-- HP Enterprise Switch Configuration MIB CONFIG-MIB DEFINITIONS ::= BEGIN IMPORTS IpAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 dot1dStpPortState, dot1dStpPortDesignatedBridge, dot1dStpPortDesignatedPort FROM BRIDGE-MIB -- RFC-1493 DisplayString, RowStatus, MacAddress, TimeStamp FROM SNMPv2-TC HpSwitchPortType, ConfigStatus FROM HP-ICF-TC hpSwitch FROM HP-ICF-OID InetAddressType, InetAddress FROM INET-ADDRESS-MIB; -- type. Timeout ::= INTEGER -- a STP timer in units of 1/100 seconds -- Icf Switch Specific hpConfig OBJECT IDENTIFIER ::= { hpSwitch 7 } VlanID ::= INTEGER (1..65535) -- ########################################################### -- the hpConfig Group -- This group contains switch configuration related variables. -- ########################################################### hpSwitchConfig OBJECT IDENTIFIER ::= { hpConfig 1 } hpSwitchSystemConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 1 } hpSwitchAutoReboot OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If the value of this variable was set to yes(1), booting will conditionally enable all application modules-the spanning tree, IP and IPX etc.. Otherwise every application module must be manually enabled through Network Control Language Interpreter's ENABLE command." ::= { hpSwitchSystemConfig 1 } hpSwitchTimeZone OBJECT-TYPE SYNTAX INTEGER (-720..840) ACCESS read-write STATUS mandatory DESCRIPTION "The number of minutes to the east of Greenwich Mean Time(GMT). For a location west of GMT, use a negative integer." ::= { hpSwitchSystemConfig 2 } hpSwitchDaylightTimeRule OBJECT-TYPE SYNTAX INTEGER { none(1), alaska(2), canadaAndContinentalUS(3), middleEuropeAndPortugal(4), southernHemisphere(5), westernEurop(6), userDefined(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The daylight savings time rule for use by the Internet's RFC 868 Time protocol." ::= { hpSwitchSystemConfig 3 } hpSwitchDaylightBeginningMonth OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-write STATUS mandatory DESCRIPTION "The month that daylight saving time starts if DaylightTimeRule is set to userDefined." ::= { hpSwitchSystemConfig 4 } hpSwitchDaylightBeginningDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "The day of the month that daylight saving time starts if DaylightTimeRule is set to userDefined." ::= { hpSwitchSystemConfig 5 } hpSwitchDaylightEndingMonth OBJECT-TYPE SYNTAX INTEGER (1..12) ACCESS read-write STATUS mandatory DESCRIPTION "The month that daylight saving time ends if DaylightTimeRule is set to userDefined." ::= { hpSwitchSystemConfig 6 } hpSwitchDaylightEndingDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "The day of the month that daylight saving time emds if DaylightTimeRule is set to userDefined." ::= { hpSwitchSystemConfig 7 } hpSwitchSystemConfigStatus OBJECT-TYPE SYNTAX ConfigStatus ACCESS read-only STATUS mandatory DESCRIPTION "The configuration status of this group of objects. If one or more variables in this group were reconfigurated since last reboot and required reboot to take effect, the value of this variable will be set to notInService." ::= { hpSwitchSystemConfig 8 } hpSwitchSystemPortLEDMode OBJECT-TYPE SYNTAX INTEGER { link-activity(1), link-only(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The mode of the port LED can be either link/activity (link for 3 seconds then activity thereafter) or link-only." ::= { hpSwitchSystemConfig 9 } hpSwitchControlUnknownIPMulticast OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled along with IGMP, any IP Multicast packets that are not already controlled by IGMP will be restricted to ports that have detected a multicast router or ports configured to always forward IP multicast. When set to disabled or when IGMP is disabled, the unknown IP Multicast packets will be flooded out all ports in the VLAN" ::= { hpSwitchSystemConfig 10 } hpSwitchIgmpDelayedGroupFlushTimer OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This feature is disabled by default, which is indicated by a timer value of 0 seconds. When IGMP is enabled and the value of the Delayed Group Flush Timer is not zero, traffic filters for any previously-joined IGMP groups which no longer have active members will persist for the number of seconds indicated by the timer. This has the effect of dropping any additional unjoined traffic for an empty group until the Delayed Group Flush Timer expires, at which time the traffic filter is then removed." ::= { hpSwitchSystemConfig 11 } hpSwitchMaxFrameSize OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This is the value of the global jumbos max-frame-size supported by the switch. The default value for this is set to 9216, in order to make it compatible with previous versions of software. This configuration does not take a reboot to take effect." ::= { hpSwitchSystemConfig 12 } hpSwitchIpMTU OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This is the value of the global jumbos IP MTU or L3 MTU supported by the switch. The default value for this is set to 9198, in order to make it compatible with previous versions of software. This configuration does not take a reboot to take effect." ::= { hpSwitchSystemConfig 13 } hpSwitchConsoleConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 2 } hpSwitchTelnetAdminStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS obsolete DESCRIPTION "The status of the console telnet operation." ::= { hpSwitchConsoleConfig 1 } hpSwitchTerminalType OBJECT-TYPE SYNTAX INTEGER { vt100(2), ansi(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Terminal type of the console device." ::= { hpSwitchConsoleConfig 2 } hpSwitchConsoleRefRate OBJECT-TYPE SYNTAX INTEGER { refRate1(1), refRate3(3), refRate5(5), refRate10(10), refRate20(20), refRate30(30), refRate45(45), refRate(60) } ACCESS read-write STATUS mandatory DESCRIPTION "The rate, in second per cycle, at which the display of various switch measurements." ::= { hpSwitchConsoleConfig 3 } hpSwitchDisplayedEvent OBJECT-TYPE SYNTAX INTEGER { none(1), major(2), notInfo(3), all(4), debug(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of event messages are automatically displayed on the console." ::= { hpSwitchConsoleConfig 4 } hpSwitchConsoleConfigStatus OBJECT-TYPE SYNTAX ConfigStatus ACCESS read-only STATUS mandatory DESCRIPTION "The configuration status of this group of objects. If one or more variables in this group were reconfigurated since last reboot and required reboot to take effect, the value of this variable will be set to notInService." ::= { hpSwitchConsoleConfig 5 } hpSwitchPortConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 3 } hpSwitchPortTable OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains information about the current port status in this device." ::= { hpSwitchPortConfig 1 } hpSwitchPortEntry OBJECT-TYPE SYNTAX HpSwitchPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about a specific port status in this device." INDEX { hpSwitchPortIndex } ::= { hpSwitchPortTable 1 } HpSwitchPortEntry ::= SEQUENCE { hpSwitchPortIndex INTEGER, hpSwitchPortType HpSwitchPortType, hpSwitchPortDescr DisplayString, hpSwitchPortAdminStatus INTEGER, hpSwitchPortEtherMode INTEGER, hpSwitchPortVgMode INTEGER, hpSwitchPortLinkbeat INTEGER, hpSwitchPortTrunkGroup INTEGER, hpSwitchPortBcastLimit INTEGER, hpSwitchPortFastEtherMode INTEGER, hpSwitchPortFlowControl INTEGER, -- hpSwitchPortBcastPktLimit INTEGER, hpSwitchPortTrunkType INTEGER, hpSwitchPortTrunkLACPStatus INTEGER, hpSwitchPortMDIXStatus INTEGER, hpSwitchPortAutoMDIX INTEGER } hpSwitchPortIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex value which uniquely identifies a row in the Interfaces Table." ::= { hpSwitchPortEntry 1 } hpSwitchPortType OBJECT-TYPE SYNTAX HpSwitchPortType ACCESS read-only STATUS mandatory DESCRIPTION "The type of port." ::= { hpSwitchPortEntry 2 } hpSwitchPortDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A textual string containing information about the interface." ::= { hpSwitchPortEntry 3 } hpSwitchPortAdminStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS obsolete DESCRIPTION "The desired state of the interface. This variable is similar to the ifAdminStatus but instead of keeping the operational status, this variable maintain the desired state in the configuration data base." ::= { hpSwitchPortEntry 4 } hpSwitchPortEtherMode OBJECT-TYPE SYNTAX INTEGER { half-duplex(1), full-duplex(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of transmission on this port. This variable is valid only if the hpSwitchPortType was Ethernet." ::= { hpSwitchPortEntry 5 } hpSwitchPortVgMode OBJECT-TYPE SYNTAX INTEGER { master(1), endNode(2), autoDetect(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of transmission on this port. This variable is valid only if the hpSwitchPortType was VG." ::= { hpSwitchPortEntry 6 } hpSwitchPortLinkbeat OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The linkbeat status of this port." ::= { hpSwitchPortEntry 7 } hpSwitchPortTrunkGroup OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The trunk group this port belong to." ::= { hpSwitchPortEntry 8 } hpSwitchPortBcastLimit OBJECT-TYPE SYNTAX INTEGER (0..99) ACCESS read-write STATUS mandatory DESCRIPTION "The percentage of network bandwidth consumed by broadcast traffic through this port. If the value of this variable is 0, there will be no broadcast limit." ::= { hpSwitchPortEntry 9 } hpSwitchPortFastEtherMode OBJECT-TYPE SYNTAX INTEGER { half-duplex-10Mbits(1), half-duplex-100Mbits(2), full-duplex-10Mbits(3), full-duplex-100Mbits(4), auto-neg(5), full-duplex-1000Mbits(6), auto-10Mbits(7), auto-100Mbits(8), auto-1000Mbits(9), full-duplex-10Gbits(10), auto-10-100Mbits(11) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of transmission on this port. This variable is valid only if the hpSwitchPortType was Fast Ethernet." ::= { hpSwitchPortEntry 10 } hpSwitchPortFlowControl OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The Flow Control of this port." ::= { hpSwitchPortEntry 11} -- hpSwitchPortBcastPktLimit OBJECT-TYPE -- SYNTAX INTEGER (0..1500000) -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION "Network bandwidth in packets per second consumed -- by broadcast traffic through this port. If the value -- of this variable is 0, there will be no broadcast -- limit." -- ::= { hpSwitchPortEntry 12 } hpSwitchPortTrunkType OBJECT-TYPE SYNTAX INTEGER { trunk(1), fecAuto(2), saTrunk(3), lacpTrk(4), none(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Used in conjunction with hpSwitchPortTrunkGroup to determine what type of trunk and which group it belongs to. If hpSwitchPortTrunkGroup is set to 0, trunking is disabled on the port and this variable becomes a 'don't care'" ::= { hpSwitchPortEntry 13 } hpSwitchPortTrunkLACPStatus OBJECT-TYPE SYNTAX INTEGER { disabled(1), active(2), passive(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Used in conjunction with hpSwitchPortTrunkType. When the trunk is a LACP trunk, this variable defines its administrative status" ::= { hpSwitchPortEntry 14 } hpSwitchPortMDIXStatus OBJECT-TYPE SYNTAX INTEGER { not-applicable(1), mdi(2), mdix(3), automdix(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Shows the MDI/MDIX setting for an RJ-45 port. Returns a value of 'not-applicable' for all ports except RJ-45 ports." ::= { hpSwitchPortEntry 15 } hpSwitchPortAutoMDIX OBJECT-TYPE SYNTAX INTEGER { not-applicable(1), mdi(2), mdix(3), automdix(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the MDI/MDIX value for an RJ-45 port. Negates need for crossover cables. 'automdix', 'mdi', or 'mdix' may be set when the port configuration is set to any auto-negotiation mode, for example 'auto' or 'auto-100', or to any of the fixed-configuration modes, for example '100-full'. The MDI/MDIX value is maintained across port configuration mode changes." ::= { hpSwitchPortEntry 16 } hpSwitchPortConfigStatus OBJECT-TYPE SYNTAX ConfigStatus ACCESS read-only STATUS mandatory DESCRIPTION "The configuration status of this group of objects. If one or more variables in this group were reconfigured since last reboot and required reboot to take effect, the value of this variable will be set to notInService." ::= { hpSwitchPortConfig 2 } hpSwitchIpxConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 4 } hpSwitchIpxConfigStatus OBJECT-TYPE SYNTAX ConfigStatus ACCESS read-only STATUS mandatory DESCRIPTION "The status of the IPX configuration table." ::= { hpSwitchIpxConfig 2 } hpSwitchIpConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 5 } hpSwitchIpTimepAdminStatus OBJECT-TYPE SYNTAX INTEGER { manual(1), disable(2), dhcp(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The operational status of the Time protocol." ::= { hpSwitchIpConfig 1 } hpSwitchIpTimepServerAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS deprecated DESCRIPTION "### deprecated ### The IP address of the Time server." ::= { hpSwitchIpConfig 2 } hpSwitchIpTimepPollInterval OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The client poll interval of the Time server in minutes." ::= { hpSwitchIpConfig 3 } hpSwitchIpConfigStatus OBJECT-TYPE SYNTAX ConfigStatus ACCESS read-only STATUS obsolete DESCRIPTION "The configuration status of the Timep and IP related objects." ::= { hpSwitchIpConfig 5 } hpSwitchIpTftpMode OBJECT-TYPE SYNTAX INTEGER { secure(1), unsecure(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The operational mode of the Tftp protocol." ::= { hpSwitchIpConfig 6 } hpSwitchIpTimepInetServerAddrType OBJECT-TYPE SYNTAX InetAddressType ACCESS read-write STATUS mandatory DESCRIPTION "The IP address type of the Time server." ::= { hpSwitchIpConfig 7 } hpSwitchIpTimepInetServerAddr OBJECT-TYPE SYNTAX InetAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address (of the Time server)to which this entry's addressing information pertains. hpSwitchIpTimepInetServerAddr is always interpreted within the context of hpSwitchIpTimepInetServerAddrType." ::= { hpSwitchIpConfig 8 } hpSwitchSerialLinkConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 6 } hpSwitchSLinkBaudRate OBJECT-TYPE SYNTAX INTEGER { speedSense(1), baudRate300(2), baudRate600(3), baudRate1200(4), baudRate2400(5), baudRate4800(6), baudRate9600(7), baudRate19200(8), baudRate38400(9), baudRate57600(10), baudRate115200(11) } ACCESS read-write STATUS mandatory DESCRIPTION "The rate of data transfer between the console and the node. baudRate1 is speed sense." ::= { hpSwitchSerialLinkConfig 1 } hpSwitchSLinkFlowCtrl OBJECT-TYPE SYNTAX INTEGER { none(1), xonXoff(2), robustXonXoff(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The flow-control mechanism between the console and the switch." ::= { hpSwitchSerialLinkConfig 2 } hpSwitchSLinkConnInactTime OBJECT-TYPE SYNTAX INTEGER (0..120) ACCESS read-write STATUS mandatory DESCRIPTION "The number of minutes to wait after no character was input to log out the console. Valid values are 0 (not to log out of the console for inactivity) through 120 (two hours)." ::= { hpSwitchSerialLinkConfig 3 } hpSwitchSLinkModemConnTime OBJECT-TYPE SYNTAX INTEGER (0..300) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds to wait for data mode and clear to send and receiver ready signals after asserting request to send and terminal ready signals. Valid values are 0 (switch will wait forever for the modem) through 300 (5 minutes)." ::= { hpSwitchSerialLinkConfig 4 } hpSwitchSLinkModemLostRecvTime OBJECT-TYPE SYNTAX INTEGER (0..5000) ACCESS read-write STATUS mandatory DESCRIPTION "The number of milliseconds the receiver ready signal is allowed to drop before the switch will disconnect the modem. Valid values are 0 (the switch will wait forever) through 5000 (5 seconds)." ::= { hpSwitchSerialLinkConfig 5 } hpSwitchSLinkModemDisConnTime OBJECT-TYPE SYNTAX INTEGER (0..60) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds to wait after the modem is disconnected before allowing the modem to be reconnected. Valid values are 0 (allow a connection as soon as possible, the default) through 60 (1 minute)." ::= { hpSwitchSerialLinkConfig 6 } hpSwitchSLinkParity OBJECT-TYPE SYNTAX INTEGER { parityNone(1), parityOdd(2), parityEven(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of parity to use between the console and the node." ::= { hpSwitchSerialLinkConfig 7 } hpSwitchSLinkCharBits OBJECT-TYPE SYNTAX INTEGER { char8Bits(1), char7Bits(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The number of bits per character to use between the console and the node." ::= { hpSwitchSerialLinkConfig 8 } hpSwitchSLinkStopBits OBJECT-TYPE SYNTAX INTEGER { stop1Bits(1), stop1andHalfBits(2), stop2Bits(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The number of stop bots to use when communicating between the console and the node." ::= { hpSwitchSerialLinkConfig 9 } hpSwitchSLinkConfigStatus OBJECT-TYPE SYNTAX ConfigStatus ACCESS read-only STATUS mandatory DESCRIPTION "The configuration status of this group of objects. If one or more variables in this group were reconfigured since last reboot and required reboot to take effect, the value of this variable will be set to notInService." ::= { hpSwitchSerialLinkConfig 10 } hpSwitchFilterConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 8 } -- A sample of the traffic filter -- type MacAddr ProType SrcPort PortMask -- unicast MAC address X port # Bit Mask of ports -- multicast MAC address X X Bit Mask of ports -- port X X port # Bit Mask of ports -- level 3 X protocol X Bit Mask of ports hpSwitchFilterConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchFilterConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains information about the traffic filter configuration in this device." ::= { hpSwitchFilterConfig 1 } hpSwitchFilterConfigEntry OBJECT-TYPE SYNTAX HpSwitchFilterConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about a traffic filter configuration in this device." INDEX { hpSwitchFilterIndex } ::= { hpSwitchFilterConfigTable 1 } HpSwitchFilterConfigEntry ::= SEQUENCE { hpSwitchFilterIndex INTEGER, hpSwitchFilterType INTEGER, hpSwitchFilterSrcPort INTEGER, hpSwitchFilterMacAddr MacAddress, hpSwitchFilterProtocolType INTEGER, hpSwitchFilterPortMask OCTET STRING, hpSwitchFilterEntryStatus RowStatus } hpSwitchFilterIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies a traffic filter for which this entry contains information." ::= { hpSwitchFilterConfigEntry 1 } hpSwitchFilterType OBJECT-TYPE SYNTAX INTEGER { multicast(1), level-3(2), port(3), unicast(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of filter." ::= { hpSwitchFilterConfigEntry 2 } hpSwitchFilterSrcPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This variable is required when a port filter or unicast filter was configurated. It will be ignored otherwise." ::= { hpSwitchFilterConfigEntry 3 } hpSwitchFilterMacAddr OBJECT-TYPE SYNTAX MacAddress ACCESS read-write STATUS mandatory DESCRIPTION "This variable is valid only if a unicast or multicast filter was defined. It will be ignored otherwise." ::= { hpSwitchFilterConfigEntry 4 } hpSwitchFilterProtocolType OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This variable is valid only if a level-3 filter was defined. It will be ignored otherwise. This variable will contain either a etherType (DIX Ethernet) or SAP(IEEE 802) value of the level-3 protocol." ::= { hpSwitchFilterConfigEntry 5 } hpSwitchFilterPortMask OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable specifies a group of ports whose traffic will be filtered. Each octet within the value of this object specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the most significant bit represents the lowest numbered port, and the least significant bit represents the highest numbered port. Thus, each port of the switch is represented by a single bit within the value of this object." ::= { hpSwitchFilterConfigEntry 6 } hpSwitchFilterEntryStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "The status of a filter entry." ::= { hpSwitchFilterConfigEntry 7 } hpSwitchProbeConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 9 } hpSwitchProbeType OBJECT-TYPE SYNTAX INTEGER { ports(1), vlan(2) } ACCESS read-write STATUS obsolete DESCRIPTION "If the value of this variable is equal to 1, the probe will monitor those ports specified by hpSwitchProbedPortMask, otherwise all of the port belong to the virtual LAN specified by hpSwitchProbedVlanId will be monitored." ::= { hpSwitchProbeConfig 1 } hpSwitchProbedVlanId OBJECT-TYPE SYNTAX VlanID ACCESS read-write STATUS obsolete DESCRIPTION "The probed virtual LAN." ::= { hpSwitchProbeConfig 2 } hpSwitchProbePort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS obsolete DESCRIPTION "The port that every packet passes through those probed ports will be copied to." ::= { hpSwitchProbeConfig 3 } hpSwitchProbeAdminStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS obsolete DESCRIPTION "The operational status of the probing function" ::= { hpSwitchProbeConfig 4 } hpSwitchProbedPortMask OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS obsolete DESCRIPTION "This variable specifies a group of ports which will be probed. Each octet within the value of this object specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the most significant bit represents the lowest numbered port, and the least significant bit represents the highest numbered port. Thus, each port of the switch is represented by a single bit within the value of this object." ::= { hpSwitchProbeConfig 5 } -- The FDDI IP Fragmention Configuration group hpSwitchFddiIpFragConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 11 } -- The FDDI IP Fragmention Configuration Table hpSwitchFddiIpFragConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchFddiIpFragConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of IP fragmentation configuration parameters for the FDDI cards in the switch." ::= { hpSwitchFddiIpFragConfig 1 } hpSwitchFddiIpFragConfigEntry OBJECT-TYPE SYNTAX HpSwitchFddiIpFragConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Fddi IP fragmentation entry which is containing configurable options for the FDDI cards in the switch." INDEX { hpSwitchFddiIpFragConfigIndex } ::= { hpSwitchFddiIpFragConfigTable 1 } HpSwitchFddiIpFragConfigEntry ::= SEQUENCE { hpSwitchFddiIpFragConfigIndex INTEGER, hpSwitchFddiIpFragConfigStatus INTEGER } hpSwitchFddiIpFragConfigIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each FDDI Card. The value for each FDDI card must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { hpSwitchFddiIpFragConfigEntry 1 } hpSwitchFddiIpFragConfigStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The operational status of FDDI IP fragmentation for each FDDI card. enable(1): FDDI card will fragment all packets which are bigger then the Ethernet packet size limitation, 1518 Bytes. disable(2): FDDI card will drop all packets which are bigger then the Ethernet packet size limitation, 1518 Bytes." ::= { hpSwitchFddiIpFragConfigEntry 2 } hpSwitchABCConfig OBJECT IDENTIFIER ::= {hpSwitchConfig 12 } hpSwitchABCConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchABCConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of Automatic Broadcast Control (ABC disable/enable entries for each VLAN on the switch." ::= { hpSwitchABCConfig 1 } hpSwitchABCConfigEntry OBJECT-TYPE SYNTAX HpSwitchABCConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Contains the ABC status for each VLAN on the switch, including IP RIP control and IPX RIP/SAP control." INDEX { hpSwitchABCConfigVlan } ::= { hpSwitchABCConfigTable 1 } HpSwitchABCConfigEntry ::= SEQUENCE { hpSwitchABCConfigVlan VlanID, hpSwitchABCConfigControl INTEGER, hpSwitchABCConfigIpRipControl INTEGER, hpSwitchABCConfigIpxRipSapControl INTEGER, hpSwitchABCConfigVlanBcastLimit INTEGER, -- hpSwitchABCConfigVlanBcastPktLimit INTEGER, hpSwitchABCConfigAutoGatewayConfig INTEGER } hpSwitchABCConfigVlan OBJECT-TYPE SYNTAX VlanID ACCESS read-only STATUS mandatory DESCRIPTION "The user is able to enable/disable ABC on a per VLAN basis, so the VLAN serves as an index into the ABC configuration table." ::= { hpSwitchABCConfigEntry 1 } hpSwitchABCConfigControl OBJECT-TYPE SYNTAX INTEGER { ipipx(1), ip(2), ipx(3), disable(4) } ACCESS read-write STATUS mandatory DESCRIPTION "ABC control is either IP&IPX or IP or IPX or disabled for each VLAN on the switch." ::= { hpSwitchABCConfigEntry 2 } hpSwitchABCConfigIpRipControl OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "IP RIP control. If this feature is enabled then IP RIP packets will only be forwarded on ports, within its VLAN domain, that have heard RIPs before. If this feature is disabled then IP RIP packets seen by a given port will be forwarded to all ports within its VLAN domain." ::= { hpSwitchABCConfigEntry 3 } hpSwitchABCConfigIpxRipSapControl OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "IPX RIP/SAP control. If this feature is enabled then IPX RIP/SAP packets will only be forwarded on ports, within its VLAN domain, that have previously seen RIP/SAP packets. If this feature is disabled then IPX RIP and SAP packets seen by a given port will be forwarded to all ports within its VLAN domain." ::= { hpSwitchABCConfigEntry 4 } hpSwitchABCConfigVlanBcastLimit OBJECT-TYPE SYNTAX INTEGER (0..99) ACCESS read-write STATUS mandatory DESCRIPTION "The percentage of network bandwidth consumed by broadcast traffic through VLAN. If the value of this variable is 0, there will be no broadcast limit. There is a default value chosen when ABC is enabled." ::= { hpSwitchABCConfigEntry 5 } -- hpSwitchABCConfigVlanBcastPktLimit OBJECT-TYPE -- SYNTAX INTEGER (0..2147483647) -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION "Network bandwidth in packets per second consumed -- by broadcast traffic through VLAN. If the value of -- this variable is 0, there will be no broadcast limit. -- There is a default value chosen when ABC is enabled." -- ::= { hpSwitchABCConfigEntry 6 } hpSwitchABCConfigAutoGatewayConfig OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If this feature is enabled then DHCP packets both ucast and bcast with UDP destination port 68 will be intercepted. DHCP packets with the router option in the options field in the DHCP message will be modified so that the first daddress in the router option is the same as the clients address. Thus the client will be its own default gateway. If this feature is disabled DHCP packtes will be forwarded as usual." ::= { hpSwitchABCConfigEntry 7 } hpSwitchStpConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 14 } hpSwitchStpVlanTable OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchStpVlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains vlan-specific information for the Spanning Tree Protocol." ::= { hpSwitchStpConfig 1} hpSwitchStpVlanEntry OBJECT-TYPE SYNTAX HpSwitchStpVlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of information maintained by every port about the Spanning Tree Protocol state for that port." INDEX { hpSwitchStpVlan } ::= { hpSwitchStpVlanTable 1 } HpSwitchStpVlanEntry ::= SEQUENCE { hpSwitchStpVlan VlanID, hpSwitchStpAdminStatus INTEGER, hpSwitchStpPriority INTEGER, hpSwitchStpMaxAge Timeout, hpSwitchStpHelloTime Timeout, hpSwitchStpForwardDelay Timeout } hpSwitchStpVlan OBJECT-TYPE SYNTAX VlanID ACCESS read-only STATUS mandatory DESCRIPTION "The operational status of the spanning tree protocol." ::= { hpSwitchStpVlanEntry 1 } hpSwitchStpAdminStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The operational status of the spanning tree protocol." ::= { hpSwitchStpVlanEntry 2 } hpSwitchStpPriority OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The value of the write-able portion of the Bridge ID, i.e., the first two octets of the (8 octet long) Bridge ID. The other (last) 6 octets of the Bridge ID are given by the value of dot1dBaseBridgeAddress." REFERENCE "IEEE 802.1D-1990: Section 4.5.3.7" ::= { hpSwitchStpVlanEntry 3 } hpSwitchStpMaxAge OBJECT-TYPE SYNTAX Timeout ACCESS read-write STATUS mandatory DESCRIPTION "The maximum age of Spanning Tree Protocol information learned from the network on any port before it is discarded, in units of hundredths of a second. This is the actual value that this bridge is currently using." REFERENCE "IEEE 802.1D-1990: Section 4.5.3.4" ::= { hpSwitchStpVlanEntry 4 } hpSwitchStpHelloTime OBJECT-TYPE SYNTAX Timeout ACCESS read-write STATUS mandatory DESCRIPTION "The amount of time between the transmission of Configuration bridge PDUs by this node on any port when it is the root of the spanning tree or trying to become so, in units of hundredths of a second. This is the actual value that this bridge is currently using." REFERENCE "IEEE 802.1D-1990: Section 4.5.3.5" ::= { hpSwitchStpVlanEntry 5 } hpSwitchStpForwardDelay OBJECT-TYPE SYNTAX Timeout ACCESS read-write STATUS mandatory DESCRIPTION "This time value, measured in units of hundredths of a second, controls how fast a port changes its spanning state when moving towards the Forwarding state. The value determines how long the port stays in each of the Listening and Learning states, which precede the Forwarding state. This value is also used, when a topology change has been detected and is underway, to age all dynamic entries in the Forwarding Database. [Note that this value is the one that this bridge is currently using, in contrast to dot1dBridgeForwardDelay which is the value that this bridge and all others would start using if/when this bridge were to become the root.]" REFERENCE "IEEE 802.1D-1990: Section 4.5.3.6" ::= { hpSwitchStpVlanEntry 6 } hpSwitchStpPortTable OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchStpPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains port-specific information for the Spanning Tree Protocol." ::= { hpSwitchStpConfig 2 } hpSwitchStpPortEntry OBJECT-TYPE SYNTAX HpSwitchStpPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of information maintained by every port about the Spanning Tree Protocol state for that port." INDEX { hpSwitchStpPort } ::= { hpSwitchStpPortTable 1 } HpSwitchStpPortEntry ::= SEQUENCE { hpSwitchStpPort INTEGER, hpSwitchStpPortType HpSwitchPortType, hpSwitchStpPortSrcMac MacAddress, hpSwitchStpPortPriority INTEGER, hpSwitchStpPortPathCost INTEGER, hpSwitchStpPortMode INTEGER, hpSwitchStpPortBpduFilter INTEGER, hpSwitchStpPortBpduProtection INTEGER, hpSwitchStpPortErrantBpduCounter Counter, hpSwitchStpPortPvstFilter INTEGER, hpSwitchStpPortPvstProtection INTEGER } hpSwitchStpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The port number of the port for which this entry contains Spanning Tree Protocol management information." REFERENCE "IEEE 802.1D-1990: Section 6.8.2.1.2" ::= { hpSwitchStpPortEntry 1 } hpSwitchStpPortType OBJECT-TYPE SYNTAX HpSwitchPortType ACCESS read-only STATUS mandatory DESCRIPTION "The type of port." ::= { hpSwitchStpPortEntry 2 } hpSwitchStpPortSrcMac OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "The source MAC address used by the spanning tree protocol." ::= { hpSwitchStpPortEntry 3 } hpSwitchStpPortPriority OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The value of the priority field which is contained in the first (in network byte order) octet of the (2 octet long) Port ID. The other octet of the Port ID is given by the value of dot1dStpPort." REFERENCE "IEEE 802.1D-1990: Section 4.5.5.1" ::= { hpSwitchStpPortEntry 4 } hpSwitchStpPortPathCost OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The contribution of this port to the path cost of paths towards the spanning tree root which include this port. 802.1D-1990 recommends that the default value of this parameter be in inverse proportion to the speed of the attached LAN." REFERENCE "IEEE 802.1D-1990: Section 4.5.5.3" ::= { hpSwitchStpPortEntry 5 } hpSwitchStpPortMode OBJECT-TYPE SYNTAX INTEGER { normal(1), fast(2), uplink(3) } ACCESS read-write STATUS mandatory DESCRIPTION "If the value of this variable is set to fast(2), the port will go directly into the Forwarding State when a device is connected to it. Use this feature only on ports that are connected to an individual PC or Workstation, to allow these ports to come up and move quickly to the Forwarding State instead of going through the normal STP initialization process. Caution: Changing the value of this variable to fast(2) on ports connected to a hub or switch may cause loops in your network." ::= { hpSwitchStpPortEntry 6 } hpSwitchStpPortBpduFilter OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS optional DESCRIPTION "Setting True will cause port to ignore ingress BPDUs and not generate egress BPDUs, as the result the port will stay in forwarding state. Default is False." DEFVAL { false } ::= { hpSwitchStpPortEntry 7 } hpSwitchStpPortBpduProtection OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS optional DESCRIPTION "Setting True indicates that no BPDUs are expected to be received on this port. At the reception of BPDUs the BPDU protection mechanism will disable this port and port will transition into bpduError state. Default is False." DEFVAL { false } ::= { hpSwitchStpPortEntry 8 } hpSwitchStpPortErrantBpduCounter OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS optional DESCRIPTION "Counts the number of BPDUs that were not expected to be received on this port. This counter gets incremented only if hpSwitchStpPortBpduProtection, hpSwitchStpPortBpduFilter, hpSwitchStpPortPvstFilter, or hpSwitchStpPvstProtection is True for the port, otherwise it is cleared to zero." ::= { hpSwitchStpPortEntry 9 } hpSwitchStpPortPvstFilter OBJECT-TYPE SYNTAX TruthValue ACCESS read-write STATUS optional DESCRIPTION "Setting True will cause the port to ignore incoming PVST BPDUs. Default is False." DEFVAL { false } ::= { hpSwitchStpPortEntry 10 } hpSwitchStpPortPvstProtection OBJECT-TYPE SYNTAX TruthValue ACCESS read-write STATUS optional DESCRIPTION "Setting True indicates that any PVST BPDUs arriving on this port should be discarded and that this will cause the port to be disabled. The port will remain disabled for the time period indicated by hpSwitchStpBpduProtectionTimeout. Default is False." DEFVAL { false } ::= { hpSwitchStpPortEntry 11 } hpSwitchStpTrapCntl OBJECT-TYPE SYNTAX BITS { errantBpdu(0) } ACCESS read-write STATUS optional DESCRIPTION "Controls generation of SNMP traps by STP-enabled switch for events defined in this MIB. The set bit means 'enabled'. - errantBpdu(0) The state of this bit specifies whether the notification trap allowed to be send when unexpected (errant) BPDU is received on a port." ::= { hpSwitchStpConfig 3 } hpSwitchStpBpduProtectionTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "The duration of time in seconds when a protected port affected by receiving of an unauthorized BPDU will remain in down state. The zero value means infinity." DEFVAL { 0 } ::= { hpSwitchStpConfig 4 } hpSwitchIgmpConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 15 } hpSwitchIgmpConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchIgmpConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains information about the IGMP Querier capacity or High Priority Forward configuration on any given vlan on the switch." ::= { hpSwitchIgmpConfig 1 } hpSwitchIgmpConfigEntry OBJECT-TYPE SYNTAX HpSwitchIgmpConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about the IGMP Querier feature associated with a specific virtal LAN in this device." INDEX { hpSwitchIgmpVlanIndex } ::= { hpSwitchIgmpConfigTable 1 } HpSwitchIgmpConfigEntry ::= SEQUENCE { hpSwitchIgmpVlanIndex VlanID, hpSwitchIgmpState INTEGER, hpSwitchIgmpQuerierState INTEGER, hpSwitchIgmpPriorityState INTEGER, hpSwitchIgmpQuerierInterval INTEGER } hpSwitchIgmpVlanIndex OBJECT-TYPE SYNTAX VlanID ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies the IGMP configuration of a virtual LAN for which this entry contains information." ::= { hpSwitchIgmpConfigEntry 1 } hpSwitchIgmpState OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The operational status of the IGMP support for this virtual LAN." ::= { hpSwitchIgmpConfigEntry 2 } hpSwitchIgmpQuerierState OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The operational status of the IGMP Querier functionality for this virtual LAN." ::= { hpSwitchIgmpConfigEntry 3 } hpSwitchIgmpPriorityState OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The operational status of the IGMP Forward with High Priority mode for this virtual LAN." ::= { hpSwitchIgmpConfigEntry 4 } hpSwitchIgmpQuerierInterval OBJECT-TYPE SYNTAX INTEGER (5..300) ACCESS read-write STATUS mandatory DESCRIPTION "The time (in seconds) to wait between Querier election cycles for this virtual LAN." ::= { hpSwitchIgmpConfigEntry 5 } hpSwitchIgmpPortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchIgmpPortConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains information about the IGMP port configurations on this switch." ::= { hpSwitchIgmpConfig 2 } hpSwitchIgmpPortConfigEntry OBJECT-TYPE SYNTAX HpSwitchIgmpPortConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The information associated with each IGMP port configuration." INDEX { hpSwitchIgmpPortIndex } ::= { hpSwitchIgmpPortConfigTable 1 } HpSwitchIgmpPortConfigEntry ::= SEQUENCE { hpSwitchIgmpPortIndex INTEGER, hpSwitchIgmpPortType HpSwitchPortType, hpSwitchIgmpIpMcastState INTEGER } hpSwitchIgmpPortIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex value which uniquely identifies a row in the Interfaces Table." ::= { hpSwitchIgmpPortConfigEntry 1 } hpSwitchIgmpPortType OBJECT-TYPE SYNTAX HpSwitchPortType ACCESS read-only STATUS mandatory DESCRIPTION "The type of port." ::= { hpSwitchIgmpPortConfigEntry 2 } hpSwitchIgmpIpMcastState OBJECT-TYPE SYNTAX INTEGER{ auto(1), blocked(2), forward(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The operational status of the IGMP feature for this port or trunk. 1 implies that all IP Multicast traffic will be monitored on the port, 2 implies that IP Multicast traffic will be dropped on the port, and 3 implies that all IP Multicast traffic will be forwarded without the switch examining it." ::= { hpSwitchIgmpPortConfigEntry 3 } hpSwitchIgmpPortConfigTable2 OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchIgmpPortConfigEntry2 ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains information about the IGMP port configurations on this switch. This table supercedes hpSwitchIgmpPortConfigTable for products which support multiple VLANs on each port." ::= { hpSwitchIgmpConfig 3 } hpSwitchIgmpPortConfigEntry2 OBJECT-TYPE SYNTAX HpSwitchIgmpPortConfigEntry2 ACCESS not-accessible STATUS mandatory DESCRIPTION "The information associated with each IGMP port configuration." INDEX { hpSwitchIgmpPortVlanIndex2, hpSwitchIgmpPortIndex2 } ::= { hpSwitchIgmpPortConfigTable2 1 } HpSwitchIgmpPortConfigEntry2 ::= SEQUENCE { hpSwitchIgmpPortVlanIndex2 INTEGER, hpSwitchIgmpPortIndex2 INTEGER, hpSwitchIgmpPortType2 HpSwitchPortType, hpSwitchIgmpIpMcastState2 INTEGER, hpSwitchIgmpPortForcedLeaveState INTEGER, hpSwitchIgmpPortFastLeaveState INTEGER } hpSwitchIgmpPortVlanIndex2 OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The Vlan Index value which uniquely identifies a row in the Interfaces Table." ::= { hpSwitchIgmpPortConfigEntry2 1 } hpSwitchIgmpPortIndex2 OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex value which uniquely identifies a row in the Interfaces Table." ::= { hpSwitchIgmpPortConfigEntry2 2 } hpSwitchIgmpPortType2 OBJECT-TYPE SYNTAX HpSwitchPortType ACCESS read-only STATUS mandatory DESCRIPTION "The type of port." ::= { hpSwitchIgmpPortConfigEntry2 3 } hpSwitchIgmpIpMcastState2 OBJECT-TYPE SYNTAX INTEGER { auto(1), blocked(2), forward(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The operational status of the IGMP feature for this port or trunk. 1 implies that all IP Multicast traffic will be monitored on the port, 2 implies that IP Multicast traffic will be dropped on the port, and 3 implies that all IP Multicast traffic will be forwarded without the switch examining it." ::= { hpSwitchIgmpPortConfigEntry2 4 } hpSwitchIgmpPortForcedLeaveState OBJECT-TYPE SYNTAX INTEGER{ enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The operational status of the IGMP feature for this port or trunk indicates whether any IGMP V2 Leaves received for an IP Multicast group will cause the group to be deleted after the hpSwitchIgmpForcedLeaveInterval if no new IGMP V2 Reports are received for that group. Normal behavior is for a group issuing a Leave to be deleted after the Querier's Maximum Response time if no IGMP V2 Report is received." ::= { hpSwitchIgmpPortConfigEntry2 5 } hpSwitchIgmpPortFastLeaveState OBJECT-TYPE SYNTAX INTEGER{ enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The operational status of the IGMP feature for this port or trunk indicates whether any IGMP V2 Leaves received for an IP Multicast group will cause the group to be deleted immediately on single- connection ports. Normal behavior is for a group issuing a Leave to be deleted after the Querier's Maximum Response time if no IGMP V2 Report is received." ::= { hpSwitchIgmpPortConfigEntry2 6 } hpSwitchIgmpForcedLeaveInterval OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "When a port's hpSwitchIgmpPortForcedLeaveState is enabled, this is the amount of time allowed for an IGMP V2 Report to arrive and cancel deletion of a multicast group requested by a previous IGMP V2 Leave request." ::= { hpSwitchIgmpConfig 4 } -- CoS support MIB definition hpSwitchCosConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 17 } hpSwitchCosPortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchCosPortConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains information about the CoS port configurations on this switch." ::= { hpSwitchCosConfig 1 } hpSwitchCosPortConfigEntry OBJECT-TYPE SYNTAX HpSwitchCosPortConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The information associated with each CoS port configuration." INDEX { hpSwitchCosPortIndex } ::= { hpSwitchCosPortConfigTable 1 } HpSwitchCosPortConfigEntry ::= SEQUENCE { hpSwitchCosPortIndex INTEGER, hpSwitchCosPortType HpSwitchPortType, hpSwitchCosPortPriority INTEGER, hpSwitchCosPortDSCPPolicy INTEGER, hpSwitchCosPortResolvedPriority INTEGER, hpSwitchCosPortApplyPolicy INTEGER } hpSwitchCosPortIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex value which uniquely identifies a row in the Interfaces Table." ::= { hpSwitchCosPortConfigEntry 1 } hpSwitchCosPortType OBJECT-TYPE SYNTAX HpSwitchPortType ACCESS read-only STATUS deprecated DESCRIPTION "The type of port." ::= { hpSwitchCosPortConfigEntry 2 } hpSwitchCosPortPriority OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The 802.1p priority value to assign to packets received on the specified port. This value will be inserted in the 802.1Q tag and the packet will be placed in the appropriate outbound port queue. The value of 255 is used to indicate No Override." ::= { hpSwitchCosPortConfigEntry 3 } hpSwitchCosPortDSCPPolicy OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "The DSCP Policy to assign to packets received on the specified Port. This is an index into the hpSwitchCosDSCPPolicy table, or the value 255 indicating no DSCP Policy exists. This policy is associated with an 802.1p priority value, which will be inserted in the 802.1Q tag and will cause the packet to be placed in the appropriate outbound port queue. When the packet is IP protocol type, the DSCP policy value (a Differentiated Services codepoint) will also be written into the Differentiated-Services field of the IP Type-of-Service byte." ::= { hpSwitchCosPortConfigEntry 4 } hpSwitchCosPortResolvedPriority OBJECT-TYPE SYNTAX INTEGER (0..7 | 255) ACCESS read-only STATUS mandatory DESCRIPTION "The 802.1p priority that will be applied to packets received on the specified port. This value represents the actual operating value for this CoS port entry. A value of 255 represents no override of the incoming priority." ::= { hpSwitchCosPortConfigEntry 5 } hpSwitchCosPortApplyPolicy OBJECT-TYPE SYNTAX INTEGER { noPolicyOverride(1), applyHpSwitchCosPortPriority(2), applyHpSwitchCosPortDSCPPolicy(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object determines which configuration policy, noPolicyOverride, hpSwitchCosPortPriority or hpSwitchCosPortDSCPPolicy, applies for the given Port CoS entry. These configuration policies are mutually exclusive of one another." ::= { hpSwitchCosPortConfigEntry 6 } hpSwitchCosVlanConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchCosVlanConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains information about the CoS Vlan configurations on this switch." ::= { hpSwitchCosConfig 2 } hpSwitchCosVlanConfigEntry OBJECT-TYPE SYNTAX HpSwitchCosVlanConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The information associated with each CoS Vlan configuration." INDEX { hpSwitchCosVlanIndex } ::= { hpSwitchCosVlanConfigTable 1 } HpSwitchCosVlanConfigEntry ::= SEQUENCE { hpSwitchCosVlanIndex VlanID, hpSwitchCosVlanPriority INTEGER, hpSwitchCosVlanDSCPPolicy INTEGER, hpSwitchCosVlanResolvedPriority INTEGER, hpSwitchCosVlanApplyPolicy INTEGER } hpSwitchCosVlanIndex OBJECT-TYPE SYNTAX VlanID ACCESS read-only STATUS mandatory DESCRIPTION "The index that uniquely identifies the CoS configuration of a virtual LAN for which this entry contains information." ::= { hpSwitchCosVlanConfigEntry 1 } hpSwitchCosVlanPriority OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The 802.1p priority value to assign to packets received on the specified Vlan. This value will be inserted in the 802.1Q tag and the packet will be placed in the appropriate outbound port queue. The value of 255 is used to indicate No Override." ::= { hpSwitchCosVlanConfigEntry 2 } hpSwitchCosVlanDSCPPolicy OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "The DSCP Policy to assign to packets received on the specified Vlan. This is an index into the hpSwitchCosDSCPPolicy table, or the value 255 indicating no DSCP Policy exists. This policy is associated with an 802.1p priority value, which will be inserted in the 802.1Q tag and will cause the packet to be placed in the appropriate outbound port queue. When the packet is IP protocol type, the DSCP policy value (a Differentiated Services codepoint) will also be written into the Differentiated-Services field of the IP Type-of-Service byte." ::= { hpSwitchCosVlanConfigEntry 3 } hpSwitchCosVlanResolvedPriority OBJECT-TYPE SYNTAX INTEGER (0..7 | 255) ACCESS read-only STATUS mandatory DESCRIPTION "The 802.1p priority that will be applied to packets received on the specified VLAN. This value represents the actual operating value for this CoS vlan entry. A value of 255 represents no override of the incoming priority ." ::= { hpSwitchCosVlanConfigEntry 4 } hpSwitchCosVlanApplyPolicy OBJECT-TYPE SYNTAX INTEGER { noPolicyOverride(1), applyHpSwitchCosVlanPriority(2), applyHpSwitchCosVlanDSCPPolicy(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object determines which configuration policy, noPolicyOverride, hpSwitchCosVlanPriority or hpSwitchCosDSCPPolicy, applies for this given Vlan CoS entry. These configuration policies are mutually exclusive of one another." ::= { hpSwitchCosVlanConfigEntry 5 } hpSwitchCosProtocolConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchCosProtocolConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains information about the CoS protocol type configurations on this switch." ::= { hpSwitchCosConfig 3 } hpSwitchCosProtocolConfigEntry OBJECT-TYPE SYNTAX HpSwitchCosProtocolConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The information associated with each CoS protocol configuration." INDEX { hpSwitchCosProtocolType } ::= { hpSwitchCosProtocolConfigTable 1 } HpSwitchCosProtocolConfigEntry ::= SEQUENCE { hpSwitchCosProtocolType INTEGER, hpSwitchCosProtocolPriority INTEGER } hpSwitchCosProtocolType OBJECT-TYPE SYNTAX INTEGER { ip(1), ipx(2), arp(3), decnet(4), appletalk(5), sna(6), netbios(7) } ACCESS read-only STATUS mandatory DESCRIPTION "Packets with this protocol type will receive the new priority value." ::= { hpSwitchCosProtocolConfigEntry 1 } hpSwitchCosProtocolPriority OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The 802.1p priority value to assign to packets received for the specified protocol. This value will be inserted in the 802.1Q tag and the packet will be placed in the appropriate outbound port queue. The value of 255 is used to indicate No Override." ::= { hpSwitchCosProtocolConfigEntry 2 } hpSwitchCosAddressConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchCosAddressConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains information about the CoS address configurations on this switch." ::= { hpSwitchCosConfig 4 } hpSwitchCosAddressConfigEntry OBJECT-TYPE SYNTAX HpSwitchCosAddressConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The information associated with each CoS address configuration." INDEX { hpSwitchCosAddressIndex } ::= { hpSwitchCosAddressConfigTable 1 } HpSwitchCosAddressConfigEntry ::= SEQUENCE { hpSwitchCosAddressIndex INTEGER, hpSwitchCosAddressType INTEGER, hpSwitchCosAddressIp IpAddress, hpSwitchCosAddressPriority INTEGER, hpSwitchCosAddressStatus RowStatus, hpSwitchCosAddressDSCPPolicy INTEGER, hpSwitchCosAddressResolvedPriority INTEGER, hpSwitchCosAddressApplyPolicy INTEGER } hpSwitchCosAddressIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index that uniquely identifies the CoS configuration for an address for which this entry contains information." ::= { hpSwitchCosAddressConfigEntry 1 } hpSwitchCosAddressType OBJECT-TYPE SYNTAX INTEGER { ip(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of address to configure." ::= { hpSwitchCosAddressConfigEntry 2 } hpSwitchCosAddressIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "This variable is valid only if an IP CoS configuration was defined. It will be ignored otherwise. Packets with this IP address as a source or destination will receive the new priority value." ::= { hpSwitchCosAddressConfigEntry 3 } hpSwitchCosAddressPriority OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The 802.1p priority value to assign to packets received for the specified address. This value will be inserted in the 802.1Q tag and the packet will be placed in the appropriate outbound port queue." ::= { hpSwitchCosAddressConfigEntry 4 } hpSwitchCosAddressStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "The status of a Cos Address entry." ::= { hpSwitchCosAddressConfigEntry 5 } hpSwitchCosAddressDSCPPolicy OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "The DSCP Policy to assign to packets received for the specified address. This is an index into the hpSwitchCosDSCPPolicy table, or the value 255 indicating no DSCP Policy exists. This policy is associated with an 802.1p priority value, which will be inserted in the 802.1Q tag and will cause the packet to be placed in the appropriate outbound port queue. The DSCP policy value (a Differentiated Services codepoint) will also be written into the Differentiated-Services field of the IP Type-of-Service byte." ::= { hpSwitchCosAddressConfigEntry 6 } hpSwitchCosAddressResolvedPriority OBJECT-TYPE SYNTAX INTEGER (0..7 | 255) ACCESS read-only STATUS mandatory DESCRIPTION "The 802.1p priority that will be applied to packets received for the specified address. This value represents the actual operating value for this given address entry. A value of 255 represents no override." ::= { hpSwitchCosAddressConfigEntry 7 } hpSwitchCosAddressApplyPolicy OBJECT-TYPE SYNTAX INTEGER { applyHpSwitchCosAddressPriority(1), applyHpSwitchCosAddressDSCPPolicy(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object determines which configuration policy, hpSwitchCosAddressPriority or hpSwitchCosDSCPPolicy, applies for the given Address CoS entry. These configuration policies are mutually exclusive of one another." DEFVAL { applyHpSwitchCosAddressPriority } ::= { hpSwitchCosAddressConfigEntry 8 } hpSwitchCosTosConfig OBJECT IDENTIFIER ::= { hpSwitchCosConfig 5 } hpSwitchCosTosConfigMode OBJECT-TYPE SYNTAX INTEGER { disable(1), ipprecedence(2), diffserv(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The operational status of Type of Service based Class of Service." ::= { hpSwitchCosTosConfig 1 } hpSwitchCosTosConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchCosTosConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains information about the CoS Type of Service configurations on this switch. This table is used only when the hpSwitchCosTosConfigMode is set to diffserv." ::= { hpSwitchCosTosConfig 2 } hpSwitchCosTosConfigEntry OBJECT-TYPE SYNTAX HpSwitchCosTosConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The information associated with each CoS TOS configuration." INDEX { hpSwitchCosTosIndex } ::= { hpSwitchCosTosConfigTable 1 } HpSwitchCosTosConfigEntry ::= SEQUENCE { hpSwitchCosTosIndex INTEGER, hpSwitchCosTosPriority INTEGER, hpSwitchCosTosDSCPPolicy INTEGER, hpSwitchCosTosResolvedPriority INTEGER, hpSwitchCosTosApplyPolicy INTEGER } hpSwitchCosTosIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Packets with this value in the upper bits of the Type of Service field of the IP protocol header will receive the new priority value. For Differentiated Services the upper 6 bits of the TOS field are used." ::= { hpSwitchCosTosConfigEntry 1 } hpSwitchCosTosPriority OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS deprecated DESCRIPTION "The 802.1p priority value to assign to packets received for the specified TOS. This value will be inserted in the 802.1Q tag and the packet will be placed in the appropriate outbound port queue. The value of 255 is used to indicate No Override." ::= { hpSwitchCosTosConfigEntry 2 } hpSwitchCosTosDSCPPolicy OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "The DSCP Policy to assign to packets received for the specified ToS codepoint. This is an index into the hpSwitchCosDSCPPolicy table, or the value 255 indicating no DSCP Policy exists. The DSCP policy is associated with an 802.1p priority value, which will be inserted in the 802.1Q tag and will cause the packet to be placed in the appropriate outbound port queue. The DSCP policy value (a Differentiated Services codepoint) will also replace the incoming value of the Differentiated Services field of the IP Type-of-Service byte." ::= { hpSwitchCosTosConfigEntry 3 } hpSwitchCosTosResolvedPriority OBJECT-TYPE SYNTAX INTEGER (0..7 | 255) ACCESS read-only STATUS mandatory DESCRIPTION "The 802.1p priority that will be applied to packets received for the specified ToS. This value represents the actual operating value for this given ToS entry. A value of 255 represents no override of the incoming priority. If hpSwitchCosTosApplyPolicy is set to applyInheritedPriority, the parallel codepoint in the hpSwitchCosDSCPPolicyConfigTable is used to determine the operating priority. Otherwise if set to applyHpSwitchCosTosDSCPPolicy, the priority for the codepoint that the hpSwitchCosTosDSCPPolicy is indexing will be used." ::= { hpSwitchCosTosConfigEntry 4 } hpSwitchCosTosApplyPolicy OBJECT-TYPE SYNTAX INTEGER { applyInheritedPriority(1), applyHpSwitchCosTosDSCPPolicy(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object determines which configuration policy, applyInheritedPriority or hpSwitchCosTosDSCPPolicy, applies for the given Tos CoS entry." DEFVAL { applyInheritedPriority } ::= { hpSwitchCosTosConfigEntry 5 } hpSwitchCosDSCPPolicyConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchCosDSCPPolicyConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains information about the priority applied to each of the Differentiated Services Code Points." ::= { hpSwitchCosConfig 6 } hpSwitchCosDSCPPolicyConfigEntry OBJECT-TYPE SYNTAX HpSwitchCosDSCPPolicyConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of objects describing a DiffServe Codepoint (DSCP), and the 802.1p priority to apply for that DSCP." INDEX { hpSwitchCosDSCPPolicyIndex } ::= { hpSwitchCosDSCPPolicyConfigTable 1 } HpSwitchCosDSCPPolicyConfigEntry ::= SEQUENCE { hpSwitchCosDSCPPolicyIndex INTEGER, hpSwitchCosDSCPPolicyPriority INTEGER, hpSwitchCosDSCPPolicyName OCTET STRING } hpSwitchCosDSCPPolicyIndex OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS not-accessible STATUS mandatory DESCRIPTION "An index to uniquely identify each row in the hpSwitchCosDSCPPolicyConfigTable." ::= { hpSwitchCosDSCPPolicyConfigEntry 1 } hpSwitchCosDSCPPolicyPriority OBJECT-TYPE SYNTAX INTEGER (0..7 | 255) ACCESS read-write STATUS mandatory DESCRIPTION "The 802.1p priority value to assign to packets with a given DSCP. This value will be inserted in the 802.1Q tag and the packet will be placed in the appropriate outbound port queue. The value of 255 is used to indicate no override of the incoming priority." ::= { hpSwitchCosDSCPPolicyConfigEntry 2 } hpSwitchCosDSCPPolicyName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "A user settable name describing a DSCP policy table entry." ::= { hpSwitchCosDSCPPolicyConfigEntry 3 } hpSwitchCosAppTypeConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchCosAppTypeConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains information about the CoS Application type configurations on the switch. An application is determined by its network source and/or destination port number." ::= { hpSwitchCosConfig 7 } hpSwitchCosAppTypeConfigEntry OBJECT-TYPE SYNTAX HpSwitchCosAppTypeConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the switch hpSwitchCosAppTypeConfigEntry Table." INDEX { hpSwitchCosAppTypeConfigIndex } ::= { hpSwitchCosAppTypeConfigTable 1 } HpSwitchCosAppTypeConfigEntry ::= SEQUENCE { hpSwitchCosAppTypeConfigIndex INTEGER, hpSwitchCosAppTypeConfigType INTEGER, hpSwitchCosAppTypeSrcPort INTEGER, hpSwitchCosAppTypeDestPort INTEGER, hpSwitchCosAppTypePriority INTEGER, hpSwitchCosAppTypeDSCPPolicy INTEGER, hpSwitchCosAppTypeResolvedPriority INTEGER, hpSwitchCosAppTypeApplyPolicy INTEGER, hpSwitchCosAppTypeStatus RowStatus, hpSwitchCosAppTypeMaxSrcPort INTEGER, hpSwitchCosAppTypeMaxDestPort INTEGER } hpSwitchCosAppTypeConfigIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS not-accessible STATUS mandatory DESCRIPTION "An index to uniquely identify this hpSwitchCosAppType row." ::= { hpSwitchCosAppTypeConfigEntry 1 } hpSwitchCosAppTypeConfigType OBJECT-TYPE SYNTAX INTEGER { udpSrcPortConfig(1), udpDestPortConfig(2), udpBothPortsConfig(3), tcpSrcPortConfig(4), tcpDestPortConfig(5), tcpBothPortsConfig(6) } ACCESS read-write STATUS mandatory DESCRIPTION "This signifies which network port number to apply to the given CoS Application policy." ::= { hpSwitchCosAppTypeConfigEntry 2 } hpSwitchCosAppTypeSrcPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This object represents the source network port that this policy applies to." ::= { hpSwitchCosAppTypeConfigEntry 3 } hpSwitchCosAppTypeDestPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This object represents the destination network port that this policy applies to." ::= { hpSwitchCosAppTypeConfigEntry 4 } hpSwitchCosAppTypePriority OBJECT-TYPE SYNTAX INTEGER (0..7 | 255) ACCESS read-write STATUS mandatory DESCRIPTION "The 802.1p priority that should be applied to packets containing the particular configured source and/or destination port number in this entry. A value of 255 represents that no priority override should take place." ::= { hpSwitchCosAppTypeConfigEntry 5 } hpSwitchCosAppTypeDSCPPolicy OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "The DSCP Policy to assign to packets received for the specified application. This is an index into the hpSwitchCosDSCPPolicy table, or the value 255 indicating no DSCP Policy exists. This policy is associated with an 802.1p priority value, which will be inserted in the 802.1Q tag and will cause the packet to be placed in the appropriate outbound port queue. The DSCP policy value (a Differentiated Services codepoint) will also be written into the Differentiated-Services field of the IP Type-of-Service byte. The value of 255 is used to indicate No Override." ::= { hpSwitchCosAppTypeConfigEntry 6 } hpSwitchCosAppTypeResolvedPriority OBJECT-TYPE SYNTAX INTEGER (0..7 | 255) ACCESS read-only STATUS mandatory DESCRIPTION "The 802.1p priority that will be applied to packets received on the specified application. This value represents the actual operating value for this CoS application entry. A value of 255 represents no override of the incoming priority" ::= { hpSwitchCosAppTypeConfigEntry 7 } hpSwitchCosAppTypeApplyPolicy OBJECT-TYPE SYNTAX INTEGER { applyHpSwitchCosAppTypePriority(1), applyHpSwitchCosAppTypeDSCPPolicy(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object determines which configuration policy, hpSwitchCosAppTypePriority or hpSwitchCosAppTypeDSCPPolicy, applies for the given AppType CoS entry. These configuration policies are mutually exclusive of one another." DEFVAL { applyHpSwitchCosAppTypePriority } ::= { hpSwitchCosAppTypeConfigEntry 8 } hpSwitchCosAppTypeStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete in the hpSwitchCosAppType table." ::= { hpSwitchCosAppTypeConfigEntry 9 } hpSwitchCosAppTypeMaxSrcPort OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This object represents the maximum source network port that this policy applies to. If a single, specific port is being used and not a range, then value of this object is zero." ::= { hpSwitchCosAppTypeConfigEntry 10 } hpSwitchCosAppTypeMaxDestPort OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This object represents the maximum destination network port that this policy applies to. If a single, specific port is being used and not a range, then value of this object is zero." ::= { hpSwitchCosAppTypeConfigEntry 11 } hpSwitchCosLastChange OBJECT-TYPE SYNTAX TimeStamp ACCESS read-only STATUS mandatory DESCRIPTION "The value of the agent's sysUptime when the last time this device experienced a change in the Class of Service configuration." ::= { hpSwitchCosConfig 8 } hpSwitchConfigCosLastConfigError OBJECT-TYPE SYNTAX INTEGER { aclQosNoError(1), aclQosTooManyRulesError(2), aclQosTooManyMasksError(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of the last QoS configuration result or error. This object is updated for each new QoS configuration. It is reset upon reboot." ::= { hpSwitchCosConfig 9 } hpSwitchMeshConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 18 } hpSwitchMeshMulticastAgingMode OBJECT-TYPE SYNTAX INTEGER { aging(1), nonaging(2) } ACCESS read-write STATUS deprecated DESCRIPTION "With meshing active, a value of aging will cause learned multicast addresses to be aged out within the required address aging interval. A setting of nonaging will prevent learned multicast addresses from being removed from the switch. Multicast addresses learned while in nonaging mode are not removed until the switch is rebooted." ::= { hpSwitchMeshConfig 1 } hpSwitchMeshBackwardCompatibility OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS mandatory DESCRIPTION "Due to some hardware differences, the Series 1600/24xx/4000/8000 switches cannot be used directly in a mesh environment with Series 5300XL switches. Series 5300XL switches need to emulate the operation of Series 1600/24xx/4000/8000 switches in order to have a heterogeneous mesh working properly. Meshing backward-compatibility feature allows Series 5300XL switches to operate in a compatible mode in which the operation of Series 1600/24xx/4000/8000 switches are emulated. When backward-compatibility is enabled, meshing software will establish connections with Series 1600/24xx/4000/8000 switches and emulate their operation. When backward-compatibility disabled, Series 1600/24xx/4000/8000 switches in the mesh will be ignored by the Series 5300XL switches." ::= { hpSwitchMeshConfig 2 } hpSwitchPortIsolationConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 19 } hpSwitchPortIsolationMode OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This enables the port isolation feature on the device. Note: Enabling this feature may require VLANS to be configured properly." ::= { hpSwitchPortIsolationConfig 1 } hpSwitchPortIsolationConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchPortIsolationConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains information about the CoS Application type configurations on the switch. An application is determined by its network source and/or destination port number." ::= { hpSwitchPortIsolationConfig 2 } hpSwitchPortIsolationConfigEntry OBJECT-TYPE SYNTAX HpSwitchPortIsolationConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the switch hpSwitchPortIsolationConfigEntry Table." INDEX { hpSwitchPortIsolationPort } ::= { hpSwitchPortIsolationConfigTable 1 } HpSwitchPortIsolationConfigEntry ::= SEQUENCE { hpSwitchPortIsolationPort INTEGER, hpSwitchPortIsolationPortMode INTEGER } hpSwitchPortIsolationPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the IfIndex table representing a logical port on this switch." ::= { hpSwitchPortIsolationConfigEntry 1 } hpSwitchPortIsolationPortMode OBJECT-TYPE SYNTAX INTEGER { uplink(1), public(2), private(3), local(4), group1(5), group2(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines the operational mode of a port when Port Isolation feature is enabled." ::= { hpSwitchPortIsolationConfigEntry 2 } hpSwitchSshConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 20 } hpSwitchSshAdminStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of the SSH operation." ::= { hpSwitchSshConfig 1 } hpSwitchSshVersion OBJECT-TYPE SYNTAX INTEGER { version1(1), version2(2), version1or2(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The version of the SSH protocol to run. 'version1' will accept connections from v1.3 or v1.5 clients. 'version2' will accept connections only from v2.0 clients. The default is 'version1_or_2' which will accept any connection which can be successfully negotiated." DEFVAL { 1 } ::= { hpSwitchSshConfig 2 } hpSwitchSshTimeout OBJECT-TYPE SYNTAX Timeout (5..120) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum length of time (in seconds) between the wakeup of SSH task and successful protocol negotiation and authentication. The default is 120 seconds." DEFVAL { 120 } ::= { hpSwitchSshConfig 3 } hpSwitchSshPortNumber OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-write STATUS mandatory DESCRIPTION "The port number on which SSH daemon should listen for connection requests." DEFVAL { 22 } ::= { hpSwitchSshConfig 4 } hpSwitchSshServerKeySize OBJECT-TYPE SYNTAX INTEGER { bits512(1), bits768(2), bits1024(3) } MAX-ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the key size (in bits) of version 1 SSH host rsa key" ::= { hpSwitchSshConfig 5 } hpSwitchSshFileServerAdminStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether or not the SSH daemon will accept and process file transfer requests." ::= { hpSwitchSshConfig 6 } hpSwitchSshIpVersion OBJECT-TYPE SYNTAX INTEGER { ipv4(1), ipv6(2), ipv4or6(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The types of IP connections SSH will support. 'ipv4' will accept connections from Ipv4 clients. 'ipv6' will accept connections only from ipv6 clients. The default is 'ipv4or6' which will accept Connections from both ipv4 and ipv6 clients." DEFVAL { 3 } ::= { hpSwitchSshConfig 7 } hpSwitchPendingConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 21 } hpSwitchPendingConfigControl OBJECT-TYPE SYNTAX INTEGER { applyMstp(1), resetMstp(2), noAction(3) } MAX-ACCESS read-write STATUS mandatory DESCRIPTION "The object controls switch pending configuration. If set to the 'applyMstp' value the object applies pending Multiple Spanning Tree Protocol (MSTP) configuration. The 'resetMstp' value, if set, triggers copying of the active MSTP configuration to the pending one. Before the pending configuration is applied its consistency is verified and the request fails if errors are detected. The value the object returns is undefined." ::= { hpSwitchPendingConfig 1 } hpSwitchBWMinConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 22 } hpSwitchBWMinEgressPortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchBWMinEgressPortConfigEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "New definitions under HP-ICF-RATE-LIMIT-MIB. A table that contains information about the port's egress Guaranteed Minimum Bandwidth configurations on this switch." ::= { hpSwitchBWMinConfig 1 } hpSwitchBWMinEgressPortConfigEntry OBJECT-TYPE SYNTAX HpSwitchBWMinEgressPortConfigEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "New definitions under HP-ICF-RATE-LIMIT-MIB. The information associated with each port's egress Guaranteed Minimum Bandwidth configuration." INDEX { hpSwitchBWMinEgressPortIndex } ::= { hpSwitchBWMinEgressPortConfigTable 1 } HpSwitchBWMinEgressPortConfigEntry ::= SEQUENCE { hpSwitchBWMinEgressPortIndex INTEGER, hpSwitchBWMinEgressPortPrctLowPriority INTEGER, hpSwitchBWMinEgressPortPrctNormalPriority INTEGER, hpSwitchBWMinEgressPortPrctMedPriority INTEGER, hpSwitchBWMinEgressPortPrctHighPriority INTEGER } hpSwitchBWMinEgressPortIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS deprecated DESCRIPTION "New definitions under HP-ICF-RATE-LIMIT-MIB. The ifIndex value which uniquely identifies a row in the Interfaces Table." ::= { hpSwitchBWMinEgressPortConfigEntry 1 } hpSwitchBWMinEgressPortPrctLowPriority OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS deprecated DESCRIPTION "New definitions under HP-ICF-RATE-LIMIT-MIB. The percentage of Guaranteed Minimum bandwidth to be assigned to the egress Low-Priority queue for this port. Total values for all four queues must not exceed 100 percent." ::= { hpSwitchBWMinEgressPortConfigEntry 2 } hpSwitchBWMinEgressPortPrctNormalPriority OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS deprecated DESCRIPTION "New definitions under HP-ICF-RATE-LIMIT-MIB. The percentage of Guaranteed Minimum bandwidth to be assigned to the egress Normal-Priority queue for this port. Total values for all four queues must not exceed 100 percent." ::= { hpSwitchBWMinEgressPortConfigEntry 3 } hpSwitchBWMinEgressPortPrctMedPriority OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS deprecated DESCRIPTION "New definitions under HP-ICF-RATE-LIMIT-MIB. The percentage of Guaranteed Minimum bandwidth to be assigned to the egress Medium-Priority queue for this port. Total values for all four queues must not exceed 100 percent." ::= { hpSwitchBWMinEgressPortConfigEntry 4 } hpSwitchBWMinEgressPortPrctHighPriority OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS deprecated DESCRIPTION "New definitions under HP-ICF-RATE-LIMIT-MIB. The percentage of Guaranteed Minimum bandwidth to be assigned to the egress High-Priority queue for this port. Total values for all four queues must not exceed 100 percent." ::= { hpSwitchBWMinEgressPortConfigEntry 5 } hpSwitchRateLimitPortConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 23 } hpSwitchRateLimitPortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchRateLimitPortConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains information about the port Rate-Limiting configurations on this switch." ::= { hpSwitchRateLimitPortConfig 1 } hpSwitchRateLimitPortConfigEntry OBJECT-TYPE SYNTAX HpSwitchRateLimitPortConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The information associated with each port's Rate-Limiting configuration." INDEX { hpSwitchRateLimitPortIndex } ::= { hpSwitchRateLimitPortConfigTable 1 } HpSwitchRateLimitPortConfigEntry ::= SEQUENCE { hpSwitchRateLimitPortIndex INTEGER, hpSwitchRateLimitPortControlMode INTEGER, hpSwitchRateLimitPortSingleControlPrct INTEGER, hpSwitchRateLimitPortPrctLowPriority INTEGER, hpSwitchRateLimitPortPrctNormalPriority INTEGER, hpSwitchRateLimitPortPrctMedPriority INTEGER, hpSwitchRateLimitPortPrctHighPriority INTEGER } hpSwitchRateLimitPortIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex value which uniquely identifies a row in the Interfaces Table." ::= { hpSwitchRateLimitPortConfigEntry 1 } hpSwitchRateLimitPortControlMode OBJECT-TYPE SYNTAX INTEGER { disabled(1), rateLimitPerPortOnly(2), rateLimitPerQueue(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The mode by which this port will be Rate-Limited on ingress. If rateLimitPerPortOnly is configured, there will be a single maximum rate for the entire port. If rateLimitPerQueue is configured, the values for each of the four queues indicate the maximum percentage of port traffic that may be received by that queue (the sum of these values must not exceed 100). When rate-limiting is disabled, there are no maximum controls on ingress for this port." ::= { hpSwitchRateLimitPortConfigEntry 2 } hpSwitchRateLimitPortSingleControlPrct OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "When hpSwitchRateLimitPortControlMode is configured for rateLimitPerPortOnly, this value is the maximum percentage of traffic that may be received by this port on ingress." ::= { hpSwitchRateLimitPortConfigEntry 3 } hpSwitchRateLimitPortPrctLowPriority OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum percentage of traffic that may be received by this port's Low-Priority queue on ingress. hpSwitchRateLimitPortControlMode must be configured to use rateLimitPerQueue for this to take effect. A value of 0-percent for any queue means that no traffic will ever be received on this port for that ingress queue. Total values for all four queues must not exceed 100 percent." ::= { hpSwitchRateLimitPortConfigEntry 4 } hpSwitchRateLimitPortPrctNormalPriority OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum percentage of traffic that may be received by this port's Normal-Priority queue on ingress. hpSwitchRateLimitPortControlMode must be configured to use rateLimitPerQueue for this to take effect. A value of 0-percent for any queue means that no traffic will ever be received on this port for that ingress queue. Total values for all four queues must not exceed 100 percent." ::= { hpSwitchRateLimitPortConfigEntry 5 } hpSwitchRateLimitPortPrctMedPriority OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum percentage of traffic that may be received by this port's Medium-Priority queue on ingress. hpSwitchRateLimitPortControlMode must be configured to use rateLimitPerQueue for this to take effect. A value of 0-percent for any queue means that no traffic will ever be received on this port for that ingress queue. Total values for all four queues must not exceed 100 percent." ::= { hpSwitchRateLimitPortConfigEntry 6 } hpSwitchRateLimitPortPrctHighPriority OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum percentage of traffic that may be received by this port's High-Priority queue on ingress. hpSwitchRateLimitPortControlMode must be configured to use rateLimitPerQueue for this to take effect. A value of 0-percent for any queue means that no traffic will ever be received on this port for that ingress queue. Total values for all four queues must not exceed 100 percent." ::= { hpSwitchRateLimitPortConfigEntry 7 } hpSwitchQosPassThroughMode OBJECT IDENTIFIER ::= { hpSwitchConfig 24 } hpSwitchQosPassThroughModeConfig OBJECT-TYPE SYNTAX INTEGER { optimized (1), typical (2), balanced (3), onequeue (4) } MAX-ACCESS read-write STATUS mandatory DESCRIPTION "Specify the queue configuration mode for the switch. While changing the queue configuration mode this feature momentarily require to bring down the logical port and after the initialisation of the queues the ports are brought up." ::= { hpSwitchQosPassThroughMode 1 } hpSwitchReboot OBJECT IDENTIFIER ::= { hpSwitchConfig 25 } hpSwitchRebootConfig OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } MAX-ACCESS read-only STATUS mandatory DESCRIPTION "This tells the status of the switch whether it requires reboot for some variable to get effective. The value of this variable can be yes (1) reboot is required. no (2) reboot is not required." ::= { hpSwitchReboot 1 } hpSwitchRebootFastBoot OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2) } MAX-ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether fastboot is enabled or not on the switch." DEFVAL { disable } ::= { hpSwitchReboot 2 } hpSwitchProtectedPortsConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 26 } hpSwitchProtectedPortsMask OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This variable specifies a group of ports that are not allowed to communicate to each-other. Each octet within the value of this object specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the most significant bit represents the lowest numbered port, and the least significant bit represents the highest numbered port. Thus, each port of the switch is represented by a single bit within the value of this object." ::= { hpSwitchProtectedPortsConfig 1 } -- ********************************************************** -- Trap Definitions -- ********************************************************** hpSwitchTraps OBJECT IDENTIFIER ::= { hpSwitchConfig 0 } hpSwitchTrapsObjects OBJECT IDENTIFIER ::= { hpSwitchTraps 1 } hpSwitchStpErrantBpduDetector OBJECT-TYPE SYNTAX INTEGER { bpduFilter (1), bpduProtection (2), pvstFilter (3), pvstProtection (4) } ACCESS accessible-for-notify STATUS optional DESCRIPTION "The identifier of the feature generating Errant BPDU trap." ::= { hpSwitchTrapsObjects 1 } hpSwitchStpErrantBpduSrcMac OBJECT-TYPE SYNTAX MacAddress ACCESS accessible-for-notify STATUS optional DESCRIPTION "The source MAC address of the port sending Errant STP BPDU." ::= { hpSwitchTrapsObjects 2 } hpSwitchStpErrantBpduReceived TRAP-TYPE ENTERPRISE hpSwitchTraps VARIABLES { hpSwitchStpPort, hpSwitchStpPortErrantBpduCounter, dot1dStpPortState, dot1dStpPortDesignatedBridge, dot1dStpPortDesignatedPort, hpSwitchStpErrantBpduSrcMac, hpSwitchStpErrantBpduDetector } DESCRIPTION "This trap indicates that unexpected (errant) STP BPDU has been received on a port (e.g. on a port that is connected to non-STP device). This notification trap is controlled by the state of 'hpSwitchStpTrapCntl' object. Implementation of this trap is optional." ::= 1 END