bridge tunnels or discards Layer 2 PAUSE frames arriving at the Data Port. Such frames are identified by the destination MAC Address being equal to 01-80-C2-00-00-01" ::= { ethernet 31 } sFPPortAutoNegotiation OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This controls whether the local SFP Ethernet interface configuration is automatically negotiated or forced. Do not use a forced setting together with auto negotiation at the Ethernet link partner. If you want to run your Ethernet link at a fixed speed and duplex then you would normally leave auto negotiation enabled and only enable the single Auto Neg Advertisement option that you want the link to run in - FORCING ETHERNET CONFIGURATION IS A LAST RESORT WHICH SHOULD ONLY BE PERFORMED IF YOU ARE HAVING PROBLEMS WITH AUTO NEGOTIATION - AND YOU MUST ENSURE THAT YOU CONFIGURE BOTH THIS UNIT AND THE ETHERNET LINK PARTNER TO WHICH IT IS CONNECTED IDENTICALLY (THE LINK PARTNER MUST NOT HAVE AUTO NEGOTIATION ENABLED EITHER, OTHERWISE A DUPLEX MISMATCH WILL OCCUR). NB: The new setting will only take effect after a system reboot." ::= { ethernet 32 } sFPPortAutoNegAdvertisement OBJECT-TYPE SYNTAX BITS { negInvalid(2), neg10MbpsHalfDuplex(3), neg10MbpsFullDuplex(4), neg100MbpsHalfDuplex(5), neg100MbpsFullDuplex(6), neg1000MbpsFullDuplex(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This sets the different SFP Ethernet configurations that will be advertised during auto negotiation. Note the new setting will only take effect after a system reboot. WARNING: Duplex mismatch may result if both ends of the Ethernet link do not have the same settings. Do not auto negotiation together with a fixed setting at the Ethernet link partner. WARNING: Make sure that you select option(s) that you know your connected equipment can cater for!" ::= { ethernet 33 } sFPPortAutoMdix OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This enables/disables the Auto MDI/MDIX capability. NB: The new setting will only take effect after a system reboot" ::= { ethernet 34 } sFPPortStatus OBJECT-TYPE SYNTAX INTEGER { down(0), copperLinkUp(1), fiberLinkUp(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of the SFP Ethernet link. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ethernet 35 } sFPPortSpeedAndDuplex OBJECT-TYPE SYNTAX INTEGER { speed1000MbpsFullDuplex(0), speed100MbpsFullDuplex(1), speed100MbpsHalfDuplex(2), speed10MbpsFullDuplex(3), speed10MbpsHalfDuplex(4), speedUnknown6(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current speed and duplex of the SFP Ethernet link" ::= { ethernet 36 } auxPortPowerOverEthernetOutput OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of the Power Over Ethernet (PoE) output of the Aux port. Enabling PoE output may lead to system instability; please refer to the User Guide before enabling this control" ::= { ethernet 37 } auxPortPowerOverEthernetOutputStatus OBJECT-TYPE SYNTAX INTEGER { poEOutputOn(0), poEOutputDisabled(1), poEOutputEnabledbutNotActiveErrororNoLoadPresent(2), poEOutputOverloadError(3), poEOutputOverTempError(4), poEOutputErrorDetected(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of the Power Over Ethernet (PoE) output of the Aux port" ::= { ethernet 38 } syncETracking OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1), internalTDMUseOnly(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether Synchronous Ethernet (SyncE) network synchronization is enabled." ::= { ethernet 39 } syncEEquipmentClock OBJECT-TYPE SYNTAX INTEGER { eECOption1(0), eECOption2(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "EEC-Option 1 applies to synchronous Ethernet equipments that are designed to interwork with networks optimized for the 2048-kbit/s hierarchy. Corresponds to ITU-T G.813 Option 1; EEC-Option 2 applies to synchronous Ethernet equipments that are designed to interwork with networks optimized for the 1544-kbit/s hierarchy. Corresponds to Type IV clock from ITU-T G.812." ::= { ethernet 40 } mainPSUPortQLRxOverwrite OBJECT-TYPE SYNTAX INTEGER { disabled(0), qLPRS(1), qLSTU(2), qLPRC(3), qLST2(4), qLSSUAQLTNC(5), qLSSUB(6), qLST3E(7), qLEEC2QLST3(8), qLEEC1QLSEC(9), qLSMC(10), qLPROV(11), qLDNUQLDUS(12) } MAX-ACCESS read-write STATUS current DESCRIPTION "Override for the Synchronous Ethernet (SyncE) received Quality Level (QL) on the main PSU port." ::= { ethernet 41 } mainPSUPortSSMTx OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the Synchronous Ethernet (SyncE) Quality Level (QL) is transmitted on the Main PSU port" ::= { ethernet 42 } sFPPortSSMTx OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the Synchronous Ethernet (SyncE) Quality Level (QL) is transmitted on the SFP port" ::= { ethernet 43 } auxPortSSMTx OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the Synchronous Ethernet (SyncE) Quality Level (QL) is transmitted on the Aux port" ::= { ethernet 44 } syncETrackingState OBJECT-TYPE SYNTAX INTEGER { disabled(0), acquiringWirelessLock(1), freeRunning(2), lockedLocalAcquiringHoldover(3), lockedLocalHoldoverAcquired(4), holdover(5), lockedRemoteAcquiringHoldover(6), lockedRemoteHoldoverAcquired(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of Synchronous Ethernet (SyncE) network synchronization." ::= { ethernet 45 } mainPSUPortQLRx OBJECT-TYPE SYNTAX INTEGER { none(0), qLPRS(1), qLSTU(2), qLPRC(3), qLST2(4), qLSSUAQLTNC(5), qLSSUB(6), qLST3E(7), qLEEC2QLST3(8), qLEEC1QLSEC(9), qLSMC(10), qLPROV(11), qLDNUQLDUS(12), qLFAILED(13) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Synchronous Ethernet (SyncE) Quality Level (QL) currently being received on the main PSU port." ::= { ethernet 46 } auxPortQLRx OBJECT-TYPE SYNTAX INTEGER { none(0), qLPRS(1), qLSTU(2), qLPRC(3), qLST2(4), qLSSUAQLTNC(5), qLSSUB(6), qLST3E(7), qLEEC2QLST3(8), qLEEC1QLSEC(9), qLSMC(10), qLPROV(11), qLDNUQLDUS(12), qLFAILED(13) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Synchronous Ethernet (SyncE) Quality Level (QL) currently being received on the auxiliary port." ::= { ethernet 47 } sFPPortQLRx OBJECT-TYPE SYNTAX INTEGER { none(0), qLPRS(1), qLSTU(2), qLPRC(3), qLST2(4), qLSSUAQLTNC(5), qLSSUB(6), qLST3E(7), qLEEC2QLST3(8), qLEEC1QLSEC(9), qLSMC(10), qLPROV(11), qLDNUQLDUS(12), qLFAILED(13) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Synchronous Ethernet (SyncE) Quality Level (QL) currently being received on the SFP port." ::= { ethernet 48 } mainPSUPortQLTx OBJECT-TYPE SYNTAX INTEGER { none(0), qLPRS(1), qLSTU(2), qLPRC(3), qLST2(4), qLSSUAQLTNC(5), qLSSUB(6), qLST3E(7), qLEEC2QLST3(8), qLEEC1QLSEC(9), qLSMC(10), qLPROV(11), qLDNUQLDUS(12) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Synchronous Ethernet (SyncE) transmit Quality Level (QL) of the main PSU port." ::= { ethernet 49 } auxPortQLTx OBJECT-TYPE SYNTAX INTEGER { none(0), qLPRS(1), qLSTU(2), qLPRC(3), qLST2(4), qLSSUAQLTNC(5), qLSSUB(6), qLST3E(7), qLEEC2QLST3(8), qLEEC1QLSEC(9), qLSMC(10), qLPROV(11), qLDNUQLDUS(12) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Synchronous Ethernet (SyncE) transmit Quality Level (QL) of the auxiliary port." ::= { ethernet 50 } sFPPortQLTx OBJECT-TYPE SYNTAX INTEGER { none(0), qLPRS(1), qLSTU(2), qLPRC(3), qLST2(4), qLSSUAQLTNC(5), qLSSUB(6), qLST3E(7), qLEEC2QLST3(8), qLEEC1QLSEC(9), qLSMC(10), qLPROV(11), qLDNUQLDUS(12) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Synchronous Ethernet (SyncE) transmit Quality Level (QL) of the SFP port." ::= { ethernet 51 } mainPSUPortSyncEMasterSlaveStatus OBJECT-TYPE SYNTAX INTEGER { master(0), slave(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The main PSU port Synchronous Ethernet (SyncE) Master/Slave status" ::= { ethernet 52 } auxPortSyncEMasterSlaveStatus OBJECT-TYPE SYNTAX INTEGER { master(0), slave(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The auxiliary port Synchronous Ethernet (SyncE) Master/Slave status" ::= { ethernet 53 } sFPPortSyncEMasterSlaveStatus OBJECT-TYPE SYNTAX INTEGER { master(0), slave(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The SFP port Synchronous Ethernet (SyncE) Master/Slave status" ::= { ethernet 54 } mainPSUPortGigabitMasterSlaveStatus OBJECT-TYPE SYNTAX INTEGER { master(0), slave(1), notApplicable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The main PSU port Gigabit Ethernet Master/Slave status" ::= { ethernet 55 } auxPortGigabitMasterSlaveStatus OBJECT-TYPE SYNTAX INTEGER { master(0), slave(1), notApplicable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The auxiliary port Gigabit Ethernet Master/Slave status" ::= { ethernet 56 } sFPPortGigabitMasterSlaveStatus OBJECT-TYPE SYNTAX INTEGER { master(0), slave(1), notApplicable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The SFP port Gigabit Ethernet Master/Slave status" ::= { ethernet 57 } transparentClock OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This control enables the Precision Time Protocol (IEEE-1588) Transparent Clock. Once enabled the unit will modify the correction field in PTP event messages to take account of the time these frames have been resident in this system. This will happen for all PTP frames at Layer 2 & Layer 3 (IPv4 & IPv6) unless a transparent clock VLAN is enabled." ::= { ethernet 58 } transparentClockVLAN OBJECT-TYPE SYNTAX INTEGER { all(0), sTagged(1), cTagged(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "If All is selected then all PTP frames will have their correction fields modified with the residence time. If an S-TAG or C-TAG is selected, only frames with this VLAN tag and matching the VLAN ID in the Transparent Clock VID will have their correction fields modified." ::= { ethernet 59 } transparentClockVID OBJECT-TYPE SYNTAX INTEGER (0..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "The VLAN ID which frames must match if they are to be corrected. Only valid when an S-TAG or C-TAG has been selected." ::= { ethernet 60 } mainPSUPortAcceptedQLRx OBJECT-TYPE SYNTAX INTEGER { none(0), qLPRS(1), qLSTU(2), qLPRC(3), qLST2(4), qLSSUAQLTNC(5), qLSSUB(6), qLST3E(7), qLEEC2QLST3(8), qLEEC1QLSEC(9), qLSMC(10), qLPROV(11), qLDNUQLDUS(12), qLFAILED(13) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Synchronous Ethernet (SyncE) Quality Level (QL) currently accepted (validated) on the main PSU port." ::= { ethernet 61 } auxPortAcceptedQLRx OBJECT-TYPE SYNTAX INTEGER { none(0), qLPRS(1), qLSTU(2), qLPRC(3), qLST2(4), qLSSUAQLTNC(5), qLSSUB(6), qLST3E(7), qLEEC2QLST3(8), qLEEC1QLSEC(9), qLSMC(10), qLPROV(11), qLDNUQLDUS(12), qLFAILED(13) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Synchronous Ethernet (SyncE) Quality Level (QL) currently accepted (validated) on the auxiliary port." ::= { ethernet 62 } sFPPortAcceptedQLRx OBJECT-TYPE SYNTAX INTEGER { none(0), qLPRS(1), qLSTU(2), qLPRC(3), qLST2(4), qLSSUAQLTNC(5), qLSSUB(6), qLST3E(7), qLEEC2QLST3(8), qLEEC1QLSEC(9), qLSMC(10), qLPROV(11), qLDNUQLDUS(12), qLFAILED(13) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Synchronous Ethernet (SyncE) Quality Level (QL) currently accepted (validated) on the SFP port." ::= { ethernet 63 } mainPSUPortSyncERxStatus OBJECT-TYPE SYNTAX INTEGER { good(0), waittoRestore(1), failed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Synchronous Ethernet (SyncE) Receive Status of the main PSU port" ::= { ethernet 64 } auxPortSyncERxStatus OBJECT-TYPE SYNTAX INTEGER { good(0), waittoRestore(1), failed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Synchronous Ethernet (SyncE) Receive Status of the auxiliary port" ::= { ethernet 65 } sFPPortSyncERxStatus OBJECT-TYPE SYNTAX INTEGER { good(0), waittoRestore(1), failed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Synchronous Ethernet (SyncE) Receive Status of the SFP port" ::= { ethernet 66 } nIDULanPortStatus OBJECT-TYPE SYNTAX INTEGER { down(0), copperLinkUp(1), fiberLinkUp(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of the NIDU LAN Ethernet link. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ethernet 67 } nIDULanPortSpeedAndDuplex OBJECT-TYPE SYNTAX INTEGER { speed1000MbpsFullDuplex(0), speed100MbpsFullDuplex(1), speed100MbpsHalfDuplex(2), speed10MbpsFullDuplex(3), speed10MbpsHalfDuplex(4), speedUnknown6(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current speed and duplex of the Ethernet link to the NIDU LAN Port" ::= { ethernet 68 } oOBPriorityQueueMapping OBJECT-TYPE SYNTAX INTEGER { q0(0), q1(1), q2(2), q3(3), q4(4), q5(5), q6(6), q7(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Configures the classification of traffic to an egress queue at the wireless port" ::= { ethernet 69 } nIDULanPortAutoNegotiation OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This controls whether the local Ethernet interface configuration is automatically negotiated or forced. Do not use a forced setting together with auto negotiation at the Ethernet link partner. If you want to run your Ethernet link at a fixed speed and duplex then you would normally leave auto negotiation enabled and only enable the single Auto Neg Advertisement option that you want the link to run in - FORCING ETHERNET CONFIGURATION IS A LAST RESORT WHICH SHOULD ONLY BE PERFORMED IF YOU ARE HAVING PROBLEMS WITH AUTO NEGOTIATION - AND YOU MUST ENSURE THAT YOU CONFIGURE BOTH THIS UNIT AND THE ETHERNET LINK PARTNER TO WHICH IT IS CONNECTED IDENTICALLY (THE LINK PARTNER MUST NOT HAVE AUTO NEGOTIATION ENABLED EITHER, OTHERWISE A DUPLEX MISMATCH WILL OCCUR). NB: The new setting will only take effect after a system reboot." ::= { ethernet 70 } nIDULanPortAutoNegAdvertisement OBJECT-TYPE SYNTAX BITS { negInvalid(2), neg10MbpsHalfDuplex(3), neg10MbpsFullDuplex(4), neg100MbpsHalfDuplex(5), neg100MbpsFullDuplex(6), neg1000MbpsFullDuplex(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This sets the different Ethernet configurations that will be advertised during auto negotiation. Note the new setting will only take effect after a system reboot. WARNING: Duplex mismatch may result if both ends of the Ethernet link do not have the same settings. Do not auto negotiation together with a fixed setting at the Ethernet link partner. WARNING: Make sure that you select option(s) that you know your connected equipment can cater for!" ::= { ethernet 71 } nIDULanPortAutoMdix OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This enables/disables the Auto MDI/MDIX capability. NB: The new setting will only take effect after a system reboot" ::= { ethernet 72 } nIDULanPortGigabitMasterSlaveStatus OBJECT-TYPE SYNTAX INTEGER { master(0), slave(1), notApplicable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The NIDU LAN port Gigabit Ethernet Master/Slave status" ::= { ethernet 73 } txMABFrames OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of MAB frames transmitted" ::= { ethernet 74 } managementNetworkAccessEnabled OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "When enabled the local Out-of-Band interface can be used to access the remote management network. If not enabled the local management agent can still be accessed from the remote management network and the local Out-of-Band interface" ::= { ethernet 75 } secondDataPortPauseFrames OBJECT-TYPE SYNTAX INTEGER { tunnel(0), discard(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Controls whether the bridge tunnels or discards Layer 2 PAUSE frames arriving at the Second Data Service Port. Such frames are identified by the destination MAC Address being equal to 01-80-C2-00-00-01" ::= { ethernet 76 } secondDataBridgingStatus OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of bridging Second Data Service Ethernet traffic over the wireless link" ::= { ethernet 80 } transparentClockPort OBJECT-TYPE SYNTAX INTEGER { mainPSU(0), aux(1), sFP(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "IEEE 1588 Transparent Clock source" ::= { ethernet 81 } -- EthernetPriorityTable group attribute definitions -- ethernetPriorityTableIndex OBJECT-TYPE SYNTAX INTEGER { p0(1), p1(2), p2(3), p3(4), p4(5), p5(6), p6(7), p7(8), untagged(9) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Ethernet priority flag, used to index values in the ethernetPriorityTable" ::= { ethernetPriorityTableEntry 1 } ethernetPriorityQueueMapping OBJECT-TYPE SYNTAX INTEGER { q0(0), q1(1), q2(2), q3(3), q4(4), q5(5), q6(6), q7(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Configures the classification of this Ethernet priority (also known as IEEE 802.1p value) to an egress queue at the wireless port" ::= { ethernetPriorityTableEntry 2 } -- L2CPPriorityTable group attribute definitions -- l2CPPriorityTableIndex OBJECT-TYPE SYNTAX INTEGER { bridge(1), mRP(2), cFM(3), rAPS(4), eAPS(5) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "L2CP priority flag, used to index values in the l2CPPriorityTable" ::= { l2CPPriorityTableEntry 1 } l2CPPriorityQueueMapping OBJECT-TYPE SYNTAX INTEGER { q0(0), q1(1), q2(2), q3(3), q4(4), q5(5), q6(6), q7(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Configures the classification of this layer two control protocol (L2CP) to an egress queue at the wireless port" ::= { l2CPPriorityTableEntry 2 } -- IPDSCPPriorityTable group attribute definitions -- iPDSCPPriorityTableIndex OBJECT-TYPE SYNTAX INTEGER (1..64) MAX-ACCESS not-accessible STATUS current DESCRIPTION "IP DSCP priority flag, used to index values in the iPDSCPPriorityTable" ::= { iPDSCPPriorityTableEntry 1 } iPDSCPPriorityQueueMapping OBJECT-TYPE SYNTAX INTEGER { q0(0), q1(1), q2(2), q3(3), q4(4), q5(5), q6(6), q7(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Configures the classification of this IP differentiated services code point (DSCP) value to an egress queue at the wireless port" ::= { iPDSCPPriorityTableEntry 2 } -- MPLSTCPriorityTable group attribute definitions -- mPLSTCPriorityTableIndex OBJECT-TYPE SYNTAX INTEGER (1..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION "MPLS TC priority flag, used to index values in the mPLSTCPriorityTable" ::= { mPLSTCPriorityTableEntry 1 } mPLSTCPriorityQueueMapping OBJECT-TYPE SYNTAX INTEGER { q0(0), q1(1), q2(2), q3(3), q4(4), q5(5), q6(6), q7(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Configures the classification of this MPLS traffic class (the field formerly known as EXP) to an egress queue at the wireless port" ::= { mPLSTCPriorityTableEntry 2 } -- TDM group attribute definitions -- tDMInterfaceControl OBJECT-TYPE SYNTAX INTEGER { none(0), e1(1), t1(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The line interface type. If this is set to 'None' then the TDM interfaces are disabled, and the TDM settings will be ignored." ::= { tDM 1 } tDMInterfaceStatus OBJECT-TYPE SYNTAX INTEGER { ok(0), connectedNotConfigured(1), notConnected(2), nIDUdetectedonAUXport(3), error(4), codeDownloadInProgress(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "@Current status of the connection to the TDM Box. A state of 'Up' on a green background indicates that the TDM Box is connected OK. When connecting a TDM Box only the Main Ethernet port should be used" ::= { tDM 2 } tDMEnabledChannels OBJECT-TYPE SYNTAX INTEGER (0..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of TDM channels enabled in the system" ::= { tDM 3 } tdmTableNumber OBJECT-TYPE SYNTAX INTEGER (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the TdmTable" ::= { tDM 4 } tDMConfigurationMismatch OBJECT-TYPE SYNTAX INTEGER { ok(0), linetypemismatch(1), enabledchannelsmismatch(2), linetypeandenabledchannelsmismatch(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of the configuration of the TDM Box. A state of 'Ok' on a green background indicates that the TDM Box configuration is matched OK with the remote end." ::= { tDM 6 } lowestTDMModulationMode OBJECT-TYPE SYNTAX INTEGER { modAcquisition(0), modBpsk63percent(1), modQpsk63percentSingle(2), modTransient1(3), modQpsk87percentSingle(4), modTransient2(5), mod16qam63percentSingleA(6), modTransient3(7), mod16qam87percentSingle(8), modTransient4(9), mod64qam75percentSingle(10), modTransient5(11), mod64qam92percentSingle(12), modTransient6(13), mod256qam81percentSingle(14), mod16qam63percentSingleB(15), mod16qam63percentDual(16), modTransient7(17), mod16qam87percentDual(18), modTransient8(19), mod64qam75percentDual(20), modTransient9(21), mod64qam92percentDual(22), modTransient10(23), mod256qam81percentDual(24) } MAX-ACCESS read-only STATUS current DESCRIPTION "The lowest modulation mode at which tdm data will be sent. The effective lowest modulation mode is displayed in the TDM Configuration page" ::= { tDM 7 } -- TdmTable group attribute definitions -- tdmTableIndex OBJECT-TYPE SYNTAX INTEGER (1..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION "TDM Channel flag, used to index channels in the TdmTable" ::= { tdmTableEntry 1 } tDMChannelStatus OBJECT-TYPE SYNTAX INTEGER { up(0), noSignalLocal(1), noSignalRemote(2), noSignalLocalandRemote(3), remoteTiming(4), noSignalLocalandRemoteTiming(5), disabled(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of the TDM channels. A value of 0 indicates that a TDM channel is established" ::= { tdmTableEntry 2 } tDMChannelLineCode OBJECT-TYPE SYNTAX INTEGER { aMI(0), b8ZSorHDB3(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The line code setting of the TDM interfaces. This must match the setting of the device connected to an interface" ::= { tdmTableEntry 3 } tDMChannelCableLength OBJECT-TYPE SYNTAX INTEGER { feet133(0), feet266(1), feet399(2), feet533(3), feet655(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The lengths of the cables connected to the TDM interfaces, measured in feet" ::= { tdmTableEntry 4 } tDMChannelLoopback OBJECT-TYPE SYNTAX INTEGER { none(0), copper(1), wireless(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The loopback status of TDM channels. This is intended for installation testing and should be set to 'None' for normal operation. The wire connections to a unit can be tested by applying a 'Copper' loopback to the local unit. The wireless connection to the remote unit can be tested by applying a 'Wireless' loopback to the remote unit with no loopback on the local unit. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { tdmTableEntry 5 } -- License group attribute definitions -- regulatoryBand OBJECT-TYPE SYNTAX INTEGER { regInvalid(0), reg158GHz(1), reg258GHz(2), reg358GHz(3), reg458GHz(4), reg558GHz(5), reg658GHz(6), reg754GHzUnrestrictedEIRPwithDFS(7), reg854GHzUnrestrictedEIRP(8), reg9(9), reg1058GHz(10), reg1158GHz(11), reg1254GHzFCCUNII2C(12), reg1354GHz(13), reg1449GHzPublicSafety(14), reg15(15), reg1659GHz(16), reg1759GHz(17), reg1849GHzPublicSafety(18), reg1958GHz(19), reg2054GHz(20), reg2154GHz(21), reg2258GHz(22), reg23(23), reg2458GHz(24), reg2558GHzETSI(25), reg2654GHzETSI(26), reg2758GHz(27), reg2858GHz(28), reg2958GHzUnrestrictedEIRPwithDFSandRTTT(29), reg3054GHz(30), reg3158GHz(31), reg3249GHzLicensed(32), reg3349GHzETSIBroadbandDisasterRelief(33), reg3458GHz(34), reg3558GHzUnrestrictedEIRP(35), reg3654GHz(36), reg3758GHz(37), reg3852GHzFCCUNII2A(38), reg3951GHzETSIBroadbandDisasterRelief(39), reg4054GHz(40), reg4154GHz(41), reg4254GHz(42), reg4354GHz(43), reg4458GHz(44), reg4558GHz(45), reg4658GHz(46), reg4758GHz(47), reg4858GHz(48), reg4958GHz(49), reg5058GHz(50), reg5158GHz(51), reg5258GHz(52), reg5358GHz(53), reg5458GHz(54), reg5558GHz(55), reg5654GHz(56), reg5754GHz(57), reg5858GHz(58), reg5958GHz(59), reg6058GHz(60), reg6149GHz(61), reg6252GHz(62), reg6352GHz(63), reg6451GHz(64), reg6551GHz(65), reg6651GHz(66), reg6752GHz(67), reg6852GHz(68), reg6952GHz(69), reg7052GHz(70), reg7152GHz(71), reg7252GHz(72), reg7352GHz(73), reg7452GHz(74), reg7552GHz(75), reg7652GHz(76), reg7752GHz(77), reg7849GHz(78), reg7954GHz(79), reg8049GHz(80), reg8147GHz(81), reg8247GHz(82), reg8352GHz(83), reg8451GHzFCCUNII1(84), reg8552GHzFCCUNII12A(85), reg8654GHzFCCUNII2A2C(86), reg8758GHz(87), reg8849GHz(88), reg8949GHz(89), reg9054GHzFCCUNII2CParabolicantenna(90), reg9152GHzFCCUNII2AParabolicantenna(91), reg9251GHzFCCUNII1Parabolicantenna(92), reg9349GHz(93), reg94(94), reg95(95), reg96(96), reg97(97), reg98(98), reg99(99), reg100(100), reg101(101), reg102(102), reg103(103), reg104(104), reg105(105), reg106(106), reg107(107), reg108(108), reg109(109), reg110(110), reg111(111), reg112(112), reg113(113), reg114(114), reg115(115), reg116(116), reg117(117), reg118(118), reg119(119), reg120(120), reg121(121), reg122(122), reg123(123), reg124(124), reg125(125), reg126(126), reg127(127), reg128(128), reg129(129), reg130(130), reg131(131), reg132(132), reg133(133), reg134(134), reg135(135), reg136(136), reg137(137), reg138(138), reg139(139), reg140(140), reg141(141), reg142(142), reg143(143), reg144(144), reg145(145), reg146(146), reg147(147), reg148(148), reg149(149), reg150(150), reg151(151), reg152(152), reg153(153), reg154(154), reg155(155), reg156(156), reg157(157), reg158(158), reg159(159), reg160(160), reg161(161), reg162(162), reg163(163), reg164(164), reg165(165), reg166(166), reg167(167), reg168(168), reg169(169), reg170(170), reg171(171), reg172(172), reg173(173), reg174(174), reg175(175), reg176(176), reg177(177), reg178(178), reg179(179), reg180(180), reg181(181), reg182(182), reg183(183), reg184(184), reg185(185), reg186(186), reg187(187), reg188(188), reg189(189), reg190(190), reg191(191), reg192(192), reg193(193), reg194(194), reg195(195), reg196(196), reg197(197), reg198(198), reg199(199), reg200(200), reg201(201), reg202(202), reg203(203), reg204(204), reg205(205), reg206(206), reg207(207), reg208(208), reg209(209), reg210(210), reg211(211), reg212(212), reg213(213), reg214(214), reg215(215), reg216(216), reg217(217), reg218(218), reg219(219), reg220(220), reg221(221), reg222(222), reg223(223), reg224(224), reg225(225), reg226(226), reg227(227), reg228(228), reg229(229), reg230(230), reg231(231), reg232(232), reg233(233), reg234(234), reg235(235), reg236(236), reg237(237), reg238(238), reg239(239), reg240(240), reg241(241), reg242(242), reg243(243), reg244(244), reg245(245), reg246(246), reg247(247), reg248(248), reg249(249), reg250(250), reg251(251), reg252(252), reg253(253), reg254(254), reg255(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Regulatory Band prohibits the wireless unit from operating outside the regulated limits. An invalid Regulatory Band may be caused by a missing or incorrect License Key, a corrupt MAC Address or an attempt to configure a Regulatory Band not allowed by the License Key. NB: a change of state may generate an SNMP trap and/or SMTP email alert." ::= { license 1 } productVariant OBJECT-TYPE SYNTAX INTEGER { pTPxx400Full(0), pTPxx400Deprecated1(1), pTPxx400Deprecated2(2), pTPxx400Lite(3), spare1(4), pTPxx300(5), spare2(6), spare3(7), pTPxx500FullDeprecated(8), pTPxx500LiteDeprecated(9), pTPxx500(10), pTPxx600Lite(11), pTPxx600Full(12), pTPxx650(13), spare6(14), pTP800(15) } MAX-ACCESS read-only STATUS current DESCRIPTION "The product variant" ::= { license 2 } productName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the product variant" ::= { license 3 } frequencyVariant OBJECT-TYPE SYNTAX INTEGER { freq5GHz(0), freq4GHz(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The hardware frequency variant" ::= { license 5 } sNMPv3Enable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "SNMPv3 availability control" ::= { license 9 } licenseVersion OBJECT-TYPE SYNTAX INTEGER (1) MAX-ACCESS read-only STATUS current DESCRIPTION "The license key version." ::= { license 12 } licenseUnitSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(0..11)) MAX-ACCESS read-only STATUS current DESCRIPTION "The unit serial number." ::= { license 13 } licenseIssueNumber OBJECT-TYPE SYNTAX INTEGER (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The license key issue number for this unit." ::= { license 15 } licenseCountry OBJECT-TYPE SYNTAX DisplayString (SIZE(0..103)) MAX-ACCESS read-only STATUS current DESCRIPTION "The country in which this unit is licensed to operate." ::= { license 16 } licenseNumberOfRegulatoryBands OBJECT-TYPE SYNTAX INTEGER (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of regulatory bands for which the unit is licensed to operate." ::= { license 17 } licenseBandwidthCap OBJECT-TYPE SYNTAX INTEGER (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The wireless link bandwidth cap in MHz. Zero indicates no bandwidth cap." ::= { license 20 } licenseEncryption OBJECT-TYPE SYNTAX INTEGER { none(0), aESRijndael(1), aES192bitRijndael(2), aES256bitRijndael(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The license key encryption algorithms available." ::= { license 21 } licenseSecurityLevel OBJECT-TYPE SYNTAX INTEGER { normal(0), fIPS(1), uCAPL(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The license key security level." ::= { license 22 } licenseGroupAccess OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The license key group access setting." ::= { license 23 } licenseOOBManagementSupport OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The license key Out-Of-Band (OOB) support setting." ::= { license 24 } licenseSFPPortSupport OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The license key Ethernet SFP Port support setting." ::= { license 25 } licenseAuxiliaryPortSupport OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The license key Ethernet Auxiliary Port support setting." ::= { license 26 } licenseCapacity OBJECT-TYPE SYNTAX INTEGER { full(0), mid(1), lite(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The license key capacity" ::= { license 27 } licenseMaxNumberOfTDMChannels OBJECT-TYPE SYNTAX INTEGER (0..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The license key maximum TDM channels setting. Zero indicates TDM not available." ::= { license 28 } licenseIEEE1588Support OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The license key IEEE-1588 support setting." ::= { license 29 } licenseSyncESupport OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The license key SyncE support setting." ::= { license 30 } licenseIPv6Support OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The license key IPv6 support setting." ::= { license 31 } licenseMinimumFirmwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..23)) MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum firmware version required to support this license key." ::= { license 32 } licenseFullCapabilityTrialStatus OBJECT-TYPE SYNTAX INTEGER { available(0), active(1), inactive(2), expired(3), unavailable(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The license key full capability trial period status." ::= { license 33 } licenseRemainingTrialPeriod OBJECT-TYPE SYNTAX INTEGER (0..31536000) MAX-ACCESS read-only STATUS current DESCRIPTION "The remaining time for the license key full capability trial period." ::= { license 34 } licenseRemainingTrialPeriodAlarm OBJECT-TYPE SYNTAX INTEGER { fullCapabilityTrialNotActiveOrMoreThan7DaysRemaining(0), fullCapabilityTrialExpiringInLessThan7Days(1), fullCapabilityTrialExpiringInLessThan6Days(2), fullCapabilityTrialExpiringInLessThan5Days(3), fullCapabilityTrialExpiringInLessThan4Days(4), fullCapabilityTrialExpiringInLessThan3Days(5), fullCapabilityTrialExpiringInLessThan2Days(6), fullCapabilityTrialExpiringInLessThan1Day(7), fullCapabilityTrialHasExpired(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "If the full capability trial license period is about to expire then purchase a license upgrade from your reseller." ::= { license 35 } capacityVariantMismatch OBJECT-TYPE SYNTAX INTEGER { noError(0), mismatchDetected(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The remote node of this link has a lower link capacity. Operating with a reduced effective link capacity." ::= { license 36 } licenseTDDSyncSupport OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The license key TDD Synchronization support setting." ::= { license 37 } licenseMaxLinkRange OBJECT-TYPE SYNTAX INTEGER (0..1999) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum licensed range for the wireless link in tenths of km. A value of zero indicates that the maximum link range is not limited by the license." ::= { license 38 } licenseTrialPeriod OBJECT-TYPE SYNTAX INTEGER (0..365) MAX-ACCESS read-only STATUS current DESCRIPTION "The license key maximum trial period, in days." ::= { license 39 } licenseRARSupport OBJECT-TYPE SYNTAX INTEGER { disabled(0), mAB(1), dLEP(2), mABandDLEP(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The license key Radio Aware Routing support setting." ::= { license 40 } -- LicenseRegulatoryBandsTable group attribute definitions -- licenseRegulatoryBandsTableIndex OBJECT-TYPE SYNTAX INTEGER (1..32) MAX-ACCESS not-accessible STATUS current DESCRIPTION "License regulatory bands, used to index the LicenseRegulatoryBandsTable." ::= { licenseRegulatoryBandsTableEntry 1 } licenseRegulatoryBandsList OBJECT-TYPE SYNTAX INTEGER { regInvalid(0), reg158GHz(1), reg258GHz(2), reg358GHz(3), reg458GHz(4), reg558GHz(5), reg658GHz(6), reg754GHzUnrestrictedEIRPwithDFS(7), reg854GHzUnrestrictedEIRP(8), reg9(9), reg1058GHz(10), reg1158GHz(11), reg1254GHzFCCUNII2C(12), reg1354GHz(13), reg1449GHzPublicSafety(14), reg15(15), reg1659GHz(16), reg1759GHz(17), reg1849GHzPublicSafety(18), reg1958GHz(19), reg2054GHz(20), reg2154GHz(21), reg2258GHz(22), reg23(23), reg2458GHz(24), reg2558GHzETSI(25), reg2654GHzETSI(26), reg2758GHz(27), reg2858GHz(28), reg2958GHzUnrestrictedEIRPwithDFSandRTTT(29), reg3054GHz(30), reg3158GHz(31), reg3249GHzLicensed(32), reg3349GHzETSIBroadbandDisasterRelief(33), reg3458GHz(34), reg3558GHzUnrestrictedEIRP(35), reg3654GHz(36), reg3758GHz(37), reg3852GHzFCCUNII2A(38), reg3951GHzETSIBroadbandDisasterRelief(39), reg4054GHz(40), reg4154GHz(41), reg4254GHz(42), reg4354GHz(43), reg4458GHz(44), reg4558GHz(45), reg4658GHz(46), reg4758GHz(47), reg4858GHz(48), reg4958GHz(49), reg5058GHz(50), reg5158GHz(51), reg5258GHz(52), reg5358GHz(53), reg5458GHz(54), reg5558GHz(55), reg5654GHz(56), reg5754GHz(57), reg5858GHz(58), reg5958GHz(59), reg6058GHz(60), reg6149GHz(61), reg6252GHz(62), reg6352GHz(63), reg6451GHz(64), reg6551GHz(65), reg6651GHz(66), reg6752GHz(67), reg6852GHz(68), reg6952GHz(69), reg7052GHz(70), reg7152GHz(71), reg7252GHz(72), reg7352GHz(73), reg7452GHz(74), reg7552GHz(75), reg7652GHz(76), reg7752GHz(77), reg7849GHz(78), reg7954GHz(79), reg8049GHz(80), reg8147GHz(81), reg8247GHz(82), reg8352GHz(83), reg8451GHzFCCUNII1(84), reg8552GHzFCCUNII12A(85), reg8654GHzFCCUNII2A2C(86), reg8758GHz(87), reg8849GHz(88), reg8949GHz(89), reg9054GHzFCCUNII2CParabolicantenna(90), reg9152GHzFCCUNII2AParabolicantenna(91), reg9251GHzFCCUNII1Parabolicantenna(92), reg9349GHz(93), reg94(94), reg95(95), reg96(96), reg97(97), reg98(98), reg99(99), reg100(100), reg101(101), reg102(102), reg103(103), reg104(104), reg105(105), reg106(106), reg107(107), reg108(108), reg109(109), reg110(110), reg111(111), reg112(112), reg113(113), reg114(114), reg115(115), reg116(116), reg117(117), reg118(118), reg119(119), reg120(120), reg121(121), reg122(122), reg123(123), reg124(124), reg125(125), reg126(126), reg127(127), reg128(128), reg129(129), reg130(130), reg131(131), reg132(132), reg133(133), reg134(134), reg135(135), reg136(136), reg137(137), reg138(138), reg139(139), reg140(140), reg141(141), reg142(142), reg143(143), reg144(144), reg145(145), reg146(146), reg147(147), reg148(148), reg149(149), reg150(150), reg151(151), reg152(152), reg153(153), reg154(154), reg155(155), reg156(156), reg157(157), reg158(158), reg159(159), reg160(160), reg161(161), reg162(162), reg163(163), reg164(164), reg165(165), reg166(166), reg167(167), reg168(168), reg169(169), reg170(170), reg171(171), reg172(172), reg173(173), reg174(174), reg175(175), reg176(176), reg177(177), reg178(178), reg179(179), reg180(180), reg181(181), reg182(182), reg183(183), reg184(184), reg185(185), reg186(186), reg187(187), reg188(188), reg189(189), reg190(190), reg191(191), reg192(192), reg193(193), reg194(194), reg195(195), reg196(196), reg197(197), reg198(198), reg199(199), reg200(200), reg201(201), reg202(202), reg203(203), reg204(204), reg205(205), reg206(206), reg207(207), reg208(208), reg209(209), reg210(210), reg211(211), reg212(212), reg213(213), reg214(214), reg215(215), reg216(216), reg217(217), reg218(218), reg219(219), reg220(220), reg221(221), reg222(222), reg223(223), reg224(224), reg225(225), reg226(226), reg227(227), reg228(228), reg229(229), reg230(230), reg231(231), reg232(232), reg233(233), reg234(234), reg235(235), reg236(236), reg237(237), reg238(238), reg239(239), reg240(240), reg241(241), reg242(242), reg243(243), reg244(244), reg245(245), reg246(246), reg247(247), reg248(248), reg249(249), reg250(250), reg251(251), reg252(252), reg253(253), reg254(254), reg255(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The list of regulatory bands for which the unit is licensed to operate. A regulatory band prohibits the wireless unit from operating outside the regulated limits. An invalid regulatory band indicates a corrupted license key. NB: a change of state may generate an SNMP trap and/or SMTP email alert." ::= { licenseRegulatoryBandsTableEntry 2 } -- Management group attribute definitions -- targetRange OBJECT-TYPE SYNTAX INTEGER (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "Initial target range used in installation +/-1, expressed in tenths of a kilometer. When Auto-Ranging this must be set to 0" ::= { management 1 } rangingMode OBJECT-TYPE SYNTAX INTEGER { auto0to40km(0), auto0to100km(1), auto0to200km(2), targetRange(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of ranging to use during installation, either Auto-Ranging or use a selectable Target Range" ::= { management 2 } installStatus OBJECT-TYPE SYNTAX INTEGER { ok(0), wrongPeer(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "A non-zero value indicates that signalling was received with the wrong MAC address or a mismatched link name. NB: It is very unusual to detect this, because units with mis-configured Target MAC Address will normally fail to establish a wireless link. However, rare circumstances may establish a partial wireless link and detect this situation. NB: A non-zero value on start-up, or a change of value during operation, may generate an SNMP trap and/or SMTP email alert" ::= { management 3 } installArmState OBJECT-TYPE SYNTAX INTEGER { disarmed(0), armed(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if the unit is being installed. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { management 4 } tFTPServerPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The port number of the TFTP Server from which the TFTP Software Upgrade File Name will be retrieved" ::= { management 6 } tFTPSoftwareUpgradeFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..127)) MAX-ACCESS read-write STATUS current DESCRIPTION "Filename of the Software Upgrade to be loaded from the TFTP Server" ::= { management 7 } tFTPStartSoftwareUpgrade OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Write '1' to this attribute to start the TFTP software upgrade process. The attribute will be reset to 0 when the upgrade process has finished. Continuing with the software upgrade will cause spectrum management (DSO) channel metrics collection to stop. The wireless unit will no longer search for the optimal operational radio channel. The performance of this wireless link may deterioate over time. If operating in a regulatory band where RADAR detection is mandatory you must complete the software upgrade and reboot the unit. Channel metrics collection will only be restarted after the wireless unit has been rebooted" ::= { management 8 } tFTPSoftwareUpgradeStatus OBJECT-TYPE SYNTAX INTEGER { idle(0), uploadinprogress(1), uploadsuccessfulprogrammingFLASH(2), upgradesuccessfulreboottorunthenewsoftwareimage(3), upgradefailed(4), upgradewarning(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of the TFTP Software upgrade process" ::= { management 9 } tFTPSoftwareUpgradeStatusText OBJECT-TYPE SYNTAX DisplayString (SIZE(0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Descriptive text describing the status of the TFTP Software upgrade process, including any error details" ::= { management 10 } tFTPSoftwareUpgradeStatusAdditionalText OBJECT-TYPE SYNTAX DisplayString (SIZE(0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Any additional text describing the status of the TFTP Software upgrade process, including any error details" ::= { management 11 } hTTPAccessEnabled OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls whether or not HTTP access is enabled, i.e. if this is disabled (0) then the unit will not respond to any requests on the HTTP port. Remote management via HTTPS is not affected by this setting. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = Enabled)" ::= { management 12 } telnetAccessEnabled OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls whether or not Telnet access is enabled, i.e. if this is disabled (0) then the unit will not respond to any requests on the TELNET port. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = Disabled)" ::= { management 13 } hTTPPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This controls the port number for HTTP access. A value of zero will use the default port number. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = 80)" ::= { management 14 } hTTPSPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This controls the port number for HTTPS access. A value of zero will use the default port number. Availability of HTTPS is controlled via the License Key. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = 443)" ::= { management 15 } telnetPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This controls the port number for TELNET access. A value of zero will use the default port number. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = 23)" ::= { management 16 } hTTPSAccessEnabled OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls whether or not HTTPS access is enabled, i.e. if this is disabled (0) then the unit will not respond to any requests on the HTTPS port. Remote management via HTTP is not affected by this setting. Any change in this setting will not take effect until the unit has been rebooted. (Factory default = Enabled)" ::= { management 17 } tFTPServerInternetAddressType OBJECT-TYPE SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), unknown6(5), unknown7(6), unknown8(7), unknown9(8), unknown10(9), unknown11(10), unknown12(11), unknown13(12), unknown14(13), unknown15(14), unknown16(15), dns(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of Internet address specified by the associated tFTPServerInternetAddress." ::= { management 18 } tFTPServerInternetAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-write STATUS current DESCRIPTION "INET address of the TFTP Server from which the TFTP Software Upgrade File Name will be retrieved" ::= { management 19 } lowestDataModulationMode OBJECT-TYPE SYNTAX INTEGER { modAcquisition(0), modBpsk63percent(1), modQpsk63percentSingle(2), modTransient1(3), modQpsk87percentSingle(4), modTransient2(5), mod16qam63percentSingleA(6), modTransient3(7), mod16qam87percentSingle(8), modTransient4(9), mod64qam75percentSingle(10), modTransient5(11), mod64qam92percentSingle(12), modTransient6(13), mod256qam81percentSingle(14), mod16qam63percentSingleB(15), mod16qam63percentDual(16), modTransient7(17), mod16qam87percentDual(18), modTransient8(19), mod64qam75percentDual(20), modTransient9(21), mod64qam92percentDual(22), modTransient10(23), mod256qam81percentDual(24) } MAX-ACCESS read-only STATUS current DESCRIPTION "The lowest modulation mode at which Ethernet Data traffic will be bridged over the wireless link" ::= { management 20 } lowestSecondDataModulationMode OBJECT-TYPE SYNTAX INTEGER { modAcquisition(0), modBpsk63percent(1), modQpsk63percentSingle(2), modTransient1(3), modQpsk87percentSingle(4), modTransient2(5), mod16qam63percentSingleA(6), modTransient3(7), mod16qam87percentSingle(8), modTransient4(9), mod64qam75percentSingle(10), modTransient5(11), mod64qam92percentSingle(12), modTransient6(13), mod256qam81percentSingle(14), mod16qam63percentSingleB(15), mod16qam63percentDual(16), modTransient7(17), mod16qam87percentDual(18), modTransient8(19), mod64qam75percentDual(20), modTransient9(21), mod64qam92percentDual(22), modTransient10(23), mod256qam81percentDual(24) } MAX-ACCESS read-only STATUS current DESCRIPTION "The lowest modulation mode at which Second Data Service Ethernet traffic will be bridged over the wireless link" ::= { management 21 } -- PhyControl group attribute definitions -- linkSymmetry OBJECT-TYPE SYNTAX INTEGER { symmetryAdaptive(0), symmetry2to1(1), symmetry1to1(2), symmetry1to2(3), symmetry3to1(4), symmetry1to3(5), symmetry5to1(6), symmetry1to5(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Provides configuration options for sharing the available wireless capacity between the transmit and receive directions. Fixed link symmetry is defined by a ratio of the burst duration for the transmit direction to the burst duration for the receive direction. Permitted settings are 5:1, 3:1, 2:1, 1:1, 1:2, 1:3, 1:5. The 1:1 option provides fixed symmetric operation. The adaptive option selects transmit and receive burst durations automatically in response to the offered Ethernet traffic in each link direction. This attribute is valid only for a unit configured as a TDD Master" ::= { phyControl 1 } userConfiguredMaxModulationMode OBJECT-TYPE SYNTAX INTEGER { modBpsk63percent(0), modQpsk63percent(1), modQpsk87percent(2), mod16qam63percent(3), mod16qam87percent(4), mod64qam75percent(5), mod64qam92percent(6), mod256qam81percent(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum receive modulation mode controls the MAX mode used for adaptive modulation. NOTE: This attribute is automatically disabled when the installation agent is armed. To disarm the installation agent use the installation wizard" ::= { phyControl 2 } linkModeOptimization OBJECT-TYPE SYNTAX INTEGER { iPTraffic(0), tDMTraffic(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Optimizes the wireless link behavior for the type of traffic to be carried. In 'IP Traffic' mode, the wireless link will minimize transmission errors by automatically adapting the modulation mode. In 'TDM Traffic' mode, the wireless link will minimize transmission latency and preserve throughput by maintaining a higher modulation mode in the presence of a limited number of errors. The 'TDM Traffic' mode is recommended for E1/T1 applications and connectionless protocols." ::= { phyControl 3 } txColorCode OBJECT-TYPE SYNTAX INTEGER { a(0), b(1), c(2), d(3), e(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Transmit Color Code. This attribute need only be considered when the unit is installed in a network of PTP units and where some of the units are operating on the same frequency. In this case, the value would normally be derived by a network planner. In all other cases, it is recommended that this attribute is left at the default value. NOTE: For the link to operate, the value of this parameter must in all cases match the value of the Rx Color Code parameter at the far end of the link." ::= { phyControl 4 } rxColorCode OBJECT-TYPE SYNTAX INTEGER { a(0), b(1), c(2), d(3), e(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Receive Color Code. This attribute need only be considered when the unit is installed in a network of PTP units and where some of the units are operating on the same frequency. In this case, the value would normally be derived by a network planner. In all other cases, it is recommended that this attribute is left at the default value. NOTE: For the link to operate, the value of this parameter must in all cases match the value of the Tx Color Code parameter at the far end of the link." ::= { phyControl 5 } remoteMaximumTransmitPower OBJECT-TYPE SYNTAX INTEGER (-15..30) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum transmit power the remote wireless unit is permitted to use when establishing and maintaining the wireless link" ::= { phyControl 6 } -- PhyStatus group attribute definitions -- linkLoss OBJECT-TYPE SYNTAX INTEGER (-500..500) MAX-ACCESS read-only STATUS current DESCRIPTION "The wireless link loss expressed in tenths of a dB" ::= { phyStatus 1 } receivePower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Receive power expressed in tenths of a dBm" ::= { phyStatus 2 } vectorError OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The vector error measurement compares the received signal's IQ modulation characteristics to an ideal signal to determine the composite error vector magnitude. The value represented by this attribute is the average vector error over the previous second expressed in tenths of a dB" ::= { phyStatus 3 } transmitPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Transmit power expressed in tenths of a dBm" ::= { phyStatus 4 } receiveChannel OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION "Current active receive channel" ::= { phyStatus 5 } transmitChannel OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION "Current active transmit channel" ::= { phyStatus 6 } receiveFreqMHz OBJECT-TYPE SYNTAX INTEGER (0..6050) MAX-ACCESS read-only STATUS current DESCRIPTION "Current receive frequency expressed in integer MHz" ::= { phyStatus 7 } transmitFreqMHz OBJECT-TYPE SYNTAX INTEGER (0..6050) MAX-ACCESS read-only STATUS current DESCRIPTION "Current transmit frequency expressed in integer MHz" ::= { phyStatus 8 } signalStrengthRatio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Signal strength ratio (Vertical / Horizontal) : the number of dB larger the Vertical antenna input is than the Horizontal antenna input expressed in tenths of a dB" ::= { phyStatus 9 } receiveFreqKHz OBJECT-TYPE SYNTAX INTEGER (0..6050000) MAX-ACCESS read-only STATUS current DESCRIPTION "Current receive frequency expressed as KHz" ::= { phyStatus 10 } transmitFreqKHz OBJECT-TYPE SYNTAX INTEGER (0..6050000) MAX-ACCESS read-only STATUS current DESCRIPTION "Current transmit frequency expressed as KHz" ::= { phyStatus 11 } rawReceivePower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Raw receive power expressed in tenths of a dBm" ::= { phyStatus 12 } range OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Distance between the two peer wireless units expressed in tenths of a kilometer" ::= { phyStatus 13 } receiveModulationMode OBJECT-TYPE SYNTAX INTEGER { modAcquisition(0), modBpsk63percent(1), modQpsk63percentSingle(2), modTransient1(3), modQpsk87percentSingle(4), modTransient2(5), mod16qam63percentSingleA(6), modTransient3(7), mod16qam87percentSingle(8), modTransient4(9), mod64qam75percentSingle(10), modTransient5(11), mod64qam92percentSingle(12), modTransient6(13), mod256qam81percentSingle(14), mod16qam63percentSingleB(15), mod16qam63percentDual(16), modTransient7(17), mod16qam87percentDual(18), modTransient8(19), mod64qam75percentDual(20), modTransient9(21), mod64qam92percentDual(22), modTransient10(23), mod256qam81percentDual(24) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current active receive modulation mode" ::= { phyStatus 14 } transmitModulationMode OBJECT-TYPE SYNTAX INTEGER { modAcquisition(0), modBpsk63percent(1), modQpsk63percentSingle(2), modTransient1(3), modQpsk87percentSingle(4), modTransient2(5), mod16qam63percentSingleA(6), modTransient3(7), mod16qam87percentSingle(8), modTransient4(9), mod64qam75percentSingle(10), modTransient5(11), mod64qam92percentSingle(12), modTransient6(13), mod256qam81percentSingle(14), mod16qam63percentSingleB(15), mod16qam63percentDual(16), modTransient7(17), mod16qam87percentDual(18), modTransient8(19), mod64qam75percentDual(20), modTransient9(21), mod64qam92percentDual(22), modTransient10(23), mod256qam81percentDual(24) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current active transmit modulation mode" ::= { phyStatus 15 } searchState OBJECT-TYPE SYNTAX INTEGER { registering(0), searching(1), acquiring(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Search status of the wireless modem. 'Registering' means that the modem has locked to an OFDM signal, and the wireless link is up. 'Searching' means that no wireless signal has been detected. 'Acquiring' means that a wireless signal has been detected, but the modem has not locked to an OFDM signal." ::= { phyStatus 16 } -- Alarms group attribute definitions -- unitOutOfCalibration OBJECT-TYPE SYNTAX INTEGER { calibrated(0), partialCalibration(1), invalidCalibration(2), bandwidthvariantunsupportedPAsShutdown(3), outOfCalibrationPAsShutdown(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The unit is out of calibration" ::= { alarms 1 } incompatibleRegulatoryBands OBJECT-TYPE SYNTAX INTEGER { regOK(0), regIncompatibleLicenseKeys(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The master and slave units have incompatible regulatory bands. NB: Both units must have compatible license keys" ::= { alarms 4 } noWirelessChannelAvailable OBJECT-TYPE SYNTAX INTEGER { ok(0), noWirelessChannelAvailable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Spectrum Management was unable to locate a suitable wireless channel to operate on" ::= { alarms 5 } wirelessLinkDisabledWarning OBJECT-TYPE SYNTAX INTEGER { ok(0), disabledBySNMPifAdminStatus(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The SNMP ifAdminStatus of the wireless interface has disabled wireless traffic" ::= { alarms 6 } mainPSUPortDisabledWarning OBJECT-TYPE SYNTAX INTEGER { ok(0), disabledBySNMPifAdminStatus(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The SNMP ifAdminStatus of the interface has disabled Ethernet traffic" ::= { alarms 7 } sFPError OBJECT-TYPE SYNTAX INTEGER { ok(0), installedSFPNotLicensed(1), fiberLinkNotEstablishedButLOSNotDetected(2), fiberLinkNotEstablishedAndLOSDetected(3), installedSFPNotSupported(4), sFPInitializationFailed(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "If the SFP link is not OK, there are five possible causes: Either a SFP has been installed but the license key does not include SFP fiber support, a fiber link could not be established even though no LOS was detected (i.e. an optical carrier was detected, which could be due to a broken TX fiber, or because the link is disabled at the fiber link partner), a fiber link could not be established and LOS is detected (i.e. no optical carrier is detected), the installed SFP is not supported or the installed SFP failed to initialize correctly. NB: a change of status may generate an SNMP trap and/or SMTP email alert" ::= { alarms 8 } mainPSUPortConfigurationMismatch OBJECT-TYPE SYNTAX INTEGER { noError(0), mismatchDetected(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The detection of Ethernet fragments (runt packets) when the link is in full duplex is an indication of an auto-negotiation or forced configuration mismatch" ::= { alarms 9 } incompatibleMasterAndSlave OBJECT-TYPE SYNTAX INTEGER { ok(0), incompatibleProductVariants(1), differentSoftwareVersionsRunning(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "A non-zero value indicates that the master and slave ends of a link are different hardware products, or have different software versions. NB: It is very unusual to detect this, because incompatible units will normally fail to establish a wireless link. However, some combinations may establish a partial wireless link and detect this situation. NB: A non-zero value may generate an SNMP trap and/or SMTP email alert" ::= { alarms 10 } tDDSynchronizationStatus OBJECT-TYPE SYNTAX INTEGER { locked(0), holdover(1), holdoverNoGPSSyncIn(2), notSynchronized(3), notSynchronizedNoGPSSyncIn(4), pTPSYNCNotConnected(5), initialising(6), clusterTimingMaster(7), acquiringLock(8), inactive(9) } MAX-ACCESS read-only STATUS current DESCRIPTION "An alarm value (displayed in red) indicates that one of the following conditions has not been met (i) An external timing system is connected or internal timing has been configured. (ii) The timing system is providing a useable reference. (iii) The ODU is locked to this reference." ::= { alarms 11 } auxPortDisabledWarning OBJECT-TYPE SYNTAX INTEGER { ok(0), disabledBySNMPifAdminStatus(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The SNMP ifAdminStatus of the interface has disabled Ethernet traffic" ::= { alarms 12 } tDDSynchronizationAlarm OBJECT-TYPE SYNTAX INTEGER { ok(0), synchronizationLost(1), referenceSignalLost(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Not Synchronized indicates failure of the external timing system for a period greater than the holdover timer. TDD frame timing will have drifted, and this link may cause interference with other links in a synchronized network. Timing System Failure is an early warning, indicating that 80% of the holdover period has expired." ::= { alarms 13 } linkModeOptimizationMismatch OBJECT-TYPE SYNTAX INTEGER { ok(0), linkModeOptimizationMismatch(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The remote node of this link has been configured with a different link mode optimization" ::= { alarms 14 } auxPortConfigurationMismatch OBJECT-TYPE SYNTAX INTEGER { noError(0), mismatchDetected(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The detection of Ethernet fragments (runt packets) when the link is in full duplex is an indication of an auto-negotiation or forced configuration mismatch. This alarm is only raised if an Out-of-Band Management Mode has been configured." ::= { alarms 15 } secureModeAlarm OBJECT-TYPE SYNTAX INTEGER { secureModeIsActive(0), secureModeIsNotConfigured(1), secureModeIsConfiguredButNotActive(2), secureModeIsNotSupported(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The secure mode (e.g. FIPS, UC-APL) state of the unit. The secure mode is not configured(1) state indicates that the unit is capable of secure mode operation, and one or more of the following security materials has not been configured: Key Of Keys, Private Key, Public Certificate, DRNG Entropy Status, Wireless Encryption Key. The secure mode mode is configured but not active(2) state indicates that the unit is capable of secure mode operation, and the security material has been configured, but the configuration of interfaces is not consistent with secure mode operation. The secure mode is not supported(3) state indicates that the unit is not capable of secure mode operation. The secure mode capability requires appropriate hardware compatibility, license key and software image." ::= { alarms 16 } dataBridgingStatusAlarm OBJECT-TYPE SYNTAX INTEGER { bridgingEnabled(0), bridgingDisabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet Data traffic bridging is disabled because the wireless link is not operating at the configured Lowest Data Modulation Mode" ::= { alarms 17 } sFPPortDisabledWarning OBJECT-TYPE SYNTAX INTEGER { ok(0), disabledBySNMPifAdminStatus(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The SNMP ifAdminStatus of the interface has disabled Ethernet traffic" ::= { alarms 18 } sFPPortConfigurationMismatch OBJECT-TYPE SYNTAX INTEGER { noError(0), mismatchDetected(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The detection of Ethernet fragments (runt packets) when the link is in full duplex is an indication of an auto-negotiation or forced configuration mismatch. This alarm is only raised if an Out-of-Band Management Mode has been configured." ::= { alarms 19 } maxLinkRangeExceeded OBJECT-TYPE SYNTAX INTEGER { maxLinkRangeOK(0), maxLinkRangeExceeded(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The measured link range is greater than the maximum allowed by the license key. The link will operate at a reduced capacity while this condition applies. This alarm is only raised if the license specifies a maximum link range and the trial license is not active." ::= { alarms 20 } nIDULanPortDisabledWarning OBJECT-TYPE SYNTAX INTEGER { ok(0), disabledBySNMPifAdminStatus(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The SNMP ifAdminStatus of the interface has disabled Ethernet traffic" ::= { alarms 21 } nIDULanPortConfigurationMismatch OBJECT-TYPE SYNTAX INTEGER { noError(0), mismatchDetected(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The detection of Ethernet fragments (runt packets) when the link is in full duplex is an indication of an auto-negotiation or forced configuration mismatch." ::= { alarms 22 } portAllocationMismatch OBJECT-TYPE SYNTAX INTEGER { portAllocationOK(0), mismatchinSecondDataService(1), mismatchinOutofBandRemoteManagementService(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The local and remote ODUs have different services configured." ::= { alarms 23 } secondDataBridgingStatusAlarm OBJECT-TYPE SYNTAX INTEGER { bridgingEnabled(0), bridgingDisabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Bridging of Ethernet traffic from Second Data Service has been disabled because the wireless link is not operating at the configured Lowest Second Data Modulation Mode" ::= { alarms 24 } transparentClockSourcePortAlarm OBJECT-TYPE SYNTAX INTEGER { ok(0), invalidTransparentClockSourcePort(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Transparent Clock will not function properly because SFP, the selected clock source port is not FIBER" ::= { alarms 25 } -- Smtp group attribute definitions -- sMTPEmailAlert OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Simple Mail Transfer Protocol is used to send equipment alerts via email to a specified email address" ::= { smtp 1 } sMTPServerPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Port number of the SMTP server" ::= { smtp 3 } sMTPSourceEmailAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The 'from' email address used when constructing the automatically generated e-mail message" ::= { smtp 4 } sMTPDestinationEmailAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The 'to' email address used when constructing the automatically generated e-mail message" ::= { smtp 5 } sMTPEnabledMessages OBJECT-TYPE SYNTAX BITS { nIDULanPortUpDown(0), sFPPortUpDown(1), auxPortUpDown(2), mainPSUPortUpDown(3), enabledDiagnosticAlarms(4), dFSImpulseInterference(5), channelChange(6), wirelessLinkUpDown(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls which SMTP messages the unit will send" ::= { smtp 6 } sMTPServerInternetAddressType OBJECT-TYPE SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), unknown6(5), unknown7(6), unknown8(7), unknown9(8), unknown10(9), unknown11(10), unknown12(11), unknown13(12), unknown14(13), unknown15(14), unknown16(15), dns(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of Internet address specified by the associated sMTPServerInternetAddress." ::= { smtp 7 } sMTPServerInternetAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Internet address of the SMTP server" ::= { smtp 8 } -- SnmpControl group attribute definitions -- sNMPPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The IP port number used to access the SNMP MIB (i.e. Gets and Sets) (default = 161). NB: A system reboot is required to activate changes to this attribute" ::= { snmpControl 1 } sNMPCommunityString OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The SNMP community string. NB: A system reboot is required to activate changes to this attribute" ::= { snmpControl 2 } sNMPTrapTableNumber OBJECT-TYPE SYNTAX INTEGER (2) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the sNMPTrapTable." ::= { snmpControl 3 } sNMPTrapVersion OBJECT-TYPE SYNTAX INTEGER { v1(0), v2c(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The SNMP protocol version to use for SNMP Traps. NB: A system reboot is required to activate changes to this attribute" ::= { snmpControl 5 } sNMPEnabledTraps OBJECT-TYPE SYNTAX BITS { auxPortUpDown(0), mainPSUPortUpDown(1), authenticationFailure(2), enabledDiagnosticAlarms(3), dFSImpulseInterference(4), channelChange(5), wirelessLinkUpDown(6), coldStart(7), nIDULanPortUpDown(14), sFPPortUpDown(15) } MAX-ACCESS read-write STATUS current DESCRIPTION "This controls which SNMP Traps the unit will send" ::= { snmpControl 6 } enabledDiagnosticAlarms OBJECT-TYPE SYNTAX BITS { portState(0), incompatibleMasterAndSlave(1), incompatibleRegulatoryBands(2), maximumLinkRangeExceeded(3), unitOutOfCalibration(4), installArmState(5), installStatus(6), regulatoryBand(7), syslogLocalWrapped(8), syslogLocalNearlyFull(9), syslogDisabledWarning(10), linkModeOptimizationMismatch(11), tDDSynchronizationAlarm(12), wirelessLinkDisabledWarning(13), sNTPSynchronizationFailed(14), noWirelessChannelAvailable(15), tDMAlarms(18), capacityVariantMismatch(19), remainingFullCapacityTrialTime(20), dataBridgingStatus(21), unknown18(22), syslogClientDisabledWarning(23) } MAX-ACCESS read-write STATUS current DESCRIPTION "Controls which individual diagnostic alarms are enabled. The unit may be configured to generate SNMP traps and/or SMTP email alerts for these enabled alarms by selecting 'Enabled Diagnostic Alarms' on the 'SNMP Enabled Traps' and/or 'SMTP Enabled Messages' attributes" ::= { snmpControl 7 } sNMPSendAllTrapsAtStartup OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether cleared traps are reported at start-up as well as raised traps. Only enabled traps will be reported. NB: Traps corresponding to transient events (i.e. not associated with an alarm or status value) are only sent when required and not at start-up." ::= { snmpControl 8 } -- SNMPTrapTable group attribute definitions -- sNMPTrapTableIndex OBJECT-TYPE SYNTAX INTEGER (1..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "SNMP trap value, used to index the SNMPTrapTable." ::= { sNMPTrapTableEntry 1 } sNMPTrapPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Destination port for SNMP Traps (default=162). NB: A system reboot is required to activate changes to this attribute." ::= { sNMPTrapTableEntry 3 } sNMPTrapInternetAddressType OBJECT-TYPE SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), unknown6(5), unknown7(6), unknown8(7), unknown9(8), unknown10(9), unknown11(10), unknown12(11), unknown13(12), unknown14(13), unknown15(14), unknown16(15), dns(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of Internet address specified by the associated sNMPTrapInternetAddress." ::= { sNMPTrapTableEntry 4 } sNMPTrapInternetAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The Internet address to which all SNMP Traps are sent." ::= { sNMPTrapTableEntry 5 } sNMPTrapReceiverEnabled OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "A value of 0 disables the sending of SNMP trap to corresponding receiver. A value of 1 enables the sending of SNMP trap to corresponding receiver." ::= { sNMPTrapTableEntry 6 } -- Sntp group attribute definitions -- sNTPState OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "SNTP control state" ::= { sntp 1 } sNTPPollInterval OBJECT-TYPE SYNTAX INTEGER (60..43200) MAX-ACCESS read-write STATUS current DESCRIPTION "The SNTP server polling interval" ::= { sntp 4 } sNTPSync OBJECT-TYPE SYNTAX INTEGER { noSync(0), inSync(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "If SNTP Sync fails then check the server settings in the Remote Management page, or disable SNTP" ::= { sntp 5 } sNTPLastSync OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Last SNTP sync time" ::= { sntp 6 } systemClock OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "System clock presented as local time" ::= { sntp 7 } timeZone OBJECT-TYPE SYNTAX INTEGER { gmtMinus1200(0), gmtMinus1130(1), gmtMinus1100(2), gmtMinus1030(3), gmtMinus1000(4), gmtMinus0930(5), gmtMinus0900(6), gmtMinus0830(7), gmtMinus0800(8), gmtMinus0730(9), gmtMinus0700(10), gmtMinus0630(11), gmtMinus0600(12), gmtMinus0530(13), gmtMinus0500(14), gmtMinus0430(15), gmtMinus0400(16), gmtMinus0330(17), gmtMinus0300(18), gmtMinus0230(19), gmtMinus0200(20), gmtMinus0130(21), gmtMinus0100(22), gmtMinus0030(23), gmtZero(24), gmtPlus0030(25), gmtPlus0100(26), gmtPlus0130(27), gmtPlus0200(28), gmtPlus0230(29), gmtPlus0300(30), gmtPlus0330(31), gmtPlus0400(32), gmtPlus0430(33), gmtPlus0500(34), gmtPlus0530(35), gmtPlus0600(36), gmtPlus0630(37), gmtPlus0700(38), gmtPlus0730(39), gmtPlus0800(40), gmtPlus0830(41), gmtPlus0900(42), gmtPlus0930(43), gmtPlus1000(44), gmtPlus1030(45), gmtPlus1100(46), gmtPlus1130(47), gmtPlus1200(48), gmtPlus1230(49), gmtPlus1300(50) } MAX-ACCESS read-write STATUS current DESCRIPTION "Time zone offsets from Greenwich Mean Time (GMT)" ::= { sntp 8 } daylightSaving OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Daylight Saving Time" ::= { sntp 9 } sNTPPrimaryServer OBJECT-TYPE SYNTAX INTEGER { server1(0), server2(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the primary SNTP server, determining the order in which the servers are tried." ::= { sntp 10 } sNTPPrimaryServerDeadTime OBJECT-TYPE SYNTAX INTEGER (0..86400) MAX-ACCESS read-write STATUS current DESCRIPTION "Time (in seconds) to wait before retrying communications with an unresponsive primary SNTP server. Setting the value to 0 disables the timer." ::= { sntp 11 } sNTPServerRetries OBJECT-TYPE SYNTAX INTEGER (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of times the PTP will retry after an SNTP server fails to respond." ::= { sntp 12 } sNTPServerTimeout OBJECT-TYPE SYNTAX INTEGER (1..15) MAX-ACCESS read-write STATUS current DESCRIPTION "Time (in seconds) the PTP will wait for a response from an SNTP server." ::= { sntp 13 } sNTPServerTableNumber OBJECT-TYPE SYNTAX INTEGER (2) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the SNTPServerTable." ::= { sntp 14 } -- SNTPServerTable group attribute definitions -- sNTPServerTableIndex OBJECT-TYPE SYNTAX INTEGER (1..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index range for the SNTPServerTable." ::= { sNTPServerTableEntry 1 } sNTPServerPortNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The IP port number of the SNTP server. Defaults to port 123." ::= { sNTPServerTableEntry 3 } sNTPServerStatus OBJECT-TYPE SYNTAX DisplayString (SIZE(0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Status message reflecting the result of communications with the SNTP server when last polled" ::= { sNTPServerTableEntry 4 } sNTPServerInternetAddressType OBJECT-TYPE SYNTAX INTEGER { unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), unknown6(5), unknown7(6), unknown8(7), unknown9(8), unknown10(9), unknown11(10), unknown12(11), unknown13(12), unknown14(13), unknown15(14), unknown16(15), dns(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of Internet address specified by the associated sNTPServerInternetAddress." ::= { sNTPServerTableEntry 5 } sNTPServerInternetAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The Internet address of a valid SNTP server" ::= { sNTPServerTableEntry 6 } -- Reset group attribute definitions -- systemReset OBJECT-TYPE SYNTAX INTEGER { running(0), consoleReboot(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to '1' will cause a system reboot. NB: a system reboot will apply any pending new settings held in memory" ::= { reset 1 } -- Versions group attribute definitions -- softwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Current software version" ::= { versions 1 } hardwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware platform version" ::= { versions 2 } secondarySoftwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Secondary software version, used when the primary software image is invalid or erased" ::= { versions 3 } bootVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Boot code software version" ::= { versions 4 } -- PubStats group attribute definitions -- receiveDataRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average data rate over the last one second interval (kbps)" ::= { pubStats 1 } transmitDataRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average data rate over the last one second interval (kbps)" ::= { pubStats 2 } aggregateDataRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average data rate over the last one second interval (kbps)" ::= { pubStats 3 } wirelessLinkAvailability OBJECT-TYPE SYNTAX INTEGER (0..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "Link availability calculated since the last reset of the system counters, as a percentage multiplied by 10000 to give four decimal places of precision" ::= { pubStats 4 } wirelessLinkStatus OBJECT-TYPE SYNTAX INTEGER { up(0), registering(1), searching(2), acquiring(3), radarCAC(4), initialising(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of the wireless link" ::= { pubStats 5 } byteErrorRatio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Reciprocal of the byte error ratio calculated since the last reset of the system counters" ::= { pubStats 6 } receiveModulationModeDetail OBJECT-TYPE SYNTAX INTEGER { runningAtMaximumReceiveMode(0), runningAtUserConfiguredMaxModulationMode(1), restrictedBecauseInstallationIsArmed(2), restrictedBecauseOfByteErrorsOnTheWirelessLink(3), restrictedBecauseTheLinkParametersAreUpdating(4), restrictedBecauseChannelChangeIsInProgress(5), restrictedDueToTheLowEthernetLinkSpeed(6), runningAtMaximumReceiveModeForChannelBandwidth(7), limitedByTheWirelessConditions(8), restrictedBecauseFullCapabilityTrialLicenseExpired(9) } MAX-ACCESS read-only STATUS current DESCRIPTION "The reason for the current receive modulation mode" ::= { pubStats 7 } dataBridgingAvailability OBJECT-TYPE SYNTAX INTEGER (0..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "Link availability bridging Ethernet Data traffic calculated since the last reset of the system counters, as a percentage multiplied by 10000 to give four decimal places of precision" ::= { pubStats 8 } -- Encryption group attribute definitions -- encryptionAlgorithm OBJECT-TYPE SYNTAX INTEGER { none(0), aESRijndael(1), aES192bitRijndael(2), aES256bitRijndael(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Encryption Algorithm used by the wireless link. NB: A system reboot is required to activate changes to this attribute. NB: The same Encryption Algorithm must be configured at BOTH ends of the link for it to function correctly" ::= { encryption 1 } -- TDDControl group attribute definitions -- tDDSynchronizationMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "TDD Synchronization Mode selection" ::= { tDDControl 1 } -- AAAControl group attribute definitions -- userTableNumber OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of entries in the userTable" ::= { aAAControl 1 } -- UserTable group attribute definitions -- userTableIndex OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS not-accessible STATUS current DESCRIPTION "used to index values in the userTable." ::= { userTableEntry 1 } userName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..67)) MAX-ACCESS read-only STATUS current DESCRIPTION "User name which must be entered, along with the appropriate password, in order to gain access to the system." ::= { userTableEntry 2 } userRole OBJECT-TYPE SYNTAX INTEGER { readOnly(0), systemAdministrator(1), securityOfficer(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Role of the selected user. A Security Officer has access to and can modify all settings. A System Administrator has access to and can modify all non-security settings. A Read Only user can view settings, but cannot make any changes." ::= { userTableEntry 3 } userEnabled OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable / Disable the selected user" ::= { userTableEntry 4 } userPassword OBJECT-TYPE SYNTAX DisplayString (SIZE(0..67)) MAX-ACCESS read-write STATUS current DESCRIPTION "User password, which must be entered in order to gain access to the system." ::= { userTableEntry 5 } -- SyslogControl group attribute definitions -- syslogClient OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable the syslog client" ::= { syslogControl 1 } syslogState OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The syslog service has been enabled or disabled" ::= { syslogControl 2 } -- RouterProtocols group attribute definitions -- microwaveAdaptiveBandwidth OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable support of Microwave Adaptive Bandwidth Protocol. MAB is disabled if link symmetry is configured as Adaptive" ::= { routerProtocols 1 } mABNominalModulationMode OBJECT-TYPE SYNTAX INTEGER { modAcquisition(0), modBpsk63percent(1), modQpsk63percentSingle(2), modTransient1(3), modQpsk87percentSingle(4), modTransient2(5), mod16qam63percentSingleA(6), modTransient3(7), mod16qam87percentSingle(8), modTransient4(9), mod64qam75percentSingle(10), modTransient5(11), mod64qam92percentSingle(12), modTransient6(13), mod256qam81percentSingle(14), mod16qam63percentSingleB(15), mod16qam63percentDual(16), modTransient7(17), mod16qam87percentDual(18), modTransient8(19), mod64qam75percentDual(20), modTransient9(21), mod64qam92percentDual(22), modTransient10(23), mod256qam81percentDual(24) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Nominal modulation mode is the desired modulation mode. MAB VSM packets are generated when the current modulation mode falls below the nominal modulation." ::= { routerProtocols 2 } mABTransmissionInterval OBJECT-TYPE SYNTAX INTEGER { transmissionInterval1s(0), transmissionInterval10s(1), transmissionInterval60s(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum interval (in seconds) between successive MAB vendor specific messages (VSM). These VSM are sent when the current transmit capacity falls below the configured MAB Nominal Modulation Mode." ::= { routerProtocols 3 } mABHoldoffPeriod OBJECT-TYPE SYNTAX INTEGER (10..60) MAX-ACCESS read-only STATUS current DESCRIPTION "The period (in seconds) over which transmit capacity is averaged over to determine when the wireless link has degraded" ::= { routerProtocols 4 } mABMaintenanceLevel OBJECT-TYPE SYNTAX INTEGER (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Levels (0-7) determines the destination MAC address of MAB vendor specific messages." ::= { routerProtocols 5 } useVLANForMABProtocol OBJECT-TYPE SYNTAX INTEGER { noVLANTagging(0), iEEE8021QTaggedCTagType8100(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This controls whether MAB vendor specific messages (VSM) packets use VLAN tags or not." ::= { routerProtocols 6 } mABProtocolVID OBJECT-TYPE SYNTAX INTEGER (0..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "This VLAN VID (0-4094) will be included in MAB vendor specific messages (VSM) packets." ::= { routerProtocols 7 } mABProtocolVLANPriority OBJECT-TYPE SYNTAX INTEGER (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "This VLAN Priority (0-7) will be included in MAB vendor specific messages (VSM) packets." ::= { routerProtocols 8 } mABState OBJECT-TYPE SYNTAX INTEGER { normal(0), degraded(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current state of MAB Protocol. A state of 'Normal' on a green background indicates that a PTP link is operating at nominal capacity" ::= { routerProtocols 9 } mABNominalTransmitCapacity OBJECT-TYPE SYNTAX INTEGER (0..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "The nominal Tx capacity used in MAB Vendor Specific Messages for the selected nominal modulation mode " ::= { routerProtocols 10 } mABCurrentTransmitCapacity OBJECT-TYPE SYNTAX INTEGER (0..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "The current Tx capacity of the wireless link used in the last MAB Vendor Specific Message transmitted." ::= { routerProtocols 11 } -- CableDiagnostics group attribute definitions -- cableDiagnosticsPorts OBJECT-TYPE SYNTAX BITS { auxPort(6), mainPSUPort(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Select ports on which Cable Diagnostics must be executed" ::= { cableDiagnostics 1 } cableDiagnosticsControl OBJECT-TYPE SYNTAX INTEGER { startTest(0), testInProgress(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set this attribute to 'Test in Progress' to start a Cable Diagnostics test" ::= { cableDiagnostics 2 } cableDiagnosticsWarning OBJECT-TYPE SYNTAX INTEGER { idle(0), testInProgress(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Normal Ethernet operation is disrupted when a Cable Diagnostics test is in progress" ::= { cableDiagnostics 3 } cableDiagnosticsResultTableNumber OBJECT-TYPE SYNTAX INTEGER (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of rows in the Cable Diagnostics Result Table." ::= { cableDiagnostics 4 } -- CableDiagnosticsResultTable group attribute definitions -- cableDiagnosticsResultTableIndex OBJECT-TYPE SYNTAX INTEGER (1..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Cable Diagnostics Port value used to index into the result table." ::= { cableDiagnosticsResultTableEntry 1 } cableDiagnosticsResultsDateTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Date and Time when a Cable Diagnostics test was last executed" ::= { cableDiagnosticsResultTableEntry 2 } cableDiagPair1Results OBJECT-TYPE SYNTAX INTEGER { ok(0), unknown(1), inProgress(2), notTested(3), openCircuit(4), shortCircuit(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The result of the most recent execution of Cable Diagnostics on cable pair 1. According to the T658B wiring scheme, pair 1 is pins 4 & 5 on the RJ45 socket on the ODU. Open Circuit is reported when the impedance is greater than 330 ohms. Short Circuit is reported when the impedance is less than 33 ohms. Unknown is reported when a continuous signal is received from the link partner for 125 ms, preventing start of the test." ::= { cableDiagnosticsResultTableEntry 3 } cableDiagPair1Distance OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The distance in meters from the ODU to the fault detected on the cable pair during the most recent execution of Cable Diagnostics. Faults in cables longer than 160 meters (525 feet) may not be detected. The error margin is +/-2 meters (6.5 feet)." ::= { cableDiagnosticsResultTableEntry 4 } cableDiagPair2Results OBJECT-TYPE SYNTAX INTEGER { ok(0), unknown(1), inProgress(2), notTested(3), openCircuit(4), shortCircuit(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The result of the most recent execution of Cable Diagnostics on cable pair 2. According to the T658B wiring scheme, pair 2 is pins 1 & 2 on the RJ45 socket on the ODU. Open Circuit is reported when the impedance is greater than 330 ohms. Short Circuit is reported when the impedance is less than 33 ohms. Unknown is reported when a continuous signal is received from the link partner for 125 ms, preventing start of the test." ::= { cableDiagnosticsResultTableEntry 5 } cableDiagPair2Distance OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The distance in meters from the ODU to the fault detected on the cable pair during the most recent execution of Cable Diagnostics. Faults in cables longer than 160 meters (525 feet) may not be detected. The error margin is +/-2 meters (6.5 feet)." ::= { cableDiagnosticsResultTableEntry 6 } cableDiagPair3Results OBJECT-TYPE SYNTAX INTEGER { ok(0), unknown(1), inProgress(2), notTested(3), openCircuit(4), shortCircuit(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The result of the most recent execution of Cable Diagnostics on cable pair 3. According to the T658B wiring scheme, pair 3 is pins 3 & 6 on the RJ45 socket on the ODU. Open Circuit is reported when the impedance is greater than 330 ohms. Short Circuit is reported when the impedance is less than 33 ohms. Unknown is reported when a continuous signal is received from the link partner for 125 ms, preventing start of the test." ::= { cableDiagnosticsResultTableEntry 7 } cableDiagPair3Distance OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The distance in meters from the ODU to the fault detected on the cable pair during the most recent execution of Cable Diagnostics. Faults in cables longer than 160 meters (525 feet) may not be detected. The error margin is +/-2 meters (6.5 feet)." ::= { cableDiagnosticsResultTableEntry 8 } cableDiagPair4Results OBJECT-TYPE SYNTAX INTEGER { ok(0), unknown(1), inProgress(2), notTested(3), openCircuit(4), shortCircuit(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The result of the most recent execution of Cable Diagnostics on cable pair 4. According to the T658B wiring scheme, pair 4 is pins 7 & 8 on the RJ45 socket on the ODU. Open Circuit is reported when the impedance is greater than 330 ohms. Short Circuit is reported when the impedance is less than 33 ohms. Unknown is reported when a continuous signal is received from the link partner for 125 ms, preventing start of the test." ::= { cableDiagnosticsResultTableEntry 9 } cableDiagPair4Distance OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The distance in meters from the ODU to the fault detected on the cable pair during the most recent execution of Cable Diagnostics. Faults in cables longer than 160 meters (525 feet) may not be detected. The error margin is +/-2 meters (6.5 feet)." ::= { cableDiagnosticsResultTableEntry 10 } -- Supplementary group attribute definitions -- longitude OBJECT-TYPE SYNTAX DisplayString (SIZE(0..19)) MAX-ACCESS read-write STATUS current DESCRIPTION "The longitude of the unit, measured in decimal degrees. This object is set by the SNMP manager and has no internal function." ::= { supplementary 1 } latitude OBJECT-TYPE SYNTAX DisplayString (SIZE(0..19)) MAX-ACCESS read-write STATUS current DESCRIPTION "The latitude of the unit, measured in decimal degrees. This object is set by the SNMP manager and has no internal function." ::= { supplementary 2 } altitude OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The altitude of the unit, measured in meters. This object is set by the SNMP manager and has no internal function." ::= { supplementary 3 } -- Enterprise NOTIFICATION definitions -- channelChangeTrap NOTIFICATION-TYPE OBJECTS { receiveChannel } STATUS current DESCRIPTION "The PTP radio has changed wireless channel. This has been caused by either i) mandatory radar avoidance, a DFS impulsive interference event will also be detected, or ii) Dynamic Spectrum Optimization, (DSO) DSO improves link performance by selecting the most appropriate transmit and receive channels with the lowest level of interference." ::= { ptpTrapPrefix 1 } dfsImpulsiveInterferenceTrap NOTIFICATION-TYPE OBJECTS { receiveChannel } STATUS current DESCRIPTION "DFS impulsive interference detected event" ::= { ptpTrapPrefix 2 } mainPSUPortStatusTrap NOTIFICATION-TYPE OBJECTS { mainPSUPortStatus } STATUS current DESCRIPTION "Current status of the Main PSU Ethernet link. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 3 } mainPSUPortDisabledWarningTrap NOTIFICATION-TYPE OBJECTS { mainPSUPortDisabledWarning } STATUS current DESCRIPTION "The SNMP ifAdminStatus of the interface has disabled Ethernet traffic" ::= { ptpTrapPrefix 4 } mainPSUPortConfigurationMismatchTrap NOTIFICATION-TYPE OBJECTS { mainPSUPortConfigurationMismatch } STATUS current DESCRIPTION "The detection of Ethernet fragments (runt packets) when the link is in full duplex is an indication of an auto-negotiation or forced configuration mismatch" ::= { ptpTrapPrefix 5 } auxPortStatusTrap NOTIFICATION-TYPE OBJECTS { auxPortStatus } STATUS current DESCRIPTION "Current status of the Aux Ethernet link. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 6 } auxPortDisabledWarningTrap NOTIFICATION-TYPE OBJECTS { auxPortDisabledWarning } STATUS current DESCRIPTION "The SNMP ifAdminStatus of the interface has disabled Ethernet traffic" ::= { ptpTrapPrefix 7 } regulatoryBandTrap NOTIFICATION-TYPE OBJECTS { regulatoryBand } STATUS current DESCRIPTION "The Regulatory Band prohibits the wireless unit from operating outside the regulated limits. An invalid Regulatory Band may be caused by a missing or incorrect License Key, a corrupt MAC Address or an attempt to configure a Regulatory Band not allowed by the License Key. NB: a change of state may generate an SNMP trap and/or SMTP email alert." ::= { ptpTrapPrefix 8 } installStatusTrap NOTIFICATION-TYPE OBJECTS { installStatus } STATUS current DESCRIPTION "A non-zero value indicates that signalling was received with the wrong MAC address or a mismatched link name. NB: It is very unusual to detect this, because units with mis-configured Target MAC Address will normally fail to establish a wireless link. However, rare circumstances may establish a partial wireless link and detect this situation. NB: A non-zero value on start-up, or a change of value during operation, may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 9 } installArmStateTrap NOTIFICATION-TYPE OBJECTS { installArmState } STATUS current DESCRIPTION "Indicates if the unit is being installed. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 10 } unitOutOfCalibrationTrap NOTIFICATION-TYPE OBJECTS { unitOutOfCalibration } STATUS current DESCRIPTION "The unit is out of calibration" ::= { ptpTrapPrefix 11 } auxPortPowerOverEthernetOutputStatusTrap NOTIFICATION-TYPE OBJECTS { auxPortPowerOverEthernetOutputStatus } STATUS current DESCRIPTION "Current status of the Power Over Ethernet (PoE) output of the Aux port" ::= { ptpTrapPrefix 12 } incompatibleRegulatoryBandsTrap NOTIFICATION-TYPE OBJECTS { incompatibleRegulatoryBands } STATUS current DESCRIPTION "The master and slave units have incompatible regulatory bands. NB: Both units must have compatible license keys" ::= { ptpTrapPrefix 14 } noWirelessChannelAvailableTrap NOTIFICATION-TYPE OBJECTS { noWirelessChannelAvailable } STATUS current DESCRIPTION "Spectrum Management was unable to locate a suitable wireless channel to operate on" ::= { ptpTrapPrefix 15 } wirelessLinkDisabledWarningTrap NOTIFICATION-TYPE OBJECTS { wirelessLinkDisabledWarning } STATUS current DESCRIPTION "The SNMP ifAdminStatus of the wireless interface has disabled wireless traffic" ::= { ptpTrapPrefix 16 } auxPortConfigurationMismatchTrap NOTIFICATION-TYPE OBJECTS { auxPortConfigurationMismatch } STATUS current DESCRIPTION "The detection of Ethernet fragments (runt packets) when the link is in full duplex is an indication of an auto-negotiation or forced configuration mismatch. This alarm is only raised if an Out-of-Band Management Mode has been configured." ::= { ptpTrapPrefix 17 } sFPErrorTrap NOTIFICATION-TYPE OBJECTS { sFPError } STATUS current DESCRIPTION "If the SFP link is not OK, there are five possible causes: Either a SFP has been installed but the license key does not include SFP fiber support, a fiber link could not be established even though no LOS was detected (i.e. an optical carrier was detected, which could be due to a broken TX fiber, or because the link is disabled at the fiber link partner), a fiber link could not be established and LOS is detected (i.e. no optical carrier is detected), the installed SFP is not supported or the installed SFP failed to initialize correctly. NB: a change of status may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 18 } sFPPortStatusTrap NOTIFICATION-TYPE OBJECTS { sFPPortStatus } STATUS current DESCRIPTION "Current status of the SFP Ethernet link. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 19 } incompatibleMasterAndSlaveTrap NOTIFICATION-TYPE OBJECTS { incompatibleMasterAndSlave } STATUS current DESCRIPTION "A non-zero value indicates that the master and slave ends of a link are different hardware products, or have different software versions. NB: It is very unusual to detect this, because incompatible units will normally fail to establish a wireless link. However, some combinations may establish a partial wireless link and detect this situation. NB: A non-zero value may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 20 } sNTPSyncTrap NOTIFICATION-TYPE OBJECTS { sNTPSync } STATUS current DESCRIPTION "If SNTP Sync fails then check the server settings in the Remote Management page, or disable SNTP" ::= { ptpTrapPrefix 21 } tDDSynchronizationAlarmTrap NOTIFICATION-TYPE OBJECTS { tDDSynchronizationAlarm } STATUS current DESCRIPTION "Not Synchronized indicates failure of the external timing system for a period greater than the holdover timer. TDD frame timing will have drifted, and this link may cause interference with other links in a synchronized network. Timing System Failure is an early warning, indicating that 80% of the holdover period has expired." ::= { ptpTrapPrefix 22 } sFPPortDisabledWarningTrap NOTIFICATION-TYPE OBJECTS { sFPPortDisabledWarning } STATUS current DESCRIPTION "The SNMP ifAdminStatus of the interface has disabled Ethernet traffic" ::= { ptpTrapPrefix 23 } sFPPortConfigurationMismatchTrap NOTIFICATION-TYPE OBJECTS { sFPPortConfigurationMismatch } STATUS current DESCRIPTION "The detection of Ethernet fragments (runt packets) when the link is in full duplex is an indication of an auto-negotiation or forced configuration mismatch. This alarm is only raised if an Out-of-Band Management Mode has been configured." ::= { ptpTrapPrefix 24 } linkModeOptimizationMismatchTrap NOTIFICATION-TYPE OBJECTS { linkModeOptimizationMismatch } STATUS current DESCRIPTION "The remote node of this link has been configured with a different link mode optimization" ::= { ptpTrapPrefix 25 } tDMInterfaceStatusTrap NOTIFICATION-TYPE OBJECTS { tDMInterfaceStatus } STATUS current DESCRIPTION "@Current status of the connection to the TDM Box. A state of 'Up' on a green background indicates that the TDM Box is connected OK. When connecting a TDM Box only the Main Ethernet port should be used" ::= { ptpTrapPrefix 26 } tDMChannelStatusTrap NOTIFICATION-TYPE OBJECTS { tDMChannelStatus } STATUS current DESCRIPTION "Current status of the TDM channels. A value of 0 indicates that a TDM channel is established" ::= { ptpTrapPrefix 27 } tDMChannelLoopbackTrap NOTIFICATION-TYPE OBJECTS { tDMChannelLoopback } STATUS current DESCRIPTION "The loopback status of TDM channels. This is intended for installation testing and should be set to 'None' for normal operation. The wire connections to a unit can be tested by applying a 'Copper' loopback to the local unit. The wireless connection to the remote unit can be tested by applying a 'Wireless' loopback to the remote unit with no loopback on the local unit. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 28 } nIDULanPortStatusTrap NOTIFICATION-TYPE OBJECTS { nIDULanPortStatus } STATUS current DESCRIPTION "Current status of the NIDU LAN Ethernet link. NB: a change of state may generate an SNMP trap and/or SMTP email alert" ::= { ptpTrapPrefix 29 } syslogStateTrap NOTIFICATION-TYPE OBJECTS { syslogState } STATUS current DESCRIPTION "The syslog service has been enabled or disabled" ::= { ptpTrapPrefix 30 } syslogLocalNearlyFullTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "The syslog local log is nearly full (90%)" ::= { ptpTrapPrefix 31 } syslogLocalWrappedTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "The syslog local log has wrapped" ::= { ptpTrapPrefix 32 } syslogClientTrap NOTIFICATION-TYPE OBJECTS { syslogClient } STATUS current DESCRIPTION "Enable or disable the syslog client" ::= { ptpTrapPrefix 33 } secureModeAlarmTrap NOTIFICATION-TYPE OBJECTS { secureModeAlarm } STATUS current DESCRIPTION "The secure mode (e.g. FIPS, UC-APL) state of the unit. The secure mode is not configured(1) state indicates that the unit is capable of secure mode operation, and one or more of the following security materials has not been configured: Key Of Keys, Private Key, Public Certificate, DRNG Entropy Status, Wireless Encryption Key. The secure mode mode is configured but not active(2) state indicates that the unit is capable of secure mode operation, and the security material has been configured, but the configuration of interfaces is not consistent with secure mode operation. The secure mode is not supported(3) state indicates that the unit is not capable of secure mode operation. The secure mode capability requires appropriate hardware compatibility, license key and software image." ::= { ptpTrapPrefix 34 } dataBridgingStatusAlarmTrap NOTIFICATION-TYPE OBJECTS { dataBridgingStatusAlarm } STATUS current DESCRIPTION "Ethernet Data traffic bridging is disabled because the wireless link is not operating at the configured Lowest Data Modulation Mode" ::= { ptpTrapPrefix 35 } licenseRemainingTrialPeriodAlarmTrap NOTIFICATION-TYPE OBJECTS { licenseRemainingTrialPeriodAlarm } STATUS current DESCRIPTION "If the full capability trial license period is about to expire then purchase a license upgrade from your reseller." ::= { ptpTrapPrefix 36 } capacityVariantMismatchTrap NOTIFICATION-TYPE OBJECTS { capacityVariantMismatch } STATUS current DESCRIPTION "The remote node of this link has a lower link capacity. Operating with a reduced effective link capacity." ::= { ptpTrapPrefix 37 } maxLinkRangeExceededTrap NOTIFICATION-TYPE OBJECTS { maxLinkRangeExceeded } STATUS current DESCRIPTION "The measured link range is greater than the maximum allowed by the license key. The link will operate at a reduced capacity while this condition applies. This alarm is only raised if the license specifies a maximum link range and the trial license is not active." ::= { ptpTrapPrefix 38 } tDMConfigurationMismatchTrap NOTIFICATION-TYPE OBJECTS { tDMConfigurationMismatch } STATUS current DESCRIPTION "Current status of the configuration of the TDM Box. A state of 'Ok' on a green background indicates that the TDM Box configuration is matched OK with the remote end." ::= { ptpTrapPrefix 39 } nIDULanPortDisabledWarningTrap NOTIFICATION-TYPE OBJECTS { nIDULanPortDisabledWarning } STATUS current DESCRIPTION "The SNMP ifAdminStatus of the interface has disabled Ethernet traffic" ::= { ptpTrapPrefix 40 } nIDULanPortConfigurationMismatchTrap NOTIFICATION-TYPE OBJECTS { nIDULanPortConfigurationMismatch } STATUS current DESCRIPTION "The detection of Ethernet fragments (runt packets) when the link is in full duplex is an indication of an auto-negotiation or forced configuration mismatch." ::= { ptpTrapPrefix 41 } secondDataBridgingStatusAlarmTrap NOTIFICATION-TYPE OBJECTS { secondDataBridgingStatusAlarm } STATUS current DESCRIPTION "Bridging of Ethernet traffic from Second Data Service has been disabled because the wireless link is not operating at the configured Lowest Second Data Modulation Mode" ::= { ptpTrapPrefix 42 } transparentClockSourcePortAlarmTrap NOTIFICATION-TYPE OBJECTS { transparentClockSourcePortAlarm } STATUS current DESCRIPTION "Transparent Clock will not function properly because SFP, the selected clock source port is not FIBER" ::= { ptpTrapPrefix 43 } portAllocationMismatchTrap NOTIFICATION-TYPE OBJECTS { portAllocationMismatch } STATUS current DESCRIPTION "The local and remote ODUs have different services configured." ::= { ptpTrapPrefix 44 } END