FOUNDRY-SN-MRP-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32 FROM SNMPv2-SMI InterfaceIndex FROM IF-MIB DisplayString FROM SNMPv2-TC; snMetroRing MODULE-IDENTITY LAST-UPDATED "201006020000Z" -- 04 June 2010 ORGANIZATION "Brocade Communications Systems, Inc." CONTACT-INFO "Technical Support Center 130 Holger Way, San Jose, CA 95134 Email: ipsupport@brocade.com Phone: 1-800-752-8061 URL: www.brocade.com" DESCRIPTION "Management Information Base module for metro ring configuration and statistics. Copyright 1996-2010 Brocade Communications Systems, Inc. All rights reserved. This Brocade Communications Systems SNMP Management Information Base Specification embodies Brocade Communications Systems' confidential and proprietary intellectual property. Brocade Communications Systems retains all title and ownership in the Specification, including any revisions. This Specification is supplied AS IS, and Brocade Communications Systems makes no warranty, either express or implied, as to the use, operation, condition, or performance of the specification, and any unintended consequence it may on the user environment." REVISION "201006020000Z" -- 04 June 2010 DESCRIPTION "Changed the ORGANIZATION, CONTACT-INFO and DESCRIPTION fields." REVISION "200705160000Z" -- May 16, 2007 DESCRIPTION "" ::= { iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) foundry(1991) products(1) switch(1) snSwitch(3) 29 } snMetroRingGlobalObjects OBJECT IDENTIFIER ::= { snMetroRing 1 } snMetroRingTableObjects OBJECT IDENTIFIER ::= { snMetroRing 2 } -- Metro Ring Global Scalar Object Section -- Metro Ring Table Object Section -- -- Metro Ring Table -- snMetroRingTable OBJECT-TYPE SYNTAX SEQUENCE OF SnMetroRingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Metro ring table." ::= { snMetroRingTableObjects 1 } snMetroRingEntry OBJECT-TYPE SYNTAX SnMetroRingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the metro ring table." INDEX { snMetroRingVLanId, snMetroRingId } ::= { snMetroRingTable 1 } SnMetroRingEntry ::= SEQUENCE { snMetroRingVLanId Integer32, snMetroRingId Integer32, snMetroRingConfigState INTEGER, snMetroRingRole INTEGER, snMetroRingHelloTime Integer32, snMetroRingPreforwardingTime Integer32, snMetroRingPort1 InterfaceIndex, snMetroRingPort2 InterfaceIndex, snMetroRingName DisplayString, snMetroRingRowStatus INTEGER, snMetroRingOperState INTEGER, snMetroRingTopoGroupId Integer32, snMetroRingRHPTransmitted Counter32, snMetroRingRHPReceived Counter32, snMetroRingStateChanged Counter32, snMetroRingTCRBPDUReceived Counter32, snMetroRingPriPort InterfaceIndex, snMetroRingSecPort InterfaceIndex, snMetroRingPriPortState INTEGER, snMetroRingSecPortState INTEGER, snMetroRingPriPortType INTEGER, snMetroRingSecPortType INTEGER, snMetroRingPriPortActivePort InterfaceIndex, snMetroRingSecPortActivePort InterfaceIndex } snMetroRingVLanId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Identifier of a VLAN that controls the metro ring." ::= { snMetroRingEntry 1 } snMetroRingId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Metro ring identifier." ::= { snMetroRingEntry 2 } snMetroRingConfigState OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Metro ring state." ::= { snMetroRingEntry 3 } snMetroRingRole OBJECT-TYPE SYNTAX INTEGER { other(1), master(2), member(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Metro ring role. other(1).........none of the cases in below. master(2)........device which originates RHP packets. member(3)........device which forwards RHP packets." ::= { snMetroRingEntry 4 } snMetroRingHelloTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The time interval to periodically transmit ring health protocol (RHP). Each unit is millisecond." ::= { snMetroRingEntry 5 } snMetroRingPreforwardingTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The time interval of which a metro ring port is staying in preforwarding state before changing to forwarding state. Each unit is millisecond." ::= { snMetroRingEntry 6 } snMetroRingPort1 OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-write STATUS current DESCRIPTION "The ifIndex value of port 1 to configure into the metro ring." ::= { snMetroRingEntry 7 } snMetroRingPort2 OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-write STATUS current DESCRIPTION "The ifIndex value of port 2 to configure into the metro ring." ::= { snMetroRingEntry 8 } snMetroRingName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The metro ring description." ::= { snMetroRingEntry 9 } snMetroRingRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuchName...no such row other(1).....some other cases valid(2)....the row exists and is valid" ::= { snMetroRingEntry 10 } snMetroRingOperState OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Metro ring operational state." ::= { snMetroRingEntry 11 } snMetroRingTopoGroupId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Topology group ID that controls the metro ring." ::= { snMetroRingEntry 12 } snMetroRingRHPTransmitted OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Ring health protocol (RHP) transmitted counter." ::= { snMetroRingEntry 13 } snMetroRingRHPReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Ring health protocol (RHP) received counter." ::= { snMetroRingEntry 14 } snMetroRingStateChanged OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Ring state changed counter." ::= { snMetroRingEntry 15 } snMetroRingTCRBPDUReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Topology change protocol received counter." ::= { snMetroRingEntry 16 } snMetroRingPriPort OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex value of primary port." ::= { snMetroRingEntry 17 } snMetroRingSecPort OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex value of secondary port." ::= { snMetroRingEntry 18 } snMetroRingPriPortState OBJECT-TYPE SYNTAX INTEGER { other(1), preforwarding(2), forwarding(3), blocking(4), disabled(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Metro ring primary port state. other(1)...........none of the cases in below. preforwarding(2)...port transmits RHP packets, port does not transmit data packets. forwarding(3)......port transmits RHP and data packets. blocking(4)........port receives RHP packets, port does not receive data packets. disabled(5)........port is disabled from metro ring." ::= { snMetroRingEntry 19 } snMetroRingSecPortState OBJECT-TYPE SYNTAX INTEGER { other(1), preforwarding(2), forwarding(3), blocking(4), disabled(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Metro ring secondary port state. other(1)...........none of the cases in below. preforwarding(2)...port transmits RHP packets, port does not transmit data packets. forwarding(3)......port transmits RHP and data packets. blocking(4)........port receives RHP packets, port does not receive data packets. disabled(5)........port is disabled from metro ring." ::= { snMetroRingEntry 20 } snMetroRingPriPortType OBJECT-TYPE SYNTAX INTEGER { other(1), regular(2), tunnel(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Metro ring primary port type. other(1).....none of the cases in below. regular(2)...port is configured to operate on a single ring. tunnel(3)....port is configured to operate on multiple rings." ::= { snMetroRingEntry 21 } snMetroRingSecPortType OBJECT-TYPE SYNTAX INTEGER { other(1), regular(2), tunnel(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Metro ring secondary port type. other(1).....none of the cases in below. regular(2)...port is configured to operate on a single ring. tunnel(3)....port is configured to operate on multiple rings." ::= { snMetroRingEntry 22 } snMetroRingPriPortActivePort OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex value of active primary port." ::= { snMetroRingEntry 23 } snMetroRingSecPortActivePort OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex value of active secondary port." ::= { snMetroRingEntry 24 } END