CIENA-WS-PLATFORM-ALARM-MIB DEFINITIONS ::= BEGIN IMPORTS cienaWsPlatformConfig FROM CIENA-WS-MIB StringMaxl16, StringMaxl32, StringMaxl44 FROM CIENA-WS-PLATFORM-TYPEDEFS-MIB MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF Integer32, MODULE-IDENTITY, OBJECT-TYPE, Unsigned32 FROM SNMPv2-SMI TEXTUAL-CONVENTION, TruthValue, DisplayString FROM SNMPv2-TC; cienaWsPlatformAlarmMIB MODULE-IDENTITY LAST-UPDATED "201809200000Z" ORGANIZATION "Ciena Corporation" CONTACT-INFO "Web URL: http://www.ciena.com/ Postal: 7035 Ridge Road Hanover, Maryland 21076 U.S.A. Phone: +1 800-921-1144 Fax: +1 410-694-5750" DESCRIPTION "This module defines Alarm data for Waveserver Ai." REVISION "201809200000Z" DESCRIPTION "Changed the name of the MIB to include Platform in the name. Added intermittent to alarmReason typedef." REVISION "201808140000Z" DESCRIPTION "Added MIB definition." ::= { cienaWsPlatformConfig 4 } AlarmReason ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "None" SYNTAX INTEGER { reset(1), set(2), acknowledge(5), clear(6), delete(7), config(9), intermittent(10) } AlarmSeverity ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "None" SYNTAX INTEGER { cleared(1), critical(3), major(4), minor(5), warning(6), info(8) } activeAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF ActiveAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Active alarms" ::= { cienaWsPlatformAlarmMIB 3 } activeAlarmEntry OBJECT-TYPE SYNTAX ActiveAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for ActiveAlarmTable." INDEX { activeAlarmInstanceId } ::= { activeAlarmTable 1 } ActiveAlarmEntry ::= SEQUENCE { activeAlarmInstanceId Integer32, activeAlarmAcknowledged TruthValue, activeAlarmTableId Unsigned32, activeAlarmSeverity AlarmSeverity, activeAlarmLocalDateTime StringMaxl32, activeAlarmInstance StringMaxl32, activeAlarmDescription StringMaxl44, activeAlarmIntermittent TruthValue, activeAlarmSiteIdentifier Unsigned32, activeAlarmGroupIdentifier Unsigned32, activeAlarmMemberIdentifier Unsigned32 } activeAlarmInstanceId OBJECT-TYPE SYNTAX Integer32(1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The alarm Instance ID" ::= { activeAlarmEntry 1 } activeAlarmAcknowledged OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm has been acknowledged." ::= { activeAlarmEntry 2 } activeAlarmTableId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm table ID." ::= { activeAlarmEntry 3 } activeAlarmSeverity OBJECT-TYPE SYNTAX AlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm severity." ::= { activeAlarmEntry 4 } activeAlarmLocalDateTime OBJECT-TYPE SYNTAX StringMaxl32 MAX-ACCESS read-only STATUS current DESCRIPTION "The local date and time when alarm was raised." ::= { activeAlarmEntry 5 } activeAlarmInstance OBJECT-TYPE SYNTAX StringMaxl32 MAX-ACCESS read-only STATUS current DESCRIPTION "The object instance the alarm is raised against." ::= { activeAlarmEntry 6 } activeAlarmDescription OBJECT-TYPE SYNTAX StringMaxl44 MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm description." ::= { activeAlarmEntry 7 } activeAlarmIntermittent OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition is intermittent." ::= { activeAlarmEntry 8 } activeAlarmSiteIdentifier OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "An integer to uniquely identify the site where this Waveserver is located." ::= { activeAlarmEntry 9 } activeAlarmGroupIdentifier OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "An integer to uniquely identify a group of Waveservers within a site." ::= { activeAlarmEntry 10 } activeAlarmMemberIdentifier OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "An integer to uniquely identify a Waveserver chassis within a group of Waveservers." ::= { activeAlarmEntry 11 } historyAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF HistoryAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Alarm history" ::= { cienaWsPlatformAlarmMIB 4 } historyAlarmEntry OBJECT-TYPE SYNTAX HistoryAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for HistoryAlarmTable." INDEX { historyAlarmId } ::= { historyAlarmTable 1 } HistoryAlarmEntry ::= SEQUENCE { historyAlarmId Integer32, historyAlarmReason AlarmReason, historyAlarmInstanceId Unsigned32, historyAlarmTableId Unsigned32, historyAlarmSeverity AlarmSeverity, historyAlarmLocalDateTime StringMaxl32, historyAlarmInstance StringMaxl32, historyAlarmDescription StringMaxl44, historyAlarmSiteIdentifier Unsigned32, historyAlarmGroupIdentifier Unsigned32, historyAlarmMemberIdentifier Unsigned32 } historyAlarmId OBJECT-TYPE SYNTAX Integer32(1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The alarm history ID" ::= { historyAlarmEntry 1 } historyAlarmReason OBJECT-TYPE SYNTAX AlarmReason MAX-ACCESS read-only STATUS current DESCRIPTION "The reason for the alarm condition." ::= { historyAlarmEntry 2 } historyAlarmInstanceId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm instance ID." ::= { historyAlarmEntry 3 } historyAlarmTableId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm table ID." ::= { historyAlarmEntry 4 } historyAlarmSeverity OBJECT-TYPE SYNTAX AlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm severity." ::= { historyAlarmEntry 5 } historyAlarmLocalDateTime OBJECT-TYPE SYNTAX StringMaxl32 MAX-ACCESS read-only STATUS current DESCRIPTION "The local date and time when alarm was raised." ::= { historyAlarmEntry 6 } historyAlarmInstance OBJECT-TYPE SYNTAX StringMaxl32 MAX-ACCESS read-only STATUS current DESCRIPTION "The object instance the alarm is raised against." ::= { historyAlarmEntry 7 } historyAlarmDescription OBJECT-TYPE SYNTAX StringMaxl44 MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm description." ::= { historyAlarmEntry 8 } historyAlarmSiteIdentifier OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "An integer to uniquely identify the site where this Waveserver is located." ::= { historyAlarmEntry 9 } historyAlarmGroupIdentifier OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "An integer to uniquely identify a group of Waveservers within a site." ::= { historyAlarmEntry 10 } historyAlarmMemberIdentifier OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "An integer to uniquely identify a Waveserver chassis within a group of Waveservers." ::= { historyAlarmEntry 11 } definedAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF DefinedAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defined Alarm Table" ::= { cienaWsPlatformAlarmMIB 5 } definedAlarmEntry OBJECT-TYPE SYNTAX DefinedAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for AlarmDefinedTable." INDEX { definedAlarmId } ::= { definedAlarmTable 1 } DefinedAlarmEntry ::= SEQUENCE { definedAlarmId Integer32, definedAlarmTableId Integer32, definedAlarmEnabled TruthValue, definedAlarmActive TruthValue, definedAlarmThreshold Unsigned32, definedAlarmCap Unsigned32, definedAlarmSeverity AlarmSeverity, definedAlarmInstance StringMaxl16, definedAlarmDescription StringMaxl44 } definedAlarmId OBJECT-TYPE SYNTAX Integer32(1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The alarm table ID." ::= { definedAlarmEntry 1 } definedAlarmTableId OBJECT-TYPE SYNTAX Integer32(1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm table ID." ::= { definedAlarmEntry 2 } definedAlarmEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm is enabled." ::= { definedAlarmEntry 3 } definedAlarmActive OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm is active." ::= { definedAlarmEntry 4 } definedAlarmThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm threshold." ::= { definedAlarmEntry 5 } definedAlarmCap OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm cap." ::= { definedAlarmEntry 6 } definedAlarmSeverity OBJECT-TYPE SYNTAX AlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm severity." ::= { definedAlarmEntry 7 } definedAlarmInstance OBJECT-TYPE SYNTAX StringMaxl16 MAX-ACCESS read-only STATUS current DESCRIPTION "The object instance the alarm is raised against." ::= { definedAlarmEntry 8 } definedAlarmDescription OBJECT-TYPE SYNTAX StringMaxl44 MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm description." ::= { definedAlarmEntry 9 } alarmStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF AlarmStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Waveserver Alarm Statistics." ::= { cienaWsPlatformAlarmMIB 6 } alarmStatisticsEntry OBJECT-TYPE SYNTAX AlarmStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for AlarmStatisticsTable." INDEX { alarmStatisticsIndex } ::= { alarmStatisticsTable 1 } AlarmStatisticsEntry ::= SEQUENCE { alarmStatisticsIndex Integer32, alarmStatisticsActive TruthValue, alarmStatisticsDisabled TruthValue, alarmStatisticsCount Unsigned32, alarmStatisticsCumulative Unsigned32, alarmStatisticsType StringMaxl32 } alarmStatisticsIndex OBJECT-TYPE SYNTAX Integer32(1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The alarm statistics table index." ::= { alarmStatisticsEntry 1 } alarmStatisticsActive OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "There is alarm active for the alarm type" ::= { alarmStatisticsEntry 2 } alarmStatisticsDisabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "There is alarm disabled for the alarm type" ::= { alarmStatisticsEntry 3 } alarmStatisticsCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The count of active alarms for the alarm type" ::= { alarmStatisticsEntry 4 } alarmStatisticsCumulative OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The cumulative count of active alarms for the alarm type " ::= { alarmStatisticsEntry 5 } alarmStatisticsType OBJECT-TYPE SYNTAX StringMaxl32 MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm type." ::= { alarmStatisticsEntry 6 } -- Conformance statements cienaWsPlatformAlarmObjects OBJECT IDENTIFIER ::= { cienaWsPlatformAlarmMIB 1 } cienaWsPlatformAlarmConformance OBJECT IDENTIFIER ::= { cienaWsPlatformAlarmMIB 2 } cienaWsPlatformAlarmGroups OBJECT IDENTIFIER ::= { cienaWsPlatformAlarmConformance 1 } cienaWsPlatformAlarmGroup OBJECT-GROUP OBJECTS { activeAlarmAcknowledged, activeAlarmTableId, activeAlarmSeverity, activeAlarmLocalDateTime, activeAlarmInstance, activeAlarmDescription, activeAlarmIntermittent, activeAlarmSiteIdentifier, activeAlarmGroupIdentifier, activeAlarmMemberIdentifier, historyAlarmReason, historyAlarmInstanceId, historyAlarmTableId, historyAlarmSeverity, historyAlarmLocalDateTime, historyAlarmInstance, historyAlarmDescription, historyAlarmSiteIdentifier, historyAlarmGroupIdentifier, historyAlarmMemberIdentifier, definedAlarmTableId, definedAlarmEnabled, definedAlarmActive, definedAlarmThreshold, definedAlarmCap, definedAlarmSeverity, definedAlarmInstance, definedAlarmDescription, alarmStatisticsActive, alarmStatisticsDisabled, alarmStatisticsCount, alarmStatisticsCumulative, alarmStatisticsType } STATUS current DESCRIPTION "Conformance Group" ::= { cienaWsPlatformAlarmGroups 1 } cienaWsPlatformAlarmCompliances OBJECT IDENTIFIER ::= { cienaWsPlatformAlarmConformance 2 } cienaWsPlatformAlarmCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance" MODULE MANDATORY-GROUPS { cienaWsPlatformAlarmGroup } ::= { cienaWsPlatformAlarmCompliances 1 } END -- End module