-- ============================================================================ -- Copyright (c) 2004-2015 New H3C Tech. Co., Ltd. All rights reserved. -- -- Description: Port Extender (PEX) information MIB -- Reference: -- Version: V1.2 -- History: -- V1.0 2012-11-12 Initial version by Yang Fan -- V1.1 2014-03-31 Changed MIB node name to PEX by zushuzhi -- V1.2 2015-10-15 Added hh3cPexDeviceInfoTable and hh3cPexTopoTable -- by zushuzhi -- ============================================================================ HH3C-PEX-MIB DEFINITIONS ::= BEGIN IMPORTS hh3cCommon FROM HH3C-OID-MIB entPhysicalIndex, entPhysicalDescr FROM ENTITY-MIB Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI RowStatus, DisplayString FROM SNMPv2-TC; hh3cPex MODULE-IDENTITY LAST-UPDATED "201510151129Z" -- 15th October, 2015 at 11:29 GMT ORGANIZATION "New H3C Technologies Co., Ltd." CONTACT-INFO "Platform Team New H3C Technologies Co., Ltd. Haidian District Beijing P.R. China Http://www.h3c.com Zip:100085" DESCRIPTION "This MIB is used to manage Port Extender (PEX) information. This MIB is applicable to products that support PEX." REVISION "201510151129Z" DESCRIPTION "Added hh3cPexDeviceInfoTable and hh3cPexTopoTable." REVISION "201211121129Z" DESCRIPTION "Initial version of this MIB module." ::= { hh3cCommon 129 } -- PEX Specification Information hh3cPexSpecInfo OBJECT IDENTIFIER ::= { hh3cPex 1 } hh3cPexPortMinId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Lowest PEX port ID that can be used to uniquely identify a PEX port." ::= { hh3cPexSpecInfo 1 } hh3cPexPortMaxId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Highest PEX port ID that can be used to uniquely identify a PEX port." ::= { hh3cPexSpecInfo 2 } hh3cPexMinAssociateId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Lowest ID that can be assigned to a port extender (PEX)." ::= { hh3cPexSpecInfo 3 } hh3cPexMaxAssociateId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Highest ID that can be assigned to a PEX." ::= { hh3cPexSpecInfo 4 } hh3cPexMaxPortPerPexPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum number of ports that can be bound to a PEX port." ::= { hh3cPexSpecInfo 5 } -- PEX Information hh3cPexTable OBJECT IDENTIFIER ::= { hh3cPex 2 } hh3cPexPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cPexPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects used to configure the PEX ports." ::= { hh3cPexTable 1 } hh3cPexPortEntry OBJECT-TYPE SYNTAX Hh3cPexPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a PEX." INDEX { hh3cPexPortId } ::= { hh3cPexPortTable 1 } Hh3cPexPortEntry ::= SEQUENCE { hh3cPexPortId Integer32, hh3cPexPortAssociateId Integer32, hh3cPexPortEntPhysicalIndex Integer32, hh3cPexPortDescr DisplayString, hh3cPexPortStatus INTEGER, hh3cPexPortRowStatus RowStatus } hh3cPexPortId OBJECT-TYPE SYNTAX Integer32(1..2147483647) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "ID that can be used to uniquely identify a PEX port. The value range is hh3cPexPortMinId to hh3cPexPortMaxId." ::= { hh3cPexPortEntry 1 } hh3cPexPortAssociateId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "ID assigned to a PEX. The value range is hh3cPexMinAssociateId to hh3cPexMaxAssociateId. The value is 0xffff if the PEX is not assigned an ID. For a successful configuration, the ID should not be used by any other PEX." DEFVAL { 65535 } ::= { hh3cPexPortEntry 2 } hh3cPexPortEntPhysicalIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Entity index of a PEX in the IRF. A value of zero indicates that the PEX is not online." DEFVAL { 0 } ::= { hh3cPexPortEntry 3 } hh3cPexPortDescr OBJECT-TYPE SYNTAX DisplayString(SIZE(0..79)) MAX-ACCESS read-create STATUS current DESCRIPTION "Description for the PEX port. The default value is 'pex-port XXXX', where 'XXXX' is hh3cPexPortId. Writing a zero-length string to this object resets the value to the default." ::= { hh3cPexPortEntry 4 } hh3cPexPortStatus OBJECT-TYPE SYNTAX INTEGER { offline(1), loading(2), online(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the PEX. offline: The PEX is absent or its configuration is incomplete. loading: The PEX is loading software. online: The PEX is operating correctly." DEFVAL { offline } ::= { hh3cPexPortEntry 5 } hh3cPexPortRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The control that allows creation and deletion of entries. Values include createAndGo, active, and destroy. If the row to be created or modified already exists, an error message is returned. If the row to be deleted does not exist, a success message is returned." ::= { hh3cPexPortEntry 6 } -- PEX PhyPort Information hh3cPexPhyPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cPexPhyPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects used to manage physical ports that can be bound or are already bound to a PEX port." ::= { hh3cPexTable 2 } hh3cPexPhyPortEntry OBJECT-TYPE SYNTAX Hh3cPexPhyPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a physical port that can be bound to or has been bound to a PEX port." INDEX { entPhysicalIndex } ::= { hh3cPexPhyPortTable 1 } Hh3cPexPhyPortEntry ::= SEQUENCE { hh3cPexPhyPortStatus INTEGER, hh3cPexPhyPortBelongToPexPort Integer32, hh3cPexPhyPortNeighborEntIndex Integer32 } hh3cPexPhyPortStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), down(2), blocked(3), forwarding(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the physical port that is bound to a PEX port. The following are status values: unknown: The physical port is not bound to any PEX port. down: The physical port is link down. blocked: The physical port is blocked and cannot forward traffic. forwarding: The physical port can forwarding traffic." DEFVAL { unknown } ::= { hh3cPexPhyPortEntry 1 } hh3cPexPhyPortBelongToPexPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "ID of the PEX port to which the physical port belongs. The value range is hh3cPexPortMinId to hh3cPexPortMaxId. A value of zero indicates that the port doesn't belong to any PEX port." DEFVAL { 0 } ::= { hh3cPexPhyPortEntry 2 } hh3cPexPhyPortNeighborEntIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Entity index of a physical port that connects the PEX to the parent device. This value is identical to entPhysicalIndex in ENTITY-MIB. A value of zero indicates that the physical port is not bound to any PEX port or is not up." ::= { hh3cPexPhyPortEntry 3 } -- PEX Topology Information hh3cPexDeviceInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cPexDeviceInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains online PEXs in the IRF system." ::= { hh3cPexTable 3 } hh3cPexDeviceInfoEntry OBJECT-TYPE SYNTAX Hh3cPexDeviceInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a PEX in the IRF system. The index is the PEX entity index." INDEX { entPhysicalIndex } ::= { hh3cPexDeviceInfoTable 1 } Hh3cPexDeviceInfoEntry ::= SEQUENCE { hh3cPexDeviceStatus INTEGER, hh3cPexDeviceAssociateId Integer32 } hh3cPexDeviceStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), faulty(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the PEX. normal: The PEX is operating correctly. faulty: The PEX is faulty." ::= { hh3cPexDeviceInfoEntry 1 } hh3cPexDeviceAssociateId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "ID assigned to the PEX." ::= { hh3cPexDeviceInfoEntry 2 } hh3cPexTopoTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cPexTopoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains information about the PEX physical ports and neighbor ports on PEXs." ::= { hh3cPexTable 4 } hh3cPexTopoEntry OBJECT-TYPE SYNTAX Hh3cPexTopoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a PEX link." INDEX { entPhysicalIndex } ::= { hh3cPexTopoTable 1 } Hh3cPexTopoEntry ::= SEQUENCE { hh3cPexNeighborEntIndex Integer32 } hh3cPexNeighborEntIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Entity index of a PEX in the IRF system." ::= { hh3cPexTopoEntry 1 } -- PEX Traps hh3cPexTraps OBJECT IDENTIFIER ::= { hh3cPex 3 } hh3cPexTrapPrefix OBJECT IDENTIFIER ::= { hh3cPexTraps 0 } hh3cPexPortOnline NOTIFICATION-TYPE OBJECTS { hh3cPexPortId, hh3cPexPortDescr } STATUS current DESCRIPTION "An hh3cPexPortOnline trap is sent when the PEX transitions to online state." ::= { hh3cPexTrapPrefix 1 } hh3cPexPortOffline NOTIFICATION-TYPE OBJECTS { hh3cPexPortId, hh3cPexPortDescr } STATUS current DESCRIPTION "An hh3cPexPortOnline trap is sent when the PEX transitions to offline state." ::= { hh3cPexTrapPrefix 2 } hh3cPexPhyPortForwarding NOTIFICATION-TYPE OBJECTS { hh3cPexEntPhysicalIndexBind, entPhysicalDescr } STATUS current DESCRIPTION "An hh3cPexPhyPortForwarding trap is sent when the PEX physical port transitions to forwarding state." ::= { hh3cPexTrapPrefix 3 } hh3cPexPhyPortBlocked NOTIFICATION-TYPE OBJECTS { hh3cPexEntPhysicalIndexBind, entPhysicalDescr } STATUS current DESCRIPTION "An hh3cPexPhyPortBlocked trap is sent when the PEX physical port transitions from forwarding state to blocked state." ::= { hh3cPexTrapPrefix 4 } hh3cPexTrapObjects OBJECT IDENTIFIER ::= { hh3cPex 4 } hh3cPexEntPhysicalIndexBind OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This index is identical to entPhysicalIndex in ENTITY-MIB." ::= { hh3cPexTrapObjects 1 } END