-- ============================================================================ -- Copyright (C)2011 by HUAWEI TECHNOLOGIES. All rights reserved. -- Description: The MIB module defines MIB objects which provide -- device management NMS interfaces. -- Reference: -- Version: V1.18 -- ============================================================================ HWMUSA-DEV-MIB DEFINITIONS ::= BEGIN IMPORTS hwFrameIndex, hwSlotIndex FROM HUAWEI-DEVICE-MIB hwProducts FROM HUAWEI-MIB HWPCBType,HWFrameType FROM HUAWEI-TC-MIB Integer32, OBJECT-TYPE,Unsigned32,MODULE-IDENTITY FROM SNMPv2-SMI RowStatus, DateAndTime FROM SNMPv2-TC; musa MODULE-IDENTITY LAST-UPDATED "201201180000Z" ORGANIZATION "Huawei Technologies Co.,Ltd." CONTACT-INFO "Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: http://www.huawei.com Email: support@huawei.com " DESCRIPTION " The MIB module defines MIB objects which provide device management NMS interfaces. " -- Revision history REVISION "201203310000Z" DESCRIPTION "V1.18, Added enumerated value 0x02000173 to hwMusaBoardLatestResetCause's value list." REVISION "201201170000Z" DESCRIPTION "V1.17, Added hwMusaFramePowerSupplyTable node." REVISION "201111180000Z" DESCRIPTION "V1.16, Added enumerated value dcAndRemote(8) and acAndDc(9) to hwMusaFramePowerMode's value list." REVISION "201107080000Z" DESCRIPTION "V1.15, Time and type of last Board reset on OLT devices." REVISION "201101120000Z" DESCRIPTION "V1.14, Added enumerated value acRemote(7) to hwMusaFramePowerMode's value list.." REVISION "201011100000Z" DESCRIPTION "V1.13, Modified the description of hwMusaSlotConfExtTable, hwMusaSlotConfExtEntry, hwMusaBoardTemperature, hwMusaSlotAverageConfTable, hwMusaSlotAverageConfEntry, hwMusaBoardStatisticTime, hwXPONBoardParaTable, hwXPONBoardParaEntry, hwBroadBandFrameOperTable, hwBroadBandFrameOperEntry and hwIasConfigChangeEntry." REVISION "201008190000Z" DESCRIPTION "V1.12, Modified the description of the objects in this MIB file for MIB standardization." REVISION "201003240000Z" DESCRIPTION "V1.11, Modified this MIB for clearing simple tester errors and warnings." REVISION "201002220000Z" DESCRIPTION "V1.10, Added enumerated value pd(6) to hwMusaFramePowerMode's value list." REVISION "201002100000Z" DESCRIPTION "V1.09, Modified MIB descriptions." REVISION "201002030000Z" DESCRIPTION "V1.08, Cleared compile warnings." REVISION "200907220000Z" DESCRIPTION "V1.07, Added enumerated value linePowered(5) to hwMusaFramePowerMode's value list." REVISION "200907200000Z" DESCRIPTION "V1.06, Added hwMusaFramePower, hwMusaBoardPower, and hwMusaBoardActivedPortNum." REVISION "200611270000Z" DESCRIPTION "V1.00, Initial version." ::= { hwProducts 6 } ias OBJECT IDENTIFIER ::= { musa 7 } hwIasDev OBJECT IDENTIFIER ::= { ias 1 } hwMusaSlotConf OBJECT IDENTIFIER ::= { hwIasDev 1 } hwMusaFrameExtTable OBJECT-TYPE SYNTAX SEQUENCE OF HwMusaFrameExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Frame description extended table.The table describes the bandwidth of the frame, and also contains the EMU and slot information of the frame. The index of this table is hwFrameIndex. It is the frame ID. " ::= { hwMusaSlotConf 1 } hwMusaFrameExtEntry OBJECT-TYPE SYNTAX HwMusaFrameExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Frame description extended table.The table describes the bandwidth of the frame, and also contains the EMU and slot information of the frame. The index of this entry is hwFrameIndex. It is the frame ID. " INDEX { hwFrameIndex } ::= { hwMusaFrameExtTable 1 } HwMusaFrameExtEntry ::= SEQUENCE { hwMusaFrameLimtBandWidth Integer32, hwMusaFrameDistBandWidth Integer32, hwMusaFrameTestGroupID Integer32, hwMusaFrameEmuId1 Integer32, hwMusaFrameEmuId2 Integer32, hwMusaFrameEmuId3 Integer32, hwMusaFrameEmuId4 Integer32, hwMusaFrameEmuId5 Integer32, hwMusaFrameSlotConnection OCTET STRING, hwMusaFramePowerMode INTEGER, hwMusaFramePower Integer32 } hwMusaFrameLimtBandWidth OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Frame limit bandwidth,the maximum bandwidth of the frame. Unit: K. It is used in debug mode. 1G = 1000M. " ::= { hwMusaFrameExtEntry 1 } hwMusaFrameDistBandWidth OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Frame distributed bandwidth. Unit: K. It is used in debug mode. 1G = 1000M. " ::= { hwMusaFrameExtEntry 2 } hwMusaFrameTestGroupID OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION " This node is not supported. " ::= { hwMusaFrameExtEntry 3 } hwMusaFrameEmuId1 OBJECT-TYPE SYNTAX Integer32 (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION " This node is not supported. " ::= { hwMusaFrameExtEntry 4 } hwMusaFrameEmuId2 OBJECT-TYPE SYNTAX Integer32 (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION " This node is not supported. " ::= { hwMusaFrameExtEntry 5 } hwMusaFrameEmuId3 OBJECT-TYPE SYNTAX Integer32 (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION " This node is not supported. " ::= { hwMusaFrameExtEntry 6 } hwMusaFrameEmuId4 OBJECT-TYPE SYNTAX Integer32 (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION " This node is not supported. " ::= { hwMusaFrameExtEntry 7 } hwMusaFrameEmuId5 OBJECT-TYPE SYNTAX Integer32 (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION " This node is not supported. " ::= { hwMusaFrameExtEntry 8 } hwMusaFrameSlotConnection OBJECT-TYPE SYNTAX OCTET STRING (SIZE (255)) MAX-ACCESS read-only STATUS current DESCRIPTION " This node is not supported. " ::= { hwMusaFrameExtEntry 9 } hwMusaFramePowerMode OBJECT-TYPE SYNTAX INTEGER { localac(1), localdc(2), localacBackuppower(3), backuppower(4), remotedc(5), pd(6), remoteac(7), localdcAndRemotedc(8), localacAndlocaldc(9) } MAX-ACCESS read-only STATUS current DESCRIPTION " Frame power supply mode. Options: 1.localac(1) -local 220V AC power supply 2.localdc(2) -local DC power supply 3.localacBackuppower(3) -AC power and backuppower supply 4.backuppower(4) -accumulator supply 5.remotedc(5) -remote line +/-190V high voltage power supply of DC 6.pd(6) -powered device supply 7.remoteac(7) -remote 60V AC power supply 8.localdcAndRemotedc(8) -DC power and Remote power are provided at the same time 9.localacAndlocaldc(9) -DC power and AC power are provided at the same time " ::= { hwMusaFrameExtEntry 10 } hwMusaFramePower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The total power of the frame. It includes the power of service boards, active control board, standby control board, interface boards, and environment monitoring boards. Unit: watt. " ::= { hwMusaFrameExtEntry 11 } hwMusaSlotConfExtTable OBJECT-TYPE SYNTAX SEQUENCE OF HwMusaSlotConfExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Board description extended table. The tabel is used for describing the extended information about all boards in each slot of the shelf. The indexes of this table are hwFrameIndex and hwSlotIndex. " ::= { hwMusaSlotConf 2 } hwMusaSlotConfExtEntry OBJECT-TYPE SYNTAX HwMusaSlotConfExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Board description extended table. The tabel is used for describing the extended information about all boards in each slot of the shelf. The indexes of this entry are hwFrameIndex and hwSlotIndex. " INDEX { hwFrameIndex, hwSlotIndex } ::= { hwMusaSlotConfExtTable 1 } HwMusaSlotConfExtEntry ::= SEQUENCE { hwMusaBoardLimitBandWidthUp Integer32, hwMusaBoardLimitBandWidthDown Integer32, hwMusaBoardHasBandWidthUp Integer32, hwMusaBoardHasBandWidthDown Integer32, hwMusaBoardCpuRate Integer32, hwMusaBoardRamUseRate Integer32, hwMusaBoardSlotDesc OCTET STRING, hwMusaBoardOnlineState INTEGER, hwMusaServiceChannelBufferRate Integer32, hwMusaBoardTemperature Integer32, hwMusaBoardPower Integer32, hwMusaBoardActivedPortNum Integer32, hwMusaBoardLatestResetTime DateAndTime, hwMusaBoardLatestResetCause Integer32 } hwMusaBoardLimitBandWidthUp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " This node is not supported. " ::= { hwMusaSlotConfExtEntry 1 } hwMusaBoardLimitBandWidthDown OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " This node is not supported. " ::= { hwMusaSlotConfExtEntry 2 } hwMusaBoardHasBandWidthUp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " This node is not supported. " ::= { hwMusaSlotConfExtEntry 3 } hwMusaBoardHasBandWidthDown OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " This node is not supported. " ::= { hwMusaSlotConfExtEntry 4 } hwMusaBoardCpuRate OBJECT-TYPE SYNTAX Integer32 (-1 | 0..100) MAX-ACCESS read-only STATUS current DESCRIPTION " Active and standby control board CPU usage. It does not support RSP, PV8, BAS, or other boards. -1 indicates that the device cannot get the value, e.g. the board does not support this operation, or the board state is abnormal. " ::= { hwMusaSlotConfExtEntry 5 } hwMusaBoardRamUseRate OBJECT-TYPE SYNTAX Integer32 ( -1 | 0..100) MAX-ACCESS read-only STATUS current DESCRIPTION " Active and standby control board RAM usage. It does not support RSP, PV8, BAS, AIC, or other boards. -1 indicates that the device cannot get the value, e.g. the board does not support this operation, or the board state is abnormal. " ::= { hwMusaSlotConfExtEntry 6 } hwMusaBoardSlotDesc OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION " Slot information description. It describes the name of the slot. " ::= { hwMusaSlotConfExtEntry 7 } hwMusaBoardOnlineState OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2), unmanageable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " Board online state. Options: 1.online(1) -board is online 2.offline(2) -board is offline 3.unmanageable(3) -board is faulty " ::= { hwMusaSlotConfExtEntry 8 } hwMusaServiceChannelBufferRate OBJECT-TYPE SYNTAX Integer32 (-1 | 0..100) MAX-ACCESS read-only STATUS current DESCRIPTION " Service channel buffer usage. It only supports the xDSL service board on the MA5600 and the MA5600T product. -1 indicates that the device cannot get the value, e.g. the board does not support this operation, or the board state is abnormal. " ::= { hwMusaSlotConfExtEntry 9 } hwMusaBoardTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Board temperature.The value 0X7FFFFFF indicates invalid temperature. It only supports the H801SCUB and H801SCUL boards. " ::= { hwMusaSlotConfExtEntry 10 } hwMusaBoardPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The power of the board. Unit: watt. " ::= { hwMusaSlotConfExtEntry 11 } hwMusaBoardActivedPortNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The number of activated ports on one board. " ::= { hwMusaSlotConfExtEntry 12 } hwMusaBoardLatestResetTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION " The latest reset time of the board. " ::= { hwMusaSlotConfExtEntry 13 } hwMusaBoardLatestResetCause OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The latest reset cause of the board. 0x00000000 - There is no reset record of the board. 0x02000000 - The communication with the control board is abnormal. 0x02000165 - COM user delivers board reset command. 0x02000167 - NMS user delivers board reset command. 0x02000169 - Telnet user delivers board reset command. 0x0200016b - User add board manually. 0x020000a1 - The board temperature is too high, which causes the shutdown of the board. 0x02000173 - The board resets because the working mode is changed. 0x02000181 - The service board is automatically shut down when it is not configured with any service. 0x02000182 - The service board is automatically shut down when the mains supply is interrupted. 0x020001b5 - The board is loosened or is removed forcibly. 0x0700000a - The active/standby switchover command is manually delivered. " ::= { hwMusaSlotConfExtEntry 14 } hwMusaSlotAverageConfTable OBJECT-TYPE SYNTAX SEQUENCE OF HwMusaSlotAverageConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The indexes of this table are hwFrameIndex and hwSlotIndex. This table is not supported. " ::= { hwMusaSlotConf 3 } hwMusaSlotAverageConfEntry OBJECT-TYPE SYNTAX HwMusaSlotAverageConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The indexes of this entry are hwFrameIndex and hwSlotIndex. This table is not supported. " INDEX { hwFrameIndex, hwSlotIndex, hwMusaBoardStatisticTime } ::= { hwMusaSlotAverageConfTable 1 } HwMusaSlotAverageConfEntry ::= SEQUENCE { hwMusaBoardStatisticTime INTEGER, hwMusaBoardCpuAverageRate Integer32 } hwMusaBoardStatisticTime OBJECT-TYPE SYNTAX INTEGER { five-seconds(1), one-minute(2), ten-minutes(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " This node is not supported. Options: 1. five-seconds(1) -five seconds 2. one-minute(2) -one minute 3. ten-minutes(3) -ten minutes " ::= { hwMusaSlotAverageConfEntry 1 } hwMusaBoardCpuAverageRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " This node is not supported. " ::= { hwMusaSlotAverageConfEntry 2 } hwXPONBoardParaTable OBJECT-TYPE SYNTAX SEQUENCE OF HwXPONBoardParaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The indexes of this table are hwFrameIndex and hwSlotIndex. This table is not supported. " ::= { hwMusaSlotConf 4 } hwXPONBoardParaEntry OBJECT-TYPE SYNTAX HwXPONBoardParaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The indexes of this entry are hwFrameIndex and hwSlotIndex. This table is not supported. " INDEX { hwXPONBoardParaFrameIndex, hwXPONBoardParaSlotIndex } ::= { hwXPONBoardParaTable 1 } HwXPONBoardParaEntry ::= SEQUENCE { hwXPONBoardParaFrameIndex Integer32, hwXPONBoardParaSlotIndex Integer32, hwXPONBoardSN OCTET STRING, hwXPONBoardPassWord OCTET STRING, hwXPONBoardMacAddr OCTET STRING } hwXPONBoardParaFrameIndex OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION " This node is not supported. " ::= { hwXPONBoardParaEntry 1 } hwXPONBoardParaSlotIndex OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION " This node is not supported. " ::= { hwXPONBoardParaEntry 2 } hwXPONBoardSN OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..96)) MAX-ACCESS read-only STATUS current DESCRIPTION " This node is not supported. " ::= { hwXPONBoardParaEntry 3 } hwXPONBoardPassWord OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..96)) MAX-ACCESS read-write STATUS current DESCRIPTION " This node is not supported. " ::= { hwXPONBoardParaEntry 4 } hwXPONBoardMacAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE(17..17)) MAX-ACCESS read-only STATUS current DESCRIPTION " This node is not supported. " ::= { hwXPONBoardParaEntry 5 } hwBroadBandFrameOperTable OBJECT-TYPE SYNTAX SEQUENCE OF HwBroadBandFrameOperEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The indexes of this table are hwFrameIndex and hwSlotIndex. This table is not supported. " ::= { hwIasDev 2 } hwBroadBandFrameOperEntry OBJECT-TYPE SYNTAX HwBroadBandFrameOperEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The indexes of this entry are hwFrameIndex and hwSlotIndex. This table is not supported. " INDEX { hwFrameIfIndex } ::= { hwBroadBandFrameOperTable 1 } HwBroadBandFrameOperEntry ::= SEQUENCE { hwFrameIfIndex Integer32, hwBroadBandFrameType HWFrameType, hwMainBoardSlots Integer32, hwMainBoardType HWPCBType, hwBroadBandFrameID Integer32, hwBroadBandFrameRowStatus RowStatus } hwFrameIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION " This node is not supported. " ::= { hwBroadBandFrameOperEntry 1 } hwBroadBandFrameType OBJECT-TYPE SYNTAX HWFrameType MAX-ACCESS not-accessible STATUS current DESCRIPTION " This node is not supported. " ::= { hwBroadBandFrameOperEntry 2 } hwMainBoardSlots OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This node is not supported. " ::= { hwBroadBandFrameOperEntry 3 } hwMainBoardType OBJECT-TYPE SYNTAX HWPCBType MAX-ACCESS read-write STATUS current DESCRIPTION " This node is not supported. " ::= { hwBroadBandFrameOperEntry 4 } hwBroadBandFrameID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " This node is not supported. " ::= { hwBroadBandFrameOperEntry 5 } hwBroadBandFrameRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION " This node is not supported. " ::= { hwBroadBandFrameOperEntry 6 } hwIasConfigChange OBJECT IDENTIFIER ::= { ias 5 } hwIasConfigChangeTable OBJECT-TYPE SYNTAX SEQUENCE OF HwIasConfigChangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Configuration change type trap table. The index of this table is hwIasConfigChangeTrapID. It is the trap ID. " ::= { hwIasConfigChange 1 } hwIasConfigChangeEntry OBJECT-TYPE SYNTAX HwIasConfigChangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Configuration change type trap table. The index of this entry is hwIasConfigChangeTrapID. It is the trap ID. " INDEX { hwIasConfigChangeTrapID } ::= { hwIasConfigChangeTable 1 } HwIasConfigChangeEntry ::= SEQUENCE { hwIasConfigChangeTrapID Integer32, hwIasConfigChangeSerialSN Integer32 } hwIasConfigChangeTrapID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION " Configuration change type trap ID. " ::= { hwIasConfigChangeEntry 1 } hwIasConfigChangeSerialSN OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Configuration change type trap serial number. " ::= { hwIasConfigChangeEntry 2 } hwMusaFramePowerSupplyTable OBJECT-TYPE SYNTAX SEQUENCE OF HwMusaFramePowerSupplyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The power supply query table. The table is used to get supply state of all the power supply input. The index of this table is hwFrameIndex,hwMusaPowerSupplyInputMode and hwMusaPowerSupplyID. " ::= { hwMusaSlotConf 5 } hwMusaFramePowerSupplyEntry OBJECT-TYPE SYNTAX HwMusaFramePowerSupplyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The power supply query table. The table is used to get supply state of all the power supply input. The index of this entry is hwFrameIndex,hwMusaPowerSupplyInputMode and hwMusaPowerSupplyID. " INDEX { hwFrameIndex, hwMusaPowerSupplyInputMode, hwMusaPowerSupplyID } ::= { hwMusaFramePowerSupplyTable 1 } HwMusaFramePowerSupplyEntry ::= SEQUENCE { hwMusaPowerSupplyInputMode INTEGER, hwMusaPowerSupplyID Integer32, hwMusaPowerSupplyState INTEGER } hwMusaPowerSupplyInputMode OBJECT-TYPE SYNTAX INTEGER { localac(1), localdc(2), remoteac(3), remotedc(4), pd(5) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Power supply input mode. Options: 1. localac(1) -local 220V AC power supply 2. localdc(2) -local DC power supply 3. remoteac(3) -remote 60V AC power supply 4. remotedc(4) -remote line +/-190V high voltage power supply of DC 5. pd(5) -powered device supply " ::= { hwMusaFramePowerSupplyEntry 1 } hwMusaPowerSupplyID OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The input index of power supply." ::= { hwMusaFramePowerSupplyEntry 2 } hwMusaPowerSupplyState OBJECT-TYPE SYNTAX INTEGER { valid(1), invalid(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of power supply. Options: 1. valid(1) -this power input is working 2. invalid(2) -this power input is not working " ::= { hwMusaFramePowerSupplyEntry 3 } END