HP-ICF-8023-RPTR DEFINITIONS ::= BEGIN IMPORTS Integer32, Counter32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI DisplayString, TruthValue FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF rptrPortAutoPartitionState FROM SNMP-REPEATER-MIB -- 802.3 Repeater MIB rpMauMediaAvailable, rpMauGroupIndex, rpMauPortIndex, rpMauIndex FROM MAU-MIB hpicfObjectModules, hpicfRepeater, hpicf8023RptrTrapsPrefix FROM HP-ICF-OID; hpicf8023RptrMib MODULE-IDENTITY LAST-UPDATED "200011032210Z" -- November 3, 2000 ORGANIZATION "Hewlett Packard Company, Network Infrastructure Solutions" CONTACT-INFO "Hewlett Packard Company 8000 Foothills Blvd. Roseville, CA 95747" DESCRIPTION "This MIB module contains objects that provide HP-specific extensions to the 802.3 Repeater MIB." REVISION "200011032210Z" -- November 3, 2000 DESCRIPTION "Updated division name." REVISION "9807162027Z" -- July 16, 1998 DESCRIPTION "Added repeater port auto-negotiation objects." REVISION "9609100219Z" -- September 10, 1996 DESCRIPTION "Split this MIB module from the former monolithic hp-icf MIB. Added hpicf8023MultiRptr groups. Deprecated objects that presumed a single repeater segment." REVISION "9402250000Z" -- February 25, 1994 DESCRIPTION "Initial revision of this MIB module. Released with the AdvanceStack 10BaseT hubs: HPJ2600A, HPJ2601A and HPJ2602A and agent module HPJ2603A." ::= { hpicfObjectModules 9 } hpRptrBasic OBJECT IDENTIFIER ::= { hpicfRepeater 1 } hpRptrBasicGlobal OBJECT IDENTIFIER ::= { hpRptrBasic 1 } hpRptrEntityName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* The local name of this repeater. This is the same value as hpicfEntityName in the case where there is Distributed Management Protocol to access this device. For SNMPv1, this name is appended to the agent community name to obtain a community name to use to specify that the agent should proxy to this repeater. For example, if this agent has a community with a community name of 'public', and the value of this object is 'repeater1', the community 'public/repeater1' will specify that the agent should proxy to the public community of the repeater1 box to obtain management information about this repeater. If an agent receives a management request where the localEntity is not specified, it will default to the local repeater on which this agent is executing. This object has been deprecated. Since it is a scalar, it does not scale to systems containing multiple repeater segments. In addition, it is only considered useful in systems supporting the Distributed Management Chain, which has also been deprecated." ::= { hpRptrBasicGlobal 1 } hpRptrThinlanFault OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* When set to 'true' this object causes the Fault Led to blink if the ThinLan Port is segmented. This object has been deprecated. It only makes sense in systems that support a single BNC port." ::= { hpRptrBasicGlobal 2 } hpRptrSqeEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* When 'true', this flag indicates that SQE has been detected for the last ten agent transmits and there is a high probability that the SQE switch on the transceiver attached to the AUI port is set to Enabled, when it should be Disabled. This object has been deprecated, since it presumes that the system will only have a single AUI port. It has been replaced by the hpRptrPtSqeEnabled object." ::= { hpRptrBasicGlobal 3 } hpRptrRobustHealing OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* When this flag is set to 'true', it enables robust port healing mode. The 802.3 specification states that a segmented port is healed by successfully transmitting or receiving a packet on the port. This mode disables port healing on successful packet reception and requires that a packet be successfully transmitted on a port in order for a segmented port to be healed." ::= { hpRptrBasicGlobal 4 } hpRptrBasicGroup OBJECT IDENTIFIER ::= { hpRptrBasic 2 } hpRptrBasicGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF HpRptrBasicGroupEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* HP specific extensions to the rptrGroupTable." ::= { hpRptrBasicGroup 1 } hpRptrBasicGroupEntry OBJECT-TYPE SYNTAX HpRptrBasicGroupEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* An entry in the table, containing HP extensions for a specific group." INDEX { hpRptrGrpGroupIndex } ::= { hpRptrBasicGroupTable 1 } HpRptrBasicGroupEntry ::= SEQUENCE { hpRptrGrpGroupIndex Integer32, hpRptrGrpPortsAdminStatus OCTET STRING, hpRptrGrpPortsSegStatus OCTET STRING, hpRptrGrpPortsMediaAvailable OCTET STRING, hpRptrGrpPortsLinkbeatEnabled OCTET STRING, hpRptrGrpPortsOperStatus OCTET STRING } hpRptrGrpGroupIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* The group within the repeater for which this entry contains information. This object has the same value as the corresponding instance of rptrGroupIndex." ::= { hpRptrBasicGroupEntry 1 } hpRptrGrpPortsAdminStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* The hpRptrGrpPortsAdminStatus is a bit map of the state of the rptrPortAdminStatus object for all of the ports in this group. The object has a one bit for each port for which the value of rptrPortAdminStatus is equal to 'enabled(1)' and a zero bit for each port for which the value of rptrPortAdminStatus is equal to 'disabled(2)'. The bits are placed into the OCTET STRING in the following order: octet 0 octet 1 octet 2 ... bits 7-0 bits 7-0 bits 7-0 ... ports 1-8 ports 9-16 ports 17-24 ... Values of unused bits in the last octet are undefined." ::= { hpRptrBasicGroupEntry 2 } hpRptrGrpPortsSegStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* The hpRptrGrpPortsSegStatus is a bit map of the state of the rptrPortAutoPartitionState of all of the ports in this group. The object has a one bit for each port for which the value of rptrPortAutoPartitionState is equal to 'notAutoPartitioned(1)' and a zero bit for each port for which the value of rptrPortAutoPartitionState is equal to 'autoPartitioned(2)'. The bits are placed into the OCTET STRING in the following order: octet 0 octet 1 octet 2 ... bits 7-0 bits 7-0 bits 7-0 ... ports 1-8 ports 9-16 ports 17-24 ... Values of unused bits in the last octet are undefined." ::= { hpRptrBasicGroupEntry 3 } hpRptrGrpPortsMediaAvailable OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* The hpRptrGrpPortsMediaAvailable is a bit map of the state of the rpMauMediaAvailable object for all of the ports in this group. The object has a one bit for each port for which the value of rpMauMediaAvailable is equal to 'available(3)' and a zero bit for each port for which the value of rpMauMediaAvailable is not equal to 'available(3)'. The bits are placed into the OCTET STRING in the following order: octet 0 octet 1 octet 2 ... bits 7-0 bits 7-0 bits 7-0 ... ports 1-8 ports 9-16 ports 17-24 ... Values of unused bits in the last octet are undefined." ::= { hpRptrBasicGroupEntry 4 } hpRptrGrpPortsLinkbeatEnabled OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* The hpRptrGrpPortsLinkbeatEnabled is a bit map of the state of the hpRptrPtLinkbeatEnable object for all of the ports in this group. The object has a one bit for each port for which the value of hpRptrPtLinkbeatEnable is equal to 'true(1)' and a zero bit for each port for which the value of hpRptrPtLinkbeatEnable is equal to 'false(2)'. The bits are placed into the OCTET STRING in the following order: octet 0 octet 1 octet 2 ... bits 7-0 bits 7-0 bits 7-0 ... ports 1-8 ports 9-16 ports 17-24 ... Values of unused bits in the last octet are undefined." ::= { hpRptrBasicGroupEntry 5 } hpRptrGrpPortsOperStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* The hpRptrGrpPortsOperStatus is a bit map of the state of all hub ports in the group. The object has a 1 bit for each port that is enabled, not segmented, and the media is available. Ports on which these conditions are not true have a 0 bit. The bits are placed into the OCTET STRING in the following order: octet 0 octet 1 octet 2 ... bits 7-0 bits 7-0 bits 7-0 ... ports 1-8 ports 9-16 ports 17-24 ... Values of unused bits in the last octet are undefined." ::= { hpRptrBasicGroupEntry 6 } hpRptrBasicPort OBJECT IDENTIFIER ::= { hpRptrBasic 3 } hpRptrBasicPtTable OBJECT-TYPE SYNTAX SEQUENCE OF HpRptrBasicPtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "HP specific extensions to the rptrPortTable." ::= { hpRptrBasicPort 1 } hpRptrBasicPtEntry OBJECT-TYPE SYNTAX HpRptrBasicPtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing HP extensions for a specific port." INDEX { hpRptrPtGroupIndex, hpRptrPtPortIndex } ::= { hpRptrBasicPtTable 1 } HpRptrBasicPtEntry ::= SEQUENCE { hpRptrPtGroupIndex Integer32, hpRptrPtPortIndex Integer32, hpRptrPtLinkbeatEnable TruthValue, hpRptrPtPolarityReversed TruthValue, hpRptrPtSqeEnabled TruthValue, hpRptrPtMediaAvailTrapEnable TruthValue, hpRptrPtLongCableEnable TruthValue } hpRptrPtGroupIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The group containing the port for which this entry contains information. This object has the same value as the corresponding instance of rptrPortGroupIndex." ::= { hpRptrBasicPtEntry 1 } hpRptrPtPortIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The port within the group for which this entry contains information. This object has the same value as the corresponding instance of rptrPortIndex." ::= { hpRptrBasicPtEntry 2 } hpRptrPtLinkbeatEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "When this flag is set to 'true' the port's link beat is enabled and when set to 'false' it is disabled." ::= { hpRptrBasicPtEntry 3 } hpRptrPtPolarityReversed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to indicate that the hub port was wired with the positive/negative polarity of its transmit and receive pairs reversed. Note that the port will continue to operate in this state, with the hub inverting the polarity internally." ::= { hpRptrBasicPtEntry 4 } hpRptrPtSqeEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "When 'true', this flag indicates that SQE has been detected for the last ten agent transmits and there is a high probability that the SQE switch on the transceiver attached to this port is set to Enabled, when it should be Disabled. This value can only be 'true' on AUI ports." ::= { hpRptrBasicPtEntry 5 } hpRptrPtMediaAvailTrapEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether hpicfMediaAvailDetectTrap and hpicfMediaAvailLostTrap events should be generated for MAUs attached to this port. This object has the value of 'false' by default. Setting the value of this object to 'true' will cause a hpicfMediaAvailDetectTrap event to be generated whenever an instance of rpMauMediaAvailable object associated with a MAU attached to this port enters the 'available' state, and a hpicfMediaAvailLostTrap to be generated whenever an instance of the rpMauMediaAvailable object associated with a MAU attached to this port exits the 'available' state. Note that the disposition of these events is controlled by the RMON eventTable. We recommend that this object is only be set to 'true' on important ports, such as cascade ports and ports attached to routers bridges, switches, or servers. Setting this object to 'true' on other ports may cause irrelevant traps. For example, it is unlikely that an administrator would want to receive a trap every time a user turns their PC off." ::= { hpRptrBasicPtEntry 6 } hpRptrPtLongCableEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "When this flag is set to 'true' the port's squelch level will be reduced to account for extended distance connections. When set to 'false', this port's squelch level will be normal. We recommend that this object only be set to 'true' for ports that are actually connected to long cables." ::= { hpRptrBasicPtEntry 7 } hpRptrMonitor OBJECT IDENTIFIER ::= { hpicfRepeater 2 } hpRptrMonitorGlobal OBJECT IDENTIFIER ::= { hpRptrMonitor 1 } -- Note: The hpRptrMonitorGlobal counters that are composed of -- other objects are provided to allow for event testing on -- global error conditions. -- -- Note: the hpRptrMonitorGlobal counters have been deprecated. -- Since they are scalars, they do not scale to systems -- containing multiple repeater segments. The standard repeater -- MIB is adding per-repeater counters for collisions, total -- frames, total octets and total errors. Keeping per-repeater -- totals of the other counters included here was felt to be -- overkill. Another factor is that it is quite expensive to -- maintain global counters in the presence of port mobility, so -- it made sense to limit the number of total counters to those -- that would be the most useful for network management. Note -- that most of the information in these counters is available -- through other MIBs, such as the RMON etherStats group. hpRptrMonCounters OBJECT IDENTIFIER ::= { hpRptrMonitorGlobal 1 } hpRptrMonGlobalFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* The total number of frames of valid frame length that have been received on all ports in this repeater. This counter is the summation of the values of the rptrMonitorPortReadableFrames counter for all of the ports in this repeater. Equivalently, this counter is the summation of the values of the rptrMonitorGroupTotalFrames counter for all of the port groups in this repeater." REFERENCE "RFC 1516 rptrMonitorPortReadableFrames and rptrMonitorGroupTotalFrames, and IEEE 802.3 Rptr Mgt, 19.2.6.2, aReadableFrames." ::= { hpRptrMonCounters 1 } hpRptrMonGlobalOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* The total number of octets contained in the valid frames that have been received on the ports in this repeater. This counter is the summation of the values of the rptrMonitorPortReadableOctets counter for all of the ports in this repeater. Equivalently, this counter is the summation of the values of the rptrMonitorGroupTotalOctets counter for all of the port groups in this repeater." REFERENCE "RFC 1516 rptrMonitorPortReadableOctets and rptrMonitorGroupTotalOctets, and IEEE 802.3 Rptr Mgt, 19.2.6.2, aReadableOctets." ::= { hpRptrMonCounters 2 } hpRptrMonGlobalFCSErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each frame received on any port with the FCSError signal asserted and the FramingError and CollisionEvent signals deasserted and whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std). This counter is the summation of the values of the rptrMonitorPortFCSErrors counter for all of the ports in this repeater." REFERENCE "RFC 1516 rptrMonitorPortFCSErrors and IEEE 802.3 Rptr Mgt, 19.2.6.2, aFrameCheckSequenceErrors." ::= { hpRptrMonCounters 3 } hpRptrMonGlobalAlignmentErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each frame received on any port with the FCSError and FramingError signals asserted and CollisonEvent signal deasserted and whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std). If hpRptrMonGlobalAlignmentErrors is incremented, then the hpRptrMonGlobalFCSErorrs counter shall not be incremented for the same frame. This counter is the summation of the values of the rptrMonitorPortAlignmentErrors counter for all of the ports in this repeater." REFERENCE "RFC 1516 rptrMonitorPortAlignmentErrors and IEEE 802.3 Rptr Mgt, 19.2.6.2, aAlignmentErrors." ::= { hpRptrMonCounters 4 } hpRptrMonGlobalFrameTooLongs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each frame received on any port whose OctetCount is greater than maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std). If hpRptrMonGlobalFrameTooLongs is incremented, then neither the hpRptrMonGlobalAlignmentErorrs nor the hpRptrMonGlobalFCSErrors counter shall be incremented for the frame. This counter is the summation of the values of the rptrMonitorPortFrameTooLongs counter for all of the ports in this repeater." REFERENCE "RFC 1516 rptrMonitorPortFrameTooLongs and IEEE 802.3 Rptr Mgt, 19.2.6.2, aFramesTooLong" ::= { hpRptrMonCounters 5 } hpRptrMonGlobalShortEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each CarrierEvent on any port with ActivityDuration less than ShortEventMaxTime. ShortEventMaxTime is greater than 74 bit times and less than 82 bit times. ShortEventMaxTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine. This counter is the summation of the values of the rptrMonitorPortShortEvents counter for all of the ports in this repeater." REFERENCE "RFC 1516 rptrMonitorPortShortEvents and IEEE 802.3 Rptr Mgt, 19.2.6.2, aShortEvents." ::= { hpRptrMonCounters 6 } hpRptrMonGlobalRunts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each CarrierEvent on any port that meets one of the following two conditions. Only one test need be made. a) The ActivityDuration is greater than ShortEventMaxTime and less than ValidPacketMinTime and the CollisionEvent signal is deasserted. b) The OctetCount is less than 64, the ActivityDuration is greater than ShortEventMaxTime and the CollisionEvent signal is deasserted. ValidPacketMinTime is greater than or equal to 552 bit times but less than 565 bit times. An event whose length is greater than 74 bit times but less than 82 bit times shall increment either the hpRptrMonGlobalShortEvents counter or the hpRptrMonGlobalRunts counter but not both. A CarrierEvent greater than or equal to 552 bit times but less than 565 bit times may or may not increment the hpRptrMonGlobalRunts counter. ValidPacketMinTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine. Runts usually indicate collision fragments, a normal network event. This counter is the summation of the values of the rptrMonitorPortRunts counter for all of the ports in this repeater." REFERENCE "RFC 1516 rptrMonitorPortRunts and IEEE 802.3 Rptr Mgt, 19.2.6.2, aRunts." ::= { hpRptrMonCounters 7 } hpRptrMonGlobalCollisions OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for any CarrierEvent signal on any port for which the CollisionEvent signal on any port is asserted. This counter differs from rptrMonitorTransmitCollisions in that it counts all collisions seen by this repeater, even those involving only a single port on this repeater, whereas rptrMonitorTransmitCollisions counts only collisions involving multiple ports on this repeater." REFERENCE "RFC 1516 rptrMonitorPortCollisions and IEEE 802.3 Rptr Mgt, 19.2.6.2, aCollisions." ::= { hpRptrMonCounters 8 } hpRptrMonGlobalLateEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each CarrierEvent on any port in which the CollIn(X) variable transitions to the value SQE (Ref: 9.6.6.2, IEEE 802.3 Std) while the ActivityDuration is greater than the LateEventThreshold. Such a CarrierEvent is counted twice, as both hpRptrMonGlobalCollisions and hpRptrMonGlobalLateEvents. The LateEventThreshold is greater than 480 bit times and less than 565 bit times. LateEventThreshold has tolerances included to permit an implementation to build a single threshold to serve as both the LateEventThreshold and ValidPacketMinTime threshold. This counter is the summation of the values of the rptrMonitorPortLateEvents counter for all of the ports in this repeater." REFERENCE "RFC 1516 rptrMonitorPortLateEvents and IEEE 802.3 Rptr Mgt, 19.2.6.2, aLateEvents." ::= { hpRptrMonCounters 9 } hpRptrMonGlobalVeryLongEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each CarrierEvent on any port whose ActivityDuration is greater than the MAU Jabber Lockup Protection timer TW3 (Ref: 9.6.1 & 9.6.5, IEEE 802.3 Std). Other counters may be incremented as appropriate. This counter is the summation of the values of the rptrMonitorPortVeryLongEvents counter for all of the ports in this repeater." REFERENCE "RFC 1516 rptrMonitorPortVeryLongEvents and IEEE 802.3 Rptr Mgt, 19.2.6.2, aVeryLongEvents." ::= { hpRptrMonCounters 10 } hpRptrMonGlobalDataRateMismatches OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each frame received on any port that meets all of the following conditions: a) The CollisionEvent signal is not asserted. b) The ActivityDuration is greater than ValidPacketMinTime. c) The frequency (data rate) is detectably mismatched from the local transmit frequency. The exact degree of mismatch is vendor specific and is to be defined by the vendor for conformance testing. When this event occurs, other counters whose increment conditions were satisfied may or may not also be incremented. This counter is the summation of the values of the rptrMonitorPortDatRateMismatches counter for all of the ports in this repeater." REFERENCE "RFC 1516 rptrMonitorPortDataRateMismatches and IEEE 802.3 Rptr Mgt, 19.2.6.2, aDataRateMismatches." ::= { hpRptrMonCounters 11 } hpRptrMonGlobalAutoPartitions OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each time the repeater has automatically partitioned any port. The conditions that cause port partitioning are specified in the partition state machine in Section 9 of the IEEE 802.3 Std. This counter is the summation of the values of the rptrMonitorPortAutoPartitions for all of the ports in this repeater." REFERENCE "RFC 1516 rptrMonitorPortAutoPartitions and IEEE 802.3 Rptr Mgt, 19.2.6.2, aAutoPartitions." ::= { hpRptrMonCounters 12 } hpRptrMonGlobalErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* The total number of errors which have occured on any port in this repeater. This counter is the summation of the values of other error counters, namely: hpRptrMonGlobalFCSErrors, hpRptrMonGlobalAlignmentErrors, hpRptrMonGlobalFrameTooLongs, hpRptrMonGlobalShortEvents, hpRptrMonGlobalLateEvents, hpRptrMonGlobalVeryLongEvents, and hpRptrMonGlobalDataRateMismatches. Equivalently, this counter is the summation of the values of the rptrMonitorPortTotalErrors counter for all of the ports in this repeater, or it is the summation of the values of rptrMonitorGroupTotalErrors for all of the port groups in this repeater." REFERENCE "RFC 1516, rptrMonitorGroupTotalErrors and hpRptrMonitorPortTotalErrors." ::= { hpRptrMonCounters 13 } hpRptrMonGlobalUcastPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each unicast packet of valid frame length received on any port. This counter is the summation of hpRptrMonPortUcastPackets for all of the ports in this repeater. This counter may not be implemented for repeaters which do not have a local network management agent." ::= { hpRptrMonCounters 14 } hpRptrMonGlobalBcastPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each broadcast packet of valid frame length received on any port. This counter is the summation of hpRptrMonPortBcastPackets for all of the ports in this repeater. This counter may not be implemented for repeaters which do not have a local network management agent." ::= { hpRptrMonCounters 15 } hpRptrMonGlobalMcastPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "********* THIS OBJECT IS DEPRECATED ********* This counter is incremented by one for each multicast packet of valid frame length received on any port. This counter is the summation of hpRptrMonPortMcastPackets for all of the ports in this repeater. This counter may not be implemented for repeaters which do not have a local network management agent." ::= { hpRptrMonCounters 16 } hpRptrMonitorGroup OBJECT IDENTIFIER ::= { hpRptrMonitor 2 } -- unused hpRptrMonitorPort OBJECT IDENTIFIER ::= { hpRptrMonitor 3 } hpRptrMonPtTable OBJECT-TYPE SYNTAX SEQUENCE OF HpRptrMonPtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of HP specific per port monitor objects." ::= { hpRptrMonitorPort 1 } hpRptrMonPtEntry OBJECT-TYPE SYNTAX HpRptrMonPtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing per port objects for a single port." INDEX { hpRptrMonPtGroupIndex, hpRptrMonPtPortIndex } ::= { hpRptrMonPtTable 1 } HpRptrMonPtEntry ::= SEQUENCE { hpRptrMonPtGroupIndex Integer32, hpRptrMonPtPortIndex Integer32, hpRptrMonPtUcastPackets Counter32, hpRptrMonPtBcastPackets Counter32, hpRptrMonPtMcastPackets Counter32 } hpRptrMonPtGroupIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The group containing the port for which this entry contains information. This object has the same value as the corresponding instance of rptrMonitorPortGroupIndex." ::= { hpRptrMonPtEntry 1 } hpRptrMonPtPortIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The port within the group for which this entry contains information. This object has the same value as the corresponding instance of rptrMonitorPortIndex." ::= { hpRptrMonPtEntry 2 } hpRptrMonPtUcastPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented by one for each unicast packet of valid frame length received on this port. This object may not be implemented for repeaters which do not have a local network management agent." ::= { hpRptrMonPtEntry 3 } hpRptrMonPtBcastPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented by one for each broadcast packet of valid frame length received on this port. This object may not be implemented for repeaters which do not have a local network management agent." ::= { hpRptrMonPtEntry 4 } hpRptrMonPtMcastPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented by one for each multicast packet of valid frame length received on this port. This object may not be implemented for repeaters which do not have a local network management agent." ::= { hpRptrMonPtEntry 5 } hpRpMauGroup OBJECT IDENTIFIER ::= { hpicfRepeater 4 } hpRpMauTable OBJECT-TYPE SYNTAX SEQUENCE OF HpRpMauEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "HP extensions to the rpMauTable." ::= { hpRpMauGroup 1 } hpRpMauEntry OBJECT-TYPE SYNTAX HpRpMauEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing HP extensions for a single MAU." INDEX { rpMauGroupIndex, rpMauPortIndex, rpMauIndex } ::= { hpRpMauTable 1 } HpRpMauEntry ::= SEQUENCE { hpRpMauTypeList BITS, hpRpMauAutoNegSupported TruthValue, hpRpMauAutoNegAdminStatus INTEGER, hpRpMauAutoNegRemoteSignaling INTEGER, hpRpMauAutoNegConfig INTEGER, hpRpMauAutoNegCapReceived BITS, hpRpMauAutoNegRestart INTEGER } hpRpMauTypeList OBJECT-TYPE SYNTAX BITS { bOther(0), -- other or unknown bAUI(1), -- AUI b10base5(2), -- 10BASE-5 bFoirl(3), -- FOIRL b10base2(4), -- 10BASE-2 b10baseT(5), -- 10BASE-T duplex mode unknown b10baseFP(6), -- 10BASE-FP b10baseFB(7), -- 10BASE-FB b10baseFL(8), -- 10BASE-FL duplex mode unknown b10broad36(9), -- 10BROAD36 b10baseTHD(10), -- 10BASE-T half duplex mode b10baseTFD(11), -- 10BASE-T full duplex mode b10baseFLHD(12), -- 10BASE-FL half duplex mode b10baseFLFD(13), -- 10BASE-FL full duplex mode b100baseT4(14), -- 100BASE-T4 b100baseTXHD(15), -- 100BASE-TX half duplex mode b100baseTXFD(16), -- 100BASE-TX full duplex mode b100baseFXHD(17), -- 100BASE-FX half duplex mode b100baseFXFD(18), -- 100BASE-FX full duplex mode b100baseT2HD(19), -- 100BASE-T2 half duplex mode b100baseT2FD(20) -- 100BASE-T2 full duplex mode } MAX-ACCESS read-only STATUS current DESCRIPTION "A value that uniquely identifies the set of possible IEEE 802.3 types that the MAU could be. If auto-negotiation is present on this MAU, this object will map to hpRpMauAutoNegCapability. Note that a repeater can never actually support the full-duplex MAU types. The bits for them are retained to keep the bit values consistent with ifMauTypeListBits." ::= { hpRpMauEntry 1 } hpRpMauAutoNegSupported OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates whether or not auto-negotiation is supported on this MAU." ::= { hpRpMauEntry 2 } hpRpMauAutoNegAdminStatus OBJECT-TYPE SYNTAX INTEGER { autoNegotiate(1), forceTo100TXHD(2), forceTo10THD(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to autoNegotiate(1) will cause auto-negotiation to be enabled on this port. Setting this object to forceTo100TXHD will cause auto-negotiation to be disabled on this port, and cause the operational type of the MAU on this port (as reported by rpMauType) to transition to dot3MauType100BaseTXHD. Setting this object to forceTo10THD will cause auto-negotiation to be disabled on this port, and cause the operational type of the MAU on this port (as reported by rpMauType) to transition to dot3MauType10BaseTHD." ::= { hpRpMauEntry 3 } hpRpMauAutoNegRemoteSignaling OBJECT-TYPE SYNTAX INTEGER { detected(1), notdetected(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "A value indicating whether the remote end of the link is using auto-negotiation signaling. It takes the value detected(1) if and only if, during the previous link negotiation, FLP Bursts were received." REFERENCE "[IEEE 802.3 Mgt], 30.6.1.1.3, aAutoNegRemoteSignaling." ::= { hpRpMauEntry 4 } hpRpMauAutoNegConfig OBJECT-TYPE SYNTAX INTEGER { other(1), configuring(2), complete(3), disabled(4), parallelDetectFail(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "A value indicating the current status of the auto-negotiation process. The enumeration parallelDetectFail(5) maps to a failure in parallel detection as defined in 28.2.3.1 of [IEEE 802.3 Std]." REFERENCE "[IEEE 802.3 Mgt], 30.6.1.1.4, aAutoNegAutoConfig." ::= { hpRpMauEntry 5 } hpRpMauAutoNegCapReceived OBJECT-TYPE SYNTAX BITS { bOther(0), -- other or unknown b10baseT(1), -- 10BASE-T half duplex mode b10baseTFD(2), -- 10BASE-T full duplex mode b100baseT4(3), -- 100BASE-T4 b100baseTX(4), -- 100BASE-TX half duplex mode b100baseTXFD(5), -- 100BASE-TX full duplex mode b100baseT2(6), -- 100BASE-T2 half duplex mode b100baseT2FD(7) -- 100BASE-T2 full duplex mode } MAX-ACCESS read-only STATUS current DESCRIPTION "A value that uniquely identifies the set of capabilities received from the remote auto-negotiation entity. Note that ports that support this MIB may be attached to remote auto-negotiation entities which have capabilities beyond the scope of this MIB." REFERENCE "[IEEE 802.3 Mgt], 30.6.1.1.7, aAutoNegReceivedTechnologyAbility." ::= { hpRpMauEntry 6 } hpRpMauAutoNegRestart OBJECT-TYPE SYNTAX INTEGER { restart(1), norestart(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "If the value of this object is set to restart(1) then this will force auto-negotiation to begin link renegotiation. If auto-negotiation signaling is disabled, a write to this object has no effect. Setting the value of this object to norestart(2) has no effect." REFERENCE "[IEEE 802.3 Mgt], 30.6.1.2.1, acAutoNegRestartAutoConfig." ::= { hpRpMauEntry 7 } -- 802.3 Repeater Specific Traps hpicfLinkBeatTrap NOTIFICATION-TYPE OBJECTS { rpMauMediaAvailable } STATUS deprecated DESCRIPTION "********* THIS NOTIFICATION IS DEPRECATED ********* A hpicfLinkBeatTrap is device type specific to ICF hubs. It signifies that the hub hardware has detected a change of state in a port's link beat status. The current value of the port's link beat status is returned in the PDU. This trap has been deprecated. It is replaced by the hpicfMediaAvailDetectTrap and the hpicfMediaAvailLostTrap." ::= { hpicf8023RptrTrapsPrefix 1 } hpicfPartitionTrap NOTIFICATION-TYPE OBJECTS { rptrPortAutoPartitionState } STATUS deprecated DESCRIPTION "********* THIS NOTIFICATION IS DEPRECATED ********* A hpicfPartitionTrap is device type specific to ICF hubs. It signifies that the hub hardware has detected a change of state in a port's partition status. The current value of the port's partition status is returned in the PDU. This trap has been deprecated. It is replaced by the hpicfPortPartitionTrap and the hpicfPortHealTrap." ::= { hpicf8023RptrTrapsPrefix 2 } hpicfMediaAvailDetectTrap NOTIFICATION-TYPE OBJECTS { rpMauMediaAvailable } STATUS current DESCRIPTION "A hpicfMediaAvailDetectTraps is device type specific to ICF hubs. It signifies that the hub hardware has detected an instance of rpMauMediaAvailable for one of the repeater's ports has entered the 'available' state from some other state. Note that this trap is only generated for instances of rpMauMediaAvailable associated with MAUs attached to repeater ports for which the corresponding instance of the hpRptrPtMediaAvailTrapEnable object is equal to 'true'. The previous value of the instance of the rpMauMediaAvailable object that entered the 'active' state is returned in the PDU." ::= { hpicf8023RptrTrapsPrefix 3 } hpicfMediaAvailLostTrap NOTIFICATION-TYPE OBJECTS { rpMauMediaAvailable } STATUS current DESCRIPTION "A hpicfMediaAvailLostTraps is device type specific to ICF hubs. It signifies that the hub hardware has detected an instance of rpMauMediaAvailable for one of the repeater's ports that had been in the 'available' state has exited that state. Note that this trap is only generated for instances of rpMauMediaAvailable associated with MAUs attached to repeater ports for which the corresponding instance of the hpRptrPtMediaAvailTrapEnable object is equal to 'true'. The new value of the instance of the rpMauMediaAvailable object that exited the 'active' state is returned in the PDU." ::= { hpicf8023RptrTrapsPrefix 4 } hpicfPortPartitionTrap NOTIFICATION-TYPE OBJECTS { rptrPortAutoPartitionState } STATUS current DESCRIPTION "A hpicfPortPartitionTrap is device type specific to ICF hubs. It signifies that the hub hardware has detected that an instance of rptrPortAutoPartitionState for one of the repeater's ports has changed from the 'notAutoPartitioned' state to the 'autoPartitioned' state. The current value of the instance of the rptrPortAutoPartitionState for the port that auto-partitioned is returned in the PDU." ::= { hpicf8023RptrTrapsPrefix 5 } hpicfPortHealTrap NOTIFICATION-TYPE OBJECTS { rptrPortAutoPartitionState } STATUS current DESCRIPTION "A hpicfPortHealTrap is device type specific to ICF hubs. It signifies that the hub hardware has detected that an instance of rptrPortAutoPartitionState for one of the repeater's ports has changed from the 'autoPartitioned' state to the 'notAutoPartitioned' state. The current value of the instance of the rptrPortAutoPartitionState for the port that healed is returned in the PDU." ::= { hpicf8023RptrTrapsPrefix 6 } -- Conformance information hpicf8023RptrConformance OBJECT IDENTIFIER ::= { hpicf8023RptrMib 1 } hpicf8023RptrCompliances OBJECT IDENTIFIER ::= { hpicf8023RptrConformance 1 } hpicf8023RptrGroups OBJECT IDENTIFIER ::= { hpicf8023RptrConformance 2 } -- Compliance statements hpicf8023RptrCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "********* THIS COMPLIANCE IS DEPRECATED ********* The compliance statement for HP extensions to the 802.3 Repeater MIB for HP AdvanceStack 802.3 repeaters." MODULE MANDATORY-GROUPS { hpicf8023RptrBasicGroup, hpicf8023RptrMonitorGroup, hpicf8023RptrNotifyGroup } ::= { hpicf8023RptrCompliances 1 } hpicf8023RptrSlaveCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "********* THIS COMPLIANCE IS DEPRECATED ********* The compliance statement for HP extensions to the 802.3 Repeater MIB for HP AdvanceStack 802.3 slave repeaters." MODULE MANDATORY-GROUPS { hpicf8023RptrBasicSlaveGroup, hpicf8023RptrMonitorSlaveGroup, hpicf8023RptrNotifyGroup } ::= { hpicf8023RptrCompliances 2 } hpicf8023MultiRptrCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for HP extensions to the 802.3 Repeater MIB for HP AdvanceStack 802.3 repeaters. This compliance supports devices with multiple repeater segments, as well as devices with a single repeater segment." MODULE MANDATORY-GROUPS { hpicf8023MultiRptrBasicGroup, hpicf8023MultiRptrMonitorGroup, hpicf8023MultiRptrNotifyGroup } ::= { hpicf8023RptrCompliances 3 } hpicf8023RptrAutoNegCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for HP extensions to the 802.3 Repeater MIB for HP AdvanceStack 802.3 repeaters. This compliance supports devices with multiple repeater segments, as well as devices with a single repeater segment. It also supports repeater devices with auto-negotiation." MODULE MANDATORY-GROUPS { hpicf8023MultiRptrBasicGroup, hpicf8023MultiRptrMonitorGroup, hpicf8023MultiRptrNotifyGroup } GROUP hpicf8023RpMauAutoNegGroup DESCRIPTION "Implementation of this group is required for MAUs that support auto-negotiation." ::= { hpicf8023RptrCompliances 4 } -- Units of conformance hpicf8023RptrBasicGroup OBJECT-GROUP OBJECTS { hpRptrEntityName, hpRptrThinlanFault, hpRptrSqeEnabled, hpRptrRobustHealing, hpRptrGrpGroupIndex, hpRptrGrpPortsAdminStatus, hpRptrGrpPortsSegStatus, hpRptrGrpPortsMediaAvailable, hpRptrGrpPortsLinkbeatEnabled, hpRptrGrpPortsOperStatus, hpRptrPtGroupIndex, hpRptrPtPortIndex, hpRptrPtLinkbeatEnable, hpRptrPtPolarityReversed } STATUS deprecated DESCRIPTION "********* THIS GROUP IS DEPRECATED ********* A collection of HP specific extensions to the 802.3 Repeater MIB for the HP AdvanceStack product line." ::= { hpicf8023RptrGroups 1 } hpicf8023RptrBasicSlaveGroup OBJECT-GROUP OBJECTS { hpRptrEntityName, hpRptrThinlanFault, hpRptrSqeEnabled, hpRptrGrpGroupIndex, hpRptrGrpPortsAdminStatus, hpRptrGrpPortsSegStatus, hpRptrGrpPortsMediaAvailable, hpRptrGrpPortsLinkbeatEnabled, hpRptrGrpPortsOperStatus, hpRptrPtGroupIndex, hpRptrPtPortIndex, hpRptrPtLinkbeatEnable, hpRptrPtPolarityReversed } STATUS deprecated DESCRIPTION "********* THIS GROUP IS DEPRECATED ********* A collection of HP specific extensions to the 802.3 Repeater MIB for HP AdvanceStack slaves." ::= { hpicf8023RptrGroups 2 } hpicf8023RptrMonitorGroup OBJECT-GROUP OBJECTS { hpRptrMonGlobalFrames, hpRptrMonGlobalOctets, hpRptrMonGlobalFCSErrors, hpRptrMonGlobalAlignmentErrors, hpRptrMonGlobalFrameTooLongs, hpRptrMonGlobalShortEvents, hpRptrMonGlobalRunts, hpRptrMonGlobalCollisions, hpRptrMonGlobalLateEvents, hpRptrMonGlobalVeryLongEvents, hpRptrMonGlobalDataRateMismatches, hpRptrMonGlobalAutoPartitions, hpRptrMonGlobalErrors, hpRptrMonGlobalUcastPackets, hpRptrMonGlobalBcastPackets, hpRptrMonGlobalMcastPackets, hpRptrMonPtGroupIndex, hpRptrMonPtPortIndex, hpRptrMonPtUcastPackets, hpRptrMonPtBcastPackets, hpRptrMonPtMcastPackets } STATUS deprecated DESCRIPTION "********* THIS GROUP IS DEPRECATED ********* A collection of extended counters for 802.3 repeaters in the HP AdvanceStack product line." ::= { hpicf8023RptrGroups 3 } hpicf8023RptrMonitorSlaveGroup OBJECT-GROUP OBJECTS { hpRptrMonGlobalFrames, hpRptrMonGlobalOctets, hpRptrMonGlobalFCSErrors, hpRptrMonGlobalAlignmentErrors, hpRptrMonGlobalFrameTooLongs, hpRptrMonGlobalShortEvents, hpRptrMonGlobalRunts, hpRptrMonGlobalCollisions, hpRptrMonGlobalLateEvents, hpRptrMonGlobalVeryLongEvents, hpRptrMonGlobalDataRateMismatches, hpRptrMonGlobalAutoPartitions, hpRptrMonGlobalErrors } STATUS deprecated DESCRIPTION "********* THIS GROUP IS DEPRECATED ********* A collection of extended counters for HP AdvanceStack 802.3 slave repeaters." ::= { hpicf8023RptrGroups 4 } hpicf8023MultiRptrBasicGroup OBJECT-GROUP OBJECTS { hpRptrPtGroupIndex, hpRptrPtPortIndex, hpRptrPtLinkbeatEnable, hpRptrPtPolarityReversed, hpRptrPtSqeEnabled, hpRptrPtMediaAvailTrapEnable, hpRptrPtLongCableEnable } STATUS current DESCRIPTION "A collection of HP specific extensions to the 802.3 Repeater MIB for products in the HP AdvanceStack product line. This group supports devices with multiple repeater segments as well as devices with a single repeater segment." ::= { hpicf8023RptrGroups 5 } hpicf8023MultiRptrMonitorGroup OBJECT-GROUP OBJECTS { hpRptrMonPtGroupIndex, hpRptrMonPtPortIndex, hpRptrMonPtUcastPackets, hpRptrMonPtBcastPackets, hpRptrMonPtMcastPackets } STATUS current DESCRIPTION "A collection of extended counters for 802.3 repeaters in the HP AdvanceStack product line. This group supports devices with multiple repeater segments as well as devices with a single repeater segment." ::= { hpicf8023RptrGroups 6 } hpicf8023RptrNotifyGroup NOTIFICATION-GROUP NOTIFICATIONS { hpicfLinkBeatTrap, hpicfPartitionTrap } STATUS deprecated DESCRIPTION "********* THIS GROUP IS DEPRECATED ********* A collection of notifications used to indicate changes in port status for 802.3 repeaters in the HP AdvanceStack product line." ::= { hpicf8023RptrGroups 7 } hpicf8023MultiRptrNotifyGroup NOTIFICATION-GROUP NOTIFICATIONS { hpicfMediaAvailDetectTrap, hpicfMediaAvailLostTrap, hpicfPortPartitionTrap, hpicfPortHealTrap } STATUS current DESCRIPTION "A collection of notifications used to indicate changes in port status for 802.3 repeaters in the HP AdvanceStack product line. Notifications in this group use different traps for good->bad than are used for bad->good (similar to linkUp/linkDown)." ::= { hpicf8023RptrGroups 8 } hpicf8023RpMauAutoNegGroup OBJECT-GROUP OBJECTS { hpRpMauTypeList, hpRpMauAutoNegSupported, hpRpMauAutoNegAdminStatus, hpRpMauAutoNegRemoteSignaling, hpRpMauAutoNegConfig, hpRpMauAutoNegCapReceived, hpRpMauAutoNegRestart } STATUS current DESCRIPTION "A collection of objects for managing MAUs attached to repeater ports with managed auto-negotiation." ::= { hpicf8023RptrGroups 9 } hpicf8023Rptr100BasicGroup OBJECT-GROUP OBJECTS { hpRptrPtGroupIndex, hpRptrPtPortIndex, hpRptrPtPolarityReversed, hpRptrPtMediaAvailTrapEnable } STATUS current DESCRIPTION "A collection of HP specific extensions to the 802.3 Repeater MIB for products in the HP AdvanceStack product line. This group supports devices with multiple repeater segments as well as devices with a single repeater segment. This group supports devices with 100BaseT repeater segments." ::= { hpicf8023RptrGroups 10 } END