-- ================================================================= -- Copyright (C) 2017 by HUAWEI TECHNOLOGIES. All rights reserved. -- -- Description: Huawei Ethernet ND MIB -- Reference: HUAWEI Enterprise MIB -- Version: V1.03 -- History: -- gaoning , 2014-06-27, add nodes for ND. -- ================================================================= HUAWEI-ND-MIB DEFINITIONS ::= BEGIN IMPORTS hwDatacomm FROM HUAWEI-MIB OBJECT-TYPE, MODULE-IDENTITY, OBJECT-TYPE, IpAddress, Counter32, Integer32, Unsigned32, NOTIFICATION-TYPE FROM SNMPv2-SMI PhysAddress, DisplayString, RowStatus FROM SNMPv2-TC NOTIFICATION-GROUP, OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF ifIndex, ifName, InterfaceIndex,InterfaceIndexOrZero,ifAdminStatus,ifOperStatus,ifDescr FROM IF-MIB PhysicalIndex, entPhysicalIndex, entPhysicalName FROM ENTITY-MIB; hwNDMIB MODULE-IDENTITY LAST-UPDATED "201708171600Z" ORGANIZATION "Huawei Technologies Co.,Ltd." CONTACT-INFO "Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: http://www.huawei.com Email: support@huawei.com " DESCRIPTION "Please provide the descritpion." REVISION "201708171600Z" DESCRIPTION "V1.02, Modify description of hwNDSlotThresholdExceedValue and hwNDIntfThresholdExceedValue at 2017-07-04" REVISION "201707041600Z" DESCRIPTION "V1.02, Modify description of hwSlotNDThresholdExceedAlarm at 2017-07-04." REVISION "201407011600Z" DESCRIPTION "V1.01, initial version." REVISION "201008111600Z" DESCRIPTION "V1.00, initial version." ::= { hwDatacomm 332 } hwNDObjects OBJECT IDENTIFIER ::= { hwNDMIB 1 } -- ================================================================= -- 1th slot nd entries alarm -- ================================================================= hwNDStatisticsPerSlotTable OBJECT-TYPE SYNTAX SEQUENCE OF HwNDStatisticsPerSlotEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the threshold of the alarm generated in slot." ::= { hwNDObjects 1 } hwNDStatisticsPerSlotEntry OBJECT-TYPE SYNTAX HwNDStatisticsPerSlotEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the threshold of the alarm generated in slot." INDEX {hwNDSlotPhysicalIndex} ::= { hwNDStatisticsPerSlotTable 1 } HwNDStatisticsPerSlotEntry ::= SEQUENCE { hwNDSlotPhysicalIndex Unsigned32 , hwNDSlotThresholdExceedValue Unsigned32 , hwNDSlotThresholdResumeValue Unsigned32 , hwNDSlotDynamicNumber Unsigned32 , hwNDSlotStaticNumber Unsigned32 , hwNDSlotTotalNumber Unsigned32 } hwNDSlotPhysicalIndex OBJECT-TYPE SYNTAX Unsigned32(0..4294967294) MAX-ACCESS read-only STATUS current DESCRIPTION "The slot of alarm generated." ::= { hwNDStatisticsPerSlotEntry 1 } hwNDSlotThresholdExceedValue OBJECT-TYPE SYNTAX Unsigned32(1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates an ND entry alarm threshold on a board. An ND entry threshold-exceeding alarm is generated when the ratio of the number of ND entries on a board to the maximum number allowed is greater than or equal to the alarm threshold." ::= { hwNDStatisticsPerSlotEntry 2 } hwNDSlotThresholdResumeValue OBJECT-TYPE SYNTAX Unsigned32(1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates an ND entry clear alarm threshold on a board. An ND entry clear alarm is generated when the ratio of the number of ND entries on a board to the maximum number allowed is less than or equal to the clear alarm threshold." ::= { hwNDStatisticsPerSlotEntry 3 } hwNDSlotDynamicNumber OBJECT-TYPE SYNTAX Unsigned32(0..4294967294) MAX-ACCESS read-only STATUS current DESCRIPTION "Current dynamic ND entries in slot." ::= { hwNDStatisticsPerSlotEntry 4 } hwNDSlotStaticNumber OBJECT-TYPE SYNTAX Unsigned32(0..4294967294) MAX-ACCESS read-only STATUS current DESCRIPTION "Current static ND entries in slot." ::= { hwNDStatisticsPerSlotEntry 5 } hwNDSlotTotalNumber OBJECT-TYPE SYNTAX Unsigned32(0..4294967294) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum ND entries number for slot." ::= { hwNDStatisticsPerSlotEntry 6 } -- ================================================================= -- 2th interface nd entries alarm -- ================================================================= hwNDStatisticsPerIfTable OBJECT-TYPE SYNTAX SEQUENCE OF HwNDStatisticsPerIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the threshold of the alarm generated in interface." ::= { hwNDObjects 2 } hwNDStatisticsPerIfEntry OBJECT-TYPE SYNTAX HwNDStatisticsPerIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the threshold of the alarm generated in interface." INDEX {hwNDIntfIndex} ::= { hwNDStatisticsPerIfTable 1 } HwNDStatisticsPerIfEntry ::= SEQUENCE { hwNDIntfIndex Unsigned32 , hwNDIntfThresholdExceedValue Unsigned32 , hwNDIntfThresholdResumeValue Unsigned32 , hwNDIntfDynamicNumber Unsigned32 , hwNDIntfStaticNumber Unsigned32 , hwNDIntfTotalNumber Unsigned32 } hwNDIntfIndex OBJECT-TYPE SYNTAX Unsigned32(0..4294967294) MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of alarm generated." ::= { hwNDStatisticsPerIfEntry 1 } hwNDIntfThresholdExceedValue OBJECT-TYPE SYNTAX Unsigned32(1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates an ND entry alarm threshold on an interface. An ND entry threshold-exceeding alarm is generated when the ratio of the number of ND entries on an interface to the maximum number allowed is greater than or equal to the alarm threshold." ::= { hwNDStatisticsPerIfEntry 2 } hwNDIntfThresholdResumeValue OBJECT-TYPE SYNTAX Unsigned32(1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates an ND entry clear alarm threshold on an interface. An ND entry clear alarm is generated when the ratio of the number of ND entries on an interface to the maximum number allowed is less than or equal to the clear alarm threshold." ::= { hwNDStatisticsPerIfEntry 3 } hwNDIntfDynamicNumber OBJECT-TYPE SYNTAX Unsigned32(0..4294967294) MAX-ACCESS read-only STATUS current DESCRIPTION "Current dynamic ND entries in interface." ::= { hwNDStatisticsPerIfEntry 4 } hwNDIntfStaticNumber OBJECT-TYPE SYNTAX Unsigned32(0..4294967294) MAX-ACCESS read-only STATUS current DESCRIPTION "Current static ND entries in interface." ::= { hwNDStatisticsPerIfEntry 5 } hwNDIntfTotalNumber OBJECT-TYPE SYNTAX Unsigned32(0..4294967294) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum ND entries number for interface." ::= { hwNDStatisticsPerIfEntry 6 } -- Notifications(trap) Definitions hwNDNotifications OBJECT IDENTIFIER ::= { hwNDMIB 2 } hwSlotNDThresholdExceedAlarm NOTIFICATION-TYPE OBJECTS { entPhysicalName, hwNDSlotThresholdExceedValue,hwNDSlotDynamicNumber,hwNDSlotStaticNumber } STATUS current DESCRIPTION "This object indicates that an alarm is generated when the ratio of the number of ND entries on a board to the maximum number of ND entries supported on the board is greater than or equal to the 80% threshold." ::= { hwNDNotifications 1 } hwSlotNDThresholdResumeAlarm NOTIFICATION-TYPE OBJECTS { entPhysicalName,hwNDSlotThresholdResumeValue,hwNDSlotDynamicNumber,hwNDSlotStaticNumber } STATUS current DESCRIPTION "This object indicates that a clear alarm is generated when the ratio of the number of ND entries on a board to the maximum number of ND entries supported on the board is less than or equal to the 70% threshold." ::= { hwNDNotifications 2 } hwInterfaceNDThresholdExceedAlarm NOTIFICATION-TYPE OBJECTS { entPhysicalName,ifDescr,hwNDIntfThresholdExceedValue,hwNDIntfDynamicNumber,hwNDIntfStaticNumber } STATUS current DESCRIPTION "This object indicates that an alarm is generated when the ratio of the number of ND entries on an interface to the maximum number of ND entries supported on the interface is greater than or equal to the 80% threshold." ::= { hwNDNotifications 3 } hwInterfaceNDThresholdResumeAlarm NOTIFICATION-TYPE OBJECTS { entPhysicalName,ifDescr,hwNDIntfThresholdResumeValue,hwNDIntfDynamicNumber,hwNDIntfStaticNumber } STATUS current DESCRIPTION "This object indicates that a clear alarm is generated when the ratio of the number of ND entries on an interface to the maximum number of ND entries supported on the interface is less than or equal to the 70% threshold." ::= { hwNDNotifications 4 } -- Conformance information hwNDConformance OBJECT IDENTIFIER ::= { hwNDMIB 3 } hwNDGroups OBJECT IDENTIFIER ::= { hwNDConformance 1 } hwNDCompliances OBJECT IDENTIFIER ::= { hwNDConformance 2 } hwNDSlotGroup OBJECT-GROUP OBJECTS { hwNDSlotPhysicalIndex, hwNDSlotThresholdExceedValue, hwNDSlotThresholdResumeValue, hwNDSlotDynamicNumber, hwNDSlotStaticNumber, hwNDSlotTotalNumber } STATUS current DESCRIPTION "A collection of objects for ND threshold alarm in interface." ::= { hwNDGroups 1 } hwNDIntfGroup OBJECT-GROUP OBJECTS { hwNDIntfIndex, hwNDIntfThresholdExceedValue, hwNDIntfThresholdResumeValue, hwNDIntfDynamicNumber, hwNDIntfStaticNumber, hwNDIntfTotalNumber } STATUS current DESCRIPTION "A collection of objects for ND threshold alarm in slot." ::= { hwNDGroups 2 } hwNDNotificationsGroup NOTIFICATION-GROUP NOTIFICATIONS{ hwSlotNDThresholdExceedAlarm, hwSlotNDThresholdResumeAlarm, hwInterfaceNDThresholdExceedAlarm, hwInterfaceNDThresholdResumeAlarm} STATUS current DESCRIPTION "notification Group." ::= { hwNDGroups 3 } hwNDCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for ND thre." MODULE MANDATORY-GROUPS { hwNDSlotGroup, hwNDIntfGroup } ::= { hwNDCompliances 1 } -- ================================================================= -- units of conformance -- ================================================================= END