--=========================================================== -- Copyright (C) 2003 New H3C Tech. Co., Ltd. All rights reserved. -- Description: This MIB is excerpted from the draft-ietf-hubmib-efm-epon-mib-02 directly --- only changed the object name,added the hh3c as prefix. -- Reference: -- Version: V1.0 -- History: -- V1.0 created by liyue. -- Define MODULE-IDENTITY for hh3cEponDeviceMIB --================================================================= HH3C-EPON-DEVICE-MIB DEFINITIONS ::= BEGIN IMPORTS hh3cEpon FROM HH3C-OID-MIB MODULE-IDENTITY, mib-2, OBJECT-TYPE, Counter32, Unsigned32, Integer32, zeroDotZero FROM SNMPv2-SMI TruthValue, DateAndTime, RowStatus, MacAddress FROM SNMPv2-TC ifIndex FROM IF-MIB MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF SnmpAdminString FROM SNMP-FRAMEWORK-MIB; hh3cEponDeviceMIB MODULE-IDENTITY LAST-UPDATED "200409210000Z" -- September 21, 2004 ORGANIZATION "New H3C Tech. Co., Ltd." CONTACT-INFO "Platform Team New H3C Tech. Co., Ltd. Hai-Dian District Beijing P.R. China http://www.h3c.com Zip:100085 " DESCRIPTION "The objects in this MIB module are used to manage Ethernet Passive Optical Network (EPON) devices which are based on the Ethernet in the First Mile (EFM) PON as defined in IEEE Draft P802.3ah/D3.0 clause 60,64,65. This MIB is excerpted from the draft files directly,only changed the object name,added the hh3c as prefix. The following reference is used throughout this MIB module: [802.3ah] refers to: IEEE Draft P802.3ah/D3.3: 'Draft amendment to - Information technology - Telecommunications and information exchange between systems - Local and metropolitan area networks - Specific requirements - Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications - Media Access Control Parameters, Physical Layers and Management Parameters for subscriber access networks', 22 April 2004. Of particular interest are Clause 64(MPCP) 65(P2mP RS) and 60 (PON PMDs). Clause 30, 'Management', and Clause 45,'Management Data Input/Output (MDIO) Interface'. Copyright (C) The Internet Society (2004). This version of this MIB module is part of XXXX see the RFC itself for full legal notices." -- Editor's Note: Replace XXXX with the actual RFC number -- assigned by RFC Editor and remove this note REVISION "200409210000Z" -- September 21, 2004 DESCRIPTION "Initial version, published as RFC XXXX." ::= { hh3cEpon 4 } -- Editor's Note: Replace XXX with a real OID once it is -- assigned by IANA and remove this note. hh3cEponDeviceObjectMIB OBJECT IDENTIFIER ::= { hh3cEponDeviceMIB 1 } hh3cEponDeviceObjects OBJECT IDENTIFIER ::= { hh3cEponDeviceObjectMIB 1 } hh3cEponDeviceConformance OBJECT IDENTIFIER ::= { hh3cEponDeviceObjectMIB 2 } hh3cEponDeviceControlObjects OBJECT IDENTIFIER ::= { hh3cEponDeviceObjects 1 } hh3cEponDeviceStatObjects OBJECT IDENTIFIER ::= { hh3cEponDeviceObjects 2 } hh3cEponDeviceEventObjects OBJECT IDENTIFIER ::= { hh3cEponDeviceObjects 3 } hh3cEponDeviceControlTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cEponDeviceControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table for EPON device MIB modules." ::= { hh3cEponDeviceControlObjects 1 } hh3cEponDeviceControlEntry OBJECT-TYPE SYNTAX Hh3cEponDeviceControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the EPON device Control table." INDEX { ifIndex } ::= { hh3cEponDeviceControlTable 1 } Hh3cEponDeviceControlEntry ::= SEQUENCE { hh3cEponDeviceObjectReset INTEGER, hh3cEponDeviceObjectModes INTEGER, hh3cEponDeviceObjectFecEnabled INTEGER, hh3cEponDeviceObjectOamMode INTEGER, hh3cEponDeviceObjectDeviceReadyMode INTEGER, hh3cEponDeviceObjectPowerDown TruthValue, hh3cEponDeviceObjectNumberOfLLIDs Integer32, hh3cEponDeviceObjectReportThreshold Integer32, hh3cEponDeviceRemoteMACAddressLLIDControl INTEGER } hh3cEponDeviceObjectReset OBJECT-TYPE SYNTAX INTEGER { running(1), reset(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to reset the EPON device. The interface may be unavailable while the reset occurs and data may be lost. During reading operation it returns the state of the EPON device. running(1) indicates and operates normal operation, reset(2) indicates and operates reset mode. Writing can be done all the time." DEFVAL { 1 } ::= { hh3cEponDeviceControlEntry 1 } hh3cEponDeviceObjectModes OBJECT-TYPE SYNTAX INTEGER { olt(1), onu(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable defines the mode of the EPON device. When an olt(1) it is an Optical Line Terminal device (server) and when an onu(2) and Optical Network Unit device (client)" ::= { hh3cEponDeviceControlEntry 2 } hh3cEponDeviceObjectFecEnabled OBJECT-TYPE SYNTAX INTEGER { noFecEnabled (1), fecTxEnabled (2), fecRxEnabled (3), fecTxRxEnabled (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines and provides information whether the EPON device uses FEC as defined in the [802.3ah] clause 65.2 for EPON. When noFECEnabled(1) the device does not support FEC mode When fecTxEnabled(2) the device supports the FEC transmission mode. When fecRxEnabled(3) the device supports the FEC Receive mode. When fecTxRxEnabled(4) the device supports the FEC transmission and receive mode. Writing can be done all the time. This attribute is relevant for an OLT and an ONU." DEFVAL { 1 } ::= { hh3cEponDeviceControlEntry 4 } hh3cEponDeviceObjectOamMode OBJECT-TYPE SYNTAX INTEGER { noOam (1), oamServer (2), oamclient (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines and provides information on the Operation Administration and Maintenance (OAM) mode of an EPON device as defined by the [802.3ah] clause 57. When noOam(1) the device does not supports the OAM mode. When oamServer(2) the device supports the OAM mode as a server unit. When oamClient(3) the device supports the OAM mode as a client unit. Writing can be done during initialization, hh3cEponDeviceObjectDeviceReadyMode is in notReady(1) or inProcess(2). This attribute is relevant for an OLT and an ONU." DEFVAL { 1 } ::= { hh3cEponDeviceControlEntry 5 } hh3cEponDeviceObjectDeviceReadyMode OBJECT-TYPE SYNTAX INTEGER { notReady (1), inProcess (2), ready (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the mode of an EPON device and provides information on the mode in initialization - ready for registration as defined by the [802.3ah] clause 64. When notReady(1) the device is not ready for operation. When inProcess(2) the device is in initialization process. When ready(3) the device is ready for registration. Writing can be done all the time. This attribute is relevant for an OLT and an ONU." DEFVAL { 1 } ::= { hh3cEponDeviceControlEntry 6 } hh3cEponDeviceObjectPowerDown OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this variable to True(1) will cause Device to be entered into Power down mode where no registration is allowed and only receiving data from the link. Writing can be done all the time. This attribute is relevant for an OLT and an ONU." DEFVAL { false } ::= { hh3cEponDeviceControlEntry 7 } hh3cEponDeviceObjectNumberOfLLIDs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A read only variable which defines the number of registered LLIDs (as defined by the [802.3ah] clause 65) in a EPON network for an OLT and an ONU. Initialization value is 0. This attribute is relevant for an OLT and an ONU." ::= { hh3cEponDeviceControlEntry 8 } hh3cEponDeviceObjectReportThreshold OBJECT-TYPE SYNTAX Integer32 UNITS "TQ (16nsec)" MAX-ACCESS read-write STATUS current DESCRIPTION "A set of 8 integers, for each LLID, that defines the threshold reporting for each Queue in the REPORT message, as defined in [802.3ah] 64. First Queue set reporting will provide information on the queue occupancy of frames below this Threshold. The value returned shall be in Time quanta (TQ) which is 16nsec or 2 octets increments. Writing can be done all the time. This attribute is relevant for an OLT and an ONU." DEFVAL { 0 } ::= { hh3cEponDeviceControlEntry 9 } hh3cEponDeviceRemoteMACAddressLLIDControl OBJECT-TYPE SYNTAX INTEGER { none(1), resetLog(2), useDefaultReporting(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates and controls the resetting of the LLID MAC address log. Setting this object to none(1) has no action resetLog(2) empties the LLID MAC address log. All data is deleted. Setting it to useDefaultReporting(3) returns all entries priorities to their factory-default reporting. Reading this object always returns useDefaultReporting(3)." DEFVAL { 3 } ::= { hh3cEponDeviceControlEntry 10 } hh3cEponDeviceRemoteMACAddressLLIDTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cEponDeviceRemoteMACAddressLLIDEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of read-only value that identifies the source_address and LLIDs parameter of the remote devices in the network. This MacAddress value, as defined in [802.3ah], 30.3.5.1.5, is updated on reception of a valid frame with a unicast destination Field or (1) a destination Field equal to the reserved multicast address for MAC Control specified in [802.3ah] Annex 31A, (2) lengthOrType field value equal to the reserved Type for MAC Control as specified in [802.3ah] Annex 31A. (3)an MPCP subtype value equal to the subtype reserved for MPCP as specified in [802.3ah] Annex 31A, and an LLID as allocated by the OLT. The table is defined as Remote MAC address - LLID (RMadL) The table is relevant only for an OLT device, and is equivalent from a bridge emulation to the bridge port-MAC address table where the LLIDs are equivalent to virtual bridge ports." ::= { hh3cEponDeviceControlObjects 2 } hh3cEponDeviceRemoteMACAddressLLIDEntry OBJECT-TYPE SYNTAX Hh3cEponDeviceRemoteMACAddressLLIDEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A group of entries. Applications create and delete entries using hh3cEponDeviceRMadlEntryStatus. When adding objects to an LLID they are added in the persistent order of their index in this table." INDEX {ifIndex } ::= { hh3cEponDeviceRemoteMACAddressLLIDTable 1 } Hh3cEponDeviceRemoteMACAddressLLIDEntry ::= SEQUENCE { hh3cEponDeviceRemoteMACAddressLLIDName SnmpAdminString, hh3cEponDeviceRMadlLLID Unsigned32, hh3cEponDeviceRMadlLogID OBJECT IDENTIFIER, hh3cEponDeviceRMadlRemoteAddress MacAddress, hh3cEponDeviceRMadlType INTEGER, hh3cEponDeviceRMadlAction INTEGER, hh3cEponDeviceRMadlEntryStatus RowStatus } hh3cEponDeviceRemoteMACAddressLLIDName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (1..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "A locally-unique, administratively assigned name for a group of entries." ::= { hh3cEponDeviceRemoteMACAddressLLIDEntry 1 } hh3cEponDeviceRMadlLLID OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-create STATUS current DESCRIPTION "An arbitrary integer for the purpose of identifying the LLID. Writing can be done all the time." DEFVAL { 1 } ::= { hh3cEponDeviceRemoteMACAddressLLIDEntry 2 } hh3cEponDeviceRMadlLogID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-create STATUS current DESCRIPTION "The object identifier of a MIB module object to add to an entry, indicating the entry ID in the table. Writing can be done all the time." DEFVAL { zeroDotZero } ::= { hh3cEponDeviceRemoteMACAddressLLIDEntry 3 } hh3cEponDeviceRMadlRemoteAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The remote MAC address of the LLID. Writing can be done all the time." ::= { hh3cEponDeviceRemoteMACAddressLLIDEntry 4 } hh3cEponDeviceRMadlType OBJECT-TYPE SYNTAX INTEGER { notRegister (1), registered (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "A list of types for entries - LLIDs. Indicates and defines the state of registration. notRegister(1) marks a non registered LID, registered(2) marks a registered LLID. Writing can be done all the time." DEFVAL { 1 } ::= { hh3cEponDeviceRemoteMACAddressLLIDEntry 5 } hh3cEponDeviceRMadlAction OBJECT-TYPE SYNTAX INTEGER { none (1), register (2), deregister (3), reregister (4) } MAX-ACCESS read-create STATUS current DESCRIPTION "A list of actions for an entry - LLID. Indicates and defines the state of registration for the remote device. none(1) marks no action, register(2) marks to register an LLID, deregister(3) marks to deregister an LLID, reregister(4) marks reregistered LLID. Writing can be done all the time." DEFVAL { 1 } ::= { hh3cEponDeviceRemoteMACAddressLLIDEntry 6 } hh3cEponDeviceRMadlEntryStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The control that allows creation and deletion of entries. Once made active an entry MAY not be modified except to delete it." ::= { hh3cEponDeviceRemoteMACAddressLLIDEntry 7 } --Statistics tables hh3cEponDeviceStatTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cEponDeviceStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines the list of statistics counters of EPON devices. The attributes are relevant for an OLT and an ONU." ::= { hh3cEponDeviceStatObjects 1 } hh3cEponDeviceStatEntry OBJECT-TYPE SYNTAX Hh3cEponDeviceStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table entries for Table of statistics counters of EPON devices." INDEX { ifIndex } ::= { hh3cEponDeviceStatTable 1 } Hh3cEponDeviceStatEntry ::= SEQUENCE { hh3cEponDeviceStatTxFramesQueue0 Counter32, hh3cEponDeviceStatTxFramesQueue1 Counter32, hh3cEponDeviceStatTxFramesQueue2 Counter32, hh3cEponDeviceStatTxFramesQueue3 Counter32, hh3cEponDeviceStatTxFramesQueue4 Counter32, hh3cEponDeviceStatTxFramesQueue5 Counter32, hh3cEponDeviceStatTxFramesQueue6 Counter32, hh3cEponDeviceStatTxFramesQueue7 Counter32, hh3cEponDeviceStatRxFramesQueue0 Counter32, hh3cEponDeviceStatRxFramesQueue1 Counter32, hh3cEponDeviceStatRxFramesQueue2 Counter32, hh3cEponDeviceStatRxFramesQueue3 Counter32, hh3cEponDeviceStatRxFramesQueue4 Counter32, hh3cEponDeviceStatRxFramesQueue5 Counter32, hh3cEponDeviceStatRxFramesQueue6 Counter32, hh3cEponDeviceStatRxFramesQueue7 Counter32, hh3cEponDeviceStatDroppedFramesQueue0 Counter32, hh3cEponDeviceStatDroppedFramesQueue1 Counter32, hh3cEponDeviceStatDroppedFramesQueue2 Counter32, hh3cEponDeviceStatDroppedFramesQueue3 Counter32, hh3cEponDeviceStatDroppedFramesQueue4 Counter32, hh3cEponDeviceStatDroppedFramesQueue5 Counter32, hh3cEponDeviceStatDroppedFramesQueue6 Counter32, hh3cEponDeviceStatDroppedFramesQueue7 Counter32 } hh3cEponDeviceStatTxFramesQueue0 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-0- frames transmission occurs. Increment the counter by one for each frame transmitted which is an output of -Queue-0-. The -Queue-0- marking matched the REPORT MPCP message Queue-0 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { hh3cEponDeviceStatEntry 1 } hh3cEponDeviceStatTxFramesQueue1 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-1- frames transmission occurs. Increment the counter by one for each frame transmitted which is an output of -Queue-1-. The -Queue-1- marking matched the REPORT MPCP message Queue-1 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { hh3cEponDeviceStatEntry 2 } hh3cEponDeviceStatTxFramesQueue2 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-2- frames transmission occurs. Increment the counter by one for each frame transmitted which is an output of -Queue-2-. The -Queue-2- marking matched the REPORT MPCP message Queue-2 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { hh3cEponDeviceStatEntry 3 } hh3cEponDeviceStatTxFramesQueue3 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-3- frames transmission occurs. Increment the counter by one for each frame transmitted which is an output of -Queue-3-. The -Queue-3- marking matched the REPORT MPCP message Queue-3 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { hh3cEponDeviceStatEntry 4 } hh3cEponDeviceStatTxFramesQueue4 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-4- frames transmission occurs. Increment the counter by one for each frame transmitted which is an output of -Queue-4-. The -Queue-4- marking matched the REPORT MPCP message Queue-4 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { hh3cEponDeviceStatEntry 5 } hh3cEponDeviceStatTxFramesQueue5 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-5- frames transmission occurs. Increment the counter by one for each frame transmitted which is an output of -Queue-5-. The -Queue-5- marking matched the REPORT MPCP message Queue-5 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { hh3cEponDeviceStatEntry 6 } hh3cEponDeviceStatTxFramesQueue6 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-6- frames transmission occurs. Increment the counter by one for each frame transmitted which is an output of -Queue-6-. The -Queue-6- marking matched the REPORT MPCP message Queue-6 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { hh3cEponDeviceStatEntry 7 } hh3cEponDeviceStatTxFramesQueue7 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-7- frames transmission occurs. Increment the counter by one for each frame transmitted which is an output of -Queue-7-. The -Queue-7- marking matched the REPORT MPCP message Queue-7 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { hh3cEponDeviceStatEntry 8 } hh3cEponDeviceStatRxFramesQueue0 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-0- frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each frame received for each LLID, which is an output of -Queue-0-. The -Queue-0- marking matched the REPORT MPCP message Queue-0 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and an OLT." ::= { hh3cEponDeviceStatEntry 9 } hh3cEponDeviceStatRxFramesQueue1 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-1- frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each frame received for each LLID, which is an output of -Queue-1-. The -Queue-1- marking matched the REPORT MPCP message Queue-1 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and an OLT." ::= { hh3cEponDeviceStatEntry 10 } hh3cEponDeviceStatRxFramesQueue2 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-2- frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each frame received for each LLID, which is an output of -Queue-2-. The -Queue-2- marking matched the REPORT MPCP message Queue-2 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and an OLT." ::= { hh3cEponDeviceStatEntry 11 } hh3cEponDeviceStatRxFramesQueue3 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-3- frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each frame received for each LLID, which is an output of -Queue-3-. The -Queue-3- marking matched the REPORT MPCP message Queue-3 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and an OLT." ::= { hh3cEponDeviceStatEntry 12 } hh3cEponDeviceStatRxFramesQueue4 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-4- frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each frame received for each LLID, which is an output of -Queue-4-. The -Queue-4- marking matched the REPORT MPCP message Queue-4 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and an OLT." ::= { hh3cEponDeviceStatEntry 13 } hh3cEponDeviceStatRxFramesQueue5 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-5- frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each frame received for each LLID, which is an output of -Queue-5-. The -Queue-5- marking matched the REPORT MPCP message Queue-5 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and an OLT." ::= { hh3cEponDeviceStatEntry 14 } hh3cEponDeviceStatRxFramesQueue6 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-6- frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each frame received for each LLID, which is an output of -Queue-6-. The -Queue-6- marking matched the REPORT MPCP message Queue-6 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and an OLT." ::= { hh3cEponDeviceStatEntry 15 } hh3cEponDeviceStatRxFramesQueue7 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-7- frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each frame received for each LLID, which is an output of -Queue-7-. The -Queue-7- marking matched the REPORT MPCP message Queue-7 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and an OLT." ::= { hh3cEponDeviceStatEntry 16 } hh3cEponDeviceStatDroppedFramesQueue0 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-0- frames drops occurs. Increment the counter by one for each frame dropped from -Queue-0-. The -Queue-0- marking matched the REPORT MPCP message Queue-0 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { hh3cEponDeviceStatEntry 17 } hh3cEponDeviceStatDroppedFramesQueue1 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-1- frames drops occurs. Increment the counter by one for each frame dropped from -Queue-1-. The -Queue-1- marking matched the REPORT MPCP message Queue-1 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { hh3cEponDeviceStatEntry 18 } hh3cEponDeviceStatDroppedFramesQueue2 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-2- frames drops occurs. Increment the counter by one for each frame dropped from -Queue-2-. The -Queue-2- marking matched the REPORT MPCP message Queue-2 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { hh3cEponDeviceStatEntry 19 } hh3cEponDeviceStatDroppedFramesQueue3 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-3- frames drops occurs. Increment the counter by one for each frame dropped from -Queue-3-. The -Queue-3- marking matched the REPORT MPCP message Queue-3 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { hh3cEponDeviceStatEntry 20} hh3cEponDeviceStatDroppedFramesQueue4 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-4- frames drops occurs. Increment the counter by one for each frame dropped from -Queue-4-. The -Queue-4- marking matched the REPORT MPCP message Queue-4 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { hh3cEponDeviceStatEntry 21 } hh3cEponDeviceStatDroppedFramesQueue5 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-5- frames drops occurs. Increment the counter by one for each frame dropped from -Queue-5-. The -Queue-5- marking matched the REPORT MPCP message Queue-5 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { hh3cEponDeviceStatEntry 22 } hh3cEponDeviceStatDroppedFramesQueue6 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-6- frames drops occurs. Increment the counter by one for each frame dropped from -Queue-6-. The -Queue-6- marking matched the REPORT MPCP message Queue-6 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { hh3cEponDeviceStatEntry 23 } hh3cEponDeviceStatDroppedFramesQueue7 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-7- frames drops occurs. Increment the counter by one for each frame dropped from -Queue-7-. The -Queue-7- marking matched the REPORT MPCP message Queue-7 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { hh3cEponDeviceStatEntry 24 } --Editor's Note use reference to event MIB modules [RFC2981] and --docsis MIB modules [RFC2669] hh3cEponDeviceEventObjectTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cEponDeviceEventObjectEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines the Event Objects for EPON devices. The attributes are relevant for an OLT and an ONU." ::= { hh3cEponDeviceEventObjects 1 } hh3cEponDeviceEventObjectEntry OBJECT-TYPE SYNTAX Hh3cEponDeviceEventObjectEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table entries for Table of Event objects for EPON devices." INDEX { ifIndex } ::= { hh3cEponDeviceEventObjectTable 1 } Hh3cEponDeviceEventObjectEntry ::= SEQUENCE { hh3cEponDeviceSampleMinimum Integer32, hh3cEponDeviceDyingGaspAlarmState TruthValue, hh3cEponDeviceDyingGaspAlarmEnabled TruthValue, hh3cEponDeviceCriticalEventState TruthValue, hh3cEponDeviceCriticalEventEnabled TruthValue, hh3cEponDeviceLocalLinkFaultAlarmState TruthValue, hh3cEponDeviceLocalLinkFaultAlarmEnabled TruthValue, hh3cEponDeviceTemperatureEventIndicationState TruthValue, hh3cEponDeviceTemperatureEventIndicationEnabled TruthValue, hh3cEponDevicePowerVoltageEventIndicationState TruthValue, hh3cEponDevicePowerVoltageEventIndicationEnabled TruthValue, hh3cEponDeviceGlobalEventState TruthValue, hh3cEponDeviceGlobalEventEnabled TruthValue, hh3cEponDeviceErroredSymbolPeriodEventState TruthValue, hh3cEponDeviceErroredSymbolPeriodEventEnabled TruthValue, hh3cEponDeviceErroredFrameEventState TruthValue, hh3cEponDeviceErroredFrameEventEnabled TruthValue, hh3cEponDeviceErroredFramePeriodEventState TruthValue, hh3cEponDeviceErroredFramePeriodEventEnabled TruthValue, hh3cEponDeviceErroredFrameSecondsSummaryEventState TruthValue, hh3cEponDeviceErroredFrameSecondsSummaryEventEnabled TruthValue, hh3cEponDeviceOrganizationSpecificEventState TruthValue, hh3cEponDeviceOrganizationSpecificEventEnabled TruthValue, hh3cEponDeviceEventControl INTEGER } hh3cEponDeviceSampleMinimum OBJECT-TYPE SYNTAX Integer32 (1..2147483647) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "The minimum Frequency of events this system will accept. A system may use the larger values of this minimum to lessen the impact of constant sampling. For larger sampling intervals the system samples less often and suffers less overhead. Unless explicitly resource limited, a system's value for this object SHOULD be 1, allowing as small as a 1 second interval for ongoing trigger sampling. Writing of the value can be done all the time." DEFVAL { 1 } ::= { hh3cEponDeviceEventObjectEntry 1 } hh3cEponDeviceDyingGaspAlarmState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Dying Gasp indication of the OAM alarm indications as described in the [802.3ah] clause 57. When true the device has a dying gasp alarm asserted. When false the dying gasp alarm is reset " ::= { hh3cEponDeviceEventObjectEntry 2 } hh3cEponDeviceDyingGaspAlarmEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow DyingGaspAlarm event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { hh3cEponDeviceEventObjectEntry 3 } hh3cEponDeviceCriticalEventState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Critical Event indication of the OAM alarm indications as described in the [802.3ah] clause 57. When true the device has a Critical Event asserted. When false the Critical Event is reset." ::= { hh3cEponDeviceEventObjectEntry 4 } hh3cEponDeviceCriticalEventEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow CriticalEvent event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { hh3cEponDeviceEventObjectEntry 5 } hh3cEponDeviceLocalLinkFaultAlarmState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Local Link Fault indication of the OAM alarm indications as described in the [802.3ah] clause 57. When true the device has a Local Link Fault alarm asserted. When false the Local Link Fault alarm is reset." ::= { hh3cEponDeviceEventObjectEntry 6 } hh3cEponDeviceLocalLinkFaultAlarmEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow LocalLinkFaultAlarm event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { hh3cEponDeviceEventObjectEntry 7 } hh3cEponDeviceTemperatureEventIndicationState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Temperature Event indication of an EPON device. When condition of box temperature is above the threshold defined the alarm is asserted. When the condition is below that threshold the alarm is de-asserted. When true the device has a Temperature Event Indication asserted. When false the Temperature Event Indication is reset." ::= { hh3cEponDeviceEventObjectEntry 8 } hh3cEponDeviceTemperatureEventIndicationEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow TemperatureEventIndication event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { hh3cEponDeviceEventObjectEntry 9 } hh3cEponDevicePowerVoltageEventIndicationState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Power/Voltage Event Indication of an EPON device. When condition of box Power/voltage is above the threshold defined the alarm is asserted. When the condition is below that threshold the alarm is de-asserted. When true the device has a Power/Voltage Event Indication asserted. When false the Power/Voltage Event Indication is reset. " ::= { hh3cEponDeviceEventObjectEntry 10 } hh3cEponDevicePowerVoltageEventIndicationEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow PowerVoltageEventIndication event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { hh3cEponDeviceEventObjectEntry 11 } hh3cEponDeviceGlobalEventState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Global Event indication of an EPON device. When the indication of the event input occurs the event is asserted. When the input is removed that event is de-asserted. When true the device has a Global Event asserted. When false the Global Event Indication is reset." ::= { hh3cEponDeviceEventObjectEntry 12 } hh3cEponDeviceGlobalEventEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow GlobalEvent event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { hh3cEponDeviceEventObjectEntry 13 } hh3cEponDeviceErroredSymbolPeriodEventState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Errored Symbol Period Event indication of the OAM alarm TLV indications as described in the [802.3ah] clause 57.5.3. When true the device has an Errored Symbol Period Event asserted. When false the Errored Symbol Period Event is reset." ::= { hh3cEponDeviceEventObjectEntry 14 } hh3cEponDeviceErroredSymbolPeriodEventEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow ErroredSymbolPeriodEvent event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { hh3cEponDeviceEventObjectEntry 15 } hh3cEponDeviceErroredFrameEventState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Errored Frame Event indication of the OAM alarm TLV indications as described in the [802.3ah] clause 57.5.3. When true the device has an Errored Frame Event asserted. When false the Errored Frame Event is reset." ::= { hh3cEponDeviceEventObjectEntry 16 } hh3cEponDeviceErroredFrameEventEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow ErroredFrameEvent event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { hh3cEponDeviceEventObjectEntry 17 } hh3cEponDeviceErroredFramePeriodEventState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Errored Frame Period Event indication of the OAM alarm TLV indications as described in the [802.3ah] clause 57.5.3. When true the device has an Errored Frame Period Event asserted. When false the Errored Frame Period Event is reset." ::= { hh3cEponDeviceEventObjectEntry 18 } hh3cEponDeviceErroredFramePeriodEventEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow ErroredFramePeriodEvent event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { hh3cEponDeviceEventObjectEntry 19 } hh3cEponDeviceErroredFrameSecondsSummaryEventState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Errored Frame Seconds Summary Event indication of the OAM alarm TLV indications as described in the [802.3ah] clause 57.5.3. When true the device has an Errored Frame Seconds Summary Event asserted. When false the Errored Frame Seconds Summary Event is reset." ::= { hh3cEponDeviceEventObjectEntry 20 } hh3cEponDeviceErroredFrameSecondsSummaryEventEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow ErroredFrameSecondsSummaryEvent event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { hh3cEponDeviceEventObjectEntry 21 } hh3cEponDeviceOrganizationSpecificEventState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Organization Specific Event indication of the OAM alarm TLV indications as described in the [802.3ah] clause 57.5.3. When true the device has an Organization Specific Event asserted. When false the Organization Specific Event is reset." ::= { hh3cEponDeviceEventObjectEntry 22 } hh3cEponDeviceOrganizationSpecificEventEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow OrganizationSpecificEvent event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { hh3cEponDeviceEventObjectEntry 23 } hh3cEponDeviceEventControl OBJECT-TYPE SYNTAX INTEGER { none(1), resetLog(2), useDefaultReporting(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates and controls the resetting of the Event log. Setting this object to none(1) has no action resetLog(2) empties the event log. All data is deleted. Setting it to useDefaultReporting(3) returns all event priorities to their factory-default reporting. Reading this object always returns useDefaultReporting(3)." DEFVAL { 3 } ::= { hh3cEponDeviceEventObjectEntry 24 } -- Events Log Table hh3cEponDeviceEventsLogTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cEponDeviceEventsLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of objects provides a log of notification based on the event as pointed to by entries in those tables. The intent is a MAC level event log (set of events to when they happened). This attribute is relevant for an OLT and an ONU." ::= { hh3cEponDeviceEventObjects 2 } hh3cEponDeviceEventsLogEntry OBJECT-TYPE SYNTAX Hh3cEponDeviceEventsLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A group of Events. Applications create and delete entries using hh3cEponDeviceEventsEntryStatus. When adding objects to a notification they are added in the lexical order of their index in this table." INDEX { hh3cEponDeviceEventsLogName, hh3cEponDeviceEventsLogIndex } ::= { hh3cEponDeviceEventsLogTable 1 } Hh3cEponDeviceEventsLogEntry ::= SEQUENCE { hh3cEponDeviceEventsLogName SnmpAdminString, hh3cEponDeviceEventsLogIndex Unsigned32, hh3cEponDeviceEventsLogID OBJECT IDENTIFIER, hh3cEponDeviceEventsLogFirstTime DateAndTime, hh3cEponDeviceEventsLogLastTime DateAndTime, hh3cEponDeviceEventsLogCounts Counter32, hh3cEponDeviceEventsLogType INTEGER, hh3cEponDeviceEventsLogEntryStatus RowStatus } hh3cEponDeviceEventsLogName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (1..32)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A locally-unique, administratively assigned name for a group of Events." ::= { hh3cEponDeviceEventsLogEntry 1 } hh3cEponDeviceEventsLogIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer for the purpose of identifying individual Events within a hh3cEponDeviceEventsLogName group. Events within a group are placed in the notification in the numerical order of this index." ::= { hh3cEponDeviceEventsLogEntry 2 } hh3cEponDeviceEventsLogID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-create STATUS current DESCRIPTION "The object identifier of a MIB module object to add to a Notification that results from the event. Writing can be done all the time." DEFVAL { zeroDotZero } ::= { hh3cEponDeviceEventsLogEntry 3 } hh3cEponDeviceEventsLogFirstTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The time that an entry was created." ::= { hh3cEponDeviceEventsLogEntry 4 } hh3cEponDeviceEventsLogLastTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "If multiple events are reported via the same entry, the time that the last event for this entry occurred, otherwise this should have the same value as hh3cEponDeviceEventsLogFirstTime." ::= { hh3cEponDeviceEventsLogEntry 5 } hh3cEponDeviceEventsLogCounts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of consecutive event instances reported by this entry. This starts at 1 with the creation of this row and increments by 1 for each subsequent duplicate event." ::= { hh3cEponDeviceEventsLogEntry 6 } hh3cEponDeviceEventsLogType OBJECT-TYPE SYNTAX INTEGER { hh3cEponDeviceDyingGaspAlarmState (1), hh3cEponDeviceCriticalEventState (2), hh3cEponDeviceLocalLinkFaultAlarmState (3), hh3cEponDeviceTemperatureEventIndicationState (4), hh3cEponDevicePowerVoltageEventIndicationState (5), hh3cEponDeviceGlobalEventState (6), hh3cEponDeviceErroredSymbolPeriodEventState (7), hh3cEponDeviceErroredFrameEventState (8), hh3cEponDeviceErroredFramePeriodEventState (9), hh3cEponDeviceErroredFrameSecondsSummaryEventState (10), hh3cEponDeviceOrganizationSpecificEventState (11) } MAX-ACCESS read-only STATUS current DESCRIPTION "A list of types for Events. Events are ordered according to their significance where 1 is the highest severity. hh3cEponDeviceDyingGaspAlarmState(1) indicates a Dying Gasp Alarm State, hh3cEponDeviceCriticalEventState(2) indicates a Critical Event State, hh3cEponDeviceLocalLinkFaultAlarmState(3) indicates a Local Link Fault Alarm State, hh3cEponDeviceTemperatureEventIndicationState(4) indicates a Temperature Event Indication State, hh3cEponDevicePowerVoltageEventIndicationState(5) indicates a Power Voltage Event Indication State, hh3cEponDeviceGlobalEventState(6) indicates a Global Event State, hh3cEponDeviceErroredSymbolPeriodEventState(7) indicates an Errored Symbol Period Event State, hh3cEponDeviceErroredFrameEventState(8) indicates an Errored Frame Event State, hh3cEponDeviceErroredFramePeriodEventState(9) indicates an Errored Frame Period Event State, hh3cEponDeviceErroredFrameSecondsSummaryEventState(10) indicates an Errored Frame Seconds Summary Event State, hh3cEponDeviceOrganizationSpecificEventState(11) indicates an Organization Specific Event State. " ::= { hh3cEponDeviceEventsLogEntry 7 } hh3cEponDeviceEventsLogEntryStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The control that allows creation and deletion of entries. Once made active an entry MAY not be modified except to delete it." ::= { hh3cEponDeviceEventsLogEntry 8 } -- Conformance Statements -- Conformance Groups hh3cEponDeviceGroups OBJECT IDENTIFIER ::= { hh3cEponDeviceConformance 1 } hh3cEponDeviceGroupControl OBJECT-GROUP OBJECTS { hh3cEponDeviceObjectReset, hh3cEponDeviceObjectModes, hh3cEponDeviceObjectFecEnabled, hh3cEponDeviceObjectOamMode, hh3cEponDeviceObjectDeviceReadyMode, hh3cEponDeviceObjectPowerDown, hh3cEponDeviceObjectNumberOfLLIDs, hh3cEponDeviceObjectReportThreshold, hh3cEponDeviceRemoteMACAddressLLIDControl } STATUS current DESCRIPTION "A collection of objects of hh3cEponDevice control definition." ::= { hh3cEponDeviceGroups 1 } hh3cEponDeviceGroupRMadLTable OBJECT-GROUP OBJECTS { hh3cEponDeviceRMadlLLID, hh3cEponDeviceRMadlLogID, hh3cEponDeviceRMadlRemoteAddress, hh3cEponDeviceRMadlType, hh3cEponDeviceRMadlAction, hh3cEponDeviceRMadlEntryStatus } STATUS current DESCRIPTION "A collection of objects of hh3cEponDevice remote Mac address to LLID table." ::= { hh3cEponDeviceGroups 2 } hh3cEponDeviceGroupStat OBJECT-GROUP OBJECTS { hh3cEponDeviceStatTxFramesQueue0, hh3cEponDeviceStatTxFramesQueue1, hh3cEponDeviceStatTxFramesQueue2, hh3cEponDeviceStatTxFramesQueue3, hh3cEponDeviceStatTxFramesQueue4, hh3cEponDeviceStatTxFramesQueue5, hh3cEponDeviceStatTxFramesQueue6, hh3cEponDeviceStatTxFramesQueue7, hh3cEponDeviceStatRxFramesQueue0, hh3cEponDeviceStatRxFramesQueue1, hh3cEponDeviceStatRxFramesQueue2, hh3cEponDeviceStatRxFramesQueue3, hh3cEponDeviceStatRxFramesQueue4, hh3cEponDeviceStatRxFramesQueue5, hh3cEponDeviceStatRxFramesQueue6, hh3cEponDeviceStatRxFramesQueue7, hh3cEponDeviceStatDroppedFramesQueue0, hh3cEponDeviceStatDroppedFramesQueue1, hh3cEponDeviceStatDroppedFramesQueue2, hh3cEponDeviceStatDroppedFramesQueue3, hh3cEponDeviceStatDroppedFramesQueue4, hh3cEponDeviceStatDroppedFramesQueue5, hh3cEponDeviceStatDroppedFramesQueue6, hh3cEponDeviceStatDroppedFramesQueue7 } STATUS current DESCRIPTION "A collection of objects of EPON device Statistics" ::= { hh3cEponDeviceGroups 3 } hh3cEponDeviceGroupEvent OBJECT-GROUP OBJECTS { hh3cEponDeviceSampleMinimum, hh3cEponDeviceDyingGaspAlarmState, hh3cEponDeviceDyingGaspAlarmEnabled, hh3cEponDeviceCriticalEventState, hh3cEponDeviceCriticalEventEnabled, hh3cEponDeviceLocalLinkFaultAlarmState, hh3cEponDeviceLocalLinkFaultAlarmEnabled, hh3cEponDeviceTemperatureEventIndicationState, hh3cEponDeviceTemperatureEventIndicationEnabled, hh3cEponDevicePowerVoltageEventIndicationState, hh3cEponDevicePowerVoltageEventIndicationEnabled, hh3cEponDeviceGlobalEventState, hh3cEponDeviceGlobalEventEnabled, hh3cEponDeviceErroredSymbolPeriodEventState, hh3cEponDeviceErroredSymbolPeriodEventEnabled, hh3cEponDeviceErroredFrameEventState, hh3cEponDeviceErroredFrameEventEnabled, hh3cEponDeviceErroredFramePeriodEventState , hh3cEponDeviceErroredFramePeriodEventEnabled , hh3cEponDeviceErroredFrameSecondsSummaryEventState , hh3cEponDeviceErroredFrameSecondsSummaryEventEnabled, hh3cEponDeviceOrganizationSpecificEventState , hh3cEponDeviceOrganizationSpecificEventEnabled, hh3cEponDeviceEventControl } STATUS current DESCRIPTION "A collection of objects for EPON device Events" ::= { hh3cEponDeviceGroups 4 } hh3cEponDeviceGroupEventLog OBJECT-GROUP OBJECTS { hh3cEponDeviceEventsLogID, hh3cEponDeviceEventsLogFirstTime, hh3cEponDeviceEventsLogLastTime, hh3cEponDeviceEventsLogCounts, hh3cEponDeviceEventsLogType, hh3cEponDeviceEventsLogEntryStatus } STATUS current DESCRIPTION "A collection of objects for EPON device Events log" ::= { hh3cEponDeviceGroups 5 } -- Compliance hh3cEponDeviceCompliances OBJECT IDENTIFIER ::= { hh3cEponDeviceConformance 2 } hh3cEponDeviceCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for EPON Devices." MODULE -- this module MANDATORY-GROUPS { hh3cEponDeviceGroupControl } GROUP hh3cEponDeviceGroupRMadLTable DESCRIPTION " This group is mandatory for all OLT EPON devices supporting LLID-MAC address table." GROUP hh3cEponDeviceGroupStat DESCRIPTION "This group is mandatory for all EPON devices supporting interfaces for Statistics collection." GROUP hh3cEponDeviceGroupEvent DESCRIPTION "This group is mandatory for all EPON devices supporting interfaces for event collection." GROUP hh3cEponDeviceGroupEventLog DESCRIPTION "This group is mandatory for all EPON devices supporting interfaces for event log collection." ::= { hh3cEponDeviceCompliances 1 } END