--=========================================================== -- Copyright (C) 2003 New H3C Tech. Co., Ltd. All rights reserved. -- Description: This MIB is excerpted from the draft-ietf-hubmib-efm-epon-mib-02 directly --- only changed the object name,added the hh3c as prefix. -- Reference: -- Version: V1.0 -- History: -- V1.0 created by liyue. -- Define MODULE-IDENTITY for hh3cDot3EfmeponMIB --================================================================= HH3C-DOT3-EFM-EPON-MIB DEFINITIONS ::= BEGIN IMPORTS hh3cEpon FROM HH3C-OID-MIB MODULE-IDENTITY, mib-2, OBJECT-TYPE, Counter32, Integer32, OBJECT-IDENTITY FROM SNMPv2-SMI TruthValue, MacAddress FROM SNMPv2-TC ifIndex FROM IF-MIB MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF; hh3cDot3EfmeponMIB MODULE-IDENTITY LAST-UPDATED "200409210000Z" -- September 21, 2004 ORGANIZATION "New H3C Tech. Co., Ltd." CONTACT-INFO "Platform Team New H3C Tech. Co., Ltd. Hai-Dian District Beijing P.R. China http://www.h3c.com Zip:100085 " DESCRIPTION "The objects in this MIB module are used to manage the Ethernet in the First Mile (EFM) Multi Point Control Protocol (MPCP) Interfaces as defined in IEEE Draft P802.3ah/D3.0 clause 64,65. The following reference is used throughout this MIB module: [802.3ah] refers to: IEEE Draft P802.3ah/D3.3: 'Draft amendment to - Information technology - Telecommunications and information exchange between systems - Local and metropolitan area networks - Specific requirements - Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications - Media Access Control Parameters, Physical Layers and Management Parameters for subscriber access networks', 22 April 2004. Of particular interest are Clause 64(MPCP) 65(P2MP RS) and 60 (PON PMDs). Clause 30, 'Management', and Clause 45, 'Management Data Input/Output (MDIO) Interface'. Copyright (C) The Internet Society (2004). This version of this MIB module is part of XXXX see the RFC itself for full legal notices." -- Editor's Note: Replace XXXX with the actual RFC number -- assigned by RFC Editor and remove this note REVISION "200409210000Z" -- September 21, 2004 DESCRIPTION "Initial version, published as RFC XXXX." ::= { hh3cEpon 2 } -- Editor's Note: Replace XXX with a real OID once it is -- assigned by IANA and remove this note. -- Editor-s note: MPCP MIB modules definitions ([802.3ah] --- clause 30.3.5) -- Editor-s note: Description in attributes with References should be -- minimized in later versions hh3cDot3MpcpMIB OBJECT IDENTIFIER ::= { hh3cDot3EfmeponMIB 1 } hh3cDot3MpcpObjects OBJECT IDENTIFIER ::= { hh3cDot3MpcpMIB 1 } hh3cDot3MpcpConformance OBJECT IDENTIFIER ::= { hh3cDot3MpcpMIB 2 } hh3cDot3MpcpTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cDot3MpcpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table for dot3 Multi-Point Control Protocol (MPCP) MIB modules." ::= { hh3cDot3MpcpObjects 1 } hh3cDot3MpcpEntry OBJECT-TYPE SYNTAX Hh3cDot3MpcpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot3 MPCP MIB modules table." INDEX { ifIndex } ::= { hh3cDot3MpcpTable 1 } Hh3cDot3MpcpEntry ::= SEQUENCE { hh3cDot3MpcpID Integer32, hh3cDot3MpcpOperStatus TruthValue, hh3cDot3MpcpMode INTEGER, hh3cDot3MpcpLinkID Integer32, hh3cDot3MpcpRemoteMACAddress MacAddress, hh3cDot3MpcpRegistrationState INTEGER, hh3cDot3MpcpTransmitElapsed Integer32, hh3cDot3MpcpReceiveElapsed Integer32, hh3cDot3MpcpRoundTripTime Integer32, hh3cDot3MpcpMaximumPendingGrants Integer32, hh3cDot3MpcpAdminState TruthValue, hh3cDot3MpcpOnTime Integer32, hh3cDot3MpcpOffTime Integer32, hh3cDot3MpcpSyncTime Integer32 } hh3cDot3MpcpID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This variable is assigned so as to uniquely identify the Multi-Point MAC Control (MPCP) entity, as defined in [802.3ah] clause 64, among the subordinate managed objects of the containing object. This attribute is relevant for an OLT and an ONU." REFERENCE "[802.3ah], 30.3.5.1.1." ::= { hh3cDot3MpcpEntry 1 } hh3cDot3MpcpOperStatus OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This variable can be used to define the operational state of the Multi-Point MAC Control sublayer as defined in [802.3ah] clause 64. Selecting admin for an interface with Multi-Point MAC Control sublayer. When the attribute is True the the interface will act as if Multi-point control protocol is enabled. When the attribute is False the interface will act as if it does not have the Multi-point control protocol. The operational state can be changed using the hh3cDot3MpcpAdminState attribute. This attribute is relevant for an OLT and an ONU." REFERENCE "[802.3ah], 30.3.5.1.2." ::= { hh3cDot3MpcpEntry 2 } hh3cDot3MpcpMode OBJECT-TYPE SYNTAX INTEGER { olt(1), onu(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable can be used to identify the operational state of the Multi-Point MAC Control sublayer as defined in [802.3ah] clause 64. Selecting olt(1) for an OLT (server) mode and onu(2) for an ONU (client) mode. Writing can be done during only during initialization, when hh3cDot3MpcpOperStatus indicates Flase. This attribute is relevant for an OLT and an ONU." REFERENCE "[802.3ah], 30.3.5.1.3." DEFVAL { 1 } ::= { hh3cDot3MpcpEntry 3 } hh3cDot3MpcpLinkID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only value that identifies the Logical Link identity (LLID) associated with the MAC port as specified in [802.3ah] clause 65.1.3.2.2. This attribute is relevant for an OLT and an ONU." REFERENCE "[802.3ah], 30.3.5.1.4." ::= { hh3cDot3MpcpEntry 4 } hh3cDot3MpcpRemoteMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only value that identifies the source_address parameter of the last MPCPDUs passed to the MAC Control. This value is updated on reception of a valid frame with (1) a destination Field equal to the reserved multicast address for MAC Control specified in [802.3ah] Annex 31A, (2) lengthOrType field value equal to the reserved Type for MAC Control as specified in [802.3ah] Annex 31A. (3) an MPCP subtype value equal to the subtype reserved for MPCP as specified in [802.3ah] Annex 31A. This attribute is relevant for an OLT and an ONU." REFERENCE "[802.3ah], 30.3.5.1.5." ::= { hh3cDot3MpcpEntry 5 } hh3cDot3MpcpRegistrationState OBJECT-TYPE SYNTAX INTEGER { unregistered(1), registering(2), registered(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only value that identifies the operational state of the Multi-Point MAC Control sublayer as defined in [802.3ah] clause 64. When this attribute has the enumeration unregistered(1) the interface may be used for registering a link partner. When this attribute has the enumeration registering(2) the interface is in the process of registering a link-partner. When this attribute has the enumeration registered(3) the interface has an established link-partner. This attribute is relevant for an OLT and an ONU. For the OLT it provides an indication per LLID." REFERENCE "[802.3ah], 30.3.5.1.6." ::= { hh3cDot3MpcpEntry 6 } hh3cDot3MpcpTransmitElapsed OBJECT-TYPE SYNTAX Integer32 UNITS "TQ (16nsec)" MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only value that reports the interval from last MPCP frame transmission in increments of Time Quanta (TQ) 16ns. The value returned shall be (interval from last MPCP frame transmission in ns)/16. If this value exceeds (2^32-1) the value (2^32-1) shall be returned. This attribute is relevant for an OLT and an ONU." REFERENCE "[802.3ah], 30.3.5.1.19." ::= { hh3cDot3MpcpEntry 7 } hh3cDot3MpcpReceiveElapsed OBJECT-TYPE SYNTAX Integer32 UNITS "TQ (16nsec)" MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only value that reports the interval from last MPCP frame reception in increments of Time Quanta (TQ) 16ns. The value returned shall be (interval from last MPCP last MPCP frame reception in ns)/16. If this value exceeds (2^32-1) the value (2^32-1) shall be returned. This attribute is relevant for an OLT and an ONU." REFERENCE "[802.3ah], 30.3.5.1.20." ::= { hh3cDot3MpcpEntry 8 } hh3cDot3MpcpRoundTripTime OBJECT-TYPE SYNTAX Integer32 UNITS "TQ (16nsec)" MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only value that reports the MPCP round trip time in increments of Time Quanta (TQ) 16ns. The value returned shall be (round trip time in ns)/16. If this value exceeds (2^16-1) the value (2^16-1) shall be returned. This attribute is relevant for an OLT and an ONU. For the OLT there is a value per LLID" REFERENCE "[802.3ah], 30.3.5.1.21." ::= { hh3cDot3MpcpEntry 9 } hh3cDot3MpcpMaximumPendingGrants OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only value that indicates the maximum number of grants an ONU can store. The maximum number of grants an ONU can store has a range of 0 to 255. This attribute is relevant for an OLT and an ONU. For the OLT there is a value per LLID" REFERENCE "[802.3ah], 30.3.5.1.24." ::= { hh3cDot3MpcpEntry 10 } hh3cDot3MpcpAdminState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This variable can be used to define the operational state of the Multi-Point MAC Control sublayer as defined in [802.3ah] clause 64. Selecting admin for an interface with Multi-Point MAC Control sublayer. When selecting the value as True the interface Multi-Point control protocol is enabled. When selecting the value as False the interface acts as if the Multi-point Control protocol does not exist. Reading reflects the state of the attribute and the operation of the Multi-point control protocol mode of the interface. Writing can be done all the time. This attribute is relevant for an OLT and an ONU." REFERENCE "[802.3ah], 30.3.5.2.1." DEFVAL { false } ::= { hh3cDot3MpcpEntry 11 } hh3cDot3MpcpOnTime OBJECT-TYPE SYNTAX Integer32 UNITS "TQ (16nsec)" MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only value that reports the -on time- for a grant burst in increments of Time Quanta (TQ) 16ns as defined in [802.3ah] 60,64. The value returned shall be (on time ns)/16. If this value exceeds (2^32-1) the value (2^32-1) shall be returned. This attribute is relevant for an OLT and an ONU." REFERENCE "[802.3ah], 64.3.5.1." ::= { hh3cDot3MpcpEntry 12 } hh3cDot3MpcpOffTime OBJECT-TYPE SYNTAX Integer32 UNITS "TQ (16nsec)" MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only value that reports the -off time- for a grant burst in increments of Time Quanta (TQ) 16ns as defined in [802.3ah] 60,64. The value returned shall be (off time ns)/16. If this value exceeds (2^32-1) the value (2^32-1) shall be returned. This attribute is relevant for an OLT and an ONU." REFERENCE "[802.3ah], 64.3.5.1." ::= { hh3cDot3MpcpEntry 13 } hh3cDot3MpcpSyncTime OBJECT-TYPE SYNTAX Integer32 UNITS "TQ (16nsec)" MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only value that reports the -sync lock time- for an OLT receiver in increments of Time Quanta (TQ) 16ns as defined in [802.3ah] 60,64,65. The value returned shall be (sync lock time ns)/16. If this value exceeds (2^32-1) the value (2^32-1) shall be returned. This attribute is relevant for an OLT and an ONU." REFERENCE "[802.3ah], 64.3.3.2." ::= { hh3cDot3MpcpEntry 14 } hh3cDot3MpcpStatTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cDot3MpcpStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines the list of statistics counters of [802.3ah] clause 64 MPCP interface." ::= { hh3cDot3MpcpObjects 2 } hh3cDot3MpcpStatEntry OBJECT-TYPE SYNTAX Hh3cDot3MpcpStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table entries for table of statistics counters of [802.3ah] clause 64 MPCP interface." INDEX { ifIndex } ::= { hh3cDot3MpcpStatTable 1 } Hh3cDot3MpcpStatEntry ::= SEQUENCE { hh3cDot3MpcpMACCtrlFramesTransmitted Counter32, hh3cDot3MpcpMACCtrlFramesReceived Counter32, hh3cDot3MpcpDiscoveryWindowsSent Counter32, hh3cDot3MpcpDiscoveryTimeout Counter32, hh3cDot3MpcpTxRegRequest Counter32, hh3cDot3MpcpRxRegRequest Counter32, hh3cDot3MpcpTxRegAck Counter32, hh3cDot3MpcpRxRegAck Counter32, hh3cDot3MpcpTxReport Counter32, hh3cDot3MpcpRxReport Counter32, hh3cDot3MpcpTxGate Counter32, hh3cDot3MpcpRxGate Counter32, hh3cDot3MpcpTxRegister Counter32, hh3cDot3MpcpRxRegister Counter32, hh3cDot3MpcpRxNotSupportedMPCP Counter32 } hh3cDot3MpcpMACCtrlFramesTransmitted OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of MPCP frames passed to the MAC sublayer for transmission. This counter is incremented when a MA_CONTROL.request service primitive is generated within the MAC control sublayer with an opcode indicating a MPCP frame. This attribute is relevant for an OLT and an ONU." REFERENCE "[802.3ah], 30.3.5.1.7." ::= { hh3cDot3MpcpStatEntry 1 } hh3cDot3MpcpMACCtrlFramesReceived OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of MPCP frames passed by the MAC sublayer to the MAC Control sublayer. This counter is incremented when a ReceiveFrame function call returns a valid frame with: (1) a lengthOrType field value equal to the reserved Type for 802.3_MAC_Control as specified in 31.4.1.3, and (2) an opcode indicating a MPCP frame. This attribute is relevant for an OLT and an ONU." REFERENCE "[802.3ah], 30.3.5.1.8." ::= { hh3cDot3MpcpStatEntry 2 } hh3cDot3MpcpDiscoveryWindowsSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of discovery windows generated. The counter is incremented by one for each generated discovery window. This attribute is relevant for an OLT and an ONU. At the ONU value should be zero." REFERENCE "[802.3ah], 30.3.5.1.22." ::= { hh3cDot3MpcpStatEntry 3 } hh3cDot3MpcpDiscoveryTimeout OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a discovery timeout occurs. Increment the counter by one for each discovery processing state-machine reset resulting from timeout waiting for message arrival. This attribute is relevant for an OLT and an ONU." REFERENCE "[802.3ah], 30.3.5.1.23." ::= { hh3cDot3MpcpStatEntry 4 } hh3cDot3MpcpTxRegRequest OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a REGISTER_REQ MPCP frames transmission occurs. Increment the counter by one for each REGISTER_REQ MPCP frame transmitted as defined in [802.3ah] clause 64. This counter is mandatory for an ONU. This attribute is relevant for an OLT and an ONU. At the OLT value should be zero." REFERENCE "[802.3ah], 30.3.5.1.12." ::= { hh3cDot3MpcpStatEntry 5 } hh3cDot3MpcpRxRegRequest OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a REGISTER_REQ MPCP frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each REGISTER_REQ MPCP frame received for each LLID as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and for an OLT. At the ONU value should be zero." REFERENCE "[802.3ah], 30.3.5.1.17." ::= { hh3cDot3MpcpStatEntry 6 } hh3cDot3MpcpTxRegAck OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a REGISTER_ACK MPCP frames transmission occurs. Increment the counter by one for each REGISTER_ACK MPCP frame transmitted as defined in [802.3ah] clause 64. This counter is mandatory for an ONU. This attribute is relevant for an OLT and an ONU. At the OLT the value should be zero." REFERENCE "[802.3ah], 30.3.5.1.10." ::= { hh3cDot3MpcpStatEntry 7 } hh3cDot3MpcpRxRegAck OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a REGISTER_ACK MPCP frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each REGISTER_ACK MPCP frame received for each LLID, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and for an OLT. At the ONU the value should be zero." REFERENCE "[802.3ah], 30.3.5.1.15." ::= { hh3cDot3MpcpStatEntry 8 } hh3cDot3MpcpTxReport OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a REPORT MPCP frames transmission occurs. Increment the counter by one for each REPORT MPCP frame transmitted as defined in [802.3ah] clause 64. This counter is mandatory for an ONU. This attribute is relevant for an OLT and an ONU. At the OLT value should be zero." REFERENCE "[802.3ah], 30.3.5.1.13." ::= { hh3cDot3MpcpStatEntry 9 } hh3cDot3MpcpRxReport OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a REPORT MPCP frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each REPORT MPCP frame received for each LLID, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and for an OLT. At the ONU value should be zero." REFERENCE "[802.3ah], 30.3.5.1.18." ::= { hh3cDot3MpcpStatEntry 10 } hh3cDot3MpcpTxGate OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a GATE MPCP frames transmission occurs. A set of counters, one for each LLID, at the OLT. Increment the counter by one for each GATE MPCP frame transmitted, for each LLID, as defined in [802.3ah] clause 64. This counter is mandatory for an OLT. This attribute is relevant for an OLT and an ONU. At the ONU the value should be zero." REFERENCE "[802.3ah], 30.3.5.1.9." ::= { hh3cDot3MpcpStatEntry 11 } hh3cDot3MpcpRxGate OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a GATE MPCP frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID ,at the OLT. Increment the counter by one for each GATE MPCP frame received, for each LLID, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and for an OLT. At the OLT the value should be zero." REFERENCE "[802.3ah], 30.3.5.1.14." ::= { hh3cDot3MpcpStatEntry 12 } hh3cDot3MpcpTxRegister OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a REGISTER MPCP frames transmission occurs. A set of counters, one for each LLID, at the OLT. Increment the counter by one for each REGISTER MPCP frame transmitted, for each LLID, as defined in [802.3ah] clause 64. This counter is mandatory for an OLT. This attribute is relevant for an OLT and an ONU. At the ONU the value should be zero." REFERENCE "[802.3ah], 30.3.5.1.11." ::= { hh3cDot3MpcpStatEntry 13 } hh3cDot3MpcpRxRegister OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a REGISTER MPCP frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each REGISTER MPCP frame received, for each LLID, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and for an OLT. at the OLT the value should be zero." REFERENCE "[802.3ah], 30.3.5.1.16." ::= { hh3cDot3MpcpStatEntry 14 } hh3cDot3MpcpRxNotSupportedMPCP OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a non-supported MPCP frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each non-supported MPCP frame received, for each LLID, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and for an OLT." ::= { hh3cDot3MpcpStatEntry 15 } -- Conformance Statements -- Conformance Groups hh3cDot3MpcpGroups OBJECT IDENTIFIER ::= { hh3cDot3MpcpConformance 1 } hh3cDot3MpcpGroupBase OBJECT-GROUP OBJECTS { hh3cDot3MpcpID, hh3cDot3MpcpOperStatus, hh3cDot3MpcpMode, hh3cDot3MpcpLinkID, hh3cDot3MpcpRemoteMACAddress, hh3cDot3MpcpRegistrationState, hh3cDot3MpcpMaximumPendingGrants, hh3cDot3MpcpAdminState } STATUS current DESCRIPTION "A collection of objects of dot3 Mpcp Basic entity state definition." ::= { hh3cDot3MpcpGroups 1 } hh3cDot3MpcpGroupParam OBJECT-GROUP OBJECTS { hh3cDot3MpcpTransmitElapsed, hh3cDot3MpcpReceiveElapsed, hh3cDot3MpcpRoundTripTime, hh3cDot3MpcpOnTime, hh3cDot3MpcpOffTime, hh3cDot3MpcpSyncTime } STATUS current DESCRIPTION "A collection of objects of dot3 Mpcp for P2MP parameters." ::= { hh3cDot3MpcpGroups 2 } hh3cDot3MpcpGroupStat OBJECT-GROUP OBJECTS { hh3cDot3MpcpMACCtrlFramesTransmitted, hh3cDot3MpcpMACCtrlFramesReceived, hh3cDot3MpcpDiscoveryWindowsSent, hh3cDot3MpcpDiscoveryTimeout , hh3cDot3MpcpTxRegRequest, hh3cDot3MpcpRxRegRequest, hh3cDot3MpcpTxRegAck, hh3cDot3MpcpRxRegAck, hh3cDot3MpcpTxReport, hh3cDot3MpcpRxReport, hh3cDot3MpcpTxGate, hh3cDot3MpcpRxGate, hh3cDot3MpcpTxRegister, hh3cDot3MpcpRxRegister, hh3cDot3MpcpRxNotSupportedMPCP } STATUS current DESCRIPTION "A collection of objects of dot3 Mpcp Statistics" ::= { hh3cDot3MpcpGroups 3 } -- Compliance hh3cDot3MpcpCompliances OBJECT IDENTIFIER ::= { hh3cDot3MpcpConformance 2 } hh3cDot3MpcpCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for Multi-point control protocol interfaces." MODULE -- this module MANDATORY-GROUPS { hh3cDot3MpcpGroupBase } GROUP hh3cDot3MpcpGroupParam DESCRIPTION "This group is mandatory for all MPCP supporting interfaces for configuration of the Multipoint Parameters." GROUP hh3cDot3MpcpGroupStat DESCRIPTION "This group is mandatory for all MPCP supporting interfaces for Statistics collection." ::= { hh3cDot3MpcpCompliances 1 } -- Editor-s note: OMPEmulation managed object definitions hh3cDot3OmpEmulationMIB OBJECT IDENTIFIER ::= { hh3cDot3EfmeponMIB 2 } hh3cDot3OmpEmulationObjects OBJECT IDENTIFIER ::= { hh3cDot3OmpEmulationMIB 1 } hh3cDot3OmpeConformance OBJECT IDENTIFIER ::= { hh3cDot3OmpEmulationMIB 2 } hh3cDot3OmpEmulationTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cDot3OmpEmulationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table for dot3 OmpEmulation MIB modules." ::= { hh3cDot3OmpEmulationObjects 1 } hh3cDot3OmpEmulationEntry OBJECT-TYPE SYNTAX Hh3cDot3OmpEmulationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot3 OmpEmulation MIB modules table." INDEX { ifIndex } ::= { hh3cDot3OmpEmulationTable 1 } Hh3cDot3OmpEmulationEntry ::= SEQUENCE { hh3cDot3OmpEmulationID Integer32, hh3cDot3OmpEmulationType INTEGER } hh3cDot3OmpEmulationID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of hh3cDot3OmpEmulationID is assigned so as to uniquely identify a OMPEmulation entity among the subordinate managed objects of the containing object. The value is mandated for an ONU." REFERENCE "[802.3ah], 30.3.7.1.1." ::= { hh3cDot3OmpEmulationEntry 1 } hh3cDot3OmpEmulationType OBJECT-TYPE SYNTAX INTEGER { unknown(1), olt(2), onu(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only value that indicates that mode of operation of the Reconciliation Sublayer for Point to Point Emulation (see [802.3ah] clause 65.1). unknown(1) value is assigned in initializing, true state or type not yet known. olt(2) value is assigned when Sublayer operating in OLT mode. onu(3) value is assigned when Sublayer operating in ONU mode." REFERENCE "[802.3ah], 30.3.7.1.2." ::= { hh3cDot3OmpEmulationEntry 2 } hh3cDot3OmpEmulationStatTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cDot3OmpEmulationStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines the list of statistics counters of [802.3ah] clause 65 OMP interface." ::= { hh3cDot3OmpEmulationObjects 2 } hh3cDot3OmpEmulationStatEntry OBJECT-TYPE SYNTAX Hh3cDot3OmpEmulationStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table entries for Table of statistics counters of [802.3ah] clause 65 OMP interface." INDEX { ifIndex } ::= { hh3cDot3OmpEmulationStatTable 1 } Hh3cDot3OmpEmulationStatEntry ::= SEQUENCE { hh3cDot3OmpEmulationSLDErrors Counter32, hh3cDot3OmpEmulationCRC8Errors Counter32, hh3cDot3OmpEmulationBadLLID Counter32, hh3cDot3OmpEmulationGoodLLID Counter32, hh3cDot3OmpEmulationOnuPonCastLLID Counter32, hh3cDot3OmpEmulationOltPonCastLLID Counter32, hh3cDot3OmpEmulationBroadcastLLIDNotOnuID Counter32, hh3cDot3OmpEmulationOnuLLIDNotBroadcast Counter32, hh3cDot3OmpEmulationBroadcastLLIDPlusOnuId Counter32, hh3cDot3OmpEmulationNotBroadcastLLIDNotOnuId Counter32 } hh3cDot3OmpEmulationSLDErrors OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that do not contain a valid SLD field as defined in [802.3ah] clause 65.1.3.3.1. This attribute is mandatory for an OLT and optional for an ONU." REFERENCE "[802.3ah], 30.3.7.1.3." ::= { hh3cDot3OmpEmulationStatEntry 1 } hh3cDot3OmpEmulationCRC8Errors OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that contain a valid SLD field, as defined in [802.3ah] clause 65.1.3.3.1, but do not pass the CRC-8 check as defined in [802.3ah] clause 65.1.3.3.3. This attribute is mandatory for an OLT and for an ONU." REFERENCE "[802.3ah], 30.3.7.1.4." ::= { hh3cDot3OmpEmulationStatEntry 2 } hh3cDot3OmpEmulationBadLLID OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that contain a valid SLD field, as defined in [802.3ah] clause 65.1.3.3.1, and pass the CRC-8 check, as defined in [802.3ah] clause 65.1.3.3.3, but are discarded due to the LLID check as defined in [802.3ah] clause 65.1.3.3.2. This attribute is relevant for an OLT and an ONU." REFERENCE "[802.3ah], 30.3.7.1.8." ::= { hh3cDot3OmpEmulationStatEntry 3 } hh3cDot3OmpEmulationGoodLLID OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that contain a valid SLD field, as defined in [802.3ah] clause 65.1.3.3.1, and pass the CRC-8 check, as defined in [802.3ah] clause 65.1.3.3.3. This attribute is relevant for an OLT and an ONU." REFERENCE "[802.3ah], 30.3.7.1.5." ::= { hh3cDot3OmpEmulationStatEntry 4 } hh3cDot3OmpEmulationOnuPonCastLLID OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that contain a valid SLD field in an ONU, as defined in [802.3ah] 65.1.3.3.1, passes the CRC-8 check, as defined in [802.3ah] 65.1.3.3.3, and the frame meets the rule for acceptance defined in [802.3ah] 65.1.3.3.2." REFERENCE "[802.3ah], 30.3.7.1.6." ::= { hh3cDot3OmpEmulationStatEntry 5 } hh3cDot3OmpEmulationOltPonCastLLID OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that contain a valid SLD field in an OLT, as defined in [802.3ah] 65.1.3.3.1, passes the CRC-8 check, as defined in [802.3ah] 65.1.3.3.3, and the frame meets the rule for acceptance defined in [802.3ah] 65.1.3.3.2." REFERENCE "[802.3ah], 30.3.7.1.7." ::= { hh3cDot3OmpEmulationStatEntry 6 } hh3cDot3OmpEmulationBroadcastLLIDNotOnuID OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that contain a valid SLD field in a OLT, as defined in [802.3ah] clause 65.1.3.3.1, and pass the CRC-8 check, as defined in [802.3ah] clause 65.1.3.3.3, and contain broadcast LLID as defined in [802.3ah] clause 65. This attribute is mandatory for an OLT and for an ONU." ::= { hh3cDot3OmpEmulationStatEntry 7 } hh3cDot3OmpEmulationOnuLLIDNotBroadcast OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that contain a valid SLD field in a OLT, as defined in [802.3ah] clause 65.1.3.3.1, and pass the CRC-8 check, as defined in [802.3ah] clause 65.1.3.3.3, and contain the ONU's LLID as defined in [802.3ah] clause 65. This attribute is mandatory for an ONU and mandatory for an OLT (a counter per LLID)." ::= { hh3cDot3OmpEmulationStatEntry 8 } hh3cDot3OmpEmulationBroadcastLLIDPlusOnuId OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that contain a valid SLD field in a OLT, as defined in [802.3ah] clause 65.1.3.3.1, and pass the CRC-8 check, as defined in [802.3ah] clause 65.1.3.3.3, and contain the broadcast LLID plus ONU's LLID (frame reflected) as defined in [802.3ah] clause 65. This attribute is mandatory for an ONU and mandatory for an OLT (a counter per LLID)." ::= { hh3cDot3OmpEmulationStatEntry 9 } hh3cDot3OmpEmulationNotBroadcastLLIDNotOnuId OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of frames received that contain a valid SLD field in a OLT, as defined in [802.3ah] clause 65.1.3.3.1, and pass the CRC-8 check, as defined in [802.3ah] clause 65.1.3.3.3, and does not contain the ONU's LLID as defined in [802.3ah] clause 65. This attribute is mandatory for an ONU" ::= { hh3cDot3OmpEmulationStatEntry 10 } -- Conformance Statements -- Conformance Groups hh3cDot3OmpeGroups OBJECT IDENTIFIER ::= { hh3cDot3OmpeConformance 1 } hh3cDot3OmpeGroupID OBJECT-GROUP OBJECTS { hh3cDot3OmpEmulationID, hh3cDot3OmpEmulationType } STATUS current DESCRIPTION "A collection of objects of dot3 OMP emulation ID entity state definition." ::= { hh3cDot3OmpeGroups 1 } hh3cDot3OmpeGroupStat OBJECT-GROUP OBJECTS { hh3cDot3OmpEmulationSLDErrors, hh3cDot3OmpEmulationCRC8Errors, hh3cDot3OmpEmulationBadLLID, hh3cDot3OmpEmulationGoodLLID, hh3cDot3OmpEmulationOnuPonCastLLID, hh3cDot3OmpEmulationOltPonCastLLID, hh3cDot3OmpEmulationBroadcastLLIDNotOnuID, hh3cDot3OmpEmulationOnuLLIDNotBroadcast, hh3cDot3OmpEmulationBroadcastLLIDPlusOnuId, hh3cDot3OmpEmulationNotBroadcastLLIDNotOnuId } STATUS current DESCRIPTION "A collection of objects of dot3 OMP emulation Statistics" ::= { hh3cDot3OmpeGroups 2 } -- Compliance hh3cDot3OmpeCompliances OBJECT IDENTIFIER ::= { hh3cDot3OmpeConformance 2 } hh3cDot3OmpeCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for OMPEmulation interfaces." MODULE -- this module MANDATORY-GROUPS { hh3cDot3OmpeGroupID } GROUP hh3cDot3OmpeGroupStat DESCRIPTION "This group is mandatory for all OMPemulation supporting interfaces for Statistics collection." ::= { hh3cDot3OmpeCompliances 1 } -- Editor-s note: MAU managed object definitions (30.5.1) hh3cDot3EponMauMIB OBJECT IDENTIFIER ::= { hh3cDot3EfmeponMIB 3 } hh3cDot3EponMauObjects OBJECT IDENTIFIER ::= { hh3cDot3EponMauMIB 1 } hh3cDot3EponMauConformance OBJECT IDENTIFIER ::= { hh3cDot3EponMauMIB 2 } hh3cDot3EponMauTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cDot3EponMauEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table for dot3 MAU EPON MIB modules." ::= { hh3cDot3EponMauObjects 1 } hh3cDot3EponMauEntry OBJECT-TYPE SYNTAX Hh3cDot3EponMauEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot3 MAU EPON MIB modules table." INDEX { ifIndex } ::= { hh3cDot3EponMauTable 1 } Hh3cDot3EponMauEntry ::= SEQUENCE { hh3cDot3EponMauPCSCodingViolation Counter32, hh3cDot3EponMauFecAbility INTEGER, hh3cDot3EponMauFecMode INTEGER, hh3cDot3EponMauFECCorrectedBlocks Counter32, hh3cDot3EponMauFECUncorrectableBlocks Counter32, hh3cDot3EponMauBufferHeadCodingViolation Counter32 } hh3cDot3EponMauPCSCodingViolation OBJECT-TYPE SYNTAX Counter32 UNITS "octets" MAX-ACCESS read-only STATUS current DESCRIPTION "For 100 Mb/ s operation it is a count of the number of times an invalid code-group is received, other than the /H/ code-group. For 1000 Mb/ s operation it is a count of the number of times an invalid codegroup is received, other than the /V/ code-group." REFERENCE "[802.3ah], 30.5.1.1.12." ::= { hh3cDot3EponMauEntry 1 } hh3cDot3EponMauFecAbility OBJECT-TYPE SYNTAX INTEGER { unknown (1), nonsupported (2), supported (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only value that indicates the support of operation of the 1000BASE-PX PHY optional FEC Sublayer for Forward error correction see [802.3ah] clause 65.2). unknown(1) value is assigned in initializing, for non FEC support state or type not yet known. nonsupported(2) value is assigned when Sublayer is not support. supported(3) value is assigned when Sublayer is supported." REFERENCE "[802.3ah], 30.5.1.1.13." ::= { hh3cDot3EponMauEntry 2 } hh3cDot3EponMauFecMode OBJECT-TYPE SYNTAX INTEGER { unknown (1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "A read-write value that indicates the mode of operation of the 1000BASE-PX PHY optional FEC Sublayer for Forward error correction see [802.3ah] clause 65.2). A GET operation returns the current mode of operation the PHY. A SET operation changes the mode of operation of the PHY to the indicated value. unknown(1) value is assigned in initializing, for non FEC support state or type not yet known. disabled(2) value is assigned when Sublayer operating in disabled mode. enabled(3) value is assigned when Sublayer operating in FEC mode. writing can be done all the time." REFERENCE "[802.3ah], 30.5.1.1.14." DEFVAL { 1 } ::= { hh3cDot3EponMauEntry 3 } hh3cDot3EponMauFECCorrectedBlocks OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "For 10PASS-TS, 2BASE-TL and 1000BASE-PX PHYs, a count of corrected FEC blocks. This counter will not increment for other PHY Types. Increment the counter by one for each received block that is corrected by the FEC function in the PHY." REFERENCE "[802.3ah], 30.5.1.1.15." ::= { hh3cDot3EponMauEntry 4 } hh3cDot3EponMauFECUncorrectableBlocks OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "For 10PASS-TS, 2BASE-TL and 1000BASE-PX PHYs, a count of uncorrectable FEC blocks. This counter will not increment for other PHY Types. Increment the counter by one for each FEC block that is determined to be uncorrectable by the FEC function in the PHY." REFERENCE "[802.3ah], 30.5.1.1.16." ::= { hh3cDot3EponMauEntry 5 } hh3cDot3EponMauBufferHeadCodingViolation OBJECT-TYPE SYNTAX Counter32 UNITS "octets" MAX-ACCESS read-only STATUS current DESCRIPTION "For 1000 Mbps operation it is a counts of the number of invalid code-group received directly from the link." ::= { hh3cDot3EponMauEntry 6 } -- Defining EPON MAU types -- Editor's Note: This section should be added to 802.3 MAU MIB -- module RFC. Preference would be that the MAU MIB module -- structure would change so that it is re-written as an -- IANA-maintained module. hh3cDot3EponMauType OBJECT IDENTIFIER ::= { hh3cDot3EponMauMIB 3 } hh3cEponMauType1000BasePXOLT OBJECT-IDENTITY STATUS current DESCRIPTION "Multipoint MAC Control (per 802.3 section 64,65) OLT (master), unknown PMD" REFERENCE "[802.3ah], 30.5.1.1.2." ::= { hh3cDot3EponMauType 1 } hh3cEponMauType1000BasePXONU OBJECT-IDENTITY STATUS current DESCRIPTION "Multipoint MAC Control (per 802.3 section 64,65),ONU (slave), unknown PMD" REFERENCE "[802.3ah], 30.5.1.1.2." ::= { hh3cDot3EponMauType 2 } hh3cEponMauType1000BasePX10DOLT OBJECT-IDENTITY STATUS current DESCRIPTION "EPON over 10K link, downlink (per 802.3 section 60), OLT side" REFERENCE "[802.3ah], 30.5.1.1.2." ::= { hh3cDot3EponMauType 3 } hh3cEponMauType1000BasePX10DONU OBJECT-IDENTITY STATUS current DESCRIPTION "EPON over 10K link, downlink (per 802.3 section 60), ONU side" REFERENCE "[802.3ah], 30.5.1.1.2." ::= { hh3cDot3EponMauType 4 } hh3cEponMauType1000BasePX10UOLT OBJECT-IDENTITY STATUS current DESCRIPTION "EPON over 10K link, uplink (per 802.3 section 60), OLT side" REFERENCE "[802.3ah], 30.5.1.1.2." ::= { hh3cDot3EponMauType 5 } hh3cEponMauType1000BasePX10UONU OBJECT-IDENTITY STATUS current DESCRIPTION "EPON over 10K link, uplink (per 802.3 section 60), ONU side" REFERENCE "[802.3ah], 30.5.1.1.2." ::= { hh3cDot3EponMauType 6 } hh3cEponMauType1000BasePX20DOLT OBJECT-IDENTITY STATUS current DESCRIPTION "EPON over 20K link, downlink (per 802.3 section 60), OLT side" REFERENCE "[802.3ah], 30.5.1.1.2." ::= { hh3cDot3EponMauType 7 } hh3cEponMauType1000BasePX20DONU OBJECT-IDENTITY STATUS current DESCRIPTION "EPON over 20K link, downlink (per 802.3 section 60), ONU side" REFERENCE "[802.3ah], 30.5.1.1.2." ::= { hh3cDot3EponMauType 8 } hh3cEponMauType1000BasePX20UOLT OBJECT-IDENTITY STATUS current DESCRIPTION "EPON over 20K link, uplink (per 802.3 section 60), OLT side" REFERENCE "[802.3ah], 30.5.1.1.2." ::= { hh3cDot3EponMauType 9 } hh3cEponMauType1000BasePX20UONU OBJECT-IDENTITY STATUS current DESCRIPTION "EPON over 20K link, uplink (per 802.3 section 60), ONU side" REFERENCE "[802.3ah], 30.5.1.1.2." ::= { hh3cDot3EponMauType 10 } -- Conformance Statements -- Conformance Groups hh3cDot3EponMauGroups OBJECT IDENTIFIER ::= { hh3cDot3EponMauConformance 1 } hh3cDot3EponMauGroupAll OBJECT-GROUP OBJECTS { hh3cDot3EponMauPCSCodingViolation } STATUS current DESCRIPTION "A collection of objects of dot3 MAU definition." ::= { hh3cDot3EponMauGroups 1 } hh3cDot3EponMauGroupFEC OBJECT-GROUP OBJECTS { hh3cDot3EponMauFecAbility, hh3cDot3EponMauFecMode, hh3cDot3EponMauFECCorrectedBlocks, hh3cDot3EponMauFECUncorrectableBlocks, hh3cDot3EponMauBufferHeadCodingViolation } STATUS current DESCRIPTION "A collection of objects of FEC group definition." ::= { hh3cDot3EponMauGroups 2 } -- Compliance hh3cDot3EponMauCompliances OBJECT IDENTIFIER ::= { hh3cDot3EponMauConformance 2 } hh3cDot3EponMauCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for MAU EPON interfaces." MODULE -- this module MANDATORY-GROUPS { hh3cDot3EponMauGroupAll } GROUP hh3cDot3EponMauGroupFEC DESCRIPTION "This group is mandatory for all EPON MAU devices Supporting FEC functionality as for Definitions and BER Statistics collection." ::= { hh3cDot3EponMauCompliances 1 } END