-- -- sle-faultmgmt-mib.mib -- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88 -- Tuesday, April 12, 2016 at 17:15:30 -- SLE-FAULTMGMT-MIB DEFINITIONS ::= BEGIN IMPORTS sleMgmt FROM DASAN-SMI SleControlStatusType, SleControlRequestResultType FROM SLE-TC-MIB OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF TimeTicks, IpAddress, Integer32, Unsigned32, Gauge32, Counter32, Counter64, BITS, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI MacAddress, TimeStamp, TEXTUAL-CONVENTION FROM SNMPv2-TC; sleFaultMgmt MODULE-IDENTITY LAST-UPDATED "201008130000Z" -- August 13, 2010 at 00:00 GMT ORGANIZATION " DASAN Networks" CONTACT-INFO " " DESCRIPTION "The MIB module representing multiple logical entities for the SLE alarm management. " REVISION "190412080000Z" -- December 08, 1904 at 00:00 GMT DESCRIPTION " " ::= { sleMgmt 4 } -- -- Textual conventions -- SpecificNum ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Description." SYNTAX INTEGER { portDown(1), portUp(2), portRemoved(3), portInstalled(4), powerFail(5), powerOK(6), powerRemoved(7), powerInstalled(8), fanFail(9), fanOK(10), fanRemoved(11), fanInstalled(12), moduleRemoved(13), moduleInstalled(14), systemRestart(15), systemStart(16), broadcastOver(17), broadcastUnder(18), cpuOverLoad(19), cpuUnderLoad(20), memoryOverUsed(21), memoryUnderUsed(22), portOverThreshold(23), portUnderThreshold(24), temperatureHigh(25), temperatureLow(26), mfgdBlocked(27), mfgdReleased(28), ipConflict(29), ipUnconflict(30), dhcpLeaseShortage(31), dhcpLeaseSufficient(32), dhcpOccuredIllegalEntry(33), dhcpRemovedIllegalEntry(34), rmonAlarmRising(35), rmonAlarmNoRising(36), rmonAlarmFalling(37), rmonAlarmNoFalling(38), bpduGuardDisabled(39), rootGuardDisabled(40), portSecurity(41), userLogin(42), userLogout(43), systemWarmStart(44), igmpGroupJoined(51), igmpGroupLeaved(52), dhcpIpaddressBound(53), dhcpIpaddressFree(54), doorOpened(55), doorClosed(56), powerModeChangedPowerToBattery(57), powerModeChangedBatteryToPower(58), batterylowcapacity(59), batterynormalcapacity(60), batteryhighTemperature(61), batterynormalTemperature(62), authenticationFail(63), authenticationNoFail(64), psuAcHighTemperature(65), psuAcNormalTemperature(66), batteryRemoved(67), batteryEquipped(68), batteryLowVoltage(69), batteryNormalVoltage(70), adminAccessLogin(71), adminAccessLogout(72), cfgdBlocked(73), cfgdReleased(74), sfgdBlocked(75), sfgdReleased(76), swWatchdogAbnomalState(77), swWatchdogNomalState(78), swWatchdogDetectError(79), swWatchdogClearError(80), ppsControlBlocked(81), ppsControlReleased(82), gotDMITempHighOverAlarm(83), gotDMITempHighFallAlarm(84), gotDMITempLowOverAlarm(85), gotDMITempLowFallAlarm(86), gotDMITempHighOverWarning(87), gotDMITempHighFallWarning(88), gotDMITempLowOverWarning(89), gotDMITempLowFallWarning(90), gotDMIVolHighOverAlarm(91), gotDMIVolHighFallAlarm(92), gotDMIVolLowOverAlarm(93), gotDMIVolLowFallAlarm(94), gotDMIVolHighOverWarning(95), gotDMIVolHighFallWarning(96), gotDMIVolLowOverWarning(97), gotDMIVolLowFallWarning(98), gotDMITxBiasHighOverAlarm(99), gotDMITxBiasHighFallAlarm(100), gotDMITxBiasLowOverAlarm(101), gotDMITxBiasLowFallAlarm(102), gotDMITxBiasHighOverWarning(103), gotDMITxBiasHighFallWarning(104), gotDMITxBiasLowOverWarning(105), gotDMITxBiasLowFallWarning(106), gotDMITxPowerHighOverAlarm(107), gotDMITxPowerHighFallAlarm(108), gotDMITxPowerLowOverAlarm(109), gotDMITxPowerLowFallAlarm(110), gotDMITxPowerHighOverWarning(111), gotDMITxPowerHighFallWarning(112), gotDMITxPowerLowOverWarning(113), gotDMITxPowerLowFallWarning(114), gotDMIRxPowerHighOverAlarm(115), gotDMIRxPowerHighFallAlarm(116), gotDMIRxPowerLowOverAlarm(117), gotDMIRxPowerLowFallAlarm(118), gotDMIRxPowerHighOverWarning(119), gotDMIRxPowerHighFallWarning(120), gotDMIRxPowerLowOverWarning(121), gotDMIRxPowerLowFallWarning(122), nosRemoteUpgradeRequest(123), nosRemoteUpgradeSuccess(124), nosRemoteUpgradeFailAbort(125), nosRemoteUpgradeFailHeaderError(126), nosRemoteUpgradeFailDownloadError(127), nosRemoteUpgradeFailFlashError(128), nosRemoteUpgradeStart(129), systemDyingGasp(130), remoteOamDyingGasp(131), remoteOamDyingGaspRestoration(132), cliHistory(133), cliHistoryNo(134), ntpConnectionFail(135), nmsConnectionTypeChanged(137), fanSpeedFallUnderThreshold(138), fanSpeedRisingOverThreshold(139), userLoginFail(140), temperatureHighContinued(142), swWatchdogInetAbnormalState(150), swWatchdogInetNormalState(151), swWatchdogInetDetectError(152), swWatchdogInetClearError(153), swWatchdogPonAbnormalState(154), swWatchdogPonNormalState(155), swWatchdogPonDetectError(156), swWatchdogPonClearError(157), arpInspectInvalid(158), clockModuleRemoved(159), clockModuleInstalled(160), clockModuleInitFail(161), clockModuleInitOk(162), cliHistoryLog(163), cliHistoryLogNo(164), slotActionEvent(165), slotStateChange(166), interfaceAdminDown(167), interfaceAdminUp(168), slotPowerMonAbnormal(169), slotPowerMonNormal(170), slotErrorLEDChanged(171), bfdSessionStateChanged(172), clockModuleOPModeChanged(173), clockModuleRefChanged(174), clockModuleInSrcStatusChanged(175), clockModuleInSrcAISStatusChanged(176), clockModuleInSrcLoSStatusChanged(177), clockModuleInSrcLSDCStatusChanged(178), clockModuleInSrcNtrClockChanged(179), portRxOverThreshold(181), portRxUnderThreshold(182), portTxOverThreshold(183), portTxUnderThreshold(184), cpuPpsOverThreshold(185), cpuPpsUnderThreshold(186), pairFanPowerOff(191), pairFanPowerOn(192), slotHealthStatusTimeout(199), slotHealthStatusTimeoutCleared(200), advaTemperature(201), advaTemperatureNo(202), advaPSUFailure(203), advaPSUFailureNo(204), advaFanFailure(205), advaFanFailureNo(206), advaInterfaceReceiveFailure(207), advaInterfaceReceiveFailureNo(208), advaInterfaceOpticalThreshold(209), advaInterfaceOpticalThresholdNo(210), advaInterfaceTransmitFault(211), advaInterfaceTransmitFaultNo(212), advaInterfaceMisconfiguration(213), advaInterfaceMisconfigurationNo(214), advaInterfaceSFPMismatch(215), advaInterfaceSFPMismatchNo(216), advaVoltageLow(217), advaVoltageLowNo(218), advaVoltageHigh(219), advaVoltageHighNo(220), criticalAlarmLedOn(251), criticalAlarmLedOff(252), majorAlarmLedOn(253), majorAlarmLedOff(254), minorAlarmLedOn(255), minorAlarmLedOff(256), systemTemperPowerCutOff(291), systemTemperPowerCutoffCleared(292), slotTemperPowerCutOff(294), erpDomainLotp(301), erpDomainLotpNo(302), erpDomainULotp(303), erpDomainULotpNo(304), erpDomainMultipleRM(305), erpDomainMultipleRMNo(306), erpDomainRMNodeReacheablity(307), erpDomainRMNodeReacheablityNo(308), startupConfigLoadEnded(391), eponOnuDeregister(401), eponOnuRegister(402), eponOnuRegistrationError(403), eponOnuNoRegistrationError(404), eponBadEncryptionKey(405), eponNoBadEncryptionKey(406), eponLlidMistmatch(407), eponNoLlidMismatch(408), eponTooManyRegister(409), eponNoTooManyRegister(410), eponDyingGASP(411), eponNoDyingGASP(412), eponOnuErrFramePeriod(413), eponOnuNoErrFramePeriod(414), eponOnuErrFrame(415), eponOnuNoErrFrame(416), eponOnuErrFrameSecondSummary(417), eponOnuNoErrFrameSecondSummary(418), eponOnuLastOnuDeregister(419), eponOnuNoLastOnuDeregister(420), eponOltCableDown(421), eponOltRecoverCableDown(422), eponOltHealthCheckError(423), eponOnuOpticSignalErr(424), eponOnuRecoverOpticSignalErr(425), standardLinkFault(428), standardLinkFaultCleared(429), lossOfSignal(430), lossOfSignalCleared(431), transmitFail(432), transmitFailCleared(433), macLearningOverflow(434), macLearningOverflowCleared(435), loopback(436), loopbackCleared(437), standardDyinggasp(438), standardDyinggaspCleared(439), externalDyinggasp(440), externalDyinggaspCleared(441), standardCriticalEvent(442), standardCriticalEventCleared(443), externalCriticalEvent(444), externalCriticalEventCleared(445), eponStandbyLos(446), eponStandbyLosCleared(447), eponOnuPingTest(448), eponOnuDmiThresholdTemperOverHighWarn(450), clearEponOnuDmiThresholdTemperOverHighWarn(451), eponOnuDmiThresholdTemperFallLowWarn(452), clearEponOnuDmiThresholdTemperFallLowWarn(453), eponOnuDmiThresholdTemperOverHighAlarm(454), clearEponOnuDmiThresholdTemperOverHighAlarm(455), eponOnuDmiThresholdTemperFallLowAlarm(456), clearEponOnuDmiThresholdTemperFallLowAlarm(457), eponOnuDmiThresholdVoltageOverHighWarn(458), clearEponOnuDmiThresholdVoltageOverHighWarn(459), eponOnuDmiThresholdVoltageFallLowWarn(460), clearEponOnuDmiThresholdVoltageFallLowWarn(461), eponOnuDmiThresholdVoltageOverHighAlarm(462), clearEponOnuDmiThresholdVoltageOverHighAlarm(463), eponOnuDmiThresholdVoltageFallLowAlarm(464), clearEponOnuDmiThresholdVoltageFallLowAlarm(465), eponOnuDmiThresholdTxbiasOverHighWarn(466), clearEponOnuDmiThresholdTxbiasOverHighWarn(467), eponOnuDmiThresholdTxbiasFallLowWarn(468), clearEponOnuDmiThresholdTxbiasFallLowWarn(469), eponOnuDmiThresholdTxbiasOverHighAlarm(470), clearEponOnuDmiThresholdTxbiasOverHighAlarm(471), eponOnuDmiThresholdTxbiasFallLowAlarm(472), clearEponOnuDmiThresholdTxbiasFallLowAlarm(473), eponOnuDmiThresholdTxpowerOverHighWarn(474), clearEponOnuDmiThresholdTxpowerOverHighWarn(475), eponOnuDmiThresholdTxpowerFallLowWarn(476), clearEponOnuDmiThresholdTxpowerFallLowWarn(477), eponOnuDmiThresholdTxpowerOverHighAlarm(478), clearEponOnuDmiThresholdTxpowerOverHighAlarm(479), eponOnuDmiThresholdTxpowerFallLowAlarm(480), clearEponOnuDmiThresholdTxpowerFallLowAlarm(481), eponOnuDmiThresholdRxpowerOverHighWarn(482), clearEponOnuDmiThresholdRxpowerOverHighWarn(483), eponOnuDmiThresholdRxpowerFallLowWarn(484), clearEponOnuDmiThresholdRxpowerFallLowWarn(485), eponOnuDmiThresholdRxpowerOverHighAlarm(486), clearEponOnuDmiThresholdRxpowerOverHighAlarm(487), eponOnuDmiThresholdRxpowerFallLowAlarm(488), clearEponOnuDmiThresholdRxpowerFallLowAlarm(489), eponDetectRouge(490), clearEpoonDetectRouge(491), eponDetectRougeOnuPowerOff(492), eponDetectRougeOnuPowerOffFailed(493), eponDetectRougeOnuDeregisterSuccess(494), eponDetectRougeOnuDeregisterFailed(495), eponDetectRougeOnuFoundFailed(496), eponOltRedundancyDetectRxpower(497), clearEponOltRedundancyDetectRxpower(498), eponOltRedundancySwitchoverReasonForce(499), eponOltRedundancySwitchoverReasonLos(500), autoCLIStart(501), autoCLINoStart(502), autoCLIComplete(503), autoCLINoComplete(504), autoCLIRemoveOutputFile(505), autoCLINoRemoveOutputFile(506), autoResetSystem(507), autoResetNoSystem(508), autoResetPingReplyLoss(509), autoResetNoPingReplyLoss(510), autoResetMemoryLeakDetect(511), autoResetNoMemoryLeakDetect(512), loopDetectBlocked(551), loopDetectUnBlockedByExpireTimer(552), loopDetectUnBlockedByLinkDown(553), loopDetectUnBlockedByClearCmd(554), oamRemoteTestLoopback(562), arulePacketDropDetect(601), arulePacketDropRelease(602), autoCpeUpgradeStart(605), autoCpeUpgradeFail(607), autoCpeUpgradeSuccess(609), batteryUnderTemper(611), batteryTemperUnderToNormal(612), batteryCellAbnormal(613), batteryCellNormal(614), batteryCellTestChargeStarted(615), batteryCellTestChargeFinished(616), batteryAcPowerFault(617), batteryAcPowerOk(618), bME1CardNoDetect(620), clearBME1CardNoDetect(621), bME1CardAFEerror(622), clearBME1CardAFEerror(623), bME1CardIFEerror(624), clearBME1CardIFEerror(625), bME1CardFWerror(626), clearBME1CardFWerror(627), bME1CardPROVerror(628), clearBME1CardPROVerror(629), bME1CrashDetect(630), clearBME1CrashDetect(631), bME2CardNoDetect(632), clearBME2CardNoDetect(633), bME2CardAFEerror(634), clearBME2CardAFEerror(635), bME2CardIFEerror(636), clearBME2CardIFEerror(637), bME2CardFWerror(638), clearBME2CardFWerror(639), bME2CardPROVerror(640), clearBME2CardPROVerror(641), bME2CrashDetect(642), clearBME2CrashDetect(643), bME3CardNoDetect(644), clearBME3CardNoDetect(645), bME3CardAFEerror(646), clearBME3CardAFEerror(647), bME3CardIFEerror(648), clearBME3CardIFEerror(649), bME3CardFWerror(650), clearBME3CardFWerror(651), bME3CardPROVerror(652), clearBME3CardPROVerror(653), bME3CrashDetect(654), clearBME3CrashDetect(655), powerFromBattery(656), clearPowerFromBattery(657), invalidBatteryStatus(658), clearInvalidBatteryStatus(659), batteryChargeLow(660), clearBatteryChargeLow(661), batteryNotPresent(662), clearBatteryNotPresent(663), voltageLow(664), clearVoltageLow(665), tempOverThreshold(666), clearTempOverThreshold(667), tempUnderThreshold(668), clearTempUnderThreshold(669), cpuOverThreshold(670), clearCpuOverThreshold(671), trafficOverload(672), clearTrafficOverload(673), gEPONModuleNotDetect(674), clearGEPONModuleNotDetect(675), gEPONPortOperationDown(676), clearGEPONPortOperationDown(677), gEPONNoIncomingTraffic(678), clearGEPONNoIncomingTraffic(679), processCrashDetect(680), clearProcessCrashDetect(681), memoryLeakDetect(682), clearMemoryLeakDetect(683), memoryCorrupDetect(684), clearMemoryCorrupDetect(685), memoryLowDetect(686), clearMemoryLowDetect(687), dataLineerror(688), clearDataLineerror(689), addressLineerror(690), clearAddressLineerror(691), chipsetNotDetcet(692), clearChipsetNotDetcet(693), pciBuserror(694), clearPciBuserror(695), securityAdminConnect(696), clearSecurityAdminConnect(697), oNUPowerDown(698), clearONUPowerDown(699), oNUNotRegister(700), clearONUNotRegister(701), oNTOpticPre(702), clearONTOpticPre(703), writeMemroyFailSeveralTimes(721), writeMemroyFailSeveralTimesCleared(722), switchoverInitiated(800), switchoverDone(801), boardChangeState(802), redConfigurationMisMatch(803), aiuAlarmInput1(851), aiuAlarmInput1Cleared(852), aiuAlarmInput2(853), aiuAlarmInput2Cleared(854), aiuAlarmInput3(855), aiuAlarmInput3Cleared(856), aiuAlarmInput4(857), aiuAlarmInput4Cleared(858), aiuSlotUninstalled(859), aiuSlotInstalled(860), gponNoAuthCBU(901), gponDuplicateONU(902), gponDyingGasp(903), gponUpgradeComplete(904), gponDeregistered(905), gponRegistered(906), gponRogueOnu(907), gponOnuBatteryEvent(908), clearGponOnuBetteryEvent(909), gponOnuPortOperStatus(910), gponTransceiverChanged(911), gponOltLosOn(912), gponOltLosOff(913), gponOltLosiOn(914), gponOltLosiOff(915), gponDyingGaspOn(916), gponDyingGaspOff(917), gponOntOSUpgradeStatus(918), gponOntBLUpgradeStatus(919), gponOltRxPowerLoss(920), gponOltRxPowerDetected(921), gponOnuTemperatureHighOverThreshold(922), gponOnuTemperatureHighFallThreshold(923), gponOnuTemperatureLowOverThreshold(924), gponOnuTemperatureLowFallThreshold(925), gponOnuCpuOverThreshold(926), gponOnuCpuFallThreshold(927), gponOnuMemoryOverThreshold(928), gponOnuMemoryFallThreshold(929), gponOnuI2cFail(930), gponOnuRxOpticLowThreshAlarmOn(931), gponOnuRxOpticLowThreshAlarmOff(932), gponOnuRxOpticHighThreshAlarmOn(933), gponOnuRxOpticHighThreshAlarmOff(934), gponOltLOFIOn(935), gponOltLOFIOff(936), gponOltDOWOn(937), gponOltDOWOff(938), gponOltSFOn(939), gponOltSFOff(940), gponOltSDOn(941), gponOltSDOff(942), gponOltLCDGIOn(943), gponOltLCDGIOff(944), gponOltRDOn(945), gponOltRDOff(946), gponOltSUFOn(947), gponOltSUFOff(948), gponOltLOAOn(949), gponOltLOAOff(950), gponOltLOAMIOn(951), gponOltLOAMIOff(952), gponOltMEMOn(953), gponOltMEMOff(954), gponOltPEEOn(955), gponOltPEEOff(956), gponOltPSTOn(957), gponOltPSTOff(958), gponOltERROn(959), gponOltERROff(960), gponOltREIOn(961), gponOltREIOff(962), gponAntiSpoofingDupPortOn(963), gponAntiSpoofingDupPortOff(964), gponRedundancySwitchOver(965), gponDuplicatedRangingResponse(966), gponOnuPortOpticModuleRemove(967), gponOnuPortOpticModuleInstall(968), gponOnuOMCCProblemDetected(969), gponOnuOMCCProblemCleared(970), gponOltFixedTcontAlarmOn(971), gponOltFixedTcontAlarmOff(972), gponOltDynamicTcontAlarmOn(973), gponOltDynamicTcontAlarmOff(974), gponOltPortCountAlarmOn(975), gponOltPortCountAlarmOff(976), gponOltCableDownAlarmOn(977), gponOltCableDownAlarmOff(978), gponOltDeactiveMonitorAlarmOn(979), gponOltDeactiveMonitorAlarmOff(980), gponOltDfiOn(981), gponOltDfiOff(982), gponOltTransceiverPortChanged(984), gponOnuPortOperStatusDown(985), gponOnuPortOperStatusUp(986), gponOltRxPowerHighOver(987), gponOltRxPowerHighCleared(988), gponOltRxPowerLowUnder(989), gponOltRxPowerLowCleared(990), oamRapsEastPortStatusChanged(1001), oamRapsWestPortStatusChanged(1002), oamURNodePortStatusChanged(1003), oamRemoteLlcfLinkDown(1008), oamRemoteLlcfLinkUp(1009), oamInterfaceStatusChanged(1010), oamMepRDIDetected(1011), oamMepRDICleared(1012), oamMepLOCDetected(1013), oamMepLOCCleared(1014), oamMepUNPDetected(1015), oamMepUNPCleared(1016), oamMepUNMDetected(1017), oamMepUNMCleared(1018), oamMepMMGDetected(1019), oamMepMMGCleared(1020), oamMepUNLDetected(1021), oamMepUNLCleared(1022), oamMepAISDetected(1023), oamMepAISCleared(1024), oamMepLCKDetected(1025), oamMepLCKCleared(1026), oamMepMISSINGDetected(1027), oamMepMISSINGCleared(1028), voipPortStatusEnabled(1051), voipPortStatusDisabled(1052), emLogDefectCPUHighOver(1101), emLogDefectCPUHighUnder(1102), emLogTemperHighOver(1103), emLogTemperHighUnder(1104), emLogTemperLowUnder(1105), emLogTemperLowOver(1106), emLogMemLowUnder(1107), emLogMemLowOver(1108), emLogFanFail(1109), emLogFanFailCleared(1110), emLogPhyCRCFail(1111), emLogPhyCRCFailCleared(1112), emLogPhyDetectFail(1113), emLogPhyDetectFailCleared(1114), emLogSFUMateInitFail(1115), emLogSFUMateInitFailCleared(1116), emLogDaemonHealthBad(1117), emLogDaemonHealthBadCleared(1118), emLogGPIURavenLinkDown(1119), emLogGPIURavenLinkDownCleared(1120), emLogRPMLow(1121), emLogRPMLowCleared(1122), emLogNAKError(1123), emLogNAKErrorCleared(1124), snmpAllConfCleared(1141), slotNosUpgradeStart(1151), slotNosUpgradeEnd(1152), autonegoMissmatedSpeed(1171), autonegoMissmatedDuplex(1172), autonegoMismatched(1174), dmiTempHighOverDurationAlarmOld(1201), dmiTempLowFallDurationAlarmOld(1202), dmiTempHighOverDurationWarningOld(1203), dmiTempLowFallDurationWarningOld(1204), dmiVolHighOverDurationAlarmOld(1205), dmiVolLowFallDurationAlarmOld(1206), dmiVolHighOverDurationWarningOld(1207), dmiVolLowFallDurationWarningOld(1208), dmiTxBiasHighOverDurationAlarmOld(1209), dmiTxBiasLowFallDurationAlarmOld(1210), dmiTxBiasHighOverDurationWarningOld(1211), dmiTxBiasLowFallDurationWarningOld(1212), dmiTxPowerHighOverDurationAlarmOld(1213), dmiTxPowerLowFallDurationAlarmOld(1214), dmiTxPowerHighOverDurationWarningOld(1215), dmiTxPowerLowFallDurationWarningOld(1216), dmiRxPowerHighOverDurationAlarmOld(1217), dmiRxPowerLowFallDurationAlarmOld(1218), dmiRxPowerHighOverDurationWarningOld(1219), dmiRxPowerLowFallDurationWarningOld(1220), attackGuard(1221), attackGuardNo(1222), activeLinkDown(1223), activeLinkDownNo(1224), activeLinkUp(1225), activeLinkUpNo(1226), redundantLinkDown(1227), redundantLinkDownNo(1228), redundantLinkUp(1229), redundantLinkUpNo(1230), inputErrorThreshold(1231), inputErrorThresholdNo(1232), overSizeFrameThreshold(1233), overSizeFrameThresholdNo(1234), configLoadFail(1235), configLoadFailNo(1236), nosLoadFail(1237), nosLoadFailNo(1238), securityViolation(1239), securityViolationNo(1240), selfTestCompleted(1241), selfTestCompletedNo(1242), risingAlarm(1243), risingAlarmNo(1244), fallingAlarm(1245), fallingAlarmNo(1246), newRoot(1247), newRootNo(1248), topologyChange(1249), topologyChangeNo(1250), broadcastStormStart(1251), broadcastStormStartNo(1252), broadcastStormEnd(1253), broadcastStormEndNo(1254), duplicateMac(1255), duplicateMacNo(1256), trapLog(1257), trapLogNo(1258), scriptLoadFail(1259), scriptLoadFailNo(1260), monitorEvent(1261), monitorEventNo(1262), powerDetectFail(1263), powerDetectOk(1264), underSizeFrameThreshold(1265), underSizeFrameThresholdNo(1266), runtFrameThreshold(1267), runtFrameThresholdNo(1268), dyingGasp(1269), dyingGaspNo(1270), voipPortStatusEnable(1271), voipPortStatusDisable(1272), fanStop(1281), fanRun(1282), mllcfLinkDown(1301), mllcfLinkUp(1302), gponOnuAniVoltageLowThreshAlarmOn(1331), gponOnuAniVoltageLowThreshAlarmOff(1332), gponOnuAniVoltageHighThreshAlarmOn(1333), gponOnuAniVoltageHighThreshAlarmOff(1334), gponOnuAniTemperatureLowThreshAlarmOn(1335), gponOnuAniTemperatureLowThreshAlarmOff(1336), gponOnuAniTemperatureHighThreshAlarmOn(1337), gponOnuAniTemperatureHighThreshAlarmOff(1338), gponOnuAniTxBiasLowThreshAlarmOn(1339), gponOnuAniTxBiasLowThreshAlarmOff(1340), gponOnuAniTxBiasHighThreshAlarmOn(1341), gponOnuAniTxBiasHighThreshAlarmOff(1342), gponOnuAniTxpowerLowThreshAlarmOn(1343), gponOnuAniTxpowerLowThreshAlarmOff(1344), gponOnuAniTxpowerHighThreshAlarmOn(1345), gponOnuAniTxpowerHighThreshAlarmOff(1346), gponOnuServiceOpModeAlarm(1347), gponOnuServiceOpModeAlarmCleared(1348), gponOnuAuthErrorReasonUpdated(1350), portThresholdTxOverAlarm(1351), portThresholdTxOverAlarmCleared(1352), portThresholdTxOverWarn(1353), portThresholdTxOverWarnCleared(1354), portThresholdRxOverAlarm(1355), portThresholdRxOverAlarmCleared(1356), portThresholdRxOverWarn(1357), portThresholdRxOverWarnCleared(1358), tempThresholdHighOverAlarm(1361), tempThresholdHighOverAlarmCleared(1362), tempThresholdLowOverAlarm(1363), tempThresholdLowOverAlarmCleared(1364), tempThresholdHighOverWarn(1365), tempThresholdHighOverWarnCleared(1366), tempThresholdLowOverWarn(1367), tempThresholdLowOverWarnCleared(1368), moduleDmiReadError(1381), moduleDmiReadErrorCleared(1382), stormControlRxOver(1391), stormControlRxOverCleared(1392), rmonCrcAlignErrorRising(1401), rmonCrcAlignErrorRisingCleared(1402), rmonJabberRising(1403), rmonJabberRisingCleared(1404), rmonOversizePacketRising(1405), rmonOversizePacketRisingCleared(1406), rmonUndersizePacketRising(1407), rmonUndersizePacketRisingCleared(1408), rmonFragmentRising(1409), rmonFragmentRisingCleared(1410), rmonDropEventRising(1411), rmonDropEventRisingCleared(1412), rmonCollisionRising(1413), rmonCollisionRisingCleared(1414), rmonIfInDiscardsRising(1415), rmonIfInDiscardsRisingCleared(1416), rmonIfInErrosRising(1417), rmonIfInErrosRisingCleared(1418), rmonIfOutDiscardsRising(1419), rmonIfOutDiscardsRisingCleared(1420), rmonIfOutErrosRising(1421), rmonIfOutErrosRisingCleared(1422), rmonIfInPauseFrameRising(1423), rmonIfInPauseFrameRisingCleared(1424), rmonIfOutPauseFrameRising(1425), rmonIfOutPauseFrameRisingCleared(1426), rmonQueueTransmitRising(1427), rmonQueueTransmitRisingCleared(1428), rmonQueueDropRising(1429), rmonQueueDropRisingCleared(1430), eponOltRedundancySwitchoverReasonSlotRemove(1500), eponOltRedundancySwitchoverReasonSlotRestart(1501), eponOltRedundancySwitchoverReasonAutoDetect(1502), eponOltRedundancySwitchoverReasonWtrDetect(1503), eponOnuCrcUpStreamAlarmErr(1504), eponOnuCrcUpStreamAlarmErrClean(1505), eponOnuTooFrequentlyRegisteredErr(1506), eponOnuTooFrequentlyRegisteredErrClean(1507), eponOnuCrcDownStreamAlarmErr(1508), eponOnuCrcDownStreamAlarmErrClean(1509), eponOnuOpticPowerAlarmErr(1510), eponOnuOpticPowerAlarmErrClean(1511), eponOnuDcVoltageAlarmErr(1512), eponOnuDcVoltageAlarmErrClean(1513), eponOnuLoopingAlarmErr(1514), eponOnuLoopingAlarmErrClean(1515), eponOltRedundancyStandbyOltRxPowerOverHighThresholdAlarm(1516), eponOltRedundancyStandbyOltRxPowerUnderLowThresholdAlarm(1517), eponOnuBroadcastStormLlidUpAlarmErr(1518), eponOnuBroadcastStormLlidUpAlarmErrClean(1519), eponOnuBroadcastStormLlidDnAlarmErr(1520), eponOnuBroadcastStormLlidDnAlarmErrClean(1521), eponOnuBroadcastStormUniUpAlarmErr(1522), eponOnuBroadcastStormUniUpAlarmErrClean(1523), eponDetectRogueOnuTurn(1530), eponDetectRogueOnuTurnClean(1531), eponOnuLoopDetectErr(1532), eponOnuRecoverDetectErr(1533), eponThresholdAlarmLoopDetectErr(1534), eponThresholdAlarmRecoverLoopDetectErr(1535), eponThresholdAlarmOpticAlarmErr(1536), eponThresholdAlarmRecoverOpticAlarmErr(1537), eponThresholdAlarmOverVoltageErr(1538), eponThresholdAlarmRecoverOverVoltageErr(1539), eponOLTSFPModuleInstalled(1540), eponOLTSFPModuleRemoved(1541), eponOnuDailyRxPowerAlarm(1542), fiberLengthChangedWarningAlarm(1561), fiberLengthChangedWarningAlarmCleared(1562), cfmOnuMepRdiCcmDetected(1601), cfmOnuMepRdiCcmCleared(1602), cfmOnuMepMacStatusDetected(1603), cfmOnuMepMacStatusCleared(1604), cfmOnuMepRemoteCcmDetected(1605), cfmOnuMepRemoteCcmCleared(1606), cfmOnuMepErrorCcmDetected(1607), cfmOnuMepErrprCcmCleared(1608), cfmOnuMepXconCcmDetected(1609), cfmOnuMepXconCcmCleared(1610), cfmOnuMepUnexpectedPeriodDetected(1611), cfmOnuMepUnexpectedPeriodCleared(1612), cfmOnuMepAisDetected(1613), cfmOnuMepAisCleared(1614), tcpDosAttack(2001), tcpDosAttackCleared(2002), tcpPortFlooding(2003), tcpPortFloodingCleared(2004), tcpHostRandomFlooding(2005), tcpHostRandomFloodingCleared(2006), tcpHostScanning(2007), tcpHostScanningCleared(2008), ipSppfing(2009), ipSppfingCleared(2010), udpDosAttack(2011), udpDosAttackCleared(2012), udpPortFlooding(2013), udpPortFloodingCleared(2014), udpHostRandomFlooding(2015), udpHostRandomFloodingCleared(2016), udpHostScanning(2017), udpHostScanningCleared(2018), udpIPSppfing(2019), udpIPSppfingCleared(2020), icmpDosAttack(2021), icmpDosAttackCleared(2022), icmpIPSppfing(2023), icmpIPSppfingCleared(2024), icmpHostScanning(2025), icmpHostScanningCleared(2026), arpMacFlooding(2027), arpMacFloodingCleared(2028), arpSpoofing(2029), arpSpoofingCleared(2030), decoySnare(2031), decoySnareCleared(2032), hostScan(2033), hostScanCleared(2034), portScan(2035), portScanCleared(2036), tcpPortScanning(2037), tcpPortScanningCleared(2038), udpPortScanning(2039), udpPortScanningCleared(2040), staticAttack(2041), staticAttackCleared(2042), dmiTempHighOverDurationAlarm(2101), dmiTempHighOverDurationAlarmCleared(2102), dmiTempLowOverDurationAlarm(2103), dmiTempLowOverDurationAlarmCleared(2104), dmiTempHighOverDurationWarning(2105), dmiTempHighOverDurationWarningCleared(2106), dmiTempLowOverDurationWarning(2107), dmiTempLowOverDurationWarningCleared(2108), dmiVolHighOverDurationAlarm(2109), dmiVolHighOverDurationAlarmCleared(2110), dmiVolLowOverDurationAlarm(2111), dmiVolLowOverDurationAlarmCleared(2112), dmiVolHighOverDurationWarning(2113), dmiVolHighOverDurationWarningCleared(2114), dmiVolLowOverDurationWarning(2115), dmiVolLowOverDurationWarningCleared(2116), dmiTxBiasHighOverDurationAlarm(2117), dmiTxBiasHighOverDurationAlarmCleared(2118), dmiTxBiasLowOverDurationAlarm(2119), dmiTxBiasLowOverDurationAlarmCleared(2120), dmiTxBiasHighOverDurationWarning(2121), dmiTxBiasHighOverDurationWarningCleared(2122), dmiTxBiasLowOverDurationWarning(2123), dmiTxBiasLowOverDurationWarningCleared(2124), dmiTxPowerHighOverDurationAlarm(2125), dmiTxPowerHighOverDurationAlarmCleared(2126), dmiTxPowerLowOverDurationAlarm(2127), dmiTxPowerLowOverDurationAlarmCleared(2128), dmiTxPowerHighOverDurationWarning(2129), dmiTxPowerHighOverDurationWarningCleared(2130), dmiTxPowerLowOverDurationWarning(2131), dmiTxPowerLowOverDurationWarningCleared(2132), dmiRxPowerHighOverDurationAlarm(2133), dmiRxPowerHighOverDurationAlarmCleared(2134), dmiRxPowerLowOverDurationAlarm(2135), dmiRxPowerLowOverDurationAlarmCleared(2136), dmiRxPowerHighOverDurationWarning(2137), dmiRxPowerHighOverDurationWarningCleared(2138), dmiRxPowerLowOverDurationWarning(2139), dmiRxPowerLowOverDurationWarningCleared(2140), reloadMateInitiated(2201), reloadMateDone(2202), reloadSIUInitiated(2203), reloadSIUDone(2204) } -- -- Node definitions -- sleFaultMgmtBase OBJECT IDENTIFIER ::= { sleFaultMgmt 1 } sleFaultMgmtBaseGroup OBJECT IDENTIFIER ::= { sleFaultMgmtBase 1 } sleFaultDefaultSeverity OBJECT-TYPE SYNTAX INTEGER { critical(1), major(2), minor(3), warning(4), intermediate(5) } MAX-ACCESS read-only STATUS current DESCRIPTION " The severity of alarm. " ::= { sleFaultMgmtBaseGroup 1 } sleFaultCriteriaSeverity OBJECT-TYPE SYNTAX INTEGER { critical(1), major(2), minor(3), warning(4), intermediate(5) } MAX-ACCESS read-only STATUS current DESCRIPTION " The severity of alarm. " ::= { sleFaultMgmtBaseGroup 2 } sleFaultNotifiyActivity OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-only STATUS current DESCRIPTION " The severity of alarm. " ::= { sleFaultMgmtBaseGroup 3 } sleFaultNextSeqNum OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Sequence number for the alarm synchronization. This value has a number to be used for the next alarm trap." ::= { sleFaultMgmtBaseGroup 4 } sleFaultMgmtBaseControl OBJECT IDENTIFIER ::= { sleFaultMgmtBase 2 } sleFaultControlRequest OBJECT-TYPE SYNTAX INTEGER { setAlarmDefaultSeverity(1), setAlarmCriteriaSeverity(2), setNotificationActivity(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " This attribute identifies the control commands. updateAlarmList: the NE updates entries of alarms in the sleAlarmListTable after having changed alarm severities of alarms (due to change profile pointers in managed entities or after modification of alarm severities in profiles). This command should be applied once after having finisled modifications of severties. modifyAlarmSeverity: modifies the severity of an alarm in specific profile. createAlarmSeverityProfile: creates a new profile with default severities. The severities then have to be modified with command changeAlarmSeverity. deleteAlarmSeverityProfile: deletes a profile. Profile 1 is not allowed to be deleted. Notifications : none " ::= { sleFaultMgmtBaseControl 1 } sleFaultControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION " The status of a control request. " ::= { sleFaultMgmtBaseControl 2 } sleFaultControlTimer OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION " The maximum wait time for the manager for command ending. For long running commands. The manager reads this value from the DSLAM. " ::= { sleFaultMgmtBaseControl 3 } sleFaultControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION " The time stamp of the last command (end of command). " ::= { sleFaultMgmtBaseControl 4 } sleFaultControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION " The result of the last user command. " ::= { sleFaultMgmtBaseControl 5 } sleFaultControlDefaultSeverity OBJECT-TYPE SYNTAX INTEGER { critical(1), major(2), minor(3), warning(4), intermediate(5) } MAX-ACCESS read-write STATUS current DESCRIPTION " The severity of alarm. " ::= { sleFaultMgmtBaseControl 6 } sleFaultControlCriteriaSeverity OBJECT-TYPE SYNTAX INTEGER { critical(1), major(2), minor(3), warning(4), intermediate(5) } MAX-ACCESS read-write STATUS current DESCRIPTION " The severity of alarm. " ::= { sleFaultMgmtBaseControl 7 } sleFaultControlNotifiyActivity OBJECT-TYPE SYNTAX INTEGER { diabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION " The severity of alarm. " ::= { sleFaultMgmtBaseControl 8 } sleFaultMgmtBaseNotification OBJECT IDENTIFIER ::= { sleFaultMgmtBase 3 } sleAlarmDefaultSeverityChanged NOTIFICATION-TYPE OBJECTS { sleFaultDefaultSeverity, sleFaultControlRequest, sleFaultControlTimeStamp, sleFaultControlReqResult } STATUS current DESCRIPTION "Description." ::= { sleFaultMgmtBaseNotification 1 } sleAlarmDefaultCriteriaChanged NOTIFICATION-TYPE OBJECTS { sleFaultCriteriaSeverity, sleFaultControlRequest, sleFaultControlTimeStamp, sleFaultControlReqResult } STATUS current DESCRIPTION "Description." ::= { sleFaultMgmtBaseNotification 2 } sleNotificationActivityChanged NOTIFICATION-TYPE OBJECTS { sleFaultControlRequest, sleFaultControlTimeStamp, sleFaultControlReqResult, sleFaultNotifiyActivity } STATUS current DESCRIPTION "Description." ::= { sleFaultMgmtBaseNotification 3 } sleAlarmSeverity OBJECT IDENTIFIER ::= { sleFaultMgmt 2 } sleAlarmSeverityTable OBJECT-TYPE SYNTAX SEQUENCE OF SleAlarmSeverityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The alarm severity table. The alarm severity table associates profile index and AlarmID pairs with severities to be used for alarm traps. (Note that this table does not apply to cleared alarms). " ::= { sleAlarmSeverity 1 } sleAlarmSeverityEntry OBJECT-TYPE SYNTAX SleAlarmSeverityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Entry of the alarm severity table. " INDEX { sleAlarmSeverityIndex } ::= { sleAlarmSeverityTable 1 } SleAlarmSeverityEntry ::= SEQUENCE { sleAlarmSeverityIndex SpecificNum, sleAlarmSeverityValue INTEGER } sleAlarmSeverityIndex OBJECT-TYPE SYNTAX SpecificNum MAX-ACCESS read-only STATUS current DESCRIPTION "The following alarms is devided by the specific character, ===============. The division basis is that alarms is bounded or released. 001: portDown: To detect whether physical or logical interface's link status is up or down. 002: portUp: =============== 003: portRemoved: To detect whether physical interface is installed or not. 004: portInstalled: =============== 005: powerFail: To detect whether power module's operation status is good or not. (Without doubt, more than 1 power module should be equipped.) 006: powerOK: =============== 007: powerRemoved: To detect whether power module is installed or not, through the PLD access. (Without doubt, more than 1 power module should be equipped.) 008: powerInstalled: =============== 009: fanFail: To detect whether FAN module's operation status is good or not. 010: fanOK: =============== 011: fanRemoved: To detect whether FAN module is installed or not, through the PLD access. 012: fanInstalled: =============== 013: moduleRemoved: To detect whether physical interface module is installed or not, through the S/W I2C 014: moduleInstalled: =============== 015: systemRestart: Network system is restarted by operator. This is not H/W start but S/W start. =============== 016: systemStart: Network system is restarted by operator or system status. This is not S/W start but H/W start. (This alarm isn¡¯t used current) =============== 017: broadcastOver: To detect the receipt of broadcast packet. (This alarm isn¡¯t used current) 018: broadcastUnder: =============== 019: cpuOverLoad: To detect whether the configured CPU load threshold is less than current CPU load usage or not. 020: cpuUnderLoad: =============== 021: memoryOverUsed: To detect whether the configured memory threshold is less than current memory usage or not. 022: memoryUnderUsed: =============== 023: portOverThreshold: To detect whether the configured physical or logical interface threshold is less than delta value of current interface's InOctects or not. 024: portUnderThreshold: =============== 025: temperatureHigh: To detect whether the configured system's temperature threshold is less than current temperature or not. 026: temperatureLow: =============== 027: mfgdBlocked: To detect whether the specific MAC by MAC flood guard is blocked or not. 028: mfgdReleased: =============== 029: ipConflict: To detect whether the same IP address on different network node is configured or not. 030: ipUnconflict: =============== 031: dhcpLeaseShortage: To detect whether IP address that can be assigned to subscriber by DHCP server is sufficient or not. 032: dhcpLeaseSufficient: =============== 033: dhcpOccuredIllegalEntry: To detect whether a subsceiber is using a static IP address or not. 034: dhcpRemovedIllegalEntry: =============== 035: rmonAlarmRising: To detect whether rising threshold of a specific MO in RMON alarm sampling is less than current calculated value by alarm sample type or not. But alarm generation would be issued by means of event type in RMON event. 036: rmonAlarmNoRising: =============== 037: rmonAlarmFalling: To detect whether falling threshold of a specific MO in RMON alarm sampling is less than current calculated value by alarm sample type or not. But alarm generation would be issued by means of event type in RMON event. 038: rmonAlarmNoFalling: =============== 039: bpduGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not. In case of insertion edge node with 0 or lower priority than priority of current root bridge node, it will be disarrangement during a short time because of recognition a new inserted node as root bridge. So these edge ports is guarded, and then edge ports is blocked about all superior BPDU. So STP reconfiguration doesn't use this edge ports. =============== 040: rootGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not. In case of insertion edge node with 0 or lower priority than priority of current root bridge node, it will be disarrangement during a short time because of recognition a new inserted node as root bridge. So, Root guard prevents a new inserted node from being root bridge as well as receiving a superior BPDU from root bridge. but this node participates in STP topology reconfiguration. If root bridge does not send a superior BPDU, then this node acts usually though STP state change. =============== 041: portSecurity: To detect whether interface is configured for security or not. This can be used to prevent MAC from flooding as well as spoofing. That is, As a result, this will obstruct an attack as like DoS attack. =============== 042: userLogin: 043: userLogout: =============== 051: igmpGroupJoined: To detect whether a subscriber is joined a multicast group or not. 052: igmpGroupLeaved: =============== 053: dhcpIpaddressBound: To detect wether a dynamic IP address is assigned to a subscriber or not. 054: dhcpIpaddressFree: =============== 055: doorOpened: To detect whether outer door is opeded or not, as external alarm. 056: doorClosed: =============== 057: powerModeChangedPowerToBattery: To detect whether a system is using AC power or battery. A system is using AC power usually. If there is any power problems as like a power failure, a system is using battery instead of AC power. 058: powerModeChangedBatteryToPower: =============== 059: batterylowcapacity: To detect whether current battery capacity is less capacity threshold according to battery usage or not. The capacity of AC power is 16 voltage and battery is 20. Capacity threshold is configured by H/W specification. So operator can't change it. 060: batterynormalcapacity: =============== 061: batteryhighTemperature: To detect whether current temperature of battery is greater than temperature threshold or not. 062: batterynormalTemperature: =============== 063: authenticationFail: To detect whether the connected user is authentic or non-authentic. 064: authenticationNofail: =============== 065: psuAcHighTemperature: To detect whether current temperature of Power Supply Unit is greater than temperature threshold or not. 066: psuAcNormalTemperature: =============== 067: batteryRemoved: To detect whether battery is equipped at network system or not. Battery is used as redundancy power service. So operator can decide the installation of battery. 068: batteryEquipped: =============== 069: batteryLowVoltage: To detect whether battery voltage is less than 12.5 volt or not. 12.5 volt value is configured by H/W specification. So operator can't change it. 070: batteryNormalVoltage: =============== 071: adminAccessLogin: To detect whether a operator connects at this network system or not. 072: adminAccessLogout: =============== 073: cfgdBlocked: To detect whether it is blocked flood to CPU or not. 074: cfgdReleased: =============== 075: sfgdBlocked: To detect whether it is blocked flood to system or not. 076: sfgdReleased: =============== 077: swWatchdogAbnormalState: To detect whether a specific process acts normally or not. 078: swWatchdogNormalState: =============== 079: swWatchdogDetectError: To detect whether a specific process is detected a error related to itself or cleared. 080: swWatchdogClearError: =============== 081: ppsControlBlocked: To detect whether it is blocked by pps-control or not. 082: ppsControlReleased: =============== 083: gotDMITempHighOverAlarm: To detect whether internal temperature exceeds high alarm level or not. 084: gotDMITempHighFallAlarm: =============== 085: gotDMITempLowOverAlarm: To detect whether internal temperature is below low alarm level or not. 086: gotDMITempLowFallAlarm: =============== 087: gotDMITempHighOverWarning: To detect whether internal temperature exceeds high warning level or not. 088: gotDMITempHighFallWarning: =============== 089: gotDMITempLowOverWarning: To detect whether internal temperature is below low warning level or not. 090: gotDMITempLowFallWarning: =============== 091: gotDMIVolHighOverAlarm: To detect whether internal supply voltage exceeds high alarm level or not. 092: gotDMIVolHighFallAlarm: =============== 093: gotDMIVolLowOverAlarm: To detect whether internal supply voltage is below low alarm level or not. 094: gotDMIVolLowFallAlarm: =============== 095: gotDMIVolHighOverWarning: To detect whether internal supply voltage exceeds high warning level or not. 096: gotDMIVolHighFallWarning: =============== 097: gotDMIVolLowOverWarning: To detect whether internal supply voltage is below low warning level or not. 098: gotDMIVolLowFallWarning: =============== 099: gotDMITxBiasHighOverAlarm: To detect whether TX Bias current exceeds high alarm level or not. 100: gotDMITxBiasHighFallAlarm: =============== 101: gotDMITxBiasLowOverAlarm: To detect whether TX Bias current is below low alarm level or not. 102: gotDMITxBiasLowFallAlarm: =============== 103: gotDMITxBiasHighOverWarning: To detect whether TX Bias current exceeds high warning level or not. 104: gotDMITxBiasHighFallWarning: =============== 105: gotDMITxBiasLowOverWarning: To detect whether TX Bias current is below low warning level or not. 106: gotDMITxBiasLowFallWarning: =============== 107: gotDMITxPowerHighOverAlarm: To detect whether TX output power exceeds high alarm level or not. 108: gotDMITxPowerHighFallAlarm: =============== 109: gotDMITxPowerLowOverAlarm: To detect whether TX output power is below low alarm level or not. 110: gotDMITxPowerLowFallAlarm: =============== 111: gotDMITxPowerHighOverWarning: To detect whether TX output power exceeds high warning level or not. 112: gotDMITxPowerHighFallWarning: =============== 113: gotDMITxPowerLowOverWarning: To detect whether TX output power is below low warning level or not. 114: gotDMITxPowerLowFallWarning: =============== 115: gotDMIRxPowerHighOverAlarm: To detect whether RX output power exceeds high alarm level or not. 116: gotDMIRxPowerHighFallAlarm: =============== 117: gotDMIRxPowerLowOverAlarm: To detect whether RX output power is below low alarm level or not. 118: gotDMIRxPowerLowFallAlarm: =============== 119: gotDMIRxPowerHighOverWarning: To detect whether RX output power exceeds high warning level or not. 120: gotDMIRxPowerHighFallWarning: =============== 121: gotDMIRxPowerLowOverWarning: To detect whether RX output power is below low warning level or not. 122: gotDMIRxPowerLowFallWarning: =============== 123: nosRemoteUpgradeRequest: 124: nosRemoteUpgradeSuccess: 125: nosRemoteUpgradeFailAbort: 126: nosRemoteUpgradeFailHeaderError: 127: nosRemoteUpgradeFailDownloadError: 128: nosRemoteUpgradeFailFlashError: 129: nosRemoteUpgradeStart: =============== 130: systemDyingGasp: =============== 133: cliHistory: To detect whether CLI history is detected or not. 134: cliHistoryNo: =============== 135: ntpConnectionFail: To detect whether NTP connection is failed or not. 136: ntpConnectionFailNo: =============== 137: nmsConnectionTypeChanged: To detect whether NMS connection type is changed. =============== 159: clockModuleRemoved: To detect whether clock module is removed or installed. 160: clockModuleInstalled: 161: clockModuleInitFail: To detect whether clock module initiolization is failed or not. 162: clockModuleInitOk: =============== 163: cliHistoryLog: To detect whether CLI history log is over or not. 164: cliHistoryLogNo: =============== 165: slotActionEvent: To detect whether slot action is changed. 166: slotStateChange: To detect whether slot state is changed. =============== 167: interfaceAdminDown: To detect whether physical or logical interface's admin link status is up or down. 168: interfaceAdminUp: =============== 169: slotPowerMonAbnormal: To detect whether slot power monitor abnormal or normal is detected. 170: slotPowerMonNormal: =============== 171: slotErrorLEDChanged: To detect whether error LED is changed. =============== 185: cpuPpsOverThreshold: To detect whether PPS is over threshold or not. 186: cpuPpsUnderThreshold: =============== 199: slotHealthStatusTimeout: To detect whether slot health status is time out or not. 200: slotHealthStatusTimeoutCleared: =============== 201: advaTemperature: To detect whether current chassis temperature is less than chassis temperature threshold or not. 202: advaTemperatureNo: =============== 203: advaPSUFailure: To detect whether ADVA system's power supply unit has a failure or not. 204: advaPSUFailureNo: =============== 205: advaFanFailure: To detect whether ADVA system's FAN has a failure or not. 206: advaFanFailureNo: =============== 207: advaInterfaceReceiveFailure: To detect whether ADVA system's receipt has a failure or not. 208: advaInterfaceReceiveFailureNo: =============== 209: advaInterfaceOpticalThreshold: To detect whether Adva system's optical receive power level is less than optical threshold or not. 210: advaInterfaceOpticalThresholdNo: =============== 211: advaInterfaceTransmitFault: To detect whether ADVA system's transmission has a failure or not. 212: advaInterfaceTransmitFaultNo: =============== 213: dvaInterfaceMisconfiguration: To detect whether ADVA system's interface is configured rightly or not. 214: advaInterfaceMisconfigurationNo: =============== 215: advaInterfaceSFPMismatch: To detect whether ADVA system's SFP interface is mismatched or not. 216: advaInterfaceSFPMismatchNo: =============== 217: advaVoltageLow: To detect whether ADVA system's current voltage is less than voltage threshold or not. 218: advaVoltageLowNo: =============== 219: advaVoltageHigh: To detect whether ADVA system's current voltage is greater than voltage threshold or not. 220: advaVoltageHighNo: =============== 301: erpDomainLotp: To detect whether LOTP(Loss of Test Packet) exists a domain of ERP or not. The Loss of Test Packet defect is defined when a node does not receive any test packet at any of its ports for a period of 3 times. 302: erpDomainLotpNo: =============== 303: erpDomainULotp: To detect whether undirectional LOTP(Loss of Test Packet) exists a domain of ERP or not. The Loss of Test Packet defect is defined when a RM node of one domain does not receive any test packet at one port for a period of 3 times. 304: erpDomainULotpNo: =============== 305: erpDomainMultipleRM: To detect whether Multiple RM node is supported or not. The defect is raised when a RM node receives its own test packets with an Ack destination address field with a non-zero value. 306: erpDomainMultipleRMNo: =============== 307: erpDomainRMNodeReacheablity: To detect whether RM reachability is raised or not. The detection of multiple failures indicates that the ring is segmented and that the RM Node is unreacheable. This is only possible at normal ring nodes isolated from the RM node. 308: erpDomainRMNodeReacheablityNo: =============== 391: startupConfigLoadEnded: To detect whether startup configuration load is ended. =============== 401: eponOnuDeregister: To detect whether ONU is registered into OLT or not. That is, ONU that its operation is service on should be sent registration information to OLT. 402: eponOnuRegister: =============== 403: eponOnuRegistrationError: To detect whether ONU is failed registeration process into OLT. 404: eponOnuNoRegistrationError: =============== 405: eponBadEncryptionKey: To detect wwhether the encryption key is valid or not. A message between ONU and OLT is encrypted using random encryption key. There is that the encryption key is invalid as transmission failure from time to time. 406: eponNoBadEncryptionKey: =============== 407: eponLlidMistmatch: To detect whether Llid of message between ONU and OLT is valid or not. On registering, ONU informs unique ID to OLT. And then, all communication between ONU and OLT must use the unique ID. The unique ID is called Llid. 408: eponNoLlidMismatch: =============== 409: eponTooManyRegister: To detect whether the registered ONU per 1 OLT is greater than 32 or not. That is, ONU can be registered from 1 to the maximum 32 at 1 OLT. 410: eponNoTooManyRegister: =============== 411: eponDyingGASP: To detect whether a ONU is down from dying gasp or not. A ONU could be changed to down state as a number of reasons. By the way, ONU that is changed to down as dying gasp would be sent dying gasp signal to OLT and then ONU's link would be changed to down. 412: eponNoDyingGASP: =============== 413: eponOnuErrFramePeriod: 414: eponOnuNoErrFramePeriod: =============== 415: eponOnuErrFrame: 416: eponOnuNoErrFrame: =============== 417: eponOnuErrFrameSecondSummary: 418: eponOnuNoErrFrameSecondSummary: =============== 419: eponOnuLastOnuDeregister: To detect whether a deregistered ONU is last ONU or not. If a deregistered ONU is last ONU, the OLT would be changed to serviceable status. 420: eponOnuNoLastOnuDeregister: =============== 421: eponOltCableDown: 422: eponOltRecoverCableDown: =============== 501: autoCLIStart: To detect whether the scheduled auto CLI is started or not. 502: autoCLINoStart: =============== 503: autoCLIComplete: To detect whether the scheduled auto CLI is completed or not. 504: autoCLINoComplete: =============== 505: autoCLIRemoveOutputFile: To detect whether the result file of the scheduled auto CLI is removed or not. The reason that the result file is removed is that the configured file size for the result is less than the stored result file size. If so, the oldest file would be removed before everything. 506: autoCLINoRemoveOutputFile: =============== 507: autoResetSystem: To detect whether the system is restarted or not. The conditions that system is restarted is that ping loss threshold is less than current ping loss count during the configured interval and that current free memory size is less than configured free memory size. 508: autoResetNoSystem: =============== 509: autoResetPingReplyLoss: To detect whether ping reply from the designated network node is received or not. Operator designates any gateway system that can communicate to detect current network environment. System sends ICMP packet to the designated gateway system periodically. If the system doesn't receive ping reply packet within any interval, operator recognizes that the system can't communicate any more because of some problems of the system. 510: autoResetNoPingReplyLoss: =============== 511: autoResetMemoryLeakDetect: To detect whether current free memory size is less than the configured free memory size or not. Periodically, free memory size is checked to confirm system availability. 512: autoResetNoMemoryLeakDetect: =============== 601: arulePacketDropDetect: To detect whether it is dropped some packet by arule or not. 602: arulePacketDropRelease: =============== 620: bME1CardNoDetect: 621: clearBME1CardNoDetect: =============== 622: bME1CardAFEerror: 623: clearBME1CardAFEerror: =============== 624: bME1CardIFEerror: 625: clearBME1CardIFEerror: =============== 626: bME1CardFWerror: 627: clearBME1CardFWerror: =============== 628: bME1CardPROVerror: 629: clearBME1CardPROVerror: =============== 630: bME1CrashDetect: 631: clearBME1CrashDetect: =============== 632: bME2CardNoDetect: 633: clearBME2CardNoDetect: =============== 634: bME2CardAFEerror: 635: clearBME2CardAFEerror: =============== 636: bME2CardIFEerror: 637: clearBME2CardIFEerror: =============== 638: bME2CardFWerror: 639: clearBME2CardFWerror: =============== 640: bME2CardPROVerror: 641: clearBME2CardPROVerror: =============== 642: bME2CrashDetect: 643: clearBME2CrashDetect: =============== 644: bME3CardNoDetect: 645: clearBME3CardNoDetect: =============== 646: bME3CardAFEerror: 647: clearBME3CardAFEerror: =============== 648: bME3CardIFEerror: 649: clearBME3CardIFEerror: =============== 650: bME3CardFWerror: 651: clearBME3CardFWerror: =============== 652: bME3CardPROVerror: 653: clearBME3CardPROVerror: =============== 654: bME3CrashDetect: 655: clearBME3CrashDetect: =============== 656: powerFromBattery: 657: clearPowerFromBattery: =============== 658: invalidBatteryStatus: 659: clearInvalidBatteryStatus: =============== 660: batteryChargeLow: 661: clearBatteryChargeLow: =============== 662: batteryNotPresent: 663: clearBatteryNotPresent: =============== 664: voltageLow: 665: clearVoltageLow: =============== 666: tempOverThreshold: 667: clearTempOverThreshold: =============== 668: tempUnderThreshold: 669: clearTempUnderThreshold: =============== 670: cpuOverThreshold: 671: clearCpuOverThreshold: =============== 672: trafficOverload: 673: clearTrafficOverload: =============== 674: gEPONModuleNotDetect: 675: clearGEPONModuleNotDetect: =============== 676: gEPONPortOperationDown: 677: clearGEPONPortOperationDown: =============== 678: gEPONNoIncomingTraffic: 679: clearGEPONNoIncomingTraffic: =============== 680: processCrashDetect: 681: clearProcessCrashDetect: =============== 682: memoryLeakDetect: 683: clearMemoryLeakDetect: =============== 684: memoryCorrupDetect: 685: clearMemoryCorrupDetect: =============== 686: memoryLowDetect: 687: clearMemoryLowDetect: =============== 688: dataLineerror: 689: clearDataLineerror: =============== 690: addressLineerror: 691: clearAddressLineerror: =============== 692: chipsetNotDetcet: 693: clearChipsetNotDetcet: =============== 694: pciBuserror: 695: clearPciBuserror: =============== 696: securityAdminConnect: 697: clearSecurityAdminConnect: =============== 698: oNUPowerDown: 699: clearONUPowerDown: =============== 700: oNUNotRegister: 701: clearONUNotRegister: =============== 702: oNTOpticPre: 703: clearONTOpticPre: =============== 800: switchoverInitiated: =============== 801: switchoverDone: =============== 803: redConfigurationMisMatch: To detect whether redundancy configuration is mismatched. =============== 901: gponNoAuthCBU: To detect no auth CBU is detected. 902: gponDuplicateONU: To detect ONU is duplicated. 903: gponDyingGasp: To detect dying GASP is detected. 904: gponUpgradeComplete: To detect upgrade complete is detected. 905: gponDeregistered: To detect whether deregistered is detected or not. 906: gponRegistered: 907: gponRogueOnu: To detect rogue ONU is detected 908: gponOnuBatteryEvent: To detect whether ONU battery event is detected or not. 909: clearGponOnuBetteryEvent: 910: gponOnuPortOperStatus: To detectONU port operation statue is chagned. 911: gponTransceiverChanged: To detect transceiver is changed. 912: gponOltLosOn: To detect whether OLT LOS is on or off 913: gponOltLosOff: 914: gponOltLosiOn: To detect whether OLT LOSI is on or off 915: gponOltLosiOff: 916: gponDyingGaspOn: To detect whether dying GASP is on or off 917: gponDyingGaspOff: 918: gponOntOSUpgradeStatus: To detect ONT OS upgrade status is changed. 919: gponOntBLUpgradeStatus: To detect BL upgrade status is changed. 920: gponOltRxPowerLoss: To detect OLT RX power is loss. 921: gponOltRxPowerDetected: To detect OLT RX power status is changed. 922: gponOnuTemperatureHighOverThreshold: To detect whether ONU temperature exceeds high threshold or not. 923: gponOnuTemperatureHighFallThreshold: 924: gponOnuTemperatureLowOverThreshold: To detect whether ONU temperature belows low threshold or not. 925: gponOnuTemperatureLowFallThreshold: 926: gponOnuCpuOverThreshold: To detect whether ONU CPU exceeds threshold or not. 927: gponOnuCpuFallThreshold: 928: gponOnuMemoryOverThreshold: To detect whether memory exceeds threshold or not. 929: gponOnuMemoryFallThreshold: 930: gponOnuI2cFail: To detect ONU L2C fail is detected. 931: gponOnuRxOpticLowThreshAlarmOn: To detect whether ONU RX optic belows low threshold or not. 932: gponOnuRxOpticLowThreshAlarmOff: 933: gponOnuRxOpticHighThreshAlarmOn: To detect whether ONU RX optic exceeds high threshold or not. 934: gponOnuRxOpticHighThreshAlarmOff: 935: gponOltLOFIOn: To detect whether OLT LOFL is on or off 936: gponOltLOFIOff: 937: gponOltDOWOn: To detect whether OLT DOW is on or off 938: gponOltDOWOff: 939: gponOltSFOn: To detect whether OLT SF is on or off 940: gponOltSFOff: 941: gponOltSDOn: To detect whether OLT SD is on or off 942: gponOltSDOff: 943: gponOltLCDGIOn: To detect whether OLT LCDGL is on or off 944: gponOltLCDGIOff: 945: gponOltRDOn: To detect whether OLT RD is on or off 946: gponOltRDOff: 947: gponOltSUFOn: To detect whether OLT SUF is on or off 948: gponOltSUFOff: 949: gponOltLOAOn: To detect whether OLT LOA is on or off 950: gponOltLOAOff: 951: gponOltLOAMIOn: To detect whether OLT LOAML is on or off 952: gponOltLOAMIOff: 953: gponOltMEMOn: To detect whether OLT MEM is on or off 954: gponOltMEMOff: 955: gponOltPEEOn: To detect whether OLT PEE is on or off 956: gponOltPEEOff: 957: gponOltPSTOn: To detect whether OLT PST is on or off 958: gponOltPSTOff: 959: gponOltERROn: To detect whether OLT ERR is on or off 960: gponOltERROff: 961: gponOltREIOn: To detect whether OLT REI is on or off 962: gponOltREIOff: 963: gponAntiSpoofingDupPortOn: To detect whether anti spoofing port is duplicated or not. 964: gponAntiSpoofingDupPortOff: 965: gponRedundancySwitchOver: To detect redundancy switchover is changed. 966: gponDuplicatedRangingResponse: To detect ranging response is changed. 967: gponOnuPortOpticModuleRemove: To detect whether ONU port optic module is removed or installed. 968: gponOnuPortOpticModuleInstall: 969: gponOnuOMCCProblemDetected: To detect whether ONU OMCC problem is detected or not. 970: gponOnuOMCCProblemCleared: 971: gponOltFixedTcontAlarmOn: To detect whether OLT fixed Tcont alarm is on or off. 972: gponOltFixedTcontAlarmOff: 973: gponOltDynamicTcontAlarmOn: To detect whether OLT dynamic Tcont alarm is on or off. 974: gponOltDynamicTcontAlarmOff: 975: gponOltPortCountAlarmOn: To detect whether OLT port count alarm is on or off. 976: gponOltPortCountAlarmOff: 977: gponOltCableDownAlarmOn: To detect whether OLT cable down alarm is on or off. 978: gponOltCableDownAlarmOff: 979: gponOltDeactiveMonitorAlarmOn: To detect whether deactive monitor alarm is on or off. 980: gponOltDeactiveMonitorAlarmOff: 981: gponOltDfiOn: To detect whether OLT DFI is on or off. 982: gponOltDfiOff: 984: gponOltTransceiverPortChanged: To detect OLT transeiver port is changed. 985: gponOnuPortOperStatusDown: To detect whether ONU port operation status is down or up. 986: gponOnuPortOperStatusUp:: =============== 1101: emLogDefectCPUHighOver: To detect whether EM log detect CPU exceeds threshold or not. 1102: emLogDefectCPUHighUnder: 1103: emLogTemperHighOver: To detect whether EM log temperature exceeds high threshold or not. 1104: emLogTemperHighUnder: 1105: emLogTemperLowUnder: To detect whether EM log CPU belows low threshold or not. 1106: emLogTemperLowOver: 1107: emLogMemLowUnder: To detect whether EM log memory belows low threshold or not. 1108: emLogMemLowOver: 1109: emLogFanFail: To detect whether EM log fan status is failed or not. 1110: emLogFanFailCleared: 1111: emLogPhyCRCFail: To detect whether EM log physical CRC is failed or not. 1112: emLogPhyCRCFailCleared: 1113: emLogPhyDetectFail: To detect whether EM log physical status is failed or not. 1114: emLogPhyDetectFailCleared: 1115: emLogSFUMateInitFail: To detect whether EM log SFU mate initialization is failed or not. 1116: emLogSFUMateInitFailCleared: 1117: emLogDaemonHealthBad: To detect whether EM log daemon health is bad or not. 1118: emLogDaemonHealthBadCleared: 1119: emLogGPIURavenLinkDown: To detect whether EM log GPIU RAVEN link is down or not. 1120: emLogGPIURavenLinkDownCleared: =============== 1151: slotNosUpgradeStart: To detect whether slot NOS upgrade is started or ended. 1152: slotNosUpgradeEnd: =============== 1331: gponOnuAniVoltageLowThreshAlarmOn: To detect whether ONU ANI voltage belows low threshold or not. 1332: gponOnuAniVoltageLowThreshAlarmOff: 1333: gponOnuAniVoltageHighThreshAlarmOn: To detect whether ONU ANI voltage exceeds high threshold or not. 1334: gponOnuAniVoltageHighThreshAlarmOff: 1335: gponOnuAniTemperatureLowThreshAlarmOn: To detect whether ONU ANI temperature belows low threshold or not. 1336: gponOnuAniTemperatureLowThreshAlarmOff: 1337: gponOnuAniTemperatureHighThreshAlarmOn: To detect whether ONU ANI temperature exceeds high threshold or not. 1338: gponOnuAniTemperatureHighThreshAlarmOff: 1339: gponOnuAniTxBiasLowThreshAlarmOn: To detect whether ONU ANI TX bias belows low threshold or not. 1340: gponOnuAniTxBiasLowThreshAlarmOff: 1341: gponOnuAniTxBiasHighThreshAlarmOn: To detect whether ONU ANI TX bias exceeds high threshold or not. 1342: gponOnuAniTxBiasHighThreshAlarmOff: 1343: gponOnuAniTxpowerLowThreshAlarmOn: To detect whether ONU ANI TX power belows low threshold or not. 1344: gponOnuAniTxpowerLowThreshAlarmOff: 1345: gponOnuAniTxpowerHighThreshAlarmOn: To detect whether ONU ANI TX power exceeds high threshold or not. 1346: gponOnuAniTxpowerHighThreshAlarmOff:" ::= { sleAlarmSeverityEntry 1 } sleAlarmSeverityValue OBJECT-TYPE SYNTAX INTEGER { critical(1), major(2), minor(3), warning(4), intermediate(5) } MAX-ACCESS read-only STATUS current DESCRIPTION " The severity of alarm. " ::= { sleAlarmSeverityEntry 2 } sleAlarmSeverityControl OBJECT IDENTIFIER ::= { sleAlarmSeverity 2 } sleAlarmSeverityControlRequest OBJECT-TYPE SYNTAX INTEGER { createAlarmSeveriity(1), destroyAlarmSeveriity(2), setAlarmSeveriity(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " This attribute identifies the control commands. updateAlarmList: the NE updates entries of alarms in the sleAlarmListTable after having changed alarm severities of alarms (due to change profile pointers in managed entities or after modification of alarm severities in profiles). This command should be applied once after having finisled modifications of severties. modifyAlarmSeverity: modifies the severity of an alarm in specific profile. createAlarmSeverityProfile: creates a new profile with default severities. The severities then have to be modified with command changeAlarmSeverity. deleteAlarmSeverityProfile: deletes a profile. Profile 1 is not allowed to be deleted. Notifications : none " ::= { sleAlarmSeverityControl 1 } sleAlarmSeverityControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION " The status of a control request. " ::= { sleAlarmSeverityControl 2 } sleAlarmSeverityControlTimer OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION " The maximum wait time for the manager for command ending. For long running commands. The manager reads this value from the DSLAM. " ::= { sleAlarmSeverityControl 3 } sleAlarmSeverityControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION " The time stamp of the last command (end of command). " ::= { sleAlarmSeverityControl 4 } sleAlarmSeverityControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION " The result of the last user command. " ::= { sleAlarmSeverityControl 5 } sleAlarmSeverityControlIndex OBJECT-TYPE SYNTAX SpecificNum MAX-ACCESS read-write STATUS current DESCRIPTION " A number identifying this alarm severity profile. The following alarms is devided by the specific character, ===============. The division basis is that alarms is bounded or released. 001: portDown: To detect whether physical or logical interface's link status is up or down. 002: portUp: =============== 003: portRemoved: To detect whether physical interface is installed or not. 004: portInstalled: =============== 005: powerFail: To detect whether power module's operation status is good or not. (Without doubt, more than 1 power module should be equipped.) 006: powerOK: =============== 007: powerRemoved: To detect whether power module is installed or not, through the PLD access. (Without doubt, more than 1 power module should be equipped.) 008: powerInstalled: =============== 009: fanFail: To detect whether FAN module's operation status is good or not. 010: fanOK: =============== 011: fanRemoved: To detect whether FAN module is installed or not, through the PLD access. 012: fanInstalled: =============== 013: moduleRemoved: To detect whether physical interface module is installed or not, through the S/W I2C 014: moduleInstalled: =============== 015: systemRestart: Network system is restarted by operator. This is not H/W start but S/W start. =============== 016: systemStart: Network system is restarted by operator or system status. This is not S/W start but H/W start. (This alarm isn¡¯t used current) =============== 017: broadcastOver: To detect the receipt of broadcast packet. (This alarm isn¡¯t used current) 018: broadcastUnder: =============== 019: cpuOverLoad: To detect whether the configured CPU load threshold is less than current CPU load usage or not. 020: cpuUnderLoad: =============== 021: memoryOverUsed: To detect whether the configured memory threshold is less than current memory usage or not. 022: memoryUnderUsed: =============== 023: portOverThreshold: To detect whether the configured physical or logical interface threshold is less than delta value of current interface's InOctects or not. 024: portUnderThreshold: =============== 025: temperatureHigh: To detect whether the configured system's temperature threshold is less than current temperature or not. 026: temperatureLow: =============== 027: mfgdBlocked: To detect whether the specific MAC by MAC flood guard is blocked or not. 028: mfgdReleased: =============== 029: ipConflict: To detect whether the same IP address on different network node is configured or not. 030: ipUnconflict: =============== 031: dhcpLeaseShortage: To detect whether IP address that can be assigned to subscriber by DHCP server is sufficient or not. 032: dhcpLeaseSufficient: =============== 033: dhcpOccuredIllegalEntry: To detect whether a subsceiber is using a static IP address or not. 034: dhcpRemovedIllegalEntry: =============== 035: rmonAlarmRising: To detect whether rising threshold of a specific MO in RMON alarm sampling is less than current calculated value by alarm sample type or not. But alarm generation would be issued by means of event type in RMON event. 036: rmonAlarmNoRising: =============== 037: rmonAlarmFalling: To detect whether falling threshold of a specific MO in RMON alarm sampling is less than current calculated value by alarm sample type or not. But alarm generation would be issued by means of event type in RMON event. 038: rmonAlarmNoFalling: =============== 039: bpduGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not. In case of insertion edge node with 0 or lower priority than priority of current root bridge node, it will be disarrangement during a short time because of recognition a new inserted node as root bridge. So these edge ports is guarded, and then edge ports is blocked about all superior BPDU. So STP reconfiguration doesn't use this edge ports. =============== 040: rootGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not. In case of insertion edge node with 0 or lower priority than priority of current root bridge node, it will be disarrangement during a short time because of recognition a new inserted node as root bridge. So, Root guard prevents a new inserted node from being root bridge as well as receiving a superior BPDU from root bridge. but this node participates in STP topology reconfiguration. If root bridge does not send a superior BPDU, then this node acts usually though STP state change. =============== 041: portSecurity: To detect whether interface is configured for security or not. This can be used to prevent MAC from flooding as well as spoofing. That is, As a result, this will obstruct an attack as like DoS attack. =============== 042: userLogin: 043: userLogout: =============== 051: igmpGroupJoined: To detect whether a subscriber is joined a multicast group or not. 052: igmpGroupLeaved: =============== 053: dhcpIpaddressBound: To detect wether a dynamic IP address is assigned to a subscriber or not. 054: dhcpIpaddressFree: =============== 055: doorOpened: To detect whether outer door is opeded or not, as external alarm. 056: doorClosed: =============== 057: powerModeChangedPowerToBattery: To detect whether a system is using AC power or battery. A system is using AC power usually. If there is any power problems as like a power failure, a system is using battery instead of AC power. 058: powerModeChangedBatteryToPower: =============== 059: batterylowcapacity: To detect whether current battery capacity is less capacity threshold according to battery usage or not. The capacity of AC power is 16 voltage and battery is 20. Capacity threshold is configured by H/W specification. So operator can't change it. 060: batterynormalcapacity: =============== 061: batteryhighTemperature: To detect whether current temperature of battery is greater than temperature threshold or not. 062: batterynormalTemperature: =============== 063: authenticationFail: To detect whether the connected user is authentic or non-authentic. 064: authenticationNofail: =============== 065: psuAcHighTemperature: To detect whether current temperature of Power Supply Unit is greater than temperature threshold or not. 066: psuAcNormalTemperature: =============== 067: batteryRemoved: To detect whether battery is equipped at network system or not. Battery is used as redundancy power service. So operator can decide the installation of battery. 068: batteryEquipped: =============== 069: batteryLowVoltage: To detect whether battery voltage is less than 12.5 volt or not. 12.5 volt value is configured by H/W specification. So operator can't change it. 070: batteryNormalVoltage: =============== 071: adminAccessLogin: To detect whether a operator connects at this network system or not. 072: adminAccessLogout: =============== 073: cfgdBlocked: To detect whether it is blocked flood to CPU or not. 074: cfgdReleased: =============== 075: sfgdBlocked: To detect whether it is blocked flood to system or not. 076: sfgdReleased: =============== 077: swWatchdogAbnormalState: To detect whether a specific process acts normally or not. 078: swWatchdogNormalState: =============== 079: swWatchdogDetectError: To detect whether a specific process is detected a error related to itself or cleared. 080: swWatchdogClearError: =============== 081: ppsControlBlocked: To detect whether it is blocked by pps-control or not. 082: ppsControlReleased: =============== 083: gotDMITempHighOverAlarm: To detect whether internal temperature exceeds high alarm level or not. 084: gotDMITempHighFallAlarm: =============== 085: gotDMITempLowOverAlarm: To detect whether internal temperature is below low alarm level or not. 086: gotDMITempLowFallAlarm: =============== 087: gotDMITempHighOverWarning: To detect whether internal temperature exceeds high warning level or not. 088: gotDMITempHighFallWarning: =============== 089: gotDMITempLowOverWarning: To detect whether internal temperature is below low warning level or not. 090: gotDMITempLowFallWarning: =============== 091: gotDMIVolHighOverAlarm: To detect whether internal supply voltage exceeds high alarm level or not. 092: gotDMIVolHighFallAlarm: =============== 093: gotDMIVolLowOverAlarm: To detect whether internal supply voltage is below low alarm level or not. 094: gotDMIVolLowFallAlarm: =============== 095: gotDMIVolHighOverWarning: To detect whether internal supply voltage exceeds high warning level or not. 096: gotDMIVolHighFallWarning: =============== 097: gotDMIVolLowOverWarning: To detect whether internal supply voltage is below low warning level or not. 098: gotDMIVolLowFallWarning: =============== 099: gotDMITxBiasHighOverAlarm: To detect whether TX Bias current exceeds high alarm level or not. 100: gotDMITxBiasHighFallAlarm: =============== 101: gotDMITxBiasLowOverAlarm: To detect whether TX Bias current is below low alarm level or not. 102: gotDMITxBiasLowFallAlarm: =============== 103: gotDMITxBiasHighOverWarning: To detect whether TX Bias current exceeds high warning level or not. 104: gotDMITxBiasHighFallWarning: =============== 105: gotDMITxBiasLowOverWarning: To detect whether TX Bias current is below low warning level or not. 106: gotDMITxBiasLowFallWarning: =============== 107: gotDMITxPowerHighOverAlarm: To detect whether TX output power exceeds high alarm level or not. 108: gotDMITxPowerHighFallAlarm: =============== 109: gotDMITxPowerLowOverAlarm: To detect whether TX output power is below low alarm level or not. 110: gotDMITxPowerLowFallAlarm: =============== 111: gotDMITxPowerHighOverWarning: To detect whether TX output power exceeds high warning level or not. 112: gotDMITxPowerHighFallWarning: =============== 113: gotDMITxPowerLowOverWarning: To detect whether TX output power is below low warning level or not. 114: gotDMITxPowerLowFallWarning: =============== 115: gotDMIRxPowerHighOverAlarm: To detect whether RX output power exceeds high alarm level or not. 116: gotDMIRxPowerHighFallAlarm: =============== 117: gotDMIRxPowerLowOverAlarm: To detect whether RX output power is below low alarm level or not. 118: gotDMIRxPowerLowFallAlarm: =============== 119: gotDMIRxPowerHighOverWarning: To detect whether RX output power exceeds high warning level or not. 120: gotDMIRxPowerHighFallWarning: =============== 121: gotDMIRxPowerLowOverWarning: To detect whether RX output power is below low warning level or not. 122: gotDMIRxPowerLowFallWarning: =============== 123: nosRemoteUpgradeRequest: 124: nosRemoteUpgradeSuccess: 125: nosRemoteUpgradeFailAbort: 126: nosRemoteUpgradeFailHeaderError: 127: nosRemoteUpgradeFailDownloadError: 128: nosRemoteUpgradeFailFlashError: 129: nosRemoteUpgradeStart: =============== 130: systemDyingGasp: =============== 133: cliHistory: To detect whether CLI history is detected or not. 134: cliHistoryNo: =============== 135: ntpConnectionFail: To detect whether NTP connection is failed or not. 136: ntpConnectionFailNo: =============== 137: nmsConnectionTypeChanged: To detect whether NMS connection type is changed. =============== 159: clockModuleRemoved: To detect whether clock module is removed or installed. 160: clockModuleInstalled: 161: clockModuleInitFail: To detect whether clock module initiolization is failed or not. 162: clockModuleInitOk: =============== 163: cliHistoryLog: To detect whether CLI history log is over or not. 164: cliHistoryLogNo: =============== 165: slotActionEvent: To detect whether slot action is changed. 166: slotStateChange: To detect whether slot state is changed. =============== 167: interfaceAdminDown: To detect whether physical or logical interface's admin link status is up or down. 168: interfaceAdminUp: =============== 169: slotPowerMonAbnormal: To detect whether slot power monitor abnormal or normal is detected. 170: slotPowerMonNormal: =============== 171: slotErrorLEDChanged: To detect whether error LED is changed. =============== 185: cpuPpsOverThreshold: To detect whether PPS is over threshold or not. 186: cpuPpsUnderThreshold: =============== 199: slotHealthStatusTimeout: To detect whether slot health status is time out or not. 200: slotHealthStatusTimeoutCleared: =============== 201: advaTemperature: To detect whether current chassis temperature is less than chassis temperature threshold or not. 202: advaTemperatureNo: =============== 203: advaPSUFailure: To detect whether ADVA system's power supply unit has a failure or not. 204: advaPSUFailureNo: =============== 205: advaFanFailure: To detect whether ADVA system's FAN has a failure or not. 206: advaFanFailureNo: =============== 207: advaInterfaceReceiveFailure: To detect whether ADVA system's receipt has a failure or not. 208: advaInterfaceReceiveFailureNo: =============== 209: advaInterfaceOpticalThreshold: To detect whether Adva system's optical receive power level is less than optical threshold or not. 210: advaInterfaceOpticalThresholdNo: =============== 211: advaInterfaceTransmitFault: To detect whether ADVA system's transmission has a failure or not. 212: advaInterfaceTransmitFaultNo: =============== 213: dvaInterfaceMisconfiguration: To detect whether ADVA system's interface is configured rightly or not. 214: advaInterfaceMisconfigurationNo: =============== 215: advaInterfaceSFPMismatch: To detect whether ADVA system's SFP interface is mismatched or not. 216: advaInterfaceSFPMismatchNo: =============== 217: advaVoltageLow: To detect whether ADVA system's current voltage is less than voltage threshold or not. 218: advaVoltageLowNo: =============== 219: advaVoltageHigh: To detect whether ADVA system's current voltage is greater than voltage threshold or not. 220: advaVoltageHighNo: =============== 301: erpDomainLotp: To detect whether LOTP(Loss of Test Packet) exists a domain of ERP or not. The Loss of Test Packet defect is defined when a node does not receive any test packet at any of its ports for a period of 3 times. 302: erpDomainLotpNo: =============== 303: erpDomainULotp: To detect whether undirectional LOTP(Loss of Test Packet) exists a domain of ERP or not. The Loss of Test Packet defect is defined when a RM node of one domain does not receive any test packet at one port for a period of 3 times. 304: erpDomainULotpNo: =============== 305: erpDomainMultipleRM: To detect whether Multiple RM node is supported or not. The defect is raised when a RM node receives its own test packets with an Ack destination address field with a non-zero value. 306: erpDomainMultipleRMNo: =============== 307: erpDomainRMNodeReacheablity: To detect whether RM reachability is raised or not. The detection of multiple failures indicates that the ring is segmented and that the RM Node is unreacheable. This is only possible at normal ring nodes isolated from the RM node. 308: erpDomainRMNodeReacheablityNo: =============== 391: startupConfigLoadEnded: To detect whether startup configuration load is ended. =============== 401: eponOnuDeregister: To detect whether ONU is registered into OLT or not. That is, ONU that its operation is service on should be sent registration information to OLT. 402: eponOnuRegister: =============== 403: eponOnuRegistrationError: To detect whether ONU is failed registeration process into OLT. 404: eponOnuNoRegistrationError: =============== 405: eponBadEncryptionKey: To detect wwhether the encryption key is valid or not. A message between ONU and OLT is encrypted using random encryption key. There is that the encryption key is invalid as transmission failure from time to time. 406: eponNoBadEncryptionKey: =============== 407: eponLlidMistmatch: To detect whether Llid of message between ONU and OLT is valid or not. On registering, ONU informs unique ID to OLT. And then, all communication between ONU and OLT must use the unique ID. The unique ID is called Llid. 408: eponNoLlidMismatch: =============== 409: eponTooManyRegister: To detect whether the registered ONU per 1 OLT is greater than 32 or not. That is, ONU can be registered from 1 to the maximum 32 at 1 OLT. 410: eponNoTooManyRegister: =============== 411: eponDyingGASP: To detect whether a ONU is down from dying gasp or not. A ONU could be changed to down state as a number of reasons. By the way, ONU that is changed to down as dying gasp would be sent dying gasp signal to OLT and then ONU's link would be changed to down. 412: eponNoDyingGASP: =============== 413: eponOnuErrFramePeriod: 414: eponOnuNoErrFramePeriod: =============== 415: eponOnuErrFrame: 416: eponOnuNoErrFrame: =============== 417: eponOnuErrFrameSecondSummary: 418: eponOnuNoErrFrameSecondSummary: =============== 419: eponOnuLastOnuDeregister: To detect whether a deregistered ONU is last ONU or not. If a deregistered ONU is last ONU, the OLT would be changed to serviceable status. 420: eponOnuNoLastOnuDeregister: =============== 421: eponOltCableDown: 422: eponOltRecoverCableDown: =============== 501: autoCLIStart: To detect whether the scheduled auto CLI is started or not. 502: autoCLINoStart: =============== 503: autoCLIComplete: To detect whether the scheduled auto CLI is completed or not. 504: autoCLINoComplete: =============== 505: autoCLIRemoveOutputFile: To detect whether the result file of the scheduled auto CLI is removed or not. The reason that the result file is removed is that the configured file size for the result is less than the stored result file size. If so, the oldest file would be removed before everything. 506: autoCLINoRemoveOutputFile: =============== 507: autoResetSystem: To detect whether the system is restarted or not. The conditions that system is restarted is that ping loss threshold is less than current ping loss count during the configured interval and that current free memory size is less than configured free memory size. 508: autoResetNoSystem: =============== 509: autoResetPingReplyLoss: To detect whether ping reply from the designated network node is received or not. Operator designates any gateway system that can communicate to detect current network environment. System sends ICMP packet to the designated gateway system periodically. If the system doesn't receive ping reply packet within any interval, operator recognizes that the system can't communicate any more because of some problems of the system. 510: autoResetNoPingReplyLoss: =============== 511: autoResetMemoryLeakDetect: To detect whether current free memory size is less than the configured free memory size or not. Periodically, free memory size is checked to confirm system availability. 512: autoResetNoMemoryLeakDetect: =============== 601: arulePacketDropDetect: To detect whether it is dropped some packet by arule or not. 602: arulePacketDropRelease: =============== 620: bME1CardNoDetect: 621: clearBME1CardNoDetect: =============== 622: bME1CardAFEerror: 623: clearBME1CardAFEerror: =============== 624: bME1CardIFEerror: 625: clearBME1CardIFEerror: =============== 626: bME1CardFWerror: 627: clearBME1CardFWerror: =============== 628: bME1CardPROVerror: 629: clearBME1CardPROVerror: =============== 630: bME1CrashDetect: 631: clearBME1CrashDetect: =============== 632: bME2CardNoDetect: 633: clearBME2CardNoDetect: =============== 634: bME2CardAFEerror: 635: clearBME2CardAFEerror: =============== 636: bME2CardIFEerror: 637: clearBME2CardIFEerror: =============== 638: bME2CardFWerror: 639: clearBME2CardFWerror: =============== 640: bME2CardPROVerror: 641: clearBME2CardPROVerror: =============== 642: bME2CrashDetect: 643: clearBME2CrashDetect: =============== 644: bME3CardNoDetect: 645: clearBME3CardNoDetect: =============== 646: bME3CardAFEerror: 647: clearBME3CardAFEerror: =============== 648: bME3CardIFEerror: 649: clearBME3CardIFEerror: =============== 650: bME3CardFWerror: 651: clearBME3CardFWerror: =============== 652: bME3CardPROVerror: 653: clearBME3CardPROVerror: =============== 654: bME3CrashDetect: 655: clearBME3CrashDetect: =============== 656: powerFromBattery: 657: clearPowerFromBattery: =============== 658: invalidBatteryStatus: 659: clearInvalidBatteryStatus: =============== 660: batteryChargeLow: 661: clearBatteryChargeLow: =============== 662: batteryNotPresent: 663: clearBatteryNotPresent: =============== 664: voltageLow: 665: clearVoltageLow: =============== 666: tempOverThreshold: 667: clearTempOverThreshold: =============== 668: tempUnderThreshold: 669: clearTempUnderThreshold: =============== 670: cpuOverThreshold: 671: clearCpuOverThreshold: =============== 672: trafficOverload: 673: clearTrafficOverload: =============== 674: gEPONModuleNotDetect: 675: clearGEPONModuleNotDetect: =============== 676: gEPONPortOperationDown: 677: clearGEPONPortOperationDown: =============== 678: gEPONNoIncomingTraffic: 679: clearGEPONNoIncomingTraffic: =============== 680: processCrashDetect: 681: clearProcessCrashDetect: =============== 682: memoryLeakDetect: 683: clearMemoryLeakDetect: =============== 684: memoryCorrupDetect: 685: clearMemoryCorrupDetect: =============== 686: memoryLowDetect: 687: clearMemoryLowDetect: =============== 688: dataLineerror: 689: clearDataLineerror: =============== 690: addressLineerror: 691: clearAddressLineerror: =============== 692: chipsetNotDetcet: 693: clearChipsetNotDetcet: =============== 694: pciBuserror: 695: clearPciBuserror: =============== 696: securityAdminConnect: 697: clearSecurityAdminConnect: =============== 698: oNUPowerDown: 699: clearONUPowerDown: =============== 700: oNUNotRegister: 701: clearONUNotRegister: =============== 702: oNTOpticPre: 703: clearONTOpticPre: =============== 800: switchoverInitiated: =============== 801: switchoverDone: =============== 803: redConfigurationMisMatch: To detect whether redundancy configuration is mismatched. =============== 901: gponNoAuthCBU: To detect no auth CBU is detected. 902: gponDuplicateONU: To detect ONU is duplicated. 903: gponDyingGasp: To detect dying GASP is detected. 904: gponUpgradeComplete: To detect upgrade complete is detected. 905: gponDeregistered: To detect whether deregistered is detected or not. 906: gponRegistered: 907: gponRogueOnu: To detect rogue ONU is detected 908: gponOnuBatteryEvent: To detect whether ONU battery event is detected or not. 909: clearGponOnuBetteryEvent: 910: gponOnuPortOperStatus: To detectONU port operation statue is chagned. 911: gponTransceiverChanged: To detect transceiver is changed. 912: gponOltLosOn: To detect whether OLT LOS is on or off 913: gponOltLosOff: 914: gponOltLosiOn: To detect whether OLT LOSI is on or off 915: gponOltLosiOff: 916: gponDyingGaspOn: To detect whether dying GASP is on or off 917: gponDyingGaspOff: 918: gponOntOSUpgradeStatus: To detect ONT OS upgrade status is changed. 919: gponOntBLUpgradeStatus: To detect BL upgrade status is changed. 920: gponOltRxPowerLoss: To detect OLT RX power is loss. 921: gponOltRxPowerDetected: To detect OLT RX power status is changed. 922: gponOnuTemperatureHighOverThreshold: To detect whether ONU temperature exceeds high threshold or not. 923: gponOnuTemperatureHighFallThreshold: 924: gponOnuTemperatureLowOverThreshold: To detect whether ONU temperature belows low threshold or not. 925: gponOnuTemperatureLowFallThreshold: 926: gponOnuCpuOverThreshold: To detect whether ONU CPU exceeds threshold or not. 927: gponOnuCpuFallThreshold: 928: gponOnuMemoryOverThreshold: To detect whether memory exceeds threshold or not. 929: gponOnuMemoryFallThreshold: 930: gponOnuI2cFail: To detect ONU L2C fail is detected. 931: gponOnuRxOpticLowThreshAlarmOn: To detect whether ONU RX optic belows low threshold or not. 932: gponOnuRxOpticLowThreshAlarmOff: 933: gponOnuRxOpticHighThreshAlarmOn: To detect whether ONU RX optic exceeds high threshold or not. 934: gponOnuRxOpticHighThreshAlarmOff: 935: gponOltLOFIOn: To detect whether OLT LOFL is on or off 936: gponOltLOFIOff: 937: gponOltDOWOn: To detect whether OLT DOW is on or off 938: gponOltDOWOff: 939: gponOltSFOn: To detect whether OLT SF is on or off 940: gponOltSFOff: 941: gponOltSDOn: To detect whether OLT SD is on or off 942: gponOltSDOff: 943: gponOltLCDGIOn: To detect whether OLT LCDGL is on or off 944: gponOltLCDGIOff: 945: gponOltRDOn: To detect whether OLT RD is on or off 946: gponOltRDOff: 947: gponOltSUFOn: To detect whether OLT SUF is on or off 948: gponOltSUFOff: 949: gponOltLOAOn: To detect whether OLT LOA is on or off 950: gponOltLOAOff: 951: gponOltLOAMIOn: To detect whether OLT LOAML is on or off 952: gponOltLOAMIOff: 953: gponOltMEMOn: To detect whether OLT MEM is on or off 954: gponOltMEMOff: 955: gponOltPEEOn: To detect whether OLT PEE is on or off 956: gponOltPEEOff: 957: gponOltPSTOn: To detect whether OLT PST is on or off 958: gponOltPSTOff: 959: gponOltERROn: To detect whether OLT ERR is on or off 960: gponOltERROff: 961: gponOltREIOn: To detect whether OLT REI is on or off 962: gponOltREIOff: 963: gponAntiSpoofingDupPortOn: To detect whether anti spoofing port is duplicated or not. 964: gponAntiSpoofingDupPortOff: 965: gponRedundancySwitchOver: To detect redundancy switchover is changed. 966: gponDuplicatedRangingResponse: To detect ranging response is changed. 967: gponOnuPortOpticModuleRemove: To detect whether ONU port optic module is removed or installed. 968: gponOnuPortOpticModuleInstall: 969: gponOnuOMCCProblemDetected: To detect whether ONU OMCC problem is detected or not. 970: gponOnuOMCCProblemCleared: 971: gponOltFixedTcontAlarmOn: To detect whether OLT fixed Tcont alarm is on or off. 972: gponOltFixedTcontAlarmOff: 973: gponOltDynamicTcontAlarmOn: To detect whether OLT dynamic Tcont alarm is on or off. 974: gponOltDynamicTcontAlarmOff: 975: gponOltPortCountAlarmOn: To detect whether OLT port count alarm is on or off. 976: gponOltPortCountAlarmOff: 977: gponOltCableDownAlarmOn: To detect whether OLT cable down alarm is on or off. 978: gponOltCableDownAlarmOff: 979: gponOltDeactiveMonitorAlarmOn: To detect whether deactive monitor alarm is on or off. 980: gponOltDeactiveMonitorAlarmOff: 981: gponOltDfiOn: To detect whether OLT DFI is on or off. 982: gponOltDfiOff: 984: gponOltTransceiverPortChanged: To detect OLT transeiver port is changed. 985: gponOnuPortOperStatusDown: To detect whether ONU port operation status is down or up. 986: gponOnuPortOperStatusUp:: =============== 1101: emLogDefectCPUHighOver: To detect whether EM log detect CPU exceeds threshold or not. 1102: emLogDefectCPUHighUnder: 1103: emLogTemperHighOver: To detect whether EM log temperature exceeds high threshold or not. 1104: emLogTemperHighUnder: 1105: emLogTemperLowUnder: To detect whether EM log CPU belows low threshold or not. 1106: emLogTemperLowOver: 1107: emLogMemLowUnder: To detect whether EM log memory belows low threshold or not. 1108: emLogMemLowOver: 1109: emLogFanFail: To detect whether EM log fan status is failed or not. 1110: emLogFanFailCleared: 1111: emLogPhyCRCFail: To detect whether EM log physical CRC is failed or not. 1112: emLogPhyCRCFailCleared: 1113: emLogPhyDetectFail: To detect whether EM log physical status is failed or not. 1114: emLogPhyDetectFailCleared: 1115: emLogSFUMateInitFail: To detect whether EM log SFU mate initialization is failed or not. 1116: emLogSFUMateInitFailCleared: 1117: emLogDaemonHealthBad: To detect whether EM log daemon health is bad or not. 1118: emLogDaemonHealthBadCleared: 1119: emLogGPIURavenLinkDown: To detect whether EM log GPIU RAVEN link is down or not. 1120: emLogGPIURavenLinkDownCleared: =============== 1151: slotNosUpgradeStart: To detect whether slot NOS upgrade is started or ended. 1152: slotNosUpgradeEnd: =============== 1331: gponOnuAniVoltageLowThreshAlarmOn: To detect whether ONU ANI voltage belows low threshold or not. 1332: gponOnuAniVoltageLowThreshAlarmOff: 1333: gponOnuAniVoltageHighThreshAlarmOn: To detect whether ONU ANI voltage exceeds high threshold or not. 1334: gponOnuAniVoltageHighThreshAlarmOff: 1335: gponOnuAniTemperatureLowThreshAlarmOn: To detect whether ONU ANI temperature belows low threshold or not. 1336: gponOnuAniTemperatureLowThreshAlarmOff: 1337: gponOnuAniTemperatureHighThreshAlarmOn: To detect whether ONU ANI temperature exceeds high threshold or not. 1338: gponOnuAniTemperatureHighThreshAlarmOff: 1339: gponOnuAniTxBiasLowThreshAlarmOn: To detect whether ONU ANI TX bias belows low threshold or not. 1340: gponOnuAniTxBiasLowThreshAlarmOff: 1341: gponOnuAniTxBiasHighThreshAlarmOn: To detect whether ONU ANI TX bias exceeds high threshold or not. 1342: gponOnuAniTxBiasHighThreshAlarmOff: 1343: gponOnuAniTxpowerLowThreshAlarmOn: To detect whether ONU ANI TX power belows low threshold or not. 1344: gponOnuAniTxpowerLowThreshAlarmOff: 1345: gponOnuAniTxpowerHighThreshAlarmOn: To detect whether ONU ANI TX power exceeds high threshold or not. 1346: gponOnuAniTxpowerHighThreshAlarmOff:" ::= { sleAlarmSeverityControl 6 } sleAlarmSeverityControlValue OBJECT-TYPE SYNTAX INTEGER { critical(1), major(2), minor(3), warning(4), intermediate(5) } MAX-ACCESS read-write STATUS current DESCRIPTION " The severity of alarm. " ::= { sleAlarmSeverityControl 7 } sleAlarmSeverityNotification OBJECT IDENTIFIER ::= { sleAlarmSeverity 3 } sleAlarmSeveriityCreated NOTIFICATION-TYPE OBJECTS { sleAlarmSeverityValue, sleAlarmSeverityControlRequest, sleAlarmSeverityControlTimeStamp, sleAlarmSeverityControlReqResult } STATUS current DESCRIPTION "Description." ::= { sleAlarmSeverityNotification 1 } sleAlarmSeveriityDestroyed NOTIFICATION-TYPE OBJECTS { sleAlarmSeverityControlRequest, sleAlarmSeverityControlTimeStamp, sleAlarmSeverityControlReqResult, sleAlarmSeverityValue } STATUS current DESCRIPTION "Description." ::= { sleAlarmSeverityNotification 2 } sleAlarmSeverityChanged NOTIFICATION-TYPE OBJECTS { sleAlarmSeverityValue, sleAlarmSeverityControlRequest, sleAlarmSeverityControlTimeStamp, sleAlarmSeverityControlReqResult } STATUS current DESCRIPTION "Description." ::= { sleAlarmSeverityNotification 3 } sleAlarmReport OBJECT IDENTIFIER ::= { sleFaultMgmt 3 } sleAlarmReportTable OBJECT-TYPE SYNTAX SEQUENCE OF SleAlarmReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The alarm list table is used to store all reported alarms. " ::= { sleAlarmReport 1 } sleAlarmReportEntry OBJECT-TYPE SYNTAX SleAlarmReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Entry of the alarm lis table. " INDEX { sleAlarmSpecificCode, sleAlarmReportingSourceType, sleAlarmReportingSource } ::= { sleAlarmReportTable 1 } SleAlarmReportEntry ::= SEQUENCE { sleAlarmSpecificCode SpecificNum, sleAlarmReportingSourceType INTEGER, sleAlarmReportingSource OCTET STRING, sleAlarmSpecificSeverity INTEGER, sleAlarmSpecificProblem Unsigned32, sleAlarmSpecificProblemText OCTET STRING, sleAlarmTimeAndDate Integer32, sleAlarmSpecificSeqNum Counter32, sleAlarmReportPairType INTEGER } sleAlarmSpecificCode OBJECT-TYPE SYNTAX SpecificNum MAX-ACCESS read-only STATUS current DESCRIPTION " The OID of alarm. The following alarms is devided by the specific character, ===============. The division basis is that alarms is bounded or released. 001: portDown: To detect whether physical or logical interface's link status is up or down. 002: portUp: =============== 003: portRemoved: To detect whether physical interface is installed or not. 004: portInstalled: =============== 005: powerFail: To detect whether power module's operation status is good or not. (Without doubt, more than 1 power module should be equipped.) 006: powerOK: =============== 007: powerRemoved: To detect whether power module is installed or not, through the PLD access. (Without doubt, more than 1 power module should be equipped.) 008: powerInstalled: =============== 009: fanFail: To detect whether FAN module's operation status is good or not. 010: fanOK: =============== 011: fanRemoved: To detect whether FAN module is installed or not, through the PLD access. 012: fanInstalled: =============== 013: moduleRemoved: To detect whether physical interface module is installed or not, through the S/W I2C 014: moduleInstalled: =============== 015: systemRestart: Network system is restarted by operator. This is not H/W start but S/W start. =============== 016: systemStart: Network system is restarted by operator or system status. This is not S/W start but H/W start. (This alarm isn¡¯t used current) =============== 017: broadcastOver: To detect the receipt of broadcast packet. (This alarm isn¡¯t used current) 018: broadcastUnder: =============== 019: cpuOverLoad: To detect whether the configured CPU load threshold is less than current CPU load usage or not. 020: cpuUnderLoad: =============== 021: memoryOverUsed: To detect whether the configured memory threshold is less than current memory usage or not. 022: memoryUnderUsed: =============== 023: portOverThreshold: To detect whether the configured physical or logical interface threshold is less than delta value of current interface's InOctects or not. 024: portUnderThreshold: =============== 025: temperatureHigh: To detect whether the configured system's temperature threshold is less than current temperature or not. 026: temperatureLow: =============== 027: mfgdBlocked: To detect whether the specific MAC by MAC flood guard is blocked or not. 028: mfgdReleased: =============== 029: ipConflict: To detect whether the same IP address on different network node is configured or not. 030: ipUnconflict: =============== 031: dhcpLeaseShortage: To detect whether IP address that can be assigned to subscriber by DHCP server is sufficient or not. 032: dhcpLeaseSufficient: =============== 033: dhcpOccuredIllegalEntry: To detect whether a subsceiber is using a static IP address or not. 034: dhcpRemovedIllegalEntry: =============== 035: rmonAlarmRising: To detect whether rising threshold of a specific MO in RMON alarm sampling is less than current calculated value by alarm sample type or not. But alarm generation would be issued by means of event type in RMON event. 036: rmonAlarmNoRising: =============== 037: rmonAlarmFalling: To detect whether falling threshold of a specific MO in RMON alarm sampling is less than current calculated value by alarm sample type or not. But alarm generation would be issued by means of event type in RMON event. 038: rmonAlarmNoFalling: =============== 039: bpduGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not. In case of insertion edge node with 0 or lower priority than priority of current root bridge node, it will be disarrangement during a short time because of recognition a new inserted node as root bridge. So these edge ports is guarded, and then edge ports is blocked about all superior BPDU. So STP reconfiguration doesn't use this edge ports. =============== 040: rootGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not. In case of insertion edge node with 0 or lower priority than priority of current root bridge node, it will be disarrangement during a short time because of recognition a new inserted node as root bridge. So, Root guard prevents a new inserted node from being root bridge as well as receiving a superior BPDU from root bridge. but this node participates in STP topology reconfiguration. If root bridge does not send a superior BPDU, then this node acts usually though STP state change. =============== 041: portSecurity: To detect whether interface is configured for security or not. This can be used to prevent MAC from flooding as well as spoofing. That is, As a result, this will obstruct an attack as like DoS attack. =============== 042: userLogin: 043: userLogout: =============== 051: igmpGroupJoined: To detect whether a subscriber is joined a multicast group or not. 052: igmpGroupLeaved: =============== 053: dhcpIpaddressBound: To detect wether a dynamic IP address is assigned to a subscriber or not. 054: dhcpIpaddressFree: =============== 055: doorOpened: To detect whether outer door is opeded or not, as external alarm. 056: doorClosed: =============== 057: powerModeChangedPowerToBattery: To detect whether a system is using AC power or battery. A system is using AC power usually. If there is any power problems as like a power failure, a system is using battery instead of AC power. 058: powerModeChangedBatteryToPower: =============== 059: batterylowcapacity: To detect whether current battery capacity is less capacity threshold according to battery usage or not. The capacity of AC power is 16 voltage and battery is 20. Capacity threshold is configured by H/W specification. So operator can't change it. 060: batterynormalcapacity: =============== 061: batteryhighTemperature: To detect whether current temperature of battery is greater than temperature threshold or not. 062: batterynormalTemperature: =============== 063: authenticationFail: To detect whether the connected user is authentic or non-authentic. 064: authenticationNofail: =============== 065: psuAcHighTemperature: To detect whether current temperature of Power Supply Unit is greater than temperature threshold or not. 066: psuAcNormalTemperature: =============== 067: batteryRemoved: To detect whether battery is equipped at network system or not. Battery is used as redundancy power service. So operator can decide the installation of battery. 068: batteryEquipped: =============== 069: batteryLowVoltage: To detect whether battery voltage is less than 12.5 volt or not. 12.5 volt value is configured by H/W specification. So operator can't change it. 070: batteryNormalVoltage: =============== 071: adminAccessLogin: To detect whether a operator connects at this network system or not. 072: adminAccessLogout: =============== 073: cfgdBlocked: To detect whether it is blocked flood to CPU or not. 074: cfgdReleased: =============== 075: sfgdBlocked: To detect whether it is blocked flood to system or not. 076: sfgdReleased: =============== 077: swWatchdogAbnormalState: To detect whether a specific process acts normally or not. 078: swWatchdogNormalState: =============== 079: swWatchdogDetectError: To detect whether a specific process is detected a error related to itself or cleared. 080: swWatchdogClearError: =============== 081: ppsControlBlocked: To detect whether it is blocked by pps-control or not. 082: ppsControlReleased: =============== 083: gotDMITempHighOverAlarm: To detect whether internal temperature exceeds high alarm level or not. 084: gotDMITempHighFallAlarm: =============== 085: gotDMITempLowOverAlarm: To detect whether internal temperature is below low alarm level or not. 086: gotDMITempLowFallAlarm: =============== 087: gotDMITempHighOverWarning: To detect whether internal temperature exceeds high warning level or not. 088: gotDMITempHighFallWarning: =============== 089: gotDMITempLowOverWarning: To detect whether internal temperature is below low warning level or not. 090: gotDMITempLowFallWarning: =============== 091: gotDMIVolHighOverAlarm: To detect whether internal supply voltage exceeds high alarm level or not. 092: gotDMIVolHighFallAlarm: =============== 093: gotDMIVolLowOverAlarm: To detect whether internal supply voltage is below low alarm level or not. 094: gotDMIVolLowFallAlarm: =============== 095: gotDMIVolHighOverWarning: To detect whether internal supply voltage exceeds high warning level or not. 096: gotDMIVolHighFallWarning: =============== 097: gotDMIVolLowOverWarning: To detect whether internal supply voltage is below low warning level or not. 098: gotDMIVolLowFallWarning: =============== 099: gotDMITxBiasHighOverAlarm: To detect whether TX Bias current exceeds high alarm level or not. 100: gotDMITxBiasHighFallAlarm: =============== 101: gotDMITxBiasLowOverAlarm: To detect whether TX Bias current is below low alarm level or not. 102: gotDMITxBiasLowFallAlarm: =============== 103: gotDMITxBiasHighOverWarning: To detect whether TX Bias current exceeds high warning level or not. 104: gotDMITxBiasHighFallWarning: =============== 105: gotDMITxBiasLowOverWarning: To detect whether TX Bias current is below low warning level or not. 106: gotDMITxBiasLowFallWarning: =============== 107: gotDMITxPowerHighOverAlarm: To detect whether TX output power exceeds high alarm level or not. 108: gotDMITxPowerHighFallAlarm: =============== 109: gotDMITxPowerLowOverAlarm: To detect whether TX output power is below low alarm level or not. 110: gotDMITxPowerLowFallAlarm: =============== 111: gotDMITxPowerHighOverWarning: To detect whether TX output power exceeds high warning level or not. 112: gotDMITxPowerHighFallWarning: =============== 113: gotDMITxPowerLowOverWarning: To detect whether TX output power is below low warning level or not. 114: gotDMITxPowerLowFallWarning: =============== 115: gotDMIRxPowerHighOverAlarm: To detect whether RX output power exceeds high alarm level or not. 116: gotDMIRxPowerHighFallAlarm: =============== 117: gotDMIRxPowerLowOverAlarm: To detect whether RX output power is below low alarm level or not. 118: gotDMIRxPowerLowFallAlarm: =============== 119: gotDMIRxPowerHighOverWarning: To detect whether RX output power exceeds high warning level or not. 120: gotDMIRxPowerHighFallWarning: =============== 121: gotDMIRxPowerLowOverWarning: To detect whether RX output power is below low warning level or not. 122: gotDMIRxPowerLowFallWarning: =============== 123: nosRemoteUpgradeRequest: 124: nosRemoteUpgradeSuccess: 125: nosRemoteUpgradeFailAbort: 126: nosRemoteUpgradeFailHeaderError: 127: nosRemoteUpgradeFailDownloadError: 128: nosRemoteUpgradeFailFlashError: 129: nosRemoteUpgradeStart: =============== 130: systemDyingGasp: =============== 133: cliHistory: To detect whether CLI history is detected or not. 134: cliHistoryNo: =============== 135: ntpConnectionFail: To detect whether NTP connection is failed or not. 136: ntpConnectionFailNo: =============== 137: nmsConnectionTypeChanged: To detect whether NMS connection type is changed. =============== 159: clockModuleRemoved: To detect whether clock module is removed or installed. 160: clockModuleInstalled: 161: clockModuleInitFail: To detect whether clock module initiolization is failed or not. 162: clockModuleInitOk: =============== 163: cliHistoryLog: To detect whether CLI history log is over or not. 164: cliHistoryLogNo: =============== 165: slotActionEvent: To detect whether slot action is changed. 166: slotStateChange: To detect whether slot state is changed. =============== 167: interfaceAdminDown: To detect whether physical or logical interface's admin link status is up or down. 168: interfaceAdminUp: =============== 169: slotPowerMonAbnormal: To detect whether slot power monitor abnormal or normal is detected. 170: slotPowerMonNormal: =============== 171: slotErrorLEDChanged: To detect whether error LED is changed. =============== 185: cpuPpsOverThreshold: To detect whether PPS is over threshold or not. 186: cpuPpsUnderThreshold: =============== 199: slotHealthStatusTimeout: To detect whether slot health status is time out or not. 200: slotHealthStatusTimeoutCleared: =============== 201: advaTemperature: To detect whether current chassis temperature is less than chassis temperature threshold or not. 202: advaTemperatureNo: =============== 203: advaPSUFailure: To detect whether ADVA system's power supply unit has a failure or not. 204: advaPSUFailureNo: =============== 205: advaFanFailure: To detect whether ADVA system's FAN has a failure or not. 206: advaFanFailureNo: =============== 207: advaInterfaceReceiveFailure: To detect whether ADVA system's receipt has a failure or not. 208: advaInterfaceReceiveFailureNo: =============== 209: advaInterfaceOpticalThreshold: To detect whether Adva system's optical receive power level is less than optical threshold or not. 210: advaInterfaceOpticalThresholdNo: =============== 211: advaInterfaceTransmitFault: To detect whether ADVA system's transmission has a failure or not. 212: advaInterfaceTransmitFaultNo: =============== 213: dvaInterfaceMisconfiguration: To detect whether ADVA system's interface is configured rightly or not. 214: advaInterfaceMisconfigurationNo: =============== 215: advaInterfaceSFPMismatch: To detect whether ADVA system's SFP interface is mismatched or not. 216: advaInterfaceSFPMismatchNo: =============== 217: advaVoltageLow: To detect whether ADVA system's current voltage is less than voltage threshold or not. 218: advaVoltageLowNo: =============== 219: advaVoltageHigh: To detect whether ADVA system's current voltage is greater than voltage threshold or not. 220: advaVoltageHighNo: =============== 301: erpDomainLotp: To detect whether LOTP(Loss of Test Packet) exists a domain of ERP or not. The Loss of Test Packet defect is defined when a node does not receive any test packet at any of its ports for a period of 3 times. 302: erpDomainLotpNo: =============== 303: erpDomainULotp: To detect whether undirectional LOTP(Loss of Test Packet) exists a domain of ERP or not. The Loss of Test Packet defect is defined when a RM node of one domain does not receive any test packet at one port for a period of 3 times. 304: erpDomainULotpNo: =============== 305: erpDomainMultipleRM: To detect whether Multiple RM node is supported or not. The defect is raised when a RM node receives its own test packets with an Ack destination address field with a non-zero value. 306: erpDomainMultipleRMNo: =============== 307: erpDomainRMNodeReacheablity: To detect whether RM reachability is raised or not. The detection of multiple failures indicates that the ring is segmented and that the RM Node is unreacheable. This is only possible at normal ring nodes isolated from the RM node. 308: erpDomainRMNodeReacheablityNo: =============== 391: startupConfigLoadEnded: To detect whether startup configuration load is ended. =============== 401: eponOnuDeregister: To detect whether ONU is registered into OLT or not. That is, ONU that its operation is service on should be sent registration information to OLT. 402: eponOnuRegister: =============== 403: eponOnuRegistrationError: To detect whether ONU is failed registeration process into OLT. 404: eponOnuNoRegistrationError: =============== 405: eponBadEncryptionKey: To detect wwhether the encryption key is valid or not. A message between ONU and OLT is encrypted using random encryption key. There is that the encryption key is invalid as transmission failure from time to time. 406: eponNoBadEncryptionKey: =============== 407: eponLlidMistmatch: To detect whether Llid of message between ONU and OLT is valid or not. On registering, ONU informs unique ID to OLT. And then, all communication between ONU and OLT must use the unique ID. The unique ID is called Llid. 408: eponNoLlidMismatch: =============== 409: eponTooManyRegister: To detect whether the registered ONU per 1 OLT is greater than 32 or not. That is, ONU can be registered from 1 to the maximum 32 at 1 OLT. 410: eponNoTooManyRegister: =============== 411: eponDyingGASP: To detect whether a ONU is down from dying gasp or not. A ONU could be changed to down state as a number of reasons. By the way, ONU that is changed to down as dying gasp would be sent dying gasp signal to OLT and then ONU's link would be changed to down. 412: eponNoDyingGASP: =============== 413: eponOnuErrFramePeriod: 414: eponOnuNoErrFramePeriod: =============== 415: eponOnuErrFrame: 416: eponOnuNoErrFrame: =============== 417: eponOnuErrFrameSecondSummary: 418: eponOnuNoErrFrameSecondSummary: =============== 419: eponOnuLastOnuDeregister: To detect whether a deregistered ONU is last ONU or not. If a deregistered ONU is last ONU, the OLT would be changed to serviceable status. 420: eponOnuNoLastOnuDeregister: =============== 421: eponOltCableDown: 422: eponOltRecoverCableDown: =============== 501: autoCLIStart: To detect whether the scheduled auto CLI is started or not. 502: autoCLINoStart: =============== 503: autoCLIComplete: To detect whether the scheduled auto CLI is completed or not. 504: autoCLINoComplete: =============== 505: autoCLIRemoveOutputFile: To detect whether the result file of the scheduled auto CLI is removed or not. The reason that the result file is removed is that the configured file size for the result is less than the stored result file size. If so, the oldest file would be removed before everything. 506: autoCLINoRemoveOutputFile: =============== 507: autoResetSystem: To detect whether the system is restarted or not. The conditions that system is restarted is that ping loss threshold is less than current ping loss count during the configured interval and that current free memory size is less than configured free memory size. 508: autoResetNoSystem: =============== 509: autoResetPingReplyLoss: To detect whether ping reply from the designated network node is received or not. Operator designates any gateway system that can communicate to detect current network environment. System sends ICMP packet to the designated gateway system periodically. If the system doesn't receive ping reply packet within any interval, operator recognizes that the system can't communicate any more because of some problems of the system. 510: autoResetNoPingReplyLoss: =============== 511: autoResetMemoryLeakDetect: To detect whether current free memory size is less than the configured free memory size or not. Periodically, free memory size is checked to confirm system availability. 512: autoResetNoMemoryLeakDetect: =============== 601: arulePacketDropDetect: To detect whether it is dropped some packet by arule or not. 602: arulePacketDropRelease: =============== 620: bME1CardNoDetect: 621: clearBME1CardNoDetect: =============== 622: bME1CardAFEerror: 623: clearBME1CardAFEerror: =============== 624: bME1CardIFEerror: 625: clearBME1CardIFEerror: =============== 626: bME1CardFWerror: 627: clearBME1CardFWerror: =============== 628: bME1CardPROVerror: 629: clearBME1CardPROVerror: =============== 630: bME1CrashDetect: 631: clearBME1CrashDetect: =============== 632: bME2CardNoDetect: 633: clearBME2CardNoDetect: =============== 634: bME2CardAFEerror: 635: clearBME2CardAFEerror: =============== 636: bME2CardIFEerror: 637: clearBME2CardIFEerror: =============== 638: bME2CardFWerror: 639: clearBME2CardFWerror: =============== 640: bME2CardPROVerror: 641: clearBME2CardPROVerror: =============== 642: bME2CrashDetect: 643: clearBME2CrashDetect: =============== 644: bME3CardNoDetect: 645: clearBME3CardNoDetect: =============== 646: bME3CardAFEerror: 647: clearBME3CardAFEerror: =============== 648: bME3CardIFEerror: 649: clearBME3CardIFEerror: =============== 650: bME3CardFWerror: 651: clearBME3CardFWerror: =============== 652: bME3CardPROVerror: 653: clearBME3CardPROVerror: =============== 654: bME3CrashDetect: 655: clearBME3CrashDetect: =============== 656: powerFromBattery: 657: clearPowerFromBattery: =============== 658: invalidBatteryStatus: 659: clearInvalidBatteryStatus: =============== 660: batteryChargeLow: 661: clearBatteryChargeLow: =============== 662: batteryNotPresent: 663: clearBatteryNotPresent: =============== 664: voltageLow: 665: clearVoltageLow: =============== 666: tempOverThreshold: 667: clearTempOverThreshold: =============== 668: tempUnderThreshold: 669: clearTempUnderThreshold: =============== 670: cpuOverThreshold: 671: clearCpuOverThreshold: =============== 672: trafficOverload: 673: clearTrafficOverload: =============== 674: gEPONModuleNotDetect: 675: clearGEPONModuleNotDetect: =============== 676: gEPONPortOperationDown: 677: clearGEPONPortOperationDown: =============== 678: gEPONNoIncomingTraffic: 679: clearGEPONNoIncomingTraffic: =============== 680: processCrashDetect: 681: clearProcessCrashDetect: =============== 682: memoryLeakDetect: 683: clearMemoryLeakDetect: =============== 684: memoryCorrupDetect: 685: clearMemoryCorrupDetect: =============== 686: memoryLowDetect: 687: clearMemoryLowDetect: =============== 688: dataLineerror: 689: clearDataLineerror: =============== 690: addressLineerror: 691: clearAddressLineerror: =============== 692: chipsetNotDetcet: 693: clearChipsetNotDetcet: =============== 694: pciBuserror: 695: clearPciBuserror: =============== 696: securityAdminConnect: 697: clearSecurityAdminConnect: =============== 698: oNUPowerDown: 699: clearONUPowerDown: =============== 700: oNUNotRegister: 701: clearONUNotRegister: =============== 702: oNTOpticPre: 703: clearONTOpticPre: =============== 800: switchoverInitiated: =============== 801: switchoverDone: =============== 803: redConfigurationMisMatch: To detect whether redundancy configuration is mismatched. =============== 901: gponNoAuthCBU: To detect no auth CBU is detected. 902: gponDuplicateONU: To detect ONU is duplicated. 903: gponDyingGasp: To detect dying GASP is detected. 904: gponUpgradeComplete: To detect upgrade complete is detected. 905: gponDeregistered: To detect whether deregistered is detected or not. 906: gponRegistered: 907: gponRogueOnu: To detect rogue ONU is detected 908: gponOnuBatteryEvent: To detect whether ONU battery event is detected or not. 909: clearGponOnuBetteryEvent: 910: gponOnuPortOperStatus: To detectONU port operation statue is chagned. 911: gponTransceiverChanged: To detect transceiver is changed. 912: gponOltLosOn: To detect whether OLT LOS is on or off 913: gponOltLosOff: 914: gponOltLosiOn: To detect whether OLT LOSI is on or off 915: gponOltLosiOff: 916: gponDyingGaspOn: To detect whether dying GASP is on or off 917: gponDyingGaspOff: 918: gponOntOSUpgradeStatus: To detect ONT OS upgrade status is changed. 919: gponOntBLUpgradeStatus: To detect BL upgrade status is changed. 920: gponOltRxPowerLoss: To detect OLT RX power is loss. 921: gponOltRxPowerDetected: To detect OLT RX power status is changed. 922: gponOnuTemperatureHighOverThreshold: To detect whether ONU temperature exceeds high threshold or not. 923: gponOnuTemperatureHighFallThreshold: 924: gponOnuTemperatureLowOverThreshold: To detect whether ONU temperature belows low threshold or not. 925: gponOnuTemperatureLowFallThreshold: 926: gponOnuCpuOverThreshold: To detect whether ONU CPU exceeds threshold or not. 927: gponOnuCpuFallThreshold: 928: gponOnuMemoryOverThreshold: To detect whether memory exceeds threshold or not. 929: gponOnuMemoryFallThreshold: 930: gponOnuI2cFail: To detect ONU L2C fail is detected. 931: gponOnuRxOpticLowThreshAlarmOn: To detect whether ONU RX optic belows low threshold or not. 932: gponOnuRxOpticLowThreshAlarmOff: 933: gponOnuRxOpticHighThreshAlarmOn: To detect whether ONU RX optic exceeds high threshold or not. 934: gponOnuRxOpticHighThreshAlarmOff: 935: gponOltLOFIOn: To detect whether OLT LOFL is on or off 936: gponOltLOFIOff: 937: gponOltDOWOn: To detect whether OLT DOW is on or off 938: gponOltDOWOff: 939: gponOltSFOn: To detect whether OLT SF is on or off 940: gponOltSFOff: 941: gponOltSDOn: To detect whether OLT SD is on or off 942: gponOltSDOff: 943: gponOltLCDGIOn: To detect whether OLT LCDGL is on or off 944: gponOltLCDGIOff: 945: gponOltRDOn: To detect whether OLT RD is on or off 946: gponOltRDOff: 947: gponOltSUFOn: To detect whether OLT SUF is on or off 948: gponOltSUFOff: 949: gponOltLOAOn: To detect whether OLT LOA is on or off 950: gponOltLOAOff: 951: gponOltLOAMIOn: To detect whether OLT LOAML is on or off 952: gponOltLOAMIOff: 953: gponOltMEMOn: To detect whether OLT MEM is on or off 954: gponOltMEMOff: 955: gponOltPEEOn: To detect whether OLT PEE is on or off 956: gponOltPEEOff: 957: gponOltPSTOn: To detect whether OLT PST is on or off 958: gponOltPSTOff: 959: gponOltERROn: To detect whether OLT ERR is on or off 960: gponOltERROff: 961: gponOltREIOn: To detect whether OLT REI is on or off 962: gponOltREIOff: 963: gponAntiSpoofingDupPortOn: To detect whether anti spoofing port is duplicated or not. 964: gponAntiSpoofingDupPortOff: 965: gponRedundancySwitchOver: To detect redundancy switchover is changed. 966: gponDuplicatedRangingResponse: To detect ranging response is changed. 967: gponOnuPortOpticModuleRemove: To detect whether ONU port optic module is removed or installed. 968: gponOnuPortOpticModuleInstall: 969: gponOnuOMCCProblemDetected: To detect whether ONU OMCC problem is detected or not. 970: gponOnuOMCCProblemCleared: 971: gponOltFixedTcontAlarmOn: To detect whether OLT fixed Tcont alarm is on or off. 972: gponOltFixedTcontAlarmOff: 973: gponOltDynamicTcontAlarmOn: To detect whether OLT dynamic Tcont alarm is on or off. 974: gponOltDynamicTcontAlarmOff: 975: gponOltPortCountAlarmOn: To detect whether OLT port count alarm is on or off. 976: gponOltPortCountAlarmOff: 977: gponOltCableDownAlarmOn: To detect whether OLT cable down alarm is on or off. 978: gponOltCableDownAlarmOff: 979: gponOltDeactiveMonitorAlarmOn: To detect whether deactive monitor alarm is on or off. 980: gponOltDeactiveMonitorAlarmOff: 981: gponOltDfiOn: To detect whether OLT DFI is on or off. 982: gponOltDfiOff: 984: gponOltTransceiverPortChanged: To detect OLT transeiver port is changed. 985: gponOnuPortOperStatusDown: To detect whether ONU port operation status is down or up. 986: gponOnuPortOperStatusUp:: =============== 1101: emLogDefectCPUHighOver: To detect whether EM log detect CPU exceeds threshold or not. 1102: emLogDefectCPUHighUnder: 1103: emLogTemperHighOver: To detect whether EM log temperature exceeds high threshold or not. 1104: emLogTemperHighUnder: 1105: emLogTemperLowUnder: To detect whether EM log CPU belows low threshold or not. 1106: emLogTemperLowOver: 1107: emLogMemLowUnder: To detect whether EM log memory belows low threshold or not. 1108: emLogMemLowOver: 1109: emLogFanFail: To detect whether EM log fan status is failed or not. 1110: emLogFanFailCleared: 1111: emLogPhyCRCFail: To detect whether EM log physical CRC is failed or not. 1112: emLogPhyCRCFailCleared: 1113: emLogPhyDetectFail: To detect whether EM log physical status is failed or not. 1114: emLogPhyDetectFailCleared: 1115: emLogSFUMateInitFail: To detect whether EM log SFU mate initialization is failed or not. 1116: emLogSFUMateInitFailCleared: 1117: emLogDaemonHealthBad: To detect whether EM log daemon health is bad or not. 1118: emLogDaemonHealthBadCleared: 1119: emLogGPIURavenLinkDown: To detect whether EM log GPIU RAVEN link is down or not. 1120: emLogGPIURavenLinkDownCleared: =============== 1151: slotNosUpgradeStart: To detect whether slot NOS upgrade is started or ended. 1152: slotNosUpgradeEnd: =============== 1331: gponOnuAniVoltageLowThreshAlarmOn: To detect whether ONU ANI voltage belows low threshold or not. 1332: gponOnuAniVoltageLowThreshAlarmOff: 1333: gponOnuAniVoltageHighThreshAlarmOn: To detect whether ONU ANI voltage exceeds high threshold or not. 1334: gponOnuAniVoltageHighThreshAlarmOff: 1335: gponOnuAniTemperatureLowThreshAlarmOn: To detect whether ONU ANI temperature belows low threshold or not. 1336: gponOnuAniTemperatureLowThreshAlarmOff: 1337: gponOnuAniTemperatureHighThreshAlarmOn: To detect whether ONU ANI temperature exceeds high threshold or not. 1338: gponOnuAniTemperatureHighThreshAlarmOff: 1339: gponOnuAniTxBiasLowThreshAlarmOn: To detect whether ONU ANI TX bias belows low threshold or not. 1340: gponOnuAniTxBiasLowThreshAlarmOff: 1341: gponOnuAniTxBiasHighThreshAlarmOn: To detect whether ONU ANI TX bias exceeds high threshold or not. 1342: gponOnuAniTxBiasHighThreshAlarmOff: 1343: gponOnuAniTxpowerLowThreshAlarmOn: To detect whether ONU ANI TX power belows low threshold or not. 1344: gponOnuAniTxpowerLowThreshAlarmOff: 1345: gponOnuAniTxpowerHighThreshAlarmOn: To detect whether ONU ANI TX power exceeds high threshold or not. 1346: gponOnuAniTxpowerHighThreshAlarmOff:" ::= { sleAlarmReportEntry 1 } sleAlarmReportingSourceType OBJECT-TYPE SYNTAX INTEGER { entPhysicalEntity(1), ifIndex(2), vccTp(3), macAddress(4), ipv4(5), ipv6(6), threshold(7), advaSource(8), number(9), general(10), eponSource(11), gponSource(12), gponSourceTlv(13) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of Reporting source In case of source type 13 gponSourceTlv, It's shown as below. sleAlarmReportingSourceType.A.B.C.D.E.F A: sleAlarmSpecificCode B: sleAlarmReportingSourceType 13 C: sleAlarmReportingSource's length D: type 1-slot 2-port 3-vlan 4-MAC 5-ONU 6-UNI_type 7-UNI_index 255-etc E: legth F: value " ::= { sleAlarmReportEntry 2 } sleAlarmReportingSource OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION " The alarm severity of alarm. In case of source type 13 gponSourceTlv, It's shown as below. sleAlarmReportingSourceType.A.B.C.D.E.F A: sleAlarmSpecificCode B: sleAlarmReportingSourceType 13 C: sleAlarmReportingSource's length D: type 1-slot 2-port 3-vlan 4-MAC 5-ONU 6-UNI_type 7-UNI_index 255-etc E: legth F: value" ::= { sleAlarmReportEntry 3 } sleAlarmSpecificSeverity OBJECT-TYPE SYNTAX INTEGER { critical(1), major(2), minor(3), warning(4), intermediate(5), cleared(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm severity. The value cleared indicates the clearing of alarm." ::= { sleAlarmReportEntry 4 } sleAlarmSpecificProblem OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the spefic problems e.g. when a shePhysCardFailure is sent here the termperature alarm is specified" ::= { sleAlarmReportEntry 5 } sleAlarmSpecificProblemText OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Textual description of specific problem reported by alarming. To be discussed: Option is to define an alarm for every problem " ::= { sleAlarmReportEntry 6 } sleAlarmTimeAndDate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The date and time when the alarm appeared or cleared" ::= { sleAlarmReportEntry 7 } sleAlarmSpecificSeqNum OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Sequence number for the alarm synchronization. This value has a number to be used for the next alarm trap." ::= { sleAlarmReportEntry 8 } sleAlarmReportPairType OBJECT-TYPE SYNTAX INTEGER { pair(0), mono(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type is whether alarm trap is pair or mono." ::= { sleAlarmReportEntry 9 } sleAlarmReportNotification OBJECT IDENTIFIER ::= { sleAlarmReport 2 } sleAlarmReportNotified NOTIFICATION-TYPE OBJECTS { sleAlarmSpecificCode, sleAlarmReportingSourceType, sleAlarmReportingSource, sleAlarmTimeAndDate, sleAlarmSpecificSeverity, sleAlarmSpecificProblem, sleAlarmSpecificProblemText, sleAlarmSpecificSeqNum } STATUS current DESCRIPTION "Description." ::= { sleAlarmReportNotification 1 } sleAlarmReportControl OBJECT IDENTIFIER ::= { sleAlarmReport 3 } sleAlarmReportControlRequest OBJECT-TYPE SYNTAX INTEGER { clearAlarmReport(1), delAlarmReport(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAlarmReportControl 1 } sleAlarmReportControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleAlarmReportControl 2 } sleAlarmReportControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAlarmReportControl 3 } sleAlarmReportControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleAlarmReportControl 4 } sleAlarmReportControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleAlarmReportControl 5 } sleAlarmReportControlSpecificCode OBJECT-TYPE SYNTAX SpecificNum MAX-ACCESS read-write STATUS current DESCRIPTION "Alarm specific code" ::= { sleAlarmReportControl 6 } sleAlarmReportControlSourceType OBJECT-TYPE SYNTAX INTEGER { entPhysicalEntity(1), ifIndex(2), vccTp(3), macAddress(4), ipv4(5), ipv6(6), threshold(7), advaSource(8), number(9), general(10), eponSource(11), gponSource(12) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of Reporting source" ::= { sleAlarmReportControl 7 } sleAlarmReportControlSource OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "The index of the failed component which reports the alarm. It is the entPhysicalIndex in case of a card is reporting, or the ifIndex in case of an interface reporting" ::= { sleAlarmReportControl 8 } sleAlarmReportNotifications OBJECT IDENTIFIER ::= { sleAlarmReport 4 } sleAlarmReportCleared NOTIFICATION-TYPE OBJECTS { sleAlarmReportControlRequest, sleAlarmReportControlTimeStamp, sleAlarmReportControlReqResult } STATUS current DESCRIPTION "Description." ::= { sleAlarmReportNotifications 1 } sleAlarmReportDeleted NOTIFICATION-TYPE OBJECTS { sleAlarmReportControlRequest, sleAlarmReportControlTimeStamp, sleAlarmReportControlReqResult, sleAlarmReportControlSpecificCode, sleAlarmReportControlSourceType, sleAlarmReportControlSource } STATUS current DESCRIPTION "Description." ::= { sleAlarmReportNotifications 2 } sleAlarmHistory OBJECT IDENTIFIER ::= { sleFaultMgmt 4 } sleAlarmHistoryTable OBJECT-TYPE SYNTAX SEQUENCE OF SleAlarmHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The alarm severity table. The alarm severity table associates profile index and AlarmID pairs with severities to be used for alarm traps. (Note that this table does not apply to cleared alarms). " ::= { sleAlarmHistory 1 } sleAlarmHistoryEntry OBJECT-TYPE SYNTAX SleAlarmHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Entry of the alarm severity table. " INDEX { sleAlarmHistoryIndex } ::= { sleAlarmHistoryTable 1 } SleAlarmHistoryEntry ::= SEQUENCE { sleAlarmHistoryIndex INTEGER, sleAlarmHistorySpecific SpecificNum, sleAlarmHistorySeverity INTEGER, sleAlarmHistoryText OCTET STRING, sleAlarmHistoryTime Integer32, sleAlarmHistorySeqNum Counter32, sleAlarmHistoryPairType INTEGER } sleAlarmHistoryIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " The OID of alarm. " ::= { sleAlarmHistoryEntry 1 } sleAlarmHistorySpecific OBJECT-TYPE SYNTAX SpecificNum MAX-ACCESS read-only STATUS current DESCRIPTION " The OID of alarm. The following alarms is devided by the specific character, ===============. The division basis is that alarms is bounded or released. 001: portDown: To detect whether physical or logical interface's link status is up or down. 002: portUp: =============== 003: portRemoved: To detect whether physical interface is installed or not. 004: portInstalled: =============== 005: powerFail: To detect whether power module's operation status is good or not. (Without doubt, more than 1 power module should be equipped.) 006: powerOK: =============== 007: powerRemoved: To detect whether power module is installed or not, through the PLD access. (Without doubt, more than 1 power module should be equipped.) 008: powerInstalled: =============== 009: fanFail: To detect whether FAN module's operation status is good or not. 010: fanOK: =============== 011: fanRemoved: To detect whether FAN module is installed or not, through the PLD access. 012: fanInstalled: =============== 013: moduleRemoved: To detect whether physical interface module is installed or not, through the S/W I2C 014: moduleInstalled: =============== 015: systemRestart: Network system is restarted by operator. This is not H/W start but S/W start. =============== 016: systemStart: Network system is restarted by operator or system status. This is not S/W start but H/W start. (This alarm isn¡¯t used current) =============== 017: broadcastOver: To detect the receipt of broadcast packet. (This alarm isn¡¯t used current) 018: broadcastUnder: =============== 019: cpuOverLoad: To detect whether the configured CPU load threshold is less than current CPU load usage or not. 020: cpuUnderLoad: =============== 021: memoryOverUsed: To detect whether the configured memory threshold is less than current memory usage or not. 022: memoryUnderUsed: =============== 023: portOverThreshold: To detect whether the configured physical or logical interface threshold is less than delta value of current interface's InOctects or not. 024: portUnderThreshold: =============== 025: temperatureHigh: To detect whether the configured system's temperature threshold is less than current temperature or not. 026: temperatureLow: =============== 027: mfgdBlocked: To detect whether the specific MAC by MAC flood guard is blocked or not. 028: mfgdReleased: =============== 029: ipConflict: To detect whether the same IP address on different network node is configured or not. 030: ipUnconflict: =============== 031: dhcpLeaseShortage: To detect whether IP address that can be assigned to subscriber by DHCP server is sufficient or not. 032: dhcpLeaseSufficient: =============== 033: dhcpOccuredIllegalEntry: To detect whether a subsceiber is using a static IP address or not. 034: dhcpRemovedIllegalEntry: =============== 035: rmonAlarmRising: To detect whether rising threshold of a specific MO in RMON alarm sampling is less than current calculated value by alarm sample type or not. But alarm generation would be issued by means of event type in RMON event. 036: rmonAlarmNoRising: =============== 037: rmonAlarmFalling: To detect whether falling threshold of a specific MO in RMON alarm sampling is less than current calculated value by alarm sample type or not. But alarm generation would be issued by means of event type in RMON event. 038: rmonAlarmNoFalling: =============== 039: bpduGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not. In case of insertion edge node with 0 or lower priority than priority of current root bridge node, it will be disarrangement during a short time because of recognition a new inserted node as root bridge. So these edge ports is guarded, and then edge ports is blocked about all superior BPDU. So STP reconfiguration doesn't use this edge ports. =============== 040: rootGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not. In case of insertion edge node with 0 or lower priority than priority of current root bridge node, it will be disarrangement during a short time because of recognition a new inserted node as root bridge. So, Root guard prevents a new inserted node from being root bridge as well as receiving a superior BPDU from root bridge. but this node participates in STP topology reconfiguration. If root bridge does not send a superior BPDU, then this node acts usually though STP state change. =============== 041: portSecurity: To detect whether interface is configured for security or not. This can be used to prevent MAC from flooding as well as spoofing. That is, As a result, this will obstruct an attack as like DoS attack. =============== 042: userLogin: 043: userLogout: =============== 051: igmpGroupJoined: To detect whether a subscriber is joined a multicast group or not. 052: igmpGroupLeaved: =============== 053: dhcpIpaddressBound: To detect wether a dynamic IP address is assigned to a subscriber or not. 054: dhcpIpaddressFree: =============== 055: doorOpened: To detect whether outer door is opeded or not, as external alarm. 056: doorClosed: =============== 057: powerModeChangedPowerToBattery: To detect whether a system is using AC power or battery. A system is using AC power usually. If there is any power problems as like a power failure, a system is using battery instead of AC power. 058: powerModeChangedBatteryToPower: =============== 059: batterylowcapacity: To detect whether current battery capacity is less capacity threshold according to battery usage or not. The capacity of AC power is 16 voltage and battery is 20. Capacity threshold is configured by H/W specification. So operator can't change it. 060: batterynormalcapacity: =============== 061: batteryhighTemperature: To detect whether current temperature of battery is greater than temperature threshold or not. 062: batterynormalTemperature: =============== 063: authenticationFail: To detect whether the connected user is authentic or non-authentic. 064: authenticationNofail: =============== 065: psuAcHighTemperature: To detect whether current temperature of Power Supply Unit is greater than temperature threshold or not. 066: psuAcNormalTemperature: =============== 067: batteryRemoved: To detect whether battery is equipped at network system or not. Battery is used as redundancy power service. So operator can decide the installation of battery. 068: batteryEquipped: =============== 069: batteryLowVoltage: To detect whether battery voltage is less than 12.5 volt or not. 12.5 volt value is configured by H/W specification. So operator can't change it. 070: batteryNormalVoltage: =============== 071: adminAccessLogin: To detect whether a operator connects at this network system or not. 072: adminAccessLogout: =============== 073: cfgdBlocked: To detect whether it is blocked flood to CPU or not. 074: cfgdReleased: =============== 075: sfgdBlocked: To detect whether it is blocked flood to system or not. 076: sfgdReleased: =============== 077: swWatchdogAbnormalState: To detect whether a specific process acts normally or not. 078: swWatchdogNormalState: =============== 079: swWatchdogDetectError: To detect whether a specific process is detected a error related to itself or cleared. 080: swWatchdogClearError: =============== 081: ppsControlBlocked: To detect whether it is blocked by pps-control or not. 082: ppsControlReleased: =============== 083: gotDMITempHighOverAlarm: To detect whether internal temperature exceeds high alarm level or not. 084: gotDMITempHighFallAlarm: =============== 085: gotDMITempLowOverAlarm: To detect whether internal temperature is below low alarm level or not. 086: gotDMITempLowFallAlarm: =============== 087: gotDMITempHighOverWarning: To detect whether internal temperature exceeds high warning level or not. 088: gotDMITempHighFallWarning: =============== 089: gotDMITempLowOverWarning: To detect whether internal temperature is below low warning level or not. 090: gotDMITempLowFallWarning: =============== 091: gotDMIVolHighOverAlarm: To detect whether internal supply voltage exceeds high alarm level or not. 092: gotDMIVolHighFallAlarm: =============== 093: gotDMIVolLowOverAlarm: To detect whether internal supply voltage is below low alarm level or not. 094: gotDMIVolLowFallAlarm: =============== 095: gotDMIVolHighOverWarning: To detect whether internal supply voltage exceeds high warning level or not. 096: gotDMIVolHighFallWarning: =============== 097: gotDMIVolLowOverWarning: To detect whether internal supply voltage is below low warning level or not. 098: gotDMIVolLowFallWarning: =============== 099: gotDMITxBiasHighOverAlarm: To detect whether TX Bias current exceeds high alarm level or not. 100: gotDMITxBiasHighFallAlarm: =============== 101: gotDMITxBiasLowOverAlarm: To detect whether TX Bias current is below low alarm level or not. 102: gotDMITxBiasLowFallAlarm: =============== 103: gotDMITxBiasHighOverWarning: To detect whether TX Bias current exceeds high warning level or not. 104: gotDMITxBiasHighFallWarning: =============== 105: gotDMITxBiasLowOverWarning: To detect whether TX Bias current is below low warning level or not. 106: gotDMITxBiasLowFallWarning: =============== 107: gotDMITxPowerHighOverAlarm: To detect whether TX output power exceeds high alarm level or not. 108: gotDMITxPowerHighFallAlarm: =============== 109: gotDMITxPowerLowOverAlarm: To detect whether TX output power is below low alarm level or not. 110: gotDMITxPowerLowFallAlarm: =============== 111: gotDMITxPowerHighOverWarning: To detect whether TX output power exceeds high warning level or not. 112: gotDMITxPowerHighFallWarning: =============== 113: gotDMITxPowerLowOverWarning: To detect whether TX output power is below low warning level or not. 114: gotDMITxPowerLowFallWarning: =============== 115: gotDMIRxPowerHighOverAlarm: To detect whether RX output power exceeds high alarm level or not. 116: gotDMIRxPowerHighFallAlarm: =============== 117: gotDMIRxPowerLowOverAlarm: To detect whether RX output power is below low alarm level or not. 118: gotDMIRxPowerLowFallAlarm: =============== 119: gotDMIRxPowerHighOverWarning: To detect whether RX output power exceeds high warning level or not. 120: gotDMIRxPowerHighFallWarning: =============== 121: gotDMIRxPowerLowOverWarning: To detect whether RX output power is below low warning level or not. 122: gotDMIRxPowerLowFallWarning: =============== 123: nosRemoteUpgradeRequest: 124: nosRemoteUpgradeSuccess: 125: nosRemoteUpgradeFailAbort: 126: nosRemoteUpgradeFailHeaderError: 127: nosRemoteUpgradeFailDownloadError: 128: nosRemoteUpgradeFailFlashError: 129: nosRemoteUpgradeStart: =============== 130: systemDyingGasp: =============== 133: cliHistory: To detect whether CLI history is detected or not. 134: cliHistoryNo: =============== 135: ntpConnectionFail: To detect whether NTP connection is failed or not. 136: ntpConnectionFailNo: =============== 137: nmsConnectionTypeChanged: To detect whether NMS connection type is changed. =============== 159: clockModuleRemoved: To detect whether clock module is removed or installed. 160: clockModuleInstalled: 161: clockModuleInitFail: To detect whether clock module initiolization is failed or not. 162: clockModuleInitOk: =============== 163: cliHistoryLog: To detect whether CLI history log is over or not. 164: cliHistoryLogNo: =============== 165: slotActionEvent: To detect whether slot action is changed. 166: slotStateChange: To detect whether slot state is changed. =============== 167: interfaceAdminDown: To detect whether physical or logical interface's admin link status is up or down. 168: interfaceAdminUp: =============== 169: slotPowerMonAbnormal: To detect whether slot power monitor abnormal or normal is detected. 170: slotPowerMonNormal: =============== 171: slotErrorLEDChanged: To detect whether error LED is changed. =============== 185: cpuPpsOverThreshold: To detect whether PPS is over threshold or not. 186: cpuPpsUnderThreshold: =============== 199: slotHealthStatusTimeout: To detect whether slot health status is time out or not. 200: slotHealthStatusTimeoutCleared: =============== 201: advaTemperature: To detect whether current chassis temperature is less than chassis temperature threshold or not. 202: advaTemperatureNo: =============== 203: advaPSUFailure: To detect whether ADVA system's power supply unit has a failure or not. 204: advaPSUFailureNo: =============== 205: advaFanFailure: To detect whether ADVA system's FAN has a failure or not. 206: advaFanFailureNo: =============== 207: advaInterfaceReceiveFailure: To detect whether ADVA system's receipt has a failure or not. 208: advaInterfaceReceiveFailureNo: =============== 209: advaInterfaceOpticalThreshold: To detect whether Adva system's optical receive power level is less than optical threshold or not. 210: advaInterfaceOpticalThresholdNo: =============== 211: advaInterfaceTransmitFault: To detect whether ADVA system's transmission has a failure or not. 212: advaInterfaceTransmitFaultNo: =============== 213: dvaInterfaceMisconfiguration: To detect whether ADVA system's interface is configured rightly or not. 214: advaInterfaceMisconfigurationNo: =============== 215: advaInterfaceSFPMismatch: To detect whether ADVA system's SFP interface is mismatched or not. 216: advaInterfaceSFPMismatchNo: =============== 217: advaVoltageLow: To detect whether ADVA system's current voltage is less than voltage threshold or not. 218: advaVoltageLowNo: =============== 219: advaVoltageHigh: To detect whether ADVA system's current voltage is greater than voltage threshold or not. 220: advaVoltageHighNo: =============== 301: erpDomainLotp: To detect whether LOTP(Loss of Test Packet) exists a domain of ERP or not. The Loss of Test Packet defect is defined when a node does not receive any test packet at any of its ports for a period of 3 times. 302: erpDomainLotpNo: =============== 303: erpDomainULotp: To detect whether undirectional LOTP(Loss of Test Packet) exists a domain of ERP or not. The Loss of Test Packet defect is defined when a RM node of one domain does not receive any test packet at one port for a period of 3 times. 304: erpDomainULotpNo: =============== 305: erpDomainMultipleRM: To detect whether Multiple RM node is supported or not. The defect is raised when a RM node receives its own test packets with an Ack destination address field with a non-zero value. 306: erpDomainMultipleRMNo: =============== 307: erpDomainRMNodeReacheablity: To detect whether RM reachability is raised or not. The detection of multiple failures indicates that the ring is segmented and that the RM Node is unreacheable. This is only possible at normal ring nodes isolated from the RM node. 308: erpDomainRMNodeReacheablityNo: =============== 391: startupConfigLoadEnded: To detect whether startup configuration load is ended. =============== 401: eponOnuDeregister: To detect whether ONU is registered into OLT or not. That is, ONU that its operation is service on should be sent registration information to OLT. 402: eponOnuRegister: =============== 403: eponOnuRegistrationError: To detect whether ONU is failed registeration process into OLT. 404: eponOnuNoRegistrationError: =============== 405: eponBadEncryptionKey: To detect wwhether the encryption key is valid or not. A message between ONU and OLT is encrypted using random encryption key. There is that the encryption key is invalid as transmission failure from time to time. 406: eponNoBadEncryptionKey: =============== 407: eponLlidMistmatch: To detect whether Llid of message between ONU and OLT is valid or not. On registering, ONU informs unique ID to OLT. And then, all communication between ONU and OLT must use the unique ID. The unique ID is called Llid. 408: eponNoLlidMismatch: =============== 409: eponTooManyRegister: To detect whether the registered ONU per 1 OLT is greater than 32 or not. That is, ONU can be registered from 1 to the maximum 32 at 1 OLT. 410: eponNoTooManyRegister: =============== 411: eponDyingGASP: To detect whether a ONU is down from dying gasp or not. A ONU could be changed to down state as a number of reasons. By the way, ONU that is changed to down as dying gasp would be sent dying gasp signal to OLT and then ONU's link would be changed to down. 412: eponNoDyingGASP: =============== 413: eponOnuErrFramePeriod: 414: eponOnuNoErrFramePeriod: =============== 415: eponOnuErrFrame: 416: eponOnuNoErrFrame: =============== 417: eponOnuErrFrameSecondSummary: 418: eponOnuNoErrFrameSecondSummary: =============== 419: eponOnuLastOnuDeregister: To detect whether a deregistered ONU is last ONU or not. If a deregistered ONU is last ONU, the OLT would be changed to serviceable status. 420: eponOnuNoLastOnuDeregister: =============== 421: eponOltCableDown: 422: eponOltRecoverCableDown: =============== 501: autoCLIStart: To detect whether the scheduled auto CLI is started or not. 502: autoCLINoStart: =============== 503: autoCLIComplete: To detect whether the scheduled auto CLI is completed or not. 504: autoCLINoComplete: =============== 505: autoCLIRemoveOutputFile: To detect whether the result file of the scheduled auto CLI is removed or not. The reason that the result file is removed is that the configured file size for the result is less than the stored result file size. If so, the oldest file would be removed before everything. 506: autoCLINoRemoveOutputFile: =============== 507: autoResetSystem: To detect whether the system is restarted or not. The conditions that system is restarted is that ping loss threshold is less than current ping loss count during the configured interval and that current free memory size is less than configured free memory size. 508: autoResetNoSystem: =============== 509: autoResetPingReplyLoss: To detect whether ping reply from the designated network node is received or not. Operator designates any gateway system that can communicate to detect current network environment. System sends ICMP packet to the designated gateway system periodically. If the system doesn't receive ping reply packet within any interval, operator recognizes that the system can't communicate any more because of some problems of the system. 510: autoResetNoPingReplyLoss: =============== 511: autoResetMemoryLeakDetect: To detect whether current free memory size is less than the configured free memory size or not. Periodically, free memory size is checked to confirm system availability. 512: autoResetNoMemoryLeakDetect: =============== 601: arulePacketDropDetect: To detect whether it is dropped some packet by arule or not. 602: arulePacketDropRelease: =============== 620: bME1CardNoDetect: 621: clearBME1CardNoDetect: =============== 622: bME1CardAFEerror: 623: clearBME1CardAFEerror: =============== 624: bME1CardIFEerror: 625: clearBME1CardIFEerror: =============== 626: bME1CardFWerror: 627: clearBME1CardFWerror: =============== 628: bME1CardPROVerror: 629: clearBME1CardPROVerror: =============== 630: bME1CrashDetect: 631: clearBME1CrashDetect: =============== 632: bME2CardNoDetect: 633: clearBME2CardNoDetect: =============== 634: bME2CardAFEerror: 635: clearBME2CardAFEerror: =============== 636: bME2CardIFEerror: 637: clearBME2CardIFEerror: =============== 638: bME2CardFWerror: 639: clearBME2CardFWerror: =============== 640: bME2CardPROVerror: 641: clearBME2CardPROVerror: =============== 642: bME2CrashDetect: 643: clearBME2CrashDetect: =============== 644: bME3CardNoDetect: 645: clearBME3CardNoDetect: =============== 646: bME3CardAFEerror: 647: clearBME3CardAFEerror: =============== 648: bME3CardIFEerror: 649: clearBME3CardIFEerror: =============== 650: bME3CardFWerror: 651: clearBME3CardFWerror: =============== 652: bME3CardPROVerror: 653: clearBME3CardPROVerror: =============== 654: bME3CrashDetect: 655: clearBME3CrashDetect: =============== 656: powerFromBattery: 657: clearPowerFromBattery: =============== 658: invalidBatteryStatus: 659: clearInvalidBatteryStatus: =============== 660: batteryChargeLow: 661: clearBatteryChargeLow: =============== 662: batteryNotPresent: 663: clearBatteryNotPresent: =============== 664: voltageLow: 665: clearVoltageLow: =============== 666: tempOverThreshold: 667: clearTempOverThreshold: =============== 668: tempUnderThreshold: 669: clearTempUnderThreshold: =============== 670: cpuOverThreshold: 671: clearCpuOverThreshold: =============== 672: trafficOverload: 673: clearTrafficOverload: =============== 674: gEPONModuleNotDetect: 675: clearGEPONModuleNotDetect: =============== 676: gEPONPortOperationDown: 677: clearGEPONPortOperationDown: =============== 678: gEPONNoIncomingTraffic: 679: clearGEPONNoIncomingTraffic: =============== 680: processCrashDetect: 681: clearProcessCrashDetect: =============== 682: memoryLeakDetect: 683: clearMemoryLeakDetect: =============== 684: memoryCorrupDetect: 685: clearMemoryCorrupDetect: =============== 686: memoryLowDetect: 687: clearMemoryLowDetect: =============== 688: dataLineerror: 689: clearDataLineerror: =============== 690: addressLineerror: 691: clearAddressLineerror: =============== 692: chipsetNotDetcet: 693: clearChipsetNotDetcet: =============== 694: pciBuserror: 695: clearPciBuserror: =============== 696: securityAdminConnect: 697: clearSecurityAdminConnect: =============== 698: oNUPowerDown: 699: clearONUPowerDown: =============== 700: oNUNotRegister: 701: clearONUNotRegister: =============== 702: oNTOpticPre: 703: clearONTOpticPre: =============== 800: switchoverInitiated: =============== 801: switchoverDone: =============== 803: redConfigurationMisMatch: To detect whether redundancy configuration is mismatched. =============== 901: gponNoAuthCBU: To detect no auth CBU is detected. 902: gponDuplicateONU: To detect ONU is duplicated. 903: gponDyingGasp: To detect dying GASP is detected. 904: gponUpgradeComplete: To detect upgrade complete is detected. 905: gponDeregistered: To detect whether deregistered is detected or not. 906: gponRegistered: 907: gponRogueOnu: To detect rogue ONU is detected 908: gponOnuBatteryEvent: To detect whether ONU battery event is detected or not. 909: clearGponOnuBetteryEvent: 910: gponOnuPortOperStatus: To detectONU port operation statue is chagned. 911: gponTransceiverChanged: To detect transceiver is changed. 912: gponOltLosOn: To detect whether OLT LOS is on or off 913: gponOltLosOff: 914: gponOltLosiOn: To detect whether OLT LOSI is on or off 915: gponOltLosiOff: 916: gponDyingGaspOn: To detect whether dying GASP is on or off 917: gponDyingGaspOff: 918: gponOntOSUpgradeStatus: To detect ONT OS upgrade status is changed. 919: gponOntBLUpgradeStatus: To detect BL upgrade status is changed. 920: gponOltRxPowerLoss: To detect OLT RX power is loss. 921: gponOltRxPowerDetected: To detect OLT RX power status is changed. 922: gponOnuTemperatureHighOverThreshold: To detect whether ONU temperature exceeds high threshold or not. 923: gponOnuTemperatureHighFallThreshold: 924: gponOnuTemperatureLowOverThreshold: To detect whether ONU temperature belows low threshold or not. 925: gponOnuTemperatureLowFallThreshold: 926: gponOnuCpuOverThreshold: To detect whether ONU CPU exceeds threshold or not. 927: gponOnuCpuFallThreshold: 928: gponOnuMemoryOverThreshold: To detect whether memory exceeds threshold or not. 929: gponOnuMemoryFallThreshold: 930: gponOnuI2cFail: To detect ONU L2C fail is detected. 931: gponOnuRxOpticLowThreshAlarmOn: To detect whether ONU RX optic belows low threshold or not. 932: gponOnuRxOpticLowThreshAlarmOff: 933: gponOnuRxOpticHighThreshAlarmOn: To detect whether ONU RX optic exceeds high threshold or not. 934: gponOnuRxOpticHighThreshAlarmOff: 935: gponOltLOFIOn: To detect whether OLT LOFL is on or off 936: gponOltLOFIOff: 937: gponOltDOWOn: To detect whether OLT DOW is on or off 938: gponOltDOWOff: 939: gponOltSFOn: To detect whether OLT SF is on or off 940: gponOltSFOff: 941: gponOltSDOn: To detect whether OLT SD is on or off 942: gponOltSDOff: 943: gponOltLCDGIOn: To detect whether OLT LCDGL is on or off 944: gponOltLCDGIOff: 945: gponOltRDOn: To detect whether OLT RD is on or off 946: gponOltRDOff: 947: gponOltSUFOn: To detect whether OLT SUF is on or off 948: gponOltSUFOff: 949: gponOltLOAOn: To detect whether OLT LOA is on or off 950: gponOltLOAOff: 951: gponOltLOAMIOn: To detect whether OLT LOAML is on or off 952: gponOltLOAMIOff: 953: gponOltMEMOn: To detect whether OLT MEM is on or off 954: gponOltMEMOff: 955: gponOltPEEOn: To detect whether OLT PEE is on or off 956: gponOltPEEOff: 957: gponOltPSTOn: To detect whether OLT PST is on or off 958: gponOltPSTOff: 959: gponOltERROn: To detect whether OLT ERR is on or off 960: gponOltERROff: 961: gponOltREIOn: To detect whether OLT REI is on or off 962: gponOltREIOff: 963: gponAntiSpoofingDupPortOn: To detect whether anti spoofing port is duplicated or not. 964: gponAntiSpoofingDupPortOff: 965: gponRedundancySwitchOver: To detect redundancy switchover is changed. 966: gponDuplicatedRangingResponse: To detect ranging response is changed. 967: gponOnuPortOpticModuleRemove: To detect whether ONU port optic module is removed or installed. 968: gponOnuPortOpticModuleInstall: 969: gponOnuOMCCProblemDetected: To detect whether ONU OMCC problem is detected or not. 970: gponOnuOMCCProblemCleared: 971: gponOltFixedTcontAlarmOn: To detect whether OLT fixed Tcont alarm is on or off. 972: gponOltFixedTcontAlarmOff: 973: gponOltDynamicTcontAlarmOn: To detect whether OLT dynamic Tcont alarm is on or off. 974: gponOltDynamicTcontAlarmOff: 975: gponOltPortCountAlarmOn: To detect whether OLT port count alarm is on or off. 976: gponOltPortCountAlarmOff: 977: gponOltCableDownAlarmOn: To detect whether OLT cable down alarm is on or off. 978: gponOltCableDownAlarmOff: 979: gponOltDeactiveMonitorAlarmOn: To detect whether deactive monitor alarm is on or off. 980: gponOltDeactiveMonitorAlarmOff: 981: gponOltDfiOn: To detect whether OLT DFI is on or off. 982: gponOltDfiOff: 984: gponOltTransceiverPortChanged: To detect OLT transeiver port is changed. 985: gponOnuPortOperStatusDown: To detect whether ONU port operation status is down or up. 986: gponOnuPortOperStatusUp:: =============== 1101: emLogDefectCPUHighOver: To detect whether EM log detect CPU exceeds threshold or not. 1102: emLogDefectCPUHighUnder: 1103: emLogTemperHighOver: To detect whether EM log temperature exceeds high threshold or not. 1104: emLogTemperHighUnder: 1105: emLogTemperLowUnder: To detect whether EM log CPU belows low threshold or not. 1106: emLogTemperLowOver: 1107: emLogMemLowUnder: To detect whether EM log memory belows low threshold or not. 1108: emLogMemLowOver: 1109: emLogFanFail: To detect whether EM log fan status is failed or not. 1110: emLogFanFailCleared: 1111: emLogPhyCRCFail: To detect whether EM log physical CRC is failed or not. 1112: emLogPhyCRCFailCleared: 1113: emLogPhyDetectFail: To detect whether EM log physical status is failed or not. 1114: emLogPhyDetectFailCleared: 1115: emLogSFUMateInitFail: To detect whether EM log SFU mate initialization is failed or not. 1116: emLogSFUMateInitFailCleared: 1117: emLogDaemonHealthBad: To detect whether EM log daemon health is bad or not. 1118: emLogDaemonHealthBadCleared: 1119: emLogGPIURavenLinkDown: To detect whether EM log GPIU RAVEN link is down or not. 1120: emLogGPIURavenLinkDownCleared: =============== 1151: slotNosUpgradeStart: To detect whether slot NOS upgrade is started or ended. 1152: slotNosUpgradeEnd: =============== 1331: gponOnuAniVoltageLowThreshAlarmOn: To detect whether ONU ANI voltage belows low threshold or not. 1332: gponOnuAniVoltageLowThreshAlarmOff: 1333: gponOnuAniVoltageHighThreshAlarmOn: To detect whether ONU ANI voltage exceeds high threshold or not. 1334: gponOnuAniVoltageHighThreshAlarmOff: 1335: gponOnuAniTemperatureLowThreshAlarmOn: To detect whether ONU ANI temperature belows low threshold or not. 1336: gponOnuAniTemperatureLowThreshAlarmOff: 1337: gponOnuAniTemperatureHighThreshAlarmOn: To detect whether ONU ANI temperature exceeds high threshold or not. 1338: gponOnuAniTemperatureHighThreshAlarmOff: 1339: gponOnuAniTxBiasLowThreshAlarmOn: To detect whether ONU ANI TX bias belows low threshold or not. 1340: gponOnuAniTxBiasLowThreshAlarmOff: 1341: gponOnuAniTxBiasHighThreshAlarmOn: To detect whether ONU ANI TX bias exceeds high threshold or not. 1342: gponOnuAniTxBiasHighThreshAlarmOff: 1343: gponOnuAniTxpowerLowThreshAlarmOn: To detect whether ONU ANI TX power belows low threshold or not. 1344: gponOnuAniTxpowerLowThreshAlarmOff: 1345: gponOnuAniTxpowerHighThreshAlarmOn: To detect whether ONU ANI TX power exceeds high threshold or not. 1346: gponOnuAniTxpowerHighThreshAlarmOff:" ::= { sleAlarmHistoryEntry 2 } sleAlarmHistorySeverity OBJECT-TYPE SYNTAX INTEGER { critical(1), major(2), minor(3), warning(4), intermediate(5) } MAX-ACCESS read-only STATUS current DESCRIPTION " The severity of alarm. " ::= { sleAlarmHistoryEntry 3 } sleAlarmHistoryText OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Textual description of specific problem reported by alarming. To be discussed: Option is to define an alarm for every problem " ::= { sleAlarmHistoryEntry 4 } sleAlarmHistoryTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The severity of alarm. " ::= { sleAlarmHistoryEntry 5 } sleAlarmHistorySeqNum OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Sequence number for the alarm synchronization. This value has a number to be used for the next alarm trap." ::= { sleAlarmHistoryEntry 6 } sleAlarmHistoryPairType OBJECT-TYPE SYNTAX INTEGER { pair(0), mono(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type is whether alarm trap is pair or mono." ::= { sleAlarmHistoryEntry 7 } sleAlarmHistoryControl OBJECT IDENTIFIER ::= { sleAlarmHistory 2 } sleAlarmHistoryControlRequest OBJECT-TYPE SYNTAX INTEGER { clearAlarmHistory(1) } MAX-ACCESS read-write STATUS current DESCRIPTION " This attribute identifies the control commands. updateAlarmList: the NE updates entries of alarms in the sleAlarmListTable after having changed alarm severities of alarms (due to change profile pointers in managed entities or after modification of alarm severities in profiles). This command should be applied once after having finisled modifications of severties. modifyAlarmSeverity: modifies the severity of an alarm in specific profile. createAlarmSeverityProfile: creates a new profile with default severities. The severities then have to be modified with command changeAlarmSeverity. deleteAlarmSeverityProfile: deletes a profile. Profile 1 is not allowed to be deleted. Notifications : none " ::= { sleAlarmHistoryControl 1 } sleAlarmHistoryControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION " The status of a control request. " ::= { sleAlarmHistoryControl 2 } sleAlarmHistoryControlTimer OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION " The maximum wait time for the manager for command ending. For long running commands. The manager reads this value from the DSLAM. " ::= { sleAlarmHistoryControl 3 } sleAlarmHistoryControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION " The time stamp of the last command (end of command). " ::= { sleAlarmHistoryControl 4 } sleAlarmHistoryControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION " The result of the last user command. " ::= { sleAlarmHistoryControl 5 } sleAlarmHistoryNotification OBJECT IDENTIFIER ::= { sleAlarmHistory 3 } sleAlarmHistoryCleared NOTIFICATION-TYPE OBJECTS { sleAlarmHistoryControlRequest, sleAlarmHistoryControlTimeStamp, sleAlarmHistoryControlReqResult } STATUS current DESCRIPTION "Description." ::= { sleAlarmHistoryNotification 1 } sleEfmOam OBJECT IDENTIFIER ::= { sleFaultMgmt 5 } sleEfmOamTable OBJECT-TYPE SYNTAX SEQUENCE OF SleEfmOamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleEfmOam 1 } sleEfmOamEntry OBJECT-TYPE SYNTAX SleEfmOamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleOamPortIndex } ::= { sleEfmOamTable 1 } SleEfmOamEntry ::= SEQUENCE { sleOamPortIndex INTEGER, sleOamMuxAction INTEGER, sleOamParAction INTEGER, sleOamAdminState INTEGER, sleOamMode INTEGER, sleOamUnidirectionMode INTEGER, sleOamFunctionsSupported BITS, sleOamPeerStatus INTEGER, sleOamPeerMacAddress MacAddress, sleOamPeerMode INTEGER, sleOamPeerFunctionsSupported BITS, sleOamRemLoopback INTEGER, sleOamRemLoopbackCnt INTEGER, sleOamLm INTEGER, sleOamLmAction INTEGER, sleOamLmFrameWindow INTEGER, sleOamLmFrameThresh INTEGER, sleOamLmFrameTotal Counter64, sleOamLmFramePeriodWindow Integer32, sleOamLmFramePeriodThresh Integer32, sleOamLmFramePeriodTotal Counter64, sleOamLmFrameSecondSummaryWindow Integer32, sleOamLmFrameSecondSummaryThresh Integer32, sleOamLmFrameSecondSummaryTotal Counter64, sleOamLmSymbolPeriodWindow INTEGER, sleOamLmSymbolPeriodThresh INTEGER, sleOamLmSymbolPeriodTotal Counter64, sleOamLmRemSeqNum Integer32, sleOamLmRemFrameLength Integer32, sleOamLmRemFrameTimeStamp TimeTicks, sleOamLmRemFrameWindow Integer32, sleOamLmRemFrameThresh Integer32, sleOamLmRemFrameErrors Integer32, sleOamLmRemFrameErrorRunTotal Counter64, sleOamLmRemFrameEventRunTotal Integer32, sleOamLmRemFramePeriodLength Integer32, sleOamLmRemFramePeriodTimeStamp TimeTicks, sleOamLmRemFramePeriodWindow Integer32, sleOamLmRemFramePeriodThresh Integer32, sleOamLmRemFramePeriodErrors Integer32, sleOamLmRemFramePeriodErrorRunTotal Counter64, sleOamLmRemFramePeriodEventRunTotal Integer32, sleOamLmRemFrameSecondSummaryLength Integer32, sleOamLmRemFrameSecondSummaryTimeStamp TimeTicks, sleOamLmRemFrameSecondSummaryWindow Integer32, sleOamLmRemFrameSecondSummaryThresh Integer32, sleOamLmRemFrameSecondSummaryErrors Integer32, sleOamLmRemFrameSecondSummaryErrorRunTotal Integer32, sleOamLmRemFrameSecondSummaryEventRunTotal Integer32, sleOamLmRemSymbolPeriodLength Integer32, sleOamLmRemSymbolPeriodTimeStamp TimeTicks, sleOamLmRemSymbolPeriodWindow Counter64, sleOamLmRemSymbolPeriodThresh Counter64, sleOamLmRemSymbolPeriodErrors Counter64, sleOamLmRemSymbolPeriodErrorRunTotal Counter64, sleOamLmRemSymbolPeriodEventRunTotal Counter64 } sleOamPortIndex OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleEfmOamEntry 1 } sleOamMuxAction OBJECT-TYPE SYNTAX INTEGER { fwd(1), discard(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This value governs the flow of frames from the MAC client to the Muliplexer function." ::= { sleEfmOamEntry 2 } sleOamParAction OBJECT-TYPE SYNTAX INTEGER { fwd(1), lb(2), discard(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This value governs the flow of non-OAMPDUs within the Parser function." ::= { sleEfmOamEntry 3 } sleOamAdminState OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to provision the default administrative OAM mode for this interface." ::= { sleEfmOamEntry 4 } sleOamMode OBJECT-TYPE SYNTAX INTEGER { passive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object configures the mode of OAM operation for this Ethernet like interface." ::= { sleEfmOamEntry 5 } sleOamUnidirectionMode OBJECT-TYPE SYNTAX INTEGER { notAvaliable(-2), disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleEfmOamEntry 6 } sleOamFunctionsSupported OBJECT-TYPE SYNTAX BITS { unidirectionalSupport(0), loopbackSupport(1), eventSupport(2), variableSupport(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The OAM functions supported on this Ethernet like interface." ::= { sleEfmOamEntry 7 } sleOamPeerStatus OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates whether the information in this row should be considered valid." ::= { sleEfmOamEntry 8 } sleOamPeerMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The MAC address of the peer OAM entity." ::= { sleEfmOamEntry 9 } sleOamPeerMode OBJECT-TYPE SYNTAX INTEGER { passive(0), active(1), unknown(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The mode Info of the OAM peer as reflected in the latest Information OAMPDU received with a Local Information TLV." ::= { sleEfmOamEntry 10 } sleOamPeerFunctionsSupported OBJECT-TYPE SYNTAX BITS { unidirectionalSupport(0), loopbackSupport(1), eventSupport(2), variableSupport(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The OAM functions supported on this Ethernet like interface." ::= { sleEfmOamEntry 11 } sleOamRemLoopback OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleEfmOamEntry 12 } sleOamRemLoopbackCnt OBJECT-TYPE SYNTAX INTEGER (1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of test Packet" ::= { sleEfmOamEntry 13 } sleOamLm OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicates whether Link-Monitor supports or not for port index." ::= { sleEfmOamEntry 14 } sleOamLmAction OBJECT-TYPE SYNTAX INTEGER { syslog(0), snmpTrap(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Action of Link-Monitor for port index." ::= { sleEfmOamEntry 15 } sleOamLmFrameWindow OBJECT-TYPE SYNTAX INTEGER (10..600) UNITS "100 ms" MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Window size of Errored Frame. Default : 10, Unit : 100ms " ::= { sleEfmOamEntry 16 } sleOamLmFrameThresh OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Threshold size of Errored Frame. Default: 1 " ::= { sleEfmOamEntry 17 } sleOamLmFrameTotal OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Total Count of Errored Frame" ::= { sleEfmOamEntry 18 } sleOamLmFramePeriodWindow OBJECT-TYPE SYNTAX Integer32 (1000..200000000) MAX-ACCESS read-only STATUS current DESCRIPTION "This value is size of Errored Period Window. Default : 1000000 frames " ::= { sleEfmOamEntry 19 } sleOamLmFramePeriodThresh OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This value is size of Errored Period Threshold. Default : 10 " ::= { sleEfmOamEntry 20 } sleOamLmFramePeriodTotal OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Total Count of Errored Period Frame" ::= { sleEfmOamEntry 21 } sleOamLmFrameSecondSummaryWindow OBJECT-TYPE SYNTAX Integer32 (10..900) UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Window size of errored frame in a second Default : 60 secs " ::= { sleEfmOamEntry 22 } sleOamLmFrameSecondSummaryThresh OBJECT-TYPE SYNTAX Integer32 (0..900) MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Threshold size of errored frame in a second Default: 1 " ::= { sleEfmOamEntry 23 } sleOamLmFrameSecondSummaryTotal OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Total Count of Errored Frame Second" ::= { sleEfmOamEntry 24 } sleOamLmSymbolPeriodWindow OBJECT-TYPE SYNTAX INTEGER (1..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the window size of symbol errors. Default: 625 millions, Unit: 1 million " ::= { sleEfmOamEntry 25 } sleOamLmSymbolPeriodThresh OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Threshold size of symbol errors Default : 1 " ::= { sleEfmOamEntry 26 } sleOamLmSymbolPeriodTotal OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Total Count of Symbol errors" ::= { sleEfmOamEntry 27 } sleOamLmRemSeqNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Sequence Number for event" ::= { sleEfmOamEntry 28 } sleOamLmRemFrameLength OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Length of Errored Frame" ::= { sleEfmOamEntry 29 } sleOamLmRemFrameTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the TimeStamp of Errored Frame" ::= { sleEfmOamEntry 30 } sleOamLmRemFrameWindow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Window Size of Errored Frame" ::= { sleEfmOamEntry 31 } sleOamLmRemFrameThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Threshold Size of Errored Frame" ::= { sleEfmOamEntry 32 } sleOamLmRemFrameErrors OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Count of Errored Frame" ::= { sleEfmOamEntry 33 } sleOamLmRemFrameErrorRunTotal OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Total Count of Errored Frame" ::= { sleEfmOamEntry 34 } sleOamLmRemFrameEventRunTotal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Total Count of Errored Frame Event" ::= { sleEfmOamEntry 35 } sleOamLmRemFramePeriodLength OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Length of Errored Frame Period" ::= { sleEfmOamEntry 36 } sleOamLmRemFramePeriodTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the TimeStamp of Errored Frame Period" ::= { sleEfmOamEntry 37 } sleOamLmRemFramePeriodWindow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Window Size of Errored Frame Period" ::= { sleEfmOamEntry 38 } sleOamLmRemFramePeriodThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Threshold Size of Errored Frame Period" ::= { sleEfmOamEntry 39 } sleOamLmRemFramePeriodErrors OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Count of Errored Frame Period" ::= { sleEfmOamEntry 40 } sleOamLmRemFramePeriodErrorRunTotal OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Total Count of Errored Frame Period" ::= { sleEfmOamEntry 41 } sleOamLmRemFramePeriodEventRunTotal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Total Count of Errored Frame Period Event" ::= { sleEfmOamEntry 42 } sleOamLmRemFrameSecondSummaryLength OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Length of Errored Frame Second Summary" ::= { sleEfmOamEntry 43 } sleOamLmRemFrameSecondSummaryTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the TimeStamp of Errored Frame Second Summary" ::= { sleEfmOamEntry 44 } sleOamLmRemFrameSecondSummaryWindow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Window size of Errored Frame Second Summary" ::= { sleEfmOamEntry 45 } sleOamLmRemFrameSecondSummaryThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Threshold size of Errored Frame Second Summary" ::= { sleEfmOamEntry 46 } sleOamLmRemFrameSecondSummaryErrors OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Count of Errored Frame Second Summary" ::= { sleEfmOamEntry 47 } sleOamLmRemFrameSecondSummaryErrorRunTotal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Total Count of Errored Frame Second Summary" ::= { sleEfmOamEntry 48 } sleOamLmRemFrameSecondSummaryEventRunTotal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Total Count of Errored Frame Second Summary Event" ::= { sleEfmOamEntry 49 } sleOamLmRemSymbolPeriodLength OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Length of Errored Symbols" ::= { sleEfmOamEntry 50 } sleOamLmRemSymbolPeriodTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the TimeStamp of Errored Symbols" ::= { sleEfmOamEntry 51 } sleOamLmRemSymbolPeriodWindow OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Window size of Errored Symbols" ::= { sleEfmOamEntry 52 } sleOamLmRemSymbolPeriodThresh OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Threshold size of Errored Symbols" ::= { sleEfmOamEntry 53 } sleOamLmRemSymbolPeriodErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Count of Errored Symbols" ::= { sleEfmOamEntry 54 } sleOamLmRemSymbolPeriodErrorRunTotal OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Total Count of Errored Symbols" ::= { sleEfmOamEntry 55 } sleOamLmRemSymbolPeriodEventRunTotal OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Total Count of Errored Symbols Event" ::= { sleEfmOamEntry 56 } sleEfmOamControl OBJECT IDENTIFIER ::= { sleEfmOam 2 } sleOamControlRequest OBJECT-TYPE SYNTAX INTEGER { setEfmOamPortProfile(1), setEfmOamPortRemLoopback(2), setEfmOamPortLinkMonitor(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The MIB object for the user command.." ::= { sleEfmOamControl 1 } sleOamControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the status of a user command group, used for block commands while a command execution in process." ::= { sleEfmOamControl 2 } sleOamControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum command duration time in case of long running" ::= { sleEfmOamControl 3 } sleOamControlTimeStamp OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "Time stamp attribute set at end of command." ::= { sleEfmOamControl 4 } sleOamControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION "Command result attribute" ::= { sleEfmOamControl 5 } sleOamControlIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleEfmOamControl 6 } sleOamControlPortAdminState OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to provision the default administrative OAM mode for this interface." ::= { sleEfmOamControl 7 } sleOamControlPortMode OBJECT-TYPE SYNTAX INTEGER { passive(0), active(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object configures the mode of OAM operation for this Ethernet like interface." ::= { sleEfmOamControl 8 } sleOamControlPortUnidirectionMode OBJECT-TYPE SYNTAX INTEGER { notAvaliable(-2), disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleEfmOamControl 9 } sleOamControlPortRemLoopback OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1), start(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The value indicates an optional data link layer frame-level loopback mode, which is controlled remotely." ::= { sleEfmOamControl 10 } sleOamControlRemLoopbackPkCnt OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of test Packet" ::= { sleEfmOamControl 11 } sleOamControlLm OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This value indicates whether Link-Monitor supports or not for port index." ::= { sleEfmOamControl 12 } sleOamControlLmAction OBJECT-TYPE SYNTAX INTEGER { syslog(0), snmpTrap(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Action of Link-Monitor for port index." ::= { sleEfmOamControl 13 } sleOamControlLmFrameWindow OBJECT-TYPE SYNTAX INTEGER (10..600) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This value is the Window size of Errored Frame. Default : 30 secs " ::= { sleEfmOamControl 14 } sleOamControlLmFrameThresh OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This value is the Threshold size of Errored Frame. Default: 1 " ::= { sleEfmOamControl 15 } sleOamControlLmFramePeriodWindow OBJECT-TYPE SYNTAX INTEGER (1000..200000000) MAX-ACCESS read-write STATUS current DESCRIPTION "This value is size of Errored Period Window. Default : 1000000 frames " ::= { sleEfmOamControl 16 } sleOamControlLmFramePeriodThresh OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This value is size of Errored Period Threshold. Default : 10 " ::= { sleEfmOamControl 17 } sleOamControlLmFrameSecondSummaryWindow OBJECT-TYPE SYNTAX INTEGER (10..900) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This value is the Window size of errored frame in a second Default : 60 secs " ::= { sleEfmOamControl 18 } sleOamControlLmFrameSecondSummaryThresh OBJECT-TYPE SYNTAX INTEGER (0..900) MAX-ACCESS read-write STATUS current DESCRIPTION "This value is the Threshold size of errored frame in a second Default: 1 " ::= { sleEfmOamControl 19 } sleOamControlLmSymbolPeriodWindow OBJECT-TYPE SYNTAX INTEGER (1..1000000) MAX-ACCESS read-write STATUS current DESCRIPTION "This value is the window size of symbol errors. Default: 625 millions, Unit: 1 million " ::= { sleEfmOamControl 20 } sleOamControlLmSymbolPeriodThresh OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This value is the Threshold size of symbol errors Default : 1 " ::= { sleEfmOamControl 21 } sleEfmOamNotification OBJECT IDENTIFIER ::= { sleEfmOam 3 } sleEfmOamPortProfileChanged NOTIFICATION-TYPE OBJECTS { sleOamControlReqResult, sleOamControlTimeStamp, sleOamControlRequest, sleOamAdminState, sleOamMode, sleOamUnidirectionMode } STATUS current DESCRIPTION " " ::= { sleEfmOamNotification 1 } sleEfmOamPortRemLoopback NOTIFICATION-TYPE OBJECTS { sleOamControlRequest, sleOamControlReqResult, sleOamControlTimeStamp, sleOamRemLoopback, sleOamControlRemLoopbackPkCnt } STATUS current DESCRIPTION "Description." ::= { sleEfmOamNotification 2 } sleEfmOamPortLinkMonitorChanged NOTIFICATION-TYPE OBJECTS { sleOamControlRequest, sleOamControlReqResult, sleOamControlTimeStamp, sleOamLmFramePeriodThresh, sleOamLmFramePeriodWindow, sleOamLmFrameThresh, sleOamLmFrameWindow, sleOamLmAction, sleOamLmSymbolPeriodThresh, sleOamLmSymbolPeriodWindow, sleOamLmFrameSecondSummaryThresh, sleOamLmFrameSecondSummaryWindow, sleOamLm, sleOamPortIndex } STATUS current DESCRIPTION "Description." ::= { sleEfmOamNotification 3 } sleAdvaSystem OBJECT IDENTIFIER ::= { sleFaultMgmt 6 } sleAdvaSystemTable OBJECT-TYPE SYNTAX SEQUENCE OF SleAdvaSystemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleAdvaSystem 1 } sleAdvaSystemEntry OBJECT-TYPE SYNTAX SleAdvaSystemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleOamPortIndex } ::= { sleAdvaSystemTable 1 } SleAdvaSystemEntry ::= SEQUENCE { sleAdvaFSPOperationMode INTEGER, sleAdvaActiveNetworkInterface INTEGER, sleAdvaForceNetworkInterface INTEGER, sleAdvaReportingInterval INTEGER, sleAdvaNEMIFitted INTEGER, sleAdvaForceReset INTEGER, sleAdvaManagerAddress IpAddress, sleAdvaMinRailVoltageThreshold INTEGER, sleAdvaMaxRailVoltageThreshold INTEGER, sleAdvaTemperatureThreshold INTEGER, sleAdvaPartNumber OCTET STRING, sleAdvaSerialNumber OCTET STRING, sleAdvaFirmwareVersion OCTET STRING, sleAdvaFPGAVersion OCTET STRING, sleAdvaHardwareRevision OCTET STRING, sleAdvaCLEICode OCTET STRING, sleAdvaTemperature INTEGER, sleAdvaRailVoltage INTEGER, sleAdvaPSUStates INTEGER, sleAdvaPSUType INTEGER, sleAdvaFansFitted INTEGER, sleAdvaFanState INTEGER, sleAdvaTransmitMode INTEGER } sleAdvaFSPOperationMode OBJECT-TYPE SYNTAX INTEGER { master(1), slave(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Mode in which the FSP 150 is to operate" ::= { sleAdvaSystemEntry 1 } sleAdvaActiveNetworkInterface OBJECT-TYPE SYNTAX INTEGER { both(0), portA(1), portB(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Which of the network interfaces is the active one" ::= { sleAdvaSystemEntry 2 } sleAdvaForceNetworkInterface OBJECT-TYPE SYNTAX INTEGER { unforced(0), forceA(1), forceB(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleAdvaSystemEntry 3 } sleAdvaReportingInterval OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Repeat period in 1/10th seconds for Organisation Specific Alarm Status OAMPDU. If non-zero and there are any alarms active, repeat the last-sent AS after this interval from when it was last sent.If zero then only send on changes.As a special action, writing zero to this will cause the Alarm Status OAMPDU to be sent (poll)." ::= { sleAdvaSystemEntry 4 } sleAdvaNEMIFitted OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicator as to whether a NEMI is fitted." ::= { sleAdvaSystemEntry 5 } sleAdvaForceReset OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Writing True (1) causes the system to be reset." ::= { sleAdvaSystemEntry 6 } sleAdvaManagerAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the Management station monitoring this sytem." ::= { sleAdvaSystemEntry 7 } sleAdvaMinRailVoltageThreshold OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Threshold in mV below which the Voltage low alarm will be activated. (Alarm Configuration)" ::= { sleAdvaSystemEntry 8 } sleAdvaMaxRailVoltageThreshold OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Threshold in mV above which the Voltage high alarm will be activated. (Alarm Configuration)" ::= { sleAdvaSystemEntry 9 } sleAdvaTemperatureThreshold OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Threshold in C above which the Temperature alarm will be activated. (Alarm Configuration)" ::= { sleAdvaSystemEntry 10 } sleAdvaPartNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Part number for the chassis. (Chassis)" ::= { sleAdvaSystemEntry 11 } sleAdvaSerialNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number for the chassis. (Chassis)" ::= { sleAdvaSystemEntry 12 } sleAdvaFirmwareVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Firmware version for the chassis. (Chassis) (0-length string if unknown)." ::= { sleAdvaSystemEntry 13 } sleAdvaFPGAVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "FPGA version for the chassis. (Chassis) (0-length string if unknown)." ::= { sleAdvaSystemEntry 14 } sleAdvaHardwareRevision OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..4)) MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware revision for the chassis. (Chassis)(0-length string if unknown)." ::= { sleAdvaSystemEntry 15 } sleAdvaCLEICode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..14)) MAX-ACCESS read-only STATUS current DESCRIPTION "CLEI for the chassis. (Chassis)" ::= { sleAdvaSystemEntry 16 } sleAdvaTemperature OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Current chassis temperature in degrees C. (Chassis)" ::= { sleAdvaSystemEntry 17 } sleAdvaRailVoltage OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Current DC power rail voltage (mV). (Chassis)" ::= { sleAdvaSystemEntry 18 } sleAdvaPSUStates OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Bit-mask representing the state of the PSUs. Starting at the LSB, each failed PSU is indicated by a bit set to '1'. (Chassis)" ::= { sleAdvaSystemEntry 19 } sleAdvaPSUType OBJECT-TYPE SYNTAX INTEGER { ac(1), dc(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of PSUs fitted. (Chassis)" ::= { sleAdvaSystemEntry 20 } sleAdvaFansFitted OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Bit-mask representing which fans are fitted. Starting at the LSB, each bit set to '1' indicates a fitted fan. Knowledge of which fans ought to be fitted is assumed. (Chassis)" ::= { sleAdvaSystemEntry 21 } sleAdvaFanState OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Bit-mask representing the state of the fan. Starting at the LSB, each failed fan is indicated by a bit set to '1'. (Chassis)" ::= { sleAdvaSystemEntry 22 } sleAdvaTransmitMode OBJECT-TYPE SYNTAX INTEGER { halfDuplex(0), fullDuplex(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Electrical Interface for remote instance 4" ::= { sleAdvaSystemEntry 23 } sleAdvaSystemControl OBJECT IDENTIFIER ::= { sleAdvaSystem 2 } sleAdvaSystemControlRequest OBJECT-TYPE SYNTAX INTEGER { setAdvaSystemProfile(1), setAdvaAlarmProfile(2), setAdvaElectricalInterface(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The MIB object for the user command.." ::= { sleAdvaSystemControl 1 } sleAdvaSystemControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the status of a user command group, used for block commands while a command execution in process." ::= { sleAdvaSystemControl 2 } sleAdvaSystemControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaSystemControl 3 } sleAdvaSystemControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaSystemControl 4 } sleAdvaSystemControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaSystemControl 5 } sleAdvaSystemControlPortIndex OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaSystemControl 6 } sleAdvaSystemControlFSPOperationMode OBJECT-TYPE SYNTAX INTEGER { master(1), save(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaSystemControl 7 } sleAdvaSystemControlForceNetworkInterface OBJECT-TYPE SYNTAX INTEGER { unforced(0), forceA(1), forceB(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaSystemControl 8 } sleAdvaSystemControlReportingInterval OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaSystemControl 9 } sleAdvaSystemControlForceReset OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaSystemControl 10 } sleAdvaSystemControlMinRailVoltageThreshold OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaSystemControl 11 } sleAdvaSystemControlMaxRailVoltageThreshold OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaSystemControl 12 } sleAdvaSystemControlTemperatureThreshold OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaSystemControl 13 } sleAdvaSystemControlTransmitMode OBJECT-TYPE SYNTAX INTEGER { halfDuplex(0), fullDuplex(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaSystemControl 14 } sleAdvaSystemNotification OBJECT IDENTIFIER ::= { sleAdvaSystem 3 } sleAdvaSystemProfileChanged NOTIFICATION-TYPE OBJECTS { sleAdvaSystemControlRequest, sleAdvaSystemControlReqResult, sleAdvaSystemControlTimeStamp, sleAdvaFSPOperationMode, sleAdvaForceNetworkInterface, sleAdvaReportingInterval, sleAdvaForceReset } STATUS current DESCRIPTION "Description." ::= { sleAdvaSystemNotification 1 } sleAdvaAlarmProfileChanged NOTIFICATION-TYPE OBJECTS { sleAdvaSystemControlRequest, sleAdvaSystemControlReqResult, sleAdvaSystemControlTimeStamp, sleAdvaMinRailVoltageThreshold, sleAdvaMaxRailVoltageThreshold, sleAdvaTemperatureThreshold } STATUS current DESCRIPTION "Description." ::= { sleAdvaSystemNotification 2 } sleAdvaElectricalInterfaceChanged NOTIFICATION-TYPE OBJECTS { sleAdvaSystemControlRequest, sleAdvaSystemControlReqResult, sleAdvaSystemControlTimeStamp, sleAdvaTransmitMode } STATUS current DESCRIPTION "Description." ::= { sleAdvaSystemNotification 3 } sleAdvaGeneral OBJECT IDENTIFIER ::= { sleFaultMgmt 7 } sleAdvaGeneralTable OBJECT-TYPE SYNTAX SEQUENCE OF SleAdvaGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleAdvaGeneral 1 } sleAdvaGeneralEntry OBJECT-TYPE SYNTAX SleAdvaGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleOamPortIndex, sleAdvaRemInstance } ::= { sleAdvaGeneralTable 1 } SleAdvaGeneralEntry ::= SEQUENCE { sleAdvaRemInstance INTEGER, sleAdvaOperationalStatus INTEGER, sleAdvaLineSpeed Integer32, sleAdvaMACAddress MacAddress, sleAdvaConnectorType INTEGER, sleAdvaAutonegiotation INTEGER, sleAdvaLinkLossForwarding INTEGER, sleAdvaAdminState INTEGER, sleAdvaRemoteInterfaceIndex INTEGER, sleAdvaUserDefinedString OCTET STRING, sleAdvaRemoteSignalling INTEGER, sleAdvaConfiguration INTEGER, sleAdvaLocalTechnologyAbility BITS, sleAdvaAdvertisedTechnologyAbility BITS, sleAdvaReceivedTechnologyAbility BITS, sleAdvaLocalSectorAbility BITS, sleAdvaAdvertisedSectorAbility BITS, sleAdvaReceivedSectorAbility BITS, sleAdvaDuplexCapabilities INTEGER, sleAdvaPHYType INTEGER, sleAdvaPHYTypeList BITS, sleAdvaMIIDetect INTEGER, sleAdvaPHYState INTEGER, sleAdvaGoodFramesTransmitted Integer32, sleAdvaSingleCollisionFrames Integer32, sleAdvaMultipleCollisionFrames Integer32, sleAdvaGoodFramesReceived Integer32, sleAdvaFCSErrors Integer32, sleAdvaAlignmentErrors Integer32, sleAdvaFramesTooLong Integer32, sleAdvaBytesTransmitted Integer32, sleAdvaBytesReceived Integer32, sleAdvaSymbolErrors Integer32 } sleAdvaRemInstance OBJECT-TYPE SYNTAX INTEGER (0..4) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleAdvaGeneralEntry 1 } sleAdvaOperationalStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), outofservice(3), unknown(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "encoding TBD. (General)" ::= { sleAdvaGeneralEntry 2 } sleAdvaLineSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Line speed in kbit/s. (General)" ::= { sleAdvaGeneralEntry 3 } sleAdvaMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The Ethernet address of the interface. (General)" ::= { sleAdvaGeneralEntry 4 } sleAdvaConnectorType OBJECT-TYPE SYNTAX INTEGER { sc(1), fc(2), mu(3), rj45(4), lu(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "encoding TBD. (General)" ::= { sleAdvaGeneralEntry 5 } sleAdvaAutonegiotation OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Autonegiotation package - aAutoNegAdminState. (General)Enabled or disabled. " ::= { sleAdvaGeneralEntry 6 } sleAdvaLinkLossForwarding OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "When enabled access interface is brought down, when both network interfaces are down. (General)" ::= { sleAdvaGeneralEntry 7 } sleAdvaAdminState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Whether the interface is available. (General)" ::= { sleAdvaGeneralEntry 8 } sleAdvaRemoteInterfaceIndex OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the remote interface the interface is connected to. (General)" ::= { sleAdvaGeneralEntry 9 } sleAdvaUserDefinedString OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "User definable string associated with interface. (General)" ::= { sleAdvaGeneralEntry 10 } sleAdvaRemoteSignalling OBJECT-TYPE SYNTAX INTEGER { detected(1), notdetected(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Autonegiotation package - aAutoNegRemoteSignalling. (AutoNego)" ::= { sleAdvaGeneralEntry 11 } sleAdvaConfiguration OBJECT-TYPE SYNTAX INTEGER { other(1), configuring(2), completed(3), disabled(4), parallelDetectFail(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Autonegiotation package - aAutoNegConfig. (AutoNego)Indicates whether Auto-Negotiation signaling is in progress or has completed." ::= { sleAdvaGeneralEntry 12 } sleAdvaLocalTechnologyAbility OBJECT-TYPE SYNTAX BITS { global(0), unknown(1), base10T(2), base10TFD(3), base100T4(4), base100TX(5), base100TXFD(6), fdxpause(7), fdxapause(8), fdxspause(9), fdxbpause(10), base100T2(11), base100T2FD(12), base1000X(13), base1000XFD(14), base1000T(15), base1000TFD(16), remFault1(17), remFault2(18), isoEthernet(19) } MAX-ACCESS read-only STATUS current DESCRIPTION "Autonegiotation package - aAutoNegLocalTechnologyAbility. (AutoNego)This indicates the technology ability of the local device" ::= { sleAdvaGeneralEntry 13 } sleAdvaAdvertisedTechnologyAbility OBJECT-TYPE SYNTAX BITS { global(0), unknown(1), base10T(2), base10TFD(3), base100T4(4), base100TX(5), base100TXFD(6), fdxpause(7), fdxapause(8), fdxspause(9), fdxbpause(10), base100T2(11), base100T2FD(12), base1000X(13), base1000XFD(14), base1000T(15), base1000TFD(16), remFault1(17), remFault2(18), isoEthernet(19) } MAX-ACCESS read-only STATUS current DESCRIPTION "Autonegiotation package - aAutoNegAdvertisedTechnologyAbility. (AutoNego)The advertised technology ability of the local device." ::= { sleAdvaGeneralEntry 14 } sleAdvaReceivedTechnologyAbility OBJECT-TYPE SYNTAX BITS { global(0), unknown(1), base10T(2), base10TFD(3), base100T4(4), base100TX(5), base100TXFD(6), fdxpause(7), fdxapause(8), fdxspause(9), fdxbpause(10), base100T2(11), base100T2FD(12), base1000X(13), base1000XFD(14), base1000T(15), base1000TFD(16), remFault1(17), remFault2(18), isoEthernet(19) } MAX-ACCESS read-only STATUS current DESCRIPTION "Autonegiotation package - aAutoNegReceivedTechnologyAbility. (AutoNego)Indicates the advertised technology ability of the remote hardware." ::= { sleAdvaGeneralEntry 15 } sleAdvaLocalSectorAbility OBJECT-TYPE SYNTAX BITS { other(0), ethernet(1), isoethernet(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Autonegiotation package - aAutoNegLocalSectorAbility. (AutoNego)" ::= { sleAdvaGeneralEntry 16 } sleAdvaAdvertisedSectorAbility OBJECT-TYPE SYNTAX BITS { other(0), ethernet(1), isoethernet(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Autonegiotation package - aAutoNegLocalSectorAbility. (AutoNego)" ::= { sleAdvaGeneralEntry 17 } sleAdvaReceivedSectorAbility OBJECT-TYPE SYNTAX BITS { other(0), ethernet(1), isoethernet(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Autonegiotation package - aAutoNegLocalSectorAbility. (AutoNego)" ::= { sleAdvaGeneralEntry 18 } sleAdvaDuplexCapabilities OBJECT-TYPE SYNTAX INTEGER { halfduplex(0), fullduplex(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Mandatory package - aMacCapabilities. (PHY)The modes of duplex the access interface can support" ::= { sleAdvaGeneralEntry 19 } sleAdvaPHYType OBJECT-TYPE SYNTAX INTEGER { other(1), unknown(2), none(3), base10(4), base100T4(5), base100X(6), base100T2(7), base1000X(8), base1000T(9) } MAX-ACCESS read-only STATUS current DESCRIPTION "Basic Package - aPhyType. (PHY)" ::= { sleAdvaGeneralEntry 20 } sleAdvaPHYTypeList OBJECT-TYPE SYNTAX BITS { other(0), unknown(1), none(2), base10(3), base100T4(4), base100X(5), base100T2(6), base1000X(7), base1000T(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Basic Package - aPhyTypeList. (PHY)" ::= { sleAdvaGeneralEntry 21 } sleAdvaMIIDetect OBJECT-TYPE SYNTAX INTEGER { unknown(1), nothingConnected(2), connected(3), absent(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Basic Package - aMIIDetect. (PHY)" ::= { sleAdvaGeneralEntry 22 } sleAdvaPHYState OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleAdvaGeneralEntry 23 } sleAdvaGoodFramesTransmitted OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Mandatory package - aFramesTransmittedOK. (PHY)Non-resettable, wrapping count of good frames transmitted since OAM enabled." ::= { sleAdvaGeneralEntry 24 } sleAdvaSingleCollisionFrames OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Mandatory package - aSingleCollisionFrames. (PHY)Non-resettable, wrapping count of single collisions since OAM enabled." ::= { sleAdvaGeneralEntry 25 } sleAdvaMultipleCollisionFrames OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Mandatory package - aMultipleCollisionFrames. (PHY)Non-resettable, wrapping count of multiple collisions since OAM enabled." ::= { sleAdvaGeneralEntry 26 } sleAdvaGoodFramesReceived OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Mandatory package - aFramesReceivedOKNon-resettable, wrapping count of good frames received since OAM enabled" ::= { sleAdvaGeneralEntry 27 } sleAdvaFCSErrors OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Mandatory package - aFrameCheckSequenceErrors. (PHY)Non-resettable, wrapping count of frames received with frame check sequence error since OAM enabled." ::= { sleAdvaGeneralEntry 28 } sleAdvaAlignmentErrors OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Mandatory package - aAlignmentErrors. (PHY)Non-resettable, wrapping count of frames received with alignment error since OAM enabled." ::= { sleAdvaGeneralEntry 29 } sleAdvaFramesTooLong OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "aFrameTooLongErrors. (PHY)Non-resettable, wrapping count of frames received longer than maxFrameSize" ::= { sleAdvaGeneralEntry 30 } sleAdvaBytesTransmitted OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Non-resettable, wrapping count of bytes transmitted since OAM enabled. (PHY)" ::= { sleAdvaGeneralEntry 31 } sleAdvaBytesReceived OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Non-resettable, wrapping count of bytes received since OAM enabled. (PHY)" ::= { sleAdvaGeneralEntry 32 } sleAdvaSymbolErrors OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Non-resettable, wrapping count of symbol errors received. Note: some interfaces may only report one symbol error per frame. (PHY)" ::= { sleAdvaGeneralEntry 33 } sleAdvaGeneralControl OBJECT IDENTIFIER ::= { sleAdvaGeneral 2 } sleAdvaGeneralControlRequest OBJECT-TYPE SYNTAX INTEGER { setAdvaGeneralProfile(1), setAdvaAutonegProfile(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaGeneralControl 1 } sleAdvaGeneralControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleAdvaGeneralControl 2 } sleAdvaGeneralControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaGeneralControl 3 } sleAdvaGeneralControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaGeneralControl 4 } sleAdvaGeneralControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaGeneralControl 5 } sleAdvaGeneralControlPortIndex OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaGeneralControl 6 } sleAdvaGeneralControlRemInstance OBJECT-TYPE SYNTAX INTEGER (1..4) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaGeneralControl 7 } sleAdvaGeneralControlLineSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaGeneralControl 8 } sleAdvaGeneralControlAutonegiotation OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaGeneralControl 9 } sleAdvaGeneralControlLinkLossForwarding OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaGeneralControl 10 } sleAdvaGeneralControlUserDefinedString OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaGeneralControl 11 } sleAdvaGeneralControlAdvertisedTechnologyAbility OBJECT-TYPE SYNTAX BITS { global(0), unknown(1), base10T(2), base10TFD(3), base100T4(4), base100TX(5), base100TXFD(6), fdxpause(7), fdxapause(8), fdxspause(9), fdxbpause(10), base100T2(11), base100T2FD(12), base1000X(13), base1000XFD(14), base1000T(15), base1000TFD(16), remFault1(17), remFault2(18), isoEthernet(19) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaGeneralControl 12 } sleAdvaGeneralControlAdvertisedSectorAbility OBJECT-TYPE SYNTAX BITS { other(0), ethernet(1), isoethernet(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaGeneralControl 13 } sleAdvaGeneralNotification OBJECT IDENTIFIER ::= { sleAdvaGeneral 3 } sleAdvaGeneralProfileChanged NOTIFICATION-TYPE OBJECTS { sleAdvaGeneralControlRequest, sleAdvaGeneralControlReqResult, sleAdvaGeneralControlTimeStamp, sleAdvaLineSpeed, sleAdvaAutonegiotation, sleAdvaLinkLossForwarding, sleAdvaUserDefinedString } STATUS current DESCRIPTION "Description." ::= { sleAdvaGeneralNotification 1 } sleAdvaAutonegProfileChanged NOTIFICATION-TYPE OBJECTS { sleAdvaGeneralControlRequest, sleAdvaGeneralControlReqResult, sleAdvaGeneralControlTimeStamp, sleAdvaAdvertisedTechnologyAbility, sleAdvaAdvertisedSectorAbility } STATUS current DESCRIPTION "Description." ::= { sleAdvaGeneralNotification 2 } sleAdvaModule OBJECT IDENTIFIER ::= { sleFaultMgmt 8 } sleAdvaModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF SleAdvaModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleAdvaModule 1 } sleAdvaModuleEntry OBJECT-TYPE SYNTAX SleAdvaModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleOamPortIndex, sleAdvaRemInstance } ::= { sleAdvaModuleTable 1 } SleAdvaModuleEntry ::= SEQUENCE { sleAdvaModuleType INTEGER, sleAdvaModulePartNumber OCTET STRING, sleAdvaModuleSerialNumber OCTET STRING, sleAdvaModuleFirmwareVersion OCTET STRING, sleAdvaModuleSoftwareVersion OCTET STRING, sleAdvaModuleHardwareRevision OCTET STRING, sleAdvaModuleCLEICode OCTET STRING } sleAdvaModuleType OBJECT-TYPE SYNTAX INTEGER { sfp(1), nemi(2), other(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "encoding TBD" ::= { sleAdvaModuleEntry 1 } sleAdvaModulePartNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "Part number for the module" ::= { sleAdvaModuleEntry 2 } sleAdvaModuleSerialNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number for the module" ::= { sleAdvaModuleEntry 3 } sleAdvaModuleFirmwareVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "Firmware version for the module." ::= { sleAdvaModuleEntry 4 } sleAdvaModuleSoftwareVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "Software version for the module" ::= { sleAdvaModuleEntry 5 } sleAdvaModuleHardwareRevision OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..4)) MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware revision for the module." ::= { sleAdvaModuleEntry 6 } sleAdvaModuleCLEICode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..14)) MAX-ACCESS read-only STATUS current DESCRIPTION "CLEI for the module." ::= { sleAdvaModuleEntry 7 } sleAdvaOptical OBJECT IDENTIFIER ::= { sleFaultMgmt 9 } sleAdvaOpticalTable OBJECT-TYPE SYNTAX SEQUENCE OF SleAdvaOpticalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleAdvaOptical 1 } sleAdvaOpticalEntry OBJECT-TYPE SYNTAX SleAdvaOpticalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleOamPortIndex, sleAdvaRemInstance } ::= { sleAdvaOpticalTable 1 } SleAdvaOpticalEntry ::= SEQUENCE { sleAdvaOpticalThresholdLevel INTEGER, sleAdvaLinkLength1 INTEGER, sleAdvaLinkLength2 INTEGER, sleAdvaLinkLength3 INTEGER, sleAdvaLinkLength4 INTEGER, sleAdvaLinkLengthCu INTEGER, sleAdvaWaveLength INTEGER, sleAdvaLaserBias INTEGER, sleAdvaTransmitPower INTEGER, sleAdvaReceivePower INTEGER, sleAdvaLaserTxTemperature INTEGER } sleAdvaOpticalThresholdLevel OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Threshold for the receive power level in dBm below which the Interface optical threshold alarm will be activated.Per interface." ::= { sleAdvaOpticalEntry 1 } sleAdvaLinkLength1 OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Link length supported for 9/125 mm fiber, units of km" ::= { sleAdvaOpticalEntry 2 } sleAdvaLinkLength2 OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Link length supported for 9/125 mm fiber, units of 100 m" ::= { sleAdvaOpticalEntry 3 } sleAdvaLinkLength3 OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Link length supported for 50/125 mm fiber, units of 10 m" ::= { sleAdvaOpticalEntry 4 } sleAdvaLinkLength4 OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Link length supported for 62.5/125 mm fiber, units of 10 m" ::= { sleAdvaOpticalEntry 5 } sleAdvaLinkLengthCu OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Link length supported for copper, units of meters" ::= { sleAdvaOpticalEntry 6 } sleAdvaWaveLength OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Nominal wavelength in nm" ::= { sleAdvaOpticalEntry 7 } sleAdvaLaserBias OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Current laser bias current in mA." ::= { sleAdvaOpticalEntry 8 } sleAdvaTransmitPower OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Current transmit power in dBm as reported by optics." ::= { sleAdvaOpticalEntry 9 } sleAdvaReceivePower OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Current receive power in dBm as reported by optics. " ::= { sleAdvaOpticalEntry 10 } sleAdvaLaserTxTemperature OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Current temperature of laser in degrees C." ::= { sleAdvaOpticalEntry 11 } sleAdvaOpticalControl OBJECT IDENTIFIER ::= { sleAdvaOptical 2 } sleAdvaOpticalControlRequest OBJECT-TYPE SYNTAX INTEGER { setAdvaOpticalAlarm(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaOpticalControl 1 } sleAdvaOpticalControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleAdvaOpticalControl 2 } sleAdvaOpticalControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaOpticalControl 3 } sleAdvaOpticalControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaOpticalControl 4 } sleAdvaOpticalControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaOpticalControl 5 } sleAdvaOpticalControlPortIndex OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaOpticalControl 6 } sleAdvaOpticalControlRemInstance OBJECT-TYPE SYNTAX INTEGER (1..3) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaOpticalControl 7 } sleAdvaOpticalControlThresholdLevel OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaOpticalControl 8 } sleAdvaOpticalNotification OBJECT IDENTIFIER ::= { sleAdvaOptical 3 } sleAdvaOpticalAlarmChanged NOTIFICATION-TYPE OBJECTS { sleAdvaOpticalControlRequest, sleAdvaOpticalControlReqResult, sleAdvaOpticalControlTimeStamp, sleAdvaOpticalThresholdLevel } STATUS current DESCRIPTION "Description." ::= { sleAdvaOpticalNotification 1 } sleAdvaOam OBJECT IDENTIFIER ::= { sleFaultMgmt 10 } sleAdvaOamTable OBJECT-TYPE SYNTAX SEQUENCE OF SleAdvaOamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleAdvaOam 1 } sleAdvaOamEntry OBJECT-TYPE SYNTAX SleAdvaOamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleOamPortIndex, sleAdvaRemInstance } ::= { sleAdvaOamTable 1 } SleAdvaOamEntry ::= SEQUENCE { sleAdvaAdminStatus INTEGER, sleAdvaMode INTEGER, sleAdvaRemMACAddress OCTET STRING, sleAdvaRemConfig BITS, sleAdvaRemPduConfig INTEGER, sleAdvaLocFlags BITS, sleAdvaRemFlags BITS, sleAdvaRemState BITS, sleAdvaRemVendorOUI INTEGER, sleAdvaRemDeviceNumber INTEGER, sleAdvaRemVendorVersion INTEGER, sleAdvaLocErrSymbolPeriodEventConfig INTEGER, sleAdvaLocErrFrameEventConfig INTEGER, sleAdvaLocErrFramePeriodEventConfig INTEGER, sleAdvaLocErrFrameSecsSummaryEventConfig INTEGER, sleAdvaPDUsTx Integer32, sleAdvaPDUsRx Integer32, sleAdvaUnsupportedCodesRx Integer32, sleAdvaInfoPDUsTx Integer32, sleAdvaInfoPDUsRx Integer32, sleAdvaEventNotificationPDUsTx Integer32, sleAdvaUniqueEventNotificationPDUsTx Integer32, sleAdvaDupEventNotificationPDUsTx Integer32, sleAdvaLoopbackControlPDUsTx Integer32, sleAdvaLoopbackControlPDUsRx Integer32, sleAdvaVariableRequestPDUsTx Integer32, sleAdvaVariableRequestPDUsRx Integer32, sleAdvaVariableResponsePDUsTx Integer32, sleAdvaVariableResponsePDUsRx Integer32, sleAdvaVendorPDUsTx Integer32, sleAdvaVendorPDUsRx Integer32, sleAdvaRemFramesLostDuetoOAMErr Integer32, sleAdvaLocErrSymbolPeriodEvent Integer32, sleAdvaLocErrFrameSecsEvent Integer32, sleAdvaLocErrFramePeriodEvent Integer32, sleAdvaLocErrFrameSecsSummaryEvent Integer32, sleAdvaRemErrSymbolPeriodEvent Integer32, sleAdvaRemErrFrameSecsEvent Integer32, sleAdvaRemoteErrorFramePeriodEvent Integer32, sleAdvaRemoteErrorFrameSecsSummaryEvent Integer32 } sleAdvaAdminStatus OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMAdminState (Configuration)Whether the OAM sublayer is enabled or disabled." ::= { sleAdvaOamEntry 1 } sleAdvaMode OBJECT-TYPE SYNTAX INTEGER { passive(0), active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMMode. (Configuration)Mode of the OAM client" ::= { sleAdvaOamEntry 2 } sleAdvaRemMACAddress OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMRemoteMACAddress. (Configuration)" ::= { sleAdvaOamEntry 3 } sleAdvaRemConfig OBJECT-TYPE SYNTAX BITS { unidirSupport(0), loopbackSupport(1), linkEvents(2), variableRetrieval(3), orgSpecific(4), orgSpecificEvents(5), orgSpecificInfoTLV(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMRemoteConfiguration. (Configuration)Bit-mask corresponding to the OAM configuration field:" ::= { sleAdvaOamEntry 4 } sleAdvaRemPduConfig OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMRemotePDUConfiguration. (Configuration)The maximum PDU size supported" ::= { sleAdvaOamEntry 5 } sleAdvaLocFlags OBJECT-TYPE SYNTAX BITS { linkFault(0), dyingGasp(1), criticalEvent(2), localStableDiscovering(3), localStable(4), remoteStableDiscovering(5), remoteStable(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMLocalFlags. (Configuration)Bit-mask corresponding to the OAM flag field transmitted:" ::= { sleAdvaOamEntry 6 } sleAdvaRemFlags OBJECT-TYPE SYNTAX BITS { linkFault(0), dyingGasp(1), criticalEvent(2), localStableDiscovering(3), localStable(4), remoteStableDiscovering(5), remoteStable(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMRemoteFlags. (Configuration)Bit-mask corresponding to the OAM flag field received" ::= { sleAdvaOamEntry 7 } sleAdvaRemState OBJECT-TYPE SYNTAX BITS { reserved(0), parserAction1(1), parserAction2(2), muxAction(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMRemoteState. (Configuration)Bit-mask corresponding to the OAM State field received" ::= { sleAdvaOamEntry 8 } sleAdvaRemVendorOUI OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMRemoteVendorOUI. (Configuration)The value of the OUI from the remote end of the OAM link." ::= { sleAdvaOamEntry 9 } sleAdvaRemDeviceNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMRemoteVendorIdDeviceNumber. (Configuration) The value of the Device Identifier from the remote end of the OAM link." ::= { sleAdvaOamEntry 10 } sleAdvaRemVendorVersion OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMRemoteVendorIdVersion. (Configuration) The value of the Version Identifier from the remote end of the OAM link." ::= { sleAdvaOamEntry 11 } sleAdvaLocErrSymbolPeriodEventConfig OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMLocalErrSymPeriodConfig. (Configuration) Configuration for the event indicating the duration of the period and the number of symbols that must be exceeded." ::= { sleAdvaOamEntry 12 } sleAdvaLocErrFrameEventConfig OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMLocalErrFrameConfig. (Configuration) Configuration for the event indicating the duration and the number of errored frames that must be exceeded." ::= { sleAdvaOamEntry 13 } sleAdvaLocErrFramePeriodEventConfig OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMLocalErrFramePeriodConfig. (Configuration) Configuration for the event indicating the durationin terms of minFrameSize that can be transmitted and that number of errored frames that must be exceeded." ::= { sleAdvaOamEntry 14 } sleAdvaLocErrFrameSecsSummaryEventConfig OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMLocalErrFrameSecsSummaryConfig. (Configuration) Configuration for the evert indicating duration window and number of errored frame seconds in that duration that must be exceeded." ::= { sleAdvaOamEntry 15 } sleAdvaPDUsTx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMPDUTx. (PDU Performance)Non-resettable, wrapping count of OAM PDUs transmitted since OAM enabled." ::= { sleAdvaOamEntry 16 } sleAdvaPDUsRx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMPDURx. (PDU Performance)Non-resettable, wrapping count of OAM PDUs received since OAM enabled." ::= { sleAdvaOamEntry 17 } sleAdvaUnsupportedCodesRx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMUnsupportedCodesRx. (PDU Performance)Non-resettable, wrapping count of OAM PDUs received that are not supported by device since OAM enabled." ::= { sleAdvaOamEntry 18 } sleAdvaInfoPDUsTx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMInformationTx. (PDU Performance)Non-resettable, wrapping count of OAM Info PDUs transmitted since OAM enabled." ::= { sleAdvaOamEntry 19 } sleAdvaInfoPDUsRx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMInformationRx. (PDU Performance)Non-resettable, wrapping count of OAM Info PDUs received since OAM enabled." ::= { sleAdvaOamEntry 20 } sleAdvaEventNotificationPDUsTx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMEventNotificationTx. (PDU Performance)Non-resettable, wrapping count of OAM Event PDUs transmitted since OAM enabled." ::= { sleAdvaOamEntry 21 } sleAdvaUniqueEventNotificationPDUsTx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMUniqueEventNotificationTx. (PDU Performance) Non-resettable, wrapping count of OAM Event PDUs received with a different sequence number than previously since OAM enabled." ::= { sleAdvaOamEntry 22 } sleAdvaDupEventNotificationPDUsTx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMDuplicateEventNotificationTx. (PDU Performance) Non-resettable, wrapping count of OAM Event PDUs received with the same sequence number as previously since OAM enabled." ::= { sleAdvaOamEntry 23 } sleAdvaLoopbackControlPDUsTx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMLoopbackControlTx. (PDU Performance) Non-resettable, wrapping count of OAM Loopback Control PDUs transmitted since OAM enabled." ::= { sleAdvaOamEntry 24 } sleAdvaLoopbackControlPDUsRx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMLoopbackControlRx. (PDU Performance) Non-resettable, wrapping count of OAM Loopback Control PDUs received since OAM enabled." ::= { sleAdvaOamEntry 25 } sleAdvaVariableRequestPDUsTx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMVariableRequestTx. (PDU Performance) Non-resettable, wrapping count of OAM Variable Request PDUs transmitted since OAM enabled." ::= { sleAdvaOamEntry 26 } sleAdvaVariableRequestPDUsRx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMVariableRequestRx. (PDU Performance) Non-resettable, wrapping count of OAM Variable Request PDUs received since OAM enabled." ::= { sleAdvaOamEntry 27 } sleAdvaVariableResponsePDUsTx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMVariableResponseTx. (PDU Performance) Non-resettable, wrapping count of OAM Variable Response PDUs transmitted since OAM enabled." ::= { sleAdvaOamEntry 28 } sleAdvaVariableResponsePDUsRx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMVariableResponseRx. (PDU Performance) Non-resettable, wrapping count of OAM Variable Response PDUs received since OAM enabled" ::= { sleAdvaOamEntry 29 } sleAdvaVendorPDUsTx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMOrganizationSpecificTx . (PDU Performance) Non-resettable, wrapping count of OAM Vendor PDUs transmitted since OAM enabled." ::= { sleAdvaOamEntry 30 } sleAdvaVendorPDUsRx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aOAMOrganizationSpecificRx. (PDU Performance)" ::= { sleAdvaOamEntry 31 } sleAdvaRemFramesLostDuetoOAMErr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "OAM package - aFramesLostDueToOAMError. (PDU Performance) Non-resettable, wrapping count of frames that would have been transmitted but for an OAM sublayer error." ::= { sleAdvaOamEntry 32 } sleAdvaLocErrSymbolPeriodEvent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The most recently transmitted event of this type. (Error)" ::= { sleAdvaOamEntry 33 } sleAdvaLocErrFrameSecsEvent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The most recently transmitted event of this type. (Error)" ::= { sleAdvaOamEntry 34 } sleAdvaLocErrFramePeriodEvent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The most recently transmitted event of this type. (Error)" ::= { sleAdvaOamEntry 35 } sleAdvaLocErrFrameSecsSummaryEvent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The most recently transmitted event of this type. (Error)" ::= { sleAdvaOamEntry 36 } sleAdvaRemErrSymbolPeriodEvent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The most recently received event of this type. (Error)" ::= { sleAdvaOamEntry 37 } sleAdvaRemErrFrameSecsEvent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The most recently received event of this type. (Error)" ::= { sleAdvaOamEntry 38 } sleAdvaRemoteErrorFramePeriodEvent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The most recently received event of this type. (Error)" ::= { sleAdvaOamEntry 39 } sleAdvaRemoteErrorFrameSecsSummaryEvent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The most recently received event of this type. (Error)" ::= { sleAdvaOamEntry 40 } sleAdvaOamControl OBJECT IDENTIFIER ::= { sleAdvaOam 2 } sleAdvaOamControlRequest OBJECT-TYPE SYNTAX INTEGER { setAdvaOamProfile(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaOamControl 1 } sleAdvaOamControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleAdvaOamControl 2 } sleAdvaOamControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaOamControl 3 } sleAdvaOamControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaOamControl 4 } sleAdvaOamControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaOamControl 5 } sleAdvaOamControlPortIndex OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaOamControl 6 } sleAdvaOamControlRemInstance OBJECT-TYPE SYNTAX INTEGER (1..2) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaOamControl 7 } sleAdvaOamControlAdminStatus OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaOamControl 8 } sleAdvaOamControlMode OBJECT-TYPE SYNTAX INTEGER { passive(0), active(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAdvaOamControl 9 } sleAdvaOamNotification OBJECT IDENTIFIER ::= { sleAdvaOam 3 } setAdvaOamProfileChanged NOTIFICATION-TYPE OBJECTS { sleAdvaOamControlRequest, sleAdvaOamControlReqResult, sleAdvaOamControlTimeStamp, sleAdvaAdminStatus, sleAdvaMode } STATUS current DESCRIPTION "Description." ::= { sleAdvaOamNotification 1 } sleAlarmLED OBJECT IDENTIFIER ::= { sleFaultMgmt 11 } sleAlarmLEDTable OBJECT-TYPE SYNTAX SEQUENCE OF SleAlarmLEDEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleAlarmLED 1 } sleAlarmLEDEntry OBJECT-TYPE SYNTAX SleAlarmLEDEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleAlarmLEDType } ::= { sleAlarmLEDTable 1 } SleAlarmLEDEntry ::= SEQUENCE { sleAlarmLEDType INTEGER, sleAlarmLEDStatus INTEGER, sleAlarmLEDLevel INTEGER } sleAlarmLEDType OBJECT-TYPE SYNTAX INTEGER { fanFail(1), fanRemove(2), memoryOver(3), moduleRemove(4), portLinkDown(5), portRemove(6), portThreadOver(7), powerFail(8), powerRemove(9), temperatureHigh(10), slotRemove(11), ponLOS(12) } MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm that LED indicate." ::= { sleAlarmLEDEntry 1 } sleAlarmLEDStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), unknown(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of alarm LED." ::= { sleAlarmLEDEntry 2 } sleAlarmLEDLevel OBJECT-TYPE SYNTAX INTEGER { critical(1), major(2), minor(3), unrated(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Level of alarm LED." ::= { sleAlarmLEDEntry 3 } sleAlarmLEDLevelTable OBJECT-TYPE SYNTAX SEQUENCE OF SleAlarmLEDLevelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleAlarmLED 2 } sleAlarmLEDLevelEntry OBJECT-TYPE SYNTAX SleAlarmLEDLevelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleAlarmLEDLevelIndex } ::= { sleAlarmLEDLevelTable 1 } SleAlarmLEDLevelEntry ::= SEQUENCE { sleAlarmLEDLevelIndex INTEGER, sleAlarmLEDLevelBlock INTEGER, sleAlarmLEDLevelOperStatus INTEGER } sleAlarmLEDLevelIndex OBJECT-TYPE SYNTAX INTEGER { critical(1), major(2), minor(3), error(4), unrated(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "LED level index." ::= { sleAlarmLEDLevelEntry 1 } sleAlarmLEDLevelBlock OBJECT-TYPE SYNTAX INTEGER { unblock(1), block(2), unknown(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "LED level block." ::= { sleAlarmLEDLevelEntry 2 } sleAlarmLEDLevelOperStatus OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm current operation status." ::= { sleAlarmLEDLevelEntry 3 } sleAlarmLEDControl OBJECT IDENTIFIER ::= { sleAlarmLED 3 } sleAlarmLEDControlRequest OBJECT-TYPE SYNTAX INTEGER { alarmLedOff(1), setAlarmLedLevel(2), clearAlarmLed(3), alarmLedBlock(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAlarmLEDControl 1 } sleAlarmLEDControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleAlarmLEDControl 2 } sleAlarmLEDControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleAlarmLEDControl 3 } sleAlarmLEDControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleAlarmLEDControl 4 } sleAlarmLEDControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleAlarmLEDControl 5 } sleAlarmLEDControlType OBJECT-TYPE SYNTAX INTEGER { fanFail(1), fanRemove(2), memoryOver(3), moduleRemove(4), portLinkDown(5), portRemove(6), portThreadOver(7), powerFail(8), powerRemove(9), temperatureHigh(10), slotRemove(11), ponLOS(12) } MAX-ACCESS read-write STATUS current DESCRIPTION "The alarm that LED indicate." ::= { sleAlarmLEDControl 6 } sleAlarmLEDControlLevel OBJECT-TYPE SYNTAX INTEGER { critical(1), major(2), minor(3), all(254) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Level of alarm LED." ::= { sleAlarmLEDControl 7 } sleAlarmLEDControlBlock OBJECT-TYPE SYNTAX INTEGER { unblock(1), block(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "LED level block." ::= { sleAlarmLEDControl 8 } sleAlarmLEDNotification OBJECT IDENTIFIER ::= { sleAlarmLED 4 } sleAlarmLEDOffChanged NOTIFICATION-TYPE OBJECTS { sleAlarmLEDControlRequest, sleAlarmLEDControlTimeStamp, sleAlarmLEDControlReqResult, sleAlarmLEDControlLevel } STATUS current DESCRIPTION "Description." ::= { sleAlarmLEDNotification 1 } sleAlarmLEDLevelChanged NOTIFICATION-TYPE OBJECTS { sleAlarmLEDControlRequest, sleAlarmLEDControlTimeStamp, sleAlarmLEDControlReqResult, sleAlarmLEDControlType, sleAlarmLEDControlLevel } STATUS current DESCRIPTION "Description." ::= { sleAlarmLEDNotification 2 } sleAlarmLEDCleared NOTIFICATION-TYPE OBJECTS { sleAlarmLEDControlRequest, sleAlarmLEDControlTimeStamp, sleAlarmLEDControlReqResult, sleAlarmLEDControlType } STATUS current DESCRIPTION "Description." ::= { sleAlarmLEDNotification 3 } sleAlarmLEDBlockChanged NOTIFICATION-TYPE OBJECTS { sleAlarmLEDControlRequest, sleAlarmLEDControlTimeStamp, sleAlarmLEDControlReqResult, sleAlarmLEDControlLevel, sleAlarmLEDControlBlock } STATUS current DESCRIPTION "Description." ::= { sleAlarmLEDNotification 4 } sleY1731Oam OBJECT IDENTIFIER ::= { sleFaultMgmt 12 } sleY1731Base OBJECT IDENTIFIER ::= { sleY1731Oam 1 } sleY1731BaseGroup OBJECT IDENTIFIER ::= { sleY1731Base 1 } sleY1731Enable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables/Ddisables ITU-T Y.1731 OAM function" ::= { sleY1731BaseGroup 1 } sleY1731TrunkEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables/Disables Y.1731 OAM on a trunk port" ::= { sleY1731BaseGroup 2 } sleY1731LtrCacheHoldTime OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the time that cache entries will be retained" ::= { sleY1731BaseGroup 3 } sleY1731LtrCacheSize OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of entries in the traceroute cache" ::= { sleY1731BaseGroup 4 } sleY1731SnmpServerTraps OBJECT-TYPE SYNTAX BITS { rdi(0), loc(1), unp(2), unm(3), mmg(4), unl(5), ais(6), lck(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the SNMP traps" ::= { sleY1731BaseGroup 5 } sleY1731XcheckStartDelay OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the delay before the cross-check is started" ::= { sleY1731BaseGroup 6 } sleY1731DefaultMegLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level to be created dynamic MHF" ::= { sleY1731BaseGroup 7 } sleY1731DefaultMegMhfCreation OBJECT-TYPE SYNTAX INTEGER { none(0), default(1), explicit(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the mode of MHF creation" ::= { sleY1731BaseGroup 8 } sleY1731PduToCfm OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables/Disables changing from Y.1731 PDU format to CFM PDU format" ::= { sleY1731BaseGroup 9 } sleY1731DedicatedVlan OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731BaseGroup 10 } sleY1731RmepCreation OBJECT-TYPE SYNTAX INTEGER { dynamic(1), static(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "RMEP creation mode" ::= { sleY1731BaseGroup 11 } sleY1731CCIgnoreDefect OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "CC Ignore Defect Mode" ::= { sleY1731BaseGroup 12 } sleY1731RapsFloodingBlock OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "R-APS Flooding Block Mode" ::= { sleY1731BaseGroup 13 } sleY1731TlvPermission OBJECT-TYPE SYNTAX INTEGER { none(1), chassis(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates TLV Permission" ::= { sleY1731BaseGroup 14 } sleY1731BaseControl OBJECT IDENTIFIER ::= { sleY1731Base 2 } sleY1731BaseControlRequest OBJECT-TYPE SYNTAX INTEGER { setY1731Enable(1), setY1731TrunkEnable(2), setY1731LtrCacheProfile(3), setY1731SnmpProfile(4), setY1731XcheckProfile(5), setY1731DefaultMegProfile(6), setY1731PduToCfm(7), setY1731DedicatedVlan(8), destroyMipCcdb(9), destroyLtrCache(10), setRmepCreation(11), setTrunkOamstatus(12), setY1731CCIgnoreDefect(13), setY1731RapsFloodingBlock(14), setY1731TlvPermission(15) } MAX-ACCESS read-write STATUS current DESCRIPTION " This attribute identifies the control commands. updateAlarmList: the NE updates entries of alarms in the sleAlarmListTable after having changed alarm severities of alarms (due to change profile pointers in managed entities or after modification of alarm severities in profiles). This command should be applied once after having finisled modifications of severties. modifyAlarmSeverity: modifies the severity of an alarm in specific profile. createAlarmSeverityProfile: creates a new profile with default severities. The severities then have to be modified with command changeAlarmSeverity. deleteAlarmSeverityProfile: deletes a profile. Profile 1 is not allowed to be deleted. Notifications : none " ::= { sleY1731BaseControl 1 } sleY1731BaseControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION " The status of a control request. " ::= { sleY1731BaseControl 2 } sleY1731BaseControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION " The maximum wait time for the manager for command ending. For long running commands. The manager reads this value from the DSLAM. " ::= { sleY1731BaseControl 3 } sleY1731BaseControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION " The time stamp of the last command (end of command). " ::= { sleY1731BaseControl 4 } sleY1731BaseControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION " The result of the last user command. " ::= { sleY1731BaseControl 5 } sleY1731BaseControlEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Ddisables ITU-T Y.1731 OAM function" ::= { sleY1731BaseControl 6 } sleY1731BaseControlTrunkEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables Y.1731 OAM on a trunk port" ::= { sleY1731BaseControl 7 } sleY1731BaseControlLtrCacheHoldTime OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the time that cache entries will be retained" ::= { sleY1731BaseControl 8 } sleY1731BaseControlLtrCacheSize OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the number of entries in the traceroute cache" ::= { sleY1731BaseControl 9 } sleY1731BaseControlSnmpServerTraps OBJECT-TYPE SYNTAX BITS { rdi(0), loc(1), unp(2), unm(3), mmg(4), unl(5), ais(6), lck(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the SNMP traps" ::= { sleY1731BaseControl 10 } sleY1731BaseControlXcheckStartDelay OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the delay before the cross-check is started" ::= { sleY1731BaseControl 11 } sleY1731BaseControlDefaultMegLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the level to be created dynamic MHF" ::= { sleY1731BaseControl 12 } sleY1731BaseControlDefaultMegMhfCreation OBJECT-TYPE SYNTAX INTEGER { none(0), default(1), explicit(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the mode of MHF creation" ::= { sleY1731BaseControl 13 } sleY1731BaseControlPduToCfm OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731BaseControl 14 } sleY1731BaseControlDedicatedVlan OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731BaseControl 15 } sleY1731BaseControlRmepCreation OBJECT-TYPE SYNTAX INTEGER { dynamic(1), static(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "RMEP creation mode" ::= { sleY1731BaseControl 16 } sleY1731BaseControlTrunkIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Trunk Index" ::= { sleY1731BaseControl 17 } sleY1731BaseControlTrunkOamStatus OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "OAM status per each Trunk port." ::= { sleY1731BaseControl 18 } sleY1731BaseControlTrunkMeg OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "trunk port meg name." ::= { sleY1731BaseControl 19 } sleY1731BaseControlCCIgnoreDefect OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "CC Ignore Defect Mode" ::= { sleY1731BaseControl 20 } sleY1731BaseControlRapsFloodingBlock OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "R-APS Flooding Block Mode" ::= { sleY1731BaseControl 21 } sleY1731BaseControlTlvPermission OBJECT-TYPE SYNTAX INTEGER { none(1), chassis(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates TLV Permission" ::= { sleY1731BaseControl 22 } sleY1731BaseNotification OBJECT IDENTIFIER ::= { sleY1731Base 3 } sleY1731EnableChanged NOTIFICATION-TYPE OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlEnable } STATUS current DESCRIPTION "setY1731Enable" ::= { sleY1731BaseNotification 1 } sleY1731TrunkEnableChanged NOTIFICATION-TYPE OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlTrunkEnable } STATUS current DESCRIPTION "setY1731TrunkEnable" ::= { sleY1731BaseNotification 2 } sleY1731LtrCacheProfileChanged NOTIFICATION-TYPE OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlLtrCacheHoldTime, sleY1731BaseControlLtrCacheSize } STATUS current DESCRIPTION "setY1731LtrCacheProfile" ::= { sleY1731BaseNotification 3 } sleY1731SnmpProfileChanged NOTIFICATION-TYPE OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlSnmpServerTraps } STATUS current DESCRIPTION "setY1731SnmpProfile" ::= { sleY1731BaseNotification 4 } sleY1731XcheckProfileChanged NOTIFICATION-TYPE OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlXcheckStartDelay } STATUS current DESCRIPTION "setY1731XcheckProfile" ::= { sleY1731BaseNotification 5 } sleY1731DefaultMegProfileChanged NOTIFICATION-TYPE OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlDefaultMegLevel, sleY1731BaseControlDefaultMegMhfCreation } STATUS current DESCRIPTION "setY1731DefaultMegProfile" ::= { sleY1731BaseNotification 6 } sleY1731PduToCfmChanged NOTIFICATION-TYPE OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlPduToCfm } STATUS current DESCRIPTION "Description." ::= { sleY1731BaseNotification 7 } sleY1731DedicatedVlanChanged NOTIFICATION-TYPE OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlDedicatedVlan } STATUS current DESCRIPTION "Description." ::= { sleY1731BaseNotification 8 } sleY1731MipCcdbDestroyed NOTIFICATION-TYPE OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult } STATUS current DESCRIPTION "destroyMipCcdb" ::= { sleY1731BaseNotification 9 } sleY1731LtrCacheDestroyed NOTIFICATION-TYPE OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult } STATUS current DESCRIPTION "destroyLtrCache" ::= { sleY1731BaseNotification 10 } sleY1731RmepCreationChanged NOTIFICATION-TYPE OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlRmepCreation } STATUS current DESCRIPTION "sleY1731BaseControlRmepCreation" ::= { sleY1731BaseNotification 11 } sleY1731TrunkOamStatusChanged NOTIFICATION-TYPE OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlTrunkIndex, sleY1731BaseControlTrunkOamStatus, sleY1731BaseControlTrunkMeg } STATUS current DESCRIPTION "sleY1731BaseControlTrunkIndex sleY1731BaseControlTrunkOamStatus" ::= { sleY1731BaseNotification 12 } sleY1731CCIgnoreDefectChanged NOTIFICATION-TYPE OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlCCIgnoreDefect } STATUS current DESCRIPTION "sleY1731BaseControlCCIgnoreDefect" ::= { sleY1731BaseNotification 13 } sleY1731RapsFloodinBlockChanged NOTIFICATION-TYPE OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlRapsFloodingBlock } STATUS current DESCRIPTION "sleY1731BaseControlCCIgnoreDefect" ::= { sleY1731BaseNotification 14 } sleY1731TlvPermissionChanged NOTIFICATION-TYPE OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlTlvPermission } STATUS current DESCRIPTION "setY1731TlvPermission" ::= { sleY1731BaseNotification 15 } sleY1731TrunkTable OBJECT-TYPE SYNTAX SEQUENCE OF SleY1731TrunkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleY1731Base 4 } sleY1731TrunkEntry OBJECT-TYPE SYNTAX SleY1731TrunkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleY1731TrunkIndex } ::= { sleY1731TrunkTable 1 } SleY1731TrunkEntry ::= SEQUENCE { sleY1731TrunkIndex INTEGER, sleY1731TrunkOamStatus INTEGER, sleY1731TrunkMeg OCTET STRING } sleY1731TrunkIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "trunk port index." ::= { sleY1731TrunkEntry 1 } sleY1731TrunkOamStatus OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "OAM status per each Trunk port." ::= { sleY1731TrunkEntry 2 } sleY1731TrunkMeg OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "trunk port meg name." ::= { sleY1731TrunkEntry 3 } sleY1731Meg OBJECT IDENTIFIER ::= { sleY1731Oam 2 } sleY1731MegTable OBJECT-TYPE SYNTAX SEQUENCE OF SleY1731MegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleY1731Meg 1 } sleY1731MegEntry OBJECT-TYPE SYNTAX SleY1731MegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleY1731MegIndex } ::= { sleY1731MegTable 1 } SleY1731MegEntry ::= SEQUENCE { sleY1731MegIndex Integer32, sleY1731MegName OCTET STRING, sleY1731MegLevel Integer32, sleY1731MegVid Integer32, sleY1731MegMepEnable INTEGER, sleY1731MegCcEnable INTEGER, sleY1731MegCcInterval Integer32, sleY1731MegCcPriority Integer32, sleY1731MegCcLossThreshold Integer32, sleY1731MegCcHoldTime Integer32, sleY1731MegFaultPriority Integer32, sleY1731MegFaultKeepTime Integer32, sleY1731MegFaultClearTime Integer32, sleY1731MegXcheckEnable INTEGER, sleY1731MegAisEnable INTEGER, sleY1731MegAisTransmitEnable INTEGER, sleY1731MegAisInterval INTEGER, sleY1731MegAisLevel Integer32, sleY1731MegAisPriority Integer32, sleY1731MegLckEnable INTEGER, sleY1731MegLckTransmitEnable INTEGER, sleY1731MegLckInterval INTEGER, sleY1731MegLckLevel Integer32, sleY1731MegLckPriority Integer32, sleY1731MegOutOfService INTEGER, sleY1731MegRapsEnable INTEGER, sleY1731MegRapsRplOwner INTEGER, sleY1731MegRapsEastPort Integer32, sleY1731MegRapsWestPort Integer32, sleY1731MegRapsRplPort INTEGER, sleY1731MegRapsHoldOffTime Integer32, sleY1731MegRapsGuardTime Integer32, sleY1731MegRapsWaitToRestore Integer32, sleY1731MegRapsState INTEGER, sleY1731MegRapsEastPortStatus INTEGER, sleY1731MegRapsWestPortStatus INTEGER, sleY1731MegRapsNonRevertive INTEGER, sleY1731MegRapsForcedSwitchEast INTEGER, sleY1731MegRapsForcedSwitchWest INTEGER, sleY1731MegMd OCTET STRING } sleY1731MegIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the MEG's Index" ::= { sleY1731MegEntry 1 } sleY1731MegName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..12)) MAX-ACCESS read-only STATUS current DESCRIPTION "The MEG's name: ICC (6 bytes) + UMC (6 bytes)" ::= { sleY1731MegEntry 2 } sleY1731MegLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the MEG's level" ::= { sleY1731MegEntry 3 } sleY1731MegVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the MEG's VID" ::= { sleY1731MegEntry 4 } sleY1731MegMepEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables/Disables Y.1731 OAM for MEPs" ::= { sleY1731MegEntry 5 } sleY1731MegCcEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables/Disables MEPs to send Continuity Check messages" ::= { sleY1731MegEntry 6 } sleY1731MegCcInterval OBJECT-TYPE SYNTAX Integer32 (1 | 2..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the interval between CCM transmissions" ::= { sleY1731MegEntry 7 } sleY1731MegCcPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the CCM or LTM Message Priority" ::= { sleY1731MegEntry 8 } sleY1731MegCcLossThreshold OBJECT-TYPE SYNTAX Integer32 (2..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the minimum number of CCMs that can be missed before declaring that a MEP is down" ::= { sleY1731MegEntry 9 } sleY1731MegCcHoldTime OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the time that data of a missing MEP is kept" ::= { sleY1731MegEntry 10 } sleY1731MegFaultPriority OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the lowest priority for fault alarm" ::= { sleY1731MegEntry 11 } sleY1731MegFaultKeepTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the keep time for the fault alarm" ::= { sleY1731MegEntry 12 } sleY1731MegFaultClearTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the clear time for the fault alarm" ::= { sleY1731MegEntry 13 } sleY1731MegXcheckEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables/Disables Y.1731 cross-check for a specific MEG" ::= { sleY1731MegEntry 14 } sleY1731MegAisEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables/Disables ETH-AIS function" ::= { sleY1731MegEntry 15 } sleY1731MegAisTransmitEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables/Disables ETH-AIS frame transmission on a MEP" ::= { sleY1731MegEntry 16 } sleY1731MegAisInterval OBJECT-TYPE SYNTAX INTEGER { oneSecond(4), oneMinute(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the interval between AIS transmissions" ::= { sleY1731MegEntry 17 } sleY1731MegAisLevel OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the client MEG's level" ::= { sleY1731MegEntry 18 } sleY1731MegAisPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the AIS Message Priority" ::= { sleY1731MegEntry 19 } sleY1731MegLckEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables/Disables ETH-LCK function" ::= { sleY1731MegEntry 20 } sleY1731MegLckTransmitEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables/Disables ETH-LCK frame transmission on a MEP" ::= { sleY1731MegEntry 21 } sleY1731MegLckInterval OBJECT-TYPE SYNTAX INTEGER { oneSecond(4), oneMinute(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the interval between LCK transmissions" ::= { sleY1731MegEntry 22 } sleY1731MegLckLevel OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the client MEG's level" ::= { sleY1731MegEntry 23 } sleY1731MegLckPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the LCK Message Priority" ::= { sleY1731MegEntry 24 } sleY1731MegOutOfService OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the out-of-service mode" ::= { sleY1731MegEntry 25 } sleY1731MegRapsEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables/Disables R-APS node" ::= { sleY1731MegEntry 26 } sleY1731MegRapsRplOwner OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the owner of the ring protection link" ::= { sleY1731MegEntry 27 } sleY1731MegRapsEastPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the east port of R-APS node" ::= { sleY1731MegEntry 28 } sleY1731MegRapsWestPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the west port of R-APS node" ::= { sleY1731MegEntry 29 } sleY1731MegRapsRplPort OBJECT-TYPE SYNTAX INTEGER { none(-1), east(0), west(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the RPL port of R-APS node" ::= { sleY1731MegEntry 30 } sleY1731MegRapsHoldOffTime OBJECT-TYPE SYNTAX Integer32 (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the hold-off time for verifying local SF" ::= { sleY1731MegEntry 31 } sleY1731MegRapsGuardTime OBJECT-TYPE SYNTAX Integer32 (10..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the guard time for verifying local clear SF" ::= { sleY1731MegEntry 32 } sleY1731MegRapsWaitToRestore OBJECT-TYPE SYNTAX Integer32 (5..720) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the wait-to-restore time for verifying remote SF" ::= { sleY1731MegEntry 33 } sleY1731MegRapsState OBJECT-TYPE SYNTAX INTEGER { none(0), idle(1), protection(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate the state of r-aps state machine" ::= { sleY1731MegEntry 34 } sleY1731MegRapsEastPortStatus OBJECT-TYPE SYNTAX INTEGER { none(0), disabled(1), forwarding(2), blocking(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The port status of east port." ::= { sleY1731MegEntry 35 } sleY1731MegRapsWestPortStatus OBJECT-TYPE SYNTAX INTEGER { none(0), disabled(1), forwarding(2), blocking(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The port status of west port." ::= { sleY1731MegEntry 36 } sleY1731MegRapsNonRevertive OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "NonRevertive" ::= { sleY1731MegEntry 37 } sleY1731MegRapsForcedSwitchEast OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "ForcedSwitchEast" ::= { sleY1731MegEntry 38 } sleY1731MegRapsForcedSwitchWest OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "ForcedSwitchWest" ::= { sleY1731MegEntry 39 } sleY1731MegMd OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..12)) MAX-ACCESS read-only STATUS current DESCRIPTION "The MD name of MEG." ::= { sleY1731MegEntry 40 } sleY1731MegControl OBJECT IDENTIFIER ::= { sleY1731Meg 2 } sleY1731MegControlRequest OBJECT-TYPE SYNTAX INTEGER { createY1731Meg(1), deleteY1731Meg(2), setY1731MegMepEnable(3), setY1731MegCcEnable(4), setY1731MegCcProfile(5), setY1731MegFaultProfile(6), setY1731MegXcheckEnable(7), setY1731MegAisEnable(8), setY1731MegAisTransmitEnable(9), setY1731MegAisProfile(10), setY1731MegLckEnable(11), setY1731MegLckTransmitEnable(12), setY1731MegLckProfile(13), setY1731MegOutOfService(14), setY1731MegRapsEnable(15), setY1731MegRapsRingports(16), setY1731MegRapsRplPort(17), setY1731MegRapsRplOwner(18), setY1731MegRapsRplTimer(19), destroyY1731MegRemoteMep(20), destroyY1731MegError(21), setY1731MegRapsNonRevertive(22), setY1731MegRapsForcedSwitchEast(23), setY1731MegRapsForcedSwitchWest(24), addY1731MegMd(25), delY1731MegMd(26) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731MegControl 1 } sleY1731MegControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731MegControl 2 } sleY1731MegControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731MegControl 3 } sleY1731MegControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731MegControl 4 } sleY1731MegControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731MegControl 5 } sleY1731MegControlIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the MEG's Index" ::= { sleY1731MegControl 6 } sleY1731MegControlName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "The MEG's name: ICC (6 bytes) + UMC (6 bytes)" ::= { sleY1731MegControl 7 } sleY1731MegControlLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the MEG's level" ::= { sleY1731MegControl 8 } sleY1731MegControlVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the MEG's VID" ::= { sleY1731MegControl 9 } sleY1731MegControlMepEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables Y.1731 OAM for MEPs" ::= { sleY1731MegControl 10 } sleY1731MegControlCcEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables MEPs to send Continuity Check messages" ::= { sleY1731MegControl 11 } sleY1731MegControlCcInterval OBJECT-TYPE SYNTAX Integer32 (1 | 2..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the interval between CCM transmissions" ::= { sleY1731MegControl 12 } sleY1731MegControlCcPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the CCM or LTM Message Priority" ::= { sleY1731MegControl 13 } sleY1731MegControlCcLossThreshold OBJECT-TYPE SYNTAX Integer32 (2..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the minimum number of CCMs that can be missed before declaring that a MEP is down" ::= { sleY1731MegControl 14 } sleY1731MegControlCcHoldTime OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the time that data of a missing MEP is kept" ::= { sleY1731MegControl 15 } sleY1731MegControlFaultPriority OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the lowest priority for fault alarm" ::= { sleY1731MegControl 16 } sleY1731MegControlFaultKeepTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the keep time for the fault alarm" ::= { sleY1731MegControl 17 } sleY1731MegControlFaultClearTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the clear time for the fault alarm" ::= { sleY1731MegControl 18 } sleY1731MegControlXcheckEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables Y.1731 cross-check for a specific MEG" ::= { sleY1731MegControl 19 } sleY1731MegControlAisEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables ETH-AIS function" ::= { sleY1731MegControl 20 } sleY1731MegControlAisTransmitEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables ETH-AIS frame transmission on a MEP" ::= { sleY1731MegControl 21 } sleY1731MegControlAisInterval OBJECT-TYPE SYNTAX INTEGER { oneSecond(4), oneMinute(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the interval between AIS transmissions" ::= { sleY1731MegControl 22 } sleY1731MegControlAisLevel OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the client MEG's level" ::= { sleY1731MegControl 23 } sleY1731MegControlAisPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the AIS Message Priority" ::= { sleY1731MegControl 24 } sleY1731MegControlLckEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables ETH-LCK function" ::= { sleY1731MegControl 25 } sleY1731MegControlLckTransmitEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables ETH-LCK frame transmission on a MEP" ::= { sleY1731MegControl 26 } sleY1731MegControlLckInterval OBJECT-TYPE SYNTAX INTEGER { oneSecond(4), oneMinute(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the interval between LCK transmissions" ::= { sleY1731MegControl 27 } sleY1731MegControlLckLevel OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the client MEG's level" ::= { sleY1731MegControl 28 } sleY1731MegControlLckPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the LCK Message Priority" ::= { sleY1731MegControl 29 } sleY1731MegControlOutOfService OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the out-of-service mode" ::= { sleY1731MegControl 30 } sleY1731MegControlRapsEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables R-APS node" ::= { sleY1731MegControl 31 } sleY1731MegControlRapsRplOwner OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the owner of the ring protection link" ::= { sleY1731MegControl 32 } sleY1731MegControlRapsEastPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the east port of R-APS node Set zero to delete east port" ::= { sleY1731MegControl 33 } sleY1731MegControlRapsWestPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the west port of R-APS node Set zero to delete west port" ::= { sleY1731MegControl 34 } sleY1731MegControlRapsRplPort OBJECT-TYPE SYNTAX INTEGER { none(-1), east(0), west(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the RPL port of R-APS node" ::= { sleY1731MegControl 35 } sleY1731MegControlRapsHoldOffTime OBJECT-TYPE SYNTAX Integer32 (0..10000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the hold-off time for verifying local SF The hold-off time's step must be 100 " ::= { sleY1731MegControl 36 } sleY1731MegControlRapsGuardTime OBJECT-TYPE SYNTAX Integer32 (10..2000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the guard time for verifying local clear SF The guard time's step must be 10 " ::= { sleY1731MegControl 37 } sleY1731MegControlRapsWaitToRestore OBJECT-TYPE SYNTAX Integer32 (5..720) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the wait-to-restore time for verifying remote SF " ::= { sleY1731MegControl 38 } sleY1731MegControlRapsNonRevertive OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "NonRevertive" ::= { sleY1731MegControl 39 } sleY1731MegControlRapsForcedSwitchEast OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "ForcedSwitchEast" ::= { sleY1731MegControl 40 } sleY1731MegControlRapsForcedSwitchWest OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "ForcedSwitchWest" ::= { sleY1731MegControl 41 } sleY1731MegControlMd OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "The MD name of MEG." ::= { sleY1731MegControl 42 } sleY1731MegNotification OBJECT IDENTIFIER ::= { sleY1731Meg 3 } sleY1731MegCreated NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlLevel, sleY1731MegControlVid } STATUS current DESCRIPTION "createY1731Meg" ::= { sleY1731MegNotification 1 } sleY1731MegDeleted NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName } STATUS current DESCRIPTION "deleteY1731Meg" ::= { sleY1731MegNotification 2 } sleY1731MegMepEnableChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName, sleY1731MegControlMepEnable } STATUS current DESCRIPTION "setY1731MepEnable" ::= { sleY1731MegNotification 3 } sleY1731MegCcEnableChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlCcEnable } STATUS current DESCRIPTION "setY1731CcEnable" ::= { sleY1731MegNotification 4 } sleY1731MegCcProfileChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName, sleY1731MegControlCcInterval, sleY1731MegControlCcPriority, sleY1731MegControlCcLossThreshold, sleY1731MegControlCcHoldTime } STATUS current DESCRIPTION "setY1731CcProfile" ::= { sleY1731MegNotification 5 } sleY1731MegFaultProfileChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName, sleY1731MegControlFaultPriority, sleY1731MegControlFaultKeepTime, sleY1731MegControlFaultClearTime } STATUS current DESCRIPTION "setY1731FaultProfile" ::= { sleY1731MegNotification 6 } sleY1731MegXcheckEnableChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName, sleY1731MegControlXcheckEnable } STATUS current DESCRIPTION "setY1731XcheckEnable" ::= { sleY1731MegNotification 7 } sleY1731MegAisEnableChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName, sleY1731MegControlAisEnable } STATUS current DESCRIPTION "setY1731AisEnable" ::= { sleY1731MegNotification 8 } sleY1731MegAisTransmitEnableChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName, sleY1731MegControlAisTransmitEnable } STATUS current DESCRIPTION "setY1731AisTransmitEnable" ::= { sleY1731MegNotification 9 } sleY1731MegAisProfileChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName, sleY1731MegControlAisInterval, sleY1731MegControlAisLevel, sleY1731MegControlAisPriority } STATUS current DESCRIPTION "setY1731AisProfile" ::= { sleY1731MegNotification 10 } sleY1731MegLckEnableChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName, sleY1731MegControlLckEnable } STATUS current DESCRIPTION "setY1731LckEnable" ::= { sleY1731MegNotification 11 } sleY1731MegLckTransmitEnableChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName, sleY1731MegControlLckTransmitEnable } STATUS current DESCRIPTION "setY1731LckTransmitEnable" ::= { sleY1731MegNotification 12 } sleY1731MegLckProfileChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName, sleY1731MegControlLckInterval, sleY1731MegControlLckLevel, sleY1731MegControlLckPriority } STATUS current DESCRIPTION "setY1731LckProfile" ::= { sleY1731MegNotification 13 } sleY1731MegOutOfServiceChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName, sleY1731MegControlOutOfService } STATUS current DESCRIPTION "setY1731OutOfService" ::= { sleY1731MegNotification 14 } sleY1731MegRapsEnableChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName, sleY1731MegControlRapsEnable } STATUS current DESCRIPTION "setY1731RapsEnable" ::= { sleY1731MegNotification 15 } sleY1731MegRapsRingportsChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName, sleY1731MegControlRapsEastPort, sleY1731MegControlRapsWestPort } STATUS current DESCRIPTION "setY1731RapsProfile" ::= { sleY1731MegNotification 16 } sleY1731MegRapsRplPortChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName, sleY1731MegControlRapsRplPort } STATUS current DESCRIPTION "Description." ::= { sleY1731MegNotification 17 } sleY1731MegRapsRplOwnerChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName, sleY1731MegControlRapsRplOwner } STATUS current DESCRIPTION "Description." ::= { sleY1731MegNotification 18 } sleY1731MegRapsTimerChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName, sleY1731MegControlRapsHoldOffTime, sleY1731MegControlRapsGuardTime, sleY1731MegControlRapsWaitToRestore } STATUS current DESCRIPTION "Description." ::= { sleY1731MegNotification 19 } sleY1731MegRemoteMepDestroyed NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex } STATUS current DESCRIPTION "destroyRemoteMep" ::= { sleY1731MegNotification 20 } sleY1731MegErrorDestroyed NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex } STATUS current DESCRIPTION "destroyError" ::= { sleY1731MegNotification 21 } sleY1731MegRapsNonRevertiveChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlRapsNonRevertive } STATUS current DESCRIPTION "sleY1731MegRapsNonRevertiveChanged" ::= { sleY1731MegNotification 22 } sleY1731MegRapsForcedSwitchEastChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlRapsForcedSwitchEast } STATUS current DESCRIPTION "sleY1731MegRapsForcedSwitchEastChanged" ::= { sleY1731MegNotification 23 } sleY1731MegRapsForcedSwitchWestChanged NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlRapsForcedSwitchWest } STATUS current DESCRIPTION "sleY1731MegRapsForcedSwitchWestChanged" ::= { sleY1731MegNotification 24 } sleY1731MegMdAdded NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlMd } STATUS current DESCRIPTION "createY1731Meg" ::= { sleY1731MegNotification 25 } sleY1731MegMdDeleted NOTIFICATION-TYPE OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlMd } STATUS current DESCRIPTION "createY1731Meg" ::= { sleY1731MegNotification 26 } sleY1731Mep OBJECT IDENTIFIER ::= { sleY1731Oam 3 } sleY1731MepTable OBJECT-TYPE SYNTAX SEQUENCE OF SleY1731MepEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleY1731Mep 1 } sleY1731MepEntry OBJECT-TYPE SYNTAX SleY1731MepEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleY1731MegIndex, sleY1731MepIdentifier } ::= { sleY1731MepTable 1 } SleY1731MepEntry ::= SEQUENCE { sleY1731MepIdentifier Integer32, sleY1731MepIfIndex Integer32, sleY1731MepDirection INTEGER, sleY1731MepEnable INTEGER, sleY1731MepFngState INTEGER, sleY1731MepCcEnable INTEGER, sleY1731MepMacAddress OCTET STRING, sleY1731MepFaultPriority INTEGER, sleY1731MepFaultKeepTime Integer32, sleY1731MepFaultClearTime Integer32, sleY1731MepHighestPrDefect INTEGER, sleY1731MepAisEnable INTEGER, sleY1731MepAisTransmitEnable INTEGER, sleY1731MepLckEnable INTEGER, sleY1731MepLckTransmitEnable INTEGER, sleY1731MepOutOfService INTEGER, sleY1731MepDlmEnabledRmep Integer32, sleY1731MepDefects BITS, sleY1731MepCcmSequenceErrors Counter32, sleY1731MepCciSentCcms Counter32, sleY1731MepNextLbmTransId Integer32, sleY1731MepLbSuccessRate Integer32, sleY1731MepLbRoundtripMin Counter32, sleY1731MepLbRoundtripMax Counter32, sleY1731MepLbRoundtripAvg Counter32, sleY1731MepLbrIn Counter32, sleY1731MepLbrInOutOfOrder Counter32, sleY1731MepTstLbrInBitError Counter32, sleY1731MepTstLbrInCrcError Counter32, sleY1731MepLtmNextSeqNumber Integer32, sleY1731MepUnexpLtrIn Counter32, sleY1731MepLbrOut Counter32, sleY1731MepTmLbmCount Integer32, sleY1731MepTmLbrCount Integer32, sleY1731MepTmLbrFirstLostId Integer32, sleY1731MepTmLbrMaxRate Integer32, sleY1731MepTmTstCount Integer32, sleY1731MepCcmFrameLossNearMin Integer32, sleY1731MepCcmFrameLossNearMax Integer32, sleY1731MepCcmFrameLossNearSum Integer32, sleY1731MepCcmFrameLossFarMin Integer32, sleY1731MepCcmFrameLossFarMax Integer32, sleY1731MepCcmFrameLossFarSum Integer32, sleY1731MepPmEnable INTEGER, sleY1731MepCcmFrameLossNearRatio Integer32, sleY1731MepCcmFrameLossNearAvgRatio Integer32, sleY1731MepCcmFrameLossFarRatio Integer32, sleY1731MepCcmFrameLossFarAvgRatio Integer32, sleY1731MepRllcf INTEGER, sleY1731MepRllcfHoldOff Integer32, sleY1731MepRllcfGuardTime Integer32 } sleY1731MepIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "MEP Id" ::= { sleY1731MepEntry 1 } sleY1731MepIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Brige Port Index whitch the MEP is attached" ::= { sleY1731MepEntry 2 } sleY1731MepDirection OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The direction in which the MEP faces on the Bridge port" ::= { sleY1731MepEntry 3 } sleY1731MepEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Administrative state of the MEP" ::= { sleY1731MepEntry 4 } sleY1731MepFngState OBJECT-TYPE SYNTAX INTEGER { reset(1), defect(2), reportDefect(3), defectReported(4), defectCearing(5), defectCleared(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current state of the MEP Fault Notification Generator State Machine" ::= { sleY1731MepEntry 5 } sleY1731MepCcEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "If set to true, the MEP will generate CCM messages" ::= { sleY1731MepEntry 6 } sleY1731MepMacAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-only STATUS current DESCRIPTION "MAC address of the MEP" ::= { sleY1731MepEntry 7 } sleY1731MepFaultPriority OBJECT-TYPE SYNTAX INTEGER { rdi(1), loc(2), unp(3), unm(4), mmg(5), unl(6), ais(7), lck(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "An integer value specifying the lowest priority defect that is allowed to generate fault alarm" ::= { sleY1731MepEntry 8 } sleY1731MepFaultKeepTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-only STATUS current DESCRIPTION "The time that defects must be present before a Fault Alarm is issued" ::= { sleY1731MepEntry 9 } sleY1731MepFaultClearTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-only STATUS current DESCRIPTION "The time that defects must be absent before resetting a Fault Alarm" ::= { sleY1731MepEntry 10 } sleY1731MepHighestPrDefect OBJECT-TYPE SYNTAX INTEGER { rdi(1), loc(2), unp(3), unm(4), mmg(5), unl(6), ais(7), lck(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The highest priority defect that has been present since the MEPs Fault Notification Generator State Machine was last in the FNG_RESET state" ::= { sleY1731MepEntry 11 } sleY1731MepAisEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "If set to true, the AIS function for the MEP is enabled" ::= { sleY1731MepEntry 12 } sleY1731MepAisTransmitEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "If set to true, the MEP can generate AIS messages" ::= { sleY1731MepEntry 13 } sleY1731MepLckEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "If set to true, the LCK function for the MEP is enabled" ::= { sleY1731MepEntry 14 } sleY1731MepLckTransmitEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "If set to true, the MEP can generate LCK messages" ::= { sleY1731MepEntry 15 } sleY1731MepOutOfService OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "If set to true, the MEP is in out-of-service." ::= { sleY1731MepEntry 16 } sleY1731MepDlmEnabledRmep OBJECT-TYPE SYNTAX Integer32 (0..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "The RMEP identifier enabled DLM functin If set to zero, disabled DLM function. " ::= { sleY1731MepEntry 17 } sleY1731MepDefects OBJECT-TYPE SYNTAX BITS { rdi(0), loc(1), unp(2), unm(3), mmg(4), unl(5), ais(6), lck(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "A vector of Boolean defect conditions" ::= { sleY1731MepEntry 18 } sleY1731MepCcmSequenceErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of out-of-sequence CCMs received from all remote MEPs" ::= { sleY1731MepEntry 19 } sleY1731MepCciSentCcms OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of Continuity Check messages transmitted" ::= { sleY1731MepEntry 20 } sleY1731MepNextLbmTransId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Next sequence number/transaction identifier to be sent in a Loopback message" ::= { sleY1731MepEntry 21 } sleY1731MepLbSuccessRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Loopback Success rate" ::= { sleY1731MepEntry 22 } sleY1731MepLbRoundtripMin OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum round trip time of Loopback message" ::= { sleY1731MepEntry 23 } sleY1731MepLbRoundtripMax OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum round trip time of Loopback message" ::= { sleY1731MepEntry 24 } sleY1731MepLbRoundtripAvg OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average round trip time of Loopback message" ::= { sleY1731MepEntry 25 } sleY1731MepLbrIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of valid, in-order Loopback Replies received" ::= { sleY1731MepEntry 26 } sleY1731MepLbrInOutOfOrder OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid, out-of-order Loopback Replies received" ::= { sleY1731MepEntry 27 } sleY1731MepTstLbrInBitError OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of invalid, bit-error Loopback Replies received for diagnostic test" ::= { sleY1731MepEntry 28 } sleY1731MepTstLbrInCrcError OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of invalid, crc-error Loopback Replies received for diagnostic test" ::= { sleY1731MepEntry 29 } sleY1731MepLtmNextSeqNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Next transaction identifier/sequence number to be sent in a Linktrace message." ::= { sleY1731MepEntry 30 } sleY1731MepUnexpLtrIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of unexpected LTRs received" ::= { sleY1731MepEntry 31 } sleY1731MepLbrOut OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of Loopback Replies transmitted" ::= { sleY1731MepEntry 32 } sleY1731MepTmLbmCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the count of LBM frame for the throughput-measurement" ::= { sleY1731MepEntry 33 } sleY1731MepTmLbrCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the count of LBM frame for the throughput-measurement" ::= { sleY1731MepEntry 34 } sleY1731MepTmLbrFirstLostId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the transaction identifier of first lost LBR frame for the throughput-measurement" ::= { sleY1731MepEntry 35 } sleY1731MepTmLbrMaxRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the maximum transmission rate" ::= { sleY1731MepEntry 36 } sleY1731MepTmTstCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the count of TST message for the throughput-measurement" ::= { sleY1731MepEntry 37 } sleY1731MepCcmFrameLossNearMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the minimum of dual-ended near-end frame loss" ::= { sleY1731MepEntry 38 } sleY1731MepCcmFrameLossNearMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the maximum of dual-ended near-end frame loss" ::= { sleY1731MepEntry 39 } sleY1731MepCcmFrameLossNearSum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the sum of dual-ended near-end frame loss" ::= { sleY1731MepEntry 40 } sleY1731MepCcmFrameLossFarMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the minimum of dual-ended far-end frame loss" ::= { sleY1731MepEntry 41 } sleY1731MepCcmFrameLossFarMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the maximum of dual-ended far-end frame loss" ::= { sleY1731MepEntry 42 } sleY1731MepCcmFrameLossFarSum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the sum of dual-ended far-end frame loss" ::= { sleY1731MepEntry 43 } sleY1731MepPmEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "If set to true, the PM(performance monitoring) of the MEP is enabled" ::= { sleY1731MepEntry 44 } sleY1731MepCcmFrameLossNearRatio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ratio of dual-ended near-end frame loss" ::= { sleY1731MepEntry 45 } sleY1731MepCcmFrameLossNearAvgRatio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the average ratio of dual-ended near-end frame loss" ::= { sleY1731MepEntry 46 } sleY1731MepCcmFrameLossFarRatio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ratio of dual-ended far-end frame loss" ::= { sleY1731MepEntry 47 } sleY1731MepCcmFrameLossFarAvgRatio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the average ratio of dual-ended far-end frame loss" ::= { sleY1731MepEntry 48 } sleY1731MepRllcf OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "If set to true, the MEP is a MEP of client link for remote link loss carry forward." ::= { sleY1731MepEntry 49 } sleY1731MepRllcfHoldOff OBJECT-TYPE SYNTAX Integer32 (10..3000) MAX-ACCESS read-only STATUS current DESCRIPTION "It is a Hold-off time of Remote LLCF and its unit is millisecond, interval is 10ms." ::= { sleY1731MepEntry 50 } sleY1731MepRllcfGuardTime OBJECT-TYPE SYNTAX Integer32 (100..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "It is a Guard time of Remote LLCF and its unit is millisecond, interval is 100ms.(default:500)" ::= { sleY1731MepEntry 51 } sleY1731MepControl OBJECT IDENTIFIER ::= { sleY1731Mep 2 } sleY1731MepControlRequest OBJECT-TYPE SYNTAX INTEGER { createY1731Mep(1), deleteY1731Mep(2), setY1731MepEnable(3), setY1731MepCcEnable(4), setY1731MepFaultProfile(5), setY1731MepAisEnable(6), setY1731MepAisTransmitEnable(7), setY1731MepLckEnable(8), setY1731MepLckTransmitEnable(9), setY1731MepOutOfService(10), setY1731MepDlmEnable(11), transmitY1731Lbm(12), transmitY1731Ltm(13), transmitY1731TstLbm(14), transmitY1731TmLbm(15), transmitY1731Tst(16), receiveY1731Tst(17), transmitY1731TmTst(18), receiveY1731TmTst(19), transmitY1731Lmm(20), transmitY17311dm(21), receiveY17311dm(22), transmitY1731dmm(23), setY1731MepPmEnable(24), setY1731MepRllcf(25) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731MepControl 1 } sleY1731MepControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731MepControl 2 } sleY1731MepControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731MepControl 3 } sleY1731MepControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731MepControl 4 } sleY1731MepControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731MepControl 5 } sleY1731MepControlIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "MEP Id" ::= { sleY1731MepControl 6 } sleY1731MepControlMegIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "A index of MEG table" ::= { sleY1731MepControl 7 } sleY1731MepControlIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Bridge Port Index whitch the MEP is attached" ::= { sleY1731MepControl 8 } sleY1731MepControlDirection OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The direction in which the MEP faces on the Bridge port" ::= { sleY1731MepControl 9 } sleY1731MepControlEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Administrative state of the MEP" ::= { sleY1731MepControl 10 } sleY1731MepControlCcEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "If set to true, the MEP will generate CCM messages" ::= { sleY1731MepControl 11 } sleY1731MepControlFaultPriority OBJECT-TYPE SYNTAX INTEGER { rdi(1), loc(2), unp(3), unm(4), mmg(5), unl(6), ais(7), lck(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "An integer value specifying the lowest priority defect that is allowed to generate fault alarm" ::= { sleY1731MepControl 12 } sleY1731MepControlFaultKeepTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-write STATUS current DESCRIPTION "The time that defects must be present before a Fault Alarm is issued" ::= { sleY1731MepControl 13 } sleY1731MepControlFaultClearTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-write STATUS current DESCRIPTION "The time that defects must be absent before resetting a Fault Alarm" ::= { sleY1731MepControl 14 } sleY1731MepControlAisEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "If set to true, the AIS function for the MEP is enabled" ::= { sleY1731MepControl 15 } sleY1731MepControlAisTransmitEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "If set to true, the MEP can generate AIS messages" ::= { sleY1731MepControl 16 } sleY1731MepControlLckEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "If set to true, the LCK function for the MEP is enabled" ::= { sleY1731MepControl 17 } sleY1731MepControlLckTransmitEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "If set to true, the MEP can generate LCK messages" ::= { sleY1731MepControl 18 } sleY1731MepControlOutOfService OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "If set to true, the MEP is in out-of-service." ::= { sleY1731MepControl 19 } sleY1731MepControlDlmEnabledRmep OBJECT-TYPE SYNTAX Integer32 (0..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "The RMEP identifier enabled DLM functin If set to zero, disabled DLM function. " ::= { sleY1731MepControl 20 } sleY1731MepControlTransmitLbmIsUnicast OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates transmitting unicast or multicast frame" ::= { sleY1731MepControl 21 } sleY1731MepControlTransmitLbmDestMacAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-write STATUS current DESCRIPTION "The Target MAC Address Field to be transmitted" ::= { sleY1731MepControl 22 } sleY1731MepControlTransmitLbmDestMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the LBM is to be sent" ::= { sleY1731MepControl 23 } sleY1731MepControlTransmitLbmDestIsMepId OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "True indicates that MEPID of the target MEP is used for Loopback transmission" ::= { sleY1731MepControl 24 } sleY1731MepControlTransmitLbmCount OBJECT-TYPE SYNTAX Integer32 (1..6000) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of Loopback messages to be transmitted" ::= { sleY1731MepControl 25 } sleY1731MepControlTransmitLbmInterval OBJECT-TYPE SYNTAX Integer32 (2..4) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the interval for sending LBM" ::= { sleY1731MepControl 26 } sleY1731MepControlTransmitLbmTimeout OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the waiting time for receiving the expected LBR" ::= { sleY1731MepControl 27 } sleY1731MepControlTransmitLbmPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Priority. 3 bit value to be used in the VLAN tag" ::= { sleY1731MepControl 28 } sleY1731MepControlTransmitLbmLength OBJECT-TYPE SYNTAX Integer32 (5..1400) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the length of Data TLV" ::= { sleY1731MepControl 29 } sleY1731MepControlTransmitLtmTargetMacAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-write STATUS current DESCRIPTION "The Target MAC Address Field to be transmitted: A unicast destination MAC address." ::= { sleY1731MepControl 30 } sleY1731MepControlTransmitLtmTargetMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "An indication of the Target MAC Address Field to be transmitted" ::= { sleY1731MepControl 31 } sleY1731MepControlTransmitLtmTargetIsMepId OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "True indicates that MEPID of the target MEP is used for Linktrace transmission." ::= { sleY1731MepControl 32 } sleY1731MepControlTransmitLtmFlags OBJECT-TYPE SYNTAX BITS { useFDBonly(0) } MAX-ACCESS read-write STATUS current DESCRIPTION "The flags field for LTMs transmitted by the MEP" ::= { sleY1731MepControl 33 } sleY1731MepControlTransmitLtmTtl OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-write STATUS current DESCRIPTION "The LTM TTL field" ::= { sleY1731MepControl 34 } sleY1731MepControlTransmitLtmPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Priority. 3 bit value to be used in the VLAN tag" ::= { sleY1731MepControl 35 } sleY1731MepControlTransmitTstLbmDestMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the LBM is to be sent" ::= { sleY1731MepControl 36 } sleY1731MepControlTransmitTstLbmDuration OBJECT-TYPE SYNTAX Integer32 (5..6000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the duration to send LBM" ::= { sleY1731MepControl 37 } sleY1731MepControlTransmitTstLbmInterval OBJECT-TYPE SYNTAX Integer32 (2..4) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the interval for sending LBM" ::= { sleY1731MepControl 38 } sleY1731MepControlTransmitTstLbmTimeout OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the waiting time for receiving the expected LBR" ::= { sleY1731MepControl 39 } sleY1731MepControlTransmitTstLbmPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Priority. 3 bit value to be used in the VLAN tag" ::= { sleY1731MepControl 40 } sleY1731MepControlTransmitTstLbmLength OBJECT-TYPE SYNTAX Integer32 (5..1400) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the length of Test TLV" ::= { sleY1731MepControl 41 } sleY1731MepControlTransmitTstLbmPattern OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the pattern of Test TLV used for diagnostic test" ::= { sleY1731MepControl 42 } sleY1731MepControlTransmitTmLbmDestMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the LBM is to be sent" ::= { sleY1731MepControl 43 } sleY1731MepControlTransmitTmLbmDuration OBJECT-TYPE SYNTAX Integer32 (5..6000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the duration to send LBM" ::= { sleY1731MepControl 44 } sleY1731MepControlTransmitTmLbmPartDuration OBJECT-TYPE SYNTAX Integer32 (1..5) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the part duration of LBM to be transmitted at the same transmission rate" ::= { sleY1731MepControl 45 } sleY1731MepControlTransmitTmLbmStartRate OBJECT-TYPE SYNTAX Integer32 (100..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the the number of LBMs to be transmitted per second at first time" ::= { sleY1731MepControl 46 } sleY1731MepControlTransmitTmLbmIncRate OBJECT-TYPE SYNTAX Integer32 (100..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the increment of number of LBMs to be transmitted" ::= { sleY1731MepControl 47 } sleY1731MepControlTransmitTmLbmTimeout OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the waiting time for receiving the expected LBR" ::= { sleY1731MepControl 48 } sleY1731MepControlTransmitTmLbmPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Priority. 3 bit value to be used in the VLAN tag" ::= { sleY1731MepControl 49 } sleY1731MepControlTransmitTmLbmLength OBJECT-TYPE SYNTAX Integer32 (5..1400) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the length of Test TLV" ::= { sleY1731MepControl 50 } sleY1731MepControlTransmitTmLbmPattern OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the pattern of Test TLV used for diagnostic test" ::= { sleY1731MepControl 51 } sleY1731MepControlTransmitTstIsUnicast OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates transmitting unicast or multicast frame" ::= { sleY1731MepControl 52 } sleY1731MepControlTransmitTstDestMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the TST is to be sent" ::= { sleY1731MepControl 53 } sleY1731MepControlTransmitTstDuration OBJECT-TYPE SYNTAX Integer32 (5..6000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the duration to send TST" ::= { sleY1731MepControl 54 } sleY1731MepControlTransmitTstInterval OBJECT-TYPE SYNTAX Integer32 (2..4) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the interval for sending TST" ::= { sleY1731MepControl 55 } sleY1731MepControlTransmitTstPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Priority. 3 bit value to be used in the VLAN tag" ::= { sleY1731MepControl 56 } sleY1731MepControlTransmitTstLength OBJECT-TYPE SYNTAX Integer32 (5..1400) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the length of Test TLV" ::= { sleY1731MepControl 57 } sleY1731MepControlTransmitTstPattern OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the pattern of Test TLV used for diagnostic test" ::= { sleY1731MepControl 58 } sleY1731MepControlReceiveTstDuration OBJECT-TYPE SYNTAX Integer32 (5..6000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the duration to receive TST" ::= { sleY1731MepControl 59 } sleY1731MepControlTransmitTmTstIsUnicast OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates transmitting unicast or multicast frame" ::= { sleY1731MepControl 60 } sleY1731MepControlTransmitTmTstDestMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the TST is to be sent" ::= { sleY1731MepControl 61 } sleY1731MepControlTransmitTmTstDuration OBJECT-TYPE SYNTAX Integer32 (5..6000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the duration to send TST" ::= { sleY1731MepControl 62 } sleY1731MepControlTransmitTmTstPartDuration OBJECT-TYPE SYNTAX Integer32 (1..5) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the part duration of TST to be transmitted at the same transmission rate" ::= { sleY1731MepControl 63 } sleY1731MepControlTransmitTmTstStartRate OBJECT-TYPE SYNTAX Integer32 (100..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the the number of TSTs to be transmitted per second at first time" ::= { sleY1731MepControl 64 } sleY1731MepControlTransmitTmTstIncRate OBJECT-TYPE SYNTAX Integer32 (100..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the increment of number of TSTs to be transmitted" ::= { sleY1731MepControl 65 } sleY1731MepControlTransmitTmTstTimeout OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the waiting time for receiving the expected LBR" ::= { sleY1731MepControl 66 } sleY1731MepControlTransmitTmTstPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Priority. 3 bit value to be used in the VLAN tag" ::= { sleY1731MepControl 67 } sleY1731MepControlTransmitTmTstLength OBJECT-TYPE SYNTAX Integer32 (5..1400) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the length of Test TLV" ::= { sleY1731MepControl 68 } sleY1731MepControlTransmitTmTstPattern OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the pattern of Test TLV used for diagnostic test" ::= { sleY1731MepControl 69 } sleY1731MepControlReceiveTmTstDuration OBJECT-TYPE SYNTAX Integer32 (5..6000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the duration to receive TST" ::= { sleY1731MepControl 70 } sleY1731MepControlTransmitLmmIsUnicast OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "A flag to indicates transmitting unicast or multicast frame" ::= { sleY1731MepControl 71 } sleY1731MepControlTransmitLmmDestMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the LMM is to be sent" ::= { sleY1731MepControl 72 } sleY1731MepControlTransmitLmmDuration OBJECT-TYPE SYNTAX Integer32 (5..6000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the duration to send LMM" ::= { sleY1731MepControl 73 } sleY1731MepControlTransmitLmmInterval OBJECT-TYPE SYNTAX Integer32 (2..4) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the interval for sending LMM" ::= { sleY1731MepControl 74 } sleY1731MepControlTransmitLmmTimeout OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the waiting time for receiving the expected LMM" ::= { sleY1731MepControl 75 } sleY1731MepControlTransmitLmmPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Priority. 3 bit value to be used in the VLAN tag" ::= { sleY1731MepControl 76 } sleY1731MepControlTransmit1dmIsUnicast OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "A flag to indicates transmitting unicast or multicast frame" ::= { sleY1731MepControl 77 } sleY1731MepControlTransmit1dmDestMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the 1DM is to be sent" ::= { sleY1731MepControl 78 } sleY1731MepControlTransmit1dmDuration OBJECT-TYPE SYNTAX Integer32 (5..6000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the duration to send 1DM" ::= { sleY1731MepControl 79 } sleY1731MepControlTransmit1dmInterval OBJECT-TYPE SYNTAX Integer32 (2..4) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the interval for sending 1DM" ::= { sleY1731MepControl 80 } sleY1731MepControlTransmit1dmPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Priority. 3 bit value to be used in the VLAN tag" ::= { sleY1731MepControl 81 } sleY1731MepControlReceive1dmDuration OBJECT-TYPE SYNTAX Integer32 (5..6000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the duration to receive 1DM" ::= { sleY1731MepControl 82 } sleY1731MepControlTransmitDmmIsUnicast OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "A flag to indicates transmitting unicast or multicast frame" ::= { sleY1731MepControl 83 } sleY1731MepControlTransmitDmmDestMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the DMM is to be sent" ::= { sleY1731MepControl 84 } sleY1731MepControlTransmitDmmDuration OBJECT-TYPE SYNTAX Integer32 (5..6000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the duration to send DMM" ::= { sleY1731MepControl 85 } sleY1731MepControlTransmitDmmInterval OBJECT-TYPE SYNTAX Integer32 (2..4) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the interval for sending DMM" ::= { sleY1731MepControl 86 } sleY1731MepControlTransmitDmmTimeout OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the waiting time for receiving the expected DMM" ::= { sleY1731MepControl 87 } sleY1731MepControlTransmitDmmPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Priority. 3 bit value to be used in the VLAN tag" ::= { sleY1731MepControl 88 } sleY1731MepControlPmEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "If set to true, the PM(performance monitoring) of the MEP is enabled" ::= { sleY1731MepControl 89 } sleY1731MepControlRllcf OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "If set to true, the MEP is a MEP of client link for remote link loss carry forward." ::= { sleY1731MepControl 90 } sleY1731MepControlRllcfHoldOff OBJECT-TYPE SYNTAX Integer32 (10..3000) MAX-ACCESS read-write STATUS current DESCRIPTION "It is a Hold-off time of Remote LLCF and its unit is millisecond, interval is 10ms." ::= { sleY1731MepControl 91 } sleY1731MepControlRllcfGuardTime OBJECT-TYPE SYNTAX Integer32 (100..10000) MAX-ACCESS read-write STATUS current DESCRIPTION "It is a Guard time of Remote LLCF and its unit is millisecond, interval is 100ms.(default:500)" ::= { sleY1731MepControl 92 } sleY1731MepNotification OBJECT IDENTIFIER ::= { sleY1731Mep 3 } sleY1731MepCreated NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex, sleY1731MepControlIfIndex, sleY1731MepControlDirection } STATUS current DESCRIPTION "createY1731Mep" ::= { sleY1731MepNotification 1 } sleY1731MepDeleted NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex } STATUS current DESCRIPTION "deleteY1731Mep" ::= { sleY1731MepNotification 2 } sleY1731MepEnableChanged NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex, sleY1731MepControlEnable } STATUS current DESCRIPTION "setY1731MepEnable" ::= { sleY1731MepNotification 3 } sleY1731MepCcEnableChanged NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex, sleY1731MepControlCcEnable } STATUS current DESCRIPTION "setY1731CcEnable" ::= { sleY1731MepNotification 4 } sleY1731MepFaultProfileChanged NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex, sleY1731MepControlFaultPriority, sleY1731MepControlFaultKeepTime, sleY1731MepControlFaultClearTime } STATUS current DESCRIPTION "setY1731FaultProfile" ::= { sleY1731MepNotification 5 } sleY1731MepAisEnableChanged NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex, sleY1731MepControlAisEnable } STATUS current DESCRIPTION "setY1731AisEnable" ::= { sleY1731MepNotification 6 } sleY1731MepAisTransmitEnableChanged NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex, sleY1731MepControlAisTransmitEnable } STATUS current DESCRIPTION "setY1731AisTransmitEnable" ::= { sleY1731MepNotification 7 } sleY1731MepLckEnableChanged NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex, sleY1731MepControlLckEnable } STATUS current DESCRIPTION "setY1731LckEnable" ::= { sleY1731MepNotification 8 } sleY1731MepLckTransmitEnableChanged NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex, sleY1731MepControlLckTransmitEnable } STATUS current DESCRIPTION "setY1731LckTransmitEnable" ::= { sleY1731MepNotification 9 } sleY1731MepOutOfServiceChanged NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex, sleY1731MepControlOutOfService } STATUS current DESCRIPTION "setY1731OutOfService" ::= { sleY1731MepNotification 10 } sleY1731MepDlmEnableChanged NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex, sleY1731MepControlDlmEnabledRmep } STATUS current DESCRIPTION "setY1731DlmEnable" ::= { sleY1731MepNotification 11 } sleY1731MepTransmitLbmFinished NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex } STATUS current DESCRIPTION "transmitY1731Lbm" ::= { sleY1731MepNotification 12 } sleY1731MepTransmitLtmFinished NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex } STATUS current DESCRIPTION "transmitY1731Ltm" ::= { sleY1731MepNotification 13 } sleY1731MepTransmitTstLbmFinished NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex } STATUS current DESCRIPTION "transmitY1731TstLbm" ::= { sleY1731MepNotification 14 } sleY1731MepTransmitTmLbmFinished NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex } STATUS current DESCRIPTION "transmitY1731TmLbm" ::= { sleY1731MepNotification 15 } sleY1731MepTransmitTstFinished NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex } STATUS current DESCRIPTION "transmitY1731Tst" ::= { sleY1731MepNotification 16 } sleY1731MepReceiveTstFinished NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex } STATUS current DESCRIPTION "receiveY1731Tst" ::= { sleY1731MepNotification 17 } sleY1731MepTransmitTmTstFinished NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex } STATUS current DESCRIPTION "transmitY1731TmTst" ::= { sleY1731MepNotification 18 } sleY1731MepReceiveTmTstFinished NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex } STATUS current DESCRIPTION "receiveY1731TmTst" ::= { sleY1731MepNotification 19 } sleY1731MepTransmitLmmFinished NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex } STATUS current DESCRIPTION "transmitY1731Lmm" ::= { sleY1731MepNotification 20 } sleY1731MepTransmit1dmFinished NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex } STATUS current DESCRIPTION "transmitY17311dm" ::= { sleY1731MepNotification 21 } sleY1731MepReceive1dmFinished NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex } STATUS current DESCRIPTION "receiveY17311dm" ::= { sleY1731MepNotification 22 } sleY1731MepTransmitDmmFinished NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex } STATUS current DESCRIPTION "transmitY1731Dmm" ::= { sleY1731MepNotification 23 } sleY1731MepPmEnableChanged NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex, sleY1731MepControlPmEnable } STATUS current DESCRIPTION "setY1731PmEnable" ::= { sleY1731MepNotification 24 } sleY1731MepRllcfChanged NOTIFICATION-TYPE OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex, sleY1731MepControlRllcf, sleY1731MepControlRllcfHoldOff, sleY1731MepControlRllcfGuardTime } STATUS current DESCRIPTION "setY1731MepRllcf" ::= { sleY1731MepNotification 25 } sleY1731Mip OBJECT IDENTIFIER ::= { sleY1731Oam 4 } sleY1731MipTable OBJECT-TYPE SYNTAX SEQUENCE OF SleY1731MipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleY1731Mip 1 } sleY1731MipEntry OBJECT-TYPE SYNTAX SleY1731MipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleY1731MipPort } ::= { sleY1731MipTable 1 } SleY1731MipEntry ::= SEQUENCE { sleY1731MipPort Integer32, sleY1731MipLevel Integer32, sleY1731MipType INTEGER } sleY1731MipPort OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the port number" ::= { sleY1731MipEntry 1 } sleY1731MipLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the MIP's level" ::= { sleY1731MipEntry 2 } sleY1731MipType OBJECT-TYPE SYNTAX INTEGER { static(1), dynamic(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate the MIP¡¯s type" ::= { sleY1731MipEntry 3 } sleY1731MipControl OBJECT IDENTIFIER ::= { sleY1731Mip 2 } sleY1731MipControlRequest OBJECT-TYPE SYNTAX INTEGER { createY1731Mip(1), deleteY1731Mip(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731MipControl 1 } sleY1731MipControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731MipControl 2 } sleY1731MipControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731MipControl 3 } sleY1731MipControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731MipControl 4 } sleY1731MipControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731MipControl 5 } sleY1731MipControlPort OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the port number" ::= { sleY1731MipControl 6 } sleY1731MipControlLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the MIP's level" ::= { sleY1731MipControl 7 } sleY1731MipNotification OBJECT IDENTIFIER ::= { sleY1731Mip 3 } sleY1731MipCreated NOTIFICATION-TYPE OBJECTS { sleY1731MipControlRequest, sleY1731MipControlTimeStamp, sleY1731MipControlReqResult, sleY1731MipControlPort, sleY1731MipControlLevel } STATUS current DESCRIPTION "createY1731Mip" ::= { sleY1731MipNotification 1 } sleY1731MipDeleted NOTIFICATION-TYPE OBJECTS { sleY1731MipControlRequest, sleY1731MipControlTimeStamp, sleY1731MipControlReqResult, sleY1731MipControlPort } STATUS current DESCRIPTION "deleteY1731Mip" ::= { sleY1731MipNotification 2 } sleY1731Xcheck OBJECT IDENTIFIER ::= { sleY1731Oam 5 } sleY1731XcheckTable OBJECT-TYPE SYNTAX SEQUENCE OF SleY1731XcheckEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleY1731Xcheck 1 } sleY1731XcheckEntry OBJECT-TYPE SYNTAX SleY1731XcheckEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleY1731MegIndex, sleY1731XcheckMepIdentifier } ::= { sleY1731XcheckTable 1 } SleY1731XcheckEntry ::= SEQUENCE { sleY1731XcheckMepIdentifier Integer32, sleY1731XcheckMepState INTEGER } sleY1731XcheckMepIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the remote MEP's Id" ::= { sleY1731XcheckEntry 1 } sleY1731XcheckMepState OBJECT-TYPE SYNTAX INTEGER { unknown(0), missing(1), up(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the cross-check MEP¡¯s state" ::= { sleY1731XcheckEntry 2 } sleY1731XcheckControl OBJECT IDENTIFIER ::= { sleY1731Xcheck 2 } sleY1731XcheckControlRequest OBJECT-TYPE SYNTAX INTEGER { createY1731XcheckMep(1), deleteY1731XcheckMep(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731XcheckControl 1 } sleY1731XcheckControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731XcheckControl 2 } sleY1731XcheckControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731XcheckControl 3 } sleY1731XcheckControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731XcheckControl 4 } sleY1731XcheckControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731XcheckControl 5 } sleY1731XcheckControlMepIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the remote MEP's Id" ::= { sleY1731XcheckControl 6 } sleY1731XcheckControlMegIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the MEG¡¯s Index" ::= { sleY1731XcheckControl 7 } sleY1731XcheckNotification OBJECT IDENTIFIER ::= { sleY1731Xcheck 3 } sleY1731XcheckMepCreated NOTIFICATION-TYPE OBJECTS { sleY1731XcheckControlRequest, sleY1731XcheckControlTimeStamp, sleY1731XcheckControlReqResult, sleY1731XcheckControlMepIdentifier, sleY1731XcheckControlMegIndex } STATUS current DESCRIPTION "createY1731XcheckMep" ::= { sleY1731XcheckNotification 1 } sleY1731XcheckMepDeleted NOTIFICATION-TYPE OBJECTS { sleY1731XcheckControlRequest, sleY1731XcheckControlTimeStamp, sleY1731XcheckControlReqResult, sleY1731XcheckControlMepIdentifier, sleY1731XcheckControlMegIndex } STATUS current DESCRIPTION "deleteY1731XcheckMep" ::= { sleY1731XcheckNotification 2 } sleY1731CcMac OBJECT IDENTIFIER ::= { sleY1731Oam 6 } sleY1731CcMacTable OBJECT-TYPE SYNTAX SEQUENCE OF SleY1731CcMacEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleY1731CcMac 1 } sleY1731CcMacEntry OBJECT-TYPE SYNTAX SleY1731CcMacEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731CcMacAddress } ::= { sleY1731CcMacTable 1 } SleY1731CcMacEntry ::= SEQUENCE { sleY1731CcMacAddress OCTET STRING } sleY1731CcMacAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the unicast MAC address to send CCM" ::= { sleY1731CcMacEntry 1 } sleY1731CcMacControl OBJECT IDENTIFIER ::= { sleY1731CcMac 2 } sleY1731CcMacControlRequest OBJECT-TYPE SYNTAX INTEGER { createY1731CcMac(1), deleteY1731CcMac(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731CcMacControl 1 } sleY1731CcMacControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731CcMacControl 2 } sleY1731CcMacControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731CcMacControl 3 } sleY1731CcMacControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731CcMacControl 4 } sleY1731CcMacControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION "Result of the last command." ::= { sleY1731CcMacControl 5 } sleY1731CcMacControlMegIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the MEG's Index" ::= { sleY1731CcMacControl 6 } sleY1731CcMacControlMepIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "MEP Id" ::= { sleY1731CcMacControl 7 } sleY1731CcMacControlAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the unicast MAC address to send CCM When running deleteY1731CcMac, if this is zero-length, delete all unicast mac." ::= { sleY1731CcMacControl 8 } sleY1731CcMacNotification OBJECT IDENTIFIER ::= { sleY1731CcMac 3 } sleY1731CcMacCreated NOTIFICATION-TYPE OBJECTS { sleY1731CcMacControlRequest, sleY1731CcMacControlTimeStamp, sleY1731CcMacControlReqResult, sleY1731CcMacControlMegIndex, sleY1731CcMacControlMepIdentifier, sleY1731CcMacControlAddress } STATUS current DESCRIPTION "createY1731CcMac" ::= { sleY1731CcMacNotification 1 } sleY1731CcMacDeleted NOTIFICATION-TYPE OBJECTS { sleY1731CcMacControlRequest, sleY1731CcMacControlTimeStamp, sleY1731CcMacControlReqResult, sleY1731CcMacControlMegIndex, sleY1731CcMacControlMepIdentifier, sleY1731CcMacControlAddress } STATUS current DESCRIPTION "deleteY1731CcMac" ::= { sleY1731CcMacNotification 2 } sleY1731AisMac OBJECT IDENTIFIER ::= { sleY1731Oam 7 } sleY1731AisMacTable OBJECT-TYPE SYNTAX SEQUENCE OF SleY1731AisMacEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleY1731AisMac 1 } sleY1731AisMacEntry OBJECT-TYPE SYNTAX SleY1731AisMacEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731AisMacAddress } ::= { sleY1731AisMacTable 1 } SleY1731AisMacEntry ::= SEQUENCE { sleY1731AisMacAddress OCTET STRING } sleY1731AisMacAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the unicast MAC address to send AIS" ::= { sleY1731AisMacEntry 1 } sleY1731AisMacControl OBJECT IDENTIFIER ::= { sleY1731AisMac 2 } sleY1731AisMacControlRequest OBJECT-TYPE SYNTAX INTEGER { createY1731AisMac(1), deleteY1731AisMac(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731AisMacControl 1 } sleY1731AisMacControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731AisMacControl 2 } sleY1731AisMacControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731AisMacControl 3 } sleY1731AisMacControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731AisMacControl 4 } sleY1731AisMacControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731AisMacControl 5 } sleY1731AisMacControlMegIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the MEG's Index" ::= { sleY1731AisMacControl 6 } sleY1731AisMacControlMepIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "MEP Id" ::= { sleY1731AisMacControl 7 } sleY1731AisMacControlAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the unicast MAC address to send AIS When running deleteY1731AisMac, if this is zero-length, delete all unicast mac." ::= { sleY1731AisMacControl 8 } sleY1731AisMacNotification OBJECT IDENTIFIER ::= { sleY1731AisMac 3 } sleY1731AisMacCreated NOTIFICATION-TYPE OBJECTS { sleY1731AisMacControlRequest, sleY1731AisMacControlTimeStamp, sleY1731AisMacControlReqResult, sleY1731AisMacControlMegIndex, sleY1731AisMacControlMepIdentifier, sleY1731AisMacControlAddress } STATUS current DESCRIPTION "createY1731AisMac" ::= { sleY1731AisMacNotification 1 } sleY1731AisMacDeleted NOTIFICATION-TYPE OBJECTS { sleY1731AisMacControlRequest, sleY1731AisMacControlTimeStamp, sleY1731AisMacControlReqResult, sleY1731AisMacControlMegIndex, sleY1731AisMacControlMepIdentifier, sleY1731AisMacControlAddress } STATUS current DESCRIPTION "deleteY1731AisMac" ::= { sleY1731AisMacNotification 2 } sleY1731LckMac OBJECT IDENTIFIER ::= { sleY1731Oam 8 } sleY1731LckMacTable OBJECT-TYPE SYNTAX SEQUENCE OF SleY1731LckMacEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleY1731LckMac 1 } sleY1731LckMacEntry OBJECT-TYPE SYNTAX SleY1731LckMacEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731LckMacAddress } ::= { sleY1731LckMacTable 1 } SleY1731LckMacEntry ::= SEQUENCE { sleY1731LckMacAddress OCTET STRING } sleY1731LckMacAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the unicast MAC address to send LCK" ::= { sleY1731LckMacEntry 1 } sleY1731LckMacControl OBJECT IDENTIFIER ::= { sleY1731LckMac 2 } sleY1731LckMacControlRequest OBJECT-TYPE SYNTAX INTEGER { createY1731LckMac(1), deleteY1731LckMac(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731LckMacControl 1 } sleY1731LckMacControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731LckMacControl 2 } sleY1731LckMacControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731LckMacControl 3 } sleY1731LckMacControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731LckMacControl 4 } sleY1731LckMacControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731LckMacControl 5 } sleY1731LckMacControlMegIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the MEG's Index" ::= { sleY1731LckMacControl 6 } sleY1731LckMacControlMepIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "MEP Id" ::= { sleY1731LckMacControl 7 } sleY1731LckMacControlAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the unicast MAC address to send LCK When running deleteY1731LckMac, if this is zero-length, delete all unicast mac." ::= { sleY1731LckMacControl 8 } sleY1731LckMacNotification OBJECT IDENTIFIER ::= { sleY1731LckMac 3 } sleY1731LckMacCreated NOTIFICATION-TYPE OBJECTS { sleY1731LckMacControlRequest, sleY1731LckMacControlTimeStamp, sleY1731LckMacControlReqResult, sleY1731LckMacControlMegIndex, sleY1731LckMacControlMepIdentifier, sleY1731LckMacControlAddress } STATUS current DESCRIPTION "createY1731LckMac" ::= { sleY1731LckMacNotification 1 } sleY1731LckMacDeleted NOTIFICATION-TYPE OBJECTS { sleY1731LckMacControlRequest, sleY1731LckMacControlTimeStamp, sleY1731LckMacControlReqResult, sleY1731LckMacControlMegIndex, sleY1731LckMacControlMepIdentifier, sleY1731LckMacControlAddress } STATUS current DESCRIPTION "deleteY1731LckMac" ::= { sleY1731LckMacNotification 2 } sleY1731Rmep OBJECT IDENTIFIER ::= { sleY1731Oam 9 } sleY1731RmepTable OBJECT-TYPE SYNTAX SEQUENCE OF SleY1731RmepEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleY1731Rmep 1 } sleY1731RmepEntry OBJECT-TYPE SYNTAX SleY1731RmepEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731RmepIdentifier } ::= { sleY1731RmepTable 1 } SleY1731RmepEntry ::= SEQUENCE { sleY1731RmepIdentifier Integer32, sleY1731RmepState INTEGER, sleY1731RmepFailedOkTime TimeTicks, sleY1731RmepMacAddress OCTET STRING, sleY1731RmepIfIndex Integer32, sleY1731RmepRdi INTEGER, sleY1731RmepLoc INTEGER, sleY1731RmepReceiveTstCount Counter32, sleY1731RmepReceiveTstOutOfOrder Counter32, sleY1731RmepReceiveTstBitError Counter32, sleY1731RmepReceiveTstCrcError Counter32, sleY1731RmepReceiveTmTstCount Counter32, sleY1731RmepReceiveTmTstLostId Integer32, sleY1731RmepLmrFrameLossNearMin Integer32, sleY1731RmepLmrFrameLossNearMax Integer32, sleY1731RmepLmrFrameLossNearSum Integer32, sleY1731RmepLmrFrameLossFarMin Integer32, sleY1731RmepLmrFrameLossFarMax Integer32, sleY1731RmepLmrFrameLossFarSum Integer32, sleY1731RmepReceive1dmCount Counter32, sleY1731Rmep1dmFrameDelayMin Integer32, sleY1731Rmep1dmFrameDelayMax Integer32, sleY1731Rmep1dmFrameDelayAvg Integer32, sleY1731Rmep1dmFrameDelayVar Integer32, sleY1731RmepReceiveDmrCount Counter32, sleY1731RmepDmrFrameDelayMin Integer32, sleY1731RmepDmrFrameDelayMax Integer32, sleY1731RmepDmrFrameDelayAvg Integer32, sleY1731RmepDmrFrameDelayVar Integer32, sleY1731RmepLmrFrameLossNearRatio Integer32, sleY1731RmepLmrFrameLossNearAvgRatio Integer32, sleY1731RmepLmrFrameLossFarRatio Integer32, sleY1731RmepLmrFrameLossFarAvgRatio Integer32 } sleY1731RmepIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the remote MEP's Id" ::= { sleY1731RmepEntry 1 } sleY1731RmepState OBJECT-TYPE SYNTAX INTEGER { start(1), failed(2), ok(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the operational state of the remote MEP State machines" ::= { sleY1731RmepEntry 2 } sleY1731RmepFailedOkTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the time (SysUpTime) at which the Remote MEP state machine last entered either the RMEP_FAILED or RMEP_OK state." ::= { sleY1731RmepEntry 3 } sleY1731RmepMacAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the MAC address of the remote MEP" ::= { sleY1731RmepEntry 4 } sleY1731RmepIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the port number of the remote MEP" ::= { sleY1731RmepEntry 5 } sleY1731RmepRdi OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates State of the RDI bit in the last received CCM (true for RDI=1), or false if none has been received" ::= { sleY1731RmepEntry 6 } sleY1731RmepLoc OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates Loss-of-continuity" ::= { sleY1731RmepEntry 7 } sleY1731RmepReceiveTstCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of received TST frame" ::= { sleY1731RmepEntry 8 } sleY1731RmepReceiveTstOutOfOrder OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of received out-of-order TST frame" ::= { sleY1731RmepEntry 9 } sleY1731RmepReceiveTstBitError OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of received bit-error TST frame" ::= { sleY1731RmepEntry 10 } sleY1731RmepReceiveTstCrcError OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of received crc-error TST frame" ::= { sleY1731RmepEntry 11 } sleY1731RmepReceiveTmTstCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of received TST frame for the throughput-measurement" ::= { sleY1731RmepEntry 12 } sleY1731RmepReceiveTmTstLostId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the transaction identifier of first lost TST frame for the throughput-measurement" ::= { sleY1731RmepEntry 13 } sleY1731RmepLmrFrameLossNearMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the minimum of single-ended near-end frame loss" ::= { sleY1731RmepEntry 14 } sleY1731RmepLmrFrameLossNearMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the maximum of single-ended near-end frame loss" ::= { sleY1731RmepEntry 15 } sleY1731RmepLmrFrameLossNearSum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the sum of single-ended near-end frame loss" ::= { sleY1731RmepEntry 16 } sleY1731RmepLmrFrameLossFarMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the minimum of single-ended far-end frame loss" ::= { sleY1731RmepEntry 17 } sleY1731RmepLmrFrameLossFarMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the maximum of single-ended far-end frame loss" ::= { sleY1731RmepEntry 18 } sleY1731RmepLmrFrameLossFarSum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the sum of single-ended far-end frame loss" ::= { sleY1731RmepEntry 19 } sleY1731RmepReceive1dmCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of received 1DM frames for the frame delay measurement" ::= { sleY1731RmepEntry 20 } sleY1731Rmep1dmFrameDelayMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the minimum of one-way frame delay" ::= { sleY1731RmepEntry 21 } sleY1731Rmep1dmFrameDelayMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the maximum of one-way frame delay" ::= { sleY1731RmepEntry 22 } sleY1731Rmep1dmFrameDelayAvg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the average of one-way frame delay" ::= { sleY1731RmepEntry 23 } sleY1731Rmep1dmFrameDelayVar OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the variation of one-way frame delay" ::= { sleY1731RmepEntry 24 } sleY1731RmepReceiveDmrCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of received DMR frames for the frame delay measurement" ::= { sleY1731RmepEntry 25 } sleY1731RmepDmrFrameDelayMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the minimum of two-way frame delay" ::= { sleY1731RmepEntry 26 } sleY1731RmepDmrFrameDelayMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the maximum of two-way frame delay" ::= { sleY1731RmepEntry 27 } sleY1731RmepDmrFrameDelayAvg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the average of two-way frame delay" ::= { sleY1731RmepEntry 28 } sleY1731RmepDmrFrameDelayVar OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the variation of two-way frame delay" ::= { sleY1731RmepEntry 29 } sleY1731RmepLmrFrameLossNearRatio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ratio of single-ended near-end frame loss" ::= { sleY1731RmepEntry 30 } sleY1731RmepLmrFrameLossNearAvgRatio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the average ratio of single-ended near-end frame loss" ::= { sleY1731RmepEntry 31 } sleY1731RmepLmrFrameLossFarRatio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ratio of single-ended far-end frame loss" ::= { sleY1731RmepEntry 32 } sleY1731RmepLmrFrameLossFarAvgRatio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the average ratio of single-ended far-end frame loss" ::= { sleY1731RmepEntry 33 } sleY1731RmepControl OBJECT IDENTIFIER ::= { sleY1731Rmep 2 } sleY1731RmepControlRequest OBJECT-TYPE SYNTAX INTEGER { createY1731Rmep(1), deleteY1731Rmep(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731RmepControl 1 } sleY1731RMepControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731RmepControl 2 } sleY1731RmepControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731RmepControl 3 } sleY1731RmepControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731RmepControl 4 } sleY1731RmepControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731RmepControl 5 } sleY1731RmepControlIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Remote MEP Id" ::= { sleY1731RmepControl 6 } sleY1731RmepControlMegIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "A index of MEG table" ::= { sleY1731RmepControl 7 } sleY1731RmepControlIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Bridge Port Index whitch the MEP is attached" ::= { sleY1731RmepControl 8 } sleY1731RmepNotification OBJECT IDENTIFIER ::= { sleY1731Rmep 3 } sleY1731RmepCreated NOTIFICATION-TYPE OBJECTS { sleY1731RmepControlRequest, sleY1731RmepControlTimeStamp, sleY1731RmepControlReqResult, sleY1731RmepControlIdentifier, sleY1731RmepControlMegIndex, sleY1731RmepControlIfIndex } STATUS current DESCRIPTION "Description." ::= { sleY1731RmepNotification 1 } sleY1731RmepDeleted NOTIFICATION-TYPE OBJECTS { sleY1731RmepControlRequest, sleY1731RmepControlTimeStamp, sleY1731RmepControlReqResult, sleY1731RmepControlIdentifier, sleY1731RmepControlMegIndex, sleY1731RmepControlIfIndex } STATUS current DESCRIPTION "Description." ::= { sleY1731RmepNotification 2 } sleY1731LbrMcast OBJECT IDENTIFIER ::= { sleY1731Oam 10 } sleY1731LbrMcastTable OBJECT-TYPE SYNTAX SEQUENCE OF SleY1731LbrMcastEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleY1731LbrMcast 1 } sleY1731LbrMcastEntry OBJECT-TYPE SYNTAX SleY1731LbrMcastEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731LbrReceiveOrder } ::= { sleY1731LbrMcastTable 1 } SleY1731LbrMcastEntry ::= SEQUENCE { sleY1731LbrReceiveOrder Integer32, sleY1731LbrRemoteMacAddress OCTET STRING } sleY1731LbrReceiveOrder OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates an index to distinguish among multiple LBRs" ::= { sleY1731LbrMcastEntry 1 } sleY1731LbrRemoteMacAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the MAC address of the remote MEP" ::= { sleY1731LbrMcastEntry 2 } sleY1731LbrUcast OBJECT IDENTIFIER ::= { sleY1731Oam 11 } sleY1731LbrUcastTable OBJECT-TYPE SYNTAX SEQUENCE OF SleY1731LbrUcastEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleY1731LbrUcast 1 } sleY1731LbrUcastEntry OBJECT-TYPE SYNTAX SleY1731LbrUcastEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731LbrTransId } ::= { sleY1731LbrUcastTable 1 } SleY1731LbrUcastEntry ::= SEQUENCE { sleY1731LbrTransId Integer32, sleY1731LbrRoundTripTime Integer32 } sleY1731LbrTransId OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the transaction identifier of LBR message." ::= { sleY1731LbrUcastEntry 1 } sleY1731LbrRoundTripTime OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the round-trip time of LBR message." ::= { sleY1731LbrUcastEntry 2 } sleY1731Ltr OBJECT IDENTIFIER ::= { sleY1731Oam 12 } sleY1731LtrTable OBJECT-TYPE SYNTAX SEQUENCE OF SleY1731LtrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleY1731Ltr 1 } sleY1731LtrEntry OBJECT-TYPE SYNTAX SleY1731LtrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731LtrSeqNumber, sleY1731LtrReceiveOrder } ::= { sleY1731LtrTable 1 } SleY1731LtrEntry ::= SEQUENCE { sleY1731LtrSeqNumber Integer32, sleY1731LtrReceiveOrder Integer32, sleY1731LtrRoundTripTime Integer32, sleY1731LtrTtl Integer32, sleY1731LtrForwarded INTEGER, sleY1731LtrTerminalMep INTEGER, sleY1731LtrLastEgressIdentifier OCTET STRING, sleY1731LtrNextEgressIdentifier OCTET STRING, sleY1731LtrRelay INTEGER, sleY1731LtrIngress INTEGER, sleY1731LtrIngressMac OCTET STRING, sleY1731LtrIngressPort Integer32, sleY1731LtrEgress INTEGER, sleY1731LtrEgressMac OCTET STRING, sleY1731LtrEgressPort Integer32 } sleY1731LtrSeqNumber OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the LTM Transaction Identifier returned from a previous Transmit Linktrace Message command, indicating the LTM entry to which the LTR entries will be attached " ::= { sleY1731LtrEntry 1 } sleY1731LtrReceiveOrder OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates an index to distinguish among multiple LTRs with the same LTR Transaction Identifier field value" ::= { sleY1731LtrEntry 2 } sleY1731LtrRoundTripTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the round-trip time of LTR message." ::= { sleY1731LtrEntry 3 } sleY1731LtrTtl OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates TTL field value for a returned LTR." ::= { sleY1731LtrEntry 4 } sleY1731LtrForwarded OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if a LTM was forwarded by the responding MP, as returned in the 'FwdYes' flag of the flags field." ::= { sleY1731LtrEntry 5 } sleY1731LtrTerminalMep OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates a boolean value stating whether the forwarded LTM reached a MEP enclosing its MA, as returned in the Terminal MEP flag of the Flags field. " ::= { sleY1731LtrEntry 6 } sleY1731LtrLastEgressIdentifier OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the MEP Linktrace Initiator that originated, or the Linktrace Responder that forwarded, the LTM to which this LTR is the response" ::= { sleY1731LtrEntry 7 } sleY1731LtrNextEgressIdentifier OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the Linktrace Responder that transmitted this LTR, and can forward the LTM to the next hop." ::= { sleY1731LtrEntry 8 } sleY1731LtrRelay OBJECT-TYPE SYNTAX INTEGER { rlyHit(1), rlyFDB(2), rlyMPDB(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the value returned in the Ingress Action Field of the LTM" ::= { sleY1731LtrEntry 9 } sleY1731LtrIngress OBJECT-TYPE SYNTAX INTEGER { ingNoTlv(0), ingOK(1), ingDown(2), ingBlocked(3), ingVid(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the value returned in the Ingress Action Field of the LTM" ::= { sleY1731LtrEntry 10 } sleY1731LtrIngressMac OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates MAC address returned in the ingress MAC address field." ::= { sleY1731LtrEntry 11 } sleY1731LtrIngressPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates Ingress Port ID" ::= { sleY1731LtrEntry 12 } sleY1731LtrEgress OBJECT-TYPE SYNTAX INTEGER { egrNoTlv(0), egrOK(1), egrDown(2), egrBlocked(3), egrVid(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the value returned in the Egress Action Field of the LTM" ::= { sleY1731LtrEntry 13 } sleY1731LtrEgressMac OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates MAC address returned in the egress MAC address field." ::= { sleY1731LtrEntry 14 } sleY1731LtrEgressPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates Egress Port ID" ::= { sleY1731LtrEntry 15 } sleY1731ConfigError OBJECT IDENTIFIER ::= { sleY1731Oam 13 } sleY1731ConfigErrorTable OBJECT-TYPE SYNTAX SEQUENCE OF SleY1731ConfigErrorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleY1731ConfigError 1 } sleY1731ConfigErrorEntry OBJECT-TYPE SYNTAX SleY1731ConfigErrorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleY1731ConfigErrorVid, sleY1731ConfigErrorIfIndex } ::= { sleY1731ConfigErrorTable 1 } SleY1731ConfigErrorEntry ::= SEQUENCE { sleY1731ConfigErrorVid Integer32, sleY1731ConfigErrorIfIndex Integer32, sleY1731ConfigErrorType BITS } sleY1731ConfigErrorVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Configuration Error VLAN Identifier" ::= { sleY1731ConfigErrorEntry 1 } sleY1731ConfigErrorIfIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Configuration Error Port Number" ::= { sleY1731ConfigErrorEntry 2 } sleY1731ConfigErrorType OBJECT-TYPE SYNTAX BITS { y1731leak(0), conflictingVids(1), excessiveLevels(2), overlappedLevels(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Configuration Error Type" ::= { sleY1731ConfigErrorEntry 3 } sleY1731MipCcdb OBJECT IDENTIFIER ::= { sleY1731Oam 14 } sleY1731MipCcdbTable OBJECT-TYPE SYNTAX SEQUENCE OF SleY1731MipCcdbEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleY1731MipCcdb 1 } sleY1731MipCcdbEntry OBJECT-TYPE SYNTAX SleY1731MipCcdbEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleY1731MipCcdbIndex } ::= { sleY1731MipCcdbTable 1 } SleY1731MipCcdbEntry ::= SEQUENCE { sleY1731MipCcdbIndex Integer32, sleY1731MipCcdbVlanId Integer32, sleY1731MipCcdbMacAddr OCTET STRING, sleY1731MipCcdbPort Integer32, sleY1731MipCcdbKeepTime TimeTicks } sleY1731MipCcdbIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the MIP CCDB's Index" ::= { sleY1731MipCcdbEntry 1 } sleY1731MipCcdbVlanId OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "VLAN Id" ::= { sleY1731MipCcdbEntry 2 } sleY1731MipCcdbMacAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates MAC address of the remote MEP" ::= { sleY1731MipCcdbEntry 3 } sleY1731MipCcdbPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Port number that the CCM output" ::= { sleY1731MipCcdbEntry 4 } sleY1731MipCcdbKeepTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates an up-date time of a entry" ::= { sleY1731MipCcdbEntry 5 } sleY1731UplinkRedundancy OBJECT IDENTIFIER ::= { sleY1731Oam 15 } sleY1731URTable OBJECT-TYPE SYNTAX SEQUENCE OF SleY1731UREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Y1731 Uplink-redundancy information table." ::= { sleY1731UplinkRedundancy 1 } sleY1731UREntry OBJECT-TYPE SYNTAX SleY1731UREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "key: sleY1731URMegIndex" INDEX { sleY1731URMegIndex } ::= { sleY1731URTable 1 } SleY1731UREntry ::= SEQUENCE { sleY1731URMegIndex INTEGER, sleY1731URMegName OCTET STRING, sleY1731URDedicatedVlan INTEGER, sleY1731UREnableStatus INTEGER, sleY1731URConnectivityCheckMeg OCTET STRING, sleY1731URPrimaryMepId INTEGER, sleY1731URSecondaryMepId INTEGER, sleY1731URControlVlan INTEGER, sleY1731URNodeConf INTEGER, sleY1731URNodeConfPortNum INTEGER, sleY1731URNodeConfPortStatus INTEGER, sleY1731URNonRevertive INTEGER, sleY1731URTrustMemberCount INTEGER, sleY1731URWaitToRestore INTEGER, sleY1731URForceSwitch INTEGER, sleY1731URSFCondition INTEGER, sleY1731URTrafficVlan OCTET STRING, sleY1731URState INTEGER, sleY1731URManualSwitch INTEGER } sleY1731URMegIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The MEG index." ::= { sleY1731UREntry 1 } sleY1731URMegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The MEG name." ::= { sleY1731UREntry 2 } sleY1731URDedicatedVlan OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates R-APS node to use dedicated-VLAN disable : all VLAN enable : one VLAN" ::= { sleY1731UREntry 3 } sleY1731UREnableStatus OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Uplink-redundancy feature 0 : disable 1 : enable" ::= { sleY1731UREntry 4 } sleY1731URConnectivityCheckMeg OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the connectivity check - MEG name." ::= { sleY1731UREntry 5 } sleY1731URPrimaryMepId OBJECT-TYPE SYNTAX INTEGER (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the connectivity check - primary MEP's ID" ::= { sleY1731UREntry 6 } sleY1731URSecondaryMepId OBJECT-TYPE SYNTAX INTEGER (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the connectivity check - secondary MEP's ID" ::= { sleY1731UREntry 7 } sleY1731URControlVlan OBJECT-TYPE SYNTAX INTEGER (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the control VLAN" ::= { sleY1731UREntry 8 } sleY1731URNodeConf OBJECT-TYPE SYNTAX INTEGER { none(0), master(1), slave(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the (master/slave) node of the redundancy" ::= { sleY1731UREntry 9 } sleY1731URNodeConfPortNum OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The port number" ::= { sleY1731UREntry 10 } sleY1731URNodeConfPortStatus OBJECT-TYPE SYNTAX INTEGER { none(0), disabled(1), forwarding(2), blocking(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The uplink port status 0: none 1: disabled 2: forwarding 3: blocking" ::= { sleY1731UREntry 11 } sleY1731URNonRevertive OBJECT-TYPE SYNTAX INTEGER { false(0), ture(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The non-revertive mode" ::= { sleY1731UREntry 12 } sleY1731URTrustMemberCount OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the trust LOC count at link-aggregation port" ::= { sleY1731UREntry 13 } sleY1731URWaitToRestore OBJECT-TYPE SYNTAX INTEGER (5..720) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the wait-to-restore time ( 5 - 720 )" ::= { sleY1731UREntry 14 } sleY1731URForceSwitch OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The forced-switch of uplink port " ::= { sleY1731UREntry 15 } sleY1731URSFCondition OBJECT-TYPE SYNTAX INTEGER { loc(0), locRdi(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The sf condition " ::= { sleY1731UREntry 16 } sleY1731URTrafficVlan OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The Traffic vlan. " ::= { sleY1731UREntry 17 } sleY1731URState OBJECT-TYPE SYNTAX INTEGER { unReady(0), ready(1), active(2), standby(3), preActive(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The uplink redundancy node state none(0) unReady(1) ready(2) active(3) standby(4) preActive(5)" ::= { sleY1731UREntry 18 } sleY1731URManualSwitch OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The manual-switch of uplink port " ::= { sleY1731UREntry 19 } sleY1731URControl OBJECT IDENTIFIER ::= { sleY1731UplinkRedundancy 2 } sleY1731URControlRequest OBJECT-TYPE SYNTAX INTEGER { setDedicatedVlan(1), setEnableStatus(2), setCCPrimaryMepId(3), clearCCPrimaryMepId(4), setCCSecondaryMepId(5), clearCCSecondaryMepId(6), setControlVlan(7), clearControlVlan(8), setNodeConfiguration(9), clearNodeConfiguration(10), setNonRevertive(11), setTrustMemberCount(12), clearTrustMemberCount(13), setWaitToRestore(14), clearWaitToRestore(15), setForceSwitch(16), setManualSwitch(17), setSFCondition(18), setTrafficVlan(19), clearTrafficVlan(20) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute identifies the control commands. updateAlarmList: the NE updates entries of alarms in the sleAlarmListTable after having changed alarm severities of alarms (due to change profile pointers in managed entities or after modification of alarm severities in profiles). This command should be applied once after having finisled modifications of severties. modifyAlarmSeverity: modifies the severity of an alarm in specific profile. createAlarmSeverityProfile: creates a new profile with default severities. The severities then have to be modified with command changeAlarmSeverity. deleteAlarmSeverityProfile: deletes a profile. Profile 1 is not allowed to be deleted. Notifications : none " ::= { sleY1731URControl 1 } sleY1731URControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "The status of a control request. " ::= { sleY1731URControl 2 } sleY1731URControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION " The maximum wait time for the manager for command ending. For long running commands. The manager reads this value from the DSLAM. " ::= { sleY1731URControl 3 } sleY1731URControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION " The time stamp of the last command (end of command). " ::= { sleY1731URControl 4 } sleY1731URControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "The result of the last user command. " ::= { sleY1731URControl 5 } sleY1731URControlMegIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The MEG index." ::= { sleY1731URControl 6 } sleY1731URControlMegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "The MEG name." ::= { sleY1731URControl 7 } sleY1731URControlDedicatedVlan OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates R-APS node to use dedicated-VLAN disable : all VLAN enable : one VLAN" ::= { sleY1731URControl 8 } sleY1731URControlEnableStatus OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Uplink-redundancy feature 0 : disable 1 : enable" ::= { sleY1731URControl 9 } sleY1731URControlConnectivityCheckMeg OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the connectivity check - MEG name." ::= { sleY1731URControl 10 } sleY1731URControlPrimaryMepId OBJECT-TYPE SYNTAX INTEGER (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the connectivity check - primary MEP's ID" ::= { sleY1731URControl 11 } sleY1731URControlSecondaryMepId OBJECT-TYPE SYNTAX INTEGER (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the connectivity check - secondary MEP's ID" ::= { sleY1731URControl 12 } sleY1731URControlControlVlan OBJECT-TYPE SYNTAX INTEGER (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the control VLAN" ::= { sleY1731URControl 13 } sleY1731URControlNodeConf OBJECT-TYPE SYNTAX INTEGER { none(0), master(1), slave(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the (master/slave) node of the redundancy" ::= { sleY1731URControl 14 } sleY1731URControlNodeConfPortNum OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The port number" ::= { sleY1731URControl 15 } sleY1731URControlNonRevertive OBJECT-TYPE SYNTAX INTEGER { false(0), ture(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The non-revertive mode" ::= { sleY1731URControl 16 } sleY1731URControlTrustMemberCount OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the trust LOC count at link-aggregation port" ::= { sleY1731URControl 17 } sleY1731URControlWaitToRestore OBJECT-TYPE SYNTAX INTEGER (5..720) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the wait-to-restore time ( 5 - 720 )" ::= { sleY1731URControl 18 } sleY1731URControlForceSwitch OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The forced-switch of uplink port" ::= { sleY1731URControl 19 } sleY1731URControlSFCondition OBJECT-TYPE SYNTAX INTEGER { loc(0), locRdi(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The sf condition" ::= { sleY1731URControl 20 } sleY1731URControlTrafficVlan OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "The Traffic vlan" ::= { sleY1731URControl 21 } sleY1731URControlManualSwitch OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The manual-switch of uplink port" ::= { sleY1731URControl 22 } sleY1731URNotification OBJECT IDENTIFIER ::= { sleY1731UplinkRedundancy 3 } sleY1731URDedicatedVlanChanged NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlDedicatedVlan } STATUS current DESCRIPTION "setY1731URDedicatedVlan" ::= { sleY1731URNotification 1 } sleY1731UREnableStatusChanged NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName, sleY1731URControlEnableStatus } STATUS current DESCRIPTION "setY1731UREnableStatus" ::= { sleY1731URNotification 2 } sleY1731URCCPrimaryMepIdChanged NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName, sleY1731URControlConnectivityCheckMeg, sleY1731URControlPrimaryMepId } STATUS current DESCRIPTION "setY1731URCCPrimaryMepId" ::= { sleY1731URNotification 3 } sleY1731URCCPrimaryMepIdCleared NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName } STATUS current DESCRIPTION "delY1731URCCPrimaryMepId" ::= { sleY1731URNotification 4 } sleY1731URCCSecondaryMepIdChanged NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName, sleY1731URControlConnectivityCheckMeg, sleY1731URControlSecondaryMepId } STATUS current DESCRIPTION "setY1731URCCSecondaryMepId" ::= { sleY1731URNotification 5 } sleY1731URCCSecondaryMepIdCleared NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName } STATUS current DESCRIPTION "delY1731URCCSecondaryMepId" ::= { sleY1731URNotification 6 } sleY1731URControlVlanChanged NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName, sleY1731URControlControlVlan } STATUS current DESCRIPTION "setY1731URControlVlan" ::= { sleY1731URNotification 7 } sleY1731URControlVlanCleared NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName } STATUS current DESCRIPTION "delY1731URControlVlan" ::= { sleY1731URNotification 8 } sleY1731URNodeConfChanged NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName, sleY1731URControlNodeConf, sleY1731URControlNodeConfPortNum } STATUS current DESCRIPTION "setY1731URNodeConf" ::= { sleY1731URNotification 9 } sleY1731URNodeConfCleared NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName, sleY1731URControlNodeConf } STATUS current DESCRIPTION "delY1731URNodeConf" ::= { sleY1731URNotification 10 } sleY1731URNonRevertiveChanged NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName, sleY1731URControlNonRevertive } STATUS current DESCRIPTION "setY1731URNonRevertive" ::= { sleY1731URNotification 11 } sleY1731URTrustMemberCountChanged NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName, sleY1731URControlTrustMemberCount } STATUS current DESCRIPTION "setY1731URTrustMemberCount" ::= { sleY1731URNotification 12 } sleY1731URTrustMemberCountCleared NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName } STATUS current DESCRIPTION "delY1731URTrustMemberCount" ::= { sleY1731URNotification 13 } sleY1731URWaitToRestoreChanged NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName, sleY1731URControlWaitToRestore } STATUS current DESCRIPTION "setY1731URWaitToRestore" ::= { sleY1731URNotification 14 } sleY1731URWaitToRestoreCleared NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName } STATUS current DESCRIPTION "delY1731URWaitToRestore" ::= { sleY1731URNotification 15 } sleY1731URForceSwitchChanged NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName, sleY1731URControlForceSwitch } STATUS current DESCRIPTION "setForceSwitch" ::= { sleY1731URNotification 16 } sleY1731URManualSwitchChanged NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName, sleY1731URControlManualSwitch } STATUS current DESCRIPTION "setManualSwitch" ::= { sleY1731URNotification 17 } sleY1731URSFConditionChanged NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName } STATUS current DESCRIPTION "setSFCondition" ::= { sleY1731URNotification 18 } sleY1731URTrafficVlanChanged NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName, sleY1731URControlTrafficVlan } STATUS current DESCRIPTION "setTrafficVlan." ::= { sleY1731URNotification 19 } sleY1731URTrafficVlanCleared NOTIFICATION-TYPE OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex } STATUS current DESCRIPTION "clearTrafficVlan." ::= { sleY1731URNotification 20 } sleY1731LocRefMep OBJECT IDENTIFIER ::= { sleY1731Oam 16 } sleY1731LocRefMepTable OBJECT-TYPE SYNTAX SEQUENCE OF SleY1731LocRefMepEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleY1731LocRefMep 1 } sleY1731LocRefMepEntry OBJECT-TYPE SYNTAX SleY1731LocRefMepEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731CcMacAddress } ::= { sleY1731LocRefMepTable 1 } SleY1731LocRefMepEntry ::= SEQUENCE { sleY1731LRMepIndex Integer32, sleY1731LRMepDMegIndex Integer32, sleY1731LRMepDMepIdentifier Integer32, sleY1731LRMepDRmepIdentifier Integer32 } sleY1731LRMepIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the index of the LOC reference MEP." ::= { sleY1731LocRefMepEntry 1 } sleY1731LRMepDMegIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the MEG's Index of Down MEP" ::= { sleY1731LocRefMepEntry 2 } sleY1731LRMepDMepIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the identifier of Down MEP." ::= { sleY1731LocRefMepEntry 3 } sleY1731LRMepDRmepIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the identifier of Remote MEP." ::= { sleY1731LocRefMepEntry 4 } sleY1731LocRefMepControl OBJECT IDENTIFIER ::= { sleY1731LocRefMep 2 } sleY1731LRMepControlRequest OBJECT-TYPE SYNTAX INTEGER { createY1731LocRefMep(1), deleteY1731LocRefMep(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731LocRefMepControl 1 } sleY1731LRMepControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731LocRefMepControl 2 } sleY1731LRMepControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleY1731LocRefMepControl 3 } sleY1731LRMepControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleY1731LocRefMepControl 4 } sleY1731LRMepControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION "Result of the last command." ::= { sleY1731LocRefMepControl 5 } sleY1731LRMepControlMegIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the MEG's Index of Up MEP." ::= { sleY1731LocRefMepControl 6 } sleY1731LRMepControlMepIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the identifier of Up MEP." ::= { sleY1731LocRefMepControl 7 } sleY1731LRMepControlRmepIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the identifier of RMEP id of Up MEP." ::= { sleY1731LocRefMepControl 8 } sleY1731LRMepControlDMegIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the MEG's Index of Down MEP." ::= { sleY1731LocRefMepControl 9 } sleY1731LRMepControlDMepIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the identifier of Down MEP." ::= { sleY1731LocRefMepControl 10 } sleY1731LRMepControlDRmepIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the identifier of RMEP id of Down MEP." ::= { sleY1731LocRefMepControl 11 } sleY1731LocRefMepNotification OBJECT IDENTIFIER ::= { sleY1731LocRefMep 3 } sleY1731LRMepCreated NOTIFICATION-TYPE OBJECTS { sleY1731LRMepControlRequest, sleY1731LRMepControlTimeStamp, sleY1731LRMepControlReqResult, sleY1731LRMepControlMegIndex, sleY1731LRMepControlMepIdentifier, sleY1731LRMepControlRmepIdentifier, sleY1731LRMepControlDMegIndex, sleY1731LRMepControlDMepIdentifier, sleY1731LRMepControlDRmepIdentifier } STATUS current DESCRIPTION "createY1731LocRefMep" ::= { sleY1731LocRefMepNotification 1 } sleY1731LRMEPDeleted NOTIFICATION-TYPE OBJECTS { sleY1731LRMepControlRequest, sleY1731LRMepControlTimeStamp, sleY1731LRMepControlReqResult, sleY1731LRMepControlMegIndex, sleY1731LRMepControlMepIdentifier, sleY1731LRMepControlRmepIdentifier, sleY1731LRMepControlDMegIndex, sleY1731LRMepControlDMepIdentifier, sleY1731LRMepControlDRmepIdentifier } STATUS current DESCRIPTION "deleteY1731LocRefMep" ::= { sleY1731LocRefMepNotification 3 } sleCfmOam OBJECT IDENTIFIER ::= { sleFaultMgmt 13 } sleCfmBase OBJECT IDENTIFIER ::= { sleCfmOam 1 } sleCfmBaseGroup OBJECT IDENTIFIER ::= { sleCfmBase 1 } sleCfmEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables/Ddisables IEEE 802.1ag CFM OAM function" ::= { sleCfmBaseGroup 1 } sleCfmLtrCacheHoldTime OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the time that cache entries will be retained" ::= { sleCfmBaseGroup 2 } sleCfmLtrCacheSize OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of entries in the traceroute cache" ::= { sleCfmBaseGroup 3 } sleCfmSnmpServerTraps OBJECT-TYPE SYNTAX BITS { rdiccm(0), macstatus(1), remoteccm(2), errorccm(3), xconccm(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the SNMP traps" ::= { sleCfmBaseGroup 4 } sleCfmXcheckStartDelay OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the delay before the cross-check is started" ::= { sleCfmBaseGroup 5 } sleCfmBaseControl OBJECT IDENTIFIER ::= { sleCfmBase 2 } sleCfmBaseControlRequest OBJECT-TYPE SYNTAX INTEGER { setCfmEnable(1), setCfmLtrCacheProfile(2), setCfmSnmpProfile(3), setCfmXcheckProfile(4), destroyMipCcdb(5), destroyLtrCache(6), createCfmTrunkPort(7), deleteCfmTrunkPort(8) } MAX-ACCESS read-write STATUS current DESCRIPTION " This attribute identifies the control commands. updateAlarmList: the NE updates entries of alarms in the sleAlarmListTable after having changed alarm severities of alarms (due to change profile pointers in managed entities or after modification of alarm severities in profiles). This command should be applied once after having finisled modifications of severties. modifyAlarmSeverity: modifies the severity of an alarm in specific profile. createAlarmSeverityProfile: creates a new profile with default severities. The severities then have to be modified with command changeAlarmSeverity. deleteAlarmSeverityProfile: deletes a profile. Profile 1 is not allowed to be deleted. Notifications : none " ::= { sleCfmBaseControl 1 } sleCfmBaseControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION " The status of a control request. " ::= { sleCfmBaseControl 2 } sleCfmBaseControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION " The maximum wait time for the manager for command ending. For long running commands. The manager reads this value from the DSLAM. " ::= { sleCfmBaseControl 3 } sleCfmBaseControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION " The time stamp of the last command (end of command). " ::= { sleCfmBaseControl 4 } sleCfmBaseControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION " The result of the last user command. " ::= { sleCfmBaseControl 5 } sleCfmBaseControlEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Ddisables IEEE 802.1ag CFM OAM function" ::= { sleCfmBaseControl 6 } sleCfmBaseControlLtrCacheHoldTime OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the time that cache entries will be retained" ::= { sleCfmBaseControl 7 } sleCfmBaseControlLtrCacheSize OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the number of entries in the traceroute cache" ::= { sleCfmBaseControl 8 } sleCfmBaseControlSnmpServerTraps OBJECT-TYPE SYNTAX BITS { ridccm(0), macstatus(1), remoteccm(2), errorccm(3), xconccm(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the SNMP traps" ::= { sleCfmBaseControl 9 } sleCfmBaseControlXcheckStartDelay OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the delay before the cross-check is started" ::= { sleCfmBaseControl 10 } sleCfmBaseControlTrunkIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Trunk Port Index" ::= { sleCfmBaseControl 11 } sleCfmBaseControlTrunkMdName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "trunk port md name." ::= { sleCfmBaseControl 12 } sleCfmBaseControlTrunkMaVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the MA's VID" ::= { sleCfmBaseControl 13 } sleCfmBaseNotification OBJECT IDENTIFIER ::= { sleCfmBase 3 } sleCfmEnableChanged NOTIFICATION-TYPE OBJECTS { sleCfmBaseControlStatus, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult, sleCfmBaseControlEnable } STATUS current DESCRIPTION "setCfmEnable" ::= { sleCfmBaseNotification 1 } sleCfmLtrCacheProfileChanged NOTIFICATION-TYPE OBJECTS { sleCfmBaseControlStatus, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult, sleCfmBaseControlLtrCacheHoldTime, sleCfmBaseControlLtrCacheSize } STATUS current DESCRIPTION "setCfmLtrCacheProfile" ::= { sleCfmBaseNotification 2 } sleCfmSnmpServerTrapsChanged NOTIFICATION-TYPE OBJECTS { sleCfmBaseControlStatus, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult, sleCfmBaseControlSnmpServerTraps } STATUS current DESCRIPTION "setCfmSnmpProfile" ::= { sleCfmBaseNotification 3 } sleCfmXcheckStartDelayChanged NOTIFICATION-TYPE OBJECTS { sleCfmBaseControlStatus, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult, sleCfmBaseControlXcheckStartDelay } STATUS current DESCRIPTION "setCfmXcheckProfile" ::= { sleCfmBaseNotification 4 } sleCfmMipCcdbDestroyed NOTIFICATION-TYPE OBJECTS { sleCfmBaseControlRequest, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult } STATUS current DESCRIPTION "destroyMipCcdb" ::= { sleCfmBaseNotification 5 } sleCfmLtrCacheDestroyed NOTIFICATION-TYPE OBJECTS { sleCfmBaseControlRequest, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult } STATUS current DESCRIPTION "destroyLtrCache" ::= { sleCfmBaseNotification 6 } sleCfmTrunkPortCreated NOTIFICATION-TYPE OBJECTS { sleCfmBaseControlStatus, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult, sleCfmBaseControlTrunkIndex, sleCfmBaseControlTrunkMdName, sleCfmBaseControlTrunkMaVid } STATUS current DESCRIPTION "createCfmTrunkPort" ::= { sleCfmBaseNotification 7 } sleCfmTrunkPortDeleted NOTIFICATION-TYPE OBJECTS { sleCfmBaseControlStatus, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult, sleCfmBaseControlTrunkIndex } STATUS current DESCRIPTION "deleteCfmTrunkPort" ::= { sleCfmBaseNotification 8 } sleCfmTrunkTable OBJECT-TYPE SYNTAX SEQUENCE OF SleCfmTrunkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleCfmBase 4 } sleCfmTrunkEntry OBJECT-TYPE SYNTAX SleCfmTrunkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleCfmTrunkIndex } ::= { sleCfmTrunkTable 1 } SleCfmTrunkEntry ::= SEQUENCE { sleCfmTrunkIndex INTEGER, sleCfmTrunkMdName OCTET STRING, sleCfmTrunkMaVid INTEGER } sleCfmTrunkIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "trunk port index." ::= { sleCfmTrunkEntry 1 } sleCfmTrunkMdName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..12)) MAX-ACCESS read-only STATUS current DESCRIPTION "trunk port md name." ::= { sleCfmTrunkEntry 2 } sleCfmTrunkMaVid OBJECT-TYPE SYNTAX INTEGER (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the MA's VID" ::= { sleCfmTrunkEntry 3 } sleCfmMd OBJECT IDENTIFIER ::= { sleCfmOam 2 } sleCfmMdTable OBJECT-TYPE SYNTAX SEQUENCE OF SleCfmMdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleCfmMd 1 } sleCfmMdEntry OBJECT-TYPE SYNTAX SleCfmMdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleCfmMdIndex } ::= { sleCfmMdTable 1 } SleCfmMdEntry ::= SEQUENCE { sleCfmMdIndex Integer32, sleCfmMdName OCTET STRING, sleCfmMdLevel Integer32, sleCfmMdMepEnable INTEGER, sleCfmMdCcEnable INTEGER, sleCfmMdCcInterval Integer32, sleCfmMdCcPriority Integer32, sleCfmMdCcLossThreshold Integer32, sleCfmMdCcHoldTime Integer32, sleCfmMdFaultPriority INTEGER, sleCfmMdFaultKeepTime Integer32, sleCfmMdFaultClearTime Integer32, sleCfmMdXcheckEnable INTEGER } sleCfmMdIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the MD's Index" ::= { sleCfmMdEntry 1 } sleCfmMdName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..12)) MAX-ACCESS read-only STATUS current DESCRIPTION "The MD's name" ::= { sleCfmMdEntry 2 } sleCfmMdLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the MD's level" ::= { sleCfmMdEntry 3 } sleCfmMdMepEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables/Disables CFM OAM for MEPs" ::= { sleCfmMdEntry 4 } sleCfmMdCcEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables/Disables MEPs to send Continuity Check messages" ::= { sleCfmMdEntry 5 } sleCfmMdCcInterval OBJECT-TYPE SYNTAX Integer32 (2..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the interval between CCM transmissions" ::= { sleCfmMdEntry 6 } sleCfmMdCcPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the CCM Priority" ::= { sleCfmMdEntry 7 } sleCfmMdCcLossThreshold OBJECT-TYPE SYNTAX Integer32 (2..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the minimum number of CCMs that can be missed before declaring that a MEP is down" ::= { sleCfmMdEntry 8 } sleCfmMdCcHoldTime OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the time that data of a missing MEP is kept" ::= { sleCfmMdEntry 9 } sleCfmMdFaultPriority OBJECT-TYPE SYNTAX INTEGER { rdiccm(1), macstatus(2), remoteccm(3), errorccm(4), xconccm(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the lowest priority for fault alarm" ::= { sleCfmMdEntry 10 } sleCfmMdFaultKeepTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the keep time for the fault alarm" ::= { sleCfmMdEntry 11 } sleCfmMdFaultClearTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the clear time for the fault alarm" ::= { sleCfmMdEntry 12 } sleCfmMdXcheckEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables/Disables CFM cross-check for a specific MEG" ::= { sleCfmMdEntry 13 } sleCfmMdControl OBJECT IDENTIFIER ::= { sleCfmMd 2 } sleCfmMdControlRequest OBJECT-TYPE SYNTAX INTEGER { createCfmMd(1), deleteCfmMd(2), setCfmMdMepEnable(3), setCfmMdCcEnable(4), setCfmMdCcProfile(5), setCfmMdFaultProfile(6), setCfmMdXcheckEnable(7), destroyCfmMdError(8), destroyCfmMdRmep(9) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleCfmMdControl 1 } sleCfmMdControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleCfmMdControl 2 } sleCfmMdControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleCfmMdControl 3 } sleCfmMdControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleCfmMdControl 4 } sleCfmMdControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleCfmMdControl 5 } sleCfmMdControlIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the MD's Index" ::= { sleCfmMdControl 6 } sleCfmMdControlName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "The MD's name" ::= { sleCfmMdControl 7 } sleCfmMdControlLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the MD's level" ::= { sleCfmMdControl 8 } sleCfmMdControlMepEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables CFM OAM for MEPs" ::= { sleCfmMdControl 9 } sleCfmMdControlCcEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables MEPs to send Continuity Check messages" ::= { sleCfmMdControl 10 } sleCfmMdControlCcInterval OBJECT-TYPE SYNTAX Integer32 (2..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the interval between CCM transmissions" ::= { sleCfmMdControl 11 } sleCfmMdControlCcPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the CCM Priority" ::= { sleCfmMdControl 12 } sleCfmMdControlCcLossThreshold OBJECT-TYPE SYNTAX Integer32 (2..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the minimum number of CCMs that can be missed before declaring that a MEP is down" ::= { sleCfmMdControl 13 } sleCfmMdControlCcHoldTime OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the time that data of a missing MEP is kept" ::= { sleCfmMdControl 14 } sleCfmMdControlFaultPriority OBJECT-TYPE SYNTAX INTEGER { rdiccm(1), macstatus(2), remoteccm(3), errorccm(4), xconccm(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the lowest priority for fault alarm" ::= { sleCfmMdControl 15 } sleCfmMdControlFaultKeepTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the keep time for the fault alarm" ::= { sleCfmMdControl 16 } sleCfmMdControlFaultClearTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the clear time for the fault alarm" ::= { sleCfmMdControl 17 } sleCfmMdControlXcheckEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables CFM cross-check for a specific MEG" ::= { sleCfmMdControl 18 } sleCfmMdNotification OBJECT IDENTIFIER ::= { sleCfmMd 3 } sleCfmMdCreated NOTIFICATION-TYPE OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlName, sleCfmMdControlLevel } STATUS current DESCRIPTION "createCfmMd" ::= { sleCfmMdNotification 1 } sleCfmMdDeleted NOTIFICATION-TYPE OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlName } STATUS current DESCRIPTION "deleteCfmMd" ::= { sleCfmMdNotification 2 } sleCfmMdMepEnableChanged NOTIFICATION-TYPE OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex, sleCfmMdControlMepEnable } STATUS current DESCRIPTION "setCfmMepEnable" ::= { sleCfmMdNotification 3 } sleCfmMdCcEnableChanged NOTIFICATION-TYPE OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex, sleCfmMdControlCcEnable } STATUS current DESCRIPTION "setCfmMdCcEnable" ::= { sleCfmMdNotification 4 } sleCfmMdCcProfileChanged NOTIFICATION-TYPE OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex, sleCfmMdControlCcInterval, sleCfmMdControlCcPriority, sleCfmMdControlCcLossThreshold, sleCfmMdControlCcHoldTime } STATUS current DESCRIPTION "setCfmMdCcProfile" ::= { sleCfmMdNotification 5 } sleCfmMdFaultProfileChanged NOTIFICATION-TYPE OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex, sleCfmMdControlFaultPriority, sleCfmMdControlFaultKeepTime, sleCfmMdControlFaultClearTime } STATUS current DESCRIPTION "setCfmMdFaultProfile" ::= { sleCfmMdNotification 6 } sleCfmMdXcheckEnableChanged NOTIFICATION-TYPE OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex, sleCfmMdControlXcheckEnable } STATUS current DESCRIPTION "setCfmMdXcheckEnable" ::= { sleCfmMdNotification 7 } sleCfmMdErrorDestoryed NOTIFICATION-TYPE OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex } STATUS current DESCRIPTION "destroyCfmMdError" ::= { sleCfmMdNotification 8 } sleCfmMdRmepDestoryed NOTIFICATION-TYPE OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex } STATUS current DESCRIPTION "destroyCfmMdRmep" ::= { sleCfmMdNotification 9 } sleCfmMa OBJECT IDENTIFIER ::= { sleCfmOam 3 } sleCfmMaTable OBJECT-TYPE SYNTAX SEQUENCE OF SleCfmMaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleCfmMa 1 } sleCfmMaEntry OBJECT-TYPE SYNTAX SleCfmMaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleCfmMdIndex, sleCfmMaIndex } ::= { sleCfmMaTable 1 } SleCfmMaEntry ::= SEQUENCE { sleCfmMaIndex Integer32, sleCfmMaName OCTET STRING, sleCfmMaVid Integer32, sleCfmMaMepEnable INTEGER, sleCfmMaCcEnable INTEGER, sleCfmMaCcInterval Integer32, sleCfmMaCcPriority Integer32, sleCfmMaCcLossThreshold Integer32, sleCfmMaCcFaultPriority INTEGER, sleCfmMaCcFaultKeepTime Integer32, sleCfmMaCcFaultClearTime Integer32, sleCfmMaXcheckEnable INTEGER } sleCfmMaIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the MA's Index" ::= { sleCfmMaEntry 1 } sleCfmMaName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..12)) MAX-ACCESS read-only STATUS current DESCRIPTION "The MA's name" ::= { sleCfmMaEntry 2 } sleCfmMaVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the MA's VID" ::= { sleCfmMaEntry 3 } sleCfmMaMepEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables/Disables CFM OAM for MEPs" ::= { sleCfmMaEntry 4 } sleCfmMaCcEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables/Disables MEPs to send Continuity Check messages" ::= { sleCfmMaEntry 5 } sleCfmMaCcInterval OBJECT-TYPE SYNTAX Integer32 (2..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the interval between CCM transmissions" ::= { sleCfmMaEntry 6 } sleCfmMaCcPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the CCM Priority" ::= { sleCfmMaEntry 7 } sleCfmMaCcLossThreshold OBJECT-TYPE SYNTAX Integer32 (2..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the minimum number of CCMs that can be missed before declaring that a MEP is down" ::= { sleCfmMaEntry 8 } sleCfmMaCcFaultPriority OBJECT-TYPE SYNTAX INTEGER { rdiccm(1), macstatus(2), remoteccm(3), errorccm(4), xconccm(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the lowest priority for fault alarm" ::= { sleCfmMaEntry 9 } sleCfmMaCcFaultKeepTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the keep time for the fault alarm" ::= { sleCfmMaEntry 10 } sleCfmMaCcFaultClearTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the clear time for the fault alarm" ::= { sleCfmMaEntry 11 } sleCfmMaXcheckEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables/Disables CFM cross-check for a specific MEG" ::= { sleCfmMaEntry 12 } sleCfmMaControl OBJECT IDENTIFIER ::= { sleCfmMa 2 } sleCfmMaControlRequest OBJECT-TYPE SYNTAX INTEGER { createCfmMa(1), deleteCfmMa(2), setCfmMaMepEnable(3), setCfmMaCcEnable(4), setCfmMaCcProfile(5), setCfmMaFaultProfile(6), setCfmMaXcheckEnable(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleCfmMaControl 1 } sleCfmMaControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleCfmMaControl 2 } sleCfmMaControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleCfmMaControl 3 } sleCfmMaControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleCfmMaControl 4 } sleCfmMaControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleCfmMaControl 5 } sleCfmMaControlIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the MA's Index" ::= { sleCfmMaControl 6 } sleCfmMaControlName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "The MA's name." ::= { sleCfmMaControl 7 } sleCfmMaControlVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the MA's VID" ::= { sleCfmMaControl 8 } sleCfmMaControlMdIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the MD's Index" ::= { sleCfmMaControl 9 } sleCfmMaControlMepEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables CFM OAM for MEPs" ::= { sleCfmMaControl 10 } sleCfmMaControlCcEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables MEPs to send Continuity Check messages" ::= { sleCfmMaControl 11 } sleCfmMaControlCcInterval OBJECT-TYPE SYNTAX Integer32 (2..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the interval between CCM transmissions" ::= { sleCfmMaControl 12 } sleCfmMaControlCcPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the CCM Priority" ::= { sleCfmMaControl 13 } sleCfmMaControlCcLossThreshold OBJECT-TYPE SYNTAX Integer32 (2..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the minimum number of CCMs that can be missed before declaring that a MEP is down" ::= { sleCfmMaControl 14 } sleCfmMaControlFaultPriority OBJECT-TYPE SYNTAX INTEGER { rdiccm(1), macstatus(2), remoteccm(3), errorccm(4), xconccm(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the lowest priority for fault alarm" ::= { sleCfmMaControl 15 } sleCfmMaControlFaultKeepTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the keep time for the fault alarm" ::= { sleCfmMaControl 16 } sleCfmMaControlFaultClearTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the clear time for the fault alarm" ::= { sleCfmMaControl 17 } sleCfmMaControlXcheckEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables CFM cross-check for a specific MEG" ::= { sleCfmMaControl 18 } sleCfmMaNotification OBJECT IDENTIFIER ::= { sleCfmMa 3 } sleCfmMaCreated NOTIFICATION-TYPE OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlName, sleCfmMaControlMdIndex, sleCfmMaControlVid } STATUS current DESCRIPTION "createCfmMa" ::= { sleCfmMaNotification 1 } sleCfmMaDeleted NOTIFICATION-TYPE OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlName, sleCfmMaControlMdIndex } STATUS current DESCRIPTION "deleteCfmMa" ::= { sleCfmMaNotification 2 } sleCfmMaMepEnableChanged NOTIFICATION-TYPE OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlIndex, sleCfmMaControlMdIndex, sleCfmMaControlMepEnable } STATUS current DESCRIPTION "setCfmMaMepEnable" ::= { sleCfmMaNotification 3 } sleCfmMaCcEnableChanged NOTIFICATION-TYPE OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlIndex, sleCfmMaControlMdIndex, sleCfmMaControlCcEnable } STATUS current DESCRIPTION "setCfmMaCcEnable" ::= { sleCfmMaNotification 4 } sleCfmMaCcProfileChanged NOTIFICATION-TYPE OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlIndex, sleCfmMaControlMdIndex, sleCfmMaControlCcInterval, sleCfmMaControlCcPriority, sleCfmMaControlCcLossThreshold } STATUS current DESCRIPTION "setCfmMaCcProfile" ::= { sleCfmMaNotification 5 } sleCfmMaFaultProfileChanged NOTIFICATION-TYPE OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlIndex, sleCfmMaControlMdIndex, sleCfmMaControlFaultPriority, sleCfmMaControlFaultKeepTime, sleCfmMaControlFaultClearTime } STATUS current DESCRIPTION "setCfmMaFaultProfile" ::= { sleCfmMaNotification 6 } sleCfmMaXcheckEnableChanged NOTIFICATION-TYPE OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlIndex, sleCfmMaControlMdIndex, sleCfmMaControlXcheckEnable } STATUS current DESCRIPTION "setCfmMaXcheckEnable" ::= { sleCfmMaNotification 7 } sleCfmMep OBJECT IDENTIFIER ::= { sleCfmOam 4 } sleCfmMepTable OBJECT-TYPE SYNTAX SEQUENCE OF SleCfmMepEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleCfmMep 1 } sleCfmMepEntry OBJECT-TYPE SYNTAX SleCfmMepEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleCfmMdIndex, sleCfmMaIndex, sleCfmMepIfIndex } ::= { sleCfmMepTable 1 } SleCfmMepEntry ::= SEQUENCE { sleCfmMepIdentifier Integer32, sleCfmMepIfIndex Integer32, sleCfmMepDirection INTEGER, sleCfmMepEnable INTEGER, sleCfmMepFngState INTEGER, sleCfmMepCcEnable INTEGER, sleCfmMepMacAddress OCTET STRING, sleCfmMepCcPriority Integer32, sleCfmMepFaultPriority INTEGER, sleCfmMepFaultKeepTime Integer32, sleCfmMepFaultClearTime Integer32, sleCfmMepHighestPrDefect INTEGER, sleCfmMepDefects BITS, sleCfmMepCciSentCcms Counter32, sleCfmMepNextLbmTransId Integer32, sleCfmMepLbrIn Counter32, sleCfmMepLbrInOutOfOrder Counter32, sleCfmMepLtmNextSeqNumber Integer32, sleCfmMepUnexpLtrIn Counter32 } sleCfmMepIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "MEP Id" ::= { sleCfmMepEntry 1 } sleCfmMepIfIndex OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Brige Port Index whitch the MEP is attached" ::= { sleCfmMepEntry 2 } sleCfmMepDirection OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The direction in which the MEP faces on the Bridge port" ::= { sleCfmMepEntry 3 } sleCfmMepEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Administrative state of the MEP" ::= { sleCfmMepEntry 4 } sleCfmMepFngState OBJECT-TYPE SYNTAX INTEGER { reset(1), defect(2), reportDefect(3), defectReported(4), defectCearing(5), defectCleared(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current state of the MEP Fault Notification Generator State Machine" ::= { sleCfmMepEntry 5 } sleCfmMepCcEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "If set to true, the MEP will generate CCM messages" ::= { sleCfmMepEntry 6 } sleCfmMepMacAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-only STATUS current DESCRIPTION "MAC address of the MEP" ::= { sleCfmMepEntry 7 } sleCfmMepCcPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the CCM Priority" ::= { sleCfmMepEntry 8 } sleCfmMepFaultPriority OBJECT-TYPE SYNTAX INTEGER { rdiccm(1), macstatus(2), remoteccm(3), errorccm(4), xconccm(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "An integer value specifying the lowest priority defect that is allowed to generate fault alarm" ::= { sleCfmMepEntry 9 } sleCfmMepFaultKeepTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-only STATUS current DESCRIPTION "The time that defects must be present before a Fault Alarm is issued" ::= { sleCfmMepEntry 10 } sleCfmMepFaultClearTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-only STATUS current DESCRIPTION "The time that defects must be absent before resetting a Fault Alarm" ::= { sleCfmMepEntry 11 } sleCfmMepHighestPrDefect OBJECT-TYPE SYNTAX INTEGER { rdiccm(1), macstatus(2), remoteccm(3), errorccm(4), xconccm(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The highest priority defect that has been present since the MEPs Fault Notification Generator State Machine was last in the FNG_RESET state" ::= { sleCfmMepEntry 12 } sleCfmMepDefects OBJECT-TYPE SYNTAX BITS { rdiccm(0), macstatus(1), remoteccm(2), errorccm(3), xconccm(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "A vector of Boolean defect conditions" ::= { sleCfmMepEntry 13 } sleCfmMepCciSentCcms OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of Continuity Check messages transmitted" ::= { sleCfmMepEntry 14 } sleCfmMepNextLbmTransId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Next sequence number/transaction identifier to be sent in a Loopback message" ::= { sleCfmMepEntry 15 } sleCfmMepLbrIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of valid, in-order Loopback Replies received" ::= { sleCfmMepEntry 16 } sleCfmMepLbrInOutOfOrder OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of valid, out-of-order Loopback Replies received" ::= { sleCfmMepEntry 17 } sleCfmMepLtmNextSeqNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Next transaction identifier/sequence number to be sent in a Linktrace message." ::= { sleCfmMepEntry 18 } sleCfmMepUnexpLtrIn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of unexpected LTRs received" ::= { sleCfmMepEntry 19 } sleCfmMepControl OBJECT IDENTIFIER ::= { sleCfmMep 2 } sleCfmMepControlRequest OBJECT-TYPE SYNTAX INTEGER { createCfmMep(1), deleteCfmMep(2), setCfmMepEnable(3), setCfmMepCcEnable(4), setCfmMepCcProfile(5), setCfmMepFaultProfile(6), transmitCfmLbm(7), transmitCfmLtm(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleCfmMepControl 1 } sleCfmMepControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleCfmMepControl 2 } sleCfmMepControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleCfmMepControl 3 } sleCfmMepControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleCfmMepControl 4 } sleCfmMepControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleCfmMepControl 5 } sleCfmMepControlIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "MEP Id" ::= { sleCfmMepControl 6 } sleCfmMepControlMdIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "A index of MD table" ::= { sleCfmMepControl 7 } sleCfmMepControlMaIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The MA's Index" ::= { sleCfmMepControl 8 } sleCfmMepControlIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Bridge Port Index whitch the MEP is attached" ::= { sleCfmMepControl 9 } sleCfmMepControlDirection OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The direction in which the MEP faces on the Bridge port" ::= { sleCfmMepControl 10 } sleCfmMepControlEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Administrative state of the MEP" ::= { sleCfmMepControl 11 } sleCfmMepControlCcEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "If set to true, the MEP will generate CCM messages" ::= { sleCfmMepControl 12 } sleCfmMepControlCcPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the CCM Priority" ::= { sleCfmMepControl 13 } sleCfmMepControlFaultPriority OBJECT-TYPE SYNTAX INTEGER { rdiccm(1), macstatus(2), remoteccm(3), errorccm(4), xconccm(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "An integer value specifying the lowest priority defect that is allowed to generate fault alarm" ::= { sleCfmMepControl 14 } sleCfmMepControlFaultKeepTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-write STATUS current DESCRIPTION "The time that defects must be present before a Fault Alarm is issued" ::= { sleCfmMepControl 15 } sleCfmMepControlFaultClearTime OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-write STATUS current DESCRIPTION "The time that defects must be absent before resetting a Fault Alarm" ::= { sleCfmMepControl 16 } sleCfmMepControlTransmitLbmDestMacAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-write STATUS current DESCRIPTION "The Target MAC Address Field to be transmitted" ::= { sleCfmMepControl 17 } sleCfmMepControlTransmitLbmDestMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the LBM is to be sent" ::= { sleCfmMepControl 18 } sleCfmMepControlTransmitLbmDestIsMepId OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "True indicates that MEPID of the target MEP is used for Loopback transmission" ::= { sleCfmMepControl 19 } sleCfmMepControlTransmitLbmCount OBJECT-TYPE SYNTAX Integer32 (1..6000) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of Loopback messages to be transmitted" ::= { sleCfmMepControl 20 } sleCfmMepControlTransmitLbmInterval OBJECT-TYPE SYNTAX Integer32 (2..4) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the interval for sending LBM" ::= { sleCfmMepControl 21 } sleCfmMepControlTransmitLbmTimeout OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the waiting time for receiving the expected LBR" ::= { sleCfmMepControl 22 } sleCfmMepControlTransmitLbmPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Priority. 3 bit value to be used in the VLAN tag" ::= { sleCfmMepControl 23 } sleCfmMepControlTransmitLtmTargetMacAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-write STATUS current DESCRIPTION "The Target MAC Address Field to be transmitted: A unicast destination MAC address." ::= { sleCfmMepControl 24 } sleCfmMepControlTransmitLtmTargetMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "An indication of the Target MAC Address Field to be transmitted" ::= { sleCfmMepControl 25 } sleCfmMepControlTransmitLtmTargetIsMepId OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "True indicates that MEPID of the target MEP is used for Linktrace transmission." ::= { sleCfmMepControl 26 } sleCfmMepControlTransmitLtmFlags OBJECT-TYPE SYNTAX BITS { useFDBonly(0) } MAX-ACCESS read-write STATUS current DESCRIPTION "The flags field for LTMs transmitted by the MEP" ::= { sleCfmMepControl 27 } sleCfmMepControlTransmitLtmTtl OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-write STATUS current DESCRIPTION "The LTM TTL field" ::= { sleCfmMepControl 28 } sleCfmMepNotification OBJECT IDENTIFIER ::= { sleCfmMep 3 } sleCfmMepCreated NOTIFICATION-TYPE OBJECTS { sleCfmMepControlRequest, sleCfmMepControlTimeStamp, sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex, sleCfmMepControlMaIndex, sleCfmMepControlIfIndex, sleCfmMepControlDirection } STATUS current DESCRIPTION "createCfmMep" ::= { sleCfmMepNotification 1 } sleCfmMepDeleted NOTIFICATION-TYPE OBJECTS { sleCfmMepControlRequest, sleCfmMepControlTimeStamp, sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex, sleCfmMepControlMaIndex } STATUS current DESCRIPTION "deleteCfmMep" ::= { sleCfmMepNotification 2 } sleCfmMepEnableChanged NOTIFICATION-TYPE OBJECTS { sleCfmMepControlRequest, sleCfmMepControlTimeStamp, sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex, sleCfmMepControlMaIndex, sleCfmMepControlEnable } STATUS current DESCRIPTION "setCfmMepEnable" ::= { sleCfmMepNotification 3 } sleCfmMepCcEnableChanged NOTIFICATION-TYPE OBJECTS { sleCfmMepControlRequest, sleCfmMepControlTimeStamp, sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex, sleCfmMepControlMaIndex, sleCfmMepControlCcEnable } STATUS current DESCRIPTION "setCfmMepCcEnable" ::= { sleCfmMepNotification 4 } sleCfmMepCcProfileChanged NOTIFICATION-TYPE OBJECTS { sleCfmMepControlRequest, sleCfmMepControlTimeStamp, sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex, sleCfmMepControlMaIndex, sleCfmMdControlCcPriority } STATUS current DESCRIPTION "setCfmMepCcProfile" ::= { sleCfmMepNotification 5 } sleCfmMepFaultProfileChanged NOTIFICATION-TYPE OBJECTS { sleCfmMepControlRequest, sleCfmMepControlTimeStamp, sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex, sleCfmMepControlMaIndex, sleCfmMepControlFaultPriority, sleCfmMepControlFaultKeepTime, sleCfmMepControlFaultClearTime } STATUS current DESCRIPTION "setCfmMepFaultProfile" ::= { sleCfmMepNotification 6 } sleCfmMip OBJECT IDENTIFIER ::= { sleCfmOam 5 } sleCfmMipTable OBJECT-TYPE SYNTAX SEQUENCE OF SleCfmMipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleCfmMip 1 } sleCfmMipEntry OBJECT-TYPE SYNTAX SleCfmMipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleCfmMipPort } ::= { sleCfmMipTable 1 } SleCfmMipEntry ::= SEQUENCE { sleCfmMipPort Integer32, sleCfmMipLevel Integer32, sleCfmMipType INTEGER } sleCfmMipPort OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the port number" ::= { sleCfmMipEntry 1 } sleCfmMipLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the MIP's level" ::= { sleCfmMipEntry 2 } sleCfmMipType OBJECT-TYPE SYNTAX INTEGER { static(1), dynamic(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate the MIP¡¯s type" ::= { sleCfmMipEntry 3 } sleCfmMipControl OBJECT IDENTIFIER ::= { sleCfmMip 2 } sleCfmMipControlRequest OBJECT-TYPE SYNTAX INTEGER { createCfmMip(1), deleteCfmMip(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleCfmMipControl 1 } sleCfmMipControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleCfmMipControl 2 } sleCfmMipControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleCfmMipControl 3 } sleCfmMipControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleCfmMipControl 4 } sleCfmMipControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleCfmMipControl 5 } sleCfmMipControlPort OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the port number" ::= { sleCfmMipControl 6 } sleCfmMipControlLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the MIP's level" ::= { sleCfmMipControl 7 } sleCfmMipNotification OBJECT IDENTIFIER ::= { sleCfmMip 3 } sleCfmMipCreated NOTIFICATION-TYPE OBJECTS { sleCfmMipControlRequest, sleCfmMipControlTimeStamp, sleCfmMipControlReqResult, sleCfmMipControlPort, sleCfmMipControlLevel } STATUS current DESCRIPTION "createCfmMip" ::= { sleCfmMipNotification 1 } sleCfmMipDeleted NOTIFICATION-TYPE OBJECTS { sleCfmMipControlRequest, sleCfmMipControlTimeStamp, sleCfmMipControlReqResult, sleCfmMipControlPort } STATUS current DESCRIPTION "deleteCfmMip" ::= { sleCfmMipNotification 2 } sleCfmXcheck OBJECT IDENTIFIER ::= { sleCfmOam 6 } sleCfmXcheckTable OBJECT-TYPE SYNTAX SEQUENCE OF SleCfmXcheckEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleCfmXcheck 1 } sleCfmXcheckEntry OBJECT-TYPE SYNTAX SleCfmXcheckEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleCfmMdIndex, sleCfmMaIndex, sleCfmXcheckMepIdentifier } ::= { sleCfmXcheckTable 1 } SleCfmXcheckEntry ::= SEQUENCE { sleCfmXcheckMepIdentifier Integer32, sleCfmXcheckMepState INTEGER } sleCfmXcheckMepIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the remote MEP's Id" ::= { sleCfmXcheckEntry 1 } sleCfmXcheckMepState OBJECT-TYPE SYNTAX INTEGER { unknown(0), missing(1), up(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the cross-check MEP¡¯s state" ::= { sleCfmXcheckEntry 2 } sleCfmXcheckControl OBJECT IDENTIFIER ::= { sleCfmXcheck 2 } sleCfmXcheckControlRequest OBJECT-TYPE SYNTAX INTEGER { createCfmXcheckMep(1), deleteCfmXcheckMep(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleCfmXcheckControl 1 } sleCfmXcheckControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleCfmXcheckControl 2 } sleCfmXcheckControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleCfmXcheckControl 3 } sleCfmXcheckControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleCfmXcheckControl 4 } sleCfmXcheckControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleCfmXcheckControl 5 } sleCfmXcheckControlMepIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the remote MEP's Id" ::= { sleCfmXcheckControl 6 } sleCfmXcheckControlMdIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the MD¡¯s Index" ::= { sleCfmXcheckControl 7 } sleCfmXcheckControlMaIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the MA's Index" ::= { sleCfmXcheckControl 8 } sleCfmXcheckNotification OBJECT IDENTIFIER ::= { sleCfmXcheck 3 } sleCfmXcheckMepCreated NOTIFICATION-TYPE OBJECTS { sleCfmXcheckControlRequest, sleCfmXcheckControlTimeStamp, sleCfmXcheckControlReqResult, sleCfmXcheckControlMepIdentifier, sleCfmXcheckControlMdIndex, sleCfmXcheckControlMaIndex } STATUS current DESCRIPTION "createCfmXcheckMep" ::= { sleCfmXcheckNotification 1 } sleCfmXcheckMepDeleted NOTIFICATION-TYPE OBJECTS { sleCfmXcheckControlRequest, sleCfmXcheckControlTimeStamp, sleCfmXcheckControlReqResult, sleCfmXcheckControlMepIdentifier, sleCfmXcheckControlMdIndex, sleCfmXcheckControlMaIndex } STATUS current DESCRIPTION "deleteCfmXcheckMep" ::= { sleCfmXcheckNotification 2 } sleCfmRmep OBJECT IDENTIFIER ::= { sleCfmOam 7 } sleCfmRmepTable OBJECT-TYPE SYNTAX SEQUENCE OF SleCfmRmepEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleCfmRmep 1 } sleCfmRmepEntry OBJECT-TYPE SYNTAX SleCfmRmepEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleCfmMdIndex, sleCfmMaIndex, sleCfmMepIdentifier, sleCfmRmepIdentifier } ::= { sleCfmRmepTable 1 } SleCfmRmepEntry ::= SEQUENCE { sleCfmRmepIdentifier Integer32, sleCfmRmepState INTEGER, sleCfmRmepMacAddress OCTET STRING, sleCfmRmepIfIndex Integer32, sleCfmRmepRdi INTEGER, sleCfmRmepPortStatus INTEGER, sleCfmRmepInterfaceStatus INTEGER } sleCfmRmepIdentifier OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the remote MEP's Id" ::= { sleCfmRmepEntry 1 } sleCfmRmepState OBJECT-TYPE SYNTAX INTEGER { idle(1), start(2), failed(3), ok(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the operational state of the remote MEP State machines" ::= { sleCfmRmepEntry 2 } sleCfmRmepMacAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the MAC address of the remote MEP" ::= { sleCfmRmepEntry 3 } sleCfmRmepIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the port number of the remote MEP" ::= { sleCfmRmepEntry 4 } sleCfmRmepRdi OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates State of the RDI bit in the last received CCM (true for RDI=1), or false if none has been received" ::= { sleCfmRmepEntry 5 } sleCfmRmepPortStatus OBJECT-TYPE SYNTAX INTEGER { none(1), up(2), down(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Port status of the remote MEP" ::= { sleCfmRmepEntry 6 } sleCfmRmepInterfaceStatus OBJECT-TYPE SYNTAX INTEGER { none(1), up(2), down(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the interface status of the remote MEP" ::= { sleCfmRmepEntry 7 } sleCfmLtr OBJECT IDENTIFIER ::= { sleCfmOam 8 } sleCfmLtrTable OBJECT-TYPE SYNTAX SEQUENCE OF SleCfmLtrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleCfmLtr 1 } sleCfmLtrEntry OBJECT-TYPE SYNTAX SleCfmLtrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleCfmMdIndex, sleCfmMaIndex, sleCfmMepIdentifier, sleCfmLtrSeqNumber, sleCfmLtrReceiveOrder } ::= { sleCfmLtrTable 1 } SleCfmLtrEntry ::= SEQUENCE { sleCfmLtrSeqNumber Integer32, sleCfmLtrReceiveOrder Integer32, sleCfmLtrTtl Integer32, sleCfmLtrForwarded INTEGER, sleCfmLtrTerminalMep INTEGER, sleCfmLtrLastEgressIdentifier OCTET STRING, sleCfmLtrNextEgressIdentifier OCTET STRING, sleCfmLtrRelay INTEGER, sleCfmLtrIngress INTEGER, sleCfmLtrIngressMac OCTET STRING, sleCfmLtrIngressPort Integer32, sleCfmLtrEgress INTEGER, sleCfmLtrEgressMac OCTET STRING, sleCfmLtrEgressPort Integer32 } sleCfmLtrSeqNumber OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the LTM Transaction Identifier returned from a previous Transmit Linktrace Message command, indicating the LTM entry to which the LTR entries will be attached " ::= { sleCfmLtrEntry 1 } sleCfmLtrReceiveOrder OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates an index to distinguish among multiple LTRs with the same LTR Transaction Identifier field value" ::= { sleCfmLtrEntry 2 } sleCfmLtrTtl OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates TTL field value for a returned LTR." ::= { sleCfmLtrEntry 3 } sleCfmLtrForwarded OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if a LTM was forwarded by the responding MP, as returned in the 'FwdYes' flag of the flags field." ::= { sleCfmLtrEntry 4 } sleCfmLtrTerminalMep OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates a boolean value stating whether the forwarded LTM reached a MEP enclosing its MA, as returned in the Terminal MEP flag of the Flags field. " ::= { sleCfmLtrEntry 5 } sleCfmLtrLastEgressIdentifier OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the MEP Linktrace Initiator that originated, or the Linktrace Responder that forwarded, the LTM to which this LTR is the response" ::= { sleCfmLtrEntry 6 } sleCfmLtrNextEgressIdentifier OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the Linktrace Responder that transmitted this LTR, and can forward the LTM to the next hop." ::= { sleCfmLtrEntry 7 } sleCfmLtrRelay OBJECT-TYPE SYNTAX INTEGER { rlyHit(1), rlyFDB(2), rlyMPDB(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the value returned in the Ingress Action Field of the LTM" ::= { sleCfmLtrEntry 8 } sleCfmLtrIngress OBJECT-TYPE SYNTAX INTEGER { ingNoTlv(0), ingOK(1), ingDown(2), ingBlocked(3), ingVid(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the value returned in the Ingress Action Field of the LTM" ::= { sleCfmLtrEntry 9 } sleCfmLtrIngressMac OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates MAC address returned in the ingress MAC address field." ::= { sleCfmLtrEntry 10 } sleCfmLtrIngressPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates Ingress Port ID" ::= { sleCfmLtrEntry 11 } sleCfmLtrEgress OBJECT-TYPE SYNTAX INTEGER { egrNoTlv(0), egrOK(1), egrDown(2), egrBlocked(3), egrVid(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the value returned in the Egress Action Field of the LTM" ::= { sleCfmLtrEntry 12 } sleCfmLtrEgressMac OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates MAC address returned in the egress MAC address field." ::= { sleCfmLtrEntry 13 } sleCfmLtrEgressPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates Egress Port ID" ::= { sleCfmLtrEntry 14 } sleCfmConfigError OBJECT IDENTIFIER ::= { sleCfmOam 9 } sleCfmConfigErrorTable OBJECT-TYPE SYNTAX SEQUENCE OF SleCfmConfigErrorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleCfmConfigError 1 } sleCfmConfigErrorEntry OBJECT-TYPE SYNTAX SleCfmConfigErrorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleCfmConfigErrorVid, sleCfmConfigErrorIfIndex } ::= { sleCfmConfigErrorTable 1 } SleCfmConfigErrorEntry ::= SEQUENCE { sleCfmConfigErrorVid Integer32, sleCfmConfigErrorIfIndex Integer32, sleCfmConfigErrorType BITS } sleCfmConfigErrorVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Configuration Error VLAN Identifier" ::= { sleCfmConfigErrorEntry 1 } sleCfmConfigErrorIfIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Configuration Error Port Number" ::= { sleCfmConfigErrorEntry 2 } sleCfmConfigErrorType OBJECT-TYPE SYNTAX BITS { cfmleak(0), conflictingVids(1), excessiveLevels(2), overlappedLevels(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Configuration Error Type" ::= { sleCfmConfigErrorEntry 3 } sleCfmMipCcdb OBJECT IDENTIFIER ::= { sleCfmOam 10 } sleCfmMipCcdbTable OBJECT-TYPE SYNTAX SEQUENCE OF SleCfmMipCcdbEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleCfmMipCcdb 1 } sleCfmMipCcdbEntry OBJECT-TYPE SYNTAX SleCfmMipCcdbEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleCfmMipCcdbIndex } ::= { sleCfmMipCcdbTable 1 } SleCfmMipCcdbEntry ::= SEQUENCE { sleCfmMipCcdbIndex Integer32, sleCfmMipCcdbVlanId Integer32, sleCfmMipCcdbMacAddr OCTET STRING, sleCfmMipCcdbPort Integer32, sleCfmMipCcdbKeepTime OCTET STRING } sleCfmMipCcdbIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the MIP CCDB's Index" ::= { sleCfmMipCcdbEntry 1 } sleCfmMipCcdbVlanId OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "VLAN Id" ::= { sleCfmMipCcdbEntry 2 } sleCfmMipCcdbMacAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates MAC address of the remote MEP" ::= { sleCfmMipCcdbEntry 3 } sleCfmMipCcdbPort OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Port number that the CCM output" ::= { sleCfmMipCcdbEntry 4 } sleCfmMipCcdbKeepTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates an up-date time of a entry" ::= { sleCfmMipCcdbEntry 5 } sleEMLog OBJECT IDENTIFIER ::= { sleFaultMgmt 14 } sleEMLogInfo OBJECT IDENTIFIER ::= { sleEMLog 1 } sleEMLogDisableStatus OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "EM log disable." ::= { sleEMLogInfo 1 } sleEMLogAction OBJECT-TYPE SYNTAX BITS { syslog(0), trap(1), recover(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Generate syslog message or SNMP Trap or take a recover action " ::= { sleEMLogInfo 2 } sleEMLogInterval OBJECT-TYPE SYNTAX INTEGER (1..1440) MAX-ACCESS read-only STATUS current DESCRIPTION "Action interval in minute (Default. 3 mins)" ::= { sleEMLogInfo 3 } sleEMLogNAKLockStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of emlog nak-locking" ::= { sleEMLogInfo 4 } sleEMLogNakCompensate OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of emlog nak-compensate (shadow recovery)" ::= { sleEMLogInfo 5 } sleEMLogRecoverActionMemLow OBJECT-TYPE SYNTAX INTEGER { switchover(1), none(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate recover action of memory low" ::= { sleEMLogInfo 6 } sleEMLogRecoverActionNak OBJECT-TYPE SYNTAX INTEGER { switchover(1), none(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate recover action of NAK error" ::= { sleEMLogInfo 7 } sleEMLogControl OBJECT IDENTIFIER ::= { sleEMLog 2 } sleEMLogControlRequest OBJECT-TYPE SYNTAX INTEGER { setDisableStatus(1), setAction(2), setInterval(3), setNAKLock(4), setNAKCompensate(5), setRecoverActionMemLow(6), setRecoverActionNAK(7) } MAX-ACCESS read-write STATUS current DESCRIPTION " This attribute identifies the control commands. updateAlarmList: the NE updates entries of alarms in the sleAlarmListTable after having changed alarm severities of alarms (due to change profile pointers in managed entities or after modification of alarm severities in profiles). This command should be applied once after having finisled modifications of severties. modifyAlarmSeverity: modifies the severity of an alarm in specific profile. createAlarmSeverityProfile: creates a new profile with default severities. The severities then have to be modified with command changeAlarmSeverity. deleteAlarmSeverityProfile: deletes a profile. Profile 1 is not allowed to be deleted. Notifications : none " ::= { sleEMLogControl 1 } sleEMLogControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION " The status of a control request. " ::= { sleEMLogControl 2 } sleEMLogControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION " The maximum wait time for the manager for command ending. For long running commands. The manager reads this value from the DSLAM. " ::= { sleEMLogControl 3 } sleEMLogControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION " The time stamp of the last command (end of command). " ::= { sleEMLogControl 4 } sleEMLogControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION " The result of the last user command. " ::= { sleEMLogControl 5 } sleEMLogControlDisableStatus OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "EM log disable." ::= { sleEMLogControl 6 } sleEMLogControlAction OBJECT-TYPE SYNTAX BITS { syslog(0), trap(1), recover(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Generate syslog message or SNMP trap." ::= { sleEMLogControl 7 } sleEMLogControlInterval OBJECT-TYPE SYNTAX INTEGER (1..1440) MAX-ACCESS read-write STATUS current DESCRIPTION "Action interval in minute (Default. 3 mins)" ::= { sleEMLogControl 8 } sleEMLogControlNAKLockStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of emlog nak-locking" ::= { sleEMLogControl 9 } sleEMLogControlNAKCompensate OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of emlog nak-compensate (shadow recovery)" ::= { sleEMLogControl 10 } sleEMLogControlRecoverActionMemLow OBJECT-TYPE SYNTAX INTEGER { switchover(1), none(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicate recover action of memory low" ::= { sleEMLogControl 11 } sleEMLogControlRecoverActionNAK OBJECT-TYPE SYNTAX INTEGER { switchover(1), none(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicate recover action of NAK error " ::= { sleEMLogControl 12 } sleEMLogNotification OBJECT IDENTIFIER ::= { sleEMLog 3 } sleEMLogDisableStatusChanged NOTIFICATION-TYPE OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlDisableStatus } STATUS current DESCRIPTION "Description." ::= { sleEMLogNotification 1 } sleEMLogActionChanged NOTIFICATION-TYPE OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlAction } STATUS current DESCRIPTION "Description." ::= { sleEMLogNotification 2 } sleEMLogIntervalChanged NOTIFICATION-TYPE OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlInterval } STATUS current DESCRIPTION "Description." ::= { sleEMLogNotification 3 } sleEMLogNAKLockChanged NOTIFICATION-TYPE OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlNAKLockStatus } STATUS current DESCRIPTION "Description." ::= { sleEMLogNotification 4 } sleEMLogNAKCompensateChanged NOTIFICATION-TYPE OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlNAKCompensate } STATUS current DESCRIPTION "Description." ::= { sleEMLogNotification 5 } sleEMLogRecoverActionMemLowChanged NOTIFICATION-TYPE OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlRecoverActionMemLow } STATUS current DESCRIPTION "Description." ::= { sleEMLogNotification 6 } sleEMLogRecoverActionNAKChanged NOTIFICATION-TYPE OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlRecoverActionNAK } STATUS current DESCRIPTION "Description." ::= { sleEMLogNotification 7 } sleEMLogDefectInfo OBJECT IDENTIFIER ::= { sleEMLog 4 } sleEMLogDefectCPUHigh OBJECT-TYPE SYNTAX BITS { slot1(0), slot2(1), slot3(2), slot4(3), slot5(4), slot6(5), slot7(6), slot8(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The CPU high defection information." ::= { sleEMLogDefectInfo 1 } sleEMLogTemperHigh OBJECT-TYPE SYNTAX BITS { slot1(0), slot2(1), slot3(2), slot4(3), slot5(4), slot6(5), slot7(6), slot8(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature hish defection information." ::= { sleEMLogDefectInfo 2 } sleEMLogTemperLow OBJECT-TYPE SYNTAX BITS { slot1(0), slot2(1), slot3(2), slot4(3), slot5(4), slot6(5), slot7(6), slot8(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature low defection information." ::= { sleEMLogDefectInfo 3 } sleEMLogMemLow OBJECT-TYPE SYNTAX BITS { slot1(0), slot2(1), slot3(2), slot4(3), slot5(4), slot6(5), slot7(6), slot8(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The memory low defection information." ::= { sleEMLogDefectInfo 4 } sleEMLogFanFail OBJECT-TYPE SYNTAX BITS { slot1(0), slot2(1), slot3(2), slot4(3), slot5(4), slot6(5), slot7(6), slot8(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The fan failure defection information." ::= { sleEMLogDefectInfo 5 } sleEMLogPhyCRCFail OBJECT-TYPE SYNTAX BITS { slot1(0), slot2(1), slot3(2), slot4(3), slot5(4), slot6(5), slot7(6), slot8(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The PHY CRC failure defection information." ::= { sleEMLogDefectInfo 6 } sleEMLogPhyDetectFail OBJECT-TYPE SYNTAX BITS { slot1(0), slot2(1), slot3(2), slot4(3), slot5(4), slot6(5), slot7(6), slot8(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The PHY detection failure defection information." ::= { sleEMLogDefectInfo 7 } sleEMLogSFUMateInitFail OBJECT-TYPE SYNTAX BITS { slot1(0), slot2(1), slot3(2), slot4(3), slot5(4), slot6(5), slot7(6), slot8(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The SFU mate init failure defection information" ::= { sleEMLogDefectInfo 8 } sleEMLogDaemonHealthBad OBJECT-TYPE SYNTAX BITS { slot1(0), slot2(1), slot3(2), slot4(3), slot5(4), slot6(5), slot7(6), slot8(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The daemon health bad defection information." ::= { sleEMLogDefectInfo 9 } sleEMLogGPIURavenLinkDown OBJECT-TYPE SYNTAX BITS { slot1(0), slot2(1), slot3(2), slot4(3), slot5(4), slot6(5), slot7(6), slot8(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The GPIU raven link down defection information." ::= { sleEMLogDefectInfo 10 } sleEMLogFANRPMLow OBJECT-TYPE SYNTAX BITS { slot1(0), slot2(1), slot3(2), slot4(3), slot5(4), slot6(5), slot7(6), slot8(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The FAN RPM Low defection information." ::= { sleEMLogDefectInfo 11 } sleEMLogNAK OBJECT-TYPE SYNTAX BITS { slot1(0), slot2(1), slot3(2), slot4(3), slot5(4), slot6(5), slot7(6), slot8(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The NAK Error defection information." ::= { sleEMLogDefectInfo 12 } sleRapsRing OBJECT IDENTIFIER ::= { sleFaultMgmt 15 } sleRapsRingTable OBJECT-TYPE SYNTAX SEQUENCE OF SleRapsRingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleRapsRing 1 } sleRapsRingEntry OBJECT-TYPE SYNTAX SleRapsRingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleRapsRingId } ::= { sleRapsRingTable 1 } SleRapsRingEntry ::= SEQUENCE { sleRapsRingId Integer32, sleRapsRingType INTEGER, sleRapsRingLevel INTEGER, sleRapsRingCtrlVlan INTEGER, sleRapsRingTrafficVlans OCTET STRING, sleRapsRingVirtualVlan INTEGER, sleRapsRingNodeId OCTET STRING, sleRapsRingEnable INTEGER, sleRapsRingBridgeRole INTEGER, sleRapsRingState INTEGER, sleRapsRingEastPort Integer32, sleRapsRingEastPortStatus INTEGER, sleRapsRingWestPort Integer32, sleRapsRingWestPortStatus INTEGER, sleRapsRingRplPort INTEGER, sleRapsRingIcPort INTEGER, sleRapsRingIcNode INTEGER, sleRapsRingMultipleFailure INTEGER, sleRapsRingPropagateTc INTEGER, sleRapsRingNonRevertive INTEGER, sleRapsRingForcedSwitch INTEGER, sleRapsRingManualSwitch INTEGER, sleRapsRingHoldOffTime INTEGER, sleRapsRingGuardTime INTEGER, sleRapsRingWaitToRestore INTEGER, sleRapsRingWaitToBlock INTEGER, sleRapsRingInstId Integer32, sleRapsRingChannel INTEGER, sleRapsRingPassThrough INTEGER, sleRapsRingVerifiedTime INTEGER } sleRapsRingId OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring¡¯s ID" ::= { sleRapsRingEntry 1 } sleRapsRingType OBJECT-TYPE SYNTAX INTEGER { major(1), sub(2), access(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring¡¯s type" ::= { sleRapsRingEntry 2 } sleRapsRingLevel OBJECT-TYPE SYNTAX INTEGER (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring¡¯s level" ::= { sleRapsRingEntry 3 } sleRapsRingCtrlVlan OBJECT-TYPE SYNTAX INTEGER (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring Node¡¯s control-vlan" ::= { sleRapsRingEntry 4 } sleRapsRingTrafficVlans OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring Node¡¯s traffic-vlans" ::= { sleRapsRingEntry 5 } sleRapsRingVirtualVlan OBJECT-TYPE SYNTAX INTEGER (0..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring Node's virtual-vlan" ::= { sleRapsRingEntry 6 } sleRapsRingNodeId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring Node¡¯s ID" ::= { sleRapsRingEntry 7 } sleRapsRingEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enables/Disables Ring Node" ::= { sleRapsRingEntry 8 } sleRapsRingBridgeRole OBJECT-TYPE SYNTAX INTEGER { normal(0), rplowner(1), rplneighbour(2), rplnextneighbour(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring Node¡¯s Role" ::= { sleRapsRingEntry 9 } sleRapsRingState OBJECT-TYPE SYNTAX INTEGER { none(0), idle(1), protection(2), manual(3), forced(4), pending(5), required(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring Node¡¯s State" ::= { sleRapsRingEntry 10 } sleRapsRingEastPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring Node¡¯s east port" ::= { sleRapsRingEntry 11 } sleRapsRingEastPortStatus OBJECT-TYPE SYNTAX INTEGER { none(0), disabled(1), forwarding(2), blocking(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the port status of east port" ::= { sleRapsRingEntry 12 } sleRapsRingWestPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring Node¡¯s west port" ::= { sleRapsRingEntry 13 } sleRapsRingWestPortStatus OBJECT-TYPE SYNTAX INTEGER { none(0), disabled(1), forwarding(2), blocking(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the port status of west port" ::= { sleRapsRingEntry 14 } sleRapsRingRplPort OBJECT-TYPE SYNTAX INTEGER { none(0), east(1), west(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring¡¯s RPL port" ::= { sleRapsRingEntry 15 } sleRapsRingIcPort OBJECT-TYPE SYNTAX INTEGER { none(0), east(1), west(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring¡¯s interconnection port" ::= { sleRapsRingEntry 16 } sleRapsRingIcNode OBJECT-TYPE SYNTAX INTEGER { none(0), primary(1), secondary(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the primary/secondary node for the minimization of the segmentation" ::= { sleRapsRingEntry 17 } sleRapsRingMultipleFailure OBJECT-TYPE SYNTAX INTEGER { none(0), primary(1), secondary(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The multiple failure mode" ::= { sleRapsRingEntry 18 } sleRapsRingPropagateTc OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The propagation TC(topology change)" ::= { sleRapsRingEntry 19 } sleRapsRingNonRevertive OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Non-Revertive" ::= { sleRapsRingEntry 20 } sleRapsRingForcedSwitch OBJECT-TYPE SYNTAX INTEGER { none(0), east(1), west(2), both(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Forced Switch" ::= { sleRapsRingEntry 21 } sleRapsRingManualSwitch OBJECT-TYPE SYNTAX INTEGER { none(0), east(1), west(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Manual Switch" ::= { sleRapsRingEntry 22 } sleRapsRingHoldOffTime OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the hold-off time" ::= { sleRapsRingEntry 23 } sleRapsRingGuardTime OBJECT-TYPE SYNTAX INTEGER (10..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the guard time" ::= { sleRapsRingEntry 24 } sleRapsRingWaitToRestore OBJECT-TYPE SYNTAX INTEGER (1..12) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the wait-to-restore time" ::= { sleRapsRingEntry 25 } sleRapsRingWaitToBlock OBJECT-TYPE SYNTAX INTEGER (5..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the wait-to-block time" ::= { sleRapsRingEntry 26 } sleRapsRingInstId OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ring instance ID." ::= { sleRapsRingEntry 27 } sleRapsRingChannel OBJECT-TYPE SYNTAX INTEGER { none(0), virtual(1), abstract(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the R-APS channel type." ::= { sleRapsRingEntry 28 } sleRapsRingPassThrough OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the pass-through funtion." ::= { sleRapsRingEntry 29 } sleRapsRingVerifiedTime OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the verified time" ::= { sleRapsRingEntry 30 } sleRapsRingControl OBJECT IDENTIFIER ::= { sleRapsRing 2 } sleRapsRingControlRequest OBJECT-TYPE SYNTAX INTEGER { createRapsRing(1), deleteRapsRing(2), setRapsRingChannel(3), setRapsRingEnable(4), setRapsRingPorts(5), destroyRapsRingPorts(6), setRapsRingRplPort(7), setRapsRingIcPort(8), destroyRapsRingIcPort(9), setRapsRingMultipleFailure(10), setRapsRingPropagateTc(11), setRapsRingNonRevertive(12), setRapsRingForcedSwitch(13), setRapsRingManualSwitch(14), setRapsRingClearSwitch(15), setRapsRingHoldOffTime(16), setRapsRingGuardTime(17), setRapsRingWtrTime(18), setRapsRingWtbTime(19), setRapsRingPassThrough(20), setRapsRingVrfTime(21) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleRapsRingControl 1 } sleRapsRingControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleRapsRingControl 2 } sleRapsRingControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleRapsRingControl 3 } sleRapsRingControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleRapsRingControl 4 } sleRapsRingControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleRapsRingControl 5 } sleRapsRingControlId OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Ring¡¯s ID" ::= { sleRapsRingControl 6 } sleRapsRingControlType OBJECT-TYPE SYNTAX INTEGER { major(1), sub(2), access(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Ring¡¯s type" ::= { sleRapsRingControl 7 } sleRapsRingControlLevel OBJECT-TYPE SYNTAX INTEGER (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Ring¡¯s level" ::= { sleRapsRingControl 8 } sleRapsRingControlCtrlVlan OBJECT-TYPE SYNTAX INTEGER (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Ring Node¡¯s control-vlan" ::= { sleRapsRingControl 9 } sleRapsRingControlTrafficVlans OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Ring Node¡¯s traffic-vlans" ::= { sleRapsRingControl 10 } sleRapsRingControlChannel OBJECT-TYPE SYNTAX INTEGER { none(0), virtual(1), abstract(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Ring Node's channel" ::= { sleRapsRingControl 11 } sleRapsRingControlEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "IEnables/Disables Ring Node" ::= { sleRapsRingControl 12 } sleRapsRingControlEastPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Ring Node¡¯s east port" ::= { sleRapsRingControl 13 } sleRapsRingControlWestPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Ring Node¡¯s west port" ::= { sleRapsRingControl 14 } sleRapsRingControlParamPort OBJECT-TYPE SYNTAX INTEGER { east(1), west(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the rpl port, interconnection port, forced or manual switch port." ::= { sleRapsRingControl 15 } sleRapsRingControlBridgeRole OBJECT-TYPE SYNTAX INTEGER { none(0), rplowner(1), neighbour(2), nextneighbour(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Ring¡¯s RPL port type" ::= { sleRapsRingControl 16 } sleRapsRingControlIcNode OBJECT-TYPE SYNTAX INTEGER { primary(1), secondary(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the primary/secondary node for the minimization of the segmentation" ::= { sleRapsRingControl 17 } sleRapsRingControlMultipleFailure OBJECT-TYPE SYNTAX INTEGER { none(0), primary(1), secondary(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The multiple failure of Ring Node" ::= { sleRapsRingControl 18 } sleRapsRingControlPropagateTc OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The propagation TC" ::= { sleRapsRingControl 19 } sleRapsRingControlNonRevertive OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Non-Revertive" ::= { sleRapsRingControl 20 } sleRapsRingControlHoldOffTime OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the hold-off time. The hold-off time's step must be 100 " ::= { sleRapsRingControl 21 } sleRapsRingControlGuardTime OBJECT-TYPE SYNTAX INTEGER (10..2000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the guard time. The guard time's step must be 10. " ::= { sleRapsRingControl 22 } sleRapsRingControlWaitToRestore OBJECT-TYPE SYNTAX INTEGER (1..12) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the wait-to-restore time " ::= { sleRapsRingControl 23 } sleRapsRingControlWaitToBlock OBJECT-TYPE SYNTAX INTEGER (5..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the wait-to-block time" ::= { sleRapsRingControl 24 } sleRapsRingControlInstId OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the ring instance ID." ::= { sleRapsRingControl 25 } sleRapsRingControlPassThrough OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the pass-through function." ::= { sleRapsRingControl 26 } sleRapsRingControlVerifiedTime OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the verified time." ::= { sleRapsRingControl 27 } sleRapsRingNotification OBJECT IDENTIFIER ::= { sleRapsRing 3 } sleRapsRingCreated NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlId, sleRapsRingControlType, sleRapsRingControlLevel, sleRapsRingControlCtrlVlan, sleRapsRingControlTrafficVlans } STATUS current DESCRIPTION "createRapsRing" ::= { sleRapsRingNotification 1 } sleRapsRingDeleted NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId } STATUS current DESCRIPTION "deleteRapsRing" ::= { sleRapsRingNotification 2 } sleRapsRingChannelChanged NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlChannel } STATUS current DESCRIPTION "setRapsRingChannel" ::= { sleRapsRingNotification 3 } sleRapsRingEnableChanged NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlEnable } STATUS current DESCRIPTION "setRapsRingEnable" ::= { sleRapsRingNotification 4 } sleRapsRingPortsCreated NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlEastPort, sleRapsRingControlWestPort, sleRapsRingControlParamPort } STATUS current DESCRIPTION "setRapsRingPorts" ::= { sleRapsRingNotification 5 } sleRapsRingPortsDestroyed NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId } STATUS current DESCRIPTION "destroyRapsRingPorts" ::= { sleRapsRingNotification 6 } sleRapsRingRplPortChanged NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlBridgeRole, sleRapsRingControlParamPort } STATUS current DESCRIPTION "setRapsRingRplPort" ::= { sleRapsRingNotification 7 } sleRapsRingIcPortCreated NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlIcNode, sleRapsRingControlParamPort, sleRapsRingControlInstId } STATUS current DESCRIPTION "setRapsRingIcPort" ::= { sleRapsRingNotification 8 } sleRapsRingIcPortDestroyed NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlId } STATUS current DESCRIPTION "destroyRapsRingIcPort" ::= { sleRapsRingNotification 9 } sleRapsRingMultipleFailureChanged NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlMultipleFailure } STATUS current DESCRIPTION "setRapsRingMultipleFailure" ::= { sleRapsRingNotification 10 } sleRapsRingPropagateTcChanged NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlPropagateTc } STATUS current DESCRIPTION "setRapsRingPropagateTc" ::= { sleRapsRingNotification 11 } sleRapsRingNonRevertiveChanged NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlNonRevertive } STATUS current DESCRIPTION "setRapsRingNonRevertive" ::= { sleRapsRingNotification 12 } sleRapsRingForcedSwitchChanged NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlParamPort } STATUS current DESCRIPTION "setRapsRingForcedSwitch" ::= { sleRapsRingNotification 13 } sleRapsRingManualSwitchChanged NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlParamPort } STATUS current DESCRIPTION "setRapsRingManualSwitch" ::= { sleRapsRingNotification 14 } sleRapsRingSwitchCleared NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId } STATUS current DESCRIPTION "setRapsRingClearSwitch" ::= { sleRapsRingNotification 15 } sleRapsRingHoldOffTimeChanged NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlHoldOffTime } STATUS current DESCRIPTION "setRapsRingHoldOffTime" ::= { sleRapsRingNotification 16 } sleRapsRingGuardTimeChanged NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlGuardTime } STATUS current DESCRIPTION "setRapsRingGuardTime" ::= { sleRapsRingNotification 17 } sleRapsRingWtrTimeChanged NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlWaitToRestore } STATUS current DESCRIPTION "setRapsRingWtrTime" ::= { sleRapsRingNotification 18 } sleRapsRingWtbTimeChanged NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlWaitToBlock } STATUS current DESCRIPTION "setRapsRingWtbTime" ::= { sleRapsRingNotification 19 } sleRapsRingPassThroughChanged NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlPassThrough } STATUS current DESCRIPTION "setRapsRingPassThrough" ::= { sleRapsRingNotification 20 } sleRapsRingVrfTimeChanged NOTIFICATION-TYPE OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlVerifiedTime } STATUS current DESCRIPTION "setRapsRingVrfTime" ::= { sleRapsRingNotification 21 } sleFaultMonitor OBJECT IDENTIFIER ::= { sleFaultMgmt 16 } sleFaultMonitorGlobal OBJECT IDENTIFIER ::= { sleFaultMonitor 1 } sleFaultMonitorGlobalBase OBJECT IDENTIFIER ::= { sleFaultMonitorGlobal 1 } sleFaultMonitorGlobalInspectInterval OBJECT-TYPE SYNTAX INTEGER (3..86400) MAX-ACCESS read-only STATUS current DESCRIPTION "daemon Inspection value. unit : sec, default : 5 " ::= { sleFaultMonitorGlobalBase 1 } sleFaultMonitorGlobalStartupThreshold OBJECT-TYPE SYNTAX INTEGER (100..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "daemon startup threshold value. unit : sec, default : 100 " ::= { sleFaultMonitorGlobalBase 2 } sleFaultMonitorGlobalNoKeepalive OBJECT-TYPE SYNTAX INTEGER { log(1), resetMate(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate action when don't receive keepalive msg. " ::= { sleFaultMonitorGlobalBase 3 } sleFaultMonitorGlobalControl OBJECT IDENTIFIER ::= { sleFaultMonitorGlobal 2 } sleFaultMonitorGlobalControlRequest OBJECT-TYPE SYNTAX INTEGER { setGlobalInspectInterval(1), setGlobalStartupThreshold(2), setNoKeepaliveAction(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sleFaultMonitorGlobalControl 1 } sleFaultMonitorGlobalControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION " The status of a control request. " ::= { sleFaultMonitorGlobalControl 2 } sleFaultMonitorGlobalControlTimer OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION " The maximum wait time for the manager for command ending. For long running commands. The manager reads this value from the DSLAM. " ::= { sleFaultMonitorGlobalControl 3 } sleFaultMonitorGlobalControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION " The time stamp of the last command (end of command). " ::= { sleFaultMonitorGlobalControl 4 } sleFaultMonitorGlobalControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION " The result of the last user command. " ::= { sleFaultMonitorGlobalControl 5 } sleFaultMonitorGlobalControlInspectInterval OBJECT-TYPE SYNTAX INTEGER (3..86400) MAX-ACCESS read-write STATUS current DESCRIPTION "daemon Inspection value. unit : sec, default : 5 " ::= { sleFaultMonitorGlobalControl 6 } sleFaultMonitorGlobalControlStartupThreshold OBJECT-TYPE SYNTAX INTEGER (100..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "daemon startup threshold value. unit : sec, default : 100 " ::= { sleFaultMonitorGlobalControl 7 } sleFaultMonitorGlobalControlNoKeepalive OBJECT-TYPE SYNTAX INTEGER { log(1), switchover(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicate action when don't receive keepalive msg. " ::= { sleFaultMonitorGlobalControl 8 } sleFaultMonitorGlobalNotification OBJECT IDENTIFIER ::= { sleFaultMonitorGlobal 3 } setFaultMonitorGlobalInspectIntervalChanged NOTIFICATION-TYPE OBJECTS { sleFaultMonitorGlobalControlRequest, sleFaultMonitorGlobalControlTimeStamp, sleFaultMonitorGlobalControlReqResult, sleFaultMonitorGlobalControlInspectInterval } STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorGlobalNotification 1 } setFaultMonitorGlobalStartupThresholdChanged NOTIFICATION-TYPE OBJECTS { sleFaultMonitorGlobalControlRequest, sleFaultMonitorGlobalControlTimeStamp, sleFaultMonitorGlobalControlReqResult, sleFaultMonitorGlobalControlStartupThreshold } STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorGlobalNotification 2 } setFaultMonitorGlobalNoKeepaliveActionChanged NOTIFICATION-TYPE OBJECTS { sleFaultMonitorGlobalControlRequest, sleFaultMonitorGlobalControlTimeStamp, sleFaultMonitorGlobalControlReqResult, sleFaultMonitorGlobalControlNoKeepalive } STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorGlobalNotification 3 } sleFaultMonitorDaemonConfig OBJECT IDENTIFIER ::= { sleFaultMonitor 2 } sleFaultMonitorDaemonTable OBJECT-TYPE SYNTAX SEQUENCE OF SleFaultMonitorDaemonEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorDaemonConfig 1 } sleFaultMonitorDaemonEntry OBJECT-TYPE SYNTAX SleFaultMonitorDaemonEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleFaultMonitorDaemonPid } ::= { sleFaultMonitorDaemonTable 1 } SleFaultMonitorDaemonEntry ::= SEQUENCE { sleFaultMonitorDaemonName OCTET STRING, sleFaultMonitorDaemonPid Integer32, sleFaultMonitorDaemonAdminStatus INTEGER, sleFaultMonitorDaemonCrashAction INTEGER, sleFaultMonitorDaemonTimeoutAction INTEGER, sleFaultMonitorDaemonThreshold Integer32, sleFaultMonitorDaemonThresholded Integer32, sleFaultMonitorDaemonStartupThresholded Integer32, sleFaultMonitorDaemonWatchdogAdminStatus INTEGER, sleFaultMonitorDaemonWatchdogThreshold Integer32, sleFaultMonitorDaemonWatchdogCount Integer32 } sleFaultMonitorDaemonName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Daemon name" ::= { sleFaultMonitorDaemonEntry 1 } sleFaultMonitorDaemonPid OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Daemon PID " ::= { sleFaultMonitorDaemonEntry 2 } sleFaultMonitorDaemonAdminStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Daemon Inspection admin status. " ::= { sleFaultMonitorDaemonEntry 3 } sleFaultMonitorDaemonCrashAction OBJECT-TYPE SYNTAX INTEGER { log(1), restart(2), switchover(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate action type when daemon is crashed " ::= { sleFaultMonitorDaemonEntry 4 } sleFaultMonitorDaemonTimeoutAction OBJECT-TYPE SYNTAX INTEGER { log(1), restart(2), switchover(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate action type when daemon is timeout " ::= { sleFaultMonitorDaemonEntry 5 } sleFaultMonitorDaemonThreshold OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate fault admin threshold. " ::= { sleFaultMonitorDaemonEntry 6 } sleFaultMonitorDaemonThresholded OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate fault accumulated threshold. " ::= { sleFaultMonitorDaemonEntry 7 } sleFaultMonitorDaemonStartupThresholded OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorDaemonEntry 8 } sleFaultMonitorDaemonWatchdogAdminStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate whether connect watchdog or not " ::= { sleFaultMonitorDaemonEntry 9 } sleFaultMonitorDaemonWatchdogThreshold OBJECT-TYPE SYNTAX Integer32 (5..60) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate watchdog threshold of daemon. " ::= { sleFaultMonitorDaemonEntry 10 } sleFaultMonitorDaemonWatchdogCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate watchdog accumulated count. " ::= { sleFaultMonitorDaemonEntry 11 } sleFaultMonitorDaemonControl OBJECT IDENTIFIER ::= { sleFaultMonitorDaemonConfig 2 } sleFaultMonitorDaemonControlRequest OBJECT-TYPE SYNTAX INTEGER { setDaemonAdminStatus(1), setDaemonFaultAction(2), setDaemonThreshold(3), setDaemonWatchdog(4) } MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sleFaultMonitorDaemonControl 1 } sleFaultMonitorDaemonControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION " The status of a control request. " ::= { sleFaultMonitorDaemonControl 2 } sleFaultMonitorDaemonControlTimer OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION " The maximum wait time for the manager for command ending. For long running commands. The manager reads this value from the DSLAM. " ::= { sleFaultMonitorDaemonControl 3 } sleFaultMonitorDaemonControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION " The time stamp of the last command (end of command). " ::= { sleFaultMonitorDaemonControl 4 } sleFaultMonitorDaemonControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION " The result of the last user command. " ::= { sleFaultMonitorDaemonControl 5 } sleFaultMonitorDaemonControlName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorDaemonControl 6 } sleFaultMonitorDaemonControlAdminStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "daemon Inspection value. unit : sec, default : 5 " ::= { sleFaultMonitorDaemonControl 7 } sleFaultMonitorDaemonControlCrashAction OBJECT-TYPE SYNTAX INTEGER { log(1), restart(2), switchover(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "daemon startup threshold value. unit : sec, default : 100 " ::= { sleFaultMonitorDaemonControl 8 } sleFaultMonitorDaemonControlTimeoutAction OBJECT-TYPE SYNTAX INTEGER { log(1), restart(2), switchover(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicate action when don't receive keepalive msg. " ::= { sleFaultMonitorDaemonControl 9 } sleFaultMonitorDaemonControlThreshold OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorDaemonControl 10 } sleFaultMonitorDaemonControlThreshed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorDaemonControl 11 } sleFaultMonitorDaemonControlStartupThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorDaemonControl 12 } sleFaultMonitorDaemonControlWatchdogAdminStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorDaemonControl 13 } sleFaultMonitorDaemonControlWatchdogThreshold OBJECT-TYPE SYNTAX Integer32 (5..60) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorDaemonControl 14 } sleFaultMonitorDaemonNotification OBJECT IDENTIFIER ::= { sleFaultMonitorDaemonConfig 4 } setFaultMonitorDaemonAdminStatusChanged NOTIFICATION-TYPE OBJECTS { sleFaultMonitorDaemonControlRequest, sleFaultMonitorDaemonControlTimeStamp, sleFaultMonitorDaemonControlReqResult, sleFaultMonitorDaemonControlAdminStatus } STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorDaemonNotification 1 } setFaultMonitorDaemonFaultActionChanged NOTIFICATION-TYPE OBJECTS { sleFaultMonitorDaemonControlRequest, sleFaultMonitorDaemonControlTimeStamp, sleFaultMonitorDaemonControlReqResult, sleFaultMonitorDaemonControlCrashAction, sleFaultMonitorDaemonControlTimeoutAction } STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorDaemonNotification 2 } setFaultMonitorDaemonThresholdChanged NOTIFICATION-TYPE OBJECTS { sleFaultMonitorDaemonControlRequest, sleFaultMonitorDaemonControlTimeStamp, sleFaultMonitorDaemonControlReqResult, sleFaultMonitorDaemonControlThreshold } STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorDaemonNotification 3 } setFaultMonitorDaemonWatchdogchanged NOTIFICATION-TYPE OBJECTS { sleFaultMonitorDaemonControlRequest, sleFaultMonitorDaemonControlTimeStamp, sleFaultMonitorDaemonControlReqResult, sleFaultMonitorDaemonControlWatchdogAdminStatus, sleFaultMonitorDaemonControlWatchdogThreshold } STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorDaemonNotification 4 } sleFaultMonitor2pointsLinear OBJECT IDENTIFIER ::= { sleFaultMonitor 3 } sleFaultMonitor2pointsLinearInfo OBJECT IDENTIFIER ::= { sleFaultMonitor2pointsLinear 1 } sleFaultMonitor2pointsLinearAdminStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate whether 2-points-linear monitoring is enabled or not " ::= { sleFaultMonitor2pointsLinearInfo 1 } sleFaultMonitor2pointsLinearInterval OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate 2-points-linear monitoring interval default : 5, unit : sec " ::= { sleFaultMonitor2pointsLinearInfo 2 } sleFaultMonitor2pointsLinearThreshold OBJECT-TYPE SYNTAX Integer32 (1..60) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate 2-points-linear monitoring threshold default : 8 times " ::= { sleFaultMonitor2pointsLinearInfo 3 } sleFaultMonitor2pointsLinearControl OBJECT IDENTIFIER ::= { sleFaultMonitor2pointsLinear 2 } sleFaultMonitor2pointsLinearControlRequest OBJECT-TYPE SYNTAX INTEGER { set2PointsLinearAdminStatus(1), set2PointsLinearInterval(2), set2PointsLinearThreshold(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sleFaultMonitor2pointsLinearControl 1 } sleFaultMonitor2pointsLinearControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION " The status of a control request. " ::= { sleFaultMonitor2pointsLinearControl 2 } sleFaultMonitor2pointsLinearControlTimer OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION " The maximum wait time for the manager for command ending. For long running commands. The manager reads this value from the DSLAM. " ::= { sleFaultMonitor2pointsLinearControl 3 } sleFaultMonitor2pointsLinearControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION " The time stamp of the last command (end of command). " ::= { sleFaultMonitor2pointsLinearControl 4 } sleFaultMonitor2pointsLinearControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION " The result of the last user command. " ::= { sleFaultMonitor2pointsLinearControl 5 } sleFaultMonitor2pointsLinearControlAdminStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sleFaultMonitor2pointsLinearControl 6 } sleFaultMonitor2PonitsLinearControlInterval OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicate 2-points-linear monitoring interval default : 5, unit : sec" ::= { sleFaultMonitor2pointsLinearControl 7 } sleFaultMonitor2PointsLinearControlThreshold OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicate 2-points-linear monitoring threshold default : 8 times " ::= { sleFaultMonitor2pointsLinearControl 8 } sleFaultMonitor2pointsLinearNotification OBJECT IDENTIFIER ::= { sleFaultMonitor2pointsLinear 3 } sleFaultMonitor2PointsLinearAdminStatusChanged NOTIFICATION-TYPE OBJECTS { sleFaultMonitor2pointsLinearControlRequest, sleFaultMonitor2pointsLinearControlTimeStamp, sleFaultMonitor2pointsLinearControlReqResult, sleFaultMonitor2pointsLinearControlAdminStatus } STATUS current DESCRIPTION "Description." ::= { sleFaultMonitor2pointsLinearNotification 1 } sleFaultMonitor2PointsLinearIntervalChanged NOTIFICATION-TYPE OBJECTS { sleFaultMonitor2pointsLinearControlRequest, sleFaultMonitor2pointsLinearControlTimeStamp, sleFaultMonitor2pointsLinearControlReqResult, sleFaultMonitor2PonitsLinearControlInterval } STATUS current DESCRIPTION "Description." ::= { sleFaultMonitor2pointsLinearNotification 2 } sleFaultMonitor2PointsLinearThresholdChanged NOTIFICATION-TYPE OBJECTS { sleFaultMonitor2pointsLinearControlRequest, sleFaultMonitor2pointsLinearControlTimeStamp, sleFaultMonitor2pointsLinearControlReqResult, sleFaultMonitor2PointsLinearControlThreshold } STATUS current DESCRIPTION "Description." ::= { sleFaultMonitor2pointsLinearNotification 3 } sleFaultMonitorRHM OBJECT IDENTIFIER ::= { sleFaultMonitor 4 } sleFaultMonitorRHMInfo OBJECT IDENTIFIER ::= { sleFaultMonitorRHM 1 } sleFaultMonitorRHMAdminStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The RHM admin status" ::= { sleFaultMonitorRHMInfo 1 } sleFaultMonitorRHMActionType OBJECT-TYPE SYNTAX INTEGER { log(1), switchover(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The RHM action type " ::= { sleFaultMonitorRHMInfo 2 } sleFaultMonitorRHMActionThreshold OBJECT-TYPE SYNTAX Integer32 (5..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "The RHM action threshold " ::= { sleFaultMonitorRHMInfo 3 } sleFaultMonitorRHMRebootThreshold OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The RHM reboot threshold" ::= { sleFaultMonitorRHMInfo 4 } sleFaultMonitorRHMRecoveryTime OBJECT-TYPE SYNTAX Integer32 (10..14400) MAX-ACCESS read-only STATUS current DESCRIPTION "The RHM recovery time" ::= { sleFaultMonitorRHMInfo 5 } sleFaultMonitorRHMFaultCounter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The RHM fault counter" ::= { sleFaultMonitorRHMInfo 6 } sleFaultMonitorRHMRebootCounter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The RHM reboot counter" ::= { sleFaultMonitorRHMInfo 7 } sleFaultMonitorRHMInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorRHMInfo 8 } sleFaultMonitorRHMLiveThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorRHMInfo 9 } sleFaultMonitorRHMHostTable OBJECT-TYPE SYNTAX SEQUENCE OF SleFaultMonitorRHMHostEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorRHM 2 } sleFaultMonitorRHMHostEntry OBJECT-TYPE SYNTAX SleFaultMonitorRHMHostEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sleFaultMonitorRHMHostAddr } ::= { sleFaultMonitorRHMHostTable 1 } SleFaultMonitorRHMHostEntry ::= SEQUENCE { sleFaultMonitorRHMHostAddr IpAddress } sleFaultMonitorRHMHostAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The target host or gateway address of RHM " ::= { sleFaultMonitorRHMHostEntry 1 } sleFaultMonitorRHMControl OBJECT IDENTIFIER ::= { sleFaultMonitorRHM 3 } sleFaultMonitorRHMControlRequest OBJECT-TYPE SYNTAX INTEGER { setRHMStatus(1), setRHMActionThreshold(2), setRHMRebootThreshold(3), setInterval(4), setLiveThreshold(5), clearRHMHost(6), setRHMHost(7) } MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sleFaultMonitorRHMControl 1 } sleFaultMonitorRHMControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION " The status of a control request. " ::= { sleFaultMonitorRHMControl 2 } sleFaultMonitorRHMControlTimer OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION " The maximum wait time for the manager for command ending. For long running commands. The manager reads this value from the DSLAM. " ::= { sleFaultMonitorRHMControl 3 } sleFaultMonitorRHMControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION " The time stamp of the last command (end of command). " ::= { sleFaultMonitorRHMControl 4 } sleFaultMonitorRHMControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION " The result of the last user command. " ::= { sleFaultMonitorRHMControl 5 } sleFaultMonitorRHMControlAdminStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sleFaultMonitorRHMControl 6 } sleFaultMonitorRHMControlActionType OBJECT-TYPE SYNTAX INTEGER { log(1), switchover(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicate 2-points-linear monitoring interval default : 5, unit : sec" ::= { sleFaultMonitorRHMControl 7 } sleFaultMonitorRHMControlActionThreshold OBJECT-TYPE SYNTAX Integer32 (5..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "The RHM reboot threshold" ::= { sleFaultMonitorRHMControl 8 } sleFaultMonitorRHMControlRebootThreshold OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "The RHM reboot threshold" ::= { sleFaultMonitorRHMControl 9 } sleFaultMonitorRHMControlRecoveryTime OBJECT-TYPE SYNTAX Integer32 (10..14400) MAX-ACCESS read-write STATUS current DESCRIPTION "The RHM recovery time" ::= { sleFaultMonitorRHMControl 10 } sleFaultMonitorRHMControlInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorRHMControl 11 } sleFaultMonitorRHMControlLiveThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorRHMControl 12 } sleFaultMonitorRHMControlHostAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorRHMControl 13 } sleFaultMonitorRHMNotification OBJECT IDENTIFIER ::= { sleFaultMonitorRHM 4 } setRHMStatusChanged NOTIFICATION-TYPE OBJECTS { sleFaultMonitorRHMControlRequest, sleFaultMonitorRHMControlTimeStamp, sleFaultMonitorRHMControlReqResult, sleFaultMonitorRHMControlAdminStatus, sleFaultMonitorRHMControlActionType } STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorRHMNotification 1 } setRHMActionThresholdChanged NOTIFICATION-TYPE OBJECTS { sleFaultMonitorRHMControlRequest, sleFaultMonitorRHMControlTimeStamp, sleFaultMonitorRHMControlReqResult, sleFaultMonitorRHMControlActionThreshold } STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorRHMNotification 2 } setRHMRebootThresholdChanged NOTIFICATION-TYPE OBJECTS { sleFaultMonitorRHMControlRequest, sleFaultMonitorRHMControlTimeStamp, sleFaultMonitorRHMControlReqResult, sleFaultMonitorRHMControlRebootThreshold } STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorRHMNotification 3 } setRHMHostAdded NOTIFICATION-TYPE OBJECTS { sleFaultMonitorRHMControlRequest, sleFaultMonitorRHMControlTimeStamp, sleFaultMonitorRHMControlReqResult, sleFaultMonitorRHMControlRebootThreshold } STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorRHMNotification 4 } setRHMHostCleared NOTIFICATION-TYPE OBJECTS { sleFaultMonitorRHMControlRequest, sleFaultMonitorRHMControlTimeStamp, sleFaultMonitorRHMControlReqResult, sleFaultMonitorRHMControlRebootThreshold } STATUS current DESCRIPTION "Description." ::= { sleFaultMonitorRHMNotification 5 } sle2EthernetCfm OBJECT IDENTIFIER ::= { sleFaultMgmt 17 } sle2EthernetCfmBase OBJECT IDENTIFIER ::= { sle2EthernetCfm 1 } sle2EthCfmBaseGroup OBJECT IDENTIFIER ::= { sle2EthernetCfmBase 1 } sle2EthCfmEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBaseGroup 1 } sle2EthCfmLmmFrameCountSimStatus OBJECT-TYPE SYNTAX INTEGER { stop(0), start(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBaseGroup 2 } sle2EthCfmBaseControl OBJECT IDENTIFIER ::= { sle2EthernetCfmBase 2 } sle2EthCfmControlRequest OBJECT-TYPE SYNTAX INTEGER { setCfmEnable(1), setCfmLmmSimulator(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBaseControl 1 } sle2EthCfmControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBaseControl 2 } sle2EthCfmControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBaseControl 3 } sle2EthCfmControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBaseControl 4 } sle2EthCfmControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBaseControl 5 } sle2EthCfmControlEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBaseControl 6 } sle2EthCfmControlLmmFrameCountSimStatus OBJECT-TYPE SYNTAX INTEGER { stop(0), start(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBaseControl 7 } sle2EthCfmBaseNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmBase 3 } sle2EthCfmEnableChanged NOTIFICATION-TYPE OBJECTS { sle2EthCfmControlRequest, sle2EthCfmControlReqResult, sle2EthCfmControlTimeStamp, sle2EthCfmEnable } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBaseNotification 1 } sle2EthCfmLmmFrameCountSimulatorChanged NOTIFICATION-TYPE OBJECTS { sle2EthCfmControlRequest, sle2EthCfmControlReqResult, sle2EthCfmControlTimeStamp, sle2EthCfmLmmFrameCountSimStatus } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBaseNotification 2 } sle2EthernetCfmBridge OBJECT IDENTIFIER ::= { sle2EthernetCfm 2 } sle2EthCfmBridgeTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmBridgeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmBridge 1 } sle2EthCfmBridgeEntry OBJECT-TYPE SYNTAX Sle2EthCfmBridgeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId } ::= { sle2EthCfmBridgeTable 1 } Sle2EthCfmBridgeEntry ::= SEQUENCE { sle2EthCfmBridgeId Integer32, sle2EthCfmBridgeDefaultMdLevel Integer32, sle2EthCfmBridgeDefaultMepId Integer32, sle2EthCfmBridgeAutomatic INTEGER, sle2EthCfmBridgeConfigDefaultMdLevel Integer32, sle2EthCfmBridgeConfigDefaultMdMipCreation INTEGER, sle2EthCfmBridgeLtrCacheEnable INTEGER, sle2EthCfmBridgeLtrCacheSize Integer32 } sle2EthCfmBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32 | 100) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeEntry 1 } sle2EthCfmBridgeDefaultMdLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeEntry 2 } sle2EthCfmBridgeDefaultMepId OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeEntry 3 } sle2EthCfmBridgeAutomatic OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeEntry 4 } sle2EthCfmBridgeConfigDefaultMdLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeEntry 5 } sle2EthCfmBridgeConfigDefaultMdMipCreation OBJECT-TYPE SYNTAX INTEGER { none(1), default(2), explicit(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeEntry 6 } sle2EthCfmBridgeLtrCacheEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeEntry 7 } sle2EthCfmBridgeLtrCacheSize OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeEntry 8 } sle2EthCfmBridgeControl OBJECT IDENTIFIER ::= { sle2EthernetCfmBridge 2 } sle2EthCfmBridgeControlRequest OBJECT-TYPE SYNTAX INTEGER { setCfmBridgeProfile(1), setCfmBridgeLtrCache(2), clearCfmBridgeLtrChace(3), setCfmBridgeAutomatic(4), setCfmBridgeConfigDefaultMdLevel(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeControl 1 } sle2EthCfmBridgeControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeControl 2 } sle2EthCfmBridgeControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeControl 3 } sle2EthCfmBridgeControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeControl 4 } sle2EthCfmBridgeControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeControl 5 } sle2EthCfmBridgeControlId OBJECT-TYPE SYNTAX Integer32 (1..32 | 100) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeControl 6 } sle2EthCfmBridgeControlDefaultMdLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeControl 7 } sle2EthCfmBridgeControlDefaultMepId OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeControl 8 } sle2EthCfmBridgeControlAutomatic OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeControl 9 } sle2EthCfmBridgeControlConfigDefaultMdLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeControl 10 } sle2EthCfmBridgeControlConfigDefaultMdMipCreation OBJECT-TYPE SYNTAX INTEGER { none(1), default(2), explicit(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeControl 11 } sle2EthCfmBridgeConntrolLtrCacheEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeControl 12 } sle2EthCfmBridgeControlLtrCacheSize OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeControl 13 } sle2EthCfmBridgeNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmBridge 3 } setCfmBridgeProfile NOTIFICATION-TYPE OBJECTS { sle2EthCfmBridgeControlRequest, sle2EthCfmBridgeControlReqResult, sle2EthCfmBridgeControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmBridgeDefaultMdLevel, sle2EthCfmBridgeDefaultMepId } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeNotification 1 } setCfmBridgeLtrCacheEnable NOTIFICATION-TYPE OBJECTS { sle2EthCfmBridgeControlRequest, sle2EthCfmBridgeControlReqResult, sle2EthCfmBridgeControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmBridgeLtrCacheSize, sle2EthCfmBridgeLtrCacheEnable } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeNotification 2 } clearCfmBridgeLtrCache NOTIFICATION-TYPE OBJECTS { sle2EthCfmBridgeControlRequest, sle2EthCfmBridgeControlReqResult, sle2EthCfmBridgeControlTimeStamp, sle2EthCfmBridgeId } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeNotification 3 } setCfmBridgeAutomatic NOTIFICATION-TYPE OBJECTS { sle2EthCfmBridgeControlRequest, sle2EthCfmBridgeControlReqResult, sle2EthCfmBridgeControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmBridgeAutomatic } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeNotification 4 } setCfmBridgeConfigDefaultMdLevel NOTIFICATION-TYPE OBJECTS { sle2EthCfmBridgeControlRequest, sle2EthCfmBridgeControlReqResult, sle2EthCfmBridgeControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmBridgeConfigDefaultMdLevel, sle2EthCfmBridgeConfigDefaultMdMipCreation } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmBridgeNotification 5 } sle2EhternetCfmVlan OBJECT IDENTIFIER ::= { sle2EthernetCfm 3 } sle2EthernetCfmVlanConfig OBJECT IDENTIFIER ::= { sle2EhternetCfmVlan 1 } sle2EthCfmVlanConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmVlanConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmVlanConfig 1 } sle2EthCfmVlanConfigEntry OBJECT-TYPE SYNTAX Sle2EthCfmVlanConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId, sle2EthCfmVlanConfigPrimaryVid, sle2EthCfmVlanConfigSecondaryVid } ::= { sle2EthCfmVlanConfigTable 1 } Sle2EthCfmVlanConfigEntry ::= SEQUENCE { sle2EthCfmVlanConfigPrimaryVid Integer32, sle2EthCfmVlanConfigSecondaryVid Integer32, sle2EthCfmVlanConfigSecondaryBridgeId Integer32 } sle2EthCfmVlanConfigPrimaryVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanConfigEntry 1 } sle2EthCfmVlanConfigSecondaryVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanConfigEntry 2 } sle2EthCfmVlanConfigSecondaryBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32 | 100) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanConfigEntry 3 } sle2EthCfmVlanConfigControl OBJECT IDENTIFIER ::= { sle2EthernetCfmVlanConfig 2 } sle2EthCfmVlanConfigControlRequest OBJECT-TYPE SYNTAX INTEGER { addCfmVlanConfVid(1), delCfmVlanConfVid(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanConfigControl 1 } sle2EthCfmVlanConfigControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanConfigControl 2 } sle2EthCfmVlanConfigControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanConfigControl 3 } sle2EthCfmVlanConfigControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanConfigControl 4 } sle2EthCfmVlanConfigControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanConfigControl 5 } sle2EthCfmVlanConfigControlPrimaryBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32 | 100) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanConfigControl 6 } sle2EthCfmVlanConfigControlPrimaryVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanConfigControl 7 } sle2EthCfmVlanConfigControlSecondaryBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32 | 100) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanConfigControl 8 } sle2EthCfmVlanConfigControlSecondaryVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanConfigControl 9 } sle2EthCfmVlanConfigNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmVlanConfig 3 } addCfmVlanConfVid NOTIFICATION-TYPE OBJECTS { sle2EthCfmVlanConfigControlRequest, sle2EthCfmVlanConfigControlReqResult, sle2EthCfmVlanConfigControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmVlanConfigPrimaryVid, sle2EthCfmVlanConfigSecondaryVid, sle2EthCfmVlanConfigSecondaryBridgeId } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanConfigNotification 1 } delCfmVlanConfVid NOTIFICATION-TYPE OBJECTS { sle2EthCfmVlanConfigControlRequest, sle2EthCfmVlanConfigControlReqResult, sle2EthCfmVlanConfigControlTimeStamp, sle2EthCfmVlanConfigControlPrimaryBridgeId, sle2EthCfmVlanConfigControlPrimaryVid, sle2EthCfmVlanConfigControlSecondaryBridgeId, sle2EthCfmVlanConfigControlSecondaryVid } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanConfigNotification 2 } sle2EthernetCfmVlanInfo OBJECT IDENTIFIER ::= { sle2EhternetCfmVlan 2 } sle2EthCfmVlanInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmVlanInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmVlanInfo 1 } sle2EthCfmVlanInfoEntry OBJECT-TYPE SYNTAX Sle2EthCfmVlanInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId, sle2EthCfmVlanInfoVid } ::= { sle2EthCfmVlanInfoTable 1 } Sle2EthCfmVlanInfoEntry ::= SEQUENCE { sle2EthCfmVlanInfoVid Integer32, sle2EthCfmVlanInfoPriority Integer32 } sle2EthCfmVlanInfoVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanInfoEntry 1 } sle2EthCfmVlanInfoPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanInfoEntry 2 } sle2EthCfmVlanInfoControl OBJECT IDENTIFIER ::= { sle2EthernetCfmVlanInfo 2 } sle2EthCfmVlanInfoControlRequest OBJECT-TYPE SYNTAX INTEGER { setCfmVlanPriority(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanInfoControl 1 } sle2EthCfmVlanInfoControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanInfoControl 2 } sle2EthCfmVlanInfoControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanInfoControl 3 } sle2EthCfmVlanInfoControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanInfoControl 4 } sle2EthCfmVlanInfoControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanInfoControl 5 } sle2EthCfmVlanInfoControlBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanInfoControl 6 } sle2EthCfmVlanInfoControlVid OBJECT-TYPE SYNTAX Integer32 (2..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanInfoControl 7 } sle2EthCfmVlanInfoControlPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanInfoControl 8 } sle2EthCfmVlanInfoNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmVlanInfo 3 } sle2EthCfmVlanPriorityChanged NOTIFICATION-TYPE OBJECTS { sle2EthCfmVlanInfoControlRequest, sle2EthCfmVlanInfoControlReqResult, sle2EthCfmVlanInfoControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmVlanInfoVid, sle2EthCfmVlanInfoPriority } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmVlanInfoNotification 1 } sle2EthernetCfmDefMdLevelEntry OBJECT IDENTIFIER ::= { sle2EthernetCfm 4 } sle2EthCfmDefMdLevelEntryTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmDefMdLevelEntryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmDefMdLevelEntry 1 } sle2EthCfmDefMdLevelEntryEntry OBJECT-TYPE SYNTAX Sle2EthCfmDefMdLevelEntryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId, sle2EthCfmDefMdLevelEntryVid } ::= { sle2EthCfmDefMdLevelEntryTable 1 } Sle2EthCfmDefMdLevelEntryEntry ::= SEQUENCE { sle2EthCfmDefMdLevelEntryVid Integer32, sle2EthCfmDefMdLevelEntryLevel Integer32, sle2EthCfmDefMdLevelEntryMipCreation INTEGER } sle2EthCfmDefMdLevelEntryVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmDefMdLevelEntryEntry 1 } sle2EthCfmDefMdLevelEntryLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmDefMdLevelEntryEntry 2 } sle2EthCfmDefMdLevelEntryMipCreation OBJECT-TYPE SYNTAX INTEGER { none(1), default(2), explicit(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmDefMdLevelEntryEntry 3 } sle2EthCfmDefMdLevelEntryControl OBJECT IDENTIFIER ::= { sle2EthernetCfmDefMdLevelEntry 2 } sle2EthCfmDefMdLevelEntryControlRequest OBJECT-TYPE SYNTAX INTEGER { setCfmDefMdLevelEntry(1), clearCfmDefMdLevelEntry(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmDefMdLevelEntryControl 1 } sle2EthCfmDefMdLevelEntryControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmDefMdLevelEntryControl 2 } sle2EthCfmDefMdLevelEntryControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmDefMdLevelEntryControl 3 } sle2EthCfmDefMdLevelEntryControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmDefMdLevelEntryControl 4 } sle2EthCfmDefMdLevelEntryControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmDefMdLevelEntryControl 5 } sle2EthCfmDefMdLevelEntryControlBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32 | 100) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmDefMdLevelEntryControl 6 } sle2EthCfmDefMdLevelEntryControlVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmDefMdLevelEntryControl 7 } sle2EthCfmDefMdLevelEntryControlLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmDefMdLevelEntryControl 8 } sle2EthCfmDefMdLevelEntryControlMipCreation OBJECT-TYPE SYNTAX INTEGER { none(1), default(2), explicit(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmDefMdLevelEntryControl 9 } sle2EthCfmDefMdLevelEntryNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmDefMdLevelEntry 3 } sle2EthCfmDefMdLevelEntryChanged NOTIFICATION-TYPE OBJECTS { sle2EthCfmDefMdLevelEntryControlRequest, sle2EthCfmDefMdLevelEntryControlReqResult, sle2EthCfmDefMdLevelEntryControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmDefMdLevelEntryVid, sle2EthCfmDefMdLevelEntryLevel, sle2EthCfmDefMdLevelEntryMipCreation } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmDefMdLevelEntryNotification 1 } sle2EthCfmDefMdLevelEntryCleared NOTIFICATION-TYPE OBJECTS { sle2EthCfmDefMdLevelEntryControlRequest, sle2EthCfmDefMdLevelEntryControlReqResult, sle2EthCfmDefMdLevelEntryControlTimeStamp, sle2EthCfmDefMdLevelEntryControlBridgeId, sle2EthCfmDefMdLevelEntryControlVid, sle2EthCfmDefMdLevelEntryControlLevel, sle2EthCfmDefMdLevelEntryControlMipCreation } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmDefMdLevelEntryNotification 2 } sle2EthernetCfmMd OBJECT IDENTIFIER ::= { sle2EthernetCfm 5 } sle2EthCfmMdTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmMdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmMd 1 } sle2EthCfmMdEntry OBJECT-TYPE SYNTAX Sle2EthCfmMdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName } ::= { sle2EthCfmMdTable 1 } Sle2EthCfmMdEntry ::= SEQUENCE { sle2EthCfmMdName OCTET STRING, sle2EthCfmMdType INTEGER, sle2EthCfmMdLevel Integer32, sle2EthCfmMdMipCreation INTEGER } sle2EthCfmMdName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMdEntry 1 } sle2EthCfmMdType OBJECT-TYPE SYNTAX INTEGER { noName(1), dnsBased(2), mac(3), characterString(4), ituT(32) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMdEntry 2 } sle2EthCfmMdLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMdEntry 3 } sle2EthCfmMdMipCreation OBJECT-TYPE SYNTAX INTEGER { none(1), default(2), explicit(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMdEntry 4 } sle2EthCfmMdControl OBJECT IDENTIFIER ::= { sle2EthernetCfmMd 2 } sle2EthCfmMdControlRequest OBJECT-TYPE SYNTAX INTEGER { createCfmMd(1), destoryCfmMd(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMdControl 1 } sle2EthCfmMdControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMdControl 2 } sle2EthCfmMdControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMdControl 3 } sle2EthCfmMdControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMdControl 4 } sle2EthCfmMdControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMdControl 5 } sle2EthCfmMdControlBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMdControl 6 } sle2EthCfmMdControlType OBJECT-TYPE SYNTAX INTEGER { noName(1), dnsBased(2), mac(3), characterString(4), ituT(32) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMdControl 7 } sle2EthCfmMdControlName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMdControl 8 } sle2EthCfmMdControlLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMdControl 9 } sle2EthCfmMdControlMipCreation OBJECT-TYPE SYNTAX INTEGER { none(1), default(2), explicit(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMdControl 10 } sle2EthCfmMdNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmMd 3 } sle2EthCfmMdCreated NOTIFICATION-TYPE OBJECTS { sle2EthCfmMdControlRequest, sle2EthCfmMdControlReqResult, sle2EthCfmMdControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMdType, sle2EthCfmMdLevel, sle2EthCfmMdMipCreation } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMdNotification 1 } sle2EthCfmMdDestoryed NOTIFICATION-TYPE OBJECTS { sle2EthCfmMdControlRequest, sle2EthCfmMdControlReqResult, sle2EthCfmMdControlTimeStamp, sle2EthCfmMdControlBridgeId, sle2EthCfmMdControlName, sle2EthCfmMdControlLevel, sle2EthCfmMdControlMipCreation } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMdNotification 2 } sle2EthernetCfmMa OBJECT IDENTIFIER ::= { sle2EthernetCfm 6 } sle2EthCfmMaTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmMaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmMa 1 } sle2EthCfmMaEntry OBJECT-TYPE SYNTAX Sle2EthCfmMaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaName } ::= { sle2EthCfmMaTable 1 } Sle2EthCfmMaEntry ::= SEQUENCE { sle2EthCfmMaName OCTET STRING, sle2EthCfmMaVid Integer32, sle2EthCfmMaType INTEGER, sle2EthCfmMaMipCreation INTEGER, sle2EthCfmMaCcInterval Integer32, sle2EthCfmMaElmi INTEGER, sle2EthCfmMaConnectivityStatus INTEGER, sle2EthCfmMaConfiguredRmepCount Integer32, sle2EthCfmMaConvergedRmepCount Integer32 } sle2EthCfmMaName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaEntry 1 } sle2EthCfmMaVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaEntry 2 } sle2EthCfmMaType OBJECT-TYPE SYNTAX INTEGER { primaryVid(1), string(2), integer(3), vpnId(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaEntry 3 } sle2EthCfmMaMipCreation OBJECT-TYPE SYNTAX INTEGER { none(1), default(2), explicit(3), defer(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaEntry 4 } sle2EthCfmMaCcInterval OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaEntry 5 } sle2EthCfmMaElmi OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaEntry 6 } sle2EthCfmMaConnectivityStatus OBJECT-TYPE SYNTAX INTEGER { unknow(1), active(2), partiallyActive(3), notActive(4), error(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaEntry 7 } sle2EthCfmMaConfiguredRmepCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaEntry 8 } sle2EthCfmMaConvergedRmepCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaEntry 9 } sle2EthCfmMaControl OBJECT IDENTIFIER ::= { sle2EthernetCfmMa 2 } sle2EthCfmMaControlRequest OBJECT-TYPE SYNTAX INTEGER { createCfmMa(1), destoryCfmMa(2), setCfmCcInterval(3), setCfmElmi(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaControl 1 } sle2EthCfmMaControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaControl 2 } sle2EthCfmMaControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaControl 3 } sle2EthCfmMaControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaControl 4 } sle2EthCfmMaControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaControl 5 } sle2EthCfmMaControlBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaControl 6 } sle2EthCfmMaControlMdName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaControl 7 } sle2EthCfmMaControlName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaControl 8 } sle2EthCfmMaControlType OBJECT-TYPE SYNTAX INTEGER { primaryVid(1), string(2), integer(3), vpnId(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaControl 9 } sle2EthCfmMaControlVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaControl 10 } sle2EthCfmMaControlMipCreation OBJECT-TYPE SYNTAX INTEGER { none(1), default(2), explicit(3), defer(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaControl 11 } sle2EthCfmMaControlCcmInterval OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaControl 12 } sle2EthCfmMaControlElmi OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaControl 13 } sle2EthCfmMaNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmMa 3 } sle2EthCfmMaCreated NOTIFICATION-TYPE OBJECTS { sle2EthCfmMaControlRequest, sle2EthCfmMaControlReqResult, sle2EthCfmMaControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaName, sle2EthCfmMaVid, sle2EthCfmMaType, sle2EthCfmMaMipCreation } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaNotification 1 } sle2EthCfmMaDestoryed NOTIFICATION-TYPE OBJECTS { sle2EthCfmMaControlRequest, sle2EthCfmMaControlReqResult, sle2EthCfmMaControlTimeStamp, sle2EthCfmMaControlBridgeId, sle2EthCfmMaControlMdName, sle2EthCfmMaControlName, sle2EthCfmMaControlVid, sle2EthCfmMaControlMipCreation } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaNotification 2 } sle2EthCfmCcIntervalChanged NOTIFICATION-TYPE OBJECTS { sle2EthCfmMaControlRequest, sle2EthCfmMaControlReqResult, sle2EthCfmMaControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMaCcInterval } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaNotification 3 } sle2EthCfmElmiChanged NOTIFICATION-TYPE OBJECTS { sle2EthCfmMaControlRequest, sle2EthCfmMaControlReqResult, sle2EthCfmMaControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaName, sle2EthCfmMaElmi } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMaNotification 4 } sle2EthernetCfmMep OBJECT IDENTIFIER ::= { sle2EthernetCfm 7 } sle2EthernetCfmMepInfo OBJECT IDENTIFIER ::= { sle2EthernetCfmMep 1 } sle2EthCfmMepInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmMepInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmMepInfo 1 } sle2EthCfmMepInfoEntry OBJECT-TYPE SYNTAX Sle2EthCfmMepInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId } ::= { sle2EthCfmMepInfoTable 1 } Sle2EthCfmMepInfoEntry ::= SEQUENCE { sle2EthCfmMepInfoId Integer32, sle2EthCfmMepInfoIfindex Integer32, sle2EthCfmMepInfoLocalVid Integer32, sle2EthCfmMepInfoDirection INTEGER, sle2EthCfmMepInfoActive INTEGER, sle2EthCfmMepInfoUNI INTEGER, sle2EthCfmMepInfoCcmStatus INTEGER, sle2EthCfmMepInfoCcmType INTEGER, sle2EthCfmMepInfoCcmRmepId Integer32, sle2EthCfmMepInfoLocalMacAddr OCTET STRING, sle2EthCfmMepInfoRdi INTEGER, sle2EthCfmMepInfoService INTEGER, sle2EthCfmMepInfoLckLevel Integer32, sle2EthCfmMepInfoDlmState INTEGER, sle2EthCfmMepInfoDlmRmepId Integer32, sle2EthCfmMepInfoConnectivityStatus INTEGER, sle2EthCfmMepInfoInterval Integer32 } sle2EthCfmMepInfoId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoEntry 1 } sle2EthCfmMepInfoIfindex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoEntry 2 } sle2EthCfmMepInfoLocalVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoEntry 3 } sle2EthCfmMepInfoDirection OBJECT-TYPE SYNTAX INTEGER { down(1), up(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoEntry 4 } sle2EthCfmMepInfoActive OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoEntry 5 } sle2EthCfmMepInfoUNI OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoEntry 6 } sle2EthCfmMepInfoCcmStatus OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoEntry 7 } sle2EthCfmMepInfoCcmType OBJECT-TYPE SYNTAX INTEGER { unicast(1), multicast(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoEntry 8 } sle2EthCfmMepInfoCcmRmepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoEntry 9 } sle2EthCfmMepInfoLocalMacAddr OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoEntry 10 } sle2EthCfmMepInfoRdi OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoEntry 11 } sle2EthCfmMepInfoService OBJECT-TYPE SYNTAX INTEGER { inService(0), outOfService(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoEntry 12 } sle2EthCfmMepInfoLckLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoEntry 13 } sle2EthCfmMepInfoDlmState OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoEntry 14 } sle2EthCfmMepInfoDlmRmepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoEntry 15 } sle2EthCfmMepInfoConnectivityStatus OBJECT-TYPE SYNTAX INTEGER { none(0), isolated(1), fully(2), partially(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoEntry 16 } sle2EthCfmMepInfoInterval OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoEntry 17 } sle2EthCfmMepInfoControl OBJECT IDENTIFIER ::= { sle2EthernetCfmMepInfo 2 } sle2EthCfmMepInfoControlRequest OBJECT-TYPE SYNTAX INTEGER { createEthCfmMep(1), destoryEthCfmMep(2), setEthCfmCcEnable(3), setEthCfmService(4), setEthCfmDlmm(5), tarnsmitUnicastTst(6), tarnsmitMulticastTst(7), transmitUnicastLm(8), transmitMulticastLm(9), transmitUnicastDm(10), transmitMulticastDm(11), receive1Dm(12), transmitTm(13), receiveTm(14), transmitExm(15), transmitVsm(16), transmitMcc(17) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 1 } sle2EthCfmMepInfoControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 2 } sle2EthCfmMepInfoControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 3 } sle2EthCfmMepInfoControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 4 } sle2EthCfmMepInfoControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 5 } sle2EthCfmMepInfoControlBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 6 } sle2EthCfmMepInfoControlMdName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 7 } sle2EthCfmMepInfoControlMaVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 8 } sle2EthCfmMepInfoControlIfindex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 9 } sle2EthCfmMepInfoControlId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 10 } sle2EthCfmMepInfoControlLocalVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 11 } sle2EthCfmMepInfoControlMepDirection OBJECT-TYPE SYNTAX INTEGER { down(1), up(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 12 } sle2EthCfmMepInfoControlActive OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 13 } sle2EthCfmMepInfoControlUNI OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 14 } sle2EthCfmMepInfoControlCcmStatus OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 15 } sle2EthCfmMepInfoControlFrameType OBJECT-TYPE SYNTAX INTEGER { unicast(1), multicast(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 16 } sle2EthCfmMepInfoControlRmepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 17 } sle2EthCfmMepInfoControlService OBJECT-TYPE SYNTAX INTEGER { inService(0), outOfService(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 18 } sle2EthCfmMepInfoControlDlmState OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 19 } sle2EthCfmMepInfoControlLckLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 20 } sle2EthCfmMepInfoControlTstPattern OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 21 } sle2EthCfmMepInfoControlTstRecursive OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 22 } sle2EthCfmMepInfoControlDuration OBJECT-TYPE SYNTAX Integer32 (5..60) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 23 } sle2EthCfmMepInfoControlTstTxInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 24 } sle2EthCfmMepInfoControlTstLckInterval OBJECT-TYPE SYNTAX Integer32 (1 | 60) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 25 } sle2EthCfmMepInfoControlLckRmepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoControl 26 } sle2EthCfmMepInfoControlInterval OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates interval value. 1: 100ms 2: 10ms 3: 1s 4: 10s " ::= { sle2EthCfmMepInfoControl 27 } sle2EthCfmMepInfoControlTransMode OBJECT-TYPE SYNTAX INTEGER { oneDm(1), dvm(2), dmm(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the transmit mode." ::= { sle2EthCfmMepInfoControl 28 } sle2EthCfmMepInfoNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmMepInfo 3 } sle2EthCfmMepCreated NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepInfoIfindex, sle2EthCfmMepInfoLocalVid, sle2EthCfmMepInfoDirection, sle2EthCfmMepInfoActive, sle2EthCfmMepInfoUNI } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoNotification 1 } sle2EthCfmMepDestory NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName, sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlIfindex, sle2EthCfmMepInfoControlMepDirection, sle2EthCfmMepInfoControlLocalVid } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoNotification 2 } sle2EthCfmCcEnableChanged NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepInfoCcmFrameType, sle2EthCfmMepInfoCcmStatus, sle2EthCfmMepInfoCcmRmepId } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoNotification 3 } sle2EthCfmServiceChanged NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepInfoService, sle2EthCfmMepInfoLckLevel } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoNotification 4 } sle2EthCfmDualEndLmmChanged NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepInfoIfindex, sle2EthCfmMepInfoDlmState, sle2EthCfmMepInfoDlmRmepId } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoNotification 5 } sle2EthCfmTransmitUnicastTstFinished NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName, sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlRmepId, sle2EthCfmMepInfoControlTstPattern, sle2EthCfmMepInfoControlTstRecursive, sle2EthCfmMepInfoControlTstTxInterval, sle2EthCfmMepInfoControlTstLckInterval, sle2EthCfmMepInfoControlFrameType, sle2EthCfmMepInfoControlLckRmepId, sle2EthCfmMepInfoControlDuration } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoNotification 6 } sle2EthCfmTransmitMulticastTstFinished NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName, sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlTstPattern, sle2EthCfmMepInfoControlTstRecursive, sle2EthCfmMepInfoControlTstTxInterval, sle2EthCfmMepInfoControlTstLckInterval, sle2EthCfmMepInfoControlFrameType, sle2EthCfmMepInfoControlLckRmepId, sle2EthCfmMepInfoControlDuration } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoNotification 7 } sle2EthCfmTransmitUnicastLmFinished NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName, sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlRmepId, sle2EthCfmMepInfoControlDuration, sle2EthCfmMepInfoControlInterval } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoNotification 8 } sle2EthCfmTransmitMulticastLmFinished NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName, sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlDuration, sle2EthCfmMepInfoControlInterval } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoNotification 9 } sle2EthCfmTransmitUnicastDmFinished NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName, sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlTransMode, sle2EthCfmMepInfoControlRmepId, sle2EthCfmMepInfoControlDuration, sle2EthCfmMepInfoControlInterval } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoNotification 10 } sle2EthCfmTransmitMuliticastDmFinished NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName, sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlTransMode, sle2EthCfmMepInfoControlDuration, sle2EthCfmMepInfoControlInterval } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoNotification 11 } sle2EthCfmReceive1DmFinished NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName, sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlDuration } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoNotification 12 } sle2EthCfmTransmitTmFinished NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName, sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlRmepId } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoNotification 13 } sle2EthCfmReceiveTmFinished NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName, sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlDuration } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoNotification 14 } sle2EthCfmTransmitExmFinished NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName, sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlRmepId } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoNotification 15 } sle2EthCfmTransmitVsmFinished NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName, sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlRmepId } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoNotification 16 } sle2EthCfmTransmitMccFinished NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName, sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlFrameType, sle2EthCfmMepInfoControlRmepId } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepInfoNotification 17 } sle2EthernetCfmMepAttributs OBJECT IDENTIFIER ::= { sle2EthernetCfmMep 2 } sle2EthCfmMepAttrTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmMepAttrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmMepAttributs 1 } sle2EthCfmMepAttrEntry OBJECT-TYPE SYNTAX Sle2EthCfmMepAttrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId } ::= { sle2EthCfmMepAttrTable 1 } Sle2EthCfmMepAttrEntry ::= SEQUENCE { sle2EthCfmMepAttrActive INTEGER, sle2EthCfmMepAttrCcmLtmPriority Integer32, sle2EthCfmMepAttrLowPrDef INTEGER, sle2EthCfmMepAttrFngAlarmTime Integer32, sle2EthCfmMepAttrResetFngTime Integer32, sle2EthCfmMepAttrCcmLtmFlag Integer32, sle2EthCfmMepAttrTxLtmTargetMac OCTET STRING, sle2EthCfmMepAttrTxLtmTargetMepId Integer32, sle2EthCfmMepAttrTxLtmTargetIsMepId INTEGER, sle2EthCfmMepAttrTxLtmTtl Integer32, sle2EthCfmMepAttrTxLtmEgressId OCTET STRING, sle2EthCfmMepAttrTxLbmStatus INTEGER, sle2EthCfmMepAttrTxLbmDestMac OCTET STRING, sle2EthCfmMepAttrTxLbmDestMepId Integer32, sle2EthCfmMepAttrTxLbmDestIsMepId INTEGER, sle2EthCfmMepAttrTxLbmMessages Integer32, sle2EthCfmMepAttrTxLbmDataTlv OCTET STRING, sle2EthCfmMepAttrTxLbmVlanPriority Integer32, sle2EthCfmMepAttrTxLbmVlanDropEnable INTEGER, sle2EthCfmMepAttrTxLbmTimeOut Integer32, sle2EthCfmMepAttrLbrTimeOut Integer32 } sle2EthCfmMepAttrActive OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 1 } sle2EthCfmMepAttrCcmLtmPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 2 } sle2EthCfmMepAttrLowPrDef OBJECT-TYPE SYNTAX INTEGER { allDef(1), macRemErrXcon(2), remErrXcon(3), errXcon(4), xcon(5), noXcon(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 3 } sle2EthCfmMepAttrFngAlarmTime OBJECT-TYPE SYNTAX Integer32 (250..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 4 } sle2EthCfmMepAttrResetFngTime OBJECT-TYPE SYNTAX Integer32 (250..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 5 } sle2EthCfmMepAttrCcmLtmFlag OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 6 } sle2EthCfmMepAttrTxLtmTargetMac OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 7 } sle2EthCfmMepAttrTxLtmTargetMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 8 } sle2EthCfmMepAttrTxLtmTargetIsMepId OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 9 } sle2EthCfmMepAttrTxLtmTtl OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 10 } sle2EthCfmMepAttrTxLtmEgressId OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 11 } sle2EthCfmMepAttrTxLbmStatus OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 12 } sle2EthCfmMepAttrTxLbmDestMac OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 13 } sle2EthCfmMepAttrTxLbmDestMepId OBJECT-TYPE SYNTAX Integer32 (0..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 14 } sle2EthCfmMepAttrTxLbmDestIsMepId OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 15 } sle2EthCfmMepAttrTxLbmMessages OBJECT-TYPE SYNTAX Integer32 (1..5) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 16 } sle2EthCfmMepAttrTxLbmDataTlv OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 17 } sle2EthCfmMepAttrTxLbmVlanPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 18 } sle2EthCfmMepAttrTxLbmVlanDropEnable OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 19 } sle2EthCfmMepAttrTxLbmTimeOut OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 20 } sle2EthCfmMepAttrLbrTimeOut OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrEntry 21 } sle2EthCfmMepAttrControl OBJECT IDENTIFIER ::= { sle2EthernetCfmMepAttributs 2 } sle2EthCfmMepAttrControlRequest OBJECT-TYPE SYNTAX INTEGER { setCfmFaultProfile(1), setCfmTxLtmProfile(2), setCfmTxLbmProfile(3), clearAllCfmMepAttuributes(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 1 } sle2EthCfmMepAttrControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 2 } sle2EthCfmMepAttrControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 3 } sle2EthCfmMepAttrControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 4 } sle2EthCfmMepAttrControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 5 } sle2EthCfmMepAttrControlBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 6 } sle2EthCfmMepAttrControlMdName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 7 } sle2EthCfmMepAttrControlMaVid OBJECT-TYPE SYNTAX Integer32 (0..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 8 } sle2EthCfmMepAttrControlMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 9 } sle2EthCfmMepAttrControlActive OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 10 } sle2EthCfmMepAttrControlCcmLtmPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 11 } sle2EthCfmMepAttrContrlLowPrDef OBJECT-TYPE SYNTAX INTEGER { allDef(1), macRemErrXcon(2), remErrXcon(3), errXcon(4), xcon(5), noXcon(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 12 } sle2EthCfmMepAttrContrlFngAlarmTime OBJECT-TYPE SYNTAX Integer32 (250..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 13 } sle2EthCfmMepAttrControlResetFngTime OBJECT-TYPE SYNTAX Integer32 (250..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 14 } sle2EthCfmMepAttrControlCcmLtmFlag OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 15 } sle2EthCfmMepAttrControlTxLtmTargetMac OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 16 } sle2EthCfmMepAttrControlTxLtmTargetMepId OBJECT-TYPE SYNTAX Integer32 (0..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 17 } sle2EthCfmMepAttrControlTxLtmTargetIsMepId OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 18 } sle2EthCfmMepAttrControlTxLtmTtl OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 19 } sle2EthCfmMepAttrControlTxLtmEgressId OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 20 } sle2EthCfmMepAttrControlTxLbmStatus OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 21 } sle2EthCfmMepAttrControlTxLbmDestMacAddress OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 22 } sle2EthCfmMepAttrControlTxLbmDestMepId OBJECT-TYPE SYNTAX Integer32 (0..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 23 } sle2EthCfmMepAttrControlTxLbmDestIsMepId OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 24 } sle2EthCfmMepAttrControlTxLbmMessages OBJECT-TYPE SYNTAX Integer32 (1..5) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 25 } sle2EthCfmMepAttrControlTxLbmDataTlv OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 26 } sle2EthCfmMepAttrControlTxLbmVlanPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 27 } sle2EthCfmMepAttrControlTxLbmVlanDropEnable OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 28 } sle2EthCfmMepAttrControlTxLbmTimeOut OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 29 } sle2EthCfmMepAttrControlLbrTimeOut OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrControl 30 } sle2EthCfmMepAttrNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmMepAttributs 3 } sle2EthCfmMepFaultProfileChanged NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepAttrControlRequest, sle2EthCfmMepAttrControlReqResult, sle2EthCfmMepAttrControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepAttrCcmLtmPriority, sle2EthCfmMepAttrLowPrDef, sle2EthCfmMepAttrFngAlarmTime, sle2EthCfmMepAttrResetFngTime, sle2EthCfmMepAttrActive } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrNotification 1 } sle2EthCfmMepTxLtmProfileChanged NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepAttrControlRequest, sle2EthCfmMepAttrControlReqResult, sle2EthCfmMepAttrControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepAttrCcmLtmFlag, sle2EthCfmMepAttrTxLtmTargetMac, sle2EthCfmMepAttrTxLtmTargetMepId, sle2EthCfmMepAttrTxLtmTargetIsMepId, sle2EthCfmMepAttrTxLtmTtl, sle2EthCfmMepAttrTxLtmEgressId } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrNotification 2 } sle2EthCfmMepTxLbmProfileChanged NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepAttrControlRequest, sle2EthCfmMepAttrControlReqResult, sle2EthCfmMepAttrControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepAttrTxLbmStatus, sle2EthCfmMepAttrTxLbmDestMac, sle2EthCfmMepAttrTxLbmDestMepId, sle2EthCfmMepAttrTxLbmDestIsMepId, sle2EthCfmMepAttrTxLbmMessages, sle2EthCfmMepAttrTxLbmDataTlv, sle2EthCfmMepAttrTxLbmVlanPriority, sle2EthCfmMepAttrTxLbmVlanDropEnable, sle2EthCfmMepAttrTxLbmTimeOut, sle2EthCfmMepAttrLbrTimeOut } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrNotification 3 } sle2EthCfmMepAuttributesAllCleared NOTIFICATION-TYPE OBJECTS { sle2EthCfmMepAttrControlRequest, sle2EthCfmMepAttrControlReqResult, sle2EthCfmMepAttrControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMepAttrNotification 4 } sle2EthernetCfmXcheck OBJECT IDENTIFIER ::= { sle2EthernetCfm 8 } sle2EthCfmXcheckTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmXcheckEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmXcheck 1 } sle2EthCfmXcheckEntry OBJECT-TYPE SYNTAX Sle2EthCfmXcheckEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmXcheckRmepId } ::= { sle2EthCfmXcheckTable 1 } Sle2EthCfmXcheckEntry ::= SEQUENCE { sle2EthCfmXcheckRmepId Integer32, sle2EthCfmXcheckRmepMac OCTET STRING } sle2EthCfmXcheckRmepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmXcheckEntry 1 } sle2EthCfmXcheckRmepMac OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmXcheckEntry 2 } sle2EthCfmXcheckControl OBJECT IDENTIFIER ::= { sle2EthernetCfmXcheck 2 } sle2EthCfmXcheckControlRequest OBJECT-TYPE SYNTAX INTEGER { createCfmXcheckMep(1), destoryCfmXcheckMep(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmXcheckControl 1 } sle2EthCfmXcheckControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmXcheckControl 2 } sle2EthCfmXcheckControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmXcheckControl 3 } sle2EthCfmXcheckControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmXcheckControl 4 } sle2EthCfmXcheckControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmXcheckControl 5 } sle2EthCfmXcheckControlBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmXcheckControl 6 } sle2EthCfmXcheckControlMdName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmXcheckControl 7 } sle2EthCfmXcheckControlMaVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmXcheckControl 8 } sle2EthCfmXcheckControlRmepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmXcheckControl 9 } sle2EthCfmXcheckControlRmepMac OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmXcheckControl 10 } sle2EthCfmXcheckNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmXcheck 3 } sle2EthCfmXcheckMepCreated NOTIFICATION-TYPE OBJECTS { sle2EthCfmXcheckControlRequest, sle2EthCfmXcheckControlReqResult, sle2EthCfmXcheckControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmXcheckRmepId, sle2EthCfmXcheckRmepMac } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmXcheckNotification 1 } sle2EthCfmXcheckMepDestoryed NOTIFICATION-TYPE OBJECTS { sle2EthCfmXcheckControlRequest, sle2EthCfmXcheckControlReqResult, sle2EthCfmXcheckControlTimeStamp, sle2EthCfmXcheckControlBridgeId, sle2EthCfmXcheckControlMdName, sle2EthCfmXcheckControlMaVid, sle2EthCfmXcheckControlRmepId, sle2EthCfmXcheckControlRmepMac } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmXcheckNotification 2 } sle2EthernetCfmLoopback OBJECT IDENTIFIER ::= { sle2EthernetCfm 9 } sle2EthCfmLoopbackTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmLoopbackEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmLoopback 1 } sle2EthCfmLoopbackEntry OBJECT-TYPE SYNTAX Sle2EthCfmLoopbackEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId } ::= { sle2EthCfmLoopbackTable 1 } Sle2EthCfmLoopbackEntry ::= SEQUENCE { sle2EthCfmLbFrameType INTEGER, sle2EthCfmLbReceivedCount Integer32, sle2EthCfmLbTxMessages Integer32, sle2EthCfmLbResponseCount Integer32, sle2EthCfmLbRemoteMacAddress OCTET STRING } sle2EthCfmLbFrameType OBJECT-TYPE SYNTAX INTEGER { unicast(1), multicast(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackEntry 1 } sle2EthCfmLbReceivedCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackEntry 2 } sle2EthCfmLbTxMessages OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackEntry 3 } sle2EthCfmLbResponseCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackEntry 4 } sle2EthCfmLbRemoteMacAddress OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackEntry 5 } sle2EthCfmLoopbackControl OBJECT IDENTIFIER ::= { sle2EthernetCfmLoopback 2 } sle2EthCfmLbControlRequest OBJECT-TYPE SYNTAX INTEGER { transmitMulticastLb(1), transmitUnicastLb(2), transmitMacLb(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackControl 1 } sle2EthCfmLbControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackControl 2 } sle2EthCfmLbControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackControl 3 } sle2EthCfmLbControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackControl 4 } sle2EthCfmLbControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackControl 5 } sle2EthCfmLbControlBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackControl 6 } sle2EthCfmLbControlMdName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackControl 7 } sle2EthCfmLbControlMaVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackControl 8 } sle2EthCfmLbControlMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackControl 9 } sle2EthCfmLbControlMdLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackControl 10 } sle2EthCfmLbControlRmepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackControl 11 } sle2EthCfmLbControlRmepMac OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackControl 12 } sle2EthCfmLbControlTlvType OBJECT-TYPE SYNTAX INTEGER { tlvData(1), tlvTest(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackControl 13 } sle2EthCfmLbControlTlvData OBJECT-TYPE SYNTAX Integer32 (1..9000) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackControl 14 } sle2EthCfmLbControlTlvTest OBJECT-TYPE SYNTAX INTEGER { pattern1(1), pattern2(2), pattern3(3), pattern4(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackControl 15 } sle2EthCfmLbControlRecursive OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackControl 16 } sle2EthCfmLoopbackNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmLoopback 3 } sle2EthCfmLbTransmitMulticastFinished NOTIFICATION-TYPE OBJECTS { sle2EthCfmLbControlRequest, sle2EthCfmLbControlReqResult, sle2EthCfmLbControlTimeStamp, sle2EthCfmLbControlBridgeId, sle2EthCfmLbControlMdName, sle2EthCfmLbControlMaVid, sle2EthCfmLbControlMepId, sle2EthCfmLbControlMdLevel, sle2EthCfmLbControlTlvType, sle2EthCfmLbControlTlvData, sle2EthCfmLbControlTlvTest, sle2EthCfmLbControlRecursive } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackNotification 1 } sle2EthCfmLbTransmitUnicastFinished NOTIFICATION-TYPE OBJECTS { sle2EthCfmLbControlRequest, sle2EthCfmLbControlReqResult, sle2EthCfmLbControlTimeStamp, sle2EthCfmLbControlBridgeId, sle2EthCfmLbControlMdName, sle2EthCfmLbControlMaVid, sle2EthCfmLbControlMepId, sle2EthCfmLbControlMdLevel, sle2EthCfmLbControlRmepId, sle2EthCfmLbControlTlvType, sle2EthCfmLbControlTlvData, sle2EthCfmLbControlTlvTest } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackNotification 2 } sle2EthCfmLbTransmitMacFinished NOTIFICATION-TYPE OBJECTS { sle2EthCfmLbControlRequest, sle2EthCfmLbControlReqResult, sle2EthCfmLbControlTimeStamp, sle2EthCfmLbControlBridgeId, sle2EthCfmLbControlMdName, sle2EthCfmLbControlMaVid, sle2EthCfmLbControlMepId, sle2EthCfmLbControlMdLevel, sle2EthCfmLbControlRmepMac, sle2EthCfmLbControlTlvType, sle2EthCfmLbControlTlvData, sle2EthCfmLbControlTlvTest } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackNotification 3 } sle2EthCfmLbrFinished NOTIFICATION-TYPE OBJECTS { sle2EthCfmLbControlRequest, sle2EthCfmLbControlReqResult, sle2EthCfmLbControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmLbFrameType, sle2EthCfmLbReceivedCount, sle2EthCfmLbRemoteMacAddress, sle2EthCfmLbTxMessages, sle2EthCfmLbResponseCount } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLoopbackNotification 4 } sle2EthernetCfmLinkTrace OBJECT IDENTIFIER ::= { sle2EthernetCfm 10 } sle2EthCfmLinkTraceTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmLinkTraceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmLinkTrace 1 } sle2EthCfmLinkTraceEntry OBJECT-TYPE SYNTAX Sle2EthCfmLinkTraceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId } ::= { sle2EthCfmLinkTraceTable 1 } Sle2EthCfmLinkTraceEntry ::= SEQUENCE { sle2EthCfmLtrMepMac OCTET STRING, sle2EthCfmLtrHops Integer32, sle2EthCfmLtrRelay INTEGER, sle2EthCfmLtrIngressEgress INTEGER, sle2EthCfmLtrIngress INTEGER, sle2EthCfmLtrEgress INTEGER } sle2EthCfmLtrMepMac OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLinkTraceEntry 1 } sle2EthCfmLtrHops OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLinkTraceEntry 2 } sle2EthCfmLtrRelay OBJECT-TYPE SYNTAX INTEGER { unknown(0), rlyHit(1), rlyFDB(2), rlyMPDB(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLinkTraceEntry 3 } sle2EthCfmLtrIngressEgress OBJECT-TYPE SYNTAX INTEGER { ingress(1), egress(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLinkTraceEntry 4 } sle2EthCfmLtrIngress OBJECT-TYPE SYNTAX INTEGER { ingNoTlv(0), ingOK(1), ingDown(2), ingBlocked(3), ingVid(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLinkTraceEntry 5 } sle2EthCfmLtrEgress OBJECT-TYPE SYNTAX INTEGER { egrNoTlv(0), egrOK(1), egrDown(2), egrBlocked(3), egrVid(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLinkTraceEntry 6 } sle2EthCfmLinkTraceControl OBJECT IDENTIFIER ::= { sle2EthernetCfmLinkTrace 2 } sle2EthCfmLtControlRequest OBJECT-TYPE SYNTAX INTEGER { transmitLtDomain(1), transmitLtLevel(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLinkTraceControl 1 } sle2EthCfmLtControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLinkTraceControl 2 } sle2EthCfmLtControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLinkTraceControl 3 } sle2EthCfmLtControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLinkTraceControl 4 } sle2EthCfmLtControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLinkTraceControl 5 } sle2EthCfmLtControlBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLinkTraceControl 6 } sle2EthCfmLtControlMdName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLinkTraceControl 7 } sle2EthCfmLtControlMaVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLinkTraceControl 8 } sle2EthCfmLtControlLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLinkTraceControl 9 } sle2EthCfmLtControlRmepMac OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLinkTraceControl 10 } sle2EthCfmLtControlMepId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "indicates mepid of local." ::= { sle2EthCfmLinkTraceControl 11 } sle2EthCfmLinkTraceNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmLinkTrace 3 } sle2EthCfmLtTransmitDomainFinished NOTIFICATION-TYPE OBJECTS { sle2EthCfmLtControlRequest, sle2EthCfmLtControlReqResult, sle2EthCfmLtControlTimeStamp, sle2EthCfmLtControlBridgeId, sle2EthCfmLtControlMdName, sle2EthCfmLtControlMaVid, sle2EthCfmLtControlRmepMac } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLinkTraceNotification 1 } sle2EthCfmLtTransmitLevelFinished NOTIFICATION-TYPE OBJECTS { sle2EthCfmLtControlRequest, sle2EthCfmLtControlReqResult, sle2EthCfmLtControlTimeStamp, sle2EthCfmLtControlBridgeId, sle2EthCfmLtControlMaVid, sle2EthCfmLtControlLevel, sle2EthCfmLtControlRmepMac } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLinkTraceNotification 2 } sle2EthCfmLtrFinished NOTIFICATION-TYPE OBJECTS { sle2EthCfmLtControlRequest, sle2EthCfmLtControlReqResult, sle2EthCfmLtControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmLtrMepMac, sle2EthCfmLtrHops, sle2EthCfmLtrRelay, sle2EthCfmLtrIngressEgress, sle2EthCfmLtrIngress, sle2EthCfmLtrEgress } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLinkTraceNotification 3 } sle2EthernetCfmAis OBJECT IDENTIFIER ::= { sle2EthernetCfm 11 } sle2EthernetCfmAisInfo OBJECT IDENTIFIER ::= { sle2EthernetCfmAis 1 } sle2EthCfmAisInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmAisInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmAisInfo 1 } sle2EthCfmAisInfoEntry OBJECT-TYPE SYNTAX Sle2EthCfmAisInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmAisInfoDefectConditions, sle2EthCfmAisInfoLevel, sle2EthCfmAisInfoRmepMac } ::= { sle2EthCfmAisInfoTable 1 } Sle2EthCfmAisInfoEntry ::= SEQUENCE { sle2EthCfmAisInfoStatus INTEGER, sle2EthCfmAisInfoDefectConditions INTEGER, sle2EthCfmAisInfoLevel Integer32, sle2EthCfmAisInfoFrameType INTEGER, sle2EthCfmAisInfoRmepMac OCTET STRING, sle2EthCfmAisInfoInterval Integer32, sle2EthCfmAisInfoReceivedDefectConditions INTEGER, sle2EthCfmAisInfoLastReceivedDefectCondition INTEGER } sle2EthCfmAisInfoStatus OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoEntry 1 } sle2EthCfmAisInfoDefectConditions OBJECT-TYPE SYNTAX INTEGER { all(1), loc(2), mismerge(3), unexpectedMep(4), unexpectedMegLevel(5), unexpectedPeriod(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoEntry 2 } sle2EthCfmAisInfoLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoEntry 3 } sle2EthCfmAisInfoFrameType OBJECT-TYPE SYNTAX INTEGER { unicast(1), multicast(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoEntry 4 } sle2EthCfmAisInfoRmepMac OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoEntry 5 } sle2EthCfmAisInfoInterval OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoEntry 6 } sle2EthCfmAisInfoReceivedDefectConditions OBJECT-TYPE SYNTAX INTEGER { all(1), loc(2), mismerge(3), unexpectedMep(4), unexpectedMegLevel(5), unexpectedPeriod(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoEntry 7 } sle2EthCfmAisInfoLastReceivedDefectCondition OBJECT-TYPE SYNTAX INTEGER { all(1), loc(2), mismerge(3), unexpectedMep(4), unexpectedMegLevel(5), unexpectedPeriod(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoEntry 8 } sle2EthCfmAisInfoControl OBJECT IDENTIFIER ::= { sle2EthernetCfmAisInfo 2 } sle2EthCfmAisInfoControlRequest OBJECT-TYPE SYNTAX INTEGER { setCfmAisInfoStatus(1), setCfmAisInfoInterval(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoControl 1 } sle2EthCfmAisInfoControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoControl 2 } sle2EthCfmAisInfoControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoControl 3 } sle2EthCfmAisInfoControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoControl 4 } sle2EthCfmAisInfoControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoControl 5 } sle2EthCfmAisInfoControlBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoControl 6 } sle2EthCfmAisInfoControlMdName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoControl 7 } sle2EthCfmAisInfoControlMaVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoControl 8 } sle2EthCfmAisInfoControlMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoControl 9 } sle2EthCfmAisInfoControlEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoControl 10 } sle2EthCfmAisInfoControlDefectConditions OBJECT-TYPE SYNTAX INTEGER { all(1), loc(2), mismerge(3), unexpectedMep(4), unexpectedMegLevel(5), unexpectedPeriod(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoControl 11 } sle2EthCfmAisInfoControlLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoControl 12 } sle2EthCfmAisInfoControlFrameType OBJECT-TYPE SYNTAX INTEGER { unicast(1), multicast(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoControl 13 } sle2EthCfmAisInfoControlRmepMac OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoControl 14 } sle2EthCfmAisInfoControlInterval OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoControl 15 } sle2EthCfmAisInfoNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmAisInfo 3 } sle2EthCfmAisInfoStatusChanged NOTIFICATION-TYPE OBJECTS { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmAisInfoStatus, sle2EthCfmAisInfoDefectConditions, sle2EthCfmAisInfoLevel, sle2EthCfmAisInfoFrameType, sle2EthCfmAisInfoRmepMac } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoNotification 1 } sle2EthCfmAisInfoIntervalChanged NOTIFICATION-TYPE OBJECTS { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmAisInfoInterval } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmAisInfoNotification 2 } sle2EthernetCfmSrvAis OBJECT IDENTIFIER ::= { sle2EthernetCfmAis 2 } sle2EthCfmSrvAisTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmSrvAisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmSrvAis 1 } sle2EthCfmSrvAisEntry OBJECT-TYPE SYNTAX Sle2EthCfmSrvAisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId, sle2EthCfmSrvAisIfIndex } ::= { sle2EthCfmSrvAisTable 1 } Sle2EthCfmSrvAisEntry ::= SEQUENCE { sle2EthCfmSrvAisIfIndex Integer32, sle2EthCfmSrvAisEnable INTEGER, sle2EthCfmSrvAislevel Integer32, sle2EthCfmSrvAisInterval Integer32 } sle2EthCfmSrvAisIfIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmSrvAisEntry 1 } sle2EthCfmSrvAisEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmSrvAisEntry 2 } sle2EthCfmSrvAislevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmSrvAisEntry 3 } sle2EthCfmSrvAisInterval OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmSrvAisEntry 4 } sle2EthCfmSrvAisControl OBJECT IDENTIFIER ::= { sle2EthernetCfmSrvAis 2 } sle2EthCfmSrvAisControlRequest OBJECT-TYPE SYNTAX INTEGER { setCfmSrvAisEnable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmSrvAisControl 1 } sle2EthCfmSrvAisControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmSrvAisControl 2 } sle2EthCfmSrvAisControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmSrvAisControl 3 } sle2EthCfmSrvAisControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmSrvAisControl 4 } sle2EthCfmSrvAisControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmSrvAisControl 5 } sle2EthCfmSrvAisControlBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32 | 100) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmSrvAisControl 6 } sle2EthCfmSrvAisControlIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmSrvAisControl 7 } sle2EthCfmSrvAisControlEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmSrvAisControl 8 } sle2EthCfmSrvAisControlLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmSrvAisControl 9 } sle2EthCfmSrvAisControlInterval OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmSrvAisControl 10 } sle2EthCfmSrvAisNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmSrvAis 3 } sle2EthCfmSrvAisChanged NOTIFICATION-TYPE OBJECTS { sle2EthCfmBridgeId, sle2EthCfmSrvAisIfIndex, sle2EthCfmSrvAisEnable, sle2EthCfmSrvAislevel, sle2EthCfmSrvAisInterval } STATUS current DESCRIPTION "Description." ::= { sle2EthCfmSrvAisNotification 1 } sle2EthernetCfmLmStatus OBJECT IDENTIFIER ::= { sle2EthernetCfm 12 } sle2EthCfmLmmStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmLmmStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmLmStatus 1 } sle2EthCfmLmmStatusEntry OBJECT-TYPE SYNTAX Sle2EthCfmLmmStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId } ::= { sle2EthCfmLmmStatusTable 1 } Sle2EthCfmLmmStatusEntry ::= SEQUENCE { sle2EthCfmLmmStatusRmepId Integer32, sle2EthCfmLmmStatusStartTime TimeTicks, sle2EthCfmLmmStatusCurrentTime TimeTicks, sle2EthCfmLmmStatusEndTime TimeTicks, sle2EthCfmLmmStatusNeerLoss Integer32, sle2EthCfmLmmStatusFarLoss Integer32, sle2EthCfmLmmStatusCurNeerLoss Integer32, sle2EthCfmLmmStatusCurFarLoss Integer32 } sle2EthCfmLmmStatusRmepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLmmStatusEntry 1 } sle2EthCfmLmmStatusStartTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLmmStatusEntry 2 } sle2EthCfmLmmStatusCurrentTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLmmStatusEntry 3 } sle2EthCfmLmmStatusEndTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLmmStatusEntry 4 } sle2EthCfmLmmStatusNeerLoss OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLmmStatusEntry 5 } sle2EthCfmLmmStatusFarLoss OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLmmStatusEntry 6 } sle2EthCfmLmmStatusCurNeerLoss OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLmmStatusEntry 7 } sle2EthCfmLmmStatusCurFarLoss OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmLmmStatusEntry 8 } sle2EthernetCfmRmep OBJECT IDENTIFIER ::= { sle2EthernetCfm 13 } sle2EthCfmRmepTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmRmepEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmRmep 1 } sle2EthCfmRmepEntry OBJECT-TYPE SYNTAX Sle2EthCfmRmepEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmRmepId } ::= { sle2EthCfmRmepTable 1 } Sle2EthCfmRmepEntry ::= SEQUENCE { sle2EthCfmRmepId Integer32, sle2EthCfmRempMepId Integer32, sle2EthCfmRmepLevel Integer32, sle2EthCfmRmepMaVid Integer32, sle2EthCfmRmepActiveState INTEGER, sle2EthCfmRmepRemoteMac OCTET STRING, sle2EthCfmRmepRdi INTEGER, sle2EthCfmRmepFlags INTEGER } sle2EthCfmRmepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates mepid of remote." ::= { sle2EthCfmRmepEntry 1 } sle2EthCfmRempMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2EthCfmRmepEntry 2 } sle2EthCfmRmepLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the maintenance domain level." ::= { sle2EthCfmRmepEntry 3 } sle2EthCfmRmepMaVid OBJECT-TYPE SYNTAX Integer32 (0..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "The VLAN Identifier. 0: default Ma vid " ::= { sle2EthCfmRmepEntry 4 } sle2EthCfmRmepActiveState OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates active status." ::= { sle2EthCfmRmepEntry 5 } sle2EthCfmRmepRemoteMac OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the remote mac address." ::= { sle2EthCfmRmepEntry 6 } sle2EthCfmRmepRdi OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the RDI flags." ::= { sle2EthCfmRmepEntry 7 } sle2EthCfmRmepFlags OBJECT-TYPE SYNTAX INTEGER { configured(1), configuredLearnt(2), learnt(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates configure status" ::= { sle2EthCfmRmepEntry 8 } sle2EthCfmRmepControl OBJECT IDENTIFIER ::= { sle2EthernetCfmRmep 2 } sle2EthCfmRmepControlRequest OBJECT-TYPE SYNTAX INTEGER { clearRmepDomain(1), clearRmepLevel(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The request of a user command" ::= { sle2EthCfmRmepControl 1 } sle2EthCfmRmepControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "The status of user command" ::= { sle2EthCfmRmepControl 2 } sle2EthCfmRmepControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum time for the manager for a long running user command" ::= { sle2EthCfmRmepControl 3 } sle2EthCfmRmepControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "The time stamp of the last command(end of command)" ::= { sle2EthCfmRmepControl 4 } sle2EthCfmRmepControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Result of the last command." ::= { sle2EthCfmRmepControl 5 } sle2EthCfmRmepControlBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates bridgegroup id 1: default bridge id " ::= { sle2EthCfmRmepControl 6 } sle2EthCfmRmepControlMdName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "The maintenance domain name." ::= { sle2EthCfmRmepControl 7 } sle2EthCfmRmepControlMdLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the maintenance domain level." ::= { sle2EthCfmRmepControl 8 } sle2EthCfmRmepNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmRmep 3 } sle2EthCfmRmepDomainCleared NOTIFICATION-TYPE OBJECTS { sle2EthCfmRmepControlRequest, sle2EthCfmRmepControlReqResult, sle2EthCfmRmepControlTimeStamp, sle2EthCfmRmepControlBridgeId, sle2EthCfmRmepControlMdName } STATUS current DESCRIPTION "clearRmepDomain" ::= { sle2EthCfmRmepNotification 1 } sle2EthCfmRmepLevelCleared NOTIFICATION-TYPE OBJECTS { sle2EthCfmRmepControlRequest, sle2EthCfmRmepControlReqResult, sle2EthCfmRmepControlTimeStamp, sle2EthCfmRmepControlBridgeId, sle2EthCfmRmepControlMdLevel } STATUS current DESCRIPTION "clearRmepLevel" ::= { sle2EthCfmRmepNotification 2 } sle2EthernetCfmMip OBJECT IDENTIFIER ::= { sle2EthernetCfm 14 } sle2EthCfmMipTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmMipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmMip 1 } sle2EthCfmMipEntry OBJECT-TYPE SYNTAX Sle2EthCfmMipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId, sle2EthCfmMipVid, sle2EthCfmMipMdLevel, sle2EthCfmMipIfindex } ::= { sle2EthCfmMipTable 1 } Sle2EthCfmMipEntry ::= SEQUENCE { sle2EthCfmMipVid Integer32, sle2EthCfmMipMdLevel Integer32, sle2EthCfmMipIfindex Integer32, sle2EthCfmMipLocalMac OCTET STRING } sle2EthCfmMipVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2EthCfmMipEntry 1 } sle2EthCfmMipMdLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the maintenance domain level." ::= { sle2EthCfmMipEntry 2 } sle2EthCfmMipIfindex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Indcates the port interface index." ::= { sle2EthCfmMipEntry 3 } sle2EthCfmMipLocalMac OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The mac address of local mep." ::= { sle2EthCfmMipEntry 4 } sle2EthernetCfmStatistics OBJECT IDENTIFIER ::= { sle2EthernetCfm 15 } sle2EthCfmStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmStatistics 1 } sle2EthCfmStatisticsEntry OBJECT-TYPE SYNTAX Sle2EthCfmStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId } ::= { sle2EthCfmStatisticsTable 1 } Sle2EthCfmStatisticsEntry ::= SEQUENCE { sle2EthCfmStatCcmSent Gauge32, sle2EthCfmStatCcmRevOutOfSeq Gauge32, sle2EthCfmStatLbrSent Gauge32, sle2EthCfmStatLbrRevValid Gauge32, sle2EthCfmStatLbrRevBadMsdu Gauge32, sle2EthCfmStatLbrRevOutOfSeq Gauge32, sle2EthCfmStatLtrRevUnexpected Counter32 } sle2EthCfmStatCcmSent OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ccm packet number." ::= { sle2EthCfmStatisticsEntry 1 } sle2EthCfmStatCcmRevOutOfSeq OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the received out of sequence number." ::= { sle2EthCfmStatisticsEntry 2 } sle2EthCfmStatLbrSent OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the lbr packet number." ::= { sle2EthCfmStatisticsEntry 3 } sle2EthCfmStatLbrRevValid OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the valid lbr packet number." ::= { sle2EthCfmStatisticsEntry 4 } sle2EthCfmStatLbrRevBadMsdu OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the bad lbr packet number." ::= { sle2EthCfmStatisticsEntry 5 } sle2EthCfmStatLbrRevOutOfSeq OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the received out of sequence number." ::= { sle2EthCfmStatisticsEntry 6 } sle2EthCfmStatLtrRevUnexpected OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the unexected received lbr packet number." ::= { sle2EthCfmStatisticsEntry 7 } sle2EthernetCfmActiveLevel OBJECT IDENTIFIER ::= { sle2EthernetCfm 16 } sle2EthCfmActiveLevelTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmActiveLevelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmActiveLevel 1 } sle2EthCfmActiveLevelEntry OBJECT-TYPE SYNTAX Sle2EthCfmActiveLevelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId, sle2EthCfmMaVid, sle2EthCfmAcitveLevelIfIndex } ::= { sle2EthCfmActiveLevelTable 1 } Sle2EthCfmActiveLevelEntry ::= SEQUENCE { sle2EthCfmAcitveLevelIfIndex Integer32, sle2EthCfmActiveLevelStatus BITS } sle2EthCfmAcitveLevelIfIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The interface index." ::= { sle2EthCfmActiveLevelEntry 1 } sle2EthCfmActiveLevelStatus OBJECT-TYPE SYNTAX BITS { level7(0), level6(1), level5(2), level4(3), level3(4), level2(5), level1(6), level0(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates status of active level " ::= { sle2EthCfmActiveLevelEntry 2 } sle2EthernetCfmError OBJECT IDENTIFIER ::= { sle2EthernetCfm 17 } sle2EthCfmErrorTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmErrorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmError 1 } sle2EthCfmErrorEntry OBJECT-TYPE SYNTAX Sle2EthCfmErrorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmErrorIndex } ::= { sle2EthCfmErrorTable 1 } Sle2EthCfmErrorEntry ::= SEQUENCE { sle2EthCfmErrorIndex Integer32, sle2EthCfmErrorMdLevel Integer32, sle2EthCfmErrorMaVid Integer32, sle2EthCfmErrorMepId Integer32, sle2EthCfmErrorRmepMac OCTET STRING, sle2EthCfmErrorReason INTEGER, sle2EthCfmErrorServiceId OCTET STRING } sle2EthCfmErrorIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the error index." ::= { sle2EthCfmErrorEntry 1 } sle2EthCfmErrorMdLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates level of MD." ::= { sle2EthCfmErrorEntry 2 } sle2EthCfmErrorMaVid OBJECT-TYPE SYNTAX Integer32 (0..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "The VLAN Identifier. 0: default Ma vid " ::= { sle2EthCfmErrorEntry 3 } sle2EthCfmErrorMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "The MA end point ID." ::= { sle2EthCfmErrorEntry 4 } sle2EthCfmErrorRmepMac OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates mac address of remote mep " ::= { sle2EthCfmErrorEntry 5 } sle2EthCfmErrorReason OBJECT-TYPE SYNTAX INTEGER { rmepDown(0), confError(1), fowardLoop(2), crossConnect(3), missingRmep(4), unknownMep(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates error reason." ::= { sle2EthCfmErrorEntry 6 } sle2EthCfmErrorServiceId OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The maintenance association name." ::= { sle2EthCfmErrorEntry 7 } sle2EthCfmErrorControl OBJECT IDENTIFIER ::= { sle2EthernetCfmError 2 } sle2EthCfmErrorControlRequest OBJECT-TYPE SYNTAX INTEGER { clearCfmErrorDomain(1), clearCfmErrorLevel(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The request of a user command" ::= { sle2EthCfmErrorControl 1 } sle2EthCfmErrorControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "The status of user command" ::= { sle2EthCfmErrorControl 2 } sle2EthCfmErrorControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum time for the manager for a long running user command" ::= { sle2EthCfmErrorControl 3 } sle2EthCfmErrorControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "The time stamp of the last command(end of command)" ::= { sle2EthCfmErrorControl 4 } sle2EthCfmErrorControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Result of the last command." ::= { sle2EthCfmErrorControl 5 } sle2EthCfmErrorControlBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates bridgegroup id 1: default bridge id " ::= { sle2EthCfmErrorControl 6 } sle2EthCfmErrorControlMdName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "The maintenance domain name." ::= { sle2EthCfmErrorControl 7 } sle2EthCfmErrorControlMdLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates level of MD." ::= { sle2EthCfmErrorControl 8 } sle2EthCfmErrorNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmError 3 } sle2EthCfmErrorDomainCleared NOTIFICATION-TYPE OBJECTS { sle2EthCfmErrorControlRequest, sle2EthCfmErrorControlReqResult, sle2EthCfmErrorControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName } STATUS current DESCRIPTION "clearCfmErrorDomain" ::= { sle2EthCfmErrorNotification 1 } sle2EthCfmErrorLevelCleared NOTIFICATION-TYPE OBJECTS { sle2EthCfmErrorControlRequest, sle2EthCfmErrorControlReqResult, sle2EthCfmErrorControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmErrorMdLevel } STATUS current DESCRIPTION "clearCfmErrorLevel" ::= { sle2EthCfmErrorNotification 2 } sle2EthernetCfmLtCache OBJECT IDENTIFIER ::= { sle2EthernetCfm 18 } sle2EthCfmLtCacheTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2EthCfmLtCacheEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2EthernetCfmLtCache 1 } sle2EthCfmLtCacheEntry OBJECT-TYPE SYNTAX Sle2EthCfmLtCacheEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2EthCfmBridgeId, sle2EthCfmLtCacheIndex } ::= { sle2EthCfmLtCacheTable 1 } Sle2EthCfmLtCacheEntry ::= SEQUENCE { sle2EthCfmLtCacheIndex Integer32, sle2EthCfmLtCacheSrcMac OCTET STRING, sle2EthCfmLtCacheHops Integer32, sle2EthCfmLtCacheRelay INTEGER } sle2EthCfmLtCacheIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the linktrace cache index." ::= { sle2EthCfmLtCacheEntry 1 } sle2EthCfmLtCacheSrcMac OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates MAC address. (SIZE (6))" ::= { sle2EthCfmLtCacheEntry 2 } sle2EthCfmLtCacheHops OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates TTL field value for a returned LTR." ::= { sle2EthCfmLtCacheEntry 3 } sle2EthCfmLtCacheRelay OBJECT-TYPE SYNTAX INTEGER { unknown(0), rlyHit(1), rlyFDB(2), rlyMPDB(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the value returned in the Relay Action field" ::= { sle2EthCfmLtCacheEntry 4 } sle2Erps OBJECT IDENTIFIER ::= { sleFaultMgmt 18 } sle2ErpsPhyRing OBJECT IDENTIFIER ::= { sle2Erps 1 } sle2ErpsPhyRingTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2ErpsPhyRingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2ErpsPhyRing 1 } sle2ErpsPhyRingEntry OBJECT-TYPE SYNTAX Sle2ErpsPhyRingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName } ::= { sle2ErpsPhyRingTable 1 } Sle2ErpsPhyRingEntry ::= SEQUENCE { sle2ErpsPhyRingBridgeId Integer32, sle2ErpsPhyRingName OCTET STRING, sle2ErpsPhyRingEastPort Integer32, sle2ErpsPhyRingEastMepId Integer32, sle2ErpsPhyRingEastRmepId Integer32, sle2ErpsPhyRingWestPort Integer32, sle2ErpsPhyRingWestMepId Integer32, sle2ErpsPhyRingWestRmepId Integer32 } sle2ErpsPhyRingBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32 | 100) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates primary bridgegroup id 1: default bridge id 100: backbone" ::= { sle2ErpsPhyRingEntry 1 } sle2ErpsPhyRingName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Physical ring name (maximum 37 characters)." ::= { sle2ErpsPhyRingEntry 2 } sle2ErpsPhyRingEastPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring Node’s east port(ifindex)" ::= { sle2ErpsPhyRingEntry 3 } sle2ErpsPhyRingEastMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2ErpsPhyRingEntry 4 } sle2ErpsPhyRingEastRmepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2ErpsPhyRingEntry 5 } sle2ErpsPhyRingWestPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring Node’s west port(ifindex)" ::= { sle2ErpsPhyRingEntry 6 } sle2ErpsPhyRingWestMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2ErpsPhyRingEntry 7 } sle2ErpsPhyRingWestRmepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2ErpsPhyRingEntry 8 } sle2ErpsPhyRingControl OBJECT IDENTIFIER ::= { sle2ErpsPhyRing 2 } sle2ErpsPhyRingControlRequest OBJECT-TYPE SYNTAX INTEGER { createPhyRing(1), destoryPhyRing(2), addEastPort(3), delEastPort(4), addWestPort(5), delWestPort(6), addEastPortMepId(7), delEastPortMepId(8), addWestPortMepId(9), delWestPortMepId(10) } MAX-ACCESS read-write STATUS current DESCRIPTION "The request of a user command" ::= { sle2ErpsPhyRingControl 1 } sle2ErpsPhyRingControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "The status of user command" ::= { sle2ErpsPhyRingControl 2 } sle2ErpsPhyRingControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum time for the manager for a long running user command" ::= { sle2ErpsPhyRingControl 3 } sle2ErpsPhyRingControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "The time stamp of the last command(end of command)" ::= { sle2ErpsPhyRingControl 4 } sle2ErpsPhyRingControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-write STATUS current DESCRIPTION "Result of the last command." ::= { sle2ErpsPhyRingControl 5 } sle2ErpsPhyRingControlBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32 | 100) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates primary bridgegroup id 1: default bridge id 100: backbone " ::= { sle2ErpsPhyRingControl 6 } sle2ErpsPhyRingControName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Physical ring name (maximum 37 characters)." ::= { sle2ErpsPhyRingControl 7 } sle2ErpsPhyRingControEastPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Ring Node’s east interface index" ::= { sle2ErpsPhyRingControl 8 } sle2ErpsPhyRingControWestPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Ring Node’s west interface index" ::= { sle2ErpsPhyRingControl 9 } sle2ErpsPhyRingControlMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2ErpsPhyRingControl 10 } sle2ErpsPhyRingControlRmepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2ErpsPhyRingControl 11 } sleErpsPhyRingNotification OBJECT IDENTIFIER ::= { sle2ErpsPhyRing 3 } sle2ErpsPhyRingCreated NOTIFICATION-TYPE OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName } STATUS current DESCRIPTION "createPhyRing" ::= { sleErpsPhyRingNotification 1 } sle2ErpsPhyRingDestoryed NOTIFICATION-TYPE OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingControlBridgeId, sle2ErpsPhyRingControName } STATUS current DESCRIPTION "destoryPhyRing" ::= { sleErpsPhyRingNotification 2 } sle2ErpsPhyRingEastPortAdded NOTIFICATION-TYPE OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName, sle2ErpsPhyRingEastPort } STATUS current DESCRIPTION "Description." ::= { sleErpsPhyRingNotification 3 } sle2ErpsPhyRingEastPortDeleted NOTIFICATION-TYPE OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingControlBridgeId, sle2ErpsPhyRingControName } STATUS current DESCRIPTION "Description." ::= { sleErpsPhyRingNotification 4 } sle2ErpsPhyRingWestPortAdded NOTIFICATION-TYPE OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName, sle2ErpsPhyRingWestPort } STATUS current DESCRIPTION "Description." ::= { sleErpsPhyRingNotification 5 } sle2ErpsPhyRingWestPortDeleted NOTIFICATION-TYPE OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingControlBridgeId, sle2ErpsPhyRingControName } STATUS current DESCRIPTION "Description." ::= { sleErpsPhyRingNotification 6 } sle2ErpsPhyRingEastMepIdAdded NOTIFICATION-TYPE OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName, sle2ErpsPhyRingEastMepId, sle2ErpsPhyRingEastRmepId } STATUS current DESCRIPTION "Description." ::= { sleErpsPhyRingNotification 7 } sle2ErpsPhyRingEastMepIdDeleted NOTIFICATION-TYPE OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingControlBridgeId, sle2ErpsPhyRingControName } STATUS current DESCRIPTION "Description." ::= { sleErpsPhyRingNotification 8 } sle2ErpsPhyRingWestMepIdAdded NOTIFICATION-TYPE OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName, sle2ErpsPhyRingWestMepId, sle2ErpsPhyRingWestRmepId } STATUS current DESCRIPTION "Description." ::= { sleErpsPhyRingNotification 9 } sle2ErpsPhyRingWestMepIdDeleted NOTIFICATION-TYPE OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingControlBridgeId, sle2ErpsPhyRingControName } STATUS current DESCRIPTION "Description." ::= { sleErpsPhyRingNotification 10 } sle2ErpsProfile OBJECT IDENTIFIER ::= { sle2Erps 2 } sle2ErpsProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2ErpsProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2ErpsProfile 1 } sle2ErpsProfileEntry OBJECT-TYPE SYNTAX Sle2ErpsProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2ErpsProfileBridgeId, sle2ErpsProfileName } ::= { sle2ErpsProfileTable 1 } Sle2ErpsProfileEntry ::= SEQUENCE { sle2ErpsProfileBridgeId Integer32, sle2ErpsProfileName OCTET STRING, sle2ErpsProfileHoldOffTime INTEGER, sle2ErpsProfileGuardTime INTEGER, sle2ErpsProfileWaitToRestore INTEGER, sle2ErpsProfileNonRevertive INTEGER } sle2ErpsProfileBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32 | 100) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates primary bridgegroup id 1: default bridge id 100: backbone " ::= { sle2ErpsProfileEntry 1 } sle2ErpsProfileName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Profile name (maximum 32 characters)." ::= { sle2ErpsProfileEntry 2 } sle2ErpsProfileHoldOffTime OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the hold-off time default : 0 " DEFVAL { 0 } ::= { sle2ErpsProfileEntry 3 } sle2ErpsProfileGuardTime OBJECT-TYPE SYNTAX INTEGER (10..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the guard time default : 500 " DEFVAL { 500 } ::= { sle2ErpsProfileEntry 4 } sle2ErpsProfileWaitToRestore OBJECT-TYPE SYNTAX INTEGER (1..12) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the wait-to-restore time default : 5 " DEFVAL { 5 } ::= { sle2ErpsProfileEntry 5 } sle2ErpsProfileNonRevertive OBJECT-TYPE SYNTAX INTEGER { revertive(0), nonRevertive(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Non-Revertive or Revertive." ::= { sle2ErpsProfileEntry 6 } sle2ErpsProfileControl OBJECT IDENTIFIER ::= { sle2ErpsProfile 2 } sle2ErpsProfileControlRequest OBJECT-TYPE SYNTAX INTEGER { createErpsProfile(1), destroyErpsProfile(2), setProfileTimer(3), setNoneRevertive(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The request of a user command" ::= { sle2ErpsProfileControl 1 } sle2ErpsProfileControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "The status of user command" ::= { sle2ErpsProfileControl 2 } sle2ErpsProfileControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum time for the manager for a long running user command" ::= { sle2ErpsProfileControl 3 } sle2ErpsProfileControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-write STATUS current DESCRIPTION "The time stamp of the last command(end of command)" ::= { sle2ErpsProfileControl 4 } sle2ErpsProfileControlReqResult OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-write STATUS current DESCRIPTION "Result of the last command." ::= { sle2ErpsProfileControl 5 } sle2ErpsProfileControlBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32 | 100) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates primary bridgegroup id 1: default bridge id 100: backbone " ::= { sle2ErpsProfileControl 6 } sle2ErpsProfileControlName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Profile name (maximum 32 characters)." ::= { sle2ErpsProfileControl 7 } sle2ErpsProfileControlHoldOffTime OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the hold-off time default : 0 " DEFVAL { 0 } ::= { sle2ErpsProfileControl 8 } sle2ErpsProfileControlGuardTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the guard time default : 500 " DEFVAL { 500 } ::= { sle2ErpsProfileControl 9 } sle2ErpsProfileControlWaitToRestore OBJECT-TYPE SYNTAX Integer32 (1..12) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the wait-to-restore time default : 5 " DEFVAL { 5 } ::= { sle2ErpsProfileControl 10 } sle2ErpsProfileControlNonRevertive OBJECT-TYPE SYNTAX INTEGER { revertive(0), nonRevertive(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Non-Revertive or Revertive." ::= { sle2ErpsProfileControl 11 } sle2ErpsProfileNotification OBJECT IDENTIFIER ::= { sle2ErpsProfile 3 } sle2ErpsProfileCreated NOTIFICATION-TYPE OBJECTS { sle2ErpsProfileControlRequest, sle2ErpsProfileControlReqResult, sle2ErpsProfileControlTimeStamp, sle2ErpsProfileBridgeId, sle2ErpsProfileName } STATUS current DESCRIPTION "createErpsProfile" ::= { sle2ErpsProfileNotification 1 } sle2ErpsProfileDestoryed NOTIFICATION-TYPE OBJECTS { sle2ErpsProfileControlRequest, sle2ErpsProfileControlReqResult, sle2ErpsProfileControlTimeStamp, sle2ErpsProfileControlBridgeId, sle2ErpsProfileControlName } STATUS current DESCRIPTION "destoryPhyRing" ::= { sle2ErpsProfileNotification 2 } sle2ErpsProfileTimerChanged NOTIFICATION-TYPE OBJECTS { sle2ErpsProfileControlRequest, sle2ErpsProfileControlReqResult, sle2ErpsProfileControlTimeStamp, sle2ErpsProfileBridgeId, sle2ErpsProfileName, sle2ErpsProfileHoldOffTime, sle2ErpsProfileGuardTime, sle2ErpsProfileWaitToRestore } STATUS current DESCRIPTION "setProfileTimer" ::= { sle2ErpsProfileNotification 3 } sle2ErpsProfileNoneRevertiveChanged NOTIFICATION-TYPE OBJECTS { sle2ErpsProfileControlRequest, sle2ErpsProfileControlReqResult, sle2ErpsProfileControlTimeStamp, sle2ErpsProfileBridgeId, sle2ErpsProfileName, sle2ErpsProfileNonRevertive } STATUS current DESCRIPTION "setNoneRevertive" ::= { sle2ErpsProfileNotification 4 } sle2ErpsInstance OBJECT IDENTIFIER ::= { sle2Erps 3 } sle2ErpsInstanceTable OBJECT-TYPE SYNTAX SEQUENCE OF Sle2ErpsInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { sle2ErpsInstance 1 } sle2ErpsInstanceEntry OBJECT-TYPE SYNTAX Sle2ErpsInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { sle2ErpsInstBridgeId, sle2ErpsInstName } ::= { sle2ErpsInstanceTable 1 } Sle2ErpsInstanceEntry ::= SEQUENCE { sle2ErpsInstBridgeId Integer32, sle2ErpsInstName OCTET STRING, sle2ErpsInstPhyRingName OCTET STRING, sle2ErpsInstProfileName OCTET STRING, sle2ErpsInstRingId Integer32, sle2ErpsInstLevel Integer32, sle2ErpsInstRplRole INTEGER, sle2ErpsInstRplRolePort INTEGER, sle2ErpsInstSubRingBlock INTEGER, sle2ErpsInstCtrlVlan Integer32, sle2ErpsInstTafficVlans OCTET STRING, sle2ErpsInstChannelMode INTEGER, sle2ErpsInstVChannelVid Integer32, sle2ErpsInstVChannelAttachInstName OCTET STRING, sle2ErpsInstPropagateTc INTEGER, sle2ErpsInstActive INTEGER, sle2ErpsInstStatus INTEGER, sle2ErpsInstEastIfindex Integer32, sle2ErpsInstEastPortStatus INTEGER, sle2ErpsInstWestIfindex Integer32, sle2ErpsInstWestPortStatus INTEGER, sle2ErpsInstVersion INTEGER, sle2ErpsInstDataTrafficInheritanceInstName OCTET STRING } sle2ErpsInstBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32 | 100) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates primary bridgegroup id 1: default bridge id 100: backbone " ::= { sle2ErpsInstanceEntry 1 } sle2ErpsInstName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The ERPS instance name." ::= { sle2ErpsInstanceEntry 2 } sle2ErpsInstPhyRingName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Physical ring name (maximum 37 characters). Indicates the sle2ErpsPhyRingName of sle2ErpsPhyRing table " ::= { sle2ErpsInstanceEntry 3 } sle2ErpsInstProfileName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Profile name (maximum 32 characters). Indicates the sle2ErpsProfileName of sle2ErpsProfile Table. " ::= { sle2ErpsInstanceEntry 4 } sle2ErpsInstRingId OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring’s ID" ::= { sle2ErpsInstanceEntry 5 } sle2ErpsInstLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring’s Level" ::= { sle2ErpsInstanceEntry 6 } sle2ErpsInstRplRole OBJECT-TYPE SYNTAX INTEGER { none(0), owner(1), neighbour(2), nextNeighbor(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring Node’s Role" ::= { sle2ErpsInstanceEntry 7 } sle2ErpsInstRplRolePort OBJECT-TYPE SYNTAX INTEGER { none(0), east(1), west(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring’s RPL port" ::= { sle2ErpsInstanceEntry 8 } sle2ErpsInstSubRingBlock OBJECT-TYPE SYNTAX INTEGER { none(0), east(1), west(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Sub-Ring’s RPL port. Indicates the Ring’s interconnection port. You should only give this command on interconnection nodes. " ::= { sle2ErpsInstanceEntry 9 } sle2ErpsInstCtrlVlan OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring Node’s control-vlan" ::= { sle2ErpsInstanceEntry 10 } sle2ErpsInstTafficVlans OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Ring Node’s traffic-vlans" ::= { sle2ErpsInstanceEntry 11 } sle2ErpsInstChannelMode OBJECT-TYPE SYNTAX INTEGER { none(0), nonVirtualChannel(1), virtualChannel(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2ErpsInstanceEntry 12 } sle2ErpsInstVChannelVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "VLAN identifier" ::= { sle2ErpsInstanceEntry 13 } sle2ErpsInstVChannelAttachInstName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Major instance name." ::= { sle2ErpsInstanceEntry 14 } sle2ErpsInstPropagateTc OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2ErpsInstanceEntry 15 } sle2ErpsInstActive OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2ErpsInstanceEntry 16 } sle2ErpsInstStatus OBJECT-TYPE SYNTAX INTEGER { none(0), init(1), pending(2), idle(3), foreced(4), protected(5), manual(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the erps instance status." ::= { sle2ErpsInstanceEntry 17 } sle2ErpsInstEastIfindex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2ErpsInstanceEntry 18 } sle2ErpsInstEastPortStatus OBJECT-TYPE SYNTAX INTEGER { none(0), unblocked(1), blocked(2), failed(3), blockedFailed(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the east interface status." ::= { sle2ErpsInstanceEntry 19 } sle2ErpsInstWestIfindex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sle2ErpsInstanceEntry 20 } sle2ErpsInstWestPortStatus OBJECT-TYPE SYNTAX INTEGER { none(0), unblocked(1), blocked(2), failed(3), blockedFailed(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the west interface status." ::= { sle2ErpsInstanceEntry 21 } sle2ErpsInstVersion OBJECT-TYPE SYNTAX INTEGER { none(0), version1(1), version2(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the west interface erps version. Version 1: ITU-T Recommendation G.8032/Y.1344 2008 Version 2: ITU-T Recommendation G.8032/Y.1344 2008 " ::= { sle2ErpsInstanceEntry 22 } sle2ErpsInstDataTrafficInheritanceInstName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The inheritance ERPS instance name. (temporary)" ::= { sle2ErpsInstanceEntry 23 } sle2ErpsInstanceControl OBJECT IDENTIFIER ::= { sle2ErpsInstance 2 } sle2ErpsInstControlRequest OBJECT-TYPE SYNTAX INTEGER { createErpsInstance(1), destoryErpsInstance(2), addErpsInstPhyRing(3), delErpsInstPhyRing(4), addErpsInstProfile(5), delErpsInstProfile(6), setErpsInstRingId(7), setErpsInstLevel(8), setErpsInstRpl(9), addErpsInstSubRing(10), delErpsInstSubRing(11), addErpsInstCtrlVlan(12), delErpsInstCtrlVlan(13), addErpsInstTrafficVlan(14), delErpsInstTrafficVlan(15), addErpsInstVitrualChannel(16), delErpsInstVitrualChannel(17), addErpsInstNoneVirtualChanel(18), delErpsInstNoneVirtualChanel(19), setErpsInstForcedSwitch(20), setErpsInstManualSwitch(21), clearErpsInst(22), setErpsInstPropagateTc(23), setErpsInstVersion(24), setErpsInstActive(25), setVlanInheritanceDataTraffic(26), delVlanInheritanceDataTraffic(27) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2ErpsInstanceControl 1 } sle2ErpsInstControlStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2ErpsInstanceControl 2 } sle2ErpsInstControlTimer OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2ErpsInstanceControl 3 } sle2ErpsInstControlTimeStamp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2ErpsInstanceControl 4 } sle2ErpsInstControlReqResult OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2ErpsInstanceControl 5 } sle2ErpsInstControlBridgeId OBJECT-TYPE SYNTAX Integer32 (1..32 | 100) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates primary bridgegroup id 1: default bridge id 100: backbone " ::= { sle2ErpsInstanceControl 6 } sle2ErpsInstControlName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "The ERPS instance name." ::= { sle2ErpsInstanceControl 7 } sle2ErpsInstControlPhyRingName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Physical ring name (maximum 37 characters). Indicates the sle2ErpsPhyRingName of sle2ErpsPhyRing table " ::= { sle2ErpsInstanceControl 8 } sle2ErpsInstControlProfileName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Profile name (maximum 32 characters). Indicates the sle2ErpsProfileName of sle2ErpsProfile Table. " ::= { sle2ErpsInstanceControl 9 } sle2ErpsInstControlRingId OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Ring’s ID" ::= { sle2ErpsInstanceControl 10 } sle2ErpsInstControlLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Ring’s Level" ::= { sle2ErpsInstanceControl 11 } sle2ErpsInstControlRplRole OBJECT-TYPE SYNTAX INTEGER { none(0), owner(1), neighbour(2), nextNeighbor(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Ring Node’s Role" ::= { sle2ErpsInstanceControl 12 } sle2ErpsInstControlRplRolePort OBJECT-TYPE SYNTAX INTEGER { east(1), west(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Ring’s RPL port" ::= { sle2ErpsInstanceControl 13 } sle2ErpsInstControlSubRingBlock OBJECT-TYPE SYNTAX INTEGER { east(1), west(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Sub-Ring’s RPL port. Indicates the Ring’s interconnection port. You should only give this command on interconnection nodes. " ::= { sle2ErpsInstanceControl 14 } sle2ErpsInstControlCtrlVlan OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Ring Node’s control-vlan" ::= { sle2ErpsInstanceControl 15 } sle2ErpsInstControlTafficVlans OBJECT-TYPE SYNTAX Integer32 (2..4092) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Ring Node traffic-vlans" ::= { sle2ErpsInstanceControl 16 } sle2ErpsInstControlVChannelVid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "VLAN identifier" ::= { sle2ErpsInstanceControl 17 } sle2ErpsInstControlVChannelAttachInstName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Major instance name." ::= { sle2ErpsInstanceControl 18 } sle2ErpsInstControlForcedSwitch OBJECT-TYPE SYNTAX INTEGER { east(1), west(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Forced Switch" ::= { sle2ErpsInstanceControl 19 } sle2ErpsInstControlManualSwitch OBJECT-TYPE SYNTAX INTEGER { east(1), west(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the Manual Switch" ::= { sle2ErpsInstanceControl 20 } sle2ErpsInstControlPropagateTc OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2ErpsInstanceControl 21 } sle2ErpsInstControlVersion OBJECT-TYPE SYNTAX INTEGER { version1(1), version2(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the version. Version 0: ITU-T Recommendation G.8032/Y.1344 2008 Version 1: ITU-T Recommendation G.8032/Y.1344 2008 " ::= { sle2ErpsInstanceControl 22 } sle2ErpsInstControlActive OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sle2ErpsInstanceControl 23 } sle2ErpsInstControlDataTrafficInheritanceInstName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "The inheritance ERPS instance name. (temporary)" ::= { sle2ErpsInstanceControl 24 } sle2ErpsInstanceNotification OBJECT IDENTIFIER ::= { sle2ErpsInstance 3 } sle2ErpsInstCreated NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName } STATUS current DESCRIPTION "createErpsInstance" ::= { sle2ErpsInstanceNotification 1 } sle2ErpsInstDestoryed NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName } STATUS current DESCRIPTION "destoryErpsInstance " ::= { sle2ErpsInstanceNotification 2 } sle2ErpsInstPhyRingAdded NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName, sle2ErpsInstPhyRingName } STATUS current DESCRIPTION "setErpsPhyRing" ::= { sle2ErpsInstanceNotification 3 } sle2ErpsInstPhyRingDeleted NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName } STATUS current DESCRIPTION "Description." ::= { sle2ErpsInstanceNotification 4 } sle2ErpsInstProfileAdded NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName, sle2ErpsInstProfileName } STATUS current DESCRIPTION "setErpsProfile" ::= { sle2ErpsInstanceNotification 5 } sle2ErpsInstProfileDeleted NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName } STATUS current DESCRIPTION "Description." ::= { sle2ErpsInstanceNotification 6 } sle2ErpsInstRingIdChanged NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName, sle2ErpsInstRingId } STATUS current DESCRIPTION "setErpsInstRingId" ::= { sle2ErpsInstanceNotification 7 } sle2ErpsInstLevelChanged NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName, sle2ErpsInstLevel } STATUS current DESCRIPTION "setErpsInstLevel" ::= { sle2ErpsInstanceNotification 8 } sle2ErpsInstRplRoleChanged NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName, sle2ErpsInstRplRole, sle2ErpsInstRplRolePort } STATUS current DESCRIPTION "setErpsInstRpl" ::= { sle2ErpsInstanceNotification 9 } sle2ErpsInstSubRingAdded NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName, sle2ErpsInstSubRingBlock } STATUS current DESCRIPTION "addErpsInstRubRing" ::= { sle2ErpsInstanceNotification 10 } sle2ErpsInstSubRingDeleted NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName } STATUS current DESCRIPTION "delErpsInstRubRing" ::= { sle2ErpsInstanceNotification 11 } sle2ErpsInstCtrlVlanAdded NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName, sle2ErpsInstCtrlVlan } STATUS current DESCRIPTION "addErpsInstCtrlVlan" ::= { sle2ErpsInstanceNotification 12 } sle2ErpsInstCtrlVlanDeleted NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName, sle2ErpsInstControlCtrlVlan } STATUS current DESCRIPTION "delErpsInstCtrlVlan" ::= { sle2ErpsInstanceNotification 13 } sle2ErpsInstDataTrafficVlanAdded NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName, sle2ErpsInstTafficVlans } STATUS current DESCRIPTION "addErpsInstTrafficVlan" ::= { sle2ErpsInstanceNotification 14 } sle2ErpsInstDataTrafficVlanDeleted NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName, sle2ErpsInstControlTafficVlans } STATUS current DESCRIPTION "delErpsInstTrafficVlan" ::= { sle2ErpsInstanceNotification 15 } sle2ErpsInstVitrualChannelAdded NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName, sle2ErpsInstVChannelVid, sle2ErpsInstVChannelAttachInstName, sle2ErpsInstChannelMode } STATUS current DESCRIPTION "setErpsInstVitrualChannel" ::= { sle2ErpsInstanceNotification 16 } sle2ErpsInstVitrualChannelDeleted NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName } STATUS current DESCRIPTION "Description." ::= { sle2ErpsInstanceNotification 17 } sle2ErpsInstNoneVirtualChannelAdded NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName, sle2ErpsInstChannelMode } STATUS current DESCRIPTION "setErpsInstNoneVirtualChanel" ::= { sle2ErpsInstanceNotification 18 } sle2ErpsInstNoneVirtualChannelDeleted NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName } STATUS current DESCRIPTION "Description." ::= { sle2ErpsInstanceNotification 19 } sle2ErpsInstForcedSwichChanged NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName, sle2ErpsInstControlForcedSwitch } STATUS current DESCRIPTION "setErpsInstForcedSwitch" ::= { sle2ErpsInstanceNotification 20 } sle2ErpsInstManualSwichChanged NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName, sle2ErpsInstControlManualSwitch } STATUS current DESCRIPTION "setErpsInstManualSwitch" ::= { sle2ErpsInstanceNotification 21 } sle2ErpsInstClearChanged NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName } STATUS current DESCRIPTION "setErpsInstClear" ::= { sle2ErpsInstanceNotification 22 } sle2ErpsInstPropagateTcChanged NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName, sle2ErpsInstPropagateTc } STATUS current DESCRIPTION "setErpsInstPropagateTc" ::= { sle2ErpsInstanceNotification 23 } sle2ErpInstVersionChanged NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName, sle2ErpsInstEastVersion, sle2ErpsInstWestVersion } STATUS current DESCRIPTION "setErpsInstVersion" ::= { sle2ErpsInstanceNotification 24 } sle2ErpInstActiveChanged NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName, sle2ErpsInstActive } STATUS current DESCRIPTION "Description." ::= { sle2ErpsInstanceNotification 25 } sle2ErpInstDataTrafficInheritanceInstNameChanged NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstDataTrafficInheritanceInstName, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName } STATUS current DESCRIPTION "Temp" ::= { sle2ErpsInstanceNotification 26 } sle2ErpInstDataTrafficInheritanceInstNameDeleted NOTIFICATION-TYPE OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstDataTrafficInheritanceInstName, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName } STATUS current DESCRIPTION "Temp" ::= { sle2ErpsInstanceNotification 27 } sleFaultMgmtGroup OBJECT-GROUP OBJECTS { sleFaultDefaultSeverity, sleFaultCriteriaSeverity, sleFaultNotifiyActivity, sleFaultControlRequest, sleFaultControlStatus, sleFaultControlTimer, sleFaultControlTimeStamp, sleFaultControlReqResult, sleFaultControlDefaultSeverity, sleFaultControlCriteriaSeverity, sleFaultControlNotifiyActivity, sleAlarmSeverityIndex, sleAlarmSeverityValue, sleAlarmSeverityControlRequest, sleAlarmSeverityControlStatus, sleAlarmSeverityControlTimer, sleAlarmSeverityControlTimeStamp, sleAlarmSeverityControlReqResult, sleAlarmSeverityControlIndex, sleAlarmSeverityControlValue, sleAlarmSpecificCode, sleAlarmReportingSourceType, sleAlarmReportingSource, sleAlarmSpecificSeverity, sleAlarmSpecificProblem, sleAlarmSpecificProblemText, sleAlarmTimeAndDate, sleAlarmHistoryIndex, sleAlarmHistorySpecific, sleAlarmHistorySeverity, sleAlarmHistoryText, sleAlarmHistoryTime, sleAlarmHistoryControlRequest, sleAlarmHistoryControlStatus, sleAlarmHistoryControlTimer, sleAlarmHistoryControlTimeStamp, sleAlarmHistoryControlReqResult, sleOamPortIndex, sleOamMuxAction, sleOamParAction, sleOamAdminState, sleOamMode, sleOamUnidirectionMode, sleOamFunctionsSupported, sleOamPeerStatus, sleOamPeerMacAddress, sleOamPeerMode, sleOamPeerFunctionsSupported, sleOamRemLoopback, sleOamControlRequest, sleOamControlStatus, sleOamControlTimer, sleOamControlTimeStamp, sleOamControlReqResult, sleOamControlIndex, sleOamControlPortAdminState, sleOamControlPortMode, sleOamControlPortUnidirectionMode, sleOamControlPortRemLoopback, sleAdvaFSPOperationMode, sleAdvaActiveNetworkInterface, sleAdvaForceNetworkInterface, sleAdvaReportingInterval, sleAdvaNEMIFitted, sleAdvaForceReset, sleAdvaManagerAddress, sleAdvaMinRailVoltageThreshold, sleAdvaMaxRailVoltageThreshold, sleAdvaTemperatureThreshold, sleAdvaPartNumber, sleAdvaSerialNumber, sleAdvaFirmwareVersion, sleAdvaFPGAVersion, sleAdvaHardwareRevision, sleAdvaCLEICode, sleAdvaTemperature, sleAdvaRailVoltage, sleAdvaPSUStates, sleAdvaPSUType, sleAdvaFansFitted, sleAdvaFanState, sleAdvaTransmitMode, sleAdvaSystemControlRequest, sleAdvaSystemControlStatus, sleAdvaSystemControlTimer, sleAdvaSystemControlTimeStamp, sleAdvaSystemControlReqResult, sleAdvaSystemControlPortIndex, sleAdvaSystemControlFSPOperationMode, sleAdvaSystemControlForceNetworkInterface, sleAdvaSystemControlReportingInterval, sleAdvaSystemControlForceReset, sleAdvaSystemControlMinRailVoltageThreshold, sleAdvaSystemControlMaxRailVoltageThreshold, sleAdvaSystemControlTemperatureThreshold, sleAdvaSystemControlTransmitMode, sleAdvaRemInstance, sleAdvaOperationalStatus, sleAdvaLineSpeed, sleAdvaMACAddress, sleAdvaConnectorType, sleAdvaAutonegiotation, sleAdvaLinkLossForwarding, sleAdvaAdminState, sleAdvaRemoteInterfaceIndex, sleAdvaUserDefinedString, sleAdvaRemoteSignalling, sleAdvaConfiguration, sleAdvaLocalTechnologyAbility, sleAdvaAdvertisedTechnologyAbility, sleAdvaReceivedTechnologyAbility, sleAdvaLocalSectorAbility, sleAdvaAdvertisedSectorAbility, sleAdvaReceivedSectorAbility, sleAdvaDuplexCapabilities, sleAdvaPHYType, sleAdvaPHYTypeList, sleAdvaMIIDetect, sleAdvaPHYState, sleAdvaGoodFramesTransmitted, sleAdvaSingleCollisionFrames, sleAdvaMultipleCollisionFrames, sleAdvaGoodFramesReceived, sleAdvaFCSErrors, sleAdvaAlignmentErrors, sleAdvaFramesTooLong, sleAdvaBytesTransmitted, sleAdvaBytesReceived, sleAdvaSymbolErrors, sleAdvaGeneralControlRequest, sleAdvaGeneralControlStatus, sleAdvaGeneralControlTimer, sleAdvaGeneralControlTimeStamp, sleAdvaGeneralControlReqResult, sleAdvaGeneralControlPortIndex, sleAdvaGeneralControlRemInstance, sleAdvaGeneralControlLineSpeed, sleAdvaGeneralControlAutonegiotation, sleAdvaGeneralControlLinkLossForwarding, sleAdvaGeneralControlUserDefinedString, sleAdvaGeneralControlAdvertisedTechnologyAbility, sleAdvaGeneralControlAdvertisedSectorAbility, sleAdvaModuleType, sleAdvaModulePartNumber, sleAdvaModuleSerialNumber, sleAdvaModuleFirmwareVersion, sleAdvaModuleSoftwareVersion, sleAdvaModuleHardwareRevision, sleAdvaModuleCLEICode, sleAdvaOpticalThresholdLevel, sleAdvaLinkLength1, sleAdvaLinkLength2, sleAdvaLinkLength3, sleAdvaLinkLength4, sleAdvaLinkLengthCu, sleAdvaWaveLength, sleAdvaLaserBias, sleAdvaTransmitPower, sleAdvaReceivePower, sleAdvaLaserTxTemperature, sleAdvaOpticalControlRequest, sleAdvaOpticalControlStatus, sleAdvaOpticalControlTimer, sleAdvaOpticalControlTimeStamp, sleAdvaOpticalControlReqResult, sleAdvaOpticalControlPortIndex, sleAdvaOpticalControlRemInstance, sleAdvaOpticalControlThresholdLevel, sleAdvaAdminStatus, sleAdvaMode, sleAdvaRemMACAddress, sleAdvaRemConfig, sleAdvaRemPduConfig, sleAdvaLocFlags, sleAdvaRemFlags, sleAdvaRemState, sleAdvaRemVendorOUI, sleAdvaRemDeviceNumber, sleAdvaRemVendorVersion, sleAdvaLocErrSymbolPeriodEventConfig, sleAdvaLocErrFrameEventConfig, sleAdvaLocErrFramePeriodEventConfig, sleAdvaLocErrFrameSecsSummaryEventConfig, sleAdvaPDUsTx, sleAdvaPDUsRx, sleAdvaUnsupportedCodesRx, sleAdvaInfoPDUsTx, sleAdvaInfoPDUsRx, sleAdvaEventNotificationPDUsTx, sleAdvaUniqueEventNotificationPDUsTx, sleAdvaDupEventNotificationPDUsTx, sleAdvaLoopbackControlPDUsTx, sleAdvaLoopbackControlPDUsRx, sleAdvaVariableRequestPDUsTx, sleAdvaVariableRequestPDUsRx, sleAdvaVariableResponsePDUsTx, sleAdvaVariableResponsePDUsRx, sleAdvaVendorPDUsTx, sleAdvaVendorPDUsRx, sleAdvaRemFramesLostDuetoOAMErr, sleAdvaLocErrSymbolPeriodEvent, sleAdvaLocErrFrameSecsEvent, sleAdvaLocErrFramePeriodEvent, sleAdvaLocErrFrameSecsSummaryEvent, sleAdvaRemErrSymbolPeriodEvent, sleAdvaRemErrFrameSecsEvent, sleAdvaRemoteErrorFramePeriodEvent, sleAdvaRemoteErrorFrameSecsSummaryEvent, sleAdvaOamControlRequest, sleAdvaOamControlStatus, sleAdvaOamControlTimer, sleAdvaOamControlTimeStamp, sleAdvaOamControlReqResult, sleAdvaOamControlPortIndex, sleAdvaOamControlRemInstance, sleAdvaOamControlAdminStatus, sleAlarmHistorySeqNum, sleAlarmSpecificSeqNum, sleFaultNextSeqNum, sleAlarmLEDType, sleAlarmLEDStatus, sleAlarmLEDLevel, sleAlarmLEDLevelIndex, sleAlarmLEDLevelBlock, sleAlarmLEDControlRequest, sleAlarmLEDControlStatus, sleAlarmLEDControlTimer, sleAlarmLEDControlTimeStamp, sleAlarmLEDControlReqResult, sleAlarmLEDControlType, sleAlarmLEDControlLevel, sleAlarmLEDControlBlock, sleAlarmLEDLevelOperStatus, sleY1731Enable, sleY1731TrunkEnable, sleY1731LtrCacheHoldTime, sleY1731LtrCacheSize, sleY1731SnmpServerTraps, sleY1731XcheckStartDelay, sleY1731DefaultMegLevel, sleY1731DefaultMegMhfCreation, sleY1731PduToCfm, sleY1731DedicatedVlan, sleY1731BaseControlRequest, sleY1731BaseControlStatus, sleY1731BaseControlTimer, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlEnable, sleY1731BaseControlTrunkEnable, sleY1731BaseControlLtrCacheHoldTime, sleY1731BaseControlLtrCacheSize, sleY1731BaseControlSnmpServerTraps, sleY1731BaseControlXcheckStartDelay, sleY1731BaseControlDefaultMegLevel, sleY1731BaseControlDefaultMegMhfCreation, sleY1731BaseControlPduToCfm, sleY1731BaseControlDedicatedVlan, sleY1731MegIndex, sleY1731MegName, sleY1731MegLevel, sleY1731MegVid, sleY1731MegMepEnable, sleY1731MegCcEnable, sleY1731MegCcInterval, sleY1731MegCcPriority, sleY1731MegCcLossThreshold, sleY1731MegCcHoldTime, sleY1731MegFaultPriority, sleY1731MegFaultKeepTime, sleY1731MegFaultClearTime, sleY1731MegXcheckEnable, sleY1731MegAisEnable, sleY1731MegAisTransmitEnable, sleY1731MegAisInterval, sleY1731MegAisLevel, sleY1731MegAisPriority, sleY1731MegLckEnable, sleY1731MegLckTransmitEnable, sleY1731MegLckInterval, sleY1731MegLckLevel, sleY1731MegLckPriority, sleY1731MegOutOfService, sleY1731MegRapsEnable, sleY1731MegRapsRplOwner, sleY1731MegRapsEastPort, sleY1731MegRapsWestPort, sleY1731MegRapsRplPort, sleY1731MegRapsHoldOffTime, sleY1731MegRapsGuardTime, sleY1731MegRapsWaitToRestore, sleY1731MegRapsState, sleY1731MegControlRequest, sleY1731MegControlStatus, sleY1731MegControlTimer, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName, sleY1731MegControlLevel, sleY1731MegControlVid, sleY1731MegControlMepEnable, sleY1731MegControlCcEnable, sleY1731MegControlCcInterval, sleY1731MegControlCcPriority, sleY1731MegControlCcLossThreshold, sleY1731MegControlCcHoldTime, sleY1731MegControlFaultPriority, sleY1731MegControlFaultKeepTime, sleY1731MegControlFaultClearTime, sleY1731MegControlXcheckEnable, sleY1731MegControlAisEnable, sleY1731MegControlAisTransmitEnable, sleY1731MegControlAisInterval, sleY1731MegControlAisLevel, sleY1731MegControlAisPriority, sleY1731MegControlLckEnable, sleY1731MegControlLckTransmitEnable, sleY1731MegControlLckInterval, sleY1731MegControlLckLevel, sleY1731MegControlLckPriority, sleY1731MegControlOutOfService, sleY1731MegControlRapsEnable, sleY1731MegControlRapsRplOwner, sleY1731MegControlRapsEastPort, sleY1731MegControlRapsWestPort, sleY1731MegControlRapsRplPort, sleY1731MegControlRapsHoldOffTime, sleY1731MegControlRapsGuardTime, sleY1731MegControlRapsWaitToRestore, sleY1731MepIdentifier, sleY1731MepIfIndex, sleY1731MepDirection, sleY1731MepEnable, sleY1731MepFngState, sleY1731MepCcEnable, sleY1731MepMacAddress, sleY1731MepFaultPriority, sleY1731MepFaultKeepTime, sleY1731MepFaultClearTime, sleY1731MepHighestPrDefect, sleY1731MepAisEnable, sleY1731MepAisTransmitEnable, sleY1731MepLckEnable, sleY1731MepLckTransmitEnable, sleY1731MepOutOfService, sleY1731MepDlmEnabledRmep, sleY1731MepDefects, sleY1731MepCcmSequenceErrors, sleY1731MepCciSentCcms, sleY1731MepNextLbmTransId, sleY1731MepLbrIn, sleY1731MepLbrInOutOfOrder, sleY1731MepTstLbrInBitError, sleY1731MepTstLbrInCrcError, sleY1731MepLtmNextSeqNumber, sleY1731MepUnexpLtrIn, sleY1731MepLbrOut, sleY1731MepTmLbrFirstLostId, sleY1731MepTmLbrMaxRate, sleY1731MepCcmFrameLossNearMin, sleY1731MepCcmFrameLossNearMax, sleY1731MepCcmFrameLossNearSum, sleY1731MepCcmFrameLossFarMin, sleY1731MepCcmFrameLossFarMax, sleY1731MepCcmFrameLossFarSum, sleY1731MepControlRequest, sleY1731MepControlStatus, sleY1731MepControlTimer, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex, sleY1731MepControlIfIndex, sleY1731MepControlDirection, sleY1731MepControlEnable, sleY1731MepControlCcEnable, sleY1731MepControlFaultPriority, sleY1731MepControlFaultKeepTime, sleY1731MepControlFaultClearTime, sleY1731MepControlAisEnable, sleY1731MepControlAisTransmitEnable, sleY1731MepControlLckEnable, sleY1731MepControlLckTransmitEnable, sleY1731MepControlOutOfService, sleY1731MepControlDlmEnabledRmep, sleY1731MepControlTransmitLbmIsUnicast, sleY1731MepControlTransmitLbmDestMacAddress, sleY1731MepControlTransmitLbmDestMepId, sleY1731MepControlTransmitLbmDestIsMepId, sleY1731MepControlTransmitLbmCount, sleY1731MepControlTransmitLbmInterval, sleY1731MepControlTransmitLbmTimeout, sleY1731MepControlTransmitLbmPriority, sleY1731MepControlTransmitLbmLength, sleY1731MepControlTransmitLtmTargetMacAddress, sleY1731MepControlTransmitLtmTargetMepId, sleY1731MepControlTransmitLtmTargetIsMepId, sleY1731MepControlTransmitLtmFlags, sleY1731MepControlTransmitLtmTtl, sleY1731MepControlTransmitLtmPriority, sleY1731MepControlTransmitTstLbmDestMepId, sleY1731MepControlTransmitTstLbmDuration, sleY1731MepControlTransmitTstLbmInterval, sleY1731MepControlTransmitTstLbmTimeout, sleY1731MepControlTransmitTstLbmPriority, sleY1731MepControlTransmitTstLbmLength, sleY1731MepControlTransmitTstLbmPattern, sleY1731MepControlTransmitTmLbmDestMepId, sleY1731MepControlTransmitTmLbmDuration, sleY1731MepControlTransmitTmLbmPartDuration, sleY1731MepControlTransmitTmLbmStartRate, sleY1731MepControlTransmitTmLbmIncRate, sleY1731MepControlTransmitTmLbmTimeout, sleY1731MepControlTransmitTmLbmPriority, sleY1731MepControlTransmitTmLbmLength, sleY1731MepControlTransmitTmLbmPattern, sleY1731MepControlTransmitTstIsUnicast, sleY1731MepControlTransmitTstDestMepId, sleY1731MepControlTransmitTstDuration, sleY1731MepControlTransmitTstInterval, sleY1731MepControlTransmitTstPriority, sleY1731MepControlTransmitTstLength, sleY1731MepControlTransmitTstPattern, sleY1731MepControlReceiveTstDuration, sleY1731MepControlTransmitTmTstIsUnicast, sleY1731MepControlTransmitTmTstDestMepId, sleY1731MepControlTransmitTmTstDuration, sleY1731MepControlTransmitTmTstPartDuration, sleY1731MepControlTransmitTmTstStartRate, sleY1731MepControlTransmitTmTstIncRate, sleY1731MepControlTransmitTmTstTimeout, sleY1731MepControlTransmitTmTstPriority, sleY1731MepControlTransmitTmTstLength, sleY1731MepControlTransmitTmTstPattern, sleY1731MepControlReceiveTmTstDuration, sleY1731MepControlTransmitLmmIsUnicast, sleY1731MepControlTransmitLmmDestMepId, sleY1731MepControlTransmitLmmDuration, sleY1731MepControlTransmitLmmInterval, sleY1731MepControlTransmitLmmTimeout, sleY1731MepControlTransmitLmmPriority, sleY1731MepControlTransmit1dmIsUnicast, sleY1731MepControlTransmit1dmDestMepId, sleY1731MepControlTransmit1dmDuration, sleY1731MepControlTransmit1dmInterval, sleY1731MepControlTransmit1dmPriority, sleY1731MepControlReceive1dmDuration, sleY1731MepControlTransmitDmmIsUnicast, sleY1731MepControlTransmitDmmDestMepId, sleY1731MepControlTransmitDmmDuration, sleY1731MepControlTransmitDmmInterval, sleY1731MepControlTransmitDmmTimeout, sleY1731MepControlTransmitDmmPriority, sleY1731MipPort, sleY1731MipLevel, sleY1731MipType, sleY1731MipControlRequest, sleY1731MipControlStatus, sleY1731MipControlTimer, sleY1731MipControlTimeStamp, sleY1731MipControlReqResult, sleY1731MipControlPort, sleY1731MipControlLevel, sleY1731XcheckMepIdentifier, sleY1731XcheckMepState, sleY1731XcheckControlRequest, sleY1731XcheckControlStatus, sleY1731XcheckControlTimer, sleY1731XcheckControlTimeStamp, sleY1731XcheckControlReqResult, sleY1731XcheckControlMepIdentifier, sleY1731XcheckControlMegIndex, sleY1731CcMacAddress, sleY1731CcMacControlRequest, sleY1731CcMacControlStatus, sleY1731CcMacControlTimer, sleY1731CcMacControlTimeStamp, sleY1731CcMacControlReqResult, sleY1731CcMacControlMegIndex, sleY1731CcMacControlMepIdentifier, sleY1731CcMacControlAddress, sleY1731AisMacAddress, sleY1731AisMacControlRequest, sleY1731AisMacControlStatus, sleY1731AisMacControlTimer, sleY1731AisMacControlTimeStamp, sleY1731AisMacControlReqResult, sleY1731AisMacControlMegIndex, sleY1731AisMacControlMepIdentifier, sleY1731AisMacControlAddress, sleY1731LckMacAddress, sleY1731LckMacControlRequest, sleY1731LckMacControlStatus, sleY1731LckMacControlTimer, sleY1731LckMacControlTimeStamp, sleY1731LckMacControlReqResult, sleY1731LckMacControlMegIndex, sleY1731LckMacControlMepIdentifier, sleY1731LckMacControlAddress, sleY1731RmepIdentifier, sleY1731RmepState, sleY1731RmepFailedOkTime, sleY1731RmepMacAddress, sleY1731RmepIfIndex, sleY1731RmepRdi, sleY1731RmepLoc, sleY1731RmepReceiveTstCount, sleY1731RmepReceiveTstOutOfOrder, sleY1731RmepReceiveTstBitError, sleY1731RmepReceiveTstCrcError, sleY1731RmepReceiveTmTstCount, sleY1731RmepReceiveTmTstLostId, sleY1731RmepLmrFrameLossNearMin, sleY1731RmepLmrFrameLossNearMax, sleY1731RmepLmrFrameLossNearSum, sleY1731RmepLmrFrameLossFarMin, sleY1731RmepLmrFrameLossFarMax, sleY1731RmepLmrFrameLossFarSum, sleY1731RmepReceive1dmCount, sleY1731Rmep1dmFrameDelayMin, sleY1731Rmep1dmFrameDelayMax, sleY1731Rmep1dmFrameDelayAvg, sleY1731Rmep1dmFrameDelayVar, sleY1731RmepReceiveDmrCount, sleY1731RmepDmrFrameDelayMin, sleY1731RmepDmrFrameDelayMax, sleY1731RmepDmrFrameDelayAvg, sleY1731RmepDmrFrameDelayVar, sleY1731LbrReceiveOrder, sleY1731LbrRemoteMacAddress, sleY1731LtrSeqNumber, sleY1731LtrReceiveOrder, sleY1731LtrForwarded, sleY1731LtrTerminalMep, sleY1731LtrLastEgressIdentifier, sleY1731LtrNextEgressIdentifier, sleY1731LtrRelay, sleY1731LtrIngress, sleY1731LtrIngressMac, sleY1731LtrIngressPort, sleY1731LtrEgress, sleY1731LtrEgressMac, sleY1731LtrEgressPort, sleY1731ConfigErrorVid, sleY1731ConfigErrorIfIndex, sleY1731ConfigErrorType, sleY1731MipCcdbIndex, sleY1731MipCcdbVlanId, sleY1731MipCcdbMacAddr, sleY1731MipCcdbPort, sleY1731MipCcdbKeepTime, sleY1731RmepCreation, sleY1731BaseControlRmepCreation, sleY1731BaseControlTrunkIndex, sleY1731BaseControlTrunkOamStatus, sleY1731TrunkIndex, sleY1731TrunkOamStatus, sleY1731BaseControlTrunkMeg, sleY1731TrunkMeg, sleY1731MepLbSuccessRate, sleY1731MepTmLbmCount, sleY1731MepTmLbrCount, sleY1731MepTmTstCount, sleY1731RmepControlRequest, sleY1731RMepControlStatus, sleY1731RmepControlTimer, sleY1731RmepControlTimeStamp, sleY1731RmepControlReqResult, sleY1731RmepControlIdentifier, sleY1731RmepControlMegIndex, sleY1731RmepControlIfIndex, sleY1731MegRapsEastPortStatus, sleY1731MegRapsWestPortStatus, sleY1731MegRapsNonRevertive, sleY1731MegRapsForcedSwitchEast, sleY1731MegRapsForcedSwitchWest, sleY1731MegControlRapsNonRevertive, sleY1731MegControlRapsForcedSwitchEast, sleY1731MegControlRapsForcedSwitchWest, sleY1731URMegName, sleY1731URDedicatedVlan, sleY1731UREnableStatus, sleY1731URConnectivityCheckMeg, sleY1731URPrimaryMepId, sleY1731URSecondaryMepId, sleY1731URControlVlan, sleY1731URNodeConf, sleY1731URNodeConfPortNum, sleY1731URNonRevertive, sleY1731URTrustMemberCount, sleY1731URWaitToRestore, sleY1731URControlRequest, sleY1731URControlStatus, sleY1731URControlTimer, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegName, sleY1731URControlDedicatedVlan, sleY1731URControlEnableStatus, sleY1731URControlConnectivityCheckMeg, sleY1731URControlPrimaryMepId, sleY1731URControlSecondaryMepId, sleY1731URControlControlVlan, sleY1731URControlNodeConf, sleY1731URControlNodeConfPortNum, sleY1731URControlNonRevertive, sleY1731URControlTrustMemberCount, sleY1731URControlWaitToRestore, sleY1731URMegIndex, sleY1731URControlMegIndex, sleY1731URNodeConfPortStatus, sleY1731CCIgnoreDefect, sleY1731RapsFloodingBlock, sleY1731BaseControlCCIgnoreDefect, sleY1731BaseControlRapsFloodingBlock, sleEMLogDisableStatus, sleEMLogAction, sleEMLogInterval, sleEMLogControlRequest, sleEMLogControlStatus, sleEMLogControlTimer, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlDisableStatus, sleEMLogControlAction, sleEMLogControlInterval, sleY1731MepLbRoundtripMin, sleY1731MepLbRoundtripMax, sleY1731MepLbRoundtripAvg, sleCfmEnable, sleCfmLtrCacheHoldTime, sleCfmLtrCacheSize, sleCfmSnmpServerTraps, sleCfmXcheckStartDelay, sleCfmBaseControlRequest, sleCfmBaseControlStatus, sleCfmBaseControlTimer, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult, sleCfmBaseControlEnable, sleCfmBaseControlLtrCacheHoldTime, sleCfmBaseControlLtrCacheSize, sleCfmBaseControlSnmpServerTraps, sleCfmBaseControlXcheckStartDelay, sleCfmBaseControlTrunkIndex, sleCfmBaseControlTrunkMdName, sleCfmBaseControlTrunkMaVid, sleCfmTrunkIndex, sleCfmTrunkMdName, sleCfmTrunkMaVid, sleCfmMdIndex, sleCfmMdName, sleCfmMdLevel, sleCfmMdMepEnable, sleCfmMdCcEnable, sleCfmMdCcInterval, sleCfmMdCcPriority, sleCfmMdCcLossThreshold, sleCfmMdCcHoldTime, sleCfmMdFaultPriority, sleCfmMdFaultKeepTime, sleCfmMdFaultClearTime, sleCfmMdXcheckEnable, sleCfmMdControlRequest, sleCfmMdControlStatus, sleCfmMdControlTimer, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex, sleCfmMdControlName, sleCfmMdControlLevel, sleCfmMdControlMepEnable, sleCfmMdControlCcEnable, sleCfmMdControlCcInterval, sleCfmMdControlCcPriority, sleCfmMdControlCcLossThreshold, sleCfmMdControlCcHoldTime, sleCfmMdControlFaultPriority, sleCfmMdControlFaultKeepTime, sleCfmMdControlFaultClearTime, sleCfmMdControlXcheckEnable, sleCfmMaIndex, sleCfmMaName, sleCfmMaVid, sleCfmMaMepEnable, sleCfmMaCcEnable, sleCfmMaCcInterval, sleCfmMaCcPriority, sleCfmMaCcLossThreshold, sleCfmMaCcFaultPriority, sleCfmMaCcFaultKeepTime, sleCfmMaCcFaultClearTime, sleCfmMaXcheckEnable, sleCfmMaControlRequest, sleCfmMaControlStatus, sleCfmMaControlTimer, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlIndex, sleCfmMaControlName, sleCfmMaControlVid, sleCfmMaControlMdIndex, sleCfmMaControlMepEnable, sleCfmMaControlCcEnable, sleCfmMaControlCcInterval, sleCfmMaControlCcPriority, sleCfmMaControlCcLossThreshold, sleCfmMaControlFaultPriority, sleCfmMaControlFaultKeepTime, sleCfmMaControlFaultClearTime, sleCfmMaControlXcheckEnable, sleCfmMepIdentifier, sleCfmMepIfIndex, sleCfmMepDirection, sleCfmMepEnable, sleCfmMepFngState, sleCfmMepCcEnable, sleCfmMepMacAddress, sleCfmMepCcPriority, sleCfmMepFaultPriority, sleCfmMepFaultKeepTime, sleCfmMepFaultClearTime, sleCfmMepHighestPrDefect, sleCfmMepDefects, sleCfmMepCciSentCcms, sleCfmMepNextLbmTransId, sleCfmMepLbrIn, sleCfmMepLbrInOutOfOrder, sleCfmMepLtmNextSeqNumber, sleCfmMepUnexpLtrIn, sleCfmMepControlRequest, sleCfmMepControlStatus, sleCfmMepControlTimer, sleCfmMepControlTimeStamp, sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex, sleCfmMepControlMaIndex, sleCfmMepControlIfIndex, sleCfmMepControlDirection, sleCfmMepControlEnable, sleCfmMepControlCcEnable, sleCfmMepControlCcPriority, sleCfmMepControlFaultPriority, sleCfmMepControlFaultKeepTime, sleCfmMepControlFaultClearTime, sleCfmMepControlTransmitLbmDestMacAddress, sleCfmMepControlTransmitLbmDestMepId, sleCfmMepControlTransmitLbmDestIsMepId, sleCfmMepControlTransmitLbmCount, sleCfmMepControlTransmitLbmInterval, sleCfmMepControlTransmitLbmTimeout, sleCfmMepControlTransmitLbmPriority, sleCfmMepControlTransmitLtmTargetMacAddress, sleCfmMepControlTransmitLtmTargetMepId, sleCfmMepControlTransmitLtmTargetIsMepId, sleCfmMepControlTransmitLtmFlags, sleCfmMepControlTransmitLtmTtl, sleCfmMipPort, sleCfmMipLevel, sleCfmMipType, sleCfmMipControlRequest, sleCfmMipControlStatus, sleCfmMipControlTimer, sleCfmMipControlTimeStamp, sleCfmMipControlReqResult, sleCfmMipControlPort, sleCfmMipControlLevel, sleCfmXcheckMepIdentifier, sleCfmXcheckMepState, sleCfmXcheckControlRequest, sleCfmXcheckControlStatus, sleCfmXcheckControlTimer, sleCfmXcheckControlTimeStamp, sleCfmXcheckControlReqResult, sleCfmXcheckControlMepIdentifier, sleCfmXcheckControlMdIndex, sleCfmXcheckControlMaIndex, sleCfmRmepIdentifier, sleCfmRmepState, sleCfmRmepMacAddress, sleCfmRmepIfIndex, sleCfmRmepRdi, sleCfmRmepPortStatus, sleCfmRmepInterfaceStatus, sleCfmLtrSeqNumber, sleCfmLtrReceiveOrder, sleCfmLtrTtl, sleCfmLtrForwarded, sleCfmLtrTerminalMep, sleCfmLtrLastEgressIdentifier, sleCfmLtrNextEgressIdentifier, sleCfmLtrRelay, sleCfmLtrIngress, sleCfmLtrIngressMac, sleCfmLtrIngressPort, sleCfmLtrEgress, sleCfmLtrEgressMac, sleCfmLtrEgressPort, sleCfmConfigErrorVid, sleCfmConfigErrorIfIndex, sleCfmConfigErrorType, sleCfmMipCcdbIndex, sleCfmMipCcdbVlanId, sleCfmMipCcdbMacAddr, sleCfmMipCcdbPort, sleCfmMipCcdbKeepTime, sleRapsRingId, sleRapsRingType, sleRapsRingLevel, sleRapsRingCtrlVlan, sleRapsRingTrafficVlans, sleRapsRingNodeId, sleRapsRingEnable, sleRapsRingBridgeRole, sleRapsRingState, sleRapsRingEastPort, sleRapsRingEastPortStatus, sleRapsRingWestPort, sleRapsRingWestPortStatus, sleRapsRingRplPort, sleRapsRingIcPort, sleRapsRingMultipleFailure, sleRapsRingPropagateTc, sleRapsRingNonRevertive, sleRapsRingForcedSwitch, sleRapsRingHoldOffTime, sleRapsRingGuardTime, sleRapsRingWaitToRestore, sleRapsRingWaitToBlock, sleRapsRingControlRequest, sleRapsRingControlStatus, sleRapsRingControlTimer, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlId, sleRapsRingControlType, sleRapsRingControlLevel, sleRapsRingControlCtrlVlan, sleRapsRingControlTrafficVlans, sleRapsRingControlEnable, sleRapsRingControlEastPort, sleRapsRingControlWestPort, sleRapsRingControlBridgeRole, sleRapsRingControlMultipleFailure, sleRapsRingControlPropagateTc, sleRapsRingControlNonRevertive, sleRapsRingControlHoldOffTime, sleRapsRingControlGuardTime, sleRapsRingControlWaitToRestore, sleRapsRingControlWaitToBlock, sleY1731LbrTransId, sleY1731LbrRoundTripTime, sleY1731TlvPermission, sleY1731BaseControlTlvPermission, sleY1731MepPmEnable, sleY1731MepCcmFrameLossNearRatio, sleY1731MepCcmFrameLossNearAvgRatio, sleY1731MepCcmFrameLossFarRatio, sleY1731MepCcmFrameLossFarAvgRatio, sleY1731MepControlPmEnable, sleY1731RmepLmrFrameLossNearRatio, sleY1731RmepLmrFrameLossNearAvgRatio, sleY1731RmepLmrFrameLossFarRatio, sleY1731RmepLmrFrameLossFarAvgRatio, sleY1731URSFCondition, sleY1731URControlSFCondition, sleAdvaOamControlMode, sleAlarmReportControlRequest, sleAlarmReportControlStatus, sleAlarmReportControlTimer, sleAlarmReportControlTimeStamp, sleAlarmReportControlReqResult, sleY1731URForceSwitch, sleY1731URControlForceSwitch, sleEMLogDefectCPUHigh, sleEMLogTemperHigh, sleEMLogTemperLow, sleEMLogMemLow, sleEMLogFanFail, sleEMLogPhyCRCFail, sleEMLogPhyDetectFail, sleEMLogSFUMateInitFail, sleEMLogDaemonHealthBad, sleY1731LtrTtl, sleY1731LRMepIndex, sleY1731LRMepDMegIndex, sleY1731LRMepDMepIdentifier, sleY1731LRMepDRmepIdentifier, sleY1731LRMepControlRequest, sleY1731LRMepControlStatus, sleY1731LRMepControlTimer, sleY1731LRMepControlTimeStamp, sleY1731LRMepControlReqResult, sleY1731LRMepControlMegIndex, sleY1731LRMepControlMepIdentifier, sleY1731LRMepControlRmepIdentifier, sleY1731LRMepControlDMegIndex, sleY1731LRMepControlDMepIdentifier, sleY1731LRMepControlDRmepIdentifier, sleEMLogGPIURavenLinkDown, sleY1731MepRllcfGuardTime, sleY1731MepControlRllcfGuardTime, sleOamRemLoopbackCnt, sleOamLm, sleOamLmAction, sleOamLmFrameWindow, sleOamLmFrameThresh, sleOamLmFrameTotal, sleOamLmFramePeriodWindow, sleOamLmFramePeriodThresh, sleOamLmFramePeriodTotal, sleOamLmFrameSecondSummaryWindow, sleOamLmFrameSecondSummaryThresh, sleOamLmFrameSecondSummaryTotal, sleOamLmSymbolPeriodWindow, sleOamLmSymbolPeriodThresh, sleOamLmSymbolPeriodTotal, sleOamLmRemSeqNum, sleOamLmRemFrameLength, sleOamLmRemFrameTimeStamp, sleOamLmRemFrameWindow, sleOamLmRemFrameThresh, sleOamLmRemFrameErrors, sleOamLmRemFrameErrorRunTotal, sleOamLmRemFrameEventRunTotal, sleOamLmRemFramePeriodLength, sleOamLmRemFramePeriodTimeStamp, sleOamLmRemFramePeriodWindow, sleOamLmRemFramePeriodThresh, sleOamLmRemFramePeriodErrors, sleOamLmRemFramePeriodErrorRunTotal, sleOamLmRemFramePeriodEventRunTotal, sleOamLmRemFrameSecondSummaryLength, sleOamLmRemFrameSecondSummaryTimeStamp, sleOamLmRemFrameSecondSummaryWindow, sleOamLmRemFrameSecondSummaryThresh, sleOamLmRemFrameSecondSummaryErrors, sleOamLmRemFrameSecondSummaryErrorRunTotal, sleOamLmRemFrameSecondSummaryEventRunTotal, sleOamLmRemSymbolPeriodLength, sleOamLmRemSymbolPeriodTimeStamp, sleOamLmRemSymbolPeriodWindow, sleOamLmRemSymbolPeriodThresh, sleOamLmRemSymbolPeriodErrors, sleOamLmRemSymbolPeriodErrorRunTotal, sleOamLmRemSymbolPeriodEventRunTotal, sleOamControlRemLoopbackPkCnt, sleOamControlLm, sleOamControlLmAction, sleOamControlLmFrameWindow, sleOamControlLmFrameThresh, sleOamControlLmFramePeriodWindow, sleOamControlLmFramePeriodThresh, sleOamControlLmFrameSecondSummaryWindow, sleOamControlLmFrameSecondSummaryThresh, sleOamControlLmSymbolPeriodWindow, sleOamControlLmSymbolPeriodThresh, sleY1731LtrRoundTripTime, sleY1731MepRllcf, sleY1731MepRllcfHoldOff, sleY1731MepControlRllcf, sleY1731MepControlRllcfHoldOff, sleRapsRingInstId, sleRapsRingChannel, sleRapsRingPassThrough, sleRapsRingManualSwitch, sleRapsRingVerifiedTime, sleRapsRingControlInstId, sleRapsRingVirtualVlan, sleRapsRingIcNode, sleY1731URTrafficVlan, sleY1731URState, sleY1731URControlTrafficVlan, sleAlarmReportPairType, sleAlarmHistoryPairType, sleY1731URManualSwitch, sleY1731URControlManualSwitch, sleEMLogNAKLockStatus, sleEMLogNakCompensate, sleEMLogRecoverActionMemLow, sleEMLogRecoverActionNak, sleEMLogControlNAKLockStatus, sleEMLogControlNAKCompensate, sleEMLogControlRecoverActionMemLow, sleEMLogControlRecoverActionNAK, sleEMLogNAK, sleFaultMonitorGlobalInspectInterval, sleFaultMonitorGlobalStartupThreshold, sleFaultMonitorGlobalNoKeepalive, sleFaultMonitorGlobalControlRequest, sleFaultMonitorGlobalControlStatus, sleFaultMonitorGlobalControlTimer, sleFaultMonitorGlobalControlTimeStamp, sleFaultMonitorGlobalControlReqResult, sleFaultMonitorGlobalControlInspectInterval, sleFaultMonitorGlobalControlStartupThreshold, sleFaultMonitorGlobalControlNoKeepalive, sleFaultMonitorDaemonName, sleFaultMonitorDaemonPid, sleFaultMonitorDaemonAdminStatus, sleFaultMonitorDaemonCrashAction, sleFaultMonitorDaemonTimeoutAction, sleFaultMonitorDaemonThreshold, sleFaultMonitorDaemonThresholded, sleFaultMonitorDaemonStartupThresholded, sleFaultMonitorDaemonWatchdogAdminStatus, sleFaultMonitorDaemonWatchdogThreshold, sleFaultMonitorDaemonWatchdogCount, sleFaultMonitorDaemonControlRequest, sleFaultMonitorDaemonControlStatus, sleFaultMonitorDaemonControlTimer, sleFaultMonitorDaemonControlTimeStamp, sleFaultMonitorDaemonControlReqResult, sleFaultMonitorDaemonControlAdminStatus, sleFaultMonitorDaemonControlCrashAction, sleFaultMonitorDaemonControlTimeoutAction, sleFaultMonitorDaemonControlThreshold, sleFaultMonitorDaemonControlWatchdogAdminStatus, sleFaultMonitorDaemonControlWatchdogThreshold, sleFaultMonitor2pointsLinearAdminStatus, sleFaultMonitor2pointsLinearInterval, sleFaultMonitor2pointsLinearThreshold, sleFaultMonitor2pointsLinearControlRequest, sleFaultMonitor2pointsLinearControlStatus, sleFaultMonitor2pointsLinearControlTimer, sleFaultMonitor2pointsLinearControlTimeStamp, sleFaultMonitor2pointsLinearControlReqResult, sleFaultMonitor2pointsLinearControlAdminStatus, sleFaultMonitor2PonitsLinearControlInterval, sleFaultMonitor2PointsLinearControlThreshold, sleFaultMonitorRHMAdminStatus, sleFaultMonitorRHMActionType, sleFaultMonitorRHMActionThreshold, sleFaultMonitorRHMRebootThreshold, sleFaultMonitorRHMRecoveryTime, sleFaultMonitorRHMFaultCounter, sleFaultMonitorRHMRebootCounter, sleFaultMonitorRHMHostAddr, sleFaultMonitorRHMControlRequest, sleFaultMonitorRHMControlStatus, sleFaultMonitorRHMControlTimer, sleFaultMonitorRHMControlTimeStamp, sleFaultMonitorRHMControlReqResult, sleFaultMonitorRHMControlAdminStatus, sleFaultMonitorRHMControlActionType, sleFaultMonitorRHMControlActionThreshold, sleFaultMonitorRHMControlRebootThreshold, sleFaultMonitorRHMControlRecoveryTime, sleFaultMonitorRHMControlHostAddr, sleEMLogFANRPMLow, sleFaultMonitorRHMInterval, sleFaultMonitorRHMLiveThreshold, sleFaultMonitorRHMControlInterval, sleFaultMonitorRHMControlLiveThreshold, sleY1731MegMd, sleY1731MegControlMd, sleFaultMonitorDaemonControlName, sleFaultMonitorDaemonControlThreshed, sleFaultMonitorDaemonControlStartupThresh, sleAlarmReportControlSpecificCode, sleAlarmReportControlSourceType, sleAlarmReportControlSource, sle2EthCfmEnable, sle2EthCfmLmmFrameCountSimStatus, sle2EthCfmControlRequest, sle2EthCfmControlStatus, sle2EthCfmControlTimer, sle2EthCfmControlTimeStamp, sle2EthCfmControlReqResult, sle2EthCfmControlEnable, sle2EthCfmControlLmmFrameCountSimStatus, sle2EthCfmBridgeId, sle2EthCfmBridgeDefaultMdLevel, sle2EthCfmBridgeDefaultMepId, sle2EthCfmBridgeAutomatic, sle2EthCfmBridgeConfigDefaultMdLevel, sle2EthCfmBridgeConfigDefaultMdMipCreation, sle2EthCfmBridgeLtrCacheEnable, sle2EthCfmBridgeLtrCacheSize, sle2EthCfmBridgeControlRequest, sle2EthCfmBridgeControlStatus, sle2EthCfmBridgeControlTimer, sle2EthCfmBridgeControlTimeStamp, sle2EthCfmBridgeControlReqResult, sle2EthCfmBridgeControlId, sle2EthCfmBridgeControlDefaultMdLevel, sle2EthCfmBridgeControlDefaultMepId, sle2EthCfmBridgeControlAutomatic, sle2EthCfmBridgeControlConfigDefaultMdLevel, sle2EthCfmBridgeControlConfigDefaultMdMipCreation, sle2EthCfmBridgeConntrolLtrCacheEnable, sle2EthCfmBridgeControlLtrCacheSize, sle2EthCfmVlanConfigPrimaryVid, sle2EthCfmVlanConfigSecondaryVid, sle2EthCfmVlanConfigSecondaryBridgeId, sle2EthCfmVlanConfigControlRequest, sle2EthCfmVlanConfigControlStatus, sle2EthCfmVlanConfigControlTimer, sle2EthCfmVlanConfigControlTimeStamp, sle2EthCfmVlanConfigControlReqResult, sle2EthCfmVlanConfigControlPrimaryBridgeId, sle2EthCfmVlanConfigControlPrimaryVid, sle2EthCfmVlanConfigControlSecondaryBridgeId, sle2EthCfmVlanConfigControlSecondaryVid, sle2EthCfmVlanInfoVid, sle2EthCfmVlanInfoPriority, sle2EthCfmVlanInfoControlRequest, sle2EthCfmVlanInfoControlStatus, sle2EthCfmVlanInfoControlTimer, sle2EthCfmVlanInfoControlTimeStamp, sle2EthCfmVlanInfoControlReqResult, sle2EthCfmVlanInfoControlBridgeId, sle2EthCfmVlanInfoControlVid, sle2EthCfmVlanInfoControlPriority, sle2EthCfmDefMdLevelEntryVid, sle2EthCfmDefMdLevelEntryLevel, sle2EthCfmDefMdLevelEntryMipCreation, sle2EthCfmDefMdLevelEntryControlRequest, sle2EthCfmDefMdLevelEntryControlStatus, sle2EthCfmDefMdLevelEntryControlTimer, sle2EthCfmDefMdLevelEntryControlTimeStamp, sle2EthCfmDefMdLevelEntryControlReqResult, sle2EthCfmDefMdLevelEntryControlBridgeId, sle2EthCfmDefMdLevelEntryControlVid, sle2EthCfmDefMdLevelEntryControlLevel, sle2EthCfmDefMdLevelEntryControlMipCreation, sle2EthCfmMdName, sle2EthCfmMdType, sle2EthCfmMdLevel, sle2EthCfmMdMipCreation, sle2EthCfmMdControlRequest, sle2EthCfmMdControlStatus, sle2EthCfmMdControlTimer, sle2EthCfmMdControlTimeStamp, sle2EthCfmMdControlReqResult, sle2EthCfmMdControlBridgeId, sle2EthCfmMdControlType, sle2EthCfmMdControlName, sle2EthCfmMdControlLevel, sle2EthCfmMdControlMipCreation, sle2EthCfmMaName, sle2EthCfmMaVid, sle2EthCfmMaType, sle2EthCfmMaMipCreation, sle2EthCfmMaCcInterval, sle2EthCfmMaElmi, sle2EthCfmMaConnectivityStatus, sle2EthCfmMaConfiguredRmepCount, sle2EthCfmMaConvergedRmepCount, sle2EthCfmMaControlRequest, sle2EthCfmMaControlStatus, sle2EthCfmMaControlTimer, sle2EthCfmMaControlTimeStamp, sle2EthCfmMaControlReqResult, sle2EthCfmMaControlBridgeId, sle2EthCfmMaControlMdName, sle2EthCfmMaControlName, sle2EthCfmMaControlType, sle2EthCfmMaControlVid, sle2EthCfmMaControlMipCreation, sle2EthCfmMaControlCcmInterval, sle2EthCfmMaControlElmi, sle2EthCfmMepInfoId, sle2EthCfmMepInfoIfindex, sle2EthCfmMepInfoLocalVid, sle2EthCfmMepInfoDirection, sle2EthCfmMepInfoActive, sle2EthCfmMepInfoUNI, sle2EthCfmMepInfoCcmStatus, sle2EthCfmMepInfoCcmType, sle2EthCfmMepInfoCcmRmepId, sle2EthCfmMepInfoLocalMacAddr, sle2EthCfmMepInfoRdi, sle2EthCfmMepInfoService, sle2EthCfmMepInfoLckLevel, sle2EthCfmMepInfoConnectivityStatus, sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlStatus, sle2EthCfmMepInfoControlTimer, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName, sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlIfindex, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlLocalVid, sle2EthCfmMepInfoControlMepDirection, sle2EthCfmMepInfoControlActive, sle2EthCfmMepInfoControlUNI, sle2EthCfmMepInfoControlCcmStatus, sle2EthCfmMepInfoControlFrameType, sle2EthCfmMepInfoControlRmepId, sle2EthCfmMepInfoControlService, sle2EthCfmMepInfoControlLckLevel, sle2EthCfmMepInfoControlTstPattern, sle2EthCfmMepInfoControlTstRecursive, sle2EthCfmMepInfoControlTstTxInterval, sle2EthCfmMepInfoControlTstLckInterval, sle2EthCfmMepInfoControlLckRmepId, sle2EthCfmMepAttrActive, sle2EthCfmMepAttrCcmLtmPriority, sle2EthCfmMepAttrLowPrDef, sle2EthCfmMepAttrFngAlarmTime, sle2EthCfmMepAttrResetFngTime, sle2EthCfmMepAttrCcmLtmFlag, sle2EthCfmMepAttrTxLtmTargetMac, sle2EthCfmMepAttrTxLtmTargetMepId, sle2EthCfmMepAttrTxLtmTargetIsMepId, sle2EthCfmMepAttrTxLtmTtl, sle2EthCfmMepAttrTxLtmEgressId, sle2EthCfmMepAttrTxLbmStatus, sle2EthCfmMepAttrTxLbmDestMac, sle2EthCfmMepAttrTxLbmDestMepId, sle2EthCfmMepAttrTxLbmDestIsMepId, sle2EthCfmMepAttrTxLbmMessages, sle2EthCfmMepAttrTxLbmDataTlv, sle2EthCfmMepAttrTxLbmVlanPriority, sle2EthCfmMepAttrTxLbmVlanDropEnable, sle2EthCfmMepAttrTxLbmTimeOut, sle2EthCfmMepAttrLbrTimeOut, sle2EthCfmMepAttrControlRequest, sle2EthCfmMepAttrControlStatus, sle2EthCfmMepAttrControlTimer, sle2EthCfmMepAttrControlTimeStamp, sle2EthCfmMepAttrControlReqResult, sle2EthCfmMepAttrControlBridgeId, sle2EthCfmMepAttrControlMdName, sle2EthCfmMepAttrControlMaVid, sle2EthCfmMepAttrControlMepId, sle2EthCfmMepAttrControlActive, sle2EthCfmMepAttrControlCcmLtmPriority, sle2EthCfmMepAttrContrlLowPrDef, sle2EthCfmMepAttrContrlFngAlarmTime, sle2EthCfmMepAttrControlResetFngTime, sle2EthCfmMepAttrControlCcmLtmFlag, sle2EthCfmMepAttrControlTxLtmTargetMac, sle2EthCfmMepAttrControlTxLtmTargetMepId, sle2EthCfmMepAttrControlTxLtmTargetIsMepId, sle2EthCfmMepAttrControlTxLtmTtl, sle2EthCfmMepAttrControlTxLtmEgressId, sle2EthCfmMepAttrControlTxLbmStatus, sle2EthCfmMepAttrControlTxLbmDestMacAddress, sle2EthCfmMepAttrControlTxLbmDestMepId, sle2EthCfmMepAttrControlTxLbmDestIsMepId, sle2EthCfmMepAttrControlTxLbmMessages, sle2EthCfmMepAttrControlTxLbmDataTlv, sle2EthCfmMepAttrControlTxLbmVlanPriority, sle2EthCfmMepAttrControlTxLbmVlanDropEnable, sle2EthCfmMepAttrControlTxLbmTimeOut, sle2EthCfmMepAttrControlLbrTimeOut, sle2EthCfmXcheckRmepId, sle2EthCfmXcheckRmepMac, sle2EthCfmXcheckControlRequest, sle2EthCfmXcheckControlStatus, sle2EthCfmXcheckControlTimer, sle2EthCfmXcheckControlTimeStamp, sle2EthCfmXcheckControlReqResult, sle2EthCfmXcheckControlBridgeId, sle2EthCfmXcheckControlMdName, sle2EthCfmXcheckControlMaVid, sle2EthCfmXcheckControlRmepId, sle2EthCfmXcheckControlRmepMac, sle2EthCfmLbReceivedCount, sle2EthCfmLbRemoteMacAddress, sle2EthCfmLbTxMessages, sle2EthCfmLbResponseCount, sle2EthCfmLbControlRequest, sle2EthCfmLbControlStatus, sle2EthCfmLbControlTimer, sle2EthCfmLbControlTimeStamp, sle2EthCfmLbControlReqResult, sle2EthCfmLbControlBridgeId, sle2EthCfmLbControlMdName, sle2EthCfmLbControlMaVid, sle2EthCfmLbControlMepId, sle2EthCfmLbControlMdLevel, sle2EthCfmLbControlRmepId, sle2EthCfmLbControlRmepMac, sle2EthCfmLbControlTlvData, sle2EthCfmLbControlTlvTest, sle2EthCfmLbControlRecursive, sle2EthCfmLtrMepMac, sle2EthCfmLtrHops, sle2EthCfmLtrRelay, sle2EthCfmLtrIngressEgress, sle2EthCfmLtrIngress, sle2EthCfmLtrEgress, sle2EthCfmLtControlRequest, sle2EthCfmLtControlStatus, sle2EthCfmLtControlTimer, sle2EthCfmLtControlTimeStamp, sle2EthCfmLtControlReqResult, sle2EthCfmLtControlBridgeId, sle2EthCfmLtControlMdName, sle2EthCfmLtControlMaVid, sle2EthCfmLtControlLevel, sle2EthCfmLtControlRmepMac, sle2EthCfmAisInfoStatus, sle2EthCfmAisInfoDefectConditions, sle2EthCfmAisInfoLevel, sle2EthCfmAisInfoFrameType, sle2EthCfmAisInfoRmepMac, sle2EthCfmAisInfoInterval, sle2EthCfmAisInfoReceivedDefectConditions, sle2EthCfmAisInfoLastReceivedDefectCondition, sle2EthCfmAisInfoControlRequest, sle2EthCfmAisInfoControlStatus, sle2EthCfmAisInfoControlTimer, sle2EthCfmAisInfoControlTimeStamp, sle2EthCfmAisInfoControlReqResult, sle2EthCfmAisInfoControlBridgeId, sle2EthCfmAisInfoControlMdName, sle2EthCfmAisInfoControlMaVid, sle2EthCfmAisInfoControlMepId, sle2EthCfmAisInfoControlEnable, sle2EthCfmAisInfoControlDefectConditions, sle2EthCfmAisInfoControlLevel, sle2EthCfmAisInfoControlFrameType, sle2EthCfmAisInfoControlRmepMac, sle2EthCfmAisInfoControlInterval, sle2EthCfmSrvAisIfIndex, sle2EthCfmSrvAisEnable, sle2EthCfmSrvAislevel, sle2EthCfmSrvAisInterval, sle2EthCfmSrvAisControlRequest, sle2EthCfmSrvAisControlStatus, sle2EthCfmSrvAisControlTimer, sle2EthCfmSrvAisControlTimeStamp, sle2EthCfmSrvAisControlReqResult, sle2EthCfmSrvAisControlBridgeId, sle2EthCfmSrvAisControlIfIndex, sle2EthCfmSrvAisControlEnable, sle2EthCfmSrvAisControlLevel, sle2EthCfmSrvAisControlInterval, sle2EthCfmLmmStatusRmepId, sle2EthCfmLmmStatusStartTime, sle2EthCfmLmmStatusCurrentTime, sle2EthCfmLmmStatusEndTime, sle2EthCfmLmmStatusNeerLoss, sle2EthCfmLmmStatusFarLoss, sle2EthCfmLmmStatusCurNeerLoss, sle2EthCfmLmmStatusCurFarLoss, sle2EthCfmRmepId, sle2EthCfmRempMepId, sle2EthCfmRmepLevel, sle2EthCfmRmepMaVid, sle2EthCfmRmepActiveState, sle2EthCfmRmepRemoteMac, sle2EthCfmRmepRdi, sle2EthCfmRmepFlags, sle2EthCfmRmepControlRequest, sle2EthCfmRmepControlStatus, sle2EthCfmRmepControlTimer, sle2EthCfmRmepControlTimeStamp, sle2EthCfmRmepControlReqResult, sle2EthCfmRmepControlBridgeId, sle2EthCfmRmepControlMdName, sle2EthCfmRmepControlMdLevel, sle2EthCfmMipVid, sle2EthCfmMipMdLevel, sle2EthCfmMipIfindex, sle2EthCfmMipLocalMac, sle2EthCfmStatCcmSent, sle2EthCfmStatCcmRevOutOfSeq, sle2EthCfmStatLbrSent, sle2EthCfmStatLbrRevValid, sle2EthCfmStatLbrRevBadMsdu, sle2EthCfmStatLbrRevOutOfSeq, sle2EthCfmStatLtrRevUnexpected, sle2EthCfmAcitveLevelIfIndex, sle2EthCfmActiveLevelStatus, sle2EthCfmErrorIndex, sle2EthCfmErrorMdLevel, sle2EthCfmErrorMaVid, sle2EthCfmErrorMepId, sle2EthCfmErrorRmepMac, sle2EthCfmErrorReason, sle2EthCfmErrorServiceId, sle2EthCfmErrorControlRequest, sle2EthCfmErrorControlStatus, sle2EthCfmErrorControlTimer, sle2EthCfmErrorControlTimeStamp, sle2EthCfmErrorControlReqResult, sle2EthCfmErrorControlBridgeId, sle2EthCfmErrorControlMdName, sle2EthCfmErrorControlMdLevel, sle2EthCfmLtCacheIndex, sle2EthCfmLtCacheSrcMac, sle2EthCfmLtCacheHops, sle2EthCfmLtCacheRelay, sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName, sle2ErpsPhyRingEastPort, sle2ErpsPhyRingWestPort, sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlStatus, sle2ErpsPhyRingControlTimer, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlBridgeId, sle2ErpsPhyRingControName, sle2ErpsPhyRingControEastPort, sle2ErpsPhyRingControWestPort, sle2ErpsProfileBridgeId, sle2ErpsProfileName, sle2ErpsProfileHoldOffTime, sle2ErpsProfileGuardTime, sle2ErpsProfileWaitToRestore, sle2ErpsProfileNonRevertive, sle2ErpsProfileControlRequest, sle2ErpsProfileControlStatus, sle2ErpsProfileControlTimer, sle2ErpsProfileControlTimeStamp, sle2ErpsProfileControlReqResult, sle2ErpsProfileControlBridgeId, sle2ErpsProfileControlName, sle2ErpsProfileControlHoldOffTime, sle2ErpsProfileControlGuardTime, sle2ErpsProfileControlWaitToRestore, sle2ErpsProfileControlNonRevertive, sle2ErpsInstBridgeId, sle2ErpsInstName, sle2ErpsInstPhyRingName, sle2ErpsInstProfileName, sle2ErpsInstRingId, sle2ErpsInstLevel, sle2ErpsInstRplRole, sle2ErpsInstRplRolePort, sle2ErpsInstSubRingBlock, sle2ErpsInstCtrlVlan, sle2ErpsInstTafficVlans, sle2ErpsInstVChannelVid, sle2ErpsInstVChannelAttachInstName, sle2ErpsInstPropagateTc, sle2ErpsInstStatus, sle2ErpsInstEastPortStatus, sle2ErpsInstWestPortStatus, sle2ErpsInstControlRequest, sle2ErpsInstControlStatus, sle2ErpsInstControlTimer, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlReqResult, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName, sle2ErpsInstControlPhyRingName, sle2ErpsInstControlProfileName, sle2ErpsInstControlRingId, sle2ErpsInstControlLevel, sle2ErpsInstControlRplRole, sle2ErpsInstControlRplRolePort, sle2ErpsInstControlSubRingBlock, sle2ErpsInstControlCtrlVlan, sle2ErpsInstControlTafficVlans, sle2ErpsInstControlVChannelVid, sle2ErpsInstControlVChannelAttachInstName, sle2ErpsInstControlForcedSwitch, sle2ErpsInstControlManualSwitch, sle2ErpsInstControlPropagateTc, sle2ErpsInstControlVersion, sleRapsRingControlIcNode, sleRapsRingControlChannel, sleRapsRingControlParamPort, sleRapsRingControlPassThrough, sleRapsRingControlVerifiedTime, sle2EthCfmMepInfoDlmState, sle2EthCfmMepInfoDlmRmepId, sle2EthCfmMepInfoControlDlmState, sle2EthCfmMepInfoControlDuration, sle2EthCfmMepInfoControlInterval, sle2EthCfmMepInfoControlTransMode, sle2EthCfmLbFrameType, sle2EthCfmLbControlTlvType, sle2ErpsPhyRingEastMepId, sle2ErpsPhyRingEastRmepId, sle2ErpsPhyRingWestMepId, sle2ErpsPhyRingWestRmepId, sle2ErpsPhyRingControlMepId, sle2ErpsPhyRingControlRmepId, sle2ErpsInstChannelMode, sle2ErpsInstActive, sle2ErpsInstEastIfindex, sle2ErpsInstWestIfindex, sle2EthCfmMepInfoInterval, sle2ErpsInstControlActive, sle2EthCfmLtControlMepId, sle2ErpsInstVersion, sle2ErpsInstDataTrafficInheritanceInstName, sle2ErpsInstControlDataTrafficInheritanceInstName } STATUS current DESCRIPTION "Description." ::= { sleFaultMgmt 19 } sleFaultMgmtNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { sleAlarmDefaultSeverityChanged, sleAlarmDefaultCriteriaChanged, sleNotificationActivityChanged, sleAlarmSeveriityCreated, sleAlarmSeveriityDestroyed, sleAlarmSeverityChanged, sleAlarmReportNotified, sleAlarmHistoryCleared, sleEfmOamPortProfileChanged, sleEfmOamPortRemLoopback, sleAdvaSystemProfileChanged, sleAdvaAlarmProfileChanged, sleAdvaElectricalInterfaceChanged, sleAdvaGeneralProfileChanged, sleAdvaAutonegProfileChanged, sleAdvaOpticalAlarmChanged, sleAlarmLEDOffChanged, sleAlarmLEDLevelChanged, sleAlarmLEDCleared, sleAlarmLEDBlockChanged, sleY1731EnableChanged, sleY1731TrunkEnableChanged, sleY1731LtrCacheProfileChanged, sleY1731SnmpProfileChanged, sleY1731XcheckProfileChanged, sleY1731DefaultMegProfileChanged, sleY1731PduToCfmChanged, sleY1731DedicatedVlanChanged, sleY1731MipCcdbDestroyed, sleY1731LtrCacheDestroyed, sleY1731MegCreated, sleY1731MegDeleted, sleY1731MegMepEnableChanged, sleY1731MegCcEnableChanged, sleY1731MegCcProfileChanged, sleY1731MegFaultProfileChanged, sleY1731MegXcheckEnableChanged, sleY1731MegAisEnableChanged, sleY1731MegAisTransmitEnableChanged, sleY1731MegAisProfileChanged, sleY1731MegLckEnableChanged, sleY1731MegLckTransmitEnableChanged, sleY1731MegLckProfileChanged, sleY1731MegOutOfServiceChanged, sleY1731MegRapsEnableChanged, sleY1731MegRapsRingportsChanged, sleY1731MegRapsRplPortChanged, sleY1731MegRapsRplOwnerChanged, sleY1731MegRapsTimerChanged, sleY1731MegRemoteMepDestroyed, sleY1731MegErrorDestroyed, sleY1731MepCreated, sleY1731MepDeleted, sleY1731MepEnableChanged, sleY1731MepCcEnableChanged, sleY1731MepFaultProfileChanged, sleY1731MepAisEnableChanged, sleY1731MepAisTransmitEnableChanged, sleY1731MepLckEnableChanged, sleY1731MepLckTransmitEnableChanged, sleY1731MepOutOfServiceChanged, sleY1731MepDlmEnableChanged, sleY1731MepTransmitLbmFinished, sleY1731MepTransmitLtmFinished, sleY1731MepTransmitTstLbmFinished, sleY1731MepTransmitTmLbmFinished, sleY1731MepTransmitTstFinished, sleY1731MepReceiveTstFinished, sleY1731MepTransmitTmTstFinished, sleY1731MepReceiveTmTstFinished, sleY1731MepTransmitLmmFinished, sleY1731MepTransmit1dmFinished, sleY1731MepReceive1dmFinished, sleY1731MepTransmitDmmFinished, sleY1731MipCreated, sleY1731MipDeleted, sleY1731XcheckMepCreated, sleY1731XcheckMepDeleted, sleY1731CcMacCreated, sleY1731CcMacDeleted, sleY1731AisMacCreated, sleY1731AisMacDeleted, sleY1731LckMacCreated, sleY1731LckMacDeleted, sleY1731RmepCreationChanged, sleY1731TrunkOamStatusChanged, sleY1731RmepCreated, sleY1731RmepDeleted, sleY1731MegRapsNonRevertiveChanged, sleY1731MegRapsForcedSwitchEastChanged, sleY1731MegRapsForcedSwitchWestChanged, sleY1731URDedicatedVlanChanged, sleY1731UREnableStatusChanged, sleY1731URCCPrimaryMepIdChanged, sleY1731URCCPrimaryMepIdCleared, sleY1731URCCSecondaryMepIdChanged, sleY1731URCCSecondaryMepIdCleared, sleY1731URControlVlanChanged, sleY1731URNodeConfChanged, sleY1731URNodeConfCleared, sleY1731URNonRevertiveChanged, sleY1731URTrustMemberCountChanged, sleY1731URTrustMemberCountCleared, sleY1731URWaitToRestoreChanged, sleY1731URWaitToRestoreCleared, sleY1731URControlVlanCleared, sleY1731URForceSwitchChanged, sleY1731URManualSwitchChanged, sleY1731CCIgnoreDefectChanged, sleY1731RapsFloodinBlockChanged, sleEMLogDisableStatusChanged, sleEMLogActionChanged, sleEMLogIntervalChanged, sleCfmEnableChanged, sleCfmLtrCacheProfileChanged, sleCfmSnmpServerTrapsChanged, sleCfmXcheckStartDelayChanged, sleCfmMipCcdbDestroyed, sleCfmLtrCacheDestroyed, sleCfmTrunkPortCreated, sleCfmTrunkPortDeleted, sleCfmMdCreated, sleCfmMdDeleted, sleCfmMdMepEnableChanged, sleCfmMdCcEnableChanged, sleCfmMdCcProfileChanged, sleCfmMdFaultProfileChanged, sleCfmMdXcheckEnableChanged, sleCfmMdErrorDestoryed, sleCfmMdRmepDestoryed, sleCfmMaCreated, sleCfmMaDeleted, sleCfmMaMepEnableChanged, sleCfmMaCcEnableChanged, sleCfmMaCcProfileChanged, sleCfmMaFaultProfileChanged, sleCfmMaXcheckEnableChanged, sleCfmMepCreated, sleCfmMepDeleted, sleCfmMepEnableChanged, sleCfmMepCcEnableChanged, sleCfmMepCcProfileChanged, sleCfmMepFaultProfileChanged, sleCfmMipCreated, sleCfmMipDeleted, sleCfmXcheckMepCreated, sleCfmXcheckMepDeleted, sleRapsRingCreated, sleRapsRingDeleted, sleRapsRingEnableChanged, sleRapsRingPortsCreated, sleRapsRingPortsDestroyed, sleRapsRingRplPortChanged, sleRapsRingMultipleFailureChanged, sleRapsRingPropagateTcChanged, sleRapsRingNonRevertiveChanged, sleRapsRingForcedSwitchChanged, sleRapsRingManualSwitchChanged, sleRapsRingSwitchCleared, sleRapsRingHoldOffTimeChanged, sleRapsRingGuardTimeChanged, sleRapsRingWtrTimeChanged, sleRapsRingWtbTimeChanged, sleY1731TlvPermissionChanged, sleY1731MepPmEnableChanged, sleY1731LRMepCreated, sleY1731LRMEPDeleted, setAdvaOamProfileChanged, sleAlarmReportCleared, sleEfmOamPortLinkMonitorChanged, sleRapsRingIcPortCreated, sleRapsRingIcPortDestroyed, sleY1731URTrafficVlanChanged, sleY1731URTrafficVlanCleared, sleEMLogNAKLockChanged, sleEMLogNAKCompensateChanged, sleEMLogRecoverActionMemLowChanged, sleEMLogRecoverActionNAKChanged, setFaultMonitorGlobalInspectIntervalChanged, setFaultMonitorGlobalStartupThresholdChanged, setFaultMonitorGlobalNoKeepaliveActionChanged, setFaultMonitorDaemonAdminStatusChanged, setFaultMonitorDaemonFaultActionChanged, setFaultMonitorDaemonThresholdChanged, setFaultMonitorDaemonWatchdogchanged, sleFaultMonitor2PointsLinearAdminStatusChanged, sleFaultMonitor2PointsLinearIntervalChanged, sleFaultMonitor2PointsLinearThresholdChanged, setRHMStatusChanged, setRHMActionThresholdChanged, setRHMRebootThresholdChanged, setRHMHostAdded, setRHMHostCleared, sleY1731MegMdAdded, sleY1731MegMdDeleted, sleAlarmReportDeleted, sle2EthCfmEnableChanged, sle2EthCfmLmmFrameCountSimulatorChanged, setCfmBridgeProfile, setCfmBridgeLtrCacheEnable, clearCfmBridgeLtrCache, setCfmBridgeAutomatic, setCfmBridgeConfigDefaultMdLevel, addCfmVlanConfVid, delCfmVlanConfVid, sle2EthCfmVlanPriorityChanged, sle2EthCfmDefMdLevelEntryChanged, sle2EthCfmDefMdLevelEntryCleared, sle2EthCfmMdCreated, sle2EthCfmMdDestoryed, sle2EthCfmMaCreated, sle2EthCfmMaDestoryed, sle2EthCfmCcIntervalChanged, sle2EthCfmElmiChanged, sle2EthCfmMepCreated, sle2EthCfmMepDestory, sle2EthCfmCcEnableChanged, sle2EthCfmServiceChanged, sle2EthCfmTransmitUnicastTstFinished, sle2EthCfmTransmitMulticastTstFinished, sle2EthCfmTransmitExmFinished, sle2EthCfmTransmitVsmFinished, sle2EthCfmTransmitMccFinished, sle2EthCfmMepFaultProfileChanged, sle2EthCfmMepTxLtmProfileChanged, sle2EthCfmMepTxLbmProfileChanged, sle2EthCfmMepAuttributesAllCleared, sle2EthCfmXcheckMepCreated, sle2EthCfmXcheckMepDestoryed, sle2EthCfmLbTransmitMulticastFinished, sle2EthCfmLbTransmitUnicastFinished, sle2EthCfmLbTransmitMacFinished, sle2EthCfmLbrFinished, sle2EthCfmLtTransmitDomainFinished, sle2EthCfmLtTransmitLevelFinished, sle2EthCfmLtrFinished, sle2EthCfmAisInfoStatusChanged, sle2EthCfmAisInfoIntervalChanged, sle2EthCfmSrvAisChanged, sle2EthCfmRmepDomainCleared, sle2EthCfmRmepLevelCleared, sle2EthCfmErrorDomainCleared, sle2EthCfmErrorLevelCleared, sle2ErpsPhyRingCreated, sle2ErpsPhyRingDestoryed, sle2ErpsPhyRingEastPortAdded, sle2ErpsPhyRingEastPortDeleted, sle2ErpsPhyRingWestPortAdded, sle2ErpsPhyRingWestPortDeleted, sle2ErpsProfileCreated, sle2ErpsProfileDestoryed, sle2ErpsProfileTimerChanged, sle2ErpsProfileNoneRevertiveChanged, sle2ErpsInstCreated, sle2ErpsInstDestoryed, sle2ErpsInstRingIdChanged, sle2ErpsInstLevelChanged, sle2ErpsInstRplRoleChanged, sle2ErpsInstSubRingAdded, sle2ErpsInstSubRingDeleted, sle2ErpsInstCtrlVlanAdded, sle2ErpsInstCtrlVlanDeleted, sle2ErpsInstDataTrafficVlanAdded, sle2ErpsInstDataTrafficVlanDeleted, sle2ErpsInstForcedSwichChanged, sle2ErpsInstManualSwichChanged, sle2ErpsInstClearChanged, sle2ErpsInstPropagateTcChanged, sle2ErpInstVersionChanged, sle2ErpInstDataTrafficInheritanceInstNameChanged, sle2ErpInstDataTrafficInheritanceInstNameDeleted, sleY1731URSFConditionChanged, sleY1731MepRllcfChanged, sleRapsRingChannelChanged, sleRapsRingPassThroughChanged, sleRapsRingVrfTimeChanged, sle2EthCfmDualEndLmmChanged, sle2EthCfmTransmitUnicastLmFinished, sle2EthCfmTransmitMulticastLmFinished, sle2EthCfmTransmitUnicastDmFinished, sle2EthCfmTransmitMuliticastDmFinished, sle2EthCfmReceive1DmFinished, sle2EthCfmTransmitTmFinished, sle2EthCfmReceiveTmFinished, sle2ErpsPhyRingEastMepIdAdded, sle2ErpsPhyRingEastMepIdDeleted, sle2ErpsPhyRingWestMepIdAdded, sle2ErpsPhyRingWestMepIdDeleted, sle2ErpsInstPhyRingAdded, sle2ErpsInstPhyRingDeleted, sle2ErpsInstProfileAdded, sle2ErpsInstProfileDeleted, sle2ErpsInstVitrualChannelAdded, sle2ErpsInstVitrualChannelDeleted, sle2ErpsInstNoneVirtualChannelAdded, sle2ErpsInstNoneVirtualChannelDeleted, sle2ErpInstActiveChanged } STATUS current DESCRIPTION "Description." ::= { sleFaultMgmt 20 } END -- -- sle-faultmgmt-mib.mib --