-- -- CIENA-WS-NOTIFICATION-MIB.my -- CIENA-WS-NOTIFICATION-MIB DEFINITIONS ::= BEGIN IMPORTS Unsigned32, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, OBJECT-IDENTITY FROM SNMPv2-SMI cienaWsNotifications FROM CIENA-WS-MIB TEXTUAL-CONVENTION FROM SNMPv2-TC; cienaWsNotificationMIB MODULE-IDENTITY LAST-UPDATED "201801150000Z" ORGANIZATION "Ciena Corporation" CONTACT-INFO "Web URL: http://www.ciena.com/ Postal: 7035 Ridge Road Hanover, Maryland 21076 U.S.A. Phone: +1 800-921-1144 Fax: +1 410-694-5750" DESCRIPTION "Notification definitions for Waveserver. Contains alarm notifications and link state defects." REVISION "201801150000Z" DESCRIPTION "Updates wsAlarmNotificationActiveStatus from TruthValue to include active(1), inactive(2), and intermittent(3) states" REVISION "201611140000Z" DESCRIPTION "Added MODULE-IDENTITY statements." ::= { cienaWsNotifications 3 } -- Textual conventions DisplayString32 ::= TEXTUAL-CONVENTION DISPLAY-HINT "32t" STATUS current DESCRIPTION "A UTF-8 string with a max length of 32 characters" SYNTAX OCTET STRING(SIZE(1..32)) -- Alarm Notifications wsAlarmNotification NOTIFICATION-TYPE OBJECTS { wsAlarmNotificationSiteId, wsAlarmNotificationGroupId, wsAlarmNotificationMemberId, wsAlarmNotificationInstanceId, wsAlarmNotificationDateAndTime, wsAlarmNotificationTableId, wsAlarmNotificationSeverity, wsAlarmNotificationInstance, wsAlarmNotificationDescription, wsAlarmNotificationActiveStatus, wsAlarmNotificationEntityType } STATUS current DESCRIPTION "Ciena Wavesever notification for an alarm raising or clearing" ::= { cienaWsNotifications 11 } wsAlarmNotificationSiteId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The system Site ID." ::= { wsAlarmNotification 1 } wsAlarmNotificationGroupId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The system Group ID." ::= { wsAlarmNotification 2 } wsAlarmNotificationMemberId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The system Member ID." ::= { wsAlarmNotification 3 } wsAlarmNotificationInstanceId OBJECT-TYPE SYNTAX Unsigned32(1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm Instance ID." ::= { wsAlarmNotification 4 } wsAlarmNotificationDateAndTime OBJECT-TYPE SYNTAX DisplayString32 MAX-ACCESS read-only STATUS current DESCRIPTION "The local date and time when alarm was raised." ::= { wsAlarmNotification 5 } wsAlarmNotificationTableId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm table ID." ::= { wsAlarmNotification 6 } wsAlarmNotificationSeverity OBJECT-TYPE SYNTAX INTEGER { cleared(1), critical(3), major(4), minor(5), warning(6), info(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm severity." ::= { wsAlarmNotification 7 } wsAlarmNotificationInstance OBJECT-TYPE SYNTAX DisplayString32 MAX-ACCESS read-only STATUS current DESCRIPTION "The object instance the alarm is raised against." ::= { wsAlarmNotification 8 } wsAlarmNotificationDescription OBJECT-TYPE SYNTAX DisplayString32 MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm description." ::= { wsAlarmNotification 9 } wsAlarmNotificationActiveStatus OBJECT-TYPE SYNTAX INTEGER { active(1), inactive(2), intermittent(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm active status." ::= { wsAlarmNotification 10 } -- Port Type wsAlarmNotificationEntityType OBJECT-TYPE SYNTAX INTEGER { notApplicable(0), other(1), clientPort(2), linePort(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm source entity type if applicable." ::= { wsAlarmNotification 11 } -- Link state notifications -- The following notification communicates the state of a link. This includes -- detailed information about the current health of the link. wsLinkStateAlarmNotification NOTIFICATION-TYPE OBJECTS { wsLinkStateAlarmNotificationSiteId, wsLinkStateAlarmNotificationGroupId, wsLinkStateAlarmNotificationMemberId, wsLinkStateAlarmNotificationInstanceId, wsLinkStateAlarmNotificationDateAndTime, wsLinkStateAlarmNotificationSeverity, wsLinkStateAlarmNotificationInstance, wsLinkStateAlarmNotificationDescription, wsLinkStateAlarmNotificationPtpRxLos, wsLinkStateAlarmNotificationPtpRxLol, wsLinkStateAlarmNotificationPtpTxLos, wsLinkStateAlarmNotificationPtpTxLol, wsLinkStateAlarmNotificationEthFecLossSync, wsLinkStateAlarmNotificationEthEBer, wsLinkStateAlarmNotificationEthRsLf, wsLinkStateAlarmNotificationEthRsRf, wsLinkStateAlarmNotificationEthPcsLobl, wsLinkStateAlarmNotificationEthPcsLoam, wsLinkStateAlarmNotificationEthPcsLol, wsLinkStateAlarmNotificationEthRsLinkDown, wsLinkStateAlarmNotificationOtuLoc, wsLinkStateAlarmNotificationOtuFreqOor, wsLinkStateAlarmNotificationOtuLof, wsLinkStateAlarmNotificationOtuPreFecSf, wsLinkStateAlarmNotificationOtuPreFecSd, wsLinkStateAlarmNotificationOtuLom, wsLinkStateAlarmNotificationOtuBdi, wsLinkStateAlarmNotificationOtuTtiMismatch, wsLinkStateAlarmNotificationOduOci, wsLinkStateAlarmNotificationOduAis, wsLinkStateAlarmNotificationOduLck, wsLinkStateAlarmNotificationOduSf, wsLinkStateAlarmNotificationOduSd, wsLinkStateAlarmNotificationOduTtiMismatch, wsLinkStateAlarmNotificationOduBdi, wsLinkStateAlarmNotificationOduPtiMismatch, wsLinkStateAlarmNotificationOduFeClientSf, wsLinkStateAlarmNotificationOduSkewOor, wsLinkStateAlarmNotificationEntityType } STATUS current DESCRIPTION "Ciena Waveserver notification for line faults." ::= { cienaWsNotifications 12 } wsLinkStateAlarmNotificationSiteId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The line fault site ID." ::= { wsLinkStateAlarmNotification 1 } wsLinkStateAlarmNotificationGroupId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The system Group ID." ::= { wsLinkStateAlarmNotification 2 } wsLinkStateAlarmNotificationMemberId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The system Member ID." ::= { wsLinkStateAlarmNotification 3 } wsLinkStateAlarmNotificationInstanceId OBJECT-TYPE SYNTAX Unsigned32(1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The line fault instance ID." ::= { wsLinkStateAlarmNotification 4 } wsLinkStateAlarmNotificationDateAndTime OBJECT-TYPE SYNTAX DisplayString32 MAX-ACCESS read-only STATUS current DESCRIPTION "The local date and time when alarm was raised." ::= { wsLinkStateAlarmNotification 5 } wsLinkStateAlarmNotificationSeverity OBJECT-TYPE SYNTAX INTEGER { cleared(1), critical(3), major(4), minor(5), warning(6), info(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm severity." ::= { wsLinkStateAlarmNotification 7 } wsLinkStateAlarmNotificationInstance OBJECT-TYPE SYNTAX DisplayString32 MAX-ACCESS read-only STATUS current DESCRIPTION "The object instance the alarm is raised against." ::= { wsLinkStateAlarmNotification 8 } wsLinkStateAlarmNotificationDescription OBJECT-TYPE SYNTAX DisplayString32 MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm description." ::= { wsLinkStateAlarmNotification 9 } -- PTP wsLinkStateAlarmNotificationPtpDefects OBJECT-IDENTITY STATUS current DESCRIPTION "Defects related to the physical termination point." ::= { wsLinkStateAlarmNotification 10 } wsLinkStateAlarmNotificationPtpRxLos OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "PTP alarms for the link." ::= { wsLinkStateAlarmNotificationPtpDefects 1 } wsLinkStateAlarmNotificationPtpRxLol OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "PTP alarms for the link." ::= { wsLinkStateAlarmNotificationPtpDefects 2 } wsLinkStateAlarmNotificationPtpTxLos OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "PTP alarms for the link." ::= { wsLinkStateAlarmNotificationPtpDefects 3 } wsLinkStateAlarmNotificationPtpTxLol OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "PTP alarms for the link." ::= { wsLinkStateAlarmNotificationPtpDefects 4 } -- Ethernet alarms wsLinkStateAlarmNotificationEthDefects OBJECT-IDENTITY STATUS current DESCRIPTION "Ethernet defects." ::= { wsLinkStateAlarmNotification 11 } wsLinkStateAlarmNotificationEthPcsHighBer OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet PCS high bit error rate." ::= { wsLinkStateAlarmNotificationEthDefects 1 } wsLinkStateAlarmNotificationEthPcsLoam OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet PCS loss of alignment marker." ::= { wsLinkStateAlarmNotificationEthDefects 2 } wsLinkStateAlarmNotificationEthPcsLobl OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet PCS loss of block lock." ::= { wsLinkStateAlarmNotificationEthDefects 3 } wsLinkStateAlarmNotificationEthRsLinkDown OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet RS link down." ::= { wsLinkStateAlarmNotificationEthDefects 4 } wsLinkStateAlarmNotificationEthRsLf OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet RS local fault." ::= { wsLinkStateAlarmNotificationEthDefects 5 } wsLinkStateAlarmNotificationEthRsRf OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet RS remote fault." ::= { wsLinkStateAlarmNotificationEthDefects 6 } wsLinkStateAlarmNotificationEthFecLossSync OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet FEC loss of alignment marker." ::= { wsLinkStateAlarmNotificationEthDefects 7 } wsLinkStateAlarmNotificationEthPmaSool OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet PMA serdes out of lock." ::= { wsLinkStateAlarmNotificationEthDefects 8 } -- OTU Alarms wsLinkStateAlarmNotificationOtuDefects OBJECT-IDENTITY STATUS current DESCRIPTION "OTU layer defects." ::= { wsLinkStateAlarmNotification 12 } wsLinkStateAlarmNotificationOtuLoc OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "OTU loss of clock." ::= { wsLinkStateAlarmNotificationOtuDefects 1} wsLinkStateAlarmNotificationOtuFreqOor OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "OTU frequency out of range." ::= { wsLinkStateAlarmNotificationOtuDefects 2 } wsLinkStateAlarmNotificationOtuLof OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "OTU loss of frame." ::= { wsLinkStateAlarmNotificationOtuDefects 3 } wsLinkStateAlarmNotificationOtuPreFecSf OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "OTU pre-FEC signal fail." ::= { wsLinkStateAlarmNotificationOtuDefects 4 } wsLinkStateAlarmNotificationOtuPreFecSd OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "OTU pre-FEC signal degrade." ::= { wsLinkStateAlarmNotificationOtuDefects 5 } wsLinkStateAlarmNotificationOtuLom OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "OTU loss of multi-frame." ::= { wsLinkStateAlarmNotificationOtuDefects 6 } wsLinkStateAlarmNotificationOtuBdi OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "OTU backwards defect indicator." ::= { wsLinkStateAlarmNotificationOtuDefects 7 } wsLinkStateAlarmNotificationOtuTtiMismatch OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "OTU TTI mismatch." ::= { wsLinkStateAlarmNotificationOtuDefects 8 } -- ODU wsLinkStateAlarmNotificationOduDefects OBJECT-IDENTITY STATUS current DESCRIPTION "ODU layer defects." ::= { wsLinkStateAlarmNotification 13 } wsLinkStateAlarmNotificationOduOci OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "ODU open connection indication." ::= { wsLinkStateAlarmNotificationOduDefects 1 } wsLinkStateAlarmNotificationOduAis OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "ODU alarm indicating signal." ::= { wsLinkStateAlarmNotificationOduDefects 2 } wsLinkStateAlarmNotificationOduLck OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "ODU locked." ::= { wsLinkStateAlarmNotificationOduDefects 3 } wsLinkStateAlarmNotificationOduSf OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "ODU signal fail." ::= { wsLinkStateAlarmNotificationOduDefects 4 } wsLinkStateAlarmNotificationOduSd OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "ODU signal degrade." ::= { wsLinkStateAlarmNotificationOduDefects 5 } wsLinkStateAlarmNotificationOduTtiMismatch OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "ODU TTI mismatch." ::= { wsLinkStateAlarmNotificationOduDefects 6 } wsLinkStateAlarmNotificationOduBdi OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "ODU backwards defect indicator." ::= { wsLinkStateAlarmNotificationOduDefects 7 } wsLinkStateAlarmNotificationOduPtiMismatch OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "ODU payload type indicator mismatch." ::= { wsLinkStateAlarmNotificationOduDefects 8 } wsLinkStateAlarmNotificationOduFeClientSf OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "ODU far-end client signal fail." ::= { wsLinkStateAlarmNotificationOduDefects 9 } wsLinkStateAlarmNotificationOduSkewOor OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "ODU skew out of range." ::= { wsLinkStateAlarmNotificationOduDefects 10 } wsLinkStateAlarmNotificationEntityType OBJECT-TYPE SYNTAX INTEGER { notApplicable(0), other(1), clientPort(2), linePort(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm source entity type if applicable." ::= { wsLinkStateAlarmNotification 14 } END