-- ***************************************************************** -- RBN-ENVMON-MIB Environmental Monitor MIB -- -- Copyright (c) 1999-2007, 2010-2011 Ericsson AB -- All rights reserved. -- -- ***************************************************************** RBN-ENVMON-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Integer32 FROM SNMPv2-SMI DisplayString, TruthValue, TEXTUAL-CONVENTION FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF entPhysicalIndex FROM ENTITY-MIB rbnMgmt FROM RBN-SMI; rbnEnvMonMIB MODULE-IDENTITY LAST-UPDATED "201210030000Z" -- October 3, 2012 ORGANIZATION "Ericsson AB." CONTACT-INFO " Ericsson AB. Postal: 100 Headquarters Dr. San Jose, CA 95134 USA Phone: +1 408 750 5000 Fax: +1 408 750 5599 " DESCRIPTION "The MIB used to genericially manage Environmental Monitor functionality on network devices." REVISION "201210030000Z" -- October 3, 2012 DESCRIPTION "Removed DISPLAY-HINT from RbnVoltage and RbnFanSpeed." REVISION "201101191800Z" -- Jan 19, 2011 DESCRIPTION "Update CONTACT-INFO & ORGANIZATION. " REVISION "201011110000Z" -- Nov 11, 2010 DESCRIPTION "Add new Table rbnEntityTempSensorTable. This will display the TempSensor Details for all the entities. " REVISION "200601160000Z" -- January 16, 2006 DESCRIPTION "Add textual convention RbnFanSpeed. Add new OIDs: rbnFanUnitID rbnFanUnitDescr rbnFanSpeedCurrent rbnEnvMonFanSpeedObjectGroup rbnEnvMonMIBComplianceV4 " REVISION "200206050000Z" -- June 5, 2002 DESCRIPTION "Update/correct CONTACT-INFO. Fix syntax errors on IMPORTS list, ranges on Integer32, and size for DisplayString types. Restore the incorrectly deprecated OIDs to current, since they are still supported." REVISION "200107250000Z" -- July 25, 2001 DESCRIPTION "Added new OIDs: rbnFanStatus rbnPowerStatus rbnFanStatusChange rbnPowerStatusChange rbnEnvMonMIBObjectGroupV2 rbnEnvMonMIBNotificationGroupV2 rbnEnvMonMIBComplianceV3 Deprecated the OIDs: rbnFanFail rbnPowerFail rbnFanFailChange rbnPowerFailChange rbnEnvMonMIBObjectGroup rbnEnvMonMIBNotificationGroup rbnEnvMonMIBComplianceV2 " REVISION "200004240000Z" -- May 24, 2000 DESCRIPTION "Added voltage and temperature sensor tables." REVISION "199903100000Z" -- Mar 10, 1999 DESCRIPTION "Initial version." ::= { rbnMgmt 4 } rbnEnvMonMIBNotifications OBJECT IDENTIFIER ::= { rbnEnvMonMIB 0 } rbnEnvMonMIBObjects OBJECT IDENTIFIER ::= { rbnEnvMonMIB 1 } rbnEnvMonMIBConformance OBJECT IDENTIFIER ::= { rbnEnvMonMIB 2 } -- Textual Conventions RbnVoltage ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents a voltage value. The value is millivolts. For example, a voltage of 5.5V would be represented by the value 5500." SYNTAX Unsigned32 (0..50000) RbnTemperature ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "Represents a temperature, in degrees Celsius. In the unlikely event that the temperature to be reported is less than 0 degrees Celsius, a value of 0 will be used. Likewise, if the temperature is greater than 100, a value of 100 will be used." SYNTAX Unsigned32 (0..100) RbnFanSpeed ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents a fan speed value in units of Revolutions Per Minute(RPM)." SYNTAX Unsigned32 -- MIB Objects rbnFanStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF RbnFanStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per fan test point. Note that there is not necessarily a one-to-one relationship between fan test points and fan assemblies; a single test point may be used to monitor the status of multiple fans." ::= { rbnEnvMonMIBObjects 1 } rbnFanStatusEntry OBJECT-TYPE SYNTAX RbnFanStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular fan test point" INDEX { rbnFanIndex } ::= { rbnFanStatusTable 1 } RbnFanStatusEntry ::= SEQUENCE { rbnFanIndex Integer32, rbnFanDescr DisplayString, rbnFanFail TruthValue, rbnFanStatus INTEGER } rbnFanIndex OBJECT-TYPE SYNTAX Integer32(1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of a fan test point." ::= { rbnFanStatusEntry 1 } rbnFanDescr OBJECT-TYPE SYNTAX DisplayString(SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The description of a fan test point. If an instance of this object is associated with a single fan assembly, then the value of this object should be the same as the name by which the assembly is normally referenced. If an instance is associated with multiple fan assemblies, then the value of this object should contain the names of all of the fan assemblies being monitored." ::= { rbnFanStatusEntry 2 } rbnFanFail OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The status of a fan test point. If an instance of this object has the value true, then a fan monitored by the test point has failed. If an instance of this object has the value false, then the fan (or fans) monitored by the test point are operational." ::= { rbnFanStatusEntry 3 } rbnFanStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), failed(2), absent(3), unknown(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of a fan test point. If an instance of this object has the value normal, then the fan (or fans) monitored by the test point is operational. If an instance of this object has the value failed, then the fan (or fans) monitored by the test point has failed. If an instance of this object has the value absent, then the fan (or fans) monitored by this test point is not present. If an instance of this object has the value unknown, then the test point is unable to monitor the fan (or fans)." ::= { rbnFanStatusEntry 4 } rbnPowerStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF RbnPowerStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per power test point. Note that there is not necessarily a one-to-one relationship between power test points and power supply assemblies; a single test point may be used to monitor the status of multiple power supplies." ::= { rbnEnvMonMIBObjects 2 } rbnPowerStatusEntry OBJECT-TYPE SYNTAX RbnPowerStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular power test point" INDEX { rbnPowerIndex } ::= { rbnPowerStatusTable 1 } RbnPowerStatusEntry ::= SEQUENCE { rbnPowerIndex Integer32, rbnPowerDescr DisplayString, rbnPowerFail TruthValue, rbnPowerStatus INTEGER } rbnPowerIndex OBJECT-TYPE SYNTAX Integer32(1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of a power test point." ::= { rbnPowerStatusEntry 1 } rbnPowerDescr OBJECT-TYPE SYNTAX DisplayString(SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The description of a power supply test point. If an instance of this object is associated with a single power supply assembly, then the value of this object should be the same as the name by which the assembly is normally referenced. If an instance is associated with multiple power supply assemblies, then the value of this object should contain the names of all of the power supply assemblies being monitored." ::= { rbnPowerStatusEntry 2 } rbnPowerFail OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The status of a power test point. If an instance of this object has the value true, then a power supply monitored by the test point has failed. If an instance of this object has the value false, then the power supply (or supplies) monitored by the test point are operational." ::= { rbnPowerStatusEntry 3 } rbnPowerStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), failed(2), absent(3), unknown(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of a power test point. If an instance of this object has the value normal, then the power supply (or supplies) monitored by the test point is operational. If an instance of this object has the value failed, then the power supply (or supplies) monitored by the test point has failed. If an instance of this object has the value absent, then the power supply (or supplies) monitored by this test point is not present. If an instance of this object has the value unknown, then the test point is unable to monitor the power supply (or supplies)." ::= { rbnPowerStatusEntry 4 } rbnVoltageSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF RbnVoltageSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per voltage test point. Each physical entity (e.g. cards) in the system may contain zero or more voltage test points." ::= { rbnEnvMonMIBObjects 3 } rbnVoltageSensorEntry OBJECT-TYPE SYNTAX RbnVoltageSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular voltage test point." INDEX { entPhysicalIndex, rbnVoltageIndex } ::= { rbnVoltageSensorTable 1 } RbnVoltageSensorEntry ::= SEQUENCE { rbnVoltageIndex Integer32, rbnVoltageDescr DisplayString, rbnVoltageDesired RbnVoltage, rbnVoltageCurrent RbnVoltage } rbnVoltageIndex OBJECT-TYPE SYNTAX Integer32(1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary value which uniquely identifies a voltage test point on a particular physical entity. Index values for different test points are not necessarily contiguous." ::= { rbnVoltageSensorEntry 1 } rbnVoltageDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..48)) MAX-ACCESS read-only STATUS current DESCRIPTION "The description of a voltage test point. Typically an instance of this object will hold a user-friendly description of the physical entity and the level of voltage being monitored by this test point." ::= { rbnVoltageSensorEntry 2 } rbnVoltageDesired OBJECT-TYPE SYNTAX RbnVoltage UNITS "millivolts" MAX-ACCESS read-only STATUS current DESCRIPTION "The desired voltage level for this test point. If the monitored voltage level (rbnVoltageCurrent) is equal to this value, then the system is performing as designed." ::= { rbnVoltageSensorEntry 3 } rbnVoltageCurrent OBJECT-TYPE SYNTAX RbnVoltage UNITS "millivolts" MAX-ACCESS read-only STATUS current DESCRIPTION "The current voltage level at this test point." ::= { rbnVoltageSensorEntry 4 } rbnCpuTempSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF RbnCpuTempSensorEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This table contains one row per CPU temperature sensor. Each physical entity in the system may have zero or more CPUs. Each of those CPUs that has a temperature sensor will show up here." ::= { rbnEnvMonMIBObjects 4 } rbnCpuTempSensorEntry OBJECT-TYPE SYNTAX RbnCpuTempSensorEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Information about a particular CPU temperature test point." INDEX { entPhysicalIndex, rbnCpuTempIndex } ::= { rbnCpuTempSensorTable 1 } RbnCpuTempSensorEntry ::= SEQUENCE { rbnCpuTempIndex Integer32, rbnCpuTempDescr DisplayString, rbnCpuTempCurrent RbnTemperature } rbnCpuTempIndex OBJECT-TYPE SYNTAX Integer32(1..2147483647) MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "An arbitrary value which uniquely identifies a CPU on a particular physical entity. Index values for different CPUs are not necessarily contiguous." ::= { rbnCpuTempSensorEntry 1 } rbnCpuTempDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..48)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The description of a CPU temperature test point. Typically an instance of this object will hold a user-friendly description of the physical entity and a description of the CPU being monitored by this test point." ::= { rbnCpuTempSensorEntry 2 } rbnCpuTempCurrent OBJECT-TYPE SYNTAX RbnTemperature UNITS "degrees" MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The current temperature of this CPU." ::= { rbnCpuTempSensorEntry 3 } rbnFanSpeedTable OBJECT-TYPE SYNTAX SEQUENCE OF RbnFanSpeedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per fan unit within a fan test point." ::= { rbnEnvMonMIBObjects 5 } rbnFanSpeedEntry OBJECT-TYPE SYNTAX RbnFanSpeedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular fan unit within a fan test point." INDEX { rbnFanIndex, rbnFanUnitID } ::= { rbnFanSpeedTable 1 } RbnFanSpeedEntry ::= SEQUENCE { rbnFanUnitID Integer32, rbnFanUnitDescr DisplayString, rbnFanSpeedCurrent RbnFanSpeed } rbnFanUnitID OBJECT-TYPE SYNTAX Integer32(1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the fan identification number that describes the specific location of the fan unit within a fan test point." ::= { rbnFanSpeedEntry 1 } rbnFanUnitDescr OBJECT-TYPE SYNTAX DisplayString(SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The description of the fan unit within a fan test point." ::= { rbnFanSpeedEntry 2 } rbnFanSpeedCurrent OBJECT-TYPE SYNTAX RbnFanSpeed MAX-ACCESS read-only STATUS current DESCRIPTION "The current speed of this fan unit." ::= { rbnFanSpeedEntry 3 } rbnEntityTempSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF RbnEntityTempSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per temperature sensor on the physical entity." ::= { rbnEnvMonMIBObjects 6 } rbnEntityTempSensorEntry OBJECT-TYPE SYNTAX RbnEntityTempSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular temperature test point." INDEX { entPhysicalIndex, rbnEntityTempIndex } ::= { rbnEntityTempSensorTable 1 } RbnEntityTempSensorEntry ::= SEQUENCE { rbnEntityTempIndex Integer32, rbnEntityTempDescr DisplayString, rbnEntityTempCurrent RbnTemperature } rbnEntityTempIndex OBJECT-TYPE SYNTAX Integer32(1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary value which uniquely identifies a particular physical entity. Index values are not necessarily contiguous." ::= { rbnEntityTempSensorEntry 1 } rbnEntityTempDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..48)) MAX-ACCESS read-only STATUS current DESCRIPTION "The description of a temperature test point. Typically an instance of this object will hold a user-friendly description of the physical entity being monitored by this test point." ::= { rbnEntityTempSensorEntry 2 } rbnEntityTempCurrent OBJECT-TYPE SYNTAX RbnTemperature UNITS "degrees Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "The current temperature of this entity in degrees Celsius." ::= { rbnEntityTempSensorEntry 3 } -- Notifications rbnFanFailChange NOTIFICATION-TYPE OBJECTS { rbnFanFail } STATUS deprecated DESCRIPTION "A rbnFanFailChange notification signifies that the value of an instance of rbnFanFail has changed." ::= { rbnEnvMonMIBNotifications 1 } rbnPowerFailChange NOTIFICATION-TYPE OBJECTS { rbnPowerFail } STATUS deprecated DESCRIPTION "A rbnPowerFailChange notification signifies that the value of an instance of rbnPowerFail has changed" ::= { rbnEnvMonMIBNotifications 2 } rbnFanStatusChange NOTIFICATION-TYPE OBJECTS { rbnFanStatus } STATUS current DESCRIPTION "A rbnFanStatusChange notification signifies that the value of an instance of rbnFanStatus has changed." ::= { rbnEnvMonMIBNotifications 3 } rbnPowerStatusChange NOTIFICATION-TYPE OBJECTS { rbnPowerStatus } STATUS current DESCRIPTION "A rbnPowerStatusChange notification signifies that the value of an instance of rbnPowerStatus has changed" ::= { rbnEnvMonMIBNotifications 4 } -- Conformance Statements rbnEnvMonMIBGroups OBJECT IDENTIFIER ::= { rbnEnvMonMIBConformance 1 } rbnEnvMonMIBCompliances OBJECT IDENTIFIER ::= { rbnEnvMonMIBConformance 2 } rbnEnvMonMIBObjectGroup OBJECT-GROUP OBJECTS { rbnFanDescr, rbnFanFail, rbnPowerDescr, rbnPowerFail } STATUS deprecated DESCRIPTION "A collection of objects providing environmental monitor information." ::= { rbnEnvMonMIBGroups 1 } rbnEnvMonMIBNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { rbnFanFailChange, rbnPowerFailChange } STATUS deprecated DESCRIPTION "A collection of notifications providing fan and power environmental monitor information." ::= { rbnEnvMonMIBGroups 2 } rbnEnvMonVoltageObjectGroup OBJECT-GROUP OBJECTS { rbnVoltageDescr, rbnVoltageDesired, rbnVoltageCurrent } STATUS current DESCRIPTION "A collection of objects providing voltage environmental monitor information." ::= { rbnEnvMonMIBGroups 3 } rbnEnvMonTempObjectGroup OBJECT-GROUP OBJECTS { rbnCpuTempDescr, rbnCpuTempCurrent } STATUS deprecated DESCRIPTION "A collection of objects providing temperature environmental monitor information." ::= { rbnEnvMonMIBGroups 4 } rbnEnvMonMIBObjectGroupV2 OBJECT-GROUP OBJECTS { rbnFanDescr, rbnFanStatus, rbnPowerDescr, rbnPowerStatus } STATUS current DESCRIPTION "A collection of objects providing environmental monitor information." ::= { rbnEnvMonMIBGroups 5 } rbnEnvMonMIBNotificationGroupV2 NOTIFICATION-GROUP NOTIFICATIONS { rbnFanStatusChange, rbnPowerStatusChange } STATUS current DESCRIPTION "A collection of notifications providing fan and power environmental monitor information." ::= { rbnEnvMonMIBGroups 6 } rbnEnvMonFanSpeedObjectGroup OBJECT-GROUP OBJECTS { rbnFanUnitDescr, rbnFanSpeedCurrent } STATUS current DESCRIPTION "A collection of objects providing fan speed environmental monitor information." ::= { rbnEnvMonMIBGroups 7 } rbnEnvMonEntityObjectGroup OBJECT-GROUP OBJECTS { rbnEntityTempDescr, rbnEntityTempCurrent } STATUS current DESCRIPTION "A collection of objects providing fan speed environmental monitor information." ::= { rbnEnvMonMIBGroups 8 } rbnEnvMonMIBCompliance MODULE-COMPLIANCE STATUS obsolete DESCRIPTION "The compliance statement for the EnvMon MIB" MODULE -- this module GROUP rbnEnvMonMIBObjectGroup DESCRIPTION "This group is mandatory for devices which contain Environmental Monitoring capabilities" GROUP rbnEnvMonMIBNotificationGroup DESCRIPTION "This group is mandatory for devices which contain Environmental Monitoring capabilities" ::= { rbnEnvMonMIBCompliances 1 } rbnEnvMonMIBComplianceV2 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for the EnvMon MIB" MODULE -- this module GROUP rbnEnvMonMIBObjectGroup DESCRIPTION "This group is mandatory for devices which contain Environmental Monitoring capabilities" GROUP rbnEnvMonMIBNotificationGroup DESCRIPTION "This group is mandatory for devices which contain Environmental Monitoring capabilities" GROUP rbnEnvMonVoltageObjectGroup DESCRIPTION "This group is mandatory for devices which are capable of sensing system voltages." GROUP rbnEnvMonTempObjectGroup DESCRIPTION "This group is mandatory for devices which are capable of sensing system temperatures." ::= { rbnEnvMonMIBCompliances 2 } rbnEnvMonMIBComplianceV3 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for the EnvMon MIB" MODULE -- this module GROUP rbnEnvMonMIBObjectGroupV2 DESCRIPTION "This group is mandatory for devices which contain Environmental Monitoring capabilities" GROUP rbnEnvMonMIBNotificationGroupV2 DESCRIPTION "This group is mandatory for devices which contain Environmental Monitoring capabilities" GROUP rbnEnvMonVoltageObjectGroup DESCRIPTION "This group is mandatory for devices which are capable of sensing system voltages." GROUP rbnEnvMonTempObjectGroup DESCRIPTION "This group is mandatory for devices which are capable of sensing system temperatures." ::= { rbnEnvMonMIBCompliances 3 } rbnEnvMonMIBComplianceV4 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for the EnvMon MIB" MODULE -- this module GROUP rbnEnvMonMIBObjectGroupV2 DESCRIPTION "This group is mandatory for devices which contain Environmental Monitoring capabilities" GROUP rbnEnvMonMIBNotificationGroupV2 DESCRIPTION "This group is mandatory for devices which contain Environmental Monitoring capabilities" GROUP rbnEnvMonVoltageObjectGroup DESCRIPTION "This group is mandatory for devices which are capable of sensing system voltages." GROUP rbnEnvMonTempObjectGroup DESCRIPTION "This group is mandatory for devices which are capable of sensing system temperatures." GROUP rbnEnvMonFanSpeedObjectGroup DESCRIPTION "This group is mandatory for SNMP entities which are capable of sensing fan speeds." ::= { rbnEnvMonMIBCompliances 4 } rbnEnvMonMIBComplianceV5 MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for the EnvMon MIB" MODULE -- this module GROUP rbnEnvMonMIBObjectGroupV2 DESCRIPTION "This group is mandatory for devices which contain Environmental Monitoring capabilities" GROUP rbnEnvMonMIBNotificationGroupV2 DESCRIPTION "This group is mandatory for devices which contain Environmental Monitoring capabilities" GROUP rbnEnvMonVoltageObjectGroup DESCRIPTION "This group is mandatory for devices which are capable of sensing system voltages." GROUP rbnEnvMonFanSpeedObjectGroup DESCRIPTION "This group is mandatory for SNMP entities which are capable of sensing fan speeds." GROUP rbnEnvMonEntityObjectGroup DESCRIPTION "This group is mandatory for devices which contain Environmental Monitoring capabilities, also applicable to SSE card and disks" ::= { rbnEnvMonMIBCompliances 5 } END