-- ================================================================= -- Copyright (C) 2003 by HUAWEI TECHNOLOGIES. All rights reserved -- -- Description: HUAWEI-SLOG-EUDM-MIB -- Reference: -- Version: V1.0 -- History: -- yangyinzhu,2003-03-18, -- ================================================================= HUAWEI-SLOG-EUDM-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-GROUP FROM SNMPv2-CONF IpAddress, Integer32, OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI TruthValue, TEXTUAL-CONVENTION FROM SNMPv2-TC hwDatacomm FROM HUAWEI-MIB; hwSLOGEudm MODULE-IDENTITY LAST-UPDATED "200304081633Z" -- April 08, 2003 at 16:33 GMT ORGANIZATION "Huawei Technologies co.,Ltd." CONTACT-INFO " R&D BeiJing, Huawei Technologies co.,Ltd. Huawei Bld.,NO.3 Xinxi Rd., Shang-Di Information Industry Base, Hai-Dian District Beijing P.R. China Zip:100085 Http://www.huawei.com E-mail:support@huawei.com " DESCRIPTION " V1.00 The HUAWEI-SLOG-EUDM-MIB contains objects to manage the security log for firewall product. " ::= { hwSLOG 2 } -- -- Textual conventions -- FlowLogType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Description." SYNTAX INTEGER { flowLogSysLog(1), flowLogExport(2) } -- -- Node definitions -- -- 1.3.6.1.4.1.2011.5.25.16 hwSLOG OBJECT IDENTIFIER ::= { hwDatacomm 16 } -- 1.3.6.1.4.1.2011.5.25.16.2.1 hwSLogEudmGlobalCfg OBJECT IDENTIFIER ::= { hwSLOGEudm 1 } -- 1.3.6.1.4.1.2011.5.25.16.2.1.1 hwSLogEudmAttackLogInterval OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " The interval for sending log of attack event, the unit is second." ::= { hwSLogEudmGlobalCfg 1 } -- 1.3.6.1.4.1.2011.5.25.16.2.1.2 hwSLogEudmFlowLogInterval OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The interval for sending flow log, the unit is second." ::= { hwSLogEudmGlobalCfg 2 } -- 1.3.6.1.4.1.2011.5.25.16.2.1.3 hwSLogEudmStreamLogInterval OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The interval for sending log of statistics, the unit is second." ::= { hwSLogEudmGlobalCfg 3 } -- 1.3.6.1.4.1.2011.5.25.16.2.1.4 hwSLogEudmFlowLogMode OBJECT-TYPE SYNTAX FlowLogType MAX-ACCESS read-write STATUS current DESCRIPTION "The sending mode of flow log, can be SysLog or Export." DEFVAL { flowLogSysLog } ::= { hwSLogEudmGlobalCfg 4 } -- 1.3.6.1.4.1.2011.5.25.16.2.1.5 hwSLogEudmServerIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of log server." DEFVAL { 00000000 } ::= { hwSLogEudmGlobalCfg 5 } -- 1.3.6.1.4.1.2011.5.25.16.2.1.6 hwSLogEudmServerPort OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The port of log server." ::= { hwSLogEudmGlobalCfg 6 } -- 1.3.6.1.4.1.2011.5.25.16.2.2 hwSLogInterZoneEnableCfg OBJECT IDENTIFIER ::= { hwSLOGEudm 2 } -- 1.3.6.1.4.1.2011.5.25.16.2.2.1 hwSLogEudmFlowLogEnableTable OBJECT-TYPE SYNTAX SEQUENCE OF HwSLogEudmFlowLogEnableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description" ::= { hwSLogInterZoneEnableCfg 1 } -- 1.3.6.1.4.1.2011.5.25.16.2.2.1.1 hwSLogEudmFlowLogEnableEntry OBJECT-TYPE SYNTAX HwSLogEudmFlowLogEnableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each inter-zone must have an entry" INDEX { hwSLogFlowEnableZoneID1, hwSLogFlowEnableZoneID2 } ::= { hwSLogEudmFlowLogEnableTable 1 } HwSLogEudmFlowLogEnableEntry ::= SEQUENCE { hwSLogFlowEnableZoneID1 Integer32, hwSLogFlowEnableZoneID2 Integer32, hwSLogEudmFlowEnableFlag TruthValue, hwSLogEudmEnableHostAcl Integer32 } -- 1.3.6.1.4.1.2011.5.25.16.2.2.1.1.1 hwSLogFlowEnableZoneID1 OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ID of first zone that compose the inter-zone." ::= { hwSLogEudmFlowLogEnableEntry 1 } -- 1.3.6.1.4.1.2011.5.25.16.2.2.1.1.2 hwSLogFlowEnableZoneID2 OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ID of second zone that compose the inter-zone." ::= { hwSLogEudmFlowLogEnableEntry 2 } -- 1.3.6.1.4.1.2011.5.25.16.2.2.1.1.3 hwSLogEudmFlowEnableFlag OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "The status indicate whether the security log is enabled in this interzone." ::= { hwSLogEudmFlowLogEnableEntry 3 } -- 1.3.6.1.4.1.2011.5.25.16.2.2.1.1.4 hwSLogEudmEnableHostAcl OBJECT-TYPE SYNTAX Integer32 (0 | 2000..3999) MAX-ACCESS read-write STATUS current DESCRIPTION "The acl number indicate the data flow which will be logged." ::= { hwSLogEudmFlowLogEnableEntry 4 } -- 1.3.6.1.4.1.2011.5.25.16.2.3 hwSLOGEudmConformance OBJECT IDENTIFIER ::= { hwSLOGEudm 3 } -- 1.3.6.1.4.1.2011.5.25.16.2.3.1 hwSLOGEudmCompliance OBJECT IDENTIFIER ::= { hwSLOGEudmConformance 1 } -- 1.3.6.1.4.1.2011.5.25.16.2.3.2 hwSLOGEudmMibGroups OBJECT IDENTIFIER ::= { hwSLOGEudmConformance 2 } -- 1.3.6.1.4.1.2011.5.25.16.2.3.2.1 hwSLOGEudmGlobalCfgGroup OBJECT-GROUP OBJECTS { hwSLogEudmAttackLogInterval, hwSLogEudmStreamLogInterval, hwSLogEudmFlowLogMode, hwSLogEudmFlowLogInterval, hwSLogEudmServerIP, hwSLogEudmServerPort } STATUS current DESCRIPTION "Description." ::= { hwSLOGEudmMibGroups 1 } -- 1.3.6.1.4.1.2011.5.25.16.2.3.2.2 hwSLOGEudmFlowLogEnableGroup OBJECT-GROUP OBJECTS { hwSLogEudmFlowEnableFlag, hwSLogEudmEnableHostAcl } STATUS current DESCRIPTION "Description." ::= { hwSLOGEudmMibGroups 2 } END -- -- HUAWEI-SLOG-EUDM-MIB.mib --