CTRON-IPX-ROUTER-MIB DEFINITIONS ::= BEGIN -- ctron-ipx-router-mib.txt -- Revision: 1.01.03 -- Part Number: 2170987 -- Date: August 11, 1995 -- Cabletron Systems, Inc. -- 35 Industrial Way, P.O. Box 5005 -- Rochester, NH 03867-0505 -- (603) 332-9400 -- support@ctron.com -- This module provides authoritative definitions for Cabletron's -- enterprise specific IPX Routing Services MIB. -- -- -- This module will be extended as required. -- -- Cabletron Systems reserves the right to make changes in -- specification and other information contained in this document -- without prior notice. The reader should consult Cabletron Systems -- to determine whether any such changes have been made. -- -- In no event shall Cabletron Systems be liable for any incidental, -- indirect, special, or consequential damages whatsoever (including -- but not limited to lost profits) arising out of or related to this -- document or the information contained in it, even if Cabletron -- Systems has been advised of, known, or should have known, the -- possibility of such damages. -- -- Cabletron grants vendors, end-users, and other interested parties -- a non-exclusive license to use this Specification in connection -- with the management of Cabletron products. -- Copyright August 95 Cabletron Systems IMPORTS OBJECT-TYPE FROM RFC-1212 DisplayString, PhysAddress FROM RFC1213-MIB MacAddress FROM BRIDGE-MIB nwRtrProtoSuites FROM ROUTER-OIDS Counter, TimeTicks, Gauge FROM RFC1155-SMI; -- The IPX Router Group. nwIpxRouter OBJECT IDENTIFIER ::= { nwRtrProtoSuites 2 } nwIpxMibs OBJECT IDENTIFIER ::= { nwIpxRouter 1 } nwIpxComponents OBJECT IDENTIFIER ::= { nwIpxRouter 2 } -- IPX Router Component Groups nwIpxSystem OBJECT IDENTIFIER ::= { nwIpxComponents 1 } nwIpxForwarding OBJECT IDENTIFIER ::= { nwIpxComponents 2 } nwIpxTopology OBJECT IDENTIFIER ::= { nwIpxComponents 4 } nwIpxFib OBJECT IDENTIFIER ::= { nwIpxComponents 5 } nwIpxEndSystems OBJECT IDENTIFIER ::= { nwIpxComponents 6 } nwIpxAccessControl OBJECT IDENTIFIER ::= { nwIpxComponents 7 } nwIpxFilters OBJECT IDENTIFIER ::= { nwIpxComponents 8 } nwIpxRedirector OBJECT IDENTIFIER ::= { nwIpxComponents 9 } nwIpxEvent OBJECT IDENTIFIER ::= { nwIpxComponents 10 } nwIpxWorkGroup OBJECT IDENTIFIER ::= { nwIpxComponents 11 } -- IPX Router System Groups nwIpxSysConfig OBJECT IDENTIFIER ::= { nwIpxSystem 1 } nwIpxSysAdministration OBJECT IDENTIFIER ::= { nwIpxSystem 2 } -- IPX Router Forwarding Groups nwIpxFwdSystem OBJECT IDENTIFIER ::= { nwIpxForwarding 1 } nwIpxFwdInterfaces OBJECT IDENTIFIER ::= { nwIpxForwarding 2 } nwIpxFwdCounters OBJECT IDENTIFIER ::= { nwIpxFwdSystem 1 } nwIpxFwdIfConfig OBJECT IDENTIFIER ::= { nwIpxFwdInterfaces 1 } nwIpxFwdIfCounters OBJECT IDENTIFIER ::= { nwIpxFwdInterfaces 2 } -- IPX Router Routing Groups nwIpxDistanceVector OBJECT IDENTIFIER ::= { nwIpxTopology 1 } nwIpxLinkState OBJECT IDENTIFIER ::= { nwIpxTopology 2 } nwIpxRip OBJECT IDENTIFIER ::= { nwIpxDistanceVector 1 } nwIpxSap OBJECT IDENTIFIER ::= { nwIpxDistanceVector 2 } nwIpxRipSystem OBJECT IDENTIFIER ::= { nwIpxRip 1 } nwIpxRipInterfaces OBJECT IDENTIFIER ::= { nwIpxRip 2 } nwIpxRipDatabase OBJECT IDENTIFIER ::= { nwIpxRip 3 } nwIpxRipFilters OBJECT IDENTIFIER ::= { nwIpxRip 4 } nwIpxRipConfig OBJECT IDENTIFIER ::= { nwIpxRipSystem 1 } nwIpxRipCounters OBJECT IDENTIFIER ::= { nwIpxRipSystem 2 } nwIpxRipIfConfig OBJECT IDENTIFIER ::= { nwIpxRipInterfaces 1 } nwIpxRipIfCounters OBJECT IDENTIFIER ::= { nwIpxRipInterfaces 2 } nwIpxSapSystem OBJECT IDENTIFIER ::= { nwIpxSap 1 } nwIpxSapInterfaces OBJECT IDENTIFIER ::= { nwIpxSap 2 } nwIpxSapServerTable OBJECT IDENTIFIER ::= { nwIpxSap 3 } nwIpxSapFilters OBJECT IDENTIFIER ::= { nwIpxSap 4 } nwIpxSapConfig OBJECT IDENTIFIER ::= { nwIpxSapSystem 1 } nwIpxSapCounters OBJECT IDENTIFIER ::= { nwIpxSapSystem 2 } nwIpxSapIfConfig OBJECT IDENTIFIER ::= { nwIpxSapInterfaces 1 } nwIpxSapIfCounters OBJECT IDENTIFIER ::= { nwIpxSapInterfaces 2 } nwIpxNlsp OBJECT IDENTIFIER ::= { nwIpxLinkState 1 } -- IPX Router Host End Systems Groups nwIpxHostsSystem OBJECT IDENTIFIER ::= { nwIpxEndSystems 1 } nwIpxHostsInterfaces OBJECT IDENTIFIER ::= { nwIpxEndSystems 2 } nwIpxHostsToMedia OBJECT IDENTIFIER ::= { nwIpxEndSystems 3 } -- IPX Router Access Control Group -- IPX Router Redirector Group nwIpxNetBIOS OBJECT IDENTIFIER ::= { nwIpxRedirector 1 } nwIpxBroadcast OBJECT IDENTIFIER ::= { nwIpxRedirector 2 } nwIpxEcho OBJECT IDENTIFIER ::= { nwIpxRedirector 3 } nwIpxNetBIOSSystem OBJECT IDENTIFIER ::= { nwIpxNetBIOS 1 } nwIpxNetBIOSInterface OBJECT IDENTIFIER ::= { nwIpxNetBIOS 2 } nwIpxNetBIOSConfig OBJECT IDENTIFIER ::= { nwIpxNetBIOSSystem 1 } nwIpxNetBIOSCounters OBJECT IDENTIFIER ::= { nwIpxNetBIOSSystem 2 } nwIpxNetBIOSIfConfig OBJECT IDENTIFIER ::= { nwIpxNetBIOSInterface 1} nwIpxNetBIOSIfCounters OBJECT IDENTIFIER ::= { nwIpxNetBIOSInterface 2} nwIpxBroadcastSystem OBJECT IDENTIFIER ::= { nwIpxBroadcast 1 } nwIpxBroadcastInterface OBJECT IDENTIFIER ::= { nwIpxBroadcast 2 } nwIpxBroadcastConfig OBJECT IDENTIFIER ::= { nwIpxBroadcastSystem 1 } nwIpxBroadcastCounters OBJECT IDENTIFIER ::= { nwIpxBroadcastSystem 2 } nwIpxBroadcastIfConfig OBJECT IDENTIFIER ::= { nwIpxBroadcastInterface 1 } nwIpxBroadcastIfCounters OBJECT IDENTIFIER ::= { nwIpxBroadcastInterface 2 } nwIpxEchoSystem OBJECT IDENTIFIER ::= { nwIpxEcho 1 } nwIpxEchoInterface OBJECT IDENTIFIER ::= { nwIpxEcho 2 } nwIpxEchoConfig OBJECT IDENTIFIER ::= { nwIpxEchoSystem 1 } nwIpxEchoCounters OBJECT IDENTIFIER ::= { nwIpxEchoSystem 2 } nwIpxEchoIfConfig OBJECT IDENTIFIER ::= { nwIpxEchoInterface 1 } nwIpxEchoIfCounters OBJECT IDENTIFIER ::= { nwIpxEchoInterface 2 } -- IPX Router Event Log Group nwIpxEventLogConfig OBJECT IDENTIFIER ::= { nwIpxEvent 1 } nwIpxEventLogFilterTable OBJECT IDENTIFIER ::= { nwIpxEvent 2 } nwIpxEventLogTable OBJECT IDENTIFIER ::= { nwIpxEvent 3 } -- IPX Router Work-Group Group IpxAddress ::= OCTET STRING -- MacAddress ::= OCTET STRING (SIZE (6)) -- IPX MIB Group -- This group contains information about the revision level of this -- MIB within the device. It allows verification of the released -- version without having to read other objects. nwIpxMibRevText OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current revision level of the IPX MIB in textual format." ::= { nwIpxMibs 1 } -- IPX Router System Group -- This group contains the objects related to the IPX Router at a -- global device-wide level. -- IPX System Configuration Group -- This group contains the objects that pertain to the setup and -- configuration of the IPX routing services at a global, -- device-wide level. nwIpxSysRouterId OBJECT-TYPE SYNTAX IpxAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IPX Address used to uniquely identify the host (device) running IPX Routing Services. The value of nwIpxSysRouterId is equal to the highest IPX address assigned in the IPX Address Table." ::= { nwIpxSysConfig 1 } -- IPX System Administration Group -- This group contains the objects that pertain to the administration of -- IPX routing services at a global, device-wide level. nwIpxSysAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- shutdown the router enabled(3) -- startup the router } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of IPX Routing Services system-wide. Enabled (3) causes IPX Routing Services to become active on all router ports configured and enabled for IPX Routing Services. Disabled (2) causes IPX routing services to become inactive system-wide." DEFVAL { disabled } ::= { nwIpxSysAdministration 1 } nwIpxSysOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- not running enabled(3), -- running pending-disable(4), -- shut-down in progress pending-enable(5), -- start-up in progress invalid-config(6) -- not running,invalid config } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the operating condition of IPX Routing Services system-wide. The value of nwIpxSysOperStatus indicates any problem with your IPX Routing Services configuration. A value of 6 indicates that regardless of the value of nwIpxSysAdminStatus, IPX Routing Services is not operating because of an invalid configuration." ::= { nwIpxSysAdministration 2 } nwIpxSysAdminReset OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following reset(2) -- force a reset } ACCESS read-write STATUS mandatory DESCRIPTION "Resets IPX Routing Services system-wide. Reset (2) forces a restart of IPX Routing Services without a graceful shutdown on any active router ports and without affecting any other routing services." DEFVAL { other } ::= { nwIpxSysAdministration 3 } nwIpxSysOperationalTimel OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that nwIpxSysOperStatus has been in its current administrative state." ::= { nwIpxSysAdministration 4 } nwIpxSysVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current revision level of the IPX Routing Services firmware in textual format." ::= { nwIpxSysAdministration 5 } -- IPX Forwarding Group -- This group contains the managed objects used to setup and configure -- the IPX router port for packet forwarding as well as the aggregate -- and per-interface IPX packet forwarding counters. -- IPX System-wide Packet Forwarding Counters -- This group contains the aggregate (device-wide) IPX packet forwarding -- counters. The byte counters include bytes for the network layer on -- up, framing is not included. nwIpxFwdCtrAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the aggregate (system-wide) IPX packet and byte counters. Enabled (3) causes these counters to become active. Disabled (2) causes these counters to become inactive." DEFVAL { enabled } ::= { nwIpxFwdCounters 1 } nwIpxFwdCtrReset OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the aggregate (system-wide) IPX packet and byte counters. Reset (2) resets the IPX aggregate counters to 0. nwIpxFwdCtrOperationalTime is also reset to 0." DEFVAL { other } ::= { nwIpxFwdCounters 2 } nwIpxFwdCtrOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that nwIpxFwdCtrAdminStatus has been in the current state." ::= { nwIpxFwdCounters 3 } nwIpxFwdCtrInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been received, system-wide, during nwIpxFwdCtrOperationalTime." ::= { nwIpxFwdCounters 4 } nwIpxFwdCtrOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been transmitted, system-wide, during nwIpxFwdCtrOperationalTime." ::= { nwIpxFwdCounters 5 } nwIpxFwdCtrFwdPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been forwarded, system-wide, during nwIpxFwdCtrOperationalTime." ::= { nwIpxFwdCounters 6 } nwIpxFwdCtrFilteredPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been administratively filtered, system-wide, during nwIpxFwdCtrOperationalTime." ::= { nwIpxFwdCounters 7 } nwIpxFwdCtrDiscardPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been discarded, system-wide, during nwIpxFwdCtrOperationalTime." ::= { nwIpxFwdCounters 8 } nwIpxFwdCtrAddrErrPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been discarded, system-wide, during nwIpxFwdCtrOperationalTime, because of addressing errors in the IPX header." ::= { nwIpxFwdCounters 9 } nwIpxFwdCtrLenErrPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been discarded, system-wide, during nwIpxFwdCtrOperationalTime, because an invalid packet length is contained in the IPX header." ::= { nwIpxFwdCounters 10 } nwIpxFwdCtrHdrErrPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been discarded, system-wide, during nwIpxFwdCtrOperationalTime, because of an invalid IPX header." ::= { nwIpxFwdCounters 11 } nwIpxFwdCtrInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX packets that have been received, system-wide, during nwIpxFwdCtrOperationalTime." ::= { nwIpxFwdCounters 12 } nwIpxFwdCtrOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX packets that have been transmitted, system-wide, during nwIpxFwdCtrOperationalTime." ::= { nwIpxFwdCounters 13 } nwIpxFwdCtrFwdBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX packets that have been forwarded, system-wide, during nwIpxFwdCtrOperationalTime." ::= { nwIpxFwdCounters 14 } nwIpxFwdCtrFilteredBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX packets that have been administratively filtered, system-wide, during nwIpxFwd-CtrOperationalTime." ::= { nwIpxFwdCounters 15 } nwIpxFwdCtrDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX packets that have been discarded, system-wide during nwIpxFwdCtrOperationalTime." ::= { nwIpxFwdCounters 16 } nwIpxFwdCtrHostInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been successfully delivered to the local host, during nwIpxFwdCtrOperationalTime." ::= { nwIpxFwdCounters 17 } nwIpxFwdCtrHostOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been transmitted by the local host, during nwIpxFwdCtrOperationalTime." ::= { nwIpxFwdCounters 18 } nwIpxFwdCtrHostDiscardPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been discarded by the local host, during nwIpxFwdCtrOperationalTime, due to a lack of host resources." ::= { nwIpxFwdCounters 19 } nwIpxFwdCtrHostInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX packets that have been received by the local host, during nwIpxFwdCtrOperationalTime." ::= { nwIpxFwdCounters 20 } nwIpxFwdCtrHostOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX packets that have been transmitted by the local host, during nwIpxFwdCtrOperationalTime." ::= { nwIpxFwdCounters 21 } nwIpxFwdCtrHostDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX packets that have been discarded by the local host, during nwIpxFwdCtrOperationalTime due to a lack of host resources." ::= { nwIpxFwdCounters 22 } -- IPX Forwarding Interface Table -- This table contains the managed objects used to set-up and configure -- each router port. nwIpxFwdIfTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxFwdIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry for each router port. This table is indexed by nwIpxFwdIfIndex, which indicates the value of MIB2 ifIndex, which identifies the router port for which the entry exists." ::= { nwIpxFwdIfConfig 1 } nwIpxFwdIfEntry OBJECT-TYPE SYNTAX NwIpxFwdIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry specifies the IPX Routing Services configuration for the router port for which the entry exists." INDEX { nwIpxFwdIfIndex } ::= { nwIpxFwdIfTable 1 } NwIpxFwdIfEntry ::= SEQUENCE { nwIpxFwdIfIndex INTEGER, nwIpxFwdIfAdminStatus INTEGER, nwIpxFwdIfOperStatus INTEGER, nwIpxFwdIfOperationalTime TimeTicks, nwIpxFwdIfControl INTEGER, nwIpxFwdIfMtu INTEGER, nwIpxFwdIfForwarding INTEGER, nwIpxFwdIfFrameType INTEGER, nwIpxFwdIfAclIdentifier INTEGER, nwIpxFwdIfAclStatus INTEGER, nwIpxFwdIfCacheControl INTEGER, nwIpxFwdIfCacheEntries Counter, nwIpxFwdIfCacheHits Counter, nwIpxFwdIfCacheMisses Counter } nwIpxFwdIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the value of MIB 2 ifindex, which identifies the router port for which the entry exists." ::= { nwIpxFwdIfEntry 1 } nwIpxFwdIfAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of IPX Routing Services on the router port for which the entry exists. Enabled (3) causes IPX Routing Services to become active. Disabled (2) causes it to become inactive." DEFVAL { enabled } ::= { nwIpxFwdIfEntry 2 } nwIpxFwdIfOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- not running enabled(3), -- running pending-disable(4), -- shut-down in progress pending-enable(5), -- start-up in progress invalid-config(6) -- not running,invalid config } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current operating condition of IPX Routing Services on the router port for which the entry exists. The value of nwIpxFwdIfOperStatus indicates any problem with the configuration of IPX Routing Services on the router port. A value of 6 indicates that regardless of the state of nwIpxFwdIfAdminStatus IPX Routing Services is not operating because of an invalid port-level configuration." ::= { nwIpxFwdIfEntry 3 } nwIpxFwdIfOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that nwIpxFwdIfOperStatus has been in its current state." ::= { nwIpxFwdIfEntry 4 } nwIpxFwdIfControl OBJECT-TYPE SYNTAX INTEGER { other(1), add(2), delete(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs. Setting this object has no effect." DEFVAL { delete } ::= { nwIpxFwdIfEntry 5 } nwIpxFwdIfMtu OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the Maximum Transmission Unit (MTU) for IPX packets on the router port for which the entry exists. This includes the IPX header and data but does not include framing." DEFVAL { 1500 } ::= { nwIpxFwdIfEntry 6 } nwIpxFwdIfForwarding OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls forwarding of IPX packets on the router port for which the entry exists. Enabled (3) causes IPX packets to be forwarded. Disabled (2) prevents IPX packets from being forwarded." DEFVAL { disabled } ::= { nwIpxFwdIfEntry 7 } nwIpxFwdIfFrameType OBJECT-TYPE SYNTAX INTEGER { -- valid media types other(1), -- experimental ethernet(2), -- ethernet snap(3), -- enet,fddi,and token ring i8022(4), -- enet, token ring, and fddi novell(6), -- ethernet and fddi nativewan(8), -- wan media types encapenet(9), -- wan media types encapenet8022(10), -- wan media types encapenetsnap(11), -- wan media types encapenetnovell(12), -- wan media types encaptr8022(13), -- wan media types encaptrsnap(14), -- wan media types encapfddi8022(15), -- wan media types encapfddisnap(16), -- wan media types canonical(17) -- special, tbd } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the framing type for IPX packets forwarded on the router port for which the entry exists. Some frame types are valid for specific media types. The comments reflect those valid media types." DEFVAL { i8022 } ::= { nwIpxFwdIfEntry 8 } nwIpxFwdIfAclIdentifier OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the Access Control ID of the Access Control List in effect for IPX packets being routed on the router port for which the entry exists. A value of 0 indicates that no Access Control List is in effect." DEFVAL { 0 } ::= { nwIpxFwdIfEntry 9 } nwIpxFwdIfAclStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls the operation of any Access Control List configured for IPX traffic on the router port for which the entry exists. Enabled (3) applies the Access Control List indicated by the value of nwIpxFwdIfAclIdentifier to all IPX traffic being routed to the port. Disabled (2) prevents the Access Control List from being applied." DEFVAL { disabled } ::= { nwIpxFwdIfEntry 10 } nwIpxFwdIfCacheControl OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls IPX Address caching on the router port for which the entry exists. When IPX Address caching is enabled, IPX Addresses used for address validation, filtering, and forwarding are stored in the cache. This cache is checked first before doing a full route table lookup, which speeds up the switching process. Enabled (3) turns on IPX Address caching. Disabled (2) turns it off." DEFVAL { enable } ::= { nwIpxFwdIfEntry 11 } nwIpxFwdIfCacheEntries OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of entries in the IPX Address cache on the router port for which the entry exists." ::= { nwIpxFwdIfEntry 12 } nwIpxFwdIfCacheHits OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of times entries in the IPX Adddress cache have been used to provide the IPX Address required to validate, filter, or forward an IPX packet on the router port." ::= { nwIpxFwdIfEntry 13 } nwIpxFwdIfCacheMisses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of times the IPX Address required to validate, filter, or forward an IPX packet on the router port was not found in the IPX Address cache." ::= { nwIpxFwdIfEntry 14 } -- The IPX Interface Address Table -- This table contains the managed object used to setup and configure -- IPX addresses on a per router port basis. nwIpxAddressTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxAddrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry for each Novell network address assigned to each router port." ::= { nwIpxFwdIfConfig 2 } nwIpxAddrEntry OBJECT-TYPE SYNTAX NwIpxAddrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry specifies the Novell network addressing information for the logical Novll network for which the entry exists." INDEX { nwIpxAddrIfIndex, nwIpxAddrIfAddress } ::= { nwIpxAddressTable 1 } NwIpxAddrEntry ::= SEQUENCE { nwIpxAddrIfIndex INTEGER, nwIpxAddrIfAddress IpxAddress, nwIpxAddrIfControl INTEGER, nwIpxAddrIfAddrType INTEGER } nwIpxAddrIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the value of MIB 2 ifindex, which identifies the router port for which the entry exists." ::= { nwIpxAddrEntry 1 } nwIpxAddrIfAddress OBJECT-TYPE SYNTAX IpxAddress ACCESS read-only STATUS mandatory DESCRIPTION "This is the Novell network number assigned to the logical Novell network for which the entry exists. The IpxAddress consists of a network number of 4 octets." ::= { nwIpxAddrEntry 2 } nwIpxAddrIfControl OBJECT-TYPE SYNTAX INTEGER { other(1), add(2), delete(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Set this object to add or delete this entry from the table." DEFVAL { add } ::= { nwIpxAddrEntry 3 } nwIpxAddrIfAddrType OBJECT-TYPE SYNTAX INTEGER { other(1), primary(2), secondary(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether the Novell network number, nwIpxAddrIfAddress, is the primary or secondary address for the router port." DEFVAL { primary } ::= { nwIpxAddrEntry 4 } -- IPX Forwarding Interfaces Counter Table -- This table contains the objects that specify the packet and byte counters -- for each configured IPX router port. nwIpxFwdIfCtrTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxFwdIfCtrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry for each router port configured and enabled for IPX Routing Services." ::= { nwIpxFwdIfCounters 1 } nwIpxFwdIfCtrEntry OBJECT-TYPE SYNTAX NwIpxFwdIfCtrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry indicates the current packet and byte count of IPX packets on the port for which the entry exists." INDEX { nwIpxFwdIfCtrIfIndex } ::= { nwIpxFwdIfCtrTable 1 } NwIpxFwdIfCtrEntry ::= SEQUENCE { nwIpxFwdIfCtrIfIndex INTEGER, nwIpxFwdIfCtrAdminStatus INTEGER, nwIpxFwdIfCtrReset INTEGER, nwIpxFwdIfCtrOperationalTime TimeTicks, nwIpxFwdIfCtrInPkts Counter, nwIpxFwdIfCtrOutPkts Counter, nwIpxFwdIfCtrFwdPkts Counter, nwIpxFwdIfCtrFilteredPkts Counter, nwIpxFwdIfCtrDiscardPkts Counter, nwIpxFwdIfCtrAddrErrPkts Counter, nwIpxFwdIfCtrLenErrPkts Counter, nwIpxFwdIfCtrHdrErrPkts Counter, nwIpxFwdIfCtrInBytes Counter, nwIpxFwdIfCtrOutBytes Counter, nwIpxFwdIfCtrFwdBytes Counter, nwIpxFwdIfCtrFilteredBytes Counter, nwIpxFwdIfCtrDiscardBytes Counter, nwIpxFwdIfCtrHostInPkts Counter, nwIpxFwdIfCtrHostOutPkts Counter, nwIpxFwdIfCtrHostDiscardPkts Counter, nwIpxFwdIfCtrHostInBytes Counter, nwIpxFwdIfCtrHostOutBytes Counter, nwIpxFwdIfCtrHostDiscardBytes Counter } nwIpxFwdIfCtrIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the value of MIB 2 ifindex, which identifies the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 1 } nwIpxFwdIfCtrAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the per-port IPX packet and byte counters on the router port for which the entry exists. Enabled (3) causes these counters to become active. Disabled (2) causes these counters to become inactive." DEFVAL { enabled } ::= { nwIpxFwdIfCtrEntry 2 } nwIpxFwdIfCtrReset OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the per-port IPX packet and byte counters on the router port for which this entry exists. Reset (2) resets the counters to 0. nwIpxFwdIfCtrOperationalTime is also reset to 0." DEFVAL { other } ::= { nwIpxFwdIfCtrEntry 3 } nwIpxFwdIfCtrOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that nwIpxFwdIfCtrAdminStatus has been in the current state." ::= { nwIpxFwdIfCtrEntry 4 } nwIpxFwdIfCtrInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been received, during nwIpxFwdIfCtrOperationaltime, on the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 5 } nwIpxFwdIfCtrOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been transmitted, during nwIpxFwdIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 6 } nwIpxFwdIfCtrFwdPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been forwarded, during nwIpxFwdIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 7 } nwIpxFwdIfCtrFilteredPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been administratively filtered, during nwIpxFwdIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 8 } nwIpxFwdIfCtrDiscardPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been discarded (dropped), during nwIpxFwdIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 9 } nwIpxFwdIfCtrAddrErrPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been discarded because of IPX addressing errors in the IPX header, during nwIpxFwdIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 10 } nwIpxFwdIfCtrLenErrPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been discarded because an invalid packet length was contained in the IPX header, during nwIpxFwdIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 11 } nwIpxFwdIfCtrHdrErrPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been discarded because of an invalid IPX header, during nwIpxFwdIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 12 } nwIpxFwdIfCtrInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX packets that have been received, during nwIpxFwdIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 13 } nwIpxFwdIfCtrOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX packets that have been transmitted, during nwIpxFwdIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 14 } nwIpxFwdIfCtrFwdBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX packets that have been forwarded, during nwIpxFwdCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 15 } nwIpxFwdIfCtrFilteredBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX packets administratively filtered, during nwIpxFwdIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 16 } nwIpxFwdIfCtrDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX packets that have been discarded, during nwIpxFwdIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 17 } nwIpxFwdIfCtrHostInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been successfully delivered to the local host, during nwIpxFwdIfCtrOperationalTime, that were received on the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 18 } nwIpxFwdIfCtrHostOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been forwarded by the local host, during nwIpxFwdIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 19 } nwIpxFwdIfCtrHostDiscardPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX packets that have been discarded by the local host, due to a lack of host resources, during nwIpxFwdIfCtrOperationalTime, that were received on the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 20 } nwIpxFwdIfCtrHostInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX packets that have been successfully delivered to the local host, during nwIpxFwdIfCtrOperationalTime, that were received on the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 21 } nwIpxFwdIfCtrHostOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX packets that have been transmitted by the local host, during nwIpxFwdIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 22 } nwIpxFwdIfCtrHostDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX packets that have been discarded by the local host, due to a lack of host resources that were received, during nwIpxFwdIfCtrOperationalTime, that were received on the router port for which the entry exists." ::= { nwIpxFwdIfCtrEntry 23 } -- DistanceVector-based Protocols -- This group contains the managed objects for RIP, IPX DistanceVector based -- routing. -- IPX RIP System Configuration Parameters -- This group contains the objects that pertain to the setup and -- configuration of the IPX RIP DistanceVector based routing protocol. nwIpxRipAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- shutdown the router enabled(3) -- startup the router } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the IPX-RIP routing protocol system-wide. Enabled (3) causes IPX-RIP to become active on all router ports configured and enabled for IPX Routing Services. Disabled (2) causes IPX-RIP to become inactive." DEFVAL { disabled } ::= { nwIpxRipConfig 1 } nwIpxRipOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- not running enabled(3), -- running pending-disable(4), -- shut-down in progress pending-enable(5) -- start-up in progress } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current operating condition of IPX-RIP system-wide. The value of nwIpxRipOperStatus indicates any problem with your IPX-RIP configuration. A value of 6 indicates that regardless of the value of nwIpxRipAdminStatus, IPX-RIP is not operating because of an invalid configuration." ::= { nwIpxRipConfig 2 } nwIpxRipAdminReset OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following reset(2) -- force a reset } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the IPX-RIP routing protocol. Reset (2) forces a system-wide restart of IPX-RIP, without a graceful shutdown on any active router ports." DEFVAL { other } ::= { nwIpxRipConfig 3 } nwIpxRipOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that nwIpxRipOperStatus has been in its current state." ::= { nwIpxRipConfig 4 } nwIpxRipVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current revision level of the IPX-RIP routing protocol firmware, in textual format." ::= { nwIpxRipConfig 5 } nwIpxRipStackSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the stack size of the IPX-RIP routing protocol thread. In order for a change of this value to take effect, the protocol (nwIpxRipAdminReset), IPX Routing Services (nwIpxSysAdminReset), or the device running Routing Services must be reset." DEFVAL { 4096 } ::= { nwIpxRipConfig 6 } nwIpxRipThreadPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the run-time execution priority of the IPX-RIP routing protocol thread. In order for a change of this value to take effect, IPX-RIP (nwIpxRipAdminReset), IPX Routing Services (nwIpxAdminReset), or the device running Routing services must be reset." DEFVAL { 127 } ::= { nwIpxRipConfig 7 } nwIpxRipDatabaseThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the run-time maximum number of IPX-RIP entries that can be held in the IPX-RIP route table." DEFVAL { 2000 } ::= { nwIpxRipConfig 8 } nwIpxRipAgeOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the amount of time, in seconds, that an inactive route table entry remains in the IPX-RIP route table before it is aged-out." DEFVAL { 180 } ::= { nwIpxRipConfig 9 } nwIpxRipHoldDown OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the amount of time, in seconds, to wait before removing an entry from the route table, after receiving an update indicating that the destination has become unreachable. All routers exchanging IPX-RIP information must have the same hold down time. The time must be long enough to allow all participating routers to receive the same update." DEFVAL { 120 } ::= { nwIpxRipConfig 10 } -- IPX RIP System (aggregate) Counters -- This group contains the aggregate (device-wide) IPX RIP packet and -- byte counters. nwIpxRipCtrAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the aggregate system-wide IPX-RIP packet and byte counters. Enabled (3) causes these counters to become active on all router ports. Disabled (2) causes these counters to become inactive." DEFVAL { enabled } ::= { nwIpxRipCounters 1 } nwIpxRipCtrReset OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the aggregate system-wide IPX-RIP protocol packet and byte counters. Reset (2) resets the IPX-RIP aggregate counters to 0. nwIpxRipCtrOperationalTime is also reset to 0." DEFVAL { other } ::= { nwIpxRipCounters 2 } nwIpxRipCtrOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that nwIpxRipCtrAdminStatus has been in the current state." ::= { nwIpxRipCounters 3 } nwIpxRipCtrInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX-RIP packets that have been received, system-wide, during nwIpxRipCtrOperationalTime." ::= { nwIpxRipCounters 4 } nwIpxRipCtrOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX-RIP packets that have been transmitted, system-wide, during nwIpxRipCtrOperationalTime." ::= { nwIpxRipCounters 5 } nwIpxRipCtrFilteredPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX-RIP packets that have been administratively filtered, system-wide, during` nwIpxRipCtrOperationalTime." ::= { nwIpxRipCounters 6 } nwIpxRipCtrDiscardPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX-RIP packets that have been discarded, system-wide, during nwIpxRipCtrOperationalTime." ::= { nwIpxRipCounters 7 } nwIpxRipCtrInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX-RIP packets that have been received, system-wide, during nwIpxRipCtrOperationalTime." ::= { nwIpxRipCounters 8 } nwIpxRipCtrOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX-RIP packets that have been transmitted, system-wide, during nwIpxRipCtrOperationalTime." ::= { nwIpxRipCounters 9 } nwIpxRipCtrFilteredBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX-RIP packets that have been administratively filtered, system-wide, during nwIpxRipCtrOperationalTime." ::= { nwIpxRipCounters 10 } nwIpxRipCtrDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX-RIP packets that have been discarded, during nwIpxRipCtrOperationalTime." ::= { nwIpxRipCounters 11 } -- IPX RIP Interface Table -- This table contains the managed objects used to setup and configure -- RIP on a per router port basis. nwIpxRipIfTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxRipIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry for each router port. Each entry can contain different values, allowing the routing protocol configuration to vary from router port to router port. This table is indexed by nwIpxRipIfIndex, which indicates the value of MIB 2 ifindex, which identifies the router port for which each entry exists." ::= { nwIpxRipIfConfig 1 } nwIpxRipIfEntry OBJECT-TYPE SYNTAX NwIpxRipIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the IPX-RIP configuration for the router port for which the entry exists." INDEX { nwIpxRipIfIndex } ::= { nwIpxRipIfTable 1 } NwIpxRipIfEntry ::= SEQUENCE { nwIpxRipIfIndex INTEGER, nwIpxRipIfAdminStatus INTEGER, nwIpxRipIfOperStatus INTEGER, nwIpxRipIfOperationalTime TimeTicks, nwIpxRipIfVersion INTEGER, nwIpxRipIfAdvertisement INTEGER, nwIpxRipIfFloodDelay INTEGER, nwIpxRipIfRequestDelay INTEGER, nwIpxRipIfPriority INTEGER, nwIpxRipIfHelloTimer INTEGER, nwIpxRipIfSplitHorizon INTEGER, nwIpxRipIfPoisonReverse INTEGER, nwIpxRipIfSnooping INTEGER, nwIpxRipIfType INTEGER, nwIpxRipIfXmitCost INTEGER, nwIpxRipIfAclIdentifier INTEGER, nwIpxRipIfAclStatus INTEGER } nwIpxRipIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the value of MIB 2 ifindex, which identifies the router port for which the entry exists." ::= { nwIpxRipIfEntry 1 } nwIpxRipIfAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the IPX-RIP routing protocol on the router port for which the entry exists. Enabled (3) causes IPX-RIP to become active on the router port. Disabled (2) causes RIP to become inactive." DEFVAL { disabled } ::= { nwIpxRipIfEntry 2 } nwIpxRipIfOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- not running enabled(3), -- running pending-disable(4), -- shut-down in progress pending-enable(5) -- start-up in progress } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current operating condition of the IPX-RIP routing protocol on the router port for which the entry exists. The value of nwIpxRipIfOperStatus indicates any problem with your IPX-RIP configuration on the router port. A value of 6 indicates that regardless of the value of nwIpxRipIfAdminStatus, IPX-RIP is not operating on the router port because of an invalid configuration." ::= { nwIpxRipIfEntry 3 } nwIpxRipIfOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that nwIpxRipIfOperStatus has been in its current state." ::= { nwIpxRipIfEntry 4 } nwIpxRipIfVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the revision level of the IPX-RIP routing protocol in textual format." DEFVAL { 1 } ::= { nwIpxRipIfEntry 5 } nwIpxRipIfAdvertisement OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Sets the interval, in seconds, at which IPX-RIP advertises its route table on the router port for which the entry exists. Change this value to cause IPX-RIP to advertise its route table more or less frequently." DEFVAL { 60 } ::= { nwIpxRipIfEntry 6 } nwIpxRipIfFloodDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the length of time, in seconds, that the IPX-RIP routing protocol will wait after discovering that a directly connected route has gone down, before flooding updates (triggered updates) on the router port for which the entry exists. A value of 0 specifies that if a directly connected route goes down, updates will be sent immediately." DEFVAL { 2 } ::= { nwIpxRipIfEntry 7 } nwIpxRipIfRequestDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the length of time, in seconds, that the IPX-RIP routing protocol will wait after receiving a route request packet before sending a response on the router port for which the entry exists. A value of 0 specifies that if a route request packet is received on the port, a response will be sent immediately." DEFVAL { 6 } ::= { nwIpxRipIfEntry 8 } nwIpxRipIfPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs. Setting this object has no effect." DEFVAL { 1 } ::= { nwIpxRipIfEntry 9 } nwIpxRipIfHelloTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs. Setting this object has no effect." DEFVAL { 10 } ::= { nwIpxRipIfEntry 10 } nwIpxRipIfSplitHorizon OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls the operation of Split Horizon on the router port for which the entry exists. When Split Horizon is enabled, IPX-RIP keeps track of which router port route information is received on, and prevents information about a route from being sent back out the same router port it was received on." DEFVAL { enabled } ::= { nwIpxRipIfEntry 11 } nwIpxRipIfPoisonReverse OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls the operation of Poison Reverse on the router port for which the entry exists. When Poison Reverse is enabled, IPX-RIP advertises any downed route as unreachable during the period of time that it must wait (nwIpxRipHoldDown) before removing the route from the route table." DEFVAL { disabled } ::= { nwIpxRipIfEntry 12 } nwIpxRipIfSnooping OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls the operation of IPX-RIP Snooping on the router port. When RIP Snooping is enabled the IPX-RIP routing protocol operates in passive mode, so that it receives route information, builds and maintains a route table, but does not advertise or send updates on the router port for which the entry exists." DEFVAL { disabled } ::= { nwIpxRipIfEntry 13 } nwIpxRipIfType OBJECT-TYPE SYNTAX INTEGER { other(1), bma(2), nbma(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the directly connected network segment does or does not support broadcast media access. If broadcast media access is supported, IPX-RIP advertisements are sent out one broadcast packet per router port. If broadcast media access is not supported, IPX-RIP advertisements are sent to each neighbor directly." DEFVAL { bma } ::= { nwIpxRipIfEntry 14 } nwIpxRipIfXmitCost OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the common MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs. Setting this object has no effect." DEFVAL { 0 } ::= { nwIpxRipIfEntry 15 } nwIpxRipIfAclIdentifier OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the Access Control ID of the access control list in effect for IPX-RIP routing protocol packets on the router port for which the entry exists. A value of 0 indicates that there is no access control list in effect for IPX-RIP routing protocol packets on the router port." DEFVAL { 0 } ::= { nwIpxRipIfEntry 16 } nwIpxRipIfAclStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls the operation of the access control list identified by nwIpxRipIfAclIdentifier. Enabled (3) applies the access control list to all IPX-RIP routing protocol packet traffic on the router port for which the entry exists. Disabled (2) prevents the access control list from being applied. " DEFVAL { disabled } ::= { nwIpxRipIfEntry 17 } -- IPX RIP Interface Counters Table -- This table contains the managed objects for IPX RIP packet and byte -- counter on a per router port basis. nwIpxRipIfCtrTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxRipIfCtrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry for each router port.This table is indexed by nwIpxRipIfCtrIfIndex, which indicates the value of MIB2 ifindex, which indentifies the router port for which the entry exists." ::= { nwIpxRipIfCounters 1 } nwIpxRipIfCtrEntry OBJECT-TYPE SYNTAX NwIpxRipIfCtrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry indicates the current packet and byte count of IPX-RIP routing protocol packets on the router port for which the entry exists." INDEX { nwIpxRipIfCtrIfIndex } ::= { nwIpxRipIfCtrTable 1 } NwIpxRipIfCtrEntry ::= SEQUENCE { nwIpxRipIfCtrIfIndex INTEGER, nwIpxRipIfCtrAdminStatus INTEGER, nwIpxRipIfCtrReset INTEGER, nwIpxRipIfCtrOperationalTime TimeTicks, nwIpxRipIfCtrInPkts Counter, nwIpxRipIfCtrOutPkts Counter, nwIpxRipIfCtrFilteredPkts Counter, nwIpxRipIfCtrDiscardPkts Counter, nwIpxRipIfCtrInBytes Counter, nwIpxRipIfCtrOutBytes Counter, nwIpxRipIfCtrFilteredBytes Counter, nwIpxRipIfCtrDiscardBytes Counter } nwIpxRipIfCtrIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the value of MIB 2 ifindex, which identifies the router port for which the entry exists." ::= { nwIpxRipIfCtrEntry 1 } nwIpxRipIfCtrAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the per-port IPX-RIP packet and byte counters on the router port for which the entry exists. Enabled (3) causes these counters to become active. Disabled (2) causes these counters to become inactive." DEFVAL { enabled } ::= { nwIpxRipIfCtrEntry 2 } nwIpxRipIfCtrReset OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the per-port IPX-RIP packet and byte counters on the router port for which this entry exists. Reset (2) resets the counters to 0. nwIpxRipIfCtrOperationalTime is also reset to 0." ::= { nwIpxRipIfCtrEntry 3 } nwIpxRipIfCtrOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that nwIpRipIfCtrAdminStatus has been in the current state." ::= { nwIpxRipIfCtrEntry 4 } nwIpxRipIfCtrInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX-RIP routing protocol packets that have been received, during nwIpxRipIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxRipIfCtrEntry 5 } nwIpxRipIfCtrOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX-RIP routing protocol packets that have been transmitted, during nwIpxRipIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxRipIfCtrEntry 6 } nwIpxRipIfCtrFilteredPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX-RIP routing protocol packets that have been administratively filtered, during nwIpxRipIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxRipIfCtrEntry 7 } nwIpxRipIfCtrDiscardPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX-RIP routing protocol packets that have been discarded, during nwIpxRipIfCtrOperationalTime, that were received on the router port for which the entry exists." ::= { nwIpxRipIfCtrEntry 8 } nwIpxRipIfCtrInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX-RIP routing protocol packets that have been received, during nwIpxRipIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxRipIfCtrEntry 9 } nwIpxRipIfCtrOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX-RIP routing protocol packets that have been transmitted, during nwIpxRipIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxRipIfCtrEntry 10 } nwIpxRipIfCtrFilteredBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX-RIP routing protocol packets that have been administratively filtered, during nwIpxRipIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxRipIfCtrEntry 11 } nwIpxRipIfCtrDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX-RIP routing protocol packets that have been discarded, during nwIpRipIfCtrOperationalTime, that were received on the router port for which the entry exists." ::= { nwIpxRipIfCtrEntry 12 } -- IPX RIP Routing Table -- This table contains the managed objects for IPX RIP route table. nwIpxRipRouteTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxRipRouteEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the IPX-RIP route table. This table contains an entry for each route learned through the IPX-RIP routing protocol. Only the best routes from this table are added to the IPX forwarding table to be used for packet switching." ::= { nwIpxRipDatabase 1 } nwIpxRipRouteEntry OBJECT-TYPE SYNTAX NwIpxRipRouteEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry describes the IPX-RIP route to the destination network for which the entry exists." INDEX { nwIpxRipRtNetId, nwIpxRipRtIfIndex, nwIpxRipRtSrcNode } ::= { nwIpxRipRouteTable 1 } NwIpxRipRouteEntry ::= SEQUENCE { nwIpxRipRtNetId IpxAddress, nwIpxRipRtIfIndex INTEGER, nwIpxRipRtSrcNode IpxAddress, nwIpxRipRtHops INTEGER, nwIpxRipRtTicks INTEGER, nwIpxRipRtAge INTEGER, nwIpxRipRtType INTEGER, nwIpxRipRtFlags INTEGER } nwIpxRipRtNetId OBJECT-TYPE SYNTAX IpxAddress ACCESS read-only STATUS mandatory DESCRIPTION "This is the primary index into the IPX-RIP route table. This number indicates the Novell Network Number of the destination for which the entry exists. The IpxAddress consists of a network number of 4 octets" ::= { nwIpxRipRouteEntry 1 } nwIpxRipRtIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is a secondary index into the IPX-RIP route table. This number corresponds to the value of MIB 2 ifindex, which identifies the router port for which the entry exists." ::= { nwIpxRipRouteEntry 2 } nwIpxRipRtSrcNode OBJECT-TYPE SYNTAX IpxAddress ACCESS read-only STATUS mandatory DESCRIPTION "This is a secondary index into the RIP route table. This number indicates the MAC-layer address of the source router from which this route was learned. A value of 0.0.0.0.0.0 indicates that the source is on the network segment directly connected to the router port, nwIpxRipRtIfIndex." ::= { nwIpxRipRouteEntry 3 } nwIpxRipRtHops OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of hops required to reach the destination for which the entry exists." ::= { nwIpxRipRouteEntry 4 } nwIpxRipRtTicks OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the amount of time (number of Time Ticks) required to reach the destination for which the entry exists." ::= { nwIpxRipRouteEntry 5 } nwIpxRipRtAge OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the amount of time, in seconds, since an update has been received for the route for which the entry exists." ::= { nwIpxRipRouteEntry 6 } nwIpxRipRtType OBJECT-TYPE SYNTAX INTEGER { other(1), invalid(2), direct(3), remote(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the destination network is directly connected through the router port specified by nwIpxRipRtIndex, or is indirectly connected through another router, specified by nwIpxRipRtSrcNode." ::= { nwIpxRipRouteEntry 7 } nwIpxRipRtFlags OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies properties of the IPX-RIP route. The bit mask is as follows: source-changed (1), best source (2), local-net (4), net-down (8), update-fib-only (16)." ::= { nwIpxRipRouteEntry 8 } -- IPX SAP System Group -- This group contains the managed object for global, device-wide -- IPX SAP DistanceVector based routing protocol. -- IPX SAP System Configuration Parameters -- This group contains the objects that pertain to the setup and -- configuration of the IPX SAP DistanceVector based routing protocol. nwIpxSapAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- shutdown the router enabled(3) -- startup the router } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the SAP protocol system-wide. Enabled (3) causes SAP to become active on all router ports configured and enabled for IPX routing services. Disabled (2) causes the protocol to become inactive." DEFVAL { disabled } ::= { nwIpxSapConfig 1 } nwIpxSapOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- not running enabled(3), -- running pending-disable(4), -- shut-down in progress pending-enable(5) -- start-up in progress } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current operating condition of the SAP protocol system-wide. The value of nwIpxSapOperStatus indicates any problem with your SAP configuration. A value of 6 indicates that regardless of the value of nwIpxSAPAdminStatus, the SAP protocol is not operating because of an invalid configuration." ::= { nwIpxSapConfig 2 } nwIpxSapAdminReset OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following reset(2) -- force a reset } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the SAP protocol. Reset (2) forces a system-wide restart of SAP, without a graceful shutdown on any active router ports." DEFVAL { other } ::= { nwIpxSapConfig 3 } nwIpxSapOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that nwIpxSapOperStatus, has been in its current state." ::= { nwIpxSapConfig 4 } nwIpxSapVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current revision level of the SAP protocol firmware, in textual format." ::= { nwIpxSapConfig 5 } nwIpxSapStackSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the stack size of the SAP protocol thread. In order for a change to this value to take effect, the protocol (nwIpxSapAdminReset), IPX Routing Services (nwIpxSysAdminReset), or the device running Routing Services must be reset." DEFVAL { 4096 } ::= { nwIpxSapConfig 6 } nwIpxSapThreadPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the run-time execution priority of the SAP protocol thread. In order for a change to this value to take effect, SAP (nwIpxSapAdminReset), IPX Routing Services (nwIpxAdminReset), or the device running Routing Services must be reset." DEFVAL { 127 } ::= { nwIpxSapConfig 7 } nwIpxSapDatabaseThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the run-time maximum number of entries that can be held in the SAP server table." DEFVAL { 2000 } ::= { nwIpxSapConfig 8 } nwIpxSapAgeOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the amount of time, in seconds, that an inactive server table entry remains in the SAP server table before it is aged out." DEFVAL { 180 } ::= { nwIpxSapConfig 9 } nwIpxSapHoldDown OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the amount of time, in seconds, to wait before removing an entry from the SAP server table, after receiving an update indicating that the destination has become unreachable. All routers exchanging SAP information must have the same hold down time. The time must be long enough to allow all participating routers to receive the same update." DEFVAL { 120 } ::= { nwIpxSapConfig 10 } -- IPX SAP System (aggregate) Counters -- This group contains the aggregate (device-wide) IPX SAP packet and -- byte counters. nwIpxSapCtrAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the aggregate (system-wide) SAP protocol packet and byte counters. Enabled (3) causes these counters to become active on all router ports. Disabled (2) causes these counters to become inactive." DEFVAL { enabled } ::= { nwIpxSapCounters 1 } nwIpxSapCtrReset OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the aggregate (system-wide) SAP protocol packet and byte counters. Reset (2) resets the SAP aggregate counters to 0. nwIpxSapCtrOperationalTime is also reset to 0." DEFVAL { other } ::= { nwIpxSapCounters 2 } nwIpxSapCtrOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that nwIpxSapCtrAdminStatus, has been in the current state." ::= { nwIpxSapCounters 3 } nwIpxSapCtrInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of SAP packets that have been received, system-wide, during nwIpxSapCtrOperationalTime." ::= { nwIpxSapCounters 4 } nwIpxSapCtrOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of SAP packets that have been transmitted, system-wide, during nwIpxSapCtrOperationalTime." ::= { nwIpxSapCounters 5 } nwIpxSapCtrFilteredPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of SAP packets that have been administratively filtered, system-wide, during nwIpxSapCtrOperationalTime." ::= { nwIpxSapCounters 6 } nwIpxSapCtrDiscardPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of SAP packets that have been discarded, system-wide, during nwIpxSapCtrOperationalTime." ::= { nwIpxSapCounters 7 } nwIpxSapCtrInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the SAP packets that have been received, system-wide, during nwIpxSapCtrOperationalTime." ::= { nwIpxSapCounters 8 } nwIpxSapCtrOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the SAP packets that have been transmitted, system-wide, during nwIpxSapCtrOperationalTime." ::= { nwIpxSapCounters 9 } nwIpxSapCtrFilteredBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the SAP packets that have been administratively filtered, system-wide, during nwIpxSapCtrOperationalTime." ::= { nwIpxSapCounters 10 } nwIpxSapCtrDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the SAP packets that have been discarded system-wide, during nwIpxSapCtrOperationalTime." ::= { nwIpxSapCounters 11 } -- IPX SAP Interface Table -- This table contains the managed objects used to setup and configure -- SAP on a per router port basis. nwIpxSapIfTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxSapIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry for each router port. Each entry can contain different values, allowing the SAP configuration to vary from router port to router port. This table is indexed by nwIpxSapIfIndex, which indicates the value of MIB 2 ifindex, which identifies the router port for which each entry exists." ::= { nwIpxSapIfConfig 1 } nwIpxSapIfEntry OBJECT-TYPE SYNTAX NwIpxSapIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the SAP configuration for the router port for which the entry exists." INDEX { nwIpxSapIfIndex } ::= { nwIpxSapIfTable 1 } NwIpxSapIfEntry ::= SEQUENCE { nwIpxSapIfIndex INTEGER, nwIpxSapIfAdminStatus INTEGER, nwIpxSapIfOperStatus INTEGER, nwIpxSapIfOperationalTime TimeTicks, nwIpxSapIfVersion INTEGER, nwIpxSapIfAdvertisement INTEGER, nwIpxSapIfFloodDelay INTEGER, nwIpxSapIfRequestDelay INTEGER, nwIpxSapIfPriority INTEGER, nwIpxSapIfHelloTimer INTEGER, nwIpxSapIfSplitHorizon INTEGER, nwIpxSapIfPoisonReverse INTEGER, nwIpxSapIfSnooping INTEGER, nwIpxSapIfType INTEGER, nwIpxSapIfXmitCost INTEGER, nwIpxSapIfAclIdentifier INTEGER, nwIpxSapIfAclStatus INTEGER } nwIpxSapIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the value of MIB 2 ifindex, which identifies the router port for which the entry exists." ::= { nwIpxSapIfEntry 1 } nwIpxSapIfAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the SAP protocol on the router port for which the entry exists. Enabled (3) causes SAP to become active on the router port. Disabled (2) causes SAP to become inactive." DEFVAL { disabled } ::= { nwIpxSapIfEntry 2 } nwIpxSapIfOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- not running enabled(3), -- running pending-disable(4), -- shut-down in progress pending-enable(5) -- start-up in progress } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current operating condition of the SAP protocol on the router port for which the entry exists. The value of nwIpxSapIfOperStatus indicates any problem with your SAP configuration on the router port. A value of 6 indicates that regardless of the value of nwIpxSapIfAdminStatus. SAP is not operating because of an invalid configuration." ::= { nwIpxSapIfEntry 3 } nwIpxSapIfOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that nwIpxSapIfOperStatus has been in its current state." ::= { nwIpxSapIfEntry 4 } nwIpxSapIfVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the revision level of the SAP protocol in textual format." DEFVAL { 1 } ::= { nwIpxSapIfEntry 5 } nwIpxSapIfAdvertisement OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Sets the interval, in seconds, at which SAP advertises its server table on the router port for which the entry exists. Change this value to cause SAP to advertise its server table more or less frequently." DEFVAL { 60 } ::= { nwIpxSapIfEntry 6 } nwIpxSapIfFloodDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the length of time, in seconds, that the SAP protocol will wait after discovering that a directly connected route has gone down, before flooding updates (triggered updates) on the router port for which the entry exists. A value of 0 specifies that if a directly connected route goes down, updates should be sent immediately ." DEFVAL { 2 } ::= { nwIpxSapIfEntry 7 } nwIpxSapIfRequestDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the length of time, in seconds, that the SAP protocol will wait after receiving a server request packet, before sending a response on the router port for which the entry exists. A value of 0 specifies that if a server request packet is received on the port, a response will be sent immediately." DEFVAL { 0 } ::= { nwIpxSapIfEntry 8 } nwIpxSapIfPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a management interface to all the Cabletron Routing Services protocol-specific MIBs. Setting this object has no effect." DEFVAL { 1 } ::= { nwIpxSapIfEntry 9 } nwIpxSapIfHelloTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a management interface to all the Cabletron Routing Services protocol-specific MIBs.Setting this object has no effect." DEFVAL { 10 } ::= { nwIpxSapIfEntry 10 } nwIpxSapIfSplitHorizon OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls the operation of Split Horizon on the router port for which the entry exists. When Split Horizon is enabled, SAP keeps track of which router port information is received on, and prevents information about a server from being sent back out the same router port it was received on." DEFVAL { enabled } ::= { nwIpxSapIfEntry 11 } nwIpxSapIfPoisonReverse OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls the operation of Poison Reverse on the router port for which the entry exists. When Poison Reverse is enabled, SAP advertises any downed server as unreachable during the period of time that it must wait (nwIpxSapIfHoldDown) before removing the server from the server table." DEFVAL { disabled } ::= { nwIpxSapIfEntry 12 } nwIpxSapIfSnooping OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls the operation of SAP Snooping on the router port. When SAP Snooping is enabled SAP operates in passive mode, so it receives service information, builds and maintains a server table, but does not advertise or send updates on the router port for which the entry exists. Enabled (3) turns on SAP Snooping. Disabled (2) turns off SAP Snooping." DEFVAL { disabled } ::= { nwIpxSapIfEntry 13 } nwIpxSapIfType OBJECT-TYPE SYNTAX INTEGER { other(1), bma(2), nbma(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the directly connected network segment does or does not support broadcast media access. If broadcast media access is supported, SAP advertisements are sent out, one broadcast packet per router port. If broadcast media access is not supported, SAP advertisements are sent to each neighbor router directly." DEFVAL { bma } ::= { nwIpxSapIfEntry 14 } nwIpxSapIfXmitCost OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs. Setting this object has no effect." DEFVAL { 0 } ::= { nwIpxSapIfEntry 15 } nwIpxSapIfAclIdentifier OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the Access Control List ID of the access control list in effect for SAP protocol packets on the router port for which the entry exists. A value of 0 indicates that there is no access control list in effect for SAP protocol packets on the router port for which the entry exists." DEFVAL { 0 } ::= { nwIpxSapIfEntry 16 } nwIpxSapIfAclStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls the operation of the access control list identified by nwIpxSapIfAclIdentifier. Enabled (3) causes the access control list to be applied to all SAP protocol packet traffic on the router port for which the entry exists. Disabled (2) prevents the access control list from being applied." DEFVAL { disabled } ::= { nwIpxSapIfEntry 17 } -- IPX SAP Interface Counters Table -- This table contains the managed objects for IPX SAP packet and byte -- counter on a per router port basis. nwIpxSapIfCtrTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxSapIfCtrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry for each router port. This table is indexed by nwIpxSapIfCtrIfIndex which indicates the value of MIB2 ifindex, which indentifies the router port for which the entry exists." ::= { nwIpxSapIfCounters 1 } nwIpxSapIfCtrEntry OBJECT-TYPE SYNTAX NwIpxSapIfCtrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry indicates the current packet and byte count of SAP protocol packets on the router port for which the entry exists." INDEX { nwIpxSapIfCtrIfIndex } ::= { nwIpxSapIfCtrTable 1 } NwIpxSapIfCtrEntry ::= SEQUENCE { nwIpxSapIfCtrIfIndex INTEGER, nwIpxSapIfCtrAdminStatus INTEGER, nwIpxSapIfCtrReset INTEGER, nwIpxSapIfCtrOperationalTime TimeTicks, nwIpxSapIfCtrInPkts Counter, nwIpxSapIfCtrOutPkts Counter, nwIpxSapIfCtrFilteredPkts Counter, nwIpxSapIfCtrDiscardPkts Counter, nwIpxSapIfCtrInBytes Counter, nwIpxSapIfCtrOutBytes Counter, nwIpxSapIfCtrFilteredBytes Counter, nwIpxSapIfCtrDiscardBytes Counter } nwIpxSapIfCtrIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the value of the MIB 2 ifindex, which identifies the router port for which the entry exists." ::= { nwIpxSapIfCtrEntry 1 } nwIpxSapIfCtrAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the per-port SAP packet and byte counters on the router port for which this entry exists. Enabled (3) causes these counters to become active. Disabled (2) causes these counters to become inactive." DEFVAL { enabled } ::= { nwIpxSapIfCtrEntry 2 } nwIpxSapIfCtrReset OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the per-port SAP packet and byte counters on the router port for which the entry exists. Reset (2) resets the counters to 0. nwIpxSapIfCtrOperationalTime is also reset to 0." DEFVAL { other } ::= { nwIpxSapIfCtrEntry 3 } nwIpxSapIfCtrOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that nwIpxSapIfCtrAdminStatus has been in the current state." ::= { nwIpxSapIfCtrEntry 4 } nwIpxSapIfCtrInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of SAP protocol packets that have been received, during nwIpxSapIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxSapIfCtrEntry 5 } nwIpxSapIfCtrOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of SAP packets that have been transmitted, during nwIpxSapIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxSapIfCtrEntry 6 } nwIpxSapIfCtrFilteredPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of SAP packets that have been administratively filtered, during nwIpxSapIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxSapIfCtrEntry 7 } nwIpxSapIfCtrDiscardPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of SAP packets that have been discarded, during nwIpxSapIfCtrOperationalTime, that were received on the router port for which the entry exists." ::= { nwIpxSapIfCtrEntry 8 } nwIpxSapIfCtrInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the SAP packets that have been received, during nwIpxSapIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxSapIfCtrEntry 9 } nwIpxSapIfCtrOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the SAP packets that have been transmitted, during nwIpxSapIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxSapIfCtrEntry 10 } nwIpxSapIfCtrFilteredBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the SAP packets that have been administratively filtered, during nwIpxSapIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwIpxSapIfCtrEntry 11 } nwIpxSapIfCtrDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the SAP packets that have been discarded, during nwIpxSapIfCtrOperationalTime, that were received on the router port for which the entry exists." ::= { nwIpxSapIfCtrEntry 12 } -- IPX SAP Server table Table -- This table contains the managed objects for IPX SAP route table. nwIpxSapServerIfTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxSapServerIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table contains the SAP server table. This table contains an entry for each service learned of through the SAP protocol." ::= { nwIpxSapServerTable 1 } nwIpxSapServerIfEntry OBJECT-TYPE SYNTAX NwIpxSapServerIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the SAP route information for the Novell server and router port for which the entry exists." INDEX { nwIpxSapServerIfNetId, nwIpxSapServerIfNode, nwIpxSapServerIfSocket, nwIpxSapServerIfServiceType, nwIpxSapServerIfIfNum, nwIpxSapServerIfSrcNode } ::= { nwIpxSapServerIfTable 1 } NwIpxSapServerIfEntry ::= SEQUENCE { nwIpxSapServerIfNetId IpxAddress, nwIpxSapServerIfNode OCTET STRING, nwIpxSapServerIfSocket OCTET STRING, nwIpxSapServerIfServiceType INTEGER, nwIpxSapServerIfIfNum INTEGER, nwIpxSapServerIfSrcNode OCTET STRING, nwIpxSapServerIfName OCTET STRING, nwIpxSapServerIfHops INTEGER, nwIpxSapServerIfAge INTEGER, nwIpxSapServerIfType INTEGER, nwIpxSapServerIfFlags INTEGER } nwIpxSapServerIfNetId OBJECT-TYPE SYNTAX IpxAddress ACCESS read-only STATUS mandatory DESCRIPTION "This is the primary index into the SAP server table. This number corresponds to the Novell Network Number of the server offering the service. The network number consists of 4 octets." ::= { nwIpxSapServerIfEntry 1 } nwIpxSapServerIfNode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This is a secondary index into the SAP Server Table. This is the MAC-layer address represented as an octetstring of the service offering the server for which the entry exists, represented as an octet string." ::= { nwIpxSapServerIfEntry 2 } nwIpxSapServerIfSocket OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This is a secondary index into the SAP Server Table. This is the socket number of the server application for which the entry exists." ::= { nwIpxSapServerIfEntry 3 } nwIpxSapServerIfServiceType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is a secondary index into the SAP Server Table. This is the service type of the server application for which the entry exists." ::= { nwIpxSapServerIfEntry 4 } nwIpxSapServerIfIfNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the value of MIB 2 ifindex, which identifies the router port through which the service for which the entry exits is available." ::= { nwIpxSapServerIfEntry 5 } nwIpxSapServerIfSrcNode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This is the MAC-layer address of the neighbor router from which the service was learned about." ::= { nwIpxSapServerIfEntry 6 } nwIpxSapServerIfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This is the name of the server offering the service for which the entry exists." ::= { nwIpxSapServerIfEntry 7 } nwIpxSapServerIfHops OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of hops required to reach the server offering the service for which the entry exists." ::= { nwIpxSapServerIfEntry 8 } nwIpxSapServerIfAge OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the amount of time since a SAP update was last received for the server and service for which the entry exits." ::= { nwIpxSapServerIfEntry 9 } nwIpxSapServerIfType OBJECT-TYPE SYNTAX INTEGER { other(1), invalid(2), direct(3), remote(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the server is on a network that is directly connected through the router port for which the entry exists, or is indirectly connected through another router specified by the value of nwIpxSapServerIfSrcNode." ::= { nwIpxSapServerIfEntry 10 } nwIpxSapServerIfFlags OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies properties of the SAP service for which the entry exist. The bit mask is as follows: source-changed (1), best-source (2), not used (4), net-down (8), not used (16)." ::= { nwIpxSapServerIfEntry 11 } -- IPX Forward Information Base (FIB) Table -- This table contains the managed objects for the forwarding table of the -- IPX router. This table is built from entries in the IPX routing table(s) -- and reflects the routes that are considered the best routes to forward on. nwIpxFibTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxFibEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry describing each route being used to forward IPX traffic to each destination Novell network and node." ::= { nwIpxFib 1 } nwIpxFibEntry OBJECT-TYPE SYNTAX NwIpxFibEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry describes the route to the destination Novell network and node for which the entry exists." INDEX { nwIpxFibNetId } ::= { nwIpxFibTable 1 } NwIpxFibEntry ::= SEQUENCE { nwIpxFibNetId IpxAddress, nwIpxFibHops INTEGER, nwIpxFibTimeTicks TimeTicks, nwIpxFibNextHopIf INTEGER, nwIpxFibNextHopNet OCTET STRING, nwIpxFibNextHopNode MacAddress, nwIpxFibRouteType INTEGER } nwIpxFibNetId OBJECT-TYPE SYNTAX IpxAddress ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the Novell Network Number of the destination for which the entry exists. The IpxAddress consists of four octets" ::= { nwIpxFibEntry 1 } nwIpxFibHops OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the number of hops required to reach the destination for which the entry exists. It is considered as metric 1." DEFVAL { 0 } ::= { nwIpxFibEntry 2 } nwIpxFibTimeTicks OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the amount of time, indicated by the number of TimeTicks, required for a packet to reach the destination network for which the entry exists. It is considered as metric 2." DEFVAL { 0 } ::= { nwIpxFibEntry 3 } nwIpxFibNextHopIf OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the router port through which the next hop node is available. Packets destined for the network specified by the value of nwIpxFibNetId will be forwarded on this port." ::= { nwIpxFibEntry 4 } nwIpxFibNextHopNet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the Novell Network Number portion of the fully formed next hop IPX Address of the next hop node." ::= { nwIpxFibEntry 5 } nwIpxFibNextHopNode OBJECT-TYPE SYNTAX MacAddress ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the node portion of the fully formed next hop IPX Address." ::= { nwIpxFibEntry 6 } nwIpxFibRouteType OBJECT-TYPE SYNTAX INTEGER { other(1), invalid(2), direct(3), remote(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the status of the route. A value of 3 indicates that the destination is on the network segment that is directly connected to the router port identified by nwIpxFibNextHopIf. A value of 4 indicates that the destination is on an indirectly connected network segment, which is reachable through the next hop router indicated by the value of nwIpxFibNextHopNodeId. A value of 2 indicates that the route is invalid." DEFVAL { direct } ::= { nwIpxFibEntry 7 } -- IPX Access Control List Table -- This table contains the managed objects for the Access Control Lists -- within the IPX Router. Access Control Lists allow configuration of -- restricted access to networks and protocols reachable thru the IPX -- Router device. Access Control Lists can be defined with these nwIpxAclValidEntries OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of valid entries that exist in the access control list table." ::= { nwIpxAccessControl 1 } nwIpxAclTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxAclEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the access control list information for IPX traffic. This table contains entries, each of which allows packet forwarding between source/destination pairs to be permitted or denied. The list is identified by the Access Control List ID. Each list may contain multiple entries ordered by sequence number. When a particular access control list is searched, it is searched in sequence number order and the first match found ends the search. If no match if found, access defaults to permitted." ::= { nwIpxAccessControl 2 } nwIpxAclEntry OBJECT-TYPE SYNTAX NwIpxAclEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains IPX source/destination access information." INDEX { nwIpxAclIdentifier, nwIpxAclSequence } ::= { nwIpxAclTable 1 } NwIpxAclEntry ::= SEQUENCE { nwIpxAclIdentifier INTEGER, nwIpxAclSequence INTEGER, nwIpxAclPermission INTEGER, nwIpxAclMatches Counter, nwIpxAclDestNetNum OCTET STRING, nwIpxAclDestNode OCTET STRING, nwIpxAclDestSocket OCTET STRING, nwIpxAclSrcNetNum OCTET STRING, nwIpxAclSrcNode OCTET STRING, nwIpxAclSrcSocket OCTET STRING } nwIpxAclIdentifier OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the primary (major) index into the IPX access control list table. This value identifies the access control list by a unique identifier (at least 1) arbitrarily assigned by the user. All entries that have the same value for nwIpxAclIdentifier belong to the same access control list." ::= { nwIpxAclEntry 1 } nwIpxAclSequence OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the secondary (minor) index into the IPX access control list table. This number corresponds to a sequence number used to order multiple entries within the same access control list." ::= { nwIpxAclEntry 2 } nwIpxAclPermission OBJECT-TYPE SYNTAX INTEGER { other(1), invalid(2), permit(3), deny(4), permit-bidirectional(5), deny-bidirectional(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether access is allowed or denied between the source and destination address pair. Note that source and destination are interchangeable when bi-directional control is selected. To remove an existing entry set nwIpxAclPermission to invalid (2). Invalid entries disappear after reboot." DEFVAL { permit } ::= { nwIpxAclEntry 3 } nwIpxAclMatches OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of matches on this entry that have resulted in the permit/deny access restriction being applied as part of the forwarding process." ::= { nwIpxAclEntry 4 } nwIpxAclDestNetNum OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the destination Novell Network Number used to compare for matches on the access control list. A 0 value is a wildcard which matches any Novell Network Number." ::= { nwIpxAclEntry 5 } nwIpxAclDestNode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the MAC-layer address of the destination node (represented as an octet string), used to compare for matches on the access control list. A value 0 is a wildcard, which matches any node." ::= { nwIpxAclEntry 6 } nwIpxAclDestSocket OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the socket number of the destination socket used to compare for matches on the access control list. A 0 value is a wildcard matching any socket." ::= { nwIpxAclEntry 7 } nwIpxAclSrcNetNum OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the Novell Network Number of the source Novell Network used to compare for matches on the access control list. A 0 value is a wildcard matching any Novell Network Number." ::= { nwIpxAclEntry 8 } nwIpxAclSrcNode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the MAC-layer address of the source node (represented as an octet string), used to compare for matches on the Access Control List. A 0 value is a wildcard matching any node." ::= { nwIpxAclEntry 9 } nwIpxAclSrcSocket OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the socket number of the source socket to compare for matches on the Access Control List. A 0 value is a wildcard matching any socket." ::= { nwIpxAclEntry 10 } -- IPX Redirector Group -- IPX NetBIOS System Group -- In order for NetBIOS to function, an IPX routing service is provided -- which allows NetBIOS traffic to be flooded out all router ports with -- NetBIOS enabled. nwIpxNetBIOSAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the NetBIOS Broadcast Redirector, system-wide. Enabled (3) causes the NetBios Broadcast Redirector to become active on any router port configured and enabled for IPX Routing Services. Disabled (2) causes the NetBIOS Broadcast Redirector to perform a graceful shut-down on any active IPX router port." DEFVAL { disabled } ::= { nwIpxNetBIOSConfig 1 } nwIpxNetBIOSOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- not running enabled(3), -- running pending-disable(4), -- shut-down in progress pending-enable(5), -- start-up in progress invalid-config(6) -- not running,invalid config } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current operating condition of the NetBIOS Broadcast Redirector, system-wide. " ::= { nwIpxNetBIOSConfig 2 } nwIpxNetBIOSAdminReset OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following reset(2) -- force a reset } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the NetBIOS Broadcast Redirector, system-wide. Reset (2) forces a restart of the NetBIOS Broadcast Redirector without a graceful shut-down on any active router port and without effecting any other router application." DEFVAL { other } ::= { nwIpxNetBIOSConfig 3 } nwIpxNetBIOSOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that nwIpxNetBiosOperStatus has been in the current state." ::= { nwIpxNetBIOSConfig 4 } nwIpxNetBIOSVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current revision level of the NetBIOS Broadcast Redirector firmware, in textual format." ::= { nwIpxNetBIOSConfig 5 } -- IPX NetBIOS System (aggregate) Counters -- This group contains the aggregate (device-wide) IPX NetBIOS packet -- and byte counters. nwIpxNetBIOSCtrAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the aggregate (system-wide) NetBIOS broadcast packet and byte counters. Enabled (3) causes these counters to become active on all router port. Disabled (2) causes these counters to become inactive." ::= { nwIpxNetBIOSCounters 1 } nwIpxNetBIOSCtrReset OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the aggregate (system-wide) NetBIOS broadcast packet and byte counters. Reset (2) resets the NetBIOS broadcast aggregate counters to 0. nwIpxNetBIOSCtrOperationalTime is also reset to 0." ::= { nwIpxNetBIOSCounters 2 } nwIpxNetBIOSCtrOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundreds of a second, that the nwIpxNetBIOSCtrAdminStatus has been in the current state." ::= { nwIpxNetBIOSCounters 3 } nwIpxNetBIOSCtrInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of NetBIOS broadcast packets that have been received, system-wide, during nwIpxNetBIOSCtrOperationalTime." ::= { nwIpxNetBIOSCounters 4 } nwIpxNetBIOSCtrOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of NetBIOS broadcast packets that have been transmitted, system-wide, during nwIpxNetBIOSCtrOperationalTime." ::= { nwIpxNetBIOSCounters 5 } nwIpxNetBIOSCtrFilteredPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of NetBIOS broadcast packets that have been administratively filtered, system-wide, during nwIpxNetBIOSCtrOperationalTime." ::= { nwIpxNetBIOSCounters 6 } nwIpxNetBIOSCtrDiscardPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of NetBIOS broadcast packets that have been discarded, system-wide, during nwIpxNetBIOSCtrOperationalTime." ::= { nwIpxNetBIOSCounters 7 } nwIpxNetBIOSCtrInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the NetBIOS packets that have been received, system-wide, during nwIpxNetBIOSCtrOperationalTime." ::= { nwIpxNetBIOSCounters 8 } nwIpxNetBIOSCtrOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the NetBIOS packets that have been transmitted, system-wide, during nwIpxNetBIOSCtrOperationalTime." ::= { nwIpxNetBIOSCounters 9 } nwIpxNetBIOSCtrFilteredBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the NetBIOS packets that have been administratively filtered, system-wide, during nwIpxNetBIOSCtrOperationalTime." ::= { nwIpxNetBIOSCounters 10 } nwIpxNetBIOSCtrDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the NetBIOS packets that have been discarded, system-wide, during nwIpxNetBIOSCtrOperationalTime." ::= { nwIpxNetBIOSCounters 11 } -- IPX NetBIOS Interface Table -- This table contains the managed objects used to setup and configure -- NetBIOS on a per router port basis. nwIpxNetBIOSIfTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxNetBIOSIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry for each router port. Each entry can contain different values, allowing the NetBIOS Broadcast Redirector configuration to vary from router port to router port. This table is indexed by nwIpxNetBIOSIfIndex, which indicates the value of MIB 2 ifindex, which identifies the router port for which the entry exists." ::= { nwIpxNetBIOSIfConfig 1 } nwIpxNetBIOSIfEntry OBJECT-TYPE SYNTAX NwIpxNetBIOSIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the IPX NetBIOS broadcasting configuration for the router port for which the entry exists." INDEX { nwIpxNetBIOSIfIndex } ::= { nwIpxNetBIOSIfTable 1 } NwIpxNetBIOSIfEntry ::= SEQUENCE { nwIpxNetBIOSIfIndex INTEGER, nwIpxNetBIOSIfAdminStatus INTEGER, nwIpxNetBIOSIfOperStatus INTEGER, nwIpxNetBIOSIfOperationalTime TimeTicks } nwIpxNetBIOSIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the value in MIB 2 ifindex, which identifies the router port for which the entry exists." ::= { nwIpxNetBIOSIfEntry 1 } nwIpxNetBIOSIfAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of IPX NetBIOS broadcasting on the router port for which the entry exists. Enabled (3) causes this router port to become active. Disabled (2) causes it to become inactive." DEFVAL { disabled } ::= { nwIpxNetBIOSIfEntry 2 } nwIpxNetBIOSIfOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- not running enabled(3), -- running pending-disable(4), -- shut-down in progress pending-enable(5), -- start-up in progress invalid-config(6) -- not running,invalid config } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current operating condition of IPX NetBIOS broadcasting on the IPX router port for which the entry exists." ::= { nwIpxNetBIOSIfEntry 3 } nwIpxNetBIOSIfOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that IPX NetBIOS broadcasting, nwIpxNetBIOSIfOperStatus, has been in its current state on the router port for which the entry exists." ::= { nwIpxNetBIOSIfEntry 4 } -- IPX NetBIOS Interface Counters Table -- This table contains the managed objects for IPX NetBIOS packet and -- byte counter on a per router port basis nwIpxNetBIOSIfCtrTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxNetBIOSIfCtrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the IPX NetBIOS packet and byte counters for each router port on this device." ::= { nwIpxNetBIOSIfCounters 1 } nwIpxNetBIOSIfCtrEntry OBJECT-TYPE SYNTAX NwIpxNetBIOSIfCtrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is the primary index into the NetBIOS Interface Counter Table. This number corresponds to the index into the MIB 2 Interface Table which describes the router port for which this entry exists." INDEX { nwIpxNetBIOSIfCtrIfIndex } ::= { nwIpxNetBIOSIfCtrTable 1 } NwIpxNetBIOSIfCtrEntry ::= SEQUENCE { nwIpxNetBIOSIfCtrIfIndex INTEGER, nwIpxNetBIOSIfCtrAdminStatus INTEGER, nwIpxNetBIOSIfCtrReset INTEGER, nwIpxNetBIOSIfCtrOperationalTime TimeTicks, nwIpxNetBIOSIfCtrInPkts Counter, nwIpxNetBIOSIfCtrOutPkts Counter, nwIpxNetBIOSIfCtrFilteredPkts Counter, nwIpxNetBIOSIfCtrDiscardPkts Counter, nwIpxNetBIOSIfCtrInBytes Counter, nwIpxNetBIOSIfCtrOutBytes Counter, nwIpxNetBIOSIfCtrFilteredBytes Counter, nwIpxNetBIOSIfCtrDiscardBytes Counter } nwIpxNetBIOSIfCtrIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the primary index into the IPX NetBIOS Interface Counter Table. This number correspoonds to the index into the MIB 2 Interface Table which describes the router port for which the entry exists." ::= { nwIpxNetBIOSIfCtrEntry 1 } nwIpxNetBIOSIfCtrAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the IPX NetBIOS packet and bytes counters on the IPX router port for which the entry exists. Enabled (3) causes these counters to become active on the configured NetBIOS router port. Disabled (2) causes thes counters to become inactive on the configured NetBIOS router port." ::= { nwIpxNetBIOSIfCtrEntry 2 } nwIpxNetBIOSIfCtrReset OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the NetBIOS packet and bvyte counters on the router port for which the entry exists. Reset (2) resets the interface-specific counters to 0. nwIpxNetBIOSIfCtrOperationalTime is also reset to 0." ::= { nwIpxNetBIOSIfCtrEntry 3 } nwIpxNetBIOSIfCtrOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the amount of time, in hundredths of a second, that the interface-specific NetBIOS packet and byte counters have been active on the router port for which the entry exists." ::= { nwIpxNetBIOSIfCtrEntry 4 } nwIpxNetBIOSIfCtrInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of NetBIOS packets that have been recieved, on the router port for which the entry exists, during nwIpxNetBIOSIfCtrOperationalTime." ::= { nwIpxNetBIOSIfCtrEntry 5 } nwIpxNetBIOSIfCtrOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of NetBIOS packets that have been transmitted, on the router port for which the entry exists, during nwIpxNetBIOSIfCtrOperationallTime." ::= { nwIpxNetBIOSIfCtrEntry 6 } nwIpxNetBIOSIfCtrFilteredPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of NetBIOS packets that have been administratively filtered, on the router port for which the entry exists, during nwIpxNetBIOSIfCtrOperationalTime." ::= { nwIpxNetBIOSIfCtrEntry 7 } nwIpxNetBIOSIfCtrDiscardPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of NetBIOS packets that have been discarded, on the router port for which the entry exists, during nwIpxNetBIOSIfCtrOperationalTime." ::= { nwIpxNetBIOSIfCtrEntry 8 } nwIpxNetBIOSIfCtrInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the NetBIOS packets that have been recieved, on the router port for which the entry exists, during nwIpxNetBIOSIfCtrOperationalTime." ::= { nwIpxNetBIOSIfCtrEntry 9 } nwIpxNetBIOSIfCtrOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the NetBIOS packets that have been transmitted, on the router port for which the entry exists, during nwIpxNetBIOSIfCtrOperationalTime." ::= { nwIpxNetBIOSIfCtrEntry 10 } nwIpxNetBIOSIfCtrFilteredBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the NetBIOS packets that have been administratively filtered, that were recieved on the router port for which the entry exists during nwIpxNetBIOSIfCtrOperationalTime." ::= { nwIpxNetBIOSIfCtrEntry 11 } nwIpxNetBIOSIfCtrDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the NetBIOS packets that have been discarded, on the router port for which the entry exists, during nwIpxNetBIOSIfCtrOperationalTime." ::= { nwIpxNetBIOSIfCtrEntry 12 } -- IPX Broadcast System Group -- IPX Broadcast support allows broadcast packets that would normally be -- delivered to the host to also be switched out the proper router port -- if that router port has broadcast enabled. The router port is determined -- by the destination network number in the broadcast packet. nwIpxBcastAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- shutdown the router enabled(3) -- startup the router } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of IPX Broadcast. Enabled (3) casuses IPX Broadcast to become active on any configured IPX router port. Disabled (2) causes IPX Broadcast to perform a graceful shutdown on any active IPX router ports." DEFVAL { disabled } ::= { nwIpxBroadcastConfig 1 } nwIpxBcastOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- not running enabled(3), -- running pending-disable(4), -- shut-down in progress pending-enable(5), -- start-up in progress invalid-config(6) -- not running,invalid config } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current operating condition of the IPX Broadcast." ::= { nwIpxBroadcastConfig 2 } nwIpxBcastAdminReset OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following reset(2) -- force a reset } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the IPX Broadcast. Reset (2) will force a restart of the IPX Broadcast without a graceful shutdown on any active IPX router port, without effecting any other router applications." DEFVAL { other } ::= { nwIpxBroadcastConfig 3 } nwIpxBcastOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the amount of time, in hundredths of a second, that IPX Broadcast has been in its current operational state." ::= { nwIpxBroadcastConfig 4 } nwIpxBcastVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current revision level of IPX Broadcast." ::= { nwIpxBroadcastConfig 5 } -- IPX Broadcast System (aggregate) Counters -- This group contains the aggregate (device-wide) IPX Broadcast packet -- and byte counters. nwIpxBcastCtrAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the aggregate (device-wide) Broadcast packet and byte counters. enable (3) causes these counters to become active on any router port running Broadcast. disabled (2) causes these counters to become inactive on all router port running Broadcast." ::= { nwIpxBroadcastCounters 1 } nwIpxBcastCtrReset OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the aggregate (device-wide) IPX Broadcast packet and byte counters. Reset (2) resets the IPX Broadcast aggregate counters to 0. nwIpxBcasstCtrOperationalTime is also reset to 0." ::= { nwIpxBroadcastCounters 2 } nwIpxBcastCtrOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the amount of time, in hundredths of a second, that the aggregate (device-wide) IPX Broadcast packet and byte counters have been in the current administrative state." ::= { nwIpxBroadcastCounters 3 } nwIpxBcastCtrInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX Broadcast packets that have been received, device-wide, during nwIpxBcastCtrOperationalTime." ::= { nwIpxBroadcastCounters 4 } nwIpxBcastCtrOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX Broadcast packets that have been transmitted, device-wide, during nwIpxBcastCtrOperationalTime." ::= { nwIpxBroadcastCounters 5 } nwIpxBcastCtrFilteredPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX Broadcast packets that have been administaratively filtered, device-wide, during nwIpxBcastCtrOperationalTime." ::= { nwIpxBroadcastCounters 6 } nwIpxBcastCtrDiscardPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX Broadcast packets that have been discarded, device-wide, during nwIpxBcastCtrOperationalTime." ::= { nwIpxBroadcastCounters 7 } nwIpxBcastCtrInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX Broadcast packets that have been recieved, device-wide, during nwIpxBcastCtrOperationalTime." ::= { nwIpxBroadcastCounters 8 } nwIpxBcastCtrOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX Broadcast packets that have been transmitted, device-wide, during nwIpxBcastCtrOperationalTime." ::= { nwIpxBroadcastCounters 9 } nwIpxBcastCtrFilteredBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX Broadcast packets that have been administratively filtered, device-wide, during nwIpxBcastOperationalTime." ::= { nwIpxBroadcastCounters 10 } nwIpxBcastCtrDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the Broadcast packets that have been discarded, during nwIpxBcastCtrOperationalTime." ::= { nwIpxBroadcastCounters 11 } -- IPX Broadcast Interface Table -- This table contains the managed objects used to setup and configure -- Broadcast on a per router port basis. nwIpxBcastIfTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxBcastIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry for each router port configured for the IPX distance-vector based routing protocol. Each entry can contain different values, allowing the routing protocol configuration to vary from router port to router port. This table is indexed by nwIpxBcastIfIndex, which indicates the value of MIB 2 ifindex, which identifies the router port for which the entry exists." ::= { nwIpxBroadcastIfConfig 1 } nwIpxBcastIfEntry OBJECT-TYPE SYNTAX NwIpxBcastIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Specifies the IPX Broadcast configuration information for the logical IPX interface for which this entry exists." INDEX { nwIpxBcastIfIndex } ::= { nwIpxBcastIfTable 1 } NwIpxBcastIfEntry ::= SEQUENCE { nwIpxBcastIfIndex INTEGER, nwIpxBcastIfAdminStatus INTEGER, nwIpxBcastIfOperStatus INTEGER, nwIpxBcastIfOperationalTime TimeTicks } nwIpxBcastIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This index corresponds to the primary index into the MIB 2 Interface Table, which describes the router port for which the entry exists." ::= { nwIpxBcastIfEntry 1 } nwIpxBcastIfAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the IPX Broadcast on the router port for which the entry exists. Enabled (2) causes IPX Broadcast on this router port to become active. Disabled (2) causes IPX Broadcast to become inactive." DEFVAL { disabled } ::= { nwIpxBcastIfEntry 2 } nwIpxBcastIfOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- not running enabled(3), -- running pending-disable(4), -- shut-down in progress pending-enable(5), -- start-up in progress invalid-config(6) -- not running,invalid config } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current operating condition of the IPX Broadcast on the router port for which the entry exists." ::= { nwIpxBcastIfEntry 3 } nwIpxBcastIfOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that nwIPXBcastIfOperStatus has been in its current state." ::= { nwIpxBcastIfEntry 4 } -- IPX Broadcast Interface Counters Table -- This table contains the managed objects for IPX Broadcast packet and -- byte counter on a per router port basis. nwIpxBcastIfCtrTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxBcastIfCtrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the IPX Broadcast packet and byte counters for each router port on this device." ::= { nwIpxBroadcastIfCounters 1 } nwIpxBcastIfCtrEntry OBJECT-TYPE SYNTAX NwIpxBcastIfCtrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is the primary index into the Broadcast Interface Counter Table. This number corresponds to the index into the MIB 2 Interface Table which describes the router port for which the entry exists." INDEX { nwIpxBcastIfCtrIfIndex } ::= { nwIpxBcastIfCtrTable 1 } NwIpxBcastIfCtrEntry ::= SEQUENCE { nwIpxBcastIfCtrIfIndex INTEGER, nwIpxBcastIfCtrAdminStatus INTEGER, nwIpxBcastIfCtrReset INTEGER, nwIpxBcastIfCtrOperationalTime TimeTicks, nwIpxBcastIfCtrInPkts Counter, nwIpxBcastIfCtrOutPkts Counter, nwIpxBcastIfCtrFilteredPkts Counter, nwIpxBcastIfCtrDiscardPkts Counter, nwIpxBcastIfCtrInBytes Counter, nwIpxBcastIfCtrOutBytes Counter, nwIpxBcastIfCtrFilteredBytes Counter, nwIpxBcastIfCtrDiscardBytes Counter } nwIpxBcastIfCtrIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the primary index into the IPX Broadcast Interface Counter Table. This number corresponds to the index into the MIB 2 Interface Table which describes the router port for which the entry exists." ::= { nwIpxBcastIfCtrEntry 1 } nwIpxBcastIfCtrAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the IPX Broadcast packet and byte counters on the router port for which the entry exists. Enabled (3) causes these counters to become acive on the configured IPX Broadcast router port. Disabled (2) causes these counters to become inactive on the configured IPX Broadcast router port." ::= { nwIpxBcastIfCtrEntry 2 } nwIpxBcastIfCtrReset OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the IPX Broadcast packet and byte counters on the router port for which the entry exists. Reset (2) resets the interface-specific counters to 0. nwIpxBcastIfCtrOperationalTime is also reset to 0." ::= { nwIpxBcastIfCtrEntry 3 } nwIpxBcastIfCtrOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the amount of time, in hundredths of a second, that the interface-specific IPX Broadcast packet and byte counters have been in the current administrative state on the router port for which the entry exists." ::= { nwIpxBcastIfCtrEntry 4 } nwIpxBcastIfCtrInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX Broadcast packets that have been recieved, on the router port for which the entry exists, during nwIpxBcastIfCtrOperationalTime." ::= { nwIpxBcastIfCtrEntry 5 } nwIpxBcastIfCtrOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of Broadcast packets that have been transmitted, on the router port for which the entry existsl, during nwIpxBcastIfCtrOperationalTime." ::= { nwIpxBcastIfCtrEntry 6 } nwIpxBcastIfCtrFilteredPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX Broadcast packets that have been administratively filtered, on the router port for which the entry exists, during nwIpxBcastIfCtrOperationalTime." ::= { nwIpxBcastIfCtrEntry 7 } nwIpxBcastIfCtrDiscardPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of Broadcast packets that have been dis- carded, on the router port for which the entry exists, during nwIpxBcastIfCtrOperationalTime." ::= { nwIpxBcastIfCtrEntry 8 } nwIpxBcastIfCtrInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX Broadcast packets that have been recieved, on the router port for which the entry exists, during nwIpxBcastIfCtrOperationalTime." ::= { nwIpxBcastIfCtrEntry 9 } nwIpxBcastIfCtrOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX Broadcast packets that have been transmitted, on the router port for which the entry exists, during nwIpxBcastIfCtrOperationalTime." ::= { nwIpxBcastIfCtrEntry 10 } nwIpxBcastIfCtrFilteredBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX Broadcast packets that have been administratively filtered on the router port for which the entry exists during nwIpxBcastIfCtrOperationalTime." ::= { nwIpxBcastIfCtrEntry 11 } nwIpxBcastIfCtrDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX Broadcast packets that have been discarded on the router port for which the entry exists, during nwIpxBcastIfCtrOperationalTime." ::= { nwIpxBcastIfCtrEntry 12 } -- IPX Echo System Group -- Echo messages provide the ability to check for host reachability and -- network connectivity. If the router receives an ECHO message, it -- sends and ECHO reply to the source of the ECHO message. nwIpxEchoAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- shutdown the router enabled(3) -- startup the router } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the IPX Echo. Enabled (3) causes IPX ECHO to become active on any configured IPX router ports. Disabled (2) causes IPX Echo to perform a graceful shutdown on any active IPX router port." DEFVAL { disabled } ::= { nwIpxEchoConfig 1 } nwIpxEchoOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- not running enabled(3), -- running pending-disable(4), -- shut-down in progress pending-enable(5), -- start-up in progress invalid-config(6) -- not running,invalid config } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the operating condition of IPX Echo." ::= { nwIpxEchoConfig 2 } nwIpxEchoAdminReset OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following reset(2) -- force a reset } ACCESS read-write STATUS mandatory DESCRIPTION "Resets IPX Echo. Reset (2) will force a restart of IPX Echo without a graceful shutdown on any active IPX router port, without effecting any other router applications." ::= { nwIpxEchoConfig 3 } nwIpxEchoOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the amount of time, in hundredths of a second, that IPX Echo has been in its current administrative state, nwIpxEchoOperStatus." ::= { nwIpxEchoConfig 4 } nwIpxEchoVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current revision level of IPX Echo firmware." ::= { nwIpxEchoConfig 5 } -- IPX Echo System (aggregate) Counters -- This group contains the aggregate (device-wide) IPX Echo packet -- and byte counters. nwIpxEchoCtrAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the aggregae (device-wide) IPX Echo packet and byte counters. Enabled (3) causes these counters to become active on any router port running IPX Echo. Disabled (2) causes these counters to become inactive on all router ports." ::= { nwIpxEchoCounters 1 } nwIpxEchoCtrReset OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the aggregate (device-wide) IPX Echo packet and byte counters. Reset (2) resets the IPX Echo aggregate counters to 0. nwIpxEchoCtrOperationalTime is also reset to 0." ::= { nwIpxEchoCounters 2 } nwIpxEchoCtrOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the amount of time, in hundredths of a second, that the aggreagate (device-wide) IPX Echo packet and byte counters have been in the current administrative state." ::= { nwIpxEchoCounters 3 } nwIpxEchoCtrInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX Echo packets that have been recieved, device-wide, during nwIpxEchoCtrOperationalTime." ::= { nwIpxEchoCounters 4 } nwIpxEchoCtrOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX Echo packets that have been transmitted, device-wide, during nwIpxEchoCtrOperationalTIme." ::= { nwIpxEchoCounters 5 } nwIpxEchoCtrFilteredPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX Echo packets that have been administratively filtered, device-wide, during nwIpxEchoCtrOperationalTime." ::= { nwIpxEchoCounters 6 } nwIpxEchoCtrDiscardPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX Echo packets that have been discarded, device-wide, during nwIpxEchoCtrOperationalTime." ::= { nwIpxEchoCounters 7 } nwIpxEchoCtrInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX Echo packets that have been recieved, device-wide, during nwIpxEchoCtrOperationalTime." ::= { nwIpxEchoCounters 8 } nwIpxEchoCtrOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX Echo packets that have been transmitted, device-wide, during nwIpxEchoCtrOperationalTime." ::= { nwIpxEchoCounters 9 } nwIpxEchoCtrFilteredBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX Echo packets that have been administratively filtered, device-wide, during nwIpxEchoCtrOperationalTime." ::= { nwIpxEchoCounters 10 } nwIpxEchoSCtrDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the Echo packets that have been discarded, during nwIpxEchoCtrOperationalTime." ::= { nwIpxEchoCounters 11 } -- IPX Echo Interface Table -- This table contains the managed objects used to setup and configure -- Echo on a per router port basis. nwIpxEchoIfTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxEchoIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry for each router port configured for IPX Echo. Each entry can contain different values, allowing the routing protocol configuration to vary from router port to router port. This table is indexed by nwIpxEchoIfIndex, which indicates the value of MIB 2 ifindex, which identifies the router port for which the entry exists." ::= { nwIpxEchoIfConfig 1 } nwIpxEchoIfEntry OBJECT-TYPE SYNTAX NwIpxEchoIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Specifies the IPX Echo information for the logical IPX interface for which the entry exists." INDEX { nwIpxEchoIfIndex } ::= { nwIpxEchoIfTable 1 } NwIpxEchoIfEntry ::= SEQUENCE { nwIpxEchoIfIndex INTEGER, nwIpxEchoIfAdminStatus INTEGER, nwIpxEchoIfOperStatus INTEGER, nwIpxEchoIfOperationalTime TimeTicks } nwIpxEchoIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This index corresponds to the primary index into the MIB 2 ifTable, which describes the router port for which the entry exists." ::= { nwIpxEchoIfEntry 1 } nwIpxEchoIfAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of IPX Echo on the router port for which the entry exists. Enabled (2) causes this router port to become active. Disabled (3) causes this router port to become inactive." DEFVAL { enabled } ::= { nwIpxEchoIfEntry 2 } nwIpxEchoIfOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- not running enabled(3), -- running pending-disable(4), -- shut-down in progress pending-enable(5), -- start-up in progress invalid-config(6) -- not running,invalid config } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current operating condition of IPX Echo on the router port for which the entry exists." ::= { nwIpxEchoIfEntry 3 } nwIpxEchoIfOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that nwIpxEchoIfAdminStatus has been in its current state." ::= { nwIpxEchoIfEntry 4 } -- IPX Echo Interface Counters Table -- This table contains the managed objects for IPX Echo packet and -- byte counter on a per router port basis. nwIpxEchoIfCtrTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxEchoIfCtrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the IPX Echo packet and byte counters for each router port on this device." ::= { nwIpxEchoIfCounters 1 } nwIpxEchoIfCtrEntry OBJECT-TYPE SYNTAX NwIpxEchoIfCtrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is the primary index into the Echo Interface Counter Table. This number corresponds to the index into the MIB 2 Interface Table which describes the router port for which the entry exists." INDEX { nwIpxEchoIfCtrIfIndex } ::= { nwIpxEchoIfCtrTable 1 } NwIpxEchoIfCtrEntry ::= SEQUENCE { nwIpxEchoIfCtrIfIndex INTEGER, nwIpxEchoIfCtrAdminStatus INTEGER, nwIpxEchoIfCtrReset INTEGER, nwIpxEchoIfCtrOperationalTime TimeTicks, nwIpxEchoIfCtrInPkts Counter, nwIpxEchoIfCtrOutPkts Counter, nwIpxEchoIfCtrFilteredPkts Counter, nwIpxEchoIfCtrDiscardPkts Counter, nwIpxEchoIfCtrInBytes Counter, nwIpxEchoIfCtrOutBytes Counter, nwIpxEchoIfCtrFilteredBytes Counter, nwIpxEchoIfCtrDiscardBytes Counter } nwIpxEchoIfCtrIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the primary index into the IPX Echo Interface Counter Table. This number corresponds to the index into the MIB 2 Interfcace Table which describes the router port for which the entry exists." ::= { nwIpxEchoIfCtrEntry 1 } nwIpxEchoIfCtrAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the IPX Echo packet and byte counters on the IPX router port for which the entry exists. Enabled (3) causes these counters to become active on the router port configured for IPX Echo. Disabled (2) causes these counters to become inactive on the configured IPX Echo router port." ::= { nwIpxEchoIfCtrEntry 2 } nwIpxEchoIfCtrReset OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the IPX Echo packet andbyte counters on the router port for which the entryexists. Reset (2) resets the interface-specific counters to 0. nwIpxEchoIfCtrOperationalTime is also reset to 0." ::= { nwIpxEchoIfCtrEntry 3 } nwIpxEchoIfCtrOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the amount of time, in hundredths of a second, that the interface-specific IPX Echo packet and byte counters have been in the current administrative state on the router port for which the entry exists." ::= { nwIpxEchoIfCtrEntry 4 } nwIpxEchoIfCtrInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX Echo packets that have been recieved, on the router port for which the entry exists, during nwIpxEchoIfCtrOperationalTime." ::= { nwIpxEchoIfCtrEntry 5 } nwIpxEchoIfCtrOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX Echo packets that have been transmitted, on the router port for which the entry exists, during nwIpxEchoIfCrOperationalTIme." ::= { nwIpxEchoIfCtrEntry 6 } nwIpxEchoIfCtrFilteredPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX Echo packets that have been administratively filtered, on the router port for which the entry exists, during nwIpxEchoIfCtrOperationalTime." ::= { nwIpxEchoIfCtrEntry 7 } nwIpxEchoIfCtrDiscardPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of IPX Echo packets that have been discaded, on the router port for which the entry exists, during nwIpxEchoIfCtrOperationalTime." ::= { nwIpxEchoIfCtrEntry 8 } nwIpxEchoIfCtrInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX Echo packets that have been recieved, on the router port for which the entry exists, during nwIpxEchoIfCtrOpeationalTime." ::= { nwIpxEchoIfCtrEntry 9 } nwIpxEchoIfCtrOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX Echo packets that have been transmitted, on the router port for which the entry exists, during nwIpxEchoIfCtrOperationalTime." ::= { nwIpxEchoIfCtrEntry 10 } nwIpxEchoIfCtrFilteredBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX Echo packets that have been administratively filtered and recieved on the router port for which the entry exists, during nwIpxEchoIfCtrOperationalTime." ::= { nwIpxEchoIfCtrEntry 11 } nwIpxEchoIfCtrDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the IPX Echo packets that have been discarded, that were recieved on the router port for which the entry exists, during nwIpxEchoIfCtrOperationalTime." ::= { nwIpxEchoIfCtrEntry 12 } -- -- IPX Hosts-to-Media Table -- This table provides a mapping between IPX Network Protocol -- addresses and their corresponding circuit identifiers (if -- applicable), port numbers, and framing. nwIpxHostMapTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxHostMapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Ipx Address translation table used for mapping an IPX address to a circuit identifier (if applicable), corresponding port number, and framing type." ::= { nwIpxHostsToMedia 1 } nwIpxHostMapEntry OBJECT-TYPE SYNTAX NwIpxHostMapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains one IpxAddress to circuit equivalence. Also provided is the framing required to converse with this host, and the corresponding logical port number." INDEX { nwIpxHostMapIfIndex, nwIpxHostMapIpxAddr } ::= { nwIpxHostMapTable 1 } NwIpxHostMapEntry ::= SEQUENCE { nwIpxHostMapIfIndex INTEGER, nwIpxHostMapIpxAddr IpxAddress, nwIpxHostMapPhysAddr PhysAddress, nwIpxHostMapType INTEGER, nwIpxHostMapCircuitID INTEGER, nwIpxHostMapFraming INTEGER, nwIpxHostMapPortNumber INTEGER } nwIpxHostMapIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the primary (major) index into the Ipx HostMap table. This number corresponds to the index into the MIB-2 Interfaces Group which describes the IPX router port for which the entry exists." ::= { nwIpxHostMapEntry 1 } nwIpxHostMapIpxAddr OBJECT-TYPE SYNTAX IpxAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IpxAddress of the host on the corresponding interface and circuit (if applicable). The IpxAddress consists of a network number of 4 octets followed by 6 octets of node identifier." ::= { nwIpxHostMapEntry 2 } nwIpxHostMapPhysAddr OBJECT-TYPE SYNTAX PhysAddress ACCESS read-write STATUS mandatory DESCRIPTION "The media-dependent 'physical' address. The value of this object is 0 for entries indicating native-wan(8) framing." ::= { nwIpxHostMapEntry 3 } nwIpxHostMapType OBJECT-TYPE SYNTAX INTEGER { other(1), invalid(2), dynamic(3), static(4), inactive(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object to the value invalid(2) has the effect of invalidating the corresponding entry in the nwIpxHostMapTable. That is, it effectively dissasociates the circuit and/or interface identified with said entry from the mapping identified with said entry. It is an implementation- specific matter as to whether the agent removes an invalidated entry from the table. Accordingly, management stations must be prepared to receive tabular information from agents that corresponds to entries not currently in use. Proper inter- pretation of such entries requires examination of the relevant wIpxHostMapType object." ::= { nwIpxHostMapEntry 4 } nwIpxHostMapCircuitID OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The identifier for the virtual circuit present on the interface. On an interface configured for Frame Relay, this number is the DLCI for the IPX Address at the end of the circuit. For non-WAN interfaces, the value of this object is zero." ::= { nwIpxHostMapEntry 5 } nwIpxHostMapFraming OBJECT-TYPE SYNTAX INTEGER { -- valid media types other(1), -- experimental ethernet(2), -- ethernet snap(3), -- enet,fddi,and token ring i8022(4), -- enet, token ring, and fddi novell(6), -- ethernet and fddi nativewan(8), -- wan media types encapenet(9), -- wan media types encapenet8022(10), -- wan media types encapenetsnap(11), -- wan media types encapenetnovell(12), -- wan media types encaptr8022(13), -- wan media types encaptrsnap(14), -- wan media types encapfddi8022(15), -- wan media types encapfddisnap(16), -- wan media types canonical(17) -- special, tbd } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the framing type required to converse with the host for which this entry exists." ::= { nwIpxHostMapEntry 6 } nwIpxHostMapPortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unique value for the logical port number. It's value ranges between 1 and a maximum value which is dependent on both the number of configured interfaces in the system and the number of circuits present on those interfaces which are of WAN type." ::= { nwIpxHostMapEntry 7 } -- IPX Event Group nwIpxEventAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of IPX event logging. Enabled (3) causes the event log to become active. Disabled (2) causes the event log to become inactive." DEFVAL { disabled } ::= { nwIpxEventLogConfig 1 } nwIpxEventMaxEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Sets the maximum size of the event log table. When the table size exceeds the maximum, the first entry is deleted until the size of the table does not exceed the maximum." DEFVAL { 100 } ::= { nwIpxEventLogConfig 2 } nwIpxEventTraceAll OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the event log. Enabled (3) allows logging of all event types on all router ports from all protocols and components. Disabled (2) causes the filter table to specify which events to log." DEFVAL { enabled } ::= { nwIpxEventLogConfig 3 } -- Event Log Filter Table -- The Event Log Filter Table contains the managed objects used to set-up -- and configure log entries. nwIpxEventFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxEventFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry for each event filter configured for IPX Routing Services events." ::= { nwIpxEventLogFilterTable 1 } nwIpxEventFilterEntry OBJECT-TYPE SYNTAX NwIpxEventFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry describes an event filter which defines a particular type of event to be logged to the event log. The nwIpxEventProtocol refers to the instance used in the nwRtgProtocolTable and nwComponentTable specified by the Cabletron Routing Services MIB, and identifies the protocol to which the entry applies." INDEX { nwIpxEventFltrProtocol, nwIpxEventFltrIfNum } ::= { nwIpxEventFilterTable 1 } NwIpxEventFilterEntry ::= SEQUENCE { nwIpxEventFltrProtocol INTEGER, nwIpxEventFltrIfNum INTEGER, nwIpxEventFltrControl INTEGER, nwIpxEventFltrType INTEGER, nwIpxEventFltrSeverity INTEGER, nwIpxEventFltrAction INTEGER } nwIpxEventFltrProtocol OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the routing protocol involved in the event for which the event filter exists." ::= { nwIpxEventFilterEntry 1 } nwIpxEventFltrIfNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the router port involved in the event for which the event filter exists." ::= { nwIpxEventFilterEntry 2 } nwIpxEventFltrControl OBJECT-TYPE SYNTAX INTEGER { other(1), delete(2), add(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Set this value to 3 to add the event filter to the Event Filter Table. Set this value to 2 to delete the event filter from the Event Filter Table." DEFVAL { add } ::= { nwIpxEventFilterEntry 3 } nwIpxEventFltrType OBJECT-TYPE SYNTAX INTEGER { misc(1), timer(2), rcv(4), xmit(8), event(16), error(32) } ACCESS read-write STATUS mandatory DESCRIPTION "This 6 bit mask specifies the types of events to be logged. By default all 6 bits are set to 1, indicating that all types of events will be logged. Setting any bit to 0 removes an event type from this field and prevents that type of event from being logged. Adding event types to this field will enable those types of events to be logged." DEFVAL { misc } ::= { nwIpxEventFilterEntry 4 } nwIpxEventFltrSeverity OBJECT-TYPE SYNTAX INTEGER { highest(1), highmed(2), highlow(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object controls the amount of logging by ignoring events of lower priority than specified by this filter value. The highest value will ignore all events except those of the highest severity. `Highmed' will log all events highest priority through lowest. `Highlow' will log all events highest priority through lowest. The `highmed' severity is the default setting." DEFVAL { highest } ::= { nwIpxEventFilterEntry 5 } nwIpxEventFltrAction OBJECT-TYPE SYNTAX INTEGER { log(1), trap(2), log-trap(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This field specifies how the events are to be logged. Logging to the `log' stores the events in the event log table. Logging to `trap' sends events out through the trap mechanism." DEFVAL { log } ::= { nwIpxEventFilterEntry 6 } -- Event Log Table -- The Event Log Table contains the logged events. nwIpxEventTable OBJECT-TYPE SYNTAX SEQUENCE OF NwIpxEventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry for each event that has been logged." ::= { nwIpxEventLogTable 1 } nwIpxEventEntry OBJECT-TYPE SYNTAX NwIpxEventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the information about an event that has been logged to the event table." INDEX { nwIpxEventNumber } ::= { nwIpxEventTable 1 } NwIpxEventEntry ::= SEQUENCE { nwIpxEventNumber INTEGER, nwIpxEventTime TimeTicks, nwIpxEventType INTEGER, nwIpxEventSeverity INTEGER, nwIpxEventProtocol INTEGER, nwIpxEventIfNum INTEGER, nwIpxEventTextString OCTET STRING } nwIpxEventNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An ordinal value assigned to the event for which the entry exists. nwIpxEventNumber is assigned so that each event in the event log can be uniquely identified by the value of nwIpxEventNumber." ::= { nwIpxEventEntry 1 } nwIpxEventTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the time at which the event was logged to the event log." ::= { nwIpxEventEntry 2 } nwIpxEventType OBJECT-TYPE SYNTAX INTEGER { misc(1), timer(2), rcv(4), xmit(8), event(16), error(32) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the type of event that was logged." ::= { nwIpxEventEntry 3 } nwIpxEventSeverity OBJECT-TYPE SYNTAX INTEGER { highest(1), highmed(2), highlow(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the priority that was assigned to this type event." ::= { nwIpxEventEntry 4 } nwIpxEventProtocol OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the routing protocol that was involved in this event." ::= { nwIpxEventEntry 5 } nwIpxEventIfNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the router port that was involved in the event." ::= { nwIpxEventEntry 6 } nwIpxEventTextString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Contains the actual text string that was logged." ::= { nwIpxEventEntry 7 } END