-- ***************************************************************** -- *** Warning *** This MIB module has been deprecated. -- *** Warning *** CERENT-HC-RMON MIB replaces this MIB -- *** Warning *** from R5.00 onwards. -- ***************************************************************** -- ***************************************************************** -- CERENT-FC-MIB.mib -- Cerent Fibre Channel MIB -- -- Copyright (c) 2003 by cisco Systems, Inc. -- All rights reserved. -- ***************************************************************** CERENT-FC-MIB DEFINITIONS ::= BEGIN IMPORTS Counter32, Counter64, Integer32, MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF ifIndex FROM IF-MIB CerentPeriod FROM CERENT-TC cerentModules, cerentRequirements, cerentGeneric FROM CERENT-GLOBAL-REGISTRY ; cerentFcMIB MODULE-IDENTITY LAST-UPDATED "0302110000Z" -- 2003/Feb/11 ORGANIZATION "Cisco Systems, Inc." CONTACT-INFO "support@Cisco.com Postal: Cisco Systems 1450 N. McDowell Blvd. Petaluma, CA 94954 Tel: +1-877-323-7368" DESCRIPTION "This MIB module defines the managed objects for performance monitoring of supported Fibre Channel interfaces." REVISION "0302110000Z" -- 2003/Feb/11 DESCRIPTION "The initial revision of this MIB." ::= { cerentModules 100 } -- MIB Object Definitions cerentFcMIBObjects OBJECT IDENTIFIER ::= { cerentGeneric 60 } -- groups in this MIB module cerentFc OBJECT IDENTIFIER ::= { cerentFcMIBObjects 1 } -- cerentFc -- This group deals with FC statistics on the Fibre Channel -- interfaces cFcStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF CFcStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table reports the current values of the Fibre channel stats on the supported interfaces." ::= { cerentFc 1 } cFcStatsEntry OBJECT-TYPE SYNTAX CFcStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A collection of Fibre Channel statisctics on an interface." INDEX { ifIndex } ::= { cFcStatsTable 1 } CFcStatsEntry ::= SEQUENCE { cFcStatsInvalidOrdSets Counter32, cFcStatsInvalidOrdSetsHigh Counter32, cFcStatsEncodingDispErr Counter32, cFcStatsEncodingDispErrHigh Counter32, cFcStatsInTotalErr Counter32, cFcStatsInTotalErrHigh Counter32, cFcStatsInFramesTrunc Counter32, cFcStatsInFramesTruncHigh Counter32, cFcStatsInFramesTooLong Counter32, cFcStatsInFramesTooLongHigh Counter32, cFcStatsInFramesBadCRC Counter32, cFcStatsInFramesBadCRCHigh Counter32, cFcStatsInFrames Counter32, cFcStatsInFramesHigh Counter32, cFcStatsInElements Counter32, cFcStatsInElementsHigh Counter32, cFcStatsInDiscards Counter32, cFcStatsInDiscardsHigh Counter32, cFcStatsOutFramesBadCRC Counter32, cFcStatsOutFramesBadCRCHigh Counter32, cFcStatsOutFrames Counter32, cFcStatsOutFramesHigh Counter32, cFcStatsOutElements Counter32, cFcStatsOutElementsHigh Counter32, cFcStatsOutDiscards Counter32, cFcStatsOutDiscardsHigh Counter32, cFcStatsLinkResets Counter32, cFcStatsLinkResetsHigh Counter32, cFcStatsGfpInSBitErr Counter32, cFcStatsGfpInSBitErrHigh Counter32, cFcStatsGfpInMBitErr Counter32, cFcStatsGfpInMBitErrHigh Counter32, cFcStatsGfpInTypeInvalid Counter32, cFcStatsGfpInTypeInvalidHigh Counter32, cFcStatsGfpInSBlkCRCErr Counter32, cFcStatsGfpInSBlkCRCErrHigh Counter32 } cFcStatsInvalidOrdSets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the number of invalid ordered sets encountered on this interface. This object only shows the lower word value of the counter.The high word value is given by cFcStatsInvalidOrdSetsHigh. SNMP v2c or v3 managers can directly use cFcStatsInvalidOrdSetsHC, which is a 64 bit counter." ::= { cFcStatsEntry 10 } cFcStatsInvalidOrdSetsHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of invalid ordered sets on the particular interface. If the value of cFcStatsInvalidOrdSets is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcStatsInvalidOrdSetsHC, which is a 64 bit counter." ::= { cFcStatsEntry 20 } cFcStatsEncodingDispErr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the number of encoding disparity errors encountered on this interface. This object only shows the lower word value of the counter.The high word value is given by cFcStatsEncodingDispErrHigh. SNMP v2c or v3 managers can directly use cFcStatsEncodingDispErrHC, which is a 64 bit counter." ::= { cFcStatsEntry 30 } cFcStatsEncodingDispErrHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of encoding disparity errors on the particular interface. If the value of cFcStatsEncodingDispErr is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcStatsEncodingDispErrHC, which is a 64 bit counter." ::= { cFcStatsEntry 40 } cFcStatsInTotalErr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the total number of errors encountered on the particular interface. This object only shows the lower word value of the counter.The high word value is given by cFcStatsInTotalErrHigh. SNMP v2c or v3 managers can directly use cFcStatsInTotalErrHC, which is a 64 bit counter." ::= { cFcStatsEntry 50 } cFcStatsInTotalErrHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the total number of errors encountered on the particular interface. If the value of cFcStatsInTotalErr is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcStatsInTotalErrHC, which is a 64 bit counter." ::= { cFcStatsEntry 60 } cFcStatsInFramesTrunc OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of fibre channel truncated frames received on this interface. This object only shows the lower word value of the counter.The high word value is given by cFcStatsInFramesTruncHigh. SNMP v2c or v3 managers can directly use cFcStatsInFramesTruncHC, which is a 64 bit counter." ::= { cFcStatsEntry 70 } cFcStatsInFramesTruncHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of fibre channel truncated frames received on this interface. If the value of cFcStatsInFramesTrunc is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcStatsInFramesTruncHC, which is a 64 bit counter." ::= { cFcStatsEntry 80 } cFcStatsInFramesTooLong OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the number of fibre channel frames received on this interface with a length greater than what was agreed to. This object only shows the lower word value of the counter.The high word value is given by cFcStatsInFramesTooLongHigh. SNMP v2c or v3 managers can directly use cFcStatsInFramesTooLongHC, which is a 64 bit counter." ::= { cFcStatsEntry 90 } cFcStatsInFramesTooLongHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of fibre channel frames received on this interface with a length greater than what was agreed to. If the value of cFcStatsInFramesTooLong is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcStatsInFramesTooLongHC, which is a 64 bit counter." ::= { cFcStatsEntry 100 } cFcStatsInFramesBadCRC OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of frames received with invalid CRC, on this interface. This object only shows the lower word value of the counter.The high word value is given by cFcStatsInFramesBadCRCHigh. SNMP v2c or v3 managers can directly use cFcStatsInFramesBadCRCHC, which is a 64 bit counter." ::= { cFcStatsEntry 110 } cFcStatsInFramesBadCRCHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value of the number of frames received with invalid CRC, on this interface. If the value of cFcStatsInFramesBadCRC is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcStatsInFramesBadCRCHigh, which is a 64 bit counter." ::= { cFcStatsEntry 120 } cFcStatsInFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of fibre channel frames received on this interface. This object only shows the lower word value of the counter.The high word value is given by cFcStatsInFramesHigh. SNMP v2c or v3 managers can directly use cFcStatsInFramesHC, which is a 64 bit counter." ::= { cFcStatsEntry 130 } cFcStatsInFramesHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of fibre channel frames received on this interface. If the value of cFcStatsInFrames is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcStatsInFramesHC, which is a 64 bit counter." ::= { cFcStatsEntry 140 } cFcStatsInElements OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of received bytes on the particular interface. This object only shows the lower word value of the counter.The high word value is given by cFcStatsInElementsHigh. SNMP v2c or v3 managers can directly use cFcStatsInElementsHC, which is a 64 bit counter." ::= { cFcStatsEntry 150 } cFcStatsInElementsHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of received bytes on the particular interface. If the value of cFcStatsInElements is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcStatsInElementsHC, which is a 64 bit counter." ::= { cFcStatsEntry 160 } cFcStatsInDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of received frames on this interface that were discarded. This object only shows the lower word value of the counter.The high word value is given by cFcStatsInDiscardsHigh. SNMP v2c or v3 managers can directly use cFcStatsInDiscardsHC, which is a 64 bit counter." ::= { cFcStatsEntry 170 } cFcStatsInDiscardsHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of received frames discarded on the particular interface. If the value of cFcStatsInDiscards is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcStatsInDiscardsHC, which is a 64 bit counter." ::= { cFcStatsEntry 180 } cFcStatsOutFramesBadCRC OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the number of frames transmitted with invalid CRC, on this interface. This object only shows the lower word value of the counter.The high word value is given by cFcStatsOutFramesBadCRCHigh. SNMP v2c or v3 managers can directly use cFcStatsOutFramesBadCRCHC, which is a 64 bit counter." ::= { cFcStatsEntry 190 } cFcStatsOutFramesBadCRCHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of frames transmitted with invalid CRC, on this interface. If the value of cFcStatsOutFramesBadCRC is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcStatsOutFramesBadCRCHC, which is a 64 bit counter." ::= { cFcStatsEntry 200 } cFcStatsOutFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the number of fibre channel frames transmitted on this interface. This object only shows the lower word value of the counter.The high word value is given by cFcStatsOutFramesHigh. SNMP v2c or v3 managers can directly use cFcStatsOutFramesHC, which is a 64 bit counter." ::= { cFcStatsEntry 210 } cFcStatsOutFramesHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value of the number of fibre channel frames transmitted on this interface. If the value of cFcStatsOutFrames is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcStatsOutFramesHC, which is a 64 bit counter." ::= { cFcStatsEntry 220 } cFcStatsOutElements OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of trasmitted bytes on the particular interface. This object only shows the lower word value of the counter.The high word value is given by cFcStatsOutElementsHigh. SNMP v2c or v3 managers can directly use cFcStatsOutElementsHC, which is a 64 bit counter." ::= { cFcStatsEntry 230 } cFcStatsOutElementsHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of transmitted bytes on the particular interface. If the value of cFcStatsOutElements is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcStatsOutElementsHC, which is a 64 bit counter." ::= { cFcStatsEntry 240 } cFcStatsOutDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the number of transmitted frames on this interface that were discarded. This object only shows the lower word value of the counter.The high word value is given by cFcStatsOutDiscardsHigh. SNMP v2c or v3 managers can directly use cFcStatsOutDiscardsHC, which is a 64 bit counter." ::= { cFcStatsEntry 250 } cFcStatsOutDiscardsHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value of the number of transmitted frames on this interface that were discarded. If the value of cFcStatsOutDiscards is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcStatsOutDiscardsHC, which is a 64 bit counter." ::= { cFcStatsEntry 260 } cFcStatsLinkResets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of link resets detected on this particular interface. This object only shows the lower word value of the counter.The high word value is given by cFcStatsLinkResetsHigh. SNMP v2c or v3 managers can directly use cFcStatsLinkResetsHC, which is a 64 bit counter." ::= { cFcStatsEntry 270 } cFcStatsLinkResetsHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of link resets detected on the particular interface. If the value of cFcStatsLinkResets is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcStatsLinkResetsHC, which is a 64 bit counter." ::= { cFcStatsEntry 280 } cFcStatsGfpInSBitErr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of single bit GFP errors received on this interface. This object only shows the lower word value of the counter.The high word value is given by cFcStatsGfpInSBitErrHigh. SNMP v2c or v3 managers can directly use cFcStatsGfpInSBitErrHC, which is a 64 bit counter." ::= { cFcStatsEntry 290 } cFcStatsGfpInSBitErrHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of single bit GFP errors received on this interface. If the value of cFcStatsGfpInSBitErr is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcStatsGfpInSBitErrHC, which is a 64 bit counter." ::= { cFcStatsEntry 300 } cFcStatsGfpInMBitErr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of multi bit GFP errors received on this interface. This object only shows the lower word value of the counter.The high word value is given by cFcStatsGfpInMBitErrHigh. SNMP v2c or v3 managers can directly use cFcStatsGfpInMBitErrHC, which is a 64 bit counter." ::= { cFcStatsEntry 310 } cFcStatsGfpInMBitErrHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of multi bit GFP errors received on this interface. If the value of cFcStatsGfpInMBitErr is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcStatsGfpInMBitErrHC, which is a 64 bit counter." ::= { cFcStatsEntry 320 } cFcStatsGfpInTypeInvalid OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of GFP frames received on this interface with an invalid type. This object only shows the lower word value of the counter.The high word value is given by cFcStatsGfpInTypeInvalidHigh. SNMP v2c or v3 managers can directly use cFcStatsGfpInTypeInvalidHC, which is a 64 bit counter." ::= { cFcStatsEntry 330 } cFcStatsGfpInTypeInvalidHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value of the number of GFP frames received on this interface with an invalid type. If the value of cFcStatsGfpInTypeInvalid is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcStatsGfpInTypeInvalidHC, which is a 64 bit counter." ::= { cFcStatsEntry 340 } cFcStatsGfpInSBlkCRCErr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of GFP super block CRC errors received on this interface. This object only shows the lower word value of the counter.The high word value is given by cFcStatsGfpInSblkCRCErrHigh. SNMP v2c or v3 managers can directly use cFcStatsGfpInSblkCRCErrHC, which is a 64 bit counter." ::= { cFcStatsEntry 350 } cFcStatsGfpInSBlkCRCErrHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of GFP super block CRC errors received on the particular interface. If the value of cFcStatsGfpInSblkCRCErr is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcStatsGfpInSblkCRCErrHC, which is a 64 bit counter." ::= { cFcStatsEntry 360 } -- Fibre Channel HC table (High Capacity 64 bit counters) cFcStatsHCTable OBJECT-TYPE SYNTAX SEQUENCE OF CFcStatsHCEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table reports GFP stats on supported Fibre Channel interfaces." ::= { cerentFc 2 } cFcStatsHCEntry OBJECT-TYPE SYNTAX CFcStatsHCEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A collection of Fibre channel statisctics on an interface. All the counters in this table are 64 bits counters and are useful only to SNMP v2 and v3 managers." INDEX { ifIndex } ::= { cFcStatsHCTable 1 } CFcStatsHCEntry ::= SEQUENCE { cFcStatsInvalidOrdSetsHC Counter64, cFcStatsEncodingDispErrHC Counter64, cFcStatsInTotalErrHC Counter64, cFcStatsInFramesTruncHC Counter64, cFcStatsInFramesTooLongHC Counter64, cFcStatsInFramesBadCRCHC Counter64, cFcStatsInFramesHC Counter64, cFcStatsInElementsHC Counter64, cFcStatsInDiscardsHC Counter64, cFcStatsOutFramesBadCRCHC Counter64, cFcStatsOutFramesHC Counter64, cFcStatsOutElementsHC Counter64, cFcStatsOutDiscardsHC Counter64, cFcStatsLinkResetsHC Counter64, cFcStatsGfpInSBitErrHC Counter64, cFcStatsGfpInMBitErrHC Counter64, cFcStatsGfpInTypeInvalidHC Counter64, cFcStatsGfpInSBlkCRCErrHC Counter64 } cFcStatsInvalidOrdSetsHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of invalid ordered sets encountered on this interface. This is a High Capacity ( 64 bit ) counter." ::= { cFcStatsHCEntry 10 } cFcStatsEncodingDispErrHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of encoding disparity errors encountered on this interface. This is a High Capacity ( 64 bit ) counter." ::= { cFcStatsHCEntry 20 } cFcStatsInTotalErrHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the total number of errors encountered on this interface. This is a High Capacity ( 64 bit ) counter." ::= { cFcStatsHCEntry 30 } cFcStatsInFramesTruncHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of fibre channel truncated frames received on this interface. This is a High Capacity ( 64 bit ) counter." ::= { cFcStatsHCEntry 40 } cFcStatsInFramesTooLongHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of fibre channel frames received with a length greater than what was agreed to on this interface. This is a High Capacity ( 64 bit ) counter." ::= { cFcStatsHCEntry 50 } cFcStatsInFramesBadCRCHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of frames received with invalid CRC, on this interface. This is a High Capacity ( 64 bit ) counter." ::= { cFcStatsHCEntry 60 } cFcStatsInFramesHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of fibre channel frames received on this interface. This is a High Capacity ( 64 bit ) counter." ::= { cFcStatsHCEntry 70 } cFcStatsInElementsHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of bytes received on this interface. This is a High Capacity ( 64 bit ) counter." ::= { cFcStatsHCEntry 80 } cFcStatsInDiscardsHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames discarded on this interface. This is a High Capacity ( 64 bit ) counter." ::= { cFcStatsHCEntry 90 } cFcStatsOutFramesBadCRCHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted frames with invalid CRC, on this interface. This is a High Capacity ( 64 bit ) counter." ::= { cFcStatsHCEntry 100 } cFcStatsOutFramesHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of fibre channel frames transmitted on this interface. This is a High Capacity ( 64 bit ) counter." ::= { cFcStatsHCEntry 110 } cFcStatsOutElementsHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of bytes transmitted on this interface. This is a High Capacity ( 64 bit ) counter." ::= { cFcStatsHCEntry 120 } cFcStatsOutDiscardsHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted frames on this interface that were discarded. This is a High Capacity ( 64 bit ) counter." ::= { cFcStatsHCEntry 130 } cFcStatsLinkResetsHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of link resets detected on this interface. This is a High Capacity ( 64 bit ) counter." ::= { cFcStatsHCEntry 140 } cFcStatsGfpInSBitErrHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of single bit GFP errors received on this interface. This is a High Capacity ( 64 bit ) counter." ::= { cFcStatsHCEntry 150 } cFcStatsGfpInMBitErrHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of multi bit GFP errors received on this interface. This is a High Capacity ( 64 bit ) counter." ::= { cFcStatsHCEntry 160 } cFcStatsGfpInTypeInvalidHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of GFP frames received on this interface with an invalid type. This is a High Capacity ( 64 bit ) counter." ::= { cFcStatsHCEntry 170 } cFcStatsGfpInSBlkCRCErrHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of GFP super block CRC errors received on this interface. This is a High Capacity ( 64 bit ) counter." ::= { cFcStatsHCEntry 180 } -- cFcHistTable cFcHistTable OBJECT-TYPE SYNTAX SEQUENCE OF CFcHistEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table reports fibre channel stats on supported interfaces for previous intervals." ::= { cerentFc 3 } cFcHistEntry OBJECT-TYPE SYNTAX CFcHistEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A collection of Fibre Channel stats history on an interface." INDEX { ifIndex, cFcHistIntervalType, cFcHistIntervalNum } ::= { cFcHistTable 1 } CFcHistEntry ::= SEQUENCE { cFcHistIntervalType CerentPeriod, cFcHistIntervalNum INTEGER, cFcHistInvalidOrdSets Counter32, cFcHistInvalidOrdSetsHigh Counter32, cFcHistEncodingDispErr Counter32, cFcHistEncodingDispErrHigh Counter32, cFcHistInTotalErr Counter32, cFcHistInTotalErrHigh Counter32, cFcHistInFramesTrunc Counter32, cFcHistInFramesTruncHigh Counter32, cFcHistInFramesTooLong Counter32, cFcHistInFramesTooLongHigh Counter32, cFcHistInFramesBadCRC Counter32, cFcHistInFramesBadCRCHigh Counter32, cFcHistInFrames Counter32, cFcHistInFramesHigh Counter32, cFcHistInElements Counter32, cFcHistInElementsHigh Counter32, cFcHistInDiscards Counter32, cFcHistInDiscardsHigh Counter32, cFcHistOutFramesBadCRC Counter32, cFcHistOutFramesBadCRCHigh Counter32, cFcHistOutFrames Counter32, cFcHistOutFramesHigh Counter32, cFcHistOutElements Counter32, cFcHistOutElementsHigh Counter32, cFcHistOutDiscards Counter32, cFcHistOutDiscardsHigh Counter32, cFcHistLinkResets Counter32, cFcHistLinkResetsHigh Counter32, cFcHistGfpInSBitErr Counter32, cFcHistGfpInSBitErrHigh Counter32, cFcHistGfpInMBitErr Counter32, cFcHistGfpInMBitErrHigh Counter32, cFcHistGfpInTypeInvalid Counter32, cFcHistGfpInTypeInvalidHigh Counter32, cFcHistGfpInSBlkCRCErr Counter32, cFcHistGfpInSBlkCRCErrHigh Counter32 } cFcHistIntervalType OBJECT-TYPE SYNTAX CerentPeriod MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies the type of interval for which the data is being obtained." ::= { cFcHistEntry 10 } cFcHistIntervalNum OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object gives the number of the particular interval for which the data is being obtained." ::= { cFcHistEntry 20 } cFcHistInvalidOrdSets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of invalid ordered sets on the particular interface during this sampling interval. This object only shows the lower word value of the counter. The high word value is given by cFcHistInvalidOrdSetsHigh. SNMP v2c or v3 managers can directly use cFcHistInvalidOrdSetsHC, which is a 64 bit counter." ::= { cFcHistEntry 30 } cFcHistInvalidOrdSetsHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of invalid ordered sets on the particular interface during this sampling interval. If the value of cFcHistInvalidOrdSets is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcHistInvalidOrdSetsHC, which is a 64 bit counter." ::= { cFcHistEntry 40 } cFcHistEncodingDispErr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of encoding disparity errors on the particular interface during this sampling interval. This object only shows the lower word value of the counter.The high word value is given by cFcHistEncodingDispErrHigh. SNMP v2c or v3 managers can directly use cFcHistEncodingDispErrHC, which is a 64 bit counter." ::= { cFcHistEntry 50 } cFcHistEncodingDispErrHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of encoding disparity errors on the particular interface during this sampling interval. If the value of cFcHistEncodingDispErr is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcHistEncodingDispErrHC, which is a 64 bit counter." ::= { cFcHistEntry 60 } cFcHistInTotalErr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the total number of errors encountered on this interface during this sampling interval. This object only shows the lower word value of the counter.The high word value is given by cFcHistInTotalErrHigh. SNMP v2c or v3 managers can directly use cFcHistInTotalErrHC, which is a 64 bit counter." ::= { cFcHistEntry 70 } cFcHistInTotalErrHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value of the total number of errors encountered on this interface during this sampling interval. If the value of cFcHistInTotalErr is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcHistInTotalErrHC, which is a 64 bit counter." ::= { cFcHistEntry 80 } cFcHistInFramesTrunc OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the number of fibre channel truncated frames received on the particular interface during this sampling interval. This object only shows the lower word value of the counter.The high word value is given by cFcHistInFramesTruncHigh. SNMP v2c or v3 managers can directly use cFcHistInFramesTruncHC, which is a 64 bit counter." ::= { cFcHistEntry 90 } cFcHistInFramesTruncHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of fibre channel truncated frames received on this interface during this sampling interval. If the value of cFcHistInFramesTrunc is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcHistInFramesTruncHC, which is a 64 bit counter." ::= { cFcHistEntry 100 } cFcHistInFramesTooLong OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of fibre channel frames received on this interface during this sampling interval with a length greater than what was agreed to. This object only shows the lower word value of the counter.The high word value is given by cFcHistInFramesTooLongHigh. SNMP v2c or v3 managers can directly use cFcHistInFramesTooLongHC, which is a 64 bit counter." ::= { cFcHistEntry 110 } cFcHistInFramesTooLongHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of fibre channel frames received on this interface during this sampling interval with a length greater than what was agreed to. If the value of cFcHistInFramesTooLong is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcHistInFramesTooLongHC, which is a 64 bit counter." ::= { cFcHistEntry 120 } cFcHistInFramesBadCRC OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of frames received with invalid CRC, on this interface during this sampling interval. This object only shows the lower word value of the counter.The high word value is given by cFcHistInFramesBadCRCHigh. SNMP v2c or v3 managers can directly use cFcHistInFramesBadCRCHC, which is a 64 bit counter." ::= { cFcHistEntry 130 } cFcHistInFramesBadCRCHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of frames received with invalid CRC, on this interface during this sampling interval. If the value of cFcHistInFramesBadCRC is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcHistInFramesBadCRCHigh, which is a 64 bit counter." ::= { cFcHistEntry 140 } cFcHistInFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of fibre channel frames received on this interface during this sampling interval. This object only shows the lower word value of the counter.The high word value is given by cFcHistInFramesHigh. SNMP v2c or v3 managers can directly use cFcHistInFramesHC, which is a 64 bit counter." ::= { cFcHistEntry 150 } cFcHistInFramesHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of fibre channel frames received on this interface during this sampling interval. If the value of cFcHistInFrames is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcHistInFramesHC, which is a 64 bit counter." ::= { cFcHistEntry 160 } cFcHistInElements OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of received bytes on the particular interface during this sampling interval. This object only shows the lower word value of the counter.The high word value is given by cFcHistInElementsHigh. SNMP v2c or v3 managers can directly use cFcHistInElementsHC, which is a 64 bit counter." ::= { cFcHistEntry 170 } cFcHistInElementsHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of received bytes on the particular interface during this sampling interval. If the value of cFcHistInElements is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcHistInElementsHC, which is a 64 bit counter." ::= { cFcHistEntry 180 } cFcHistInDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the the number of received frames discarded on this interface during this sampling interval. This object only shows the lower word value of the counter.The high word value is given by cFcHistInDiscardsHigh. SNMP v2c or v3 managers can directly use cFcHistInDiscardsHC, which is a 64 bit counter." ::= { cFcHistEntry 190 } cFcHistInDiscardsHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value of the number of received frames discarded on this interface during this sampling interval. If the value of cFcHistInDiscards is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcHistInDiscardsHC, which is a 64 bit counter." ::= { cFcHistEntry 200 } cFcHistOutFramesBadCRC OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the the number of frames transmitted with invalid CRC, on this interface, during this sampling interval. This object only shows the lower word value of the counter.The high word value is given by cFcHistOutFramesBadCRCHigh. SNMP v2c or v3 managers can directly use cFcHistOutFramesBadCRCHC, which is a 64 bit counter." ::= { cFcHistEntry 210 } cFcHistOutFramesBadCRCHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of frames transmitted with invalid CRC, on this interface, during this sampling interval. If the value of cFcHistOutFramesBadCRC is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcHistOutFramesBadCRCHC, which is a 64 bit counter." ::= { cFcHistEntry 220 } cFcHistOutFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of frames transmitted on the particular interface during this sampling interval. This object only shows the lower word value of the counter.The high word value is given by cFcHistOutFramesHigh. SNMP v2c or v3 managers can directly use cFcHistOutFramesHC, which is a 64 bit counter." ::= { cFcHistEntry 230 } cFcHistOutFramesHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of frames transmitted on the particular interface during this sampling interval. If the value of cFcHistOutFrames is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcHistOutFramesHC, which is a 64 bit counter." ::= { cFcHistEntry 240 } cFcHistOutElements OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of trasmitted bytes on the particular interface during this sampling interval. This object only shows the lower word value of the counter.The high word value is given by cFcHistOutElementsHigh. SNMP v2c or v3 managers can directly use cFcHistOutElementsHC, which is a 64 bit counter." ::= { cFcHistEntry 250 } cFcHistOutElementsHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value of the number of transmitted bytes on the particular interface during this sampling interval. If the value of cFcHistOutElements is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcHistOutElementsHC, which is a 64 bit counter." ::= { cFcHistEntry 260 } cFcHistOutDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the number of transmitted frames discarded on this interface during this sampling interval. This object only shows the lower word value of the counter.The high word value is given by cFcHistOutDiscardsHigh. SNMP v2c or v3 managers can directly use cFcHistOutDiscardsHC, which is a 64 bit counter." ::= { cFcHistEntry 270 } cFcHistOutDiscardsHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of transmitted frames discarded on this interface during this sampling interval. If the value of cFcHistOutDiscards is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcHistOutDiscardsHC, which is a 64 bit counter." ::= { cFcHistEntry 280 } cFcHistLinkResets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of link resets detected on the particular interface during this sampling interval. This object only shows the lower word value of the counter.The high word value is given by cFcHistLinkResetsHigh. SNMP v2c or v3 managers can directly use cFcHistLinkResetsHC, which is a 64 bit counter." ::= { cFcHistEntry 290 } cFcHistLinkResetsHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of link resets detected on the particular interface during this interval. If the value of cFcHistLinkResets is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcHistLinkResetsHC, which is a 64 bit counter." ::= { cFcHistEntry 300 } cFcHistGfpInSBitErr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the number of single bit GFP errors received on this interface during this sampling interval. This object only shows the lower word value of the counter.The high word value is given by cFcHistGfpInSBitErrHigh. SNMP v2c or v3 managers can directly use cFcHistGfpInSBitErrHC, which is a 64 bit counter." ::= { cFcHistEntry 310 } cFcHistGfpInSBitErrHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value of the number of single bit GFP errors received on this interface during this sampling interval. If the value of cFcHistGfpInSBitErr is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcHistGfpInSBitErrHC, which is a 64 bit counter." ::= { cFcHistEntry 320 } cFcHistGfpInMBitErr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the number of multi bit GFP errors received on this interface during this sampling interval. This object only shows the lower word value of the counter.The high word value is given by cFcHistGfpInMBitErrHigh. SNMP v2c or v3 managers can directly use cFcHistGfpInMBitErrHC, which is a 64 bit counter." ::= { cFcHistEntry 330 } cFcHistGfpInMBitErrHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of multi bit GFP errors received on this interface during this sampling interval. If the value of cFcHistGfpInMBitErr is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcHistGfpInMBitErrHC, which is a 64 bit counter." ::= { cFcHistEntry 340 } cFcHistGfpInTypeInvalid OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of received GFP frames with an invalid type on this interface during this sampling interval. This object only shows the lower word value of the counter.The high word value is given by cFcHistGfpInTypeInvalidHigh. SNMP v2c or v3 managers can directly use cFcHistGfpInTypeInvalidHC, which is a 64 bit counter." ::= { cFcHistEntry 350 } cFcHistGfpInTypeInvalidHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value of the number of received GFP frames with an invalid type on this interface, during this sampling interval. If the value of cFcHistGfpInTypeInvalid is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcHistGfpInTypeInvalidHC, which is a 64 bit counter." ::= { cFcHistEntry 360 } cFcHistGfpInSBlkCRCErr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the value of the number of super block CRC GFP errors received on this interface during this sampling interval. This object only shows the lower word value of the counter.The high word value is given by cFcHistGfpInSblkCRCErrHigh. SNMP v2c or v3 managers can directly use cFcHistGfpInSBlkCRCErrHC, which is a 64 bit counter." ::= { cFcHistEntry 370 } cFcHistGfpInSBlkCRCErrHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object gives the higher word value the number of super block CRC GFP errors received on this interface during this sampling interval. If the value of cFcHistGfpInSblkCRCErr is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can directly use cFcHistGfpInSBlkCRCErrHC, which is a 64 bit counter." ::= { cFcHistEntry 380 } -- Fibre Channel HC table (High Capacity 64 bit counters) cFcHistHCTable OBJECT-TYPE SYNTAX SEQUENCE OF CFcHistHCEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table reports history of fibre channel stats on supported Fibre Channel interfaces." ::= { cerentFc 4 } cFcHistHCEntry OBJECT-TYPE SYNTAX CFcHistHCEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A collection of history of Fibre channel statisctics on an interface. All the counters in this table are 64 bits counters and are useful only to SNMP v2 and v3 managers." INDEX { ifIndex, cFcHistIntervalType,cFcHistIntervalNum} ::= { cFcHistHCTable 1 } CFcHistHCEntry ::= SEQUENCE { cFcHistInvalidOrdSetsHC Counter64, cFcHistEncodingDispErrHC Counter64, cFcHistInTotalErrHC Counter64, cFcHistInFramesTruncHC Counter64, cFcHistInFramesTooLongHC Counter64, cFcHistInFramesBadCRCHC Counter64, cFcHistInFramesHC Counter64, cFcHistInElementsHC Counter64, cFcHistInDiscardsHC Counter64, cFcHistOutFramesBadCRCHC Counter64, cFcHistOutFramesHC Counter64, cFcHistOutElementsHC Counter64, cFcHistOutDiscardsHC Counter64, cFcHistLinkResetsHC Counter64, cFcHistGfpInSBitErrHC Counter64, cFcHistGfpInMBitErrHC Counter64, cFcHistGfpInTypeInvalidHC Counter64, cFcHistGfpInSBlkCRCErrHC Counter64 } cFcHistInvalidOrdSetsHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of invalid ordered sets encountered on this interface during this sampling interval. This is a High Capacity ( 64 bit ) counter." ::= { cFcHistHCEntry 10 } cFcHistEncodingDispErrHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of encoding disparity errors encountered on this interface during this sampling interval. This is a High Capacity ( 64 bit ) counter." ::= { cFcHistHCEntry 20 } cFcHistInTotalErrHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the total number of errors encountered on this interface during this sampling interval. This is a High Capacity ( 64 bit ) counter." ::= { cFcHistHCEntry 30 } cFcHistInFramesTruncHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of fibre channel truncated frames received on this interface during this sampling interval. This is a High Capacity ( 64 bit ) counter." ::= { cFcHistHCEntry 40 } cFcHistInFramesTooLongHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of fibre channel frames received on this interface during this sampling interval, with a length greater than what was agreed to. This is a High Capacity ( 64 bit ) counter." ::= { cFcHistHCEntry 50 } cFcHistInFramesBadCRCHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of frames received with an invalid CRC, on this interface during this sampling interval. This is a High Capacity ( 64 bit ) counter." ::= { cFcHistHCEntry 60 } cFcHistInFramesHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of frames received on this interface, during this sampling interval. This is a High Capacity ( 64 bit ) counter." ::= { cFcHistHCEntry 70 } cFcHistInElementsHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of bytes received on this interface during this sampling interval. This is a High Capacity ( 64 bit ) counter." ::= { cFcHistHCEntry 80 } cFcHistInDiscardsHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames discarded on this interface during this sampling interval. This is a High Capacity ( 64 bit ) counter." ::= { cFcHistHCEntry 90 } cFcHistOutFramesBadCRCHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of frames transmitted with an invalid CRC, on this interface during this sampling interval. This is a High Capacity ( 64 bit ) counter." ::= { cFcHistHCEntry 100 } cFcHistOutFramesHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of fibre channel frames transmitted on this interface during this sampling interval. This is a High Capacity ( 64 bit ) counter." ::= { cFcHistHCEntry 110 } cFcHistOutElementsHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of bytes received on this interface during this sampling interval. This is a High Capacity ( 64 bit ) counter." ::= { cFcHistHCEntry 120 } cFcHistOutDiscardsHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of transmitted frames discarded on this interface during this sampling interval. This is a High Capacity ( 64 bit ) counter." ::= { cFcHistHCEntry 130 } cFcHistLinkResetsHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of link resets detected on this interface during this sampling interval. This is a High Capacity ( 64 bit ) counter." ::= { cFcHistHCEntry 140 } cFcHistGfpInSBitErrHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of single bit GFP errors received on this interface during this sampling interval. This is a High Capacity ( 64 bit ) counter." ::= { cFcHistHCEntry 150 } cFcHistGfpInMBitErrHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of multi bit GFP errors received on this interface during this sampling interval. This is a High Capacity ( 64 bit ) counter." ::= { cFcHistHCEntry 160 } cFcHistGfpInTypeInvalidHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of GFP frames with invalid type received on this interface, during this sampling interval. This is a High Capacity ( 64 bit ) counter." ::= { cFcHistHCEntry 170 } cFcHistGfpInSBlkCRCErrHC OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of GFP super block CRC errors received on this interface during this sampling interval. This is a High Capacity ( 64 bit ) counter." ::= { cFcHistHCEntry 180 } -- The cFcAlarm Table cFcAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF CFcAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of cFcAlarm entries." ::= { cerentFc 5 } cFcAlarmEntry OBJECT-TYPE SYNTAX CFcAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of parameters that set up a periodic checking for cFcAlarm conditions." INDEX { cFcAlarmIndex } ::= { cFcAlarmTable 1 } CFcAlarmEntry ::= SEQUENCE { cFcAlarmIndex INTEGER, cFcAlarmInterval INTEGER, cFcAlarmVariable OBJECT IDENTIFIER, cFcAlarmSampleType INTEGER, cFcAlarmValue Counter32, cFcAlarmValueHigh Counter32, cFcAlarmStartupAlarm INTEGER, cFcAlarmRisingThreshold Integer32, cFcAlarmRisingThresholdHigh Integer32, cFcAlarmFallingThreshold Integer32, cFcAlarmFallingThresholdHigh Integer32, cFcAlarmStatus INTEGER } cFcAlarmIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An index that uniquely identifies an entry in the cFcAlarm table. Each such entry defines a diagnostic sample at a particular interval for an object on the device." ::= { cFcAlarmEntry 10 } cFcAlarmInterval OBJECT-TYPE SYNTAX INTEGER(1..8000) MAX-ACCESS read-write STATUS current DESCRIPTION "The interval in seconds over which the data is sampled and compared with the rising and falling thresholds. When setting this variable, care should be taken in the case of deltaValue sampling - the interval should be set short enough that the sampled variable is very unlikely to increase or decrease by more than 2^31 - 1 during a single sampling interval." ::= { cFcAlarmEntry 20 } cFcAlarmVariable OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-write STATUS current DESCRIPTION "The object identifier of the particular variable to be sampled." ::= { cFcAlarmEntry 30 } cFcAlarmSampleType OBJECT-TYPE SYNTAX INTEGER { absoluteValue(1), deltaValue(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The method of sampling the selected variable and calculating the value to be compared against the thresholds. If the value of this object is absoluteValue(1), the value of the selected variable will be compared directly with the thresholds at the end of the sampling interval. If the value of this object is deltaValue(2), the value of the selected variable at the last sample will be subtracted from the current value, and the difference compared with the thresholds." ::= { cFcAlarmEntry 40 } cFcAlarmValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the statistic during the last sampling period. For example, if the sample type is deltaValue, this value will be the difference between the samples at the beginning and end of the period. If the sample type is absoluteValue, this value will be the sampled value at the end of the period. This is the value that is compared with the rising and falling thresholds. This object only shows the lower word value. The high word value is given by cFcAlarmValueHigh. The value during the current sampling period is not made available until the period is completed and will remain available until the next period completes." ::= { cFcAlarmEntry 50 } cFcAlarmValueHigh OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The higher word value of the statistic during the last sampling period. If the value of cFcAlarmValue is greater than 4,294,967,295, the higher word value will be stored in this object." ::= { cFcAlarmEntry 60 } cFcAlarmStartupAlarm OBJECT-TYPE SYNTAX INTEGER { risingcFcAlarm(1), fallingcFcAlarm(2), risingOrFallingcFcAlarm(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The cFcAlarm that may be sent when this entry is set to valid. If the first sample after this entry becomes valid is greater than or equal to the risingThreshold and cFcAlarmStartupAlarm is equal to risingcFcAlarm(1) or risingOrFallingAlarm(3), then a single rising cFcAlarm will be generated. If the sample after this entry becomes valid is less than or equal to the fallingThreshold and cFcAlarmStartupAlarm is equal to fallingAlarm(2) or risingOrFallingcFcAlarm(3), then a single falling alarm will be generated." ::= { cFcAlarmEntry 70 } cFcAlarmRisingThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "A threshold for the sampled statistic. When the current sampled value is greater than or equal to this threshold, and the value at the last sampling interval was less than this threshold, a single event will be generated. A single event will also be generated if the first sample after this entry becomes valid is greater than or equal to this threshold and the associated cFcAlarmStartupAlarm is equal to risingcFcAlarm(1) or risingOrFallingAlarm(3). After a rising event is generated, another such event will not be generated until the sampled value falls below this threshold and reaches the cFcAlarmFallingThreshold. This object can only be used to set the lower word value of the threshold. If the threshold to be set is greater than 4,294,967,295 then cFcAlarmRisingThresholdHigh should be used to set the upper word value of the threshold." ::= { cFcAlarmEntry 80 } cFcAlarmRisingThresholdHigh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The upper word value of the rising threshold for the sampled statistic. If the value of threshold to be set in cFcAlarmRisingThreshold is greater than 4,294,967,295, then this object should be used to set the upper word value of the threshold." ::= { cFcAlarmEntry 90 } cFcAlarmFallingThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "A threshold for the sampled statistic. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval was greater than this threshold, a single event will be generated. A single event will also be generated if the first sample after this entry becomes valid is less than or equal to this threshold and the associated cFcAlarmStartupAlarm is equal to fallingcFcAlarm(2) or risingOrFallingAlarm(3). After a falling event is generated, another such event will not be generated until the sampled value rises above this threshold and reaches the cFcAlarmRisingThreshold. This object can only be used to set the lower word value of the threshold. If the threshold to be set is greater than 4,294,967,295, then cFcAlarmFallingThresholdHigh should be used to set the upper word value of the threshold." ::= { cFcAlarmEntry 100 } cFcAlarmFallingThresholdHigh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The upper word value of the falling threshold for the sampled statistic. If the value of threshold to be set in cFcAlarmFallingThreshold is greater than 4,294,967,295, then this object should be used to set the upper word value of the threshold." ::= { cFcAlarmEntry 110 } cFcAlarmStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this cFcAlarm entry." ::= { cFcAlarmEntry 120 } -- MIB Conformance Statements cerentFcMIBConformance OBJECT IDENTIFIER ::= { cerentRequirements 40 } cerentFcMIBCompliances OBJECT IDENTIFIER ::= { cerentFcMIBConformance 1 } cerentFcMIBGroups OBJECT IDENTIFIER ::= { cerentFcMIBConformance 2 } cerentFcMIBCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for platforms that monitor the Fibre channel interfaces with respect to error counters, for the physical layer." MODULE -- this module MANDATORY-GROUPS { cerentFcStatsGroup } ::= { cerentFcMIBCompliances 1 } -- -- units of conformance -- cerentFcStatsGroup OBJECT-GROUP OBJECTS { cFcStatsInvalidOrdSets, cFcStatsInvalidOrdSetsHigh, cFcStatsEncodingDispErr, cFcStatsEncodingDispErrHigh, cFcStatsInTotalErr, cFcStatsInTotalErrHigh, cFcStatsInFramesTrunc, cFcStatsInFramesTruncHigh, cFcStatsInFramesTooLong, cFcStatsInFramesTooLongHigh, cFcStatsInFramesBadCRC, cFcStatsInFramesBadCRCHigh, cFcStatsInFrames, cFcStatsInFramesHigh, cFcStatsInElements, cFcStatsInElementsHigh, cFcStatsInDiscards, cFcStatsInDiscardsHigh, cFcStatsOutFramesBadCRC, cFcStatsOutFramesBadCRCHigh, cFcStatsOutFrames, cFcStatsOutFramesHigh, cFcStatsOutElements, cFcStatsOutElementsHigh, cFcStatsOutDiscards, cFcStatsOutDiscardsHigh, cFcStatsLinkResets, cFcStatsLinkResetsHigh, cFcStatsGfpInSBitErr, cFcStatsGfpInSBitErrHigh, cFcStatsGfpInMBitErr, cFcStatsGfpInMBitErrHigh, cFcStatsGfpInTypeInvalid, cFcStatsGfpInTypeInvalidHigh, cFcStatsGfpInSBlkCRCErr, cFcStatsGfpInSBlkCRCErrHigh } STATUS current DESCRIPTION "The collection of objects to give stats related to the performance of an fibre channel interface." ::= { cerentFcMIBGroups 1 } cerentFcHistGroup OBJECT-GROUP OBJECTS { cFcHistInvalidOrdSets, cFcHistInvalidOrdSetsHigh, cFcHistEncodingDispErr, cFcHistEncodingDispErrHigh, cFcHistInTotalErr, cFcHistInTotalErrHigh, cFcHistInFramesTrunc, cFcHistInFramesTruncHigh, cFcHistInFramesTooLong, cFcHistInFramesTooLongHigh, cFcHistInFramesBadCRC, cFcHistInFramesBadCRCHigh, cFcHistInFrames, cFcHistInFramesHigh, cFcHistInElements, cFcHistInElementsHigh, cFcHistInDiscards, cFcHistInDiscardsHigh, cFcHistOutFramesBadCRC, cFcHistOutFramesBadCRCHigh, cFcHistOutFrames, cFcHistOutFramesHigh, cFcHistOutElements, cFcHistOutElementsHigh, cFcHistOutDiscards, cFcHistOutDiscardsHigh, cFcHistLinkResets, cFcHistLinkResetsHigh, cFcHistGfpInSBitErr, cFcHistGfpInSBitErrHigh, cFcHistGfpInMBitErr, cFcHistGfpInMBitErrHigh, cFcHistGfpInTypeInvalid, cFcHistGfpInTypeInvalidHigh, cFcHistGfpInSBlkCRCErr, cFcHistGfpInSBlkCRCErrHigh } STATUS current DESCRIPTION "The collection of objects to give previous stats related to the performance of an fibre channel interface." ::= { cerentFcMIBGroups 2 } cerentFcStatsHCGroup OBJECT-GROUP OBJECTS { cFcStatsInvalidOrdSetsHC, cFcStatsEncodingDispErrHC, cFcStatsInTotalErrHC, cFcStatsInFramesTruncHC, cFcStatsInFramesTooLongHC, cFcStatsInFramesBadCRCHC, cFcStatsInFramesHC, cFcStatsInElementsHC, cFcStatsInDiscardsHC, cFcStatsOutFramesBadCRCHC, cFcStatsOutFramesHC, cFcStatsOutElementsHC, cFcStatsOutDiscardsHC, cFcStatsLinkResetsHC, cFcStatsGfpInSBitErrHC, cFcStatsGfpInMBitErrHC, cFcStatsGfpInTypeInvalidHC, cFcStatsGfpInSBlkCRCErrHC } STATUS current DESCRIPTION "The collection of 64 bit objects to give stats related to the performance of an fibre channel interface." ::= { cerentFcMIBGroups 3 } cerentFcHistHCGroup OBJECT-GROUP OBJECTS { cFcHistInvalidOrdSetsHC, cFcHistEncodingDispErrHC, cFcHistInTotalErrHC, cFcHistInFramesTruncHC, cFcHistInFramesTooLongHC, cFcHistInFramesBadCRCHC, cFcHistInFramesHC, cFcHistInElementsHC, cFcHistInDiscardsHC, cFcHistOutFramesBadCRCHC, cFcHistOutFramesHC, cFcHistOutElementsHC, cFcHistOutDiscardsHC, cFcHistLinkResetsHC, cFcHistGfpInSBitErrHC, cFcHistGfpInMBitErrHC, cFcHistGfpInTypeInvalidHC, cFcHistGfpInSBlkCRCErrHC } STATUS current DESCRIPTION "The collection of 64 bit objects to give previous stats related to the performance of an fibre channel interface." ::= { cerentFcMIBGroups 4 } cerentFcAlarmGroup OBJECT-GROUP OBJECTS { cFcAlarmInterval, cFcAlarmVariable, cFcAlarmSampleType, cFcAlarmValue, cFcAlarmValueHigh, cFcAlarmStartupAlarm, cFcAlarmRisingThreshold, cFcAlarmRisingThresholdHigh, cFcAlarmFallingThreshold, cFcAlarmFallingThresholdHigh, cFcAlarmStatus } STATUS current DESCRIPTION "The collection of alarm thresholds configured on fibre channel interfaces." ::= { cerentFcMIBGroups 5 } END