AGENT-GENERAL-MIB DEFINITIONS ::= BEGIN IMPORTS IpAddress, MODULE-IDENTITY, OBJECT-TYPE,Integer32 FROM SNMPv2-SMI TruthValue,RowStatus, MacAddress FROM SNMPv2-TC DisplayString FROM RFC1213-MIB InetAddressType, InetAddress FROM INET-ADDRESS-MIB AgentNotifyLevel,dlink-common-mgmt FROM DLINK-ID-REC-MIB VlanId FROM Q-BRIDGE-MIB; agentGeneralMgmt MODULE-IDENTITY LAST-UPDATED "201206260000Z" ORGANIZATION "D-Link Corp." CONTACT-INFO "http://support.dlink.com" DESCRIPTION "The structure of general management information for enterprise." ::= { dlink-common-mgmt 1 } -- ----------------------------------------------------------------------------- -- Textual Conventions -- ----------------------------------------------------------------------------- -- This definition may be excluded if IPv6 is not supported Ipv6Address ::= TEXTUAL-CONVENTION DISPLAY-HINT "2x:" STATUS current DESCRIPTION "This data type is used to model IPv6 addresses. This is a binary string of 16 octets in network byte-order." SYNTAX OCTET STRING (SIZE (16)) UnitList ::= OCTET STRING(SIZE (0..3)) -- ----------------------------------------------------------------------------- -- agentBasicInfo -- ----------------------------------------------------------------------------- agentBasicInfo OBJECT IDENTIFIER ::= { agentGeneralMgmt 1 } agentMgmtProtocolCapability OBJECT-TYPE SYNTAX INTEGER { other(1), snmp-ip(2), snmp-ipx(3), snmp-ip-ipx(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The network management protocol(s) supported by this agent." ::= { agentBasicInfo 1 } -- ----------------------------------------------------------------------------- -- agentMibcapabilityTable -- ----------------------------------------------------------------------------- agentMibCapabilityTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentMibCapabilityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of MIB capability entries supported by this agent." ::= { agentBasicInfo 2 } agentMibCapabilityEntry OBJECT-TYPE SYNTAX AgentMibCapabilityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A MIB capability entry containing objects that describe a particular MIB supported by this agent." INDEX { agentMibCapabilityIndex } ::= { agentMibCapabilityTable 1 } AgentMibCapabilityEntry ::= SEQUENCE { agentMibCapabilityIndex Integer32, agentMibCapabilityDescr DisplayString, agentMibCapabilityVersion Integer32, agentMibCapabilityType INTEGER } agentMibCapabilityIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A list of Agent MIB Capability Description entries." ::= { agentMibCapabilityEntry 1 } agentMibCapabilityDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..35)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the MIB supported by the agent." ::= { agentMibCapabilityEntry 2 } agentMibCapabilityVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The version of the MIB specified in this entry." ::= { agentMibCapabilityEntry 3 } agentMibCapabilityType OBJECT-TYPE SYNTAX INTEGER { other(1), standard(2), proprietary(3), experiment(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of MIB specified in this entry." ::= { agentMibCapabilityEntry 4 } agentStatusConsoleInUse OBJECT-TYPE SYNTAX INTEGER { other(1), in-use(2), not-in-use(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This indicates whether the console is currently in use." ::= { agentBasicInfo 3 } agentStatusSaveCfg OBJECT-TYPE SYNTAX INTEGER { other(1), proceeding(2), completed(3), failed(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This indicates the status of the device configuration. other (1) - This entry is currently in use but the conditions under which it will remain so are determined by each of the following values. proceeding (2) - The device configuration is currently being saved into NV-RAM. completed (3) - All of the device configuration parameters have been saved into NV-RAM. failed (4) - The process to save the device configuration has failed." ::= { agentBasicInfo 4 } agentStatusFileTransfer OBJECT-TYPE SYNTAX INTEGER { other(1) , in-process(2), invalid-file(3), violation(4), file-not-found(5), disk-full(6), complete(7), time-out(8), not-format(9), memory-full(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the firmware download control. If the value is stated as 'other', the firmware has not been updated since the device was started." ::= { agentBasicInfo 5 } -- ----------------------------------------------------------------------------- -- agentCPUutilizationTable -- ----------------------------------------------------------------------------- agentCPUutilization OBJECT IDENTIFIER ::= { agentBasicInfo 6 } agentCPUutilizationIn5sec OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time scale is set at 5 second intervals. The value will be between 0% (idle) and 100% (very busy)." ::= { agentCPUutilization 1 } agentCPUutilizationIn1min OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time scale is set at 1 minute intervals. The value will be between 0% (idle) and 100% (very busy)." ::= { agentCPUutilization 2 } agentCPUutilizationIn5min OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time scale is set at 5 minute intervals. The value will be between 0% (idle) and 100% (very busy)." ::= { agentCPUutilization 3 } agentDualImageStatus OBJECT-TYPE SYNTAX INTEGER { not-supported(0), supported(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The dual image status." ::= { agentBasicInfo 7 } -- ----------------------------------------------------------------------------- -- agentPORTutilizationTable -- ----------------------------------------------------------------------------- agentPORTutilizationTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentPORTutilizationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies the current utilization of a specified port." ::= { agentBasicInfo 8 } agentPORTutilizationEntry OBJECT-TYPE SYNTAX AgentPORTutilizationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of information regarding the port utilization function." INDEX { agentPORTutilizationProtIndex } ::= { agentPORTutilizationTable 1 } AgentPORTutilizationEntry ::= SEQUENCE { agentPORTutilizationProtIndex INTEGER, agentPORTutilizationTX INTEGER, agentPORTutilizationRX INTEGER, agentPORTutilizationUtil INTEGER, agentPORTutilizationRXUtil INTEGER, agentPORTutilizationTXUtil INTEGER } agentPORTutilizationProtIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the module's port number." ::= { agentPORTutilizationEntry 1 } agentPORTutilizationTX OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The current rate of transmitted frames on the specified port." ::= { agentPORTutilizationEntry 2 } agentPORTutilizationRX OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The current rate of received frames on the specified port." ::= { agentPORTutilizationEntry 3 } agentPORTutilizationUtil OBJECT-TYPE SYNTAX INTEGER (0..100) UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "The current percentages regarding port statistics." ::= { agentPORTutilizationEntry 4 } agentPORTutilizationRXUtil OBJECT-TYPE SYNTAX INTEGER (0..100) UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "The current percentages regarding port receive packets statistics." ::= { agentPORTutilizationEntry 5 } agentPORTutilizationTXUtil OBJECT-TYPE SYNTAX INTEGER (0..100) UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "The current percentages regarding port transmit packets statistics." ::= { agentPORTutilizationEntry 6 } -- ----------------------------------------------------------------------------- agentDRAMutilizationTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentDRAMutilizationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about DRAM memory." ::={agentBasicInfo 9} agentDRAMutilizationEntry OBJECT-TYPE SYNTAX AgentDRAMutilizationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of information about DRAM memory." INDEX {agentDRAMutilizationUnitID} ::={agentDRAMutilizationTable 1} AgentDRAMutilizationEntry ::= SEQUENCE { agentDRAMutilizationUnitID INTEGER, agentDRAMutilizationTotalDRAM INTEGER, agentDRAMutilizationUsedDRAM INTEGER, agentDRAMutilization INTEGER } agentDRAMutilizationUnitID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the unit ID. If the ID equals zero, it means the current device." ::={ agentDRAMutilizationEntry 1 } agentDRAMutilizationTotalDRAM OBJECT-TYPE SYNTAX INTEGER UNITS "KB" MAX-ACCESS read-only STATUS current DESCRIPTION "The size of total DRAM memory." ::={agentDRAMutilizationEntry 2} agentDRAMutilizationUsedDRAM OBJECT-TYPE SYNTAX INTEGER UNITS "KB" MAX-ACCESS read-only STATUS current DESCRIPTION "The size of used DRAM memory." ::={agentDRAMutilizationEntry 3} agentDRAMutilization OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The percentage of used DRAM memory of the total DRAM memory available. The value will be between 0% (idle) and 100% (very busy)." ::={agentDRAMutilizationEntry 4} -- ----------------------------------------------------------------------------- agentFLASHutilizationTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentFLASHutilizationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about the flash memory." ::={agentBasicInfo 10} agentFLASHutilizationEntry OBJECT-TYPE SYNTAX AgentFLASHutilizationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about the flash memory." INDEX {agentFLASHutilizationUnitID} ::={agentFLASHutilizationTable 1} AgentFLASHutilizationEntry ::= SEQUENCE { agentFLASHutilizationUnitID INTEGER, agentFLASHutilizationTotalFLASH INTEGER, agentFLASHutilizationUsedFLASH INTEGER, agentFLASHutilization INTEGER } agentFLASHutilizationUnitID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the unit ID. If the ID equals zero, it means the current device." ::={ agentFLASHutilizationEntry 1 } agentFLASHutilizationTotalFLASH OBJECT-TYPE SYNTAX INTEGER UNITS "KB" MAX-ACCESS read-only STATUS current DESCRIPTION "The total size of flash memory." ::={agentFLASHutilizationEntry 2} agentFLASHutilizationUsedFLASH OBJECT-TYPE SYNTAX INTEGER UNITS "KB" MAX-ACCESS read-only STATUS current DESCRIPTION "The size of the used flash memory." ::={agentFLASHutilizationEntry 3} agentFLASHutilization OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The percentage of used flash memory in total flash memory. The value will be between 0% (idle) and 100% (very busy)." ::={agentFLASHutilizationEntry 4} -- ----------------------------------------------------------------------------- agentStatusReset OBJECT-TYPE SYNTAX INTEGER { proceeding(1), completed(2), failed(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This indicates the status of 'agentReset'." ::= { agentBasicInfo 11 } agentSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A text string containing the serial number of this device." ::= { agentBasicInfo 12 } -- ----------------------------------------------------------------------------- agentFirmwareType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A text string containing the firmware type." ::= { agentBasicInfo 13 } -- ----------------------------------------------------------------------------- -- agentBasicConfig -- ----------------------------------------------------------------------------- agentBasicConfig OBJECT IDENTIFIER ::= { agentGeneralMgmt 2 } agentBscSwFileTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentBscSwFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of MIB Basic Config entry support files updated by this agent." ::= { agentBasicConfig 1 } agentBscSwFileEntry OBJECT-TYPE SYNTAX AgentBscSwFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A basic configuration entry containing the objects that describe a particular MIB supported by this agent." INDEX { agentBscSwFileIndex } ::= { agentBscSwFileTable 1 } AgentBscSwFileEntry ::= SEQUENCE { agentBscSwFileIndex Integer32, agentBscSwFileDscr DisplayString, agentBscSwFileAddr IpAddress, agentBscSwFileTransferType INTEGER, agentBscSwFile DisplayString, agentBscSwFileLocateId INTEGER, agentBscSwFileLoadType INTEGER, agentBscSwFileCtrl INTEGER, agentBscSwFileBIncrement TruthValue, agentBscSwFileCtrlID INTEGER, agentBscSwFileCtrlUnitID UnitList, agentBscSwFileIPv6Addr Ipv6Address, agentBscSwFileBootUpImage TruthValue, agentBscSwFileForceAgree TruthValue, agentBscSwFileInterfaceName DisplayString, agentBscSwFileServerDomainName DisplayString } agentBscSwFileIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The table index for the file entry" ::= { agentBscSwFileEntry 1 } agentBscSwFileDscr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The description of the software file purpose in this entry. Note: For systems that do not support a change to this object, setting a value for this object will cause the system to return bad-value error messages." ::= { agentBscSwFileEntry 2 } agentBscSwFileAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address where the file that needs to be downloaded is located, or the IP address where the file will be uploaded to." ::= { agentBscSwFileEntry 3 } agentBscSwFileTransferType OBJECT-TYPE SYNTAX INTEGER { other(1), network-load(2), out-of-band-load(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The channel through which the file will be downloaded or uploaded. Note: For systems that do not support all channels, setting a value to the unsupported channel will cause the system to return bad-value error messages." ::= { agentBscSwFileEntry 4 } agentBscSwFile OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the file to be downloaded from, or uploaded to, the TFTP server." ::= { agentBscSwFileEntry 5 } agentBscSwFileLocateId OBJECT-TYPE SYNTAX INTEGER (1..16) MAX-ACCESS read-write STATUS current DESCRIPTION "This object describes the type of file. runtime-code (1), log-file (2), cfg-file (3) Note: For systems that do not support changes to this object, setting a value for this object will cause the system to return bad-value error messages." ::= { agentBscSwFileEntry 6 } agentBscSwFileLoadType OBJECT-TYPE SYNTAX INTEGER { other(1), upload(2), download(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object provides the user with a choice of uploading or downloading the selected file. Note: For systems that do not support a change to this object, setting a value for this object will cause the system to return bad-value error messages." ::= { agentBscSwFileEntry 7 } agentBscSwFileCtrl OBJECT-TYPE SYNTAX INTEGER { other(1), inactive(2), start(3), delete(4), config-as-bootup(5), apply(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object gives the user the option of downloading runtime software. This setting will take effect when the system restarts. See Note (1) below Note: For systems that do not support changes to this object, setting a value to this object will cause the system to return bad-value error messages. start - Activate firmware. delete (4) - Delete the firmware by indicated firmware ID. config-as-bootup (5) - Configured as bootup firmware by the indicated firmware(ID). apply (6) - Apply the configuration to be the active configuration by the indicated config ID." ::= { agentBscSwFileEntry 8 } agentBscSwFileBIncrement OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the previous configuration will remain valid or not after downloading the configuration file. True: Keep valid False: Erase. " ::= { agentBscSwFileEntry 9 } agentBscSwFileCtrlID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The section ID of the firmware image or configuration file. A value of 0 indicates the boot-up firmware image or configuration file." ::= { agentBscSwFileEntry 10 } agentBscSwFileCtrlUnitID OBJECT-TYPE SYNTAX UnitList MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies which unit of the switch stack the firmware image will be downloaded from. One or more units can be set in this list. Each bit from the left to the right represents the switch from unit ID 1 to unit ID 12. A null entry in this field denotes all switches in the switch stack." ::= { agentBscSwFileEntry 11 } agentBscSwFileIPv6Addr OBJECT-TYPE SYNTAX Ipv6Address MAX-ACCESS read-write STATUS current DESCRIPTION "The IPv6 address where the file will be downloaded from or uploaded to." ::= { agentBscSwFileEntry 12 } agentBscSwFileBootUpImage OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "The result of the download will depend on whether the boot_up option is specified. Case 1: In the case where the master unit provides the file system and the slave unit does not provide the file system, when boot_up is specified, the file will be downloaded to the boot_up image on the slave. If boot_up is not specified, then the file will not be downloaded to this slave unit. Case 2: In the case where the master unit does not provide the file system and the slave unit provides the file system, when boot_up is specified, the file will be downloaded to the boot_up image on the slave unit. If boot_up is not specified, the file will not be downloaded to this slave unit. Case 3: In the case where the master unit and the slave unit both support or do not support the file system, the file will be downloaded to the specified file on the slave unit. If boot_up is specified, the downloaded file will be assigned as the boot_up image. True: boot_up option is specified. False: boot_up option is not specified. " ::= { agentBscSwFileEntry 13 } agentBscSwFileForceAgree OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "When the force_agree option is specified, the reboot command will be executed immediately, without any further confirmation from the user. True: force_agree option is specified. False: force_agree option is not specified. " ::= { agentBscSwFileEntry 14 } agentBscSwFileInterfaceName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "This node is used to specify the interface name when the agentBscSwFileIPv6Addr is the link local address." ::= { agentBscSwFileEntry 15 } agentBscSwFileServerDomainName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the domain name of the TFTP server." ::= { agentBscSwFileEntry 16 } agentFileTransfer OBJECT-TYPE SYNTAX INTEGER { other(1), start(2), start-and-reset(3), noaction(4) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "This object will execute the download or upload action. If start (2) is chosen, it will begin to download/upload and no reset will follow. If start-and-reset (3) is chosen, then the reset will be activated after completing the download or upload. No action if noaction (4) is chosen. Note: Because these functions will be limited by the support for the system in question, some of the selected items will be invalid. When the user selects an invalid entry, the system will respond with a bad-value status." ::= { agentBasicConfig 2 } agentSystemReset OBJECT-TYPE SYNTAX INTEGER { other(1), cold-start(2), warm-start(3), no-reset(4) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object indicates the agent system reset state. Setting this object to no-reset (4) has no effect. Setting this object to cold-start (2) or warm-start (3) will reset the agent. The agent always returns to no-reset (4) when this object is read. This object is replaced by 'agentReset'." ::= { agentBasicConfig 3 } agentRs232PortConfig OBJECT-TYPE SYNTAX INTEGER { other(1), console(2), out-of-band(3), notAvail(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the RS-232C mode once the device has restarted." ::= { agentBasicConfig 4 } agentOutOfBandBaudRateConfig OBJECT-TYPE SYNTAX INTEGER { other(1), baudRate-2400 (2), baudRate-9600 (3), baudRate-19200(4), baudRate-38400(5), baudRate-115200(6) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "This object allows the user to specify an out-of-band baud rate, which will take effect upon system restart. Note: Because these functions will be limited by the support for the system in question, some of the selected items will be invalid. When the user selects an invalid entry, the system will respond with a bad-value error message. " ::= { agentBasicConfig 5 } agentSaveCfg OBJECT-TYPE SYNTAX INTEGER { other(1), cfg-id1(2), cfg-id2(3), log(4), all(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the type of save command to be executed, when saving to NV-RAM. other (1) - None of the following. cfg-id1 (2) - Save configuration ID1. cfg-id2 (3)- Save configuration ID2. log (4) - Save log. all (5) - Save both (active configuration and log)." ::= { agentBasicConfig 6 } -- ----------------------------------------------------------------------------- -- swMultiImageInfoTable -- ----------------------------------------------------------------------------- swMultiImageInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF SwMultiImageInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { agentBasicConfig 7 } swMultiImageInfoEntry OBJECT-TYPE SYNTAX SwMultiImageInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of information about multiple image management." INDEX { swMultiImageInfoID } ::= { swMultiImageInfoTable 1 } SwMultiImageInfoEntry ::= SEQUENCE { swMultiImageInfoID INTEGER, swMultiImageVersion DisplayString, swMultiImageSize Integer32, swMultiImageUpdateTime DisplayString, swMultiImageFrom DisplayString, swMultiImageSendUser DisplayString, swMultiImageFileName DisplayString } swMultiImageInfoID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The stacking section ID of the firmware image. The stacking section ID = 256 * Unit ID + Image File ID." ::= { swMultiImageInfoEntry 1 } swMultiImageVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The recorded downloaded firmware version." ::= { swMultiImageInfoEntry 2 } swMultiImageSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The recorded downloaded firmware size." ::= { swMultiImageInfoEntry 3 } swMultiImageUpdateTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The recorded firmware update time." ::= { swMultiImageInfoEntry 4 } swMultiImageFrom OBJECT-TYPE SYNTAX DisplayString (SIZE (0..100)) MAX-ACCESS read-only STATUS current DESCRIPTION "The recorded IP address of the TFTP server" ::= { swMultiImageInfoEntry 5 } swMultiImageSendUser OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The record of the user who downloaded the firmware." ::= { swMultiImageInfoEntry 6 } swMultiImageFileName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "When the system is set to boot from SD card, this object will display the recorded path name of the boot firmware file. " ::= { swMultiImageInfoEntry 7 } -- ----------------------------------------------------------------------------- agentMultiCfgMgmt OBJECT IDENTIFIER ::= { agentBasicConfig 8 } swMultiCfgInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF SwMultiCfgInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { agentMultiCfgMgmt 1 } swMultiCfgInfoEntry OBJECT-TYPE SYNTAX SwMultiCfgInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of information about multiple configuration files." INDEX { swMultiCfgInfoID } ::= { swMultiCfgInfoTable 1 } SwMultiCfgInfoEntry ::= SEQUENCE { swMultiCfgInfoID INTEGER, swMultiCfgVersion DisplayString, swMultiCfgSize Integer32, swMultiCFgUpdateTime DisplayString, swMultiCfgFrom DisplayString, swMultiCfgSendUser DisplayString, swMultiCfgFileName DisplayString } swMultiCfgInfoID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The section ID of the configuration files." ::= { swMultiCfgInfoEntry 1 } swMultiCfgVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The recorded downloaded configuration version." ::= { swMultiCfgInfoEntry 2 } swMultiCfgSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The recorded downloaded configuration size (in bytes). " ::= { swMultiCfgInfoEntry 3 } swMultiCFgUpdateTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The recorded configuration update time displayed in string format, i.e. yyyy/mon/dd hh:mm:ss." ::= { swMultiCfgInfoEntry 4 } swMultiCfgFrom OBJECT-TYPE SYNTAX DisplayString (SIZE (0..100)) MAX-ACCESS read-only STATUS current DESCRIPTION "The recorded IP address of the TFTP server." ::= { swMultiCfgInfoEntry 5 } swMultiCfgSendUser OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The record of the user who downloaded the configuration file" ::= { swMultiCfgInfoEntry 6 } swMultiCfgFileName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "When the system is set to boot from SD card, this object displays the recorded path name of the boot configuration file. " ::= { swMultiCfgInfoEntry 7 } -- ----------------------------------------------------------------------------- swMultiCfgCurrentUsed OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The indicated configuration file ID of the system currently in use." ::= { agentMultiCfgMgmt 2 } swMultiCfgBootUp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the configuration file ID which will take effect upon the next reboot." ::= { agentMultiCfgMgmt 3 } -- ----------------------------------------------------------------------------- -- swMultiCfgCtrlTable -- ----------------------------------------------------------------------------- swMultiCfgCtrlTable OBJECT-TYPE SYNTAX SEQUENCE OF SwMultiCfgCtrlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { agentMultiCfgMgmt 4 } swMultiCfgCtrlEntry OBJECT-TYPE SYNTAX SwMultiCfgCtrlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of information about multiple configuration management." INDEX { swMultiCfgCtrlID } ::= { swMultiCfgCtrlTable 1 } SwMultiCfgCtrlEntry ::= SEQUENCE { swMultiCfgCtrlID INTEGER, swMultiCfgAction INTEGER } swMultiCfgCtrlID OBJECT-TYPE SYNTAX INTEGER{ cfgId-1(1), cfgId-2(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The section ID of the configuration file." ::= { swMultiCfgCtrlEntry 1 } swMultiCfgAction OBJECT-TYPE SYNTAX INTEGER { active(1), delete(2), apply(3), none(4), config-as-bootup-cfg(5) } MAX-ACCESS read-write STATUS current DESCRIPTION " save: Save configuration to active configuration ID when the parameter is omitted. active: Set any valid configuration as the active configuration. delete: Removes the configuration from the flash memory. This configuration cannot be the active or current configuration file. apply: Loads the indicated configuration file and applies it to the system. config-as-bootup-cfg: Configured as the boot-up configuration by the indicated configuration(ID)." ::= { swMultiCfgCtrlEntry 2 } -- ----------------------------------------------------------------------------- -- Add common severity control management -- ----------------------------------------------------------------------------- systemSeverityControlMgmt OBJECT IDENTIFIER ::= { agentBasicConfig 9 } systemSeverityTrapControl OBJECT-TYPE SYNTAX AgentNotifyLevel MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the level of trap severity control. The system has a severity level control and each trap should have a severity control set. When trap events occur and its severity is higher than the system severity control level, the trap works as defined. If the event severity is lower than the system severity control level, the event is ignored as if it did not occur." ::= { systemSeverityControlMgmt 1 } systemSeverityLogControl OBJECT-TYPE SYNTAX AgentNotifyLevel MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the level of trap severity control. The system has a severity level control and each trap should have a severity control set. When trap events occur and its severity is higher than the system severity control level, the trap works as defined. If the event severity is lower than the system severity control level, the event is ignored as if it did not occur." ::= { systemSeverityControlMgmt 2 } -- ----------------------------------------------------------------------------- -- agentTrustedHostMgmt -- ----------------------------------------------------------------------------- agentTrustedHostMgmt OBJECT IDENTIFIER ::= { agentBasicConfig 10 } agentTrustedHostTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentTrustedHostEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the trusted host information." ::= { agentTrustedHostMgmt 1 } agentTrustedHostEntry OBJECT-TYPE SYNTAX AgentTrustedHostEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of information about the trusted hosts." INDEX { agentTrustedHostIndex } ::= { agentTrustedHostTable 1 } AgentTrustedHostEntry ::= SEQUENCE { agentTrustedHostIndex INTEGER, agentTrustedHostIPAddress IpAddress, agentTrustedHostRowStatus RowStatus, agentTrustedHostIPSubnetMask IpAddress, agentTrustedHostForSNMP INTEGER, agentTrustedHostForTELNET INTEGER, agentTrustedHostForSSH INTEGER, agentTrustedHostForHTTP INTEGER, agentTrustedHostForHTTPS INTEGER, agentTrustedHostForPING INTEGER, agentTrustedHostAddrType InetAddressType, agentTrustedHostAddr InetAddress, agentTrustedHostIPv6PrefixLen INTEGER } agentTrustedHostIndex OBJECT-TYPE SYNTAX INTEGER (1..30) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the trusted host entry." ::= { agentTrustedHostEntry 1 } agentTrustedHostIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the IP address of the trusted host." ::= { agentTrustedHostEntry 2 } agentTrustedHostRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the status of this entry. When creating a trusted host entry, the IP address should also be set." ::= { agentTrustedHostEntry 3 } agentTrustedHostIPSubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the IP subnet mask of the trusted host." ::= { agentTrustedHostEntry 4 } agentTrustedHostForSNMP OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the trusted host for SNMP." ::= { agentTrustedHostEntry 5 } agentTrustedHostForTELNET OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the trusted host for Telnet." ::= { agentTrustedHostEntry 6 } agentTrustedHostForSSH OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the trusted host for SSH." ::= { agentTrustedHostEntry 7 } agentTrustedHostForHTTP OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the trusted host for HTTP." ::= { agentTrustedHostEntry 8 } agentTrustedHostForHTTPS OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the trusted host for HTTPS." ::= { agentTrustedHostEntry 9 } agentTrustedHostForPING OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the trusted host for PING." ::= { agentTrustedHostEntry 10 } agentTrustedHostAddrType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-create STATUS current DESCRIPTION "The type of trusted host address as specified by the 'agentTrustedHostAddr' object." ::= { agentTrustedHostEntry 11 } agentTrustedHostAddr OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the IP address of the trusted host." ::= { agentTrustedHostEntry 12 } agentTrustedHostIPv6PrefixLen OBJECT-TYPE SYNTAX INTEGER (1..128) MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the IPv6 prefix length of the IPv6 trusted host." ::= { agentTrustedHostEntry 13 } -- ----------------------------------------------------------------------------- -- agentTrustedHostDelAllState -- ----------------------------------------------------------------------------- agentTrustedHostDelAllState OBJECT-TYPE SYNTAX INTEGER{ none(1), start(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to delete all trusted host entries." ::= { agentTrustedHostMgmt 2 } -- ----------------------------------------------------------------------------- -- agentFDBMgmt -- ----------------------------------------------------------------------------- agentFDBMgmt OBJECT IDENTIFIER ::= { agentBasicConfig 11 } agentFDBClearAllState OBJECT-TYPE SYNTAX INTEGER{ other(1), start(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to clear all FDB entries." ::= { agentFDBMgmt 1 } agentFDBClearByPortTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentFDBClearByPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Used to clear FDB entries by port." ::= { agentFDBMgmt 2 } agentFDBClearByPortEntry OBJECT-TYPE SYNTAX AgentFDBClearByPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an entry of the agentFDBClearByPortTable." INDEX { agentFDBClearPortIndex } ::= { agentFDBClearByPortTable 1 } AgentFDBClearByPortEntry ::= SEQUENCE { agentFDBClearPortIndex INTEGER, agentFDBClearByPortAction INTEGER } agentFDBClearPortIndex OBJECT-TYPE SYNTAX INTEGER(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the port number." ::= { agentFDBClearByPortEntry 1 } agentFDBClearByPortAction OBJECT-TYPE SYNTAX INTEGER{ other(1), start(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether to clear FDB or not." ::= { agentFDBClearByPortEntry 2 } agentFDBClearByVlanTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentFDBClearByVlanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Used to clear FDB entries by port." ::= { agentFDBMgmt 3 } agentFDBClearByVlanEntry OBJECT-TYPE SYNTAX AgentFDBClearByVlanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an entry of agentFDBClearByPortTable." INDEX { agentFDBClearVid } ::= { agentFDBClearByVlanTable 1 } AgentFDBClearByVlanEntry ::= SEQUENCE { agentFDBClearVid VlanId, agentFDBClearByVlanAction INTEGER } agentFDBClearVid OBJECT-TYPE SYNTAX VlanId MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the VLAN-ID." ::= { agentFDBClearByVlanEntry 1 } agentFDBClearByVlanAction OBJECT-TYPE SYNTAX INTEGER{ other(1), start(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether to clear the FDB or not." ::= { agentFDBClearByVlanEntry 2 } agentFDBSecurityTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentFDBSecurityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Used to display the FDB entries that have been created by the security module." ::= { agentFDBMgmt 4} agentFDBSecurityEntry OBJECT-TYPE SYNTAX AgentFDBSecurityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an entry of agentFDBSecurityTable." INDEX { agentFDBVid, agentFDBMacAddress } ::= { agentFDBSecurityTable 1 } AgentFDBSecurityEntry ::= SEQUENCE { agentFDBVid VlanId, agentFDBMacAddress MacAddress, agentFDBPort INTEGER, agentFDBType INTEGER, agentFDBStatus INTEGER, agentFDBSecurityModule INTEGER } agentFDBVid OBJECT-TYPE SYNTAX VlanId MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the VLAN-ID." ::= { agentFDBSecurityEntry 1 } agentFDBMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the MAC address." ::= { agentFDBSecurityEntry 2 } agentFDBPort OBJECT-TYPE SYNTAX INTEGER(1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the port number." ::= { agentFDBSecurityEntry 3 } agentFDBType OBJECT-TYPE SYNTAX INTEGER{ dynamic(1), static(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the MAC address type." ::= { agentFDBSecurityEntry 4 } agentFDBStatus OBJECT-TYPE SYNTAX INTEGER{ drop(1), forward(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the MAC address's forwarding status." ::= { agentFDBSecurityEntry 5} agentFDBSecurityModule OBJECT-TYPE SYNTAX INTEGER{ dot1x(1), wac(2), jwac(3), port-security(4), mac-based-access-control(5), compound-authentication(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to indicate which security module created the current MAC address. dot1x: 802.1X. wac: Web-based Access Control. jwac: Web-Based Access Control extension for Japan. port-security: Port Security. mac-based-access-control: MAC-based Access Control. compound-authentication: Compound Authentication." ::= { agentFDBSecurityEntry 6} -- ----------------------------------------------------------------------------- -- agentARPMgmt -- ----------------------------------------------------------------------------- agentARPMgmt OBJECT IDENTIFIER ::= { agentBasicConfig 12 } agentARPClearAllState OBJECT-TYPE SYNTAX INTEGER{ other(1), start(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to clear all ARP entries." ::= { agentARPMgmt 1 } -- ----------------------------------------------------------------------------- -- agentGratuitousARPMgmt -- ----------------------------------------------------------------------------- agentGratuitousARPMgmt OBJECT IDENTIFIER ::={agentARPMgmt 2} agentGratuitousARPSendIpifStatusUpState OBJECT-TYPE SYNTAX INTEGER{ enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is used to enable/disable sending of gratuitous ARP request packets while the IPIF interface comes up. This is used to automatically announce the interface's IP address to other nodes. By default, the state is enabled, and only one ARP packet will be broadcast." DEFVAL { enabled } ::={ agentGratuitousARPMgmt 1} agentGratuitousARPSendDupIpDetectedState OBJECT-TYPE SYNTAX INTEGER{ enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is used to enable/disable the sending of gratuitous ARP request packets while a duplicate IP is detected. By default, the state is enabled. The duplicate IP detected state indicates that the system has received an ARP request packet that was sent by an IP address that matches the system's own IP address. In this case, the system knows that somebody out there is using an IP address that is in conflict with the system. In order to reclaim the correct host of this IP address, the system can send out the gratuitous ARP request packet for this duplicate IP address." DEFVAL { enabled } ::={ agentGratuitousARPMgmt 2} agentGratuitousARPLearningState OBJECT-TYPE SYNTAX INTEGER{ enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is used to enable/disable learning of an ARP entry in the ARP cache based on the received gratuitous ARP packet. If the switch receives a gratuitous ARP request/reply packet and the sender's IP address is in its ARP table, it should update the ARP entry. By default, the state is disabled." DEFVAL { disabled } ::={ agentGratuitousARPMgmt 3} agentGratuitousARPTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentGratuitousARPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Gratuitous ARP Table Information." ::={ agentGratuitousARPMgmt 4} agentGratuitousARPEntry OBJECT-TYPE SYNTAX AgentGratuitousARPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of information from the Gratuitous ARP Table." INDEX { agentGratuitousARPInterfaceName } ::={ agentGratuitousARPTable 1 } AgentGratuitousARPEntry ::= SEQUENCE { agentGratuitousARPInterfaceName DisplayString, agentGratuitousARPPeriodicalSendInterval INTEGER, agentGratuitousARPTrapState INTEGER, agentGratuitousARPLogState INTEGER } agentGratuitousARPInterfaceName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the IP interface." ::={agentGratuitousARPEntry 1} agentGratuitousARPPeriodicalSendInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is used to configure the interval for the periodic sending of gratuitous ARP request packets. 0 means do not send gratuitous ARP request packets periodically." DEFVAL { 0 } ::={agentGratuitousARPEntry 2} agentGratuitousARPTrapState OBJECT-TYPE SYNTAX INTEGER{ enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This indicates the state of the gratuitous ARP trap. The switch can trap the IP conflict events to inform the administrator. By default, the trap is disabled." DEFVAL { disabled } ::={agentGratuitousARPEntry 3} agentGratuitousARPLogState OBJECT-TYPE SYNTAX INTEGER{ enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This indicates the state of the gratuitous Log trap. The switch can log the IP conflict events to inform the administrator. By default, the event log is enabled." DEFVAL { enabled } ::={agentGratuitousARPEntry 4} agentARPTotalARPEntries OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Used to display the total number of ARP entries." ::= { agentARPMgmt 3 } agentARPRetryTimes OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "This indicates the retry times of the ARP request." ::= { agentARPMgmt 4 } -- ----------------------------------------------------------------------------- -- swMultiImageCtrlTable -- ----------------------------------------------------------------------------- swMultiImageCtrlTable OBJECT-TYPE SYNTAX SEQUENCE OF SwMultiImageCtrlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { agentBasicConfig 13 } swMultiImageCtrlEntry OBJECT-TYPE SYNTAX SwMultiImageCtrlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of information about multiple image management." INDEX { swMultiImageCtrlID } ::= { swMultiImageCtrlTable 1 } SwMultiImageCtrlEntry ::= SEQUENCE { swMultiImageCtrlID INTEGER, swMultiImageCtrlAction INTEGER } swMultiImageCtrlID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The stacking section ID of the firmware image. The stacking section ID = 256 * Unit ID + Image File ID." ::= { swMultiImageCtrlEntry 1 } swMultiImageCtrlAction OBJECT-TYPE SYNTAX INTEGER{ config-as-bootup-fw(1), delete(2), none(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the running status of the image which is specified by swMultiImageCtrlID and swMultiImageCtrlUnitID. config-as-bootup-fw (1) - Configured as the bootup firmware by the indicated firmware(ID). delete (2) - Delete the firmware by indicated firmware ID. none (3) - No action. " ::= { swMultiImageCtrlEntry 2 } -- ----------------------------------------------------------------------------- agentOutOfBandDataBits OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the out-of-band data bits." ::= { agentBasicConfig 14 } agentOutOfBandParityBits OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the out-of-band parity bits." ::= { agentBasicConfig 15 } agentOutOfBandStopBits OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the out-of-band stop bits." ::= { agentBasicConfig 16 } agentOutOfBandAutoLogoutConfig OBJECT-TYPE SYNTAX INTEGER { never(1), minutes-2(2), minutes-5(3), minutes-10(4), minutes-15(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object allows the user to specify an out-of-band auto logout time." ::= { agentBasicConfig 17 } -- ----------------------------------------------------------------------------- -- agentBscFileSystemMgmt -- ----------------------------------------------------------------------------- agentBscFileSystemMgmt OBJECT IDENTIFIER ::= { agentBasicConfig 18 } agentBscFileSystemTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentBscFileSystemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of MIB File System Basic Configuration entries supported by the file update of this agent." ::= { agentBscFileSystemMgmt 1 } agentBscFileSystemEntry OBJECT-TYPE SYNTAX AgentBscFileSystemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A File System basic configuration entry that contains objects describing a particular MIB supported by this agent." INDEX { agentBscFileSystemIndex } ::= { agentBscFileSystemTable 1 } AgentBscFileSystemEntry ::= SEQUENCE { agentBscFileSystemIndex Integer32, agentBscFileSystemDscr DisplayString, agentBscFileSystemServerAddr IpAddress, agentBscFileSystemServerIPv6Addr Ipv6Address, agentBscFileSystemServerFileName DisplayString, agentBscFileSystemDeviceDriverID INTEGER, agentBscFileSystemDeviceFileName DisplayString, agentBscFileSystemLoadType INTEGER, agentBscFileSystemCtrlUnitID UnitList, agentBscFileSystemBootUpImage TruthValue, agentBscFileSystemForceAgree TruthValue, agentBscFileSystemCtrl INTEGER, agentBscFileSystemInterfaceName DisplayString, agentBscFileSystemServerDomainName DisplayString, agentBscFileSystemIncrement TruthValue, agentBscFileSystemServerVrfName DisplayString } agentBscFileSystemIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The table index for the file entry. This object describes the file type. runtime-code (1), log-file (2), cfg-file (3), attack-log-file (7)" ::= { agentBscFileSystemEntry 1 } agentBscFileSystemDscr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The description of the software file purpose in this entry." ::= { agentBscFileSystemEntry 2 } agentBscFileSystemServerAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address where the file to be downloaded is located, or the IP address where the file will be uploaded to." ::= { agentBscFileSystemEntry 3 } agentBscFileSystemServerIPv6Addr OBJECT-TYPE SYNTAX Ipv6Address MAX-ACCESS read-write STATUS current DESCRIPTION "The IPv6 address where the file is to be downloaded from or uploaded to." ::= { agentBscFileSystemEntry 4 } agentBscFileSystemServerFileName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the file to be downloaded from or uploaded to the TFTP server. If agentBscFileSystemDeviceFileName is not set, the switch will default to using the bootup file as the runtime image for the switch." ::= { agentBscFileSystemEntry 5 } agentBscFileSystemDeviceDriverID OBJECT-TYPE SYNTAX INTEGER { none(1), a(2), b(3), c(4), d(5), e(6), f(7), g(8), h(9), i(10), j(11), k(12), l(13), m(14), n(15), o(16), p(17), q(18), r(19), s(20), t(21), u(22), v(23), w(24), x(25), y(26), z(27) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the drive of the device that the firmware to be uploaded/downloaded is located. If none (1) is specified, the switch will default to the current drive." ::= { agentBscFileSystemEntry 6 } agentBscFileSystemDeviceFileName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the file to be downloaded to the device, or uploaded from the device. When downloading or uploading, the agentBscFileSystemServerFileName object must also be set." ::= { agentBscFileSystemEntry 7 } agentBscFileSystemLoadType OBJECT-TYPE SYNTAX INTEGER { other(1), upload(2), download(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object allows the user to select a download or upload function for the file. Note: For systems that do not support changes to this object, setting a value for this object will cause the system to return a bad-value error message. " ::= { agentBscFileSystemEntry 8 } agentBscFileSystemCtrlUnitID OBJECT-TYPE SYNTAX UnitList MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies which unit of the switch stack the firmware image or configuration file should be downloaded from. One or more units can be set in this list. Each bit from left to right represents the switch from unit ID 1 to unit ID 12. If this list is set to null it represents all stack switches." ::= { agentBscFileSystemEntry 9 } agentBscFileSystemBootUpImage OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "The result of the download will depend on whether the boot_up option has been specified. Case 1: In the case of the master unit providing the file system and the slave unit not providing the file system, when the boot_up parameter is specified, then the file will be downloaded to the boot_up image on the slave. If the boot_up parameter is not specified, then the file will not be downloaded to this slave unit. Case 2: In the case of the master unit not providing the file system and the slave unit providing the file system, when the boot_up parameter is specified, then the file will be downloaded to the boot_up image on the slave unit. If boot_up is not specified, then the file will not be downloaded to this slave unit. Case 3: In the case of the master unit and the slave unit both supporting or not supporting the file system, the file will be downloaded to the specified file on the slave unit. If boot_up is specified, the downloaded file will be assigned as the boot_up image. True: boot_up option is specified. False: boot_up option is not specified.. " ::= { agentBscFileSystemEntry 10 } agentBscFileSystemForceAgree OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "When the force_agree option is specified, the reboot command will be executed immediately without any further confirmation from the user. True: force_agree option is specified. False: force_agree option is not specified.. " ::= { agentBscFileSystemEntry 11 } agentBscFileSystemCtrl OBJECT-TYPE SYNTAX INTEGER { other(1), inactive(2), start(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object allows the user to download runtime software. The settings will take effect when the system restarts. See Note (1) below Note 1: For systems which do not support value changes to this object, setting these values will cause the system to return a bad-value error message start (3) - activate firmware. " ::= { agentBscFileSystemEntry 12 } agentBscFileSystemInterfaceName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "This node is used to specify the interface name when agentBscFileSystemServerIPv6Addr is the local link address." ::= { agentBscFileSystemEntry 13 } agentBscFileSystemServerDomainName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the domain name of the TFTP server." ::= { agentBscFileSystemEntry 14 } agentBscFileSystemIncrement OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "If increment is specified, then the existing configuration will not be cleared before applying of the new configuration. If it is not specified, then the existing configuration will be cleared before applying of the new configuration. True : keep valid False : erase. " ::= { agentBscFileSystemEntry 15 } agentBscFileSystemServerVrfName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the VRF name of the TFTP server.Input string 'reserved' for the global space." ::= { agentBscFileSystemEntry 16} -- -------------------------------------------------------------------------------- agentBscFileSystemSaveConfigDriverID OBJECT-TYPE SYNTAX INTEGER { none(1), a(2), b(3), c(4), d(5), e(6), f(7), g(8), h(9), i(10), j(11), k(12), l(13), m(14), n(15), o(16), p(17), q(18), r(19), s(20), t(21), u(22), v(23), w(24), x(25), y(26), z(27) } MAX-ACCESS read-write STATUS current DESCRIPTION "The drive on the device that the configuration file is will be saved to. If none (1) is specified, the switch places the file on the current drive by default." ::= { agentBscFileSystemMgmt 2 } agentBscFileSystemSaveConfigFileName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the configuration file that will be saved to the device. When agentBscFileSystemSaveCfg is set to cfg (2), and if the agentBscFileSystemSaveConfigFileName is not null, the configuration file will be saved to the set file name. If set to null, the configuration file will be saved to the boot_up CFG file. " ::= { agentBscFileSystemMgmt 3 } agentBscFileSystemSaveCfg OBJECT-TYPE SYNTAX INTEGER { other(1), cfg(2), log(3), all(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This indicates the method of saving information to the NV-RAM of the device. other (1) - None of the following. cfg (2) - Save configuration. log (3) - Save log. all (4) - Save both ( active configuration and log)." ::= { agentBscFileSystemMgmt 4 } -- ----------------------------------------------------------------------------- agentFileSystemConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentFileSystemConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table indicates the information about the bootup files." ::= { agentBscFileSystemMgmt 5 } agentFileSystemConfigEntry OBJECT-TYPE SYNTAX AgentFileSystemConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of information about the bootup files for each unit of the switch stack." INDEX { agentFileSystemUnit } ::= { agentFileSystemConfigTable 1 } AgentFileSystemConfigEntry ::= SEQUENCE { agentFileSystemUnit Integer32, agentFileSystemDriverID INTEGER, agentFileSystemBootImage DisplayString, agentFileSystemBootConfig DisplayString, agentFileSystemActConfig DisplayString } agentFileSystemUnit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The unit ID." ::= { agentFileSystemConfigEntry 1 } agentFileSystemDriverID OBJECT-TYPE SYNTAX INTEGER { none(1), a(2), b(3), c(4), d(5), e(6), f(7), g(8), h(9), i(10), j(11), k(12), l(13), m(14), n(15), o(16), p(17), q(18), r(19), s(20), t(21), u(22), v(23), w(24), x(25), y(26), z(27) } MAX-ACCESS read-write STATUS current DESCRIPTION "The drive on the device that the configuration file will be saved to. If none (1) is specified, the switch will place the file to the current drive by default." ::= { agentFileSystemConfigEntry 2 } agentFileSystemBootImage OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "When displayed, it shows the current bootup image file name. When set, the set name will be set as the bootup image." ::= { agentFileSystemConfigEntry 3 } agentFileSystemBootConfig OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "When displayed, it shows the current bootup configuration file name. When set, the set name will be set as the bootup configuration." ::= { agentFileSystemConfigEntry 4 } agentFileSystemActConfig OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "When displayed, it shows null. When set, the set name will be active at once, but the set name will not be set as the bootup configuration." ::= { agentFileSystemConfigEntry 5 } -- ----------------------------------------------------------------------------- agentReboot OBJECT-TYPE SYNTAX INTEGER { none(1), start(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to restart the switch." ::= { agentBasicConfig 19 } agentReset OBJECT-TYPE SYNTAX INTEGER { none(1), config(2), system(3), reset(4), system-exclude-vlan(5), system-exclude-ip(6), system-exclude-vlan-ip(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to reset all switch parameters. none (1): No action. This is the default value of this object. config (2): All parameters are reset to default settings. The device will neither save nor reboot. system (3): All parameters are reset to default settings. The switch will then do a factory reset, save, and reboot. reset (4) : All parameters will be reset to default settings except for the IP address, user account, and history log. The device will neither save nor reboot. system-exclude-vlan(5) : All parameters are reset to default settings except for VLAN. The switch will then save its settings and reboot. system-exclude-ip(6) : All parameters are reset to default settings except IP address. The switch will then save its settings and reboot. system-exclude-vlan-ip(7): All parameters are reset to default settings except VLAN and IP address. The switch will then save its settings and reboot. " ::= { agentBasicConfig 20 } -- ----------------------------------------------------------------------------- -- agentFTPFileTable -- ----------------------------------------------------------------------------- agentFTPFileTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentFTPFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of the MIB Basic Config entries support files updated by this agent." ::= { agentBasicConfig 21 } agentFTPFileEntry OBJECT-TYPE SYNTAX AgentFTPFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A basic configuration entry containing the objects describing a particular MIB supported by this agent." INDEX { agentFTPFileIndex } ::= { agentFTPFileTable 1 } AgentFTPFileEntry ::= SEQUENCE { agentFTPFileIndex Integer32, agentFTPFileDscr DisplayString, agentFTPFileLoadType INTEGER, agentFTPFileAddr IpAddress, agentFTPTCPPort INTEGER, agentFTPFileName DisplayString, agentFTPUserName DisplayString, agentFTPPassword DisplayString, agentFTPFileCtrlID INTEGER, agentFTPFileBIncrement TruthValue, agentFTPFileCtrl INTEGER, agentFTPFileBootUpImage TruthValue, agentFTPFileForceAgree TruthValue, agentFTPFileIPv6Addr DisplayString, agentFTPFileInterfaceName DisplayString, agentFTPFileUnitID UnitList } agentFTPFileIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The table index for the file entry. This object describes the file type runtime-code (1), log-file (2), cfg-file (3)" ::= { agentFTPFileEntry 1 } agentFTPFileDscr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The description of the software file purpose in this entry. Note: For systems which do not support changes to this object, setting a value for this object will cause the system to return bad-value error messages." ::= { agentFTPFileEntry 2 } agentFTPFileLoadType OBJECT-TYPE SYNTAX INTEGER { other(1), upload(2), download(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object provides the user with a choice of uploading or downloading the selected file. Note: For systems which do not support a change of this object, setting a value to this object will cause the system to return bad-value error messages." ::= { agentFTPFileEntry 3 } agentFTPFileAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address that the file to be downloaded is located on, or the IP address where the file will be uploaded to." ::= { agentFTPFileEntry 4 } agentFTPTCPPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The TCP port number being used to establish the command connection." ::= { agentFTPFileEntry 5 } agentFTPFileName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the file to be downloaded from, or uploaded to, the FTP server." ::= { agentFTPFileEntry 6 } agentFTPUserName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is the user name to enter in upload/download. " ::= { agentFTPFileEntry 7 } agentFTPPassword OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is the password to enter for an upload/download." ::= { agentFTPFileEntry 8 } agentFTPFileCtrlID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The section ID of the firmware image or configuration file. A value of 0 indicates the boot-up firmware image or configuration file." ::= { agentFTPFileEntry 9 } agentFTPFileBIncrement OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the previous configuration will remain valid or not after downloading the configuration file. True: Keep valid False: Erase. " ::= { agentFTPFileEntry 10 } agentFTPFileCtrl OBJECT-TYPE SYNTAX INTEGER { other(1), start(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object gives the user the option to download runtime software. The setting will take effect when the system restarts. See Note (1) below Note 1: For systems which do not support changes to this object, setting a value for this object will cause the system to return bad-value error messages. " ::= { agentFTPFileEntry 11 } agentFTPFileBootUpImage OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether to set the special file as a boot up file or not. True: The boot-up option is specified. False: The boot-up option is not specified." ::= { agentFTPFileEntry 12 } agentFTPFileForceAgree OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "When the force-agree option is specified, the reboot command will be executed immediately without any further confirmation from the user. True: Force-agree option is specified. False: Force-agree option is not specified." ::= { agentFTPFileEntry 13 } agentFTPFileIPv6Addr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The IPv6 address where the file is to be downloaded from or uploaded to." ::= { agentFTPFileEntry 14 } agentFTPFileInterfaceName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This node is used to specify the interface name when agentFTPFileIPv6Addr is the local link address. " ::= { agentFTPFileEntry 15 } agentFTPFileUnitID OBJECT-TYPE SYNTAX UnitList MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies which unit of the switch stack the firmware image or configuration file should be downloaded from. One or more units can be set in this list. Each bit from left to right represents the switch from unit ID 1 to unit ID 12.If this list is set to null it represents all stack switches." ::= { agentFTPFileEntry 16 } -- ----------------------------------------------------------------------------- -- agentSnmpTrapState -- ----------------------------------------------------------------------------- agentSnmpTrapState OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if the SNMP trap is enabled or disabled." ::= { agentBasicConfig 22 } -- ----------------------------------------------------------------------------- -- agentOutOfBandMgmt -- ----------------------------------------------------------------------------- agentOutOfBandMgmt OBJECT IDENTIFIER ::= { agentBasicConfig 23 } agentOutOfBandMgmtState OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables or disables the interface." ::= { agentOutOfBandMgmt 1 } agentOutOfBandMgmtIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address for out of band management. This object can only take the value of the unicast IP address." ::= { agentOutOfBandMgmt 2 } agentOutOfBandMgmtSubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP net mask for out of band management." ::= { agentOutOfBandMgmt 3 } agentOutOfBandMgmtGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The gateway for out of band management. " ::= { agentOutOfBandMgmt 4 } agentOutOfBandMgmtLinkStatus OBJECT-TYPE SYNTAX INTEGER { link-up(1), link-down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current Link status for out of band management." ::= { agentOutOfBandMgmt 5 } -- ----------------------------------------------------------------------------- -- agentTrapMgmt -- ----------------------------------------------------------------------------- agentTrapMgmt OBJECT IDENTIFIER ::= { agentBasicConfig 24 } agentTrapColdStart OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "When enabled (1), whenever the device detects a cold start event, a trap will be sent out." ::= { agentTrapMgmt 1 } agentTrapWarmStart OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "When enabled (1), whenever the device detects a warm start event, a trap will be sent out." ::= { agentTrapMgmt 2 } agentTrapRmonRisingAlarm OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "When enabled (1), whenever the device detects a RMON rising alarm event , a trap will be sent out." ::= { agentTrapMgmt 3 } agentTrapRmonFallingAlarm OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "When enabled (1), whenever the device detects a RMON falling alarm event, a trap will be sent out." ::= { agentTrapMgmt 4 } agentTrapCfgSave OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "When enabled (1), whenever the device detects a configuration saving completed event, a trap will be sent out." ::= { agentTrapMgmt 5 } agentTrapCfgUpload OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "When enabled (1), whenever the device detects a configuration uploading completed event, a trap will be sent out." ::= { agentTrapMgmt 6 } agentTrapCfgDownload OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "When enabled (1), whenever the device detects a configuration downloading completed event, a trap will be sent out" ::= { agentTrapMgmt 7 } -- ----------------------------------------------------------------------------- -- agentFTPFileSystemTable -- ----------------------------------------------------------------------------- agentFTPFileSystemTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentFTPFileSystemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The FTP management table for the file system" ::= { agentBasicConfig 25 } agentFTPFileSystemEntry OBJECT-TYPE SYNTAX AgentFTPFileSystemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A File System basic configuration entry that contains objects describing a particular MIB supported by this agent." INDEX { agentFTPFileSystemIndex } ::= { agentFTPFileSystemTable 1 } AgentFTPFileSystemEntry ::= SEQUENCE { agentFTPFileSystemIndex Integer32, agentFTPFileSystemDscr DisplayString, agentFTPFileSystemLoadType INTEGER, agentFTPFileSystemAddressType InetAddressType, agentFTPFileSystemAddress InetAddress, agentFTPFileSystemTCPPort INTEGER, agentFTPFileSystemServerFileName DisplayString, agentFTPFileSystemDeviceFileName DisplayString, agentFTPFileSystemUserName DisplayString, agentFTPFileSystemPassword DisplayString, agentFTPFileSystemCtrlUnitID UnitList, agentFTPFileSystemBootUpImage TruthValue, agentFTPFileSystemCtrl INTEGER, agentFTPFileSystemVrfName DisplayString } agentFTPFileSystemIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table index for the file entry." ::= { agentFTPFileSystemEntry 1 } agentFTPFileSystemDscr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The description of the software file purpose in this entry." ::= { agentFTPFileSystemEntry 2 } agentFTPFileSystemLoadType OBJECT-TYPE SYNTAX INTEGER { other(1), upload(2), download(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object allows the user to select a download or upload function for the file." ::= { agentFTPFileSystemEntry 3 } agentFTPFileSystemAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-write STATUS current DESCRIPTION "The address type of agentFTPFileSystemAddress." ::= { agentFTPFileSystemEntry 4 } agentFTPFileSystemAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the FTP server address." ::= {agentFTPFileSystemEntry 5} agentFTPFileSystemTCPPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The TCP port number being used to establish the control connection." ::= { agentFTPFileSystemEntry 6 } agentFTPFileSystemServerFileName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the file to be downloaded from or uploaded to the FTP server." ::= { agentFTPFileSystemEntry 7 } agentFTPFileSystemDeviceFileName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the file to be downloaded to the device, or uploaded from the device. If agentFTPFileSystemDeviceFileName is not set, the switch will default to the bootup file." ::= { agentFTPFileSystemEntry 8 } agentFTPFileSystemUserName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the user name to access the FTP server." ::= { agentFTPFileSystemEntry 9 } agentFTPFileSystemPassword OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the password to access the FTP server." ::= { agentFTPFileSystemEntry 10 } agentFTPFileSystemCtrlUnitID OBJECT-TYPE SYNTAX UnitList MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies which unit of the switch stack the firmware image or configuration file should be downloaded from. One or more units can be set in this list. Each bit from left to right represents the switch from unit ID 1 to unit ID 12.If this list is set to null it represents all stack switches." ::= { agentFTPFileSystemEntry 11 } agentFTPFileSystemBootUpImage OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether to set the special file as the boot up file or not. True: The boot-up option is specified. False: The boot-up option is not specified." ::= { agentFTPFileSystemEntry 12 } agentFTPFileSystemCtrl OBJECT-TYPE SYNTAX INTEGER { other(1), start(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object allows the user to execute an FTP download/upload." ::= { agentFTPFileSystemEntry 13 } agentFTPFileSystemVrfName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the VRF name of the FTP server.Input string 'reserved' for the global space." ::= { agentFTPFileSystemEntry 14 } -- ----------------------------------------------------------------------------- -- agentBscCMDLogState -- ----------------------------------------------------------------------------- agentBscCMDLogState OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the command logging state." ::= { agentBasicConfig 26 } -- ----------------------------------------------------------------------------- -- agentBscBroadcastPingReplyState -- ----------------------------------------------------------------------------- agentBscBroadcastPingReplyState OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the broadcast ping reply state." ::= { agentBasicConfig 27 } -- ----------------------------------------------------------------------------- -- agentBscTftpConfigMgmt -- ----------------------------------------------------------------------------- agentBscTftpConfigMgmt OBJECT IDENTIFIER ::= { agentBasicConfig 28 } agentBscTftpCfgFirmwareFile OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The firmware pathname that needs to be downloaded/uploaded from/to the TFTP server." ::= { agentBscTftpConfigMgmt 1 } agentBscTftpCfgConfigFile OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The configuration pathname that needs to be downloaded/uploaded from/to the TFTP server." ::= { agentBscTftpConfigMgmt 2 } agentBscTftpCfgLogFile OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The log pathname that needs to be uploaded to the TFTP server." ::= { agentBscTftpConfigMgmt 3 } agentBscTftpCfgAttackLogFile OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The attack log pathname that needs to be uploaded to the TFTP server." ::= { agentBscTftpConfigMgmt 4 } agentBscTftpCfgCertificateFile OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The certificate pathname that needs to be downloaded from the TFTP server." ::= { agentBscTftpConfigMgmt 5 } agentBscTftpCfgKeyFile OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The key pathname that needs to be downloaded from the TFTP server." ::= { agentBscTftpConfigMgmt 6 } agentBscTftpCfgTechSuooprtFile OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The technique's support information pathname that needs to be uploaded to the TFTP server." ::= { agentBscTftpConfigMgmt 7 } agentBscTftpCfgDebugLogFile OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The debug log pathname that needs to be uploaded to the TFTP server." ::= { agentBscTftpConfigMgmt 8 } agentBscTftpCfgSIMFirmwareFile OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The firmware pathname that needs to be downloaded/uploaded from/to the TFTP server when it is SIM enabled." ::= { agentBscTftpConfigMgmt 9 } agentBscTftpCfgSIMConfigFile OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The configuration pathname that needs to be downloaded/uploaded from/to the TFTP server when it is SIM enabled." ::= { agentBscTftpConfigMgmt 10 } agentBscTftpCfgSIMLogFile OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "The log pathname that needs to be uploaded to the TFTP server when it is SIM enabled." ::= { agentBscTftpConfigMgmt 11 } agentBscTftpCfgServerIPAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IPv4 address of the TFTP server." ::= { agentBscTftpConfigMgmt 12 } agentBscTftpCfgServerIPv6Addr OBJECT-TYPE SYNTAX Ipv6Address MAX-ACCESS read-write STATUS current DESCRIPTION "The IPv6 address of the TFTP server." ::= { agentBscTftpConfigMgmt 13 } agentBscTftpCfgServerDomainName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "The domain name of the TFTP server." ::= { agentBscTftpConfigMgmt 14 } -- ----------------------------------------------------------------------------- -- agentBscCommunityEncryptionState -- ----------------------------------------------------------------------------- agentBscCommunityEncryptionState OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the encryption state on the SNMP community string." ::= { agentBasicConfig 29 } -- ----------------------------------------------------------------------------- -- agentSnmpUdpPort -- ----------------------------------------------------------------------------- agentSnmpUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the snmp udp port number." ::= { agentBasicConfig 30 } -- ----------------------------------------------------------------------------- -- agentResponseBroadcastRequest -- ----------------------------------------------------------------------------- agentResponseBroadcastRequest OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the response broadcast request state." ::= { agentBasicConfig 31 } -- ----------------------------------------------------------------------------- -- agentIpProtocolConfig -- ----------------------------------------------------------------------------- agentIpProtoConfig OBJECT IDENTIFIER ::= { agentGeneralMgmt 3 } agentIpNumOfIf OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of IP interfaces supported by this agent." ::= { agentIpProtoConfig 1 } agentIpTftpServerAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS obsolete DESCRIPTION "The IP address of the TFTP Server." ::= { agentIpProtoConfig 2 } agentIpGetIpFrom OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), bootp(3), dhcp(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if the agent will get its system IP address from a Bootp/DHCP server at start up." ::= { agentIpProtoConfig 3 } agentIpAutoconfig OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the status of automatically getting the configuration information from a TFTP server connected to the device." ::= { agentIpProtoConfig 4 } agentIpAutoconfigTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This timer is used to limit the length of time for getting the configuration information from a TFTP server connected to the device." ::= { agentIpProtoConfig 5 } -- End of agentIpIfTable -- ----------------------------------------------------------------------------- -- agentIptrapMangerTable -- ----------------------------------------------------------------------------- agentIpTrapManager OBJECT IDENTIFIER ::= { agentGeneralMgmt 4 } -- agentIpTrapManagerTable OBJECT-TYPE- -- SYNTAX SEQUENCE OF AgentIpTrapManagerEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "A list of trap managers that the SNMP traps will be sent to." -- ::= { agentIpTrapManager 1 } -- agentIpTrapManagerEntry OBJECT-TYPE -- SYNTAX AgentIpTrapManagerEntry -- MAX-ACCESS not-accessible -- STATUS obsolete -- DESCRIPTION -- "Each entry contains the particular trap manager settings." -- INDEX { agentIpTrapManagerIpAddr } -- ::= { agentIpTrapManagerTable 1 } -- ----------------------------------------------------------------------------- agentTrapManagerTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentTrapManagerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of trap managers that the SNMP traps will be sent to." ::= { agentIpTrapManager 2 } agentTrapManagerEntry OBJECT-TYPE SYNTAX AgentTrapManagerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains the particular trap manager's settings." INDEX { agentTrapManagerIndex } ::= { agentTrapManagerTable 1 } AgentTrapManagerEntry ::= SEQUENCE { agentTrapManagerIndex INTEGER, agentTrapManagerIpAddr IpAddress, agentTrapManagerComm DisplayString, agentTrapManagerMsgVer INTEGER, agentTrapManagerStatus INTEGER, agentTrapManagerUdpPort INTEGER } agentTrapManagerIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A value that uniquely identifies trapDestEntry." ::= { agentTrapManagerEntry 1 } agentTrapManagerIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The destination IP address for SNMP traps." ::= { agentTrapManagerEntry 2 } agentTrapManagerComm OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "The community string used to encode SNMP trap packets being sent to the trap manager." ::= { agentTrapManagerEntry 3 } agentTrapManagerMsgVer OBJECT-TYPE SYNTAX INTEGER { snmpAgentVersionDependent(1), v1Trap(2), v2Trap(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the version of trap packets that will be sent to this trap manager. The default setting is SNMP Agent Version Dependent. Note: Because some of these functions will be limited by the support of the system in question, some selected items may be invalid. If one of these items is selected, a bad value error message will prompt the user. " ::= { agentTrapManagerEntry 4 } agentTrapManagerStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether or not the trap should be sent to the trap manager." ::= { agentTrapManagerEntry 5 } agentTrapManagerUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Trap udp port number." ::= { agentTrapManagerEntry 6 } -- ----------------------------------------------------------------------------- -- agentPortTrapStateTable -- ----------------------------------------------------------------------------- agentPortTrapStateTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentPortTrapStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Use to Set/Get per port trap state." ::= { agentIpTrapManager 3 } agentPortTrapStateEntry OBJECT-TYPE SYNTAX AgentPortTrapStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an entry of the agentPortTrapStateTable." INDEX { agentTrapStatePortIndex } ::= { agentPortTrapStateTable 1 } AgentPortTrapStateEntry ::= SEQUENCE { agentTrapStatePortIndex INTEGER, agentPortTrapState INTEGER } agentTrapStatePortIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the port number." ::= { agentPortTrapStateEntry 1 } agentPortTrapState OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the port trap status." ::= { agentPortTrapStateEntry 2 } -- ----------------------------------------------------------------------------- -- Add for Slip_Console mode swtich 11-9-2001 WindChen -- ----------------------------------------------------------------------------- -- agentConsoleModeManager OBJECT IDENTIFIER ::= { agentGeneralMgmt 5 } -- ----------------------------------------------------------------------------- -- Slip Mode Manager -- ----------------------------------------------------------------------------- -- agentSlipModeManager OBJECT IDENTIFIER ::= { agentGeneralMgmt 6 } -- ----------------------------------------------------------------------------- -- Add common trap management -- ----------------------------------------------------------------------------- agentNotify OBJECT IDENTIFIER ::= { agentGeneralMgmt 7 } agentNotifMgmt OBJECT IDENTIFIER ::= { agentNotify 1 } agentNotifFirmware OBJECT IDENTIFIER ::= { agentNotify 2 } agentNotifyPrefix OBJECT IDENTIFIER ::= { agentNotifFirmware 0 } -- ----------------------------------------------------------------------------- -- agentNotifMgmt -- ----------------------------------------------------------------------------- -- systemSeverityControl OBJECT-TYPE -- SYNTAX AgentNotifyLevel -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Indicates the level of trap severity control. The system has a severity level control -- and each trap should have a severity control set. When trap events occur and its severity -- is higher than the system severity control level, the trap works as defined. If the event -- severity is lower than the system severity control level, the event is ignored as if it did not occur. -- " -- ::= { agentNotifMgmt 1 } notifFirmwareMgmt OBJECT IDENTIFIER ::= { agentNotifMgmt 2 } -- ----------------------------------------------------------------------------- -- agentNotifFirmware OBJECT IDENTIFIER ::= { agentNotifyPrefix 0 } -- ----------------------------------------------------------------------------- -- agentNotifFirmware -- ----------------------------------------------------------------------------- agentsystemRestart NOTIFICATION-TYPE OBJECTS { trapInfosystemRestart } STATUS current DESCRIPTION "This trap contains the reboot information." ::= { agentNotifyPrefix 1 } agentSaveToNVRAM NOTIFICATION-TYPE OBJECTS { unitID } STATUS current DESCRIPTION "This trap is sent whenever all the device configuration has been saved to NV-RAM." ::= { agentNotifyPrefix 2 } agentFileTransferStatusChange NOTIFICATION-TYPE OBJECTS { unitID, agentStatusFileTransfer } STATUS current DESCRIPTION "File transfer status change notification." ::= { agentNotifyPrefix 3 } agentSetToFactoryDefault NOTIFICATION-TYPE OBJECTS { unitID } STATUS current DESCRIPTION "This trap is sent whenever the 'set to factory default' setting has been processed. " ::= { agentNotifyPrefix 4 } agentGratuitousARPTrap NOTIFICATION-TYPE OBJECTS { agentGratuitousARPIpAddr, agentGratuitousARPMacAddr, agentGratuitousARPPortNumber, agentGratuitousARPInterfaceName } STATUS current DESCRIPTION "This trap is sent when there is an IP address conflict." ::={agentNotifyPrefix 5} agentLoginFailTrap NOTIFICATION-TYPE OBJECTS { agentLoginType, agentLoginAAAMethod, agentLoginUserName, agentLoginIpAddr, agentLoginMacAddr, agentLoginAAAServerAddr, agentLoginFailInfo } STATUS current DESCRIPTION "The trap is sent when a login has failed through one of the login types (console, Telnet, web, SSL or SSH)." ::={agentNotifyPrefix 6} agentFirmwareUpgrade NOTIFICATION-TYPE OBJECTS { swMultiImageVersion } STATUS current DESCRIPTION "This trap is sent when the process of upgrading the firmware via SNMP has finished." ::= { agentNotifyPrefix 7 } agentAccessFlashFailed NOTIFICATION-TYPE OBJECTS { agentAccessFlashOper, agentAccessFlashAddr } STATUS current DESCRIPTION "The trap is sent when access to the flash fails." ::={agentNotifyPrefix 8} agentCfgOperCompleteTrap NOTIFICATION-TYPE OBJECTS { unitID, agentCfgOperate, agentLoginUserName } STATUS current DESCRIPTION "The trap is sent when the configuration is completely saved, uploaded or downloaded." ::={agentNotifyPrefix 9} -- ----------------------------------------------------------------------------- -- agentNotifEquipment -- ----------------------------------------------------------------------------- -- ----------------------------------------------------------------------------- -- notificationBindings -- ----------------------------------------------------------------------------- notificationBindings OBJECT IDENTIFIER ::= { agentNotifFirmware 1 } unitID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The unit ID of the device which triggered the event." ::= { notificationBindings 1 } trapInfosystemRestart OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the last time the device rebooted. " ::= { notificationBindings 2 } agentGratuitousARPIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "A duplicate IP address with the switch already exists." ::={notificationBindings 3} agentGratuitousARPMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object is the MAC address of the device which has the duplicate IP address." ::={notificationBindings 4} agentGratuitousARPPortNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This indicates the portNum with a string. For example, if the device is in standalone mode, and the port number is 23, the string should be 23. If the device is in stacking mode, and the unit ID is 2, and the port number is 3, the string should be 2:3. " ::={notificationBindings 5} agentLoginType OBJECT-TYPE SYNTAX INTEGER { console(1), telnet(2), web(3), ssl(4), ssh(5) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The type is the user login method type." ::= { notificationBindings 6 } agentLoginAAAMethod OBJECT-TYPE SYNTAX INTEGER { none(1), local(2), server(3) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This method is the AAA login method." ::= { notificationBindings 7 } agentLoginUserName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object is the name of the user that failed to login to the switch." ::= { notificationBindings 8 } agentLoginIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object is the login type from the IP address." ::= { notificationBindings 9 } agentLoginMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object is the login type from a MAC address." ::= { notificationBindings 10 } agentLoginAAAServerAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object is the login type through a console authenticated by an AAA server." ::= { notificationBindings 11 } agentLoginFailInfo OBJECT-TYPE SYNTAX INTEGER { other(1), authenticate-fail(2), server-timeout(3) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates the reason for the login failure." ::= { notificationBindings 12 } agentAccessFlashOper OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates the operation of the access flash failure." ::= { notificationBindings 13 } agentAccessFlashAddr OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates the address of the access flash failure." ::= { notificationBindings 14 } agentCfgOperate OBJECT-TYPE SYNTAX INTEGER { save(1), upload(2), download(3) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates the operation type of the configuration." ::= { notificationBindings 15 } END