IDKT-F2-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32 FROM SNMPv2-SMI OBJECT-GROUP FROM SNMPv2-CONF dkt FROM DKT-MIB MacAddress FROM SNMPv2-TC; f2MIB MODULE-IDENTITY LAST-UPDATED "201504210000Z" ORGANIZATION "DKT A/S" CONTACT-INFO "postal: DKT A/S Fanoevej 6 DK-4060 Kirke Saaby Denmark email: info@dktcomega.com" DESCRIPTION "DKT 797xx series MIB." ::= { dkt 15 } f2SwitchEngine OBJECT IDENTIFIER ::= { f2MIB 1 } f2IGMPSnooping OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Starts/stops IGMP snooping, input parameter 0 = stops IGMP snooping, 1 = starts IGMP snooping. Per Default IGMP snooping is disabled." ::= { f2SwitchEngine 1 } f2MTU OBJECT-TYPE SYNTAX INTEGER (0..8960) MAX-ACCESS read-write STATUS current DESCRIPTION "Set and get MTU. The following values are valid: 3072, 4096, 6144, 8960 (3k, 4k, 6k and 8960 bytes)" ::= { f2SwitchEngine 2 } f2FWDTable OBJECT-TYPE SYNTAX SEQUENCE OF F2FWDMacAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Get learned MAC addresses from LAN side of switch engine" ::= { f2SwitchEngine 3 } f2FWDMacAddressEntry OBJECT-TYPE SYNTAX F2FWDMacAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Learned MAC address from LAN side of switch engine" ::= { f2FWDTable 1 } F2FWDMacAddressEntry ::= SEQUENCE { F2FWDMacAddress OCTET STRING } F2FWDMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "MAC address from LAN" ::= { f2FWDMacAddressEntry 1 } f2Ports OBJECT IDENTIFIER ::= { f2MIB 2 } f2CPUPort OBJECT IDENTIFIER ::= { f2Ports 1 } f2CPUPortAutoNegotiation OBJECT-TYPE SYNTAX INTEGER (0..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays auto negotiation state for the port." ::= { f2CPUPort 1 } f2CPUPortSpeedMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the speed and duplex mode on the port." ::= { f2CPUPort 2 } f2CPUPortLinkStatus OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the Link status for the port" ::= { f2CPUPort 3 } f2CPUPortFlowControl OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control" ::= { f2CPUPort 4 } f2CPUPortEnable OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Status for CPU port. Always 1 for enabled." ::= { f2CPUPort 5 } f2WANPort OBJECT IDENTIFIER ::= { f2Ports 2 } f2WANPortAutoNegotiation OBJECT-TYPE SYNTAX INTEGER (0..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays auto negotiation state for the port." ::= { f2WANPort 1 } f2WANPortSpeedMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)" ::= { f2WANPort 2 } f2WANPortLinkStatus OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the Link status for the port" ::= { f2WANPort 3 } f2WANPortFlowControl OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control" ::= { f2WANPort 4 } f2WANPortEnable OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Status for WAN port. Always 1 for enabled." ::= { f2WANPort 5 } f2LAN1Port OBJECT IDENTIFIER ::= { f2Ports 3 } f2LAN1PortAutoNegotiation OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays auto negotiation state for the port." ::= { f2LAN1Port 1 } f2LAN1PortSpeedMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)" ::= { f2LAN1Port 2 } f2LAN1PortLinkStatus OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the Link status for the port" ::= { f2LAN1Port 3 } f2LAN1PortFlowControl OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control" ::= { f2LAN1Port 4 } f2LAN1PortEnable OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables LAN1 port. Set to 1 for Enabled set to 0 for Disabled." ::= { f2LAN1Port 5 } f2LAN2Port OBJECT IDENTIFIER ::= { f2Ports 4 } f2LAN2PortAutoNegotiation OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays auto negotiation state for the port." ::= { f2LAN2Port 1 } f2LAN2PortSpeedMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)" ::= { f2LAN2Port 2 } f2LAN2PortLinkStatus OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the Link status for the port" ::= { f2LAN2Port 3 } f2LAN2PortFlowControl OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control" ::= { f2LAN2Port 4 } f2LAN2PortEnable OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables LAN2 port. Set to 1 for Enabled set to 0 for Disabled." ::= { f2LAN2Port 5 } f2LAN3Port OBJECT IDENTIFIER ::= { f2Ports 5 } f2LAN3PortAutoNegotiation OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays auto negotiation state for the port." ::= { f2LAN3Port 1 } f2LAN3PortSpeedMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)" ::= { f2LAN3Port 2 } f2LAN3PortLinkStatus OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the Link status for the port" ::= { f2LAN3Port 3 } f2LAN3PortFlowControl OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control" ::= { f2LAN3Port 4 } f2LAN3PortEnable OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables LAN3 port. Set to 1 for Enabled set to 0 for Disabled." ::= { f2LAN3Port 5 } f2LAN4Port OBJECT IDENTIFIER ::= { f2Ports 6 } f2LAN4PortAutoNegotiation OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays auto negotiation state for the port." ::= { f2LAN4Port 1 } f2LAN4PortSpeedMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)" ::= { f2LAN4Port 2 } f2LAN4PortLinkStatus OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the Link status for the port" ::= { f2LAN4Port 3 } f2LAN4PortFlowControl OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control" ::= { f2LAN4Port 4 } f2LAN4PortEnable OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/Disables LAN4 port. Set to 1 for Enabled set to 0 for Disabled." ::= { f2LAN4Port 5 } f2ModuleGroup OBJECT-GROUP OBJECTS { f2SwitchEngine, f2IGMPSnooping, f2MTU, f2Ports, f2CPUPort, f2CPUPortAutoNegotiation, f2CPUPortSpeedMode, f2CPUPortLinkStatus, f2CPUPortFlowControl, f2CPUPortEnable, f2WANPort, f2WANPortAutoNegotiation, f2WANPortSpeedMode, f2WANPortLinkStatus, f2WANPortFlowControl, f2WANPortEnable, f2LAN1Port, f2LAN1PortAutoNegotiation, f2LAN1PortSpeedMode, f2LAN1PortLinkStatus, f2LAN1PortFlowControl, f2LAN1PortEnable, f2LAN2Port, f2LAN2PortAutoNegotiation, f2LAN2PortSpeedMode, f2LAN2PortLinkStatus, f2LAN2PortFlowControl, f2LAN2PortEnable, f2LAN3Port, f2LAN3PortAutoNegotiation, f2LAN3PortSpeedMode, f2LAN3PortLinkStatus, f2LAN3PortFlowControl, f2LAN3PortEnable, f2LAN4Port, f2LAN4PortAutoNegotiation, f2LAN4PortSpeedMode, f2LAN4PortLinkStatus, f2LAN4PortFlowControl, f2LAN4PortEnable } STATUS current DESCRIPTION "The objects are related to the DKT 797xx series module, MIB rev 09." ::= { f2MIB 3 } END