HIMOINSAv14-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString FROM RFC1213-MIB Gauge, Counter, IpAddress FROM RFC1155-SMI; InterfaceIndex ::= INTEGER himoinsa OBJECT IDENTIFIER ::= { enterprises 41809 } measures OBJECT IDENTIFIER ::= { himoinsa 1 } parameters OBJECT IDENTIFIER ::= { himoinsa 2 } traps OBJECT IDENTIFIER ::= { himoinsa 3 } mainsFreq OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 1 } mainsVL12 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 2 } mainsVL23 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 3 } mainsVL13 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 4 } mainsVL1N OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 5 } mainsVL2N OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 6 } mainsVL3N OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 7 } genFreq OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 8 } genVL12 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 9 } genVL23 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 10 } genVL13 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 11 } genVL1N OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 12 } genVL2N OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 13 } genVL3N OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 14 } ph1Amp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 15 } ph2Amp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 16 } ph3Amp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 17 } flagsCurrent OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 18 } pFCTotal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 19 } pFC1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 20 } pFC2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 21 } pFC3 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 22 } realPow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 23 } appPow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 24 } reactivePow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 25 } speed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 26 } fuelLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 27 } altenatorVolt OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 28 } batteryVolt OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 29 } waterTemp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 30 } oilPress OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 31 } oilTemp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 32 } sensorDet OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 33 } units OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 34 } totalInstantPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 35 } partialInstantPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 36 } powerPerDay OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 37 } powerPerMonth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 38 } powerPerYear OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 39 } totalRunningTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 40 } partialRunningTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 41 } successfulStarts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 42 } unsuccessfulStarts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 43 } switchPanelCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 44 } secondaryBatteryVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 45 } status OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 46 } alarmBitMapHigh OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 47 } alarmBitMapLow OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 48 } alarmBitMapHigh1 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 49 } falloArranqueMeasure OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 50 } nivelCombustibleMeasure OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 51 } caidaGrupoMeasure OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 52 } caidaRedMeasure OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 53 } caidaGrupoConmMeasure OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS current DESCRIPTION "" ::= { measures 54 } measuresConmTable OBJECT-TYPE SYNTAX SEQUENCE OF MeasuresConmEntry ACCESS not-accessible STATUS current DESCRIPTION "" ::= { measures 55 } measuresConmEntry OBJECT-TYPE SYNTAX MeasuresConmEntry ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { measuresConmIndex } ::= { measuresConmTable 1 } MeasuresConmEntry ::= SEQUENCE { measuresConmIndex InterfaceIndex, mainsFreqConm INTEGER, mainsVL12Conm INTEGER, mainsVL23Conm INTEGER, mainsVL13Conm INTEGER, mainsVL1NConm INTEGER, mainsVL2NConm INTEGER, mainsVL3NConm INTEGER, genFreqConm INTEGER, genVL12Conm INTEGER, genVL23Conm INTEGER, genVL13Conm INTEGER, genVL1NConm INTEGER, genVL2NConm INTEGER, genVL3NConm INTEGER, ph1AmpConm INTEGER, ph2AmpConm INTEGER, ph3AmpConm INTEGER, flagsCurrentConm Gauge, pFCTotalConm INTEGER, pFC1Conm INTEGER, pFC2Conm INTEGER, pFC3Conm INTEGER, realPowConm INTEGER, appPowConm INTEGER, reactPowConm INTEGER, mainsControlType INTEGER, statusConm Gauge, alarmBitMapConm Gauge } measuresConmIndex OBJECT-TYPE SYNTAX InterfaceIndex ACCESS not-accessible STATUS current DESCRIPTION "" ::= { measuresConmEntry 1 } mainsFreqConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 2 } mainsVL12Conm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 3 } mainsVL23Conm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 4 } mainsVL13Conm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 5 } mainsVL1NConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 6 } mainsVL2NConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 7 } mainsVL3NConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 8 } genFreqConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 9 } genVL12Conm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 10 } genVL23Conm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 11 } genVL13Conm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 12 } genVL1NConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 13 } genVL2NConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 14 } genVL3NConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 15 } ph1AmpConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 16 } ph2AmpConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 17 } ph3AmpConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 18 } flagsCurrentConm OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 19 } pFCTotalConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 20 } pFC1Conm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 21 } pFC2Conm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 22 } pFC3Conm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 23 } realPowConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 24 } appPowConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 25 } reactPowConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 26 } mainsControlType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 27 } statusConm OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 28 } alarmBitMapConm OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS current DESCRIPTION "" ::= { measuresConmEntry 29 } startsCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 1 } timeBetweenStarts OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 2 } startDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 3 } preheatingTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 4 } startupTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 5 } loadActivationTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 6 } nominalConditionTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 7 } dplusActivationTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 8 } eJP1ActivationDelayTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 9 } mainsActivationDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 10 } coolingTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 11 } pEActivationTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 12 } counterDetectionTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 13 } maximumAlarmActivationTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 14 } phaseNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 15 } maxGensetVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 16 } minGensetVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 17 } maxGensetAsymetryValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 18 } maxGensetFrequency OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 19 } minGensetFrequency OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 20 } maxGensetCurrent OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 21 } shortCircuitDetection OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 22 } gensetNominalPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 23 } maxReversePower OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 24 } maxPickupSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 25 } minPickupSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 26 } maxMainsVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 27 } minMainsVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 28 } maxMainsFrequency OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 29 } minMainsFrequency OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 30 } minBatteryVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 31 } transferPumpMinLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 32 } transferPumpMaxLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 33 } startingVoltageGensetSignal OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 34 } startingVoltageAlternator OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 35 } startingSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 36 } engineFlywheelTeeth OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 37 } fuelReserveLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 38 } lowOilPressure OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 39 } highWaterTemperatureThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 40 } lowEngineTemperature OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 41 } minPreheatingTemp OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 42 } maxPreheatingTemp OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 43 } deviceIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 44 } deviceMaskSubnet OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 45 } deviceGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 46 } managerAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 47 } agentSNMPPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 48 } managertrapsPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 49 } reset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 50 } version OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "" ::= { parameters 51 } gensetStartStop OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 52 } gensetMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 53 } mainsBreakerStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 54 } gensetBreakerStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parameters 55 } parametersConmTable OBJECT-TYPE SYNTAX SEQUENCE OF ParametersConmEntry ACCESS not-accessible STATUS current DESCRIPTION "" ::= { parameters 56 } parametersConmEntry OBJECT-TYPE SYNTAX ParametersConmEntry ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { parametersConmIndex } ::= { parametersConmTable 1 } ParametersConmEntry ::= SEQUENCE { parametersConmIndex InterfaceIndex, phaseNumberConm INTEGER, maxGensetVoltageConm INTEGER, minGensetVoltageConm INTEGER, maxGensetAsymetryValueConm INTEGER, maxGensetFrequencyConm INTEGER, minGensetFrequencyConm INTEGER, maxGensetCurrentConm INTEGER, shortCircuitDetectionConm INTEGER, gensetNominalPowerConm INTEGER, maxReversePowerConm INTEGER, maxPickupSpeedConm INTEGER, minPickupSpeedConm INTEGER, maxMainsVoltageConm INTEGER, minMainsVoltageConm INTEGER, maxMainsFrequencyConm INTEGER, minMainsFrequencyConm INTEGER, startingVoltageValueConm INTEGER } parametersConmIndex OBJECT-TYPE SYNTAX InterfaceIndex ACCESS not-accessible STATUS current DESCRIPTION "" ::= { parametersConmEntry 1 } phaseNumberConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parametersConmEntry 2 } maxGensetVoltageConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parametersConmEntry 3 } minGensetVoltageConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parametersConmEntry 4 } maxGensetAsymetryValueConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parametersConmEntry 5 } maxGensetFrequencyConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parametersConmEntry 6 } minGensetFrequencyConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parametersConmEntry 7 } maxGensetCurrentConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parametersConmEntry 8 } shortCircuitDetectionConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parametersConmEntry 9 } gensetNominalPowerConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parametersConmEntry 10 } maxReversePowerConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parametersConmEntry 11 } maxPickupSpeedConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parametersConmEntry 12 } minPickupSpeedConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parametersConmEntry 13 } maxMainsVoltageConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parametersConmEntry 14 } minMainsVoltageConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parametersConmEntry 15 } maxMainsFrequencyConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parametersConmEntry 16 } minMainsFrequencyConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parametersConmEntry 17 } startingVoltageValueConm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "" ::= { parametersConmEntry 18 } alarmString OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { traps 1 } falloArranque OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { traps 2 } nivelCombustible OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { traps 4 } caidaGrupo OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { traps 6 } caidaRed OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { traps 8 } caidaGrupoConm OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { traps 10 } END