ELTEX-MES-HWENVIROMENT-MIB DEFINITIONS ::= BEGIN -- Title: Eltex MES Hardware enviroment definition -- Version: 1.3 -- Date: 27-Jul-2018 IMPORTS eltMes FROM ELTEX-MES OBJECT-TYPE FROM SNMPv2-SMI RlEnvMonState, rlEnvMonFanStatusEntry FROM RADLAN-HWENVIROMENT; eltMesEnv MODULE-IDENTITY LAST-UPDATED "201807270000Z" ORGANIZATION "Eltex Enterprise Co, Ltd." CONTACT-INFO "www.eltex.nsk.ru" DESCRIPTION "This private MIB module contains Eltex's hardware enviroment definition." REVISION "201807270000Z" DESCRIPTION "Added eltEnvResetButtonMode scalar." REVISION "201710110000Z" DESCRIPTION "Added Eltex's hardware enviroment definition." REVISION "201506110000Z" DESCRIPTION "Initial revision." ::= { eltMes 11 } -------------------------------------------------------------------------------- -- eltEnvMonBatteryStatusTable -------------------------------------------------------------------------------- eltEnvMonBatteryStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF EltEnvMonBatteryStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of battery status maintained by the environmental monitor card." ::= { eltMesEnv 1 } eltEnvMonBatteryStatusEntry OBJECT-TYPE SYNTAX EltEnvMonBatteryStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the battery status table, representing the status of the associated battery maintained by the environmental monitor." INDEX { eltEnvMonBatteryStatusIndex } ::= { eltEnvMonBatteryStatusTable 1 } EltEnvMonBatteryStatusEntry ::= SEQUENCE { eltEnvMonBatteryStatusIndex INTEGER, eltEnvMonBatteryState RlEnvMonState, eltEnvMonBatteryStatusCharge INTEGER } eltEnvMonBatteryStatusIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "Unique index for the battery being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning." ::= { eltEnvMonBatteryStatusEntry 1 } eltEnvMonBatteryState OBJECT-TYPE SYNTAX RlEnvMonState MAX-ACCESS read-only STATUS current DESCRIPTION "The mandatory state of the battery being instrumented." ::= { eltEnvMonBatteryStatusEntry 2 } eltEnvMonBatteryStatusCharge OBJECT-TYPE SYNTAX INTEGER(0..100 | 255) MAX-ACCESS read-only STATUS current DESCRIPTION "Remaining percentage of battery charge. Value of 255 means that this parameter is undefined due to battery not supporting this feature or because it cannot be obtained in current state." ::= { eltEnvMonBatteryStatusEntry 3 } -- -- eltEnvResetButtonMode -- eltEnvResetButtonMode OBJECT-TYPE SYNTAX INTEGER { enable(0), disable(1), reset-only(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Mode of reset button: 0 - Enable, 1 - disable, 2 - reset-only mode" DEFVAL { enable } ::= { eltMesEnv 2 } -- -- eltEnvMonFanStatusTable -- eltEnvMonFanStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF EltEnvMonFanStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of fan status maintained by the environmental monitor" ::= { eltMesEnv 3 } eltEnvMonFanStatusEntry OBJECT-TYPE SYNTAX EltEnvMonFanStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table augments existing RADLAN table rlEnvMonFanStatusTable" AUGMENTS { rlEnvMonFanStatusEntry } ::= { eltEnvMonFanStatusTable 1 } EltEnvMonFanStatusEntry ::= SEQUENCE { eltEnvMonFanSpeed INTEGER } eltEnvMonFanSpeed OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter represents the speed of the fan in RPM" ::= { eltEnvMonFanStatusEntry 1 } END