-- MIB for Dantherm Cooling Controllers DANTHERM-COOLING-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 enterprises FROM RFC1155-SMI; -- -- Product and Data group Definitions danthermCooling OBJECT IDENTIFIER ::= { enterprises 46651 } -- -- Product CC3000 Controller Definitions controllerCC3000 OBJECT IDENTIFIER ::= { danthermCooling 1 } systemStatus OBJECT IDENTIFIER ::= { controllerCC3000 1 } highlevelControl OBJECT IDENTIFIER ::= { controllerCC3000 2 } fan1Config OBJECT IDENTIFIER ::= { controllerCC3000 3 } fan2Config OBJECT IDENTIFIER ::= { controllerCC3000 4 } damper1Config OBJECT IDENTIFIER ::= { controllerCC3000 5 } damper2Config OBJECT IDENTIFIER ::= { controllerCC3000 6 } aircon1Config OBJECT IDENTIFIER ::= { controllerCC3000 7 } aircon2Config OBJECT IDENTIFIER ::= { controllerCC3000 8 } heaterConfig OBJECT IDENTIFIER ::= { controllerCC3000 9 } humidityConfig OBJECT IDENTIFIER ::= { controllerCC3000 10 } systemConfig OBJECT IDENTIFIER ::= { controllerCC3000 11 } alarmConfig OBJECT IDENTIFIER ::= { controllerCC3000 12 } nightModeConfig OBJECT IDENTIFIER ::= { controllerCC3000 13 } networkConfig OBJECT IDENTIFIER ::= { controllerCC3000 14 } trapError OBJECT IDENTIFIER ::= { controllerCC3000 15 } -- Product CCxx Controller Definitions --controllerCCxx OBJECT IDENTIFIER ::= { danthermCooling x } -- -- Controller-CC3000 : systemStatus onBoardTempr OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-only STATUS mandatory DESCRIPTION "Controller On-Board temperature in Degree Celcius " ::= { systemStatus 1 } roomTempr OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-only STATUS mandatory DESCRIPTION "Room Sensor or Zone 1 Sensor temperature in Degree Celcius" ::= { systemStatus 2 } hotSpotTempr OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-only STATUS mandatory DESCRIPTION "Hot Spot Sensor or Zone 2 Sensor temperature in Degree Celcius" ::= { systemStatus 3 } outdoor1Tempr OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-only STATUS mandatory DESCRIPTION "Ambient Sensor 1 or Zone 1 Ambient Sensor. temperature in Degree Celcius" ::= { systemStatus 4 } outdoor2Tempr OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-only STATUS mandatory DESCRIPTION "Ambient Sensor 2 or Zone 2 Ambient Sensor. temperature in Degree Celcius" ::= { systemStatus 5 } shelterTempr OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-only STATUS mandatory DESCRIPTION "Shelter Temperature. Valid for Single-Zone solution" ::= { systemStatus 6 } outdoorCombinedTempr OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-only STATUS mandatory DESCRIPTION "Cobined minimum Outdoor Temeperature. Valid for Single-Zone solution" ::= { systemStatus 7 } fan1RPM OBJECT-TYPE SYNTAX INTEGER(0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "Fan 1 Rotation Per Minute" ::= { systemStatus 8 } fan2RPM OBJECT-TYPE SYNTAX INTEGER(0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "Fan 2 Rotation Per Minute" ::= { systemStatus 9 } fan1SpeedPercentage OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Fan 1 Speed in Percentage of Maximum Speed. Also represents Duty-Cycle of FAn Signal " ::= { systemStatus 10 } fan2SpeedPercentage OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Fan 2 Speed in Percentage of Maximum Speed. Also represents Duty-Cycle of FAn Signal " ::= { systemStatus 11 } damper1Position OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Damper 1 Shutter Open Percentage. 0% - Damper Closed. 100% - Damper completely open" ::= { systemStatus 12 } damper2Position OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Damper 2 Shutter Open Percentage. 0% - Damper Closed. 100% - Damper completely open" ::= { systemStatus 13 } humidity OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Internal or external humidity in Rh%" ::= { systemStatus 14 } dewpoint OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-only STATUS mandatory DESCRIPTION "Internal or external DewPoint based on Humidity; in Degree Celcius" ::= { systemStatus 15 } atmosphericPressure OBJECT-TYPE SYNTAX INTEGER(0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "Atmospheric pressure or Pressure of installed enclosure in KiloPascal" ::= { systemStatus 16 } flowPressure OBJECT-TYPE SYNTAX INTEGER(-1000..1000) ACCESS read-only STATUS mandatory DESCRIPTION "Filter flow Pressure in Pascal" ::= { systemStatus 17 } fan1Status OBJECT-TYPE SYNTAX INTEGER(0..2) ACCESS read-only STATUS mandatory DESCRIPTION "Fan 1 operation status. 0 - Off; 1 - On -; 2 - Emergency/Boost " ::= { systemStatus 18 } fan2Status OBJECT-TYPE SYNTAX INTEGER(0..2) ACCESS read-only STATUS mandatory DESCRIPTION "Fan 2 operation status. 0 - Off; 1 - On -; 2 - Emergency/Boost " ::= { systemStatus 19 } damper1Status OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Damper 1 operation status. 0 - Closed; 1 - Open; 2 - Dynamic or Temperature Compensation; 2 - Emergency/Boost " ::= { systemStatus 20 } damper2Status OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Damper 2 Shutter Open Percentage. 0 - Closed; 1 - Open; 2 - Dynamic or Temperature Compensation; 2 - Emergency/Boost " ::= { systemStatus 21 } aircond1Status OBJECT-TYPE SYNTAX INTEGER(0..2) ACCESS read-only STATUS mandatory DESCRIPTION "Airconditioner 1 operation status. 0 - Off; 1 - Restart timeout; 2 - On " ::= { systemStatus 22 } aircond2Status OBJECT-TYPE SYNTAX INTEGER(0..2) ACCESS read-only STATUS mandatory DESCRIPTION "Airconditioner 2 operation status. 0 - Off; 1 - Restart timeout; 2 - On " ::= { systemStatus 23 } heaterStatus OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-only STATUS mandatory DESCRIPTION "heater operation status. 0 - Off; 1 - On " ::= { systemStatus 24 } shelter1Status OBJECT-TYPE SYNTAX INTEGER(0..6) ACCESS read-only STATUS mandatory DESCRIPTION "Shelter Status in Single-Zone mode or Zone 1 Status in Dual-Zone mode respectively. 0 - Inactive or None State 1 - Heating State 2 - Re-Cycling State 3 - Free Cooling State 4 - Active or Aircon Coolign State 5 - Emergency State 6 - Intermediate state( strategy transistion) " ::= { systemStatus 25 } shelter2Status OBJECT-TYPE SYNTAX INTEGER(0..6) ACCESS read-only STATUS mandatory DESCRIPTION "Shelter Status in Dual-Zone mode or Zone 2 Status. 0 - Inactive or None State 1 - Heating State 2 - Re-Cycling State 3 - Free Cooling State 4 - Active or Aircon Coolign State 5 - Emergency State 6 - Intermediate state( strategy transistion) " ::= { systemStatus 26 } shelter1Mode OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Shelter Run time mode in Single-Zone mode or Zone 1 Status in Dual-Zone mode respectively. 0 - Free Cooling Mode 1 - Standard Mode 2 - Power Save Mode 3 - Air conditioner Mode " ::= { systemStatus 27 } shelter2Mode OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Shelter Run time mode in Dual-Zone mode or Zone 2 Status. 0 - Free Cooling Mode 1 - Standard Mode 2 - Power Save Mode 3 - Air conditioner Mode " ::= { systemStatus 28 } shelter1Setpoint OBJECT-TYPE SYNTAX INTEGER(-41..80) ACCESS read-only STATUS mandatory DESCRIPTION "Shelter run time Cooling Set point in Single-Zone mode or Zone 1 Status in Dual-Zone mode respectively. Cooling setpoint can be offset by following functions RH function Night mode Digital inputs " ::= { systemStatus 29 } shelter2Setpoint OBJECT-TYPE SYNTAX INTEGER(-41..80) ACCESS read-only STATUS mandatory DESCRIPTION "Shelter run time Cooling Set point in Dual-Zone mode or Zone 2 Status. Cooling setpoint can be offset by following functions RH function Night mode Digital inputs " ::= { systemStatus 30 } errorStatus OBJECT-TYPE SYNTAX INTEGER(0..33554432) ACCESS read-only STATUS mandatory DESCRIPTION " controller internal error status. Binary bit position - alarm drive state: 0 - inactive , 1 - active 0 - voltage low 1 - voltage high 2 - tempr low 3 - tempr limit 1 4 - tempr limit 2 5 - tempr limit 3 6 - humid. low 7 - humid. high 8 - fltr pressure 1 9 - fltr pressure 2 10 - fan 1 11 - fan 2 12 - onboard sens 13 - room sens 14 - hotspot sens 15 - ambient 1 sens 16 - ambient 2 sens 17 - dig 1 i/p 18 - dig 2 i/p 19 - dig 3 i/p 20 - filter i/p 1 21 - filter i/p 2 22 - network 23 - int storage 24 - sd card " ::= { systemStatus 31 } maskedErrorStatus OBJECT-TYPE SYNTAX INTEGER(0..33554432) ACCESS read-only STATUS mandatory DESCRIPTION " Controller Output Error status. Binary Bit Position - Alarm Drive State: 0 - Inactive , 1 - Active 0 - Voltage Low 1 - Voltage High 2 - Tempr Low 3 - Tempr Limit 1 4 - Tempr Limit 2 5 - Tempr Limit 3 6 - Humid. Low 7 - Humid. High 8 - Fltr Pressure 1 9 - Fltr Pressure 2 10 - Fan 1 11 - Fan 2 12 - Onboard Sens 13 - Room Sens 14 - Hotspot Sens 15 - Ambient 1 Sens 16 - Ambient 2 Sens 17 - Dig 1 I/P 18 - Dig 2 I/P 19 - Dig 3 I/P 20 - Filter I/P 1 21 - Filter I/P 2 22 - Network 23 - Int storage 24 - SD Card " ::= { systemStatus 32 } voltage OBJECT-TYPE SYNTAX INTEGER(0..80) ACCESS read-only STATUS mandatory DESCRIPTION "System Voltage in DC. " ::= { systemStatus 33 } digitalInputStatus OBJECT-TYPE SYNTAX INTEGER(0..16) ACCESS read-only STATUS mandatory DESCRIPTION " Controller Alarm Drive Status. Binary Bit Position - Digital Input State: 0 - Inactive , 1 - Active 0 - DIG 1 I/P 1 - DIG 2 I/P 2 - DIG 3 I/P 3 - FILTER GUARD DIGI 1 I/P 4 - FILTER GUARD DIGI 2 I/P " ::= { systemStatus 34 } alarmDriveStatus OBJECT-TYPE SYNTAX INTEGER(0..1024) ACCESS read-only STATUS mandatory DESCRIPTION " Controller Alarm Drive Status. Binary Bit Position - Alarm Drive State: 0 - Inactive , 1 - Active 0 - ALARM 1 1 - ALARM 2 2 - ALARM 3 3 - ALARM 4 4 - ALARM 5 5 - ALARM 6 6 - ALARM 7 7 - ALARM 8 8 - ALARM 9 9 - ALARM 10" ::= { systemStatus 35 } fan1OpertdurHour OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Fan 1 operation duration - Hour " ::= { systemStatus 36 } fan1OpertdurMin OBJECT-TYPE SYNTAX INTEGER(0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Fan 1 operation duration - Minute " ::= { systemStatus 37 } fan2OpertdurHour OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Fan 2 operation duration - Hour " ::= { systemStatus 38 } fan2OpertdurMin OBJECT-TYPE SYNTAX INTEGER(0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Fan 2 operation duration - Minute " ::= { systemStatus 39 } aircon1OpertdurHour OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Airconditioner 1 operation duration - Hour " ::= { systemStatus 40 } aircon1OpertdurMin OBJECT-TYPE SYNTAX INTEGER(0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Airconditioner 1 operation duration - Minute " ::= { systemStatus 41 } aircon2OpertdurHour OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Airconditioner 2 operation duration - Hour " ::= { systemStatus 42 } aircon2OpertdurMin OBJECT-TYPE SYNTAX INTEGER(0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Airconditioner 2 operation duration - Minute " ::= { systemStatus 43 } heaterOpertdurHour OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Heater operation duration - Hour " ::= { systemStatus 44 } heaterOpertdurMin OBJECT-TYPE SYNTAX INTEGER(0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Heater operation duration - Minute " ::= { systemStatus 45 } ccSN OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "CC3000 Controller serial number " ::= { systemStatus 46 } fanbox1SN OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Free cooling FanBox unit 1 serial number " ::= { systemStatus 47 } fanbox2SN OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Free cooling FanBox unit 2 serial number " ::= { systemStatus 48 } aircond1SN OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Aicodnitioner unit 1 serial number " ::= { systemStatus 49 } aircond2SN OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Aicodnitioner unit 2 serial number " ::= { systemStatus 50 } fwVersion OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "CC3000 Firmware version " ::= { systemStatus 51 } -- -- Controller-CC3000 : highlevelControl coolSetpointZone1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Cooling Setpoint Zone/Shelter 1 " ::= { highlevelControl 1 } coolSetpointZone2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Cooling Setpoint Zone/Shelter 2 " ::= { highlevelControl 2 } heaterSetpoint OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Heater Setpoint " ::= { highlevelControl 3 } backupConfig OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Configuration Backup to Internal memory and SD card. 0 - No change, 1 - Backup " ::= { highlevelControl 4 } restoreConfig OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Configuration restore from Internal memory. 0 - No change, 1 - Restore " ::= { highlevelControl 5 } systemReset OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Colling System reset or restart. 0 - No change, 1 - Restart " ::= { highlevelControl 6 } year OBJECT-TYPE SYNTAX INTEGER(2015..2099) ACCESS read-write STATUS mandatory DESCRIPTION "Calender - Year " ::= { highlevelControl 7 } month OBJECT-TYPE SYNTAX INTEGER(1..12) ACCESS read-write STATUS mandatory DESCRIPTION "Calender - Month " ::= { highlevelControl 8 } date OBJECT-TYPE SYNTAX INTEGER(1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Calender - Date " ::= { highlevelControl 9 } hour OBJECT-TYPE SYNTAX INTEGER(0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock - Hour " ::= { highlevelControl 10 } minute OBJECT-TYPE SYNTAX INTEGER(0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock - Minute " ::= { highlevelControl 11 } -- -- Controller-CC3000 : fan1Config saveReloadConff1 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Discard modifications, 1 - Save Modifications. Configuration reloaded " ::= { fan1Config 1 } offTemprf1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Fan OFF temperature " ::= { fan1Config 2 } idleOnTemprf1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Fan Idle Speed On temperature " ::= { fan1Config 3 } idleEntryTemprf1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Idle entry temperature " ::= { fan1Config 4 } midPoint1Temprf1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Mid point 1 entry temperature " ::= { fan1Config 5 } setPointTemprf1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Set Point temperature " ::= { fan1Config 6 } midPoint2Temprf1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Mid point 2 entry temperature " ::= { fan1Config 7 } highSpeedTemprf1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "high Speed entry temperature " ::= { fan1Config 8 } extendHighSpeedEntryTemprf1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Extended high Speed entry temperature " ::= { fan1Config 9 } extendHighSpeedExitTemprf1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Extended high Speed exit temperature " ::= { fan1Config 10 } boostEntryTemprf1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Boost Speed entry temperature " ::= { fan1Config 11 } boostExitTemprf1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Boost Speed entry temperature " ::= { fan1Config 12 } idleRPMf1 OBJECT-TYPE SYNTAX INTEGER(0..9999) ACCESS read-write STATUS mandatory DESCRIPTION "Idle speed RPM " ::= { fan1Config 13 } midPointRPMf1 OBJECT-TYPE SYNTAX INTEGER(0..9999) ACCESS read-write STATUS mandatory DESCRIPTION "Midpoint Speed RPM " ::= { fan1Config 14 } highSpeedRPMf1 OBJECT-TYPE SYNTAX INTEGER(0..9999) ACCESS read-write STATUS mandatory DESCRIPTION "high Speed RPM " ::= { fan1Config 15 } extendHighSpeedRPMf1 OBJECT-TYPE SYNTAX INTEGER(0..9999) ACCESS read-write STATUS mandatory DESCRIPTION "Extended high Speed RPM " ::= { fan1Config 16 } idleDutyCyclef1 OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Idle Speed Duty Cycle " ::= { fan1Config 17 } midDutyCyclef1 OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Midpoint speed Duty Cycle " ::= { fan1Config 18 } highSpeedDutyCyclef1 OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION "high speed Duty Cycle " ::= { fan1Config 19 } extendHighSpeedDutyCyclef1 OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Extended high speed Duty Cycle " ::= { fan1Config 20 } boostDutyCyclef1 OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Boost speed Duty Cycle " ::= { fan1Config 21 } deadBandRPMf1 OBJECT-TYPE SYNTAX INTEGER(0..1000) ACCESS read-write STATUS mandatory DESCRIPTION "Dead band RPM " ::= { fan1Config 22 } overrideDigi1f1 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0-100 - Fan Speed in Duty cycle. 120 - No action on Over ride. " ::= { fan1Config 23 } overrideDigi2f1 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0-100 - Fan Speed in Duty cycle. 120 - No action on Over ride. " ::= { fan1Config 24 } overrideDigi3f1 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0-100 - Fan Speed in Duty cycle. 120 - No action on Over ride. " ::= { fan1Config 25 } overrideSensorfailf1 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0-100 - Fan Speed in Duty cycle. 120 - No action on Over ride. " ::= { fan1Config 26 } sensorSelectf1 OBJECT-TYPE SYNTAX INTEGER(0..5) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Onboard sensor. 1 - Room Sensor. 2 - Hotspot sensor. 3 - Ambient 2 sensor. 4 - Ambient 1 sensor. 5 - Shelter temperature " ::= { fan1Config 27 } tachoPulseperrotationf1 OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Number of Tacho pulses per cycle rotation for given fan " ::= { fan1Config 28 } closedLoopenablef1 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Closed Loop control enable or disable for given Fan. 0 - Enable. 1 - Disable " ::= { fan1Config 29 } controlTypef1 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - 0-10V DC control. 1 - PWM control " ::= { fan1Config 30 } enablef1 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - Disable Fan control. 1 - Enabel fan control " ::= { fan1Config 31 } -- -- Controller-CC3000 : fan2Config saveReloadConff2 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Discard modifications, 1 - Save Modifications. Configuration reloaded " ::= { fan2Config 1 } offTemprf2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Fan OFF temperature " ::= { fan2Config 2 } idleOnTemprf2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Fan Idle Speed On temperature " ::= { fan2Config 3 } idleEntryTemprf2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Idle entry temperature " ::= { fan2Config 4 } midPoint1Temprf2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Mid point 1 entry temperature " ::= { fan2Config 5 } setPointTemprf2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Set Point temperature " ::= { fan2Config 6 } midPoint2Temprf2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Mid point 2 entry temperature " ::= { fan2Config 7 } highSpeedTemprf2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "high Speed entry temperature " ::= { fan2Config 8 } extendHighSpeedEntryTemprf2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Extended high Speed entry temperature " ::= { fan2Config 9 } extendHighSpeedExitTemprf2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Extended high Speed exit temperature " ::= { fan2Config 10 } boostEntryTemprf2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Boost Speed entry temperature " ::= { fan2Config 11 } boostExitTemprf2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION "Boost Speed entry temperature " ::= { fan2Config 12 } idleRPMf2 OBJECT-TYPE SYNTAX INTEGER(0..9999) ACCESS read-write STATUS mandatory DESCRIPTION "Idle speed RPM " ::= { fan2Config 13 } midPointRPMf2 OBJECT-TYPE SYNTAX INTEGER(0..9999) ACCESS read-write STATUS mandatory DESCRIPTION "Midpoint Speed RPM " ::= { fan2Config 14 } highSpeedRPMf2 OBJECT-TYPE SYNTAX INTEGER(0..9999) ACCESS read-write STATUS mandatory DESCRIPTION "high Speed RPM " ::= { fan2Config 15 } extendHighSpeedRPMf2 OBJECT-TYPE SYNTAX INTEGER(0..9999) ACCESS read-write STATUS mandatory DESCRIPTION "Extended high Speed RPM " ::= { fan2Config 16 } idleDutyCyclef2 OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Idle Speed Duty Cycle " ::= { fan2Config 17 } midDutyCyclef2 OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Midpoint speed Duty Cycle " ::= { fan2Config 18 } highSpeedDutyCyclef2 OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION "high speed Duty Cycle " ::= { fan2Config 19 } extendHighSpeedDutyCyclef2 OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Extended high speed Duty Cycle " ::= { fan2Config 20 } boostDutyCyclef2 OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Boost speed Duty Cycle " ::= { fan2Config 21 } deadBandRPMf2 OBJECT-TYPE SYNTAX INTEGER(0..1000) ACCESS read-write STATUS mandatory DESCRIPTION "Dead band RPM " ::= { fan2Config 22 } overrideDigi1f2 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0-100 - Fan Speed in Duty cycle. 120 - No action on Over ride. " ::= { fan2Config 23 } overrideDigi2f2 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0-100 - Fan Speed in Duty cycle. 120 - No action on Over ride. " ::= { fan2Config 24 } overrideDigi3f2 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0-100 - Fan Speed in Duty cycle. 120 - No action on Over ride. " ::= { fan2Config 25 } overrideSensorfailf2 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0-100 - Fan Speed in Duty cycle. 120 - No action on Over ride. " ::= { fan2Config 26 } sensorSelectf2 OBJECT-TYPE SYNTAX INTEGER(0..5) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Onboard sensor. 1 - Room Sensor. 2 - Hotspot sensor. 3 - Ambient 2 sensor. 4 - Ambient 1 sensor. 5 - Shelter temperature " ::= { fan2Config 27 } tachoPulseperrotationf2 OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Number of Tacho pulses per cycle rotation for given fan " ::= { fan2Config 28 } closedLoopenablef2 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "Closed Loop control enable or disable for given Fan. 0 - Enable. 1 - Disable " ::= { fan2Config 29 } controlTypef2 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - 0-10V DC control. 1 - PWM control" ::= { fan2Config 30 } enablef2 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - Disable Fan control. 1 - Enabel fan control " ::= { fan2Config 31 } -- -- Controller-CC3000 : damper1Config saveReloadConfd1 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Discard modifications, 1 - Save Modifications. Configuration reloaded " ::= { damper1Config 1 } lowercloseTemprd1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION " Damper lower closing temperature " ::= { damper1Config 2 } setPointd1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION " Damper opening temperature " ::= { damper1Config 3 } upperOpentempd1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION " Damper upper opening temperature " ::= { damper1Config 4 } upperClosetempd1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION " Damper upper closing temperature " ::= { damper1Config 5 } emgncyClosetempd1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION " Damper emergency closing temperature " ::= { damper1Config 6 } emgncyopentempd1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION " Damper emergency open temperature " ::= { damper1Config 7 } overrideDigi1d1 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Damper close. 1 - Damper open. 120 - No action on Over ride. " ::= { damper1Config 8 } overrideDigi2d1 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Damper close. 1 - Damper open. 120 - No action on Over ride. " ::= { damper1Config 9 } overrideDigi3d1 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Damper close. 1 - Damper open. 120 - No action on Over ride. " ::= { damper1Config 10 } overrideSensorFaild1 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Damper close. 1 - Damper open. 120 - No action on Over ride. " ::= { damper1Config 11 } sensSelectd1 OBJECT-TYPE SYNTAX INTEGER(0..5) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Onboard sensor. 1 - Room Sensor. 2 - Hotspot sensor. 3 - Ambient 2 sensor. 4 - Ambient 1 sensor. 5 - Shelter temperature " ::= { damper1Config 12 } runDurationd1 OBJECT-TYPE SYNTAX INTEGER(30..300) ACCESS read-write STATUS mandatory DESCRIPTION "Damper Run time in minutes " ::= { damper1Config 13 } enabled1 OBJECT-TYPE SYNTAX INTEGER(0..2) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Disable. 1 - ONOFF. 2 - Dynamic " ::= { damper1Config 14 } -- --Controller-CC3000 : damper2Config saveReloadConfd2 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Discard modifications, 1 - Save Modifications. Configuration reloaded " ::= { damper2Config 1 } lowercloseTemprd2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION " Damper lower closing temperature " ::= { damper2Config 2 } setPointd2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION " Damper opening temperature " ::= { damper2Config 3 } upperOpentempd2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION " Damper upper opening temperature " ::= { damper2Config 4 } upperClosetempd2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION " Damper upper closing temperature " ::= { damper2Config 5 } emgncyClosetempd2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION " Damper emergency closing temperature " ::= { damper2Config 6 } emgncyopentempd2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION " Damper emergency open temperature " ::= { damper2Config 7 } overrideDigi1d2 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Damper close. 1 - Damper open. 120 - No action on Over ride. " ::= { damper2Config 8 } overrideDigi2d2 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Damper close. 1 - Damper open. 120 - No action on Over ride. " ::= { damper2Config 9 } overrideDigi3d2 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Damper close. 1 - Damper open. 120 - No action on Over ride. " ::= { damper2Config 10 } overrideSensorFaild2 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Damper close. 1 - Damper open. 120 - No action on Over ride. " ::= { damper2Config 11 } sensSelectd2 OBJECT-TYPE SYNTAX INTEGER(0..5) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Onboard sensor. 1 - Room Sensor. 2 - Hotspot sensor. 3 - Ambient 2 sensor. 4 - Ambient 1 sensor. 5 - Shelter temperature " ::= { damper2Config 12 } runDurationd2 OBJECT-TYPE SYNTAX INTEGER(30..300) ACCESS read-write STATUS mandatory DESCRIPTION "Damper Run time in minutes " ::= { damper2Config 13 } enabled2 OBJECT-TYPE SYNTAX INTEGER(0..2) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Disable. 1 - ONOFF. 2 - Dynamic " ::= { damper2Config 14 } -- -- Controller-CC3000 : AC-1-Config saveReloadConfac1 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Discard modifications, 1 - Save Modifications. Configuration reloaded " ::= { aircon1Config 1 } oNTemprac1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION " Air Conditioner ON temperature " ::= { aircon1Config 2 } oFFTemprac1 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION " Air Conditioner OFF temperature " ::= { aircon1Config 3 } overrideDigi1ac1 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - AC OFF. 1 - AC ON. 120 - No action on Over ride. " ::= { aircon1Config 4 } overrideDigi2ac1 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - AC OFF. 1 - AC ON. 120 - No action on Over ride. " ::= { aircon1Config 5 } overrideDigi3ac1 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - AC OFF. 1 - AC ON. 120 - No action on Over ride " ::= { aircon1Config 6 } overrideSensorFailac1 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - AC OFF. 1 - AC ON. 120 - No action on Over ride " ::= { aircon1Config 7 } sensSelectac1 OBJECT-TYPE SYNTAX INTEGER(0..5) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Onboard sensor. 1 - Room Sensor. 2 - Hotspot sensor. 3 - Ambient 2 sensor. 4 - Ambient 1 sensor. 5 - Shelter temperature " ::= { aircon1Config 8 } minimumRunDurationac1 OBJECT-TYPE SYNTAX INTEGER(60..3600) ACCESS read-write STATUS mandatory DESCRIPTION "Minimum AC Run time in seconds " ::= { aircon1Config 9 } restartTimeoutac1 OBJECT-TYPE SYNTAX INTEGER(60..3600) ACCESS read-write STATUS mandatory DESCRIPTION "Restart timer in seconds " ::= { aircon1Config 10 } enableac1 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Disable. 1 - Enable. " ::= { aircon1Config 11 } -- -- Controller-CC3000 : aircon2Config saveReloadConfac2 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Discard modifications, 1 - Save Modifications. Configuration reloaded " ::= { aircon2Config 1 } onTemprac2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION " Air Conditioner ON temperature " ::= { aircon2Config 2 } offTemprac2 OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION " Air Conditioner OFF temperature " ::= { aircon2Config 3 } overrideDigi1ac2 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - AC OFF. 1 - AC ON. 120 - No action on Over ride. " ::= { aircon2Config 4 } overrideDigi2ac2 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - AC OFF. 1 - AC ON. 120 - No action on Over ride. " ::= { aircon2Config 5 } overrideDigi3ac2 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - AC OFF. 1 - AC ON. 120 - No action on Over ride " ::= { aircon2Config 6 } overrideSensorFailac2 OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - AC OFF. 1 - AC ON. 120 - No action on Over ride " ::= { aircon2Config 7 } sensSelectac2 OBJECT-TYPE SYNTAX INTEGER(0..5) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Onboard sensor. 1 - Room Sensor. 2 - Hotspot sensor. 3 - Ambient 2 sensor. 4 - Ambient 1 sensor. 5 - Shelter temperature " ::= { aircon2Config 8 } minimumRunDurationac2 OBJECT-TYPE SYNTAX INTEGER(60..3600) ACCESS read-write STATUS mandatory DESCRIPTION "Minimum AC Run time in seconds " ::= { aircon2Config 9 } restartTimeoutac2 OBJECT-TYPE SYNTAX INTEGER(60..3600) ACCESS read-write STATUS mandatory DESCRIPTION "Restart timer in seconds " ::= { aircon2Config 10 } enableac2 OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Disable. 1 - Enable. " ::= { aircon2Config 11 } -- -- Controller-CC3000 : heaterConfig saveReloadConfhtr OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Discard modifications, 1 - Save Modifications. Configuration reloaded " ::= { heaterConfig 1 } onTemprhtr OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION " Heater ON temperature " ::= { heaterConfig 2 } offTemprhtr OBJECT-TYPE SYNTAX INTEGER(-41..101) ACCESS read-write STATUS mandatory DESCRIPTION " Heater OFF temperature " ::= { heaterConfig 3 } overrideDigi1htr OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Heat OFF. 1 - Heat ON. 120 - No action on Over ride. " ::= { heaterConfig 4 } overrideDigi2htr OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Heat OFF. 1 - Heat ON. 120 - No action on Over ride. " ::= { heaterConfig 5 } overrideDigi3htr OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Heat OFF. 1 - Heat ON. 120 - No action on Over ride " ::= { heaterConfig 6 } overrideSensorFailhtr OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Heat OFF. 1 - Heat ON. 120 - No action on Over ride " ::= { heaterConfig 7 } sensSelecthtr OBJECT-TYPE SYNTAX INTEGER(0..5) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Onboard sensor. 1 - Room Sensor. 2 - Hotspot sensor. 3 - Ambient 2 sensor. 4 - Ambient 1 sensor. 5 - Shelter temperature " ::= { heaterConfig 8 } enablehtr OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Disable. 1 - Enable. " ::= { heaterConfig 9 } -- -- Controller-CC3000 : humidityConfig saveReloadConfhum OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Discard modifications, 1 - Save Modifications. Configuration reloaded " ::= { humidityConfig 1 } rhEntryhum OBJECT-TYPE SYNTAX INTEGER(40..100) ACCESS read-write STATUS mandatory DESCRIPTION " Humidity function entry value " ::= { humidityConfig 2 } rhExithum OBJECT-TYPE SYNTAX INTEGER(40..100) ACCESS read-write STATUS mandatory DESCRIPTION " Humidity function exit value " ::= { humidityConfig 3 } coolingmodehum OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Freecooling. 1 - Standard. 2 - Power save. 3 - Aircon. " ::= { humidityConfig 4 } temprsetpoffsethum OBJECT-TYPE SYNTAX INTEGER(-10..10) ACCESS read-write STATUS mandatory DESCRIPTION " Cooling setpoint offset " ::= { humidityConfig 5 } rhSensPositionhum OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Indoor. 1 - Outdoor " ::= { humidityConfig 6 } enablehum OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Disable. 1 - Enable. " ::= { humidityConfig 7 } -- -- Controller-CC3000 : systemConfig saveReloadConfsysc OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Discard modifications, 1 - Save Modifications. Configuration reloaded " ::= { systemConfig 1 } vdcLowEntrysys OBJECT-TYPE SYNTAX INTEGER(18..60) ACCESS read-write STATUS mandatory DESCRIPTION " Low voltage shut down entry " ::= { systemConfig 2 } vdcLowExitsys OBJECT-TYPE SYNTAX INTEGER(18..60) ACCESS read-write STATUS mandatory DESCRIPTION " Low voltage shut down exit " ::= { systemConfig 3 } vdcHighEntrysys OBJECT-TYPE SYNTAX INTEGER(18..60) ACCESS read-write STATUS mandatory DESCRIPTION " High voltage shut down entry " ::= { systemConfig 4 } vdcHighExitsys OBJECT-TYPE SYNTAX INTEGER(18..60) ACCESS read-write STATUS mandatory DESCRIPTION " High voltage shut down exit " ::= { systemConfig 5 } temprLowlimitsys OBJECT-TYPE SYNTAX INTEGER(-40..80) ACCESS read-write STATUS mandatory DESCRIPTION " Low temperature alarm limit " ::= { systemConfig 6 } temprHighlimit1sys OBJECT-TYPE SYNTAX INTEGER(-40..80) ACCESS read-write STATUS mandatory DESCRIPTION " High temperature alarm limit 1 " ::= { systemConfig 7 } temprHighlimit2sys OBJECT-TYPE SYNTAX INTEGER(-40..80) ACCESS read-write STATUS mandatory DESCRIPTION " High temperature alarm limit 2 " ::= { systemConfig 8 } temprHighlimit3sys OBJECT-TYPE SYNTAX INTEGER(-40..80) ACCESS read-write STATUS mandatory DESCRIPTION " High temperature alarm limit 3 " ::= { systemConfig 9 } temprlimithyssys OBJECT-TYPE SYNTAX INTEGER(-20..20) ACCESS read-write STATUS mandatory DESCRIPTION " Temperature alarm limit hysteresis " ::= { systemConfig 10 } rhLowlimitsys OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION " Humidity alarm low limit %RH " ::= { systemConfig 11 } rhHighlimitsys OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION " Humidity alarm High limit %RH " ::= { systemConfig 12 } flowpresslimit1sys OBJECT-TYPE SYNTAX INTEGER(60..400) ACCESS read-write STATUS mandatory DESCRIPTION " Flow pressure limit 1 Pa " ::= { systemConfig 13 } flowpresslimit2sys OBJECT-TYPE SYNTAX INTEGER(60..400) ACCESS read-write STATUS mandatory DESCRIPTION " Flow pressure limit 2 Pa " ::= { systemConfig 14 } flowpresshyssys OBJECT-TYPE SYNTAX INTEGER(0..400) ACCESS read-write STATUS mandatory DESCRIPTION " Flow pressure limit hysteresis Pa " ::= { systemConfig 15 } coolingzonessys OBJECT-TYPE SYNTAX INTEGER(1..2) ACCESS read-write STATUS mandatory DESCRIPTION " 1 - One cooling zone, 2 - Two cooling zones " ::= { systemConfig 16 } coolingModesys OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - FC, 1 - Std, 2 - Ps, 3 - Acon " ::= { systemConfig 17 } negCoolingDeltaOverridesys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - Disable, 1 - Enable " ::= { systemConfig 18 } negCoolingDeltaHyssys OBJECT-TYPE SYNTAX INTEGER(-10..10) ACCESS read-write STATUS mandatory DESCRIPTION " Negative cooling delta hysteresis " ::= { systemConfig 19 } coolingDeltatempsys OBJECT-TYPE SYNTAX INTEGER(-10..10) ACCESS read-write STATUS mandatory DESCRIPTION " Cooling delta temperature " ::= { systemConfig 20 } shelterTemprsys OBJECT-TYPE SYNTAX INTEGER(0..2) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - RA, 1 - HS, 2 - Both " ::= { systemConfig 21 } acleadlagsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - Disable, 1 - Enable " ::= { systemConfig 22 } coolingModeXzonesys OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - FC, 1 - Std, 2 - Ps, 3 - Acon " ::= { systemConfig 23 } negCoolingDeltaOverrideXzonesys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - Disable, 1 - Enable " ::= { systemConfig 24 } negCoolingDeltaHysXzonesys OBJECT-TYPE SYNTAX INTEGER(-10..10) ACCESS read-write STATUS mandatory DESCRIPTION " Negative cooling delta hysteresis " ::= { systemConfig 25 } coolingDeltatempXzonesys OBJECT-TYPE SYNTAX INTEGER(-10..10) ACCESS read-write STATUS mandatory DESCRIPTION " Cooling delta temperature " ::= { systemConfig 26 } fan1Zonesys OBJECT-TYPE SYNTAX INTEGER(1..2) ACCESS read-write STATUS mandatory DESCRIPTION " 1 - Fan 1 for Zone 1, 2 - Fan 1 for zone 2 " ::= { systemConfig 27 } fan2Zonesys OBJECT-TYPE SYNTAX INTEGER(1..2) ACCESS read-write STATUS mandatory DESCRIPTION " 1 - Fan 2 for Zone 1, 2 - Fan 2 for zone 2 " ::= { systemConfig 28 } ac1Zonesys OBJECT-TYPE SYNTAX INTEGER(1..2) ACCESS read-write STATUS mandatory DESCRIPTION " 1 - AC 1 for Zone 1, 2 - AC 1 for zone 2 " ::= { systemConfig 29 } ac2Zonesys OBJECT-TYPE SYNTAX INTEGER(1..2) ACCESS read-write STATUS mandatory DESCRIPTION " 1 - AC 2 for Zone 1, 2 - AC 2 for zone 2 " ::= { systemConfig 30 } damper1Zonesys OBJECT-TYPE SYNTAX INTEGER(1..2) ACCESS read-write STATUS mandatory DESCRIPTION " 1 - Damper 1 for Zone 1, 2 - Damper 1 for zone 2 " ::= { systemConfig 31 } damper2Zonesys OBJECT-TYPE SYNTAX INTEGER(1..2) ACCESS read-write STATUS mandatory DESCRIPTION " 1 - Damper 2 for Zone 1, 2 - Damper 2 for zone 2 " ::= { systemConfig 32 } heaterZonesys OBJECT-TYPE SYNTAX INTEGER(1..2) ACCESS read-write STATUS mandatory DESCRIPTION " 1 - Heater for Zone 1, 2 - Heater for zone 2 " ::= { systemConfig 33 } statusLogsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - Disable, 1 - Enable " ::= { systemConfig 34 } logintervalsys OBJECT-TYPE SYNTAX INTEGER(1..60) ACCESS read-write STATUS mandatory DESCRIPTION " Log interval in minutes " ::= { systemConfig 35 } alarm1NONCsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - NO, 1 - NC " ::= { systemConfig 36 } alarm2NONCsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - NO, 1 - NC " ::= { systemConfig 37 } alarm3NONCsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - NO, 1 - NC " ::= { systemConfig 38 } alarm4NONCsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - NO, 1 - NC " ::= { systemConfig 39 } alarm5NONCsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - NO, 1 - NC " ::= { systemConfig 40 } alarm6NONCsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - NO, 1 - NC " ::= { systemConfig 41 } alarm7NONCsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - NO, 1 - NC " ::= { systemConfig 42 } alarm8NONCsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - NO, 1 - NC " ::= { systemConfig 43 } alarm9NONCsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - NO, 1 - NC " ::= { systemConfig 44 } alarm10NONCsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - NO, 1 - NC " ::= { systemConfig 45 } alarm1Delaysys OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm output delay in seconds " ::= { systemConfig 46 } alarm2Delaysys OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm output delay in seconds " ::= { systemConfig 47 } alarm3Delaysys OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm output delay in seconds " ::= { systemConfig 48 } alarm4Delaysys OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm output delay in seconds " ::= { systemConfig 49 } alarm5Delaysys OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm output delay in seconds " ::= { systemConfig 50 } alarm6Delaysys OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm output delay in seconds " ::= { systemConfig 51 } alarm7Delaysys OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm output delay in seconds " ::= { systemConfig 52 } alarm8Delaysys OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm output delay in seconds " ::= { systemConfig 53 } alarm9Delaysys OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm output delay in seconds " ::= { systemConfig 54 } alarm10Delaysys OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm output delay in seconds " ::= { systemConfig 55 } ac1NONCsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - NO, 1 - NC " ::= { systemConfig 56 } ac2NONCsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - NO, 1 - NC " ::= { systemConfig 57 } dig1NONCsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - NO, 1 - NC " ::= { systemConfig 58 } dig2NONCsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - NO, 1 - NC " ::= { systemConfig 59 } dig3NONCsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - NO, 1 - NC " ::= { systemConfig 60 } dig2funcoverridesys OBJECT-TYPE SYNTAX INTEGER(0..2) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - Override, 1 - setpoint offset, 2 - mode X " ::= { systemConfig 61 } dig3funcoverridesys OBJECT-TYPE SYNTAX INTEGER(0..2) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - Override, 1 - setpoint offset, 2 - mode X " ::= { systemConfig 62 } dig2offsetsys OBJECT-TYPE SYNTAX INTEGER(-10..10) ACCESS read-write STATUS mandatory DESCRIPTION " Cooling setpoint offset " ::= { systemConfig 63 } dig3offsetsys OBJECT-TYPE SYNTAX INTEGER(-10..10) ACCESS read-write STATUS mandatory DESCRIPTION " Cooling setpoint offset " ::= { systemConfig 64 } dig2trigModesys OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - FC, 1 - Std, 2 - Ps, 3 - Acon " ::= { systemConfig 65 } dig3TrigModesys OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - FC, 1 - Std, 2 - Ps, 3 - Acon" ::= { systemConfig 66 } filterGuard1NONCsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - NO, 1 - NC " ::= { systemConfig 67 } filterGuard2NONCsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - NO, 1 - NC " ::= { systemConfig 68 } temprUnitsCFsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - Celcius, 1 - Fahrenheit " ::= { systemConfig 69 } languageEnglishsys OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION " 0 - Disable, 1 - Enable " ::= { systemConfig 70 } -- -- Controller-CC3000 : alarmConfig saveReloadConfAlm OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Discard modifications, 1 - Save Modifications. Alarm Mapping reloaded " ::= { alarmConfig 1 } alarm1mask OBJECT-TYPE SYNTAX INTEGER(0..33554432) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm drive 1 Mask [Can have multiple Alarm Errors]. Bit Position - Value - Alarm Drive State: 0 - Unselect, 1 - Select 1 - 1 - Voltage Low 2 - 2 - Voltage High 3 - 4 - Tempr Low 4 - 8 - Tempr Limit 1 5 - 16 - Tempr Limit 2 6 - 32 - Tempr Limit 3 7 - 64 - Humid. Low 8 - 128 - Humid. High 9 - 256 - Fltr Pressure 1 10 - 512 - Fltr Pressure 2 11 - 1024 - Fan 1 12 - 2048 - Fan 2 13 - 4096 - Onboard Sens 14 - 8192 - Room Sens 15 - 16384 - Hotspot Sens 16 - 32768 - Ambient 1 Sens 17 - 65536 - Ambient 2 Sens 18 - 131072 - Dig 1 I/P 19 - 262144 - Dig 2 I/P 20 - 524288 - Dig 3 I/P 21 - 1048576 - Filter I/P 1 22 - 2097152 - Filter I/P 2 23 - 4194304 - Network 24 - 8388608 - Int storage 25 - 16777216 - SD Card " ::= { alarmConfig 2 } alarm2mask OBJECT-TYPE SYNTAX INTEGER(0..33554432) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm drive 2 Mask [Can have multiple Alarm Errors]. Bit Position - Value - Alarm Drive State: 0 - Unselect, 1 - Select 1 - 1 - Voltage Low 2 - 2 - Voltage High 3 - 4 - Tempr Low 4 - 8 - Tempr Limit 1 5 - 16 - Tempr Limit 2 6 - 32 - Tempr Limit 3 7 - 64 - Humid. Low 8 - 128 - Humid. High 9 - 256 - Fltr Pressure 1 10 - 512 - Fltr Pressure 2 11 - 1024 - Fan 1 12 - 2048 - Fan 2 13 - 4096 - Onboard Sens 14 - 8192 - Room Sens 15 - 16384 - Hotspot Sens 16 - 32768 - Ambient 1 Sens 17 - 65536 - Ambient 2 Sens 18 - 131072 - Dig 1 I/P 19 - 262144 - Dig 2 I/P 20 - 524288 - Dig 3 I/P 21 - 1048576 - Filter I/P 1 22 - 2097152 - Filter I/P 2 23 - 4194304 - Network 24 - 8388608 - Int storage 25 - 16777216 - SD Card " ::= { alarmConfig 3 } alarm3mask OBJECT-TYPE SYNTAX INTEGER(0..25) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm drive 3 Select [Single Alarm Error]. Bit Position - Alarm Drive State: 0 - Unselect, 1-25 - Select 1 - Voltage Low 2 - Voltage High 3 - Tempr Low 4 - Tempr Limit 1 5 - Tempr Limit 2 6 - Tempr Limit 3 7 - Humid. Low 8 - Humid. High 9 - Fltr Pressure 1 10 - Fltr Pressure 2 11 - Fan 1 12 - Fan 2 13 - Onboard Sens 14 - Room Sens 15 - Hotspot Sens 16 - Ambient 1 Sens 17 - Ambient 2 Sens 18 - Dig 1 I/P 19 - Dig 2 I/P 20 - Dig 3 I/P 21 - Filter I/P 1 22 - Filter I/P 2 23 - Network 24 - Int storage 25 - SD Card " ::= { alarmConfig 4 } alarm4mask OBJECT-TYPE SYNTAX INTEGER(0..25) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm drive 4 Select [Single Alarm Error]. Bit Position - Alarm Drive State: 0 - Unselect, 1-25 - Select 1 - Voltage Low 2 - Voltage High 3 - Tempr Low 4 - Tempr Limit 1 5 - Tempr Limit 2 6 - Tempr Limit 3 7 - Humid. Low 8 - Humid. High 9 - Fltr Pressure 1 10 - Fltr Pressure 2 11 - Fan 1 12 - Fan 2 13 - Onboard Sens 14 - Room Sens 15 - Hotspot Sens 16 - Ambient 1 Sens 17 - Ambient 2 Sens 18 - Dig 1 I/P 19 - Dig 2 I/P 20 - Dig 3 I/P 21 - Filter I/P 1 22 - Filter I/P 2 23 - Network 24 - Int storage 25 - SD Card " ::= { alarmConfig 5 } alarm5mask OBJECT-TYPE SYNTAX INTEGER(0..25) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm drive 5 Select [Single Alarm Error]. Bit Position - Alarm Drive State: 0 - Unselect, 1-25 - Select 1 - Voltage Low 2 - Voltage High 3 - Tempr Low 4 - Tempr Limit 1 5 - Tempr Limit 2 6 - Tempr Limit 3 7 - Humid. Low 8 - Humid. High 9 - Fltr Pressure 1 10 - Fltr Pressure 2 11 - Fan 1 12 - Fan 2 13 - Onboard Sens 14 - Room Sens 15 - Hotspot Sens 16 - Ambient 1 Sens 17 - Ambient 2 Sens 18 - Dig 1 I/P 19 - Dig 2 I/P 20 - Dig 3 I/P 21 - Filter I/P 1 22 - Filter I/P 2 23 - Network 24 - Int storage 25 - SD Card " ::= { alarmConfig 6 } alarm6mask OBJECT-TYPE SYNTAX INTEGER(0..25) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm drive 6 Select [Single Alarm Error]. Bit Position - Alarm Drive State: 0 - Unselect, 1-25 - Select 1 - Voltage Low 2 - Voltage High 3 - Tempr Low 4 - Tempr Limit 1 5 - Tempr Limit 2 6 - Tempr Limit 3 7 - Humid. Low 8 - Humid. High 9 - Fltr Pressure 1 10 - Fltr Pressure 2 11 - Fan 1 12 - Fan 2 13 - Onboard Sens 14 - Room Sens 15 - Hotspot Sens 16 - Ambient 1 Sens 17 - Ambient 2 Sens 18 - Dig 1 I/P 19 - Dig 2 I/P 20 - Dig 3 I/P 21 - Filter I/P 1 22 - Filter I/P 2 23 - Network 24 - Int storage 25 - SD Card " ::= { alarmConfig 7 } alarm7mask OBJECT-TYPE SYNTAX INTEGER(0..25) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm drive 7 Select [Single Alarm Error]. Bit Position - Alarm Drive State: 0 - Unselect, 1-25 - Select 1 - Voltage Low 2 - Voltage High 3 - Tempr Low 4 - Tempr Limit 1 5 - Tempr Limit 2 6 - Tempr Limit 3 7 - Humid. Low 8 - Humid. High 9 - Fltr Pressure 1 10 - Fltr Pressure 2 11 - Fan 1 12 - Fan 2 13 - Onboard Sens 14 - Room Sens 15 - Hotspot Sens 16 - Ambient 1 Sens 17 - Ambient 2 Sens 18 - Dig 1 I/P 19 - Dig 2 I/P 20 - Dig 3 I/P 21 - Filter I/P 1 22 - Filter I/P 2 23 - Network 24 - Int storage 25 - SD Card " ::= { alarmConfig 8 } alarm8mask OBJECT-TYPE SYNTAX INTEGER(0..25) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm drive 8 Select [Single Alarm Error]. Bit Position - Alarm Drive State: 0 - Unselect, 1-25 - Select 1 - Voltage Low 2 - Voltage High 3 - Tempr Low 4 - Tempr Limit 1 5 - Tempr Limit 2 6 - Tempr Limit 3 7 - Humid. Low 8 - Humid. High 9 - Fltr Pressure 1 10 - Fltr Pressure 2 11 - Fan 1 12 - Fan 2 13 - Onboard Sens 14 - Room Sens 15 - Hotspot Sens 16 - Ambient 1 Sens 17 - Ambient 2 Sens 18 - Dig 1 I/P 19 - Dig 2 I/P 20 - Dig 3 I/P 21 - Filter I/P 1 22 - Filter I/P 2 23 - Network 24 - Int storage 25 - SD Card " ::= { alarmConfig 9 } alarm9mask OBJECT-TYPE SYNTAX INTEGER(0..25) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm drive 9 Select [Single Alarm Error]. Bit Position - Alarm Drive State: 0 - Unselect, 1-25 - Select 1 - Voltage Low 2 - Voltage High 3 - Tempr Low 4 - Tempr Limit 1 5 - Tempr Limit 2 6 - Tempr Limit 3 7 - Humid. Low 8 - Humid. High 9 - Fltr Pressure 1 10 - Fltr Pressure 2 11 - Fan 1 12 - Fan 2 13 - Onboard Sens 14 - Room Sens 15 - Hotspot Sens 16 - Ambient 1 Sens 17 - Ambient 2 Sens 18 - Dig 1 I/P 19 - Dig 2 I/P 20 - Dig 3 I/P 21 - Filter I/P 1 22 - Filter I/P 2 23 - Network 24 - Int storage 25 - SD Card " ::= { alarmConfig 10 } alarm10mask OBJECT-TYPE SYNTAX INTEGER(0..25) ACCESS read-write STATUS mandatory DESCRIPTION " Alarm drive 10 Select [Single Alarm Error]. Bit Position - Alarm Drive State: 0 - Unselect, 1-25 - Select 1 - Voltage Low 2 - Voltage High 3 - Tempr Low 4 - Tempr Limit 1 5 - Tempr Limit 2 6 - Tempr Limit 3 7 - Humid. Low 8 - Humid. High 9 - Fltr Pressure 1 10 - Fltr Pressure 2 11 - Fan 1 12 - Fan 2 13 - Onboard Sens 14 - Room Sens 15 - Hotspot Sens 16 - Ambient 1 Sens 17 - Ambient 2 Sens 18 - Dig 1 I/P 19 - Dig 2 I/P 20 - Dig 3 I/P 21 - Filter I/P 1 22 - Filter I/P 2 23 - Network 24 - Int storage 25 - SD Card " ::= { alarmConfig 11 } -- -- Controller-CC3000 : nightModeConfig saveReloadConfNm OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Discard modifications, 1 - Save Modifications. Configuration reloaded " ::= { nightModeConfig 1 } starttimeHournm OBJECT-TYPE SYNTAX INTEGER(0..24) ACCESS read-write STATUS mandatory DESCRIPTION " Night Mode Start time hour " ::= { nightModeConfig 2 } startTimeMinutesnm OBJECT-TYPE SYNTAX INTEGER(0..59) ACCESS read-write STATUS mandatory DESCRIPTION " Night Mode Start time minutes " ::= { nightModeConfig 3 } endTimeHournm OBJECT-TYPE SYNTAX INTEGER(0..24) ACCESS read-write STATUS mandatory DESCRIPTION " Night Mode End time hour " ::= { nightModeConfig 4 } endTimeMinutesnm OBJECT-TYPE SYNTAX INTEGER(0..59) ACCESS read-write STATUS mandatory DESCRIPTION " Night Mode End time minutes " ::= { nightModeConfig 5 } fanMaxRPMnm OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-write STATUS mandatory DESCRIPTION " % of max fan speed " ::= { nightModeConfig 6 } setPointOffsetnm OBJECT-TYPE SYNTAX INTEGER(-10..10) ACCESS read-write STATUS mandatory DESCRIPTION "Cooling setpoint offset " ::= { nightModeConfig 7 } coolingModenm OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Freecooling. 1 - Standard. 2 - Power save. 3 - Aircon. " ::= { nightModeConfig 8 } enablenm OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Disable. 1 - Enable. " ::= { nightModeConfig 9 } -- -- Controller-CC3000 : networkConfig saveReloadConfNW OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Discard modifications, 1 - Save Modifications. Configuration reloaded " ::= { networkConfig 1 } dhcpenable OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS read-write STATUS mandatory DESCRIPTION "0 - Static IP, 1 - Dynamic IP " ::= { networkConfig 2 } ipaddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "System IP Address" ::= { networkConfig 3 } subnetmask OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Sub-net Mask " ::= { networkConfig 4 } gatewayIPaddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Default Gateway IP Address" ::= { networkConfig 5 } ntpIPaddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "DNS IP Address" ::= { networkConfig 6 } snmpPort OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "SNMP Agent Port" ::= { networkConfig 7 } trapServer1IPaddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "SNMP TRAP manager 1 IP address" ::= { networkConfig 8 } trapServer1port OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "SNMP TRAP manager 1 Port Number" ::= { networkConfig 9 } trapServer2IPaddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "SNMP TRAP manager 2 IP address" ::= { networkConfig 10 } trapServer2port OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "SNMP TRAP manager 2 Port Number" ::= { networkConfig 11 } trapServer3IPaddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "SNMP TRAP manager 3 IP address" ::= { networkConfig 12 } trapServer3port OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "SNMP TRAP manager 3 Port Number" ::= { networkConfig 13 } snmpCommunity OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "SNMP Read/write Community string" ::= { networkConfig 14 } hostName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "System Netwrok Host name" ::= { networkConfig 15 } -- -- Controller-CC3000 : trapError errorNumber OBJECT-TYPE SYNTAX INTEGER { VoltageLow (1), VoltageHigh (2), TemprLow (3), TemprLimit1 (4), TemprLimit2 (5), TemprLimit3 (6), HumidLow (7), HumidHigh (8), FltrPressure1 (9), FltPressure2 (10), Fan1 (11), Fan2 (12), OnboardSens (13), RoomSens (14), HotspotSens (15), Ambient1Sens (16), Ambient2Sens (17), Dig1IP (18), Dig2IP (19), Dig3IP (20), FilterIP1 (21), FilterIP2 (22), Network (23), Intstorage (24), SDCard (25) } ACCESS not-accessible STATUS mandatory DESCRIPTION " Error Number corresponding to CC3000 controller Error." ::= { trapError 1 } status OBJECT-TYPE SYNTAX INTEGER { ALARMset (1), ALARMclear (0) } ACCESS not-accessible STATUS mandatory DESCRIPTION " Error Status Active/SET or Inactive/CLEAR." ::= { trapError 2 } value OBJECT-TYPE SYNTAX OCTET STRING ACCESS not-accessible STATUS mandatory DESCRIPTION " Value Corresponding to Error Occurance Instance." ::= { trapError 3 } info OBJECT-TYPE SYNTAX OCTET STRING ACCESS not-accessible STATUS mandatory DESCRIPTION " Description of Current Error." ::= { trapError 4 } cc3000Trap TRAP-TYPE ENTERPRISE danthermCooling VARIABLES {hostName, errorNumber, status, value, info } DESCRIPTION "Trap From CC300 Controller. Contains TRAP information " REFERENCE "None" ::= 1 END