CISCOSB-rndApplications DEFINITIONS ::= BEGIN -- Title: CISCOSB Application Private Extension -- Version: 7.37.00.00 -- Date: 17 May 2004 IMPORTS switch001 FROM CISCOSB-MIB InterfaceIndexOrZero, InterfaceIndex, ifIndex FROM IF-MIB TEXTUAL-CONVENTION, DisplayString, RowStatus, TruthValue FROM SNMPv2-TC Unsigned32, Counter32, IpAddress, MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI InetAddressType, InetAddress FROM INET-ADDRESS-MIB; rndApplications MODULE-IDENTITY LAST-UPDATED "200406010000Z" ORGANIZATION "Cisco Systems, Inc." CONTACT-INFO "Postal: 170 West Tasman Drive San Jose , CA 95134-1706 USA Website: Cisco Small Business Support Community " DESCRIPTION "The private MIB module definition for switch001 applications MIB." REVISION "200406010000Z" DESCRIPTION "Initial version of this MIB." ::= { switch001 35 } -- Obsolete -- rsServerDispatcher OBJECT IDENTIFIER ::= { rndApplications 1} -- rndMidLevelManagement group contains variables which direct the mid-level -- management stations how to monitor and manage their domains. rndMidLevelManagement OBJECT IDENTIFIER ::= { rndApplications 2} -- NEW Group rndAlarmOptions OBJECT IDENTIFIER ::= { rndMidLevelManagement 2} rndAlarmEnabling OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether alarms should be issued to the high-level NMS " ::= { rndAlarmOptions 1 } rndAlarmInterval OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the minimal period of time which must pass after issuing an alarm before issuing the same alarm again." ::= { rndAlarmOptions 2 } rndMonitoredElementsTable OBJECT-TYPE SYNTAX SEQUENCE OF RndMonitoredElementEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of monitored elements of the network" ::= {rndMidLevelManagement 3} rndMonitoredElementEntry OBJECT-TYPE SYNTAX RndMonitoredElementEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The row definition for this table." INDEX { rndMonitoredElementAddress } ::= {rndMonitoredElementsTable 1} RndMonitoredElementEntry ::= SEQUENCE { rndMonitoredElementAddress IpAddress, rndMonitoredElementCommunity DisplayString(SIZE(1..20)), rndMonitoredElementLabel DisplayString(SIZE(1..20)), rndDefaultPollingInterval INTEGER, rndDefaultLogFile DisplayString, rndMonitoredElementStatus RowStatus } rndMonitoredElementAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the monitored element" ::= {rndMonitoredElementEntry 1 } rndMonitoredElementCommunity OBJECT-TYPE SYNTAX DisplayString(SIZE(1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "The community of the monitored element" ::= {rndMonitoredElementEntry 2 } rndMonitoredElementLabel OBJECT-TYPE SYNTAX DisplayString(SIZE(1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "The label assigned by the network manager to the monitored element" ::= {rndMonitoredElementEntry 3} rndDefaultPollingInterval OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The default period of time between two consecutive pollings of the monitored element for the value of an object instance. If no other polling interval is specifically assigned to the monitored object instance, this one will be used" ::= {rndMonitoredElementEntry 4} rndDefaultLogFile OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The default file path of the log-file which will contain the polling results for the monitored element. If no other file path is specifically assigned to the monitored object instance, this log-file will be used." ::= {rndMonitoredElementEntry 5} rndMonitoredElementStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "It is used to manage the monitored elements table and indicates the current monitoring status of an element." ::= {rndMonitoredElementEntry 6} rndMonitoringTable OBJECT-TYPE SYNTAX SEQUENCE OF RndMonitoringEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of monitored object instances. Each monitored object instance belongs to a monitored element previously entered in the rndMonitoredElementsTable. " ::= {rndMidLevelManagement 4} rndMonitoringEntry OBJECT-TYPE SYNTAX RndMonitoringEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The row definition for this table." INDEX { rndMonitoredElement, IMPLIED rndMonitoredObjectInstanceLabel } ::= {rndMonitoringTable 1} RndMonitoringEntry ::= SEQUENCE { rndMonitoredElement DisplayString(SIZE(1..20)), rndMonitoredObjectInstanceLabel DisplayString, rndMonitoredObjectName DisplayString, rndMonitoredObjectIdentifier OBJECT IDENTIFIER, rndMonitoredObjectInstance OBJECT IDENTIFIER, rndMonitoredObjectSyntax INTEGER, rndMonitoringInterval INTEGER, rndAlarmMaxTreshold INTEGER, rndAlarmMinTreshold INTEGER, rndMonitoringLogfile DisplayString, rndMonitoringEntryStatus RowStatus, rndMonitoredIntegerInstance INTEGER } rndMonitoredElement OBJECT-TYPE SYNTAX DisplayString(SIZE(1..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "A label assigned by the network manager to a monitored element to which this monitored object instance belongs. This label must have been previously entered in an instance of rndMonitoredElementLabel" ::= {rndMonitoringEntry 1} rndMonitoredObjectInstanceLabel OBJECT-TYPE SYNTAX DisplayString(SIZE(1..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "The label assigned by the network manager to the monitored object instance" ::= {rndMonitoringEntry 2} rndMonitoredObjectName OBJECT-TYPE SYNTAX DisplayString(SIZE(0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "The symbolic object type name of the object to which the monitored object instance belongs (as it appears the MIB module definition). In case of ambiguity the : format should be used. An instance of rndMonitoredObjectName need not be assigned any value, if the corresponding instance of rndMonitoredObjectIdentifier is assigned a value, since any one of these, together with the object instance identifier, suffices to unambigously identify the monitored object instance." ::= {rndMonitoringEntry 3} rndMonitoredObjectIdentifier OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-write STATUS current DESCRIPTION "The object identifier of the object to which the monitored object instance belongs. An instance of rndMonitoredObjectIdentifier need not be assigned any value, if the corresponding instance of rndMonitoredObjectName is assigned a value, since any one of these, together with the object instance identifier, suffices to unambigously identify the monitored object instance." ::= {rndMonitoringEntry 4} rndMonitoredObjectInstance OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-write STATUS current DESCRIPTION "The instance identifier (key) of the monitored object instance." ::= {rndMonitoringEntry 5} rndMonitoredObjectSyntax OBJECT-TYPE SYNTAX INTEGER { integer(1), octet-string(2), ip-address(3), object-identifier(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The syntax of the monitored object instance (i.e., the syntax of the object type of the object to which the monitored instance belongs). Need not be assigned any value if the corresponding instance of rndMonitoredObjectName has been assigned a value" ::= {rndMonitoringEntry 6} rndMonitoringInterval OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The period of time between two consecutive retrievals of the monitored object instance's value." ::= {rndMonitoringEntry 7} rndAlarmMaxTreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the monitored object instance, the exceeding of which will cause the generation of an alarm to the high-level management station." ::= {rndMonitoringEntry 8} rndAlarmMinTreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "If the value of the monitored object instance falls below the value assigned to rndAlarmMinTreshold, an alarm to the high-level management station will be issued." ::= {rndMonitoringEntry 9} rndMonitoringLogfile OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The entire path of the file in which the results of the monitoring of this object instance should be recorded." ::= {rndMonitoringEntry 10} rndMonitoringEntryStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "It is used to manage the monitored object instances table and indicates the current monitoring status of an object instance." ::= {rndMonitoringEntry 11} rndMonitoredIntegerInstance OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= {rndMonitoringEntry 12} rndMibFilesTable OBJECT-TYPE SYNTAX SEQUENCE OF RndMibFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of monitored object instances. Each monitored object instance belongs to a monitored element previously entered in the rndMonitoredElementsTable. " ::= {rndMidLevelManagement 5} rndMibFileEntry OBJECT-TYPE SYNTAX RndMibFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The row definition for this table." INDEX { rndMibFileIndex } ::= {rndMibFilesTable 1} RndMibFileEntry ::= SEQUENCE { rndMibFileIndex INTEGER, rndMibFilePath DisplayString, rndMibFileRefresh INTEGER, rndMibFileEntryStatus RowStatus } rndMibFileIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the MIB file in the list MIB files supported by the Mid-Level management station. The order of the MIB files in this list must reflect the the IMPORT relation between the MIBS contained in the MIB files, i.e., if MIB A IMPORTS FROM MIB B, the file containing MIB A must have a lesser index in this table than the file containing MIB B." ::= {rndMibFileEntry 1} rndMibFilePath OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The path of the MIB file in the MIB file server." ::= {rndMibFileEntry 2} rndMibFileRefresh OBJECT-TYPE SYNTAX INTEGER { no(1), yes(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if the file should be fetched after setting this entry from the MIB file server." ::= {rndMibFileEntry 3} rndMibFileEntryStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "It is used to manage the MIB files table." ::= {rndMibFileEntry 4} rndHardwareConfiguration OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether the current SET SNMP PDU contains hardware configuration (i.e., normally read-only variables). SET of such variables in the Mid-level management station will be allowed only if this variable is included in the SNMP PDU and its value is true. Its value as returned in a GET SNMP PDU will always be false." ::= {rndMidLevelManagement 6} rndEraseSimulatedConfiguration OBJECT-TYPE SYNTAX INTEGER { eraseSimulatedConfiguration(1), simulatedConfigurationPresent(2), simulatedConfigurationErased(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "eraseSimulatedConfiguration instructs the MLNMS to erase all the simulated configuration from its configuration data-base (CDB). This the only accepted value for SNMP SET statements and will never be returned in SNMP GET statements. simulatedConfigurationPresent indicates that the MLNMS currently has a simulated configuration. simulatedConfigurationErased indicates that the MLNMS currently has no simulated configuration." ::= {rndMidLevelManagement 7} rndDeleteValuesTable OBJECT-TYPE SYNTAX SEQUENCE OF RndDeleteValuesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table indicates which MIB variables are row status fields which control the status of the entry to which they belong. This table also indicates which (integer!) value of these MIB variables will cause, if present in a SNMP SET PDU, the deletion of the conceptual row instance to which the SET MIB variable instance belongs." ::= {rndMidLevelManagement 8} rndDeleteValuesEntry OBJECT-TYPE SYNTAX RndDeleteValuesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The row definition for the rndDeleteValuesTable table." INDEX { IMPLIED rndRowStatusVariableName } ::= {rndDeleteValuesTable 1} RndDeleteValuesEntry ::= SEQUENCE { rndRowStatusVariableName DisplayString, rndRowStatusObjectId OBJECT IDENTIFIER, rndRowDeleteValue INTEGER, rndDeleteValueEntryStatus RowStatus } rndRowStatusVariableName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..80)) -- MAX-ACCESS read-only MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the row status field. This name may not necessarily be any name which is present in the MIBs loaded into the MLNMS station." ::= {rndDeleteValuesEntry 1} rndRowStatusObjectId OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-write STATUS current DESCRIPTION "The object id of the row status field. If the rndRowStatusVariableName is a name present in the MIBs loaded into the MLNMS, this MIB variable is not required, but if given, it must match the object id known to the MLNMS. The variable identified by rndRowStatusVariableName and/or rndRowStatusObjectId must be a read-write MIB variable of type INTEGER which belongs to an entry (i.e, is a child of a MIB variable of type SEQUENCE)." ::= {rndDeleteValuesEntry 2} rndRowDeleteValue OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the variable identified by rndRowStatusVariableName and/or rndRowStatusObjectId, which, if present in a SNMP SET PDU, will cause the deletion of the conceptual row instance which the SET MIB variable instance belongs." ::= {rndDeleteValuesEntry 3} rndDeleteValueEntryStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "It is used to delete an entry from this table." ::= {rndDeleteValuesEntry 4} snmpTesting OBJECT IDENTIFIER ::= { rndMidLevelManagement 9} rndSimulatedVariablesTable OBJECT-TYPE SYNTAX SEQUENCE OF RndSimulatedVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table indicates which MIB variables are simulated." ::= {snmpTesting 1} rndSimulatedVariablesEntry OBJECT-TYPE SYNTAX RndSimulatedVariablesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The row definition for the rndSimulatedVariablesTable table." INDEX { rndSimulatedVariableEntryIndex } ::= {rndSimulatedVariablesTable 1} RndSimulatedVariablesEntry ::= SEQUENCE { rndSimulatedVariableEntryIndex INTEGER, rndSimulatedVariableObjectId OBJECT IDENTIFIER, rndNotSupportedField INTEGER, rndSimulatedVariableEntryStatus RowStatus } rndSimulatedVariableEntryIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The index entry." ::= {rndSimulatedVariablesEntry 1} rndSimulatedVariableObjectId OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-write STATUS current DESCRIPTION "The object id of the simulated variable. If the simulated variable belongs to a table entry, the entire entry is henceforth supported." ::= {rndSimulatedVariablesEntry 2} rndNotSupportedField OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Variable for not supported simulation." ::= {rndSimulatedVariablesEntry 3} rndSimulatedVariableEntryStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "It is used to delete an entry from this table." ::= {rndSimulatedVariablesEntry 4} rndSnmpTestPassword OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "This variable enables the user supplying the correct code to use the SNMP test feature." ::= {snmpTesting 2} rndSnmpTests OBJECT-TYPE SYNTAX INTEGER { noSimulation(1), simulateSetFailure(2), simulateAppGet(3), simulateAppGetNext(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable enables the authorized user to test various SNMP features." ::= {snmpTesting 3} rndSimulateUndo OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "This variable enables the authorized user to test the SNMP UNDO feature." ::= {snmpTesting 4} rlSnmpServTestRequest OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "This variable enables the authorized user to test the SNMP SERV package." ::= {snmpTesting 5} rlSnmpServTestResponse OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This variable enables the authorized user to retrieve the results of a the SNMP SERV package test." ::= {snmpTesting 6} rlSnmpServCreateTestPool OBJECT-TYPE SYNTAX INTEGER { create(1), no-create(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable enables the authorized user to indicate that after its reset the device should create a buffer pool for SNMPServ process PDU testing." ::= {snmpTesting 7} rlSnmpServITCbindClients OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-write STATUS current DESCRIPTION "This variable enables the authorized user to to indicate that after its reset the device should create ITC clients for SnmpServ data requests clients. The semantics of this variable is as follows: subidentifier 2*n indicates whether the client n is synchronous(1) or asynchronous(2) subidentifier 2*n+1 indicates the number of simulatneous requests expected by client n." ::= {snmpTesting 8} rlSnmpTestSimulatedVariables OBJECT IDENTIFIER ::= {snmpTesting 9} rlTstBasicRateTable OBJECT-TYPE SYNTAX SEQUENCE OF RlTstBasicRateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table for testing SNMP agent." ::= { snmpTesting 10 } rlTstBasicRateEntry OBJECT-TYPE SYNTAX RlTstBasicRateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the rlTstBasicRateTable." INDEX { ifIndex } ::= { rlTstBasicRateTable 1 } RlTstBasicRateEntry ::= SEQUENCE { rlTstBasicRateIfType INTEGER, rlTstBasicRateLineTopology INTEGER, rlTstBasicRateIfMode INTEGER, rlTstBasicRateSignalMode INTEGER } rlTstBasicRateIfType OBJECT-TYPE SYNTAX INTEGER { isdns(75), isdnu(76) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { rlTstBasicRateEntry 1 } rlTstBasicRateLineTopology OBJECT-TYPE SYNTAX INTEGER { pointToPoint(1), pointToMultipoint(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { rlTstBasicRateEntry 2 } rlTstBasicRateIfMode OBJECT-TYPE SYNTAX INTEGER { te(1), nt(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { rlTstBasicRateEntry 3 } rlTstBasicRateSignalMode OBJECT-TYPE SYNTAX INTEGER { active(1), inactive(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { rlTstBasicRateEntry 4 } rlMibTree OBJECT IDENTIFIER ::= {rndMidLevelManagement 10 } rlMibTreeTable OBJECT-TYPE SYNTAX SEQUENCE OF RlMibTreeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This reflects the MIB tree of the device." ::= {rlMibTree 1 } rlMibTreeEntry OBJECT-TYPE SYNTAX RlMibTreeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Each row shows a tree relationsship in the MIB." INDEX { rlMibTreeFather, rlMibTreeSonIndex } ::= {rlMibTreeTable 1 } RlMibTreeEntry ::= SEQUENCE { rlMibTreeFather DisplayString, rlMibTreeSonIndex INTEGER, rlMibTreeSon DisplayString, rlMibTreeSonObjectId OBJECT IDENTIFIER, rlMibTreeGrandFather DisplayString } rlMibTreeFather OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS not-accessible STATUS current DESCRIPTION " The father in a tree relation ship." ::= {rlMibTreeEntry 1 } rlMibTreeSonIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION " Running index for this table." ::= {rlMibTreeEntry 2 } rlMibTreeSon OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The son in a tree relation ship." ::= {rlMibTreeEntry 3 } rlMibTreeSonObjectId OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION " The object identifier of the son in a tree relation ship." ::= {rlMibTreeEntry 4} rlMibTreeGrandFather OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The grand father (i.e father's father) in a tree relation ship." ::= {rlMibTreeEntry 5 } rlMibInstances OBJECT IDENTIFIER ::= {rndMidLevelManagement 11 } rlMibTableInstancesInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF RlMibTableInstancesInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table for retreiving information on the current instances in a requested MIB table." ::= {rlMibInstances 1 } rlMibTableInstancesInfoEntry OBJECT-TYPE SYNTAX RlMibTableInstancesInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row with index rlMibTableInstancesInfoTableName = 'xTable' contains information on current instances in 'xTable'." INDEX { IMPLIED rlMibTableInstancesInfoTableName } ::= {rlMibTableInstancesInfoTable 1 } RlMibTableInstancesInfoEntry ::= SEQUENCE { rlMibTableInstancesInfoTableName DisplayString, rlMibTableInstancesInfoNumOfInstances INTEGER } rlMibTableInstancesInfoTableName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..160)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The name of the MIB table (for examle: snmpCommunityTable)" ::= {rlMibTableInstancesInfoEntry 1 } rlMibTableInstancesInfoNumOfInstances OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Get operation on this object will retreive the current number of instances in the MIB table specified by the index rlMibTableInstancesInfoTableName." ::= {rlMibTableInstancesInfoEntry 2 } -- Obsolete -- rsIpZeroHopRouting OBJECT IDENTIFIER ::= { rndApplications 3} rsPingMIB OBJECT IDENTIFIER ::= { rndApplications 4} -- NEW Group -------------------------------------------------------------------------------- -- rsPingTable -------------------------------------------------------------------------------- -- -- Textual Conventions -- PingCompletionStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "If all the echo request packets in this sequence have been responded by valid echo responses, this object is set to ok. Otherwise this status indicates the problem. bad-reply-data indicates that the reply data is not equal to the response data." SYNTAX INTEGER { ok(1), timeout(2), net-unreachable(3), host-unreachable(4), protocol-unreachable(5), time-to-live-exceeded(6), reassembly-time-exceeded(7), unable-to-send(8), bad-reply-data(9), incomplete(10) } rsPingTable OBJECT-TYPE SYNTAX SEQUENCE OF RsPingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of ping request entries." ::= { rsPingMIB 1 } rsPingEntry OBJECT-TYPE SYNTAX RsPingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A ping request entry. A management station wishing to create an entry should first generate a pseudo-random serial number to be used as the index to this sparse table. It must also create in the same PDU the associated instance of the address object. It should also modify in the same PDU the default values for the other configuration objects if the defaults are not appropriate. Once the sequence completes, the management station should retrieve the values of the status objects of interest, and should then delete the entry. In order to prevent old entries from clogging the table, entries will be aged out, but an entry will never be deleted within 5 minutes of completing." INDEX { rsPingAddress } ::= { rsPingTable 1 } RsPingEntry ::= SEQUENCE { rsPingAddress IpAddress, rsPingPacketCount INTEGER, rsPingPacketSize INTEGER, rsPingPacketTimeout INTEGER, rsPingDelay INTEGER, rsPingTrapOnCompletion TruthValue, rsPingSentPackets Counter32, rsPingReceivedPackets Counter32, rsPingMinReturnTime INTEGER, rsPingAvgReturnTime INTEGER, rsPingMaxReturnTime INTEGER, rsPingCompletionStatus PingCompletionStatus, rsPingTimeStamp DisplayString, rsPingEntryStatus RowStatus } rsPingAddress OBJECT-TYPE SYNTAX IpAddress -- Rsyntax OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "The address of the device to be pinged. Once an instance of this object is created, its value can not be changed." ::= { rsPingEntry 1 } rsPingPacketCount OBJECT-TYPE SYNTAX INTEGER(1..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the number of ping packets to send to the target in this sequence." -- DEFVAL { 5 } ::= { rsPingEntry 2 } rsPingPacketSize OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the size of ping packets to send to the target in this sequence. The lower and upper boundaries of this object are implementation dependent." -- DEFVAL { 100 } ::= { rsPingEntry 3 } rsPingPacketTimeout OBJECT-TYPE SYNTAX INTEGER(0..3600000) -- Units -- milliseconds MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the amount of time to wait for a response to a transmitted packet before declaring the packet 'dropped.'" -- DEFVAL { 2000 } ::= { rsPingEntry 4 } rsPingDelay OBJECT-TYPE SYNTAX INTEGER(0..3600000) -- Units -- milliseconds MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the minimum amount of time to wait before sending the next packet in a sequence after receiving a response. The actual delay may be greater due to internal task scheduling." -- DEFVAL { 0 } ::= { rsPingEntry 5 } rsPingTrapOnCompletion OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies whether or not a rsPingCompletion trap should be issued on completion of the sequence of pings. If such a trap is desired, the NMS should ensure that the community table contains an instance specified by the NMSs IP address with rndCommunityTrapsEnable = trapsEnable." -- DEFVAL { false } ::= { rsPingEntry 6 } rsPingSentPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ping packets that have been sent to the target in this sequence." ::= { rsPingEntry 7 } rsPingReceivedPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ping packets that have been received from the target in this sequence." ::= { rsPingEntry 8 } rsPingMinReturnTime OBJECT-TYPE SYNTAX INTEGER -- Units -- milliseconds MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum round trip time of all the packets that have been sent in this sequence. The value returned to a GET request is meaningless if no ping response in a sequence has been received yet." ::= { rsPingEntry 9 } rsPingAvgReturnTime OBJECT-TYPE SYNTAX INTEGER -- Units -- milliseconds MAX-ACCESS read-only STATUS current DESCRIPTION "The average round trip time of all the packets that have been sent in this sequence.The value returned to a GET request is meaningless if no ping response in a sequence has been received yet." ::= { rsPingEntry 10 } rsPingMaxReturnTime OBJECT-TYPE SYNTAX INTEGER -- Units -- milliseconds MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum round trip time of all the packets that have been sent in this sequence.The value returned to a GET request is meaningless if no ping response in a sequence has been received yet." ::= { rsPingEntry 11 } rsPingCompletionStatus OBJECT-TYPE SYNTAX PingCompletionStatus MAX-ACCESS read-only STATUS current DESCRIPTION "If all the echo request packets in this sequence have been responded by valid echo responses, this object is set to ok. Otherwise this status indicates the problem. bad-reply-data indicates that the reply data is not equal to the response data." ::= { rsPingEntry 12 } rsPingTimeStamp OBJECT-TYPE SYNTAX DisplayString(SIZE(19)) MAX-ACCESS read-only STATUS current DESCRIPTION "The time-stamp indicating the time and date of creation or last update of this request. The format of the time-stamp is dd/mm/yyyy hh:mm:ss" ::= { rsPingEntry 13 } rsPingEntryStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this table entry." ::= { rsPingEntry 14 } -------------------------------------------------------------------------------- -- rsPingInetTable -------------------------------------------------------------------------------- -- For IPv6 support -- Must replace old rsPingTable MIB rsPingInetTable OBJECT-TYPE SYNTAX SEQUENCE OF RsPingInetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of ping request entries." ::= { rsPingMIB 2 } rsPingInetEntry OBJECT-TYPE SYNTAX RsPingInetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A ping request entry. A management station wishing to create an entry should first generate a pseudo-random serial number to be used as the index to this sparse table. It must also create in the same PDU the associated instance of the address object. It should also modify in the same PDU the default values for the other configuration objects if the defaults are not appropriate. Once the sequence completes, the management station should retrieve the values of the status objects of interest, and should then delete the entry. In order to prevent old entries from clogging the table, entries will be aged out, but an entry will never be deleted within 5 minutes of completing." INDEX { rsPingInetAddressType, rsPingInetAddress } ::= { rsPingInetTable 1 } RsPingInetEntry ::= SEQUENCE { rsPingInetAddressType InetAddressType, rsPingInetAddress InetAddress, rsPingInetPacketCount INTEGER, rsPingInetPacketSize INTEGER, rsPingInetPacketTimeout INTEGER, rsPingInetDelay INTEGER, rsPingInetTrapOnCompletion TruthValue, rsPingInetSentPackets Counter32, rsPingInetReceivedPackets Counter32, rsPingInetMinReturnTime INTEGER, rsPingInetAvgReturnTime INTEGER, rsPingInetMaxReturnTime INTEGER, rsPingInetCompletionStatus PingCompletionStatus, rsPingInetTimeStamp DisplayString, rsPingInetEntryStatus RowStatus, rsPingInetSourceAddr InetAddress } rsPingInetAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-write STATUS current DESCRIPTION "The address type of the device to be pinged. Once an instance of this object is created, its value can not be changed." ::= { rsPingInetEntry 1 } rsPingInetAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The address of the device to be pinged. Once an instance of this object is created, its value can not be changed." ::= { rsPingInetEntry 2 } rsPingInetPacketCount OBJECT-TYPE SYNTAX INTEGER(1..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the number of ping packets to send to the target in this sequence." ::= { rsPingInetEntry 3 } rsPingInetPacketSize OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the size of ping packets to send to the target in this sequence. The lower and upper boundaries of this object are implementation dependent." ::= { rsPingInetEntry 4 } rsPingInetPacketTimeout OBJECT-TYPE SYNTAX INTEGER(0..3600000) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the amount of time (in milliseconds) to wait for a response to a transmitted packet before declaring the packet 'dropped.'" ::= { rsPingInetEntry 5 } rsPingInetDelay OBJECT-TYPE SYNTAX INTEGER(0..3600000) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the minimum amount of time (in milliseconds) to wait before sending the next packet in a sequence after receiving a response. The actual delay may be greater due to internal task scheduling." ::= { rsPingInetEntry 6 } rsPingInetTrapOnCompletion OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies whether or not a rsPingCompletion trap should be issued on completion of the sequence of pings. If such a trap is desired, the NMS should ensure that the community table contains an instance specified by the NMSs IP address with rndCommunityTrapsEnable = trapsEnable." ::= { rsPingInetEntry 7 } rsPingInetSentPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ping packets that have been sent to the target in this sequence." ::= { rsPingInetEntry 8 } rsPingInetReceivedPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ping packets that have been received from the target in this sequence." ::= { rsPingInetEntry 9 } rsPingInetMinReturnTime OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum round trip time (in milliseconds) of all the packets that have been sent in this sequence. The value returned to a GET request is meaningless if no ping response in a sequence has been received yet." ::= { rsPingInetEntry 10 } rsPingInetAvgReturnTime OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The average round trip time (in milliseconds) of all the packets that have been sent in this sequence.The value returned to a GET request is meaningless if no ping response in a sequence has been received yet." ::= { rsPingInetEntry 11 } rsPingInetMaxReturnTime OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum round trip time (in milliseconds) of all the packets that have been sent in this sequence.The value returned to a GET request is meaningless if no ping response in a sequence has been received yet." ::= { rsPingInetEntry 12 } rsPingInetCompletionStatus OBJECT-TYPE SYNTAX PingCompletionStatus MAX-ACCESS read-only STATUS current DESCRIPTION "If all the echo request packets in this sequence have been responded by valid echo responses, this object is set to ok. Otherwise this status indicates the problem. bad-reply-data indicates that the reply data is not equal to the response data." ::= { rsPingInetEntry 13 } rsPingInetTimeStamp OBJECT-TYPE SYNTAX DisplayString(SIZE(19)) MAX-ACCESS read-only STATUS current DESCRIPTION "The time-stamp indicating the time and date of creation or last update of this request. The format of the time-stamp is dd/mm/yyyy hh:mm:ss" ::= { rsPingInetEntry 14 } rsPingInetEntryStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this table entry." ::= { rsPingInetEntry 15 } rsPingInetSourceAddr OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this table entry." ::= { rsPingInetEntry 16 } -------------------------------------------------------------------------------- rsPowerSupplyRedundacy OBJECT IDENTIFIER ::= { rndApplications 5} -- NEW Group rsPowerSupplyRedundacyTable OBJECT-TYPE SYNTAX SEQUENCE OF RsPowerSupplyRedundacyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The power supply redundancy table." ::= { rsPowerSupplyRedundacy 1 } rsPowerSupplyRedundacyEntry OBJECT-TYPE SYNTAX RsPowerSupplyRedundacyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The status of power supply redundancy for this table." INDEX { rsPowerSupplyRedundacyReNumber} ::= { rsPowerSupplyRedundacyTable 1} RsPowerSupplyRedundacyEntry ::= SEQUENCE { rsPowerSupplyRedundacyReNumber INTEGER, rsPowerSupplyRedundacyStatus INTEGER } rsPowerSupplyRedundacyReNumber OBJECT-TYPE SYNTAX INTEGER (1..31) MAX-ACCESS read-only STATUS current DESCRIPTION "This number identifies the module backed up by power supply redundancy in the stack." ::= { rsPowerSupplyRedundacyEntry 1} rsPowerSupplyRedundacyStatus OBJECT-TYPE SYNTAX INTEGER{ notExist(1), existButNotWorking(2), bothWorking(3), internalOnlyWorking(4), externalOnlyWorking(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of a power supply redundancy of the entry." ::= { rsPowerSupplyRedundacyEntry 2} rsNvram OBJECT IDENTIFIER ::= { rndApplications 6 } rsEraseNvramAfterReset OBJECT-TYPE SYNTAX DisplayString (SIZE(0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of NVRAM application that will be erased after reset or ALL if all NVRAM should be erased." ::= { rsNvram 1 } rsNvramApplTable OBJECT-TYPE SYNTAX SEQUENCE OF RsNvramApplEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The NVRAM application table." ::= { rsNvram 2 } rsNvramApplEntry OBJECT-TYPE SYNTAX RsNvramApplEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The status of NVRAM application table." INDEX { rsNvramApplIndex} ::= { rsNvramApplTable 1} RsNvramApplEntry ::= SEQUENCE { rsNvramApplIndex INTEGER, rsNvramApplName DisplayString } rsNvramApplIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The index of NVRAM application table." ::= { rsNvramApplEntry 1} rsNvramApplName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of application used NVRAM." ::= { rsNvramApplEntry 2} END