CT-HSIMPHYS-MIB DEFINITIONS ::= BEGIN -- ct-hsimphys-mib.txt -- Revision: 01.00.00 -- Part Number: -- Date: July 21, 1998 -- Cabletron Systems, Inc. -- 35 Industrial Way, P.O. Box 5005 -- Rochester, NH 03867-0505 -- (603) 332-9400 -- support@ctron.com -- This module provides an enterprise-specific HSIM container MIB. -- -- This module will be extended, as needed. -- -- Cabletron Systems reserves the right to make changes in -- specification and other information contained in this document -- without prior notice. The reader should consult Cabletron Systems -- to determine whether any such changes have been made. -- -- In no event shall Cabletron Systems be liable for any incidental, -- indirect, special, or consequential damages whatsoever (including -- but not limited to lost profits) arising out of or related to this -- document or the information contained in it, even if Cabletron -- Systems has been advised of, known, or should have known, the -- possibility of such damages. -- -- Cabletron grants vendors, end-users, and other interested parties -- a non-exclusive license to use this Specification in connection -- with the management of Cabletron products. -- Copyright March 98 Cabletron Systems -- This MIB is intended to provide a central repository & link to all -- information about the physical aspect of an HSIM. Physical info -- includes items related to the HW inventory , BOOT, EPLD, and other -- low level information. For the purposes of this MIB, no difference -- is recognized between a permantly-installed "option card", such as -- the onboard WAN interface on the HSIM-W65/75, and an actual WPIM. IMPORTS OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB ctHSIMPhysMib FROM CTRON-MIB-NAMES; --================= HSIM Info =================== hsimInfo OBJECT IDENTIFIER ::= { ctHSIMPhysMib 1 } hsimBoardRev OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the printed circuit board revision level." ::= { hsimInfo 1 } hsimBoardId OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the printed circuit board idenitifer." ::= { hsimInfo 2 } hsimEpldRev OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the programmable logic device revision level." ::= { hsimInfo 3 } hsimEpldId OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the programmable logic device identifier." ::= { hsimInfo 4 } hsimFsbRev OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the first stage boot revision level." ::= { hsimInfo 5 } hsimSsbRev OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the second stage boot revision level." ::= { hsimInfo 6 } hsimFwRev OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the HSIM firmware revision level." ::= { hsimInfo 7 } --=================== HSIM Peripheral MBus Info ===================== hsimPeripheralMBusInfo OBJECT IDENTIFIER ::= { hsimInfo 8 } mBusNumberBoardsInstalled OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is number of MBus boards installed in this unit." ::= { hsimPeripheralMBusInfo 1 } mBusBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF MBusBoardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of MBus boards present in this unit" ::= { hsimPeripheralMBusInfo 2 } mBusBoardEntry OBJECT-TYPE SYNTAX MBusBoardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The value of this object is an MBus board that is present in this unit" INDEX { mBusBoardID } ::= { mBusBoardTable 1 } MBusBoardEntry ::= SEQUENCE { mBusBoardID INTEGER, mBusBoardEntryType INTEGER, mBusBoardOIDPointer OBJECT IDENTIFIER } mBusBoardID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is an index that uniquely identifies the physical MBus board within the system." ::= { mBusBoardEntry 1 } mBusBoardEntryType OBJECT-TYPE SYNTAX INTEGER { unknown(1), cmm(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the type of MBus board installed." ::= { mBusBoardEntry 2 } mBusBoardOIDPointer OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object defines the start of a MIB that can be used to determine more specific information about the given MBus board." ::= { mBusBoardEntry 3 } --=================== HSIM Peripheral WPIM Info ===================== hsimPeripheralWpimInfo OBJECT IDENTIFIER ::= { hsimInfo 9 } wpimNumberBoardsInstalled OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is number of WPIM boards installed in this unit." ::= { hsimPeripheralWpimInfo 1 } wpimBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF WpimBoardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of WPIM boards present in this unit" ::= { hsimPeripheralWpimInfo 2 } wpimBoardEntry OBJECT-TYPE SYNTAX WpimBoardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The value of this object is a WPIM board that is present in this unit" INDEX { wpimBoardID } ::= { wpimBoardTable 1 } WpimBoardEntry ::= SEQUENCE { wpimBoardID INTEGER, wpimBoardEntryType OBJECT IDENTIFIER, wpimBoardOIDPointer OBJECT IDENTIFIER } wpimBoardID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is an index that uniquely identifies this WPIM board." ::= { wpimBoardEntry 1 } wpimBoardEntryType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the type of WPIM board installed. This is within the portWpim branch of the namingTree (1.3.6.1.4.1.52.3.8.1.2.5)" ::= { wpimBoardEntry 2 } wpimBoardOIDPointer OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object defines the start of a MIB that can be used to determine more specific information about the given WPIM board." ::= { wpimBoardEntry 3 } --=================== HSIM Local HW Devices Info ===================== hsimLocalHwDevicesInfo OBJECT IDENTIFIER ::= { hsimInfo 10 } localHwDevicesTable OBJECT-TYPE SYNTAX SEQUENCE OF LocalHwDevicesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of specific hardware devices present in this unit" ::= { hsimLocalHwDevicesInfo 1 } localHwDevicesEntry OBJECT-TYPE SYNTAX LocalHwDevicesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The value of this object is a WPIM module that is present in this unit" INDEX { localHwDeviceID } ::= { localHwDevicesTable 1 } LocalHwDevicesEntry ::= SEQUENCE { localHwDeviceID INTEGER, localHwDeviceType INTEGER, localHwDeviceOperStatus INTEGER, localHwDeviceAdminStatus INTEGER } localHwDeviceID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is an index that uniquely identifies the assoicated local hardware device." ::= { localHwDevicesEntry 1 } localHwDeviceType OBJECT-TYPE SYNTAX INTEGER { unknown(1), siemensMunich32(2), mitelMT8985(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the type of local hardware device. These local hardware devices are those specific ICs unique to this HSIM such as Siemens Munich32, or Mitel MT8985." ::= { localHwDevicesEntry 2 } localHwDeviceOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), -- ready to pass packets down(2), testing(3), -- in some test mode unknown(4), -- status can not be determined -- for some reason. dormant(5) } ACCESS read-only STATUS mandatory DESCRIPTION "This object describes the current state of the device." ::= { localHwDevicesEntry 3 } localHwDeviceAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), -- ready execute down(2), testing(3) -- in some test mode } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used by the Network Management System to request a change in the current state of the device." ::= { localHwDevicesEntry 4 } END