HP-SN-SWITCH-GROUP-MIB DEFINITIONS ::= BEGIN -- Foundry SnSwitch Group MIB Release 2.0.0 -- Revision 0 08/18/96 -- Copyright 1996-97 Foundry Networks, Inc. -- All rights reserved. -- This Foundry Networks SNMP Management Information Base Specification -- (Specification) embodies Foundry Networks' confidential and -- proprietary intellectual property. Foundry Networks retains all -- title and ownership in the Specification, including any -- revisions. -- This Specification is supplied "AS IS," and Foundry Networks makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. -- SECTION 1: Top Level Definitions -- Imports IMPORTS Counter, TimeTicks, IpAddress, Gauge FROM RFC1155-SMI Unsigned32 FROM SNMPv2-SMI OBJECT-TYPE FROM RFC-1212 snSwitch FROM HP-SN-ROOT-MIB; -- textual conventions DisplayString ::= OCTET STRING -- This data type is used to model textual information taken -- from the NVT ASCII character set. By convention, objects -- with this syntax are declared as having -- -- SIZE (0..255) PhysAddress ::= OCTET STRING -- This data type is used to model media addresses. For many -- types of media, this will be in a binary representation. -- For example, an ethernet address would be represented as -- a string of 6 octets. MacAddress ::= OCTET STRING (SIZE(6)) -- This data type is used to model media addresses. For many -- types of media, this will be in a binary representation. -- For example, an ethernet address would be represented as -- a string of 6 octets. BridgeId ::= OCTET STRING (SIZE(8)) -- the Bridge-Identifier as used in the Spanning Tree Timeout ::= INTEGER -- a STP timer in units of 1/100 seconds PortMask ::= INTEGER -- This data type is used to model port bitmask. The -- maximum of ports are 32. InterfaceId ::= OBJECT IDENTIFIER -- This data type is used to specify an interface ID. -- The first object identifier is port type, and the -- format of the rest of the object identifiers depend -- on the port type. -- -- ethernet(1), format: type.slot.port -- e.g. 1.3.6 is port ethernet 3/6 -- -- pos(2), format: type.slot.port -- e.g. 2.10.1 is port pos 10/1 -- -- atm(3), format: type.slot.port -- e.g. 3.8.2 is port atm 8/2 -- -- virtual router interface(4), format: type.ve -- e.g. 4.9 is port ve 9 -- -- loopback(5), format: type.lb -- e.g. 5.7 is port loopback 7 -- -- gre tunnel(6), format: type.tn, not supported -- -- subinterface(7), format: type.slot.port.subInterface -- e.g. 7.3.2.4 is port atm 3/2.4 -- -- mpls tunnel(8), format: type.tn -- e.g. 8.3 is port tunnel 3 -- -- pvc(9), format: type.slot.port.subInterface.vpi.vci -- e.g. 9.3.1.2.1.2 is port atm 3/1.2.1.2 -- Groups snSwInfo OBJECT IDENTIFIER ::= { snSwitch 1 } snVLanInfo OBJECT IDENTIFIER ::= { snSwitch 2 } snSwPortInfo OBJECT IDENTIFIER ::= { snSwitch 3 } snFdbInfo OBJECT IDENTIFIER ::= { snSwitch 4 } snPortStpInfo OBJECT IDENTIFIER ::= { snSwitch 5 } snTrunkInfo OBJECT IDENTIFIER ::= { snSwitch 6 } snSwSummary OBJECT IDENTIFIER ::= { snSwitch 7 } snDhcpGatewayListInfo OBJECT IDENTIFIER ::= { snSwitch 8 } snDnsInfo OBJECT IDENTIFIER ::= { snSwitch 9 } snMacFilter OBJECT IDENTIFIER ::= { snSwitch 10 } snNTP OBJECT IDENTIFIER ::= { snSwitch 11 } snRadius OBJECT IDENTIFIER ::= { snSwitch 12 } snTacacs OBJECT IDENTIFIER ::= { snSwitch 13 } snQos OBJECT IDENTIFIER ::= { snSwitch 14 } snAAA OBJECT IDENTIFIER ::= { snSwitch 15 } snCAR OBJECT IDENTIFIER ::= { snSwitch 16 } snVLanCAR OBJECT IDENTIFIER ::= { snSwitch 17 } snNetFlow OBJECT IDENTIFIER ::= { snSwitch 18 } snSFlow OBJECT IDENTIFIER ::= { snSwitch 19 } snFDP OBJECT IDENTIFIER ::= { snSwitch 20 } snVsrp OBJECT IDENTIFIER ::= { snSwitch 21 } -- SECTION 2: Switch Group Configuration MIBs snSwGroupOperMode OBJECT-TYPE SYNTAX INTEGER { noVLan(1), vlanByPort(2) } ACCESS read-write STATUS mandatory DESCRIPTION "noVLan(1) represents all switch ports with no virtual LAN by port (no Port VLAN), and with no tag assigned. vlanByPort(2) represents all switch ports with Basic VLAN (layer2 Switch). " ::= { snSwInfo 1 } snSwGroupIpL3SwMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The Switch Group is configured with the Layer3 IP Switch mode either enabled or disabled and the default is disabled mode. enabled(1)...........activate Layer3 IP Switch disabled(0)..........disable Layer3 IP Switch" ::= { snSwInfo 2 } snSwGroupIpMcastMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The Switch Group is configured with the IP Multicast pruning mode either enabled or disabled and the default is disabled mode. enabled(1)...........activate IP Multicast pruning disabled(0)..........no IP Multicast pruning" ::= { snSwInfo 3 } snSwGroupDefaultCfgMode OBJECT-TYPE SYNTAX INTEGER { default(1), nonDefault(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The Switch Group is configured with the Default configuration. If the default configuration gets overwritten, the state will change to non-default. default(1)...........default configuration nonDefault(2)..........non default configuration" ::= { snSwInfo 4 } snSwGroupSwitchAgeTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Switch Age time is 180sec by default. The configured range is 10 to 10,000sec. The time represents the time span to age out an MAC Address entry." ::= { snSwInfo 5 } snVLanGroupVlanCurEntry OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current total entry number of VLANs are configured." ::= { snSwInfo 6 } snVLanGroupSetAllVLan OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the VLanIndex of a particalur entry in snVLanByPortTable (snVLanByPortVLanIndex). All the attributes of that row of table except PortMask will be used to set the same attributes for the entire VLan group. VLanId and PortMask must be set for that particular entry prior to setting this object. Switch software will base on that VLAN information to set the entire VLAN. Note: All the intended attributes of the given row of the table (given VLAN) must be set prior setting this object. When this object is set, Set-All-VLAN action will take place simultaneously. The previous setting will be overwritten by the new one." ::= { snSwInfo 7 } snSwPortSetAll OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the index number of the snSwPortInfoTable (snSwPortInfoPortIndex). snSwPortInfoMonitorMode, snSwPortInfoTagMode, snSwPortInfoChnMode, snSwPortInfoSpeed, snSwPortInfoAdminStatus are all the read-write attributes of that row of table. They will be used to set the same attributes for all the ports in the system. Note: prior setting this object, all the intended attributes of the given row of the table must be set. Otherwise, the current data of the row will be used to set the entire port-table. The previous setting will be overwritten by the new one." ::= { snSwInfo 8 } snFdbTableCurEntry OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current total entry number of FDB are configured." ::= { snSwInfo 9 } snFdbTableStationFlush OBJECT-TYPE SYNTAX INTEGER { normal(1), error(2), flush(3), flushing(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The following values of the flush state can only be read: normal(1)... normal state error(2)... operation failed flushing(4)... in process The following value can be written: flush(3).....do flush The agent will return a response even before the flush is done. And the read value will be flushing until flush is done. And the flush request will be rejected until error or normal." ::= { snSwInfo 10 } snPortStpSetAll OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is 1 which means invoking Port STP Set-all command. The snPortStpPriority, snPortStpPathCost, the read-write STP related attributes of the first row of table will be used to set the same attributes for all the ports in the system. Note: prior setting this object, all the intended attributes of the given row of the table must be set. Otherwise, the current data of the row will be used to set the entire port-table. The previous setting will be overwritten by the new one." ::= { snSwInfo 11 } snSwProbePortNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A chassis switch probe port is operated as a traffic analyzer port and only one port can be assigned in the chassis. The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number. A stackable switch is only assigned with one probe port as a traffic analyzer." ::= { snSwInfo 12 } snSw8021qTagMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The Switch Group is configured with the IEEE802.1q Tagging mode either enabled or disabled and the default is disabled mode. enabled(1)...........activate IEEE802.1q Tagging mode. disabled(0)..........no IEEE802.1q Tagging." ::= { snSwInfo 13 } snSwGlobalStpMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Spanning Tree System Global Mode in the Switch Group can be set either enabled or disabled and the default is enabled mode. enabled(1)...........activate Spanning Tree disabled(0)..........no Spanning Tree" ::= { snSwInfo 14 } snSwIpMcastQuerierMode OBJECT-TYPE SYNTAX INTEGER { querier(1), nonQuerier(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The IP Multicast pruning mode is configured either Non-Querier or Querier mode and the default is querier mode. querier(1)...........when prunning traffic locally within the VLAN. nonQuerier(2)........when running with a multicast capable router in the network." ::= { snSwInfo 15 } snSwViolatorPortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number of the switch or router that received a violator packet. It is included in the locked address violation trap. The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number (slot for chassis only)." ::= { snSwInfo 17 } snSwViolatorMacAddress OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "The source address of the violator packet received by the switch or router. It is included in the locked address violation trap." ::= { snSwInfo 18 } snVLanGroupVlanMaxEntry OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of VLAN entries are allowed to configure." ::= { snSwInfo 19 } snSwEosBufferSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A specific buffer size for all the different EOS buffers." ::= { snSwInfo 20 } snVLanByPortEntrySize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The size of each VLAN table entry." ::= { snSwInfo 21 } snSwPortEntrySize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The size of each port table entry." ::= { snSwInfo 22 } snFdbStationEntrySize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The size of each Fdb station table entry." ::= { snSwInfo 23 } snPortStpEntrySize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The size of each port stp table entry." ::= { snSwInfo 24 } snSwEnableBridgeNewRootTrap OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the SNMP agent process is permitted to generate bridge new root traps." DEFVAL { enabled } ::= { snSwInfo 25 } snSwEnableBridgeTopoChangeTrap OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the SNMP agent process is permitted to generate bridge topology change traps." DEFVAL { enabled } ::= { snSwInfo 26 } snSwEnableLockedAddrViolationTrap OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the SNMP agent process is permitted to generate locked address violation traps." DEFVAL { enabled } ::= { snSwInfo 27 } snSwIpxL3SwMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The Switch Group is configured with the Layer3 IPX Switch mode either enabled or disabled and the default is disabled mode. enabled(1)...........activate Layer3 Switch disabled(0)..........disable Layer3 Switch" ::= { snSwInfo 28 } snVLanByIpSubnetMaxSubnets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of subnets for each IP VLAN." ::= { snSwInfo 29 } snVLanByIpxNetMaxNetworks OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of networks for each IPX VLAN." ::= { snSwInfo 30 } snSwProtocolVLanMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "disabled(0) - represents system with Protocol VLAN disabled. enabled(1) - represents system with Protocol VLAN enabled (Layer3 VLAN)." ::= { snSwInfo 31 } snMacStationVLanId OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-write STATUS mandatory DESCRIPTION "This MAC Station VLAN ID index to the standard Forwarding Database for Transparent Bridge Table. (dot1dTpFdbTable). Since the dot1dTpFdbTable index is the MAC Address assigned to one of the ports in the bridge(VLAN) and each MAC address can be re-assigned to a different ports belonging to different bridges(VLANs), the snMacStationVLanId can be used by users to specify which bridge(VLAN) MAC Station information of the dot1dTpFdbTable users want to retrieve. If users do not specify the VLan ID in this MIB, the default VLAN (bridge) ID will be used when dot1dTpFdbTable is retrieved." ::= { snSwInfo 32 } snSwClearCounters OBJECT-TYPE SYNTAX INTEGER { valid(0), clear(1) } ACCESS read-write STATUS mandatory DESCRIPTION "valid(0) - a SNMP-GET of this mib shows that it is valid command to use. clear(1) - represents clear counter command of the following counters: Dot3, MIB2, IP and IPX counters for all ports." ::= { snSwInfo 33 } snSw8021qTagType OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The IEEE802.1q tag type embedded in the length/type field of an Ethernet packet. It specifies that the 2 octets after the length/type field in an Ethernet packet is the tag value." DEFVAL { 33024 } ::= { snSwInfo 34 } snSwBroadcastLimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Limit the number of broadcast packets to forward out of the switch ports. This object specifies the number of broadcast packets per second. Setting a value of 0 to this object disables the limitation check." DEFVAL { 0 } ::= { snSwInfo 35 } snSwMaxMacFilterPerSystem OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of MAC Filters per system in the MAC Filter table." ::= { snSwInfo 36 } snSwMaxMacFilterPerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of MAC Filters per port in the Port MAC Access Filter table." ::= { snSwInfo 37 } snSwDefaultVLanId OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-write STATUS mandatory DESCRIPTION "The VLAN ID of the DEFAULT PORT-VLAN." ::= { snSwInfo 38 } snSwGlobalAutoNegotiate OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1), negFullAuto(2), other(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This feature only applies to Gigabit Ethernet ports. If set to disable(0), all Gigabit Ethernet ports will be put to non- negotiation mode. If set to enable(1), all Gigabit Ethernet ports will start auto-negotiation indefinitely until succeed. If set to negFullAuto(2), all Gigabit Ethernet ports will start with auto-negotiation, if the negotiation failed, then they will automatically switch to non-negotiation mode. Stackable products (except TurboIron 8) Gigabit Ethernet ports do not support negFullAuto(2). If the snSwPortInfoAutoNegotiate value of a port was not set to global, this global value does not apply to the negotiation mode of that port." DEFVAL { negFullAuto } ::= { snSwInfo 39 } snSwQosMechanism OBJECT-TYPE SYNTAX INTEGER { strict(0), weighted(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the qos mechanism is strict or weighted." DEFVAL { weighted } ::= { snSwInfo 40 } snSwSingleStpMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Single Spanning Tree System Mode in the Switch Group can be set either enabled or disabled and the default is disabled mode. enabled(1)...........activate Single Spanning Tree disabled(0)..........no Single Spanning Tree" ::= { snSwInfo 41 } snSwFastStpMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Fast Spanning Tree System Mode in the Switch Group can be set either enabled or disabled and the default is enabled mode. enabled(1)...........activate Fast Spanning Tree disabled(0)..........no Fast Spanning Tree" ::= { snSwInfo 42 } -- VLAN Layer 2 Switch VLAN By Port Information Table snVLanByPortTable OBJECT-TYPE SYNTAX SEQUENCE OF SnVLanByPortEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "If snSwGroupOperMode is configured as basic mode which is VLAN by Port, Layer2 switching, then this table is valid. Each VLAN switch port could have a number of VLAN IDs." ::= { snVLanInfo 1 } snVLanByPortEntry OBJECT-TYPE SYNTAX SnVLanByPortEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "An entry in the VLAN By Port Information table. snVLanByPortVLanIndex = 1 and with snVLanByPortVLanId = 1 together implies all attributes applying to the Global switch group i.e. noVLan. A SNMP SET PDU for a row of the snVLanByPortTable requires the entired sequence of the MIB Objects in each snVLanByPortEntry stored in one PDU. Otherwise, GENERR return-value will be returned." INDEX { snVLanByPortVLanIndex } ::= { snVLanByPortTable 1 } SnVLanByPortEntry ::= SEQUENCE { snVLanByPortVLanIndex INTEGER, snVLanByPortVLanId INTEGER, snVLanByPortPortMask PortMask, snVLanByPortQos INTEGER, snVLanByPortStpMode INTEGER, snVLanByPortStpPriority INTEGER, snVLanByPortStpGroupMaxAge INTEGER, snVLanByPortStpGroupHelloTime INTEGER, snVLanByPortStpGroupForwardDelay INTEGER, snVLanByPortRowStatus INTEGER, snVLanByPortOperState INTEGER, snVLanByPortBaseNumPorts INTEGER, snVLanByPortBaseType INTEGER, snVLanByPortStpProtocolSpecification INTEGER, snVLanByPortStpMaxAge Timeout, snVLanByPortStpHelloTime Timeout, snVLanByPortStpHoldTime INTEGER, snVLanByPortStpForwardDelay Timeout, snVLanByPortStpTimeSinceTopologyChange TimeTicks, snVLanByPortStpTopChanges Counter, snVLanByPortStpRootCost INTEGER, snVLanByPortStpRootPort INTEGER, snVLanByPortStpDesignatedRoot BridgeId, snVLanByPortBaseBridgeAddress MacAddress, snVLanByPortVLanName DisplayString, snVLanByPortRouterIntf INTEGER, snVLanByPortChassisPortMask OCTET STRING, snVLanByPortPortList OCTET STRING } snVLanByPortVLanIndex OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS deprecated DESCRIPTION "The VLAN ID index must not be greater than the snVLanGroupVlanMaxEntry. Each VLAN Identifier can have a membership of multiple ports." ::= { snVLanByPortEntry 1 } snVLanByPortVLanId OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-write STATUS deprecated DESCRIPTION "The VLAN ID index to the VLAN By Port Info Table. Each VLAN Identifier can have a membership of multiple ports." ::= { snVLanByPortEntry 2 } snVLanByPortPortMask OBJECT-TYPE SYNTAX PortMask ACCESS read-write STATUS deprecated DESCRIPTION "The Standand-alone switch VLAN port membership. (It was obsoleted for Chassis Product)" ::= { snVLanByPortEntry 3 } snVLanByPortQos OBJECT-TYPE SYNTAX INTEGER { level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) } ACCESS read-write STATUS deprecated DESCRIPTION "The Stand alone stackable switch VLAN Priority values are: low(0) -- low prority high(1) -- high prority. The BigIron switch VLAN Priority values are: level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) " ::= { snVLanByPortEntry 4 } snVLanByPortStpMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS deprecated DESCRIPTION "Spanning Tree Mode in the Switch Group can be set either enabled or disabled and the default is enabled mode. enabled(1)...........activate Spanning Tree disabled(0)..........no Spanning Tree" ::= { snVLanByPortEntry 5 } snVLanByPortStpPriority OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS deprecated DESCRIPTION "dot1dStpPriority : The value of the write-able portion of the Stp ID, i.e., the first two octets of the (8 octet long) Bridge ID. The other (last) 6 octets of the Bridge ID are given by the value of the base bridge address - dot1dBaseBridgeAddress." ::= { snVLanByPortEntry 6 } snVLanByPortStpGroupMaxAge OBJECT-TYPE SYNTAX INTEGER (6..40) ACCESS read-write STATUS deprecated DESCRIPTION "dot1dStpBridgeMaxAge: From RFC1493(Bridge MIB). The value that all bridges use for MaxAge when this bridge is acting as the root. Note that 802.1D-1990 specifies that the range for this parameter is related to the value of dot1dStpBridgeHelloTime. The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds." ::= { snVLanByPortEntry 7 } snVLanByPortStpGroupHelloTime OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-write STATUS deprecated DESCRIPTION "dot1dStpBridgeHelloTime: From RFC1493(Bridge MIB). The value that all bridges use for HelloTime when this bridge is acting as the root. The granularity of this timer is specified by 802.1D- 1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds." ::= { snVLanByPortEntry 8 } snVLanByPortStpGroupForwardDelay OBJECT-TYPE SYNTAX INTEGER (2..30) ACCESS read-write STATUS deprecated DESCRIPTION "dot1dStpBridgeForwardDelay : From RFC1493(Bridge MIB). The value that all bridges use for ForwardDelay when this bridge is acting as the root. Note that 802.1D-1990 specifies that the range for this parameter is related to the value of dot1dStpBridgeMaxAge. The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds." ::= { snVLanByPortEntry 9 } snVLanByPortRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4), modify(5) } ACCESS read-write STATUS deprecated DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row modify(5)...modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid" ::= { snVLanByPortEntry 10 } snVLanByPortOperState OBJECT-TYPE SYNTAX INTEGER { notActivated(0), activated(1) } ACCESS read-only STATUS deprecated DESCRIPTION "By default, this mode is set to notActivated(0). notActivated(0)...the VLAN entry is not activated and not in running mode. activated(1)......the VLAN entry is activated and in running mode" ::= { snVLanByPortEntry 11 } snVLanByPortBaseNumPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "The number of ports controlled by this bridging entity." ::= { snVLanByPortEntry 12 } snVLanByPortBaseType OBJECT-TYPE SYNTAX INTEGER { unknown(1), transparent-only(2), sourceroute-only(3), srt(4) } ACCESS read-only STATUS deprecated DESCRIPTION "Indicates what type of bridging this bridge can perform. If a bridge is actually performing a certain type of bridging this will be indicated by entries in the port table for the given type." ::= { snVLanByPortEntry 13 } snVLanByPortStpProtocolSpecification OBJECT-TYPE SYNTAX INTEGER { unknown(1), decLb100(2), ieee8021d(3) } ACCESS read-only STATUS deprecated DESCRIPTION "An indication of what version of the Spanning Tree Protocol is being run. The value 'decLb100(2)' indicates the DEC LANbridge 100 Spanning Tree protocol. IEEE 802.1d implementations will return 'ieee8021d(3)'. If future versions of the IEEE Spanning Tree Protocol are released that are incompatible with the current version a new value will be defined." ::= { snVLanByPortEntry 14 } snVLanByPortStpMaxAge OBJECT-TYPE SYNTAX Timeout ACCESS read-only STATUS deprecated DESCRIPTION "dot1dStpMaxAge: From RFC1493(Bridge MIB). The maximum age of Spanning Tree Protocol information learned from the network on any port before it is discarded, in units of hundredths of a second. This is the actual value that this bridge is currently using." ::= { snVLanByPortEntry 15 } snVLanByPortStpHelloTime OBJECT-TYPE SYNTAX Timeout ACCESS read-only STATUS deprecated DESCRIPTION "dot1dStpHelloTime: From RFC1493(Bridge MIB). The amount of time between the transmission of Configuration bridge PDUs by this node on any port when it is the root of the spanning tree or trying to become so, in units of hundredths of a second. This is the actual value that this bridge is currently using." ::= { snVLanByPortEntry 16 } snVLanByPortStpHoldTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "dot1dStpHoldTime: From RFC1493(Bridge MIB). This time value determines the interval length during which no more than two Configuration bridge PDUs shall be transmitted by this node, in units of hundredths of a second." ::= { snVLanByPortEntry 17 } snVLanByPortStpForwardDelay OBJECT-TYPE SYNTAX Timeout ACCESS read-only STATUS deprecated DESCRIPTION "dot1dStpForwardDelay: From RFC1493(Bridge MIB). This time value, measured in units of hundredths of a second, controls how fast a port changes its spanning state when moving towards the Forwarding state. The value determines how long the port stays in each of the Listening and Learning states, which precede the Forwarding state. This value is also used, when a topology change has been detected and is underway, to age all dynamic entries in the Forwarding Database. [Note that this value is the one that this bridge is currently using, in contrast to dot1dStpBridgeForwardDelay which is the value that this bridge and all others would start using if/when this bridge were to become the root.]" ::= { snVLanByPortEntry 18 } snVLanByPortStpTimeSinceTopologyChange OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS deprecated DESCRIPTION "The time (in hundredths of a second) since the last time a topology change was detected by the bridge entity." ::= { snVLanByPortEntry 19 } snVLanByPortStpTopChanges OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS deprecated DESCRIPTION "The total number of topology changes detected by this bridge since the management entity was last reset or initialized." ::= { snVLanByPortEntry 20 } snVLanByPortStpRootCost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "dot1dStpRootCost: From RFC1493(Bridge MIB). The cost of the path to the root as seen from this bridge." ::= { snVLanByPortEntry 21 } snVLanByPortStpRootPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "dot1dStpRootPort: From RFC1493(Bridge MIB). The port number of the port which offers the lowest cost path from this bridge to the root bridge." ::= { snVLanByPortEntry 22 } snVLanByPortStpDesignatedRoot OBJECT-TYPE SYNTAX BridgeId ACCESS read-only STATUS deprecated DESCRIPTION "dot1dStpDesignatedRoot: From RFC1493(Bridge MIB). The bridge identifier of the root of the spanning tree as determined by the Spanning Tree Protocol as executed by this node. This value is used as the Root Identifier parameter in all Configuration Bridge PDUs originated by this node." ::= { snVLanByPortEntry 23 } snVLanByPortBaseBridgeAddress OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS deprecated DESCRIPTION "The MAC address used by this bridge when it must be referred to in a unique fashion. It is recommended that this be the numerically smallest MAC address of all ports that belong to this bridge. However it is only required to be unique. When concatenated with dot1dStpPriority a unique BridgeIdentifier is formed which is used in the Spanning Tree Protocol." ::= { snVLanByPortEntry 24 } snVLanByPortVLanName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS deprecated DESCRIPTION "VLAN Community Name string." ::= { snVLanByPortEntry 25 } snVLanByPortRouterIntf OBJECT-TYPE SYNTAX INTEGER (1..60) ACCESS read-write STATUS deprecated DESCRIPTION "Optional: A virtual interface for router to the VLAN -- applied to router only. If a SNMP-Get value is zero, that means this object was not configured." ::= { snVLanByPortEntry 26 } snVLanByPortChassisPortMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-write STATUS deprecated DESCRIPTION "The Chassis VLAN switch port membership. (It was obsoleted after release 07100, replaced by snVLanByPortPortList)" ::= { snVLanByPortEntry 27 } snVLanByPortPortList OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS deprecated DESCRIPTION "A list of port indices which are the port membership of a VLAN By Port. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number." ::= { snVLanByPortEntry 28 } -- Port VLAN (Layer 2 VLAN) Port Membership Table -- Use this table to create or delete a VLAN entry snVLanByPortMemberTable OBJECT-TYPE SYNTAX SEQUENCE OF SnVLanByPortMemberEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Port VLAN (Layer 2 VLAN) port membership table." ::= { snVLanInfo 6 } snVLanByPortMemberEntry OBJECT-TYPE SYNTAX SnVLanByPortMemberEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the port VLAN membership table." INDEX { snVLanByPortMemberVLanId, snVLanByPortMemberPortId } ::= { snVLanByPortMemberTable 1 } SnVLanByPortMemberEntry ::= SEQUENCE { snVLanByPortMemberVLanId INTEGER, snVLanByPortMemberPortId INTEGER, snVLanByPortMemberRowStatus INTEGER } snVLanByPortMemberVLanId OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The VLAN identifier (VLAN ID)." ::= { snVLanByPortMemberEntry 1 } snVLanByPortMemberPortId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex which is a member of the port VLAN." ::= { snVLanByPortMemberEntry 2 } snVLanByPortMemberRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid" ::= { snVLanByPortMemberEntry 3 } -- Port VLAN (Layer 2 VLAN) Configuration Table -- Use this table to configure a VLAN entry snVLanByPortCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF SnVLanByPortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Port VLAN (Layer 2 VLAN) configuration table." ::= { snVLanInfo 7 } snVLanByPortCfgEntry OBJECT-TYPE SYNTAX SnVLanByPortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the port VLAN configuration table." INDEX { snVLanByPortCfgVLanId } ::= { snVLanByPortCfgTable 1 } SnVLanByPortCfgEntry ::= SEQUENCE { snVLanByPortCfgVLanId INTEGER, snVLanByPortCfgQos INTEGER, snVLanByPortCfgStpMode INTEGER, snVLanByPortCfgStpPriority INTEGER, snVLanByPortCfgStpGroupMaxAge INTEGER, snVLanByPortCfgStpGroupHelloTime INTEGER, snVLanByPortCfgStpGroupForwardDelay INTEGER, snVLanByPortCfgBaseNumPorts INTEGER, snVLanByPortCfgBaseType INTEGER, snVLanByPortCfgStpProtocolSpecification INTEGER, snVLanByPortCfgStpMaxAge Timeout, snVLanByPortCfgStpHelloTime Timeout, snVLanByPortCfgStpHoldTime INTEGER, snVLanByPortCfgStpForwardDelay Timeout, snVLanByPortCfgStpTimeSinceTopologyChange TimeTicks, snVLanByPortCfgStpTopChanges Counter, snVLanByPortCfgStpRootCost INTEGER, snVLanByPortCfgStpRootPort INTEGER, snVLanByPortCfgStpDesignatedRoot BridgeId, snVLanByPortCfgBaseBridgeAddress MacAddress, snVLanByPortCfgVLanName DisplayString, snVLanByPortCfgRouterIntf INTEGER, snVLanByPortCfgRowStatus INTEGER } snVLanByPortCfgVLanId OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The VLAN identifier (VLAN ID)." ::= { snVLanByPortCfgEntry 1 } snVLanByPortCfgQos OBJECT-TYPE SYNTAX INTEGER { level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The Stand alone stackable switch VLAN Priority values are: level0(0) -- low prority level1(1) -- high prority. The BigIron switch VLAN Priority values are: level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) " ::= { snVLanByPortCfgEntry 2 } snVLanByPortCfgStpMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Spanning Tree Mode in the Switch Group can be set either enabled or disabled and the default is enabled mode. enabled(1)...........activate Spanning Tree disabled(0)..........no Spanning Tree" ::= { snVLanByPortCfgEntry 3 } snVLanByPortCfgStpPriority OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "dot1dStpPriority : The value of the write-able portion of the Stp ID, i.e., the first two octets of the (8 octet long) Bridge ID. The other (last) 6 octets of the Bridge ID are given by the value of the base bridge address - dot1dBaseBridgeAddress." ::= { snVLanByPortCfgEntry 4 } snVLanByPortCfgStpGroupMaxAge OBJECT-TYPE SYNTAX INTEGER (6..40) ACCESS read-write STATUS mandatory DESCRIPTION "dot1dStpBridgeMaxAge: From RFC1493(Bridge MIB). The value that all bridges use for MaxAge when this bridge is acting as the root. Note that 802.1D-1990 specifies that the range for this parameter is related to the value of dot1dStpBridgeHelloTime. The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds." ::= { snVLanByPortCfgEntry 5 } snVLanByPortCfgStpGroupHelloTime OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-write STATUS mandatory DESCRIPTION "dot1dStpBridgeHelloTime: From RFC1493(Bridge MIB). The value that all bridges use for HelloTime when this bridge is acting as the root. The granularity of this timer is specified by 802.1D- 1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds." ::= { snVLanByPortCfgEntry 6 } snVLanByPortCfgStpGroupForwardDelay OBJECT-TYPE SYNTAX INTEGER (2..30) ACCESS read-write STATUS mandatory DESCRIPTION "dot1dStpBridgeForwardDelay : From RFC1493(Bridge MIB). The value that all bridges use for ForwardDelay when this bridge is acting as the root. Note that 802.1D-1990 specifies that the range for this parameter is related to the value of dot1dStpBridgeMaxAge. The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds." ::= { snVLanByPortCfgEntry 7 } snVLanByPortCfgBaseNumPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of ports controlled by this bridging entity." ::= { snVLanByPortCfgEntry 8 } snVLanByPortCfgBaseType OBJECT-TYPE SYNTAX INTEGER { unknown(1), transparent-only(2), sourceroute-only(3), srt(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates what type of bridging this bridge can perform. If a bridge is actually performing a certain type of bridging this will be indicated by entries in the port table for the given type." ::= { snVLanByPortCfgEntry 9 } snVLanByPortCfgStpProtocolSpecification OBJECT-TYPE SYNTAX INTEGER { unknown(1), decLb100(2), ieee8021d(3) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication of what version of the Spanning Tree Protocol is being run. The value 'decLb100(2)' indicates the DEC LANbridge 100 Spanning Tree protocol. IEEE 802.1d implementations will return 'ieee8021d(3)'. If future versions of the IEEE Spanning Tree Protocol are released that are incompatible with the current version a new value will be defined." ::= { snVLanByPortCfgEntry 10 } snVLanByPortCfgStpMaxAge OBJECT-TYPE SYNTAX Timeout ACCESS read-only STATUS mandatory DESCRIPTION "dot1dStpMaxAge: From RFC1493(Bridge MIB). The maximum age of Spanning Tree Protocol information learned from the network on any port before it is discarded, in units of hundredths of a second. This is the actual value that this bridge is currently using." ::= { snVLanByPortCfgEntry 11 } snVLanByPortCfgStpHelloTime OBJECT-TYPE SYNTAX Timeout ACCESS read-only STATUS mandatory DESCRIPTION "dot1dStpHelloTime: From RFC1493(Bridge MIB). The amount of time between the transmission of Configuration bridge PDUs by this node on any port when it is the root of the spanning tree or trying to become so, in units of hundredths of a second. This is the actual value that this bridge is currently using." ::= { snVLanByPortCfgEntry 12 } snVLanByPortCfgStpHoldTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "dot1dStpHoldTime: From RFC1493(Bridge MIB). This time value determines the interval length during which no more than two Configuration bridge PDUs shall be transmitted by this node, in units of hundredths of a second." ::= { snVLanByPortCfgEntry 13 } snVLanByPortCfgStpForwardDelay OBJECT-TYPE SYNTAX Timeout ACCESS read-only STATUS mandatory DESCRIPTION "dot1dStpForwardDelay: From RFC1493(Bridge MIB). This time value, measured in units of hundredths of a second, controls how fast a port changes its spanning state when moving towards the Forwarding state. The value determines how long the port stays in each of the Listening and Learning states, which precede the Forwarding state. This value is also used, when a topology change has been detected and is underway, to age all dynamic entries in the Forwarding Database. [Note that this value is the one that this bridge is currently using, in contrast to dot1dStpBridgeForwardDelay which is the value that this bridge and all others would start using if/when this bridge were to become the root.]" ::= { snVLanByPortCfgEntry 14 } snVLanByPortCfgStpTimeSinceTopologyChange OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time (in hundredths of a second) since the last time a topology change was detected by the bridge entity." ::= { snVLanByPortCfgEntry 15 } snVLanByPortCfgStpTopChanges OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of topology changes detected by this bridge since the management entity was last reset or initialized." ::= { snVLanByPortCfgEntry 16 } snVLanByPortCfgStpRootCost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "dot1dStpRootCost: From RFC1493(Bridge MIB). The cost of the path to the root as seen from this bridge." ::= { snVLanByPortCfgEntry 17 } snVLanByPortCfgStpRootPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "dot1dStpRootPort: From RFC1493(Bridge MIB). The port number of the port which offers the lowest cost path from this bridge to the root bridge." ::= { snVLanByPortCfgEntry 18 } snVLanByPortCfgStpDesignatedRoot OBJECT-TYPE SYNTAX BridgeId ACCESS read-only STATUS mandatory DESCRIPTION "dot1dStpDesignatedRoot: From RFC1493(Bridge MIB). The bridge identifier of the root of the spanning tree as determined by the Spanning Tree Protocol as executed by this node. This value is used as the Root Identifier parameter in all Configuration Bridge PDUs originated by this node." ::= { snVLanByPortCfgEntry 19 } snVLanByPortCfgBaseBridgeAddress OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address used by this bridge when it must be referred to in a unique fashion. It is recommended that this be the numerically smallest MAC address of all ports that belong to this bridge. However it is only required to be unique. When concatenated with dot1dStpPriority a unique BridgeIdentifier is formed which is used in the Spanning Tree Protocol." ::= { snVLanByPortCfgEntry 20 } snVLanByPortCfgVLanName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "VLAN Community Name string." ::= { snVLanByPortCfgEntry 21 } snVLanByPortCfgRouterIntf OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Optional: A virtual interface for router to the VLAN -- applied to router only. If a SNMP-Get value is zero, that means this object was not configured." ::= { snVLanByPortCfgEntry 22 } snVLanByPortCfgRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Use object to delete a vlan entry." ::= { snVLanByPortCfgEntry 23 } -- VLAN by Protocol Configuration Table snVLanByProtocolTable OBJECT-TYPE SYNTAX SEQUENCE OF SnVLanByProtocolEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "." ::= { snVLanInfo 2 } snVLanByProtocolEntry OBJECT-TYPE SYNTAX SnVLanByProtocolEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the VLAN By Protocol Configuration table. " INDEX { snVLanByProtocolVLanId, snVLanByProtocolIndex } ::= { snVLanByProtocolTable 1 } SnVLanByProtocolEntry ::= SEQUENCE { snVLanByProtocolVLanId INTEGER, snVLanByProtocolIndex INTEGER, snVLanByProtocolDynamic INTEGER, snVLanByProtocolStaticMask PortMask, snVLanByProtocolExcludeMask PortMask, snVLanByProtocolRouterIntf INTEGER, snVLanByProtocolRowStatus INTEGER, snVLanByProtocolDynamicMask PortMask, snVLanByProtocolChassisStaticMask OCTET STRING, snVLanByProtocolChassisExcludeMask OCTET STRING, snVLanByProtocolChassisDynamicMask OCTET STRING, snVLanByProtocolVLanName DisplayString, snVLanByProtocolStaticPortList OCTET STRING, snVLanByProtocolExcludePortList OCTET STRING, snVLanByProtocolDynamicPortList OCTET STRING } snVLanByProtocolVLanId OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The VLAN ID index to both of the VLAN By Port Info Table and this table." ::= { snVLanByProtocolEntry 1 } snVLanByProtocolIndex OBJECT-TYPE SYNTAX INTEGER { ip(1), ipx(2), appleTalk(3), decNet(4), netBios(5), others(6), ipv6(7) } ACCESS read-only STATUS mandatory DESCRIPTION " The following IP/IPX protocol VLAN types are operated in Layer3 VLAN such as : ip(1), ipx(2), ipv6(7) The following are operated in Layer2 bridging such as: appleTalk(3), decNet(4), netBios(5), others(6) -- other protocols which are defined here. " ::= { snVLanByProtocolEntry 2 } snVLanByProtocolDynamic OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION " disabled(0) : disabled dynamic port inclusion - applied to switch only. enabled(1) : enabled dynamic port inclusion - applied to switch only. " ::= { snVLanByProtocolEntry 3 } snVLanByProtocolStaticMask OBJECT-TYPE SYNTAX PortMask ACCESS read-write STATUS deprecated DESCRIPTION "The Standand-alone switch Protocol VLAN port membership applied in static mode. (It was obsoleted for Chassis Product)" ::= { snVLanByProtocolEntry 4 } snVLanByProtocolExcludeMask OBJECT-TYPE SYNTAX PortMask ACCESS read-write STATUS deprecated DESCRIPTION "The Standand-alone switch Protocol VLAN port membership applied in exclusive mode. (It was obsoleted for Chassis Product)" ::= { snVLanByProtocolEntry 5 } snVLanByProtocolRouterIntf OBJECT-TYPE SYNTAX INTEGER (1..60) ACCESS read-write STATUS mandatory DESCRIPTION "Optional: A virtual interface for router to the VLAN -- applied to router only. If a SNMP-Get value is zero, that means this object was not configured." ::= { snVLanByProtocolEntry 6 } snVLanByProtocolRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4), modify(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row modify(5)...modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid" ::= { snVLanByProtocolEntry 7 } snVLanByProtocolDynamicMask OBJECT-TYPE SYNTAX PortMask ACCESS read-only STATUS deprecated DESCRIPTION "The Standand-alone switch Protocol VLAN active port membership. (It was obsoleted for Chassis Product)" ::= { snVLanByProtocolEntry 8 } snVLanByProtocolChassisStaticMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-write STATUS deprecated DESCRIPTION "The Chassis Protocol VLAN port membership applied in static mode. (It was obsoleted after release 07100, replaced by snVLanByProtocolStaticPortList)" ::= { snVLanByProtocolEntry 9 } snVLanByProtocolChassisExcludeMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-write STATUS deprecated DESCRIPTION "The Chassis Protocol VLAN port membership applied in exclusive mode. (It was obsoleted after release 07100, replaced by snVLanByProtocolExcludePortList)" ::= { snVLanByProtocolEntry 10 } snVLanByProtocolChassisDynamicMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-only STATUS deprecated DESCRIPTION "The Chassis Protocol VLAN active port membership. (It was obsoleted after release 07100, replaced by snVLanByProtocolDynamicPortList)" ::= { snVLanByProtocolEntry 11 } snVLanByProtocolVLanName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "VLAN Community Name string." ::= { snVLanByProtocolEntry 12 } snVLanByProtocolStaticPortList OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A list of port indices which are the configured port membership of the Protocol VLAN. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number." ::= { snVLanByProtocolEntry 13 } snVLanByProtocolExcludePortList OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A list of port indices which are the excluded from port membership of the Protocol VLAN. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number." ::= { snVLanByProtocolEntry 14 } snVLanByProtocolDynamicPortList OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A list of port indices which are dynamically joining the port membership of the Protocol VLAN. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number." ::= { snVLanByProtocolEntry 15 } -- VLAN By IP Subnet Configuration Table snVLanByIpSubnetTable OBJECT-TYPE SYNTAX SEQUENCE OF SnVLanByIpSubnetEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the VLAN By IPX Network Number Table." ::= { snVLanInfo 3 } snVLanByIpSubnetEntry OBJECT-TYPE SYNTAX SnVLanByIpSubnetEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the VLAN By IP Subnet Configuration table. " INDEX { snVLanByIpSubnetVLanId, snVLanByIpSubnetIpAddress, snVLanByIpSubnetSubnetMask } ::= { snVLanByIpSubnetTable 1 } SnVLanByIpSubnetEntry ::= SEQUENCE { snVLanByIpSubnetVLanId INTEGER, snVLanByIpSubnetIpAddress IpAddress, snVLanByIpSubnetSubnetMask IpAddress, snVLanByIpSubnetDynamic INTEGER, snVLanByIpSubnetStaticMask PortMask, snVLanByIpSubnetExcludeMask PortMask, snVLanByIpSubnetRouterIntf INTEGER, snVLanByIpSubnetRowStatus INTEGER, snVLanByIpSubnetDynamicMask PortMask, snVLanByIpSubnetChassisStaticMask OCTET STRING, snVLanByIpSubnetChassisExcludeMask OCTET STRING, snVLanByIpSubnetChassisDynamicMask OCTET STRING, snVLanByIpSubnetVLanName DisplayString, snVLanByIpSubnetStaticPortList OCTET STRING, snVLanByIpSubnetExcludePortList OCTET STRING, snVLanByIpSubnetDynamicPortList OCTET STRING } snVLanByIpSubnetVLanId OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The VLAN ID index to both of the VLAN By Port Info Table and this table." ::= { snVLanByIpSubnetEntry 1 } snVLanByIpSubnetIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Subnet IP address." ::= { snVLanByIpSubnetEntry 2 } snVLanByIpSubnetSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Subnet mask associated with the Subnet IP address." ::= { snVLanByIpSubnetEntry 3 } snVLanByIpSubnetDynamic OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION " disabled(0) : disabled dynamic port inclusion - applied to switch only. enabled(1) : enabled dynamic port inclusion - applied to switch only. " ::= { snVLanByIpSubnetEntry 4 } snVLanByIpSubnetStaticMask OBJECT-TYPE SYNTAX PortMask ACCESS read-write STATUS deprecated DESCRIPTION "The Standand-alone switch VLAN By Subnet port membership applied in static mode. (It was obsoleted for Chassis Product)" ::= { snVLanByIpSubnetEntry 5 } snVLanByIpSubnetExcludeMask OBJECT-TYPE SYNTAX PortMask ACCESS read-write STATUS deprecated DESCRIPTION "The Standand-alone switch VLAN By Subnet port membership applied in exclusive mode. (It was obsoleted for Chassis Product)" ::= { snVLanByIpSubnetEntry 6 } snVLanByIpSubnetRouterIntf OBJECT-TYPE SYNTAX INTEGER (1..60) ACCESS read-write STATUS mandatory DESCRIPTION "Optional: A virtual interface for router to the VLAN -- applied to router only. If a SNMP-Get value is zero, that means this object was not configured." ::= { snVLanByIpSubnetEntry 7 } snVLanByIpSubnetRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4), modify(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row modify(5)...modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid" ::= { snVLanByIpSubnetEntry 8 } snVLanByIpSubnetDynamicMask OBJECT-TYPE SYNTAX PortMask ACCESS read-only STATUS deprecated DESCRIPTION "The Standand-alone switch VLAN By Subnet active port membership. (It was obsoleted for Chassis Product)" ::= { snVLanByIpSubnetEntry 9 } snVLanByIpSubnetChassisStaticMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-write STATUS deprecated DESCRIPTION "The Chassis VLAN By Subnet port membership applied in static mode. (It was obsoleted after release 07100, replaced by snVLanByIpSubnetStaticPortList)" ::= { snVLanByIpSubnetEntry 10 } snVLanByIpSubnetChassisExcludeMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-write STATUS deprecated DESCRIPTION "The Chassis VLAN By Subnet port membership applied in exclusive mode. (It was obsoleted after release 07100, replaced by snVLanByIpSubnetExcludePortList)" ::= { snVLanByIpSubnetEntry 11 } snVLanByIpSubnetChassisDynamicMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-only STATUS deprecated DESCRIPTION "The Chassis VLAN By Subnet active port membership. (It was obsoleted after release 07100, replaced by snVLanByIpSubnetDynamicPortList)" ::= { snVLanByIpSubnetEntry 12 } snVLanByIpSubnetVLanName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "VLAN Community Name string." ::= { snVLanByIpSubnetEntry 13 } snVLanByIpSubnetStaticPortList OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A list of port indices which are the configured port membership of the VLAN By IP Subnet. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number." ::= { snVLanByIpSubnetEntry 14 } snVLanByIpSubnetExcludePortList OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A list of port indices which are the excluded from port membership of the VLAN By IP Subnet. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number." ::= { snVLanByIpSubnetEntry 15 } snVLanByIpSubnetDynamicPortList OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A list of port indices which are dynamically joining the port membership of the VLAN By IP Subnet. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number." ::= { snVLanByIpSubnetEntry 16 } -- VLAN By IPX Net Configuration Table snVLanByIpxNetTable OBJECT-TYPE SYNTAX SEQUENCE OF SnVLanByIpxNetEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the VLAN By IPX Network Number Table." ::= { snVLanInfo 4 } snVLanByIpxNetEntry OBJECT-TYPE SYNTAX SnVLanByIpxNetEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the VLAN By Ipx Network Number Configuration table. " INDEX { snVLanByIpxNetVLanId, snVLanByIpxNetNetworkNum, snVLanByIpxNetFrameType } ::= { snVLanByIpxNetTable 1 } SnVLanByIpxNetEntry ::= SEQUENCE { snVLanByIpxNetVLanId INTEGER, snVLanByIpxNetNetworkNum OCTET STRING, snVLanByIpxNetFrameType INTEGER, snVLanByIpxNetDynamic INTEGER, snVLanByIpxNetStaticMask PortMask, snVLanByIpxNetExcludeMask PortMask, snVLanByIpxNetRouterIntf INTEGER, snVLanByIpxNetRowStatus INTEGER, snVLanByIpxNetDynamicMask PortMask, snVLanByIpxNetChassisStaticMask OCTET STRING, snVLanByIpxNetChassisExcludeMask OCTET STRING, snVLanByIpxNetChassisDynamicMask OCTET STRING, snVLanByIpxNetVLanName DisplayString, snVLanByIpxNetStaticPortList OCTET STRING, snVLanByIpxNetExcludePortList OCTET STRING, snVLanByIpxNetDynamicPortList OCTET STRING } snVLanByIpxNetVLanId OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The VLAN ID index to both of the VLAN By Port Info Table and this table." ::= { snVLanByIpxNetEntry 1 } snVLanByIpxNetNetworkNum OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "IPX Network Number." ::= { snVLanByIpxNetEntry 2 } snVLanByIpxNetFrameType OBJECT-TYPE SYNTAX INTEGER { notApplicable(0), ipxEthernet8022(1), ipxEthernet8023(2), ipxEthernetII(3), ipxEthernetSnap(4) } ACCESS read-only STATUS mandatory DESCRIPTION " The following IPX Frame types are operated in Layer3 VLAN such as : ipxEthernet8022(1), ipxEthernet8023(2), ipxEthernetII(3), ipxEthernetSnap(4). choose notApplicable(0) for other protocols. Note: Each Network Number can be assigned with one unique Frame type; Otherwise, a SNMP-SET error will be returned." ::= { snVLanByIpxNetEntry 3 } snVLanByIpxNetDynamic OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION " disabled(0) : disabled dynamic port inclusion - applied to switch only. enabled(1) : enabled dynamic port inclusion - applied to switch only. " ::= { snVLanByIpxNetEntry 4 } snVLanByIpxNetStaticMask OBJECT-TYPE SYNTAX PortMask ACCESS read-write STATUS deprecated DESCRIPTION "The VLAN By IPX network port membership applied in static mode. (It was obsoleted for Chassis Product)" ::= { snVLanByIpxNetEntry 5 } snVLanByIpxNetExcludeMask OBJECT-TYPE SYNTAX PortMask ACCESS read-write STATUS deprecated DESCRIPTION "The VLAN By IPX network port membership applied in exclusive mode. (It was obsoleted for Chassis Product)" ::= { snVLanByIpxNetEntry 6 } snVLanByIpxNetRouterIntf OBJECT-TYPE SYNTAX INTEGER (1..60) ACCESS read-write STATUS mandatory DESCRIPTION "Optional: A virtual interface for router to the VLAN -- applied to router only. If a SNMP-Get value is zero, that means this object was not configured." ::= { snVLanByIpxNetEntry 7 } snVLanByIpxNetRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4), modify(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row modify(5)...modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid" ::= { snVLanByIpxNetEntry 8 } snVLanByIpxNetDynamicMask OBJECT-TYPE SYNTAX PortMask ACCESS read-only STATUS deprecated DESCRIPTION "The VLAN By IPX network active port membership. (It was obsoleted for Chassis Product)" ::= { snVLanByIpxNetEntry 9 } snVLanByIpxNetChassisStaticMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-write STATUS deprecated DESCRIPTION "The Chassis VLAN By IPX network port membership applied in static mode. (It was obsoleted after release 07100, replaced by snVLanByIpxNetStaticPortList)" ::= { snVLanByIpxNetEntry 10 } snVLanByIpxNetChassisExcludeMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-write STATUS deprecated DESCRIPTION "The Chassis VLAN By IPX network port membership applied in exclusive mode. (It was obsoleted after release 07100, replaced by snVLanByIpxNetExcludePortList)" ::= { snVLanByIpxNetEntry 11 } snVLanByIpxNetChassisDynamicMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-only STATUS deprecated DESCRIPTION "The Chassis VLAN By IPX network active port membership. (It was obsoleted after release 07100, replaced by snVLanByIpxNetDynamicPortList)" ::= { snVLanByIpxNetEntry 12 } snVLanByIpxNetVLanName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "VLAN Community Name string." ::= { snVLanByIpxNetEntry 13 } snVLanByIpxNetStaticPortList OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A list of port indices which are the configured port membership of the VLAN By IPX network. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number." ::= { snVLanByIpxNetEntry 14 } snVLanByIpxNetExcludePortList OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A list of port indices which are the excluded from port membership of the VLAN By IPX network. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number." ::= { snVLanByIpxNetEntry 15 } snVLanByIpxNetDynamicPortList OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A list of port indices which are dynamically joining the port membership of the VLAN By IPX network. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number." ::= { snVLanByIpxNetEntry 16 } -- VLAN By AppleTalk Cable Configuration Table snVLanByATCableTable OBJECT-TYPE SYNTAX SEQUENCE OF SnVLanByATCableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A Table Of VLAN By AppleTalk Network Number." ::= { snVLanInfo 5 } snVLanByATCableEntry OBJECT-TYPE SYNTAX SnVLanByATCableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the AppleTalk Cable VLAN table." INDEX {snVLanByATCableVLanId, snVLanByATCableIndex} ::= { snVLanByATCableTable 1 } SnVLanByATCableEntry ::= SEQUENCE { snVLanByATCableVLanId INTEGER, snVLanByATCableIndex INTEGER, snVLanByATCableRouterIntf INTEGER, snVLanByATCableRowStatus INTEGER, snVLanByATCableChassisStaticMask OCTET STRING, snVLanByATCableVLanName DisplayString, snVLanByATCableStaticPortList OCTET STRING } snVLanByATCableVLanId OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The VLAN ID of a PORT VLAN of which the AppleTalk Cable VLAN was attaching to." ::= { snVLanByATCableEntry 1 } snVLanByATCableIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "AppleTalk Cable VLAN index number." ::= { snVLanByATCableEntry 2 } snVLanByATCableRouterIntf OBJECT-TYPE SYNTAX INTEGER (0..60) ACCESS read-write STATUS mandatory DESCRIPTION "A virtual router interface to the AppleTalk Cable VLAN, only router products accept the SNMP-SET operation. The value zero indicates that virtual router interface was not configured." ::= { snVLanByATCableEntry 3 } snVLanByATCableRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4), modify(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row modify(5)...modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid" ::= { snVLanByATCableEntry 4 } snVLanByATCableChassisStaticMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-write STATUS deprecated DESCRIPTION "A list of ports which are statically configured to become port members of a VLAN. (It was obsoleted after release 07100, replaced by snVLanByATCableStaticPortList)" ::= { snVLanByATCableEntry 5 } snVLanByATCableVLanName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "VLAN Name string." ::= { snVLanByATCableEntry 6 } snVLanByATCableStaticPortList OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A list of port indices which are the configured port membership of the AppleTalk Cable VLAN. Each port index is a 16-bit integer in big endian order. 8-bit is the slot number, the other 8-bit is the port number." ::= { snVLanByATCableEntry 7 } -- Switch Port Information Group snSwPortInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF SnSwPortInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A specific snSwPortInfo group consists of a number of switch ports. " ::= { snSwPortInfo 1 } snSwPortInfoEntry OBJECT-TYPE SYNTAX SnSwPortInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the snSwPortInfo table indicates the configuration on a specified port. A SNMP SET PDU for a row of the snSwPortInfoTable requires the entired sequence of the MIB Objects in each snSwPortInfoEntry stored in one PDU. Otherwise, GENERR return-value will be returned." INDEX { snSwPortInfoPortNum } ::= { snSwPortInfoTable 1 } SnSwPortInfoEntry ::= SEQUENCE { snSwPortInfoPortNum INTEGER, snSwPortInfoMonitorMode INTEGER, snSwPortInfoTagMode INTEGER, snSwPortInfoChnMode INTEGER, snSwPortInfoSpeed INTEGER, snSwPortInfoMediaType INTEGER, snSwPortInfoConnectorType INTEGER, snSwPortInfoAdminStatus INTEGER, snSwPortInfoLinkStatus INTEGER, snSwPortInfoPortQos INTEGER, snSwPortInfoPhysAddress PhysAddress, snSwPortStatsInFrames Counter, snSwPortStatsOutFrames Counter, snSwPortStatsAlignErrors Counter, snSwPortStatsFCSErrors Counter, snSwPortStatsMultiColliFrames Counter, snSwPortStatsFrameTooLongs Counter, snSwPortStatsTxColliFrames Counter, snSwPortStatsRxColliFrames Counter, snSwPortStatsFrameTooShorts Counter, snSwPortLockAddressCount INTEGER, snSwPortStpPortEnable INTEGER, snSwPortDhcpGateListId INTEGER, snSwPortName DisplayString, snSwPortStatsInBcastFrames Counter, snSwPortStatsOutBcastFrames Counter, snSwPortStatsInMcastFrames Counter, snSwPortStatsOutMcastFrames Counter, snSwPortStatsInDiscard Counter, snSwPortStatsOutDiscard Counter, snSwPortStatsMacStations INTEGER, snSwPortCacheGroupId INTEGER, snSwPortTransGroupId INTEGER, snSwPortInfoAutoNegotiate INTEGER, snSwPortInfoFlowControl INTEGER, snSwPortInfoGigType INTEGER, snSwPortStatsLinkChange Counter, snSwPortIfIndex INTEGER, snSwPortDescr DisplayString, snSwPortInOctets OCTET STRING, snSwPortOutOctets OCTET STRING, snSwPortStatsInBitsPerSec Gauge, snSwPortStatsOutBitsPerSec Gauge, snSwPortStatsInPktsPerSec Gauge, snSwPortStatsOutPktsPerSec Gauge, snSwPortStatsInUtilization INTEGER (0..10000), snSwPortStatsOutUtilization INTEGER (0..10000), snSwPortFastSpanPortEnable INTEGER, snSwPortFastSpanUplinkEnable INTEGER, snSwPortVlanId INTEGER, snSwPortRouteOnly INTEGER, snSwPortPresent INTEGER, snSwPortGBICStatus INTEGER, snSwPortStatsInKiloBitsPerSec Unsigned32, snSwPortStatsOutKiloBitsPerSec Unsigned32, snSwPortLoadInterval INTEGER (30..300), snSwPortTagType INTEGER } snSwPortInfoPortNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port index. The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number (slot for chassis only)." ::= { snSwPortInfoEntry 1 } snSwPortInfoMonitorMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), input(1), output(2), both(3) } ACCESS read-write STATUS mandatory DESCRIPTION "A monitoring port is selected and its traffic will be analyzed if the mode is not disabled(0), which is the default mode. The values are: disabled(0) -- No traffic monitoring input(1) -- traffic monitoring is activated on packets received output(2) -- traffic monitoring is activated on packets transmitted both(3) -- traffic monitoring is activated on packets received and transmitted." ::= { snSwPortInfoEntry 2 } snSwPortInfoTagMode OBJECT-TYPE SYNTAX INTEGER { tagged(1), untagged(2), auto(3), disabled(4) } ACCESS read-write STATUS mandatory DESCRIPTION "For tagged port, we could have multiple VLANs per port. For untagged port or auto port, there is only one VLAN ID per port." ::= { snSwPortInfoEntry 3 } snSwPortInfoChnMode OBJECT-TYPE SYNTAX INTEGER { none(0), halfDuplex(1), fullDuplex(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The port can be configured to operate in either half or full duplex mode. The values are: halfDuplex(1)...half duplex mode fullDuplex(2)...full duplex mode The read-back channel status from hardware are: none(0).........link down or port disabled. halfDuplex(1)...half duplex mode fullDuplex(2)...full duplex mode The port media type (expansion or regular) and port link type (trunk or feeder) determine value of this object. The port can not set to half duplex mode if the port connect mode is m200e(4). However, the value of this parameter may be automatically set whenever the expansion port is connected (e.g. cascade connecting device)." ::= { snSwPortInfoEntry 4 } snSwPortInfoSpeed OBJECT-TYPE SYNTAX INTEGER { none(0), sAutoSense(1), s10M(2), s100M(3), s1G(4), s45M(5), s155M(6), s10G(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The speed configuration for a port. The values are: none(0)..........link down or no traffic. sAutoSense(1)....Auto-sensing 10 or 100Mbits. s10M(2)..........10Mbits per second. s100M(3).........100Mbits per second. s1G(4)...........1Gbits per second. s45M(5)..........45Mbits per second (T3) (for expansion board only). s155M(6).........155Mbits per second (ATM) (for expansion board only). s10G(7)..........10Gbits per second. The read-back hardware status are the following: none(0)..........link down or no traffic. s10M(2)..........10Mbits per second. s100M(3).........100Mbits per second. s1G(4)...........1Gbits per second. s45M(5)..........45Mbits per second (T3) (for expansion board only). s155M(6).........155Mbits per second (ATM) (for expansion board only). s10G(7)..........10Gbits per second. The port media type (expansion or regular) and port link type (trunk or feeder) determine whether this object can be written and the valid values. It is not allowed to change speed for trunks ports. For expansion ports, all of the above speed can be set. However, the value of this parameter may be automatically set whenever the expansion port is connected (e.g. cascade connecting device)." ::= { snSwPortInfoEntry 5 } snSwPortInfoMediaType OBJECT-TYPE SYNTAX INTEGER { other(1), m100BaseTX(2), m100BaseFX(3), m1000BaseFX(4), mT3(5), m155ATM(6), m1000BaseTX(7), m622ATM(8), m155POS(9), m622POS(10), m2488POS(11), m10000BaseFX(12) } ACCESS read-only STATUS mandatory DESCRIPTION "The media type for the port. The values are: other(1).........other or unknown media. m100BaseTX(2)....100Mbits per second copper. m100BaseFX(3)....100Mbits per second fiber. m1000BaseFX(4)...1Gbits per second fiber. mT3(5)...........45Mbits per second (T3). m155ATM(6).......155Mbits per second (ATM). m1000BaseTX(7)...1Gbits per second copper. m622ATM(8).......622Mbits per second (ATM). m155POS(9).......155Mbits per second (POS). m622POS(10)......622Mbits per second (POS). m2488POS(11).....2488Mbits per second (POS). m10000BaseFX(12).10Gbits per second fiber." ::= { snSwPortInfoEntry 6 } snSwPortInfoConnectorType OBJECT-TYPE SYNTAX INTEGER { other(1), copper(2), fiber(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of connector that the port offers. The values are: other(1)...........other or unknown connector copper(2)..........Copper connector fiber(3)...........Fiber connector This describes the physical connector type" ::= { snSwPortInfoEntry 7 } snSwPortInfoAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), -- ready to pass packets down(2), testing(3) -- in some test mode } ACCESS read-write STATUS mandatory DESCRIPTION "The desired state of all ports. The testing(3) state indicates that no operational packets can be passed. (same as ifAdminStatus in MIB-II)" ::= { snSwPortInfoEntry 8 } snSwPortInfoLinkStatus OBJECT-TYPE SYNTAX INTEGER { up(1), -- ready to pass packets down(2), testing(3) -- in some test mode } ACCESS read-only STATUS mandatory DESCRIPTION "The current operational state of the interface. The testing(3) state indicates that no operational packets can be passed. (same as ifOperStatus in MIB-II)" ::= { snSwPortInfoEntry 9 } snSwPortInfoPortQos OBJECT-TYPE SYNTAX INTEGER { level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The Stand alone stackable switch Port Qos Priority values are: low(0) -- low prority high(1) -- high prority. The BigIron Port Qos Priority values are: level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) " ::= { snSwPortInfoEntry 10 } snSwPortInfoPhysAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "The port physical address. The physical address represents the switch port." ::= { snSwPortInfoEntry 11 } snSwPortStatsInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets received on the interface." ::= { snSwPortInfoEntry 12 } snSwPortStatsOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets transmitted out of the interface." ::= { snSwPortInfoEntry 13 } snSwPortStatsAlignErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "dot3StatsAlignmentErrors : A count of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check. The count represented by an instance of this object is incremented when the alignmentError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC." ::= { snSwPortInfoEntry 14 } snSwPortStatsFCSErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "dot3StatsFCSErrors : A count of frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check. The count represented by an instance of this object is incremented when the frameCheckError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC." ::= { snSwPortInfoEntry 15 } snSwPortStatsMultiColliFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "dot3StatsMultipleCollisionFrames : A count of successfully transmitted frames on a particular interface for which transmission is inhibited by more than one collision. A frame that is counted by an instance of this object is also counted by the corresponding instance of either the ifOutUcastPkts, ifOutMulticastPkts, or ifOutBroadcastPkts, and is not counted by the corresponding instance of the dot3StatsSingleCollisionFrames object." ::= { snSwPortInfoEntry 16 } snSwPortStatsFrameTooLongs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "dot3StatsFrameTooLongs : A count of frames received on a particular interface that exceed the maximum permitted frame size. The count represented by an instance of this object is incremented when the frameTooLong status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC." ::= { snSwPortInfoEntry 17 } snSwPortStatsTxColliFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of successfully transmitted frames on a particular interface for which transmission is inhibited by more than one collision. A frame that is counted by a combination of both dot3StatsSingleCollisionFrames and dot3StatsMultipleCollisionFrames objects." ::= { snSwPortInfoEntry 18 } snSwPortStatsRxColliFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of successfully received frames on a particular interface for which transmission is inhibited by more than one collision. This object is not specified in dot3 but it has the same functionarity as snSwPortStatsTxColliFrames." ::= { snSwPortInfoEntry 19 } snSwPortStatsFrameTooShorts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " A count of frames received on a particular interface that below the minimum permitted frame size." ::= { snSwPortInfoEntry 20 } snSwPortLockAddressCount OBJECT-TYPE SYNTAX INTEGER (0..2048) ACCESS read-write STATUS mandatory DESCRIPTION "The number of source MAC addresses are allowed for a port. Writing 0 to this object will allow any number of addresses." DEFVAL { 8 } ::= { snSwPortInfoEntry 21 } snSwPortStpPortEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The enabled/disabled status of the port." REFERENCE "IEEE 802.1D-1990: Section 4.5.5.2, dot1dStpPortEnable" ::= { snSwPortInfoEntry 22 } snSwPortDhcpGateListId OBJECT-TYPE SYNTAX INTEGER (0..32) ACCESS read-write STATUS mandatory DESCRIPTION "The ID for a DHCP gateway list entry relative to this switch port. 0 = unset or no assigned ID" ::= { snSwPortInfoEntry 23 } snSwPortName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "Port Name string." ::= { snSwPortInfoEntry 24 } snSwPortStatsInBcastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of broadcast packets received on the interface." ::= { snSwPortInfoEntry 25 } snSwPortStatsOutBcastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of broadcast packets transmitted out of the interface." ::= { snSwPortInfoEntry 26 } snSwPortStatsInMcastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of multicast packets received on the interface." ::= { snSwPortInfoEntry 27 } snSwPortStatsOutMcastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of multicast packets transmitted out of the interface." ::= { snSwPortInfoEntry 28 } snSwPortStatsInDiscard OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space." ::= { snSwPortInfoEntry 29 } snSwPortStatsOutDiscard OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being transmitted. One possible reason for discarding such a packet could be to free up buffer space." ::= { snSwPortInfoEntry 30 } snSwPortStatsMacStations OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of MAC Stations connected to the interface." ::= { snSwPortInfoEntry 31 } snSwPortCacheGroupId OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Cache Group ID for the interface." ::= { snSwPortInfoEntry 32 } snSwPortTransGroupId OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Transparent Group ID for the interface." ::= { snSwPortInfoEntry 33 } snSwPortInfoAutoNegotiate OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1), negFullAuto(2), global(3), other(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This feature only applies to Gigabit Ethernet ports. If set to disable(0), port will be put to non-negotiation mode. If set to enable(1), port will start auto-negotiation indefinitely until succeed. If set to negFullAuto(2), the port will start with auto- negotiation, if the negotiation failed, then it will automatically switch to non-negotiation mode. Stackable products (except TurboIron 8) Gigabit Ethernet ports do not support negFullAuto(2). If set to global(3), port negotiation mode follows the value of snSwGlobalAutoNegotiate. Non-Gigabit Ethernet port returns the value other(4)." DEFVAL { global } ::= { snSwPortInfoEntry 34 } snSwPortInfoFlowControl OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disbale port flow control." DEFVAL { enabled } ::= { snSwPortInfoEntry 35 } snSwPortInfoGigType OBJECT-TYPE SYNTAX INTEGER { m1000BaseSX(0), m1000BaseLX(1), m1000BaseLH(2), m1000BaseLHA(3), m1000BaseLHB(4), m1000BaseTX(5), m10000BaseSR(6), m10000BaseLR(7), m10000BaseER(8), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "The media type for the port. The values are: m1000BaseSX(0)....1Gbits per second fiber, with a short wavelength transceiver. m1000BaseLX(1)....1Gbits per second fiber, with a long wavelength transceiver (3km). m1000BaseLH(2)....1Gbits per second fiber, with a special wavelength transceiver (50km). m1000BaseLHA(3)....1Gbits per second fiber, with a special wavelength transceiver (70km). m1000BaseLHB(4)....1Gbits per second fiber, with a special wavelength transceiver (150km). m1000BaseTX(5)....1Gbits per second copper (100meter). m10000BaseSR(6)....10Gbits per second fiber, with a short range wavelength transceiver (100m). m10000BaseLR(7)....10Gbits per second fiber, with a long range wavelength transceiver (10km). m10000BaseER(8)....10Gbits per second fiber, with a extended range wavelength transceiver (40km). notApplicable(255)....a non-gigabit port." ::= { snSwPortInfoEntry 36 } snSwPortStatsLinkChange OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of link state change of the interface." ::= { snSwPortInfoEntry 37 } snSwPortIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "In order to identify a particular interface, this object shall identify the instance of the ifIndex object, defined in RFC 1213 and RFC 1573." ::= { snSwPortInfoEntry 38 } snSwPortDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A textual string containing the slot/port information about the interface." ::= { snSwPortInfoEntry 39 } snSwPortInOctets OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets received on the interface, including framing characters. This object is a 64-bit counter of the ifInOctets object, defined in RFC 1213. The octet string is in big-endian byte order." ::= { snSwPortInfoEntry 40 } snSwPortOutOctets OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit counter of the ifOutOctets object, defined in RFC 1213. The octet string is in big-endian byte order." ::= { snSwPortInfoEntry 41 } snSwPortStatsInBitsPerSec OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of bits per second received on the interface over a 5 minutes interval." ::= { snSwPortInfoEntry 42 } snSwPortStatsOutBitsPerSec OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of bits per second transmitted out of the interface over a 5 minutes interval." ::= { snSwPortInfoEntry 43 } snSwPortStatsInPktsPerSec OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets per second received on the interface over a 5 minutes interval." ::= { snSwPortInfoEntry 44 } snSwPortStatsOutPktsPerSec OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets per second transmitted out of the interface over a 5 minutes interval." ::= { snSwPortInfoEntry 45 } snSwPortStatsInUtilization OBJECT-TYPE SYNTAX INTEGER (0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "The input network utilization in hundredths of a percent over a 5 minutes interval." ::= { snSwPortInfoEntry 46 } snSwPortStatsOutUtilization OBJECT-TYPE SYNTAX INTEGER (0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "The output network utilization in hundredths of a percent over a 5 minutes interval." ::= { snSwPortInfoEntry 47 } snSwPortFastSpanPortEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The enabled/disabled fast span port status of the port." ::= { snSwPortInfoEntry 48 } snSwPortFastSpanUplinkEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The enabled/disabled fast span uplink status of the port." ::= { snSwPortInfoEntry 49 } snSwPortVlanId OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "The ID of a VLAN of which this port is a member. Port must be untagged. For tagged port which belongs to multiple VLANs, this object return 0 which is an invalid VLAN ID value." ::= { snSwPortInfoEntry 50 } snSwPortRouteOnly OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable L2 switching of a routing switch port. By default, the routing switch performs routing first. If routing failed, it performs switching. Enable route only instrcuts the routing switch to perform routing only. For a L2 switching only product, reading this object always return 'disabled', writing 'enabled' to this object takes no effect." DEFVAL { disabled } ::= { snSwPortInfoEntry 51 } snSwPortPresent OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicate if the port is absent or present. This object only valid for M4 module " ::= { snSwPortInfoEntry 52 } snSwPortGBICStatus OBJECT-TYPE SYNTAX INTEGER { gbic(1), miniGBIC(2), empty(3), other(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicate if the gig port has GBICs on them. If set to GBIC(1), it means that the port is GBIC. If set to miniGBIC(2), it means that the port miniGBIC. If set to empty(3), it means that the GBIC is missing. Value other(4) means that the port not a removable gig port. " ::= { snSwPortInfoEntry 53 } snSwPortStatsInKiloBitsPerSec OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Bit rate in kilobits per second received on the 10G and faster interface over a 5 minutes interval." ::= { snSwPortInfoEntry 54 } snSwPortStatsOutKiloBitsPerSec OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Bit rate in kilobits per second transmitted out of the 10G and faster interface over a 5 minutes interval." ::= { snSwPortInfoEntry 55 } snSwPortLoadInterval OBJECT-TYPE SYNTAX INTEGER (30..300) ACCESS read-write STATUS mandatory DESCRIPTION "The time in seconds for which average port utilization should be carried out. The value should be incremental of 30 seconds, between the ranges specified." DEFVAL { 300 } ::= { snSwPortInfoEntry 56 } snSwPortTagType OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The IEEE802.1q tag type embedded in the length/type field of an Ethernet packet. It specifies that the 2 octets after the length/type field in an Ethernet packet is the tag value." DEFVAL { 33024 } ::= { snSwPortInfoEntry 57 } -- Interface ID Registration Group snInterfaceId OBJECT IDENTIFIER ::= { snSwPortInfo 2 } -- Interface ID to ifIndex Lookup Table -- Given an interface ID, this table returns the ifIndex value. -- -- Note: This table does not behave like most SNMP tables. It does not -- support GetNext. If you try to walk the table using GetNext, no rows -- will be returned. The contents of the table can only be accessed -- using Get operations. The table is useful for mapping a known -- interface to the corresponding ifIndex value. snInterfaceLookupTable OBJECT-TYPE SYNTAX SEQUENCE OF SnInterfaceLookupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { snSwPortInfo 3 } snInterfaceLookupEntry OBJECT-TYPE SYNTAX SnInterfaceLookupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { snInterfaceLookupInterfaceId } ::= { snInterfaceLookupTable 1 } SnInterfaceLookupEntry ::= SEQUENCE { snInterfaceLookupInterfaceId InterfaceId, snInterfaceLookupIfIndex INTEGER } snInterfaceLookupInterfaceId OBJECT-TYPE SYNTAX InterfaceId ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { snInterfaceLookupEntry 1 } snInterfaceLookupIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { snInterfaceLookupEntry 2 } -- ifIndex to Interface ID Lookup Table -- Given an ifIndex, this table returns the interface ID value. snIfIndexLookupTable OBJECT-TYPE SYNTAX SEQUENCE OF SnIfIndexLookupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { snSwPortInfo 4 } snIfIndexLookupEntry OBJECT-TYPE SYNTAX SnIfIndexLookupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { snIfIndexLookupIfIndex } ::= { snIfIndexLookupTable 1 } SnIfIndexLookupEntry ::= SEQUENCE { snIfIndexLookupIfIndex INTEGER, snIfIndexLookupInterfaceId InterfaceId } snIfIndexLookupIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { snIfIndexLookupEntry 1 } snIfIndexLookupInterfaceId OBJECT-TYPE SYNTAX InterfaceId ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { snIfIndexLookupEntry 2 } -- Forwarding Database Group -- -- This group contains information relevant to -- the forwarding database in the system. -- The Forward Database Static Table Information -- -- This table contains all MAC addresses in the system. Static -- stations may be configured. snFdbTable OBJECT-TYPE SYNTAX SEQUENCE OF SnFdbEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains snFdb information for each station known to the system, one entry per station." ::= { snFdbInfo 1 } snFdbEntry OBJECT-TYPE SYNTAX SnFdbEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry represents the information of a static MAC station." INDEX { snFdbStationIndex } ::= { snFdbTable 1 } SnFdbEntry ::= SEQUENCE { snFdbStationIndex INTEGER, snFdbStationAddr PhysAddress, snFdbStationPort INTEGER, snFdbVLanId INTEGER, snFdbStationQos INTEGER, snFdbStationType INTEGER, snFdbRowStatus INTEGER } snFdbStationIndex OBJECT-TYPE SYNTAX INTEGER (1..256) ACCESS read-only STATUS mandatory DESCRIPTION "The FDB Station index to the Fdb Station Table." ::= { snFdbEntry 1 } snFdbStationAddr OBJECT-TYPE SYNTAX PhysAddress ACCESS read-write STATUS mandatory DESCRIPTION "The snFdbs physical address. The physical address represents a MAC Station." ::= { snFdbEntry 2 } snFdbStationPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Station slot/port number. The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number (slot for chassis only)." ::= { snFdbEntry 3 } snFdbVLanId OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The Station VLan ID." ::= { snFdbEntry 4 } snFdbStationQos OBJECT-TYPE SYNTAX INTEGER { level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The Stand alone stackable station Qos Priority values are: low(0) -- low prority high(1) -- high prority. The BigIron switch station Priority values are: level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) " ::= { snFdbEntry 5 } snFdbStationType OBJECT-TYPE SYNTAX INTEGER { notSupported(0), host(1), router(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The station type values are: notSupported -- a read value only : this product does not support MultiLayer Switching. host -- any MAC station. router -- a router-typed station." ::= { snFdbEntry 6 } snFdbRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid" ::= { snFdbEntry 7 } -- Port STP Configuration Group snPortStpTable OBJECT-TYPE SYNTAX SEQUENCE OF SnPortStpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A specific snPortStpTable consists of a number of switch ports. This table only exists if only if snVLanByPortTable exists and snVLanByPortStpMode is enabled for each VLAN." ::= { snPortStpInfo 1 } snPortStpEntry OBJECT-TYPE SYNTAX SnPortStpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the snPortStpTable indicates the configuration on a specified port. A SNMP SET PDU for a row of the snPortStpTable requires the entired sequence of the MIB Objects in each snPortStpEntry stored in one PDU. Otherwise, GENERR return-value will be returned." INDEX { snPortStpVLanId, snPortStpPortNum } ::= { snPortStpTable 1 } SnPortStpEntry ::= SEQUENCE { snPortStpVLanId INTEGER, snPortStpPortNum INTEGER, snPortStpPortPriority INTEGER, snPortStpPathCost INTEGER, snPortStpOperState INTEGER, snPortStpPortEnable INTEGER, snPortStpPortForwardTransitions Counter, snPortStpPortState INTEGER, snPortStpPortDesignatedCost INTEGER, snPortStpPortDesignatedRoot BridgeId, snPortStpPortDesignatedBridge BridgeId, snPortStpPortDesignatedPort OCTET STRING } snPortStpVLanId OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The VLAN ID of the VLAN switch community." ::= { snPortStpEntry 1 } snPortStpPortNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number of the Switch. The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number (slot for chassis only)." ::= { snPortStpEntry 2 } snPortStpPortPriority OBJECT-TYPE SYNTAX INTEGER (8..255) ACCESS read-write STATUS mandatory DESCRIPTION "The value of the priority field which is contained in the first (in network byte order) octet of the (2 octet long) Port ID. The other octet of the Port ID is given by the value of dot1dStpPort." ::= { snPortStpEntry 3 } snPortStpPathCost OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "dot1dStpPortPathCost : The contribution of this port to the path cost of paths towards the spanning tree root which include this port. 802.1D-1990 recommends that the default value of this parameter be in inverse proportion to the speed of the attached LAN. Writing value zero to this object sets path cost to a default value which automatically changes according to port speed. Reading value zero indicates an unknown path cost value because port speed cannot be determined due to speed auto sense in progress." ::= { snPortStpEntry 4 } snPortStpOperState OBJECT-TYPE SYNTAX INTEGER { notActivated(0), activated(1) } ACCESS read-only STATUS mandatory DESCRIPTION "By default, this mode is set to notActivated(0). notActivated(0)...the Port STP entry is not activated and not in running mode. activated(1)......the Port STP entry is activated and in running mode" ::= { snPortStpEntry 5 } snPortStpPortEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS not-accessible STATUS mandatory DESCRIPTION "The enabled/disabled status of the port." ::= { snPortStpEntry 6 } snPortStpPortForwardTransitions OBJECT-TYPE SYNTAX Counter ACCESS not-accessible STATUS mandatory DESCRIPTION "The number of times this port has transitioned from the Learning state to the Forwarding state." ::= { snPortStpEntry 7 } snPortStpPortState OBJECT-TYPE SYNTAX INTEGER { disabled(1), blocking(2), listening(3), learning(4), forwarding(5), broken(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The port's current state as defined by application of the Spanning Tree Protocol. This state controls what action a port takes on reception of a frame. If the bridge has detected a port that is malfunctioning it will place that port into the broken(6) state. For ports which are disabled (see dot1dStpPortEnable), this object will have a value of disabled(1)." ::= { snPortStpEntry 8 } snPortStpPortDesignatedCost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The path cost of the Designated Port of the segment connected to this port. This value is compared to the Root Path Cost field in received bridge PDUs." ::= { snPortStpEntry 9 } snPortStpPortDesignatedRoot OBJECT-TYPE SYNTAX BridgeId ACCESS read-only STATUS mandatory DESCRIPTION "The unique Bridge Identifier of the Bridge recorded as the Root in the Configuration BPDUs transmitted by the Designated Bridge for the segment to which the port is attached." ::= { snPortStpEntry 10 } snPortStpPortDesignatedBridge OBJECT-TYPE SYNTAX BridgeId ACCESS read-only STATUS mandatory DESCRIPTION "The Bridge Identifier of the bridge which this port considers to be the Designated Bridge for this port's segment." ::= { snPortStpEntry 11 } snPortStpPortDesignatedPort OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "The Port Identifier of the port on the Designated Bridge for this port's segment." ::= { snPortStpEntry 12 } -- Trunk Port Configuration Group snTrunkTable OBJECT-TYPE SYNTAX SEQUENCE OF SnTrunkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A specific snTrunkTable consists of a number of Trunk port-mask." ::= { snTrunkInfo 1 } snTrunkEntry OBJECT-TYPE SYNTAX SnTrunkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the snTrunkTable indicates the configuration on a specified Trunk port membership." INDEX { snTrunkIndex } ::= { snTrunkTable 1 } SnTrunkEntry ::= SEQUENCE { snTrunkIndex INTEGER, snTrunkPortMask PortMask, snTrunkType INTEGER } snTrunkIndex OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-only STATUS mandatory DESCRIPTION "The number of the trunk entries can be configured." ::= { snTrunkEntry 1 } snTrunkPortMask OBJECT-TYPE SYNTAX PortMask ACCESS read-write STATUS mandatory DESCRIPTION "Trunk membership of the Switch." ::= { snTrunkEntry 2 } snTrunkType OBJECT-TYPE SYNTAX INTEGER { switch(1), server(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The trunk connection type which specifies what device the trunk ports are connected to." ::= { snTrunkEntry 3 } -- Multi-slot Trunk Port Configuration Group snMSTrunkTable OBJECT-TYPE SYNTAX SEQUENCE OF SnMSTrunkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table contains the configuration of port members of multi-slot trunk groups." ::= { snTrunkInfo 2 } snMSTrunkEntry OBJECT-TYPE SYNTAX SnMSTrunkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the snMSTrunkTable." INDEX {snMSTrunkPortIndex} ::= { snMSTrunkTable 1 } SnMSTrunkEntry ::= SEQUENCE { snMSTrunkPortIndex INTEGER, snMSTrunkPortList OCTET STRING, snMSTrunkType INTEGER, snMSTrunkRowStatus INTEGER } snMSTrunkPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The primary port of a trunk group. For module with Gig ports, primary port is port 1, 3, 5, 7. For module with 10/100 ports, primary port is port 1, 5, 9, 13, 17, 21." ::= { snMSTrunkEntry 1 } snMSTrunkPortList OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A list of port indices which are the port membership of a trunk group. Each port index is a 16-bit integer in big endian order. The first port index must be the primary port index." ::= { snMSTrunkEntry 2 } snMSTrunkType OBJECT-TYPE SYNTAX INTEGER { switch(1), server(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The trunk connection type which specifies what device the trunk ports are connected to." ::= { snMSTrunkEntry 3 } snMSTrunkRowStatus OBJECT-TYPE SYNTAX INTEGER { invalid(1), valid(2), delete(3), create(4), modify(5) } ACCESS read-write STATUS mandatory DESCRIPTION "To create or delete a table entry." ::= { snMSTrunkEntry 4 } -- Switch Configuration Summary Group snSwSummaryMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The Switch Group Configuration Summary is configured either enabled or disabled and the default is disabled mode. enabled(1)...........activate Switch Configuration Summary. disabled(0)..........no Switch Configuration Summary." ::= { snSwSummary 1 } --- DHCP Gateway List Table snDhcpGatewayListTable OBJECT-TYPE SYNTAX SEQUENCE OF SnDhcpGatewayListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of DHCP gateway list of addresses." ::= { snDhcpGatewayListInfo 1 } snDhcpGatewayListEntry OBJECT-TYPE SYNTAX SnDhcpGatewayListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the IP Port Address table." INDEX { snDhcpGatewayListId } ::= { snDhcpGatewayListTable 1 } SnDhcpGatewayListEntry ::= SEQUENCE { snDhcpGatewayListId INTEGER, snDhcpGatewayListAddrList OCTET STRING, snDhcpGatewayListRowStatus INTEGER } snDhcpGatewayListId OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "The ID for a DHCP gateway list entry." ::= { snDhcpGatewayListEntry 1 } snDhcpGatewayListAddrList OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4..32)) ACCESS read-write STATUS mandatory DESCRIPTION "The DHCP gateway address list for each DHCP gateway list ID. This list contains 1 to 8 IP addresses represented by octet string." ::= { snDhcpGatewayListEntry 2 } snDhcpGatewayListRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row or modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid" ::= { snDhcpGatewayListEntry 3 } -- DNS MIB Group snDnsDomainName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..80)) ACCESS read-write STATUS mandatory DESCRIPTION "DNS Domain Name string." ::= { snDnsInfo 1 } snDnsGatewayIpAddrList OBJECT-TYPE SYNTAX OCTET STRING (SIZE(16)) ACCESS read-write STATUS mandatory DESCRIPTION "The DNS Gateway IP address list. This list contains 4 IP addresses represented by octet string." ::= { snDnsInfo 2 } -- MAC filter table snMacFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF SnMacFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "MAC filter table." ::= { snMacFilter 1 } snMacFilterEntry OBJECT-TYPE SYNTAX SnMacFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the MAC filter table." INDEX { snMacFilterIndex } ::= { snMacFilterTable 1 } SnMacFilterEntry ::= SEQUENCE { snMacFilterIndex INTEGER, snMacFilterAction INTEGER, snMacFilterSourceMac MacAddress, snMacFilterSourceMask MacAddress, snMacFilterDestMac MacAddress, snMacFilterDestMask MacAddress, snMacFilterOperator INTEGER, snMacFilterFrameType INTEGER, snMacFilterFrameTypeNum INTEGER, snMacFilterRowStatus INTEGER } snMacFilterIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The table index for a filter entry." ::= { snMacFilterEntry 1 } snMacFilterAction OBJECT-TYPE SYNTAX INTEGER { deny(0), permit(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Action to take if the Mac packet match with this filter." ::= { snMacFilterEntry 2 } snMacFilterSourceMac OBJECT-TYPE SYNTAX MacAddress ACCESS read-write STATUS mandatory DESCRIPTION "Source MAC address." ::= { snMacFilterEntry 3 } snMacFilterSourceMask OBJECT-TYPE SYNTAX MacAddress ACCESS read-write STATUS mandatory DESCRIPTION "Source MAC subnet mask." ::= { snMacFilterEntry 4 } snMacFilterDestMac OBJECT-TYPE SYNTAX MacAddress ACCESS read-write STATUS mandatory DESCRIPTION "Destination MAC address." ::= { snMacFilterEntry 5 } snMacFilterDestMask OBJECT-TYPE SYNTAX MacAddress ACCESS read-write STATUS mandatory DESCRIPTION "Destination MAC subnet mask." ::= { snMacFilterEntry 6 } snMacFilterOperator OBJECT-TYPE SYNTAX INTEGER { equal(0), notEqual(1), less(2), greater(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of comparison to perform." ::= { snMacFilterEntry 7 } snMacFilterFrameType OBJECT-TYPE SYNTAX INTEGER{ notUsed(0), ethernet(1), llc(2), snap(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Frame Type: ethernet-type, LLC and SNAP types" ::= { snMacFilterEntry 8 } snMacFilterFrameTypeNum OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Frame Type Number. 0 means NA" ::= { snMacFilterEntry 9 } snMacFilterRowStatus OBJECT-TYPE SYNTAX INTEGER { invalid(1), valid(2), delete(3), create(4), modify(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row modify(5)...modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row invalid(1)...Setting it to 'invalid' has the effect of rendering it inoperative.. valid(2)....the row exists and is valid" ::= { snMacFilterEntry 10 } -- MAC Filter Port access table snMacFilterPortAccessTable OBJECT-TYPE SYNTAX SEQUENCE OF SnMacFilterPortAccessEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "MAC Filter port access table." ::= { snMacFilter 2 } snMacFilterPortAccessEntry OBJECT-TYPE SYNTAX SnMacFilterPortAccessEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the MAC Filter Port access table." INDEX { snMacFilterPortAccessPortIndex } ::= { snMacFilterPortAccessTable 1 } SnMacFilterPortAccessEntry ::= SEQUENCE { snMacFilterPortAccessPortIndex INTEGER, snMacFilterPortAccessFilters OCTET STRING, snMacFilterPortAccessRowStatus INTEGER } snMacFilterPortAccessPortIndex OBJECT-TYPE SYNTAX INTEGER (1..3900) ACCESS read-only STATUS mandatory DESCRIPTION "The port index. For FastIron/NetIron products, port index value is from 1 to 42 For BigIron products, port index is an encoded number: The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number. For virtual router interface, slot number is 15, port number is the virtual router port from 1 to 60. Therefore, port index value for BigIron is from 257 to 3900." ::= { snMacFilterPortAccessEntry 1 } snMacFilterPortAccessFilters OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "1st octet correspond to 1st filter number and so on." ::= { snMacFilterPortAccessEntry 2 } snMacFilterPortAccessRowStatus OBJECT-TYPE SYNTAX INTEGER { invalid(1), valid(2), delete(3), create(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row invalid(1)...Setting it to 'invalid' has the effect of rendering it inoperative.. valid(2)....the row exists and is valid" ::= { snMacFilterPortAccessEntry 3 } -- NTP general group snNTPGeneral OBJECT IDENTIFIER ::= { snNTP 1 } snNTPPollInterval OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Interval specifies how often to poll the NTP server. Each unit is one second." DEFVAL { 1800 } ::= { snNTPGeneral 1 } snNTPTimeZone OBJECT-TYPE SYNTAX INTEGER { alaska(0), aleutian(1), arizona(2), central(3), eastIndiana(4), eastern(5), hawaii(6), michigan(7), mountain(8), pacific(9), samoa(10), gmtPlus12(11), gmtPlus11(12), gmtPlus10(13), gmtPlus9(14), gmtPlus8(15), gmtPlus7(16), gmtPlus6(17), gmtPlus5(18), gmtPlus4(19), gmtPlus3(20), gmtPlus2(21), gmtPlus1(22), gmt(23), gmtMinus1(24), gmtMinus2(25), gmtMinus3(26), gmtMinus4(27), gmtMinus5(28), gmtMinus6(29), gmtMinus7(30), gmtMinus8(31), gmtMinus9(32), gmtMinus10(33), gmtMinus11(34), gmtMinus12(35) } ACCESS read-write STATUS mandatory DESCRIPTION "Time zone." DEFVAL { gmt } ::= { snNTPGeneral 2 } snNTPSummerTimeEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled (1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable daylight saving time. This enables daylight saving time for time/date starting 02:00:00 of first Sunday in April and ending 02:00:00 of last Sunday in October every year." DEFVAL { disabled } ::= { snNTPGeneral 3 } snNTPSystemClock OBJECT-TYPE SYNTAX OCTET STRING (SIZE (7)) ACCESS read-write STATUS mandatory DESCRIPTION "System clock, in the following format: octet 0: seconds after the minute [0-60] octet 1: minutes after the hour [0-59] octet 2: hours since midnight [0-23] octet 3: day of the month [1-31] octet 4: months since January [0-11] octet 5: years since 1900 octet 6: days since Sunday [0-6] Setting this object requires valid value in octets 0 to 5, and zero in octet 6. System clock can be disabled by setting zero to all octets." ::= { snNTPGeneral 4 } snNTPSync OBJECT-TYPE SYNTAX INTEGER { other(1), synchronize(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Initiate time synchronization to the NTP servers. For set operation, only 'synchronize(2)' is accepted. For get operation, always return 'other(1)'." ::= { snNTPGeneral 5 } -- NTP server table snNTPServerTable OBJECT-TYPE SYNTAX SEQUENCE OF SnNTPServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "NTP (Network Time Protocol) server table." ::= { snNTP 2 } snNTPServerEntry OBJECT-TYPE SYNTAX SnNTPServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the NTP server table." INDEX { snNTPServerIp } ::= { snNTPServerTable 1 } SnNTPServerEntry ::= SEQUENCE { snNTPServerIp IpAddress, snNTPServerVersion INTEGER, snNTPServerRowStatus INTEGER } snNTPServerIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "NTP server IP address." ::= { snNTPServerEntry 1 } snNTPServerVersion OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-write STATUS mandatory DESCRIPTION "NTP server version." DEFVAL { 1 } ::= { snNTPServerEntry 2 } snNTPServerRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4) } ACCESS read-write STATUS mandatory DESCRIPTION "To create or delete a NTP server table entry." ::= { snNTPServerEntry 3 } -- Radius general group snRadiusGeneral OBJECT IDENTIFIER ::= { snRadius 1 } snRadiusSNMPAccess OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicate whether Radius group MIB obejcts can be accessed by SNMP manager. If value is disabled, all Radius group MIB objects return 'general error'." DEFVAL { disabled } ::= { snRadiusGeneral 1 } snRadiusEnableTelnetAuth OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable telnet authentication specified by 'snRadiusLoginMethod'." DEFVAL { disabled } ::= { snRadiusGeneral 2 } snRadiusRetransmit OBJECT-TYPE SYNTAX INTEGER (0..5) ACCESS read-write STATUS mandatory DESCRIPTION "The number of authentication query retransmissions to the Radius server." DEFVAL { 3 } ::= { snRadiusGeneral 3 } snRadiusTimeOut OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-write STATUS mandatory DESCRIPTION "Interval specifies how long to wait for authentication reply from the Radius server, each unit is one second." DEFVAL { 3 } ::= { snRadiusGeneral 4 } snRadiusDeadTime OBJECT-TYPE SYNTAX INTEGER (1..5) ACCESS read-write STATUS mandatory DESCRIPTION "Interval specifies Radius server dead time, each unit is one minute." DEFVAL { 3 } ::= { snRadiusGeneral 5 } snRadiusKey OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Authentication key displayed as encrypted text." ::= { snRadiusGeneral 6 } snRadiusLoginMethod OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..7)) ACCESS read-write STATUS mandatory DESCRIPTION "A sequence of authentication methods. Each octet represents a method to authenticate the user login process. Each octet has the following enumeration value: enable(1) - authenticate by command line interface enable password radius(2) - authenticate by requesting radius server local(3) - authenticate by local user account table line(4) - authenticate by telnet password tacplus(5) - authenticate by requesting tacplus server none(6) - do not authenticate tacacs(7) - authenticate by requesting tacacs server Setting a zero length octet string invalidates all previous authentication methods." ::= { snRadiusGeneral 7 } snRadiusEnableMethod OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..7)) ACCESS read-write STATUS mandatory DESCRIPTION "A sequence of authentication methods. Each octet represents a method to authenticate the user entering priviledge mode of the command line interface. Each octet has the following enumeration value: enable(1) - authenticate by command line interface enable password radius(2) - authenticate by requesting radius server local(3) - authenticate by local user account table line(4) - authenticate by telnet password tacplus(5) - authenticate by requesting tacplus server none(6) - do not authenticate tacacs(7) - authenticate by requesting tacacs server Setting a zero length octet string invalidates all previous authentication methods." ::= { snRadiusGeneral 8 } snRadiusWebServerMethod OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..7)) ACCESS read-write STATUS mandatory DESCRIPTION "A sequence of authentication methods. Each octet represents a method to authenticate the user accessing the web-server. Each octet has the following enumeration value: enable(1) - authenticate by command line interface enable password radius(2) - authenticate by requesting radius server local(3) - authenticate by local user account table line(4) - authenticate by telnet password tacplus(5) - authenticate by requesting tacplus server none(6) - do not authenticate tacacs(7) - authenticate by requesting tacacs server Setting a zero length octet string invalidates all previous authentication methods." ::= { snRadiusGeneral 9 } snRadiusSNMPServerMethod OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..7)) ACCESS read-write STATUS mandatory DESCRIPTION "A sequence of authentication methods. Each octet represents a method to authenticate the user accessing the snmp-server. Each octet has the following enumeration value: enable(1) - authenticate by command line interface enable password radius(2) - authenticate by requesting radius server local(3) - authenticate by local user account table line(4) - authenticate by telnet password tacplus(5) - authenticate by requesting tacplus server none(6) - do not authenticate tacacs(7) - authenticate by requesting tacacs server Setting a zero length octet string invalidates all previous authentication methods." ::= { snRadiusGeneral 10 } -- Radius server table snRadiusServerTable OBJECT-TYPE SYNTAX SEQUENCE OF SnRadiusServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Radius server table." ::= { snRadius 2 } snRadiusServerEntry OBJECT-TYPE SYNTAX SnRadiusServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Radius server table." INDEX { snRadiusServerIp } ::= { snRadiusServerTable 1 } SnRadiusServerEntry ::= SEQUENCE { snRadiusServerIp IpAddress, snRadiusServerAuthPort INTEGER, snRadiusServerAcctPort INTEGER, snRadiusServerRowStatus INTEGER, snRadiusServerRowKey DisplayString, snRadiusServerUsage INTEGER } snRadiusServerIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Radius server IP address." ::= { snRadiusServerEntry 1 } snRadiusServerAuthPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Authentication UDP port number." DEFVAL { 1645 } ::= { snRadiusServerEntry 2 } snRadiusServerAcctPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Account UDP port number." DEFVAL { 1646 } ::= { snRadiusServerEntry 3 } snRadiusServerRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4) } ACCESS read-write STATUS mandatory DESCRIPTION "To create or delete a Radius server table entry." ::= { snRadiusServerEntry 4 } snRadiusServerRowKey OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Authentication key displayed as encrypted text." ::= { snRadiusServerEntry 5 } snRadiusServerUsage OBJECT-TYPE SYNTAX INTEGER { default(1), authentication-only(2), authorization-only(3), accounting-only(4) } ACCESS read-write STATUS mandatory DESCRIPTION "To allow this server to be dedicated for a particular AAA activity." ::= { snRadiusServerEntry 6 } --- Tacacs General MIBs snTacacsGeneral OBJECT IDENTIFIER ::= { snTacacs 1 } snTacacsRetransmit OBJECT-TYPE SYNTAX INTEGER (0..5) ACCESS read-write STATUS mandatory DESCRIPTION "The number of authentication query retransmissions to the Tacacs server." DEFVAL { 3 } ::= { snTacacsGeneral 1 } snTacacsTimeOut OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-write STATUS mandatory DESCRIPTION "Interval specifies how long to wait for authentication reply from the Tacacs server, each unit is one second." DEFVAL { 3 } ::= { snTacacsGeneral 2 } snTacacsDeadTime OBJECT-TYPE SYNTAX INTEGER (1..5) ACCESS read-write STATUS mandatory DESCRIPTION "Interval specifies Tacacs server dead time, each unit is one minute." DEFVAL { 3 } ::= { snTacacsGeneral 3 } snTacacsKey OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Authentication key displayed as encrypted text." ::= { snTacacsGeneral 4 } snTacacsSNMPAccess OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicate whether Tacacs group MIB obejcts can be accessed by SNMP manager. If value is disabled, all Tacacs group MIB objects return 'general error'." DEFVAL { disabled } ::= { snTacacsGeneral 5 } -- Tacacs server table snTacacsServerTable OBJECT-TYPE SYNTAX SEQUENCE OF SnTacacsServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Tacacs server table." ::= { snTacacs 2 } snTacacsServerEntry OBJECT-TYPE SYNTAX SnTacacsServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Tacacs server table." INDEX { snTacacsServerIp } ::= { snTacacsServerTable 1 } SnTacacsServerEntry ::= SEQUENCE { snTacacsServerIp IpAddress, snTacacsServerAuthPort INTEGER, snTacacsServerRowStatus INTEGER, snTacacsServerRowKey DisplayString, snTacacsServerUsage INTEGER } snTacacsServerIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Tacacs server IP address." ::= { snTacacsServerEntry 1 } snTacacsServerAuthPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Authentication UDP port number." DEFVAL { 49 } ::= { snTacacsServerEntry 2 } snTacacsServerRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4) } ACCESS read-write STATUS mandatory DESCRIPTION "To create or delete a Tacacs server table entry." ::= { snTacacsServerEntry 3 } snTacacsServerRowKey OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Authentication key displayed as encrypted text." ::= { snTacacsServerEntry 4 } snTacacsServerUsage OBJECT-TYPE SYNTAX INTEGER { default(1), authentication-only(2), authorization-only(3), accounting-only(4) } ACCESS read-write STATUS mandatory DESCRIPTION "To allow this server to be dedicated for a particular AAA activity." ::= { snTacacsServerEntry 5 } -- QOS Profile Group snQosProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF SnQosProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table contains the configuration of qos profile groups." ::= { snQos 1 } snQosProfileEntry OBJECT-TYPE SYNTAX SnQosProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the snQosProfileTable." INDEX {snQosProfileIndex} ::= { snQosProfileTable 1 } SnQosProfileEntry ::= SEQUENCE { snQosProfileIndex INTEGER, snQosProfileName DisplayString, snQosProfileRequestedBandwidth INTEGER, snQosProfileCalculatedBandwidth INTEGER } snQosProfileIndex OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "The table index of QOS Profile." ::= { snQosProfileEntry 1 } snQosProfileName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Qos Profile Name string." ::= { snQosProfileEntry 2 } snQosProfileRequestedBandwidth OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Qos Profile Requested Bandwidth." ::= { snQosProfileEntry 3 } snQosProfileCalculatedBandwidth OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Qos Profile Calculated Bandwidth." ::= { snQosProfileEntry 4 } -- QOS Bind Group snQosBindTable OBJECT-TYPE SYNTAX SEQUENCE OF SnQosBindEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table contains the configuration of 802.1p to qos profile binding groups." ::= { snQos 2 } snQosBindEntry OBJECT-TYPE SYNTAX SnQosBindEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the snQosBindTable." INDEX {snQosBindIndex} ::= { snQosBindTable 1 } SnQosBindEntry ::= SEQUENCE { snQosBindIndex INTEGER, snQosBindPriority INTEGER, snQosBindProfileIndex INTEGER } snQosBindIndex OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "The table index of QOS Bind." ::= { snQosBindEntry 1 } snQosBindPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "QOS bind priority." ::= { snQosBindEntry 2 } snQosBindProfileIndex OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-write STATUS mandatory DESCRIPTION "QOS Bind Profile Index. This is pointer to the index of snQosProfile Table." ::= { snQosBindEntry 3 } -- AAA Mib snAuthentication OBJECT IDENTIFIER ::= { snAAA 1 } snAuthorization OBJECT IDENTIFIER ::= { snAAA 2 } snAccounting OBJECT IDENTIFIER ::= { snAAA 3 } snAuthorizationCommandMethods OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..3)) ACCESS read-write STATUS mandatory DESCRIPTION "A sequence of authorization methods. Each octet represents a method to authorize the user command. Each octet has the following value: radius(2) - authorize by requesting radius server tacplus(5) - authorize by requesting tacplus server none(6) - skip authorization Setting a zero length octet string invalidates all previous authorization methods." ::= { snAuthorization 1 } snAuthorizationCommandLevel OBJECT-TYPE SYNTAX INTEGER { level0(0), level4(4), level5(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Commands, which are equal to and less than the specified command level here needs to be authorized. Possible enumeration values: 0 - Privilege level 0 4 - Privilege level 4 5 - Privilege level 5." ::= { snAuthorization 2 } snAuthorizationExec OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..3)) ACCESS read-write STATUS mandatory DESCRIPTION "A sequence of exec authorization methods. Each octet represents a method for telnet or SSH login authorization. Each octet has the following enumeration value: radius(2) - send exec authorization request to radius server tacplus(5) - send exec authorization request to tacplus server none(6) - no exec authorization Setting a zero length octet string invalidates all authorization methods." ::= { snAuthorization 3 } snAccountingCommandMethods OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..3)) ACCESS read-write STATUS mandatory DESCRIPTION "A sequence of accounting methods. Each octet represents a method to account for the user command. Each octet has the following enumeration value: radius(2) - send accounting info to radius server tacplus(5) - send accounting info to tacplus server none(6) - skip accounting Setting a zero length octet string invalidates all previous accounting methods." ::= { snAccounting 1 } snAccountingCommandLevel OBJECT-TYPE SYNTAX INTEGER { level0(0), level4(4), level5(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Commands, which are equal to and less than the specified command level here will be accounted. Possible enumeration values: level0 - Privilege level 0 level4 - Privilege level 4 level5 - Privilege level 5." ::= { snAccounting 2 } snAccountingExec OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..3)) ACCESS read-write STATUS mandatory DESCRIPTION "A sequence of accounting methods. Each octet represents a method for telnet or SSH login accounting. Each octet has the following enumeration value: radius(2) - send accounting info to radius server tacplus(5) - send accounting info to tacplus server none(6) - skip accounting Setting a zero length octet string invalidates all previous accounting methods." ::= { snAccounting 3 } snAccountingSystem OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..3)) ACCESS read-write STATUS mandatory DESCRIPTION "A sequence of accounting methods. Each octet represents a method to account for the system related events. Each octet has the following enumeration value: radius(2) - send accounting info to radius server tacplus(5) - send accounting info to tacplus server none(6) - skip accounting Setting a zero length octet string invalidates all previous accounting methods." ::= { snAccounting 4 } -- NetFlow Mib snNetFlowGlb OBJECT IDENTIFIER ::= { snNetFlow 1 } snNetFlowGblEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable NetFlow export operation." DEFVAL { disabled } ::= { snNetFlowGlb 1 } snNetFlowGblVersion OBJECT-TYPE SYNTAX INTEGER { version1 (1), version5 (5) } ACCESS read-write STATUS mandatory DESCRIPTION "NetFlow export version." DEFVAL { version5 } ::= { snNetFlowGlb 2 } snNetFlowGblProtocolDisable OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "bit 0 - other, disable all protocols export except UDP and TCP bit 1 - tcp, disable TCP protocol export bit 2 - udp, disable UDP protocol export" DEFVAL { 0 } ::= { snNetFlowGlb 3 } snNetFlowGblActiveTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Maximum time an active flow can be in the NetFlow cache (minutes: 1..60)" DEFVAL { 60 } ::= { snNetFlowGlb 4 } snNetFlowGblInactiveTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Maximum time an inactive flow can be in the NetFlow cache (seconds: 10..600)" DEFVAL { 60 } ::= { snNetFlowGlb 5 } -- NetFlow Collector Table snNetFlowCollectorTable OBJECT-TYPE SYNTAX SEQUENCE OF SnNetFlowCollectorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of each NetFlow collector information." ::= { snNetFlow 2 } snNetFlowCollectorEntry OBJECT-TYPE SYNTAX SnNetFlowCollectorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row in the NetFlow collector table." INDEX { snNetFlowCollectorIndex } ::= { snNetFlowCollectorTable 1 } SnNetFlowCollectorEntry ::= SEQUENCE { snNetFlowCollectorIndex INTEGER, snNetFlowCollectorIp IpAddress, snNetFlowCollectorUdpPort INTEGER, snNetFlowCollectorSourceInterface INTEGER, snNetFlowCollectorRowStatus INTEGER } snNetFlowCollectorIndex OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-only STATUS mandatory DESCRIPTION "The index to the NetFlow collector table." ::= { snNetFlowCollectorEntry 1 } snNetFlowCollectorIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The NetFlow collector ip address." ::= { snNetFlowCollectorEntry 2 } snNetFlowCollectorUdpPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The NetFlow collector UDP port number." ::= { snNetFlowCollectorEntry 3 } snNetFlowCollectorSourceInterface OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The ifIndex value to specify source port to export NetFlow packet. Value 0 to indicate default outgoing port." ::= { snNetFlowCollectorEntry 4 } snNetFlowCollectorRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4) } ACCESS read-write STATUS mandatory DESCRIPTION "To create or delete a NetFlow collector table entry." ::= { snNetFlowCollectorEntry 5 } -- NetFlow Aggregation Table snNetFlowAggregationTable OBJECT-TYPE SYNTAX SEQUENCE OF SnNetFlowAggregationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of each NetFlow aggregation scheme information." ::= { snNetFlow 3 } snNetFlowAggregationEntry OBJECT-TYPE SYNTAX SnNetFlowAggregationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row in the NetFlow Aggregation table." INDEX { snNetFlowAggregationIndex } ::= { snNetFlowAggregationTable 1 } SnNetFlowAggregationEntry ::= SEQUENCE { snNetFlowAggregationIndex INTEGER, snNetFlowAggregationIp IpAddress, snNetFlowAggregationUdpPort INTEGER, snNetFlowAggregationSourceInterface INTEGER, snNetFlowAggregationNumberOfCacheEntries INTEGER, snNetFlowAggregationActiveTimeout INTEGER, snNetFlowAggregationInactiveTimeout INTEGER, snNetFlowAggregationEnable INTEGER, snNetFlowAggregationRowStatus INTEGER } snNetFlowAggregationIndex OBJECT-TYPE SYNTAX INTEGER { as (1), protocolPort (2), destPrefix (3), sourcePrefix (4), prefix (5) } ACCESS read-only STATUS mandatory DESCRIPTION "The Aggregation scheme ID" ::= { snNetFlowAggregationEntry 1 } snNetFlowAggregationIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The NetFlow aggregation collector ip address." ::= { snNetFlowAggregationEntry 2 } snNetFlowAggregationUdpPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The NetFlow aggregation collector UDP port number." ::= { snNetFlowAggregationEntry 3 } snNetFlowAggregationSourceInterface OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The ifIndex value to specify source port to export NetFlow aggregation packet. Value 0 to indicate default outgoing port." ::= { snNetFlowAggregationEntry 4 } snNetFlowAggregationNumberOfCacheEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of cache entries for aggregation scheme" ::= { snNetFlowAggregationEntry 5 } snNetFlowAggregationActiveTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Maximum time an active flow can be in the aggregation cache" ::= { snNetFlowAggregationEntry 6 } snNetFlowAggregationInactiveTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Maximum time an inactive flow can be in the aggregation cache" ::= { snNetFlowAggregationEntry 7 } snNetFlowAggregationEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable NetFlow aggregation for this aggregation scheme." DEFVAL { disabled } ::= { snNetFlowAggregationEntry 8 } snNetFlowAggregationRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4) } ACCESS read-write STATUS mandatory DESCRIPTION "To create or delete a NetFlow collector table entry." ::= { snNetFlowAggregationEntry 9 } -- NetFlow Interface Table -- Table containing information about the switching -- type in every interface. snNetFlowIfTable OBJECT-TYPE SYNTAX SEQUENCE OF SnNetFlowIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of interface entries. The number of entries is given by the value of ifNumber." ::= { snNetFlow 4 } snNetFlowIfEntry OBJECT-TYPE SYNTAX SnNetFlowIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry containing the type of switching performed on that interface." INDEX { snNetFlowIfIndex } ::= { snNetFlowIfTable 1 } SnNetFlowIfEntry ::= SEQUENCE { snNetFlowIfIndex INTEGER, snNetFlowIfFlowSwitching INTEGER } snNetFlowIfIndex OBJECT-TYPE SYNTAX INTEGER (1..65536) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { snNetFlowIfEntry 1 } snNetFlowIfFlowSwitching OBJECT-TYPE SYNTAX INTEGER { disabled (0), enabled (1) } ACCESS read-write STATUS mandatory DESCRIPTION "To enable/disable flow switching in a particular interface: disable (0) - no flow switching enable (1) - flow switching" ::= { snNetFlowIfEntry 2 } -- sFlow Collector Table. snSFlowGlb OBJECT IDENTIFIER ::= { snSFlow 1 } snSflowCollectorTable OBJECT-TYPE SYNTAX SEQUENCE OF SnSflowCollectorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all but first sFlow collectors. The first collector can be configured using sFlowTable in RFC 3176. The RFC cannot be used to configure more than one sFlow collectors. This table has been created to fill this gap." ::= { snSFlow 2 } snSflowCollectorEntry OBJECT-TYPE SYNTAX SnSflowCollectorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row in the sFlow collector table." INDEX { snSflowCollectorIndex } ::= { snSflowCollectorTable 1 } SnSflowCollectorEntry ::= SEQUENCE { snSflowCollectorIndex INTEGER, snSflowCollectorIP IpAddress, snSflowCollectorUDPPort INTEGER, snSflowCollectorRowStatus INTEGER } snSflowCollectorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index to the sFlow collector table." ::= { snSflowCollectorEntry 1 } snSflowCollectorIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The sFlow collector ip address." ::= { snSflowCollectorEntry 2 } snSflowCollectorUDPPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The sFlow collector UDP port number." ::= { snSflowCollectorEntry 3 } snSflowCollectorRowStatus OBJECT-TYPE SYNTAX INTEGER { noSuch(0), other(1), valid(2), delete(3), create(4), modify(5) } ACCESS read-write STATUS mandatory DESCRIPTION "To create, update or delete a SFlow collector table entry. If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid" ::= { snSflowCollectorEntry 4 } snFdpMIBObjects OBJECT IDENTIFIER ::= { snFDP 1 } snFdpInterface OBJECT IDENTIFIER ::= { snFdpMIBObjects 1 } snFdpCache OBJECT IDENTIFIER ::= { snFdpMIBObjects 2 } snFdpGlobal OBJECT IDENTIFIER ::= { snFdpMIBObjects 3 } snFdpCachedAddr OBJECT IDENTIFIER ::= { snFdpMIBObjects 4 } -- -- FDP Interface Group -- snFdpInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF FdpInterfaceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status of FDP on the device's interfaces." ::= { snFdpInterface 1 } snFdpInterfaceEntry OBJECT-TYPE SYNTAX FdpInterfaceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the snFdpInterfaceTable, having the status of FDP on an interface." INDEX { snFdpInterfaceIfIndex } ::= { snFdpInterfaceTable 1 } FdpInterfaceEntry ::= SEQUENCE { snFdpInterfaceIfIndex INTEGER, snFdpInterfaceFdpEnable INTEGER, snFdpInterfaceCdpEnable INTEGER } snFdpInterfaceIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "ifIndex value of the local interface." ::= { snFdpInterfaceEntry 1 } snFdpInterfaceFdpEnable OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The flag, whether the Foundry Discovery Protocol is currently running on this interface. It has no effect when FDP is disabled (snFdpGlobalRun = FALSE)." DEFVAL { true } ::= { snFdpInterfaceEntry 2 } snFdpInterfaceCdpEnable OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The flag, whether the Cisco Discovery Protocol is currently running on this interface. It has no effect when CDP is disabled (snCdpGlobalRun = FALSE)." DEFVAL { true } ::= { snFdpInterfaceEntry 3 } -- -- FDP Cache Table -- snFdpCacheTable OBJECT-TYPE SYNTAX SEQUENCE OF FdpCacheEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table for the cached information obtained via receiving FDP/CDP messages." ::= { snFdpCache 1 } snFdpCacheEntry OBJECT-TYPE SYNTAX FdpCacheEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the snFdpCacheTable, having the information received via FDP/CDP on one interface from one device. Entries appear when a FDP/CDP advertisement is received from a neighbor device. Entries disappear when FDP/CDP is disabled on the interface, or globally." INDEX { snFdpCacheIfIndex, snFdpCacheDeviceIndex } ::= { snFdpCacheTable 1 } FdpCacheEntry ::= SEQUENCE { snFdpCacheIfIndex INTEGER, snFdpCacheDeviceIndex INTEGER, snFdpCacheDeviceId DisplayString, snFdpCacheAddressType INTEGER, snFdpCacheAddress OCTET STRING, snFdpCacheVersion DisplayString, snFdpCacheDevicePort DisplayString, snFdpCachePlatform DisplayString, snFdpCacheCapabilities DisplayString, snFdpCacheVendorId INTEGER, snFdpCacheIsAggregateVlan INTEGER, snFdpCacheTagType INTEGER, snFdpCachePortVlanMask OCTET STRING, snFdpCachePortTagMode INTEGER, snFdpCacheDefaultTrafficeVlanIdForDualMode INTEGER } snFdpCacheIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "ifIndex value of the local interface." ::= { snFdpCacheEntry 1 } snFdpCacheDeviceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Identification of a device, which sent FDP/CDP messages" ::= { snFdpCacheEntry 2 } snFdpCacheDeviceId OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Device-ID string as reported in the most recent FDP/CDP message. The zero-length string indicates no Device-ID field (TLV) was reported in the most recent FDP/CDP message." ::= { snFdpCacheEntry 3 } snFdpCacheAddressType OBJECT-TYPE SYNTAX INTEGER { ip(1), ipx(2), appletalk(3) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication of the type of address contained in the corresponding instance of snFdpCacheAddress." ::= { snFdpCacheEntry 4 } snFdpCacheAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The (first) network-layer address of the device as reported in the most recent FDP/CDP message in the following format: IP address: 4 octets, ip(1) IPX address: 10 octets, ipx(2) First 4-octet as the network number Second 6-octet as the host number Appletalk address: 3 octets, appletalk(3) First 2-octet as the network number Second 1-octet as the host number" ::= { snFdpCacheEntry 5 } snFdpCacheVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Version string as reported in the most recent FDP/CDP message. " ::= { snFdpCacheEntry 6 } snFdpCacheDevicePort OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Port-ID string as reported in the most recent FDP/CDP message. This will typically be the value of the ifName object (e.g., Ethernet0). The zero-length string indicates no Port-ID field (TLV) was reported in the most recent FDP/CDP message." ::= { snFdpCacheEntry 7 } snFdpCachePlatform OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Device's Hardware Platform as reported in the most recent FDP/CDP message. The zero-length string indicates that no Platform field (TLV) was reported in the most recent FDP/CDP message." ::= { snFdpCacheEntry 8 } snFdpCacheCapabilities OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Device's Functional Capabilities as reported in the most recent FDP/CDP message. " ::= { snFdpCacheEntry 9 } snFdpCacheVendorId OBJECT-TYPE SYNTAX INTEGER { fdp(1), cdp(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the entry received by either FDP or CDP." ::= { snFdpCacheEntry 10 } snFdpCacheIsAggregateVlan OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Neighbor device is in aggregated-vlan." ::= { snFdpCacheEntry 11 } snFdpCacheTagType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Neighbor device tag-type." ::= { snFdpCacheEntry 12 } snFdpCachePortVlanMask OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Neighbor device port VLAN masks in 512-byte octet string." ::= { snFdpCacheEntry 13 } snFdpCachePortTagMode OBJECT-TYPE SYNTAX INTEGER { untagged(1), tagged(2), dual(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Neighbor device port tag mode" ::= { snFdpCacheEntry 14 } snFdpCacheDefaultTrafficeVlanIdForDualMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Default traffic vlan id for neighbor device dual-mode port" ::= { snFdpCacheEntry 15 } -- -- FDP Global Group -- snFdpGlobalRun OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The flag, whether the Foundry Discovery Protocol is currently running. FDP entries in snFdpCacheTable are deleted when FDP is disabled." DEFVAL { false } ::= { snFdpGlobal 1 } snFdpGlobalMessageInterval OBJECT-TYPE SYNTAX INTEGER (5..900) ACCESS read-write STATUS mandatory DESCRIPTION "The interval at which FDP messages are to be generated. The default value is 60 seconds." DEFVAL { 60 } ::= { snFdpGlobal 2 } snFdpGlobalHoldTime OBJECT-TYPE SYNTAX INTEGER (10..255) ACCESS read-write STATUS mandatory DESCRIPTION "The time for the receiving device holds FDP message. The default value is 180 seconds." DEFVAL { 180 } ::= { snFdpGlobal 3 } snFdpGlobalCdpRun OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-write STATUS mandatory DESCRIPTION "An indication of whether the Cisco Discovery Protocol is currently running. CDP entries in snFdpCacheTable are deleted when CDP is disabled." DEFVAL { false } ::= { snFdpGlobal 4 } -- -- FDP Cached Address Entry Table -- snFdpCachedAddressTable OBJECT-TYPE SYNTAX SEQUENCE OF FdpCachedAddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Cached address table from receiving FDP/CDP messages." ::= { snFdpCachedAddr 1 } snFdpCachedAddressEntry OBJECT-TYPE SYNTAX FdpCachedAddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry (conceptual row) in the snFdpCacheAddressTable, containing one cached address from FDP/CDP messages." INDEX { snFdpCachedAddrIfIndex, snFdpCachedAddrDeviceIndex, snFdpCachedAddrDeviceAddrEntryIndex } ::= { snFdpCachedAddressTable 1 } FdpCachedAddressEntry ::= SEQUENCE { snFdpCachedAddrIfIndex INTEGER, snFdpCachedAddrDeviceIndex INTEGER, snFdpCachedAddrDeviceAddrEntryIndex INTEGER, snFdpCachedAddrType INTEGER, snFdpCachedAddrValue OCTET STRING } snFdpCachedAddrIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The ifIndex value of the local interface." ::= { snFdpCachedAddressEntry 1 } snFdpCachedAddrDeviceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "A unique vlaue for each device from which FDP/CDP messages are being received." ::= { snFdpCachedAddressEntry 2 } snFdpCachedAddrDeviceAddrEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "A unique vlaue for address entry in device from which FDP/CDP messages are being received." ::= { snFdpCachedAddressEntry 3 } snFdpCachedAddrType OBJECT-TYPE SYNTAX INTEGER { ip(1), ipx(2), appletalk(3) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication of the type of address contained in the corresponding instance of snFdpCacheAddrValue." ::= { snFdpCachedAddressEntry 4 } snFdpCachedAddrValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The network-layer address of the device SNMP-agent as reported in the most recent FDP/CDP message in the following format: IP address: 4 octets, ip(1) IPX address: 10 octets, ipx(2) First 4-octet as the network number Second 6-octet as the host number Appletalk address: 3 octets, appletalk(3) First 2-octet as the network number Second 1-octet as the host number" ::= { snFdpCachedAddressEntry 5 } END