--Last Mile Gear CTM Master MIB CTMMIB DEFINITIONS ::= BEGIN IMPORTS enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; lastmilegear OBJECT IDENTIFIER ::= { enterprises 25868 } mibObjects OBJECT IDENTIFIER ::= { lastmilegear 1 } version OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Version of Web GUI - Version of Web GUI Interface currently running on CTM" ::= { mibObjects 1 } site OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Site Name - Site name as stored on CTM" ::= { mibObjects 2 } lastIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Last IP Address Login - Last IP address captured at Login Attempt" ::= { mibObjects 3 } lastTime OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Last Time Login - Last time of Login attempt" ::= { mibObjects 4 } nSats OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number Satellites in View - Number of Satellites in view of GPS Receiver Antenna being used for timing calculations" ::= { mibObjects 5 } pwrP OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Primary Power - Master ?1? = Power OK, ?0? = Power Off or Low" ::= { mibObjects 6 } pwrS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Secondary Power - Master ?1? = Power OK, ?0? = Power Off or Low" ::= { mibObjects 7 } cbTrip OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Master Circuit Breaker Trip Bit Code - Master Breaker Tripped Code: 1=Port 1, 2=Port2, 4=Port 3, 8=Port4, 16=Port5, 32=Port6, 64=Port7, 128=Port8 Example: Code 5 means Port 3 and Port 1 Tripped" ::= { mibObjects 8 } tempC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Temperature" ::= { mibObjects 9 } voltsM1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Primary Power In Voltage - In Tenths of a Volt" ::= { mibObjects 10 } voltsM2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Secondary Power In Voltage - In Tenths of a Volt" ::= { mibObjects 11 } portOnM OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Master Ports ON Enabled Status - Master ?1? =Sync Enabled, ?0? = Sync Off listed in order ?Port1?, ?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?, ?Port7?, ?Port8?" ::= { mibObjects 12 } portSyncM OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Master Ports Sync Enabled Status - Master ?1? =Sync Enabled, ?0? = Sync Off listed in order ?Port1?, ?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?, ?Port7?, ?Port8?" ::= { mibObjects 13 } portPwrM1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Power Port 1 - (in tenths of a Watt) delivered on Port 1" ::= { mibObjects 14 } portPwrM2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Power Port 2 - (in tenths of a Watt) delivered on Port 2" ::= { mibObjects 15 } portPwrM3 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Power Port 3 - (in tenths of a Watt) delivered on Port 3" ::= { mibObjects 16 } portPwrM4 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Power Port 4 - (in tenths of a Watt) delivered on Port 4" ::= { mibObjects 17 } portPwrM5 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Power Port 5 - (in tenths of a Watt) delivered on Port 5" ::= { mibObjects 18 } portPwrM6 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Power Port 6 - (in tenths of a Watt) delivered on Port 6" ::= { mibObjects 19 } portPwrM7 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Power Port 7 - (in tenths of a Watt) delivered on Port 7" ::= { mibObjects 20 } portPwrM8 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Power Port 8 - (in tenths of a Watt) delivered on Port 8" ::= { mibObjects 21 } modeReqM OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Master CTM2 Port Type Setting - Master ?00?=Type A (Canopy) ?10?=Type B (OFDM), ?01? = Type C (POE 802.3at), ?11? (POE 802.3at 4 Pair), ?100?=(POE 24V mode, CTM2 C Only) listed in order ?Port1?, ?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?, ?Port7?, ?Port8?" ::= { mibObjects 39 } trpCntGM1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Auto Restart Count Port 1 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 1" ::= { mibObjects 45 } trpCntGM2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Auto Restart Count Port 2 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 2" ::= { mibObjects 46 } trpCntGM3 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Auto Restart Count Port 3 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 3" ::= { mibObjects 47 } trpCntGM4 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Auto Restart Count Port 4 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 4" ::= { mibObjects 48 } trpCntGM5 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Auto Restart Count Port 5 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 5" ::= { mibObjects 49 } trpCntGM6 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Auto Restart Count Port 6 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 6" ::= { mibObjects 50 } trpCntGM7 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Auto Restart Count Port 7 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 7" ::= { mibObjects 51 } trpCntGM8 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Auto Restart Count Port 8 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 8" ::= { mibObjects 52 } trpCntBM1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Ckt Breaker Auto Restart Fail Count Port 1 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 1" ::= { mibObjects 53 } trpCntBM2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Ckt Breaker Auto Restart Fail Count Port 2 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 2" ::= { mibObjects 54 } trpCntBM3 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Ckt Breaker Auto Restart Fail Count Port 3 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 3" ::= { mibObjects 55 } trpCntBM4 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Ckt Breaker Auto Restart Fail Count Port 4 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 4" ::= { mibObjects 56 } trpCntBM5 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Ckt Breaker Auto Restart Fail Count Port 5 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 5" ::= { mibObjects 57 } trpCntBM6 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Ckt Breaker Auto Restart Fail Count Port 6 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 6" ::= { mibObjects 58 } trpCntBM7 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Ckt Breaker Auto Restart Fail Count Port 7 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 7" ::= { mibObjects 59 } trpCntBM8 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Master Ckt Breaker Auto Restart Fail Count Port 8 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 8" ::= { mibObjects 60 } lostEthernetConnection TRAP-TYPE ENTERPRISE mibObjects DESCRIPTION "Lost Ethernet Connection" ::= 0 masterPrimayPowerLost TRAP-TYPE ENTERPRISE mibObjects DESCRIPTION "Master Primary Power Lost" ::= 1 masterSecondaryPowerLost TRAP-TYPE ENTERPRISE mibObjects DESCRIPTION "Master Secondary Power Lost" ::= 2 gpsSignalLost TRAP-TYPE ENTERPRISE mibObjects DESCRIPTION "GPS Signal Lost" ::= 3 masterTempatureError TRAP-TYPE ENTERPRISE mibObjects DESCRIPTION "Master Temperature Error" ::= 4 masterCircuitBreakerTripCode TRAP-TYPE ENTERPRISE mibObjects DESCRIPTION "Master Circuit Breaker Trip Code - Master Breaker Tripped Code: 1=Port 1, 2=Port2, 4=Port 3, 8=Port4, 16=Port5, 32=Port6, 64=Port7, 128=Port8 Example: Code 5 means Port 3 and Port 1 Tripped" ::= 5 loginFailedAttempt TRAP-TYPE ENTERPRISE mibObjects DESCRIPTION "Login Failed Attempt" ::= 6 settingsChanged TRAP-TYPE ENTERPRISE mibObjects DESCRIPTION "CTM Settings Changed" ::= 7 masterPrimaryPowerOK TRAP-TYPE ENTERPRISE mibObjects DESCRIPTION "Master Primary Power OK" ::= 10 masterSecondaryPowerOK TRAP-TYPE ENTERPRISE mibObjects DESCRIPTION "Master Secondary Power OK" ::= 20 gpsSignalOK TRAP-TYPE ENTERPRISE mibObjects DESCRIPTION "GPS Signal OK" ::= 30 tempatureOK TRAP-TYPE ENTERPRISE mibObjects DESCRIPTION "Temperature OK" ::= 40 circuitBreakersOK TRAP-TYPE ENTERPRISE mibObjects DESCRIPTION "Circuit Breakers OK" ::= 50 masterAutoRestartCBCompletedOK TRAP-TYPE ENTERPRISE mibObjects DESCRIPTION "Master Auto Restart CB Completed OK" ::= 52 loginOK TRAP-TYPE ENTERPRISE mibObjects DESCRIPTION "Login OK" ::= 60 resetComplete TRAP-TYPE ENTERPRISE mibObjects DESCRIPTION "Reset Complete" ::= 80 ethernetConnectionRestored TRAP-TYPE ENTERPRISE mibObjects DESCRIPTION "Ethernet Connection Restored" ::= 99 END