-- -- dasan-notification.mib -- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88 -- Thursday, December 09, 2010 at 18:13:13 -- -- dasan-notification.mib -- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88 -- Thursday, December 09, 2010 at 17:43:42 -- -- dasan-notification.mib -- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88 -- Thursday, December 09, 2010 at 17:25:10 -- -- ***************************************************************** -- DASAN-NOTIFICATION.mib: Dasan Enterprise Notifications -- -- Copyright (c) 2001 by Dasan Co., Ltd. -- All rights reserved. -- -- ***************************************************************** -- DASAN-NOTIFICATION DEFINITIONS ::= BEGIN IMPORTS dsSubnetConfName FROM DASAN-DHCP-MIB dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonPortIndex, dsPonDirection, dsPonState, dsPonCount, dsPonQueueIndex FROM DASAN-GEPON-MIB dasanEvents FROM DASAN-SMI dsFreeMem, dsSystemUpgradePath, dsSystemUpgradeStorage, dsPortModuleIndex, dsPortPortIndex, dsPortInstallStatus, dsTemperatureStatus, dsPowerIndex, dsPowerstatus, dsFanIndex, dsFanstatus, dsUserMacAddress1, dsUserMacAddress2, dsUserMacAddress3, dsUserMacAddress4, dsSwitchAtNetAddress, dsSwitchAtMacAddress, dsSwitchAtVID FROM DASAN-SWITCH-MIB dsUserLoginName, dsUserLoginIpAddress FROM DASAN-USER-MANAGEMENT-MIB sleY1731MegIndex, sleY1731MEgRaspWestPortStatus, sleY1731MEgRaspEastPortStatus FROM SLE-FAULTMGMT-MIB ifIndex FROM IF-MIB sysDescr, sysUpTime FROM SNMPv2-MIB NOTIFICATION-TYPE FROM SNMPv2-SMI; -- -- Node definitions -- -- Node definitions -- -- Node definitions -- -- Dasan Enterprise-Specific TRAP define -- updated by dhlee@da-san.com 2003/03/07 -- moved from DASAN-SWITCH-MIB.my -- updated by dhl@da-san.com 2004/06/10 -- -- 1.3.6.1.4.1.6296.0.1 portInstalled NOTIFICATION-TYPE OBJECTS { ifIndex, dsPortInstallStatus } STATUS current DESCRIPTION "portI0nstalled trap send when portInstallStatus is enabled." ::= { dasanEvents 1 } -- 1.3.6.1.4.1.6296.0.2 portRemoved NOTIFICATION-TYPE OBJECTS { ifIndex, dsPortInstallStatus } STATUS current DESCRIPTION "portInstalled trap send when portInstallStatus is disabled." ::= { dasanEvents 2 } -- 1.3.6.1.4.1.6296.0.3 powerOk NOTIFICATION-TYPE OBJECTS { dsPowerIndex, dsPowerstatus } STATUS current DESCRIPTION "Power status OK trap when powerStatus change from disable to enable." ::= { dasanEvents 3 } -- 1.3.6.1.4.1.6296.0.4 powerFail NOTIFICATION-TYPE OBJECTS { dsPowerIndex, dsPowerstatus } STATUS current DESCRIPTION "Power status fail trap when powerStatus change from enable to disable." ::= { dasanEvents 4 } -- 1.3.6.1.4.1.6296.0.5 fanOk NOTIFICATION-TYPE OBJECTS { dsFanIndex, dsFanstatus } STATUS current DESCRIPTION "Fan status OK trap when fanStatus change from disable to enable." ::= { dasanEvents 5 } -- 1.3.6.1.4.1.6296.0.6 fanFail NOTIFICATION-TYPE OBJECTS { dsFanIndex, dsFanstatus } STATUS current DESCRIPTION "Fan status fail trap when fanStatus change from enable to disable." ::= { dasanEvents 6 } -- 1.3.6.1.4.1.6296.0.7 powerInstalled NOTIFICATION-TYPE OBJECTS { dsPowerIndex } STATUS current DESCRIPTION "Power Installed trap when power was installed." ::= { dasanEvents 7 } -- 1.3.6.1.4.1.6296.0.8 powerRemoved NOTIFICATION-TYPE OBJECTS { dsPowerIndex } STATUS current DESCRIPTION "Power removed trap when power was removed." ::= { dasanEvents 8 } -- 1.3.6.1.4.1.6296.0.9 fanInstalled NOTIFICATION-TYPE OBJECTS { dsFanIndex } STATUS current DESCRIPTION "Fan Installed trap when fan was installed." ::= { dasanEvents 9 } -- 1.3.6.1.4.1.6296.0.10 fanRemoved NOTIFICATION-TYPE OBJECTS { dsFanIndex } STATUS current DESCRIPTION "Fan removed trap when fan was removed." ::= { dasanEvents 10 } -- 1.3.6.1.4.1.6296.0.11 bcastOver NOTIFICATION-TYPE OBJECTS { sysDescr } STATUS current DESCRIPTION "Broadcast packet over trap when Rx broadcast packet is over the given limit." ::= { dasanEvents 11 } -- 1.3.6.1.4.1.6296.0.12 cpuLoadOverThreshold NOTIFICATION-TYPE OBJECTS { sysDescr } STATUS current DESCRIPTION "The cpuLoadOverThreshold trap is sent when cpuLoad is over the given limit." ::= { dasanEvents 12 } -- 1.3.6.1.4.1.6296.0.13 cpuLoadFallThreshold NOTIFICATION-TYPE OBJECTS { sysDescr } STATUS current DESCRIPTION "The cpuLoadfallThreshold trap is sent when cpuLoad fall under the given limit." ::= { dasanEvents 13 } -- 1.3.6.1.4.1.6296.0.14 dhcpLeaseShortage NOTIFICATION-TYPE OBJECTS { sysDescr, dsSubnetConfName } STATUS current DESCRIPTION "DHCP User IP pool shortage when User's DHCPDISCOVER message arrive." ::= { dasanEvents 14 } -- 1.3.6.1.4.1.6296.0.15 portOverThreshold NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "Port traffic over HighThreshold trap when port traffic is over the given limit." ::= { dasanEvents 15 } -- 1.3.6.1.4.1.6296.0.16 portFallThreshold NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "Port traffic fall under HighThreshold trap when port traffic falls below the given limit." ::= { dasanEvents 16 } -- 1.3.6.1.4.1.6296.0.17 temperatureOverThreshold NOTIFICATION-TYPE OBJECTS { dsTemperatureStatus} STATUS current DESCRIPTION "TemperatureOverThreshold Trap is sent when temperature is over the certain threshold." ::= { dasanEvents 17 } -- 1.3.6.1.4.1.6296.0.18 systemRestart NOTIFICATION-TYPE OBJECTS { sysDescr, sleAutoResetBootReason } STATUS current DESCRIPTION "SystemRestart Trap is sent when system is restarted by user. sleAutoResetBootReason is only used for auto-reset" ::= { dasanEvents 18 } -- 1.3.6.1.4.1.6296.0.19 mfgdBlocked NOTIFICATION-TYPE OBJECTS { dsSwitchAtMacAddress, dsSwitchAtNetAddress, dsSwitchAtVID } STATUS current DESCRIPTION "mfgdblocked Trap is sent when a certain mac address is denied by mac-flood-guard mechanism." ::= { dasanEvents 19 } -- 1.3.6.1.4.1.6296.0.20 mfgdReleased NOTIFICATION-TYPE OBJECTS { dsSwitchAtMacAddress, dsSwitchAtNetAddress, dsSwitchAtVID } STATUS current DESCRIPTION "mfgdReleased Trap is sent when a certain mac address is permitted again by mac-flood-guard mechanism." ::= { dasanEvents 20 } -- 1.3.6.1.4.1.6296.0.21 ipConflict NOTIFICATION-TYPE OBJECTS { dsSwitchAtNetAddress, dsSwitchAtMacAddress } STATUS current DESCRIPTION "ipConflict Trap is sent when a certain IP address is shared among different users." ::= { dasanEvents 21 } -- 1.3.6.1.4.1.6296.0.22 dhcpIllegalEntry NOTIFICATION-TYPE OBJECTS { dsSwitchAtNetAddress, dsSwitchAtMacAddress, ifIndex } STATUS current DESCRIPTION "dhcpIllegalEntry trap is sent when illegal dhcp user is found." ::= { dasanEvents 22 } -- 1.3.6.1.4.1.6296.0.23 optionModuleInstalled NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "optionModuleInstalled Trap is sent when option Module was installed." ::= { dasanEvents 23 } -- 1.3.6.1.4.1.6296.0.24 optionModuleRemoved NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "optionModuleRemoved Trap is sent when option Module was removed." ::= { dasanEvents 24 } -- 1.3.6.1.4.1.6296.0.25 memoryOverThreshold NOTIFICATION-TYPE OBJECTS { sysDescr, dsFreeMem, sleSlotSystemIndex } STATUS current DESCRIPTION "MemoryOverThreshold trap is sent when used memory size is over the given limit and free memory size falls below the given limit." ::= { dasanEvents 25 } -- 1.3.6.1.4.1.6296.0.26 memoryFallThreshold NOTIFICATION-TYPE OBJECTS { sysDescr, dsFreeMem, sleSlotSystemIndex } STATUS current DESCRIPTION "MemoryFallThreshold trap is sent when free memory size is over the given limit." ::= { dasanEvents 26 } -- 1.3.6.1.4.1.6296.0.27 slotInstalled NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "slotInstalledTrap Trap is sent when Board was installed." ::= { dasanEvents 27 } -- 1.3.6.1.4.1.6296.0.28 slotRemoved NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "slotRemovedTrap Trap is sent when Board was removed." ::= { dasanEvents 28 } -- 1.3.6.1.4.1.6296.0.29 slotStateChange NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "slotStateChangeTrap Trap is sent when Board State change." ::= { dasanEvents 29 } -- 1.3.6.1.4.1.6296.0.30 portCRCOverThreshold NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "portCRCOverThreshold Trap is sent when the CRC count of port over threshold." ::= { dasanEvents 30 } -- 1.3.6.1.4.1.6296.0.31 portCRCFallThreshold NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "portCRCOverThreshold Trap is sent when the CRC count of port fall threshold." ::= { dasanEvents 31 } -- Newly Add traps related to temperature. -- -- 1.3.6.1.4.1.6296.0.32 temperatureHighOverThreshold NOTIFICATION-TYPE OBJECTS { dsTemperatureStatus, sleSlotSystemIndex } STATUS current DESCRIPTION "The temperatureHighOverThreshold Trap is sent when temperature is over the high-threshold." ::= { dasanEvents 32 } -- 1.3.6.1.4.1.6296.0.33 temperatureHighFallThreshold NOTIFICATION-TYPE OBJECTS { dsTemperatureStatus, sleSlotSystemIndex } STATUS current DESCRIPTION "The temperatureHighFallThreshold Trap is sent when temperature fall the high-threshold." ::= { dasanEvents 33 } -- 1.3.6.1.4.1.6296.0.34 temperatureLowOverThreshold NOTIFICATION-TYPE OBJECTS { dsTemperatureStatus, sleSlotSystemIndex } STATUS current DESCRIPTION "The temperatureLowOverThreshold Trap is sent when 1st temperature is over the low-threshold." ::= { dasanEvents 34 } -- 1.3.6.1.4.1.6296.0.35 temperatureLowFallThreshold NOTIFICATION-TYPE OBJECTS { dsTemperatureStatus, sleSlotSystemIndex } STATUS current DESCRIPTION "The temperatureLowFallThreshold Trap is sent when temperature fall under the low-threshold." ::= { dasanEvents 35 } -- 1.3.6.1.4.1.6296.0.36 userLogIn NOTIFICATION-TYPE OBJECTS { dsUserLoginName, dsUserLoginIpAddress } STATUS current DESCRIPTION "The user-login trap is sent when user login." ::= { dasanEvents 36 } -- 1.3.6.1.4.1.6296.0.37 userLogOut NOTIFICATION-TYPE OBJECTS { dsUserLoginName, dsUserLoginIpAddress } STATUS current DESCRIPTION "The user-logout trap is sent when user logout." ::= { dasanEvents 37 } -- 1.3.6.1.4.1.6296.0.38 restoreFactory NOTIFICATION-TYPE OBJECTS { sysDescr } STATUS current DESCRIPTION "The restoreFactory trap is sent when user initialize as factory defaults." ::= { dasanEvents 38 } -- 1.3.6.1.4.1.6296.0.39 cpuLoadHighOverThreshold NOTIFICATION-TYPE OBJECTS { sysDescr, sleSlotSystemIndex, sleSlotSystemCPULoadCurrent, sleSlotSystemCPULoadHighThreshold} STATUS current DESCRIPTION "The cpuloadHighOverThreshold Trap is sent when temperature is over the high-threshold." ::= { dasanEvents 39 } -- 1.3.6.1.4.1.6296.0.40 cpuLoadHighFallThreshold NOTIFICATION-TYPE OBJECTS { sysDescr, sleSlotSystemIndex, sleSlotSystemCPULoadCurrent, sleSlotSystemCPULoadHighThreshold} STATUS current DESCRIPTION "The cpuloadHighFallThreshold Trap is sent when temperature fall the high-threshold." ::= { dasanEvents 40 } -- 1.3.6.1.4.1.6296.0.41 cpuLoadLowOverThreshold NOTIFICATION-TYPE OBJECTS { sysDescr, sleSlotSystemIndex, sleSlotSystemCPULoadCurrent, sleSlotSystemCPULoadLowThreshold} STATUS current DESCRIPTION "The cpuloadLowOverThreshold Trap is sent when 1st temperature is over the low-threshold." ::= { dasanEvents 41 } -- 1.3.6.1.4.1.6296.0.42 cpuLoadLowFallThreshold NOTIFICATION-TYPE OBJECTS { sysDescr, sleSlotSystemIndex, sleSlotSystemCPULoadCurrent, sleSlotSystemCPULoadLowThreshold} STATUS current DESCRIPTION "The cpuloadLowFallThreshold Trap is sent when temperature fall under the low-threshold." ::= { dasanEvents 42 } -- skip 43 for dsIgmpSnooping Notification -- igmpSnoopingChanged NOTIFICATION-TYPE -- ::= {dasanEvents 43 } -- 1.3.6.1.4.1.6296.0.44 dsSystemUpgradeChanged NOTIFICATION-TYPE OBJECTS { sysDescr } STATUS current DESCRIPTION "System NOS Upgrade status" ::= { dasanEvents 44 } -- 1.3.6.1.4.1.6296.0.45 interfaceOperDown NOTIFICATION-TYPE OBJECTS { ifIndex, ifOperStatus, sleSlotSystemIndex } STATUS current DESCRIPTION "This trap indicates the interface oper down." ::= { dasanEvents 45 } -- 1.3.6.1.4.1.6296.0.46 interfaceOperUp NOTIFICATION-TYPE OBJECTS { ifIndex, ifOperStatus, sleSlotSystemIndex } STATUS current DESCRIPTION "This trap indicates the interface poer up." ::= { dasanEvents 46 } -- 1.3.6.1.4.1.6296.0.47 macLearnOverMax NOTIFICATION-TYPE OBJECTS { sysDescr } STATUS current DESCRIPTION "This trap indicates the count of L2 mac is over the max." ::= { dasanEvents 47 } -- 1.3.6.1.4.1.6296.0.48 macLearnOverMaxCleared NOTIFICATION-TYPE OBJECTS { sysDescr } STATUS current DESCRIPTION "This trap indicates the count of L2 mac is over the max is cleared" ::= { dasanEvents 48 } -- 1.3.6.1.4.1.6296.0.49 interfaceMacLearnOverMax NOTIFICATION-TYPE OBJECTS { sysDescr, ifindex } STATUS current DESCRIPTION "This trap indicates the count of interface's L2 mac is over the max." ::= { dasanEvents 49 } -- 1.3.6.1.4.1.6296.0.50 interfaceMacLearnOverMaxCleared NOTIFICATION-TYPE OBJECTS { sysDescr, ifindex } STATUS current DESCRIPTION "This trap indicates the count of interface's L2 mac is over the max is cleared" ::= { dasanEvents 50 } -- 1.3.6.1.4.1.6296.0.51 adslAtucPerfLofsThresh NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Loss of Framing threshold reached(ATUC)." ::= { dasanEvents 51 } -- 1.3.6.1.4.1.6296.0.52 adslAtucPerfLossThresh NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Loss of signal threshold reached(ATUC)." ::= { dasanEvents 52 } -- 1.3.6.1.4.1.6296.0.53 adslAtucPerfLprsThresh NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Loss of power threshold reached (ATUC)." ::= { dasanEvents 53 } -- 1.3.6.1.4.1.6296.0.54 adslAtucPerfESsThresh NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Errored Seconds threshold reached (ATUC)." ::= { dasanEvents 54 } -- 1.3.6.1.4.1.6296.0.55 adslAtucRateChange NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Changed atuc rate." ::= { dasanEvents 55 } -- 1.3.6.1.4.1.6296.0.56 adslAtucPerfLolsThresh NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Loss of Link threshold reached (ATUC)." ::= { dasanEvents 56 } -- 1.3.6.1.4.1.6296.0.61 adslAturPerfLofsThresh NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Loss of Framing threshold reached(ATUR)." ::= { dasanEvents 61 } -- 1.3.6.1.4.1.6296.0.62 adslAturPerfLossThresh NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Loss of signal threshold reached(ATUR)." ::= { dasanEvents 62 } -- 1.3.6.1.4.1.6296.0.63 adslAturPerfLprsThresh NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Loss of power threshold reached (ATUR)." ::= { dasanEvents 63 } -- 1.3.6.1.4.1.6296.0.64 adslAturPerfESsThresh NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Errored Seconds threshold reached (ATUR)." ::= { dasanEvents 64 } -- 1.3.6.1.4.1.6296.0.65 vdslCPEChangeInfoTrap NOTIFICATION-TYPE OBJECTS { sysDescr, ipAdEntAddr, dsVdslPortIndex, vdslPhysInvSerialNumber, dsUserMacAddress1, dsUserMacAddress2, dsUserMacAddress3, dsUserMacAddress4 } STATUS current DESCRIPTION "Trap is sent with CPE Serial No., Mac Address of CPE, after CPE serial change. " ::= { dasanEvents 65 } -- 1.3.6.1.4.1.6296.0.66 vdslArulePacketDropTrap NOTIFICATION-TYPE OBJECTS { sysUpTime } STATUS current DESCRIPTION "Packet Dropped by arule . " ::= { dasanEvents 66 } -- 1.3.6.1.4.1.6296.0.69 portMododuleInstall NOTIFICATION-TYPE OBJECTS { ifindex } STATUS current DESCRIPTION "port module install" ::= { dasanEvents 69 } -- 1.3.6.1.4.1.6296.0.70 portMododuleRemove NOTIFICATION-TYPE OBJECTS { ifindex } STATUS current DESCRIPTION "port module remove" ::= { dasanEvents 70 } -- flood-guard (CPU|SYSTEM) -- -- 1.3.6.1.4.1.6296.0.71 cfgdBlocked NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "Cfgdblocked Trap is sent when a certain port is blocked by cpu-flood-guard mechanism." ::= { dasanEvents 71 } -- 1.3.6.1.4.1.6296.0.72 cfgdReleased NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "CfgdReleased Trap is sent when a certain port is non-blocked by cpu-flood-guard mechanism." ::= { dasanEvents 72 } -- 1.3.6.1.4.1.6296.0.73 cfgdOverThreshold NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "CfgdReleased Trap is sent when a certain port is over threshold by cpu-flood-guard mechanism." ::= { dasanEvents 73 } -- 1.3.6.1.4.1.6296.0.74 cfgdUnderThreshold NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "CfgdReleased Trap is sent when a certain port is under threshold by cpu-flood-guard mechanism." ::= { dasanEvents 74 } -- 1.3.6.1.4.1.6296.0.75 sfgdBlocked NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "Sfgdblocked Trap is sent when a certain port is blocked by system-flood-guard mechanism." ::= { dasanEvents 75 } -- 1.3.6.1.4.1.6296.0.76 sfgdReleased NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "SfgdReleased Trap is sent when a certain port is non-blocked by system-flood-guard mechanism." ::= { dasanEvents 76 } -- 1.3.6.1.4.1.6296.0.77 sfgdOverThreshold NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "SfgdReleased Trap is sent when a certain port is over threshold by system-flood-guard mechanism." ::= { dasanEvents 77 } -- 1.3.6.1.4.1.6296.0.78 sfgdUnderThreshold NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "SfgdReleased Trap is sent when a certain port is under threshold by system-flood-guard mechanism." ::= { dasanEvents 78 } -- 1.3.6.1.4.1.6296.0.79 ppsControlBlocked NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "PpsControlblocked Trap is sent when a certain port is blocked by PPS-Control mechanism." ::= { dasanEvents 79 } -- 1.3.6.1.4.1.6296.0.80 ppsControlReleased NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "PpsControlReleased Trap is sent when a certain port is non-blocked by PPS-Control mechanism." ::= { dasanEvents 80 } -- 1.3.6.1.4.1.6296.0.81 ppsControlOverThreshold NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "PpsControlReleased Trap is sent when a certain port is over threshold by PPS-Control mechanism." ::= { dasanEvents 81 } -- 1.3.6.1.4.1.6296.0.82 ppsControlUnderThreshold NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "PpsControlReleased Trap is sent when a certain port is under threshold by PPS-Control mechanism." ::= { dasanEvents 82 } -- remote upgrade -- -- 1.3.6.1.4.1.6296.0.83 nosRemoteUpgradeRequest NOTIFICATION-TYPE OBJECTS { sysDescr, dsSystemUpgradePath, dsSystemUpgradeStorage } STATUS current DESCRIPTION "This trap indicates that the system received nos-remote-upgrade command." ::= { dasanEvents 83 } -- 1.3.6.1.4.1.6296.0.84 nosRemoteUpgradeSuccess NOTIFICATION-TYPE OBJECTS { sysDescr, dsSystemUpgradePath, dsSystemUpgradeStorage } STATUS current DESCRIPTION "This trap indicates that the NOS succeeded to upgrade NOS." ::= { dasanEvents 84 } -- 1.3.6.1.4.1.6296.0.85 nosRemoteUpgradeFailAbort NOTIFICATION-TYPE OBJECTS { sysDescr, dsSystemUpgradePath, dsSystemUpgradeStorage } STATUS current DESCRIPTION "This trap indicates that the system failed to upgrade NOS by user interrupt" ::= { dasanEvents 85 } -- 1.3.6.1.4.1.6296.0.86 nosRemoteUpgradeFailHeaderError NOTIFICATION-TYPE OBJECTS { sysDescr, dsSystemUpgradePath, dsSystemUpgradeStorage } STATUS current DESCRIPTION "This trap indicates that the system failed to upgrade NOS, for NOS header-error." ::= { dasanEvents 86 } -- 1.3.6.1.4.1.6296.0.87 nosRemoteUpgradeFailDownloadError NOTIFICATION-TYPE OBJECTS { sysDescr, dsSystemUpgradePath, dsSystemUpgradeStorage } STATUS current DESCRIPTION "This trap indicates that the system failed to upgrade NOS, for NOS checksum-error" ::= { dasanEvents 87 } -- 1.3.6.1.4.1.6296.0.88 nosRemoteUpgradeFailFlashError NOTIFICATION-TYPE OBJECTS { sysDescr, dsSystemUpgradePath, dsSystemUpgradeStorage } STATUS current DESCRIPTION "This trap indicates that the system failed to upgrade NOS, for flash operation" ::= { dasanEvents 88 } -- 1.3.6.1.4.1.6296.0.89 nosRemoteUpgradeStart NOTIFICATION-TYPE OBJECTS { sysDescr, dsSystemUpgradePath, dsSystemUpgradeStorage } STATUS current DESCRIPTION "This trap indicates that the upgrade NOS process was started." ::= { dasanEvents 89 } -- Dying gasp for power fault -- 1.3.6.1.4.1.6296.0.90 systemDyingGasp NOTIFICATION-TYPE OBJECTS { sysDescr } STATUS current DESCRIPTION "This trap indicates that Dying-gasp for power fault." ::= { dasanEvents 90 } -- Attack-Guard -- 1.3.6.1.4.1.6296.0.91 attackGuardBlock NOTIFICATION-TYPE OBJECTS { dsPortModuleIndex, dsPortPortIndex } STATUS current DESCRIPTION "This trap indicates that some port is blocked by attack-guard." ::= { dasanEvents 91 } -- 1.3.6.1.4.1.6296.0.92 attackGuardUnBlock NOTIFICATION-TYPE OBJECTS { dsPortModuleIndex, dsPortPortIndex } STATUS current DESCRIPTION "This trap indicates that some port is unblocked by attack-guard." ::= { dasanEvents 92 } -- 1.3.6.1.4.1.6296.0.93 fanPeriodicFault NOTIFICATION-TYPE OBJECTS { dsFanIndex, dsFanstatus } STATUS current DESCRIPTION "This trap indicates the fan status is fault in some period." ::= { dasanEvents 93 } -- 1.3.6.1.4.1.6296.0.94 remoteOamDyingGasp NOTIFICATION-TYPE OBJECTS { ifindex } STATUS current DESCRIPTION "This trap indicates the remote oam entity is in dying-gasp ." ::= { dasanEvents 94 } -- 1.3.6.1.4.1.6296.0.95 remoteOamDyingGaspRestoration NOTIFICATION-TYPE OBJECTS { ifindex } STATUS current DESCRIPTION "This trap indicates the remote oam entity is restored." ::= { dasanEvents 95 } -- 1.3.6.1.4.1.6296.0.96 arpInspectInvalid NOTIFICATION-TYPE OBJECTS { sleArpInspectInvalidLogReason, sleArpInspectInvalidLogSamePktCnt, sleArpInspectInvalidLogOpcode, sleArpInspectInvalidLogPortNumber, sleArpInspectInvalidLogVlanId, sleArpInspectInvalidLogSrcMacAddr, sleArpInspectInvalidLogSrcIpAddr, sleArpInspectInvalidLogDstMacAddr, sleArpInspectInvalidLogDstIpAddr, sleArpInspectInvalidLogLastRecvTime } STATUS current DESCRIPTION "This trap indicates the ARP inspection is invalided." ::= { dasanEvents 96 } -- 1.3.6.1.4.1.6296.0.97 systemSwitchover NOTIFICATION-TYPE OBJECTS { sysDescr } STATUS current DESCRIPTION "This trap indicates the system is switchover." ::= { dasanEvents 97 } -- 1.3.6.1.4.1.6296.0.98 boardChangeState NOTIFICATION-TYPE OBJECTS { sleRedActiveBoard, sleRedActivePrevState, sleRedActiveCurrState } STATUS current DESCRIPTION "This trap indicates the board state is changed." ::= { dasanEvents 98 } -- 1.3.6.1.4.1.6296.0.99 redConfigurationMisMatch NOTIFICATION-TYPE OBJECTS {sysDescr} STATUS current DESCRIPTION "Configurations of Active and Standby SFU are different." ::= { dasanEvents 99} -- 100, 101 reserved as SLE -- -- 1.3.6.1.4.1.6296.0.105 clockModuleInstalled NOTIFICATION-TYPE OBJECTS { sleClockModuleIndex, sleClockModuleBoardId, sleClockModuleInstallStatus } STATUS current DESCRIPTION "clockModuleInstalled trap send when sleClockModuleInstallStatus is installed." ::= { dasanEvents 105 } -- 1.3.6.1.4.1.6296.0.106 clockModuleRemoved NOTIFICATION-TYPE OBJECTS { sleClockModuleIndex, sleClockModuleBoardId, sleClockModuleInstallStatus } STATUS current DESCRIPTION "clockModuleRemoved trap send when sleClockModuleInstallStatus is removed." ::= { dasanEvents 106 } -- 1.3.6.1.4.1.6296.0.107 clockModuleInitOk NOTIFICATION-TYPE OBJECTS { sleClockModuleIndex, sleClockModuleBoardId, sleClockModuleInitStatus } STATUS current DESCRIPTION "clockModuleInitOk trap send when sleClockModuleInitStatus is ok." ::= { dasanEvents 107 } -- 1.3.6.1.4.1.6296.0.108 clockModuleInitFail NOTIFICATION-TYPE OBJECTS { sleClockModuleIndex, sleClockModuleBoardId, sleClockModuleInitStatus } STATUS current DESCRIPTION "clockModuleInitFail trap send when sleClockModuleInitStatus is failure." ::= { dasanEvents 108 } -- 1.3.6.1.4.1.6296.0.109 interfaceAdminUp NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr, ifAdminStatus } STATUS current DESCRIPTION "This trap indicates the interface admin up." ::= { dasanEvents 109 } -- 1.3.6.1.4.1.6296.0.110 interfaceAdminDown NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr, ifAdminStatus } STATUS current DESCRIPTION "This trap indicates the interface admin down." ::= { dasanEvents 110 } -- 1.3.6.1.4.1.6296.0.111 powerMonEventDetected NOTIFICATION-TYPE OBJECTS { sleSlotPowerMonIndex, sleSlotPowerMonStatus } STATUS current DESCRIPTION "This trap indicates the power monitoring detects voltage change of slot." ::= { dasanEvents 111 } -- 1.3.6.1.4.1.6296.0.112 ntpConnectionFail NOTIFICATION-TYPE OBJECTS { sleNTPServerName } STATUS current DESCRIPTION "This trap indicates the ntp connection is lost." ::= { dasanEvents 112 } -- 1.3.6.1.4.1.6296.0.113 fanSpeedFallUnderThreshold NOTIFICATION-TYPE OBJECTS { sleFanUnitIndex, sleFanUnitSpeed } STATUS current DESCRIPTION "This trap indicates the fan speed is under the threshold." ::= { dasanEvents 113 } -- 1.3.6.1.4.1.6296.0.114 fanSpeedRisingOverThreshold NOTIFICATION-TYPE OBJECTS { sleFanUnitIndex, sleFanUnitSpeed } STATUS current DESCRIPTION "This trap indicates the fan speed is over the threshold." ::= { dasanEvents 114 } -- 1.3.6.1.4.1.6296.0.115 userLoginFail NOTIFICATION-TYPE OBJECTS { dsUserLoginName, dsUserLoginIpAddress } STATUS current DESCRIPTION "This trap indicates the user fail to login." ::= { dasanEvents 115 } -- 1.3.6.1.4.1.6296.0.116 bfdSessionStateChanged NOTIFICATION-TYPE OBJECTS { ifindex, sleBFDSessionNeighAddrType, sleBFDSessionNeighAddrValue, sleBFDSessionStatus } STATUS current DESCRIPTION "This trap indicates that BFD session state is changed." ::= { dasanEvents 116 } clockModuleOPModeChanged NOTIFICATION-TYPE OBJECTS { sleClockModuleIndex, sleClockModuleOPMode, sleSlotSystemIndex } STATUS current DESCRIPTION "This trap indicate that slot Operation mode is changed." ::= { dasanEvents 117 } clockModuleRefrencesChanged NOTIFICATION-TYPE OBJECTS { sleClockModuleIndex, sleSlotSystemIndex } STATUS current DESCRIPTION "This trap indicate that slot reference ntr is changed." ::= { dasanEvents 118 } -- 1.3.6.1.4.1.6296.0.119 portOperUp NOTIFICATION-TYPE OBJECTS { sleEthernetPortSlotIndex,sleEthernetPortSlotPortIndex } STATUS current DESCRIPTION "This trap indicate that port operation is up." ::= { dasanEvents 119 } -- 1.3.6.1.4.1.6296.0.120 portOperDown NOTIFICATION-TYPE OBJECTS { sleEthernetPortSlotIndex,sleEthernetPortSlotPortIndex } STATUS current DESCRIPTION "This trap indicate that port operation is down" ::= { dasanEvents 120 } -- 1.3.6.1.4.1.6296.0.121 portRxOverThreshold NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "Port Rx traffic over HighThreshold trap when port traffic is over the given limit." ::= { dasanEvents 121 } -- 1.3.6.1.4.1.6296.0.122 portRxFallThreshold NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "Port Rx traffic fall under HighThreshold trap when port traffic falls below the given limit." ::= { dasanEvents 122 } -- 1.3.6.1.4.1.6296.0.123 portTxOverThreshold NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "Port Tx traffic over HighThreshold trap when port traffic is over the given limit." ::= { dasanEvents 123 } -- 1.3.6.1.4.1.6296.0.124 portTxFallThreshold NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "Port Tx traffic fall under HighThreshold trap when port traffic falls below the given limit." ::= { dasanEvents 124 } clockModuleInSrcStatusChanged NOTIFICATION-TYPE OBJECTS { sleClockModuleIndex, sleClockInfoInSrcType, sleClockInfoInSrcStatus } STATUS current DESCRIPTION "This trap indicate that module status is changed." ::= { dasanEvents 125 } clockModuleInSrcAISStatusChanged NOTIFICATION-TYPE OBJECTS { sleClockModuleIndex, sleClockInfoInSrcType, sleClockInfoInSrcAISStatus } STATUS current DESCRIPTION "This trap indicate that AIS status is changed." ::= { dasanEvents 126 } clockModuleInSrcLoSStatusChaged NOTIFICATION-TYPE OBJECTS { sleClockModuleIndex, sleClockInfoInSrcType, sleClockInfoInSrcLoSStatus } STATUS current DESCRIPTION "This trap indicate that LOS status is changed." ::= { dasanEvents 127 } clockModuleInSrcLDSCStatus NOTIFICATION-TYPE OBJECTS { sleClockModuleIndex, sleClockInfoInSrcType, sleClockInfoInSrcLoSStatus } STATUS current DESCRIPTION "This trap indicate that LDSC status is changed." ::= { dasanEvents 128 } clockModuleInSrcNtrClockChanged NOTIFICATION-TYPE OBJECTS { sleClockModuleIndex, sleClockInfoInSrcType, sleClockInfoInSrcNtrClockType } STATUS current DESCRIPTION "This trap indicate that NTR is changed." ::= { dasanEvents 129 } reloadMateSFU NOTIFICATION-TYPE OBJECTS { sleSlotSystemIndex } STATUS current DESCRIPTION "This trap indicate that reload mate SFU." ::= { dasanEvents 130 } processDown NOTIFICATION-TYPE OBJECTS { sleSlotSystemIndex, sleProcessID } STATUS current DESCRIPTION "This trap indicate that certain process is crashed and restarted." ::= { dasanEvents 131 } processTimeout NOTIFICATION-TYPE OBJECTS { sleSlotSystemIndex, sleProcessID } STATUS current DESCRIPTION "This trap indicate that certain process is timeout." ::= { dasanEvents 132 } sdcardInstalled NOTIFICATION-TYPE OBJECTS { sleSlotSystemIndex } STATUS current DESCRIPTION "This trap indicate that SD card is installed." ::= { dasanEvents 133 } sdcardRemoved NOTIFICATION-TYPE OBJECTS { sleSlotSystemIndex } STATUS current DESCRIPTION "This trap indicate that SD card is removed." ::= { dasanEvents 134 } bootedNonDefaultOS NOTIFICATION-TYPE OBJECTS { sleSystemDefaultOS, sleSystemRunningOS, sleSlotSystemIndex } STATUS current DESCRIPTION "This trap indicate that the system started with non-default OS." ::= { dasanEvents 141 } slotBootedNonDefaultOS NOTIFICATION-TYPE OBJECTS { sleSlotSystemIndex } STATUS current DESCRIPTION "This trap indicate that the IU card started with non-default OS." ::= { dasanEvents 142 } -- 1.3.6.1.4.1.6296.0.145 cpuPpsOverThreshold NOTIFICATION-TYPE OBJECTS { slePerformanceBaseCpuPpsStatus, slePerformanceBaseCpuPpsThreshold, slePerformanceBaseCpuPpsAvg} STATUS current DESCRIPTION "The PPS of cpu is over the threshold." ::= { dasanEvents 145} -- 1.3.6.1.4.1.6296.0.146 cpuPpsUnderThreshold NOTIFICATION-TYPE OBJECTS { slePerformanceBaseCpuPpsStatus, slePerformanceBaseCpuPpsThreshold, slePerformanceBaseCpuPpsAvg} STATUS current DESCRIPTION "The PPS of cpu is under the threshold." ::= { dasanEvents 146} redundantPacketDetected NOTIFICATION-TYPE OBJECTS { } STATUS current DESCRIPTION "Redundant packets is detected." ::= { dasanEvents 147} redundantPacketDetectedCleared NOTIFICATION-TYPE OBJECTS { } STATUS current DESCRIPTION "Redundant packets detection is cleared." ::= { dasanEvents 148} -- GE-PON -- 1.3.6.1.4.1.6296.0.151 ponLinkFault NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "ONU reports a Link Fault via the flag in the 802.3ah OAM header.No further information about the fault is available.." ::= { dasanEvents 151 } -- 1.3.6.1.4.1.6296.0.152 ponLos NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Loss of Signal is detected by the PHY device for OLT Network interface, and PON interfaces on the OLT and ONU." ::= { dasanEvents 152 } -- 1.3.6.1.4.1.6296.0.153 ponTransmitFail NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Transmitted output does not match input, as reported by EPON optics." ::= { dasanEvents 153 } -- 1.3.6.1.4.1.6296.0.154 ponTransmitDegrade NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Transmitted output has a high error level, but not so high as to cause - Failure. Optionallyreported by EPON optical module." ::= { dasanEvents 154 } -- 1.3.6.1.4.1.6296.0.155 ponQueueOverflow NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "One of the queues for the link has dropped frames due to becoming full." ::= { dasanEvents 155 } -- 1.3.6.1.4.1.6296.0.156 ponMacLearningTableOverflow NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "MAC address learning table is full, not in overwrite mode, and a new MAC address wasencountered." ::= { dasanEvents 156 } -- 1.3.6.1.4.1.6296.0.157 ponDuplicateMacRegistration NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "MPCP register request received for MAC that is registered and in-service." ::= { dasanEvents 157 } -- 1.3.6.1.4.1.6296.0.158 ponReportTimeout NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "ONU does not respond to grants from the OLT." ::= { dasanEvents 158 } -- 1.3.6.1.4.1.6296.0.159 ponGateTimeout NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Excessive interval between MPCP gates." ::= { dasanEvents 159 } -- 1.3.6.1.4.1.6296.0.160 ponOAMKeepaliveTimeout NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "OAM KeepaliveTimeout - OAM layer does not receive periodic messages from its peer." ::= { dasanEvents 160 } -- 1.3.6.1.4.1.6296.0.161 ponKeyExchangeFailure NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "The link peer has failed to generate a new key message, or to switch to the new key, in the timeallotted by the key exchange timer for this link. Encryption remains in force using the old key, and the key exchange process continues.The alarm will clear when a new key is established." ::= { dasanEvents 161 } -- 1.3.6.1.4.1.6296.0.162 ponAutoNegotiation NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "OLT Network port fails to auto-negotiate with the peer (if auto-negotiation feature is enabled)." ::= { dasanEvents 162 } -- 1.3.6.1.4.1.6296.0.163 ponLinkLoopback NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "The link is currently in the loopback state." ::= { dasanEvents 163 } -- 1.3.6.1.4.1.6296.0.164 ponStandardDyingGasp NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "ONU reports Dying Gasp via that bit in 802.3ah OAM header." ::= { dasanEvents 164 } -- 1.3.6.1.4.1.6296.0.165 ponPowerFail NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Power supply failure." ::= { dasanEvents 165 } -- 1.3.6.1.4.1.6296.0.166 ponTemperature NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Operating temperature range exceeded." ::= { dasanEvents 166 } -- 1.3.6.1.4.1.6296.0.167 ponAuthenticationInformationUnavailable NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "ONU is configured to use external authentication device, and that device is not present." ::= { dasanEvents 167 } -- 1.3.6.1.4.1.6296.0.171 ponOctetsTransferred NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Octets Transferred." ::= { dasanEvents 171 } -- 1.3.6.1.4.1.6296.0.172 ponTotalFramesTransferred NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Total frames transferred." ::= { dasanEvents 172 } -- 1.3.6.1.4.1.6296.0.173 ponUnicastFramesTransferred NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Unicast frames transferred." ::= { dasanEvents 173 } -- 1.3.6.1.4.1.6296.0.174 ponBroadcastFramesTransferred NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Broadcast frames transferred." ::= { dasanEvents 174 } -- 1.3.6.1.4.1.6296.0.175 ponMulticastFramesTransferred NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Multicast frames transferred." ::= { dasanEvents 175 } -- 1.3.6.1.4.1.6296.0.176 ponCRC32Errors NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "CRC-32 Errors." ::= { dasanEvents 176 } -- 1.3.6.1.4.1.6296.0.177 ponUndersizeFrames NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Undersize Frames." ::= { dasanEvents 177 } -- 1.3.6.1.4.1.6296.0.178 ponOversizeFrames NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Oversize Frames." ::= { dasanEvents 178 } -- 1.3.6.1.4.1.6296.0.179 ponCollisions NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Collisions." ::= { dasanEvents 179 } -- 1.3.6.1.4.1.6296.0.180 pon64OctetFrames NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "64 Octet Frames." ::= { dasanEvents 180 } -- 1.3.6.1.4.1.6296.0.181 pon127OctetFrames NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "65-127 Octet Frames." ::= { dasanEvents 181 } -- 1.3.6.1.4.1.6296.0.182 pon255OctetFrames NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "128-255 Octet Frames." ::= { dasanEvents 182 } -- 1.3.6.1.4.1.6296.0.183 pon511OctetFrames NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "256-511 Octet Frames." ::= { dasanEvents 183 } -- 1.3.6.1.4.1.6296.0.184 pon1023OctetFrames NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "512-1023 Octet Frames." ::= { dasanEvents 184 } -- 1.3.6.1.4.1.6296.0.185 pon1518OctetFrames NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "1024-1518 Octet Frames." ::= { dasanEvents 185 } -- 1.3.6.1.4.1.6296.0.186 pon1519OverOctetFrames NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "1519+ Octet Frames." ::= { dasanEvents 186 } -- 1.3.6.1.4.1.6296.0.187 ponFramesDropped NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Frames dropped." ::= { dasanEvents 187 } -- 1.3.6.1.4.1.6296.0.188 ponOctetsDropped NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Octets dropped." ::= { dasanEvents 188 } -- 1.3.6.1.4.1.6296.0.189 ponOctetsDelayed NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Octets delayed." ::= { dasanEvents 189 } -- 1.3.6.1.4.1.6296.0.190 ponOctetsGranted NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Octets granted." ::= { dasanEvents 190 } -- 1.3.6.1.4.1.6296.0.191 ponOctetsGrantedButUnused NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Octets granted but unused." ::= { dasanEvents 191 } -- 1.3.6.1.4.1.6296.0.192 ponMaximumDelay NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "Maximum Delay (units of 100usec)." ::= { dasanEvents 192 } -- 1.3.6.1.4.1.6296.0.193 ponCRC8Errors NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION "CRC-8 (preamble) Errors." ::= { dasanEvents 193 } -- 1.3.6.1.4.1.6296.0.194 ponLineCodeErrors NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonPortIndex, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION " Line code errors " ::= { dasanEvents 194 } -- 1.3.6.1.4.1.6296.0.195 ponPauseFrames NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonPortIndex, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION " Pause Frames " ::= { dasanEvents 195 } -- 1.3.6.1.4.1.6296.0.196 ponErroredFrameSeconds NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonPortIndex, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION " Errored Frame Seconds " ::= { dasanEvents 196 } -- 1.3.6.1.4.1.6296.0.197 ponErroredFramePeriod NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonPortIndex, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION " Errored Frame Period " ::= { dasanEvents 197 } -- 1.3.6.1.4.1.6296.0.198 ponErroredFrameSecondsSummary NOTIFICATION-TYPE OBJECTS { dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonTaggedLabel, dsPonPortIndex, dsPonQueueIndex, dsPonDirection, dsPonState, dsPonCount } STATUS current DESCRIPTION " Errored Frame Seconds Summary " ::= { dasanEvents 198 } -- 1.3.6.1.4.1.6296.0.200 gponOnuRegistered NOTIFICATION-TYPE OBJECTS { sysDescr, sleAgentAddress, sleGponOltId, sleGponOnuId, sleGponOnuSerial, sleGponOnuIsFirst } STATUS current DESCRIPTION " Registered Onu Informations " ::= { dasanEvents 200 } -- 1.3.6.1.4.1.6296.0.201 gponOnuDeregistered NOTIFICATION-TYPE OBJECTS { sysDescr, sleAgentAddress, sleGponOltId, sleGponOnuId, sleGponOnuSerial } STATUS current DESCRIPTION " Deregistered Onu Informations " ::= { dasanEvents 201 } -- 1.3.6.1.4.1.6296.0.202 swWatchdogDetectError NOTIFICATION-TYPE OBJECTS { sleSwWatchdogType } STATUS current DESCRIPTION " S/W Watchdog Detect Error " ::= { dasanEvents 202 } -- 1.3.6.1.4.1.6296.0.203 swWatchdogClearError NOTIFICATION-TYPE OBJECTS { sleSwWatchdogType } STATUS current DESCRIPTION " S/W Watchdog Clear Error " ::= { dasanEvents 203 } -- 1.3.6.1.4.1.6296.0.204 swWatchdogNormalState NOTIFICATION-TYPE OBJECTS { sleSwWatchdogType } STATUS current DESCRIPTION " S/W Watchdog Normal State " ::= { dasanEvents 204 } -- 1.3.6.1.4.1.6296.0.205 swWatchdogAbnomalState NOTIFICATION-TYPE OBJECTS { sleSwWatchdogType } STATUS current DESCRIPTION " S/W Watchdog Abnormal State " ::= { dasanEvents 205 } -- 1.3.6.1.4.1.6296.0.206 gponOnuUpgradeCompleted NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId, sleGponOnuSerial, sleGponOnuNosUpgradeStatus } STATUS current DESCRIPTION " Upgrade Completed Onu Informations " ::= { dasanEvents 206 } -- 1.3.6.1.4.1.6296.0.207 gponOltCableDown NOTIFICATION-TYPE OBJECTS { sleGponOltId } STATUS current DESCRIPTION " GPON Cable down event is detected.(This is not used for any product)" ::= { dasanEvents 207 } -- 1.3.6.1.4.1.6296.0.208 gponOnuAutoToManual NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId, sleGponOnuSerial } STATUS current DESCRIPTION " GPON Onu is auto-to-manual " ::= { dasanEvents 208 } -- 1.3.6.1.4.1.6296.0.209 slotActionEvent NOTIFICATION-TYPE OBJECTS { sleSlotSystemIndex, sleSlotStatusCurrentInstallCardType, sleSlotStatusActionEvent } STATUS current DESCRIPTION " This trap indicates the slot action event " ::= { dasanEvents 209 } -- 1.3.6.1.4.1.6296.0.210 slotStateChanged NOTIFICATION-TYPE OBJECTS { sleSlotSystemIndex, sleSlotStatusCurrentInstallCardType, sleSlotStatusState } STATUS current DESCRIPTION " This trap indicates the slot state is changed " ::= { dasanEvents 210 } -- 1.3.6.1.4.1.6296.0.211 gponNoAuthONU NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId, sleGponOnuAthenticationStatus } STATUS current DESCRIPTION " No autheticated ONU " ::= { dasanEvents 211 } -- 1.3.6.1.4.1.6296.0.212 gponDuplicateONU NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId, sleGponOnuSerial } STATUS current DESCRIPTION " Duplicated ONU " ::= { dasanEvents 212 } -- 1.3.6.1.4.1.6296.0.213 gponDyingGasp NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId, sleGponOnuSerial } STATUS current DESCRIPTION "Dying Gasp of GPON ONU " ::= { dasanEvents 213 } -- 1.3.6.1.4.1.6296.0.214 gponRogueOnu NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId, sleGponOnuSerial } STATUS current DESCRIPTION "Found Rogue ONU. " ::= { dasanEvents 214 } -- 1.3.6.1.4.1.6296.0.215 gponOnuBatteryEvent NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId, sleGponOnuBatteryStatus } STATUS current DESCRIPTION "Battery Event. " ::= { dasanEvents 215 } -- 1.3.6.1.4.1.6296.0.216 gponOnuBatteryEventCleared NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId, sleGponOnuBatteryStatus } STATUS current DESCRIPTION "Battery Event is cleared. " ::= { dasanEvents 216 } -- 1.3.6.1.4.1.6296.0.217 gponOnuPortOperStatus NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId, sleGponOnuSerial, sleGponOnuPortId, sleGponOnuDescription, sleGponOnuPortControlSlotId, sleGponOnuPortControlUniDescription, sleGponOnuPortOperStatus } STATUS current DESCRIPTION " This trap indicates state of ONU Port Operation. " ::= { dasanEvents 217 } -- 1.3.6.1.4.1.6296.0.218 gponTransceiverChanged NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOltTransceiverPort } STATUS current DESCRIPTION " This trap indicates GPON transceiver changed. " ::= { dasanEvents 218 } -- 1.3.6.1.4.1.6296.0.219 gponOltLosOn NOTIFICATION-TYPE OBJECTS { sleGponOltId } STATUS current DESCRIPTION " This trap indicates state of OLT Loss Of Signal (on). " ::= { dasanEvents 219 } -- 1.3.6.1.4.1.6296.0.220 gponOltLosOff NOTIFICATION-TYPE OBJECTS { sleGponOltId } STATUS current DESCRIPTION " This trap indicates state of OLT Loss Of Signal (off). " ::= { dasanEvents 220 } -- 1.3.6.1.4.1.6296.0.221 gponOltLosiOn NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION " This trap indicates state of OLT Loss Of Signal for ONUi (on). " ::= { dasanEvents 221 } -- 1.3.6.1.4.1.6296.0.222 gponOltLosiOff NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION " This trap indicates state of OLT Loss Of Signal for ONUi (off). " ::= { dasanEvents 222 } -- 1.3.6.1.4.1.6296.0.223 gponDyingGaspOn NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId, sleGponOnuSerial } STATUS current DESCRIPTION "This trap indicates Dying Gasp of GPON ONU (on). " ::= { dasanEvents 223 } -- 1.3.6.1.4.1.6296.0.224 gponDyingGaspOff NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId, sleGponOnuSerial } STATUS current DESCRIPTION "This trap indicates Dying Gasp of GPON ONU (off). " ::= { dasanEvents 224 } -- 1.3.6.1.4.1.6296.0.225 slotErrorLEDChanged NOTIFICATION-TYPE OBJECTS { sleSlotSystemIndex } STATUS current DESCRIPTION "This trap indicates slot error LED changed. " ::= { dasanEvents 225 } -- 1.3.6.1.4.1.6296.0.226 nmsConnectionTypeChanged NOTIFICATION-TYPE OBJECTS { sleSnmpConnectionType } STATUS current DESCRIPTION "This trap indicates NMS connection type changed. " ::= { dasanEvents 226 } -- 1.3.6.1.4.1.6296.0.227 gponOntOSUpgradeStatus NOTIFICATION-TYPE OBJECTS { sleGponOntFirmwareOltId, sleGponOntFirmwareOntId, sleGponOntFirmwareOntOsStatus } STATUS current DESCRIPTION "This trap indicates ONT OS upgrade status changes. " ::= { dasanEvents 227 } -- 1.3.6.1.4.1.6296.0.228 gponOntBLUpgradeStatus NOTIFICATION-TYPE OBJECTS { sleGponOntFirmwareOltId, sleGponOntFirmwareOntId, sleGponOntFirmwareOntOsStatus } STATUS current DESCRIPTION "This trap indicates ONT BL upgrade status changes. " ::= { dasanEvents 228 } -- 1.3.6.1.4.1.6296.0.229 gponOntRxPowerLoss NOTIFICATION-TYPE OBJECTS { sleGponOltId } STATUS current DESCRIPTION "This trap indicates ONT port failed to detect Rx Power. " ::= { dasanEvents 229 } -- 1.3.6.1.4.1.6296.0.230 gponOntRxPowerDetected NOTIFICATION-TYPE OBJECTS { sleGponOltId } STATUS current DESCRIPTION "This trap indicates ONT port detected Rx Power. " ::= { dasanEvents 230 } -- 1.3.6.1.4.1.6296.0.231 gponOnuTemperatureHighOverThreshold NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "This trap indicates the temperature of ONU is over high threshold. " ::= { dasanEvents 231 } -- 1.3.6.1.4.1.6296.0.232 gponOnuTemperatureHighFallThreshold NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "This trap indicates the temperature of ONU falls under high threshold. " ::= { dasanEvents 232 } -- 1.3.6.1.4.1.6296.0.233 gponOnuTemperatureLowOverThreshold NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "This trap indicates the temperature of ONU is over low threshold. " ::= { dasanEvents 233 } -- 1.3.6.1.4.1.6296.0.234 gponOnuTemperatureLowFallThreshold NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "This trap indicates the temperature of ONU falls under low threshold. " ::= { dasanEvents 234 } -- 1.3.6.1.4.1.6296.0.235 gponOnuCpuOverThreshold NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "This trap indicates the CPU-load of ONU is over threshold. " ::= { dasanEvents 235 } -- 1.3.6.1.4.1.6296.0.236 gponOnuCpuFallThreshold NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "This trap indicates the CPU-load of ONU falls under threshold. " ::= { dasanEvents 236 } -- 1.3.6.1.4.1.6296.0.237 gponOnuMemoryOverThreshold NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "This trap indicates the memory-utilization of ONU is over threshold. " ::= { dasanEvents 237 } -- 1.3.6.1.4.1.6296.0.238 gponOnuMemoryFallThreshold NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "This trap indicates the memory-utilization of ONU falls under threshold. " ::= { dasanEvents 238 } -- 1.3.6.1.4.1.6296.0.239 gponOnuI2cFail NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "This trap indicates that detect ONU's i2c fail." ::= { dasanEvents 239 } -- 1.3.6.1.4.1.6296.0.240 gponOnuRxOpticPowerLowThreshAlarmOn NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "RX optic low power alarm is detected" ::= { dasanEvents 240 } -- 1.3.6.1.4.1.6296.0.241 gponOnuRxOpticPowerLowThreshAlarmOff NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "RX optic low power alarm is cleared" ::= { dasanEvents 241 } -- 1.3.6.1.4.1.6296.0.242 gponOnuRxOpticPowerHighThreshAlarmOn NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "RX Optic over power alarm is detected" ::= { dasanEvents 242 } -- 1.3.6.1.4.1.6296.0.243 gponOnuRxOpticPowerHighThreshAlarmOff NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "RX Optic over power alarm is cleared." ::= { dasanEvents 243 } -- 1.3.6.1.4.1.6296.0.244 gponOltLOFIOn NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT LOFI alarm is detected" ::= { dasanEvents 244 } -- 1.3.6.1.4.1.6296.0.245 gponOltLOFIOff NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT LOFI alarm is cleared" ::= { dasanEvents 245 } -- 1.3.6.1.4.1.6296.0.246 gponOltDOWOn NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT DOW alarm is detected" ::= { dasanEvents 246 } -- 1.3.6.1.4.1.6296.0.247 gponOltDOWOff NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT DOW alarm is cleared" ::= { dasanEvents 247 } -- 1.3.6.1.4.1.6296.0.248 gponOltSFOn NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT SF alarm is detected" ::= { dasanEvents 248 } -- 1.3.6.1.4.1.6296.0.249 gponOltSFOff NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT SF alarm is cleared" ::= { dasanEvents 249 } -- 1.3.6.1.4.1.6296.0.250 gponOltSDOn NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT SD alarm is detected" ::= { dasanEvents 250 } -- 1.3.6.1.4.1.6296.0.251 gponOltSDOff NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT SD alarm is cleared" ::= { dasanEvents 251 } -- 1.3.6.1.4.1.6296.0.252 gponOltLCDGIOn NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT LCDGI alarm is detected" ::= { dasanEvents 252 } -- 1.3.6.1.4.1.6296.0.253 gponOltLCDGIOff NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT LCDGI alarm is cleared" ::= { dasanEvents 253 } -- 1.3.6.1.4.1.6296.0.254 gponOltRDOn NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT RD alarm is detected" ::= { dasanEvents 254 } -- 1.3.6.1.4.1.6296.0.255 gponOltRDOff NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT RD alarm is cleared" ::= { dasanEvents 255 } -- 1.3.6.1.4.1.6296.0.256 gponOltSUFOn NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT SUF alarm is detected" ::= { dasanEvents 256 } -- 1.3.6.1.4.1.6296.0.257 gponOltSUFOff NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT SUF alarm is cleared" ::= { dasanEvents 257 } -- 1.3.6.1.4.1.6296.0.258 gponOltLOAOn NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT LOA alarm is detected" ::= { dasanEvents 258 } -- 1.3.6.1.4.1.6296.0.259 gponOltLOAOff NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT LOA alarm is cleared" ::= { dasanEvents 259 } -- 1.3.6.1.4.1.6296.0.260 gponOltLOAMIOn NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT LOAMI alarm is detected" ::= { dasanEvents 260 } -- 1.3.6.1.4.1.6296.0.261 gponOltLOAMIOff NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT LOAMI alarm is cleared" ::= { dasanEvents 261 } -- 1.3.6.1.4.1.6296.0.262 gponOltMEMOn NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT MEM alarm is detected" ::= { dasanEvents 262 } -- 1.3.6.1.4.1.6296.0.263 gponOltMEMOff NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT MEM alarm is cleared" ::= { dasanEvents 263 } -- 1.3.6.1.4.1.6296.0.264 gponOltPEEOn NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT PEE alarm is detected" ::= { dasanEvents 264 } -- 1.3.6.1.4.1.6296.0.265 gponOltPEEOff NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT PEE alarm is cleared" ::= { dasanEvents 265 } -- 1.3.6.1.4.1.6296.0.266 gponOltPSTOn NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT PST alarm is detected" ::= { dasanEvents 266 } -- 1.3.6.1.4.1.6296.0.267 gponOltPSTOff NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT PST alarm is cleared" ::= { dasanEvents 267 } -- 1.3.6.1.4.1.6296.0.268 gponOltERROn NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT alarm error is detected" ::= { dasanEvents 268 } -- 1.3.6.1.4.1.6296.0.269 gponOltERROff NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT alarm error is cleared" ::= { dasanEvents 269 } -- 1.3.6.1.4.1.6296.0.270 gponOltREIOn NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT REI alarm is detected" ::= { dasanEvents 270 } -- 1.3.6.1.4.1.6296.0.271 gponOltREIOff NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "OLT REI alarm is cleared." ::= { dasanEvents 271 } -- 1.3.6.1.4.1.6296.0.272 gponAntiSpoofingDupPortOn NOTIFICATION-TYPE OBJECTS { sleGponAntiSpoofingOltId, sleGponAntiSpoofingOnuId, sleGponAntiSpoofingVlanId, sleGponAntiSpoofingMac } STATUS current DESCRIPTION "Anti spoofing duplication port alarm is detected" ::= { dasanEvents 272 } -- 1.3.6.1.4.1.6296.0.273 gponAntiSpoofingDupPortOff NOTIFICATION-TYPE OBJECTS { sleGponAntiSpoofingOltId, sleGponAntiSpoofingOnuId, sleGponAntiSpoofingVlanId, sleGponAntiSpoofingMac } STATUS current DESCRIPTION "Anti spoofing duplication port alarm is cleared" ::= { dasanEvents 273 } -- 1.3.6.1.4.1.6296.0.274 gponRedundancySwitchOver NOTIFICATION-TYPE OBJECTS {sleGponRedGroupIndex, sleGponRedGroupOltAIndex, sleGponRedGroupOltAStatus, sleGponRedGroupOltBIndex, sleGponRedGroupOltBStatus, sleGponRedLastReason } STATUS current DESCRIPTION "Redundancy switch over" ::= { dasanEvents 274 } -- 1.3.6.1.4.1.6296.0.275 gponDuplicatedRangingResponse NOTIFICATION-TYPE OBJECTS {sleGponOltId, sleGponOnuId} STATUS current DESCRIPTION "Duplicated ranging response detection." ::= { dasanEvents 275 } -- 1.3.6.1.4.1.6296.0.276 gponOnuPortOpticModuleInstall NOTIFICATION-TYPE OBJECTS {sleGponOltId, sleGponOnuId, sleGponOnuPortSlotId, sleGponOnuPortId } STATUS current DESCRIPTION "ONU port optic module install detection." ::= { dasanEvents 276 } -- 1.3.6.1.4.1.6296.0.277 gponOnuPortOpticModuleRemove NOTIFICATION-TYPE OBJECTS {sleGponOltId, sleGponOnuId, sleGponOnuPortSlotId, sleGponOnuPortId } STATUS current DESCRIPTION "ONU port optic module removal detection." ::= { dasanEvents 277 } -- 1.3.6.1.4.1.6296.0.278 gponOnuOMCCProblemDetected NOTIFICATION-TYPE OBJECTS {sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "ONU OMCC Problem is detected." ::= { dasanEvents 278 } -- 1.3.6.1.4.1.6296.0.279 gponOnuOMCCProblemCleared NOTIFICATION-TYPE OBJECTS {sleGponOltId, sleGponOnuId } STATUS current DESCRIPTION "ONU OMCC Problem is cleared." ::= { dasanEvents 279 } -- 1.3.6.1.4.1.6296.0.280 gponOltFixedTcontAlarmOn NOTIFICATION-TYPE OBJECTS {sleGponOltId, sleGponOltFixedTcontCount} STATUS current DESCRIPTION "OLT fixed tcont alarm is detected" ::= { dasanEvents 280 } -- 1.3.6.1.4.1.6296.0.281 gponOltFixedTcontAlarmOff NOTIFICATION-TYPE OBJECTS {sleGponOltId, sleGponOltFixedTcontCount} STATUS current DESCRIPTION "OLT fixed tcont alarm is cleared" ::= { dasanEvents 281 } -- 1.3.6.1.4.1.6296.0.282 gponOltDynamicTcontAlarmOn NOTIFICATION-TYPE OBJECTS {sleGponOltId, sleGponOltDynamicTcontCount} STATUS current DESCRIPTION "OLT dynamic tcont alarm is detected." ::= { dasanEvents 282 } -- 1.3.6.1.4.1.6296.0.283 gponOltDynamicTcontAlarmOff NOTIFICATION-TYPE OBJECTS {sleGponOltId, sleGponOltDynamicTcontCount} STATUS current DESCRIPTION "OLT dynamic tcont alarm is cleared." ::= { dasanEvents 283 } -- 1.3.6.1.4.1.6296.0.284 gponOltPortCountAlarmOn NOTIFICATION-TYPE OBJECTS {sleGponOltId, sleGponOltPortCount} STATUS current DESCRIPTION "OLT port count alarm is detected." ::= { dasanEvents 284 } -- 1.3.6.1.4.1.6296.0.285 gponOltPortCountAlarmOff NOTIFICATION-TYPE OBJECTS {sleGponOltId, sleGponOltPortCount} STATUS current DESCRIPTION "OLT port count alarm is cleared." ::= { dasanEvents 285 } -- 1.3.6.1.4.1.6296.0.286 gponOltCableDownAlarmOn NOTIFICATION-TYPE OBJECTS {sleGponOltId} STATUS current DESCRIPTION "GPON Cable down event is detected" ::= { dasanEvents 286 } -- 1.3.6.1.4.1.6296.0.287 gponOltCableDownAlarmOff NOTIFICATION-TYPE OBJECTS {sleGponOltId} STATUS current DESCRIPTION "GPON Cable down event is cleared" ::= { dasanEvents 287 } -- 1.3.6.1.4.1.6296.0.288 gponOltDeactiveMonitorAlarmOn NOTIFICATION-TYPE OBJECTS {sleGponOltId} STATUS current DESCRIPTION "GPON deactive monitor alarm is on" ::= { dasanEvents 288 } -- 1.3.6.1.4.1.6296.0.289 gponOltDeactiveMonitorAlarmOff NOTIFICATION-TYPE OBJECTS {sleGponOltId} STATUS current DESCRIPTION "GPON deactive monitor alarm is off" ::= { dasanEvents 289 } -- 1.3.6.1.4.1.6296.0.290 gponOltDFION NOTIFICATION-TYPE OBJECTS {sleGponOltId, sleGponOnuId} STATUS current DESCRIPTION "GPON OLT DFI is on" ::= { dasanEvents 290 } -- 1.3.6.1.4.1.6296.0.291 gponOltDFIOFF NOTIFICATION-TYPE OBJECTS {sleGponOltId, sleGponOnuId} STATUS current DESCRIPTION "GPON OLT DFI is off" ::= { dasanEvents 291 } -- 1.3.6.1.4.1.6296.0.294 gponOltTransceiverPortChanged NOTIFICATION-TYPE OBJECTS {sleGponOltId, sleGponOltTransceiverPort} STATUS current DESCRIPTION "GPON OLT Transceiver alarm is changed" ::= { dasanEvents 294 } -- 1.3.6.1.4.1.6296.0.295 gponOltRxOpticPowerHighThresOver NOTIFICATION-TYPE OBJECTS {sleGponOltId, sleGponOnuId} STATUS current DESCRIPTION "GPON OLT power high threshold is over" ::= { dasanEvents 295 } -- 1.3.6.1.4.1.6296.0.296 gponOltRxOpticPowerHighThresOverCleared NOTIFICATION-TYPE OBJECTS {sleGponOltId, sleGponOnuId} STATUS current DESCRIPTION "GPON OLT power high threshold over is cleared " ::= { dasanEvents 296 } -- 1.3.6.1.4.1.6296.0.297 gponOltRxOpticPowerLowThresUnder NOTIFICATION-TYPE OBJECTS {sleGponOltId, sleGponOnuId} STATUS current DESCRIPTION "GPON OLT power low threshold is under" ::= { dasanEvents 297 } -- 1.3.6.1.4.1.6296.0.298 gponOltRxOpticPowerLowThresUnderCleared NOTIFICATION-TYPE OBJECTS {sleGponOltId, sleGponOnuId} STATUS current DESCRIPTION "GPON OLT power low threshold under is cleared" ::= { dasanEvents 298 } -- 1.3.6.1.4.1.6296.0.301 oamRapsEastPortStatusChanged NOTIFICATION-TYPE OBJECTS {sleY1731MegIndex, sleY1731MegRapsEastPortStatus} STATUS current DESCRIPTION "The east port status changed" ::= { dasanEvents 301 } -- 1.3.6.1.4.1.6296.0.302 oamRapsWestPortStatusChanged NOTIFICATION-TYPE OBJECTS {sleY1731MegIndex, sleY1731MegRapWestPortStatus} STATUS current DESCRIPTION "The west port status changed" ::= { dasanEvents 302 } -- 1.3.6.1.4.1.6296.0.303 oamURNodePortStatusChanged NOTIFICATION-TYPE OBJECTS {sleY1731URMegIndex, sleY1731URNodeConfPortNum, sleY1731URNodeConfPortStatus} STATUS current DESCRIPTION "OAM uplink redundancy node's port status changed" ::= { dasanEvents 303 } -- 1.3.6.1.4.1.6296.0.320 loopDetectBlocked NOTIFICATION-TYPE OBJECTS {sleBridgePortIndex} STATUS current DESCRIPTION "This trap indicate the Port is blocked by loop-detect." ::= { dasanEvents 320} -- 1.3.6.1.4.1.6296.0.321 loopDetectUnBlockedbyExpireTimer NOTIFICATION-TYPE OBJECTS {sleBridgePortIndex} STATUS current DESCRIPTION "This trap indicate the Port is unblocked by loop-detect's expire timer." ::= { dasanEvents 321} -- 1.3.6.1.4.1.6296.0.322 loopDetectUnBlockedbyLinkDown NOTIFICATION-TYPE OBJECTS {sleBridgePortIndex} STATUS current DESCRIPTION "This trap indicate the Port is unblocked by loop-detect's link down." ::= { dasanEvents 322} writeMemoryFailSeveralTimes NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap indicates the writing memory is failed 3 times" ::= { dasanEvents 341 } writeMemoryFailSeveralTimesCleared NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap indicates the writing memory is ok" ::= { dasanEvents 342 } -- EM Log emLogDefectCPUHighOver NOTIFICATION-TYPE OBJECTS {sleEMLogDefectCPUHigh} STATUS current DESCRIPTION "EM log about CPU load high over." ::= { dasanEvents 351 } emLogDefectCPUHighUnder NOTIFICATION-TYPE OBJECTS {sleEMLogDefectCPUHigh} STATUS current DESCRIPTION "EM log about CPU load high under." ::= { dasanEvents 352 } emLogTemperHighOver NOTIFICATION-TYPE OBJECTS {sleEMLogTemperHigh} STATUS current DESCRIPTION "EM log about temperature high over." ::= { dasanEvents 353 } emLogTemperHighUnder NOTIFICATION-TYPE OBJECTS {sleEMLogTemperHigh} STATUS current DESCRIPTION "EM log about temperature high under." ::= { dasanEvents 354 } emLogTemperLowUnder NOTIFICATION-TYPE OBJECTS {sleEMLogTemperLow} STATUS current DESCRIPTION "EM log about temperature low under (occured)." ::= { dasanEvents 355 } emLogTemperLowOver NOTIFICATION-TYPE OBJECTS {sleEMLogTemperLow} STATUS current DESCRIPTION "EM log about temperature low under (cleared)." ::= { dasanEvents 356 } emLogMemLowUnder NOTIFICATION-TYPE OBJECTS {sleEMLogMemLow} STATUS current DESCRIPTION "EM log about memory low over (occured)." ::= { dasanEvents 358 } emLogMemLowOver NOTIFICATION-TYPE OBJECTS {sleEMLogMemLow} STATUS current DESCRIPTION "EM log about memory low over (cleared)." ::= { dasanEvents 357 } emLogFanFail NOTIFICATION-TYPE OBJECTS {sleEMLogFanFail} STATUS current DESCRIPTION "EM log about fan fail." ::= { dasanEvents 359 } emLogFanFailCleared NOTIFICATION-TYPE OBJECTS {sleEMLogFanFail} STATUS current DESCRIPTION "EM log about fan fail cleared." ::= { dasanEvents 360 } emLogPhyCRCFail NOTIFICATION-TYPE OBJECTS {sleEMLogPhyCRCFail} STATUS current DESCRIPTION "EM log about PHY CRC fail." ::= { dasanEvents 361 } emLogPhyCRCFailCleared NOTIFICATION-TYPE OBJECTS {sleEMLogPhyCRCFail} STATUS current DESCRIPTION "EM log about PHY CRC fail cleared." ::= { dasanEvents 362 } emLogPhyDetectFail NOTIFICATION-TYPE OBJECTS {sleEMLogPhyDetectFail} STATUS current DESCRIPTION "EM log about PHY detect fail." ::= { dasanEvents 363 } emLogPhyDetectFailCleared NOTIFICATION-TYPE OBJECTS {sleEMLogPhyDetectFail} STATUS current DESCRIPTION "EM log about PHY detect fail cleared." ::= { dasanEvents 364 } emLogSFUMateInitFail NOTIFICATION-TYPE OBJECTS {sleEMLogSFUMateInitFail} STATUS current DESCRIPTION "EM log about SFU mate init fail" ::= { dasanEvents 365 } emLogSFUMateInitFailCleared NOTIFICATION-TYPE OBJECTS {sleEMLogSFUMateInitFail} STATUS current DESCRIPTION "EM log about SFU mate init fail cleared" ::= { dasanEvents 366 } emLogDaemonHealthBad NOTIFICATION-TYPE OBJECTS {sleEMLogDaemonHealthBad} STATUS current DESCRIPTION "EM log about daemon health bad" ::= { dasanEvents 367 } emLogDaemonHealthBadCleared NOTIFICATION-TYPE OBJECTS {sleEMLogDaemonHealthBad} STATUS current DESCRIPTION "EM log about daemon health bad cleared" ::= { dasanEvents 368 } emLogGPIURavenLinkDown NOTIFICATION-TYPE OBJECTS {sleEMLogGPIURavenLinkDown} STATUS current DESCRIPTION "EM log about GPIU raven link down" ::= { dasanEvents 369 } emLogGPIURavenLinkDownCleared NOTIFICATION-TYPE OBJECTS {sleEMLogGPIURavenLinkDown} STATUS current DESCRIPTION "EM log about GPIU raven link down cleared" ::= { dasanEvents 370 } bootSequenceConfigFile NOTIFICATION-TYPE STATUS current DESCRIPTION "Boot Sequence Config File failed" ::= { dasanEvents 371 } topologyChanged NOTIFICATION-TYPE STATUS current DESCRIPTION "Topolgy changed" ::= { dasanEvents 372 } configLoadFail NOTIFICATION-TYPE STATUS current DESCRIPTION "Config load failed" ::= { dasanEvents 373 } emlogFanRPMLow NOTIFICATION-TYPE STATUS current DESCRIPTION "FAN RPM Low detected in EMLOG" ::= { dasanEvents 375 } emlogFanRPMLowCleared NOTIFICATION-TYPE STATUS current DESCRIPTION "FAN RPM Low cleared in EMLOG" ::= { dasanEvents 376 } emlogNAKError NOTIFICATION-TYPE STATUS current DESCRIPTION "NAK Error detected in EMLOG" ::= { dasanEvents 377 } emlogNAKErrorCleared NOTIFICATION-TYPE STATUS current DESCRIPTION "NAK Error cleared in EMLOG" ::= { dasanEvents 378 } gponOnuAniVoltageLowThreshAlarmOn NOTIFICATION-TYPE STATUS current DESCRIPTION "Voltage low threshold alarm on" ::= { dasanEvents 381 } gponOnuAniVoltageLowThreshAlarmOff NOTIFICATION-TYPE STATUS current DESCRIPTION "Voltage low threshold alarm off" ::= { dasanEvents 382 } gponOnuAniVoltageHighThreshAlarmOn NOTIFICATION-TYPE STATUS current DESCRIPTION "Voltage high threshold alarm on" ::= { dasanEvents 383 } gponOnuAniVoltageHighThreshAlarmOff NOTIFICATION-TYPE STATUS current DESCRIPTION "Voltage high threshold alarm off" ::= { dasanEvents 384 } gponOnuAniTemperatureLowThreshAlarmOn NOTIFICATION-TYPE STATUS current DESCRIPTION "Temperature low threshold alarm on" ::= { dasanEvents 385 } gponOnuAniTemperatureLowThreshAlarmOff NOTIFICATION-TYPE STATUS current DESCRIPTION "Temperature high threshold alarm off" ::= { dasanEvents 386 } gponOnuAniTemperatureHighThreshAlarmOn NOTIFICATION-TYPE STATUS current DESCRIPTION "Temperature high threshold alarm on" ::= { dasanEvents 387 } gponOnuAniTemperatureHighThreshAlarmOff NOTIFICATION-TYPE STATUS current DESCRIPTION "Temperature high threshold alarm off" ::= { dasanEvents 388 } gponOnuAniTxBiasLowThreshAlarmOn NOTIFICATION-TYPE STATUS current DESCRIPTION "TX-bias low threshold alarm on" ::= { dasanEvents 389 } gponOnuAniTxBiasLowThreshAlarmOff NOTIFICATION-TYPE STATUS current DESCRIPTION "TX-bias low threshold alarm off" ::= { dasanEvents 390 } gponOnuAniTxBiasHighThreshAlarmOn NOTIFICATION-TYPE STATUS current DESCRIPTION "TX-bias high threshold alarm on" ::= { dasanEvents 391 } gponOnuAniTxBiasHighThreshAlarmOff NOTIFICATION-TYPE STATUS current DESCRIPTION "TX-bias high threshold alarm off" ::= { dasanEvents 392 } gponOnuAniTxpowerLowThreshAlarmOn NOTIFICATION-TYPE STATUS current DESCRIPTION "TX-power low threshold alarm on" ::= { dasanEvents 393 } gponOnuAniTxpowerLowThreshAlarmOff NOTIFICATION-TYPE STATUS current DESCRIPTION "TX-power low threshold alarm off" ::= { dasanEvents 394 } gponOnuAniTxpowerHighThreshAlarmOn NOTIFICATION-TYPE STATUS current DESCRIPTION "TX-power high threshold alarm on" ::= { dasanEvents 395 } gponOnuAniTxpowerHighThreshAlarmOff NOTIFICATION-TYPE STATUS current DESCRIPTION "TX-power high threshold alarm off" ::= { dasanEvents 396 } slotHealthStatusTimeout NOTIFICATION-TYPE OBJECTS { sleSlotSystemIndex } STATUS current DESCRIPTION " This trap indicates the slot health status time-out is occurred" ::= { dasanEvents 397 } slotHealthStatusTimeoutCleared NOTIFICATION-TYPE OBJECTS { sleSlotSystemIndex } STATUS current DESCRIPTION " This trap indicates the slot health status time-out trap is cleared " ::= { dasanEvents 398 } sfpDMIDiagTemperOverHighAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITemper } STATUS current DESCRIPTION " This trap indicates the temperature of sfp is over the high threshold.(Alarm) " ::= { dasanEvents 401 } sfpDMIDiagTemperUnderHighAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITemper } STATUS current DESCRIPTION " This trap indicates the temperature of sfp is under the high threshold.(Alarm)" ::= { dasanEvents 402 } sfpDMIDiagTemperUnderLowAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITemper } STATUS current DESCRIPTION " This trap indicates the temperature of sfp is under the low threshold.(Alarm)" ::= { dasanEvents 403 } sfpDMIDiagTemperOverLowAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITemper } STATUS current DESCRIPTION " This trap indicates the temperature of sfp is over the low threshold.(Alarm)" ::= { dasanEvents 404 } sfpDMIDiagTemperOverHighWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITemper } STATUS current DESCRIPTION " This trap indicates the temperature of sfp is over the high threshold.(Warn)" ::= { dasanEvents 405 } sfpDMIDiagTemperUnderHighWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITemper } STATUS current DESCRIPTION " This trap indicates the temperature of sfp is under the high threshold.(Warn)" ::= { dasanEvents 406 } sfpDMIDiagTemperUnderLowWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITemper } STATUS current DESCRIPTION " This trap indicates the temperature of sfp is under the low threshold.(Warn)" ::= { dasanEvents 407 } sfpDMIDiagTemperOverLowWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITemper } STATUS current DESCRIPTION " This trap indicates the temperature of sfp is over the low threshold.(Warn)" ::= { dasanEvents 408 } sfpDMIDiagVoltageOverHighAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMIVoltage } STATUS current DESCRIPTION " This trap indicates the voltage of sfp is over the high threshold.(Alarm) " ::= { dasanEvents 409 } sfpDMIDiagVoltageUnderHighAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMIVoltage } STATUS current DESCRIPTION " This trap indicates the voltage of sfp is under the high threshold.(Alarm)" ::= { dasanEvents 410 } sfpDMIDiagVoltageUnderLowAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMIVoltage } STATUS current DESCRIPTION " This trap indicates the voltage of sfp is under the low threshold.(Alarm)" ::= { dasanEvents 411 } sfpDMIDiagVoltageOverLowAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMIVoltage } STATUS current DESCRIPTION " This trap indicates the voltage of sfp is over the low threshold.(Alarm)" ::= { dasanEvents 412 } sfpDMIDiagVoltageOverHighWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMIVoltage } STATUS current DESCRIPTION " This trap indicates the voltage of sfp is over the high threshold.(Warn)" ::= { dasanEvents 413 } sfpDMIDiagVoltageUnderHighWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMIVoltage } STATUS current DESCRIPTION " This trap indicates the voltage of sfp is under the high threshold.(Warn)" ::= { dasanEvents 414 } sfpDMIDiagVoltageUnderLowWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMIVoltage } STATUS current DESCRIPTION " This trap indicates the voltage of sfp is under the low threshold.(Warn)" ::= { dasanEvents 415 } sfpDMIDiagVoltageOverLowWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMIVoltage } STATUS current DESCRIPTION " This trap indicates the voltage of sfp is over the low threshold.(Warn)" ::= { dasanEvents 416 } sfpDMIDiagTxBiasOverHighAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITxBias } STATUS current DESCRIPTION " This trap indicates the TxBias of sfp is over the high threshold.(Alarm) " ::= { dasanEvents 417 } sfpDMIDiagTxBiasUnderHighAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITxBias } STATUS current DESCRIPTION " This trap indicates the TxBias of sfp is under the high threshold.(Alarm)" ::= { dasanEvents 418 } sfpDMIDiagTxBiasUnderLowAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITxBias } STATUS current DESCRIPTION " This trap indicates the TxBias of sfp is under the low threshold.(Alarm)" ::= { dasanEvents 419 } sfpDMIDiagTxBiasOverLowAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITxBias } STATUS current DESCRIPTION " This trap indicates the TxBias of sfp is over the low threshold.(Alarm)" ::= { dasanEvents 420 } sfpDMIDiagTxBiasOverHighWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITxBias } STATUS current DESCRIPTION " This trap indicates the TxBias of sfp is over the high threshold.(Warn)" ::= { dasanEvents 421 } sfpDMIDiagTxBiasUnderHighWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITxBias } STATUS current DESCRIPTION " This trap indicates the TxBias of sfp is under the high threshold.(Warn)" ::= { dasanEvents 422 } sfpDMIDiagTxBiasUnderLowWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITxBias } STATUS current DESCRIPTION " This trap indicates the TxBias of sfp is under the low threshold.(Warn)" ::= { dasanEvents 423 } sfpDMIDiagTxBiasOverLowWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITxBias } STATUS current DESCRIPTION " This trap indicates the TxBias of sfp is over the low threshold.(Warn)" ::= { dasanEvents 424 } sfpDMIDiagTxPowerOverHighAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITxPower } STATUS current DESCRIPTION " This trap indicates the TxPower of sfp is over the high threshold.(Alarm) " ::= { dasanEvents 425 } sfpDMIDiagTxPowerUnderHighAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITxPower } STATUS current DESCRIPTION " This trap indicates the TxPower of sfp is under the high threshold.(Alarm)" ::= { dasanEvents 426 } sfpDMIDiagTxPowerUnderLowAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITxPower } STATUS current DESCRIPTION " This trap indicates the TxPower of sfp is under the low threshold.(Alarm)" ::= { dasanEvents 427 } sfpDMIDiagTxPowerOverLowAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITxPower } STATUS current DESCRIPTION " This trap indicates the TxPower of sfp is over the low threshold.(Alarm)" ::= { dasanEvents 428 } sfpDMIDiagTxPowerOverHighWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITxPower } STATUS current DESCRIPTION " This trap indicates the TxPower of sfp is over the high threshold.(Warn)" ::= { dasanEvents 429 } sfpDMIDiagTxPowerUnderHighWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITxPower } STATUS current DESCRIPTION " This trap indicates the TxPower of sfp is under the high threshold.(Warn)" ::= { dasanEvents 430 } sfpDMIDiagTxPowerUnderLowWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITxPower } STATUS current DESCRIPTION " This trap indicates the TxPower of sfp is under the low threshold.(Warn)" ::= { dasanEvents 431 } sfpDMIDiagTxPowerOverLowWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMITxPower } STATUS current DESCRIPTION " This trap indicates the TxPower of sfp is over the low threshold.(Warn)" ::= { dasanEvents 432 } sfpDMIDiagRxPowerOverHighAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMIRxPower } STATUS current DESCRIPTION " This trap indicates the RxPower of sfp is over the high threshold.(Alarm) " ::= { dasanEvents 433 } sfpDMIDiagRxPowerUnderHighAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMIRxPower } STATUS current DESCRIPTION " This trap indicates the RxPower of sfp is under the high threshold.(Alarm)" ::= { dasanEvents 434 } sfpDMIDiagRxPowerUnderLowAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMIRxPower } STATUS current DESCRIPTION " This trap indicates the RxPower of sfp is under the low threshold.(Alarm)" ::= { dasanEvents 435 } sfpDMIDiagRxPowerOverLowAlarm NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMIRxPower } STATUS current DESCRIPTION " This trap indicates the RxPower of sfp is over the low threshold.(Alarm)" ::= { dasanEvents 436 } sfpDMIDiagRxPowerOverHighWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMIRxPower } STATUS current DESCRIPTION " This trap indicates the RxPower of sfp is over the high threshold.(Warn)" ::= { dasanEvents 437 } sfpDMIDiagRxPowerUnderHighWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMIRxPower } STATUS current DESCRIPTION " This trap indicates the RxPower of sfp is under the high threshold.(Warn)" ::= { dasanEvents 438 } sfpDMIDiagRxPowerUnderLowWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMIRxPower } STATUS current DESCRIPTION " This trap indicates the RxPower of sfp is under the low threshold.(Warn)" ::= { dasanEvents 439 } sfpDMIDiagRxPowerOverLowWarn NOTIFICATION-TYPE OBJECTS { sleEthernetPortDMIIndex, sleEthernetPortDMIRxPower } STATUS current DESCRIPTION " This trap indicates the RxPower of sfp is over the low threshold.(Warn)" ::= { dasanEvents 440 } gponOnuOnuServiceOpModeAlarm NOTIFICATION-TYPE STATUS current DESCRIPTION "GPON ONU service operational mode alarm." ::= { dasanEvents 441 } gponOnuOnuServiceOpModeAlarmOff NOTIFICATION-TYPE STATUS current DESCRIPTION "GPON ONU service operational mode cleared alarm." ::= { dasanEvents 442 } systemTemperPowerCutOff NOTIFICATION-TYPE OBJECTS { } STATUS current DESCRIPTION "This trap indicates the system temperature power cut off" ::= { dasanEvents 443 } systemTemperPowerCutoffCleared NOTIFICATION-TYPE OBJECTS { } STATUS current DESCRIPTION "This trap indicates the system temperature power cut off trap is cleared" ::= { dasanEvents 444 } slotTemperPowerCutOff NOTIFICATION-TYPE OBJECTS { sleSlotSystemIndex } STATUS current DESCRIPTION "This trap indicates the slot temperature power cut off" ::= { dasanEvents 445 } slotTemperPowerCutOffCleared NOTIFICATION-TYPE OBJECTS { sleSlotSystemIndex } STATUS current DESCRIPTION "This trap indicates the slot temperature power cut off is cleared" ::= { dasanEvents 446 } gponOnuAuthErrorReasonUpdated NOTIFICATION-TYPE OBJECTS { sleGponOltId, sleGponOnuId, sleGponOnuAuthOnuErrorReason } STATUS current DESCRIPTION "This trap indicates GPON ONU authentication error reason is updated" ::= { dasanEvents 461 } ponRegErr NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon registration is not ok" ::= { dasanEvents 501 } ponBadEncryptionKey NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon encryption key is bad" ::= { dasanEvents 502 } ponLloidMismatch NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon LLOID is mismatched" ::= { dasanEvents 503 } ponTooManyOnu NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon has too many of ONU" ::= { dasanEvents 504 } ponDyingGasp NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon dying GASP" ::= { dasanEvents 505 } ponRegister NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon is registered" ::= { dasanEvents 506 } ponDeregister NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon is deregistered" ::= { dasanEvents 507 } ponLastOnuDeregister NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the last ONU is deregistered" ::= { dasanEvents 508 } ponCableDown NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon cable is down" ::= { dasanEvents 509 } ponCableDownRecover NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon cable down is recovered" ::= { dasanEvents 510 } ponFirstRegistration NOTIFICATION-TYPE OBJECTS { sysDescr, dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the first pon registration" ::= { dasanEvents 511 } ponOntLinkUp NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the ont link up" ::= { dasanEvents 512 } ponOltOnuDown NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the Onu down" ::= { dasanEvents 513 } ponHealthCheckErr NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon health check error" ::= { dasanEvents 514 } ponRegisterModeChange NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon register mode is changed" ::= { dasanEvents 515 } ponOpticSignalErr NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon optic signal error" ::= { dasanEvents 516 } ponOpticSignalErrRecover NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon optic signal error is recovered" ::= { dasanEvents 517 } ponOverVolSigErr NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon over volatage signal error" ::= { dasanEvents 518 } ponOverVolSigErrRecover NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon over volatage signal error is recovered" ::= { dasanEvents 519 } ponOnuRssiInfoErr NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the Onu RSSI information error" ::= { dasanEvents 520 } ponOnuRssiInfoErrCleared NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the Onu RSSI information error is cleard" ::= { dasanEvents 521 } ponOnuCrcUpAlarmErr NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the ONU CRC up alarm error" ::= { dasanEvents 522 } ponOnuCrcUpAlarmErrCleared NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the ONU CRC up alarm error is cleared" ::= { dasanEvents 523 } ponOnuCrcDownAlarmErr NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the ONU CRC down alarm error" ::= { dasanEvents 524 } ponOnuCrcDownAlarmErrCleared NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the ONU CRC down alarm error is cleared" ::= { dasanEvents 525 } ponOnuTooFrequentlyRegErr NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the ONU is registered too frequently." ::= { dasanEvents 526 } ponOnuTooFrequentlyRegErrCleared NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the ONU registration frequently error is cleared." ::= { dasanEvents 527 } ponOnuOpticPowerAlarmErr NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon ONU optic power alarm error" ::= { dasanEvents 528 } ponOnuOpticPowerAlarmErrCleared NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon ONU optic power alarm error is cleared" ::= { dasanEvents 529 } ponOnuDcVoltageAlarmErr NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon ONU DC voltage alarm error" ::= { dasanEvents 530 } ponOnuDcVoltageAlarmErrCleared NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon ONU DC voltage alarm error is cleared" ::= { dasanEvents 531 } ponOnuLoopingAlarmErr NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon ONU looping alarm error" ::= { dasanEvents 532 } ponOnuLoopingAlarmErrCleared NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the pon ONU looping alarm error is cleared" ::= { dasanEvents 533 } ponDetectRogueOnu NOTIFICATION-TYPE OBJECTS { sysDescr, dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the Rogue ONU detection." ::= { dasanEvents 534 } ponDetectRogueOnuCleared NOTIFICATION-TYPE OBJECTS { sysDescr, dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the Rogue ONU detection is cleared." ::= { dasanEvents 535 } ponDetectRogueOnuPowerOff NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the Rogue ONU power off is detected." ::= { dasanEvents 536 } ponDetectRogueOnuDeregisterSuccess NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the Rogue ONU deregister success is detected" ::= { dasanEvents 537 } ponDectectRogueOnuFoundFailed NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the Rogue ONU found fail is detected." ::= { dasanEvents 538 } ponDectectRogueOnuTurn NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the Rogue ONU turn is detected." ::= { dasanEvents 539 } ponOltStandbyRxpowerOverHigh NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the Olt standby RX power is over high threshold" ::= { dasanEvents 540 } ponOltStandbyRxpowerUnderLow NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the Olt standby RX power is under low threshold" ::= { dasanEvents 541} ponOltRedundancyPortDown NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the Olt redundancy port is down" ::= { dasanEvents 542} ponOltRedundancyRxpower NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the Olt redundancy RXpower" ::= { dasanEvents 543} ponOnuBcastStormLlidUpErr NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the broadcast storm llid up error" ::= { dasanEvents 544} ponOnuBcastStormLlidUpErrCleared NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the broadcast storm llid up error is cleared" ::= { dasanEvents 545} ponOnuBcastStormLlidDownErr NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the broadcast storm llid down error" ::= { dasanEvents 546} ponOnuBcastStormLlidDownErrCleared NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the broadcast storm llid down error is cleared" ::= { dasanEvents 547} ponOnuBcastStormUniUpErr NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the broadcast storm UNI up error" ::= { dasanEvents 548} ponOnuBcastStormUniUpErrCleared NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the broadcast storm Uni up error is cleared" ::= { dasanEvents 549} ponOnuReset NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates Pon ONU reset" ::= { dasanEvents 550} ponOnuLifLcErrAlarmErr NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates Pon ONU LIF Error" ::= { dasanEvents 551} ponOnuLifLcErrAlarmErrCleared NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates Pon ONU LIF Error is cleared" ::= { dasanEvents 552} ponOltResetPonMac NOTIFICATION-TYPE OBJECTS { sleEponOltIndex } STATUS current DESCRIPTION "This trap indicates Pon OLT MAC reset" ::= { dasanEvents 561} ponOltRedSwitchover NOTIFICATION-TYPE OBJECTS { sleEponOltRedundancyGroupID, sleEponOltRedundancyMaster, sleEponOltRedundancyMasteStatus, sleEponOltRedundancySlave, sleEponOltRedundancySlaveStatus, sleEponOltRedundancyLastReason } STATUS current DESCRIPTION "This trap indicates the OLT redundancy switchover" ::= { dasanEvents 581} ponOltRedGroupCreated NOTIFICATION-TYPE OBJECTS { sleEponOltRedundancyGroupID, sleEponOltRedundancyMaster, sleEponOltRedundancySlave } STATUS current DESCRIPTION "This trap indicates the OLT redundancy group is created" ::= { dasanEvents 582} ponOltRedGroupDeleted NOTIFICATION-TYPE OBJECTS { sleEponOltRedundancyGroupID, sleEponOltRedundancyMaster, sleEponOltRedundancySlave } STATUS current DESCRIPTION "This trap indicates the OLT redundancy group is deleted" ::= { dasanEvents 583} ponOltRedTriggerChanged NOTIFICATION-TYPE OBJECTS { sleEponOltRedundancyGroupID, sleEponOltRedundancyMaster, sleEponOltRedundancySlave, sleEponOltRedundancyTriggerLos, sleEponOltRedundancyTriggerManual, sleEponOltRedundancyTriggerSlot, sleEponOltRedundancyTriggerEponMac } STATUS current DESCRIPTION "This trap indicates the OLT redundancy trigger is changed" ::= { dasanEvents 584} ponOltRedDbResyncChanged NOTIFICATION-TYPE OBJECTS { sleEponOltRedundancyGroupID, sleEponOltRedundancyMaster, sleEponOltRedundancyMasteStatus, sleEponOltRedundancySlave, sleEponOltRedundancySlaveStatus } STATUS current DESCRIPTION "This trap indicates the OLT redundancy DB resync is changed" ::= { dasanEvents 585} ponOltRedDbSyncChecked NOTIFICATION-TYPE OBJECTS { sleEponOltRedundancyGroupID, sleEponOltRedundancyMaster, sleEponOltRedundancyMasteStatus, sleEponOltRedundancySlave, sleEponOltRedundancySlaveStatus } STATUS current DESCRIPTION "This trap indicates the OLT redundancy DB sync is checked" ::= { dasanEvents 586} ponOnuRssiWarn NOTIFICATION-TYPE OBJECTS { sleEponOltIndex, sleEponOnuIndex } STATUS current DESCRIPTION "This trap indicates the ONU RSSI warning" ::= { dasanEvents 601} ponOnuRssiWarnCleared NOTIFICATION-TYPE OBJECTS { sleEponOltIndex, sleEponOnuIndex } STATUS current DESCRIPTION "This trap indicates the ONU RSSI warning is cleared" ::= { dasanEvents 602} ponOnuRssiAlarm NOTIFICATION-TYPE OBJECTS { sleEponOltIndex, sleEponOnuIndex } STATUS current DESCRIPTION "This trap indicates the ONU RSSI alarm" ::= { dasanEvents 603} ponOnuRssiAlarmCleared NOTIFICATION-TYPE OBJECTS { sleEponOltIndex, sleEponOnuIndex } STATUS current DESCRIPTION "This trap indicates the ONU RSSI alarm is cleared" ::= { dasanEvents 604} ponOnuRxpowerWarn NOTIFICATION-TYPE OBJECTS { sleEponOltIndex, sleEponOnuIndex } STATUS current DESCRIPTION "This trap indicates the ONU RX-power warning" ::= { dasanEvents 605} ponOnuRxpowerWarnCleared NOTIFICATION-TYPE OBJECTS { sleEponOltIndex, sleEponOnuIndex } STATUS current DESCRIPTION "This trap indicates the ONU RX-power warning is cleared" ::= { dasanEvents 606} ponOnuRxpowerAlarm NOTIFICATION-TYPE OBJECTS { sleEponOltIndex, sleEponOnuIndex } STATUS current DESCRIPTION "This trap indicates the ONU RX-power alarm" ::= { dasanEvents 607} ponOnuRxpowerAlarmCleared NOTIFICATION-TYPE OBJECTS { sleEponOltIndex, sleEponOnuIndex } STATUS current DESCRIPTION "This trap indicates the ONU RX-power alarm is cleared" ::= { dasanEvents 608} ponMacTableOverFlow NOTIFICATION-TYPE OBJECTS { sleEponOltIndex, sleEponOnuIndex } STATUS current DESCRIPTION "This trap indicates the Mac table is over Max entry." ::= { dasanEvents 609 } ponMacTableOverFlowCleared NOTIFICATION-TYPE OBJECTS { sleEponOltIndex, sleEponOnuIndex } STATUS current DESCRIPTION "This trap indicates the Mac over max entry is cleared." ::= { dasanEvents 610 } fiberLengthChangedWarningAlarm NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the fiber length is changed" ::= { dasanEvents 611} fiberLengthChangedWarningAlarmCleared NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the fiber length trap is cleared" ::= { dasanEvents 612} ponOnuFrameReplicationAlarm NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the frame is replicated." ::= { dasanEvents 613} ponOnuFrameReplicationAlarmCleared NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelNodeIndex, dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, dsEPonSystemChannelMacAddress } STATUS current DESCRIPTION "This trap indicates the frame is replicated." ::= { dasanEvents 614} ponOnuRxpowerWarnOverHigh NOTIFICATION-TYPE OBJECTS { sleEponOltIndex, sleEponOnuIndex } STATUS current DESCRIPTION "This trap indicates the ONU RX-power high over warning" ::= { dasanEvents 615} ponOnuRxpowerWarnOverHighCleared NOTIFICATION-TYPE OBJECTS { sleEponOltIndex, sleEponOnuIndex } STATUS current DESCRIPTION "This trap indicates the ONU RX-power high over warning is cleared" ::= { dasanEvents 616} ponOnuRxpowerWarnUnderLow NOTIFICATION-TYPE OBJECTS { sleEponOltIndex, sleEponOnuIndex } STATUS current DESCRIPTION "This trap indicates the ONU RX-power low under warning" ::= { dasanEvents 617} ponOnuRxpowerWarnUnderLowCleared NOTIFICATION-TYPE OBJECTS { sleEponOltIndex, sleEponOnuIndex } STATUS current DESCRIPTION "This trap indicates the ONU RX-power low under warning is cleared" ::= { dasanEvents 618} ponOnuRxpowerAlarmOverHigh NOTIFICATION-TYPE OBJECTS { sleEponOltIndex, sleEponOnuIndex } STATUS current DESCRIPTION "This trap indicates the ONU RX-power high over alarm" ::= { dasanEvents 619} ponOnuRxpowerAlarmOverHighCleared NOTIFICATION-TYPE OBJECTS { sleEponOltIndex, sleEponOnuIndex } STATUS current DESCRIPTION "This trap indicates the ONU RX-power high over alarm is cleared" ::= { dasanEvents 620} ponOnuRxpowerAlarmUnderLow NOTIFICATION-TYPE OBJECTS { sleEponOltIndex, sleEponOnuIndex } STATUS current DESCRIPTION "This trap indicates the ONU RX-power low under alarm" ::= { dasanEvents 621} ponOnuRxpowerAlarmUnderLowCleared NOTIFICATION-TYPE OBJECTS { sleEponOltIndex, sleEponOnuIndex } STATUS current DESCRIPTION "This trap indicates the ONU RX-power low under alarm is cleared" ::= { dasanEvents 622} ponOnuUniLinkDown NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, sleEponOnuPortIndex } STATUS current DESCRIPTION "This trap indicates the Onu Uni link is down." ::= { dasanEvents 623} ponOnuUniLinkUp NOTIFICATION-TYPE OBJECTS { dsEPonSystemChannelPortIndex, dsEPonSystemChannelId, sleEponOnuPortIndex } STATUS current DESCRIPTION "This trap indicates the Onu Uni link is up." ::= { dasanEvents 624} END -- -- dasan-notification.mib --