HP-SYSTEM-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Gauge32, IpAddress, NOTIFICATION-TYPE, Unsigned32, Integer32 FROM SNMPv2-SMI TEXTUAL-CONVENTION, TruthValue, DisplayString FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF hpProcurveCommon FROM HP-BASE-MIB; hpProcurveSystem MODULE-IDENTITY LAST-UPDATED "200502011455Z" ORGANIZATION "Hewlett Packard Company, ProCurve Networking Business" CONTACT-INFO "Hewlett Packard Company 8000 Foothills Blvd. Roseville, CA 95747" DESCRIPTION "This MIB module describes objects for basic management of devices in the HP Procurve product line." REVISION "200502011455Z" -- February 1, 2005 DESCRIPTION "Modified to reflect new OID hierarchy for HP J8162A XL Access Controller Module." ::= { hpProcurveCommon 1 } hpProcurveSysMib OBJECT IDENTIFIER ::= { hpProcurveSystem 1 } hpSystemMIBObjects OBJECT IDENTIFIER ::= { hpProcurveSystem 2 } hpConfig OBJECT IDENTIFIER ::= { hpSystemMIBObjects 1 } hpStatus OBJECT IDENTIFIER ::= { hpSystemMIBObjects 2 } hpNotificationsConfig OBJECT IDENTIFIER ::= { hpSystemMIBObjects 3 } -- System objects hpProductDescription OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Textual Description of the HW product" ::= { hpProcurveSysMib 1 } hpProductHWVersion OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "HW version of the product" ::= { hpProcurveSysMib 2 } hpProductSWVersion OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "SW version of the product" ::= { hpProcurveSysMib 3 } hpProductSerialNumber OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Serial Number of the product" ::= { hpProcurveSysMib 4 } hpProductLastChange OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Date and time of last configuration change" ::= { hpProcurveSysMib 5 } -- Environmental hpCpuTemperature OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Current temperature in degrees centigrade of the CPU." ::= { hpProcurveSysMib 6 } hpPowerSupplyTemperature OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Current temperature in degrees centigrade of the power supply." ::= { hpProcurveSysMib 7 } hpChassisTemperature OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Current temperature in degrees centigrade of the mother board. Note: this is not the ambient temperature of the box." ::= { hpProcurveSysMib 8 } hpFanStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF HpFanStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of operational status of all internal cooling fans." ::= { hpProcurveSysMib 9 } hpFanStatusEntry OBJECT-TYPE SYNTAX HpFanStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry in table of all internal cooling fans." INDEX { hpFanNumber } ::= { hpFanStatusTable 1 } HpFanStatusEntry ::= SEQUENCE { hpFanNumber INTEGER, hpFanOperational INTEGER, hpFanSpeed Integer32 } hpFanNumber OBJECT-TYPE SYNTAX INTEGER { cpu(1),power(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of cooling fan, numbered to represent what hardware the fan is supposed to be cooling." ::= { hpFanStatusEntry 1 } hpFanOperational OBJECT-TYPE SYNTAX INTEGER { true(1),false(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Operational status of a cooling fan." ::= { hpFanStatusEntry 2 } hpFanSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Speed of the fan in RPM." ::= { hpFanStatusEntry 3 } -- hpConfig group -- Additional information relating to the configuration of the HP ProCurve Networking -- Business Device hpName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "A textual string containing information about the device. For instance, this string reflects the setting of the HP J8162A XL Access Controller Module Name available on the Administrative Web based User Interface. If no HP J8162A XL Access Controller Module name is entered, this object contains a zero-length string." ::= { hpConfig 2 } hpSystemID OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The unique identifier for this device, as used by this system, or a master controlling system. For instance, an HP J8162A XL Access Controller Module would report the systemID used by the Access Control Server 740wl to uniquely identify this device." ::= { hpConfig 3 } hpState OBJECT-TYPE SYNTAX INTEGER { unknown(1), up(2), -- ready to pass packets down(3), primary(4), -- for Failover operation secondary(5) -- for Failover operation } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the device. A HP ProCurve Networking Business device can be configured for standalone operation, Failover (ie with a redundant peer), or for Distribution of configuration from a controlling central system to remote entities. unknown(1) - system Configuration status unknown up(2) - a standalone system is operational. down(3) - a system is not operational. primary(4) - system is running as the primary in a Failover peer configuration. secondary(5) - system is running as the backup in a Failover peer configuration." ::= { hpConfig 4 } hpDistributionType OBJECT-TYPE -- NOT CURRENTLY SUPPORTED - will report dummy values SYNTAX INTEGER { unknown(1), rightsPush(2) -- push central rights to remote systems. } MAX-ACCESS read-only STATUS current DESCRIPTION "The most recent distribution event type on a device. This object will change dynamically based on the most recently triggered distribution event. unknown(1) - the distribution event type none(2) - no distribution event has occurred rightsPush(3) - the central Access Control Server 740wl has triggered a rights push event to remote Access Control Server 740wls." ::= { hpConfig 5 } hpDistributionStatus OBJECT-TYPE -- NOT CURRENTLY SUPPORTED - will report dummy values SYNTAX INTEGER { unknown(1), succeeded(2), failed(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The most recent distribution event on a device. This object will change dynamically based on the most recently triggered distribution event. unknown(1) - the distribution event status unknown succeeded(2) - no distribution event has succeeded failed(3) - the distribution event failed for some reason." ::= { hpConfig 6 } hpIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The administratively assigned IP address associated with the device. This can be assigned statically on the device Console port, or configured via DHCP." ::= { hpConfig 7 } hpPeerIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The administratively assigned IP address associated with a redundant peer device, configured to work with this device for failover purposes. This can be assigned statically on the device Console port, or configured via DHCP. If the device does not support Failover configuration, or none has been configured, this object will report 0.0.0.0" ::= { hpConfig 8 } hpTechSupportEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object contains the current setting for the technical support access to the device. A value of true(1) indicates the Technical Support Access has been enabled. A value of false(2) indicates this access has been disabled. Note this object should only report true(2) if HP ProCurve Networking Business Technical Support staff have requested this access to the HP J8162A XL Access Controller Module for troubleshooting purposes." DEFVAL { false } ::= { hpConfig 9 } hpFailedAdminIpAddress OBJECT-TYPE -- NOT CURRENTLY SUPPORTED - will report dummy values SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address associated with the last failed authentication to the Administrative UI. If no Administrator had failed authentication, this object will report 0.0.0.0" ::= { hpConfig 10 } -- hpStatus hpNumAccessControllers OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of HP J8162A XL Access Controller Modules known to this system. If this system is an HP J8162A XL Access Controller Module, this value will be 1. Otherwise, this value will be the number of HP J8162A XL Access Controller Modules this system is connected to (i.e. An Access Control Server 740wl connects to multiple HP J8162A XL Access Controller Module's)." ::= { hpStatus 1 } hpNumClients OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of active authenticated or unauthenticated clients known to this system. If this device is an HP J8162A XL Access Controller Module, then this object reports the aggregated number of clients across all ports. If this device is a Access Control Server 740wl, it reports all Clients aggregated across all HP J8162A XL Access Controller Modules known to this system." ::= { hpStatus 2 } -- hpNotificationsConfig group -- Configure system level notifications hpFailoverNotificationEnabled OBJECT-TYPE -- NOT CURRENTLY SUPPORTED - will report dummy values SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object controls whether a hpFailover notification will be sent in the event of a failover occurrence between a primary and standby system. By default this object is set to false(2) for all systems." ::= { hpNotificationsConfig 1 } hpDistributionNotificationEnabled OBJECT-TYPE -- NOT CURRENTLY SUPPORTED - will report dummy values SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object controls whether a hpDistribution notification will be sent in the event of a distribution event between a central and remote systems. By default this object is set to false(2) for all systems." DEFVAL { false } ::= { hpNotificationsConfig 2 } hpAdminAuthFailureNotificationEnabled OBJECT-TYPE -- NOT CURRENTLY SUPPORTED - will report dummy values SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object controls whether a hpAdminAuthFailure notification will be sent in the event of a failed authentication attempt at the administrator login." DEFVAL { false } ::= { hpNotificationsConfig 3 } -- Traps hpSystemTraps OBJECT IDENTIFIER ::= { hpProcurveSystem 0 } fanDown NOTIFICATION-TYPE OBJECTS { hpFanNumber } STATUS current DESCRIPTION "A fanDown trap signifies that hpFanOperational has detected an event where the fan is not operating." ::= { hpSystemTraps 1 } fanUp NOTIFICATION-TYPE OBJECTS { hpFanNumber } STATUS current DESCRIPTION "A fanUp trap signifies that hpFanOperational has detected an event where the fan is now operating." ::= { hpSystemTraps 2 } temperatureAlarm NOTIFICATION-TYPE OBJECTS { hpCpuTemperature } STATUS current DESCRIPTION "A temperatureAlarm signifies that the SNMP entity, acting in an agent role, has detected that the hpCpuTemperature has a value that exceeds acceptable tolerances (i.e. it is too hot or too cold)." ::= { hpSystemTraps 3 } hpFailover NOTIFICATION-TYPE OBJECTS { hpIpAddress} STATUS current DESCRIPTION "A hpFailover signifies that the SNMP entity, acting in an agent role, has detected that the standby system in a primary, redundant operation has become the primary system. This notification will only be sent by what was formerly the standby system." ::= { hpSystemTraps 4 } hpDistributionEvent NOTIFICATION-TYPE -- NOT CURRENTLY SUPPORTED OBJECTS { hpDistributionType, hpDistributionStatus} STATUS current DESCRIPTION "A hpDistributionEvent signifies that the SNMP entity, acting in an agent role, has detected that the central entity in a distributed system has triggered a distribution event of hpDistributionType." ::= { hpSystemTraps 5 } hpAdminAuthFailure NOTIFICATION-TYPE -- NOT CURRENTLY SUPPORTED OBJECTS { hpFailedAdminIpAddress} STATUS current DESCRIPTION "A hpAdminAuthFailure signifies that the SNMP entity, acting in an agent role, has detected that someone at the address reported by hpAdminIpAddress has failed to authenticate to the device via the administrative interface." ::= { hpSystemTraps 6 } -- conformance information hpSystemMIBConformance OBJECT IDENTIFIER ::= { hpProcurveSystem 3 } hpCompliances OBJECT IDENTIFIER ::= { hpSystemMIBConformance 1 } hpGroups OBJECT IDENTIFIER ::= { hpSystemMIBConformance 2 } hpSystemMIBCompliance1 MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for entities which implement the HP-SYSTEM-MIB." MODULE -- this module MANDATORY-GROUPS { hpSystemGroup, hpConfigGroup } GROUP hpEnvGroup DESCRIPTION "The hpEnvGroup is optional for all entities." GROUP hpStatusGroup DESCRIPTION "The hpStatusGroup is optional for all entities." GROUP hpNotificationsConfigGroup DESCRIPTION "The hpNotificationsConfigGroup is optional for all entities." GROUP hpNotificationsGroup DESCRIPTION "The hpNotificationsGroup is optional for all entities." OBJECT hpName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT hpIpAddress MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT hpTechSupportEnabled MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT hpFailoverNotificationEnabled MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT hpDistributionNotificationEnabled MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT hpAdminAuthFailureNotificationEnabled MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { hpCompliances 1 } -- units of conformance hpSystemGroup OBJECT-GROUP OBJECTS { hpProductDescription, hpProductHWVersion, hpProductSWVersion, hpProductSerialNumber, hpProductLastChange } STATUS current DESCRIPTION "A collection of objects providing system information applicable to all devices." ::= { hpGroups 1 } hpEnvGroup OBJECT-GROUP OBJECTS { hpCpuTemperature, hpPowerSupplyTemperature, hpChassisTemperature, hpFanNumber, hpFanOperational, hpFanSpeed } STATUS current DESCRIPTION "A collection of objects providing environmental information applicable to all devices." ::= { hpGroups 2 } hpConfigGroup OBJECT-GROUP OBJECTS { hpName, hpSystemID, hpState, hpIpAddress, hpPeerIpAddress, hpTechSupportEnabled, hpDistributionType, hpDistributionStatus, hpFailedAdminIpAddress } STATUS current DESCRIPTION "A collection of objects providing configuration information applicable to all devices." ::= { hpGroups 3 } hpStatusGroup OBJECT-GROUP OBJECTS { hpNumAccessControllers, hpNumClients } STATUS current DESCRIPTION "A collection of objects providing statistics applicable to all HP J8162A XL Access Controller Module like devices." ::= { hpGroups 4 } hpNotificationsConfigGroup OBJECT-GROUP OBJECTS { hpFailoverNotificationEnabled, hpDistributionNotificationEnabled, hpAdminAuthFailureNotificationEnabled } STATUS current DESCRIPTION "A collection of objects providing notification configuration information applicable to all devices." ::= { hpGroups 5 } hpNotificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { fanDown, fanUp, temperatureAlarm, hpFailover, hpDistributionEvent, hpAdminAuthFailure } STATUS current DESCRIPTION "notifications for primary failover, and authorization failures, applicable to all devices." ::= { hpGroups 6 } END