-- -- sle-mpls-tp-tunnel-mib.mib -- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88 -- Friday, January 15, 2016 at 13:52:12 -- SLE-MPLS-TP-TUNNEL-MIB DEFINITIONS ::= BEGIN IMPORTS sleMgmt FROM DASAN-SMI ifGeneralInformationGroup, ifCounterDiscontinuityGroup, InterfaceIndexOrZero FROM IF-MIB MplsCcId, MplsIccId FROM MPLS-TC-EXT-STD-MIB mplsStdMIB, MplsLabel FROM MPLS-TC-STD-MIB SleControlStatusType, SleControlRequestResultType FROM SLE-TC-MIB zeroDotZero, TimeTicks, IpAddress, Unsigned32, Gauge32, OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY FROM SNMPv2-SMI MacAddress FROM SNMPv2-TC; sleMplsTpTunnel MODULE-IDENTITY LAST-UPDATED "201510070000Z" -- October 07, 2015 at 00:00 GMT ORGANIZATION "Multiprotocol Label Switching (MPLS) Working Group" CONTACT-INFO "Gyerok Kwon Dasan Networks Email: grkwon@dasannetworks.com Kantharaj B M Dasan Networks Email: kanth@dasannetworks.com DongChel Shin (Chris) Dasan Networks Email: dchshin@dasannetworks.com Comments about this document should be emailed directly to the Dasan support email ID at support@dasannetworks.com." DESCRIPTION "Copyright (C) The Internet Society (2004). The initial version of this MIB module was published in RFC 3812. For full legal notices see the RFC itself or see: http://www.ietf.org/copyrights/ianamib.html This MIB module contains managed object definitions for MPLS Traffic Engineering (TE) as defined in: 1. Extensions to RSVP for LSP Tunnels, Awduche et al, RFC 3209, December 2001 2. Constraint-Based LSP Setup using LDP, Jamoussi (Editor), RFC 3212, January 2002 3. Requirements for Traffic Engineering Over MPLS, Awduche, D., Malcolm, J., Agogbua, J., O'Dell, M., and J. McManus, [RFC2702], September 1999" REVISION "200406030000Z" -- June 03, 2004 at 00:00 GMT DESCRIPTION "Initial version issued as part of RFC 3812." ::= { sleMpls 14 } -- -- Node definitions -- sleMpls OBJECT-IDENTITY STATUS current DESCRIPTION "SLE MPLS." ::= { sleMgmt 16 } sleMplsTpTunnelCfg OBJECT IDENTIFIER ::= { sleMplsTpTunnel 1 } sleMplsTpTunnelCfgInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF SleMplsTpTunnelCfgInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The mplsTunnelTable allows new MPLS tunnels to be created between an LSR and a remote endpoint, and existing tunnels to be reconfigured or removed. Note that only point-to-point tunnel segments are supported, although multipoint-to-point and point- to-multipoint connections are supported by an LSR acting as a cross-connect. Each MPLS tunnel can thus have one out-segment originating at this LSR and/or one in-segment terminating at this LSR." ::= { sleMplsTpTunnelCfg 1 } sleMplsTpTunnelCfgInfoEntry OBJECT-TYPE SYNTAX SleMplsTpTunnelCfgInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in this table represents an MPLS tunnel. An entry can be created by a network administrator or by an SNMP agent as instructed by an MPLS signalling protocol. Whenever a new entry is created with mplsTunnelIsIf set to true(1), then a corresponding entry is created in ifTable as well (see RFC 2863). The ifType of this entry is mplsTunnel(150). A tunnel entry needs to be uniquely identified across a MPLS network. Indices mplsTunnelIndex and mplsTunnelInstance uniquely identify a tunnel on the LSR originating the tunnel. To uniquely identify a tunnel across an MPLS network requires index mplsTunnelIngressLSRId. The last index mplsTunnelEgressLSRId is useful in identifying all instances of a tunnel that terminate on the same egress LSR." REFERENCE "1. RFC 2863 - The Interfaces Group MIB, McCloghrie, K., and F. Kastenholtz, June 2000 " INDEX { sleMplsTpTunnelCfgInfoIndex } ::= { sleMplsTpTunnelCfgInfoTable 1 } SleMplsTpTunnelCfgInfoEntry ::= SEQUENCE { sleMplsTpTunnelCfgInfoIndex Unsigned32, sleMplsTpTunnelCfgInfoName OCTET STRING, sleMplsTpTunnelCfgInfoId Unsigned32, sleMplsTpTunnelCfgInfoSrcIdType INTEGER, sleMplsTpTunnelCfgInfoSrcGId Unsigned32, sleMplsTpTunnelCfgInfoSrcCc MplsCcId, sleMplsTpTunnelCfgInfoSrcIcc MplsIccId, sleMplsTpTunnelCfgInfoSrcNodeId IpAddress, sleMplsTpTunnelCfgInfoDestIdType INTEGER, sleMplsTpTunnelCfgInfoDestGId Unsigned32, sleMplsTpTunnelCfgInfoDestCc MplsCcId, sleMplsTpTunnelCfgInfoDestIcc MplsIccId, sleMplsTpTunnelCfgInfoDestNodeId IpAddress, sleMplsTpTunnelCfgInfoMode INTEGER, sleMplsTpTunnelCfgInfoFwdInLabel MplsLabel, sleMplsTpTunnelCfgInfoFwdInIfIndex InterfaceIndexOrZero, sleMplsTpTunnelCfgInfoFwdOperation INTEGER, sleMplsTpTunnelCfgInfoFwdOutLabel MplsLabel, sleMplsTpTunnelCfgInfoFwdOutIfIndex InterfaceIndexOrZero, sleMplsTpTunnelCfgInfoFwdOutMac MacAddress, sleMplsTpTunnelCfgInfoRevInLabel MplsLabel, sleMplsTpTunnelCfgInfoRevInIfIndex InterfaceIndexOrZero, sleMplsTpTunnelCfgInfoRevOperation INTEGER, sleMplsTpTunnelCfgInfoRevOutLabel MplsLabel, sleMplsTpTunnelCfgInfoRevOutIfIndex InterfaceIndexOrZero, sleMplsTpTunnelCfgInfoRevOutMac MacAddress, sleMplsTpTunnelCfgInfoState INTEGER, sleMplsTpTunnelCfgInfoRole INTEGER, sleMplsTpTunnelCfgInfoAssociateTnlName OCTET STRING, sleMplsTpTunnelCfgInfoDescription OCTET STRING, sleMplsTpTunnelCfgInfoHlspRole INTEGER, sleMplsTpTunnelCfgInfoHlspServerTunnelName OCTET STRING, sleMplsTpTunnelCfgInfoQosPolicyName OCTET STRING } sleMplsTpTunnelCfgInfoIndex OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value which identify an entry in this table." ::= { sleMplsTpTunnelCfgInfoEntry 1 } sleMplsTpTunnelCfgInfoName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The canonical name assigned to the tunnel. This name can be used to refer to the tunnel on the LSR's console port. If mplsTunnelIsIf is set to true then the ifName of the interface corresponding to this tunnel should have a value equal to mplsTunnelName. Also see the description of ifName in RFC 2863." REFERENCE "RFC 2863 - The Interfaces Group MIB, McCloghrie, K., and F. Kastenholtz, June 2000." DEFVAL { "" } ::= { sleMplsTpTunnelCfgInfoEntry 2 } sleMplsTpTunnelCfgInfoId OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Uniquely identifies a set of tunnel instances between a pair of ingress and egress LSRs. Managers should obtain new values for row creation in this table by reading mplsTunnelIndexNext. When the MPLS signalling protocol is rsvp(2) this value SHOULD be equal to the value signaled in the Tunnel Id of the Session object. When the MPLS signalling protocol is crldp(3) this value SHOULD be equal to the value signaled in the LSP ID." ::= { sleMplsTpTunnelCfgInfoEntry 3 } sleMplsTpTunnelCfgInfoSrcIdType OBJECT-TYPE SYNTAX INTEGER { ietf(1), itut(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to set the ietf or itut type." ::= { sleMplsTpTunnelCfgInfoEntry 4 } sleMplsTpTunnelCfgInfoSrcGId OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "This Object is used to display the GlobalID of IETF" ::= { sleMplsTpTunnelCfgInfoEntry 5 } sleMplsTpTunnelCfgInfoSrcCc OBJECT-TYPE SYNTAX MplsCcId MAX-ACCESS read-only STATUS current DESCRIPTION "This Object is used to display the Source CC-ID of ITUT" ::= { sleMplsTpTunnelCfgInfoEntry 6 } sleMplsTpTunnelCfgInfoSrcIcc OBJECT-TYPE SYNTAX MplsIccId MAX-ACCESS read-only STATUS current DESCRIPTION "This Object is used to set the Source ICC-ID of ITUT" ::= { sleMplsTpTunnelCfgInfoEntry 7 } sleMplsTpTunnelCfgInfoSrcNodeId OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This Object is used to display the Source Node ID of IETF and ITUT" ::= { sleMplsTpTunnelCfgInfoEntry 8 } sleMplsTpTunnelCfgInfoDestIdType OBJECT-TYPE SYNTAX INTEGER { ietf(1), itut(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to set the ietf or itut type." ::= { sleMplsTpTunnelCfgInfoEntry 9 } sleMplsTpTunnelCfgInfoDestGId OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "This Object is used to set the Destination GlobalID of IETF" ::= { sleMplsTpTunnelCfgInfoEntry 10 } sleMplsTpTunnelCfgInfoDestCc OBJECT-TYPE SYNTAX MplsCcId MAX-ACCESS read-only STATUS current DESCRIPTION "This Object is used to display the Destination CC-ID of ITUT" ::= { sleMplsTpTunnelCfgInfoEntry 11 } sleMplsTpTunnelCfgInfoDestIcc OBJECT-TYPE SYNTAX MplsIccId MAX-ACCESS read-only STATUS current DESCRIPTION "This Object is used to set the Destination ICC-ID of ITUT" ::= { sleMplsTpTunnelCfgInfoEntry 12 } sleMplsTpTunnelCfgInfoDestNodeId OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This Object is used to display the Destination Node ID of IETF and ITUT" ::= { sleMplsTpTunnelCfgInfoEntry 13 } sleMplsTpTunnelCfgInfoMode OBJECT-TYPE SYNTAX INTEGER { none(0), unidirectional(1), bidirectional(2), corouted(3), associate(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to set the Tunnel Mode" ::= { sleMplsTpTunnelCfgInfoEntry 14 } sleMplsTpTunnelCfgInfoFwdInLabel OBJECT-TYPE SYNTAX MplsLabel MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to display the Forward In Label. The lable range is 0 to 1048575. Here 0 to 15 are reserved labels. User allowed range is 16 to 1048575.. The default value 1048576 is invalid label " DEFVAL { 1048576 } ::= { sleMplsTpTunnelCfgInfoEntry 15 } sleMplsTpTunnelCfgInfoFwdInIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to set the Forward IN Interface index " ::= { sleMplsTpTunnelCfgInfoEntry 16 } sleMplsTpTunnelCfgInfoFwdOperation OBJECT-TYPE SYNTAX INTEGER { none(0), push(1), pop(2), swap(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to set the Forward Ilm OPeration ." ::= { sleMplsTpTunnelCfgInfoEntry 17 } sleMplsTpTunnelCfgInfoFwdOutLabel OBJECT-TYPE SYNTAX MplsLabel MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to display the Forward In Label. The lable range is 0 to 1048575. Here 0 to 15 are reserved labels. User allowed range is 16 to 1048575. The default value 1048576 is invalid label " DEFVAL { 1048576 } ::= { sleMplsTpTunnelCfgInfoEntry 18 } sleMplsTpTunnelCfgInfoFwdOutIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to set the Forward OUT Interface index " ::= { sleMplsTpTunnelCfgInfoEntry 19 } sleMplsTpTunnelCfgInfoFwdOutMac OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to display the Forward OUT MAC ADDRESS " ::= { sleMplsTpTunnelCfgInfoEntry 20 } sleMplsTpTunnelCfgInfoRevInLabel OBJECT-TYPE SYNTAX MplsLabel MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to display the Forward In Label. The lable range is 0 to 1048575. Here 0 to 15 are reserved labels. User allowed range is 16 to 1048575. The default value 1048576 is invalid label " DEFVAL { 1048576 } ::= { sleMplsTpTunnelCfgInfoEntry 21 } sleMplsTpTunnelCfgInfoRevInIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to set the Reverse IN Interface index " ::= { sleMplsTpTunnelCfgInfoEntry 22 } sleMplsTpTunnelCfgInfoRevOperation OBJECT-TYPE SYNTAX INTEGER { none(0), push(1), pop(2), swap(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to set the Reverse Ilm OPeration ." ::= { sleMplsTpTunnelCfgInfoEntry 23 } sleMplsTpTunnelCfgInfoRevOutLabel OBJECT-TYPE SYNTAX MplsLabel MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to display the Forward In Label. The lable range is 0 to 1048575. Here 0 to 15 are reserved labels. User allowed range is 16 to 1048575. The default value 1048576 is invalid label " DEFVAL { 1048576 } ::= { sleMplsTpTunnelCfgInfoEntry 24 } sleMplsTpTunnelCfgInfoRevOutIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to set the Reverse OUT Interface index " ::= { sleMplsTpTunnelCfgInfoEntry 25 } sleMplsTpTunnelCfgInfoRevOutMac OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to display the Forward OUT MAC ADDRESS ." ::= { sleMplsTpTunnelCfgInfoEntry 26 } sleMplsTpTunnelCfgInfoState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is to display status of the tunnel." ::= { sleMplsTpTunnelCfgInfoEntry 27 } sleMplsTpTunnelCfgInfoRole OBJECT-TYPE SYNTAX INTEGER { source(0), transist(1), destination(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is to display Role of the tunnel." ::= { sleMplsTpTunnelCfgInfoEntry 28 } sleMplsTpTunnelCfgInfoAssociateTnlName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This object to display associate of reverse tunnel." ::= { sleMplsTpTunnelCfgInfoEntry 29 } sleMplsTpTunnelCfgInfoDescription OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { sleMplsTpTunnelCfgInfoEntry 30 } sleMplsTpTunnelCfgInfoHlspRole OBJECT-TYPE SYNTAX INTEGER { server(1), client(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to set the Hlsp Tunnel. whether the tunnel is Server or client. server (1) :- To set the Server Tunnel client(2) :- To set the Client Tunnel ." ::= { sleMplsTpTunnelCfgInfoEntry 31 } sleMplsTpTunnelCfgInfoHlspServerTunnelName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to set the server TunnelName, when sleMplsTpTunnelCfgControlHlspOption as a client ." ::= { sleMplsTpTunnelCfgInfoEntry 32 } sleMplsTpTunnelCfgInfoQosPolicyName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to set the Qos Policy name." ::= { sleMplsTpTunnelCfgInfoEntry 33 } sleMplsTpTunnelCfgControl OBJECT IDENTIFIER ::= { sleMplsTpTunnelCfg 2 } sleMplsTpTunnelCfgControlRequest OBJECT-TYPE SYNTAX INTEGER { createMplsTpTunnelEntry(1), deleteMplsTpTunnelEntry(2), setMplsTpTunnelMode(3), setNhlfe(4), setIlmPop(5), setIlmSwap(6), setAssociateTunnel(7), unsetNhlfe(8), unsetIlmPop(9), unsetIlmSwap(10), unsetAssociateTunnel(11), setDescription(12), setHlspServerLsp(13), setHlspClientLsp(14), unsetHlspServerLsp(15), unsetHlspClientLsp(16), setTunnelQosPolicyName(17), unsetTunnelQosPolicyName(18) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object holds the possible read-write columns that can be modified in the Tunnel table. For each read-write column of Tunnel table, a Set Operation controlvalue is added in this object." ::= { sleMplsTpTunnelCfgControl 1 } sleMplsTpTunnelCfgControlStatus OBJECT-TYPE SYNTAX SleControlStatusType MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the status of the configuration done." ::= { sleMplsTpTunnelCfgControl 2 } sleMplsTpTunnelCfgControlTimer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object is based on the SLE style where a timer is configured for every control table." ::= { sleMplsTpTunnelCfgControl 3 } sleMplsTpTunnelCfgControlTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the time at which the configuration is done." ::= { sleMplsTpTunnelCfgControl 4 } sleMplsTpTunnelCfgControlReqResult OBJECT-TYPE SYNTAX SleControlRequestResultType MAX-ACCESS read-only STATUS current DESCRIPTION "The standard result of the SET operation is stored here." ::= { sleMplsTpTunnelCfgControl 5 } sleMplsTpTunnelCfgControlName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "The canonical name assigned to the tunnel. This name can be used to refer to the tunnel on the LSR's console port. If mplsTunnelIsIf is set to true then the ifName of the interface corresponding to this tunnel should have a value equal to SlemplsTunnelName. Also see the description of ifName in RFC 2863." REFERENCE "RFC 2863 - The Interfaces Group MIB, McCloghrie, K., and F. Kastenholtz, June 2000." DEFVAL { "" } ::= { sleMplsTpTunnelCfgControl 6 } sleMplsTpTunnelCfgControlId OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the tunnel Id ." ::= { sleMplsTpTunnelCfgControl 7 } sleMplsTpTunnelCfgControlSrcIdType OBJECT-TYPE SYNTAX INTEGER { ietf(1), itut(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the ietf or itut type." ::= { sleMplsTpTunnelCfgControl 8 } sleMplsTpTunnelCfgControlSrcGId OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the source Global-Id for IETF ." ::= { sleMplsTpTunnelCfgControl 9 } sleMplsTpTunnelCfgControlSrcCc OBJECT-TYPE SYNTAX MplsCcId MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the source CC-ID for ITUT." ::= { sleMplsTpTunnelCfgControl 10 } sleMplsTpTunnelCfgControlSrcIcc OBJECT-TYPE SYNTAX MplsIccId MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the Source ICC-ID for ITUT." ::= { sleMplsTpTunnelCfgControl 11 } sleMplsTpTunnelCfgControlSrcNodeId OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the Source Node-Id for IETF and ITUT" ::= { sleMplsTpTunnelCfgControl 12 } sleMplsTpTunnelCfgControlDestIdType OBJECT-TYPE SYNTAX INTEGER { ietf(1), itut(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the ietf or itut type." ::= { sleMplsTpTunnelCfgControl 13 } sleMplsTpTunnelCfgControlDestGId OBJECT-TYPE SYNTAX Unsigned32 (1) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the Destination Global-Id for IETF ." ::= { sleMplsTpTunnelCfgControl 14 } sleMplsTpTunnelCfgControlDestCc OBJECT-TYPE SYNTAX MplsCcId MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the Destination CC-ID for ITUT." ::= { sleMplsTpTunnelCfgControl 15 } sleMplsTpTunnelCfgControlDestIcc OBJECT-TYPE SYNTAX MplsIccId MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the Destination ICC-ID for ITUT." ::= { sleMplsTpTunnelCfgControl 16 } sleMplsTpTunnelCfgControlDestNodeId OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the Destination NodeID for IETF and ITUT." ::= { sleMplsTpTunnelCfgControl 17 } sleMplsTpTunnelCfgControlMode OBJECT-TYPE SYNTAX INTEGER { unidirectional(1), bidirectional(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the Tunnel mode ." ::= { sleMplsTpTunnelCfgControl 18 } sleMplsTpTunnelCfgControlPath OBJECT-TYPE SYNTAX INTEGER { forwardPath(1), reversePath(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to Set the forward path and reverse path tunnel." ::= { sleMplsTpTunnelCfgControl 19 } sleMplsTpTunnelCfgControlInLabel OBJECT-TYPE SYNTAX MplsLabel MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the Inlabel. " ::= { sleMplsTpTunnelCfgControl 20 } sleMplsTpTunnelCfgControlInInterface OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the Ininterface index." ::= { sleMplsTpTunnelCfgControl 21 } sleMplsTpTunnelCfgControlOperation OBJECT-TYPE SYNTAX INTEGER { push(1), pop(2), swap(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the operation of Tuunel " ::= { sleMplsTpTunnelCfgControl 22 } sleMplsTpTunnelCfgControlOutLabel OBJECT-TYPE SYNTAX MplsLabel MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the outlabel. " ::= { sleMplsTpTunnelCfgControl 23 } sleMplsTpTunnelCfgControlOutInterface OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the outerinterface index." ::= { sleMplsTpTunnelCfgControl 24 } sleMplsTpTunnelCfgControlOutMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to Set the Out MacAddress ." ::= { sleMplsTpTunnelCfgControl 25 } sleMplsTpTunnelCfgControlAssociateTnlName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to Associated Forward tunnel and reverse tunnel with reverse tunnel name ." ::= { sleMplsTpTunnelCfgControl 26 } sleMplsTpTunnelCfgControlDescription OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { sleMplsTpTunnelCfgControl 27 } sleMplsTpTunnelCfgControlHlspSeverTunnelName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the server Tunnel name for associating server and client." ::= { sleMplsTpTunnelCfgControl 28 } sleMplsTpTunnelCfgControlQosPolicyName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to set the Qos Policy name." ::= { sleMplsTpTunnelCfgControl 29 } END -- -- sle-mpls-tp-tunnel-mib.mib --