NSCRTV-HFCEMS-OPTICALAMPLIFIER-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB oaIdent FROM NSCRTV-ROOT ; oaVendorOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS optional DESCRIPTION "" ::= { oaIdent 1 } oaOutputOpticalPower OBJECT-TYPE SYNTAX INTEGER ( 0..65535 ) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { oaIdent 2 } oaInputOpticalPower OBJECT-TYPE SYNTAX INTEGER ( -128..127 ) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { oaIdent 3 } oaPumpTable OBJECT-TYPE SYNTAX SEQUENCE OF OaPumpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { oaIdent 4 } oaPumpEntry OBJECT-TYPE SYNTAX OaPumpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { oaPumpIndex } ::= { oaPumpTable 1 } OaPumpEntry ::= SEQUENCE { oaPumpIndex INTEGER, oaPumpBIAS INTEGER, oaPumpTEC INTEGER, oaPumpTemp INTEGER } oaPumpIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { oaPumpEntry 1 } oaPumpBIAS OBJECT-TYPE SYNTAX INTEGER ( 0..65535 ) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { oaPumpEntry 2 } oaPumpTEC OBJECT-TYPE SYNTAX INTEGER ( -32768..32767 ) ACCESS read-only STATUS optional DESCRIPTION "" ::= { oaPumpEntry 3 } oaPumpTemp OBJECT-TYPE SYNTAX INTEGER ( 0..32768 ) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { oaPumpEntry 4 } oaNumberDCPowerSupply OBJECT-TYPE SYNTAX INTEGER ( 0..16 ) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { oaIdent 5 } oaDCPowerSupplyMode OBJECT-TYPE SYNTAX INTEGER { loadsharing(1), switchedRedundant(2),aloneSupply(3) } ACCESS read-only STATUS optional DESCRIPTION " " ::= { oaIdent 6 } oaDCPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF OaDCPowerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { oaIdent 7 } oaDCPowerEntry OBJECT-TYPE SYNTAX OaDCPowerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { oaDCPowerIndex } ::= { oaDCPowerTable 1 } OaDCPowerEntry ::= SEQUENCE { oaDCPowerIndex INTEGER, oaDCPowerVoltage INTEGER, oaDCPowerCurrent INTEGER, oaDCPowerName DisplayString } oaDCPowerIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { oaDCPowerEntry 1 } oaDCPowerVoltage OBJECT-TYPE SYNTAX INTEGER ( -32768..32767 ) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { oaDCPowerEntry 2 } oaDCPowerCurrent OBJECT-TYPE SYNTAX INTEGER ( 0..65535 ) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { oaDCPowerEntry 3 } oaDCPowerName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { oaDCPowerEntry 4 } oaVendorExtend OBJECT IDENTIFIER ::= { oaIdent 8 } AdminEDFAIP OBJECT IDENTIFIER ::= { oaVendorExtend 13 } edfaIPNetTabNum OBJECT IDENTIFIER ::= { AdminEDFAIP 1 } edfaIPTable OBJECT IDENTIFIER ::= { AdminEDFAIP 2 } oaPumpNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "" ::= { oaVendorExtend 1 } oaOutputPowerSet OBJECT-TYPE SYNTAX INTEGER ( 0..4000 ) ACCESS read-write STATUS optional DESCRIPTION "" ::= { oaVendorExtend 2 } oaOutputPowerSetValueMax OBJECT-TYPE SYNTAX INTEGER ( 0..4000 ) ACCESS read-only STATUS optional DESCRIPTION "" ::= { oaVendorExtend 3 } oaOutputPowerSetValueMin OBJECT-TYPE SYNTAX INTEGER ( 0..4000 ) ACCESS read-only STATUS optional DESCRIPTION "" ::= { oaVendorExtend 4 } oaFansState OBJECT-TYPE SYNTAX INTEGER { on(1), off(2)} ACCESS read-only STATUS optional DESCRIPTION "" ::= { oaVendorExtend 5 } oaFansControl OBJECT-TYPE SYNTAX INTEGER { on(1), off(2), auto(3) } ACCESS read-write STATUS optional DESCRIPTION "" ::= { oaVendorExtend 6 } oaInputOpticalPower2 OBJECT-TYPE SYNTAX INTEGER ( -2000..2000 ) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { oaVendorExtend 7 } oaOpticalOutputNum OBJECT-TYPE SYNTAX INTEGER ( -128..127 ) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { oaVendorExtend 8 } oaABControl OBJECT-TYPE SYNTAX INTEGER { Auto(1), M(2)} ACCESS read-only STATUS optional DESCRIPTION "" ::= { oaVendorExtend 9 } oaDSControl OBJECT-TYPE SYNTAX INTEGER { CH(1), CH(2)} ACCESS read-only STATUS optional DESCRIPTION "" ::= { oaVendorExtend 10 } oaABState OBJECT-TYPE SYNTAX INTEGER { CH(1), CH(2)} ACCESS read-only STATUS optional DESCRIPTION "" ::= { oaVendorExtend 11 } oaEDFAAlarmRangeTable OBJECT-TYPE SYNTAX SEQUENCE OF OaEDFAAlarmRangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { oaVendorExtend 12 } oaEDFAAlarmRangeEntry OBJECT-TYPE SYNTAX OaEDFAAlarmRangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { oaEDFAAlarmRangeIndex } ::= { oaEDFAAlarmRangeTable 1 } OaEDFAAlarmRangeEntry ::= SEQUENCE { oaEDFAAlarmRangeIndex INTEGER, oaEDFAAlarmRangeDecr OCTET STRING, oaEDFAAlarmRangeHIHItoHI INTEGER, oaEDFAAlarmRangeHIHItoLO INTEGER, oaEDFAAlarmRangeHItoHI INTEGER, oaEDFAAlarmRangeHItoLO INTEGER, oaEDFAAlarmRangeLOtoHI INTEGER, oaEDFAAlarmRangeLOtoLO INTEGER, oaEDFAAlarmRangeLOLOtoHI INTEGER, oaEDFAAlarmRangeLOLOtoLO INTEGER, oaEDFAAlarmRangeDDtoHI INTEGER, oaEDFAAlarmRangeDDtoLO INTEGER } oaEDFAAlarmRangeIndex OBJECT-TYPE SYNTAX INTEGER (1..12) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { oaEDFAAlarmRangeEntry 1 } oaEDFAAlarmRangeDecr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS mandatory DESCRIPTION "Description." ::= { oaEDFAAlarmRangeEntry 2 } oaEDFAAlarmRangeHIHItoHI OBJECT-TYPE SYNTAX INTEGER ( -32768..32767 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { oaEDFAAlarmRangeEntry 3 } oaEDFAAlarmRangeHIHItoLO OBJECT-TYPE SYNTAX INTEGER ( -32768..32767 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { oaEDFAAlarmRangeEntry 4 } oaEDFAAlarmRangeHItoHI OBJECT-TYPE SYNTAX INTEGER ( -32768..32767 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { oaEDFAAlarmRangeEntry 5 } oaEDFAAlarmRangeHItoLO OBJECT-TYPE SYNTAX INTEGER ( -32768..32767 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { oaEDFAAlarmRangeEntry 6 } oaEDFAAlarmRangeLOtoHI OBJECT-TYPE SYNTAX INTEGER ( -32768..32767 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { oaEDFAAlarmRangeEntry 7 } oaEDFAAlarmRangeLOtoLO OBJECT-TYPE SYNTAX INTEGER ( -32768..32767 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { oaEDFAAlarmRangeEntry 8 } oaEDFAAlarmRangeLOLOtoHI OBJECT-TYPE SYNTAX INTEGER ( -32768..32767 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { oaEDFAAlarmRangeEntry 9 } oaEDFAAlarmRangeLOLOtoLO OBJECT-TYPE SYNTAX INTEGER ( -32768..32767 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { oaEDFAAlarmRangeEntry 10 } oaEDFAAlarmRangeDDtoHI OBJECT-TYPE SYNTAX INTEGER ( -32768..32767 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { oaEDFAAlarmRangeEntry 11 } oaEDFAAlarmRangeDDtoLO OBJECT-TYPE SYNTAX INTEGER ( -32768..32767 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { oaEDFAAlarmRangeEntry 12 } edfaIPNetTabNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { AdminEDFAIP 1 } edfaIPTable OBJECT-TYPE SYNTAX SEQUENCE OF EdfaNetIPEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { AdminEDFAIP 2 } EdfaNetIPEntry OBJECT-TYPE SYNTAX EdfaNetIPEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { MachineNetIpIndex } ::= { edfaIPTable 1 } EdfaNetIPEntry ::= SEQUENCE { MachineNetIpIndex INTEGER, MachineNetIpDecr DisplayString, MachineNetIpMessg IpAddress } MachineNetIpIndex OBJECT-TYPE SYNTAX INTEGER ( 0..10 ) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { EdfaNetIPEntry 1 } MachineNetIpDecr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { EdfaNetIPEntry 2 } MachineNetIpMessg OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { EdfaNetIPEntry 3 } END