-- ***************************************************************** -- DLINKSW-ENTITY-EXT-MIB.mib : D-Link Entity Extensions MIB -- -- Copyright (c) 2013 D-Link Corporation, all rights reserved. -- -- ***************************************************************** DLINKSW-ENTITY-EXT-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Integer32 FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF dlinkIndustrialCommon FROM DLINK-ID-REC-MIB; dlinkSwEntityExtMIB MODULE-IDENTITY LAST-UPDATED "201309060000Z" ORGANIZATION "D-Link Corp." CONTACT-INFO " D-Link Corporation Postal: No. 289, Sinhu 3rd Rd., Neihu District, Taipei City 114, Taiwan, R.O.C Tel: +886-2-66000123 E-mail: tsd@dlink.com.tw " DESCRIPTION "This MIB module provides essential information about the system and defines the managed objects that support the monitoring of alarms generated by physical entities, including temperature sensors, fans and power supplies. " REVISION "201309060000Z" DESCRIPTION "Add dEntityExtFactoryResetButton to support factory reset button trap." REVISION "201303130000Z" DESCRIPTION "This is the first version of this MIB." ::= { dlinkIndustrialCommon 5 } -- ----------------------------------------------------------------------------- dEntityExtNotifications OBJECT IDENTIFIER ::= { dlinkSwEntityExtMIB 0 } dEntityExtObjects OBJECT IDENTIFIER ::= { dlinkSwEntityExtMIB 1 } dEntityExtConformance OBJECT IDENTIFIER ::= { dlinkSwEntityExtMIB 2 } -- ----------------------------------------------------------------------------- dEntityExtEnvObjects OBJECT IDENTIFIER ::= { dEntityExtObjects 1 } dEntityExtEnvTempTable OBJECT-TYPE SYNTAX SEQUENCE OF DEntityExtEnvTempEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table consists of a list of temperature information." ::= { dEntityExtEnvObjects 1 } dEntityExtEnvTempEntry OBJECT-TYPE SYNTAX DEntityExtEnvTempEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry represents the temperature status of a testpoint. " INDEX { dEntityExtEnvTempUnitId, dEntityExtEnvTempIndex } ::= { dEntityExtEnvTempTable 1 } DEntityExtEnvTempEntry ::= SEQUENCE { dEntityExtEnvTempUnitId Unsigned32, dEntityExtEnvTempIndex Integer32, dEntityExtEnvTempDescr DisplayString, dEntityExtEnvTempCurrent Integer32, dEntityExtEnvTempThresholdLow Integer32, dEntityExtEnvTempThresholdHigh Integer32, dEntityExtEnvTempStatus INTEGER } dEntityExtEnvTempUnitId OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the unit (stacking device) or slot (chassis device) ID at which the testpoint is located." ::= { dEntityExtEnvTempEntry 1 } dEntityExtEnvTempIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is used to uniquely identify the testpoint within a unit/slot. This index is for SNMP purposes only, and has no intrinsic meaning." ::= { dEntityExtEnvTempEntry 2 } dEntityExtEnvTempDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object provides human-sensible identification for the testpoint. e.g. 'Inlet', 'Center', 'Outlet'. " ::= { dEntityExtEnvTempEntry 3 } dEntityExtEnvTempCurrent OBJECT-TYPE SYNTAX Integer32 UNITS "degrees Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the current measurement of the testpoint." ::= { dEntityExtEnvTempEntry 4 } dEntityExtEnvTempThresholdLow OBJECT-TYPE SYNTAX Integer32 UNITS "degrees Celsius" MAX-ACCESS read-write STATUS current DESCRIPTION "The object indicates the minimum acceptable reading of the testpoint in degrees Celsius. " ::= { dEntityExtEnvTempEntry 5 } dEntityExtEnvTempThresholdHigh OBJECT-TYPE SYNTAX Integer32 UNITS "degrees Celsius" MAX-ACCESS read-write STATUS current DESCRIPTION "The object indicates the maximum acceptable reading of the testpoint in degrees Celsius. " ::= { dEntityExtEnvTempEntry 6 } dEntityExtEnvTempStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), abnormal(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The object indicates the current temperature is over the thresholds or not. 'abnormal' indicates the temperature is over the thresholds. 'ok' indicates the temperature is not over the thresholds." ::= { dEntityExtEnvTempEntry 7 } -- ----------------------------------------------------------------------------- dEntityExtEnvFanTable OBJECT-TYPE SYNTAX SEQUENCE OF DEntityExtEnvFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table is used to display the status of fans." ::= { dEntityExtEnvObjects 2 } dEntityExtEnvFanEntry OBJECT-TYPE SYNTAX DEntityExtEnvFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry represents a fan status. " INDEX { dEntityExtEnvFanUnitId, dEntityExtEnvFanIndex } ::= { dEntityExtEnvFanTable 1 } DEntityExtEnvFanEntry ::= SEQUENCE { dEntityExtEnvFanUnitId Unsigned32, dEntityExtEnvFanIndex Integer32, dEntityExtEnvFanDescr DisplayString, dEntityExtEnvFanStatus INTEGER } dEntityExtEnvFanUnitId OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the unit (stacking device) or slot (chassis device) ID at which the fan is located." ::= { dEntityExtEnvFanEntry 1 } dEntityExtEnvFanIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is used to uniquely identify the fan within a unit/slot. This index is for SNMP purposes only, and has no intrinsic meaning." ::= { dEntityExtEnvFanEntry 2 } dEntityExtEnvFanDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object provides human-sensible identification for the fan. e.g. 'Left 1' for the first fan on the left. " ::= { dEntityExtEnvFanEntry 3 } dEntityExtEnvFanStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), fault(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the fan status." ::= { dEntityExtEnvFanEntry 4 } -- ----------------------------------------------------------------------------- dEntityExtEnvPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF DEntityExtEnvPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table is used to display the status of the power modules." ::= { dEntityExtEnvObjects 3 } dEntityExtEnvPowerEntry OBJECT-TYPE SYNTAX DEntityExtEnvPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains the information of a power module." INDEX { dEntityExtEnvPowerUnitId, dEntityExtEnvPowerIndex } ::= { dEntityExtEnvPowerTable 1 } DEntityExtEnvPowerEntry ::= SEQUENCE { dEntityExtEnvPowerUnitId Unsigned32, dEntityExtEnvPowerIndex Unsigned32, dEntityExtEnvPowerDescr DisplayString, dEntityExtEnvPowerUsedPower Unsigned32, dEntityExtEnvPowerMaxPower Unsigned32, dEntityExtEnvPowerStatus INTEGER } dEntityExtEnvPowerUnitId OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the unit (stacking device) or slot (chassis device) ID at which the power module is located." ::= { dEntityExtEnvPowerEntry 1 } dEntityExtEnvPowerIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the ID of the power module. This object is used to uniquely identify the power module. This index is for SNMP purposes only, and has no intrinsic meaning. " ::= { dEntityExtEnvPowerEntry 2 } dEntityExtEnvPowerDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object provides human-sensible information for the power module. e.g. '#1 (internal)', '#2 (external)'. " ::= { dEntityExtEnvPowerEntry 3 } dEntityExtEnvPowerUsedPower OBJECT-TYPE SYNTAX Unsigned32 UNITS "watts" MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the amount of the power that has been allocated. " ::= { dEntityExtEnvPowerEntry 4 } dEntityExtEnvPowerMaxPower OBJECT-TYPE SYNTAX Unsigned32 UNITS "watts" MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates maximum power which the power module can supply. " ::= { dEntityExtEnvPowerEntry 5 } dEntityExtEnvPowerStatus OBJECT-TYPE SYNTAX INTEGER { inOperation(1), failed(2), empty(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the status of the power." ::= { dEntityExtEnvPowerEntry 6 } -- ----------------------------------------------------------------------------- dEntityExtEnvAirFlowTable OBJECT-TYPE SYNTAX SEQUENCE OF DEntityExtEnvAirFlowEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table is used to display the status of the air flow function." ::= { dEntityExtEnvObjects 4 } dEntityExtEnvAirFlowEntry OBJECT-TYPE SYNTAX DEntityExtEnvAirFlowEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains the information of the air flow function." INDEX { dEntityExtEnvAirFlowUnitId } ::= { dEntityExtEnvAirFlowTable 1 } DEntityExtEnvAirFlowEntry ::= SEQUENCE { dEntityExtEnvAirFlowUnitId Unsigned32, dEntityExtEnvAirFlowStatus INTEGER } dEntityExtEnvAirFlowUnitId OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the unit (stacking device) or slot (chassis device) ID at which the air flow module is located." ::= { dEntityExtEnvAirFlowEntry 1 } dEntityExtEnvAirFlowStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), abnormal(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the status of the air flow. The fans' air flow direction must match the system's air flow direction to form an integrated air flow. For example: In DXS-3600, the normal fans' air flow direction must match the power fan's air flow direction. The power fan blow the cold air from outside to inside, all the normal fans must blow the hot air from inside to outside. Or the power fan blow the hot air from inside to outside, all the normal fans must blow the cold air from outside to inside. If one or more fans' air flow direction does not match the system's air flow direction, it will form an abnormal air flow. Then this log message will be triggered. ok(1) : A recover event indicates the air flow back to normal. abnormal(2): An alarm event indicates the air flow detects abnormal. " ::= { dEntityExtEnvAirFlowEntry 2 } -- ----------------------------------------------------------------------------- dEntityExtEnvTrap OBJECT IDENTIFIER ::= { dEntityExtObjects 2 } dEntityExtEnvNotifyEnable OBJECT-TYPE SYNTAX BITS { fan(0), power(1), temperature(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether a specified notification is enabled or not. If a bit corresponding to a notification is set to 1, then the specified notification can be generated. fan(0) - fan trap state for warning fan event (fan failed or fan recover). power(1) - power trap state for warning power event (power failure or power recovery). temperature(2) - temperature trap state for warning temperature event (temperature exceeds the thresholds or temperature recover). " ::= { dEntityExtEnvTrap 1 } -- ----------------------------------------------------------------------------- dEntityExtUnitTable OBJECT-TYPE SYNTAX SEQUENCE OF DEntityExtUnitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table is used to display information of units." ::= { dEntityExtObjects 3 } dEntityExtUnitEntry OBJECT-TYPE SYNTAX DEntityExtUnitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains essential information of a unit." INDEX { dEntityExtUnitIndex } ::= { dEntityExtUnitTable 1 } DEntityExtUnitEntry ::= SEQUENCE { dEntityExtUnitIndex Unsigned32, dEntityExtUnitStatus INTEGER, dEntityExtUnitUpTime Unsigned32 } dEntityExtUnitIndex OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the unit (stacking device) or slot (chassis device) ID. " ::= { dEntityExtUnitEntry 1 } dEntityExtUnitStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), failed(2), empty(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object represents the status of the unit: ok(1) - This indicates the unit is okay. failed(2) - This indicates the unit fails due to some reason. empty(3) - This indicates that the unit is provisioned but currently not installed. " ::= { dEntityExtUnitEntry 2 } dEntityExtUnitUpTime OBJECT-TYPE SYNTAX Unsigned32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object provides the up time in units of seconds for the unit since it was last re-initialized. " ::= { dEntityExtUnitEntry 3 } -- ----------------------------------------------------------------------------- dEntityExtMemoryUtilTable OBJECT-TYPE SYNTAX SEQUENCE OF DEntityExtMemoryUtilEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table is used to display memory utilization information." ::= { dEntityExtObjects 4 } dEntityExtMemoryUtilEntry OBJECT-TYPE SYNTAX DEntityExtMemoryUtilEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains memory utilization information. " INDEX { dEntityExtMemUtilUnitId, dEntityExtMemUtilType } ::= { dEntityExtMemoryUtilTable 1 } DEntityExtMemoryUtilEntry ::= SEQUENCE { dEntityExtMemUtilUnitId Integer32, dEntityExtMemUtilType INTEGER, dEntityExtMemUtilTotal Unsigned32, dEntityExtMemUtilUsed Unsigned32, dEntityExtMemUtilFree Unsigned32 } dEntityExtMemUtilUnitId OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the unit (stacking device) or slot (chassis device) ID. " ::= { dEntityExtMemoryUtilEntry 1 } dEntityExtMemUtilType OBJECT-TYPE SYNTAX INTEGER { dram(1), flash(2), nvram(3) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "The object indicates the memory type of the entry." ::= { dEntityExtMemoryUtilEntry 2 } dEntityExtMemUtilTotal OBJECT-TYPE SYNTAX Unsigned32 UNITS "KB" MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the total memory size of the entry." ::= { dEntityExtMemoryUtilEntry 3 } dEntityExtMemUtilUsed OBJECT-TYPE SYNTAX Unsigned32 UNITS "KB" MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the used memory size of the entry." ::= { dEntityExtMemoryUtilEntry 4 } dEntityExtMemUtilFree OBJECT-TYPE SYNTAX Unsigned32 UNITS "KB" MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the free memory size of the entry." ::= { dEntityExtMemoryUtilEntry 5 } -- ----------------------------------------------------------------------------- dEntityExtCpuUtilTable OBJECT-TYPE SYNTAX SEQUENCE OF DEntityExtCpuUtilEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table is used to display CPU utilization information." ::= { dEntityExtObjects 7 } dEntityExtCpuUtilEntry OBJECT-TYPE SYNTAX DEntityExtCpuUtilEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains CPU information." INDEX { dEntityExtCpuUtilUnitId, dEntityExtCpuUtilCpuID } ::= { dEntityExtCpuUtilTable 1 } DEntityExtCpuUtilEntry ::= SEQUENCE { dEntityExtCpuUtilUnitId Unsigned32, dEntityExtCpuUtilCpuID Unsigned32, dEntityExtCpuUtilFiveSeconds Unsigned32, dEntityExtCpuUtilOneMinute Unsigned32, dEntityExtCpuUtilFiveMinutes Unsigned32 } dEntityExtCpuUtilUnitId OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the unit (stacking device) or slot (chassis device) ID. " ::= { dEntityExtCpuUtilEntry 1 } dEntityExtCpuUtilCpuID OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is used to uniquely identify the CPU within a unit (multiprocessing system)." ::= { dEntityExtCpuUtilEntry 2 } dEntityExtCpuUtilFiveSeconds OBJECT-TYPE SYNTAX Unsigned32 UNITS "percentage" MAX-ACCESS read-only STATUS current DESCRIPTION "This objects indicates the overall CPU busy percentage in the last 5 second period. The value will be between 0% (idle) and 100% (very busy). " ::= { dEntityExtCpuUtilEntry 3 } dEntityExtCpuUtilOneMinute OBJECT-TYPE SYNTAX Unsigned32 UNITS "percentage" MAX-ACCESS read-only STATUS current DESCRIPTION "This objects indicates the overall CPU busy percentage in the last 1 minute period. The value will be between 0% (idle) and 100% (very busy). " ::= { dEntityExtCpuUtilEntry 4 } dEntityExtCpuUtilFiveMinutes OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This objects indicates the overall CPU busy percentage in the last 5 minute period. The value will be between 0% (idle) and 100% (very busy). " ::= { dEntityExtCpuUtilEntry 5 } -- ----------------------------------------------------------------------------- dEntityExtVersionTable OBJECT-TYPE SYNTAX SEQUENCE OF DEntityExtVersionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table is used to display version information of units." ::= { dEntityExtObjects 8 } dEntityExtVersionEntry OBJECT-TYPE SYNTAX DEntityExtVersionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains version information of a unit." INDEX { dEntityExtVersionUnitId} ::= { dEntityExtVersionTable 1 } DEntityExtVersionEntry ::= SEQUENCE { dEntityExtVersionUnitId Unsigned32, dEntityExtVersionBootloader DisplayString, dEntityExtVersionRuntime DisplayString } dEntityExtVersionUnitId OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the unit (stacking device) or slot (chassis device) ID. " ::= { dEntityExtVersionEntry 1 } dEntityExtVersionBootloader OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the bootloader version of the unit. " ::= { dEntityExtVersionEntry 2 } dEntityExtVersionRuntime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the firmware version of one unit. " ::= { dEntityExtVersionEntry 3 } -- ----------------------------------------------------------------------------- -- Notifications -- ----------------------------------------------------------------------------- dEntityExtFanStatusChg NOTIFICATION-TYPE OBJECTS { dEntityExtEnvFanUnitId, dEntityExtEnvFanIndex, dEntityExtEnvFanStatus } STATUS current DESCRIPTION "This trap indicates a fan fails (dEntityExtEnvFanStatus is 'fault') or recovers (dEntityExtEnvFanStatus is 'ok'). " ::= { dEntityExtNotifications 1 } dEntityExtThermalStatusChg NOTIFICATION-TYPE OBJECTS { dEntityExtEnvTempUnitId, dEntityExtEnvTempIndex, dEntityExtEnvTempStatus } STATUS current DESCRIPTION "This trap indicates a thermal alarms (dEntityExtEnvTempStatus is 'abnormal') or recovers (dEntityExtEnvTempStatus is 'ok'). " ::= { dEntityExtNotifications 2 } dEntityExtPowerStatusChg NOTIFICATION-TYPE OBJECTS { dEntityExtEnvPowerUnitId, dEntityExtEnvPowerIndex, dEntityExtEnvPowerStatus } STATUS current DESCRIPTION "This trap indicates a power module fails, recovers or is removed. " ::= { dEntityExtNotifications 3 } dEntityExtAirFlowChg NOTIFICATION-TYPE OBJECTS { dEntityExtEnvAirFlowUnitId, dEntityExtEnvAirFlowStatus } STATUS current DESCRIPTION "This trap is triggered when the air flow status is changed from 'ok' to 'abnormal' and vice versa. dEntityExtEnvAirFlowStatus indicates the current (new) fan air flow state. " ::= { dEntityExtNotifications 4 } dEntityExtFactoryResetButton NOTIFICATION-TYPE OBJECTS { dEntityExtUnitIndex } STATUS current DESCRIPTION "This trap is triggered when the factory reset button was pressed. " ::= { dEntityExtNotifications 5 } -- ----------------------------------------------------------------------------- -- MIB Conformance statements -- ----------------------------------------------------------------------------- dEntityExtMIBCompliances OBJECT IDENTIFIER ::= { dEntityExtConformance 1 } dEntityExtMIBGroups OBJECT IDENTIFIER ::= { dEntityExtConformance 2 } dEntityExtCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for entities which implement the DLINKSW-ENTITY-EXT-MIB." MODULE -- this module MANDATORY-GROUPS { dEntityExtSystemInfoGroup } GROUP dEntityExtTempGroup DESCRIPTION "This group is mandatory if monitoring environment temperature is supported." OBJECT dEntityExtEnvTempThresholdLow MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT dEntityExtEnvTempThresholdHigh MIN-ACCESS read-only DESCRIPTION "Write access is not required." GROUP dEntityExtThermalNotifGroup DESCRIPTION "This group is mandatory if monitoring environment temperature is supported." GROUP dEntityExtFanGroup DESCRIPTION "This group is mandatory if monitoring fan is supported." GROUP dEntityExtFanNotifGroup DESCRIPTION "This group is mandatory if monitoring fan is supported." GROUP dEntityExtPowerGroup DESCRIPTION "This group is mandatory if monitoring power is supported." GROUP dEntityExtPowerNotifGroup DESCRIPTION "This group is mandatory if monitoring power is supported." GROUP dEntityExtAirFlowNotifGroup DESCRIPTION "This group is mandatory if monitoring air flow is supported." GROUP dEntityExtGenericNotifInfoGroup DESCRIPTION "This group is mandatory if one kind of notification is supported." ::= { dEntityExtMIBCompliances 1 } -- Units of Conformance dEntityExtTempGroup OBJECT-GROUP OBJECTS { dEntityExtEnvTempDescr, dEntityExtEnvTempCurrent, dEntityExtEnvTempThresholdLow, dEntityExtEnvTempThresholdHigh, dEntityExtEnvTempStatus } STATUS current DESCRIPTION "A collection of objects provides information of the system temperature." ::= { dEntityExtMIBGroups 1 } dEntityExtFanGroup OBJECT-GROUP OBJECTS { dEntityExtEnvFanDescr, dEntityExtEnvFanStatus } STATUS current DESCRIPTION "A collection of objects providing informations of fans." ::= { dEntityExtMIBGroups 2 } dEntityExtPowerGroup OBJECT-GROUP OBJECTS { dEntityExtEnvPowerDescr, dEntityExtEnvPowerUsedPower, dEntityExtEnvPowerMaxPower, dEntityExtEnvPowerStatus } STATUS current DESCRIPTION "A collection of objects providing information of power modules. " ::= { dEntityExtMIBGroups 3 } dEntityExtSystemInfoGroup OBJECT-GROUP OBJECTS { dEntityExtUnitStatus, dEntityExtUnitUpTime, dEntityExtMemUtilTotal, dEntityExtMemUtilUsed, dEntityExtMemUtilFree, dEntityExtCpuUtilFiveSeconds, dEntityExtCpuUtilOneMinute, dEntityExtCpuUtilFiveMinutes, dEntityExtVersionBootloader, dEntityExtVersionRuntime } STATUS current DESCRIPTION "A collection of objects provides information of the system temperature." ::= { dEntityExtMIBGroups 4 } dEntityExtGenericNotifInfoGroup OBJECT-GROUP OBJECTS { dEntityExtEnvNotifyEnable } STATUS current DESCRIPTION "A collection of objects provides generic information for binding variables of notification. " ::= { dEntityExtMIBGroups 5 } dEntityExtFanNotifGroup NOTIFICATION-GROUP NOTIFICATIONS { dEntityExtFanStatusChg } STATUS current DESCRIPTION "A collection of notifications for indicating the status change of fans." ::= { dEntityExtMIBGroups 6 } dEntityExtThermalNotifGroup NOTIFICATION-GROUP NOTIFICATIONS { dEntityExtThermalStatusChg } STATUS current DESCRIPTION "A collection of notifications for indicating the status change of thermals." ::= { dEntityExtMIBGroups 7 } dEntityExtPowerNotifGroup NOTIFICATION-GROUP NOTIFICATIONS { dEntityExtPowerStatusChg } STATUS current DESCRIPTION "A collection of notifications for indicating the status change of power module." ::= { dEntityExtMIBGroups 8 } dEntityExtAirFlowNotifGroup NOTIFICATION-GROUP NOTIFICATIONS { dEntityExtAirFlowChg } STATUS current DESCRIPTION "A collection of notifications for indicating the status change of the air flow." ::= { dEntityExtMIBGroups 9 } dEntityExtFactoryResetButtonNotifGroup NOTIFICATION-GROUP NOTIFICATIONS { dEntityExtFactoryResetButton } STATUS current DESCRIPTION "A collection of notifications for indicating the factory reset button." ::= { dEntityExtMIBGroups 10 } END