CT-ELS10-MIB DEFINITIONS ::= BEGIN -- SMC-MIB -- Copyright 1999 Standard Microsystems Corporation. All Rights Reserved. -- Reproduction of this document is authorized on condition that this -- copyright notice is included. This Standard Microsystems Corporation -- SNMP Management Information Base Specification (Specification) embodies -- Standard Microsystems Corporation's proprietary intellectual property. -- Standard Microsystems Corporation retains all title and ownership in -- the Specification, including any revisions. -- It is Standard Microsystems Corporation's intent to encourage the -- widespread use of this Specification in connection with the management -- of Standard Microsystems Corporation products. Standard Microsystems -- Corporation grants vendors, end-users, and other interested parties a -- non-exclusive license to use this Specification in connection with the -- management of Standard Microsystems Corporation products. -- This Specification is supplied "AS IS," and Standard Microsystems -- Corporation makes no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. IMPORTS OBJECT-TYPE FROM RFC-1212 DisplayString, sysObjectID, ifOutDiscards, ifInErrors, ifOutErrors, PhysAddress FROM RFC1213-MIB Counter, Gauge, IpAddress, TimeTicks, enterprises FROM RFC1155-SMI dot1dStpDesignatedRoot, dot1dStpRootCost, dot1dStpRootPort, dot1dStpMaxAge, dot1dStpHelloTime, dot1dStpForwardDelay, dot1dStpPortDesignatedRoot, dot1dStpPortDesignatedBridge, dot1dStpPortDesignatedCost, dot1dStpPortDesignatedPort, dot1dStpPortState FROM BRIDGE-MIB TRAP-TYPE FROM RFC-1215; -- mgmt OBJECT IDENTIFIER ::= { iso org(3) dod(6) internet(1) mgmt(2) } -- mib OBJECT IDENTIFIER ::= { mgmt 1 } -- directory OBJECT IDENTIFIER ::= { internet 1 } -- experimental OBJECT IDENTIFIER ::= { internet 3 } -- private OBJECT IDENTIFIER ::= { internet 4 } -- enterprises OBJECT IDENTIFIER ::= { private 1 } sigma OBJECT IDENTIFIER ::= { enterprises 97 } sys OBJECT IDENTIFIER ::= { sigma 1 } els10-27 OBJECT IDENTIFIER ::= { sigma 9 } els10-27hw OBJECT IDENTIFIER ::= { els10-27 1 } els10-27sw OBJECT IDENTIFIER ::= { els10-27 2 } els10-27admin OBJECT IDENTIFIER ::= { els10-27 3 } els10-27swdis OBJECT IDENTIFIER ::= { els10-27 4 } els10-27addr OBJECT IDENTIFIER ::= { els10-27 5 } els10-27if OBJECT IDENTIFIER ::= { els10-27 6 } els10-27dot3 OBJECT IDENTIFIER ::= { els10-27 7 } els10-27uart OBJECT IDENTIFIER ::= { els10-27 8 } els10-27debug OBJECT IDENTIFIER ::= { els10-27 10 } els10-27lpbk OBJECT IDENTIFIER ::= { els10-27 11 } els10-27proto OBJECT IDENTIFIER ::= { els10-27 12 } els10-27trunk OBJECT IDENTIFIER ::= { els10-27 13 } els10-27workgroup OBJECT IDENTIFIER ::= { els10-27 14 } els10-27trapMgt OBJECT IDENTIFIER ::= { els10-27 15 } els10-27pingMgt OBJECT IDENTIFIER ::= { els10-27 16 } els10-27traceMgt OBJECT IDENTIFIER ::= { els10-27 17 } els10-27volmirrorgroup OBJECT IDENTIFIER ::= { els10-27 19 } els10-27VlanBridgeConfig OBJECT IDENTIFIER ::= { els10-27 20 } els10-27volipmgroup OBJECT IDENTIFIER ::= { els10-27 21 } els10-27voligmpgroup OBJECT IDENTIFIER ::= { els10-27 22 } els10-27FlowControlCtl OBJECT IDENTIFIER ::= { els10-27 23 } -- SMC MIB -- System group sysID OBJECT-TYPE SYNTAX INTEGER { els10-27-bridge(7) } ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { sys 1 } sysReset OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { sys 2 } sysTrapPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { sys 6 } -- HW Configuration Group els10-27hwDiagCode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27hw 1 } els10-27hwManufData OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27hw 2 } els10-27hwPortCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27hw 3 } els10-27hwPortTable OBJECT-TYPE SYNTAX SEQUENCE OF LxhwPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " ::= { els10-27hw 4 } els10-27hwPortEntry OBJECT-TYPE SYNTAX LxhwPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { els10-27hwPortIndex } ::= { els10-27hwPortTable 1 } LxhwPortEntry ::= SEQUENCE { els10-27hwPortIndex INTEGER, els10-27hwPortType INTEGER, els10-27hwPortSubType INTEGER, els10-27hwPortDiagPassed INTEGER, els10-27hwAddr OCTET STRING } els10-27hwPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27hwPortEntry 1 } els10-27hwPortType OBJECT-TYPE SYNTAX INTEGER { port-csma(1), port-uart(6), port-none(255) } ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27hwPortEntry 2 } els10-27hwPortSubType OBJECT-TYPE SYNTAX INTEGER { csmacd-tpx(13), csmacd-100-tpx(16), csmacd-100-fx(17), uart-female-9pin(80), no-information(255) } ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27hwPortEntry 3 } els10-27hwPortDiagPassed OBJECT-TYPE SYNTAX INTEGER { diag-passed(1), diag-failed(2) } ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27hwPortEntry 4 } els10-27hwAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27hwPortEntry 5 } els10-27hwUpLink OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies whether the Up-Link I/O module is existed" ::= { els10-27hw 5 } els10-27hwUpLinkManufData OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This is a 32-byte array which contains the part number, serial number, and hardware revision level of the Up-Link I/O module. This array is valid only when the els10-27hwUplink is true. If els10-27hwUplink is false, it returns an error" ::= { els10-27hw 6 } -- LXSW Configuration Group els10-27swNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27sw 1 } els10-27swFilesetTable OBJECT-TYPE SYNTAX SEQUENCE OF LxswFilesetEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " ::= { els10-27sw 2 } els10-27swFilesetEntry OBJECT-TYPE SYNTAX LxswFilesetEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { els10-27swIndex } ::= { els10-27swFilesetTable 1 } LxswFilesetEntry ::= SEQUENCE { els10-27swIndex INTEGER, els10-27swDesc DisplayString, els10-27swCount INTEGER, els10-27swType OCTET STRING, els10-27swSizes OCTET STRING, els10-27swStarts OCTET STRING, els10-27swBases OCTET STRING, els10-27swFlashBank INTEGER } els10-27swIndex OBJECT-TYPE SYNTAX INTEGER { currently-executing(1), next-boot(2) } ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27swFilesetEntry 1 } els10-27swDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27swFilesetEntry 2 } els10-27swCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27swFilesetEntry 3 } els10-27swType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27swFilesetEntry 4 } els10-27swSizes OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27swFilesetEntry 5 } els10-27swStarts OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27swFilesetEntry 6 } els10-27swBases OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27swFilesetEntry 7 } els10-27swFlashBank OBJECT-TYPE SYNTAX INTEGER { first-bank(1), second-bank(2) } ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27swFilesetEntry 8 } -- LXADMIN Group els10-27adminFatalErr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Information about last reset: First byte, cause of reset, values: 00: power failure 01: WatchDog Timeout 02: Software Reset 03: NMS Shutdown 04-255: Fatal Error Second byte, Hw/Sw component that failed Remaining bytes, description of fault." ::= { els10-27admin 1 } els10-27adminAnyPass OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27admin 2 } els10-27adminGetPass OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27admin 3 } els10-27adminNMSIPAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27admin 4 } els10-27adminStorageFailure OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27admin 7 } els10-27adminAuthenticationFailure OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27admin 8 } els10-27adminNAMReceiveCongests OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27admin 10 } els10-27adminArpEntries OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27admin 11 } els10-27adminArpStatics OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27admin 12 } els10-27adminArpOverflows OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27admin 13 } els10-27adminIpEntries OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27admin 14 } els10-27adminIpStatics OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27admin 15 } els10-27adminStaticPreference OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27admin 16 } els10-27adminRipPreference OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27admin 17 } els10-27adminRipRouteDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27admin 18 } els10-27adminRebootConfig OBJECT-TYPE SYNTAX INTEGER { no-change(1), tftp-config(2), revert-to-defaults(3) } ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27admin 19 } els10-27adminDisableButton OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27admin 21 } els10-27adminButtonSelection OBJECT-TYPE SYNTAX INTEGER { led-any-activity(1), led-rx-activity(2), led-tx-activity(3), led-any-collision(4), led-programmed(5), led-duplex(6), led-speed(7), led-mirror(8) } ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27admin 22 } els10-27adminLEDProgramOption OBJECT-TYPE SYNTAX INTEGER { program-led-any-error(1) } ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27admin 23 } -- Software Distribution Group els10-27swdisDesc OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The description (0-32 bytes) of the software set currently being downloaded, or a description of the software set last downloaded since the FN1026 booted." ::= { els10-27swdis 1 } els10-27swdisAccess OBJECT-TYPE SYNTAX INTEGER { protected(1), any-software(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The version of software that may be downloaded. Attempts to download other versions of software will be rejected. The value for swdisAccess is embedded within the software files that are to be distributed via TFTP. Its value may be derived from the names of the software files. the NMS operator may wish to use the following special values: protected (1) No software downloads will be accepted any-software (2) A software download of any version of new software will be accepted - this is the factory default" ::= { els10-27swdis 2 } els10-27swdisWriteStatus OBJECT-TYPE SYNTAX INTEGER { in-progress(1), success(2), config-error(3), flash-error(4), config-and-flash-errors(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the erase/write operation." ::= { els10-27swdis 3 } els10-27swdisConfigIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the NMS (i.e., any IP host) that is allowed to use TFTP to send/retrieve the configuration file of the FN1026. A value of 0.0.0.0 (which is the factory specified default) prevents any NMS from obtaining access, while a value of 255.255.255.255 gives every NMS permission." ::= { els10-27swdis 4 } els10-27swdisConfigRetryTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds that the FN1026 will wait for an acknowledgment before it retransmits an unacknowledged TFTP data block. The factory specified default is 5 seconds." ::= { els10-27swdis 5 } els10-27swdisConfigTotalTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds that the FN1026 will wait for an acknowledgment to a data block before it cancels a TFTP session. The factory specified default is 25 seconds." ::= { els10-27swdis 6 } -- Address Configuration els10-27addrStatics OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27addr 1 } els10-27addrDynamics OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27addr 2 } els10-27addrDynamicMax OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27addr 3 } els10-27addrDynamicOverflows OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27addr 4 } els10-27addrFlags OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27addr 5 } els10-27addrMAC OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27addr 6 } els10-27addrPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27addr 7 } els10-27addrOperation OBJECT-TYPE SYNTAX INTEGER { read-random(1), read-next(2), update(4), delete(5), read-block(6) } ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27addr 8 } els10-27addrIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27addr 9 } els10-27addrNext OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27addr 10 } els10-27addrBlockSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27addr 19 } els10-27addrBlock OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27addr 20 } -- Interfaces Group els10-27ifTable OBJECT-TYPE SYNTAX SEQUENCE OF LxifEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " ::= { els10-27if 1 } els10-27ifEntry OBJECT-TYPE SYNTAX LxifEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { els10-27ifIndex } ::= { els10-27ifTable 1 } LxifEntry ::= SEQUENCE { els10-27ifIndex INTEGER, ---els10-27ifRxCnt --- INTEGER, ---els10-27ifTxCnt --- INTEGER, els10-27ifThreshold INTEGER, els10-27ifThresholdTime INTEGER, els10-27ifRxQueueThresh INTEGER, els10-27ifRxQueueThreshTime INTEGER, els10-27ifTxStormCnt INTEGER, els10-27ifTxStormTime TimeTicks, els10-27ifFunction INTEGER, els10-27ifRxHwFCSs Counter, els10-27ifRxQueues Counter, els10-27ifStatisticsTime TimeTicks, els10-27ifForwardedChars Counter, els10-27ifDescr DisplayString, els10-27ifGoodRxFrames Counter, els10-27ifGoodTxFrames Counter } els10-27ifIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27ifEntry 1 } --- els10-27ifRxCnt OBJECT-TYPE --- SYNTAX INTEGER --- ACCESS read-only --- STATUS mandatory --- DESCRIPTION --- " " --- ::= { els10-27ifEntry 2 } --- els10-27ifTxCnt OBJECT-TYPE --- SYNTAX INTEGER --- ACCESS read-only --- STATUS mandatory --- DESCRIPTION --- " " --- ::= { els10-27ifEntry 3 } els10-27ifThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27ifEntry 4 } els10-27ifThresholdTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27ifEntry 5 } els10-27ifRxQueueThresh OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27ifEntry 6 } els10-27ifRxQueueThreshTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27ifEntry 7 } els10-27ifTxStormCnt OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27ifEntry 8 } els10-27ifTxStormTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27ifEntry 9 } els10-27ifFunction OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27ifEntry 16 } els10-27ifRxHwFCSs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27ifEntry 18 } els10-27ifRxQueues OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27ifEntry 19 } els10-27ifStatisticsTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27ifEntry 27 } els10-27ifForwardedChars OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27ifEntry 28 } els10-27ifDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27ifEntry 29 } els10-27ifGoodRxFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27ifEntry 30 } els10-27ifGoodTxFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27ifEntry 31 } -- Dot3 Group els10-27dot3Table OBJECT-TYPE SYNTAX SEQUENCE OF Lxdot3Entry ACCESS not-accessible STATUS mandatory DESCRIPTION " " ::= { els10-27dot3 1 } els10-27dot3Entry OBJECT-TYPE SYNTAX Lxdot3Entry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { els10-27dot3Index } ::= { els10-27dot3Table 1 } Lxdot3Entry ::= SEQUENCE { els10-27dot3Index INTEGER, els10-27dot3TPLinkOK INTEGER, els10-27dot3LedOn INTEGER, els10-27dot3RxCollisions Counter, els10-27dot3RxRunts Counter, els10-27dot3RxLateColls Counter, els10-27dot3TxJabbers Counter, els10-27dot3TxBabbles Counter, els10-27dot3TxCollisions Counter, els10-27dot3SpeedSelection INTEGER, els10-27dot3DuplexSelection INTEGER } els10-27dot3Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27dot3Entry 1 } els10-27dot3TPLinkOK OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27dot3Entry 2 } els10-27dot3LedOn OBJECT-TYPE SYNTAX INTEGER { led-on(1), led-off(2) } ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27dot3Entry 3 } els10-27dot3RxCollisions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27dot3Entry 4 } els10-27dot3RxRunts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27dot3Entry 5 } els10-27dot3RxLateColls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27dot3Entry 6 } els10-27dot3TxJabbers OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27dot3Entry 7 } els10-27dot3TxBabbles OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27dot3Entry 8 } els10-27dot3TxCollisions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27dot3Entry 9 } els10-27dot3SpeedSelection OBJECT-TYPE SYNTAX INTEGER { speed-10mbit(1), speed-100mbit(2), speed-auto(3) } ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27dot3Entry 13 } els10-27dot3DuplexSelection OBJECT-TYPE SYNTAX INTEGER { duplex-auto(1), duplex-half(2), duplex-full(3) } ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27dot3Entry 14 } -- UART Interface Group els10-27uartTable OBJECT-TYPE SYNTAX SEQUENCE OF LxuartEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " ::= { els10-27uart 1 } els10-27uartEntry OBJECT-TYPE SYNTAX LxuartEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { els10-27uartIndex } ::= { els10-27uartTable 1 } LxuartEntry ::= SEQUENCE { els10-27uartIndex INTEGER, els10-27uartBaud INTEGER, els10-27uartAlignmentErrors Counter, els10-27uartOverrunErrors Counter } els10-27uartIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27uartEntry 1 } els10-27uartBaud OBJECT-TYPE SYNTAX INTEGER { b2400-baud(3), b4800-baud(4), b9600-baud(5), b19200-baud(6) } ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27uartEntry 2 } els10-27uartAlignmentErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27uartEntry 3 } els10-27uartOverrunErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27uartEntry 4 } -- Debug Command Group els10-27debugStringID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27debug 1 } els10-27debugString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27debug 2 } els10-27debugTable OBJECT-TYPE SYNTAX SEQUENCE OF LxdebugEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " ::= { els10-27debug 3 } els10-27debugEntry OBJECT-TYPE SYNTAX LxdebugEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { els10-27debugIndex } ::= { els10-27debugTable 1 } LxdebugEntry ::= SEQUENCE { els10-27debugIndex INTEGER, els10-27debugOperation INTEGER, els10-27debugBase INTEGER, els10-27debugLength INTEGER, els10-27debugData OCTET STRING } els10-27debugIndex OBJECT-TYPE SYNTAX INTEGER { debug-nam(1) } ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27debugEntry 1 } els10-27debugOperation OBJECT-TYPE SYNTAX INTEGER { examine(1), modify(2) } ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27debugEntry 2 } els10-27debugBase OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27debugEntry 3 } els10-27debugLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27debugEntry 4 } els10-27debugData OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27debugEntry 5 } -- Loopback Command Group els10-27lpbkTable OBJECT-TYPE SYNTAX SEQUENCE OF LxlpbkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " ::= { els10-27lpbk 1 } els10-27lpbkEntry OBJECT-TYPE SYNTAX LxlpbkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { els10-27lpbkIndex } ::= { els10-27lpbkTable 1 } LxlpbkEntry ::= SEQUENCE { els10-27lpbkIndex INTEGER, els10-27lpbkOperation INTEGER, els10-27lpbkDestAddr OCTET STRING, els10-27lpbkPktNum INTEGER, els10-27lpbkInterval TimeTicks, els10-27lpbkPktLength INTEGER, els10-27lpbkIncrements INTEGER, els10-27lpbkGoods Counter, els10-27lpbkErrorNoReceives Counter, els10-27lpbkErrorBadReceives Counter, els10-27lpbkErrorSize INTEGER, els10-27lpbkErrorSent OCTET STRING, els10-27lpbkErrorReceived OCTET STRING, els10-27lpbkErrorOffset INTEGER } els10-27lpbkIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27lpbkEntry 1 } els10-27lpbkOperation OBJECT-TYPE SYNTAX INTEGER { loopback-off(1), loopback-local(2), loopback-remote(3) } ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27lpbkEntry 2 } els10-27lpbkDestAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27lpbkEntry 3 } els10-27lpbkPktNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27lpbkEntry 4 } els10-27lpbkInterval OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27lpbkEntry 5 } els10-27lpbkPktLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27lpbkEntry 6 } els10-27lpbkIncrements OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " " ::= { els10-27lpbkEntry 7 } els10-27lpbkGoods OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27lpbkEntry 8 } els10-27lpbkErrorNoReceives OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27lpbkEntry 9 } els10-27lpbkErrorBadReceives OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27lpbkEntry 10 } els10-27lpbkErrorSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27lpbkEntry 11 } els10-27lpbkErrorSent OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27lpbkEntry 12 } els10-27lpbkErrorReceived OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27lpbkEntry 13 } els10-27lpbkErrorOffset OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { els10-27lpbkEntry 14 } -- Protocols Group els10-27protoTable OBJECT-TYPE SYNTAX SEQUENCE OF LxprotoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains configuration information specify- ing the types of protocols used to bridge, route, translate, and filter frames for each port." ::= { els10-27proto 1 } els10-27protoEntry OBJECT-TYPE SYNTAX LxprotoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry in this table specifies which protocols are used by a particular port in the ES/1." INDEX { els10-27protoIfIndex } ::= { els10-27protoTable 1 } LxprotoEntry ::= SEQUENCE { els10-27protoIfIndex INTEGER, els10-27protoBridge INTEGER, els10-27protoSuppressBpdu INTEGER, els10-27protoRipListen INTEGER, els10-27protoTrunking INTEGER, els10-27sprotoTransmitPacing INTEGER } els10-27protoIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the interface (port) to which this entry's information belongs. The value of this variable corresponds to ifIndex, as well as most of the other port identification values in related MIBs." ::= { els10-27protoEntry 1 } els10-27protoBridge OBJECT-TYPE SYNTAX INTEGER { transparent(1), none(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines the bridging method to be applied to frames received at, or destined for, this port. Ethernet and FDDI ports may be configured for transparent, srt, or none. Token Ring ports may be configured for any of the four options. The UART may only be configured to none." ::= { els10-27protoEntry 2 } els10-27protoSuppressBpdu OBJECT-TYPE SYNTAX INTEGER { normal(1), suppressed(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows transmission of spanning tree protocol packets to be suppressed. If normal(1), 802.1d spanning tree packets are transmitted as usual. If suppressed(2), these packets are not transmitted. This option may be needed for in- teroperability with non-802.1d spanning tree protocols (e.g., DEC LanBridge 100)." ::= { els10-27protoEntry 3 } els10-27protoRipListen OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether the port should listen for internet Routing Information Protocol (RFC-1058) packets, in order to build the routing table for the unit." ::= { els10-27protoEntry 4 } els10-27protoTrunking OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether SMC's trunking protocol (an extension to the standard Spanning Tree) is to be used over this port." ::= { els10-27protoEntry 5 } els10-27sprotoTransmitPacing OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled, introduces delays into normal transmission of frames, to reduce the probability of collisions during heavy traffic." ::= { els10-27protoEntry 6 } -- Trunking Group els10-27trunkTable OBJECT-TYPE SYNTAX SEQUENCE OF LxtrunkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table describes the trunking status and attributes of the interfaces that are configured for bridge trunking." ::= { els10-27trunk 1 } els10-27trunkEntry OBJECT-TYPE SYNTAX LxtrunkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry exists in this table for each physical interface (port) that is configured for trunking." INDEX { els10-27trunkIfIndex } ::= { els10-27trunkTable 1 } LxtrunkEntry ::= SEQUENCE { els10-27trunkIfIndex INTEGER, els10-27trunkState INTEGER, els10-27trunkRemoteBridgeAddr OCTET STRING, els10-27trunkRemoteIp IpAddress, els10-27trunkLastError INTEGER, els10-27trunkLinkOrdinal INTEGER, els10-27trunkLinkCount INTEGER, els10-27trunkLastChange INTEGER } els10-27trunkIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies a physical interface (port) which is configured for LAN trunking. The value of this variable corresponds to ifIndex, as well as most of the other port identification values in related MIBs." ::= { els10-27trunkEntry 1 } els10-27trunkState OBJECT-TYPE SYNTAX INTEGER { off(1), closed(2), oneway(3), joined(4), perturbed(5), helddown(6), broken(7) } ACCESS read-only STATUS mandatory DESCRIPTION "If off(1) then this link has not been enabled for trunking. If closed(2) then this link has not yet received any Trunking PDUs. If oneway(3) then incoming Trunking PDUs do not indicate that our PDUs are being successfully received by the far end. If joined(4) then this link is actively participating in the trunk group. If perturbed(5) then this link is actively participating in the trunk group; however, the transmission of data packets has been temporarily stopped due to a change in membership of the group. If helddown(6) then an error has been detected and the link is being held out-of-service until the error clears. If broken(7) then this link has been configured for trunking, but the port is physically non-operational." ::= { els10-27trunkEntry 2 } els10-27trunkRemoteBridgeAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address portion of the bridge ID of the remote bridge." ::= { els10-27trunkEntry 3 } els10-27trunkRemoteIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address of the remote bridge, as reported by that bridge for administrative purposes." ::= { els10-27trunkEntry 4 } els10-27trunkLastError OBJECT-TYPE SYNTAX INTEGER { none(1), in-bpdu(2), multiple-bridges(3), ack-lost(4), standby(5), too-many-groups(6), no-ack(7), perturbed-threshold(8), self-connect(9), port-moved(10), multiple-lan-types(11) } ACCESS read-only STATUS mandatory DESCRIPTION "The last reason for failure when the link is in closed, oneway, or helddown state." ::= { els10-27trunkEntry 5 } els10-27trunkLinkOrdinal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The position of this link within the trunk group." ::= { els10-27trunkEntry 6 } els10-27trunkLinkCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of links within the trunk group." ::= { els10-27trunkEntry 7 } els10-27trunkLastChange OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds since els10-27trunkState changed." ::= { els10-27trunkEntry 8 } -- Workgroup Group els10-27WorkGroupNextNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The next available workgroup number to be used. When creating a new workgroup, it is recommended to read the value of the variable and use it to key into the workgroup table." ::= { els10-27workgroup 1 } els10-27WorkGroupCurrentCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of workgroups currently defined." ::= { els10-27workgroup 2 } els10-27WorkGroupMaxCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of workgroups allowed." ::= { els10-27workgroup 3 } els10-27WorkGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF LxWorkGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains work group definitions for the interfaces." ::= { els10-27workgroup 4 } els10-27WorkGroupEntry OBJECT-TYPE SYNTAX LxWorkGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry in this table contains a definition of a work group." INDEX { els10-27WorkGroupNumber } ::= { els10-27WorkGroupTable 1 } LxWorkGroupEntry ::= SEQUENCE { els10-27WorkGroupNumber INTEGER, els10-27WorkGroupName DisplayString, els10-27WorkGroupPorts OCTET STRING, els10-27WorkGroupType INTEGER } els10-27WorkGroupNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "An integer that identifies the work group, used as an index to this table." ::= { els10-27WorkGroupEntry 1 } els10-27WorkGroupName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A 1-16 character work group name." ::= { els10-27WorkGroupEntry 2 } els10-27WorkGroupPorts OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A list of all ports within the group. The first octet specified ports 1-8, the second 9-16, etc." ::= { els10-27WorkGroupEntry 3 } els10-27WorkGroupType OBJECT-TYPE SYNTAX INTEGER { all(3), -- all broadcast packets invalid(4) } -- to delete this group ACCESS read-write STATUS mandatory DESCRIPTION "The type of work group: all - no additional information needs to be supplied." ::= { els10-27WorkGroupEntry 4 } -- Trap Group els10-27trapControlTable OBJECT-TYPE SYNTAX SEQUENCE OF LxtrapControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains information about the severity of each trap and whether the trap is currently enabled." ::= { els10-27trapMgt 1 } els10-27trapControlEntry OBJECT-TYPE SYNTAX LxtrapControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { els10-27trapIndex } ::= { els10-27trapControlTable 1 } LxtrapControlEntry ::= SEQUENCE { els10-27trapIndex INTEGER, els10-27trapEnabled INTEGER, els10-27trapSeverity INTEGER, els10-27trapText DisplayString } els10-27trapIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The specific trap number." ::= { els10-27trapControlEntry 1 } els10-27trapEnabled OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the generation of this trap." ::= { els10-27trapControlEntry 2 } els10-27trapSeverity OBJECT-TYPE SYNTAX INTEGER { informational(1), warning(2), minor(3), major(4), critical(5) } ACCESS read-write STATUS mandatory DESCRIPTION "A user-definable severity, indicating the importance of the trap." ::= { els10-27trapControlEntry 3 } els10-27trapText OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A description of the trap." ::= { els10-27trapControlEntry 4 } els10-27trapSeverityControlTable OBJECT-TYPE SYNTAX SEQUENCE OF LxtrapSeverityControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains information about whether a class of traps of a particular severity are enabled or disabled." ::= { els10-27trapMgt 2 } els10-27trapSeverityControlEntry OBJECT-TYPE SYNTAX LxtrapSeverityControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { els10-27trapSeverity } ::= { els10-27trapSeverityControlTable 1 } LxtrapSeverityControlEntry ::= SEQUENCE { els10-27trapSeverityControlSeverity INTEGER, els10-27trapSeverityEnable INTEGER } els10-27trapSeverityControlSeverity OBJECT-TYPE SYNTAX INTEGER { informational(1), warning(2), minor(3), major(4), critical(5) } ACCESS read-write STATUS mandatory DESCRIPTION "A user-definable severity, indicating the importance of the trap." ::= { els10-27trapSeverityControlEntry 1 } els10-27trapSeverityEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable all traps of a given severity level." ::= { els10-27trapSeverityControlEntry 2 } els10-27trapIncludeText OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Whether or not a formatted text string is included in the trap PDU." ::= { els10-27trapMgt 3 } els10-27trapTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "The time, in centiseconds, which should expire between the sending of traps." -- DEFVAL { 100 } ::= { els10-27trapMgt 4 } els10-27trapRetry OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of times any enterprise-specific trap is to be sent for a given event. PDUs are retried using a truncated exponential backoff: 2 seconds, 4 seoncs, 8 seconds, 16 seconds, and then 32 seconds for all succeeding intervals." -- DEFVAL { 1 } ::= { els10-27trapMgt 5 } els10-27trapNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of traps that are in the els10-27trapTable." ::= { els10-27trapMgt 6 } els10-27trapTable OBJECT-TYPE SYNTAX SEQUENCE OF LxtrapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the latest traps that have been generated." ::= { els10-27trapMgt 7 } els10-27trapEntry OBJECT-TYPE SYNTAX LxtrapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { els10-27trapEntryIndex } ::= { els10-27trapTable 1 } LxtrapEntry ::= SEQUENCE { els10-27trapEntryIndex INTEGER, els10-27trapEntryTimeStamp TimeTicks, els10-27trapEntryText DisplayString, els10-27trapEntryNumber INTEGER, els10-27trapEntrySeverity INTEGER } els10-27trapEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A number representing the order in which the trap occurred in time. This 32 bit number can wrap." ::= { els10-27trapEntry 1 } els10-27trapEntryTimeStamp OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time at which the trap occurred." ::= { els10-27trapEntry 2 } els10-27trapEntryText OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A description of the trap." ::= { els10-27trapEntry 3 } els10-27trapEntryNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The specific trap number, as specified in the TRAP PDU." ::= { els10-27trapEntry 4 } els10-27trapEntrySeverity OBJECT-TYPE SYNTAX INTEGER { informational(1), warning(2), minor(3), major(4), critical(5) } ACCESS read-only STATUS mandatory DESCRIPTION "A user-definable severity, indicating the importance of the trap." ::= { els10-27trapEntry 5 } -- Ping Management MIB els10-27pingDataTimeout OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "The time, in centiseconds, from the last ping activity (a send or receive of an ECHO_RESPONSE or ECHO_REQUEST message), to when the els10-27pingEntry information for that ping request will be deleted." ::= {els10-27pingMgt 1} els10-27pingTable OBJECT-TYPE SYNTAX SEQUENCE OF LxpingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The set of information describing the active ping requests and their results." ::= {els10-27pingMgt 2} els10-27pingEntry OBJECT-TYPE SYNTAX LxpingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The parameters, state, and results of a ping request." INDEX { els10-27pingNMSAddr,els10-27pingDestAddr } ::= {els10-27pingTable 1} LxpingEntry ::= SEQUENCE { els10-27pingNMSAddr IpAddress, els10-27pingDestAddr IpAddress, els10-27pingState INTEGER, els10-27pingCount INTEGER, els10-27pingDataSize INTEGER, els10-27pingWait TimeTicks, els10-27pingTimeOut TimeTicks, els10-27pingOperation INTEGER, els10-27pingMin TimeTicks, els10-27pingMax TimeTicks, els10-27pingAvg TimeTicks, els10-27pingNumTransmitted INTEGER, els10-27pingNumReceived INTEGER } els10-27pingNMSAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address of the NMS, used to determine which ping request to return information on." ::= {els10-27pingEntry 1} els10-27pingDestAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address which is to be the destination of the ping ECHO_REQUEST. This variable cannot be set while els10-27pingOperation is on." ::= {els10-27pingEntry 2} els10-27pingState OBJECT-TYPE SYNTAX INTEGER { not-started(0), active (1), timed-out (2), completed (3)} ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the ping request. " ::= {els10-27pingEntry 3} els10-27pingCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of ping requests which are to be sent. This variable cannot be set while els10-27pingOperation is on." ::= { els10-27pingEntry 4} els10-27pingDataSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The datagram packet size which will be sent with the ECHO_REQUEST, in bytes. This variable cannot be set while els10-27pingOperation is on." ::= { els10-27pingEntry 5} els10-27pingWait OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "The time, in centiseconds, between the sending of each ECHO_REQUEST message. This variable cannot be set while els10-27pingOperation is on." ::= { els10-27pingEntry 6} els10-27pingTimeOut OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "The time, in centiseconds, since the last ECHO_RESPONSE was received (or the last ECHO_REQUEST was sent, if there have been no responses) when the ping request will time out. This variable cannot be set while els10-27pingOperation is on." ::= {els10-27pingEntry 7} els10-27pingOperation OBJECT-TYPE SYNTAX INTEGER {on (1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting els10-27pingOperation to on will begin the ping request. Setting els10-27pingOperation to off will terminate the ping request." ::= {els10-27pingEntry 8} els10-27pingMin OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The minimum round trip time for the ping requests and responses, in centiseconds." ::= {els10-27pingEntry 9} els10-27pingMax OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The maximum round trip for the ping requests and responses, in centiseconds." ::= {els10-27pingEntry 10} els10-27pingAvg OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The average round trip time for the ping requests and responses, in centiseconds." ::= {els10-27pingEntry 11} els10-27pingNumTransmitted OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP ECHO_REQUEST messages that have been transmitted during this ping request." ::= {els10-27pingEntry 12} els10-27pingNumReceived OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of ICMP ECHO_RESPONSE messages that have been received as a result of this ping request." ::= {els10-27pingEntry 13} -- Traceroute Management els10-27traceDataTimeout OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "The time, in centiseconds, from the last traceroute activity (the response to or timeout of the last probe sent), to when the els10-27traceEntry information for that traceroute request will be deleted." ::= {els10-27traceMgt 1} els10-27traceTable OBJECT-TYPE SYNTAX SEQUENCE OF LxtraceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The set of information describing the active traceroute requests and their results." ::= {els10-27traceMgt 2} els10-27traceEntry OBJECT-TYPE SYNTAX LxtraceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The parameters, state, and results of a traceroute request." INDEX { els10-27traceNMSAddr, els10-27traceDestAddr, els10-27traceHop, els10-27traceProbe} ::= {els10-27traceTable 1} LxtraceEntry ::= SEQUENCE { els10-27traceNMSAddr IpAddress, els10-27traceDestAddr IpAddress, els10-27traceMaxTTL INTEGER, els10-27traceDataSize INTEGER, els10-27traceNumProbes INTEGER, els10-27traceWait TimeTicks, els10-27traceOperation INTEGER, els10-27traceHop INTEGER, els10-27traceHopAddr IpAddress, els10-27traceProbe INTEGER, els10-27traceState INTEGER, els10-27traceTime TimeTicks } els10-27traceNMSAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address of the NMS, used to determine which traceroute request to return information on." ::= {els10-27traceEntry 1} els10-27traceDestAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address which is to be the destination of the traceroute request.This variable cannot be set while els10-27traceOperation is on." ::= {els10-27traceEntry 2} els10-27traceMaxTTL OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum time-to-live for outgoing traceroute probe packets. This determines the number of hops that can be in a traceroute. This variable cannot be set while els10-27traceOperation is on." ::= {els10-27traceEntry 3} els10-27traceDataSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The size of the datagram sent with each probe. This variable cannot be set while els10-27traceOperation is on." ::= {els10-27traceEntry 4} els10-27traceNumProbes OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of probes which are sent for each hop. This variable cannot be set while els10-27traceOperation is on." ::= {els10-27traceEntry 5} els10-27traceWait OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "The time to wait in response to a probe. This variable cannot be set while els10-27traceOperation is on." ::= {els10-27traceEntry 6} els10-27traceOperation OBJECT-TYPE SYNTAX INTEGER {on (1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting els10-27traceOperation to on will begin the traceroute request. Setting els10-27traceOperation to off will terminate the traceroute request." ::= {els10-27traceEntry 7} els10-27traceHop OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The hop count for a set of probes with a particular TTL." ::= {els10-27traceEntry 8} els10-27traceHopAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address of the host which responded for a probe with a particular TTL." ::= {els10-27traceEntry 9} els10-27traceProbe OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The probe instance for a particular hop." ::= {els10-27traceEntry 10} els10-27traceState OBJECT-TYPE SYNTAX INTEGER { not-started(0), active (1), time-exceeded(2), host-unreachable (3), net-unreachable (4), completed (5)} ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the trace probe." ::= {els10-27traceEntry 11} els10-27traceTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Round trip time of a probe for a particular hop." ::= {els10-27traceEntry 12} -- Enterprise Specific Objects for Port Mirroring els10-27volmirrorMode OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-write STATUS mandatory DESCRIPTION " To turn port mirroring on or off." ::= { els10-27volmirrorgroup 1 } els10-27volmirrorPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The number of the port whose data will be mirrored to a special monitor or analyzer port." ::= { els10-27volmirrorgroup 2 } els10-27volmonitorPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " Identifies the monitor or analyzer port to receive frames from the special mirror port." ::= { els10-27volmirrorgroup 3 } els10-27volMirrorMacTable OBJECT-TYPE SYNTAX SEQUENCE OF Els10-27volMirrorMacEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table that contains information for the mirroring on MAC addresses." ::= { els10-27volmirrorgroup 4 } els10-27volmirrorMacEntry OBJECT-TYPE SYNTAX Els10-27volMirrorMacEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Information about specific unicast MAC addresses for which mirroring will act upon." INDEX {els10-27volmirrorIndex} ::= { els10-27volMirrorMacTable 1 } Els10-27volMirrorMacEntry ::= SEQUENCE { els10-27volmirrorIndex INTEGER, els10-27volmirrorMac1 OCTET STRING -- els10-27volmirrorMac2 -- OCTET STRING, -- els10-27volmirrorMac3 -- OCTET STRING, -- els10-27volmirrorMac4 -- OCTET STRING } els10-27volmirrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " Entry Index" ::= {els10-27volmirrorMacEntry 1} els10-27volmirrorMac1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " First MAC address for mirroring." ::= {els10-27volmirrorMacEntry 2} --els10-27volmirrorMac2 OBJECT-TYPE -- SYNTAX OCTET STRING -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- " Second MAC address for mirroring." -- ::= {els10-27volMirrorMacEntry 2} --els10-27volmirrorMac3 OBJECT-TYPE -- SYNTAX OCTET STRING -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- " Third MAC address for mirroring." -- ::= {els10-27volMirrorMacEntry 3} --els10-27volmirrorMac4 OBJECT-TYPE -- SYNTAX OCTET STRING -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- " Fourth MAC address for mirroring." -- ::= {els10-27volMirrorMacEntry 4} -- The els10-27VlanBridgeConfig group manages the overall configuration -- of the bridge's VLAN resources. -- -- The implementation of this group is MANDATORY. els10-27VlanVersionNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the version IEEE 802.1Q VLAN that has been implemented to." ::= { els10-27VlanBridgeConfig 1 } els10-27VlanOperatingMode OBJECT-TYPE SYNTAX INTEGER { ieee8021d(1), ieee8021Q(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects the mode of operation. The switch can operate as simply an 802.1d switch, or an 802.1d switch with IEEE VLAN capability (802.1Q). A read of this object will return the current operating mode." DEFVAL { ieee8021d } ::= { els10-27VlanBridgeConfig 2 } els10-27VlanResetDefaults OBJECT-TYPE SYNTAX INTEGER { operating(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To reset the specified bridge. The filtering database is cleared and initialized with the entries specified in the Permananent database, and the Bridge protocol Entity is initialized. While initializing a read will return a value of reset (2). While operational a read will return a value of operating (2)." ::= { els10-27VlanBridgeConfig 3 } els10-27VlanGVRPEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If the switch is operating in 802.1Q mode, this selects whether GVRP protocol messages should be processed and VLANs configured accordingly for each port on the switch. Each octet within the value of this object specifies a set of eight ports, with the first octet specifying ports 1 through 8, the next octet specifying ports 9 through 16, etc. Within each octet, the least significant bit represents the lowest numbered port, and the most significant bit represents the highest numbered port. Thus, each port of the VLAN bridge is represented by single bit within the value of this object. If that bit has a value of '1' then that port is included in the set of ports; the port is not included if its bit has a value of '0'" DEFVAL { disabled } ::= { els10-27VlanBridgeConfig 4 } els10-27VlanAccessList OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A list of ports that should act as 'Access Ports'. These ports will strip all tags on egress and also make use of a shared database that will automatically be kept by the firmware. Each octet within the value of this object specifies a set of eight ports, with the first octet specifying ports 1 through 8, the next octet specifying ports 9 through 16, etc. Within each octet, the least significant bit represents the lowest numbered port, and the most significant bit represents the highest numbered port. Thus, each port of the VLAN bridge is represented by single bit within the value of this object. If that bit has a value of '1' then that port is included in the set of ports; the port is not included if its bit has a value of '0'" ::= { els10-27VlanBridgeConfig 5 } els10-27VlanConfigVlan OBJECT IDENTIFIER ::= { els10-27VlanBridgeConfig 6 } -- The els10-27VlanConfigVlan manages the configuration of a specific -- VLAN within a bridge. -- Each VLAN will have an entry in the els10-27VlanConfigTable -- -- The implementation of this group is MANDATORY. els10-27VlanNumActiveEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of active VLAN entries for the device. This includes both static and dynamic VLANs." ::= { els10-27VlanConfigVlan 1 } els10-27VlanNumConfiguredEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of configured VLAN entries for the device." ::= { els10-27VlanConfigVlan 2 } els10-27VlanMaxNumEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of VLAN entries for the device." ::= { els10-27VlanConfigVlan 3 } els10-27VlanConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Els10-27VlanConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table allows for the creation, deletion, and modification of specific VLANs. The ports defined within this group will be members of the 'member set' as defined in the IEEE 802.1Q specification." ::= { els10-27VlanConfigVlan 4 } els10-27VlanConfigEntry OBJECT-TYPE SYNTAX Els10-27VlanConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Allows for configuration of specific VLAN entries." INDEX { els10-27VlanConfigVID } ::= { els10-27VlanConfigTable 1 } Els10-27VlanConfigEntry ::= SEQUENCE { els10-27VlanConfigIndex INTEGER, els10-27VlanConfigVID INTEGER, els10-27VlanConfigPorts INTEGER, els10-27VlanConfigIP INTEGER, els10-27VlanConfigIPMask INTEGER, els10-27VlanConfigName DisplayString, els10-27VlanConfigStatus INTEGER, els10-27VlanConfigEstablish INTEGER } els10-27VlanConfigIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The interface being configured." ::= { els10-27VlanConfigEntry 1 } els10-27VlanConfigVID OBJECT-TYPE SYNTAX INTEGER (1..4094) ACCESS read-write STATUS mandatory DESCRIPTION "The 12 bit VLAN Identifier associated with the configured VLAN." ::= { els10-27VlanConfigEntry 2 } els10-27VlanConfigPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " Each octet within the value of this object specifies a set of eight ports, with the first octet specifying ports 1 through 8, the next octet specifying ports 9 through 16, etc. Within each octet, the least significant bit represents the lowest numbered port, and the most significant bit represents the highest numbered port. Thus, each port of the VLAN bridge is represented by single bit within the value of this object. If that bit has a value of '1' then that port is included in the set of ports; the port is not included if its bit has a value of '0'." ::= { els10-27VlanConfigEntry 3 } els10-27VlanConfigIP OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The IP address to be used to access the unit on this Vlan. This must be a valid host address." ::= { els10-27VlanConfigEntry 4 } els10-27VlanConfigIPMask OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The IP subnet mask to be used with this Ip address." ::= { els10-27VlanConfigEntry 5 } els10-27VlanConfigName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..32)) ACCESS read-write STATUS mandatory DESCRIPTION "The ASCII name associated with the configured VLAN. A set of this object prior to creating an entry by setting els10-27VlanEstablish will fail with a NO-INSTANCE error." ::= { els10-27VlanConfigEntry 6 } els10-27VlanConfigStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "A set with the value of enable(1), enables all associated entries in els10-27VlanConfigVID table for the specified VLAN. A set of disable(2), disables all els10-27VlanConfigVID entries associated with the specified VLAN. A set of this object prior to creating an entry by setting els10-27VlanConfigEstablish will fail with a NO-INSTANCE error." DEFVAL { disable } ::= { els10-27VlanConfigEntry 7 } els10-27VlanConfigEstablish OBJECT-TYPE SYNTAX INTEGER { create(1), delete(2) } ACCESS read-write STATUS mandatory DESCRIPTION "A set of the value create(1), causes an entry to be created in the els10-27VlanConfigTable as specified by the instancing information of els10-27VlanConfigVID, els10-27VlanConfigName, and els10-27VlanConfigPorts. A set of delete(2) causes the specified entry to be removed from the table. A read of this object will always return create(1)." ::= { els10-27VlanConfigEntry 8 } els10-27VlanConfigEgressTable OBJECT-TYPE SYNTAX SEQUENCE OF Els10-27VlanConfigEgressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table allows for the specifying of the default VLAN ID for a specific port. If NOT configured as an 'Access' port, then packets containing this VLAN ID will have the tag stripped on egress. This will set the PVID for each port contained within the list." ::= { els10-27VlanConfigVlan 5 } els10-27VlanConfigEgressEntry OBJECT-TYPE SYNTAX Els10-27VlanConfigEgressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Allows for configuration of specific VLAN entries." INDEX { els10-27VlanEgressVID } ::= { els10-27VlanConfigEgressTable 1 } Els10-27VlanConfigEgressEntry ::= SEQUENCE { els10-27VlanEgressIndex INTEGER, els10-27VlanEgressVID INTEGER, els10-27VlanEgressList INTEGER, els10-27VlanEgressStatus INTEGER } els10-27VlanEgressIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The index into the Vlan table. A port must be a member of this Vlan prior to assigning this Id as the default. " ::= { els10-27VlanConfigEgressEntry 1 } els10-27VlanEgressVID OBJECT-TYPE SYNTAX INTEGER (1..4094) ACCESS read-write STATUS mandatory DESCRIPTION "The 12 bit VLAN Identifier associated with the configured VLAN." ::= { els10-27VlanConfigEgressEntry 2 } els10-27VlanEgressList OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The set of ports to which traffic destined for the VLAN specified by els10-27VlanEgressVID on the device will have this tag stripped on egress. Each octet within the value of this object specifies a set of eight ports, with thee first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the least significant bit represents the lowest numbered port, and the most significant bit represents the highest numbered port. Thus, each port of the VLAN bridge is represented by a single bit within the value of this object. If that bit has a value of '1' then that port is included in the set of ports; the port is not included if its bit has a value of '0'." ::= { els10-27VlanConfigEgressEntry 3 } els10-27VlanEgressStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "A set with the value of enable(1), enables all associated entries in els10-27VlanEgressVID table for the specified VLAN. A set of disable(2), disables all els10-27VlanEgressVID entries associated with the specified VLAN. A set of this object prior to creating an entry by setting els10-27VlanEgressEstablish will fail with a NO-INSTANCE error." DEFVAL { disable } ::= { els10-27VlanConfigEgressEntry 4 } els10-27VlanFilterGVRPTable OBJECT-TYPE SYNTAX SEQUENCE OF Els10-27VlanFilterGVRPEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table allows for the specifying of VLAN ID's that will be resticted from being learnt by the device. If a GVRP packet is received specifying this VLAN ID, it will be ignored." ::= { els10-27VlanConfigVlan 6 } els10-27VlanFilterGVRPEntry OBJECT-TYPE SYNTAX Els10-27VlanFilterGVRPEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Allows for configuration of specific entries." INDEX { els10-27VlanFilterGVRPVID } ::= { els10-27VlanFilterGVRPTable 1 } Els10-27VlanFilterGVRPEntry ::= SEQUENCE { els10-27VlanFilterGVRPIndex INTEGER, els10-27VlanFilterGVRPVID INTEGER, els10-27VlanFilterGVRPList INTEGER, els10-27VlanFilterGVRPStatus INTEGER, els10-27VlanFilterGVRPEstablishVID INTEGER } els10-27VlanFilterGVRPIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The index into the Vlan Filter table. A maximum of 32 Vlan ID can be restricted from being learnt via GVRP. " ::= { els10-27VlanFilterGVRPEntry 1 } els10-27VlanFilterGVRPVID OBJECT-TYPE SYNTAX INTEGER (1..4094) ACCESS read-write STATUS mandatory DESCRIPTION "The 12 bit VLAN Identifier associated with the configured VLAN." ::= { els10-27VlanFilterGVRPEntry 2 } els10-27VlanFilterGVRPList OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The set of ports that will be restricted from leaning of a VLAN ID from a GVRP message. The VLAN ID is specified by els10-27VlanFilterGVRPVID. Each octet within the value of this object specifies a set of eight ports, with thee first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the least significant bit represents the lowest numbered port, and the most significant bit represents the highest numbered port. Thus, each port of the VLAN bridge is represented by a single bit within the value of this object. If that bit has a value of '1' then that port is included in the set of ports; the port is not included if its bit has a value of '0'." ::= { els10-27VlanFilterGVRPEntry 3 } els10-27VlanFilterGVRPStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "A set with the value of enable(1), enables all associated entries in els10-27VlanFilterGVRPVID table for the specified VLAN. A set of disable(2), disables all els10-27VlanFilterGVRPVID entries associated with the specified VLAN. A set of this object prior to creating an entry by setting els10-27VlanConfigEstablish will fail with a NO-INSTANCE error." DEFVAL { disable } ::= { els10-27VlanFilterGVRPEntry 4 } els10-27VlanFilterGVRPEstablishVID OBJECT-TYPE SYNTAX INTEGER { create(1), delete(2) } ACCESS read-write STATUS mandatory DESCRIPTION "A set of the value create(1), causes an entry to be created in the els10-27VlanFilterGVRPTable as specified by the instancing information of els10-27VlanFilterGVRpVID, and els10-27VlanFilterGVRPPorts. A set of delete(2) causes the specified entry to be removed from the table. A read of this object will always return create(1)." ::= { els10-27VlanFilterGVRPEntry 5 } els10-27VlanStaticTable OBJECT-TYPE SYNTAX SEQUENCE OF Els10-27VlanStaticEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Allows for configuration of specific VLAN/MAC Address entries and to specify the port to which traffic destined for this address pair should be forwarded. These entries will not be aged out of the forwarding data base." ::= { els10-27VlanConfigVlan 7 } els10-27VlanStaticEntry OBJECT-TYPE SYNTAX Els10-27VlanStaticEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Allows for specifying specific entries." INDEX { els10-27VlanStaticVID } ::= { els10-27VlanStaticTable 1 } Els10-27VlanStaticEntry ::= SEQUENCE { els10-27VlanStaticVID INTEGER, els10-27VlanStaticMAC PhysAddress, els10-27VlanStaticPort INTEGER, els10-27VlanStaticEstablish INTEGER } els10-27VlanStaticVID OBJECT-TYPE SYNTAX INTEGER (1..4094) ACCESS read-write STATUS mandatory DESCRIPTION "The 12 bit VLAN Identifier associated with the configured VLAN." ::= { els10-27VlanStaticEntry 1 } els10-27VlanStaticMAC OBJECT-TYPE SYNTAX PhysAddress ACCESS read-write STATUS mandatory DESCRIPTION "The media dependent physical address." ::= { els10-27VlanStaticEntry 2 } els10-27VlanStaticPort OBJECT-TYPE SYNTAX INTEGER (1.. 27) ACCESS read-write STATUS mandatory DESCRIPTION "An integer designating the port number to associate this address to." ::= { els10-27VlanStaticEntry 3 } els10-27VlanStaticEstablish OBJECT-TYPE SYNTAX INTEGER { create(1), delete(2) } ACCESS read-write STATUS mandatory DESCRIPTION "A set of the value create(1), causes an entry to be created as specified by the instancing information of els10-27VlanSaticVID, els10-27VlanStaticMAC, and els10-27VlanStaticPorts. A set of delete(2) causes the specified entry to be removed from thetable. A read of this object will always return create(1)." ::= { els10-27VlanStaticEntry 4 } -- the IP Multicast group els10-27IPMulticastStatus OBJECT-TYPE SYNTAX INTEGER {enabled (1), disabled (0)} ACCESS read-write STATUS mandatory DESCRIPTION " Parameter to enable or disable IP multicast filtering on the device. When enabled, the device will examine IP Multicast data packets and dynamically set up filter ports to prevent flooding. The default is disabled." ::= {els10-27volipmgroup 1} els10-27ipmInterfaceRtr OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Parameter to enable or disable the inclusion of this interface in all Multicast filters. When enabled, all IP Multicast packets for all group filters will be transmitted over this interface. Value is a bit mask." ::= {els10-27volipmgroup 2} -- the IGMP group els10-27igmpStatus OBJECT-TYPE SYNTAX INTEGER {enabled (0), disabled (1) } ACCESS read-write STATUS mandatory DESCRIPTION "Parameter to enable or disable IGMP snooping on the device. When enabled, the device will examine IGMP packets and set up filters for IGMP ports. The default is enabled." ::= {els10-27voligmpgroup 1} els10-27igmpQueryStatus OBJECT-TYPE SYNTAX INTEGER {enabled (1), disabled (0) } ACCESS read-write STATUS mandatory DESCRIPTION "Parameter to enable or disable the device to act as a Querier. If enabled, the device will send out a Query as a Proxy to solicit reports. The device will not become an IGMP router. The default is disabled." ::= {els10-27voligmpgroup 2} els10-27igmpQueryCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Maximum number of queries that have not been heard on the system before the system starts taking action to solicit reports (default is 5)." ::= {els10-27voligmpgroup 3} els10-27igmpPortDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Timeout value (mins) between IGMP Reports or IGMP Queries received on a port before the system times out the entry from the Multicast Address Filter (default is 5 minutes)." ::= {els10-27voligmpgroup 4} -- The IGMP Cache Table els10-27igmpCacheTable OBJECT-TYPE SYNTAX SEQUENCE OF Els10-27igmpCacheEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The (conceptual) table listing the IP multicast groups for which there are members on a particular interface." ::={els10-27voligmpgroup 5} els10-27igmpCacheEntry OBJECT-TYPE SYNTAX Els10-27igmpCacheEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry (conceptual row) in the els10-27igmpCacheTable." INDEX {els10-27igmpCacheAddress,els10-27igmpCacheIfIndex} ::={els10-27igmpCacheTable 1} Els10-27igmpCacheEntry ::= SEQUENCE { els10-27igmpCacheAddress IpAddress, els10-27igmpCacheIfIndex INTEGER, els10-27igmpCacheExpiryTime TimeTicks } els10-27igmpCacheAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP multicast group address for which this entry contains information." ::={els10-27igmpCacheEntry 1} els10-27igmpCacheIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The interface for which this entry contains infor- mation for an IP multicast group address." ::={els10-27igmpCacheEntry 2} els10-27igmpCacheExpiryTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The minimum amount of time remaining before this entry will be aged out." ::={els10-27igmpCacheEntry 3} -- The els10-27FlowControl MIB is used to manage Volcano devices. -- This managed object will allow for control and statistics -- on half duplex flow control (back pressure) ports and IEEE 802.3x full -- duplex flow control ports. els10-27FlowControlBackPressure OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Control back pressure on a system wide basis. On (1), Off (2)" ::= { els10-27FlowControlCtl 1 } els10-27FlowControlThresholdValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " A value specified as a percent of the available buffers. When fewer than the percent of the avaialable buffers is detected, flow control will be initiated. Flow control will cease when the free buffer count meets or exceeds this percent." ::= { els10-27FlowControlCtl 2 } els10-27FlowControlPauseInteval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A value between 10 and 65535. Each pause interval is equal to '5.12 microseconds'. A value of 10 will equal '51.2 microseconds'." ::= { els10-27FlowControlCtl 3 } els10-27FlowControlTable OBJECT-TYPE SYNTAX SEQUENCE OF Els10-27FlowControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Provides a list of control objects over flow control parameters." ::= { els10-27FlowControlCtl 4 } els10-27FlowControlEntry OBJECT-TYPE SYNTAX Els10-27FlowControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Defines a particular entry containing objects pertaining to definition and control over flow control ports." INDEX { els10-27FlowControlInterface} ::= { els10-27FlowControlTable 1 } Els10-27FlowControlEntry ::= SEQUENCE { els10-27FlowControlInterface INTEGER, els10-27FlowControlEnable INTEGER, els10-27FlowControlRxPauseFrames INTEGER, els10-27FlowControlTxPauseFrames INTEGER } els10-27FlowControlInterface OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The MIB2 interface for which this flow control information pertains" ::= { els10-27FlowControlEntry 1 } els10-27FlowControlEnable OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " Control 802.3x flow control on a per interface basis. On (1), Off (2)" ::= { els10-27FlowControlEntry 2 } els10-27FlowControlRxPauseFrames OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of pause frames received on this interface." ::= { els10-27FlowControlEntry 3 } els10-27FlowControlTxPauseFrames OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of pause frames transmitted on this interface." ::= { els10-27FlowControlEntry 4 } -- Enterprise Specific Traps for the ELS10-27 els10-27WriteStatusTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, els10-27swdisWriteStatus, els10-27swdisDesc } DESCRIPTION "Sent when a bank of Flash EPROM has been erased. If els10-27swdisWriteStatus indicates success, then the unit is ready to be downloaded with the new software." ::= 2 els10-27PortFunctionsTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, els10-27ifFunction } DESCRIPTION "Sent whenever the current functional state (active protocols) of the port has changed." ::= 3 els10-27RxQueuesTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, els10-27ifRxQueues } DESCRIPTION "Sent whenever the number of times that the port's receiver has stopped receiving packets due to buffer space shortages has exceeded the port's limit." ::= 4 els10-27RxStormFlagTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity } DESCRIPTION "Sent whenever broadcast/multicast storm protection has been invoked for the port." ::= 5 els10-27TxCongestsTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, els10-27adminNAMReceiveCongests } DESCRIPTION "Sent whenever packets destined for the unit itself were discarded due to lack of buffer space." ::= 6 els10-27DebugStringIdTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, els10-27debugStringID, els10-27debugString } DESCRIPTION "Sent whenever the unit has a debug text string to be displayed. The text strings are sent in a stream-like fashion." ::= 8 els10-27LpbkOperationTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, els10-27lpbkOperation, els10-27lpbkErrorNoReceives, els10-27lpbkErrorBadReceives } DESCRIPTION "Send whenever the unit has finished a loop back test, or a loop back error has been detected." ::= 9 els10-27TrunkStateTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, els10-27trunkState } DESCRIPTION "A trunking state change transition has occurred. The possible transitions are: CLOSED-ONEWAY ONEWAY-PERTURBED PERTURBED-JOINED JOINED-HELDDOWN CLOSED-HELDDOWN ONEWAY-HELDDOWN PERTURBED-HELDDOWN" ::= 10 els10-27TrunkBridgeAddrTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, els10-27trunkRemoteBridgeAddr } DESCRIPTION "The associated trunking MAC address of the bridge ID of the remote bridge has changed." ::= 11 els10-27TrunkIPAddrTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, els10-27trunkRemoteIp } DESCRIPTION "The associated trunking IP address of the remote bridge has changed." ::= 12 els10-27TrunkErrorTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, els10-27trunkLastError } DESCRIPTION "An error has occurred in trunking." ::= 13 els10-27TrunkLinkOrdinalTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, els10-27trunkLinkOrdinal } DESCRIPTION "The port's index in the trunking group has changed." ::= 14 els10-27TrunkLinkCountTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, els10-27trunkLinkCount } DESCRIPTION "The number of ports in the trunking group has changed." ::= 15 els10-27DiagUnitBootedTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, els10-27adminFatalErr } DESCRIPTION "The unit has booted. els10-27adminFatalErr contains information about why the unit rebooted." ::= 16 els10-27StorageFailureTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity } DESCRIPTION "Sent if the unit's Configuration EEPROM has failed. The unit will not be able to reboot, and must be returned to the factory." ::= 17 els10-27PortCongestedTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, ifOutDiscards } DESCRIPTION "Sent whenever outbound congestion control has been invoked for the port." ::= 18 els10-27TopChangeBegunTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity } DESCRIPTION "The spanning tree topology has begun to change." ::= 19 els10-27TopChangeEndTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity } DESCRIPTION "The spanning tree topology has stopped changing." ::= 20 els10-27IfErrorsTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, ifInErrors, ifOutErrors } DESCRIPTION "Sent whenever the number of hardware errors in received and transmitted packets has exceeded the port's limit." ::= 21 els10-27StRootIDTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, dot1dStpDesignatedRoot } DESCRIPTION "The spanning tree root bridge ID for the unit has changed." ::= 22 els10-27StRootCostTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, dot1dStpRootCost } DESCRIPTION "The unit's spanning tree cost to the root bridge has changed." ::= 23 els10-27StRootPortTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, dot1dStpRootPort } DESCRIPTION "The unit's spanning tree root port has changed." ::= 24 els10-27StMaxAgeTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, dot1dStpMaxAge } DESCRIPTION "The unit's spanning tree maximum age has changed." ::= 25 els10-27StHelloTimeTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, dot1dStpHelloTime } DESCRIPTION "The unit's spanning tree hello time has changed." ::= 26 els10-27StForwardDelayTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, dot1dStpForwardDelay } DESCRIPTION "The unit's spanning tree forward delay time has changed." ::= 27 els10-27StDesigRootTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, dot1dStpPortDesignatedRoot } DESCRIPTION "The Root Bridge ID in received Spanning Tree Configuration BPDUs from the port has changed." ::= 28 els10-27StPortDesigBridgeTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, dot1dStpPortDesignatedBridge } DESCRIPTION "The bridge ID of the spanning tree designated bridge of the LAN/WAN to which the port is attached has changed." ::= 29 els10-27StPortDesigCostTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, dot1dStpPortDesignatedCost } DESCRIPTION "The cost to the spanning tree root bridge from the designated port of the LAN/WAN to which the port is attached has changed." ::= 30 els10-27StPortDesigPortTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, dot1dStpPortDesignatedPort } DESCRIPTION "The port ID of the spanning tree designated port of the LAN/WAN to which the port is attached has changed." ::= 31 els10-27StPortStateTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, dot1dStpPortState } DESCRIPTION "The spanning tree state of the port has changed." ::= 32 els10-27hwDiagTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, els10-27hwDiagCode } DESCRIPTION "Sent whenever the unit's diagnostics have indicated an error." ::= 100 els10-27InvalidConfigurationFileTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, dot1dStpPortDesignatedPort } DESCRIPTION "Diagnostics has detected corrupted configuration data. Default parameter values have been restored." ::= 34 els10-27StInvalidFlashCodeImageTrap TRAP-TYPE ENTERPRISE sigma VARIABLES { els10-27trapSeverity, dot1dStpPortState } DESCRIPTION "An invalid code image was detected in flash memory. An attempt will be made to obtain a valid image." ::= 35 END