-- Title: DPS_V41.MIB -- Version: v4.1 -- -- Copyright @ 1997-2004 DPS Inc. All Rights Reserved -- -- This MIB defines objects for the DPS products. -- -- DPS-MIB-V38 DEFINITIONS ::= BEGIN IMPORTS DisplayString, sysDescr, sysLocation FROM RFC1213-MIB OBJECT-TYPE FROM RFC1212-MIB enterprises FROM RFC1155-SMI TRAP-TYPE FROM RFC-1215; dpsInc OBJECT IDENTIFIER ::= {enterprises 2682} dpsAlarmControl OBJECT IDENTIFIER ::= {dpsInc 1} tmonXM OBJECT IDENTIFIER ::= {dpsAlarmControl 1} tmonIdent OBJECT IDENTIFIER ::= {tmonXM 1} tmonIdentManufacturer OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The TMON/XM Unit manufacturer." ::= {tmonIdent 1} tmonIdentModel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The TMON/XM model designation." ::= {tmonIdent 2} tmonIdentSoftwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The TMON/XM SNMP Agent software version." ::= {tmonIdent 3} tmonAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF TMonAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of TMon Alarm-specific information." ::= {tmonXM 2} tmonAlarmEntry OBJECT-TYPE SYNTAX TMonAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about a particular TMon alarm." INDEX {tmonAIndex} ::= {tmonAlarmTable 1} TMonAlarmEntry ::= SEQUENCE { tmonAIndex INTEGER, tmonASite DisplayString, tmonADesc DisplayString, tmonAState DisplayString, tmonASeverity DisplayString, tmonAChgDate DisplayString, tmonAChgTime DisplayString, tmonAAuxDesc DisplayString, tmonADispDesc DisplayString, tmonAPntType INTEGER, tmonAPort INTEGER, tmonAAddress INTEGER, tmonADisplay INTEGER, tmonAPoint INTEGER, tmonAIPAddr DisplayString, tmonADevDesc DisplayString } tmonAIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Tmon alarm table index (1..NumberOfAlarms)." ::={tmonAlarmEntry 1} tmonASite OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The site of the alarm (i.e. Atlanta Hub, Sub-Station H32)." ::= {tmonAlarmEntry 2} tmonADesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A user-defined text string associated with the alarm (i.e. South Door, Generator, Power Grid 1)." ::= {tmonAlarmEntry 3} tmonAState OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm state." ::= {tmonAlarmEntry 4} tmonASeverity OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The severity of the last alarm event." ::= {tmonAlarmEntry 5} tmonAChgDate OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The date (mm/dd/yy) of the last alarm event." ::= {tmonAlarmEntry 6} tmonAChgTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The time (hh:mm:ss) of the last alarm event." ::= {tmonAlarmEntry 7} tmonAAuxDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "An auxiliary user-defined text string associated with the alarm (i.e. This remote needs servicing)." ::= {tmonAlarmEntry 8} tmonADispDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A description of the display on which this point appears." ::= {tmonAlarmEntry 9} tmonAPntType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Type of this point." ::={tmonAlarmEntry 10} tmonAPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Port on which this point is reported." ::={tmonAlarmEntry 11} tmonAAddress OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Address of unit reporting this point." ::={tmonAlarmEntry 12} tmonADisplay OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Display on which this point appears." ::={tmonAlarmEntry 13} tmonAPoint OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index into display of this point." ::={tmonAlarmEntry 14} tmonAIPAddr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The IP Address of the device on which this point appears." ::= {tmonAlarmEntry 16} tmonADevDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A description of the device on which this point appears." ::= {tmonAlarmEntry 17} -- structure used to issue a command to tmonXM element tmonCommandGrid OBJECT IDENTIFIER ::= {tmonXM 3} tmonCPType OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Tmon point type." ::= {tmonCommandGrid 1} tmonCPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Tmon port number." ::= {tmonCommandGrid 2} tmonCAddress OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Tmon_port address number." ::= {tmonCommandGrid 3} tmonCDisplay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Tmon_port_address display number." ::= {tmonCommandGrid 4} tmonCPoint OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-write STATUS mandatory DESCRIPTION "Tmon_port_display point number (1-64)." ::= {tmonCommandGrid 5} tmonCEvent OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Tmon event ID." ::= {tmonCommandGrid 6} tmonCAction OBJECT-TYPE SYNTAX INTEGER { latch(1), release(2), momentary(3), ack(17), tag(18), untag(19) } ACCESS read-write STATUS mandatory DESCRIPTION "Requested command action (tmonXM will ignore if invalid)." ::= {tmonCommandGrid 7} tmonCAuxText OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "An auxiliary user-defined text string associated with the command (i.e. User_initials)." ::= {tmonCommandGrid 8} tmonCResult OBJECT-TYPE SYNTAX INTEGER { success(1), failure(2), pending(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Command result." ::= {tmonCommandGrid 9} dpsRTU OBJECT IDENTIFIER ::= {dpsAlarmControl 2} dpsRTUIdent OBJECT IDENTIFIER ::= {dpsRTU 1} dpsRTUManufacturer OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Remote Telemetry Unit manufacturer." ::= {dpsRTUIdent 1} dpsRTUModel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The RTU model designation." ::= {dpsRTUIdent 2} dpsRTUFirmwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The RTU firmware version." ::= {dpsRTUIdent 3} dpsRTUDateTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The RTU system date and time." ::= {dpsRTUIdent 4} dpsRTUSyncReq OBJECT-TYPE SYNTAX INTEGER { sync(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Caution: SETting this object initiates traps for all standing alarms." ::= {dpsRTUIdent 5} -- structure used to access displays managed by this RTU dpsRTUDisplayGrid OBJECT-TYPE SYNTAX SEQUENCE OF DPSrtuDispEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Holds information on displays managed by the RTU." ::= {dpsRTU 2} dpsRTUDisplayEntry OBJECT-TYPE SYNTAX DPSrtuDispEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about a particular RTU display." INDEX {dpsRTUPort, dpsRTUAddress, dpsRTUDisplay} ::= {dpsRTUDisplayGrid 1} DPSrtuDispEntry ::= SEQUENCE { dpsRTUPort INTEGER, dpsRTUAddress INTEGER, dpsRTUDisplay INTEGER, dpsRTUDispDesc DisplayString, dpsRTUPntMap DisplayString } dpsRTUPort OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "RTU port number." ::= {dpsRTUDisplayEntry 1} dpsRTUAddress OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "RTU_port address number." ::= {dpsRTUDisplayEntry 2} dpsRTUDisplay OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "RTU_port_address display number." ::= {dpsRTUDisplayEntry 3} dpsRTUDispDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A description of the associated display." ::= {dpsRTUDisplayEntry 4} dpsRTUPntMap OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A map of the points appearing in this display." ::= {dpsRTUDisplayEntry 5} -- structure used to issue a control to a managed point dpsRTUControlGrid OBJECT IDENTIFIER ::= {dpsRTU 3} dpsRTUCPort OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "RTU port number." ::= {dpsRTUControlGrid 1} dpsRTUCAddress OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "RTU_port address number." ::= {dpsRTUControlGrid 2} dpsRTUCDisplay OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "RTU_port_address display number." ::= {dpsRTUControlGrid 3} dpsRTUCPoint OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-write STATUS mandatory DESCRIPTION "RTU_port_display point number (1-64)." ::= {dpsRTUControlGrid 4} dpsRTUCAction OBJECT-TYPE SYNTAX INTEGER { latch(1), release(2), momentary(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Requested action on point (RTU will ignore if invalid)." ::= {dpsRTUControlGrid 5} dpsRTUAlarmGrid OBJECT-TYPE SYNTAX SEQUENCE OF DPSrtuAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Holds individual alarm point information." ::= {dpsRTU 5} dpsRTUAlarmEntry OBJECT-TYPE SYNTAX DPSrtuAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Detailed information about a particular RTU display." INDEX {dpsRTUAPort, dpsRTUAAddress, dpsRTUADisplay, dpsRTUAPoint} ::= {dpsRTUAlarmGrid 1} DPSrtuAlarmEntry ::= SEQUENCE { dpsRTUAPort INTEGER, dpsRTUAAddress INTEGER, dpsRTUADisplay INTEGER, dpsRTUAPoint INTEGER, dpsRTUAPntDesc DisplayString, dpsRTUAState DisplayString } dpsRTUAPort OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "RTU port number." ::= {dpsRTUAlarmEntry 1} dpsRTUAAddress OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "RTU_port address number." ::= {dpsRTUAlarmEntry 2} dpsRTUADisplay OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "RTU_port_address display number." ::= {dpsRTUAlarmEntry 3} dpsRTUAPoint OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "RTU_port_address_display point number." ::= {dpsRTUAlarmEntry 4} dpsRTUAPntDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A description of this point." ::= {dpsRTUAlarmEntry 5} dpsRTUAState OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The current state of this point." ::= {dpsRTUAlarmEntry 6} --Table for accessing analog channel value analogChannels OBJECT-TYPE SYNTAX SEQUENCE OF ChannelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Holds information on analog channels" ::= {dpsRTU 6} channelEntry OBJECT-TYPE SYNTAX ChannelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about a particular channel" INDEX {channelNumber} ::= {analogChannels 1} ChannelEntry ::= SEQUENCE { channelNumber INTEGER, enabled INTEGER, description DisplayString, value DisplayString, thresholds INTEGER } channelNumber OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "Input channel number" ::= {channelEntry 1} enabled OBJECT-TYPE SYNTAX INTEGER { disabled (0), enabled (1) } ACCESS read-only STATUS mandatory DESCRIPTION "Enable status of channel" ::= {channelEntry 2} description OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The user defined description of the channel" ::= {channelEntry 3} value OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The current value of the channel" ::= {channelEntry 4} thresholds OBJECT-TYPE SYNTAX INTEGER { noAlarms (0), minorUnder (1), minorOver (2), majorUnder (3), majorOver (4), notDetected (5) } ACCESS read-only STATUS mandatory DESCRIPTION "Highest threshold level crossed, if MJ, MN is assumed" ::= {channelEntry 5} -- TRAP definitions tmonCRalarmSet TRAP-TYPE ENTERPRISE tmonXM VARIABLES { tmonASite, tmonADesc, tmonAState, tmonASeverity, tmonAChgDate, tmonAChgTime, tmonAAuxDesc, tmonADispDesc, tmonAPntType, tmonAPort, tmonAAddress, tmonADisplay, tmonAPoint, tmonCEvent, tmonAIPAddr, tmonADevDesc } DESCRIPTION "Generated when a critical alarm is set." ::= 10 tmonCRalarmClr TRAP-TYPE ENTERPRISE tmonXM VARIABLES { tmonASite, tmonADesc, tmonAState, tmonASeverity, tmonAChgDate, tmonAChgTime, tmonAAuxDesc, tmonADispDesc, tmonAPntType, tmonAPort, tmonAAddress, tmonADisplay, tmonAPoint, tmonCEvent, tmonAIPAddr, tmonADevDesc } DESCRIPTION "Generated when a critical alarm clears." ::= 11 tmonMJalarmSet TRAP-TYPE ENTERPRISE tmonXM VARIABLES { tmonASite, tmonADesc, tmonAState, tmonASeverity, tmonAChgDate, tmonAChgTime, tmonAAuxDesc, tmonADispDesc, tmonAPntType, tmonAPort, tmonAAddress, tmonADisplay, tmonAPoint, tmonCEvent, tmonAIPAddr, tmonADevDesc } DESCRIPTION "Generated when a major alarm is set." ::= 12 tmonMJalarmClr TRAP-TYPE ENTERPRISE tmonXM VARIABLES { tmonASite, tmonADesc, tmonAState, tmonASeverity, tmonAChgDate, tmonAChgTime, tmonAAuxDesc, tmonADispDesc, tmonAPntType, tmonAPort, tmonAAddress, tmonADisplay, tmonAPoint, tmonCEvent, tmonAIPAddr, tmonADevDesc } DESCRIPTION "Generated when a major alarm clears." ::= 13 tmonMNalarmSet TRAP-TYPE ENTERPRISE tmonXM VARIABLES { tmonASite, tmonADesc, tmonAState, tmonASeverity, tmonAChgDate, tmonAChgTime, tmonAAuxDesc, tmonADispDesc, tmonAPntType, tmonAPort, tmonAAddress, tmonADisplay, tmonAPoint, tmonCEvent, tmonAIPAddr, tmonADevDesc } DESCRIPTION "Generated when a minor alarm is set." ::= 14 tmonMNalarmClr TRAP-TYPE ENTERPRISE tmonXM VARIABLES { tmonASite, tmonADesc, tmonAState, tmonASeverity, tmonAChgDate, tmonAChgTime, tmonAAuxDesc, tmonADispDesc, tmonAPntType, tmonAPort, tmonAAddress, tmonADisplay, tmonAPoint, tmonCEvent, tmonAIPAddr, tmonADevDesc } DESCRIPTION "Generated when a minor alarm clears." ::= 15 tmonSTalarmSet TRAP-TYPE ENTERPRISE tmonXM VARIABLES { tmonASite, tmonADesc, tmonAState, tmonASeverity, tmonAChgDate, tmonAChgTime, tmonAAuxDesc, tmonADispDesc, tmonAPntType, tmonAPort, tmonAAddress, tmonADisplay, tmonAPoint, tmonCEvent, tmonAIPAddr, tmonADevDesc } DESCRIPTION "Generated when a status alarm is set." ::= 16 tmonSTalarmClr TRAP-TYPE ENTERPRISE tmonXM VARIABLES { tmonASite, tmonADesc, tmonAState, tmonASeverity, tmonAChgDate, tmonAChgTime, tmonAAuxDesc, tmonADispDesc, tmonAPntType, tmonAPort, tmonAAddress, tmonADisplay, tmonAPoint, tmonCEvent, tmonAIPAddr, tmonADevDesc } DESCRIPTION "Generated when a status alarm clears." ::= 17 dpsRTUPointSet TRAP-TYPE ENTERPRISE dpsRTU VARIABLES { sysDescr, sysLocation, dpsRTUDateTime, dpsRTUAPort, dpsRTUAAddress, dpsRTUADisplay, dpsRTUAPoint, dpsRTUAPntDesc, dpsRTUAState } DESCRIPTION "Generated when a point is set." ::= 20 dpsRTUPointClr TRAP-TYPE ENTERPRISE dpsRTU VARIABLES { sysDescr, sysLocation, dpsRTUDateTime, dpsRTUAPort, dpsRTUCAddress, dpsRTUADisplay, dpsRTUAPoint, dpsRTUAPntDesc, dpsRTUAState } DESCRIPTION "Generated when a point clears." ::= 21 dpsRTUsumPSet TRAP-TYPE ENTERPRISE dpsRTU VARIABLES { sysDescr, sysLocation, dpsRTUDateTime } DESCRIPTION "Generated when any point is set." ::= 101 dpsRTUsumPClr TRAP-TYPE ENTERPRISE dpsRTU VARIABLES { sysDescr, sysLocation, dpsRTUDateTime } DESCRIPTION "Generated when all points clear." ::= 102 dpsRTUcomFailed TRAP-TYPE ENTERPRISE dpsRTU VARIABLES { sysDescr, sysLocation, dpsRTUDateTime } DESCRIPTION "Generated when polled unit fails to respond." ::= 103 dpsRTUcomRestored TRAP-TYPE ENTERPRISE dpsRTU VARIABLES { sysDescr, sysLocation, dpsRTUDateTime } DESCRIPTION "Generated when failed unit resumes responding." ::= 104 -- ************************************************************************** -- Granular TRAP definitions -- -- The following section supports granular trapping available on selected -- DPS remote telemetry units. This software selectable facility changes the -- trap sent by a remote so equipped. The standard trap identifies a SET or -- CLR event in the trap ID and binds variables identifying the specific -- remote point associated with the event. A granular trap identifies a SET -- or CLR event and the specific point associated with the event all in the -- trap ID. This is accomplished by mapping all SET event/points into the -- trap ID range 10001-19999 and all CLR event/points into the trap ID range -- 20001-29999. -- If the unit manages multiple displays, the displays are mapped -- sequentially with each display occupying a 64 point range. For example, a -- standalone standard or timestamp KDA which manages two displays, reports -- SET event/points in the first display (discrete alarm points) in the range -- 10001-10064. The CLR event/points for the same display would be reported -- in the range 20001-20064. The second display (controls & housekeeping -- alarm points) would have its SET event/points reported in the range 10065- -- 10128 and its CLR event/points reported in the range 20065-20128. -- SET and CLR definitions for the first 64 points have been included and -- can be used as is for driving most SNMP manager mechanisms designed to key -- on the trap ID for distinguishing and managing events. Additional events -- can be added simply by editing the following trap definitions prior to -- compiling this file into your SNMP manager. We recommend managing the SET -- and CLR event definitions for a specific point as a single unit and using -- the following simple rules: -- + Adjust the numeric portion of the label preceeding TRAP-TYPE. -- + Adjust the numeric reference in the DESCRIPTION text. -- + Adjust the number on the last line of the definition. -- -- Using these rules a definition for the 65th point would be: -- -- dpsRTUp0065Set TRAP-TYPE -- ENTERPRISE dpsRTU -- VARIABLES { sysDescr, sysLocation, dpsRTUDateTime, -- dpsRTUAPort, dpsRTUCAddress, dpsRTUADisplay, dpsRTUAPoint, -- dpsRTUAPntDesc, dpsRTUAState } -- DESCRIPTION "Generated when granular point 65 is set." -- ::= 10065 -- -- dpsRTUp0065Clr TRAP-TYPE -- ENTERPRISE dpsRTU -- VARIABLES { sysDescr, sysLocation, dpsRTUDateTime, -- dpsRTUAPort, dpsRTUCAddress, dpsRTUADisplay, dpsRTUAPoint, -- dpsRTUAPntDesc, dpsRTUAState } -- DESCRIPTION "Generated when granular point 65 clears." -- ::= 20065 -- -- This editing can can be accomplished quite easily using a plain ASCII -- file editor. The repetitive structure of the definitions also makes for -- rapid scripted or programmed generation if any such tools are available. -- A compressed file containing event/point definitions for 144 displays is -- available (DPS_G36.zip 150K) which uncompressed (DPS_G36.mib 6.2M) can be -- used for cut-and-paste editing if desired. -- The definitions can be further customized if desired by similar editing -- prior to compiling carefully observing the following conventions: -- + The label preceeding the TRAP-TYPE designator can be edited with some -- freedom but the label must be utterly unique among all trap definitions. -- + The ENTERPRISE and VARIABLES sections must not be changed. -- + The DESCRIPTION can be edited with complete freedom and is typically -- ignored within the context of standard SNMP manager trap handling. The -- quote mark before and after the text of the description are required. -- + The number on the last line of the definition is the actual trap ID -- defined and must also be utterly unique. -- -- For example: -- -- dpsRTUp0001Set TRAP-TYPE -- ENTERPRISE dpsRTU -- VARIABLES { sysDescr, sysLocation, dpsRTUDateTime, -- dpsRTUAPort, dpsRTUCAddress, dpsRTUADisplay, dpsRTUAPoint, -- dpsRTUAPntDesc, dpsRTUAState } -- DESCRIPTION "Generated when granular point 1 is set." -- ::= 10001 -- -- dpsRTUp0001Clr TRAP-TYPE -- ENTERPRISE dpsRTU -- VARIABLES { sysDescr, sysLocation, dpsRTUDateTime, -- dpsRTUAPort, dpsRTUCAddress, dpsRTUADisplay, dpsRTUAPoint, -- dpsRTUAPntDesc, dpsRTUAState } -- DESCRIPTION "Generated when granular point 1 clears." -- ::= 20001 -- -- Could be customized as: -- -- dpsRTUFireAlarm TRAP-TYPE -- ENTERPRISE dpsRTU -- VARIABLES { sysDescr, sysLocation, dpsRTUDateTime, -- dpsRTUAPort, dpsRTUCAddress, dpsRTUADisplay, dpsRTUAPoint, -- dpsRTUAPntDesc, dpsRTUAState } -- DESCRIPTION "Generated when smoke detector activates." -- ::= 10001 -- -- dpsRTUFireOut TRAP-TYPE -- ENTERPRISE dpsRTU -- VARIABLES { sysDescr, sysLocation, dpsRTUDateTime, -- dpsRTUAPort, dpsRTUCAddress, dpsRTUADisplay, dpsRTUAPoint, -- dpsRTUAPntDesc, dpsRTUAState } -- DESCRIPTION "Generated when smoke detector deactivates." -- ::= 20001 -- ************************************************************************** END