-- ******************************************************************************** -- File : mmblade.mib -- Description : Management Module MIB for SNMP -- Version : 6.3 -- Date : July 2013 -- Copyright (c) 2002-2013 IBM All Rights Reserved. -- ******************************************************************************** -- -- Contains MIB description for: -- This MIB is to be used to provide configuration support and monitoring for the -- BladeCenter, BladeCenter T, BladeCenter H, and BladeCenter HT. -- ******************************************************************************** BLADE-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 enterprises FROM RFC1155-SMI -- DisplayString FROM RFC1213-MIB IpAddress FROM RFC1155-SMI TRAP-TYPE FROM RFC-1215; -- textual conventions InetAddressIPv6 ::= TEXTUAL-CONVENTION DISPLAY-HINT "2x:2x:2x:2x:2x:2x:2x:2x" STATUS current DESCRIPTION "Represents an IPv6 network address. Since MIB browsers may require different formats, the address is expected to be the 16 byte address in network-byte order, and shortened formats such as 0::0 are not accepted in SET operations. Two common examples are: The NetSNMP command line will accept SET requests like: snmpset -v1 -cprivate s 2001:00:00:00:FFFF:CCC4:BBB2:AAA6 Other MIB browsers may require the SET request value to be formatted as: # 0x20 0x01 0x00 0x00 0x00 0x00 0x00 0x00 0xFF 0xFF 0xCC 0xC4 0xBB 0xB2 0xAA 0xA6" SYNTAX OCTET STRING (SIZE (16)) EntryStatus ::= INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } -- The status of a table entry. -- -- Setting this object to the value invalid(4) has the -- effect of invalidating the corresponding entry. -- That is, it effectively disassociates the mapping -- identified with said entry. -- It is an implementation-specific matter as to whether -- the agent removes an invalidated entry from the table. -- Accordingly, management stations must be prepared to -- receive tabular information from agents that corresponds -- to entries currently not in use. Proper -- interpretation of such entries requires examination -- of the relevant EntryStatus object. -- -- An existing instance of this object cannot be set to -- createRequest(2). This object may only be set to -- createRequest(2) when this instance is created. When -- this object is created, the agent may wish to create -- supplemental object instances to complete a conceptual -- row in this table. Immediately after completing the -- create operation, the agent must set this object to -- underCreation(3). -- -- Entries shall exist in the underCreation(3) state until -- the management station is finished configuring the -- entry and sets this object to valid(1) or aborts, -- setting this object to invalid(4). If the agent -- determines that an entry has been in the -- underCreation(3) state for an abnormally long time, -- it may decide that the management station has -- crashed. If the agent makes this decision, -- it may set this object to invalid(4) to reclaim the -- entry. A prudent agent will understand that the -- management station may need to wait for human input -- and will allow for that possibility in its -- determination of this abnormally long period. -- IBM enterprise group ibm OBJECT IDENTIFIER ::= { enterprises 2 } -- IBM products group ibmAgents OBJECT IDENTIFIER ::= { ibm 3 } -- IBM Advanced System Management Support Processor (SP) agent group netfinitySupportProcessorAgent OBJECT IDENTIFIER ::= { ibmAgents 51 } -- IBM BladeCenter Management Module (MM) -- Also known as Advanced System Mangement (ASM) or Support Processor (SP) bladeCenterSnmpMIB OBJECT IDENTIFIER ::= { netfinitySupportProcessorAgent 2 } -- ******************************************************************************** -- Start: Define groups of objects within the bladeCenterSnmpMIB -- ******************************************************************************** -- This group of objects provides the various environmental monitors for the -- local system and the MM monitors OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 2 } -- This group of objects provides the error log objects for the MM errorLogs OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 3 } -- This group of objects provides configuration functions for the MM configureSP OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 4 } -- This group of objects provides system management functions for BladeCenter T telcoManagement OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 5 } -- This group of objects provides configuration functions for system power -- systemPower OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 6 } -- This group of objects provides functions to boot the MM and system restartReset OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 7 } -- This group of objects provides information specific to blades blades OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 22 } -- This group of objects provides information on the PCI-X expansion enclosure -- pcixExpansionBox OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 21 } -- This group of objects provides information specific to service service OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 23 } -- This group of objects provides information specific to scaling blades scaling OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 24 } -- ******************************************************************************** -- Temperature -- ******************************************************************************** temperature OBJECT IDENTIFIER ::= { monitors 1 } -- Planar Temperature planarTemp OBJECT IDENTIFIER ::= { temperature 1 } mmTemp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system." ::= { planarTemp 2 } -- CPUx Temperature -- cpuXTemp OBJECT IDENTIFIER ::= { temperature 2 } -- System Ambient Temperature ambientTemp OBJECT IDENTIFIER ::= { temperature 5 } frontPanelTemp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The front panel temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system." ::= { ambientTemp 1 } frontPanel2Temp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The front panel 2 temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for BladeCenter HT only" ::= { ambientTemp 2 } -- ******************************************************************************** -- Voltages -- ******************************************************************************** voltage OBJECT IDENTIFIER ::= { monitors 2 } -- Planar Voltages planarVolt OBJECT IDENTIFIER ::= { voltage 1 } plus5Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "+5 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system." ::= { planarVolt 1 } plus3Pt3Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "+3.3 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system." ::= { planarVolt 2 } plus12Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "+12 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system." ::= { planarVolt 3 } minus5Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "-5 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system." ::= { planarVolt 5 } plus2Pt5Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "+2.5 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system." ::= { planarVolt 6 } plus1Pt8Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "+1.8 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system." ::= { planarVolt 8 } -- ******************************************************************************** -- Blowers -- ******************************************************************************** blowers OBJECT IDENTIFIER ::= { monitors 3 } blower1speed OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower 1 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 1 } blower2speed OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower 2 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 2 } blower3speed OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower 3 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for BladeCenter T, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 3 } blower4speed OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower 4 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for BladeCenter T, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 4 } blower1State OBJECT-TYPE SYNTAX INTEGER { unknown(0), good(1), warning(2), bad(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The health state for blower 1. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 10} blower2State OBJECT-TYPE SYNTAX INTEGER { unknown(0), good(1), warning(2), bad(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The health state for blower 2. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 11} blower3State OBJECT-TYPE SYNTAX INTEGER { unknown(0), good(1), warning(2), bad(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The health state for blower 3. NOTE: This MIB object is for BladeCenter T and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 12} blower4State OBJECT-TYPE SYNTAX INTEGER { unknown(0), good(1), warning(2), bad(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The health state for blower 4. NOTE: This MIB object is for BladeCenter T and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 13} blower1speedRPM OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower 1 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 20 } blower2speedRPM OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower 2 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 21 } blower3speedRPM OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower 3 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 22 } blower4speedRPM OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower 4 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system. NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 23 } blower1ControllerState OBJECT-TYPE SYNTAX INTEGER { operational(0), flashing(1), notPresent(2), communicationError(3), unknown(255) } ACCESS read-only STATUS mandatory DESCRIPTION "The health state for the controller for blower 1. NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 30} blower2ControllerState OBJECT-TYPE SYNTAX INTEGER { operational(0), flashing(1), notPresent(2), communicationError(3), unknown(255) } ACCESS read-only STATUS mandatory DESCRIPTION "The health state for the controller for blower 2. NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 31} blower3ControllerState OBJECT-TYPE SYNTAX INTEGER { operational(0), flashing(1), notPresent(2), communicationError(3), unknown(255) } ACCESS read-only STATUS mandatory DESCRIPTION "The health state for the controller for blower 3. NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 32} blower4ControllerState OBJECT-TYPE SYNTAX INTEGER { operational(0), flashing(1), notPresent(2), communicationError(3), unknown(255) } ACCESS read-only STATUS mandatory DESCRIPTION "The health state for the controller for blower 4. NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 33} blower1ExhaustTemp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The exhaust temperature in degrees Celsius for blower 1. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 40} blower2ExhaustTemp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The exhaust temperature in degrees Celsius for blower 2. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 41} blower3ExhaustTemp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The exhaust temperature in degrees Celsius for blower 3. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 42} blower4ExhaustTemp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The exhaust temperature in degrees Celsius for blower 4. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowers 43} -- ******************************************************************************** -- Power Module Health State -- ******************************************************************************** powerModuleHealth OBJECT IDENTIFIER ::= { monitors 4 } powerModuleHealthTable OBJECT-TYPE SYNTAX SEQUENCE OF PowerModuleHealthEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of power module health information. Contains the power health information for each power module." ::= { powerModuleHealth 1 } powerModuleHealthEntry OBJECT-TYPE SYNTAX PowerModuleHealthEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Power Module health entry" INDEX { powerModuleIndex } ::= { powerModuleHealthTable 1 } PowerModuleHealthEntry ::= SEQUENCE { powerModuleIndex INTEGER, powerModuleExists INTEGER, powerModuleState INTEGER, powerModuleDetails OCTET STRING } powerModuleIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Power module sequence index." ::= { powerModuleHealthEntry 1 } powerModuleExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the power module specified exists or not." ::= { powerModuleHealthEntry 2 } powerModuleState OBJECT-TYPE SYNTAX INTEGER { unknown(0), good(1), warning(2), notAvailable(3), critical(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The health state for the power module." ::= { powerModuleHealthEntry 3} powerModuleDetails OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The details for this power module." ::= { powerModuleHealthEntry 4 } -- ******************************************************************************** -- MM Status -- ******************************************************************************** spStatus OBJECT IDENTIFIER ::= { monitors 5 } mmBistAndChassisStatus OBJECT IDENTIFIER ::= { spStatus 2 } bistSdram OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS deprecated DESCRIPTION "MM BIST DRAM test result. NOTE: This Mib object is deprecated and no longer supported." ::= { mmBistAndChassisStatus 1 } bistRs485Port1 OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST RS 485 legacy test result." ::= { mmBistAndChassisStatus 2 } bistRs485Port2 OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST RS 485 local bus test result." ::= { mmBistAndChassisStatus 3 } bistNvram OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS deprecated DESCRIPTION "MM BIST NVRAM test result. NOTE: This Mib object is deprecated and no longer supported." ::= { mmBistAndChassisStatus 4 } bistRtc OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST Real Time Clock test result." ::= { mmBistAndChassisStatus 5 } bistLocalI2CBus OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST Local I2C bus test result." ::= { mmBistAndChassisStatus 7 } bistPrimaryMainAppFlashImage OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST Primary Main Application Firmware test result." ::= { mmBistAndChassisStatus 8 } bistSecondaryMainAppFlashImage OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST Secondary Main Application test result." ::= { mmBistAndChassisStatus 9 } bistBootRomFlashImage OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST Boot Firmware test result." ::= { mmBistAndChassisStatus 10 } bistEthernetPort1 OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST external ethernet port test result." ::= { mmBistAndChassisStatus 11 } bistEthernetPort2 OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS deprecated DESCRIPTION "MM BIST internal ethernet port test result. NOTE: This Mib object is deprecated and no longer supported." ::= { mmBistAndChassisStatus 12 } bistInternalPCIBus OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS deprecated DESCRIPTION "MM BIST PCI bus test result. NOTE: This Mib object is deprecated and no longer supported." ::= { mmBistAndChassisStatus 13 } bistExternalI2CDevices OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST external I2C devices test result." ::= { mmBistAndChassisStatus 14 } bistUSBController OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS deprecated DESCRIPTION "MM BIST USB controller test result. NOTE: This Mib object is deprecated and no longer supported." ::= { mmBistAndChassisStatus 15 } bistVideoCompressorBoard OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS deprecated DESCRIPTION "MM BIST Video Compressor Board test result. NOTE: This Mib object is deprecated and no longer supported." ::= { mmBistAndChassisStatus 16 } bistRemoteVideo OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS deprecated DESCRIPTION "MM BIST Remote Video test result. NOTE: This Mib object is deprecated and no longer supported." ::= { mmBistAndChassisStatus 17 } bistPrimaryBus OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST primary mid-plane bus test result." ::= { mmBistAndChassisStatus 18 } bistInternalEthernetSwitch OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST internal external switch test result." ::= { mmBistAndChassisStatus 19 } bistVideoCapture OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST video capture test result." ::= { mmBistAndChassisStatus 20 } bistUSBKeyboardMouseEmulation OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST USB keyboard and mouse test result." ::= { mmBistAndChassisStatus 21 } bistUSBMassStorageEmulation OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST mass storage emulation test result." ::= { mmBistAndChassisStatus 22 } bistUSBKeyboardMouseFirmware OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST USB keyboard and mouse firmware test result." ::= { mmBistAndChassisStatus 23 } bistUSBMassStorageFirmware OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST USB keyboard mouse firmware test result." ::= { mmBistAndChassisStatus 24 } bistPrimaryCore OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST primary core test result." ::= { mmBistAndChassisStatus 25 } bistSecondaryCore OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST secondary core test result." ::= { mmBistAndChassisStatus 26 } bistInternalIOExpander OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST internal IO expander test result." ::= { mmBistAndChassisStatus 27 } bistRemoteControlFirmware OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST Remote Control firmware test result." ::= { mmBistAndChassisStatus 28 } bistPhysicalNetworkLink OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST Physical Network Link test result." ::= { mmBistAndChassisStatus 29 } bistLogicalNetworkLink OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "MM BIST Logical Network Link test result." ::= { mmBistAndChassisStatus 30 } bistBladesInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blades that are installed on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are installed in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'." ::= { mmBistAndChassisStatus 33 } bistBladesCommunicating OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blades that are communicating on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade installed in a bay is communicating, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are communicating in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'." ::= { mmBistAndChassisStatus 49 } bistBlowersInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blowers that are installed on the chassis. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { mmBistAndChassisStatus 65 } bistBlowersFunctional OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blowers installed on the chassis that are functional. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed and functional in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed and functional only in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { mmBistAndChassisStatus 73 } bistMediaTrayInstalled OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether a media tray is installed on the chassis." ::= { mmBistAndChassisStatus 74 } bistMediaTrayCommunicating OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether a media tray is communicating." ::= { mmBistAndChassisStatus 75 } bistOtherMMInstalled OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether a redundant MM is installed." ::= { mmBistAndChassisStatus 76 } bistOtherMMCommunicating OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether a redundant MM is communicating." ::= { mmBistAndChassisStatus 77 } bistPowerModulesInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The power modules that are installed on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'." ::= { mmBistAndChassisStatus 81 } bistPowerModulesFunctional OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The power modules that are functional on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed and functioning in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'." ::= { mmBistAndChassisStatus 89 } bistSwitchModulesInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The switch modules that are installed on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed in bays 1 and 3, and 4 switch modules are supported, the string would look like '1011' for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT." ::= { mmBistAndChassisStatus 97 } bistSwitchModulesCommunicating OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The switch modules that are communicating on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed and functioning in bays 1 and 3, and 4 switch modules are supported, the string would look like for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT." ::= { mmBistAndChassisStatus 113 } bistLastUpdate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "It is the time when the primary MM updated the last BIST results." ::= { mmBistAndChassisStatus 200 } rmmBistAndChassisStatus OBJECT IDENTIFIER ::= { spStatus 3 } rbistRs485Port1 OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST RS 485 legacy test result. The time of the last update can be obtained by querying rbistUpdateTime object." ::= { rmmBistAndChassisStatus 2 } rbistRs485Port2 OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST RS 485 local bus test result. The time of the last update can be obtained by querying rbistUpdateTime object." ::= { rmmBistAndChassisStatus 3 } rbistRtc OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST Real Time Clock test result. The time of the last update can be obtained by querying rbistUpdateTime object." ::= { rmmBistAndChassisStatus 5 } rbistLocalI2CBus OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST Local I2C bus test result. The time of the last update can be obtained by querying rbistUpdateTime object." ::= { rmmBistAndChassisStatus 7 } rbistPrimaryMainAppFlashImage OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST Primary Main Application Firmware test result. The time of the last update can be obtained by querying rbistUpdateTime object." ::= { rmmBistAndChassisStatus 8 } rbistSecondaryMainAppFlashImage OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST Secondary Main Application test result. The time of the last update can be obtained by querying rbistUpdateTime object." ::= { rmmBistAndChassisStatus 9 } rbistBootRomFlashImage OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST Boot Firmware test result. The time of the last update can be obtained by querying rbistUpdateTime object." ::= { rmmBistAndChassisStatus 10 } rbistEthernetPort1 OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST external ethernet port test result. The time of the last update can be obtained by querying rbistUpdateTime object." ::= { rmmBistAndChassisStatus 11 } rbistExternalI2CDevices OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST external I2C devices test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object." ::= { rmmBistAndChassisStatus 14 } rbistInternalEthernetSwitch OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST internal external switch test result. The time of the last update can be obtained by querying rbistUpdateTime object." ::= { rmmBistAndChassisStatus 19 } rbistVideoCapture OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST video capture test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object." ::= { rmmBistAndChassisStatus 20 } rbistUSBKeyboardMouseEmulation OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST USB keyboard and mouse test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object." ::= { rmmBistAndChassisStatus 21 } rbistUSBMassStorageEmulation OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST mass storage emulation test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object." ::= { rmmBistAndChassisStatus 22 } rbistUSBKeyboardMouseFirmware OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST USB keyboard and mouse firmware test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object." ::= { rmmBistAndChassisStatus 23 } rbistUSBMassStorageFirmware OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST USB keyboard mouse firmware test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object." ::= { rmmBistAndChassisStatus 24 } rbistPrimaryCore OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST primary core test result. The time of the last update can be obtained by querying rbistUpdateTime object." ::= { rmmBistAndChassisStatus 25 } rbistSecondaryCore OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST secondary core test result. The time of the last update can be obtained by querying rbistUpdateTime object." ::= { rmmBistAndChassisStatus 26 } rbistInternalIOExpander OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST internal IO expander test result. The time of the last update can be obtained by querying rbistUpdateTime object." ::= { rmmBistAndChassisStatus 27 } rbistRemoteControlFirmware OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST Remote Control firmware test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object." ::= { rmmBistAndChassisStatus 28 } rbistPhysicalNetworkLink OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST Physical Network Link test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object." ::= { rmmBistAndChassisStatus 29 } rbistLogicalNetworkLink OBJECT-TYPE SYNTAX INTEGER { testSucceeded(0), testFailed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Standby MM BIST Logical Network Link test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object." ::= { rmmBistAndChassisStatus 30 } rbistBladesInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blades that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are installed in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'. " ::= { rmmBistAndChassisStatus 33 } rbistBladesCommunicating OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blades that were communicating on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade installed in a bay is communicating, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are communicating in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'." ::= { rmmBistAndChassisStatus 49 } rbistBlowersInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blowers that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { rmmBistAndChassisStatus 65 } rbistBlowersFunctional OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blowers installed on the chassis that were functional when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed and functional in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed and functional only in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { rmmBistAndChassisStatus 73 } rbistMediaTrayInstalled OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether a media tray was installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object." ::= { rmmBistAndChassisStatus 74 } rbistMediaTrayCommunicating OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether a media tray was communicating when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object." ::= { rmmBistAndChassisStatus 75 } rbistOtherMMInstalled OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether a standby MM was installed when the standby MM was once primary.The time of the last update can be obtained by querying rbistUpdateTimePrimary object." ::= { rmmBistAndChassisStatus 76 } rbistOtherMMCommunicating OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether a standby MM was communicating when the standby MM was once primary. The time of the last update can be gotten from the object 'rbistUpdateTimePrimary'." ::= { rmmBistAndChassisStatus 77 } rbistPowerModulesInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The power modules that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module was installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules were installed in bays 1 and 3, and 4 power modules were supported, the string would look like '1010'." ::= { rmmBistAndChassisStatus 81 } rbistPowerModulesFunctional OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The power modules that were functional on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module was installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules were installed and functioning in bays 1 and 3, and 4 power modules were supported, the string would look like '1010'." ::= { rmmBistAndChassisStatus 89 } rbistSwitchModulesInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The switch modules that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module was installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules were installed in bays 1 and 3, and 4 switch modules were supported, the string would look like '1011' for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT." ::= { rmmBistAndChassisStatus 97 } rbistSwitchModulesCommunicating OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The switch modules that are communicating on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrimary object. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module was installed and functioning in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules were installed and functioning in bays 1 and 3, and 4 switch modules were supported, the string would look like for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT." ::= { rmmBistAndChassisStatus 113 } rbistUpdateTime OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "It is the time when the standby MM updated the last BIST results." ::= { rmmBistAndChassisStatus 200 } rbistLastUpdatePrimary OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "It is the time when the standby MM updated the last BIST results when it was still primary." ::= { rmmBistAndChassisStatus 201 } -- ******************************************************************************** -- Fan Pack Health State -- ******************************************************************************** fanPack OBJECT IDENTIFIER ::= { monitors 6 } fanPackTable OBJECT-TYPE SYNTAX SEQUENCE OF FanPackEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of fan pack information. Contains the information for each fan pack. NOTE: Fan packs are also referred to as Power Module Cooling Devices." ::= { fanPack 1 } fanPackEntry OBJECT-TYPE SYNTAX FanPackEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Fan Pack entry" INDEX { fanPackIndex } ::= { fanPackTable 1 } FanPackEntry ::= SEQUENCE { fanPackIndex INTEGER, fanPackExists INTEGER, fanPackState INTEGER, fanPackFanCount INTEGER, fanPackAverageSpeed OCTET STRING, fanPackAverageSpeedRPM OCTET STRING, fanPackControllerState INTEGER } fanPackIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Fan Pack sequence index." ::= { fanPackEntry 1 } fanPackExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the fan pack specified exists or not." ::= { fanPackEntry 2 } fanPackState OBJECT-TYPE SYNTAX INTEGER { unknown(0), good(1), warning(2), bad(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The health state for the fan pack. 0 = unknown, 1 = good, 2 = warning, 3 = bad." ::= { fanPackEntry 3} fanPackFanCount OBJECT-TYPE SYNTAX INTEGER { unknown(255) } ACCESS read-only STATUS mandatory DESCRIPTION "The number of fans in the fan pack." ::= { fanPackEntry 4 } fanPackAverageSpeed OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The average speed of all fans in the fan pack expressed in percent(%) of maximum RPM. If the fan pack is determined not to be running or the fan pack speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system." ::= { fanPackEntry 5 } fanPackAverageSpeedRPM OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The average speed of all fans in the fan pack expressed in RPM. If the fan pack is determined not to be running or the fan pack speed cannot be determined, the string will indicate 'Offline'. The string 'Not Readable!' indicates that the given monitor is not supported on this system." ::= { fanPackEntry 6 } fanPackControllerState OBJECT-TYPE SYNTAX INTEGER { operational(0), flashing(1), notPresent(2), communicationError(3), unknown(255) } ACCESS read-only STATUS mandatory DESCRIPTION "The health state for the controller for the fan pack. 0 = operational, 1 = flashing in progress, 2 = not present, 3 = communication error, 255 = unknown" ::= { fanPackEntry 7} -- ******************************************************************************** -- System Health -- ******************************************************************************** systemHealth OBJECT IDENTIFIER ::= { monitors 7 } -- ******************************************************************************** -- System Health Status -- ******************************************************************************** systemHealthStat OBJECT-TYPE SYNTAX INTEGER { critical(0), nonCritical(2), systemLevel(4), normal(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates status of system health for the system in which the MM resides. Value of 'critical' indicates a severe error has occurred and the system may not be functioning. A value of 'nonCritical' indicates that a error has occurred but the system is currently functioning properly. A value of 'systemLevel' indicates that a condition has occurred that may change the state of the system in the future but currently the system is working properly. A value of 'normal' indicates that the system is operating normally." ::= { systemHealth 1 } -- ******************************************************************************** -- System Health Summary -- ******************************************************************************** systemHealthSummaryTable OBJECT-TYPE SYNTAX SEQUENCE OF SystemHealthSummaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of System Health summary. Contains more detailed information about the reasons for the overall system health status. NOTE: This MIB object is for BladeCenter only." ::= { systemHealth 2 } systemHealthSummaryEntry OBJECT-TYPE SYNTAX SystemHealthSummaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "System Health Summary entry NOTE: This MIB object is for BladeCenter only." INDEX { systemHealthSummaryIndex } ::= { systemHealthSummaryTable 1 } SystemHealthSummaryEntry ::= SEQUENCE { systemHealthSummaryIndex INTEGER, systemHealthSummarySeverity OCTET STRING, systemHealthSummaryDescription OCTET STRING, systemHealthSummaryDateTime OCTET STRING } systemHealthSummaryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "System health summary index. NOTE: This MIB object is for BladeCenter only." ::= { systemHealthSummaryEntry 1 } systemHealthSummarySeverity OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "System health summary severity. NOTE: This MIB object is for BladeCenter only." ::= { systemHealthSummaryEntry 2 } systemHealthSummaryDescription OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "System health summary description. NOTE: This MIB object is for BladeCenter only." ::= { systemHealthSummaryEntry 3 } systemHealthSummaryDateTime OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "System health summary date time. NOTE: This MIB object is for BladeCenter only." ::= { systemHealthSummaryEntry 4 } -- ******************************************************************************** -- LEDs -- ******************************************************************************** leds OBJECT IDENTIFIER ::= { monitors 8 } -- ******************************************************************************** -- Front Panel LEDs -- ******************************************************************************** frontPanelLEDs OBJECT IDENTIFIER ::= { leds 1 } systemErrorLED OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the front panel system error LED is on or off. NOTE: This MIB object is for BladeCenter only." ::= { frontPanelLEDs 1 } informationLED OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the front panel system information LED is on or off. For Write access, the LED can be turned off only. NOTE: This MIB object is for BladeCenter only." ::= { frontPanelLEDs 2 } temperatureLED OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the front panel temperature LED is on or off. NOTE: This MIB object is for BladeCenter only." ::= { frontPanelLEDs 3 } identityLED OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), blinking(2), notAvailable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the front panel identity LED is on or off. NOTE: This MIB object is for BladeCenter only." ::= { frontPanelLEDs 4 } -- ******************************************************************************** -- Blade LEDs -- ******************************************************************************** bladeLEDs OBJECT IDENTIFIER ::= { leds 2 } bladeLEDsTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeLEDsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade status information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout be set to a large value. On a fully populated chassis, the timeout should be set to 120 seconds or more." ::= { bladeLEDs 1 } bladeLEDsEntry OBJECT-TYPE SYNTAX BladeLEDsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade system status entry" INDEX { bladeStatusIndex } ::= { bladeLEDsTable 1 } BladeLEDsEntry ::= SEQUENCE { ledBladeIndex INTEGER, ledBladeId INTEGER, ledBladeExists INTEGER, ledBladePowerState INTEGER, ledBladeHealthState INTEGER, ledBladeName OCTET STRING, ledBladeSystemError INTEGER, ledBladeInformation INTEGER, ledBladeKVM INTEGER, ledBladeMediaTray INTEGER, ledBladeIdentity INTEGER } ledBladeIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade LED table index." ::= { bladeLEDsEntry 1 } ledBladeId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { bladeLEDsEntry 2 } ledBladeExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the server blade specified exists or not." ::= { bladeLEDsEntry 3 } ledBladePowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), standby(3), hibernate(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the power state of the blade specified." ::= { bladeLEDsEntry 4 } ledBladeHealthState OBJECT-TYPE SYNTAX INTEGER { unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11) } ACCESS read-only STATUS mandatory DESCRIPTION "The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade." ::= { bladeLEDsEntry 5 } ledBladeName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the blade as a null terminated string." ::= { bladeLEDsEntry 6 } ledBladeSystemError OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the blade system error LED is on or off." ::= { bladeLEDsEntry 7 } ledBladeInformation OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the blade information LED is on or off. For Write access, the LED can be turned off only." ::= { bladeLEDsEntry 8 } ledBladeKVM OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), blinking(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the blade KVM LED is on, off, or blinking." ::= { bladeLEDsEntry 9 } ledBladeMediaTray OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), blinking(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the blade media tray LED is on, off, or blinking." ::= { bladeLEDsEntry 10 } ledBladeIdentity OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), blinking(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the blade identify LED is on, off, or blinking." ::= { bladeLEDsEntry 11 } bladeLEDsDetailsTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeLEDsDetailsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade LEDs detailed information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout be set to a large value. On a fully populated chassis, the timeout should be set to 120 seconds or more." ::= { bladeLEDs 2 } bladeLEDsDetailsEntry OBJECT-TYPE SYNTAX BladeLEDsDetailsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade LEDs Details entry" INDEX { ledIndex } ::= { bladeLEDsDetailsTable 1 } BladeLEDsDetailsEntry ::= SEQUENCE { ledIndex INTEGER, ledBladeBayNumber OCTET STRING, ledBladeComponentType OCTET STRING, ledBladeLabel OCTET STRING, ledBladeState INTEGER, ledBladeLocation OCTET STRING } ledIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The LED index number. For consistent results, view as a table and not as individual entries." ::= { bladeLEDsDetailsEntry 1 } ledBladeBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The bay number of the main server blade that the LED is grouped into. For consistent results, view as a table and not as individual entries." ::= { bladeLEDsDetailsEntry 2 } ledBladeComponentType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Type of the component/subcomponent grouping for this LED. For consistent results, view as a table and not as individual entries." ::= { bladeLEDsDetailsEntry 3 } ledBladeLabel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Text label for a LED. For consistent results, view as a table and not as individual entries." ::= { bladeLEDsDetailsEntry 4 } ledBladeState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), blinking(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Text description which denotes color or on/off/blink state for a LED. For consistent results, view as a table and not as individual entries." ::= { bladeLEDsDetailsEntry 5 } ledBladeLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Location of this LED. For consistent results, view as a table and not as individual entries." ::= { bladeLEDsDetailsEntry 6 } -- *********************************************************************** -- BladeCenter T Panel LEDs -- *********************************************************************** telcoPanelLEDs OBJECT IDENTIFIER ::= { leds 3 } criticalLED OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the BladeCenter T Panel CRT (Critical) LED is on or off. NOTE: This MIB object is for BladeCenter T only." ::= { telcoPanelLEDs 1 } majorLED OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the BladeCenter T Panel MJR (Major) LED is on or off. NOTE: This MIB object is for BladeCenter T only." ::= { telcoPanelLEDs 2 } minorLED OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the BladeCenter T Panel MNR (Minor) LED is on or off. NOTE: This MIB object is for BladeCenter T only." ::= { telcoPanelLEDs 3 } telcoIdentityLED OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), blinking(2), notAvailable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the BladeCenter T Panel identity LED is on or off. NOTE: This MIB object is for BladeCenter T only." ::= { telcoPanelLEDs 4 } telcoColorSel OBJECT-TYPE SYNTAX INTEGER { amber(0), red(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the BladeCenter T Critical and Major LEDs are displayed in amber or red color. NOTE: This MIB object is for BladeCenter T only." ::= { telcoPanelLEDs 5 } criticalityAssertionMode OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the BladeCenter T Criticality Assertion Mode is enabled or disabled. NOTE: This MIB object is for BladeCenter T only." ::= { telcoPanelLEDs 6 } -- ******************************************************************************** -- Switch Module LEDs -- ******************************************************************************** smLEDs OBJECT IDENTIFIER ::= { leds 4 } smLEDsTable OBJECT-TYPE SYNTAX SEQUENCE OF SMLEDsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of switch module LEDs information." ::= { smLEDs 1 } smLEDsEntry OBJECT-TYPE SYNTAX SMLEDsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module LEDs information entry" INDEX { ledSMIndex } ::= { smLEDsTable 1 } SMLEDsEntry ::= SEQUENCE { ledSMIndex INTEGER, ledSMLEDs OCTET STRING } ledSMIndex OBJECT-TYPE SYNTAX INTEGER (0..128) ACCESS read-only STATUS mandatory DESCRIPTION "Switch module LEDs table index. " ::= { smLEDsEntry 1 } ledSMLEDs OBJECT-TYPE SYNTAX OCTET STRING (SIZE(256)) ACCESS read-only STATUS mandatory DESCRIPTION "A bitmap of LEDs information on the selected switch module. The bitmap is a string containing a list of 1's and 0's. Every 4 bytes are used to represent a led state. The first 64 bytes represent the status of the external LEDs while the last 64 bytes represent the status of the internal port connections from the switch module to blades. Each nibble of data is presented in the bitmap format (0000) and is encoded as followed - 0000: LED is not present - 0001: LED is off - 0010: LED is on NOTE: The data is read from left to right, starting out with blade server 1 and so on." ::= { smLEDsEntry 2 } -- ******************************************************************************** -- Blower LEDs -- ******************************************************************************** blowerLEDs OBJECT IDENTIFIER ::= { leds 5 } blowerLEDsTable OBJECT-TYPE SYNTAX SEQUENCE OF BlowerLEDsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blower LEDs information. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowerLEDs 1 } blowerLEDsEntry OBJECT-TYPE SYNTAX BlowerLEDsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blower LEDs information entry" INDEX { ledBlowerIndex } ::= { blowerLEDsTable 1 } BlowerLEDsEntry ::= SEQUENCE { ledBlowerIndex INTEGER, ledBlowerId INTEGER, ledBlowerExists INTEGER, ledBlowerError INTEGER } ledBlowerIndex OBJECT-TYPE SYNTAX INTEGER (0..128) ACCESS read-only STATUS mandatory DESCRIPTION "Blower LEDs table index. " ::= { blowerLEDsEntry 1 } ledBlowerId OBJECT-TYPE SYNTAX INTEGER { blower1(1), blower2(2), blower3(3), blower4(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { blowerLEDsEntry 2 } ledBlowerExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the blower specified exists or not." ::= { blowerLEDsEntry 3 } ledBlowerError OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), notAvailable(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the blower error LED is on, off, or not available." ::= { blowerLEDsEntry 4 } -- ******************************************************************************** -- Fan Pack LEDs -- ******************************************************************************** fanPackLEDs OBJECT IDENTIFIER ::= { leds 6 } fanPackLEDsTable OBJECT-TYPE SYNTAX SEQUENCE OF FanPackLEDsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of fan pack LEDs information. NOTE: Fan packs are also referred to as Power Module Cooling Devices." ::= { fanPackLEDs 1 } fanPackLEDsEntry OBJECT-TYPE SYNTAX FanPackLEDsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Fan Pack LEDs information entry" INDEX { ledFanPackIndex } ::= { fanPackLEDsTable 1 } FanPackLEDsEntry ::= SEQUENCE { ledFanPackIndex INTEGER, ledFanPackId INTEGER, ledFanPackExists INTEGER, ledFanPackError INTEGER } ledFanPackIndex OBJECT-TYPE SYNTAX INTEGER (0..128) ACCESS read-only STATUS mandatory DESCRIPTION "Fan Pack LEDs table index. " ::= { fanPackLEDsEntry 1 } ledFanPackId OBJECT-TYPE SYNTAX INTEGER { fanPack1(1), fanPack2(2), fanPack3(3), fanPack4(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric fan pack ID." ::= { fanPackLEDsEntry 2 } ledFanPackExists OBJECT-TYPE SYNTAX INTEGER (0..128) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the fan pack specified exists or not." ::= { fanPackLEDsEntry 3 } ledFanPackError OBJECT-TYPE SYNTAX INTEGER (0..128) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the fan pack error LED is on or off." ::= { fanPackLEDsEntry 4 } -- ******************************************************************************** -- BCHT ONLY - Hardware Component Status LEDs -- ******************************************************************************** -- Media Tray Status LEDs -- ******************************************************************************** mtStatusLEDs OBJECT IDENTIFIER ::= { leds 7 } mtStatusLEDsTable OBJECT-TYPE SYNTAX SEQUENCE OF MtStatusLEDsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Media Tray Status LEDs information. NOTE: This MIB object is for BladeCenter HT only." ::= { mtStatusLEDs 1 } mtStatusLEDsEntry OBJECT-TYPE SYNTAX MtStatusLEDsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Media Tray Status LEDs information entry. NOTE: This MIB object is for BladeCenter HT only." INDEX { ledMediaTrayIndex } ::= { mtStatusLEDsTable 1 } MtStatusLEDsEntry ::= SEQUENCE { ledMediaTrayIndex INTEGER, ledMediaTrayId INTEGER, ledMediaTrayExists INTEGER, ledMediaTrayFault INTEGER } ledMediaTrayIndex OBJECT-TYPE SYNTAX INTEGER (0..128) ACCESS read-only STATUS mandatory DESCRIPTION "Media Tray Status LEDs table index. NOTE: This MIB object is for BladeCenter HT only." ::= { mtStatusLEDsEntry 1 } ledMediaTrayId OBJECT-TYPE SYNTAX INTEGER { topmediatray(1), botmediatray(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric Media Tray ID. NOTE: This MIB object is for BladeCenter HT only." ::= { mtStatusLEDsEntry 2 } ledMediaTrayExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the Media Tray exists or not. NOTE: This MIB object is for BladeCenter HT only." ::= { mtStatusLEDsEntry 3 } ledMediaTrayFault OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the Media Tray Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only." ::= { mtStatusLEDsEntry 5 } -- ******************************************************************************** -- Telco Alarm Panel Tray Status LEDs -- ******************************************************************************** tapStatusLEDs OBJECT IDENTIFIER ::= { leds 8 } tapExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the Alarm Panel exists or not. NOTE: This MIB object is for BladeCenter HT only." ::= { tapStatusLEDs 3 } tapFRRLED OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the Alarm Panel Safe To Remove LED is on or off. NOTE: This MIB object is for BladeCenter HT only." ::= { tapStatusLEDs 4 } tapFaultLED OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the Alarm Panel Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only." ::= { tapStatusLEDs 5 } -- ******************************************************************************** -- Network Clock Status LEDs -- ******************************************************************************** ncStatusLEDs OBJECT IDENTIFIER ::= { leds 9 } ncStatusLEDsTable OBJECT-TYPE SYNTAX SEQUENCE OF NcStatusLEDsEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Table of Network Clock Status LEDs information. NOTE: This MIB object is for BladeCenter HT only." ::= { ncStatusLEDs 1 } ncStatusLEDsEntry OBJECT-TYPE SYNTAX NcStatusLEDsEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Network Clock Status LEDs information entry. NOTE: This MIB object is for BladeCenter HT only." INDEX { ledNetworkClockIndex } ::= { ncStatusLEDsTable 1 } NcStatusLEDsEntry ::= SEQUENCE { ledNetworkClockIndex INTEGER, ledNetworkClockId INTEGER, ledNetworkClockExists INTEGER, ledNetworkClockFRR INTEGER, ledNetworkClockFault INTEGER } ledNetworkClockIndex OBJECT-TYPE SYNTAX INTEGER (0..128) ACCESS read-only STATUS deprecated DESCRIPTION "Network Clock Status LEDs table index. NOTE: This MIB object is for BladeCenter HT only." ::= { ncStatusLEDsEntry 1 } ledNetworkClockId OBJECT-TYPE SYNTAX INTEGER { networkclock1(1), networkclock2(2) } ACCESS read-only STATUS deprecated DESCRIPTION "The numeric Network Clock ID. NOTE: This MIB object is for BladeCenter HT only." ::= { ncStatusLEDsEntry 2 } ledNetworkClockExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Indicates whether the Network Clock exists or not. NOTE: This MIB object is for BladeCenter HT only." ::= { ncStatusLEDsEntry 3 } ledNetworkClockFRR OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Indicates whether the Network Clock Safe To Remove LED is on or off. NOTE: This MIB object is for BladeCenter HT only." ::= { ncStatusLEDsEntry 4 } ledNetworkClockFault OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Indicates whether the Network Clock Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only." ::= { ncStatusLEDsEntry 5 } -- ******************************************************************************** -- Multiplexer Expansion Module Status LEDs -- ******************************************************************************** mxStatusLEDs OBJECT IDENTIFIER ::= { leds 10 } mxStatusLEDsTable OBJECT-TYPE SYNTAX SEQUENCE OF MxStatusLEDsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Multiplexer Expansion Module Status LEDs information. NOTE: This MIB object is for BladeCenter HT only." ::= { mxStatusLEDs 1 } mxStatusLEDsEntry OBJECT-TYPE SYNTAX MxStatusLEDsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Multiplexer Expansion Module Status LEDs information entry. NOTE: This MIB object is for BladeCenter HT only." INDEX { ledMuxIndex } ::= { mxStatusLEDsTable 1 } MxStatusLEDsEntry ::= SEQUENCE { ledMuxIndex INTEGER, ledMuxId INTEGER, ledMuxExists INTEGER, ledMuxFRR INTEGER, ledMuxFault INTEGER } ledMuxIndex OBJECT-TYPE SYNTAX INTEGER (0..128) ACCESS read-only STATUS mandatory DESCRIPTION "Multiplexer Expansion Module Status LEDs table index. NOTE: This MIB object is for BladeCenter HT only." ::= { mxStatusLEDsEntry 1 } ledMuxId OBJECT-TYPE SYNTAX INTEGER { mux1(1), mux2(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric Multiplexer Expansion Module ID. NOTE: This MIB object is for BladeCenter HT only." ::= { mxStatusLEDsEntry 2 } ledMuxExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the Multiplexer Expansion Module exists or not. NOTE: This MIB object is for BladeCenter HT only." ::= { mxStatusLEDsEntry 3 } ledMuxFRR OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the Multiplexer Expansion Module Safe To Remove LED is on or off. NOTE: This MIB object is for BladeCenter HT only." ::= { mxStatusLEDsEntry 4 } ledMuxFault OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the Multiplexer Expansion Module Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only." ::= { mxStatusLEDsEntry 5 } -- ******************************************************************************** -- Storage LEDs -- ******************************************************************************** storageLEDs OBJECT IDENTIFIER ::= { leds 11 } storageLEDsTable OBJECT-TYPE SYNTAX SEQUENCE OF StorageLEDsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of storage module LEDs information. NOTE: This MIB object is for BladeCenter S only." ::= { storageLEDs 1 } storageLEDsEntry OBJECT-TYPE SYNTAX StorageLEDsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Storage Module LEDs information entry NOTE: This MIB object is for BladeCenter S only." INDEX { ledStorageIndex } ::= { storageLEDsTable 1 } StorageLEDsEntry ::= SEQUENCE { ledStorageIndex INTEGER, ledStorageId INTEGER, ledStorageExists INTEGER, ledStorageError INTEGER } ledStorageIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module LEDs table index. NOTE: This MIB object is for BladeCenter S only." ::= { storageLEDsEntry 1 } ledStorageId OBJECT-TYPE SYNTAX INTEGER { storage1(1), storage2(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric storage module ID. NOTE: This MIB object is for BladeCenter S only." ::= { storageLEDsEntry 2 } ledStorageExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the storage module specified exists or not. NOTE: This MIB object is for BladeCenter S only." ::= { storageLEDsEntry 3 } ledStorageError OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), blinking(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the status of the storage module error LED. NOTE: This MIB object is for BladeCenter S only." ::= { storageLEDsEntry 4 } -- ************************************************************************ -- BladeCenter T System Health -- ************************************************************************ telcoSystemHealth OBJECT IDENTIFIER ::= { monitors 9 } -- ************************************************************************ -- BladeCenter T System Health Status -- ************************************************************************ telcoSystemHealthStat OBJECT-TYPE SYNTAX INTEGER { critical-power(6), critical(5), major-power(4), major(3), minor-power(2), minor(1), normal(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates status of system health for the system in which the MM resides. Value of 'critical' indicates a non-recoverable service affecting condition has occurred that requires an immediate action. A value of 'major' indicates a critical service affecting condition has occurred that requires an urgent action. A value of 'minor' indicates a non-service affecting condition has occurred. Corrective action should be taken in order to prevent a more serious fault. A value of 'normal' indicates that the system is operating normally. Severity level with '-power' indicates the failure relates to the power resource. NOTE: This MIB object is for BladeCenter T only." ::= { telcoSystemHealth 1 } -- ************************************************************************ -- BladeCenter T System Health Summary -- ************************************************************************ telcoSystemHealthSummaryTable OBJECT-TYPE SYNTAX SEQUENCE OF TelcoSystemHealthSummaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of System Health summary. Contains more detailed information about the reasons for the overall system health status. NOTE: This MIB object is for BladeCenter T only. NOTE: This table may contain one entry if no alarms are in progress. That one entry, if present, contains no alarms but a message of 'Good' in the severity object." ::= { telcoSystemHealth 2 } telcoSystemHealthSummaryEntry OBJECT-TYPE SYNTAX TelcoSystemHealthSummaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "BladeCenter T System Health Summary entry. NOTE: This MIB object is for BladeCenter T only." INDEX { telcoSystemHealthSummaryIndex } ::= { telcoSystemHealthSummaryTable 1 } TelcoSystemHealthSummaryEntry ::= SEQUENCE { telcoSystemHealthSummaryIndex INTEGER, telcoSystemHealthSummarySeverity OCTET STRING, telcoSystemHealthSummaryDescription OCTET STRING, telcoSystemHealthSummaryEventName INTEGER, telcoSystemHealthSummaryEventKeyID OCTET STRING, telcoSystemHealthSummaryAcknowledge INTEGER, telcoSystemHealthSummaryAssertTime OCTET STRING } telcoSystemHealthSummaryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "BladeCenter T System Health Summary Index. NOTE: This MIB object is for BladeCenter T only." ::= { telcoSystemHealthSummaryEntry 1 } telcoSystemHealthSummarySeverity OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "BladeCenter T System Health Summary Severity. The values and meanings are as follows: 0x06 Critical-Power 0x05 Critical 0x04 Major-Power 0x03 Major 0x02 Minor-Power 0x01 Minor 0xFF Normal NOTE: This MIB object is for BladeCenter T only. NOTE: If no alarms are in progress, this object contains 'Good'." ::= { telcoSystemHealthSummaryEntry 2 } telcoSystemHealthSummaryDescription OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "BladeCenter T System Health Summary Description. NOTE: This MIB object is for BladeCenter T only. NOTE: If no alarms are in progress, this object contains 'No alarm events'." ::= { telcoSystemHealthSummaryEntry 3 } telcoSystemHealthSummaryEventName OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "BladeCenter T System Health Summary Event Name. NOTE: This MIB object is for BladeCenter T only." ::= { telcoSystemHealthSummaryEntry 4 } telcoSystemHealthSummaryEventKeyID OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "BladeCenter T System Health Summary Event Key ID. An octet string expressed as 'mmm:ggg:iii:aaa:sss' where: m : Module ID value of decimal digits(1-255) or blank space(s) for leading zero(s) g : Gen ID value of decimal digits(1-255) or blank space(s) for leading zero(s) i : GenInfo ID value of decimal digits(1-255) or blank space(s) for leading zero(s) a : Alarm ID value of decimal digits(1-255) or blank space(s) for leading zero(s) s : Alarm severity value of decimal digits(1-255) or blank space(s) for leading zero(s) NOTE: This MIB object is for BladeCenter T only. NOTE: If no alarms are in progress, this object contains 'No alarm events'." ::= { telcoSystemHealthSummaryEntry 5 } telcoSystemHealthSummaryAcknowledge OBJECT-TYPE SYNTAX INTEGER { unacknowledged(0), acknowledged(1) } ACCESS read-only STATUS mandatory DESCRIPTION "BladeCenter T System Health Summary Acknowledge. Indicates whether the alarm event is acknowledged or unacknowledged. NOTE: This MIB object is for BladeCenter T only." ::= { telcoSystemHealthSummaryEntry 6 } telcoSystemHealthSummaryAssertTime OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "BladeCenter T System Health Summary Assert Time. NOTE: This MIB object is for BladeCenter T only. NOTE: If no alarms are in progress, this object contains 'No alarm events'." ::= { telcoSystemHealthSummaryEntry 7 } -- ******************************************************************************** -- Fuel Gauge / Power Management -- ******************************************************************************** fuelGauge OBJECT IDENTIFIER ::= { monitors 10 } -- ******************************************************************************** -- Fuel Gauge -- ******************************************************************************** fuelGaugeInformation OBJECT IDENTIFIER ::= { fuelGauge 1 } fuelGaugeTable OBJECT-TYPE SYNTAX SEQUENCE OF FuelGaugeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Fuel Gauge information." ::= { fuelGaugeInformation 1 } fuelGaugeEntry OBJECT-TYPE SYNTAX FuelGaugeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Fuel Gauge entry" INDEX { fuelGaugeIndex } ::= { fuelGaugeTable 1 } FuelGaugeEntry ::= SEQUENCE { fuelGaugeIndex INTEGER, fuelGaugePowerDomainNumber INTEGER, fuelGaugeStatus OCTET STRING, fuelGaugeFirstPowerModule OCTET STRING, fuelGaugeSecondPowerModule OCTET STRING, fuelGaugePowerManagementPolicySetting INTEGER, fuelGaugeTotalPower OCTET STRING, fuelGaugeAllocatedPower OCTET STRING, fuelGaugeRemainingPower OCTET STRING, fuelGaugePowerInUsed OCTET STRING } fuelGaugeIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Fuel Gauge Table Index." ::= { fuelGaugeEntry 1 } fuelGaugePowerDomainNumber OBJECT-TYPE SYNTAX INTEGER { powerDomain1(1), powerDomain2(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Fuel Gauge Table Power Domain Number." ::= { fuelGaugeEntry 2 } fuelGaugeStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Fuel Gauge Table Status for the power domain. The response will start out with a numeric value (0 = unknown, 1 = good, 2 = warning, and 3: bad), followed by a text message." ::= { fuelGaugeEntry 3 } fuelGaugeFirstPowerModule OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Fuel Gauge Table First Power Module capacity in Watts in the power domain. NOTE: First power module in power domain 1 and 2 is in bay 1 and 3 respectively." ::= { fuelGaugeEntry 4 } fuelGaugeSecondPowerModule OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Fuel Gauge Table Second Power Module capacity in Watts in the power domain. NOTE: Second power module in power domain 1 and 2 is in bay 2 and 4 respectively." ::= { fuelGaugeEntry 5 } fuelGaugePowerManagementPolicySetting OBJECT-TYPE SYNTAX INTEGER { redundantWithoutPerformanceImpact(0), redundantWithPerformanceImpact(1), nonRedundant(2), redundantACPowerSource(3), acPowerSourceWithBladeThrottlingAllowed(4), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Fuel Gauge Table for the Power Management Policy Setting for each power domain. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. A new powerPolicyTable has been added which provides more detailed information regarding a domains power policy information. This table also has the capability to SET the power policy for a given domain. In addition, note that the first three enumerated choices above are referred to with updated nomenclature, as follows: redundantWithoutPerformanceImpact(0) equals Redundant Power Modules redundantWithPerformanceImpact(1) equals Power Modules with Blade Throttling Allowed nonRedundant(2) equals Basic Power Management" ::= { fuelGaugeEntry 6 } fuelGaugeTotalPower OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This field displays the total available power for each power domain based on installed power modules and the current Power Management Policy Setting. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored." ::= { fuelGaugeEntry 7 } fuelGaugeAllocatedPower OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This field displays the power that has been reserved in each power domain. NOTE: 1) Power is always reserved in domain 1 for two management modules and two I/O modules. 2) Power is reserved for I/O modules installed in bay 3 and 4 (Powered on or standby). 3) Power is reserved for each installed Blade. Blades in a standby state (not powered on) will reserve a certain amount power. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored." ::= { fuelGaugeEntry 8 } fuelGaugeRemainingPower OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This field displays the remaining power available in each domain. Remaining Power = Total Power minus Power In Use When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored." ::= { fuelGaugeEntry 9 } fuelGaugePowerInUsed OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This field displays the total power being used in each power domain. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored." ::= { fuelGaugeEntry 10 } -- ******************************************************************************** -- Fuel Gauge Power Domain 1 -- ******************************************************************************** powerDomain1 OBJECT IDENTIFIER ::= { fuelGauge 2 } powerDomain1Table OBJECT-TYPE SYNTAX SEQUENCE OF PowerDomain1Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Power Domain 1. NOTE: Blowers are also referred to as Chassis Cooling Devices. NOTE: Fan packs are also referred to as Power Module Cooling Devices." ::= { powerDomain1 1} powerDomain1Entry OBJECT-TYPE SYNTAX PowerDomain1Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Fuel Gauge entry" INDEX { pd1Index } ::= { powerDomain1Table 1 } PowerDomain1Entry ::= SEQUENCE { pd1Index INTEGER, pd1BayNumber OCTET STRING, pd1BladePrimarySlot INTEGER, pd1ModuleStatus INTEGER, pd1ModuleName OCTET STRING, pd1ModuleState INTEGER, pd1ModuleAllocatedPowerCurrent OCTET STRING, pd1ModuleAllocatedPowerMax OCTET STRING, pd1ModuleAllocatedPowerMin OCTET STRING, pd1ModuleCPUDutyCycles OCTET STRING, pd1ModuleThrottle INTEGER, pd1ModulePowerCapabilities INTEGER, pd1ModuleMeasuredOrStatic INTEGER } pd1Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 1 Table Index." ::= { powerDomain1Entry 1 } pd1BayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 1 Table Bay Number. The following Bay Number IDs are used in the BladeCenter: notApplicable(1), notApplicable(2), blowerBay1(3), blowerBay2(4), managementModuleBay1(5), managementModuleBay2(6), switchModuleBay1(7), switchModuleBay2(8), switchModuleBay3(9), switchModuleBay4(10), serverBladeBay1(11), serverBladeBay2(12), serverBladeBay3(13), serverBladeBay4(14), serverBladeBay5(15), serverBladeBay6(16), notApplicable(17) The following Bay Number IDs are used in the BladeCenter H: notApplicable(1), notApplicable(2), fanPackBay1(3), fanPackBay2(4), fanPackBay3(5), fanPackBay4(6), managementModuleBay1(7), managementModuleBay2(8), ioModuleBay1(9), ioModuleBay2(10), ioModuleBay3(11), ioModuleBay4(12), ioModuleBay7(13), ioModuleBay8(14), ioModuleBay9(15), ioModuleBay10(16), serverBladeBay1(17), serverBladeBay2(18), serverBladeBay3(19), serverBladeBay4(20), serverBladeBay5(21), serverBladeBay6(22), serverBladeBay7(23), notApplicable(24) The following Bay Number IDs are used in the BladeCenter T: notApplicable(1), notApplicable(2), blowerBay1(3), blowerBay2(4), blowerBay3(5) (if Power Domain 2 is not available), blowerBay4(6) (if Power Domain 2 is not available), managementModuleBay1(7), managementModuleBay2(8), switchModuleBay1(9), switchModuleBay2(10), switchModuleBay3(11), switchModuleBay4(12), serverBladeBay1(13), serverBladeBay2(14), serverBladeBay3(15), serverBladeBay4(16), notApplicable(17) The following Bay Number IDs are used in the BladeCenter HT: notApplicable(1), mediatrayBay1(2), mediatrayBay2(3), fanPackBay1(4), fanPackBay2(5), fanPackBay3(6), fanPackBay4(7), blowerBay1(8), blowerBay2(9), blowerBay3(10), blowerBay4(11), networkclockBay1(12), networkclockBay2(13), midplaneelectroBay1(14), midplaneelectroBay2(15), notApplicable(16), managementModuleBay1(17), managementModuleBay2(18), ioModuleBay1(19), ioModuleBay2(20), ioModuleBay3(21), ioModuleBay4(22), serverBladeBay1(23), serverBladeBay2(24), serverBladeBay3(25), serverBladeBay4(26), serverBladeBay5(27), serverBladeBay6(28), notApplicable(29) The following Bay Number IDs are used in the BladeCenter S: notApplicable(1), notApplicable(2), fanPackBay1(3), fanPackBay2(4), fanPackBay3(5), fanPackBay4(6), blowerBay1(7), blowerBay2(8), blowerBay3(9), blowerBay4(10), storageModuleBay1(11), storageModuleBay2(12), managementModuleBay(13), ioModuleBay1(14), ioModuleBay2(15), ioModuleBay3(16), ioModuleBay4(17), serverBladeBay1(18), serverBladeBay2(19), serverBladeBay3(20), serverBladeBay4(21), serverBladeBay5(22), serverBladeBay6(23), notApplicable(24)" ::= { powerDomain1Entry 2 } pd1BladePrimarySlot OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 1 Table Blade Primary Slot can be useful when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not." ::= { powerDomain1Entry 3 } pd1ModuleStatus OBJECT-TYPE SYNTAX INTEGER { insufficientPower(0), moduleIsThrottling(1), moduleNotThrottling(2), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 1 Table Module Throttle Status." ::= { powerDomain1Entry 4 } pd1ModuleName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 1 Table Module Name." ::= { powerDomain1Entry 5 } pd1ModuleState OBJECT-TYPE SYNTAX INTEGER { standby(0), on(1), notPresent(2), off(3), hibernate(4), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 1 Table Module State." ::= { powerDomain1Entry 6 } pd1ModuleAllocatedPowerCurrent OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 1 Table Allocated Power Current indicates the current power allocation for the module in Watts. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the current power allocation for the module is equally divided among the slots." ::= { powerDomain1Entry 7 } pd1ModuleAllocatedPowerMax OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 1 Table Allocated Power Max indicates the maximum power allocation for the module in Watts. It is indicative of the maximum amount of power the module will consume in the domain when it is fully populated with memory chips, expansion cards, etc. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the maximum power allocation for the module is equally divided among the slots." ::= { powerDomain1Entry 8 } pd1ModuleAllocatedPowerMin OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 1 Table Allocated Power Min indicates the minumum power allocation for the module in Watts. It is indicative of the minumum power consumption of the component in the domain based on its maximum throttle limit. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the minimum power allocation for the module is equally divided among the slots." ::= { powerDomain1Entry 9 } pd1ModuleCPUDutyCycles OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 1 Table Module CPUs Duty Cycles applies to blade servers only. It displays the duty cycle for each CPU on the blade as a percentage. Note that some blades do not report the CPU duty cycles. In this case, 'notApplicable' will be displayed. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: The CPU duty cycles are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The CPU duty cycles are reported on slot 3 while 'notApplicable' is displayed for slot 4." ::= { powerDomain1Entry 10 } pd1ModuleThrottle OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 1 Table Module Throttle indicates whether the server blade may be allowed to throttle or not. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored." ::= { powerDomain1Entry 11 } pd1ModulePowerCapabilities OBJECT-TYPE SYNTAX INTEGER { noAbility(0), staticPowerManagement(1), fixedPowerManagement(2), dynamicPowerManagement(3), dynamicPowerMeasurement1(4), dynamicPowerMeasurement2(5), dynamicPowerMeasurementWithPowerCapping(6), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 1 Table Module Power Capabilities. staticPowerManagement: the module with the static worst case power values. fixedPowermanagement: the module with the static power values but ability to throttle. dynamicPowerManagement: the module with power meter capability, measurement enabled, but capping disabled. dynamicPowerMeasurement1: the module with power meter capability, measurement enabled, phase 1 only dynamicPowerMeasurement2: the module with power meter capability, measurement enabled, phase 2 or higher dynamicPowerMeasurementWithPowerCapping: the module with power meter capability, both measurement and capping enabled, phase 2 or higher" ::= { powerDomain1Entry 12 } pd1ModuleMeasuredOrStatic OBJECT-TYPE SYNTAX INTEGER { static(0), measured(1), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 1 Table Module Measured Or Static." ::= { powerDomain1Entry 13 } powerDomain1PowerTrending OBJECT IDENTIFIER ::= { powerDomain1 3 } pd1PowerTrendingPeriod OBJECT-TYPE SYNTAX INTEGER { lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify time period for power domain 1 power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Power Domain." ::= { powerDomain1PowerTrending 1 } pd1PowerTrendingSampleTable OBJECT-TYPE SYNTAX SEQUENCE OF Pd1PowerTrendingSampleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Power Domain 1 Power Trending Information." ::= { powerDomain1PowerTrending 10 } pd1PowerTrendingSampleEntry OBJECT-TYPE SYNTAX Pd1PowerTrendingSampleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Power Domain 1 Power Trending Sample entry." INDEX { pd1PowerTrendingSampleIndex } ::= { pd1PowerTrendingSampleTable 1 } Pd1PowerTrendingSampleEntry ::= SEQUENCE { pd1PowerTrendingSampleIndex INTEGER, pd1PowerTrendingSampleTimeStamp OCTET STRING, pd1PowerTrendingSampleAve OCTET STRING } pd1PowerTrendingSampleIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 1 Power Trending Sample Table Index." ::= { pd1PowerTrendingSampleEntry 1 } pd1PowerTrendingSampleTimeStamp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 1 Power Trending Sample Table Timestamp." ::= { pd1PowerTrendingSampleEntry 2 } pd1PowerTrendingSampleAve OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 1 Power Trending Table Average Power." ::= { pd1PowerTrendingSampleEntry 3 } -- ******************************************************************************** -- Fuel Gauge Power Domain 2 -- ******************************************************************************** powerDomain2 OBJECT IDENTIFIER ::= { fuelGauge 3 } powerDomain2Table OBJECT-TYPE SYNTAX SEQUENCE OF PowerDomain2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Power Domain 2. NOTE: Blowers are also referred to as Chassis Cooling Devices. NOTE: Fan packs are also referred to as Power Module Cooling Devices." ::= { powerDomain2 1 } powerDomain2Entry OBJECT-TYPE SYNTAX PowerDomain2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Fuel Gauge entry" INDEX { pd2Index } ::= { powerDomain2Table 1 } PowerDomain2Entry ::= SEQUENCE { pd2Index INTEGER, pd2BayNumber OCTET STRING, pd2BladePrimarySlot INTEGER, pd2ModuleStatus INTEGER, pd2ModuleName OCTET STRING, pd2ModuleState INTEGER, pd2ModuleAllocatedPowerCurrent OCTET STRING, pd2ModuleAllocatedPowerMax OCTET STRING, pd2ModuleAllocatedPowerMin OCTET STRING, pd2ModuleCPUDutyCycles OCTET STRING, pd2ModuleThrottle INTEGER, pd2ModulePowerCapabilities INTEGER, pd2ModuleMeasuredOrStatic INTEGER } pd2Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 2 Table Index." ::= { powerDomain2Entry 1 } pd2BayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 2 Table Bay Number. The following Bay Number IDs are used in the BladeCenter: serverBladeBay7(1), serverBladeBay8(2), serverBladeBay9(3), serverBladeBay10(4), serverBladeBay11(5), serverBladeBay12(6), serverBladeBay13(7), serverBladeBay14(8), notApplicable(9) The following Bay Number IDs are used in the BladeCenter H: notApplicable(1), notApplicable(2), fanPackBay1(3), fanPackBay2(4), fanPackBay3(5), fanPackBay4(6), managementModuleBay1(7), managementModuleBay2(8), ioModuleBay1(9), ioModuleBay2(10), ioModuleBay3(11), ioModuleBay4(12), ioModuleBay7(13), ioModuleBay8(14), ioModuleBay9(15), ioModuleBay10(16), serverBladeBay8(17), serverBladeBay9(18), serverBladeBay10(19), serverBladeBay11(20), serverBladeBay12(21), serverBladeBay13(22), serverBladeBay14(23), notApplicable(24) The following Bay Number IDs are used in the BladeCenter T: blowerBay3(1), blowerBay4(2), serverBladeBay5(3), serverBladeBay6(4), serverBladeBay7(5), serverBladeBay8(6), notApplicable(7), notApplicable(8), notApplicable(9) The following Bay Number IDs are used in the BladeCenter HT: fanPackBay1(1), fanPackBay2(2), fanPackBay3(3), fanPackBay4(4), blowerBay1(5), blowerBay2(6), blowerBay3(7), blowerBay4(8), ioModuleBay7(9), ioModuleBay8(10), ioModuleBay9(11), ioModuleBay10(12), serverBladeBay7(13), serverBladeBay8(14), serverBladeBay9(15), serverBladeBay10(16), serverBladeBay11(17), serverBladeBay12(18), notApplicable(19)" ::= { powerDomain2Entry 2 } pd2BladePrimarySlot OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 2 Table Blade Primary Slot can be useful when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not." ::= { powerDomain2Entry 3 } pd2ModuleStatus OBJECT-TYPE SYNTAX INTEGER { insufficientPower(0), moduleIsThrottling(1), moduleNotThrottling(2), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 2 Table Module throttle status." ::= { powerDomain2Entry 4 } pd2ModuleName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 2 Table Module Name." ::= { powerDomain2Entry 5 } pd2ModuleState OBJECT-TYPE SYNTAX INTEGER { standby(0), on(1), notPresent(2), off(3), hibernate(4), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 2 Table Power State." ::= { powerDomain2Entry 6 } pd2ModuleAllocatedPowerCurrent OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 2 Table Allocated Power Current indicates the current power allocation for the module. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the current power allocation for the module is equally divided among the slots." ::= { powerDomain2Entry 7 } pd2ModuleAllocatedPowerMax OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 2 Table Allocated Power Max indicates the maximum power allocation for the module in Watts. It is indicative of the maximum amount of power the module will consume in the domain when it is fully populated with memory chips, expansion cards, etc. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the maximum power allocation for the module is equally divided among the slots." ::= { powerDomain2Entry 8 } pd2ModuleAllocatedPowerMin OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 2 Table Allocated Power Min indicates the minumum power allocation for the module in Watts. It is indicative of the minumum power consumption of the component in the domain based on its maximum throttle limit. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: When a server blade spans multiple slots (e.g. double wide or triple wide), the minimum power allocation for the module is equally divided among the slots." ::= { powerDomain2Entry 9 } pd2ModuleCPUDutyCycles OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 2 Table Module CPUs Duty Cycles applies to blade servers only. It displays the duty cycle for each CPU on the blade as a percentage. Note that some blades do not report the CPU duty cycles. In this case, 'notApplicable' will be displayed. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: The CPU duty cycles are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The CPU duty cycles are reported on slot 3 while 'notApplicable' is displayed for slot 4. " ::= { powerDomain2Entry 10 } pd2ModuleThrottle OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 2 Table Module Throttle indicates whether the server blade may be allowed to throttle or not. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored." ::= { powerDomain2Entry 11 } pd2ModulePowerCapabilities OBJECT-TYPE SYNTAX INTEGER { noAbility(0), staticPowerManagement(1), fixedPowerManagement(2), dynamicPowerManagement(3), dynamicPowerMeasurement1(4), dynamicPowerMeasurement2(5), dynamicPowerMeasurementWithPowerCapping(6), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 2 Table Module Power Capabilities. staticPowerManagement: the module with the static worst case power values. fixedPowermanagement: the module with the static power values but ability to throttle. dynamicPowerManagement: the module with power meter capability, measurement enabled, but capping disabled. dynamicPowerMeasurement1: the module with power meter capability, measurement enabled, phase 1 only dynamicPowerMeasurement2: the module with power meter capability, measurement enabled, phase 2 or higher dynamicPowerMeasurementWithPowerCapping: the module with power meter capability, both measurement and capping enabled, phase 2 or higher" ::= { powerDomain2Entry 12 } pd2ModuleMeasuredOrStatic OBJECT-TYPE SYNTAX INTEGER { static(0), measured(1), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 2 Table Module Measured Or Static." ::= { powerDomain2Entry 13 } powerDomain2PowerTrending OBJECT IDENTIFIER ::= { powerDomain2 3 } pd2PowerTrendingPeriod OBJECT-TYPE SYNTAX INTEGER { lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify time period for power domain 2 power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Power Domain." ::= { powerDomain2PowerTrending 1 } pd2PowerTrendingSampleTable OBJECT-TYPE SYNTAX SEQUENCE OF Pd2PowerTrendingSampleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Power Domain 2 Power Trending Sample Information." ::= { powerDomain2PowerTrending 10 } pd2PowerTrendingSampleEntry OBJECT-TYPE SYNTAX Pd2PowerTrendingSampleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Power Domain 2 Power Trending Sample entry." INDEX { pd2PowerTrendingSampleIndex } ::= { pd2PowerTrendingSampleTable 1 } Pd2PowerTrendingSampleEntry ::= SEQUENCE { pd2PowerTrendingSampleIndex INTEGER, pd2PowerTrendingSampleTimeStamp OCTET STRING, pd2PowerTrendingSampleAve OCTET STRING } pd2PowerTrendingSampleIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 2 Power Trending Sample Table Index." ::= { pd2PowerTrendingSampleEntry 1 } pd2PowerTrendingSampleTimeStamp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 2 Power Trending Sample Table Timestamp." ::= { pd2PowerTrendingSampleEntry 2 } pd2PowerTrendingSampleAve OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power Domain 2 Power Trending Sample Table Average Power." ::= { pd2PowerTrendingSampleEntry 3 } moduleInformation OBJECT IDENTIFIER ::= { fuelGauge 4 } bladeDetails OBJECT IDENTIFIER ::= { moduleInformation 1 } bladeDetailsTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeDetailsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Blade Module Details." ::= { bladeDetails 1} bladeDetailsEntry OBJECT-TYPE SYNTAX BladeDetailsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade Module Details entry." INDEX { bladeDetailsIndex } ::= { bladeDetailsTable 1 } BladeDetailsEntry ::= SEQUENCE { bladeDetailsIndex INTEGER, bladeDetailsId INTEGER, bladeDetailsMaxPowerConfig INTEGER, bladeDetailsEffectiveClockRate OCTET STRING, bladeDetailsMaximumClockRate OCTET STRING, bladeDetailsPowerSaverMode INTEGER, bladeDetailsDynamicPowerSaver INTEGER, bladeDetailsDynamicPowerFavorPerformanceOverPower INTEGER, bladeDetailsPowerControl INTEGER } bladeDetailsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade Module Details Table Index." ::= { bladeDetailsEntry 1 } bladeDetailsId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "Blade Module Details Table Blade Id." ::= { bladeDetailsEntry 2 } bladeDetailsMaxPowerConfig OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Blade Module Details Table Maximum Power Configuration. Allow the user to set the maximum power that can be used by the blade. This function is also known as power capping. If the value of maximum power config is zero, it means the blade doesn't support the power capping feature" ::= { bladeDetailsEntry 3 } bladeDetailsEffectiveClockRate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade Module Details Table Effective CPU Clock Rate applies to DPM blades only. It displays processor's effective clock rate based on sample interval. Note that some blades do not effective clock rate. In this case, 'notApplicable' will be displayed. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: The effective clock rate are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The effective clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4." ::= { bladeDetailsEntry 4 } bladeDetailsMaximumClockRate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade Module Details Table Maximum CPU Clock Rate applies to DPM blades only. It displays processor's maximum clock rate based on sample interval. Note that some blades do not maximum clock rate. In this case, 'notApplicable' will be displayed. When a 1200W or 1400W power module is installed in the domain the power management policy will not be applicable. In addition the power consumption in this domain will not be monitored. NOTE: The maximum clock rate are reported only on a primary slot when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not. The maximum clock rate are reported on slot 3 while 'notApplicable' is displayed for slot 4." ::= { bladeDetailsEntry 5 } bladeDetailsPowerSaverMode OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1), notApplicable(255) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled, the static low power saver mode allows the blade to selectively alter its operating voltage and frequency to reduce power consumption. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the static low power saver mode, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the static low power saver mode may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable bladeDetailsDynamicPowerSaver if its not already disabled." ::= { bladeDetailsEntry 6 } bladeDetailsDynamicPowerSaver OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1), notApplicable(255) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled, Dynamic Power Saver allows the voltage and frequency of the CPUs on the blade to be controlled based on how busy the CPU is. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power saver may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation. NOTE: enabling this object will disable bladeDetailsPowerSaverMode if its not already disabled." ::= { bladeDetailsEntry 7 } bladeDetailsDynamicPowerFavorPerformanceOverPower OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1), notApplicable(255) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled, Dynamic Power Favor Performance Over Power supports a max performance mode that pushes the system past its nominal CPU frequency when CPU and memory utilization implies it would help and the system allows it. Dynamic Power Performance Over Power can be active on the blade only after Dynamic Power Saver is enabled. This feature is not available on all blade types. Please refer to the blade documentation for details. If a blade does not support the dynamic power saver, this object will return notApplicable (255). Under certain rare circumstances, the enabling of the dynamic power favor performance over power may not complete successfully due to interactions with other blade functions, such as BIOS. Therefore, it is highly recommended that the user perform a GET of this object after performing a SET, in order to verify the completion of the intended operation." ::= { bladeDetailsEntry 8 } bladeDetailsPowerControl OBJECT-TYPE SYNTAX INTEGER { none(0), measurement(1), measurementpcap(2), psave(3), measurementpsave(4), measurementpcappsave(5), notApplicable(255) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to get or set the power control setting on a blade. If dynamic power mgmt is not supported on a blade, notApplicable(255) will be returned. This will set the power control setting on all slots of the multiwide blade. The same can be used if the blade is single wide." ::= { bladeDetailsEntry 9 } bladePowerTrending OBJECT IDENTIFIER ::= { bladeDetails 3 } bladePowerTrendingPeriod OBJECT-TYPE SYNTAX INTEGER { lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify time period for blade module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Blade Module." ::= { bladePowerTrending 1 } bladePowerTrendingBladeId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-write STATUS mandatory DESCRIPTION "Blade Module Power Trending Blade Id. NOTE: The Blade Id should be configured before displaying the bladePowerTrendingTable." ::= { bladePowerTrending 2 } bladePowerTrendingSampleTable OBJECT-TYPE SYNTAX SEQUENCE OF BladePowerTrendingSampleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Blade Module Power Trending Information." ::= { bladePowerTrending 10 } bladePowerTrendingSampleEntry OBJECT-TYPE SYNTAX BladePowerTrendingSampleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade Module Power Trending Sample entry." INDEX { bladePowerTrendingSampleIndex } ::= { bladePowerTrendingSampleTable 1 } BladePowerTrendingSampleEntry ::= SEQUENCE { bladePowerTrendingSampleIndex INTEGER, bladePowerTrendingSampleId INTEGER, bladePowerTrendingSampleTimeStamp OCTET STRING, bladePowerTrendingSampleMax OCTET STRING, bladePowerTrendingSampleMin OCTET STRING, bladePowerTrendingSampleAve OCTET STRING } bladePowerTrendingSampleIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade Module Power Trending Sample Table Index." ::= { bladePowerTrendingSampleEntry 1 } bladePowerTrendingSampleId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "Blade Module Power Trending Sample Table Blade Id." ::= { bladePowerTrendingSampleEntry 2 } bladePowerTrendingSampleTimeStamp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade Module Power Trending Sample Table Timestamp." ::= { bladePowerTrendingSampleEntry 3 } bladePowerTrendingSampleMax OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade Module Power Trending Sample Table Maximum Power." ::= { bladePowerTrendingSampleEntry 4 } bladePowerTrendingSampleMin OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade Module Power Trending Sample Table Minimum Power." ::= { bladePowerTrendingSampleEntry 5 } bladePowerTrendingSampleAve OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade Module Power Trending Sample Table Average Power." ::= { bladePowerTrendingSampleEntry 6 } switchDetails OBJECT IDENTIFIER ::= { moduleInformation 2 } switchPowerTrending OBJECT IDENTIFIER ::= { switchDetails 3 } switchPowerTrendingPeriod OBJECT-TYPE SYNTAX INTEGER { lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify time period for switch module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Switch Module." ::= { switchPowerTrending 1 } switchPowerTrendingSwitchId OBJECT-TYPE SYNTAX INTEGER { module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Switch Module Power Trending Switch Id. NOTE: The Switch Id should be configured before displaying the switchPowerTrendingTable." ::= { switchPowerTrending 2 } switchPowerTrendingSampleTable OBJECT-TYPE SYNTAX SEQUENCE OF SwitchPowerTrendingSampleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Switch Module Power Trending Information." ::= { switchPowerTrending 10 } switchPowerTrendingSampleEntry OBJECT-TYPE SYNTAX SwitchPowerTrendingSampleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module Power Trending Sample entry." INDEX { switchPowerTrendingSampleIndex } ::= { switchPowerTrendingSampleTable 1 } SwitchPowerTrendingSampleEntry ::= SEQUENCE { switchPowerTrendingSampleIndex INTEGER, switchPowerTrendingSampleId INTEGER, switchPowerTrendingSampleTimeStamp OCTET STRING, switchPowerTrendingSampleMax OCTET STRING, switchPowerTrendingSampleMin OCTET STRING, switchPowerTrendingSampleAve OCTET STRING } switchPowerTrendingSampleIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module Power Trending Sample Table Index." ::= { switchPowerTrendingSampleEntry 1 } switchPowerTrendingSampleId OBJECT-TYPE SYNTAX INTEGER { module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10) } ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module Power Trending Sample Table Switch Id." ::= { switchPowerTrendingSampleEntry 2 } switchPowerTrendingSampleTimeStamp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module Power Trending Sample Table Timestamp." ::= { switchPowerTrendingSampleEntry 3 } switchPowerTrendingSampleMax OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module Power Trending Sample Table Maximum Power." ::= { switchPowerTrendingSampleEntry 4 } switchPowerTrendingSampleMin OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module Power Trending Sample Table Minimum Power." ::= { switchPowerTrendingSampleEntry 5 } switchPowerTrendingSampleAve OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module Power Trending Sample Table Average Power." ::= { switchPowerTrendingSampleEntry 6 } blowerDetails OBJECT IDENTIFIER ::= { moduleInformation 3 } blowerPowerTrending OBJECT IDENTIFIER ::= { blowerDetails 3 } blowerPowerTrendingPeriod OBJECT-TYPE SYNTAX INTEGER { lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify time period for blower module power trending information table view. NOTE: This time period should be configured before displaying the following Power Trending Information table for Blower Module. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowerPowerTrending 1 } blowerPowerTrendingBlowerId OBJECT-TYPE SYNTAX INTEGER { blower1(1), blower2(2), blower3(3), blower4(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Blower Module Power Trending Blower Id. NOTE: The Blower Id should be configured before displaying the blowerPowerTrendingTable. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowerPowerTrending 2 } blowerPowerTrendingSampleTable OBJECT-TYPE SYNTAX SEQUENCE OF BlowerPowerTrendingSampleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Blower Module Power Trending Information. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowerPowerTrending 10 } blowerPowerTrendingSampleEntry OBJECT-TYPE SYNTAX BlowerPowerTrendingSampleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blower Module Power Trending Sample entry." INDEX { blowerPowerTrendingSampleIndex } ::= { blowerPowerTrendingSampleTable 1 } BlowerPowerTrendingSampleEntry ::= SEQUENCE { blowerPowerTrendingSampleIndex INTEGER, blowerPowerTrendingSampleId INTEGER, blowerPowerTrendingSampleTimeStamp OCTET STRING, blowerPowerTrendingSampleMax OCTET STRING, blowerPowerTrendingSampleMin OCTET STRING, blowerPowerTrendingSampleAve OCTET STRING } blowerPowerTrendingSampleIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blower Module Power Trending Sample Table Index." ::= { blowerPowerTrendingSampleEntry 1 } blowerPowerTrendingSampleId OBJECT-TYPE SYNTAX INTEGER { blower1(1), blower2(2), blower3(3), blower4(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Blower Module Power Trending Sample Table Blower Id." ::= { blowerPowerTrendingSampleEntry 2 } blowerPowerTrendingSampleTimeStamp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower Module Power Trending Sample Table Timestamp." ::= { blowerPowerTrendingSampleEntry 3 } blowerPowerTrendingSampleMax OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower Module Power Trending Sample Table Maximum Power." ::= { blowerPowerTrendingSampleEntry 4 } blowerPowerTrendingSampleMin OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower Module Power Trending Sample Table Minimum Power." ::= { blowerPowerTrendingSampleEntry 5 } blowerPowerTrendingSampleAve OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower Module Power Trending Sample Table Average Power." ::= { blowerPowerTrendingSampleEntry 6 } -- ****************************************************************************** -- Chassis Global Information -- ****************************************************************************** chassisInformation OBJECT IDENTIFIER ::= { fuelGauge 5 } chassisConfiguration OBJECT IDENTIFIER ::= { chassisInformation 1 } chassisTotalDCPowerAvailable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Chassis total DC power available, which displays the total DC power available for the entire chassis. It is the sum of the two power domains." ::= { chassisConfiguration 1 } chassisTotalACPowerInUsed OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Chassis total AC power being used, which displays the total AC power being consumed by all modules in the chassis. It also includes power consumed by the blowers (chassis oooling devices) for the chassis." ::= { chassisConfiguration 2 } chassisTotalThermalOutput OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Chassis total thermal output, which displays the thermal output (load) in BTUs per hour. It is calculated based on the total AC power in use. (1 Watt = 3.412 BTU/hour)." ::= { chassisConfiguration 3 } chassisTrendingSampleInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Chassis Power and Thermal Trending Sample Interval. 0 means no trending. the minimum interval is 10 minutes and the maximum is 60 minutes, in 5 minute increments." ::= { chassisConfiguration 4 } chassisPowerService OBJECT-TYPE SYNTAX INTEGER { volt110(1), volt220(2), notAvailable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "The chassis power service mode. NOTE: This MIB object is for BCS only." ::= { chassisConfiguration 5 } -- ****************************************************************************** -- Chassis Power Trending Information -- ****************************************************************************** chassisPowerTrending OBJECT IDENTIFIER ::= { chassisInformation 3 } chassisPowerTrendingPeriod OBJECT-TYPE SYNTAX INTEGER { lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify time period of power trending information. NOTE: This time period should be configured before displaying the following Power Trending Information table for Chassis." ::= { chassisPowerTrending 1 } chassisPowerTrendingSampleTable OBJECT-TYPE SYNTAX SEQUENCE OF ChassisPowerTrendingSampleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Chassis Power Trending Sample Information in specified time period." ::= { chassisPowerTrending 10 } chassisPowerTrendingSampleEntry OBJECT-TYPE SYNTAX ChassisPowerTrendingSampleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Chassis Power Trending Sample entry in specified time period." INDEX { chassisPowerTrendingSampleIndex } ::= { chassisPowerTrendingSampleTable 1 } ChassisPowerTrendingSampleEntry ::= SEQUENCE { chassisPowerTrendingSampleIndex INTEGER, chassisPowerTrendingSampleTimeStamp OCTET STRING, chassisPowerTrendingSampleAve OCTET STRING } chassisPowerTrendingSampleIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Chassis Power Trending Sample Index in specified time period." ::= { chassisPowerTrendingSampleEntry 1 } chassisPowerTrendingSampleTimeStamp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Chassis Power Trending Sample Timestamp in specified time period." ::= { chassisPowerTrendingSampleEntry 2 } chassisPowerTrendingSampleAve OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Chassis Power Trending Sample Average Power in specified time period." ::= { chassisPowerTrendingSampleEntry 3 } -- ****************************************************************************** -- Chassis Thermal Trending Information -- ****************************************************************************** chassisThermalTrending OBJECT IDENTIFIER ::= { chassisInformation 5 } chassisThermalTrendingPeriod OBJECT-TYPE SYNTAX INTEGER { lastHour(0), last6Hours(1), last12Hours(2), last24Hours(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify time period of thermal trending information. NOTE: This time period should be configured before displaying the following Thermal Trending Information table for Chassis." ::= { chassisThermalTrending 1 } mt1ThermalTrendingTable OBJECT-TYPE SYNTAX SEQUENCE OF Mt1ThermalTrendingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Media Tray 1 Thermal Trending Information." ::= { chassisThermalTrending 10 } mt1ThermalTrendingEntry OBJECT-TYPE SYNTAX Mt1ThermalTrendingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Media Tray 1 Thermal Trending entry." INDEX { mt1ThermalTrendingIndex } ::= { mt1ThermalTrendingTable 1 } Mt1ThermalTrendingEntry ::= SEQUENCE { mt1ThermalTrendingIndex INTEGER, mt1ThermalTrendingTimeStamp OCTET STRING, mt1ThermalTrendingTemperature OCTET STRING } mt1ThermalTrendingIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Media Tray 1 Thermal Trending Table Index." ::= { mt1ThermalTrendingEntry 1 } mt1ThermalTrendingTimeStamp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media Tray 1 Thermal Trending Table Sample Timestamp." ::= { mt1ThermalTrendingEntry 2 } mt1ThermalTrendingTemperature OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media Tray 1 Thermal Trending Table Temperature." ::= { mt1ThermalTrendingEntry 3 } mt2ThermalTrendingTable OBJECT-TYPE SYNTAX SEQUENCE OF Mt2ThermalTrendingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Media Tray 2 Thermal Trending Information. NOTE: This MIB object is for BladeCenter HT only." ::= { chassisThermalTrending 15 } mt2ThermalTrendingEntry OBJECT-TYPE SYNTAX Mt2ThermalTrendingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Media Tray 2 Thermal Trending entry. NOTE: This MIB object is for BladeCenter HT only." INDEX { mt2ThermalTrendingIndex } ::= { mt2ThermalTrendingTable 1 } Mt2ThermalTrendingEntry ::= SEQUENCE { mt2ThermalTrendingIndex INTEGER, mt2ThermalTrendingTimeStamp OCTET STRING, mt2ThermalTrendingTemperature OCTET STRING } mt2ThermalTrendingIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Media Tray 2 Thermal Trending Table Index. NOTE: This MIB object is for BladeCenter HT only." ::= { mt2ThermalTrendingEntry 1 } mt2ThermalTrendingTimeStamp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media Tray 2 Thermal Trending Table Sample Timestamp. NOTE: This MIB object is for BladeCenter HT only." ::= { mt2ThermalTrendingEntry 2 } mt2ThermalTrendingTemperature OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media Tray 2 Thermal Trending Table Temperature. NOTE: This MIB object is for BladeCenter HT only." ::= { mt2ThermalTrendingEntry 3 } blower1ThermalTrendingTable OBJECT-TYPE SYNTAX SEQUENCE OF Blower1ThermalTrendingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Blower 1 Thermal Trending Information. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { chassisThermalTrending 20} blower1ThermalTrendingEntry OBJECT-TYPE SYNTAX Blower1ThermalTrendingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blower 1 Thermal Trending entry." INDEX { blower1ThermalTrendingIndex } ::= { blower1ThermalTrendingTable 1 } Blower1ThermalTrendingEntry ::= SEQUENCE { blower1ThermalTrendingIndex INTEGER, blower1ThermalTrendingTimeStamp OCTET STRING, blower1ThermalTrendingTemperature OCTET STRING } blower1ThermalTrendingIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blower 1 Thermal Trending Table Index." ::= { blower1ThermalTrendingEntry 1 } blower1ThermalTrendingTimeStamp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower 1 Thermal Trending Table Sample Timestamp." ::= { blower1ThermalTrendingEntry 2 } blower1ThermalTrendingTemperature OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower 1 Thermal Trending Table Temperature." ::= { blower1ThermalTrendingEntry 3 } blower2ThermalTrendingTable OBJECT-TYPE SYNTAX SEQUENCE OF Blower2ThermalTrendingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Blower 2 Thermal Trending Information. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { chassisThermalTrending 30} blower2ThermalTrendingEntry OBJECT-TYPE SYNTAX Blower2ThermalTrendingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blower Thermal 2 Trending entry." INDEX { blower2ThermalTrendingIndex } ::= { blower2ThermalTrendingTable 1 } Blower2ThermalTrendingEntry ::= SEQUENCE { blower2ThermalTrendingIndex INTEGER, blower2ThermalTrendingTimeStamp OCTET STRING, blower2ThermalTrendingTemperature OCTET STRING } blower2ThermalTrendingIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blower 2 Thermal Trending Table Index." ::= { blower2ThermalTrendingEntry 1 } blower2ThermalTrendingTimeStamp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower 2 Thermal Trending Table Sample Timestamp." ::= { blower2ThermalTrendingEntry 2 } blower2ThermalTrendingTemperature OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower 2 Thermal Trending Table Temperature." ::= { blower2ThermalTrendingEntry 3 } blower3ThermalTrendingTable OBJECT-TYPE SYNTAX SEQUENCE OF Blower3ThermalTrendingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Blower 3 Thermal Trending Information. NOTE: This MIB object is for BladeCenter T only. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { chassisThermalTrending 40} blower3ThermalTrendingEntry OBJECT-TYPE SYNTAX Blower3ThermalTrendingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blower 3 Thermal Trending entry. NOTE: This MIB object is for BladeCenter T only." INDEX { blower3ThermalTrendingIndex } ::= { blower3ThermalTrendingTable 1 } Blower3ThermalTrendingEntry ::= SEQUENCE { blower3ThermalTrendingIndex INTEGER, blower3ThermalTrendingTimeStamp OCTET STRING, blower3ThermalTrendingTemperature OCTET STRING } blower3ThermalTrendingIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blower 3 Thermal Trending Table Index. NOTE: This MIB object is for BladeCenter T only." ::= { blower3ThermalTrendingEntry 1 } blower3ThermalTrendingTimeStamp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower 3 Thermal Trending Table Sample Timestamp. NOTE: This MIB object is for BladeCenter T only." ::= { blower3ThermalTrendingEntry 2 } blower3ThermalTrendingTemperature OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower 3 Thermal Trending Table Temperature. NOTE: This MIB object is for BladeCenter T only." ::= { blower3ThermalTrendingEntry 3 } blower4ThermalTrendingTable OBJECT-TYPE SYNTAX SEQUENCE OF Blower4ThermalTrendingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Blower 4 Thermal Trending Information. NOTE: This MIB object is for BladeCenter T only." ::= { chassisThermalTrending 50} blower4ThermalTrendingEntry OBJECT-TYPE SYNTAX Blower4ThermalTrendingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blower 4 Thermal Trending entry. NOTE: This MIB object is for BladeCenter T only. NOTE: Blowers are also referred to as Chassis Cooling Devices." INDEX { blower4ThermalTrendingIndex } ::= { blower4ThermalTrendingTable 1 } Blower4ThermalTrendingEntry ::= SEQUENCE { blower4ThermalTrendingIndex INTEGER, blower4ThermalTrendingTimeStamp OCTET STRING, blower4ThermalTrendingTemperature OCTET STRING } blower4ThermalTrendingIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blower 4 Thermal Trending Table Index. NOTE: This MIB object is for BladeCenter T only." ::= { blower4ThermalTrendingEntry 1 } blower4ThermalTrendingTimeStamp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower 4 Thermal Trending Table Sample Timestamp. NOTE: This MIB object is for BladeCenter T only." ::= { blower4ThermalTrendingEntry 2 } blower4ThermalTrendingTemperature OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower 4 Thermal Trending Table Temperature. NOTE: This MIB object is for BladeCenter T only." ::= { blower4ThermalTrendingEntry 3 } -- ******************************************************************************** -- Power Policy Table -- ******************************************************************************** powerPolicyInformation OBJECT IDENTIFIER ::= { fuelGauge 6 } powerPolicyTable OBJECT-TYPE SYNTAX SEQUENCE OF PowerPolicyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Power Policy information for all power domains. Reading this table can tell you about the available power policies that can be configured for a domain and also which is currently selected. The powerPolicyActivate object can also be SET to select which policy should be active for a given power domain." ::= { powerPolicyInformation 1 } powerPolicyEntry OBJECT-TYPE SYNTAX PowerPolicyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Power Policy Entry" INDEX { powerPolicyIndex } ::= { powerPolicyTable 1 } PowerPolicyEntry ::= SEQUENCE { powerPolicyIndex INTEGER, powerPolicyPowerDomainNumber INTEGER, powerPolicyName OCTET STRING, powerPolicyPwrSupplyFailureLimit INTEGER, powerPolicyMaxPowerLimit INTEGER, powerPolicyEstimatedUtilization INTEGER, powerPolicyActivate INTEGER } powerPolicyIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unique idenitifier of a row in the powerPolicyTable." ::= { powerPolicyEntry 1 } powerPolicyPowerDomainNumber OBJECT-TYPE SYNTAX INTEGER { powerDomain1(1), powerDomain2(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The power domain number which this row is associated with." ::= { powerPolicyEntry 2 } powerPolicyName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The short name of the power policy. The following are the possible names and their detailed description: Power Module Redundancy Intended for a single AC power source into the chassis where each Power Module is on its own dedicated circuit. Total allowed power draw is limited to one less than the number of Power Modules when more than one Power Module is present. One Power Module can fail without affecting blade operation. Multiple Power Module failures can cause the chassis to power off. Note that some blades may not be allowed to power on if doing so would exceed the policy power limit. Power Module Redundancy with Blade Throttling Allowed Very similar to the Power Module Redundancy policy. This policy allows you to draw more total power; however, capable blades may be allowed to throttle down if one Power Module fails. Basic Power Management Total allowed power is higher than other policies and is limited only by the total power capacity of all the Power Modules up to the maximum of chassis power rating. This is the least conservative approach, since it does not provide any protection for AC power source or Power Module failure. If any single power supply fails, blade and/or chassis operation may be affected. AC Power Source Redundancy Intended for dual AC power sources into the chassis. Total allowed power draw is limited to the capacity of two Power Modules. This is the most conservative approach and is recommended when all four Power Modules are installed. When the chassis is correctly wired with dual AC power sources, one AC power source can fail without affecting blade operation. Note that some blades may not be allowed to power on if doing so would exceed the policy power limit. AC Power Source Redundancy with Blade Throttling Allowed Very similar to the AC Power Source Redundancy policy. This policy allows you to draw more total power; however, capable blades may be allowed to throttle down if one AC power source fails." ::= { powerPolicyEntry 3 } powerPolicyPwrSupplyFailureLimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of power supplies that can fail in a chassis while still providing redundancy." ::= { powerPolicyEntry 4 } powerPolicyMaxPowerLimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum power available (in watts), based on the number of power modules and the Power Management Policy setting." ::= { powerPolicyEntry 5 } powerPolicyEstimatedUtilization OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The estimated utilization (as a percentage) based on current power usage." ::= { powerPolicyEntry 6 } powerPolicyActivate OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "When read, this object provides the status of this power policy. If the value is enabled(1), it means this is the active power policy for the associated domain. When set to a value of enabled(1), the power policy will be made the active one for the associated domain. A set of disabled(0) is not allowed. The SET may fail when the user goes from a less restrictive policy to a more restrictive policy, e.g. no power management to redundant power modules. This happens because the AMM might have allocated more power for components in the less restrictive policy. Then if a user wants to go to a more restrictive policy, the power available may be lower than what was already allocated. The SET should always succeed if a user goes from a more restrictive to a less restrictive policy." ::= { powerPolicyEntry 7 } -- ******************************************************************************** -- Error logs -- ******************************************************************************** eventLog OBJECT IDENTIFIER ::= { errorLogs 4 } readEventLogTable OBJECT-TYPE SYNTAX SEQUENCE OF ReadEventLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of event log entry information." ::= { eventLog 2 } readEventLogEntry OBJECT-TYPE SYNTAX ReadEventLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Event log table entry" INDEX { readEventLogIndex } ::= { readEventLogTable 1 } ReadEventLogEntry ::= SEQUENCE { readEventLogIndex INTEGER, readEventLogString OCTET STRING } readEventLogIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The event log index number. For consistent results, view as a table and not as individual entries." ::= { readEventLogEntry 1 } readEventLogString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string of data detailing an event. For consistent results, view as a table and not as individual entries." ::= { readEventLogEntry 2 } clearEventLog OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Clear the event log. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { eventLog 3 } monitorLogStateEvents OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "If disabled, it means the info LED will not turn on when the log gets full and no alerts will be sent out. If enabled, the LED will turn on when the log gets full and alerts will be sent out." ::= { eventLog 4 } readEnhancedEventLogTable OBJECT-TYPE SYNTAX SEQUENCE OF ReadEnhancedEventLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of enhanced event log entry information." ::= { eventLog 6 } readEnhancedEventLogEntry OBJECT-TYPE SYNTAX ReadEnhancedEventLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Enhaced Event log table entry, new entries could be added for new items." INDEX { readEnhancedEventLogNumber } ::= { readEnhancedEventLogTable 1 } ReadEnhancedEventLogEntry ::= SEQUENCE { readEnhancedEventLogNumber INTEGER, readEnhancedEventLogAttribute OCTET STRING, readEnhancedEventLogMessage OCTET STRING } readEnhancedEventLogNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The event log number for the enhanced event log. For consistent results, view as a table and not as individual entries." ::= { readEnhancedEventLogEntry 1 } readEnhancedEventLogAttribute OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string of data detailing an event log's attribute, such as the Event ID and Call Home Flag. The Event ID is a hexadecimal number representing an specific or class of events. The call home flag indicates that the corresponding problem may result in a call home. For consistent results, view as a table and not as individual entries." ::= { readEnhancedEventLogEntry 2} readEnhancedEventLogMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string of data detailing an event log message. For consistent results, view as a table and not as individual entries." ::= { readEnhancedEventLogEntry 3} readAuditLogTable OBJECT-TYPE SYNTAX SEQUENCE OF ReadAuditLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of audit log entry information. Audit log includes the logs whose source is 'Audit'" ::= { eventLog 10 } readAuditLogEntry OBJECT-TYPE SYNTAX ReadAuditLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Audit log table entry, new entries could be added for new items." INDEX { readAuditLogNumber } ::= { readAuditLogTable 1 } ReadAuditLogEntry ::= SEQUENCE { readAuditLogNumber INTEGER, readAuditLogAttribute OCTET STRING, readAuditLogMessage OCTET STRING } readAuditLogNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The audit log number. For consistent results, view as a table and not as individual entries." ::= { readAuditLogEntry 1 } readAuditLogAttribute OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string of data detailing an audit eventlog's attribute. For consistent results, view as a table and not as individual entries." ::= { readAuditLogEntry 2 } readAuditLogMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string of data detailing an audit event log message. For consistent results, view as a table and not as individual entries." ::= { readAuditLogEntry 3 } clearAuditLog OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Clear the audit log. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { eventLog 11 } readSystemLogTable OBJECT-TYPE SYNTAX SEQUENCE OF ReadSystemLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of system log entry information. System log includes the logs whose source is other than 'Audit'" ::= { eventLog 12 } readSystemLogEntry OBJECT-TYPE SYNTAX ReadSystemLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "System log table entry, new entries could be added for new items." INDEX { readSystemLogNumber } ::= { readSystemLogTable 1 } ReadSystemLogEntry ::= SEQUENCE { readSystemLogNumber INTEGER, readSystemLogAttribute OCTET STRING, readSystemLogMessage OCTET STRING } readSystemLogNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The system log index number. For consistent results, view as a table and not as individual entries." ::= { readSystemLogEntry 1 } readSystemLogAttribute OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string of data detailing an system event log's attribute. For consistent results, view as a table and not as individual entries." ::= { readSystemLogEntry 2 } readSystemLogMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string of data detailing an system event log message. For consistent results, view as a table and not as individual entries." ::= { readSystemLogEntry 3 } clearSystemLog OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Clear the system log. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { eventLog 13 } -- ******************************************************************************** -- Configure the MM -- ******************************************************************************** -- ******************************************************************************** -- Remote Access Configuration -- ******************************************************************************** remoteAccessConfig OBJECT IDENTIFIER ::= { configureSP 1 } -- ******************************************************************************** -- General Remote Access and Remote Alerts Configuration -- ******************************************************************************** generalRemoteCfg OBJECT IDENTIFIER ::= { remoteAccessConfig 1 } remoteAlertRetryDelay OBJECT-TYPE SYNTAX INTEGER { noDelay(0), -- deprecated oneHalfMinute(30), oneMinute(60), oneAndHalfMinutes(90), twoMinutes(120), twoAndHalfMinutes(150), threeMinutes(180), threeAndHalfMinutes(210), fourMinutes(240) } ACCESS read-write STATUS mandatory DESCRIPTION "Number in seconds to delay between retries if sending a remote alert is unsuccessful." ::= { generalRemoteCfg 3 } remoteAlertRetryCount OBJECT-TYPE SYNTAX INTEGER { noretry(0), retry1(1), retry2(2), retry3(3), retry4(4), retry5(5), retry6(6), retry7(7), retry8(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Number of additional times a remote alert will be retried if not successfully sent. A value of zero indicates no retries will be attempted." ::= { generalRemoteCfg 4 } remoteAlertEntryDelay OBJECT-TYPE SYNTAX INTEGER { noDelay(0), oneHalfMinute(30), oneMinute(60), oneAndHalfMinutes(90), twoMinutes(120), twoAndHalfMinutes(150), threeMinutes(180), threeAndHalfMinutes(210), fourMinutes(240) } ACCESS read-only STATUS deprecated DESCRIPTION "Number in seconds to delay between entries if sending a remote alert is unsuccessful. NOTE: This object is no longer supported. However, for compatibilities sake, a value of (255) is returned when read. Also, write access has been removed." ::= { generalRemoteCfg 5 } remoteAccessTamperDelay OBJECT-TYPE SYNTAX INTEGER { nowait(0), oneMinute(1), twoMinutes(2), threeMinutes(3), fourMinutes(4), fiveMinutes(5), sixMinutes(6), sevenMinutes(7), tenMinutes(10), fifteenMinutes(15), twentyMinutes(20), thirtyMinutes(30), sixtyMinutes(60), oneTwentyMinutes(120), oneEightyMinutes(180), twoFortyMinutes(240) } ACCESS read-write STATUS deprecated DESCRIPTION "This value is no longer supported and has been replaced by 'lockoutPeriod'." ::= { generalRemoteCfg 6 } userAuthenticationMethod OBJECT-TYPE SYNTAX INTEGER { localOnly(0), ldapOnly(1), localFirstThenLdap(2), ldapFirstThenLocal(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Use this field to specify how users attempting to login should be authenticated. There are two methods: Local authentication. Userid and password are verified by searching the list of users locally configured under Local Login Profiles. LDAP based authentication. Users are authenticated via a remote LDAP server. One or both authentication methods can be selected. If both methods should be used, the order must be specified." ::= { generalRemoteCfg 7 } maxSessionsPerLDAPUser OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of simultaneous active sessions allowed for each LDAP user. If the value is 0, this option is disabled. The minimum value is 1 and the maximum value is 20." ::= { generalRemoteCfg 9 } authenticationLoggingTimeout OBJECT-TYPE SYNTAX INTEGER { logAll(0), fiveSeconds(1), thirtySeconds(2), oneMinute(3), fiveMinutes(4), tenMinutes(5), thirtyMinutes(6), oneHour(7), twelveHours(8), oneDay(9), logNone(255) } ACCESS read-write STATUS mandatory DESCRIPTION "Use this option to set how long, in seconds, AMM will not log the authentication events for the same user. The default setting is 5 minutes. 0 indicates log all authentication events, 255 indicates don't log any new authentication events." ::= { generalRemoteCfg 10 } trackingIP OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This option indicates tracking different IP addresses for the same user is enabled or not. If it is enabled then an access every second from alternating IP addresses will result in multiple log entries, regardless of the time duration set in the 'authenticaionLoggingTimeout'field. If this flag is disabled, multiple accesses by varying IP addresses will only be logged as 'new' accesses if they are out of the 'authenticationLoggingTimeout'." ::= { generalRemoteCfg 11 } -- ******************************************************************************** -- Account security management -- ******************************************************************************** accountSecurityManagement OBJECT IDENTIFIER ::= { generalRemoteCfg 20 } accountSecurityLevel OBJECT-TYPE SYNTAX INTEGER { legacy(0), high(1), custom(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The level of security needed for local user login passwords. The legacy level: - no password required - no password expiration - no password re-use restrictions - no frequency of password change restrictions - account is locked for 2 minutes after 5 login failures - simple password rules - no account inactivity monitoring The high level: - password required - factory default 'USERID' account password must be changed on next login - force user to change password on first login - password expires in 90 days - password re-use checking enabled (last 5 passwords kept in history) - minimum 24 hours interval between password changes - account is locked for 60 minutes after 5 login failures - complex password rules with 2 degrees of difference from previous password - alert on account inactivity after 120 days - accounts disabled after 180 days of inactivity The custom level: - set the password settings individually under customSecuritySettings The default value is legacy." ::= { accountSecurityManagement 1 } customSecuritySettings OBJECT IDENTIFIER ::= { accountSecurityManagement 2 } loginPasswordRequired OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "If enabled, all users require a login password to access the AMM. If disabled, empty password is allowed and complex password rules will be disabled automatically. The default value is disabled." ::= { customSecuritySettings 1 } passwordExpirationPeriod OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of days before login passwords expire. The minimum value is 1 day and the maximum value is 365 days. The default value is 90 days. A value of 0 disables this option." ::= { customSecuritySettings 2 } defaultAdminPasswordExpired OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "If enabled, the factory default 'USERID' account password must be changed on next login. The default value is disabled." ::= { customSecuritySettings 3 } minimumPasswordReuseCycle OBJECT-TYPE SYNTAX INTEGER { none(0), onePassword(1), twoPasswords(2), threePasswords(3), fourPasswords(4), fivePasswords(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of unique passwords a user must choose before reusing a password. The default value is none." ::= { customSecuritySettings 4 } complexPasswordRules OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "If enabled, the minimum complexity rules will be enforced for all local login passwords and 'User login password required' rule will be enabled. The rules are as follows: Passwords must be a minimum of eight characters. Passwords must not be a repeat or reverse of the associated login id. Passwords must be no more than three of the same characters used consecutively. Passwords must contain at least three of the following combinations: At least one lower case alphanumeric character. At least one upper case alphanumeric character. At least one numeric character. At least one special character. The default value is disabled." ::= { customSecuritySettings 5 } minimumDiffCharsPassword OBJECT-TYPE SYNTAX INTEGER { none(0), oneChar(1), twoChars(2), threeChars(3), fourChars(4), fiveChars(5), sixChars(6), sevenChars(7), eightChars(8), nineChars(9), tenChars(10), elevenChars(11), twelveChars(12), thirteenChars(13), fourteenChars(14), fifteenChars(15) } ACCESS read-write STATUS mandatory DESCRIPTION "The required minimum number of characters in the new password different from the previous password. The default value is 2. A SET of this object is ignored until the complexPasswordRules option is enabled and the minimumPasswordReuseCycle is not none(0)" ::= { customSecuritySettings 6 } changePasswordFirstAccess OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "If enabled, the login user will be forced to change their password on the first access after the account has been established or on the first access after an administrator has changed the password for the user, except for the administrator password for USERID. The default value is disabled." ::= { customSecuritySettings 7 } inactivityAlertPeriod OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The period of time in days before generating an alert for a dormant account. This value applies to all login accounts, including the administrator account. The minimum value is 1 day and the maximum value is 365 days. The default value is 0 which disables this option. NOTE: This value must be less than the inactivityAlertDisablePeriod." ::= { customSecuritySettings 8 } inactivityAlertDisablePeriod OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The period of time in days before generating an alert and disabling a dormant account. This value applies to all login accounts, excluding the administrator account. The minimum value is 1 day and the maximum value is 365 days. The default value is 0 which disables this option. NOTE: This value must be greater than the inactivityAlertPeriod." ::= { customSecuritySettings 9 } lockoutPeriod OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The period of time in minutes that a user is locked out after the maximum number of login failures was reached. The minimum value is is 1 minute and the maximum value is 2880 minutes. The default value is 2 minutes for the Legacy security level and 60 minutes for the High security level. A value of 0 disables this option." ::= { customSecuritySettings 10 } maxLoginFailures OBJECT-TYPE SYNTAX INTEGER { none(0), oneTime(1), twoTimes(2), threeTimes(3), fourTimes(4), fiveTimes(5), sixTimes(6), sevenTimes(7), eightTimes(8), nineTimes(9), tenTimes(10) } ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of login failures before a user account is locked. A value of 0 disables this option. The default value is 5." ::= { customSecuritySettings 11 } passwordChangeInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A minimum period of time that user is not able to change their own password. The range of acceptable values will be from 0 to 1440 (or 60 days). A value of 0 disables this option. If the password expiration period is set, it must be greater than the minimum password change interval." ::= { customSecuritySettings 12 } -- *********************************************************************** -- Serial Port Configuration -- *********************************************************************** serialPortCfg OBJECT IDENTIFIER ::= { remoteAccessConfig 2 } portBaud OBJECT-TYPE SYNTAX INTEGER { baud2400(0), baud4800(1), baud9600(3), baud19200(7), baud38400(15), baud57600(23) } ACCESS read-write STATUS mandatory DESCRIPTION "Baud rate for the serial port." ::= { serialPortCfg 1 } portParity OBJECT-TYPE SYNTAX INTEGER { none(0), odd(1), even(3), mark(5), space(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Parity setting for the serial port." ::= { serialPortCfg 2 } portStopBits OBJECT-TYPE SYNTAX INTEGER { oneStopbit(0), twoOrOnePtFive(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Number of stop bits for the serial port." ::= { serialPortCfg 3 } -- ******************************************************************************** -- Remote Alert Profiles -- ******************************************************************************** remoteAlertIds OBJECT IDENTIFIER ::= { remoteAccessConfig 3 } remoteAlertIdsTable OBJECT-TYPE SYNTAX SEQUENCE OF RemoteAlertIdsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of remote alert entries. This table lets you configure remote alert recipients. You can define up to 12 unique recipients. NOTE: All selected alert events will be sent to all enabled alert recipients." ::= { remoteAlertIds 1 } remoteAlertIdsEntry OBJECT-TYPE SYNTAX RemoteAlertIdsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Remote alert entries." INDEX { remoteAlertIdEntryIndex } ::= { remoteAlertIdsTable 1 } RemoteAlertIdsEntry ::= SEQUENCE { remoteAlertIdEntryIndex INTEGER, remoteAlertIdEntryStatus INTEGER, remoteAlertIdEntryIpOrHostAddress OCTET STRING, remoteAlertIdEntryTextDescription OCTET STRING, remoteAlertIdEntryNotificationType INTEGER, remoteAlertIdEmailAddr OCTET STRING, remoteAlertIdEntrySelectiveAlert INTEGER } remoteAlertIdEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index for remote alert entry." ::= { remoteAlertIdsEntry 1 } remoteAlertIdEntryStatus OBJECT-TYPE SYNTAX INTEGER { invalid(0), disabledAndValid(1), enabledAndValid(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Remote alert entry status, invalid means entry not defined yet, disabledAndValid means entry defined but not enabled to send an alert, enabledAndValid means entry defined and enabled to send an alert." ::= { remoteAlertIdsEntry 2 } remoteAlertIdEntryIpOrHostAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..50)) ACCESS read-write STATUS mandatory DESCRIPTION "A null terminated string that either contains an IP address of the form '1.2.3.4' or a host name (if DNS is enabled) for the alert entry." ::= { remoteAlertIdsEntry 3 } remoteAlertIdEntryTextDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..50)) ACCESS read-write STATUS mandatory DESCRIPTION "A null terminated string that contains a text description of this entry." ::= { remoteAlertIdsEntry 4 } remoteAlertIdEntryNotificationType OBJECT-TYPE SYNTAX INTEGER { unknown(0), ibmDirectorOverLAN(8), snmpOverLan(4), emailOverLan(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Remote alert entry notification method. Types include unknown when the type can't be determined (read-only), ibmDirectorOverLAN for a LAN alert sent over ethernet to IBM director, snmpOverLan for an SNMP alert over ethernet, and emailOverLan for a E-Mail alert over ethernet." ::= { remoteAlertIdsEntry 5 } remoteAlertIdEmailAddr OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "A null terminated string that contains an E-Mail Address. For example, 'jeb@us.ibm.com'. Used only for an E-mail over LAN or E-Mail over PPP notification type." ::= { remoteAlertIdsEntry 9 } remoteAlertIdEntrySelectiveAlert OBJECT-TYPE SYNTAX INTEGER { critOnlyAlerts(0), allAlerts(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Remote alert entry selective alert setting. A value of critOnlyAlerts will only send critical alerts to this remote alert recipient, a value of allAlerts will send all alerts to this remote alert recipient." ::= { remoteAlertIdsEntry 13 } generateTestAlert OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate a Test Alert. This will send a test alert to all configured and enabled remote alert recipients. The text portion of the alert will contain 'Application Posted Alert to MM'. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { remoteAlertIds 30 } -- ******************************************************************************** -- Remote Access Profiles -- ******************************************************************************** remoteAccessIds OBJECT IDENTIFIER ::= { remoteAccessConfig 4 } remoteAccessIdsTable OBJECT-TYPE SYNTAX SEQUENCE OF RemoteAccessIdsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of remote access profiles. This table lets you to configure all login profiles. You can define up to 12 unique profiles. NOTE: By default, the management module comes configured with one login profile that allows remote access using a login ID of 'USERID' and a password of 'PASSW0RD' (the 0 is a zero). To avoid a potential security exposure, we strongly recommend that you change this default Login Profile to values of your choice." ::= { remoteAccessIds 1 } remoteAccessIdsEntry OBJECT-TYPE SYNTAX RemoteAccessIdsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Remote access entries." INDEX { remoteAccessIdEntryIndex } ::= { remoteAccessIdsTable 1 } RemoteAccessIdsEntry ::= SEQUENCE { remoteAccessIdEntryIndex INTEGER, remoteAccessIdEntryUserId OCTET STRING, remoteAccessIdEntryPassword OCTET STRING, remoteAccessIdEntryEncodedLoginPw OCTET STRING, remoteAccessIdEntryRole OCTET STRING, remoteAccessIdEntryLoggedIn INTEGER, remoteAccessIdEntryLastLogin OCTET STRING, remoteAccessIdEntryPwdCompliant INTEGER, remoteAccessIdEntryPwdExp OCTET STRING, remoteAccessIdEntryDormant INTEGER, remoteAccessIdEntryState INTEGER, remoteAccessIdEntryAction INTEGER, remoteAccessIdEntrySessionCount INTEGER, remoteAccessIdEntryMaxSessions INTEGER } remoteAccessIdEntryIndex OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Index for Remote access entry." ::= { remoteAccessIdsEntry 1 } remoteAccessIdEntryUserId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "Remote access entry null terminated string that contains the user-id. It must not be a duplicate of any previously configured ones." ::= { remoteAccessIdsEntry 2 } remoteAccessIdEntryPassword OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "Remote access password. The password must contain at least one alphabetic and one non-alphabetic character and be at least 5 characters long, or you can leave the password field blank to set an empty password. NOTE: Value returned by the GET command is meaningless for this MIB object." ::= { remoteAccessIdsEntry 3 } remoteAccessIdEntryEncodedLoginPw OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..36)) ACCESS read-write STATUS deprecated DESCRIPTION "Used only for configuration save/restore. A null terminated string containing an encoded concatenation of the login ID and password separated by an ':'. This object is no longer supported and will return a string of asterisks" ::= { remoteAccessIdsEntry 7 } remoteAccessIdEntryRole OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if user has supervisor, operator, or custom access." ::= { remoteAccessIdsEntry 10 } remoteAccessIdEntryLoggedIn OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if user is currently logged in or not." ::= { remoteAccessIdsEntry 11 } remoteAccessIdEntryLastLogin OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Timestamp for the last successful login by the user." ::= { remoteAccessIdsEntry 12 } remoteAccessIdEntryPwdCompliant OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if user complies with all of the password rules currently in effect." ::= { remoteAccessIdsEntry 13 } remoteAccessIdEntryPwdExp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The number of days until the user's current password expires." ::= { remoteAccessIdsEntry 14 } remoteAccessIdEntryDormant OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if the user account has been inactive for a specified amount of time based on inactivityAlertDisablePeriod in the customSecuritySettings section." ::= { remoteAccessIdsEntry 15 } remoteAccessIdEntryState OBJECT-TYPE SYNTAX INTEGER { disabled(0), active(1), locked(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the state of the user: Active - normal state Disabled - user cannot use account until enabled by a supervisor or chassis user account manager. An account can get disabled after being dormant for a specified amount of time OR as a result of a supervisor or chassis user account manager disabling it. Locked - account is temporarily locked due to repeated unsuccessful login attempts as specified by lockoutPeriod in the customSecuritySettings section. Account can be unlocked by a supervisor or chassis user account manager OR can be automatically unlocked after the lockoutPeriod expires. NOTE: The disable action does not apply to supervisor or chassis user account manager accounts." ::= { remoteAccessIdsEntry 16 } remoteAccessIdEntryAction OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1), unlock(2), notApplicable(255) } ACCESS read-write STATUS mandatory DESCRIPTION "Actions that only a supervisor or chassis user account manager can perform for each user id: Enable - enables an account in the Disabled state Disable - disables an account in the Active or Locked state Unlock - unlock an account in the Locked state NOTE: The disable action does not apply to supervisor or chassis user account manager accounts. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { remoteAccessIdsEntry 17 } remoteAccessIdEntrySessionCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of sessions the user is currently logged in to." ::= { remoteAccessIdsEntry 18 } remoteAccessIdEntryMaxSessions OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of simultaneous active sessions allowed for the user. If the value is 0, this option is disabled. The minimum value is 1 and the maximum value is 20." ::= { remoteAccessIdsEntry 19 } -- ******************************************************************************** remoteAccessUserAuthorityLevelTable OBJECT-TYPE SYNTAX SEQUENCE OF RemoteAccessUserAuthorityLevelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of user authority level profiles." ::= { remoteAccessIds 2 } remoteAccessUserAuthorityLevelEntry OBJECT-TYPE SYNTAX RemoteAccessUserAuthorityLevelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "User authority level entries." INDEX { ualIndex } ::= { remoteAccessUserAuthorityLevelTable 1 } RemoteAccessUserAuthorityLevelEntry ::= SEQUENCE { ualIndex INTEGER, ualId OCTET STRING, ualSupervisor INTEGER, ualReadOnly INTEGER, ualAccountManagement INTEGER, ualConsoleAccess INTEGER, ualConsoleAndVirtualMediaAccess INTEGER, ualServerPowerAccess INTEGER, ualAllowClearLog INTEGER, ualAdapterBasicConfig INTEGER, ualAdapterNetworkAndSecurityConfig INTEGER, ualAdapterAdvancedConfig INTEGER } ualIndex OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Index for User Authority Level entry." ::= { remoteAccessUserAuthorityLevelEntry 1 } ualId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "User ID" ::= { remoteAccessUserAuthorityLevelEntry 2 } ualSupervisor OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has no restrictions." ::= { remoteAccessUserAuthorityLevelEntry 3 } ualReadOnly OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has only read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, etc.)." ::= { remoteAccessUserAuthorityLevelEntry 4 } ualAccountManagement OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User can add/modify/delete users and change the global login settings in the Login Profiles panel." ::= { remoteAccessUserAuthorityLevelEntry 5 } ualConsoleAccess OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User can access the remote console." ::= { remoteAccessUserAuthorityLevelEntry 6 } ualConsoleAndVirtualMediaAccess OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User can access both the remote console and the virtual media feature." ::= { remoteAccessUserAuthorityLevelEntry 7 } ualServerPowerAccess OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User can access the power on and restart functions for the remote server. These functions are available via the Power/Restart panel." ::= { remoteAccessUserAuthorityLevelEntry 8 } ualAllowClearLog OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User can clear the event logs. Everyone can look at the event logs, but this particular permission is required to clear the logs." ::= { remoteAccessUserAuthorityLevelEntry 9 } ualAdapterBasicConfig OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User can modify configuration parameters in the System Settings and Alerts panels." ::= { remoteAccessUserAuthorityLevelEntry 10 } ualAdapterNetworkAndSecurityConfig OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User can modify configuration parameters in the Security, Network Protocols, Network Interface, Port Assignments, and Serial Port panels." ::= { remoteAccessUserAuthorityLevelEntry 11 } ualAdapterAdvancedConfig OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has no restrictions when configuring the adapter. In addition, the user is said to have administrative access to the RSA, meaning that the user can also perform the following advanced functions: firmware upgrades, PXE network boot, restore adapter factory defaults, modify and restore adapter configuration from a configuration file, and restart/reset the adapter." ::= { remoteAccessUserAuthorityLevelEntry 12 } remoteAccessRBSroleTable OBJECT-TYPE SYNTAX SEQUENCE OF RemoteAccessRBSroleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of RBS User Role profiles." ::= { remoteAccessIds 3 } remoteAccessRBSroleEntry OBJECT-TYPE SYNTAX RemoteAccessRBSroleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "User Role entries." INDEX { roleIndex } ::= { remoteAccessRBSroleTable 1 } RemoteAccessRBSroleEntry ::= SEQUENCE { roleIndex INTEGER, roleId OCTET STRING, rbsSupervisor INTEGER, rbsOperator INTEGER, rbsChassisOperator INTEGER, rbsChassisAccountManagement INTEGER, rbsChassisLogManagement INTEGER, rbsChassisConfiguration INTEGER, rbsChassisAdministration INTEGER, rbsBladeOperator INTEGER, rbsBladeRemotePresence INTEGER, rbsBladeConfiguration INTEGER, rbsBladeAdministration INTEGER, rbsSwitchModuleOperator INTEGER, rbsSwitchModuleConfiguration INTEGER, rbsSwitchModuleAdministration INTEGER, rbsBladeRemotePresenseVideo INTEGER, -- deprecated rbsBladeRemotePresenseKVM INTEGER, -- deprecated rbsBladeRemotePresenseRdriveR INTEGER, -- deprecated rbsBladeRemotePresenseRdriveRW INTEGER, -- deprecated rbsChassisRemotePresenseRdoc INTEGER, -- deprecated rbsRemotePresenceSupervisor INTEGER -- deprecated } roleIndex OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Index for RBS User Role entry." ::= { remoteAccessRBSroleEntry 1 } roleId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "User ID" ::= { remoteAccessRBSroleEntry 2 } rbsSupervisor OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has no restrictions." ::= { remoteAccessRBSroleEntry 3 } rbsOperator OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, etc.)." ::= { remoteAccessRBSroleEntry 4 } rbsChassisOperator OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has ability to browse status and properties of chassis components (MM, blowers (chassis cooling devices), midplane, power modules, media tray. Ability to backup MM configuration to a file. Saving MM configuration to chassis requires supervisor access." ::= { remoteAccessRBSroleEntry 5 } rbsChassisAccountManagement OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User can add/modify/delete user login profiles. Ability to backup MM configuration to a file. Changing global login settings require chassis configuration authority." ::= { remoteAccessRBSroleEntry 6 } rbsChassisLogManagement OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has ability to clear the MM event log, change log policy settings, and backup MM configuration to a file." ::= { remoteAccessRBSroleEntry 7 } rbsChassisConfiguration OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User can modify and save any chassis configuration parameter (except user profiles and event log settings). Ability to restore MM factory defaults if the user also has chassis administration permissions. Ability to change the global login settings, SOL configuration, and backup MM configuration to a file." ::= { remoteAccessRBSroleEntry 8 } rbsChassisAdministration OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has ability to do MM firmware updates, modify chassis LEDs, restore MM factory defaults if the user also has chassis configuration permissions. Ability to restart MM and backup MM configuration to a file." ::= { remoteAccessRBSroleEntry 9 } rbsBladeOperator OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has ability to browse status and properties of blades." ::= { remoteAccessRBSroleEntry 10 } rbsBladeRemotePresence OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote disk. The ability to issue the CLI console command to start an SOL session to a blade will also require this authority." ::= { remoteAccessRBSroleEntry 11 } rbsBladeConfiguration OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User can modify and save any blade configuration parameter." ::= { remoteAccessRBSroleEntry 12 } rbsBladeAdministration OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User can power on/off and restart blades, activate standby blades, do firmware updates, and modify blade LEDs." ::= { remoteAccessRBSroleEntry 13 } rbsSwitchModuleOperator OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has ability to browse status and properties of I/O Modules, and to ping I/O Modules." ::= { remoteAccessRBSroleEntry 14 } rbsSwitchModuleConfiguration OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User can modify the I/O Module IP address, configure I/O Module Advanced Management parameters, and restore factory defaults on an I/O Module. Note that a user requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet or web UI session to an I/O Module, or to restore factory defaults on an I/O Module." ::= { remoteAccessRBSroleEntry 15 } rbsSwitchModuleAdministration OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User can power on/off and restart the I/O Modules, update I/O Module firmware, enable/disable the Fast POST and External Ports of an I/O Module. Note that a user requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet or web UI session to an I/O Module, or to restore factory defaults on an I/O Module." ::= { remoteAccessRBSroleEntry 16 } rbsBladeRemotePresenseVideo OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS deprecated DESCRIPTION "User can browser Remote Control web panel and remote blade video. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool." ::= { remoteAccessRBSroleEntry 17 } rbsBladeRemotePresenseKVM OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS deprecated DESCRIPTION "User has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote disk. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool." ::= { remoteAccessRBSroleEntry 18 } rbsBladeRemotePresenseRdriveR OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS deprecated DESCRIPTION "User can mount remote blade driver, and have read access only. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool." ::= { remoteAccessRBSroleEntry 19 } rbsBladeRemotePresenseRdriveRW OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS deprecated DESCRIPTION "User can mount remote blade driver and have read/write access. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool." ::= { remoteAccessRBSroleEntry 20 } rbsChassisRemotePresenseRdoc OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS deprecated DESCRIPTION "User has ability to upload/delete own image to RDOC and also can start remote control web panel. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool." ::= { remoteAccessRBSroleEntry 21 } rbsRemotePresenceSupervisor OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS deprecated DESCRIPTION "User has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote driver read/write, upload/delete himself and other's image to RDOC. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in tool." ::= { remoteAccessRBSroleEntry 22 } remoteAccessRBSscopeTable OBJECT-TYPE SYNTAX SEQUENCE OF RemoteAccessRBSscopeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of RBS User Scope profiles." ::= { remoteAccessIds 4 } remoteAccessRBSscopeEntry OBJECT-TYPE SYNTAX RemoteAccessRBSscopeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "User Scope entries." INDEX { scopeIndex } ::= { remoteAccessRBSscopeTable 1 } RemoteAccessRBSscopeEntry ::= SEQUENCE { scopeIndex INTEGER, scopeId OCTET STRING, rbsChassis INTEGER, rbsBlade1 INTEGER, rbsBlade2 INTEGER, rbsBlade3 INTEGER, rbsBlade4 INTEGER, rbsBlade5 INTEGER, rbsBlade6 INTEGER, rbsBlade7 INTEGER, rbsBlade8 INTEGER, rbsBlade9 INTEGER, rbsBlade10 INTEGER, rbsBlade11 INTEGER, rbsBlade12 INTEGER, rbsBlade13 INTEGER, rbsBlade14 INTEGER, rbsSwitch1 INTEGER, rbsSwitch2 INTEGER, rbsSwitch3 INTEGER, rbsSwitch4 INTEGER, rbsSwitch5 INTEGER, rbsSwitch6 INTEGER, rbsSwitch7 INTEGER, rbsSwitch8 INTEGER, rbsSwitch9 INTEGER, rbsSwitch10 INTEGER } scopeIndex OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Index for RBS User Scope Entry." ::= { remoteAccessRBSscopeEntry 1 } scopeId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "User ID" ::= { remoteAccessRBSscopeEntry 2 } rbsChassis OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to the MM and chassis functions." ::= { remoteAccessRBSscopeEntry 3 } rbsBlade1 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to the blade in slot 1." ::= { remoteAccessRBSscopeEntry 4 } rbsBlade2 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to the blade in slot 2." ::= { remoteAccessRBSscopeEntry 5 } rbsBlade3 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to the blade in slot 3." ::= { remoteAccessRBSscopeEntry 6 } rbsBlade4 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to the blade in slot 4." ::= { remoteAccessRBSscopeEntry 7 } rbsBlade5 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to the blade in slot 5." ::= { remoteAccessRBSscopeEntry 8 } rbsBlade6 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to the blade in slot 6." ::= { remoteAccessRBSscopeEntry 9 } rbsBlade7 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to the blade in slot 7." ::= { remoteAccessRBSscopeEntry 10 } rbsBlade8 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to the blade in slot 8." ::= { remoteAccessRBSscopeEntry 11 } rbsBlade9 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to the blade in slot 9." ::= { remoteAccessRBSscopeEntry 12 } rbsBlade10 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to the blade in slot 10." ::= { remoteAccessRBSscopeEntry 13 } rbsBlade11 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to the blade in slot 11." ::= { remoteAccessRBSscopeEntry 14 } rbsBlade12 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to the blade in slot 12." ::= { remoteAccessRBSscopeEntry 15 } rbsBlade13 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to the blade in slot 13." ::= { remoteAccessRBSscopeEntry 16 } rbsBlade14 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to the blade in slot 14." ::= { remoteAccessRBSscopeEntry 17 } rbsSwitch1 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to I/O module 1." ::= { remoteAccessRBSscopeEntry 18 } rbsSwitch2 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to I/O module 2." ::= { remoteAccessRBSscopeEntry 19 } rbsSwitch3 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to I/O module 3." ::= { remoteAccessRBSscopeEntry 20 } rbsSwitch4 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to I/O module 4." ::= { remoteAccessRBSscopeEntry 21 } rbsSwitch5 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to I/O module 5." ::= { remoteAccessRBSscopeEntry 22 } rbsSwitch6 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to I/O module 6." ::= { remoteAccessRBSscopeEntry 23 } rbsSwitch7 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to I/O module 7." ::= { remoteAccessRBSscopeEntry 24 } rbsSwitch8 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to I/O module 8." ::= { remoteAccessRBSscopeEntry 25 } rbsSwitch9 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to I/O module 9." ::= { remoteAccessRBSscopeEntry 26 } rbsSwitch10 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "User has access to I/O module 10." ::= { remoteAccessRBSscopeEntry 27 } -- ******************************************************************************** -- Enable/Disable User Interfaces -- ******************************************************************************** userInterfaces OBJECT IDENTIFIER ::= { remoteAccessConfig 5 } cli OBJECT-TYPE SYNTAX INTEGER { disabled(0), telnet-only(1), ssh-only(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable CLI access to the MM (telnet and SSH). The value enabled(3) means both telnet and ssh are enabled." ::= { userInterfaces 1 } snmp OBJECT-TYPE SYNTAX INTEGER { disabled(0), v1-only(1), v3-only(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable SNMP v1 and v3 access to the MM." ::= { userInterfaces 2 } tcm OBJECT-TYPE SYNTAX INTEGER (0..20) ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable TCM access to the MM. A value of 0 means disabled, any value from 1 to 20 means enabled. NOTE: AMM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode." ::= { userInterfaces 3 } web OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable Web access (HTTP/HTTPS) to the MM. NOTE: Disabling web access to the MM will cause all currently active web sessions to disconnect, and you will no longer be able to access the MM management functions using a web browser." ::= { userInterfaces 4 } stcm OBJECT-TYPE SYNTAX INTEGER (0..20) ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable STCM access to the MM. A value of 0 means disabled, any value from 1 to 20 means enabled. NOTE: AMM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. If no valid server certificate is in place, Secure TCP Command Mode will not be allowed to set to enable." ::= { userInterfaces 5 } -- ---------------------------------------------------------- -- -- The Remote Access ID SSH Client Authentication Public Key Group -- ---------------------------------------------------------- -- mmSshClientAuth OBJECT IDENTIFIER ::= { remoteAccessConfig 6 } mmSshClientAuthPubKeyTable OBJECT-TYPE SYNTAX SEQUENCE OF MmSshClientAuthPubKeyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains client authentication public key information." ::= { mmSshClientAuth 1 } mmSshClientAuthPubKeyEntry OBJECT-TYPE SYNTAX MmSshClientAuthPubKeyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A information list about a particular SSH public key used for client authentication. The primary table index is the same value as the associated remoteAccessIdEntryIndex. The secondary table index allows selection of the Nth public key for that remoteAccessIdEntryIndex." INDEX { mmSshClientAuthRemoteAccessIdIndex , mmSshClientAuthPubKeyIndex } ::= { mmSshClientAuthPubKeyTable 1 } MmSshClientAuthPubKeyEntry ::= SEQUENCE { mmSshClientAuthRemoteAccessIdIndex INTEGER, mmSshClientAuthPubKeyIndex INTEGER, mmSshClientAuthPubKeyType INTEGER, mmSshClientAuthPubKeySize INTEGER, mmSshClientAuthPubKeyFingerprint OCTET STRING, mmSshClientAuthPubKeyAcceptFrom OCTET STRING, mmSshClientAuthPubKeyComment OCTET STRING, mmSshClientAuthPubKeyAction INTEGER, mmSshClientAuthPubKeyEntryStatus EntryStatus } mmSshClientAuthRemoteAccessIdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The primary table index is the same value as the associated remoteAccessIdEntryIndex used as an index into the remoteAccessIdsTable." ::= { mmSshClientAuthPubKeyEntry 1 } mmSshClientAuthPubKeyIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The secondary table index used to select one of the client authentication public keys for a particular remote access Id. The index is an integer value from 1 to N where N is the number of keys associated with a particular remote access Id. An addition always causes the value of N to increase by one, effectively adding an entry after the existing keys for that remote access Id. If an entry is deleted from the table by setting mmSshClientAuthPubKeyEntryStatus = invalid, the key associated with that entry is deleted. If the deleted key was not the last key for a remote access Id (mmSshClientAuthPubKeyIndex is not the 'last' or Nth entry), the subsequent entries are renumbered after the deletion. A deletion always causes the value of N to decrease by one. The underlying SSH server implementation searches the keys in order from 1 to N when attempting public key authentication. NOTE:A maximum of 4 public keys can be installed for one remote access Id." ::= { mmSshClientAuthPubKeyEntry 2 } mmSshClientAuthPubKeyType OBJECT-TYPE SYNTAX INTEGER { sshDss (1), sshRsa (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of the SSH public key represented by this entry." ::= { mmSshClientAuthPubKeyEntry 3 } mmSshClientAuthPubKeySize OBJECT-TYPE SYNTAX INTEGER { bits512 (1), bits768 (2), bits1024 (3), bits2048 (4), bits4096 (5) } ACCESS read-only STATUS mandatory DESCRIPTION "The size of the SSH public key represented by this entry." ::= { mmSshClientAuthPubKeyEntry 4 } mmSshClientAuthPubKeyFingerprint OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The RSA fingerprint of the SSH public key represented by this entry. This value can be used with the SSH client to verify, on the initial connection, that the Secure Shell server responding to the request is the server running on the managed entity. This is the fingerprint of the operational host key pair. If the key pair represented by this entry is not operational then sixteen null octets must be returned." ::= { mmSshClientAuthPubKeyEntry 5 } mmSshClientAuthPubKeyAcceptFrom OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This is a filter that describes the set of SSH client IP addresses and host names that can establish SSH connections to the AMM authenticated by the public key represented by this entry of the table. The filter is a comma-separated list of IP addresses and/or hostnames. A question mark may be used to match any single character. An asterisk may be used to match multiple characters. An exclamation point may preceed an IP address or hostname to deny acccess from that IP address or hostname. The format of the Accept From specification is: from=PATTERN-LIST PATTERN-LIST is the filter, which must be enclosed in double quotation marks. NOTE:This MIB object can be manipulated after the corresponding SSH public key is installed." ::= { mmSshClientAuthPubKeyEntry 6 } mmSshClientAuthPubKeyComment OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This is a descriptive string that the administrator may use to help identify the public key represented by this entry. It serves no function in the operation of the SSH server. NOTE:This MIB object can be manipulated after the corresponding SSH public key is installed." ::= { mmSshClientAuthPubKeyEntry 7 } mmSshClientAuthPubKeyAction OBJECT-TYPE SYNTAX INTEGER { import(1), export(2) } ACCESS read-write STATUS mandatory DESCRIPTION "import(1) starts the TFTP file transfer of an SSH client authentication public key from the TFTP server to the AMM. The import operation is only accepted if the associated RemoteAccessIdsEntry row is configured and the current value of mmSshClientAuthPubKeyEntryStatus is underCreation(3) or valid(1), if the current value of mmSshClientAuthPubKeyEntryStatus is valid(1), it will replace the key with a new key, If the import is successful the value of mmSshClientAuthPubKeyRowStatus changes to valid(1). export(2) starts the TFTP file transfer of an SSH client authentication public key from the AMM to the TFTP server. The export operation is only accepted if the current value of mmSshClientAuthPubKeyEntryStatus is valid(1). NOTE: Users should compare the fingerprint value mmSshClientAuthPubKeyFingerprint to the fingerprint of client authentication key files imported or exported using the TFTP file transfer protocol to guard against possible file corruption. Value returned for the GET command is meaningless for this MIB object." ::= { mmSshClientAuthPubKeyEntry 8 } mmSshClientAuthPubKeyEntryStatus OBJECT-TYPE SYNTAX EntryStatus ACCESS read-write STATUS mandatory DESCRIPTION "This object manages the creation and deletion of this entry. The steps recommended to install and to activate a new client authorization public key are: 1. Set values for mmSshClientAuthPubKeyTftpServer, mmSshClientAuthPubKeyFileName, mmSshClientAuthPubKeyFileFormat 2. Create a new entry in this table mmSshClientAuthPubKeyEntryStatus = createRequest 3. Import a new key mmSshClientAuthPubKeyAction = import This entry will be valid after mmSshClientAuthPubKeyAction is successfully imported. 4. Set mmSshClientAuthPubKeyAcceptFrom and mmSshClientAuthPubKeyComment as required. valid(1) - Indicates that the public key pair represented by this entry is available for use by the Secure Shell Server for client authentication. createRequest(2) - A new entry will be created in this table for the specified host key pair and the new entry will transition to the underCreation(3) state. The operation is only accepted if the associated RemoteAccessIdsEntry row defining a local user account is configured. underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to underCreation(3). invalid(4) - Deletes this entry and any client authentication public key that may be associated with it." ::= { mmSshClientAuthPubKeyEntry 9 } mmSshClientAuthPubKeyUnused OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of available storage locations that may be used to install additional Client Authentication Public Keys. This number decreases by one when a new key is added to the configuration." ::= { mmSshClientAuth 2 } mmSshClientAuthPubKeyTftpServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or host name of the TFTP server where an SSH client authentication public key is to be installed from or exported to. The address must be entered in a dotted decimal IP string (e.g. 9.37.44.2)." ::= { mmSshClientAuth 3 } mmSshClientAuthPubKeyFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "File name on the TFTP server of an SSH client authentication public key." ::= { mmSshClientAuth 4 } mmSshClientAuthPubKeyFileFormat OBJECT-TYPE SYNTAX INTEGER { openSSH (1), rfc4716 (2) } ACCESS read-write STATUS mandatory DESCRIPTION "File format of SSH client authentication public key files imported from or exported to the TFTP file server." ::= { mmSshClientAuth 5 } -- ******************************************************************************** -- Group Profiles for LDAP Users -- ******************************************************************************** groupProfiles OBJECT IDENTIFIER ::= { remoteAccessConfig 7 } groupIdsTable OBJECT-TYPE SYNTAX SEQUENCE OF GroupIdsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Group profiles. This table lets you to configure all group profiles. You can define up to 16 unique profiles." ::= { groupProfiles 1 } groupIdsEntry OBJECT-TYPE SYNTAX GroupIdsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Group ID entries." INDEX { groupIndex } ::= { groupIdsTable 1 } GroupIdsEntry ::= SEQUENCE { groupIndex INTEGER, groupId OCTET STRING, groupRole OCTET STRING, groupEntryStatus EntryStatus } groupIndex OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Index for Group IDs entry." ::= { groupIdsEntry 1 } groupId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) ACCESS read-write STATUS mandatory DESCRIPTION "Group ID. It is a null terminated string that contains the group-id. It must not be a duplicate of any previously configured ones." ::= { groupIdsEntry 2 } groupRole OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Group Role. It indicates if the group has supervisor, operator, or custom access." ::= { groupIdsEntry 3 } groupEntryStatus OBJECT-TYPE SYNTAX EntryStatus ACCESS read-write STATUS mandatory DESCRIPTION "This object manages the creation and deletion of this entry. The steps recommended to add a new group are: 1. Create a new entry in this table groupEntryStatus = createRequest 2. Set groupId as required. Then the entry will be valid. valid(1) - Indicates that the group represented by this entry is available for use. createRequest(2) - A new entry will be created in this table for the specified group and the new entry will transition to the underCreation(3). underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to underCreation(3). invalid(4) - Deletes this entry." ::= { groupIdsEntry 9 } groupRBSroleTable OBJECT-TYPE SYNTAX SEQUENCE OF GroupRBSroleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Group Role profiles." ::= { groupProfiles 2 } groupRBSroleEntry OBJECT-TYPE SYNTAX GroupRBSroleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Group Role entries." INDEX { groupRBSroleIndex } ::= { groupRBSroleTable 1 } GroupRBSroleEntry ::= SEQUENCE { groupRBSroleIndex INTEGER, groupRBSroleId OCTET STRING, groupRBSSupervisor INTEGER, groupRBSOperator INTEGER, groupRBSChassisOperator INTEGER, groupRBSChassisAccountManagement INTEGER, groupRBSChassisLogManagement INTEGER, groupRBSChassisConfiguration INTEGER, groupRBSChassisAdministration INTEGER, groupRBSBladeOperator INTEGER, groupRBSBladeRemotePresence INTEGER, groupRBSBladeConfiguration INTEGER, groupRBSBladeAdministration INTEGER, groupRBSSwitchModuleOperator INTEGER, groupRBSSwitchModuleConfiguration INTEGER, groupRBSSwitchModuleAdministration INTEGER } groupRBSroleIndex OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Index for Group Role entry." ::= { groupRBSroleEntry 1 } groupRBSroleId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "Group ID" ::= { groupRBSroleEntry 2 } groupRBSSupervisor OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has no restrictions." ::= { groupRBSroleEntry 3 } groupRBSOperator OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, etc.)." ::= { groupRBSroleEntry 4 } groupRBSChassisOperator OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has ability to browse status and properties of chassis components (MM, blowers (chassis cooling devices), midplane, power modules, media tray. Ability to backup MM configuration to a file. Saving MM configuration to chassis requires supervisor access." ::= { groupRBSroleEntry 5 } groupRBSChassisAccountManagement OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group can add/modify/delete user login profiles. Ability to backup MM configuration to a file. Changing global login settings require chassis configuration authority." ::= { groupRBSroleEntry 6 } groupRBSChassisLogManagement OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has ability to clear the MM event log, change log policy settings, and backup MM configuration to a file." ::= { groupRBSroleEntry 7 } groupRBSChassisConfiguration OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group can modify and save any chassis configuration parameter (except user profiles and event log settings). Ability to restore MM factory defaults if the group also has chassis administration permissions. Ability to change the global login settings, SOL configuration, and backup MM configuration to a file." ::= { groupRBSroleEntry 8 } groupRBSChassisAdministration OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has ability to do MM firmware updates, modify chassis LEDs, restore MM factory defaults if the group also has chassis configuration permissions. Ability to restart MM and backup MM configuration to a file." ::= { groupRBSroleEntry 9 } groupRBSBladeOperator OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has ability to browse status and properties of blades." ::= { groupRBSroleEntry 10 } groupRBSBladeRemotePresence OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote disk. The ability to issue the CLI console command to start an SOL session to a blade will also require this authority." ::= { groupRBSroleEntry 11 } groupRBSBladeConfiguration OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group can modify and save any blade configuration parameter." ::= { groupRBSroleEntry 12 } groupRBSBladeAdministration OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group can power on/off and restart blades, activate standby blades, do firmware updates, and modify blade LEDs." ::= { groupRBSroleEntry 13 } groupRBSSwitchModuleOperator OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has ability to browse status and properties of I/O Modules, and to ping I/O Modules." ::= { groupRBSroleEntry 14 } groupRBSSwitchModuleConfiguration OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group can modify the I/O Module IP address, configure I/O Module Advanced Management parameters, and restore factory defaults on an I/O Module. Note that a group requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet or web UI session to an I/O Module, or to restore factory defaults on an I/O Module." ::= { groupRBSroleEntry 15 } groupRBSSwitchModuleAdministration OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group can power on/off and restart the I/O Modules, update I/O Module firmware, enable/disable the Fast POST and External Ports of an I/O Module. Note that a group requires both I/O Module configuration and I/O Module administration roles in order to be able to launch a telnet or web UI session to an I/O Module, or to restore factory defaults on an I/O Module." ::= { groupRBSroleEntry 16 } groupRBSscopeTable OBJECT-TYPE SYNTAX SEQUENCE OF GroupRBSscopeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Group Scope profiles." ::= { groupProfiles 3 } groupRBSscopeEntry OBJECT-TYPE SYNTAX GroupRBSscopeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Group Scope entries." INDEX { groupRBSscopeIndex } ::= { groupRBSscopeTable 1 } GroupRBSscopeEntry ::= SEQUENCE { groupRBSscopeIndex INTEGER, groupRBSscopeId OCTET STRING, groupRBSChassis INTEGER, groupRBSBlade1 INTEGER, groupRBSBlade2 INTEGER, groupRBSBlade3 INTEGER, groupRBSBlade4 INTEGER, groupRBSBlade5 INTEGER, groupRBSBlade6 INTEGER, groupRBSBlade7 INTEGER, groupRBSBlade8 INTEGER, groupRBSBlade9 INTEGER, groupRBSBlade10 INTEGER, groupRBSBlade11 INTEGER, groupRBSBlade12 INTEGER, groupRBSBlade13 INTEGER, groupRBSBlade14 INTEGER, groupRBSSwitch1 INTEGER, groupRBSSwitch2 INTEGER, groupRBSSwitch3 INTEGER, groupRBSSwitch4 INTEGER, groupRBSSwitch5 INTEGER, groupRBSSwitch6 INTEGER, groupRBSSwitch7 INTEGER, groupRBSSwitch8 INTEGER, groupRBSSwitch9 INTEGER, groupRBSSwitch10 INTEGER } groupRBSscopeIndex OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Index for Group Scope Entry." ::= { groupRBSscopeEntry 1 } groupRBSscopeId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "Group ID" ::= { groupRBSscopeEntry 2 } groupRBSChassis OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to the MM and chassis functions." ::= { groupRBSscopeEntry 3 } groupRBSBlade1 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to the blade in slot 1." ::= { groupRBSscopeEntry 4 } groupRBSBlade2 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to the blade in slot 2." ::= { groupRBSscopeEntry 5 } groupRBSBlade3 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to the blade in slot 3." ::= { groupRBSscopeEntry 6 } groupRBSBlade4 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to the blade in slot 4." ::= { groupRBSscopeEntry 7 } groupRBSBlade5 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to the blade in slot 5." ::= { groupRBSscopeEntry 8 } groupRBSBlade6 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to the blade in slot 6." ::= { groupRBSscopeEntry 9 } groupRBSBlade7 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to the blade in slot 7." ::= { groupRBSscopeEntry 10 } groupRBSBlade8 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to the blade in slot 8." ::= { groupRBSscopeEntry 11 } groupRBSBlade9 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to the blade in slot 9." ::= { groupRBSscopeEntry 12 } groupRBSBlade10 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to the blade in slot 10." ::= { groupRBSscopeEntry 13 } groupRBSBlade11 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to the blade in slot 11." ::= { groupRBSscopeEntry 14 } groupRBSBlade12 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to the blade in slot 12." ::= { groupRBSscopeEntry 15 } groupRBSBlade13 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to the blade in slot 13." ::= { groupRBSscopeEntry 16 } groupRBSBlade14 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to the blade in slot 14." ::= { groupRBSscopeEntry 17 } groupRBSSwitch1 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to I/O module 1." ::= { groupRBSscopeEntry 18 } groupRBSSwitch2 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to I/O module 2." ::= { groupRBSscopeEntry 19 } groupRBSSwitch3 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to I/O module 3." ::= { groupRBSscopeEntry 20 } groupRBSSwitch4 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to I/O module 4." ::= { groupRBSscopeEntry 21 } groupRBSSwitch5 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to I/O module 5." ::= { groupRBSscopeEntry 22 } groupRBSSwitch6 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to I/O module 6." ::= { groupRBSscopeEntry 23 } groupRBSSwitch7 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to I/O module 7." ::= { groupRBSscopeEntry 24 } groupRBSSwitch8 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to I/O module 8." ::= { groupRBSscopeEntry 25 } groupRBSSwitch9 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to I/O module 9." ::= { groupRBSscopeEntry 26 } groupRBSSwitch10 OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Group has access to I/O module 10." ::= { groupRBSscopeEntry 27 } -- ******************************************************************************** -- Remote Alert types -- ******************************************************************************** remoteAlerts OBJECT IDENTIFIER ::= { configureSP 2 } -- ******************************************************************************** -- Remote Alert Critical Error types -- ******************************************************************************** remoteAlertsCrit OBJECT IDENTIFIER ::= { remoteAlerts 1 } critTemp OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Generate an alert if any of the monitored temperature sensors in the system exceed their critical threshold. NOTE: If a critical Temperature condition is detected, the server will automatically be shut down and powered off whether this object is enabled or not. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts." ::= { remoteAlertsCrit 1 } critVolt OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Generate a alert if any of the monitored power supply sensors in the system fall outside their specified critical operational range. NOTE: If a critical voltage condition is detected, the server will automatically be shut down and powered off whether this object is enabled or not. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts." ::= { remoteAlertsCrit 2 } critMultiBlower OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Generate an alert if multiple blowers used for cooling the system fail. NOTE: Blowers are also referred to as Chassis Cooling Devices. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts." ::= { remoteAlertsCrit 4 } critPower OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert if any of the system power supplies fail. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsCrit 5 } critHardDrive OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Generate an alert if any of hard disk drives fail. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts." ::= { remoteAlertsCrit 6 } critVRM OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Generate an alert if any of VRM (voltage regulator modules) fail. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts." ::= { remoteAlertsCrit 7 } critMultipleSwitchModule OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Generate an alert if all switch modules fail or are removed. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts." ::= { remoteAlertsCrit 8 } critInvalidConfig OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Generate an alert if the hardware configuration is incompatible. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts." ::= { remoteAlertsCrit 9 } critBlade OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert for any critical error condition on a blade. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsCrit 10 } critIO OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert for any critical error condition on I/O module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsCrit 11 } critStorage OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert for any critical error condition on a Storage module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration. NOTE: This MIB object is for BCS only." ::= { remoteAlertsCrit 12 } critChassis OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert for any critical error condition on chassis. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsCrit 13 } critFan OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert for any critical error condition on cooling devices. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsCrit 14 } -- ******************************************************************************** -- Remote Alert Warning(non-critical) Error types -- ******************************************************************************** remoteAlertsNonCrit OBJECT IDENTIFIER ::= { remoteAlerts 2 } warnSingleBlower OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Generate an alert if one blower used for cooling the system fails. NOTE: Blowers are also referred to as Chassis Cooling Devices. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts." ::= { remoteAlertsNonCrit 2 } warnTemp OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Generate an alert if any of the monitored temperature sensors in the system exceed their warning threshold. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts." ::= { remoteAlertsNonCrit 3 } warnVoltage OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Generate an alert if any of the monitored power supply sensors in the system fall outside their specified warning operational range. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts." ::= { remoteAlertsNonCrit 4 } warnRedundantModule OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Generate an alert if any of the switch modules or management modules is failing or removed. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts." ::= { remoteAlertsNonCrit 6 } warnMediaTrayKVMSwitch OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Generate an alert if the system detects a Media Tray or KVM switching failure. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts." ::= { remoteAlertsNonCrit 7 } warnLogFull OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert if the system log reaches 100% full. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsNonCrit 10 } warnBlade OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert for any warning condition on a blade. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsNonCrit 15 } warnIO OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert for any warning condition on I/O module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsNonCrit 16 } warnStorage OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert for any warning condition on a Storage module. NOTE: This MIB object is for BCS only. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsNonCrit 17 } warnPower OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert for any warning condition on power module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsNonCrit 18 } warnChassis OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert for any warning condition on chassis. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsNonCrit 19 } warnFan OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert for any warning condition on cooling devices. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsNonCrit 20 } -- ******************************************************************************** -- Remote Alert System Error types -- ******************************************************************************** remoteAlertsSystem OBJECT IDENTIFIER ::= { remoteAlerts 3 } systemPowerOff OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Generate an alert if the system is powered off. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts." ::= { remoteAlertsSystem 4 } systemPowerOn OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Generate a alert if the system is powered on. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts." ::= { remoteAlertsSystem 5 } systemPFA OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Generate a alert if the system hardware detects a Predictive Failure Analysis(PFA) on PFA enabled hardware. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts." ::= { remoteAlertsSystem 8 } systemInventory OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert if the a processor blade or media tray is added or removed. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsSystem 10 } systemLog75PctFull OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert if the system log reaches 75% full. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsSystem 11 } networkChangeNotification OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert if the SP has restarted and the internal network has initialized successfully, or if an IP address change via a source other than the management module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsSystem 12 } systemBladeThrottling OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Generate an alert if any of the server blades are throttling. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts." ::= { remoteAlertsSystem 13 } systemPowerManagement OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS deprecated DESCRIPTION "Generate an alert if the system detects a power oversubscription condition or power supply mismatch in a power domain. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts." ::= { remoteAlertsSystem 14 } systemRemoteLogin OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert if the system detects a new user logged in from a remote site. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsSystem 15 } systemBlade OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert for any informational condition on a blade. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsSystem 16 } systemIO OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert for any informational condition on I/O module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsSystem 17 } systemStorage OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert for any informational condition on a Storage module. NOTE: This MIB object is for BCS only. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsSystem 18 } systemPower OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert for any informational condition on power module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsSystem 19 } systemChassis OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert for any informational condition on chassis. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsSystem 20} systemFan OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert for any informational condition on cooling device. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsSystem 21} systemPWRDO OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate an alert for any informational condition on power on and power off. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert category configuration." ::= { remoteAlertsSystem 22} -- Flag to select whether the alert categories function in the legacy mode or -- the enhanced mode. alertMode OBJECT-TYPE SYNTAX INTEGER { legacy(0), enhanced(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects which alert categories will be displayed on the web interface, which alert category objects are accessible through SNMP, and which SNMP trap type an alert is associated with. The enhanced option provides a component based category category scheme and is the only one that is now supported. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are now also changed to be read-only and any future modifications to the alert category settings must be done only with the enahanced(1) mode alerts. Therefore, this setting should have a value of enhanced(1)." ::= { remoteAlerts 4 } -- ******************************************************************************** -- Users -- ******************************************************************************** -- users OBJECT IDENTIFIER ::= { monitors 17 } -- ******************************************************************************** -- MM Users -- ******************************************************************************** -- mmUsers OBJECT IDENTIFIER ::= { users 1 } currentlyLoggedInTable OBJECT-TYPE SYNTAX SEQUENCE OF CurrentlyLoggedInEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of MM users currently logged in. NOTE: This MIB object is for AMM only." ::= { mmUsers 1 } currentlyLoggedInEntry OBJECT-TYPE SYNTAX CurrentlyLoggedInEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "MM users currently logged in entries. NOTE: This MIB object is for AMM only." INDEX { currentlyLoggedInEntryIndex } ::= { currentlyLoggedInTable 1 } CurrentlyLoggedInEntry ::= SEQUENCE { currentlyLoggedInEntryIndex INTEGER, currentlyLoggedInEntryUserId OCTET STRING, currentlyLoggedInEntryAccMethod OCTET STRING } currentlyLoggedInEntryIndex OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Index for MM users currently logged in." ::= { currentlyLoggedInEntry 1 } currentlyLoggedInEntryUserId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Name for MM users currently logged in. NOTE: 'Default SNMPv1 user' indicates an internal user used by SNMPv1 agent." ::= { currentlyLoggedInEntry 2 } currentlyLoggedInEntryAccMethod OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Access method for MM users currently logged in." ::= { currentlyLoggedInEntry 3 } -- ******************************************************************************** -- Front Bezel -- ******************************************************************************** frontbezel OBJECT IDENTIFIER ::= { monitors 12 } frontbezelExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the front bezel is installed or not. NOTE: This MIB object is for BladeCenter HT only." ::= { frontbezel 1} -- ******************************************************************************** -- Environmental Monitor Thresholds -- ******************************************************************************** monitorThresholds OBJECT IDENTIFIER ::= { monitors 20 } -- ******************************************************************************** -- Voltage Thresholds -- ******************************************************************************** voltageThresholds OBJECT IDENTIFIER ::= { monitorThresholds 2 } voltageThresholdsTable OBJECT-TYPE SYNTAX SEQUENCE OF VoltageThresholdsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of voltage threshold entries. NOTE: This MIB object is for BladeCenter only." ::= { voltageThresholds 1 } voltageThresholdsEntry OBJECT-TYPE SYNTAX VoltageThresholdsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Voltage threshold entries. NOTE: This MIB object is for BladeCenter only." INDEX { voltageThresholdEntryIndex } ::= { voltageThresholdsTable 1 } VoltageThresholdsEntry ::= SEQUENCE { voltageThresholdEntryIndex INTEGER, voltageThresholdEntryName OCTET STRING, voltageThresholdEntryCurrentValue OCTET STRING, voltageThresholdEntryWarningHighValue OCTET STRING, voltageThresholdEntryWarningResetHighValue OCTET STRING, voltageThresholdEntryWarningLowValue OCTET STRING, voltageThresholdEntryWarningResetLowValue OCTET STRING } voltageThresholdEntryIndex OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Index for voltage threshold entry." ::= { voltageThresholdsEntry 1 } voltageThresholdEntryName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "Voltage threshold entry null terminated string that contains the power supply's name, for example '+5V'." ::= { voltageThresholdsEntry 2 } voltageThresholdEntryCurrentValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system." ::= { voltageThresholdsEntry 3 } voltageThresholdEntryWarningHighValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage threshold reading expressed in Volts(V). If the voltage rises above this value, a warning alert/event, if enabled, will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system." ::= { voltageThresholdsEntry 6 } voltageThresholdEntryWarningResetHighValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage threshold reading expressed in Volts(V). If the voltage rises above this value and if a warning alert/event had previously been created, then the alert/event will be reset. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system." ::= { voltageThresholdsEntry 7 } voltageThresholdEntryWarningLowValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage threshold reading expressed in Volts(V). If the voltage drops below this value, a warning alert/event, if enabled, will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system." ::= { voltageThresholdsEntry 10 } voltageThresholdEntryWarningResetLowValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage threshold reading expressed in Volts(V). If the voltage drops below this value and if a warning alert/event had previously been created, then the alert/event will be reset. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system." ::= { voltageThresholdsEntry 11 } -- ******************************************************************************** -- Vital Product Data(VPD) information -- ******************************************************************************** vpdInformation OBJECT IDENTIFIER ::= { monitors 21 } -- ******************************************************************************** -- System Firmware Level VPD -- ******************************************************************************** -- ******************************************************************************** -- Machine Level VPD -- ******************************************************************************** chassisVpd OBJECT IDENTIFIER ::= { vpdInformation 1 } bladeCenterVpd OBJECT IDENTIFIER ::= { chassisVpd 1 } bladeCenterVpdMachineType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Machine type VPD information (from System BIOS). This field must be four alpha numeric characters." ::= { bladeCenterVpd 1 } bladeCenterVpdMachineModel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Machine model VPD information (from System BIOS). This field must be three alpha numeric characters." ::= { bladeCenterVpd 2 } bladeCenterSerialNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Machine serial number VPD information (from System BIOS). This field must be seven alpha numeric characters." ::= { bladeCenterVpd 3 } bladeCenterUUID OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Machine UUID (Universal Unique ID information) (from System BIOS). This field must be 32 alpha numeric characters." ::= { bladeCenterVpd 4 } bladeCenterManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Machine chassis manufacturing ID." ::= { bladeCenterVpd 5 } bladeCenterHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Machine chassis hardware revision. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { bladeCenterVpd 6 } bladeCenterFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Machine chassis FRU number." ::= { bladeCenterVpd 7 } bladeCenterManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Machine chassis manufacture date." ::= { bladeCenterVpd 8 } bladeCenterPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Machine chassis part number." ::= { bladeCenterVpd 9 } bladeCenterFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Machine chassis FRU serial number." ::= { bladeCenterVpd 10 } bladeCenterManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Machine chassis manufacturer ID Number." ::= { bladeCenterVpd 11 } bladeCenterProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Machine chassis product ID." ::= { bladeCenterVpd 12 } bladeCenterSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Machine chassis subsystem manufacturer." ::= { bladeCenterVpd 13 } bladeCenterClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Machine chassis Common Language Equipment Identification (CLEI)." ::= { bladeCenterVpd 14 } bladeCenterDirectSerialAttach OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Presence of the Direct Serial Attach Module. NOTE: This MIB object is for BCS only." ::= { bladeCenterVpd 15 } bladeCenterHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Machine chassis hardware revision in string format. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used." ::= { bladeCenterVpd 16 } -- ******************************************************************************** -- Management Module Hardware VPD -- ******************************************************************************** mmHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 2 } mmHardwareVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF MmHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of the management module hardware components. For consistent results, view as a table and not as individual entries." ::= { mmHardwareVpd 1 } mmHardwareVpdEntry OBJECT-TYPE SYNTAX MmHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Management module hardware VPD entry. For consistent results, view as a table and not as individual entries." INDEX { mmHardwareVpdIndex } ::= { mmHardwareVpdTable 1 } MmHardwareVpdEntry ::= SEQUENCE { mmHardwareVpdIndex INTEGER, mmHardwareVpdBayNumber OCTET STRING, mmHardwareVpdManufacturingId OCTET STRING, mmHardwareVpdFruNumber OCTET STRING, mmHardwareVpdHardwareRevision INTEGER, mmHardwareVpdUuid OCTET STRING, mmHardwareVpdManufDate OCTET STRING, mmHardwareVpdPartNumber OCTET STRING, mmHardwareVpdFruSerial OCTET STRING, mmHardwareVpdManufacturingIDNumber OCTET STRING, mmHardwareVpdProductId OCTET STRING, mmHardwareVpdSubManufacturerId OCTET STRING, mmHardwareVpdClei OCTET STRING, mmHardwareVpdHardwareRevisionString OCTET STRING } mmHardwareVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Management module hardware VPD index. For consistent results, view as a table and not as individual entries." ::= { mmHardwareVpdEntry 1 } mmHardwareVpdBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module hardware VPD Bay number. For consistent results, view as a table and not as individual entries." ::= { mmHardwareVpdEntry 2 } mmHardwareVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries." ::= { mmHardwareVpdEntry 3 } mmHardwareVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module hardware VPD FRU number. For consistent results, view as a table and not as individual entries." ::= { mmHardwareVpdEntry 4 } mmHardwareVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Management module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { mmHardwareVpdEntry 5 } mmHardwareVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module hardware VPD UUID. For consistent results, view as a table and not as individual entries." ::= { mmHardwareVpdEntry 6 } mmHardwareVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module hardware VPD manufacture date. For consistent results, view as a table and not as individual entries." ::= { mmHardwareVpdEntry 7 } mmHardwareVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module hardware VPD Part number. For consistent results, view as a table and not as individual entries." ::= { mmHardwareVpdEntry 8 } mmHardwareVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries." ::= { mmHardwareVpdEntry 9 } mmHardwareVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module hardware VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries." ::= { mmHardwareVpdEntry 10 } mmHardwareVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module hardware VPD product ID. For consistent results, view as a table and not as individual entries." ::= { mmHardwareVpdEntry 11 } mmHardwareVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module hardware VPD subsystem manufacturer. For consistent results, view as a table and not as individual entries." ::= { mmHardwareVpdEntry 12 } mmHardwareVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module hardware VPD Common Language Equipment Identification (CLEI). For consistent results, view as a table and not as individual entries." ::= { mmHardwareVpdEntry 13 } mmHardwareVpdHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used." ::= { mmHardwareVpdEntry 14 } -- ******************************************************************************** -- Management Module Interposer Hardware VPD -- ******************************************************************************** mmInpHardwareVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF MmInpHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of the management module interposer hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { mmHardwareVpd 2 } mmInpHardwareVpdEntry OBJECT-TYPE SYNTAX MmInpHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Management module Interposer hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." INDEX { mmInpHardwareVpdIndex } ::= { mmInpHardwareVpdTable 1 } MmInpHardwareVpdEntry ::= SEQUENCE { mmInpHardwareVpdIndex INTEGER, mmInpHardwareVpdBayNumber OCTET STRING, mmInpHardwareVpdManufacturingId OCTET STRING, mmInpHardwareVpdFruNumber OCTET STRING, mmInpHardwareVpdHardwareRevision INTEGER, mmInpHardwareVpdUuid OCTET STRING, mmInpHardwareVpdManufDate OCTET STRING, mmInpHardwareVpdPartNumber OCTET STRING, mmInpHardwareVpdFruSerial OCTET STRING, mmInpHardwareVpdManufacturingIDNumber OCTET STRING, mmInpHardwareVpdProductId OCTET STRING, mmInpHardwareVpdSubManufacturerId OCTET STRING, mmInpHardwareVpdClei OCTET STRING, mmInpHardwareVpdHardwareRevisionString OCTET STRING } mmInpHardwareVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Management module Interposer hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { mmInpHardwareVpdEntry 1 } mmInpHardwareVpdBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module Interposer hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { mmInpHardwareVpdEntry 2 } mmInpHardwareVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module Interposer hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { mmInpHardwareVpdEntry 3 } mmInpHardwareVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module Interposer hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { mmInpHardwareVpdEntry 4 } mmInpHardwareVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Management module Interposer hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { mmInpHardwareVpdEntry 5 } mmInpHardwareVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module Interposer hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { mmInpHardwareVpdEntry 6 } mmInpHardwareVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module Interposer hardware VPD manufacture date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { mmInpHardwareVpdEntry 7 } mmInpHardwareVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module Interposer hardware VPD Part number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { mmInpHardwareVpdEntry 8 } mmInpHardwareVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module Interposer hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { mmInpHardwareVpdEntry 9 } mmInpHardwareVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module Interposer hardware VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries." ::= { mmInpHardwareVpdEntry 10 } mmInpHardwareVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module Interposer hardware VPD product ID. For consistent results, view as a table and not as individual entries." ::= { mmInpHardwareVpdEntry 11 } mmInpHardwareVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module Interposer hardware VPD subsystem manufacturer. For consistent results, view as a table and not as individual entries." ::= { mmInpHardwareVpdEntry 12 } mmInpHardwareVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module Interposer hardware VPD Common Language Equipment Identification (CLEI). For consistent results, view as a table and not as individual entries." ::= { mmInpHardwareVpdEntry 13 } mmInpHardwareVpdHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module Interposer hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then this version of this MIB object should be used." ::= { mmInpHardwareVpdEntry 14 } -- ******************************************************************************** -- System Firmware Level VPD -- ******************************************************************************** mmFirmwareVpd OBJECT IDENTIFIER ::= { vpdInformation 3 } -- ******************************************************************************** -- MM Firmware VPD -- ******************************************************************************** mmMainApplVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF MmMainApplVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of MM Firmware VPD." ::= { mmFirmwareVpd 1 } mmMainApplVpdEntry OBJECT-TYPE SYNTAX MmMainApplVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "MM Firmware VPD entry." INDEX { mmMainApplVpdIndex } ::= { mmMainApplVpdTable 1 } MmMainApplVpdEntry ::= SEQUENCE { mmMainApplVpdIndex INTEGER, mmMainApplVpdName OCTET STRING, mmMainApplVpdBuildId OCTET STRING, mmMainApplVpdRevisonNumber OCTET STRING, mmMainApplVpdFilename OCTET STRING, mmMainApplVpdBuildDate OCTET STRING } mmMainApplVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Firmware VPD index." ::= { mmMainApplVpdEntry 1 } mmMainApplVpdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Firmware VPD name description. 'AMM firmware' indicates the running firmware of the MM. 'AMM firmware (pending restart)' indicates the flashed firmware of the MM which will become active after the next restart." ::= { mmMainApplVpdEntry 2 } mmMainApplVpdBuildId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Firmware VPD build identification." ::= { mmMainApplVpdEntry 3 } mmMainApplVpdRevisonNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Firmware VPD revision number." ::= { mmMainApplVpdEntry 4 } mmMainApplVpdFilename OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Firmware VPD file name." ::= { mmMainApplVpdEntry 5 } mmMainApplVpdBuildDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Firmware VPD build date." ::= { mmMainApplVpdEntry 6 } -- ******************************************************************************** -- MM Firmware VPD -- ******************************************************************************** mmBootROMVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF MmBootROMVpdEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Table of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported." ::= { mmFirmwareVpd 2 } mmBootROMVpdEntry OBJECT-TYPE SYNTAX MmBootROMVpdEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "MM Firmware VPD entry. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported." INDEX { mmBootROMVpdIndex } ::= { mmBootROMVpdTable 1 } MmBootROMVpdEntry ::= SEQUENCE { mmBootROMVpdIndex INTEGER, --deprecated mmBootROMVpdName OCTET STRING, --deprecated mmBootROMVpdBuildId OCTET STRING, --deprecated mmBootROMVpdRevisonNumber OCTET STRING, --deprecated mmBootROMVpdFilename OCTET STRING, --deprecated mmBootROMVpdBuildDate OCTET STRING --deprecated } mmBootROMVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD index. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported." ::= { mmBootROMVpdEntry 1 } mmBootROMVpdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD name description. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported." ::= { mmBootROMVpdEntry 2 } mmBootROMVpdBuildId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD build identification. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported." ::= { mmBootROMVpdEntry 3 } mmBootROMVpdRevisonNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD revision number. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported." ::= { mmBootROMVpdEntry 4 } mmBootROMVpdFilename OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD file name. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported." ::= { mmBootROMVpdEntry 5 } mmBootROMVpdBuildDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD build date. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported." ::= { mmBootROMVpdEntry 6 } -- ******************************************************************************** -- MM Firmware VPD -- ******************************************************************************** mmRemoteControlVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF MmRemoteControlVpdEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Table of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported." ::= { mmFirmwareVpd 3 } mmRemoteControlVpdEntry OBJECT-TYPE SYNTAX MmRemoteControlVpdEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "MM Firmware VPD entry. NOTE: This table is deprecated and no longer supported." INDEX { mmRemoteControlVpdIndex } ::= { mmRemoteControlVpdTable 1 } MmRemoteControlVpdEntry ::= SEQUENCE { mmRemoteControlVpdIndex INTEGER, --deprecated mmRemoteControlVpdName OCTET STRING, --deprecated mmRemoteControlVpdBuildId OCTET STRING, --deprecated mmRemoteControlVpdRevisonNumber OCTET STRING, --deprecated mmRemoteControlVpdFilename OCTET STRING, --deprecated mmRemoteControlVpdBuildDate OCTET STRING --deprecated } mmRemoteControlVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD index. NOTE: This Mib object is deprecated and no longer supported." ::= { mmRemoteControlVpdEntry 1 } mmRemoteControlVpdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD name description. NOTE: This Mib object is deprecated and no longer supported." ::= { mmRemoteControlVpdEntry 2 } mmRemoteControlVpdBuildId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD build identification. NOTE: This Mib object is deprecated and no longer supported." ::= { mmRemoteControlVpdEntry 3 } mmRemoteControlVpdRevisonNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD revision number. NOTE: This Mib object is deprecated and no longer supported." ::= { mmRemoteControlVpdEntry 4 } mmRemoteControlVpdFilename OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD file name. NOTE: This Mib object is deprecated and no longer supported." ::= { mmRemoteControlVpdEntry 5 } mmRemoteControlVpdBuildDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD build date. NOTE: This Mib object is deprecated and no longer supported." ::= { mmRemoteControlVpdEntry 6 } -- ******************************************************************************** -- MM Firmware VPD -- ******************************************************************************** mmPS2toUSBConvVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF MmPS2toUSBConvVpdEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Table of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported." ::= { mmFirmwareVpd 4 } mmPS2toUSBConvVpdEntry OBJECT-TYPE SYNTAX MmPS2toUSBConvVpdEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "MM Firmware VPD entry. NOTE: This table is deprecated and no longer supported." INDEX { mmPS2toUSBConvVpdIndex } ::= { mmPS2toUSBConvVpdTable 1 } MmPS2toUSBConvVpdEntry ::= SEQUENCE { mmPS2toUSBConvVpdIndex INTEGER, --deprecated mmPS2toUSBConvVpdName OCTET STRING, --deprecated mmPS2toUSBConvVpdBuildId OCTET STRING, --deprecated mmPS2toUSBConvVpdRevisonNumber OCTET STRING, --deprecated mmPS2toUSBConvVpdFilename OCTET STRING, --deprecated mmPS2toUSBConvVpdBuildDate OCTET STRING --deprecated } mmPS2toUSBConvVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD index. NOTE: This Mib object is deprecated and no longer supported." ::= { mmPS2toUSBConvVpdEntry 1 } mmPS2toUSBConvVpdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD name description. NOTE: This Mib object is deprecated and no longer supported." ::= { mmPS2toUSBConvVpdEntry 2 } mmPS2toUSBConvVpdBuildId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD build identification. NOTE: This Mib object is deprecated and no longer supported." ::= { mmPS2toUSBConvVpdEntry 3 } mmPS2toUSBConvVpdRevisonNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD revision number. NOTE: This Mib object is deprecated and no longer supported." ::= { mmPS2toUSBConvVpdEntry 4 } mmPS2toUSBConvVpdFilename OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD file name. NOTE: This Mib object is deprecated and no longer supported." ::= { mmPS2toUSBConvVpdEntry 5 } mmPS2toUSBConvVpdBuildDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD build date. NOTE: This Mib object is deprecated and no longer supported." ::= { mmPS2toUSBConvVpdEntry 6 } -- ******************************************************************************** -- MM Firmware VPD -- ******************************************************************************** mmToUSBIntfVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF MmToUSBIntfVpdEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Table of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported." ::= { mmFirmwareVpd 5 } mmToUSBIntfVpdEntry OBJECT-TYPE SYNTAX MmToUSBIntfVpdEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "MM Firmware VPD entry. NOTE: This table is deprecated and no longer supported." INDEX { mmToUSBIntfVpdIndex } ::= { mmToUSBIntfVpdTable 1 } MmToUSBIntfVpdEntry ::= SEQUENCE { mmToUSBIntfVpdIndex INTEGER, --deprecated mmToUSBIntfVpdName OCTET STRING, --deprecated mmToUSBIntfVpdBuildId OCTET STRING, --deprecated mmToUSBIntfVpdRevisonNumber OCTET STRING, --deprecated mmToUSBIntfVpdFilename OCTET STRING, --deprecated mmToUSBIntfVpdBuildDate OCTET STRING --deprecated } mmToUSBIntfVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD index. NOTE: This Mib object is deprecated and no longer supported." ::= { mmToUSBIntfVpdEntry 1 } mmToUSBIntfVpdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD name description. NOTE: This Mib object is deprecated and no longer supported." ::= { mmToUSBIntfVpdEntry 2 } mmToUSBIntfVpdBuildId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD build identification. NOTE: This Mib object is deprecated and no longer supported." ::= { mmToUSBIntfVpdEntry 3 } mmToUSBIntfVpdRevisonNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD revision number. NOTE: This Mib object is deprecated and no longer supported." ::= { mmToUSBIntfVpdEntry 4 } mmToUSBIntfVpdFilename OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD file name. NOTE: This Mib object is deprecated and no longer supported." ::= { mmToUSBIntfVpdEntry 5 } mmToUSBIntfVpdBuildDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Firmware VPD build date. NOTE: This Mib object is deprecated and no longer supported." ::= { mmToUSBIntfVpdEntry 6 } -- ******************************************************************************** -- System Component Level VPD Activity log -- ******************************************************************************** inventoryManagementActivityVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF InventoryManagementActivityVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of system component hardware VPD activity log. For consistent results, view as a table and not as individual entries." ::= { vpdInformation 22 } inventoryManagementActivityVpdEntry OBJECT-TYPE SYNTAX InventoryManagementActivityVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "System component hardware VPD activity log entry. For consistent results, view as a table and not as individual entries." INDEX { componentLevelActivityVpdIndex } ::= { inventoryManagementActivityVpdTable 1 } InventoryManagementActivityVpdEntry ::= SEQUENCE { componentLevelActivityVpdIndex INTEGER, componentLevelActivityVpdFruNumber OCTET STRING, componentLevelActivityVpdSerialNumber OCTET STRING, componentLevelActivityVpdManufacturingId OCTET STRING, componentLevelActivityVpdBayNumber OCTET STRING, componentLevelActivityVpdAction OCTET STRING, componentLevelActivityVpdTimestamp OCTET STRING, componentLevelActivityVpdModuleName OCTET STRING } componentLevelActivityVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "System component level VPD activity log index. For consistent results, view as a table and not as individual entries." ::= { inventoryManagementActivityVpdEntry 1 } componentLevelActivityVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "System component level VPD activity log FRU number. For consistent results, view as a table and not as individual entries." ::= { inventoryManagementActivityVpdEntry 2 } componentLevelActivityVpdSerialNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "System component level VPD activity log serial number. For consistent results, view as a table and not as individual entries." ::= { inventoryManagementActivityVpdEntry 3 } componentLevelActivityVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "System component level VPD activity log manufacturing ID. For consistent results, view as a table and not as individual entries." ::= { inventoryManagementActivityVpdEntry 4 } componentLevelActivityVpdBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "System component level VPD activity log Bay number. For consistent results, view as a table and not as individual entries." ::= { inventoryManagementActivityVpdEntry 5 } componentLevelActivityVpdAction OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "System component level VPD activity log action (added/removed). For consistent results, view as a table and not as individual entries." ::= {inventoryManagementActivityVpdEntry 9 } componentLevelActivityVpdTimestamp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "System component level VPD activity log timestamp. For consistent results, view as a table and not as individual entries." ::= { inventoryManagementActivityVpdEntry 10 } componentLevelActivityVpdModuleName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The module name which this row is associated with. For consistent results, view as a table and not as individual entries." ::= { inventoryManagementActivityVpdEntry 12 } -- ******************************************************************************** -- Blade Hardware VPD -- ******************************************************************************** bladeHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 4 } bladeHardwareVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of VPD information for the blade hardware components. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpd 1 } bladeHardwareVpdEntry OBJECT-TYPE SYNTAX BladeHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade hardware VPD entry. For consistent results, view as a table and not as individual entries." INDEX { bladeHardwareVpdIndex } ::= { bladeHardwareVpdTable 1 } BladeHardwareVpdEntry ::= SEQUENCE { bladeHardwareVpdIndex INTEGER, bladeHardwareVpdBayNumber OCTET STRING, bladeHardwareVpdManufacturingId OCTET STRING, bladeHardwareVpdFruNumber OCTET STRING, bladeHardwareVpdHardwareRevision INTEGER, bladeHardwareVpdSerialNumber OCTET STRING, bladeHardwareVpdMachineType OCTET STRING, bladeHardwareVpdUuid OCTET STRING, bladeHardwareVpdManufDate OCTET STRING, bladeHardwareVpdPartNumber OCTET STRING, bladeHardwareVpdFruSerial OCTET STRING, bladeHardwareVpdMachineModel OCTET STRING, bladeHardwareVpdManufacturingIDNumber OCTET STRING, bladeHardwareVpdProductId OCTET STRING, bladeHardwareVpdSubManufacturerId OCTET STRING, bladeHardwareVpdClei OCTET STRING, bladeHardwareVpdHardwareRevisionString OCTET STRING, bladeDaughterVpdCardType INTEGER, bladeDaughterVpdManufacturingId OCTET STRING, bladeDaughterVpdFruNumber OCTET STRING, bladeDaughterVpdHardwareRevision INTEGER, bladeDaughterVpdSerialNumber OCTET STRING, bladeDaughterVpdMachineType OCTET STRING, bladeDaughterVpdUuid OCTET STRING, bladeDaughterVpdManufDate OCTET STRING, bladeDaughterVpdPartNumber OCTET STRING, bladeDaughterVpdFruSerial OCTET STRING, bladeDaughterVpdManufacturingIDNumber OCTET STRING, bladeDaughterVpdProductId OCTET STRING, bladeDaughterVpdSubManufacturerId OCTET STRING, bladeDaughterVpdClei OCTET STRING, bladeDaughterVpdHardwareRevisionString OCTET STRING } bladeHardwareVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade hardware VPD index. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 1 } bladeHardwareVpdBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade hardware VPD Bay number. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 2 } bladeHardwareVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 3 } bladeHardwareVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade hardware VPD FRU number. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 4 } bladeHardwareVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { bladeHardwareVpdEntry 5 } bladeHardwareVpdSerialNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade hardware VPD serial number. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 6 } bladeHardwareVpdMachineType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade hardware VPD machine type. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 7 } bladeHardwareVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade hardware VPD UUID. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 8 } bladeHardwareVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade hardware VPD Manufacture Date. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 9 } bladeHardwareVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade hardware VPD Part number. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 10 } bladeHardwareVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 11 } bladeHardwareVpdMachineModel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade hardware VPD machine model. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 12 } bladeHardwareVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade hardware VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 13 } bladeHardwareVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade hardware VPD product ID. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 14 } bladeHardwareVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 15 } bladeHardwareVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 16 } bladeHardwareVpdHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used." ::= { bladeHardwareVpdEntry 17 } bladeDaughterVpdCardType OBJECT-TYPE SYNTAX INTEGER { unknown(0), networkExpansion(1), storageExpansion(2), pciExpansion(3), genericExpansion(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) VPD type. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 20 } bladeDaughterVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) VPD manufacturing ID. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 21 } bladeDaughterVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) VPD FRU number. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 22 } bladeDaughterVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { bladeHardwareVpdEntry 23 } bladeDaughterVpdSerialNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) VPD Serial number. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 24 } bladeDaughterVpdMachineType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) VPD Machine type. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 25 } bladeDaughterVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) VPD UUID. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 26 } bladeDaughterVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) VPD Manufacture date. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 27 } bladeDaughterVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) VPD Part number. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 28 } bladeDaughterVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) VPD FRU Serial. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 29 } bladeDaughterVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 30 } bladeDaughterVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) VPD product ID. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 31 } bladeDaughterVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) VPD subsystem manufacturing ID. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 32 } bladeDaughterVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpdEntry 33 } bladeDaughterVpdHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used." ::= { bladeHardwareVpdEntry 34 } -- ******************************************************************************** -- Blade MAC Address VPD -- ******************************************************************************** bladeMACAddressVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeMACAddressVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of MAC addresses of the blade and its expansion cards (daughter cards). For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpd 2 } bladeMACAddressVpdEntry OBJECT-TYPE SYNTAX BladeMACAddressVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade MAC address entry. For consistent results, view as a table and not as individual entries." INDEX { bladeMACAddressVpdIndex } ::= { bladeMACAddressVpdTable 1 } BladeMACAddressVpdEntry ::= SEQUENCE { bladeMACAddressVpdIndex INTEGER, bladeMACAddress1Vpd OCTET STRING, bladeMACAddress2Vpd OCTET STRING, bladeMACAddress3Vpd OCTET STRING, bladeMACAddress4Vpd OCTET STRING, bladeMACAddress5Vpd OCTET STRING, bladeMACAddress6Vpd OCTET STRING, bladeMACAddress7Vpd OCTET STRING, bladeMACAddress8Vpd OCTET STRING, bladeDaughterCard1MACAddress1Vpd OCTET STRING, bladeDaughterCard1MACAddress2Vpd OCTET STRING, bladeDaughterCard1MACAddress3Vpd OCTET STRING, bladeDaughterCard1MACAddress4Vpd OCTET STRING, bladeDaughterCard1MACAddress5Vpd OCTET STRING, bladeDaughterCard1MACAddress6Vpd OCTET STRING, bladeDaughterCard1MACAddress7Vpd OCTET STRING, bladeDaughterCard1MACAddress8Vpd OCTET STRING, bladeDaughterCard2MACAddress1Vpd OCTET STRING, bladeDaughterCard2MACAddress2Vpd OCTET STRING, bladeDaughterCard2MACAddress3Vpd OCTET STRING, bladeDaughterCard2MACAddress4Vpd OCTET STRING, bladeDaughterCard2MACAddress5Vpd OCTET STRING, bladeDaughterCard2MACAddress6Vpd OCTET STRING, bladeDaughterCard2MACAddress7Vpd OCTET STRING, bladeDaughterCard2MACAddress8Vpd OCTET STRING, bladeDaughterCard3MACAddress1Vpd OCTET STRING, bladeDaughterCard3MACAddress2Vpd OCTET STRING, bladeDaughterCard3MACAddress3Vpd OCTET STRING, bladeDaughterCard3MACAddress4Vpd OCTET STRING, bladeDaughterCard3MACAddress5Vpd OCTET STRING, bladeDaughterCard3MACAddress6Vpd OCTET STRING, bladeDaughterCard3MACAddress7Vpd OCTET STRING, bladeDaughterCard3MACAddress8Vpd OCTET STRING, bladeDaughterCard4MACAddress1Vpd OCTET STRING, bladeDaughterCard4MACAddress2Vpd OCTET STRING, bladeDaughterCard4MACAddress3Vpd OCTET STRING, bladeDaughterCard4MACAddress4Vpd OCTET STRING, bladeDaughterCard4MACAddress5Vpd OCTET STRING, bladeDaughterCard4MACAddress6Vpd OCTET STRING, bladeDaughterCard4MACAddress7Vpd OCTET STRING, bladeDaughterCard4MACAddress8Vpd OCTET STRING, bladeDaughterCard5MACAddress1Vpd OCTET STRING, bladeDaughterCard5MACAddress2Vpd OCTET STRING, bladeDaughterCard5MACAddress3Vpd OCTET STRING, bladeDaughterCard5MACAddress4Vpd OCTET STRING, bladeDaughterCard5MACAddress5Vpd OCTET STRING, bladeDaughterCard5MACAddress6Vpd OCTET STRING, bladeDaughterCard5MACAddress7Vpd OCTET STRING, bladeDaughterCard5MACAddress8Vpd OCTET STRING, bladeHSDaughterCard1MACAddress1Vpd OCTET STRING, bladeHSDaughterCard1MACAddress2Vpd OCTET STRING, bladeHSDaughterCard1MACAddress3Vpd OCTET STRING, bladeHSDaughterCard1MACAddress4Vpd OCTET STRING, bladeHSDaughterCard1MACAddress5Vpd OCTET STRING, bladeHSDaughterCard1MACAddress6Vpd OCTET STRING, bladeHSDaughterCard1MACAddress7Vpd OCTET STRING, bladeHSDaughterCard1MACAddress8Vpd OCTET STRING, bladeHSDaughterCard1MACAddress9Vpd OCTET STRING, bladeHSDaughterCard1MACAddress10Vpd OCTET STRING, bladeHSDaughterCard1MACAddress11Vpd OCTET STRING, bladeHSDaughterCard1MACAddress12Vpd OCTET STRING, bladeHSDaughterCard1MACAddress13Vpd OCTET STRING, bladeHSDaughterCard1MACAddress14Vpd OCTET STRING, bladeHSDaughterCard1MACAddress15Vpd OCTET STRING, bladeHSDaughterCard1MACAddress16Vpd OCTET STRING, bladeSideCardMACAddress1Vpd OCTET STRING, bladeSideCardMACAddress2Vpd OCTET STRING, bladeSideCardMACAddress3Vpd OCTET STRING, bladeSideCardMACAddress4Vpd OCTET STRING, bladeSideCardMACAddress5Vpd OCTET STRING, bladeSideCardMACAddress6Vpd OCTET STRING, bladeSideCardMACAddress7Vpd OCTET STRING, bladeSideCardMACAddress8Vpd OCTET STRING } bladeMACAddressVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade index. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 1 } bladeMACAddress1Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade MAC address 1. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 2 } bladeMACAddress2Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade MAC address 2. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 3 } bladeMACAddress3Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade MAC address 3. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 4 } bladeMACAddress4Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade MAC address 4. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 5 } bladeMACAddress5Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade MAC address 5. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 6 } bladeMACAddress6Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade MAC address 6. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 7 } bladeMACAddress7Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade MAC address 7. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 8 } bladeMACAddress8Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade MAC address 8. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 9 } bladeDaughterCard1MACAddress1Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 1 MAC address 1. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 10 } bladeDaughterCard1MACAddress2Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 1 MAC address 2. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 11 } bladeDaughterCard1MACAddress3Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 1 MAC address 3. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 12 } bladeDaughterCard1MACAddress4Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 1 MAC address 4. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 13 } bladeDaughterCard1MACAddress5Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 1 MAC address 5. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 14 } bladeDaughterCard1MACAddress6Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 1 MAC address 6. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 15 } bladeDaughterCard1MACAddress7Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 1 MAC address 7. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 16 } bladeDaughterCard1MACAddress8Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 1 MAC address 8. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 17 } bladeDaughterCard2MACAddress1Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 2 MAC address 1. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 18 } bladeDaughterCard2MACAddress2Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 2 MAC address 2. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 19 } bladeDaughterCard2MACAddress3Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 2 MAC address 3. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 20 } bladeDaughterCard2MACAddress4Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 2 MAC address 4. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 21 } bladeDaughterCard2MACAddress5Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 2 MAC address 5. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 22 } bladeDaughterCard2MACAddress6Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 2 MAC address 6. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 23 } bladeDaughterCard2MACAddress7Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 2 MAC address 7. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 24 } bladeDaughterCard2MACAddress8Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 2 MAC address 8. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 25 } bladeDaughterCard3MACAddress1Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 3 MAC address 1. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 26 } bladeDaughterCard3MACAddress2Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 3 MAC address 2. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 27 } bladeDaughterCard3MACAddress3Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 3 MAC address 3. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 28 } bladeDaughterCard3MACAddress4Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 3 MAC address 4. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 29 } bladeDaughterCard3MACAddress5Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 3 MAC address 5. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 30 } bladeDaughterCard3MACAddress6Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 3 MAC address 6. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 31 } bladeDaughterCard3MACAddress7Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 3 MAC address 7. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 32 } bladeDaughterCard3MACAddress8Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 3 MAC address 8. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 33 } bladeDaughterCard4MACAddress1Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 4 MAC address 1. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 34 } bladeDaughterCard4MACAddress2Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 4 MAC address 2. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 35 } bladeDaughterCard4MACAddress3Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 4 MAC address 3. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 36 } bladeDaughterCard4MACAddress4Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 4 MAC address 4. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 37 } bladeDaughterCard4MACAddress5Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 4 MAC address 5. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 38 } bladeDaughterCard4MACAddress6Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 4 MAC address 6. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 39 } bladeDaughterCard4MACAddress7Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 4 MAC address 7. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 40 } bladeDaughterCard4MACAddress8Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 4 MAC address 8. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 41 } bladeDaughterCard5MACAddress1Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 5 MAC address 1. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 42 } bladeDaughterCard5MACAddress2Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 5 MAC address 2. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 43 } bladeDaughterCard5MACAddress3Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 5 MAC address 3. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 44} bladeDaughterCard5MACAddress4Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 5 MAC address 4. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 45 } bladeDaughterCard5MACAddress5Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 5 MAC address 5. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 46 } bladeDaughterCard5MACAddress6Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 5 MAC address 6. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 47 } bladeDaughterCard5MACAddress7Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 5 MAC address 7. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 48 } bladeDaughterCard5MACAddress8Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) 5 MAC address 8. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 49 } bladeHSDaughterCard1MACAddress1Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade high speed expansion card (daughter card) 1 MAC address 1. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 100 } bladeHSDaughterCard1MACAddress2Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade high speed expansion card (daughter card) 1 MAC address 2. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 101 } bladeHSDaughterCard1MACAddress3Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade high speed expansion card (daughter card) 1 MAC address 3. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 102} bladeHSDaughterCard1MACAddress4Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade high speed expansion card (daughter card) 1 MAC address 4. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 103 } bladeHSDaughterCard1MACAddress5Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade high speed expansion card (daughter card) 1 MAC address 5. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 104 } bladeHSDaughterCard1MACAddress6Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade high speed expansion card (daughter card) 1 MAC address 6. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 105 } bladeHSDaughterCard1MACAddress7Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade high speed expansion card (daughter card) 1 MAC address 7. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 106 } bladeHSDaughterCard1MACAddress8Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade high speed expansion card (daughter card) 1 MAC address 8. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 107 } bladeHSDaughterCard1MACAddress9Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade high speed expansion card (daughter card) 1 MAC address 9. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 108 } bladeHSDaughterCard1MACAddress10Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade high speed expansion card (daughter card) 1 MAC address 10. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 109 } bladeHSDaughterCard1MACAddress11Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade high speed expansion card (daughter card) 1 MAC address 11. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 110 } bladeHSDaughterCard1MACAddress12Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade high speed expansion card (daughter card) 1 MAC address 12. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 111 } bladeHSDaughterCard1MACAddress13Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade high speed expansion card (daughter card) 1 MAC address 13. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 112 } bladeHSDaughterCard1MACAddress14Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade high speed expansion card (daughter card) 1 MAC address 14. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 113 } bladeHSDaughterCard1MACAddress15Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade high speed expansion card (daughter card) 1 MAC address 15. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 114 } bladeHSDaughterCard1MACAddress16Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade high speed expansion card (daughter card) 1 MAC address 16. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 115 } bladeSideCardMACAddress1Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card MAC address 1. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 164 } bladeSideCardMACAddress2Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card MAC address 2. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 165 } bladeSideCardMACAddress3Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card MAC address 3. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 166 } bladeSideCardMACAddress4Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card MAC address 4. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 167 } bladeSideCardMACAddress5Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card MAC address 5. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 168 } bladeSideCardMACAddress6Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card MAC address 6. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 169 } bladeSideCardMACAddress7Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card MAC address 7. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 170 } bladeSideCardMACAddress8Vpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card MAC address 8. For consistent results, view as a table and not as individual entries." ::= { bladeMACAddressVpdEntry 171 } -- ******************************************************************************** -- Blade Expansion Board VPD -- ******************************************************************************** bladeExpBoardVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeExpBoardVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of VPD information for the blade expansion board components. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpd 3 } bladeExpBoardVpdEntry OBJECT-TYPE SYNTAX BladeExpBoardVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade expansion board VPD entry. For consistent results, view as a table and not as individual entries." INDEX { bladeExpBoardVpdIndex } ::= { bladeExpBoardVpdTable 1 } BladeExpBoardVpdEntry ::= SEQUENCE { bladeExpBoardVpdIndex INTEGER, bladeExpBoardVpdBayNumber OCTET STRING, bladeExpBoardVpdManufacturingId OCTET STRING, bladeExpBoardVpdFruNumber OCTET STRING, bladeExpBoardVpdHardwareRevision INTEGER, bladeExpBoardVpdSerialNumber OCTET STRING, bladeExpBoardVpdMachineType OCTET STRING, bladeExpBoardVpdUuid OCTET STRING, bladeExpBoardVpdManufDate OCTET STRING, bladeExpBoardVpdPartNumber OCTET STRING, bladeExpBoardVpdFruSerial OCTET STRING, bladeExpBoardVpdMachineModel OCTET STRING, bladeExpBoardVpdManufacturingIDNumber OCTET STRING, bladeExpBoardVpdProductId OCTET STRING, bladeExpBoardVpdSubManufacturerId OCTET STRING, bladeExpBoardVpdClei OCTET STRING, bladeExpBoardVpdBladeBayNumber OCTET STRING, bladeExpBoardVpdCardType INTEGER, bladeExpBoardVpdCardSubType INTEGER, bladeExpBoardVpdHardwareRevisionString OCTET STRING } bladeExpBoardVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion board VPD index. For consistent results, view as a table and not as individual entries." ::= { bladeExpBoardVpdEntry 1 } bladeExpBoardVpdBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion board VPD Bay number. For consistent results, view as a table and not as individual entries." ::= { bladeExpBoardVpdEntry 2 } bladeExpBoardVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion board VPD manufacturing ID. For consistent results, view as a table and not as individual entries." ::= { bladeExpBoardVpdEntry 3 } bladeExpBoardVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion board VPD FRU number. For consistent results, view as a table and not as individual entries." ::= { bladeExpBoardVpdEntry 4 } bladeExpBoardVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion board VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { bladeExpBoardVpdEntry 5 } bladeExpBoardVpdSerialNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion board VPD serial number. For consistent results, view as a table and not as individual entries." ::= { bladeExpBoardVpdEntry 6 } bladeExpBoardVpdMachineType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion board VPD machine type. For consistent results, view as a table and not as individual entries." ::= { bladeExpBoardVpdEntry 7 } bladeExpBoardVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion board VPD UUID. For consistent results, view as a table and not as individual entries." ::= { bladeExpBoardVpdEntry 8 } bladeExpBoardVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion board VPD Manufacture Date. For consistent results, view as a table and not as individual entries." ::= { bladeExpBoardVpdEntry 9 } bladeExpBoardVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion board VPD Part number. For consistent results, view as a table and not as individual entries." ::= { bladeExpBoardVpdEntry 10 } bladeExpBoardVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion board VPD FRU serial number. For consistent results, view as a table and not as individual entries." ::= { bladeExpBoardVpdEntry 11 } bladeExpBoardVpdMachineModel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion board VPD machine model. For consistent results, view as a table and not as individual entries." ::= { bladeExpBoardVpdEntry 12 } bladeExpBoardVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion board VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries." ::= { bladeExpBoardVpdEntry 13 } bladeExpBoardVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion board VPD Product ID. For consistent results, view as a table and not as individual entries." ::= { bladeExpBoardVpdEntry 14 } bladeExpBoardVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion board VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { bladeExpBoardVpdEntry 15 } bladeExpBoardVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion board VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries." ::= { bladeExpBoardVpdEntry 16 } bladeExpBoardVpdBladeBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade bay number of the blade expansion board. For consistent results, view as a table and not as individual entries." ::= { bladeExpBoardVpdEntry 19 } bladeExpBoardVpdCardType OBJECT-TYPE SYNTAX INTEGER { unknown(0), storageExpansion(1), pciExpansion(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion board VPD type. For consistent results, view as a table and not as individual entries." ::= { bladeExpBoardVpdEntry 20 } bladeExpBoardVpdCardSubType OBJECT-TYPE SYNTAX INTEGER { unknown(0), bse1(1), bse2(2), bse3(3), peu1(11), peu2(12), peu3(13), bie(21) } ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion board VPD subtype. Describes the expansion board type with more granularity. bse1,bse2,bse3 = Blade Storage Expansion (1st, 2nd, and 3rd Generations), peu1 = PCI Expansion (1st Generation), peu2 = PCI Expansion Unit II, peu3 = bpe3 = PCI Express Expansion Unit, bie= Blade I/O Expansion For consistent results, view as a table and not as individual entries." ::= { bladeExpBoardVpdEntry 21 } bladeExpBoardVpdHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion board VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used." ::= { bladeExpBoardVpdEntry 22 } -- ******************************************************************************** -- Blade Side Card VPD -- ******************************************************************************** bladeSideCardVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeSideCardVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of VPD information for the blade side card components. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpd 4 } bladeSideCardVpdEntry OBJECT-TYPE SYNTAX BladeSideCardVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade side card VPD entry. For consistent results, view as a table and not as individual entries." INDEX { bladeSideCardVpdIndex } ::= { bladeSideCardVpdTable 1 } BladeSideCardVpdEntry ::= SEQUENCE { bladeSideCardVpdIndex INTEGER, bladeSideCardVpdBayNumber OCTET STRING, bladeSideCardVpdManufacturingId OCTET STRING, bladeSideCardVpdFruNumber OCTET STRING, bladeSideCardVpdHardwareRevision INTEGER, bladeSideCardVpdSerialNumber OCTET STRING, bladeSideCardVpdMachineType OCTET STRING, bladeSideCardVpdUuid OCTET STRING, bladeSideCardVpdManufDate OCTET STRING, bladeSideCardVpdPartNumber OCTET STRING, bladeSideCardVpdFruSerial OCTET STRING, bladeSideCardVpdMachineModel OCTET STRING, bladeSideCardVpdManufacturingIDNumber OCTET STRING, bladeSideCardVpdProductId OCTET STRING, bladeSideCardVpdSubManufacturerId OCTET STRING, bladeSideCardVpdClei OCTET STRING, bladeSideCardVpdBladeBayNumber OCTET STRING, bladeSideCardVpdHardwareRevisionString OCTET STRING } bladeSideCardVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card VPD index. For consistent results, view as a table and not as individual entries." ::= { bladeSideCardVpdEntry 1 } bladeSideCardVpdBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card VPD Bay number. For consistent results, view as a table and not as individual entries." ::= { bladeSideCardVpdEntry 2 } bladeSideCardVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card VPD manufacturing ID. For consistent results, view as a table and not as individual entries." ::= { bladeSideCardVpdEntry 3 } bladeSideCardVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card VPD FRU number. For consistent results, view as a table and not as individual entries." ::= { bladeSideCardVpdEntry 4 } bladeSideCardVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { bladeSideCardVpdEntry 5 } bladeSideCardVpdSerialNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card VPD serial number. For consistent results, view as a table and not as individual entries." ::= { bladeSideCardVpdEntry 6 } bladeSideCardVpdMachineType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card VPD machine type. For consistent results, view as a table and not as individual entries." ::= { bladeSideCardVpdEntry 7 } bladeSideCardVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card VPD UUID. For consistent results, view as a table and not as individual entries." ::= { bladeSideCardVpdEntry 8 } bladeSideCardVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card VPD Manufacture Date. For consistent results, view as a table and not as individual entries." ::= { bladeSideCardVpdEntry 9 } bladeSideCardVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card VPD Part number. For consistent results, view as a table and not as individual entries." ::= { bladeSideCardVpdEntry 10 } bladeSideCardVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card VPD FRU serial number. For consistent results, view as a table and not as individual entries." ::= { bladeSideCardVpdEntry 11 } bladeSideCardVpdMachineModel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card VPD machine model. For consistent results, view as a table and not as individual entries." ::= { bladeSideCardVpdEntry 12 } bladeSideCardVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries." ::= { bladeSideCardVpdEntry 13 } bladeSideCardVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card VPD Product ID. For consistent results, view as a table and not as individual entries." ::= { bladeSideCardVpdEntry 14 } bladeSideCardVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { bladeSideCardVpdEntry 15 } bladeSideCardVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries." ::= { bladeSideCardVpdEntry 16 } bladeSideCardVpdBladeBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade bay number of the blade side card. For consistent results, view as a table and not as individual entries." ::= { bladeSideCardVpdEntry 19 } bladeSideCardVpdHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade side card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used." ::= { bladeSideCardVpdEntry 20 } -- ******************************************************************************** -- Blade Expansion Card VPD -- ******************************************************************************** bladeExpCardVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeExpCardVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of VPD information for the blade expansion card components. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpd 5 } bladeExpCardVpdEntry OBJECT-TYPE SYNTAX BladeExpCardVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade expansion card VPD entry. For consistent results, view as a table and not as individual entries." INDEX { bladeExpCardVpdIndex } ::= { bladeExpCardVpdTable 1 } BladeExpCardVpdEntry ::= SEQUENCE { bladeExpCardVpdIndex INTEGER, bladeExpCardVpdBayNumber OCTET STRING, bladeExpCardVpdManufacturingId OCTET STRING, bladeExpCardVpdFruNumber OCTET STRING, bladeExpCardVpdHardwareRevision INTEGER, bladeExpCardVpdSerialNumber OCTET STRING, bladeExpCardVpdMachineType OCTET STRING, bladeExpCardVpdUuid OCTET STRING, bladeExpCardVpdManufDate OCTET STRING, bladeExpCardVpdPartNumber OCTET STRING, bladeExpCardVpdFruSerial OCTET STRING, bladeExpCardVpdMachineModel OCTET STRING, bladeExpCardVpdManufacturingIDNumber OCTET STRING, bladeExpCardVpdProductId OCTET STRING, bladeExpCardVpdSubManufacturerId OCTET STRING, bladeExpCardVpdClei OCTET STRING, bladeExpCardVpdBladeBayNumber OCTET STRING, bladeExpCardVpdCardTypeInfo INTEGER, bladeExpCardVpdHighSpeed INTEGER, bladeExpCardVpdHardwareRevisionString OCTET STRING } bladeExpCardVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card VPD index. For consistent results, view as a table and not as individual entries." ::= { bladeExpCardVpdEntry 1 } bladeExpCardVpdBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card VPD Bay number. For consistent results, view as a table and not as individual entries." ::= { bladeExpCardVpdEntry 2 } bladeExpCardVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card VPD manufacturing ID. For consistent results, view as a table and not as individual entries." ::= { bladeExpCardVpdEntry 3 } bladeExpCardVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card VPD FRU number. For consistent results, view as a table and not as individual entries." ::= { bladeExpCardVpdEntry 4 } bladeExpCardVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { bladeExpCardVpdEntry 5 } bladeExpCardVpdSerialNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card VPD serial number. For consistent results, view as a table and not as individual entries." ::= { bladeExpCardVpdEntry 6 } bladeExpCardVpdMachineType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card VPD machine type. For consistent results, view as a table and not as individual entries." ::= { bladeExpCardVpdEntry 7 } bladeExpCardVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card VPD UUID. For consistent results, view as a table and not as individual entries." ::= { bladeExpCardVpdEntry 8 } bladeExpCardVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card VPD Manufacture Date. For consistent results, view as a table and not as individual entries." ::= { bladeExpCardVpdEntry 9 } bladeExpCardVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card VPD Part number. For consistent results, view as a table and not as individual entries." ::= { bladeExpCardVpdEntry 10 } bladeExpCardVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card VPD FRU serial number. For consistent results, view as a table and not as individual entries." ::= { bladeExpCardVpdEntry 11 } bladeExpCardVpdMachineModel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card VPD machine model. For consistent results, view as a table and not as individual entries." ::= { bladeExpCardVpdEntry 12 } bladeExpCardVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries." ::= { bladeExpCardVpdEntry 13 } bladeExpCardVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card VPD Product ID. For consistent results, view as a table and not as individual entries." ::= { bladeExpCardVpdEntry 14 } bladeExpCardVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { bladeExpCardVpdEntry 15 } bladeExpCardVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries." ::= { bladeExpCardVpdEntry 16 } bladeExpCardVpdBladeBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade bay number of the blade expansion card. For consistent results, view as a table and not as individual entries." ::= { bladeExpCardVpdEntry 19 } bladeExpCardVpdCardTypeInfo OBJECT-TYPE SYNTAX INTEGER { unknown(0), bladeEthernetExpCard(1), bladeFiberChannelExpCard(2), serialPortExpCard(3), bladeOpticalPassThrough(4), bladeInfinibandExpCard(5), bladeIscsiExpCard(6), bladeGenericExpCard(7), bladeNetworkCFFeExpCard(8), bladeSASConnectivityCard(9), bladeSATAConnectivityCard(10), bladeNetworkCFFzExpCard(11), bladeNetworkCNAExpCard(12), bladeSSDExpCard(13), bladePCIExp(14), bladeGraphicsExp(15), bladeIOExp(16), bladeMemoryExp(17), bladeProcessorExp(18), bladeGenericExp(19) } ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) VPD type code that describes the expansion card. For consistent results, view as a table and not as individual entries. NOTE: The CFFe expansion card is also referred to as a CFFh expansion card." ::= { bladeExpCardVpdEntry 21 } bladeExpCardVpdHighSpeed OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card (daughter card) VPD high speed that indicates whether the expansion card is high speed or not. For consistent results, view as a table and not as individual entries." ::= { bladeExpCardVpdEntry 22 } bladeExpCardVpdHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade expansion card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used." ::= { bladeExpCardVpdEntry 23 } -- ******************************************************************************** -- Blade cKVM card VPD -- ******************************************************************************** bladecKVMCardVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF BladecKVMCardVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of VPD information for the blade concurrent keyboard, video, and mouse (cKVM) card components. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpd 6 } bladecKVMCardVpdEntry OBJECT-TYPE SYNTAX BladecKVMCardVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade concurrent keyboard, video, and mouse (cKVM) card VPD entry. For consistent results, view as a table and not as individual entries." INDEX { bladecKVMCardVpdIndex } ::= { bladecKVMCardVpdTable 1 } BladecKVMCardVpdEntry ::= SEQUENCE { bladecKVMCardVpdIndex INTEGER, bladecKVMCardVpdBayNumber OCTET STRING, bladecKVMCardVpdManufacturingId OCTET STRING, bladecKVMCardVpdFruNumber OCTET STRING, bladecKVMCardVpdHardwareRevision INTEGER, bladecKVMCardVpdSerialNumber OCTET STRING, bladecKVMCardVpdMachineType OCTET STRING, bladecKVMCardVpdUuid OCTET STRING, bladecKVMCardVpdManufDate OCTET STRING, bladecKVMCardVpdPartNumber OCTET STRING, bladecKVMCardVpdFruSerial OCTET STRING, bladecKVMCardVpdMachineModel OCTET STRING, bladecKVMCardVpdManufacturingIDNumber OCTET STRING, bladecKVMCardVpdProductId OCTET STRING, bladecKVMCardVpdSubManufacturerId OCTET STRING, bladecKVMCardVpdClei OCTET STRING, bladecKVMCardVpdHardwareRevisionString OCTET STRING } bladecKVMCardVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade concurrent keyboard mouse video (cKVM) card VPD index. For consistent results, view as a table and not as individual entries." ::= { bladecKVMCardVpdEntry 1 } bladecKVMCardVpdBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade concurrent keyboard video mouse (cKVM) card VPD Bay number. For consistent results, view as a table and not as individual entries." ::= { bladecKVMCardVpdEntry 2 } bladecKVMCardVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade concurrent keyboard video mouse (cKVM) card VPD manufacturing ID. For consistent results, view as a table and not as individual entries." ::= { bladecKVMCardVpdEntry 3 } bladecKVMCardVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade concurrent keyboard video mouse (cKVM) card VPD FRU number. For consistent results, view as a table and not as individual entries." ::= { bladecKVMCardVpdEntry 4 } bladecKVMCardVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade concurrent keyboard video mouse (cKVM) card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { bladecKVMCardVpdEntry 5 } bladecKVMCardVpdSerialNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade concurrent keyboard video mouse (cKVM) card VPD serial number. For consistent results, view as a table and not as individual entries." ::= { bladecKVMCardVpdEntry 6 } bladecKVMCardVpdMachineType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade concurrent keyboard video mouse (cKVM) card VPD machine type. For consistent results, view as a table and not as individual entries." ::= { bladecKVMCardVpdEntry 7 } bladecKVMCardVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade concurrent keyboard video mouse (cKVM) card VPD UUID. For consistent results, view as a table and not as individual entries." ::= { bladecKVMCardVpdEntry 8 } bladecKVMCardVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade concurrent keyboard video mouse (cKVM) card VPD Manufacture Date. For consistent results, view as a table and not as individual entries." ::= { bladecKVMCardVpdEntry 9 } bladecKVMCardVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade concurrent keyboard video mouse (cKVM) card VPD Part number. For consistent results, view as a table and not as individual entries." ::= { bladecKVMCardVpdEntry 10 } bladecKVMCardVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade concurrent keyboard video mouse (cKVM) card VPD FRU serial number. For consistent results, view as a table and not as individual entries." ::= { bladecKVMCardVpdEntry 11 } bladecKVMCardVpdMachineModel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade concurrent keyboard video mouse (cKVM) card VPD machine model. For consistent results, view as a table and not as individual entries." ::= { bladecKVMCardVpdEntry 12 } bladecKVMCardVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade concurrent keyboard video mouse (cKVM) card VPD manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { bladecKVMCardVpdEntry 13 } bladecKVMCardVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade concurrent keyboard video mouse (cKVM) card VPD Product ID. For consistent results, view as a table and not as individual entries." ::= { bladecKVMCardVpdEntry 14 } bladecKVMCardVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade concurrent keyboard video mouse (cKVM) card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { bladecKVMCardVpdEntry 15 } bladecKVMCardVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade concurrent keyboard video mouse (cKVM) card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries." ::= { bladecKVMCardVpdEntry 16 } bladecKVMCardVpdHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade concurrent keyboard video mouse (cKVM) card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used." ::= { bladecKVMCardVpdEntry 17 } -- ******************************************************************************** -- Table for the blade and expansion card WWN/GUIDs -- ******************************************************************************** bladeAndExpCardWwnGuidVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeAndExpCardWwnGuidVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of World Wide Names (WWN), Global Unique IDs (GUID) and Serial Attach SCSI IDs (SAS) of the blade server and its expansion cards (daughter cards). For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpd 7 } bladeAndExpCardWwnGuidVpdEntry OBJECT-TYPE SYNTAX BladeAndExpCardWwnGuidVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade WWN/GUID entries. For consistent results, view as a table and not as individual entries." INDEX { bladeAndExpCardWwnGuidVpdIndex } ::= { bladeAndExpCardWwnGuidVpdTable 1 } BladeAndExpCardWwnGuidVpdEntry ::= SEQUENCE { bladeAndExpCardWwnGuidVpdIndex INTEGER, bladeAndExpCardWwnGuidVpdBayNumber OCTET STRING, bladeAndExpCardWwnGuidVpdName OCTET STRING, bladeAndExpCardWwnGuidVpdBladeBayNumber OCTET STRING, bladeAndExpCardWwnGuidVpdType INTEGER, bladeAndExpCardWwnGuidVpd1 OCTET STRING, bladeAndExpCardWwnGuidVpd2 OCTET STRING, bladeAndExpCardWwnGuidVpd3 OCTET STRING, bladeAndExpCardWwnGuidVpd4 OCTET STRING, bladeAndExpCardWwnGuidVpd5 OCTET STRING, bladeAndExpCardWwnGuidVpd6 OCTET STRING, bladeAndExpCardWwnGuidVpd7 OCTET STRING, bladeAndExpCardWwnGuidVpd8 OCTET STRING } bladeAndExpCardWwnGuidVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade or expansion card index. For consistent results, view as a table and not as individual entries." ::= { bladeAndExpCardWwnGuidVpdEntry 1 } bladeAndExpCardWwnGuidVpdBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade or expansion card VPD bay number. For consistent results, view as a table and not as individual entries." ::= { bladeAndExpCardWwnGuidVpdEntry 2 } bladeAndExpCardWwnGuidVpdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the blade or expansion card. For consistent results, view as a table and not as individual entries." ::= { bladeAndExpCardWwnGuidVpdEntry 3 } bladeAndExpCardWwnGuidVpdBladeBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "For expansion cards, it's the blade bay number of the blade expansion card. For blades, it's the bay number of the blade. For consistent results, view as a table and not as individual entries." ::= { bladeAndExpCardWwnGuidVpdEntry 4 } bladeAndExpCardWwnGuidVpdType OBJECT-TYPE SYNTAX INTEGER { notAvailable(0), wwn(1), guid(2), sas(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Blade or expansion card WWN/GUID/SAS Type. For consistent results, view as a table and not as individual entries." ::= { bladeAndExpCardWwnGuidVpdEntry 5 } bladeAndExpCardWwnGuidVpd1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade or expansion card WWN/GUID 1. For consistent results, view as a table and not as individual entries." ::= { bladeAndExpCardWwnGuidVpdEntry 6 } bladeAndExpCardWwnGuidVpd2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade or expansion card WWN/GUID 2. For consistent results, view as a table and not as individual entries." ::= { bladeAndExpCardWwnGuidVpdEntry 7 } bladeAndExpCardWwnGuidVpd3 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade or expansion card WWN/GUID 3. For consistent results, view as a table and not as individual entries." ::= { bladeAndExpCardWwnGuidVpdEntry 8 } bladeAndExpCardWwnGuidVpd4 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade or expansion card WWN/GUID 4. For consistent results, view as a table and not as individual entries." ::= { bladeAndExpCardWwnGuidVpdEntry 9 } bladeAndExpCardWwnGuidVpd5 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade or expansion card WWN/GUID 5. For consistent results, view as a table and not as individual entries." ::= { bladeAndExpCardWwnGuidVpdEntry 10 } bladeAndExpCardWwnGuidVpd6 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade or expansion card WWN/GUID 6. For consistent results, view as a table and not as individual entries." ::= { bladeAndExpCardWwnGuidVpdEntry 11 } bladeAndExpCardWwnGuidVpd7 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade or expansion card WWN/GUID 7. For consistent results, view as a table and not as individual entries." ::= { bladeAndExpCardWwnGuidVpdEntry 12 } bladeAndExpCardWwnGuidVpd8 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade or expansion card WWN/GUID 8. For consistent results, view as a table and not as individual entries." ::= { bladeAndExpCardWwnGuidVpdEntry 13 } -- ******************************************************************************** -- Blade managerment card vpd -- ******************************************************************************** bladeManagementCardVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeManagementCardVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of VPD information for the blade management card component. For consistent results, view as a table and not as individual entries." ::= { bladeHardwareVpd 8 } bladeManagementCardVpdEntry OBJECT-TYPE SYNTAX BladeManagementCardVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade management card VPD entry. For consistent results, view as a table and not as individual entries." INDEX { bladeManagementCardVpdIndex } ::= { bladeManagementCardVpdTable 1 } BladeManagementCardVpdEntry ::= SEQUENCE { bladeManagementCardVpdIndex INTEGER, bladeManagementCardVpdBayNumber OCTET STRING, bladeManagementCardVpdManufacturingId OCTET STRING, bladeManagementCardVpdFruNumber OCTET STRING, bladeManagementCardVpdHardwareRevision INTEGER, bladeManagementCardVpdSerialNumber OCTET STRING, bladeManagementCardVpdMachineType OCTET STRING, bladeManagementCardVpdUuid OCTET STRING, bladeManagementCardVpdManufDate OCTET STRING, bladeManagementCardVpdPartNumber OCTET STRING, bladeManagementCardVpdFruSerial OCTET STRING, bladeManagementCardVpdMachineModel OCTET STRING, bladeManagementCardVpdManufacturingIDNumber OCTET STRING, bladeManagementCardVpdProductId OCTET STRING, bladeManagementCardVpdSubManufacturerId OCTET STRING, bladeManagementCardVpdClei OCTET STRING, bladeManagementCardVpdHardwareRevisionString OCTET STRING } bladeManagementCardVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade management card VPD index. For consistent results, view as a table and not as individual entries." ::= { bladeManagementCardVpdEntry 1 } bladeManagementCardVpdBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade management card VPD Bay number. For consistent results, view as a table and not as individual entries." ::= { bladeManagementCardVpdEntry 2 } bladeManagementCardVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade management card VPD manufacturing ID. For consistent results, view as a table and not as individual entries." ::= { bladeManagementCardVpdEntry 3 } bladeManagementCardVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade management card VPD FRU number. For consistent results, view as a table and not as individual entries." ::= { bladeManagementCardVpdEntry 4 } bladeManagementCardVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade management card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { bladeManagementCardVpdEntry 5 } bladeManagementCardVpdSerialNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade management card VPD serial number. For consistent results, view as a table and not as individual entries." ::= { bladeManagementCardVpdEntry 6 } bladeManagementCardVpdMachineType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade management card VPD machine type. For consistent results, view as a table and not as individual entries." ::= { bladeManagementCardVpdEntry 7 } bladeManagementCardVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade management card VPD UUID. For consistent results, view as a table and not as individual entries." ::= { bladeManagementCardVpdEntry 8 } bladeManagementCardVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade management card VPD Manufacture Date. For consistent results, view as a table and not as individual entries." ::= { bladeManagementCardVpdEntry 9 } bladeManagementCardVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade management card VPD Part number. For consistent results, view as a table and not as individual entries." ::= { bladeManagementCardVpdEntry 10 } bladeManagementCardVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade management card VPD FRU serial number. For consistent results, view as a table and not as individual entries." ::= { bladeManagementCardVpdEntry 11 } bladeManagementCardVpdMachineModel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade management card VPD machine model. For consistent results, view as a table and not as individual entries." ::= { bladeManagementCardVpdEntry 12 } bladeManagementCardVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade management card VPD manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { bladeManagementCardVpdEntry 13 } bladeManagementCardVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade management card VPD Product ID. For consistent results, view as a table and not as individual entries." ::= { bladeManagementCardVpdEntry 14 } bladeManagementCardVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade management card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { bladeManagementCardVpdEntry 15 } bladeManagementCardVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade management card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries." ::= { bladeManagementCardVpdEntry 16 } bladeManagementCardVpdHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blade management card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used." ::= { bladeManagementCardVpdEntry 17 } -- ******************************************************************************** -- System Firmware Level VPD -- ******************************************************************************** bladeFirmwareVpd OBJECT IDENTIFIER ::= { vpdInformation 5 } bladeBiosVPDTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeBiosVPDEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade firmware vital product data (VPD) information." ::= { bladeFirmwareVpd 1 } bladeBiosVPDEntry OBJECT-TYPE SYNTAX BladeBiosVPDEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade firmware VPD table entry" INDEX { bladeBiosVpdIndex } ::= { bladeBiosVPDTable 1 } BladeBiosVPDEntry ::= SEQUENCE { bladeBiosVpdIndex INTEGER, bladeBiosVpdId INTEGER, bladeBiosVpdExists INTEGER, bladeBiosVpdPowerState INTEGER, bladeBiosVpdName OCTET STRING, bladeBiosVpdBuildId OCTET STRING, bladeBiosVpdRevision OCTET STRING, bladeBiosVpdDate OCTET STRING, bladeBiosVpdLevelStatus OCTET STRING } bladeBiosVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade firmware VPD table index." ::= { bladeBiosVPDEntry 1 } bladeBiosVpdId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { bladeBiosVPDEntry 2 } bladeBiosVpdExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the server blade specified exists or not." ::= { bladeBiosVPDEntry 3 } bladeBiosVpdPowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), standby(3), hibernate(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the power state of the blade specified." ::= { bladeBiosVPDEntry 4 } bladeBiosVpdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the blade as a null terminated string." ::= { bladeBiosVPDEntry 5 } bladeBiosVpdBuildId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The build ID for the blade firmware." ::= { bladeBiosVPDEntry 6 } bladeBiosVpdRevision OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The revision of the blade firmware." ::= { bladeBiosVPDEntry 7 } bladeBiosVpdDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The date of the blade firmware." ::= { bladeBiosVPDEntry 8 } bladeBiosVpdLevelStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The level status of the blade bios firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID)." ::= { bladeBiosVPDEntry 9 } bladeDiagsVPDTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeDiagsVPDEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade firmware vital product data (VPD) information." ::= { bladeFirmwareVpd 2 } bladeDiagsVPDEntry OBJECT-TYPE SYNTAX BladeDiagsVPDEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade firmware VPD table entry" INDEX { bladeDiagsVpdIndex } ::= { bladeDiagsVPDTable 1 } BladeDiagsVPDEntry ::= SEQUENCE { bladeDiagsVpdIndex INTEGER, bladeDiagsVpdId INTEGER, bladeDiagsVpdExists INTEGER, bladeDiagsVpdPowerState INTEGER, bladeDiagsVpdName OCTET STRING, bladeDiagsVpdBuildId OCTET STRING, bladeDiagsVpdRevision OCTET STRING, bladeDiagsVpdDate OCTET STRING, bladeDiagsVpdLevelStatus OCTET STRING } bladeDiagsVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade firmware VPD table index." ::= { bladeDiagsVPDEntry 1 } bladeDiagsVpdId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { bladeDiagsVPDEntry 2 } bladeDiagsVpdExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the server blade specified exists or not." ::= { bladeDiagsVPDEntry 3 } bladeDiagsVpdPowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), standby(3), hibernate(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the power state of the blade specified." ::= { bladeDiagsVPDEntry 4 } bladeDiagsVpdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the blade as a null terminated string." ::= { bladeDiagsVPDEntry 5 } bladeDiagsVpdBuildId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The build ID for the blade firmware." ::= { bladeDiagsVPDEntry 6 } bladeDiagsVpdRevision OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The revision of the blade firmware." ::= { bladeDiagsVPDEntry 7 } bladeDiagsVpdDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The date of the blade firmware." ::= { bladeDiagsVPDEntry 8 } bladeDiagsVpdLevelStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The level status of the blade diagnostics firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID)." ::= { bladeDiagsVPDEntry 9 } bladeSysMgmtProcVPDTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeSysMgmtProcVPDEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade firmware vital product data (VPD) information." ::= { bladeFirmwareVpd 3 } bladeSysMgmtProcVPDEntry OBJECT-TYPE SYNTAX BladeSysMgmtProcVPDEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade firmware VPD table entry" INDEX { bladeSysMgmtProcVpdIndex } ::= { bladeSysMgmtProcVPDTable 1 } BladeSysMgmtProcVPDEntry ::= SEQUENCE { bladeSysMgmtProcVpdIndex INTEGER, bladeSysMgmtProcVpdId INTEGER, bladeSysMgmtProcVpdExists INTEGER, bladeSysMgmtProcVpdPowerState INTEGER, bladeSysMgmtProcVpdName OCTET STRING, bladeSysMgmtProcVpdBuildId OCTET STRING, bladeSysMgmtProcVpdRevision OCTET STRING, bladeSysMgmtProcVpdLevelStatus OCTET STRING } bladeSysMgmtProcVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade firmware VPD table index." ::= { bladeSysMgmtProcVPDEntry 1 } bladeSysMgmtProcVpdId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { bladeSysMgmtProcVPDEntry 2 } bladeSysMgmtProcVpdExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the server blade specified exists or not." ::= { bladeSysMgmtProcVPDEntry 3 } bladeSysMgmtProcVpdPowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), standby(3), hibernate(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the power state of the blade specified." ::= { bladeSysMgmtProcVPDEntry 4 } bladeSysMgmtProcVpdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the blade as a null terminated string." ::= { bladeSysMgmtProcVPDEntry 5 } bladeSysMgmtProcVpdBuildId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The build ID for the blade firmware." ::= { bladeSysMgmtProcVPDEntry 6 } bladeSysMgmtProcVpdRevision OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The revision of the blade firmware." ::= { bladeSysMgmtProcVPDEntry 7 } bladeSysMgmtProcVpdLevelStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The level status of the blade system management processor firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID)." ::= { bladeSysMgmtProcVPDEntry 8 } bladecKVMVPDTable OBJECT-TYPE SYNTAX SEQUENCE OF BladecKVMVPDEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade firmware vital product data (VPD) information." ::= { bladeFirmwareVpd 4 } bladecKVMVPDEntry OBJECT-TYPE SYNTAX BladecKVMVPDEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade firmware VPD table entry" INDEX { bladecKVMVpdIndex } ::= { bladecKVMVPDTable 1 } BladecKVMVPDEntry ::= SEQUENCE { bladecKVMVpdIndex INTEGER, bladecKVMVpdId INTEGER, bladecKVMVpdExists INTEGER, bladecKVMVpdPowerState INTEGER, bladecKVMVpdName OCTET STRING, bladecKVMVpdRevision OCTET STRING } bladecKVMVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade firmware VPD table index." ::= { bladecKVMVPDEntry 1 } bladecKVMVpdId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { bladecKVMVPDEntry 2 } bladecKVMVpdExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the blade specified exists or not." ::= { bladecKVMVPDEntry 3 } bladecKVMVpdPowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), standby(3), hibernate(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the power state of the blade specified." ::= { bladecKVMVPDEntry 4 } bladecKVMVpdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the blade as a null terminated string." ::= { bladecKVMVPDEntry 5 } bladecKVMVpdRevision OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The revision of the blade firmware." ::= { bladecKVMVPDEntry 7 } -- ******************************************************************************** -- Blade Firmware Build ID -- ******************************************************************************** bladeFWBuildIDs OBJECT IDENTIFIER ::= { bladeFirmwareVpd 5} bladeFWBuildIDTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeFWBuildIDEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Blade Firmware Build ID entries information." ::= { bladeFWBuildIDs 1 } bladeFWBuildIDEntry OBJECT-TYPE SYNTAX BladeFWBuildIDEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade Firmware Build ID table entry" INDEX { bladeFWBuildIDIndex } ::= { bladeFWBuildIDTable 1 } BladeFWBuildIDEntry ::= SEQUENCE { bladeFWBuildIDIndex INTEGER, bladeFWBuildMfg OCTET STRING, bladeFWBuildMT OCTET STRING, bladeFWBuildFWType OCTET STRING, bladeFWBuildID OCTET STRING, bladeFWBuildRev OCTET STRING } bladeFWBuildIDIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index number of one Build ID entry. For consistent results, view as a table and not as individual entries." ::= { bladeFWBuildIDEntry 1 } bladeFWBuildMfg OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The Manufacturer property of one Build ID entry. For consistent results, view as a table and not as individual entries." ::= { bladeFWBuildIDEntry 2 } bladeFWBuildMT OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The Machine Type property of one Build ID entry. For consistent results, view as a table and not as individual entries." ::= { bladeFWBuildIDEntry 3 } bladeFWBuildFWType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The Firmware Type property of one Build ID entry. For consistent results, view as a table and not as individual entries." ::= { bladeFWBuildIDEntry 4 } bladeFWBuildID OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The Build ID property of one Build ID entry. For consistent results, view as a table and not as individual entries." ::= { bladeFWBuildIDEntry 5 } bladeFWBuildRev OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The Build Revision property of one Build ID entry. For consistent results, view as a table and not as individual entries." ::= { bladeFWBuildIDEntry 6 } createBladeFWBuildIDs OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS write-only STATUS mandatory DESCRIPTION "Create one new Build ID List from current installed blades. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { bladeFWBuildIDs 2} addBladeFWBuildID OBJECT IDENTIFIER ::= { bladeFWBuildIDs 3} addBladeMfg OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Add one Build ID entry into the Build ID List. This is to set Manufacturer property." ::= { addBladeFWBuildID 1} addBladeMt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Add one Build ID entry into the Build ID List. This is to set Machine Type property." ::= {addBladeFWBuildID 2} addBladeFt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Add one Build ID entry into the Build ID List. This is to set Firmware Type property." ::= { addBladeFWBuildID 3} addBladeBuildID OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Add one Build ID entry into the Build ID List. This is to set Build ID property." ::= { addBladeFWBuildID 4} addBladeBuildRev OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Add one Build ID entry into the Build ID List. This is to set Build Revision property." ::= { addBladeFWBuildID 5} exeBladeAdding OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS write-only STATUS mandatory DESCRIPTION "Add one Build ID entry into the Build ID List. This is to perform the adding action. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { addBladeFWBuildID 6} rmBladeFWBuildID OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Remove one Build ID entry from the Build ID List. The index of the Build ID entry in the list is required. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { bladeFWBuildIDs 4} rmAllBladeFWBuildIDs OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS write-only STATUS mandatory DESCRIPTION "Remove all Build ID entries from the Build ID List. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { bladeFWBuildIDs 5} buildIDFileName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..254)) ACCESS read-write STATUS mandatory DESCRIPTION "File name of the Build ID list that will be used in import function." ::= { bladeFWBuildIDs 6 } buildIDURIName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..254)) ACCESS read-write STATUS mandatory DESCRIPTION "Contains the fully qualified remote location of the build ID list. Use buildIDFileName to specify the filename. A fully qualified remote location contains a supported protocol followed by a colon and two slashes (//), userid and password separated by a colon for login authentication, an @ sign, followed by the hostname or IP address of the server where the build ID list resides, followed by an optional port number to the hostname, and the full pathname to the file. Note that if the port number is specified, it must be separated with the hostname (or IP address) by a colon. The AMM currently supports the following protocols: TFTP, FTP, FTPS, HTTP and HTTPS. The complete format of a fully qualified remote location is: ://@/ An example of a fully qualified remote location can be: ftp://USERID:PASSW0RD@192.168.0.2:30045/tmp where the ftp protocol will be used for transferring the file in this location, username is USERID, password is PASSW0RD, host IP address is 192.168.0.2, port number is 30045, and the full pathname for the build ID list is /tmp. Some protocols do not need the username, password, and the port number, so the minimum requirement for a fully qualified location can be: :///." ::= { bladeFWBuildIDs 7 } buildIDtftpIP OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "If importing/exporting via the legacy method using a tftp server, then set the IP address or host name of the TFTP server where the firmware file resides. The address must be entered in a dotted decimal IP string (e.g. 9.37.44.2)." ::= { bladeFWBuildIDs 8 } importBladeFWBuildIDs OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS write-only STATUS mandatory DESCRIPTION "Import one Build ID List set by the buildIDFilename from a specific location set by buildIDServer." ::= { bladeFWBuildIDs 9} exportBladeFWBuildIDs OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS write-only STATUS mandatory DESCRIPTION "Export the current Build ID List from the active AMM to a specific location set by buildIDServer. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { bladeFWBuildIDs 10} statusBladeFWBuildIDs OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Gives the status message from the last import or export operation." ::= { bladeFWBuildIDs 11} -- ******************************************************************************** -- Switch Module Hardware VPD -- ******************************************************************************** smHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 6 } smHardwareVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF SmHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of the switch module hardware components. For consistent results, view as a table and not as individual entries." ::= { smHardwareVpd 1 } smHardwareVpdEntry OBJECT-TYPE SYNTAX SmHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module hardware VPD entry. For consistent results, view as a table and not as individual entries." INDEX { smHardwareVpdIndex } ::= { smHardwareVpdTable 1 } SmHardwareVpdEntry ::= SEQUENCE { smHardwareVpdIndex INTEGER, smHardwareVpdBayNumber OCTET STRING, smHardwareVpdManufacturingId OCTET STRING, smHardwareVpdFruNumber OCTET STRING, smHardwareVpdHardwareRevision INTEGER, smHardwareVpdUuid OCTET STRING, smHardwareVpdManufDate OCTET STRING, smHardwareVpdPartNumber OCTET STRING, smHardwareVpdFruSerial OCTET STRING, smHardwareVpdManufacturingIDNumber OCTET STRING, smHardwareVpdProductId OCTET STRING, smHardwareVpdSubManufacturerId OCTET STRING, smHardwareVpdClei OCTET STRING, smHardwareVpdWwnGuid OCTET STRING, smHardwareVpdWwnGuidType OCTET STRING, smHardwareVpdWidth INTEGER, smHardwareVpdHardwareRevisionString OCTET STRING } smHardwareVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module hardware VPD index. For consistent results, view as a table and not as individual entries." ::= { smHardwareVpdEntry 1 } smHardwareVpdBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module hardware VPD Bay number. For consistent results, view as a table and not as individual entries." ::= { smHardwareVpdEntry 2 } smHardwareVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries." ::= { smHardwareVpdEntry 3 } smHardwareVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module hardware VPD FRU number. For consistent results, view as a table and not as individual entries." ::= { smHardwareVpdEntry 4 } smHardwareVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { smHardwareVpdEntry 5 } smHardwareVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module hardware VPD UUID. For consistent results, view as a table and not as individual entries." ::= { smHardwareVpdEntry 8 } smHardwareVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module hardware VPD manufacture date. For consistent results, view as a table and not as individual entries." ::= { smHardwareVpdEntry 9 } smHardwareVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module hardware VPD Part Number. For consistent results, view as a table and not as individual entries." ::= { smHardwareVpdEntry 10 } smHardwareVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries." ::= { smHardwareVpdEntry 11 } smHardwareVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { smHardwareVpdEntry 12 } smHardwareVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module hardware VPD product ID. For consistent results, view as a table and not as individual entries." ::= { smHardwareVpdEntry 13 } smHardwareVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { smHardwareVpdEntry 14 } smHardwareVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries." ::= { smHardwareVpdEntry 15 } smHardwareVpdWwnGuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module hardware VPD World Wide Name or Global Unique ID. For consistent results, view as a table and not as individual entries." ::= { smHardwareVpdEntry 16 } smHardwareVpdWwnGuidType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The WWN/GUID/SAS entry is actually World Wide Name, Global Unique ID or Serial Attach SCSI ID. For consistent results, view as a table and not as individual entries." ::= { smHardwareVpdEntry 17 } smHardwareVpdWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The width of the switch module hardware. For consistent results, view as a table and not as individual entries." ::= { smHardwareVpdEntry 18 } smHardwareVpdHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used." ::= { smHardwareVpdEntry 20 } -- ******************************************************************************** -- Switch Interposer Hardware VPD -- ******************************************************************************** smInpHardwareVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF SmInpHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of the switch interposer hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only." ::= { smHardwareVpd 2 } smInpHardwareVpdEntry OBJECT-TYPE SYNTAX SmInpHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Interposer hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only." INDEX { smInpHardwareVpdIndex } ::= { smInpHardwareVpdTable 1 } SmInpHardwareVpdEntry ::= SEQUENCE { smInpHardwareVpdIndex INTEGER, smInpHardwareVpdBayNumber OCTET STRING, smInpHardwareVpdManufacturingId OCTET STRING, smInpHardwareVpdFruNumber OCTET STRING, smInpHardwareVpdHardwareRevision INTEGER, smInpHardwareVpdUuid OCTET STRING, smInpHardwareVpdManufDate OCTET STRING, smInpHardwareVpdPartNumber OCTET STRING, smInpHardwareVpdFruSerial OCTET STRING, smInpHardwareVpdManufacturingIDNumber OCTET STRING, smInpHardwareVpdProductId OCTET STRING, smInpHardwareVpdSubManufacturerId OCTET STRING, smInpHardwareVpdClei OCTET STRING, smInpHardwareVpdWwnGuid OCTET STRING, smInpHardwareVpdWwnGuidType OCTET STRING, smInpHardwareVpdWidth INTEGER, smInpHardwareVpdName OCTET STRING, smInpHardwareVpdHardwareRevisionString OCTET STRING } smInpHardwareVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch Interposer hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only." ::= { smInpHardwareVpdEntry 1 } smInpHardwareVpdBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Interposer hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only." ::= { smInpHardwareVpdEntry 2 } smInpHardwareVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Interposer hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only." ::= { smInpHardwareVpdEntry 3 } smInpHardwareVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Interposer hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only." ::= { smInpHardwareVpdEntry 4 } smInpHardwareVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch Interposer hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { smInpHardwareVpdEntry 5 } smInpHardwareVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Interposer hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only." ::= { smInpHardwareVpdEntry 8 } smInpHardwareVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Interposer hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only." ::= { smInpHardwareVpdEntry 9 } smInpHardwareVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Interposer hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only." ::= { smInpHardwareVpdEntry 10 } smInpHardwareVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Interposer module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only." ::= { smInpHardwareVpdEntry 11 } smInpHardwareVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Interposer module hardware VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only." ::= { smInpHardwareVpdEntry 12 } smInpHardwareVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Interposer module hardware VPD product ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only." ::= { smInpHardwareVpdEntry 13 } smInpHardwareVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Interposer module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only." ::= { smInpHardwareVpdEntry 14 } smInpHardwareVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Interposer module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only." ::= { smInpHardwareVpdEntry 15 } smInpHardwareVpdWwnGuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Interposer module hardware VPD World Wide Name or Global Unique ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only." ::= { smInpHardwareVpdEntry 16 } smInpHardwareVpdWwnGuidType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The Switch Interposer WWN/GUID/SAS entry is actually World Wide Name, Global Unique ID or Serial Attach SCSI ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only." ::= { smInpHardwareVpdEntry 17 } smInpHardwareVpdWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The width of the switch Interposer module hardware. For consistent results, view as a table and not as individual entries." ::= { smInpHardwareVpdEntry 18 } smInpHardwareVpdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The Switch Interposer Name. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only." ::= { smInpHardwareVpdEntry 19 } smInpHardwareVpdHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Interposer hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used." ::= { smInpHardwareVpdEntry 20 } -- ******************************************************************************** -- Switch module Information -- ******************************************************************************** smFirmwareVpd OBJECT IDENTIFIER ::= { vpdInformation 7 } -- Server blade switch module information smMainAppVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF SmMainAppVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module main application VPD information table." ::= {smFirmwareVpd 1} smMainAppVpdEntry OBJECT-TYPE SYNTAX SmMainAppVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module main application VPD table entry" INDEX { smMainAppVpdIndex } ::= { smMainAppVpdTable 1 } SmMainAppVpdEntry ::= SEQUENCE { smMainAppVpdIndex INTEGER, smMainAppVpdId INTEGER, smMainAppVpdExists INTEGER, smMainAppVpdSwitchType INTEGER, smMainApp1VpdBuildId OCTET STRING, smMainApp1VpdBuildDate OCTET STRING, smMainApp1VpdRevisionNumber OCTET STRING, smMainApp2VpdBuildId OCTET STRING, smMainApp2VpdBuildDate OCTET STRING, smMainApp2VpdRevisionNumber OCTET STRING, smMainApp3VpdBuildId OCTET STRING, smMainApp3VpdBuildDate OCTET STRING, smMainApp3VpdRevisionNumber OCTET STRING, smMainAppVpdSwitchSubType INTEGER } smMainAppVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module main application VPD entry index." ::= { smMainAppVpdEntry 1 } smMainAppVpdId OBJECT-TYPE SYNTAX INTEGER { module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The switch module numeric identifier." ::= { smMainAppVpdEntry 2 } smMainAppVpdExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module specified exists or not." ::= { smMainAppVpdEntry 3 } smMainAppVpdSwitchType OBJECT-TYPE SYNTAX INTEGER { unknown(0), ethernet(1), fibre(2), opm(3), serialCM(4), copperPassThrough(5), infiniband(6), highSpeed(20), passThrough(30), sas(40) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the type of switch module installed." ::= { smMainAppVpdEntry 4 } smMainApp1VpdBuildId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module firmware build id." ::= { smMainAppVpdEntry 5 } smMainApp1VpdBuildDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module firmware build date." ::= { smMainAppVpdEntry 6 } smMainApp1VpdRevisionNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module firmware revision number." ::= { smMainAppVpdEntry 7 } smMainApp2VpdBuildId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module firmware build id." ::= { smMainAppVpdEntry 8 } smMainApp2VpdBuildDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module firmware build date." ::= { smMainAppVpdEntry 9 } smMainApp2VpdRevisionNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module firmware revision number." ::= { smMainAppVpdEntry 10 } smMainApp3VpdBuildId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "I/O Module firmware build id." ::= { smMainAppVpdEntry 11 } smMainApp3VpdBuildDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "I/O Module firmware build date." ::= { smMainAppVpdEntry 12 } smMainApp3VpdRevisionNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "I/O Module firmware revision number." ::= { smMainAppVpdEntry 13 } smMainAppVpdSwitchSubType OBJECT-TYPE SYNTAX INTEGER { unknown(0), ethernet(1), fibre(2), infiniband(6), sas(7), raidsas(8), icpm(9) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the subtype of switch module installed." ::= { smMainAppVpdEntry 20 } smBootRomVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF SmBootRomVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module boot ROM VPD information table." ::= {smFirmwareVpd 2} smBootRomVpdEntry OBJECT-TYPE SYNTAX SmBootRomVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module boot ROM VPD table entry" INDEX { smBootRomVpdIndex } ::= { smBootRomVpdTable 1 } SmBootRomVpdEntry ::= SEQUENCE { smBootRomVpdIndex INTEGER, smBootRomVpdId INTEGER, smBootRomVpdExists INTEGER, smBootRomVpdSwitchType INTEGER, smBootRomVpdBuildId OCTET STRING, smBootRomVpdBuildDate OCTET STRING, smBootRomVpdRevisionNumber OCTET STRING, smBootRomVpdSwitchSubType INTEGER } smBootRomVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module boot ROM VPD entry index." ::= { smBootRomVpdEntry 1 } smBootRomVpdId OBJECT-TYPE SYNTAX INTEGER { module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The switch module numeric identifier." ::= { smBootRomVpdEntry 2 } smBootRomVpdExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module specified exists or not." ::= { smBootRomVpdEntry 3 } smBootRomVpdSwitchType OBJECT-TYPE SYNTAX INTEGER { unknown(0), ethernet(1), fibre(2), opm(3), serialCM(4), copperPassThrough(5), infiniband(6), highSpeed(20), passThrough(30), sas(40) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the type of switch module installed." ::= { smBootRomVpdEntry 4 } smBootRomVpdBuildId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module firmware build ID." ::= { smBootRomVpdEntry 5 } smBootRomVpdBuildDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module firmware build date." ::= { smBootRomVpdEntry 6 } smBootRomVpdRevisionNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module firmware revision number." ::= { smBootRomVpdEntry 7 } smBootRomVpdSwitchSubType OBJECT-TYPE SYNTAX INTEGER { unknown(0), ethernet(1), fibre(2), infiniband(6), sas(7), raidsas(8), icpm(9) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the subtype of switch module installed." ::= { smBootRomVpdEntry 8 } -- ******************************************************************************** -- Power Module Hardware VPD -- ******************************************************************************** pmHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 8 } pmHardwareVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF PmHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of the power module hardware components. For consistent results, view as a table and not as individual entries." ::= { pmHardwareVpd 1 } pmHardwareVpdEntry OBJECT-TYPE SYNTAX PmHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Power module hardware VPD entry. For consistent results, view as a table and not as individual entries." INDEX { pmHardwareVpdIndex } ::= { pmHardwareVpdTable 1 } PmHardwareVpdEntry ::= SEQUENCE { pmHardwareVpdIndex INTEGER, pmHardwareVpdBayNumber OCTET STRING, pmHardwareVpdManufacturingId OCTET STRING, pmHardwareVpdFruNumber OCTET STRING, pmHardwareVpdHardwareRevision INTEGER, pmHardwareVpdUuid OCTET STRING, pmHardwareVpdManufDate OCTET STRING, pmHardwareVpdPartNumber OCTET STRING, pmHardwareVpdFruSerial OCTET STRING, pmHardwareVpdManufacturingIDNumber OCTET STRING, pmHardwareVpdProductId OCTET STRING, pmHardwareVpdSubManufacturerId OCTET STRING, pmHardwareVpdClei OCTET STRING, pmHardwareVpdHardwareRevisionString OCTET STRING } pmHardwareVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Power module hardware VPD index. For consistent results, view as a table and not as individual entries." ::= { pmHardwareVpdEntry 1 } pmHardwareVpdBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power module hardware VPD Bay number. For consistent results, view as a table and not as individual entries." ::= { pmHardwareVpdEntry 2 } pmHardwareVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries." ::= { pmHardwareVpdEntry 3 } pmHardwareVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power module hardware VPD FRU number. For consistent results, view as a table and not as individual entries." ::= { pmHardwareVpdEntry 4 } pmHardwareVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Power module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { pmHardwareVpdEntry 5 } pmHardwareVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power module hardware VPD UUID. For consistent results, view as a table and not as individual entries." ::= { pmHardwareVpdEntry 8 } pmHardwareVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power module hardware VPD Manufacture Date. For consistent results, view as a table and not as individual entries." ::= { pmHardwareVpdEntry 9 } pmHardwareVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power module hardware VPD Part Number. For consistent results, view as a table and not as individual entries." ::= { pmHardwareVpdEntry 10 } pmHardwareVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries." ::= { pmHardwareVpdEntry 11 } pmHardwareVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { pmHardwareVpdEntry 12 } pmHardwareVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power module hardware VPD product ID. For consistent results, view as a table and not as individual entries." ::= { pmHardwareVpdEntry 13 } pmHardwareVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { pmHardwareVpdEntry 14 } pmHardwareVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries." ::= { pmHardwareVpdEntry 15 } pmHardwareVpdHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Power module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used." ::= { pmHardwareVpdEntry 16 } -- ******************************************************************************** -- Media Tray Hardware VPD -- ******************************************************************************** mtHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 9 } mtHardwareVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 1 hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries." ::= { mtHardwareVpd 3 } mtHardwareVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 1 hardware VPD FRU number. For consistent results, view as a table and not as individual entries." ::= { mtHardwareVpd 4 } mtHardwareVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 1 hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { mtHardwareVpd 5 } mtHardwareVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 1 hardware VPD UUID. For consistent results, view as a table and not as individual entries." ::= { mtHardwareVpd 8 } mtHardwareVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 1 hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { mtHardwareVpd 9 } mtHardwareVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 1 hardware VPD product ID. For consistent results, view as a table and not as individual entries." ::= { mtHardwareVpd 10 } mtHardwareVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 1 hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { mtHardwareVpd 11 } mtHardwareVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 1 hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries." ::= { mtHardwareVpd 12 } mtHardwareVpdCF1Capacity OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 1 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries." ::= { mtHardwareVpd 13 } mtHardwareVpdCF2Capacity OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 1 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries." ::= { mtHardwareVpd 14 } mtHardwareVpdBBU1 OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the presence of Battery Backup Unit 1. NOTE: This MIB object is for BCS only." ::= { mtHardwareVpd 15 } mtHardwareVpdBBU2 OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the presence of Battery Backup Unit 2. NOTE: This MIB object is for BCS only." ::= { mtHardwareVpd 16 } mtHardwareVpdHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 1 hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used." ::= { mtHardwareVpd 17 } mtHardwareVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 1 hardware VPD Manufacture Date." ::= { mtHardwareVpd 18 } mtHardwareVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 1 hardware VPD Part Number." ::= { mtHardwareVpd 19 } mtHardwareVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 1 hardware VPD FRU Serial." ::= { mtHardwareVpd 20 } -- ******************************************************************************** -- Bottom Media Tray Hardware VPD -- ******************************************************************************** mt2HardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 10 } mt2HardwareVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 2 hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries." ::= { mt2HardwareVpd 3 } mt2HardwareVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 2 hardware VPD FRU number. For consistent results, view as a table and not as individual entries." ::= { mt2HardwareVpd 4 } mt2HardwareVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 2 hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { mt2HardwareVpd 5 } mt2HardwareVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 2 hardware VPD UUID. For consistent results, view as a table and not as individual entries." ::= { mt2HardwareVpd 8 } mt2HardwareVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 2 hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { mt2HardwareVpd 9 } mt2HardwareVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 2 hardware VPD product ID. For consistent results, view as a table and not as individual entries." ::= { mt2HardwareVpd 10 } mt2HardwareVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 2 hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { mt2HardwareVpd 11 } mt2HardwareVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 2 hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries." ::= { mt2HardwareVpd 12 } mt2HardwareVpdCF1Capacity OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 2 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries." ::= { mt2HardwareVpd 13 } mt2HardwareVpdCF2Capacity OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 2 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries." ::= { mt2HardwareVpd 14 } mt2HardwareVpdHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 2 hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used." ::= { mt2HardwareVpd 17 } mt2HardwareVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 2 hardware VPD Manufacture Date." ::= { mt2HardwareVpd 18 } mt2HardwareVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 2 hardware VPD Part Number." ::= { mt2HardwareVpd 19 } mt2HardwareVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Media tray 2 hardware VPD FRU Serial." ::= { mt2HardwareVpd 20 } -- ******************************************************************************** -- Blower Firmware Level VPD -- ******************************************************************************** blowerFirmwareVpd OBJECT IDENTIFIER ::= { vpdInformation 12 } blowerControllerVPDTable OBJECT-TYPE SYNTAX SEQUENCE OF BlowerControllerVPDEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blower controller firmware vital product data (VPD) information. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowerFirmwareVpd 1 } blowerControllerVPDEntry OBJECT-TYPE SYNTAX BlowerControllerVPDEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blower controller firmware VPD table entry" INDEX { blowerControllerVpdIndex } ::= { blowerControllerVPDTable 1 } BlowerControllerVPDEntry ::= SEQUENCE { blowerControllerVpdIndex INTEGER, blowerControllerVpdId INTEGER, blowerControllerVpdExists INTEGER, blowerControllerVpdRevision OCTET STRING } blowerControllerVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blower controller firmware VPD table index." ::= { blowerControllerVPDEntry 1 } blowerControllerVpdId OBJECT-TYPE SYNTAX INTEGER { blower1(1), blower2(2), blower3(3), blower4(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blower ID." ::= { blowerControllerVPDEntry 2 } blowerControllerVpdExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the blower specified exists or not." ::= { blowerControllerVPDEntry 3 } blowerControllerVpdRevision OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The revision of the blower controller firmware." ::= { blowerControllerVPDEntry 7 } -- ******************************************************************************** -- Blower Hardware VPD -- ******************************************************************************** blowerHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 13 } blowerHardwareVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF BlowerHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of the blower hardware components. For consistent results, view as a table and not as individual entries. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { blowerHardwareVpd 1 } blowerHardwareVpdEntry OBJECT-TYPE SYNTAX BlowerHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blower hardware VPD entry. For consistent results, view as a table and not as individual entries." INDEX { blowerHardwareVpdIndex } ::= { blowerHardwareVpdTable 1 } BlowerHardwareVpdEntry ::= SEQUENCE { blowerHardwareVpdIndex INTEGER, blowerHardwareVpdBayNumber OCTET STRING, blowerHardwareVpdManufacturingId OCTET STRING, blowerHardwareVpdFruNumber OCTET STRING, blowerHardwareVpdHardwareRevision INTEGER, blowerHardwareVpdUuid OCTET STRING, blowerHardwareVpdManufDate OCTET STRING, blowerHardwareVpdPartNumber OCTET STRING, blowerHardwareVpdFruSerial OCTET STRING, blowerHardwareVpdManufacturingIDNumber OCTET STRING, blowerHardwareVpdProductId OCTET STRING, blowerHardwareVpdSubManufacturerId OCTET STRING, blowerHardwareVpdClei OCTET STRING, blowerHardwareVpdHardwareRevisionString OCTET STRING } blowerHardwareVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blower hardware VPD index. For consistent results, view as a table and not as individual entries." ::= { blowerHardwareVpdEntry 1 } blowerHardwareVpdBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower hardware VPD Bay number. For consistent results, view as a table and not as individual entries." ::= { blowerHardwareVpdEntry 2 } blowerHardwareVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries." ::= { blowerHardwareVpdEntry 3 } blowerHardwareVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower hardware VPD FRU number. For consistent results, view as a table and not as individual entries." ::= { blowerHardwareVpdEntry 4 } blowerHardwareVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blower hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { blowerHardwareVpdEntry 5 } blowerHardwareVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower hardware VPD UUID. For consistent results, view as a table and not as individual entries." ::= { blowerHardwareVpdEntry 8 } blowerHardwareVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries." ::= { blowerHardwareVpdEntry 9 } blowerHardwareVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower hardware VPD Part Number. For consistent results, view as a table and not as individual entries." ::= { blowerHardwareVpdEntry 10 } blowerHardwareVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries." ::= { blowerHardwareVpdEntry 11 } blowerHardwareVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { blowerHardwareVpdEntry 12 } blowerHardwareVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower hardware VPD product ID. For consistent results, view as a table and not as individual entries." ::= { blowerHardwareVpdEntry 13 } blowerHardwareVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { blowerHardwareVpdEntry 14 } blowerHardwareVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries." ::= { blowerHardwareVpdEntry 15 } blowerHardwareVpdHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Blower hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used." ::= { blowerHardwareVpdEntry 16 } -- ******************************************************************************** -- Fan Pack Firmware Level VPD -- ******************************************************************************** fanPackFirmwareVpd OBJECT IDENTIFIER ::= { vpdInformation 14 } fanPackControllerVPDTable OBJECT-TYPE SYNTAX SEQUENCE OF FanPackControllerVPDEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of fan pack controller firmware vital product data (VPD) information. NOTE: Fan packs are also referred to as Power Module Chassis Cooling Devices." ::= { fanPackFirmwareVpd 1 } fanPackControllerVPDEntry OBJECT-TYPE SYNTAX FanPackControllerVPDEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Fan Pack controller firmware VPD table entry" INDEX { fanPackControllerVpdIndex } ::= { fanPackControllerVPDTable 1 } FanPackControllerVPDEntry ::= SEQUENCE { fanPackControllerVpdIndex INTEGER, fanPackControllerVpdId INTEGER, fanPackControllerVpdExists INTEGER, fanPackControllerVpdRevision OCTET STRING } fanPackControllerVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Fan Pack controller firmware VPD table index." ::= { fanPackControllerVPDEntry 1 } fanPackControllerVpdId OBJECT-TYPE SYNTAX INTEGER { fanPack1(1), fanPack2(2), fanPack3(3), fanPack4(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric fan pack ID." ::= { fanPackControllerVPDEntry 2 } fanPackControllerVpdExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the fan pack specified exists or not." ::= { fanPackControllerVPDEntry 3 } fanPackControllerVpdRevision OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The revision of the fan pack controller firmware." ::= { fanPackControllerVPDEntry 7 } -- ******************************************************************************** -- Telco Alarm Panel Hardware VPD -- ******************************************************************************** tapHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 15 } tapHardwareVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Telco Alarm Panel hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { tapHardwareVpd 3 } tapHardwareVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Telco Alarm Panel hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { tapHardwareVpd 4 } tapHardwareVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Telco Alarm Panel hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { tapHardwareVpd 5 } tapHardwareVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Telco Alarm Panel hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { tapHardwareVpd 8 } tapHardwareVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Telco Alarm Panel hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { tapHardwareVpd 9 } tapHardwareVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Telco Alarm Panel hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { tapHardwareVpd 10 } tapHardwareVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Telco Alarm Panel hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { tapHardwareVpd 11 } tapHardwareVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Telco Alarm Panel hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { tapHardwareVpd 12 } tapHardwareVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Telco Alarm Panel hardware VPD product ID. For consistent results, view as a table and not as individual entries." ::= { tapHardwareVpd 13 } tapHardwareVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Telco Alarm Panel hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { tapHardwareVpd 14 } tapHardwareVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Telco Alarm Panel hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries." ::= { tapHardwareVpd 15 } tapHardwareVpdHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Telco Alarm Panel hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used." ::= { tapHardwareVpd 16 } -- ******************************************************************************** -- Network Clock Hardware VPD -- ******************************************************************************** ncHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 16 } ncHardwareVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF NcHardwareVpdEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Table of the Network Clock hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { ncHardwareVpd 1 } ncHardwareVpdEntry OBJECT-TYPE SYNTAX NcHardwareVpdEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Network Clock hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." INDEX { ncHardwareVpdIndex } ::= { ncHardwareVpdTable 1 } NcHardwareVpdEntry ::= SEQUENCE { ncHardwareVpdIndex INTEGER, ncHardwareVpdBayNumber OCTET STRING, ncHardwareVpdManufacturingId OCTET STRING, ncHardwareVpdFruNumber OCTET STRING, ncHardwareVpdHardwareRevision INTEGER, ncHardwareVpdUuid OCTET STRING, ncHardwareVpdManufDate OCTET STRING, ncHardwareVpdPartNumber OCTET STRING, ncHardwareVpdFruSerial OCTET STRING, ncHardwareVpdManufacturingIDNumber OCTET STRING, ncHardwareVpdProductId OCTET STRING, ncHardwareVpdSubManufacturerId OCTET STRING, ncHardwareVpdClei OCTET STRING, ncHardwareVpdHardwareRevisionString OCTET STRING } ncHardwareVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Network Clock hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { ncHardwareVpdEntry 1 } ncHardwareVpdBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Network Clock hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { ncHardwareVpdEntry 2 } ncHardwareVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Network Clock hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { ncHardwareVpdEntry 3 } ncHardwareVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Network Clock hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { ncHardwareVpdEntry 4 } ncHardwareVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Network Clock hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { ncHardwareVpdEntry 5 } ncHardwareVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Network Clock hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { ncHardwareVpdEntry 8 } ncHardwareVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Network Clock hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { ncHardwareVpdEntry 9 } ncHardwareVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Network Clock hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { ncHardwareVpdEntry 10 } ncHardwareVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Network Clock hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { ncHardwareVpdEntry 11 } ncHardwareVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Network Clock hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { ncHardwareVpdEntry 12 } ncHardwareVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Network Clock hardware VPD product ID. For consistent results, view as a table and not as individual entries." ::= { ncHardwareVpdEntry 13 } ncHardwareVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Network Clock hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { ncHardwareVpdEntry 14 } ncHardwareVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Network Clock hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries." ::= { ncHardwareVpdEntry 15 } ncHardwareVpdHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "Network Clock hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used." ::= { ncHardwareVpdEntry 16 } -- ******************************************************************************** -- Multiplexer Expansion Module Hardware VPD -- ******************************************************************************** mxHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 17 } mxHardwareVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF MxHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of the Multiplexer Expansion Module hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { mxHardwareVpd 1 } mxHardwareVpdEntry OBJECT-TYPE SYNTAX MxHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Multiplexer Expansion Module hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." INDEX { mxHardwareVpdIndex } ::= { mxHardwareVpdTable 1 } MxHardwareVpdEntry ::= SEQUENCE { mxHardwareVpdIndex INTEGER, mxHardwareVpdBayNumber OCTET STRING, mxHardwareVpdManufacturingId OCTET STRING, mxHardwareVpdFruNumber OCTET STRING, mxHardwareVpdHardwareRevision INTEGER, mxHardwareVpdUuid OCTET STRING, mxHardwareVpdManufDate OCTET STRING, mxHardwareVpdPartNumber OCTET STRING, mxHardwareVpdFruSerial OCTET STRING, mxHardwareVpdManufacturingIDNumber OCTET STRING, mxHardwareVpdProductId OCTET STRING, mxHardwareVpdSubManufacturerId OCTET STRING, mxHardwareVpdClei OCTET STRING, mxHardwareVpdHardwareRevisionString OCTET STRING } mxHardwareVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Multiplexer Expansion Module hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { mxHardwareVpdEntry 1 } mxHardwareVpdBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Multiplexer Expansion Module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { mxHardwareVpdEntry 2 } mxHardwareVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Multiplexer Expansion Module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { mxHardwareVpdEntry 3 } mxHardwareVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Multiplexer Expansion Module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { mxHardwareVpdEntry 4 } mxHardwareVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Multiplexer Expansion Module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { mxHardwareVpdEntry 5 } mxHardwareVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Multiplexer Expansion Module hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { mxHardwareVpdEntry 8 } mxHardwareVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Multiplexer Expansion Module hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { mxHardwareVpdEntry 9 } mxHardwareVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Multiplexer Expansion Module hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { mxHardwareVpdEntry 10 } mxHardwareVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Multiplexer Expansion Module hardware VPD FRU Serial Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { mxHardwareVpdEntry 11 } mxHardwareVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Multiplexer Expansion Module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { mxHardwareVpdEntry 12 } mxHardwareVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Multiplexer Expansion Module hardware VPD product ID. For consistent results, view as a table and not as individual entries." ::= { mxHardwareVpdEntry 13 } mxHardwareVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Multiplexer Expansion Module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { mxHardwareVpdEntry 14 } mxHardwareVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Multiplexer Expansion Module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries." ::= { mxHardwareVpdEntry 15 } mxHardwareVpdHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Multiplexer Expansion Module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used." ::= { mxHardwareVpdEntry 16 } -- ******************************************************************************** -- Storage Module Hardware VPD -- ******************************************************************************** stmHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 18 } stmHardwareVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF StmHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of the Storage Module hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { stmHardwareVpd 1 } stmHardwareVpdEntry OBJECT-TYPE SYNTAX StmHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Storage Module hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." INDEX { stmHardwareVpdIndex } ::= { stmHardwareVpdTable 1 } StmHardwareVpdEntry ::= SEQUENCE { stmHardwareVpdIndex INTEGER, stmHardwareVpdBayNumber OCTET STRING, stmHardwareVpdManufacturingId OCTET STRING, stmHardwareVpdFruNumber OCTET STRING, stmHardwareVpdHardwareRevision INTEGER, stmHardwareVpdUuid OCTET STRING, stmHardwareVpdManufDate OCTET STRING, stmHardwareVpdPartNumber OCTET STRING, stmHardwareVpdFruSerial OCTET STRING, stmHardwareVpdManufacturingIDNumber OCTET STRING, stmHardwareVpdProductId OCTET STRING, stmHardwareVpdSubManufacturerId OCTET STRING, stmHardwareVpdClei OCTET STRING, stmHardwareVpdHardwareRevisionString OCTET STRING } stmHardwareVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { stmHardwareVpdEntry 1 } stmHardwareVpdBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { stmHardwareVpdEntry 2 } stmHardwareVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { stmHardwareVpdEntry 3 } stmHardwareVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { stmHardwareVpdEntry 4 } stmHardwareVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this MIB object should be used." ::= { stmHardwareVpdEntry 5 } stmHardwareVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { stmHardwareVpdEntry 8 } stmHardwareVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { stmHardwareVpdEntry 9 } stmHardwareVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { stmHardwareVpdEntry 10 } stmHardwareVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module hardware VPD FRU Serial Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { stmHardwareVpdEntry 11 } stmHardwareVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { stmHardwareVpdEntry 12 } stmHardwareVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module hardware VPD product ID. For consistent results, view as a table and not as individual entries." ::= { stmHardwareVpdEntry 13 } stmHardwareVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { stmHardwareVpdEntry 14 } stmHardwareVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries." ::= { stmHardwareVpdEntry 15 } stmHardwareVpdHardwareRevisionString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be used." ::= { stmHardwareVpdEntry 16 } -- *********************************************************************** -- Storage Module Firmware VPD -- *********************************************************************** stmFirmwareVpd OBJECT IDENTIFIER ::= { vpdInformation 19 } stmFirmwareVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF StmFirmwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of the Storage Module firmware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { stmFirmwareVpd 1 } stmFirmwareVpdEntry OBJECT-TYPE SYNTAX StmFirmwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Storage Module firmware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." INDEX { stmFirmwareVpdIndex } ::= { stmFirmwareVpdTable 1 } StmFirmwareVpdEntry ::= SEQUENCE { stmFirmwareVpdIndex INTEGER, stmFirmwareVpdType OCTET STRING, stmFirmwareVpdBuildId OCTET STRING, stmFirmwareVpdReleaseDate OCTET STRING, stmFirmwareVpdRevision OCTET STRING } stmFirmwareVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module firmware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { stmFirmwareVpdEntry 1 } stmFirmwareVpdType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module firmware VPD type. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { stmFirmwareVpdEntry 2 } stmFirmwareVpdBuildId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module firmware VPD build ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { stmFirmwareVpdEntry 3 } stmFirmwareVpdReleaseDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module firmware VPD release date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { stmFirmwareVpdEntry 4 } stmFirmwareVpdRevision OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Storage Module firmware VPD revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { stmFirmwareVpdEntry 5 } -- ******************************************************************************** -- Battery Backup Unit Hardware VPD -- ******************************************************************************** bbuHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 21 } bbuHardwareVpdTable OBJECT-TYPE SYNTAX SEQUENCE OF BbuHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of the Battery Backup Unit hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { bbuHardwareVpd 1 } bbuHardwareVpdEntry OBJECT-TYPE SYNTAX BbuHardwareVpdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Battery Backup Unit hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." INDEX { bbuHardwareVpdIndex } ::= { bbuHardwareVpdTable 1 } BbuHardwareVpdEntry ::= SEQUENCE { bbuHardwareVpdIndex INTEGER, bbuHardwareVpdBayNumber OCTET STRING, bbuHardwareVpdManufacturingId OCTET STRING, bbuHardwareVpdFruNumber OCTET STRING, bbuHardwareVpdHardwareRevision INTEGER, bbuHardwareVpdUuid OCTET STRING, bbuHardwareVpdManufDate OCTET STRING, bbuHardwareVpdPartNumber OCTET STRING, bbuHardwareVpdFruSerial OCTET STRING, bbuHardwareVpdManufacturingIDNumber OCTET STRING, bbuHardwareVpdProductId OCTET STRING, bbuHardwareVpdSubManufacturerId OCTET STRING, bbuHardwareVpdClei OCTET STRING } bbuHardwareVpdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Battery Backup Unit hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { bbuHardwareVpdEntry 1 } bbuHardwareVpdBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Battery Backup Unit hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { bbuHardwareVpdEntry 2 } bbuHardwareVpdManufacturingId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Battery Backup Unit hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { bbuHardwareVpdEntry 3 } bbuHardwareVpdFruNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Battery Backup Unit hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { bbuHardwareVpdEntry 4 } bbuHardwareVpdHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Battery Backup Unit hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { bbuHardwareVpdEntry 5 } bbuHardwareVpdUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Battery Backup Unit hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { bbuHardwareVpdEntry 8 } bbuHardwareVpdManufDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Battery Backup Unit hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { bbuHardwareVpdEntry 9 } bbuHardwareVpdPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Battery Backup Unit hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { bbuHardwareVpdEntry 10 } bbuHardwareVpdFruSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Battery Backup Unit hardware VPD FRU Serial Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { bbuHardwareVpdEntry 11 } bbuHardwareVpdManufacturingIDNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Battery Backup Unit hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { bbuHardwareVpdEntry 12 } bbuHardwareVpdProductId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Battery Backup Unit hardware VPD product ID. For consistent results, view as a table and not as individual entries." ::= { bbuHardwareVpdEntry 13 } bbuHardwareVpdSubManufacturerId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Battery Backup Unit hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries." ::= { bbuHardwareVpdEntry 14 } bbuHardwareVpdClei OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Battery Backup Unit hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries." ::= { bbuHardwareVpdEntry 15 } -- ******************************************************************************** -- Reload VPD -- ******************************************************************************** reloadVpdData OBJECT IDENTIFIER ::= { vpdInformation 23 } reloadAllVpdData OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Reload all VPD data (firmware, hardware, MAC address, WWN/GUID and other Unique ID). NOTE: The value returned for the GET command is meaningless." ::= { reloadVpdData 1 } reloadFwVpdData OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Reload firmware VPD data. NOTE: The value returned for the GET command is meaningless." ::= { reloadVpdData 2 } reloadHwVpdData OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Reload hardware VPD data. NOTE: The value returned for the GET command is meaningless." ::= { reloadVpdData 3 } reloadMACAddress OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Reload blade MAC addresses. NOTE: The value returned for the GET command is meaningless." ::= { reloadVpdData 4 } reloadWwnGuidVpdData OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Reload blade and I/O module WWN/GUID and other VPD data. NOTE: The value returned for the GET command is meaningless." ::= { reloadVpdData 5 } -- ************************************************************************* -- Passive Air Filter -- ************************************************************************* airFilter OBJECT IDENTIFIER ::= { monitors 22 } passiveAirFilter OBJECT IDENTIFIER ::= { airFilter 1 } passiveAirFilterStatus OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable/Reset the passive air filter. When enabled, sending an enable or reset will reset the replace date. The reset command is only applicable in BladeCenter Telco Refresh and it will restart the Fouled Filter Detection settings. NOTE: This MIB object is only applicable for BladeCenter S, BladeCenter E Refresh, and BladeCenter Telco Refresh." ::= { passiveAirFilter 1 } passiveAirFilterMonthFreq OBJECT-TYPE SYNTAX INTEGER { oneMonth(1), threeMonths(3), sixMonths(6) } ACCESS read-write STATUS mandatory DESCRIPTION "The chassis environment. 1 month indicates high dust, 3 months indicates moderate dust and, 6 months indicates low dust. NOTE: This MIB object is for BladeCenter S and BladeCenter E Refresh only." ::= { passiveAirFilter 2 } passiveAirFilterReplaceDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..30)) ACCESS read-only STATUS mandatory DESCRIPTION "The scheduled replacement date of the air filter. NOTE: This MIB object is for BladeCenter S and BladeCenter E Refresh only." ::= { passiveAirFilter 3 } -- ************************************************************************* -- Component Information -- -- This anchor is for a new set of tables that provide information about all -- of the components in the chassis. For example, the componentInventoryTable -- provides inventory information for all components in a single table and the -- componentFirmwareTable provides firmware information for all components in -- a single table. In previously defined tables, this information was -- scattered about several tables, while this new concept provides a more -- concise presentation. -- -- ************************************************************************* componentInformation OBJECT IDENTIFIER ::= { monitors 23 } -- ************************************************************************* -- Component Inventory Information -- ************************************************************************* componentInventory OBJECT IDENTIFIER ::= { componentInformation 1 } componentInventoryTable OBJECT-TYPE SYNTAX SEQUENCE OF ComponentInventoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of component inventory information. Not all components will provide every object defined in the ComponentInventoryEntry." ::= { componentInventory 1 } componentInventoryEntry OBJECT-TYPE SYNTAX ComponentInventoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Component inventory information." INDEX { componentInventoryTopologyPath } ::= { componentInventoryTable 1 } ComponentInventoryEntry ::= SEQUENCE { componentInventoryTopologyPath OCTET STRING, componentInventoryInstance INTEGER, componentInventoryDescription OCTET STRING, componentInventoryMachineTypeModel OCTET STRING, componentInventoryMachineSerial OCTET STRING, componentInventoryAssetID OCTET STRING, componentInventoryPartNumber OCTET STRING, componentInventoryFRUNumber OCTET STRING, componentInventoryFRUSerialNumber OCTET STRING, componentInventoryManufactureID OCTET STRING, componentInventoryHardwareRevision OCTET STRING, componentInventoryManufactureDate OCTET STRING, componentInventoryUUID OCTET STRING, componentInventoryProductID OCTET STRING, componentInventorySubManufactureID OCTET STRING, componentInventoryCLEI OCTET STRING, componentInventoryAssetTag OCTET STRING, componentInventorySpeed OCTET STRING, componentInventoryIdentifier OCTET STRING, componentInventorySize INTEGER, componentInventoryMemoryType INTEGER, componentInventoryProductName OCTET STRING, componentInventoryProductVersion OCTET STRING, componentInventoryProcessorType INTEGER, componentInventoryProcessorFamily OCTET STRING, componentInventoryProcessorCores OCTET STRING, componentInventoryProcessorThreads OCTET STRING, componentInventoryProcessorL1DCache OCTET STRING, componentInventoryProcessorL1ICache OCTET STRING, componentInventoryProcessorL2Cache OCTET STRING, componentInventoryProcessorL3Cache OCTET STRING, componentInventoryProcessorVoltage OCTET STRING, componentInventoryProcessorExtClock OCTET STRING, componentInventoryProcessorDataWidth OCTET STRING, componentInventoryManufactureIDNum INTEGER } componentInventoryTopologyPath OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..100)) ACCESS read-only STATUS mandatory DESCRIPTION "The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component inventory table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries MEDIA_MODULE, 0x19 Container of one or more media devices MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card" ::= { componentInventoryEntry 1 } componentInventoryInstance OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot number or instance of a particular component. Typically, if the component plugs into the chassis, this represents the slot number. However, some components are connected to another component, and this represents the instance. For example, a blade may have several expansion cards that connect to the blade system planar, and in this case, this value identifies which expansion card instance the row represents. Note that this slot/instance value can be determined from the componentInventoryTopologyPath object, but this componentInventoryInstance object is provided as a convenience to the user." ::= { componentInventoryEntry 2 } componentInventoryDescription OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A short text string describing the particular component. For the AMM and blades, this name will be the configured name or its serial number if no user configured name is available. For all other components, this object will provide text to identify the component. If a text string is not available, a value of 'Not available' is presented. For more detail, also refer to the componentInventoryProductName object." ::= { componentInventoryEntry 3 } componentInventoryMachineTypeModel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The machine type and model number of this component. Typically, the format is XXXXYYY, where XXXX reprsents the machine type and YYY represents the model number." ::= { componentInventoryEntry 4 } componentInventoryMachineSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The machine serial number of this component." ::= { componentInventoryEntry 5 } componentInventoryAssetID OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The asset identifier of this component, typically set by some other authority than the manufacturer." ::= { componentInventoryEntry 6 } componentInventoryPartNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The part number of this component." ::= { componentInventoryEntry 7 } componentInventoryFRUNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The Field Replaceable Unit (FRU) number of this component." ::= { componentInventoryEntry 8 } componentInventoryFRUSerialNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The Field Replaceable Unit (FRU) serial number of this component." ::= { componentInventoryEntry 9 } componentInventoryManufactureID OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The text description of the manufacturer of this component." ::= { componentInventoryEntry 10 } componentInventoryHardwareRevision OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The hardware revision number of the this component." ::= { componentInventoryEntry 11 } componentInventoryManufactureDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The date when the manufacturer created this component. The format is XXYY, where XX is the week number of the year 20YY." ::= { componentInventoryEntry 12 } componentInventoryUUID OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The Universally Unique IDentifier (UUID) of this component, represented as a 16 byte hex number." ::= { componentInventoryEntry 13 } componentInventoryProductID OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The product identifier of the component assigned by the manufacturer." ::= { componentInventoryEntry 14 } componentInventorySubManufactureID OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The text sub-description of the manufacturer of this component, often used to identify a supplier for a component which has multiple suppliers." ::= { componentInventoryEntry 15 } componentInventoryCLEI OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The Common Language Equipment Identifier (CLEI) of this component." ::= { componentInventoryEntry 16 } componentInventoryAssetTag OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The asset tag of this component." ::= { componentInventoryEntry 17 } componentInventorySpeed OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A speed designation for the component, for example, processor speed." ::= { componentInventoryEntry 18 } componentInventoryIdentifier OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A unique identifier assigned by the manufacturer to the component, for example, a processor ID." ::= { componentInventoryEntry 19 } componentInventorySize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A size designation for the component, for example, a memory DIMM size or hard drive capacity." ::= { componentInventoryEntry 20 } componentInventoryMemoryType OBJECT-TYPE SYNTAX INTEGER { fpmdram(1), edo(2), edodram(3), sdram(4), multiplexedram(5), ddrsgram(6), ddrsdram(7), ddr2sdrm(8), ddr3sdram(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The architecture specification of a memory device." ::= { componentInventoryEntry 21 } componentInventoryProductName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The product name assigned by the manufacturer for this component. For more detail, also refer to the componentInventoryDescription object." ::= { componentInventoryEntry 22 } componentInventoryProductVersion OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The product version assigned by the manufacturer for this component." ::= { componentInventoryEntry 23 } componentInventoryProcessorType OBJECT-TYPE SYNTAX INTEGER { other(1), unknown(2), central(3), math(4), dsp(5), video(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The type designation for processor components." ::= { componentInventoryEntry 24 } componentInventoryProcessorFamily OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The family designation for processor components." ::= { componentInventoryEntry 25 } componentInventoryProcessorCores OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The number of cores present on a processor component." ::= { componentInventoryEntry 26 } componentInventoryProcessorThreads OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The number of threads present on a processor component." ::= { componentInventoryEntry 27 } componentInventoryProcessorL1DCache OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The level 1 data cache size of a processor component." ::= { componentInventoryEntry 28 } componentInventoryProcessorL1ICache OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The level 1 instruction cache size of a processor component." ::= { componentInventoryEntry 29 } componentInventoryProcessorL2Cache OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The level 2 cache size of a processor component." ::= { componentInventoryEntry 30 } componentInventoryProcessorL3Cache OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The level 3 cache size of a processor component." ::= { componentInventoryEntry 31 } componentInventoryProcessorVoltage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The voltage rating for a processor component." ::= { componentInventoryEntry 32 } componentInventoryProcessorExtClock OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The external clock speed of a processor component." ::= { componentInventoryEntry 33 } componentInventoryProcessorDataWidth OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The maximum data bus width capability of a processor component, expressed typically in bits." ::= { componentInventoryEntry 34 } componentInventoryManufactureIDNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The identification number assigned for the component by the manufacturer." ::= { componentInventoryEntry 35 } -- ************************************************************************* -- Component Firmware Information -- ************************************************************************* componentFirmware OBJECT IDENTIFIER ::= { componentInformation 2 } componentFirmwareTable OBJECT-TYPE SYNTAX SEQUENCE OF ComponentFirmwareEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of component firmware information. Not all components will provide every object defined in the ComponentFirmwareEntry." ::= { componentFirmware 1 } componentFirmwareEntry OBJECT-TYPE SYNTAX ComponentFirmwareEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Component firmware information." INDEX { componentFirmwareTopologyPath, componentFirmwareIndex } ::= { componentFirmwareTable 1 } ComponentFirmwareEntry ::= SEQUENCE { componentFirmwareTopologyPath OCTET STRING, componentFirmwareIndex INTEGER, componentFirmwareComponentInstance INTEGER, componentFirmwareComponentDescription OCTET STRING, componentFirmwareType OCTET STRING, componentFirmwareBuildID OCTET STRING, componentFirmwareReleaseDate OCTET STRING, componentFirmwareFilename OCTET STRING, componentFirmwareRevision OCTET STRING, componentFirmwareRevisionMajor INTEGER, componentFirmwareRevisionMinor INTEGER, componentFirmwareLevelStatus OCTET STRING, componentFirmwarePendingBuildID OCTET STRING, componentFirmwarePendingReleaseDate OCTET STRING, componentFirmwarePendingRevision OCTET STRING, componentFirmwareTypeID INTEGER } componentFirmwareTopologyPath OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..100)) ACCESS read-only STATUS mandatory DESCRIPTION "The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component firmware table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries MEDIA_MODULE, 0x19 Container of one or more media devices MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card" ::= { componentFirmwareEntry 1 } componentFirmwareIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Each component may have one or more types of firmware associated with it, and this index object identifies the particular instance." ::= { componentFirmwareEntry 2 } componentFirmwareComponentInstance OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot number or instance of a particular component. Typically, if the component plugs into the chassis, this represents the slot number. However, some components are connected to another component, and this represents the instance. For example, a blade may have several expansion cards that connect to the blade system planar, and in this case, this value identifies which expansion card instance the row represents. Note that this slot/instance value can be determined from the componentFirmwareTopologyPath object, but this componentFirmwareComponentInstance object is provided as a convenience to the user." ::= { componentFirmwareEntry 3 } componentFirmwareComponentDescription OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A short text string describing the particular component. For the AMM and blades, this name will be the configured name or its serial number if no user configured name is available. For all other components, this object will provide text to identify the component. If a text string is not available, a value of 'Not available' is presented. For more detail, also refer to the componentInventoryProductName object." ::= { componentFirmwareEntry 4 } componentFirmwareType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A text description of the type of firmware load." ::= { componentFirmwareEntry 5 } componentFirmwareBuildID OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A text description of the build identifier for this firmware load." ::= { componentFirmwareEntry 6 } componentFirmwareReleaseDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A text description of the release date for this firmware load." ::= { componentFirmwareEntry 7 } componentFirmwareFilename OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A text description of the filename of this firmware load." ::= { componentFirmwareEntry 8 } componentFirmwareRevision OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A text description of the revision level of this firmware load." ::= { componentFirmwareEntry 9 } componentFirmwareRevisionMajor OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A numeric identifier of the revision major number for this firmware load." ::= { componentFirmwareEntry 10 } componentFirmwareRevisionMinor OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A numeric identifier of the revision minor number for this firmware load." ::= { componentFirmwareEntry 11 } componentFirmwareLevelStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The level status of the firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (only one such firmware build ID)." ::= { componentFirmwareEntry 12 } componentFirmwarePendingBuildID OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A text description of the build identifier for this pending firmware load." ::= { componentFirmwareEntry 13 } componentFirmwarePendingReleaseDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A text description of the release date for this pending firmware load." ::= { componentFirmwareEntry 14 } componentFirmwarePendingRevision OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A text description of the revision level of this pending firmware load." ::= { componentFirmwareEntry 15 } componentFirmwareTypeID OBJECT-TYPE SYNTAX INTEGER { bladeFwBios(1), bladeDiagnostics(2), bladeSysMgmtProcessor(3), bladeFpga(4), bladecKVM(5), switchModuleMainAppl1(41), switchModuleMainAppl2(42), switchModuleBootROM(43), mgmtModuleMainAppl(61), mgmtModuleMainApplPendingRestart(62), fanController(81), unknown(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the type of firmware load with a numeric identifier." ::= { componentFirmwareEntry 20 } componentInventoryReady OBJECT-TYPE SYNTAX INTEGER { notReady(0), ready(1) } ACCESS read-only STATUS mandatory DESCRIPTION "When a blade management controller or the AMM is reset, the blade inventory data is refreshed in the AMM database. This includes items like IBM VPD (e.g. - serial number, UUID) and MAC address information. Applications need to know when this information has been populated on the AMM before they begin to query it using SNMP or other means. This simple flag object will return a ready or notReady indication when all blades have completed initialization and the inventory information has been provided to the AMM. Note that due to blades that may be experiencing a 'communication failure' or 'initialization failure' condition, this object may continue to show notReady. Therefore, any application that polls this object should also incorporate a timeout period. As of AMM release v5.3, a 10 minute timeout seems to be a minimum suggested polling period. A more granular, per-blade status is available via the bladeSystemStatusTable" ::= { componentInformation 3 } componentDriveTable OBJECT-TYPE SYNTAX SEQUENCE OF ComponentDriveEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of information indicating presence of a disk drive on a component. The management module does not receive any inventory VPD from the component, so only the presence of a drive can be indicated by this table." ::= { componentInformation 10 } componentDriveEntry OBJECT-TYPE SYNTAX ComponentDriveEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Component drive information." INDEX { componentDriveTopologyPath } ::= { componentDriveTable 1 } ComponentDriveEntry ::= SEQUENCE { componentDriveTopologyPath OCTET STRING, componentDriveDescription OCTET STRING } componentDriveTopologyPath OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..100)) ACCESS read-only STATUS mandatory DESCRIPTION "The unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. This component table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries MEDIA_MODULE, 0x19 Container of one or more media devices MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card" ::= { componentDriveEntry 1 } componentDriveDescription OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A short text string describing the particular drive on the component." ::= { componentDriveEntry 2 } -- ******************************************************************************** -- MM Security Settings -- ******************************************************************************** securitySettings OBJECT IDENTIFIER ::= { configureSP 3 } dataEncryption OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "If enabled, all confidential data will be encrypted. The default value is disabled. NOTE: Once the data is encrypted, the only way to reverse this process is to reset to default values." ::= { securitySettings 1 } trespassWarning OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "If enabled, a customizable trespass warning message is displayed via the Web and CLI interfaces." ::= { securitySettings 2 } trespassWarningDefault OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset the trespass warning to default value. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { securitySettings 3 } trespassMessage OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..1600)) ACCESS read-write STATUS mandatory DESCRIPTION "The value of the trespass warning message." ::= { securitySettings 4 } -- ******************************************************************************** -- MM Clock -- ******************************************************************************** spClock OBJECT IDENTIFIER ::= { configureSP 4 } spClockDateAndTimeSetting OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MM clock date and time setting. A date-time specification for the local time of day. For example to set the date and time to March 4, 2001 at 06:00:00AM, set the value to:'03/04/2001,06:00:00'. field contents range _____ ________ _____ 1 month 01..12 2 separator '/' 3 day 01..31 4 separator '/' 5 year 2000..2089 6 separator ',' 7 hour 00..23 8 separator ':' 9 minutes 00..59 10 separator ':' 11 seconds 00..59 " ::= { spClock 1 } spClockTimezoneSetting OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MM clock Greenwich Mean Time(GMT) offset and Daylight Saving Time(DST) settings. The following table lists GMT offsets and associated DST information. DST is not observed in time zones where the 'Observe DST' value does not contain 'yes' in the table. Also, note that in some cases additional information is required to determine the clock adjustment when DST is observed. The additional information is required when the GMT offset being written is +2:00 or +10:00. Examples -to set the GMT offset to +3:30, set the value to:'+3:30,no' -for Eastern Standard Time and observing DST, set the value to:'-5:00,yes' -for Egypt and observing DST, set the value to:'+2:00,yes,6' GMT Observe Additional Offset DST? DST value ______ _______ __________ +0:00 yes|no +1:00 yes|no +2:00 yes|no When 'Observe DST?' value is 'yes': 5 (for E.Europe) 4 (for GTB) 6 (for Egypt) 7 (for FLE) +3:00 yes|no +3:30 yes|no +4:00 no +4:30 no +5:00 yes|no +5:30 no +6:00 no +7:00 no +8:00 yes|no +9:00 yes|no +9:30 yes|no When 'Observe DST?' value is 'yes': 10 (for South AUS) 9 (for other locations) +10:00 yes|no When 'Observe DST?' value is 'yes': 9 (for AUS Eastern) 10 (for TAS,ACT,NSW,VIC) 4 (for Vladivostok) +11:00 no +12:00 yes|no -12:00 no -11:00 no -10:00 no -9:00 yes|no When 'Observe DST?' value is 'yes': 12 (for USA and Canada) 1 (for other locations) -8:00 yes|no When 'Observe DST?' value is 'yes': 12 (for USA and Canada) 1 (for other locations) -7:00 yes|no When 'Observe DST?' value is 'yes': 12 (for USA and Canada) 1 (for other locations) -6:00 yes|no When 'Observe DST?' value is 'yes': 12 (for USA and Canada) 1 (for other locations) -5:00 yes|no When 'Observe DST?' value is 'yes': 12 (for USA and Canada) 1 (for other locations) -4:00 yes|no When 'Observe DST' value is 'yes': 12 (for Canada) 1 (for other locations) -3:30 yes|no -3:00 yes|no -2:00 yes|no -1:00 yes|no " ::= { spClock 2 } -- ******************************************************************************** -- MM identification -- ******************************************************************************** spIdentification OBJECT IDENTIFIER ::= { configureSP 5 } spTxtId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) ACCESS read-write STATUS mandatory DESCRIPTION "MM text ID. NOTE: Do not put any 'space characters' at end of the ID." ::= { spIdentification 1 } -- ******************************************************************************** -- Network Configuration -- ******************************************************************************** networkConfiguration OBJECT IDENTIFIER ::= { configureSP 9 } -- ******************************************************************************** -- Network Interfaces -- ******************************************************************************** networkInterfaces OBJECT IDENTIFIER ::= { networkConfiguration 1 } -- ******************************************************************************** -- Ethernet Interface 1 -- ******************************************************************************** extEthernetInterface OBJECT IDENTIFIER ::= { networkInterfaces 1 } extEthernetInterfaceType OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "The type of interface. Indicates 'Ethernet-1'." ::= { extEthernetInterface 1 } extEthernetInterfaceHostName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Contains the 64 byte null terminated DNS host name for this interface." ::= { extEthernetInterface 3 } extEthernetInterfaceIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Contains the IP address for the ethernet interface." ::= { extEthernetInterface 4 } extEthernetInterfaceDataRate OBJECT-TYPE SYNTAX INTEGER { enet10Megabit(3), enet100Megabit(4), autoSpeed(5), enet1GigabitAuto(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, 1G Auto or Auto. Note that not all AMM hardware supports the 1G Auto speed. If it does not and a SET of this value is attempted, it will be rejected with a badValue return code. When a user selects the 1G Auto setting, the duplex setting will be forced to fullDuplex." ::= { extEthernetInterface 5 } extEthernetInterfaceDuplexSetting OBJECT-TYPE SYNTAX INTEGER { fullDuplex(1), halfDuplex(2), autoDuplex(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. When a user selects the 1G Auto speed setting, the duplex setting will be forced to fullDuplex." ::= { extEthernetInterface 6 } extEthernetInterfaceLAA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(17)) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This MM subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number. NOTE: Although the locally administered MAC address can be assigned the same value for the primary and backup AMM, it is not recommended." ::= { extEthernetInterface 7 } extEthernetInterfaceDhcpEnabled OBJECT-TYPE SYNTAX INTEGER { dhcpDisabled(0), dhcpEnabled(1), tryDhcpThenTryStatic(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable or enable DHCP on this interface." ::= { extEthernetInterface 8 } extEthernetInterfaceGatewayIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Contains the IP address of the gateway/router for the ethernet interface." ::= { extEthernetInterface 9 } extEthernetInterfaceBIA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(17)) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the burned-in MAC (BIA) address." ::= { extEthernetInterface 10 } extEthernetInterfaceMTU OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Contains the Maximum Transmission Unit(MTU) for the ethernet interface" ::= { extEthernetInterface 13 } extEthernetInterfaceSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Contains the subnet mask for the ethernet interface" ::= { extEthernetInterface 14 } -- ******************************************************************************** -- DHCP Server Assigned Settings for ethernet interface 1 -- ******************************************************************************** dhcpEthernetInterface OBJECT IDENTIFIER ::= { extEthernetInterface 16 } dhcpHostName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Contains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server." ::= { dhcpEthernetInterface 1 } dhcpIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Contains the IP address for the ethernet interface, assigned by the DHCP server." ::= { dhcpEthernetInterface 2 } dhcpGatewayIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Contains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server." ::= { dhcpEthernetInterface 3 } dhcpSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Contains the Subnet Mask for the ethernet interface, assigned by the DHCP server." ::= { dhcpEthernetInterface 4 } dhcpDomainName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Contains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server." ::= { dhcpEthernetInterface 5 } dhcpDHCPServer OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Contains the DHCP server IP address used to acquire the DHCP settings." ::= { dhcpEthernetInterface 6 } dhcpPrimaryDNSServer OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Contains the Primary DNS server, assigned by the DHCP server." ::= { dhcpEthernetInterface 7 } dhcpSecondaryDNSServer OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Contains the Secondary DNS server, assigned by the DHCP server." ::= { dhcpEthernetInterface 8 } dhcpTertiaryDNSServer OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Contains the tertiary DNS server, assigned by the DHCP server." ::= { dhcpEthernetInterface 9 } -- ******************************************************************************** -- PPP Interface 1 -- ******************************************************************************** intEthernetInterface OBJECT IDENTIFIER ::= { networkInterfaces 2 } intEthernetInterfaceType OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) ACCESS read-only STATUS deprecated DESCRIPTION "The type of interface. Indicates 'PPP-1'. NOTE: This Mib object is deprecated and no longer supported." ::= { intEthernetInterface 1 } intEthernetInterfaceEnabled OBJECT-TYPE SYNTAX INTEGER { interfaceDisabled(0), interfaceEnabled(1) } ACCESS read-write STATUS deprecated DESCRIPTION "Disable or enable the internal ethernet interface. NOTE: To alter any of the configuration settings for the ethernet interface, the following procedure should be used: (1) This object should be set to 'interfaceDisabled' (2) Make the modifications to other settings (3) This object should be set to 'interfaceEnabled' (4) Restart the management module Also note that when attempting to enable this interface, the remote IP address is verified to be nonzero. If this verification fails, an error response will be returned and the internal ethernet interface will be left disabled. NOTE: This Mib object is deprecated and no longer supported." ::= { intEthernetInterface 2 } intEthernetInterfaceLocalIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS deprecated DESCRIPTION "Contains the IP address for the MM side of the internal ethernet link. NOTE: This Mib object is deprecated and no longer supported." ::= { intEthernetInterface 4 } intEthernetInterfaceDataRate OBJECT-TYPE SYNTAX INTEGER { enet10Megabit(3), enet100Megabit(4), autoSpeed(5) } ACCESS read-only STATUS deprecated DESCRIPTION "Specifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, or Auto. NOTE: This Mib object is deprecated and no longer supported." ::= { intEthernetInterface 5 } intEthernetInterfaceDuplexSetting OBJECT-TYPE SYNTAX INTEGER { fullDuplex(1), halfDuplex(2), autoDuplex(3) } ACCESS read-only STATUS deprecated DESCRIPTION "Specifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. NOTE: This Mib object is deprecated and no longer supported." ::= { intEthernetInterface 6 } intEthernetInterfaceLAA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(17)) ACCESS read-write STATUS deprecated DESCRIPTION "Specifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This MM subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number. NOTE: This Mib object is deprecated and no longer supported." ::= { intEthernetInterface 7 } intEthernetInterfaceGatewayIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS deprecated DESCRIPTION "Contains the IP address of the gateway/router for the ethernet interface. NOTE: This Mib object is deprecated and no longer supported." ::= { intEthernetInterface 9 } intEthernetInterfaceBIA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(17)) ACCESS read-only STATUS deprecated DESCRIPTION "Specifies the burned-in MAC (BIA) address. NOTE: This Mib object is deprecated and no longer supported." ::= { intEthernetInterface 10 } intEthernetInterfaceMTU OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Contains the Maximum Transmission Unit (MTU) for the ethernet interface NOTE: This Mib object is deprecated and no longer supported." ::= { intEthernetInterface 13 } intEthernetInterfaceSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS deprecated DESCRIPTION "Contains the subnet mask for the ethernet interface. NOTE: This Mib object is deprecated and no longer supported." ::= { intEthernetInterface 14 } -- ******************************************************************************** -- Standby Ethernet Interface 1 -- ******************************************************************************** standbyExtEthernetInterface OBJECT IDENTIFIER ::= { networkInterfaces 3 } standbyExtEthernetInterfaceType OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "The type of interface. Indicates 'Ethernet-1'. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { standbyExtEthernetInterface 1 } standbyExtEthernetInterfaceHostName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Contains the 64 byte null terminated DNS host name for this interface. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { standbyExtEthernetInterface 3 } standbyExtEthernetInterfaceIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Contains the IP address for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { standbyExtEthernetInterface 4 } standbyExtEthernetInterfaceDataRate OBJECT-TYPE SYNTAX INTEGER { enet10Megabit(3), enet100Megabit(4), autoSpeed(5), enet1GigabitAuto(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, 1G Auto or Auto. NOTE: This MIB object is only applicable to systems with a standby MM. Note that not all AMM hardware supports the 1G Auto speed. If it does not and a SET of this value is attempted, it will be rejected with a badValue return code. When a user selects the 1G Auto setting, the duplex setting will be forced to fullDuplex." ::= { standbyExtEthernetInterface 5 } standbyExtEthernetInterfaceDuplexSetting OBJECT-TYPE SYNTAX INTEGER { fullDuplex(1), halfDuplex(2), autoDuplex(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. NOTE: This MIB object is only applicable to systems with a standby MM. When a user selects the 1G Auto speed setting, the duplex setting will be forced to fullDuplex." ::= { standbyExtEthernetInterface 6 } standbyExtEthernetInterfaceLAA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(17)) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This MM subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number. NOTE: This MIB object is only applicable to systems with a standby MM. NOTE: Although the locally administered MAC address can be assigned the same value for the primary and backup AMM, it is not recommended." ::= { standbyExtEthernetInterface 7 } standbyExtEthernetInterfaceDhcpEnabled OBJECT-TYPE SYNTAX INTEGER { dhcpDisabled(0), dhcpEnabled(1), tryDhcpThenTryStatic(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable or enable DHCP on this interface. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { standbyExtEthernetInterface 8 } standbyExtEthernetInterfaceGatewayIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Contains the IP address of the gateway/router for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { standbyExtEthernetInterface 9 } standbyExtEthernetInterfaceBIA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(17)) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the burned-in MAC (BIA) address. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { standbyExtEthernetInterface 10 } standbyExtEthernetInterfaceMTU OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Contains the Maximum Transmission Unit (MTU) for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { standbyExtEthernetInterface 13 } standbyExtEthernetInterfaceSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Contains the subnet mask for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { standbyExtEthernetInterface 14 } advancedFailover OBJECT-TYPE SYNTAX INTEGER{ off(0), ipnoswap(1), ipswap(2) } ACCESS read-write STATUS mandatory DESCRIPTION "User can enable advanced failover. off : no standby network interface ipswap: Standby network interface, swap IPs during failover ipnoswap: Standby network interface, no swap IPs during failover. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { standbyExtEthernetInterface 15 } -- ******************************************************************************** -- DHCP Server Assigned Settings for standby ethernet interface 1 -- ******************************************************************************** standbyDhcpEthernetInterface OBJECT IDENTIFIER ::= { standbyExtEthernetInterface 16 } standbyDhcpHostName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Contains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { standbyDhcpEthernetInterface 1 } standbyDhcpIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Contains the IP address for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { standbyDhcpEthernetInterface 2 } standbyDhcpGatewayIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Contains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { standbyDhcpEthernetInterface 3 } standbyDhcpSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Contains the Subnet Mask for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { standbyDhcpEthernetInterface 4 } standbyDhcpDomainName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Contains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { standbyDhcpEthernetInterface 5 } standbyDhcpDHCPServer OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Contains the DHCP server IP address used to acquire the DHCP settings. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { standbyDhcpEthernetInterface 6 } standbyDhcpPrimaryDNSServer OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Contains the Primary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { standbyDhcpEthernetInterface 7 } standbyDhcpSecondaryDNSServer OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Contains the Secondary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { standbyDhcpEthernetInterface 8 } standbyDhcpTertiaryDNSServer OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Contains the tertiary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { standbyDhcpEthernetInterface 9 } -- ******************************************************************************** -- Ethernet Interface IPv6 -- ******************************************************************************** extEthernetInterfaceIPv6 OBJECT IDENTIFIER ::= { networkInterfaces 4 } extEthernetInterfaceIPv6Type OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "The type of interface. Indicates 'Ethernet-1'." ::= { extEthernetInterfaceIPv6 1 } extEthernetInterfaceIPv6Enabled OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The current IPv6 enabled or disabled state of this AMM. NOTE: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this AMM, when you update the firmware to a level which does not support IPv6, all IPv6 connectivity will be lost, and services/interfaces for which an IPv6 address was configured may not function properly. You will be required to reconfigure these services/interfaces." ::= { extEthernetInterfaceIPv6 2 } extEthernetInterfaceIPv6Config OBJECT IDENTIFIER ::= { extEthernetInterfaceIPv6 5 } extEthernetInterfaceIPv6LocalAddress OBJECT IDENTIFIER ::= { extEthernetInterfaceIPv6Config 1 } extEthernetInterfaceIPv6LinkLocalAddress OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-only STATUS mandatory DESCRIPTION "The IPv6 link local IP address for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'." ::= { extEthernetInterfaceIPv6LocalAddress 1 } extEthernetInterfaceIPv6StaticIPConfig OBJECT IDENTIFIER ::= { extEthernetInterfaceIPv6Config 2 } extEthernetInterfaceIPv6StaticIPConfigEnabled OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The IPv6 static IP address enabled or disabled state for the ethernet interface." ::= { extEthernetInterfaceIPv6StaticIPConfig 1 } extEthernetInterfaceIPv6StaticIPAddress OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-write STATUS mandatory DESCRIPTION "The IPv6 static IP address for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'." ::= { extEthernetInterfaceIPv6StaticIPConfig 2 } extEthernetInterfaceIPv6StaticIPAddressPrefixLen OBJECT-TYPE SYNTAX INTEGER (1..128) ACCESS read-write STATUS mandatory DESCRIPTION "The IPv6 static IP address prefix length for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value 0." ::= { extEthernetInterfaceIPv6StaticIPConfig 3 } extEthernetInterfaceIPv6StaticIPDefaultRoute OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-write STATUS mandatory DESCRIPTION "The IPv6 static IP address default route for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'." ::= { extEthernetInterfaceIPv6StaticIPConfig 4 } extEthernetInterfaceIPv6AutoIPConfig OBJECT IDENTIFIER ::= { extEthernetInterfaceIPv6Config 3 } extEthernetInterfaceIPv6AutoIPConfigEnabled OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The IPv6 automatic IP configuration enabled or disabled state for the ethernet interface. NOTE: extEthernetInterfaceIPv6AutoIPConfigEnabled is the logical OR of extEthernetInterfaceDHCPv6Enabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled settings. NOTE: Enabling/Disabling extEthernetInterfaceIPv6AutoIPConfigEnabled will cause both extEthernetInterfaceDHCPv6Enabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled to be enabled/disabled. NOTE: extEthernetInterfaceIPv6StaticIPConfigEnabled and extEthernetInterfaceIPv6AutoIPConfigEnabled cannot be disabled at the same time." ::= { extEthernetInterfaceIPv6AutoIPConfig 1 } extEthernetInterfaceDHCPv6Config OBJECT IDENTIFIER ::= { extEthernetInterfaceIPv6AutoIPConfig 2 } extEthernetInterfaceDHCPv6Enabled OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The DHCPv6 enabled or disabled state for the ethernet interface. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled is currently disabled, Disabling extEthernetInterfaceDHCPv6Enabled will cause extEthernetInterfaceIPv6AutoIPConfigEnabled to be disabled. NOTE: If extEthernetInterfaceIPv6StaticIPConfigEnabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled are currently disabled, Disabling extEthernetInterfaceDHCPv6Enabled will not be allowed." ::= { extEthernetInterfaceDHCPv6Config 1 } extEthernetInterfaceDHCPv6IPAddress OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-only STATUS mandatory DESCRIPTION "The IPv6 address for the ethernet interface, assigned by DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'." ::= { extEthernetInterfaceDHCPv6Config 2 } extEthernetInterfaceDHCPv6DomainName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "The 64 byte Domain Name for the ethernet interface, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '(Not available)'." ::= { extEthernetInterfaceDHCPv6Config 4 } extEthernetInterfaceDHCPv6PrimaryDNSServer OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-only STATUS mandatory DESCRIPTION "The primary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'." ::= { extEthernetInterfaceDHCPv6Config 5 } extEthernetInterfaceDHCPv6SecondaryDNSServer OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-only STATUS mandatory DESCRIPTION "The secondary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'." ::= { extEthernetInterfaceDHCPv6Config 6 } extEthernetInterfaceDHCPv6TertiaryDNSServer OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-only STATUS mandatory DESCRIPTION "The tertiary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'." ::= { extEthernetInterfaceDHCPv6Config 7 } extEthernetInterfaceDHCPv6Server OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-only STATUS mandatory DESCRIPTION "The DHCPv6 server IPv6 address used to acquire the DHCP settings. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'." ::= { extEthernetInterfaceDHCPv6Config 8 } extEthernetInterfaceIPv6StatelessAutoConfig OBJECT IDENTIFIER ::= { extEthernetInterfaceIPv6AutoIPConfig 3 } extEthernetInterfaceIPv6StatelessAutoConfigEnabled OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The IPv6 stateless auto-configuration enabled or disabled state for the ethernet interface. NOTE: If extEthernetfInterfaceDHCPv6Enabled is currently disabled, Disabling extEthernetInterfaceIPv6StatelessAutoConfigEnabled will cause extEthernetInterfaceIPv6AutoIPConfigEnabled to be disabled." ::= { extEthernetInterfaceIPv6StatelessAutoConfig 1 } extEthernetInterfaceStatelessAutoConfigAddressesTable OBJECT-TYPE SYNTAX SEQUENCE OF ExtEthernetInterfaceStatelessAutoConfigAddressesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of stateless Auto-Config addresses entries" ::= { extEthernetInterfaceIPv6StatelessAutoConfig 2 } extEthernetInterfaceStatelessAutoConfigAddressesEntry OBJECT-TYPE SYNTAX ExtEthernetInterfaceStatelessAutoConfigAddressesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Stateless Auto-Config address entries" INDEX { extEthernetInterfaceStatelessAutoConfigAddressesIndex } ::= { extEthernetInterfaceStatelessAutoConfigAddressesTable 1 } ExtEthernetInterfaceStatelessAutoConfigAddressesEntry ::= SEQUENCE { extEthernetInterfaceStatelessAutoConfigAddressesIndex INTEGER, extEthernetInterfaceStatelessAutoConfigAddresses InetAddressIPv6, extEthernetInterfaceStatelessAutoConfigAddressesPrefixLen INTEGER } extEthernetInterfaceStatelessAutoConfigAddressesIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index for stateless Auto-Config addresses. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing." ::= { extEthernetInterfaceStatelessAutoConfigAddressesEntry 1 } extEthernetInterfaceStatelessAutoConfigAddresses OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-only STATUS mandatory DESCRIPTION "The stateless Auto-Configuration IPv6 address. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing." ::= { extEthernetInterfaceStatelessAutoConfigAddressesEntry 2 } extEthernetInterfaceStatelessAutoConfigAddressesPrefixLen OBJECT-TYPE SYNTAX INTEGER (1..128) ACCESS read-only STATUS mandatory DESCRIPTION "The stateless Auto-Configration address prefix length. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this object will show nothing." ::= { extEthernetInterfaceStatelessAutoConfigAddressesEntry 3 } standbyExtEthernetInterfaceIPv6 OBJECT IDENTIFIER ::= { networkInterfaces 5 } standbyEthernetInterfaceIPv6LocalAddress OBJECT IDENTIFIER ::= { standbyExtEthernetInterfaceIPv6 1 } standbyEthernetInterfaceIPv6LinkLocalAddress OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-only STATUS mandatory DESCRIPTION "The IPv6 link local IP address for the standby AMM." ::= { standbyEthernetInterfaceIPv6LocalAddress 1 } standbyEthernetInterfaceIPv6StaticIPConfig OBJECT IDENTIFIER ::= { standbyExtEthernetInterfaceIPv6 2 } standbyEthernetInterfaceIPv6StaticIPConfigEnabled OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The IPv6 static IP address state for the AMM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPConfigEnabled object." ::= { standbyEthernetInterfaceIPv6StaticIPConfig 1 } standbyEthernetInterfaceIPv6StaticIPAddress OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-write STATUS mandatory DESCRIPTION "The IPv6 static IP address for the standby AMM NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'." ::= { standbyEthernetInterfaceIPv6StaticIPConfig 2 } standbyEthernetInterfaceIPv6StaticIPAddressPrefixLen OBJECT-TYPE SYNTAX INTEGER (1..128) ACCESS read-only STATUS mandatory DESCRIPTION "The IPv6 static IP address prefix length for the standyby AMM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPAddressPrefixLen object." ::= { standbyEthernetInterfaceIPv6StaticIPConfig 3 } standbyEthernetInterfaceIPv6StaticIPDefaultRoute OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-only STATUS mandatory DESCRIPTION "The IPv6 static IP address default route for the standby AMM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPDefaultRoute object." ::= { standbyEthernetInterfaceIPv6StaticIPConfig 4 } standbyEthernetInterfaceDHCPv6Config OBJECT IDENTIFIER ::= { standbyExtEthernetInterfaceIPv6 3 } standbyEthernetInterfaceDHCPv6Enabled OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The DHCPv6 enabled or disabled state for the standby AMM. NOTE: This field may be altered through the extEthernetInterfaceDHCPv6Enabled object." ::= { standbyEthernetInterfaceDHCPv6Config 1 } standbyEthernetInterfaceDHCPv6IPAddress OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-only STATUS mandatory DESCRIPTION "The IPv6 address for the standby AMM assigned by DHCPv6 server." ::= { standbyEthernetInterfaceDHCPv6Config 2 } standbyEthernetInterfaceDHCPv6DomainName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "The 64 byte Domain Name for the standby AMM assigned by the DHCPv6 server." ::= { standbyEthernetInterfaceDHCPv6Config 4 } standbyEthernetInterfaceStatelessAutoConfigAddressesTable OBJECT-TYPE SYNTAX SEQUENCE OF StandbyEthernetInterfaceStatelessAutoConfigAddressesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of stateless Auto-Config addresses entries. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled, this table will show nothing." ::= { standbyExtEthernetInterfaceIPv6 4 } standbyEthernetInterfaceStatelessAutoConfigAddressesEntry OBJECT-TYPE SYNTAX StandbyEthernetInterfaceStatelessAutoConfigAddressesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Stateless Auto-Config address entries" INDEX { standbyEthernetInterfaceStatelessAutoConfigAddressesIndex } ::= { standbyEthernetInterfaceStatelessAutoConfigAddressesTable 1 } StandbyEthernetInterfaceStatelessAutoConfigAddressesEntry ::= SEQUENCE { standbyEthernetInterfaceStatelessAutoConfigAddressesIndex INTEGER, standbyEthernetInterfaceStatelessAutoConfigAddresses InetAddressIPv6, standbyEthernetInterfaceStatelessAutoConfigAddressesPrefixLen INTEGER } standbyEthernetInterfaceStatelessAutoConfigAddressesIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index for stateless Auto-Config addresses." ::= { standbyEthernetInterfaceStatelessAutoConfigAddressesEntry 1 } standbyEthernetInterfaceStatelessAutoConfigAddresses OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-only STATUS mandatory DESCRIPTION "The stateless Auto-Configuration IPv6 address." ::= { standbyEthernetInterfaceStatelessAutoConfigAddressesEntry 2 } standbyEthernetInterfaceStatelessAutoConfigAddressesPrefixLen OBJECT-TYPE SYNTAX INTEGER (1..128) ACCESS read-only STATUS mandatory DESCRIPTION "The stateless Auto-Configration address prefix length." ::= { standbyEthernetInterfaceStatelessAutoConfigAddressesEntry 3 } ddnsStatus OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Dynamic DNS provides the capability for a networked device to notify a domain name server to change, in real time, the active DNS configuration of its configured hostnames, addresses or other information stored in DNS. With Dynamic DNS, host computers gain the capability to notify their respective DNS server of the IP address they have received from a DHCP server or through self-configuration." ::= { networkInterfaces 10 } hostName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Contains the DNS host name for this system. This object provides the exact same function as extEthernetInterfaceHostName" ::= { networkInterfaces 11 } standbyHostName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Contains the DNS host name for the standby. This object provides the exact same function as standbyExtEthernetInterfaceHostName and is only applicable to systems with a standby MM." ::= { networkInterfaces 12 } domainName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The user assigned DNS domain name." ::= { networkInterfaces 13 } standbyDomainName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The user assigned DNS domain name of the standby. This is only applicable to systems with a standby MM." ::= { networkInterfaces 14 } vlanConfigure OBJECT IDENTIFIER ::= { networkInterfaces 20 } vlanGlobalState OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This object disables or enables the VLAN feature. The configuration objects for the VLAN are in the table, vlanTable. The default setting for this object is disable(0). IMPORTANT NOTE: Any change to this object will revert back to its previous value if the change is not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout." ::= { vlanConfigure 1 } vlanCommitTimeout OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "This object is the number of minutes from the last VLAN-related object change until any non-committed changes will revert back to their previous settings. This means if a user makes a change that disrupts TCP/IP access to the CMM, the change will revert back to its previous setting after the number of minutes in this object. This allows the user to access the CMM again if access is lost through an unintended VLAN setting. Once the changes are committed using the object, vlanCommitState, setting it to executeCommit(3), the changes will be saved in non-volatile memory. The amount of time before uncommitted changes revert back to their previous settings starts from the last change made to any VLAN-related object. If no other change is made, the user has this number of minutes (the number in this object) to commit the changes with vlanCommitState before the changes will revert back. The default setting for this object is 2 minutes. IMPORTANT NOTE: Any change to this object will revert back to its previous value if the change is not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout." ::= { vlanConfigure 2 } vlanCommitState OBJECT-TYPE SYNTAX INTEGER { noChangesPending(1), commitNeeded(2), executeCommit(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object gives the status of whether there are VLAN-related changes pending that need to be committed, and allows a user to commit (save) any VLAN changes. If changes are pending, reading this object will give a value of commitNeeded(2). If no changes are pending, this object will have the value of noChangesPending(1). To save any VLAN-related changes so they do not revert back to previous settings, set this object to executeCommit(3) whenever this object has a value of commitNeeded(2)." ::= { vlanConfigure 3 } vlanTable OBJECT-TYPE SYNTAX SEQUENCE OF VlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the VLAN configuration objects. The default entry has an vlanEntryIndex equal to 1. The objects for this default entry are configurable. An additional VLAN entry may be added by setting the object, vlanEntryStatus, at vlanEntryIndex=2 to the value of createRequest(2) and also setting the object, vlanEntryVlanId, at vlanEntryIndex=2 to a valid, unique value. IMPORTANT NOTE: Any changes to the object of this table will revert back to their previous settings if the changes are not committed by setting the object vlanCommitState to executeCommit(3) within the number of minutes indicated in the object vlanCommitTimeout." ::= { vlanConfigure 20 } vlanEntry OBJECT-TYPE SYNTAX VlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "VLAN entries." INDEX { vlanEntryIndex } ::= { vlanTable 1 } VlanEntry ::= SEQUENCE { vlanEntryIndex INTEGER, vlanEntryVlanId INTEGER, vlanEntryName OCTET STRING, vlanEntryStatus EntryStatus, vlanEntryState INTEGER, vlanEntrySOLAccess INTEGER, vlanEntrycKVMAccess INTEGER, vlanEntryTagging INTEGER, vlanEntryIOModuleAccess INTEGER, vlanEntryVlanDefault INTEGER, vlanEntryIPv4StaticAddress IpAddress, vlanEntryIPv4StaticGateway IpAddress, vlanEntryIPv4StaticMask IpAddress, vlanEntryIPv4SubnetRoute1 IpAddress, vlanEntryIPv4SubnetRouteMask1 IpAddress, vlanEntryIPv4SubnetRoute2 IpAddress, vlanEntryIPv4SubnetRouteMask2 IpAddress, vlanEntryIPv4SubnetRoute3 IpAddress, vlanEntryIPv4SubnetRouteMask3 IpAddress } vlanEntryIndex OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Index for VLAN entry. If vlanEntryIndex is equal to 1, it is the Default VLAN entry and cannot be deleted." ::= { vlanEntry 1 } vlanEntryVlanId OBJECT-TYPE SYNTAX INTEGER (1..4094) ACCESS read-write STATUS mandatory DESCRIPTION "Valid VLAN ID. Allowed values are 1..4094. If the entry is not valid, this object will have the value of 0. If this entry has the vlanEntryIndex value of 1 (default VLAN entry), then setting this object will take effect immediately. For other entries, when this object is set, this entry must have the object, vlanEntryState set to enable(1) or restart(2) for this change to take effect." ::= { vlanEntry 2 } vlanEntryName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "This object allows the user to configure a text string name for this VLAN entry. This entry name is only used as a label for this entry." ::= { vlanEntry 3 } vlanEntryStatus OBJECT-TYPE SYNTAX EntryStatus ACCESS read-write STATUS mandatory DESCRIPTION "This object manages the creation and deletion of this entry. The steps recommended to add a new VLAN entry are: 1. Create a new entry in this table vlanEntryStatus = createRequest 2. Set vlanEntryVlanId as required. Then the entry will be valid. valid(1) - Indicates that this entry is available for use. createRequest(2) - A new entry will be created in this table and will transition to the vlanEntryStatus value of underCreation(3). underCreation(3) - Indicates that this entry exists in the agent but is unavailable for use. After completing the create operation, the agent will set this object to the value underCreation(3). invalid(4) - Deletes this entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) cannot be deleted." ::= { vlanEntry 4 } vlanEntryState OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1), restart(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates whether this VLAN entry is enabled or disabled and allows the user to disable, enable or restart this entry except for the exceptions noted below. The entry with a vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to enable(1) and cannot be set to any other value. Other table entries do not have this restriction. Some other objects in this table may not take effect after a change until either this object is: set to enable(1) if this object currently has the value of disable(0), or set to restart(2) if this object currently has the value of enable(1). The other objects in this table that require this object be set to enable(1) or restart(2) after a change are noted in the description for those objects." ::= { vlanEntry 5 } vlanEntrySOLAccess OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This object allows the user to set whether the VLAN for this entry will have access to the Serial Over LAN (SOL) interface. Only one VLAN entry may have this object set to enable(1). By default, the entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to enable(1). To set this object to enable(1) on another entry, this object must first be set to disable(0) on any entry that has this object set to enable(1)." ::= { vlanEntry 6 } vlanEntrycKVMAccess OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This object allows the user to set whether the VLAN for this entry will have access to the installed cards for concurrent keyboard, video, and mouse (cKVM). Only one VLAN entry may have this object set to enable(1). By default, the entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to enable(1). To set this object to enable(1) on another entry, this object must first be set to disable(0) on any entry that has this object set to enable(1)." ::= { vlanEntry 7 } vlanEntryTagging OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This object allows the user to set whether VLAN tagging is enabled for this VLAN entry. This object is only configurable for the entry with the vlanEntryIndex value of 1. By default, the entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to disable(0), all other entries will have this object set to enable(1)." ::= { vlanEntry 8 } vlanEntryIOModuleAccess OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This read-only object indicates whether the VLAN for this entry will have access to the IO Modules. Only the VLAN entry with the vlanEntryIndex value of 1 will report this object with the value of enable(1), all other entries will have a value of disable(0)." ::= { vlanEntry 9 } vlanEntryVlanDefault OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies which vlanTable entry is the 'default entry'. By default, the entry with the vlanEntryIndex value of 1 will have this object set to true(1). Only one vlanTable entry can be designated as the VLAN default entry. Setting this object to true(1) for an entry will make this object false(0) for all other vlanTable entries. Only the vlanTable entry with this object set to true(1) will allow the vlanEntryTagging object to be configurable for this vlanEntryIndex index." ::= { vlanEntry 10 } vlanEntryIPv4StaticAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "This object sets the IP address for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to the IP address of the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP address of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1)." ::= { vlanEntry 31 } vlanEntryIPv4StaticGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "This object sets the IP address for the IP gateway for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to the IP gateway for the ethernet interface. The IP address of the default VLAN entry can only change by changing the IP gateway of the ethernet interface. For all other VLAN entries, this object may be set to any IP address except the IP address of the ethernet interface. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1)." ::= { vlanEntry 32 } vlanEntryIPv4StaticMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "This object sets the subnet mask for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to the subnet mask of the ethernet interface. The subnet mask of the default VLAN entry can only change by changing the subnet mask of the ethernet interface. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1)." ::= { vlanEntry 33 } vlanEntryIPv4SubnetRoute1 OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "This object sets the IP address of the subnet route 1 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1)." ::= { vlanEntry 51 } vlanEntryIPv4SubnetRouteMask1 OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "This object sets the subnet route mask 1 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1)." ::= { vlanEntry 52 } vlanEntryIPv4SubnetRoute2 OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "This object sets the IP address of the subnet route 2 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1)." ::= { vlanEntry 53 } vlanEntryIPv4SubnetRouteMask2 OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "This object sets the subnet route mask 2 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1)." ::= { vlanEntry 54 } vlanEntryIPv4SubnetRoute3 OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "This object sets the IP address of the subnet route 3 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet route. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1)." ::= { vlanEntry 55 } vlanEntryIPv4SubnetRouteMask3 OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "This object sets the subnet route mask 3 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object set to 0.0.0.0. For all other VLAN entries, this object may be set to any valid subnet mask. For a change of this object to take effect, the object, vlanEntryState, must be set to enable(1) if the vlanEntryState is currently disable(0), or set to restart(2) if the vlanEntryState is currently enable(1)." ::= { vlanEntry 56 } -- ******************************************************************************** -- TCP/IP Protocol Configuration -- ******************************************************************************** tcpProtocols OBJECT IDENTIFIER ::= { networkConfiguration 3 } -- ******************************************************************************** -- SNMP Agent Configuration -- ******************************************************************************** snmpAgentConfig OBJECT IDENTIFIER ::= { tcpProtocols 1 } snmpSystemContact OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..48)) ACCESS read-write STATUS mandatory DESCRIPTION "A NULL terminated 48 byte string that contains the SNMP agent contact name." ::= { snmpAgentConfig 1 } snmpSystemLocation OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..48)) ACCESS read-write STATUS mandatory DESCRIPTION "A NULL terminated 48 byte string that contains the SNMP agent location name." ::= { snmpAgentConfig 2 } snmpSystemAgentTrapsDisable OBJECT-TYPE SYNTAX INTEGER { trapsEnabled(0), trapsDisabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable or enable SNMP traps." ::= { snmpAgentConfig 3 } -- ******************************************************************************** -- SNMP Agent Community Configuration -- ******************************************************************************** snmpAgentCommunityConfig OBJECT IDENTIFIER ::= { snmpAgentConfig 4 } -- ******************************************************************************** -- SNMP Community Configuration table -- ******************************************************************************** snmpCommunityTable OBJECT-TYPE SYNTAX SEQUENCE OF SnmpCommunityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of SNMP Community entries" ::= { snmpAgentCommunityConfig 1 } snmpCommunityEntry OBJECT-TYPE SYNTAX SnmpCommunityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SNMP community entries" INDEX { snmpCommunityEntryIndex } ::= { snmpCommunityTable 1 } SnmpCommunityEntry ::= SEQUENCE { snmpCommunityEntryIndex INTEGER, snmpCommunityEntryCommunityName OCTET STRING, snmpCommunityEntryCommunityIpAddress1 OCTET STRING, snmpCommunityEntryCommunityIpAddress2 OCTET STRING, snmpCommunityEntryCommunityIpAddress3 OCTET STRING, snmpCommunityEntryCommunityViewType INTEGER, snmpCommunityEntryCommunityIpAddress4 OCTET STRING, snmpCommunityEntryCommunityIpAddress5 OCTET STRING, snmpCommunityEntryCommunityIpAddress6 OCTET STRING, snmpCommunityEntryCommunityIpAddress7 OCTET STRING, snmpCommunityEntryCommunityIpAddress8 OCTET STRING, snmpCommunityEntryCommunityIpAddress9 OCTET STRING, snmpCommunityEntryCommunityIpAddress10 OCTET STRING, snmpCommunityEntryCommunityIpAddress11 OCTET STRING, snmpCommunityEntryCommunityIpAddress12 OCTET STRING } snmpCommunityEntryIndex OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Index for SNMP Agent Community entry." ::= { snmpCommunityEntry 1 } snmpCommunityEntryCommunityName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "SNMP Community entry name." ::= { snmpCommunityEntry 2 } snmpCommunityEntryCommunityIpAddress1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address" ::= { snmpCommunityEntry 3 } snmpCommunityEntryCommunityIpAddress2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address" ::= { snmpCommunityEntry 4 } snmpCommunityEntryCommunityIpAddress3 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address" ::= { snmpCommunityEntry 5 } snmpCommunityEntryCommunityViewType OBJECT-TYPE SYNTAX INTEGER { read-Traps(1), write-Read-Traps(2), traps-Only(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Access Level of the SNMPv1 managers. Note this parameter is set for each community. Therefore all three managers in the same community have the same access level." ::= { snmpCommunityEntry 6 } snmpCommunityEntryCommunityIpAddress4 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address" ::= { snmpCommunityEntry 7 } snmpCommunityEntryCommunityIpAddress5 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address" ::= { snmpCommunityEntry 8 } snmpCommunityEntryCommunityIpAddress6 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address" ::= { snmpCommunityEntry 9 } snmpCommunityEntryCommunityIpAddress7 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address" ::= { snmpCommunityEntry 10 } snmpCommunityEntryCommunityIpAddress8 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address" ::= { snmpCommunityEntry 11 } snmpCommunityEntryCommunityIpAddress9 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address" ::= { snmpCommunityEntry 12 } snmpCommunityEntryCommunityIpAddress10 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address" ::= { snmpCommunityEntry 13 } snmpCommunityEntryCommunityIpAddress11 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address" ::= { snmpCommunityEntry 14 } snmpCommunityEntryCommunityIpAddress12 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "SNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two wildard values for read-Traps and write-Read-Traps communities: 0.0.0.0 - allow any IPv4 address 0::0 - allow any IPv6 address" ::= { snmpCommunityEntry 15 } snmpv1SystemAgentEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable or enable the SNMPv1 agent. NOTE: Restart the management module if this MIB object is changed with respect to the value at system bootup time. For example the SNMPv1 agent was set to disabled at system bootup time and now it is enabled. Then restarting the remote supervisor adaptor is required. Also note that when attempting to enable this agent, the following are verified: (1) Is there a valid system contact (2) Is there a valid system name (3) Is there at least one valid community name and for that community name is there one valid IP address or hostname (4) Are all defined community names unique If this verification fails an error response will be returned and the SNMPv1 agent will be left disabled." ::= { snmpAgentConfig 5 } snmpv3SystemAgentEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable or enable the SNMPv3 agent. NOTE: Restart the management module if this MIB object is changed with respect to the value at system bootup time. For example the SNMPv3 agent was set to disabled at system bootup time and now it is enabled. Then restarting the remote supervisor adaptor is required. Also note that when attempting to enable this agent, the following are verified: (1) Is there a valid system contact? (2) Is there a valid system name? If this verification fails an error response will be returned and the SNMPv3 agent will be left disabled." ::= { snmpAgentConfig 6 } -- ******************************************************************************** -- SNMP Agent User Profile Configuration -- ******************************************************************************** snmpAgentUserProfileConfig OBJECT IDENTIFIER ::= { snmpAgentConfig 9 } -- ******************************************************************************** -- SNMP User Profile Configuration table -- ******************************************************************************** snmpUserProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF SnmpUserProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of SNMPv3 User Profile entries" ::= { snmpAgentUserProfileConfig 1 } snmpUserProfileEntry OBJECT-TYPE SYNTAX SnmpUserProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SNMP User Profile entries" INDEX { snmpUserProfileEntryIndex } ::= { snmpUserProfileTable 1 } SnmpUserProfileEntry ::= SEQUENCE { snmpUserProfileEntryIndex INTEGER, snmpUserProfileEntryContextName OCTET STRING, snmpUserProfileEntryAuthProt INTEGER, snmpUserProfileEntryPrivProt INTEGER, snmpUserProfileEntryPrivPassword OCTET STRING, snmpUserProfileEntryViewType INTEGER, snmpUserProfileEntryIpAddress OCTET STRING } snmpUserProfileEntryIndex OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Index for SNMPv3 Agent User Profile entry." ::= { snmpUserProfileEntry 1 } snmpUserProfileEntryContextName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "SNMPv3 User Profile entry - Context name for users to access MIB objects. Note that context names can be duplicates and can be shared among users. Empty context names are allowed. The default context name is the empty string." ::= { snmpUserProfileEntry 3 } snmpUserProfileEntryAuthProt OBJECT-TYPE SYNTAX INTEGER { none (1), md5 (2), sha (3) } ACCESS read-write STATUS mandatory DESCRIPTION "SNMPv3 User Profile entry - Authentication Protocol supported by the user." ::= { snmpUserProfileEntry 4 } snmpUserProfileEntryPrivProt OBJECT-TYPE SYNTAX INTEGER { none (1), des (2), aes (4) } ACCESS read-write STATUS mandatory DESCRIPTION "SNMPv3 User Profile entry - Privacy Protocol supported by the user. The Privacy Password must be set and the Authentication Protocol must be md5 or sha before this field may be set to des or aes." ::= { snmpUserProfileEntry 6 } snmpUserProfileEntryPrivPassword OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "SNMPv3 User Profile entry - Privacy password for the user. NOTE: Value returned for the GET command is meaningless for this MIB object for security reasons." ::= { snmpUserProfileEntry 7 } snmpUserProfileEntryViewType OBJECT-TYPE SYNTAX INTEGER { read-Traps(1), read-Write-Traps(2), traps-Only(3) } ACCESS read-write STATUS mandatory DESCRIPTION "SNMPv3 User Profile entry - Access level (Get, Set, and Traps) of the user. " ::= { snmpUserProfileEntry 8 } snmpUserProfileEntryIpAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "SNMPv3 User Profile entry - IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name." ::= { snmpUserProfileEntry 9 } -- ******************************************************************************** -- DNS Configuration -- ******************************************************************************** dnsConfig OBJECT IDENTIFIER ::= { tcpProtocols 2 } dnsEnabled OBJECT-TYPE SYNTAX INTEGER { dnsDisabled(0), dnsEnabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable or enable the DNS agent. NOTE: To alter any of the configuration settings for the DNS agent, the following procedure should be used: (1) This object should be set to 'disabled' (2) Make the modifications to other settings (3) This object should be set to 'enabled' (4) Restart the management module Also note that when attempting to enable this agent, it is verified that there is at least one valid DNS server IP address. If this verification fails, an error response will be returned and the DNS agent will be left disabled." ::= { dnsConfig 1 } dnsServerIPAddress1 OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Contains the primary DNS server IP address." ::= { dnsConfig 2 } dnsServerIPAddress2 OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Contains the secondary DNS server IP address." ::= { dnsConfig 3 } dnsServerIPAddress3 OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Contains the tertiary DNS server IP address." ::= { dnsConfig 4 } dnsServerIPv6Address1 OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-write STATUS mandatory DESCRIPTION "Contains the primary IPv6 DNS server address." ::= { dnsConfig 12 } dnsServerIPv6Address2 OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-write STATUS mandatory DESCRIPTION "Contains the secondary IPv6 DNS server address." ::= { dnsConfig 13 } dnsServerIPv6Address3 OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-write STATUS mandatory DESCRIPTION "Contains the tertiary IPv6 DNS server address." ::= { dnsConfig 14 } dnsPriority OBJECT-TYPE SYNTAX INTEGER { ipv6(1), ipv4(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Tells the order host names are resolved. The options are to either first resolve with an IPv6 DNS server or to first resolve with an IPv6 DNS server." ::= { dnsConfig 20 } -- ******************************************************************************** -- SMTP Configuration -- ******************************************************************************** smtpConfig OBJECT IDENTIFIER ::= { tcpProtocols 3 } smtpServerNameOrIPAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "A NULL terminated 64 byte string that contains the SMTP server host name or IP address (a.b.c.d)." ::= { smtpConfig 1 } attachmentsToEmailAlerts OBJECT-TYPE SYNTAX INTEGER { noAttachments(0), attachServiceInformation(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates if the service information should be attached to an email alert." ::= { smtpConfig 2 } smtpEmailDomain OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "A NULL terminated string that contains the SMTP email domain. If this field is empty, the AMM IP address is used as the domain. However, some SMTP servers (e.g. - MS Exchange 2007) do not accept an IP address and instead require a domain name. This object can be used to set that email domain name." ::= { smtpConfig 3 } tcpApplicationConfig OBJECT IDENTIFIER ::= { tcpProtocols 4 } telnetInactivityTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Default is 120 seconds. Value of zero is no timeout. Max value is any positive 4 bytes value. Note that SSH also uses this timeout value to wait before disconnecting inactive SSH connections." ::= { tcpApplicationConfig 1 } commandModeInactivityTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The amount of time in seconds before the (Secure)TCP Command Mode times out. Default value of 0 means no timeout. Max value is any positive 4 byte value." ::= { tcpApplicationConfig 2 } secureCommandModeEnable OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Set Secure TCP Command Mode number of connections. AMM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. A value of 0 means disabled. If no valid server certificate is in place, Secure TCP Command Mode will not be allowed to set to enable. NOTE: System Management Software requires this to be enabled for secure communication to the AMM." ::= { tcpApplicationConfig 3 } commandModeEnable OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Set TCP Command Mode number of connections. AMM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. A value of 0 means disabled. NOTE: System Management Software requires this to be enabled for non-secure communication to the AMM." ::= { tcpApplicationConfig 4 } slpAddrType OBJECT-TYPE SYNTAX INTEGER { multicast(0), broadcast(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Set SLP address type to 0 (multicast) or 1 (broadcast). Note that when slpAddrType is set to broadcast value then the multicast address set in slpMulticastAddr will be ignored." ::= { tcpApplicationConfig 5 } slpMulticastAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Service Locator Protocol Multicast address" ::= { tcpApplicationConfig 6 } slpEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable Service Location Protocol. NOTE: Change to Service Location Protocol will take effect after the next restart of the MM." ::= { tcpApplicationConfig 7} telnetEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable telnet. NOTE: Change to telnet enable/disable will take effect immediately." ::= { tcpApplicationConfig 9 } sshEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable SSH." ::= { tcpApplicationConfig 10 } sshVersion OBJECT-TYPE SYNTAX INTEGER { allVersions(0), -- deprecated version2Only(1) } ACCESS read-write STATUS mandatory DESCRIPTION "When SSH is enabled, this object allows the user to configure whether the SSH server accepts all versions of client connections or whether it restricts the connectivity to the more secure version 2 only. NOTE: Only SSH version 2 is supported now." ::= { tcpApplicationConfig 11 } sslServerEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable SSL Server." ::= { tcpApplicationConfig 15 } sslClientEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable SSL Client. If no valid client or server certificate is in place, SSL client will not be allowed to set to enable." ::= { tcpApplicationConfig 16 } ftpEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable FTP." ::= { tcpApplicationConfig 17 } tftpEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable TFTP." ::= { tcpApplicationConfig 19 } smashTelnetEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over Telnet. This option is not available on all systems." ::= { tcpApplicationConfig 20 } smashSshEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over SSH. A valid SSH server key must be installed before enabling secure SMASH. This option is not available on all systems." ::= { tcpApplicationConfig 21 } tftpCreateEmptyFile OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS deprecated DESCRIPTION "This MIB object is no longer a requirement for TFTP and has been deprecated." ::= { tcpApplicationConfig 22 } ftpTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The amount of time before FTP times out. Default is 300 seconds. Value of zero is no timeout. Max value is any positive 4 byte value." ::= { tcpApplicationConfig 23 } rdEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable Remote Disk. NOTE: Change to Remote Disk will take effect after the next restart of the MM." ::= { tcpApplicationConfig 24 } rdocEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable Remote Disk on Card. NOTE: Change to Remote Disk on Card will take effect after the next restart of the MM." ::= { tcpApplicationConfig 25 } kvmEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable KVM. NOTE: Change to KVM will take effect after the next restart of the MM." ::= { tcpApplicationConfig 26 } -- The SSH Server Configuration Group mmSshServerConfig OBJECT IDENTIFIER ::= { tcpApplicationConfig 27 } mmSshServerHostKeyTable OBJECT-TYPE SYNTAX SEQUENCE OF MmSshServerHostKeyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains per public/private host key pair information." ::= { mmSshServerConfig 1 } mmSshServerHostKeyEntry OBJECT-TYPE SYNTAX MmSshServerHostKeyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of information about a particular public/private host key pair." INDEX { mmSshServerHostKeyIndex } ::= { mmSshServerHostKeyTable 1 } MmSshServerHostKeyEntry ::= SEQUENCE { mmSshServerHostKeyIndex INTEGER, mmSshServerHostKeyType INTEGER, mmSshServerHostKeySize INTEGER, mmSshServerHostKeyFingerprint OCTET STRING } mmSshServerHostKeyIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the public/private host key pair." ::= { mmSshServerHostKeyEntry 1 } mmSshServerHostKeyType OBJECT-TYPE SYNTAX INTEGER { sshDss (1), sshRsa (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of the public/private host key pair." ::= { mmSshServerHostKeyEntry 2 } mmSshServerHostKeySize OBJECT-TYPE SYNTAX INTEGER { bits512 (1), bits768 (2), bits1024 (3), bits2048 (4), bits4096 (5) } ACCESS read-only STATUS mandatory DESCRIPTION "The size of the public/private host key pair. NOTE: The AMM supports only the bits2048 value." ::= { mmSshServerHostKeyEntry 3 } mmSshServerHostKeyFingerprint OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The RSA fingerprint of the public part of the host key pair. This value can be used with the SSH client to verify, on the initial connection, that the Secure Shell server responding to the request is the server running on the AMM. " ::= { mmSshServerHostKeyEntry 4 } mmSshServerHostKeyGenerate OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Initiate the new Host Keys generation process for the AMM SSH Server. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { mmSshServerConfig 2 } mmSshServerHostKeyGenerateProgress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the progress of the key generation process." ::= { mmSshServerConfig 3 } rpEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable Remote Presence." ::= { tcpApplicationConfig 28 } -- TCP Port Assignment tcpPortAssignmentCfg OBJECT IDENTIFIER ::= { tcpProtocols 5 } tcpPortsRestoreDefault OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset all ports to default value. http: 80 https: 443 telnet: 23 ssh: 22 SNMP agent: 161 SNMP trap: 162 TCP Command Mode: 6090 Secure TCP Command Mode: 6091 Remote Disk: 1044 Remote Disk-on-Card: 1045 Remote KVM: 3900 FTP: 21 FTP Data: 20 TFTP: 69 SMASH telnet: 50023 SMASH ssh: 50022 SLP: 427 Storage Description Service: 1046 NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { tcpPortAssignmentCfg 1 } httpPortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number. Default value is 80. Once changed, the URL's have to include :port at the end." ::= { tcpPortAssignmentCfg 2 } httpsPortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "SSL port number. Default value is 443. Once changed, the URL's have to include :port at the end." ::= { tcpPortAssignmentCfg 3 } telnetPortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Telnet port number. Default value is 23. Port change will take effect immediately." ::= { tcpPortAssignmentCfg 4 } sshPortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "SSH port number. Default value is 22." ::= { tcpPortAssignmentCfg 5 } snmpAgentPortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "SNMP Agent port number. Default value is 161. Changes take effect after several seconds." ::= { tcpPortAssignmentCfg 6 } snmpTrapsPortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "SNMP Traps port number. Default value is 162. Changes take effect after several seconds." ::= { tcpPortAssignmentCfg 7 } commandModePortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "TCP Command Mode port number. Default value is 6090. Change will take effect immediately." ::= { tcpPortAssignmentCfg 8 } secureCommandModePortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Secure TCP Command Mode port number. Default value is 6091. Change will take effect immediately." ::= { tcpPortAssignmentCfg 9 } rdPortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS deprecated DESCRIPTION "Remote Disk port number. Default value is 1044. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object. Attempts to set the port value for this SNMP object are no longer supported and any read of the value associated with this object will return the rpPortAssignment (Remote Presence) port information." ::= { tcpPortAssignmentCfg 10 } rdocPortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS deprecated DESCRIPTION "Remote Disk-on-Card port number. Default value is 1045. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object. Attempts to set the port value for this SNMP object are no longer supported and any read of the value associated with this object will return the rpPortAssignment (Remote Presence) port information." ::= { tcpPortAssignmentCfg 11 } kvmPortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS deprecated DESCRIPTION "Remote KVM port number. Default value is 3900. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object. Attempts to set the port value for this SNMP object are no longer supported and any read of the value associated with this object will return the rpPortAssignment (Remote Presence) port information." ::= { tcpPortAssignmentCfg 12 } ftpPortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "FTP port number. Default value is 21. Port change will take effect immediately." ::= { tcpPortAssignmentCfg 13 } ftpDataPortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "FTP Data port number. Default value is 20. Port change will take effect immediately." ::= { tcpPortAssignmentCfg 14 } tftpPortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "TFTP port number. Default value is 69." ::= { tcpPortAssignmentCfg 15 } smashTelnetPortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The port number for SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over telnet. Default value is 50023. Change will take effect immediately. This option is not available on all systems." ::= { tcpPortAssignmentCfg 17 } smashSshPortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The port number for SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over SSH. Default value is 50022. This option is not available on all systems." ::= { tcpPortAssignmentCfg 18 } slpPortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Service Location Protocol port number. Default value is 427. NOTE: This value is normally required to be 427 to interoperate properly with other SLP enabled applications." ::= { tcpPortAssignmentCfg 19 } sdsPortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS deprecated DESCRIPTION "Storage description service port number. Default value is 1046. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object. Attempts to set the port value for this SNMP object are no longer supported and any read of the value associated with this object will return the rpPortAssignment (Remote Presence) port information." ::= { tcpPortAssignmentCfg 20 } rpPortAssignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Remote Presence port. Default value is 3900. This port cannot be disabled since it is the single service entry point for all the services provided by AMM RPServ to clients." ::= { tcpPortAssignmentCfg 21 } -- LDAP Client Configuration ldapClientCfg OBJECT IDENTIFIER ::= { tcpProtocols 6 } ldapServer1NameOrIPAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) ACCESS read-write STATUS mandatory DESCRIPTION "A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d)." ::= { ldapClientCfg 1 } ldapServer1PortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "LDAP server port number." ::= { ldapClientCfg 2 } ldapServer2NameOrIPAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) ACCESS read-write STATUS mandatory DESCRIPTION "A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d)." ::= { ldapClientCfg 3 } ldapServer2PortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "LDAP server port number." ::= { ldapClientCfg 4 } ldapServer3NameOrIPAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) ACCESS read-write STATUS mandatory DESCRIPTION "A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d)." ::= { ldapClientCfg 5 } ldapServer3PortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "LDAP server port number." ::= { ldapClientCfg 6 } ldapRootDN OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) ACCESS read-write STATUS mandatory DESCRIPTION "A NULL terminated 255 byte string that contains the distinguished Name for root entry of directory tree. An example might look like dn=foobar,dn=com." ::= { ldapClientCfg 7 } ldapUserSearchBaseDN OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) ACCESS read-write STATUS deprecated DESCRIPTION "As part of the user authentication process, it is necessary to search the LDAP server for one or more attributes associated with a particular user. Any search request must specify the base DN for the actual search. This field specifies the base DN which should be used to search the User directory. This is a NULL terminated 255 byte string. An example might look like cn=users,dn=foobar,dn=com. If this field is left blank, the Root DN will be used as the search base instead. As mentioned, user searches are part of the authentication process. They are carried out to retrieve information about the user such as login permissions, callback number, and group memberships. For Version 2.0 LDAP clients, it is strongly encouraged that this parameter be configured, otherwise a search using the root DN may not succeed (as seen on Active Directory servers). NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported." ::= { ldapClientCfg 8 } ldapGroupFilter OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..511)) ACCESS read-write STATUS mandatory DESCRIPTION "This filter is used for group authentication. It specifies what group or groups that this MM belongs to. If left blank, group authentication is disabled. Otherwise, group authentication will be performed against the filter. The filter can be a specific group name (e.g. RSAWest), a wildcard (*) which matches everything, or a wildcard with a prefix (e.g. RSA*). The default filter is RSA*. After user authentication, group authentication will take place, whereby an attempt will be made to match the group or groups (that the user belongs to) to the group filter defined here. If there is no match, the user will not pass authentication and will be blocked. If there is a match, the login permissions for the user will be retrieved from the matched group(s), unless the user already has login permissions assigned directly from the user record retrieved from the LDAP server." ::= { ldapClientCfg 9 } ldapBindingMethod OBJECT-TYPE SYNTAX INTEGER { anonymousAuthentication(0), clientAuthentication(1), userPrincipalName(2), strictUserPrincipalName(3) } ACCESS read-write STATUS mandatory DESCRIPTION "On initial binds to the LDAP server during user authentication, there are three options: Anonymous authentication: Bind attempt is made without a client DN or password. If the bind is successful, a search will be requested in order to find an entry on the LDAP server for the user attempting to login. If an entry is found, a second attempt to bind will be attempted, this time with the user's DN and password. If this succeeds, the user is deemed to have passed the user authentication phase. Group authentication is then attempted if it is enabled. Client authentication: Bind attempt is made with client DN and password specified by this configuration parameter. If the bind is successful, we proceed as above. User Principal Name (UPN): Bind attempt is made directly with the credentials used during the login process. If this succeeds, the user is deemed to have passed the user authentication phase. Note that for Active Directory servers, the userid can have the form someuser@somedomain or simply someuser. Strict UPN: This is the same as UPN above, except that the userid must have the form someuser@somedomain. The string entered by the user will be parsed for the @ symbol. NOTE: strictUserPrincipalName(3) option is available on MM only." ::= { ldapClientCfg 10 } ldapClientAuthenticationDN OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "The initial bind to the LDAP server during user authentication can be performed with anonymous authentication, client based authentication, or UPN. The client based option requires a client DN and password as parameters to the bind request. The client DN is a NULL terminated 255 byte string. These parameters are configured here. Note that the password can be left blank." ::= { ldapClientCfg 11 } ldapClientAuthenticationPassword OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) ACCESS read-write STATUS mandatory DESCRIPTION "The client authentication password" ::= { ldapClientCfg 12 } ldapUIDsearchAttribute OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "When the binding method selected is Anonymous authentication or Client authentication, the initial bind to the LDAP server is followed by a search request aimed at retrieving specific information about the user, including the user's DN, login permissions, and group ownerships. In order to retrieve this information, the search request must specify the attribute name used to represent userids on that server. Specifically, this name is used as a search filter against the login id entered by the user. This attribute name is configured here. If this field is left blank, a default of uid is used during user authentication. For example, on Active Directory servers, the attribute name used for userids is often sAMAccoutName. When the binding method selected is UPN or Strict UPN, this field defaults automatically to userPrincipalName during user authentication if the userid entered has the form userid@somedomain." ::= { ldapClientCfg 13 } ldapGroupSearchAttribute OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "When the MM Group Filter name is configured, it is necessary to retrieve from the LDAP server the list of groups that a particular user belongs to. This is required to do group authentication. In order to retrieve this list, the search filter sent to the server must specify the attribute name associated with groups. This field specifies this attribute name. If this field is left blank, the attribute name in the filter will default to memberOf." ::= { ldapClientCfg 14 } ldapLoginPermissionAttribute OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "When a user successfully authenticates via a LDAP server, it is necessary to retrieve the login permissions for this user. In order to retrieve these permissions, the search filter sent to the server must specify the attribute name associated with login permissions. This field specifies this attribute name." ::= { ldapClientCfg 15 } ldapUseDNSOrPreConfiguredServers OBJECT-TYPE SYNTAX INTEGER { usePreConfiguredLDAPServers (0), useDNSToFindLDAPServers (1) } ACCESS read-write STATUS mandatory DESCRIPTION "The MM contains a Version 2.0 LDAP Client that may be configured to provide user authentication through one or more LDAP servers. The LDAP server(s) to be used for authentication can be discovered dynamically or manually pre-configured. If the usePreConfiguredLDAPServers option is selected, up to 4 LDAP servers can be configured. Simply enter the server's IP address or hostname (assuming DNS is enabled). The port number for each server is optional. If left blank, the default value of 389 is used for non-secured LDAP connections. For secured connections, the default is 636. At least one server must be configured. If the useDNSToFindLDAPServers is selected, the domain name need to be provided. For LDAP Authentication Only mode, additional information such as the forest name also need to be provided." ::= { ldapClientCfg 16 } ldapDomainSource OBJECT-TYPE SYNTAX INTEGER { extractSearchDomainFromLoginID (0), useOnlyConfiguredSearchDomainBelow (1), tryLoginFirstThenConfiguredValue (2) } ACCESS read-write STATUS deprecated DESCRIPTION "The DNS SRV request sent to the DNS server must specify a domain name. The LDAP client will determine where to get this domain name based on one of the following three options: - extractSearchDomainFromLoginID: With this option, the LDAP client will use the domain name in the login id. For example, if the login id is joesmith@mycompany.com, the domain name equals mycompany.com. If the domain name cannot be extracted, the DNS SRV will fail, causing the user authentication to fail automatically. - useOnlyConfiguredSearchDomainBelow: With this option, the LDAP client will use the domain name configured in the Search Domain parameter. - tryLoginFirstThenConfiguredValue: With this option, the LDAP client will first attempt to extract the domain name from the login id. If this succeeds, this domain name will be used in the DNS SRV request. If there is no domain name present in the login id, the LDAP client will instead use the configured Search Domain parameter as the domain name in the DNS SRV request. If nothing is configured, user authentication will fail immediately." ::= { ldapClientCfg 17 } ldapSearchDomain OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-write STATUS deprecated DESCRIPTION "This parameter may be used as the domain name in the DNS SRV request, depending on how the Domain Source parameter is configured." ::= { ldapClientCfg 18 } ldapServiceName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) ACCESS read-write STATUS deprecated DESCRIPTION "The DNS SRV request sent to the DNS server must also specify a service name. The configured value will be used for this purpose. If left blank, the default value used is 'ldap'. Note that the DNS SRV request must also specify a protocol name. This defaults to 'tcp' and is not configurable." ::= { ldapClientCfg 19 } ldapRBSModelCfg OBJECT-TYPE SYNTAX INTEGER { oldPermissionString(0), newRBSModel(1) } ACCESS read-write STATUS mandatory DESCRIPTION "There are two mechanisms to authenticate and authorize users on the AMM when using an LDAP-enabled server. The first mechanism (oldPermissionString), also known as version 1, uses bitstrings to associate permissions to users and groups. Version1 supports Active Directory, Novell eDirectory, and OPenLDAP based servers. The second mechanism (newRBSModel), also known as version 2, uses a new Role-Based-Security (RBS) model. This mechanism is only available for Active Directory servers, and requires the use of a snap-in that runs on any windows platform. This snap-in tool allows you to configure roles on an Active Directory server of your choice, and to associate users/groups and AMMs to those roles. A role identifies the permissions given to users and groups associated with that role, and also identifies the targets (e.g. AMM) to which this role is attached. The use of bitstrings in version 2 disappears, making the configuration much more manageable and user-friendly. Note that if you are not using Active Directory, then you should not enable version 2. Also note that before enabling version 2, you should already have your roles configured on your Active Directory server. The old version 1 bitstring model cannot be automatically converted to the new version 2 model. This is why you must configure your users and groups before enabling version 2. Once enabled, the change takes effect immediately. The default value for this field is oldPermissionString." ::= { ldapClientCfg 20 } ldapTargetName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) ACCESS read-write STATUS mandatory DESCRIPTION "When administrator chooses Enhanced Role Based Security authentication model, he can associate one AMM with one managed target object in Snap-in (one tool to configure LDAP users permission) via one target name. The AMM target name can be looked as alias of AMM, administrator can change it according to his configuration requirements. This is a string of up to 63 characters (plus the null character)" ::= { ldapClientCfg 21 } ldapAuthCfg OBJECT-TYPE SYNTAX INTEGER { authenticationAndAuthorization(0), authenticationOnly(1) } ACCESS read-write STATUS mandatory DESCRIPTION "If ldapAuthCfg is set to 0, LDAP server is used to authenticate and authorize users. If it is set to 1, LDAP server is only used to authenticate users. Note:LDAP Authentication Only mode is currently supported only in an Active Directory environment." ::= { ldapClientCfg 22 } ldapForestName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "LDAP Forest Name. Note: LDAP Forest Name is only for Active Directory environment." ::= { ldapClientCfg 23 } ldapDomainName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) ACCESS read-write STATUS mandatory DESCRIPTION "A NULL terminated 255 byte string that contains the LDAP Domain Name." ::= { ldapClientCfg 24 } ldapServer4NameOrIPAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) ACCESS read-write STATUS mandatory DESCRIPTION "A NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d)." ::= { ldapClientCfg 25 } ldapServer4PortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "LDAP server port number." ::= { ldapClientCfg 26 } -- ******************************************************************************** -- Uplink Check Configuration -- ******************************************************************************** uplinkCheckConfig OBJECT IDENTIFIER ::= { tcpProtocols 7 } uplinkCheckEnabled OBJECT-TYPE SYNTAX INTEGER { uplinkCheckDisabled(0), uplinkCheckEnabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable or enable network uplink checking for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { uplinkCheckConfig 1 } uplinkCheckDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Delay, in minutes (1-2880), between discovery of a failed network uplink and the subsequent MM failover for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { uplinkCheckConfig 2 } logicalUplinkDestination OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Destination IP for MM to check its logical link. Specify a non-zero IP Address in order to enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { uplinkCheckConfig 3 } logicalUplinkCheckEnabled OBJECT-TYPE SYNTAX INTEGER { uplinkCheckDisabled(0), uplinkCheckEnabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable or enable network uplink checking for logical detection. logicalUplinkDestination must be set to a non-zero IP Address before enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { uplinkCheckConfig 4 } logicalUplinkCheckDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Delay, in minutes(1-2880), between discovery of a failed network uplink and the subsequent MM failover for logical detection. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { uplinkCheckConfig 5 } physicalUplinkCheckDelayInSecs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Delay, in seconds(10-172800), between discovery of a failed network uplink and the subsequent MM failover for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { uplinkCheckConfig 6 } logicalUplinkCheckDelayInSecs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Delay, in seconds(60-172800), between discovery of a failed network uplink and the subsequent MM failover for logical detection. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { uplinkCheckConfig 7 } logicalUplinkIPv6Destination OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-write STATUS mandatory DESCRIPTION "Destination IP for MM to check its logical link using IPv6. Specify a non-zero IP Address in order to enable logical uplink checking. NOTE: This MIB object is only applicable to systems with a standby MM. NOTE: This MIB object is only applicable if IPv6 is enabled on the MM." ::= { uplinkCheckConfig 8 } logicalUplinkFailoverPolicy OBJECT-TYPE SYNTAX INTEGER { either(1), both(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines when to failover if both an IPv4 and IPv6 destination have been configured. If set to 'either' the system will failover if either of the destination's link check fails. If set to 'both' then the IPv4 and IPv6 link checks must fail before a failover will happen. NOTE: This MIB object is only applicable to systems with a standby MM." ::= { uplinkCheckConfig 9 } -- ******************************************************************************** -- NTP Configuration -- ******************************************************************************** ntpConfig OBJECT IDENTIFIER ::= { tcpProtocols 8 } ntpEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable the NTP client. The client will update the AMM system clock at the frequency specified." ::= { ntpConfig 1 } ntpIpAddressHostname OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "NTP server's IP address or hostname if DNS is enabled and configured." ::= { ntpConfig 2 } ntpUpdateFrequency OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The frequency in minutes that the NTP service runs. The value range is 0 to 45000. If the NTP update frequency is set to 0, the AMM clock can only be synchronized with the NTP server manually." ::= { ntpConfig 3 } ntpLastUpdate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The date and time that the NTP server last updated the system clock." ::= { ntpConfig 4 } ntpUpdateClock OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Update the AMM system clock with the specified NTP server. A valid NTP server must be configured first." ::= { ntpConfig 5 } ntpAuthEntry OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The NTP v3 authentication entry to be used for time sync with a secure NTP server. The format of an authentication entry is . must be an integer between 1 and 65535. must be M. is the actual value of the authentication key as configured on the NTP server. The GET command returns back data in the format: It does not return the actual key." ::= { ntpConfig 6 } ntpAuthEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables/Disables NTP v3 authentication" ::= { ntpConfig 7 } -- ******************************************************************************** -- SYSLOG Configuration -- ******************************************************************************** syslogConfig OBJECT IDENTIFIER ::= { tcpProtocols 9 } syslogSevFilterLevel OBJECT-TYPE SYNTAX INTEGER { error(0), warning(1), information(2) } ACCESS read-write STATUS mandatory DESCRIPTION "syslogSevFilterLevel error/warning/information ." ::= { syslogConfig 1 } -- ******************************************************************************** -- syslogCollector Configuration -- ******************************************************************************** syslogCollectorConfig OBJECT IDENTIFIER ::= { syslogConfig 2 } -- ******************************************************************************** -- Syslog Collector Configuration table -- ******************************************************************************** syslogCollectorTable OBJECT-TYPE SYNTAX SEQUENCE OF SyslogCollectorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Syslog Collector entries" ::= { syslogCollectorConfig 1 } syslogCollectorEntry OBJECT-TYPE SYNTAX SyslogCollectorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Syslog Collector entries" INDEX { syslogCollectorIndex } ::= { syslogCollectorTable 1 } SyslogCollectorEntry ::= SEQUENCE { syslogCollectorIndex INTEGER, syslogCollectorHostnameOrIpAddress OCTET STRING, syslogCollectorPort INTEGER, syslogCollectorEnable INTEGER } syslogCollectorIndex OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Index for Syslog Collector entry." ::= { syslogCollectorEntry 1 } syslogCollectorHostnameOrIpAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "Syslog Collector IP address or host name." ::= { syslogCollectorEntry 2 } syslogCollectorPort OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Syslog Collector port number." ::= { syslogCollectorEntry 3 } syslogCollectorEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Syslog Collector enable/disable." ::= { syslogCollectorEntry 4 } -- ******************************************************************************** -- Generate test syslog packet -- ******************************************************************************** syslogTestPacket OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Generate a test syslog packet. This will send a test syslog to all configured and enabled syslog collectors to assist in validating the configuration. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { syslogConfig 3 } -- ******************************************************************************** -- SOL (Serial Over LAN) Configuration -- ******************************************************************************** solConfiguration OBJECT IDENTIFIER ::= { configureSP 10 } -- ******************************************************************************** -- SOL Global Configuration -- ******************************************************************************** solGlobalConfig OBJECT IDENTIFIER ::= { solConfiguration 1 } solEnable OBJECT-TYPE SYNTAX INTEGER { solDisabled(0), solEnabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable SOL dynamically." ::= { solGlobalConfig 1 } solVlanId OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This is the virtual LAN ID for the internal management network between the MM and the Blade System Management Processors (BSMPs). The range of valid VLAN ID's is 3 to 4095." ::= { solGlobalConfig 2 } solAccumulateTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This value specifies how much time in millisecond SOL to buffer data before sending the next SOL packet since the last SOL packet was transmitted. Valid value from 5 ms to 1275 ms. The value is in 5 ms increment. Value is not in 5 ms increment will be truncated to a nearest 5s. Default value is 5 ms." ::= { solGlobalConfig 3 } solCharSendThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This value specifies how many characters SOL to buffer before sending the next SOL packet since the last SOL packet was transmitted. Valid value is from 1 to 255" ::= { solGlobalConfig 4 } solRetry OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Retry count. Valid value from 0-7. 0 means no retries after packet is transmitted. Packet will be dropped if no ACK/NACK received by the time retries expired." ::= { solGlobalConfig 5 } solRetryInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Retry Interval in 10 ms increment. Sets the time that the SOL will wait before the first retry and the time between retries when sending SOL packets to the remote blade. Value range is from 0 to 2550 ms in 10 ms increment. 0 means retries will be sent back-to-back." ::= { solGlobalConfig 6 } solExitToCliKeySeq OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..16)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the keystroke sequence used to escape out of SOL session and back to CLI console. This sequence must have at least one character. The caret symbol (^) has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage return). All occurrences of ^ will be interpreted as part of a Ctrl sequence. Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences. The default value for this field is '^[(' i.e. ESC followed by (." ::= { solGlobalConfig 7 } solResetBladeKeySeq OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..16)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the keystroke sequence used to reset the blade while in SOL session console. This sequence must have at least one character. The caret symbol (^) has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage return). All occurrences of ^ will be interpreted as part of a Ctrl sequence. Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences. The default value for this field is '^[R^[r^[R' i.e. ESC R ESC r ESC R." ::= { solGlobalConfig 8 } -- Blade SOL config solBladeConfig OBJECT IDENTIFIER ::= { solConfiguration 2 } solBladeTable OBJECT-TYPE SYNTAX SEQUENCE OF SolBladeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SOL Blade configuration table." ::= { solBladeConfig 1 } solBladeEntry OBJECT-TYPE SYNTAX SolBladeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SOL Blade table entry" INDEX { solBladeIndex } ::= { solBladeTable 1 } SolBladeEntry ::= SEQUENCE { solBladeIndex INTEGER, solBladeName OCTET STRING, solBladeEnable INTEGER, solBladeIpAddr IpAddress, solBladeSessionStatus INTEGER, solBladeCapability INTEGER } solBladeIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SOL Blade table index." ::= { solBladeEntry 1 } solBladeName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the blade as a null terminated string." ::= { solBladeEntry 2 } solBladeEnable OBJECT-TYPE SYNTAX INTEGER { solBladeDisabled(0), solBladeEnabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable or enable a SOL on a blade." ::= { solBladeEntry 3 } solBladeIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP address of the blade derived from the IP address range for the blade system management processors on the blades. NOTE: The IPv6 address for a blade can be view with the bladeIPv6AddressTable." ::= { solBladeEntry 4 } solBladeSessionStatus OBJECT-TYPE SYNTAX INTEGER { solSessionNotReady(0), solSessionReady(1), solSessionActive(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of a blade SOL session: solSessionNotReady: no SOL session connected to the blade. solSessionReady: there is an SOL session to the blade. solSessionActive: there is an SOL session to the blade and there is a client using the SOL session." ::= { solBladeEntry 5 } solBladeCapability OBJECT-TYPE SYNTAX INTEGER { notSupport(0), support(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Display whether or not the blade support SOL feature." ::= { solBladeEntry 6 } -- ******************************************************************************** -- Chassis Internal Network (CIN) -- ******************************************************************************** chassisInternalNetwork OBJECT IDENTIFIER ::= { configureSP 11} -- Maximum number of CIN definitions supported cinsSupported OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of Chassis Internal Network (CIN) definitions supported. Currently a maximum of 14 CIN definitions can be supported." ::= { chassisInternalNetwork 1 } -- CIN Global Configuration cinGlobalEnable OBJECT-TYPE SYNTAX INTEGER { cinDisabled(0), cinEnabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable Chassis Internal Network (CIN) function dynamically. Enabled: AMM reads the CIN entries. For each enabled entry, - If the CIN VLAN ID is new and does not have a CIN interface created yet then create a new CIN interface based on that CIN VLAN ID. Use the CIN IP address from the entry to create a host route. - If the CIN IP address is 0.0.0.0 then start ARP monitoring. Disabled: - Stop all ARP monitoring. - Delete all host routes. - Delete all CIN interfaces." ::= { chassisInternalNetwork 2 } -- CIN Configuration Table cinTable OBJECT-TYPE SYNTAX SEQUENCE OF CinEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Chassis Internal Network (CIN) configuration table." ::= { chassisInternalNetwork 3} cinEntry OBJECT-TYPE SYNTAX CinEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Chassis Internal Network (CIN) table entry." INDEX { cinIndex } ::= { cinTable 1 } CinEntry ::= SEQUENCE { cinIndex INTEGER, cinDefExists INTEGER, cinDelete INTEGER, cinEnable INTEGER, cinId INTEGER, cinIpAddress IpAddress, cinIpv6Address InetAddressIPv6 } cinIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Chassis Internal Network (CIN) table index." ::= { cinEntry 1 } cinDefExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if a Chassis Internal Network (CIN) definition exists for this index or not." ::= { cinEntry 2 } cinDelete OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Delete Chassis Internal Network (CIN) definition. Works like CIN entry disabled. However, the entry is also deleted. NOTE: Value returned for the GET command is meaningless for this MIB object. Deleting a non-defined entry does nothing." ::= { cinEntry 3 } cinEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable or enable a Chassis Internal Network (CIN) definition. Enabled: AMM reads the entry and creates a new CIN interface if the CIN VLAN ID is new and does not have a CIN interface created yet, adds host route, and monitors communication path. Start ARP monitoring if IP is 0.0.0.0. Disabled: Delete host route. If this is the last IP address that uses the CIN interface, - Stop ARP monitoring if IP is 0.0.0.0. - Delete the CIN interface if there is no other entry depends on it." ::= { cinEntry 4 } cinId OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This is the Chassis Internal Network (CIN) Virtual LAN (VLAN) ID for the internal management network between the Management Module, I/O Module, and the blade OS. The range of valid CIN VLAN IDs is 3 to 4094 (inclusive). This value cannot be the same as the Serial Over LAN (SOL) or Concurrent KVM (cKVM) VLAN ID. NOTE: If creating a new CIN definition, you must define cinId before you define cinIpAddress. NOTE: Before changing this value on an existing CIN definition, you must first disable the definition." ::= { cinEntry 5 } cinIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Chassis Internal Network (CIN) IP address. Restrictions: - CIN entries cannot have matching IP addresses, with the exception of 0.0.0.0. - Multiple IP addresses of 0.0.0.0 with different VLAN IDs are allowed. - The IP address cannot be multi-cast. - The IP address cannot match the AMM IP address. - If the CIN IP address is 0.0.0.0, the blade IP address for CIN which is configured in the blade's OS can not be in the same subnet as that of AMM. NOTE: If creating a new CIN definition, you must define cinId before you define cinIpAddress. NOTE: Before changing this value on an existing CIN definition, you must first disable the definition. NOTE: When ipv6 is enable on one interface, this column will display all zero IPv4 address" ::= { cinEntry 6} cinIpv6Address OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-write STATUS mandatory DESCRIPTION "Chassis Internal Network (CIN) IPv6 address NOTE: When ipv4 is enable on one interface,this column will display all zero IPv6 address. " ::= { cinEntry 7} -- CIN Status Table cinStatus OBJECT IDENTIFIER ::= { chassisInternalNetwork 4 } cinStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF CinStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Chassis Internal Network (CIN) status entry information." ::= { cinStatus 1 } cinStatusEntry OBJECT-TYPE SYNTAX CinStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Chassis Internal Network (CIN) status table entry." INDEX { cinStatusIndex } ::= { cinStatusTable 1 } CinStatusEntry ::= SEQUENCE { cinStatusIndex INTEGER, cinStatusString OCTET STRING } cinStatusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Chassis Internal Network (CIN) status log index number. For consistent results, view as a table and not as individual entries." ::= { cinStatusEntry 1 } cinStatusString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Status of a Chassis Internal Network (CIN) connection. For example: Index:1 VLANID:4094 IPADDR:192.168.70.100 MAC:01:0A:0B:00:01:01 Type:Learned Status:Operational Index is the status entry number in the status table. Followed by the VLAN ID, IP address, and MAC address that the Management Module is communicating with on the CIN connection. Type is either 'Configured' or 'Learned'. Learned implies that the Management Module dynamically discovered the IP address. Configured means that the address was explicitly configured in the Management Module. Status can be 'Operational', 'Not Operational', or 'Disabled'. 'Operational' means the Management Module can ping the CIN IP address. 'Not Operational' means that the Management Module cannot ping the CIN IP address. Verify that the blade and I/O Module are configured properly and that their configurations are compatible with the Management Module. The blade OS also needs to have an IP host route defined (e.g. route add -host 192.168.70.100 eth0.4094). I/O Modules need to have a VLAN defined containing the blade's and the AMM's port. Blade and I/O Modules need to be powered up and operational. 'Disabled' means that the CIN configuration has been disabled by a Management Module administrator. For consistent results, view as a table and not as individual entries." ::= { cinStatusEntry 2 } -- CIN Port Configuration Table cinPortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF CinPortConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Chassis Internal Network (CIN) configuration table for viewing and configuring the protocol port information for a particular CIN entry." ::= { chassisInternalNetwork 5} cinPortConfigEntry OBJECT-TYPE SYNTAX CinPortConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Chassis Internal Network (CIN) entry for viewing and configuring the protocol port information for a particular CIN entry." INDEX { cinPortConfigCINIndex, cinPortConfigIndex } ::= { cinPortConfigTable 1 } CinPortConfigEntry ::= SEQUENCE { cinPortConfigCINIndex INTEGER, cinPortConfigIndex INTEGER, cinPortConfigProtocolID INTEGER, cinPortConfigExternalPort INTEGER, cinPortConfigInternalPort INTEGER, cinPortConfigEnable INTEGER, cinPortConfigDirection INTEGER } cinPortConfigCINIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The identifier for the particular CIN configuration that these protocol port definitions are associated with. This object is the same as the cinIndex value in the cinTable." ::= { cinPortConfigEntry 1 } cinPortConfigIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The identifier of a particular CIN protocol port configuration for a given CIN configuration as specified by cinPortConfigCINIndex. There can be up to 16 unique protocol port definitions per CIN configuration." ::= { cinPortConfigEntry 2 } cinPortConfigProtocolID OBJECT-TYPE SYNTAX INTEGER { tcp(1), udp(2), notDefined(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the port protocol definition is for a TCP or UDP port. If the value of notDefined(3) is returned, the entry has yet to be configured." ::= { cinPortConfigEntry 3 } cinPortConfigExternalPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The external port number specified for this port protocol definition, ranging from 1 to 65,534." ::= { cinPortConfigEntry 4 } cinPortConfigInternalPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The internal port number specified for this port protocol definition, ranging from 1 to 65,534." ::= { cinPortConfigEntry 5 } cinPortConfigEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of this port protocol definition." ::= { cinPortConfigEntry 6 } cinPortConfigDirection OBJECT-TYPE SYNTAX INTEGER { incoming(1), outgoing(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The traffic direction specified for this port protocol definition." ::= { cinPortConfigEntry 7 } -- ******************************************************************************** -- SNMP (Ers) Configuration -- ******************************************************************************** configurationManagement OBJECT IDENTIFIER ::= { configureSP 15 } saveConfigurationToChassis OBJECT-TYPE SYNTAX INTEGER { compressedFormat(1), legacyFormat(2) -- deprecated } ACCESS read-write STATUS mandatory DESCRIPTION "Save the configuration settings from the AMM to the chassis. This operation may take several seconds. The input values for the SET command when AMM is installed in BladeCenter and BladeCenter T are: 1: Save the configuration settings in compressed(AMM) format. 2: Save the configuration settings in legacy(MM) format. This option has been deprecated. other: Invalid. The input values for the SET command when AMM is installed in BladeCenter H and BladeCenter HT are: 1: Save the configuration settings in compressed(AMM) format. other: Invalid. NOTE: This MIB object is for AMM only and the value returned for the GET command is meaningless." ::= { configurationManagement 1 } restoreConfigurationFromChassis OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Restore the configuration settings to the AMM from the BladeCenter chassis. NOTE: This MIB object is for AMM only and the value returned for the GET command is meaningless." ::= { configurationManagement 2 } autoReadConfigInNewChassis OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The AMM will automatically read configuration settings from the midplane every time the AMM is inserted into a new chassis. NOTE: This MIB object is for AMM only." ::= { configurationManagement 3 } -- ************************************************************************ -- BladeCenter T System Management -- ************************************************************************ -- ************************************************************************ telcoAlarmReq OBJECT IDENTIFIER ::= { telcoManagement 1 } -- ************************************************************************ -- BladeCenter T Set A Software Alarm -- ************************************************************************ telcoAlarmSet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Create a software alarm. An input octet string consists of the alarm severity level and the alarm description (40 bytes max). The following severity levels are valid : CRT Critical MJR Major MNR Minor NOTE 1: The level (e.g. MJR) and alarm description string must be separated by a blank, otherwise, a badValue error will be returned. NOTE 2: Value returned for the GET command is meaningless for this MIB object. NOTE 3: This MIB object is for BladeCenter T only." ::= { telcoAlarmReq 1 } -- ************************************************************************ -- BladeCenter T Ack an Alarm -- ************************************************************************ telcoAlarmAck OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Acknowledge an alarm. An input octet string consists of the alarm key ID expressed as 'mmm:ggg:iii:aaa:sss' where: m : Module ID value of decimal digits(1-255) or blank space(s) for leading zero(s) g : Gen ID value of decimal digits(1-255) or blank space(s) for leading zero(s) i : GenInfo ID value of decimal digits(1-255) or blank space(s) for leading zero(s) a : Alarm ID value of decimal digits(1-255) or blank space(s) for leading zero(s) s : Alarm severity value of decimal digits(1-255) or blank space(s) for leading zero(s) NOTE 1: Value returned for the GET command is meaningless for this MIB object. NOTE 2: This MIB object is for BladeCenter T only." ::= { telcoAlarmReq 2 } -- ************************************************************************ -- BladeCenter T Clear an Alarm -- ************************************************************************ telcoAlarmClear OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Clear an active alarm. An input octet string consists of the alarm key ID expressed as 'mmm:ggg:iii:aaa:sss' where: m : Module ID value of decimal digits(1-255) or blank space(s) for leading zero(s) g : Gen ID value of decimal digits(1-255) or blank space(s) for leading zero(s) i : GenInfo ID value of decimal digits(1-255) or blank space(s) for leading zero(s) a : Alarm ID value of decimal digits(1-255) or blank space(s) for leading zero(s) s : Alarm severity value of decimal digits(1-255) or blank space(s) for leading zero(s) NOTE1 : Value returned for the GET command is meaningless for this MIB object. NOTE 2: This MIB object is for BladeCenter T only." ::= { telcoAlarmReq 3 } -- ************************************************************************ -- ************************************************************************ -- BladeCenter HT Hardware Operation Management -- ************************************************************************ telcoHWManagement OBJECT IDENTIFIER ::= { telcoManagement 3 } -- ******************************************************************************** -- Telco Alarm Panel Power ON/OFF operation -- ******************************************************************************** tappowerReq OBJECT IDENTIFIER ::= { telcoHWManagement 1 } tappoweronoff OBJECT-TYPE SYNTAX INTEGER { poweroff(0), poweron(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Telco Alarm Panel power on or power off. If powering off a currently powered on Telco Alarm Panel, then all LEDs of this request card will be reset to OFF and the Safely Remove LED will be turned ON to indicate the card is safe for removal. NOTE: This MIB object is for BladeCenter HT only. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { tappowerReq 1} -- ******************************************************************************** -- Network Clock Power ON/OFF operation -- ******************************************************************************** ncReq OBJECT IDENTIFIER ::= { telcoHWManagement 2 } -- ******************************************************************************** -- Network Clock Cards -- **************************************************************************** ncReqTable OBJECT-TYPE SYNTAX SEQUENCE OF NcReqEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Table of the Network Clock Module Operations. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { ncReq 1 } ncReqEntry OBJECT-TYPE SYNTAX NcReqEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Network Clock Module Power ON/OFF entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." INDEX { ncReqIndex } ::= { ncReqTable 1 } NcReqEntry ::= SEQUENCE { ncReqIndex INTEGER, ncReqBayNumber INTEGER, ncReqPoweronoff INTEGER } ncReqIndex OBJECT-TYPE SYNTAX INTEGER (0..128) ACCESS read-only STATUS deprecated DESCRIPTION "Network Clock Module Request index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { ncReqEntry 1 } ncReqBayNumber OBJECT-TYPE SYNTAX INTEGER { networkclock1(1), networkclock2(2) } ACCESS read-only STATUS deprecated DESCRIPTION "Network Clock Module Request Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only." ::= { ncReqEntry 2 } ncReqPoweronoff OBJECT-TYPE SYNTAX INTEGER { poweroff(0), poweron(1) } ACCESS read-write STATUS deprecated DESCRIPTION "Request to power on/off for the specified Network Clock Module. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { ncReqEntry 3 } -- ************************************************************************ -- BladeCenter T OEM grouping -- ************************************************************************ telcoOEM OBJECT IDENTIFIER ::= { telcoManagement 127 } telcoOEMs OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A bitmap of information about the contents of this subtree. The bitmap is a variable length string containing a list of 1's and 0's. Every bit that is set to 1 has a corresponding subtree entry that is supported in firmware, while a 0 means that the subtree entry is unavailable. NOTE: This MIB object is for BladeCenter T only." ::= { telcoOEM 1 } -- ******************************************************************************** -- Restart Control -- ******************************************************************************** restartSPImmediately OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Restart the MM immediately. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { restartReset 4 } restartStandbyMM OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Restarts the Standby MM from the Primary MM. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This mib object is only applicable to systems with a standby MM." ::= { restartReset 5} switchOverRedundantMM OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Switch over to the redundant Management Module. The failover will not occur if the standby or primary MM is in flashing mode. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This mib object is only applicable to systems with a redundant MM." ::= { restartReset 7 } resetSPConfigAndRestart OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Will cause all the MM information to be reset to it's initial factory defaults (all previous configuration information is lost) and the MM will be re-started. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { restartReset 20 } resetSPConfigAndRestartSaveLogs OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Will cause all the MM information to be reset to it's initial factory defaults (all previous configuration information is lost) and the MM will be re-started. The logs will be saved. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { restartReset 21 } -- ******************************************************************************** -- processorBlade -- ******************************************************************************** --This group of objects provides information specific to blades processorBlade OBJECT IDENTIFIER ::= { blades 1 } -- ******************************************************************************** -- Media and I/O -- ******************************************************************************** bladeMediaTrayBladeId OBJECT-TYPE SYNTAX INTEGER { managementModule(0), blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-write STATUS mandatory DESCRIPTION "Allocate the media tray to a blade of a BladeCenter system. On a get command, a blade ID of 0x00 means that no blade is currently using the device. A set command cannot allocate the media tray to the management module. NOTE: A blade cannot be allocated to the media tray if the value of OID remoteMediaTraySwitchEnable of the blade is disabled." ::= { processorBlade 1 } bladeKVMBladeId OBJECT-TYPE SYNTAX INTEGER { managementModule(0), blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-write STATUS mandatory DESCRIPTION "Allocate the keyboard, video, and mouse ports (KVM) to a blade of a blade runner system. On a get command, a blade ID of 0x00 means that no blade is currently using the devices. A set command cannot allocate the KVM to the management module." ::= { processorBlade 2 } -- ******************************************************************************** -- Blade boot sequence -- ******************************************************************************** bladeBootSequenceTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeBootSequenceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade boot sequence information. Contains the boot sequence information for each blade." ::= { processorBlade 3 } bladeBootSequenceEntry OBJECT-TYPE SYNTAX BladeBootSequenceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Boot sequence entry" INDEX { bootSequenceIndex } ::= { bladeBootSequenceTable 1 } BladeBootSequenceEntry ::= SEQUENCE { bootSequenceIndex INTEGER, bootSequenceBladeId INTEGER, bootSequenceBladeExists INTEGER, bootSequenceBladePowerState INTEGER, bootSequenceBladeHealthState INTEGER, bootSequenceBladeName OCTET STRING, bootSequence1 INTEGER, bootSequence2 INTEGER, bootSequence3 INTEGER, bootSequence4 INTEGER } bootSequenceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade boot sequence index." ::= { bladeBootSequenceEntry 1 } bootSequenceBladeId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { bladeBootSequenceEntry 2 } bootSequenceBladeExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the server blade specified exists or not." ::= { bladeBootSequenceEntry 3 } bootSequenceBladePowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), standby(3), hibernate(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the power state of the blade specified." ::= { bladeBootSequenceEntry 4 } bootSequenceBladeHealthState OBJECT-TYPE SYNTAX INTEGER { unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11) } ACCESS read-only STATUS mandatory DESCRIPTION "The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade." ::= { bladeBootSequenceEntry 5 } bootSequenceBladeName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the blade as a null terminated string." ::= { bladeBootSequenceEntry 6 } bootSequence1 OBJECT-TYPE SYNTAX INTEGER { noneSpecified(0), floppy(1), cdrom(2), hardDrive0(3), hardDrive1(4), hardDrive2(5), hardDrive3(6), networkBoot(7), iscsi(8), iscsiCritical(9), hardDrive4(10), usbModularFlashDrive(11), hypervisor(12), uefi(13), legacyonly(14), notAvailable(255) } ACCESS read-write STATUS mandatory DESCRIPTION "The boot device for this blade boot sequence. Note that some types of blades don't support floppy disk drive. It is recommended that all boot sequence 1,2 3, and 4 be configured starting from boot sequence 1. If there is any duplication of the configured boot sequence and the current configuration, the two boot sequence will be swapped. For an example: the current boot sequence is 1=HD0, 2=CD, 3=FD, 4=HD1 If the user wants to configure 1=FD which is a duplication of 3 then the new boot sequence will be: 1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped) Not all hard drives are available on all blade configurations. The 'Iscsi critical' option has a special meaning: the blade tries to find an iscsi boot device and if it does not it keeps trying forever." ::= { bladeBootSequenceEntry 7 } bootSequence2 OBJECT-TYPE SYNTAX INTEGER { noneSpecified(0), floppy(1), cdrom(2), hardDrive0(3), hardDrive1(4), hardDrive2(5), hardDrive3(6), networkBoot(7), iscsi(8), iscsiCritical(9), hardDrive4(10), usbModularFlashDrive(11), hypervisor(12), uefi(13), legacyonly(14), notAvailable(255) } ACCESS read-write STATUS mandatory DESCRIPTION "The boot device for this blade boot sequence. Note that some types of blades don't support floppy disk drive. It is recommended that all boot sequence 1,2 3, and 4 be configured starting from boot sequence 1. If there is any duplication of the configured boot sequence and the current configuration, the two boot sequence will be swapped. For an example: the current boot sequence is 1=HD0, 2=CD, 3=FD, 4=HD1 If the user wants to configure 1=FD which is a duplication of 3 then the new boot sequence will be: 1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped) Not all hard drives are available on all blade configurations. The 'Iscsi critical' option has a special meaning: the blade tries to find an iscsi boot device and if it does not it keeps trying forever." ::= { bladeBootSequenceEntry 8 } bootSequence3 OBJECT-TYPE SYNTAX INTEGER { noneSpecified(0), floppy(1), cdrom(2), hardDrive0(3), hardDrive1(4), hardDrive2(5), hardDrive3(6), networkBoot(7), iscsi(8), iscsiCritical(9), hardDrive4(10), usbModularFlashDrive(11), hypervisor(12), uefi(13), legacyonly(14), notAvailable(255) } ACCESS read-write STATUS mandatory DESCRIPTION "The boot device for this blade boot sequence. Note that some types of blades don't support floppy disk drive. It is recommended that all boot sequence 1,2 3, and 4 be configured starting from boot sequence 1. If there is any duplication of the configured boot sequence and the current configuration, the two boot sequence will be swapped. For an example: the current boot sequence is 1=HD0, 2=CD, 3=FD, 4=HD1 If the user wants to configure 1=FD which is a duplication of 3 then the new boot sequence will be: 1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped) Not all hard drives are available on all blade configurations. The 'Iscsi critical' option has a special meaning: the blade tries to find an iscsi boot device and if it does not it keeps trying forever." ::= { bladeBootSequenceEntry 9 } bootSequence4 OBJECT-TYPE SYNTAX INTEGER { noneSpecified(0), floppy(1), cdrom(2), hardDrive0(3), hardDrive1(4), hardDrive2(5), hardDrive3(6), networkBoot(7), iscsi(8), iscsiCritical(9), hardDrive4(10), usbModularFlashDrive(11), hypervisor(12), uefi(13), legacyonly(14), notAvailable(255) } ACCESS read-write STATUS mandatory DESCRIPTION "The boot device for this blade boot sequence. Note that some types of blades don't support floppy disk drive. It is recommended that all boot sequence 1,2 3, and 4 be configured starting from boot sequence 1. If there is any duplication of the configured boot sequence and the current configuration, the two boot sequence will be swapped. For an example: the current boot sequence is 1=HD0, 2=CD, 3=FD, 4=HD1 If the user wants to configure 1=FD which is a duplication of 3 then the new boot sequence will be: 1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped) Not all hard drives are available on all blade configurations. The 'Iscsi critical' option has a special meaning: the blade tries to find an iscsi boot device and if it does not it keeps trying forever." ::= { bladeBootSequenceEntry 10 } -- ******************************************************************************** -- Blade local control -- ******************************************************************************** bladeRemoteControl OBJECT IDENTIFIER ::= { processorBlade 4 } -- remote blade control bladeRemoteControlTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeRemoteControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade remote power control information. Contains power on/off enablement status for each blade." ::= { bladeRemoteControl 1 } bladeRemoteControlEntry OBJECT-TYPE SYNTAX BladeRemoteControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Remote power control entry" INDEX { remoteControlIndex } ::= { bladeRemoteControlTable 1 } BladeRemoteControlEntry ::= SEQUENCE { remoteControlIndex INTEGER, remoteControlBladeId INTEGER, remoteControlBladeExists INTEGER, remoteControlBladePowerState INTEGER, remoteControlBladeHealthState INTEGER, remoteControlBladeName OCTET STRING, remotePowerControlEnable INTEGER, remoteMediaTrayControlEnable INTEGER, remoteKVMControlEnable INTEGER, remoteWakeOnLanControlEnable INTEGER, remoteMediaTraySwitchEnable INTEGER } remoteControlIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade remote power control index." ::= { bladeRemoteControlEntry 1 } remoteControlBladeId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { bladeRemoteControlEntry 2 } remoteControlBladeExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the server blade specified exists or not." ::= { bladeRemoteControlEntry 3 } remoteControlBladePowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), standby(3), hibernate(4), unknown(255) } ACCESS read-only STATUS mandatory DESCRIPTION "The power state for blade. 0 = off, 1 = on, 3 = standby, 4 = hibernate, 255 = unknown." ::= { bladeRemoteControlEntry 4 } remoteControlBladeHealthState OBJECT-TYPE SYNTAX INTEGER { unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11) } ACCESS read-only STATUS mandatory DESCRIPTION "The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade." ::= { bladeRemoteControlEntry 5 } remoteControlBladeName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the blade as a null terminated string." ::= { bladeRemoteControlEntry 6 } remotePowerControlEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Blade remote power control enablement status." ::= { bladeRemoteControlEntry 7 } remoteMediaTrayControlEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Blade media tray enablement status." ::= { bladeRemoteControlEntry 8 } remoteKVMControlEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Blade KVM enablement status. Note that some types of blades don't support KVM" ::= { bladeRemoteControlEntry 9 } remoteWakeOnLanControlEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1), notApplicable(255) } ACCESS read-write STATUS mandatory DESCRIPTION "Blade Wake On LAN enablement status. If WOL is not supported by the blade, it displays 'notApplicable' and WOL can not be enabled or disabled." ::= { bladeRemoteControlEntry 10 } remoteMediaTraySwitchEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Blade Remote Media Tray Switch enablement status. If the remote disk feature is disabled, this OID cannot be set." ::= { bladeRemoteControlEntry 11 } bladePolicy OBJECT IDENTIFIER ::= { bladeRemoteControl 2} -- global blade remote control policy bladePolicyPowerControlEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Blade remote power control enablement status policy." ::= { bladePolicy 1 } bladePolicyMediaTrayControlEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Blade media tray enablement status policy." ::= { bladePolicy 2 } bladePolicyKVMControlEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Blade KVM enablement status policy. Note that some types of blades don't support KVM." ::= { bladePolicy 3 } bladePolicyWakeOnLanControlEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1), notApplicable(255) } ACCESS read-write STATUS mandatory DESCRIPTION "Blade Wake On LAN enablement status policy. The notApplicable(255) enumeration is not valid for SET operations. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { bladePolicy 4 } bladePolicyMediaTraySwitchEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Blade Remote Media Tray Switch enablement status policy. If the remote disk feature is disabled, this OID cannot be set." ::= { bladePolicy 5 } bladePolicyMultipleRemoteVideoEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Blade multiple remote video sessions enablement status policy. A maximum users can access the video of the same blade from remote console when set to enabled. If it is disabled, only one user can access the video from remote control." ::= { bladePolicy 6 } bladePolicyAutoPowerOn OBJECT-TYPE SYNTAX INTEGER { restore(1), auto(2), manual(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Blade auto-power on policy. - restore: all blades will be powered on which were previously on. - auto: all blades will automatically be powered on when power is applied to the chassis. - manual: all blades will be left off until manually powered on by the user." ::= { bladePolicy 7 } bladePolicyDisconnectionMode OBJECT-TYPE SYNTAX INTEGER { noDisconnection(0), forceDisconnection(1), accessRequest(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Blade disconnection mode. - noDisconnection: If the blade is already serving a maximum number of users, the requester can't get connection - forcedisconnection: If the blade is already serving a maximum number of users, the requester can disconnect any connected user. - accessRequest: If the blade is already serving an user, this one will get an access request from the requester." ::= { bladePolicy 8 } bladePolicySessionTimeOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Client session time out in minutes. If there is no remote presence activity, after that time, the session will be closed authomatically." ::= { bladePolicy 9 } bladePolicyRequestTimeOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Client connection request time out in seconds. In case of single session mode, if the requested user does not respond within this timeout, the user request will be accepted authomatically." ::= { bladePolicy 10 } bladePolicyRetryTimeOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Client connection retry time out in seconds. It is possible that the current blade access is negotiated by other 2 clients. If the third comes it will need to wait and retry to connect after a while." ::= { bladePolicy 11 } bladePolicySessionLostTimeOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Client session lost in minutes. Amount of time before session closes due to loss of session, and user may regain control. This may happen if for example the client machine loses a network connection." ::= { bladePolicy 12 } -- ******************************************************************************** -- Blade system health state params -- ******************************************************************************** bladeMonitors OBJECT IDENTIFIER ::= { processorBlade 5 } bladeSystemStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeSystemStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade status information." ::= { bladeMonitors 1 } bladeSystemStatusEntry OBJECT-TYPE SYNTAX BladeSystemStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade system status entry" INDEX { bladeStatusIndex } ::= { bladeSystemStatusTable 1 } BladeSystemStatusEntry ::= SEQUENCE { bladeStatusIndex INTEGER, bladeId INTEGER, bladeExists INTEGER, bladePowerState INTEGER, bladeHealthState INTEGER, bladeName OCTET STRING, bladeRemotePowerEnable INTEGER, bladeRemoteMediaTrayEnable INTEGER, bladeRemoteKVMEnable INTEGER, bladeConnectionType INTEGER, bladeOwnsKVM INTEGER, bladeOwnsMediaTray INTEGER, bladeRemoteWakeOnLanEnable INTEGER, bladeServerExpansion INTEGER, bladeWidth INTEGER, bladeSupportCapacityOnDemand INTEGER, -- deprecated bladeServerExpansion2 INTEGER, bladecKVMStatus INTEGER, bladeConnectionType2 INTEGER, bladeConnectionType3 INTEGER, bladeConnectionType4 INTEGER, bladeConnectionType5 INTEGER, bladeHighSpeedConnectionType INTEGER, bladeIOCompatibility OCTET STRING, bladeInventoryReady INTEGER } bladeStatusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade system status index." ::= { bladeSystemStatusEntry 1 } bladeId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { bladeSystemStatusEntry 2 } bladeExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the server blade specified exists or not." ::= { bladeSystemStatusEntry 3 } bladePowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), standby(3), hibernate(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the power state of the blade specified." ::= { bladeSystemStatusEntry 4 } bladeHealthState OBJECT-TYPE SYNTAX INTEGER { unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11) } ACCESS read-only STATUS mandatory DESCRIPTION "The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade." ::= { bladeSystemStatusEntry 5 } bladeName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the blade as a null terminated string." ::= { bladeSystemStatusEntry 6 } bladeRemotePowerEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Remote power state for the blade. 0x01 indicates enabled." ::= { bladeSystemStatusEntry 7 } bladeRemoteMediaTrayEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Remote Media Tray state for the blade. 0x01 indicates enabled." ::= { bladeSystemStatusEntry 8 } bladeRemoteKVMEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Remote keyboard/video/monitor state for the blade. 0x01 indicates enabled. Note that some types of blades don't support KVM" ::= { bladeSystemStatusEntry 9 } bladeConnectionType OBJECT-TYPE SYNTAX INTEGER { none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Connection type of the expansion card number one." ::= { bladeSystemStatusEntry 10 } bladeOwnsKVM OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the MM owns the KVM. 0 = false, 1 = true. Note that some types of blades don't support KVM" ::= { bladeSystemStatusEntry 11 } bladeOwnsMediaTray OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the blade owns the Media Tray. 0 = false, 1 = true." ::= { bladeSystemStatusEntry 12 } bladeRemoteWakeOnLanEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Remote wake on LAN state for the blade. 0x01 indicates enabled." ::= { bladeSystemStatusEntry 13 } bladeServerExpansion OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This shows whether this blade has an expansion board attached. A yes column indicates that an expansion board is installed for this blade." ::= { bladeSystemStatusEntry 14 } bladeWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The width of the blade including any supplement blade attached to it" ::= { bladeSystemStatusEntry 15 } bladeSupportCapacityOnDemand OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS deprecated DESCRIPTION "This shows whether this blade support Capacity On Demand. NOTE: This Mib object is deprecated and no longer supported." ::= { bladeSystemStatusEntry 16 } bladeServerExpansion2 OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This shows whether this blade has an expansion board attached. A yes column indicates that an expansion board is installed for this blade." ::= { bladeSystemStatusEntry 17 } bladecKVMStatus OBJECT-TYPE SYNTAX INTEGER { notPresent(0), notReady(1), ready(2), active(3), disabled(4), notAvailable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "This shows whether this blade has a concurrent keyboard, video, and mouse (cKVM) card installed and the status of cKVM on the blade. Not present: A cKVM card is not installed. Not ready: A cKVM card is installed but is not functional. Ready: A cKVM card is installed and is functional, with no cKVM session in progress. Active: A cKVM card is installed and is functional, with a cKVM session currently in progress. Disabled: A cKVM card is not enabled on this blade. Not available: A cKVM card is installed but the status is not available." ::= { bladeSystemStatusEntry 21 } bladeConnectionType2 OBJECT-TYPE SYNTAX INTEGER { none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Connection type of the expansion card number 2." ::= { bladeSystemStatusEntry 22 } bladeConnectionType3 OBJECT-TYPE SYNTAX INTEGER { none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Connection type of the expansion card number 3." ::= { bladeSystemStatusEntry 23 } bladeConnectionType4 OBJECT-TYPE SYNTAX INTEGER { none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Connection type of the expansion card number 4." ::= { bladeSystemStatusEntry 24 } bladeConnectionType5 OBJECT-TYPE SYNTAX INTEGER { none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Connection type of the expansion card number 5." ::= { bladeSystemStatusEntry 25 } bladeHighSpeedConnectionType OBJECT-TYPE SYNTAX INTEGER { none(0), ethernet(1), fiber(2), serial(3), opticalPassThrough(4), infiniband(5), iSCSI(6), infinibandPassThrough(7) } ACCESS read-only STATUS mandatory DESCRIPTION "Connection type of the high speed expansion card number 1." ::= { bladeSystemStatusEntry 41 } bladeIOCompatibility OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "I/O compatibility status for the blade. The possible values and their meanings are as follows: unknown: This indicates a communication error for the blade. ok: This is the normal (good) case where the blade and the corresponding I/O modules it is internally wired to have no compatibility issues. noIOMs: This means there are no I/O modules in any of the corresponding I/O module bays this blade is internally wired to. attention: This indicates that one or more of the corresponding I/O modules are in communication error. mismatch: This indicates one of the following cases: Fabric types are incompatible An unknown I/O module type An unknown fabric type on the blade" ::= { bladeSystemStatusEntry 51 } bladeInventoryReady OBJECT-TYPE SYNTAX INTEGER { notReady(0), ready(1) } ACCESS read-only STATUS mandatory DESCRIPTION "When a blade management controller or the AMM is reset, the blade inventory data is refreshed in the AMM database. This includes items like IBM VPD (e.g. - serial number, UUID) and MAC address information. Applications need to know when this information has been populated on the AMM before they begin to query it using SNMP or other means. This simple flag object will return a ready or notReady indication for each blade regarding the status of this information. Notes: For blades that are experiencing a 'communication failure' or 'initialization failure' condition, this object will continue to indicate notReady until the condition is resolved. Therefore, any application that polls this object should also incorporate a timeout period. As of AMM release v5.3, a 10 minute timeout seems to be a minimum suggested polling period." ::= { bladeSystemStatusEntry 52 } bladeHealthSummaryTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeHealthSummaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade health summary information. Contains information about the overall blade health status." ::= { bladeMonitors 2 } bladeHealthSummaryEntry OBJECT-TYPE SYNTAX BladeHealthSummaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade health summary entry" INDEX { bladeHealthSummaryIndex } ::= { bladeHealthSummaryTable 1 } BladeHealthSummaryEntry ::= SEQUENCE { bladeHealthSummaryIndex INTEGER, bladeHealthSummaryBladeId INTEGER, bladeHealthSummarySeverity OCTET STRING, bladeHealthSummaryDescription OCTET STRING, bladeHealthSummaryDateTime OCTET STRING } bladeHealthSummaryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade health summary index." ::= { bladeHealthSummaryEntry 1 } bladeHealthSummaryBladeId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { bladeHealthSummaryEntry 2 } bladeHealthSummarySeverity OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "System health summary severity." ::= { bladeHealthSummaryEntry 3 } bladeHealthSummaryDescription OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "System health summary description." ::= { bladeHealthSummaryEntry 4 } bladeHealthSummaryDateTime OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "System health summary date time." ::= { bladeHealthSummaryEntry 5 } bladeTemperaturesTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeTemperaturesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade temperatures information." ::= { bladeMonitors 3 } bladeTemperaturesEntry OBJECT-TYPE SYNTAX BladeTemperaturesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade temperatures table entry" INDEX { temperatureIndex } ::= { bladeTemperaturesTable 1 } BladeTemperaturesEntry ::= SEQUENCE { temperatureIndex INTEGER, temperatureBladeId INTEGER, temperatureBladeExists INTEGER, temperatureBladePowerState INTEGER, temperatureBladeName OCTET STRING, temperatureCPU1 OCTET STRING, temperatureCPU2 OCTET STRING, temperatureCPU3 OCTET STRING, temperatureCPU4 OCTET STRING, temperatureDASD1 OCTET STRING, bladeSensorTempCapability INTEGER, bladeSensor1Temp OCTET STRING, bladeSensor2Temp OCTET STRING, bladeSensor3Temp OCTET STRING, bladeSensor4Temp OCTET STRING, bladeSensor5Temp OCTET STRING, bladeSensor6Temp OCTET STRING, bladeSensor7Temp OCTET STRING, bladeSensor8Temp OCTET STRING, bladeSensor9Temp OCTET STRING } temperatureIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade temperatures table index." ::= { bladeTemperaturesEntry 1 } temperatureBladeId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { bladeTemperaturesEntry 2 } temperatureBladeExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the server blade specified exists or not." ::= { bladeTemperaturesEntry 3 } temperatureBladePowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), standby(3), hibernate(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the power state of the blade specified." ::= { bladeTemperaturesEntry 4 } temperatureBladeName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the blade as a null terminated string." ::= { bladeTemperaturesEntry 5 } temperatureCPU1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperaturesEntry 6 } temperatureCPU2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperaturesEntry 7 } temperatureCPU3 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperaturesEntry 8 } temperatureCPU4 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperaturesEntry 9 } temperatureDASD1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade DASD temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperaturesEntry 10 } bladeSensorTempCapability OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the server blade is IPMI capable or not." ::= { bladeTemperaturesEntry 11 } bladeSensor1Temp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperaturesEntry 12 } bladeSensor2Temp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperaturesEntry 13 } bladeSensor3Temp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperaturesEntry 14 } bladeSensor4Temp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperaturesEntry 15 } bladeSensor5Temp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperaturesEntry 16 } bladeSensor6Temp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperaturesEntry 17 } bladeSensor7Temp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperaturesEntry 18 } bladeSensor8Temp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperaturesEntry 19 } bladeSensor9Temp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Temperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperaturesEntry 20 } bladeTemperatureThresholdsTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeTemperatureThresholdsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade temperature thresholds information." ::= { bladeMonitors 4 } bladeTemperatureThresholdsEntry OBJECT-TYPE SYNTAX BladeTemperatureThresholdsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade temperature thresholds table entry" INDEX { temperatureThresholdIndex } ::= { bladeTemperatureThresholdsTable 1 } BladeTemperatureThresholdsEntry ::= SEQUENCE { temperatureThresholdIndex INTEGER, temperatureThresholdBladeId INTEGER, temperatureThresholdBladeExists INTEGER, temperatureThresholdBladePowerState INTEGER, temperatureThresholdBladeName OCTET STRING, temperatureCPU1HardShutdown OCTET STRING, temperatureCPU1Warning OCTET STRING, temperatureCPU1WarningReset OCTET STRING, temperatureCPU2HardShutdown OCTET STRING, temperatureCPU2Warning OCTET STRING, temperatureCPU2WarningReset OCTET STRING, temperatureCPU3HardShutdown OCTET STRING, temperatureCPU3Warning OCTET STRING, temperatureCPU3WarningReset OCTET STRING, temperatureCPU4HardShutdown OCTET STRING, temperatureCPU4Warning OCTET STRING, temperatureCPU4WarningReset OCTET STRING, temperatureDASD1HardShutdown OCTET STRING, temperatureDASD1Warning OCTET STRING, temperatureDASD1WarningReset OCTET STRING, bladeTempThresholdSensorCapability INTEGER, temperatureSensor1HardShutdown OCTET STRING, temperatureSensor1Warning OCTET STRING, temperatureSensor1WarningReset OCTET STRING, temperatureSensor2HardShutdown OCTET STRING, temperatureSensor2Warning OCTET STRING, temperatureSensor2WarningReset OCTET STRING, temperatureSensor3HardShutdown OCTET STRING, temperatureSensor3Warning OCTET STRING, temperatureSensor3WarningReset OCTET STRING, temperatureSensor4HardShutdown OCTET STRING, temperatureSensor4Warning OCTET STRING, temperatureSensor4WarningReset OCTET STRING, temperatureSensor5HardShutdown OCTET STRING, temperatureSensor5Warning OCTET STRING, temperatureSensor5WarningReset OCTET STRING, temperatureSensor6HardShutdown OCTET STRING, temperatureSensor6Warning OCTET STRING, temperatureSensor6WarningReset OCTET STRING, temperatureSensor7HardShutdown OCTET STRING, temperatureSensor7Warning OCTET STRING, temperatureSensor7WarningReset OCTET STRING, temperatureSensor8HardShutdown OCTET STRING, temperatureSensor8Warning OCTET STRING, temperatureSensor8WarningReset OCTET STRING, temperatureSensor9HardShutdown OCTET STRING, temperatureSensor9Warning OCTET STRING, temperatureSensor9WarningReset OCTET STRING } temperatureThresholdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade temperature threshold table index." ::= { bladeTemperatureThresholdsEntry 1 } temperatureThresholdBladeId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { bladeTemperatureThresholdsEntry 2 } temperatureThresholdBladeExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the server blade specified exists or not." ::= { bladeTemperatureThresholdsEntry 3 } temperatureThresholdBladePowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), standby(3), hibernate(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the power state of the blade specified." ::= { bladeTemperatureThresholdsEntry 4 } temperatureThresholdBladeName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the blade as a null terminated string." ::= { bladeTemperatureThresholdsEntry 5 } temperatureCPU1HardShutdown OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 6 } temperatureCPU1Warning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 7 } temperatureCPU1WarningReset OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 8 } temperatureCPU2HardShutdown OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 9 } temperatureCPU2Warning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 10 } temperatureCPU2WarningReset OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 11 } temperatureCPU3HardShutdown OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 12 } temperatureCPU3Warning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 13 } temperatureCPU3WarningReset OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 14 } temperatureCPU4HardShutdown OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediately. If enabled, a critical alert/event will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 15 } temperatureCPU4Warning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 16 } temperatureCPU4WarningReset OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been created then the alert/event will be reset. An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 17 } temperatureDASD1HardShutdown OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade DASD hard shutdown temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 18 } temperatureDASD1Warning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade DASD warning temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 19 } temperatureDASD1WarningReset OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade DASD warning reset temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 20 } bladeTempThresholdSensorCapability OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the server blade is IPMI capable or not." ::= { bladeTemperatureThresholdsEntry 21 } temperatureSensor1HardShutdown OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 22 } temperatureSensor1Warning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 23 } temperatureSensor1WarningReset OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 24 } temperatureSensor2HardShutdown OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 25 } temperatureSensor2Warning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 26 } temperatureSensor2WarningReset OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 27 } temperatureSensor3HardShutdown OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 28 } temperatureSensor3Warning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 29 } temperatureSensor3WarningReset OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 30 } temperatureSensor4HardShutdown OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 31 } temperatureSensor4Warning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 32 } temperatureSensor4WarningReset OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 33 } temperatureSensor5HardShutdown OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 34 } temperatureSensor5Warning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 35 } temperatureSensor5WarningReset OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 36 } temperatureSensor6HardShutdown OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 37 } temperatureSensor6Warning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 38 } temperatureSensor6WarningReset OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 39 } temperatureSensor7HardShutdown OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 40 } temperatureSensor7Warning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 41 } temperatureSensor7WarningReset OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 42 } temperatureSensor8HardShutdown OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 43 } temperatureSensor8Warning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 44 } temperatureSensor8WarningReset OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 45 } temperatureSensor9HardShutdown OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 46 } temperatureSensor9Warning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 47 } temperatureSensor9WarningReset OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for positive) d is a decimal digit or blank space for leading zeroes. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Temperature' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeTemperatureThresholdsEntry 48 } bladeVoltagesTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeVoltagesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade voltages information." ::= { bladeMonitors 5 } bladeVoltagesEntry OBJECT-TYPE SYNTAX BladeVoltagesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade voltages table entry" INDEX { voltageIndex } ::= { bladeVoltagesTable 1 } BladeVoltagesEntry ::= SEQUENCE { voltageIndex INTEGER, voltageBladeId INTEGER, voltageBladeExists INTEGER, voltageBladePowerState INTEGER, voltageBladeName OCTET STRING, bladePlus5Volt OCTET STRING, bladePlus3pt3Volt OCTET STRING, bladePlus12Volt OCTET STRING, bladePlus2pt5Volt OCTET STRING, bladePlus1pt5Volt OCTET STRING, bladePlus1pt25Volt OCTET STRING, bladeVRM1Volt OCTET STRING, bladeSensorVoltCapability INTEGER, bladeSensor1Volt OCTET STRING, bladeSensor2Volt OCTET STRING, bladeSensor3Volt OCTET STRING, bladeSensor4Volt OCTET STRING, bladeSensor5Volt OCTET STRING, bladeSensor6Volt OCTET STRING, bladeSensor7Volt OCTET STRING, bladeSensor8Volt OCTET STRING, bladeSensor9Volt OCTET STRING, bladeSensor10Volt OCTET STRING, bladeSensor11Volt OCTET STRING, bladeSensor12Volt OCTET STRING, bladeSensor13Volt OCTET STRING, bladeSensor14Volt OCTET STRING, bladeSensor15Volt OCTET STRING, bladeSensor16Volt OCTET STRING, bladeSensor17Volt OCTET STRING, bladeSensor18Volt OCTET STRING, bladeSensor19Volt OCTET STRING, bladeSensor20Volt OCTET STRING, bladeSensor21Volt OCTET STRING, bladeSensor22Volt OCTET STRING, bladeSensor23Volt OCTET STRING, bladeSensor24Volt OCTET STRING, bladeSensor25Volt OCTET STRING, bladeSensor26Volt OCTET STRING, bladeSensor27Volt OCTET STRING, bladeSensor28Volt OCTET STRING, bladeSensor29Volt OCTET STRING, bladeSensor30Volt OCTET STRING } voltageIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade voltages table index." ::= { bladeVoltagesEntry 1 } voltageBladeId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { bladeVoltagesEntry 2 } voltageBladeExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the server blade specified exists or not." ::= { bladeVoltagesEntry 3 } voltageBladePowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), standby(3), hibernate(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the power state of the blade specified." ::= { bladeVoltagesEntry 4 } voltageBladeName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the blade as a null terminated string." ::= { bladeVoltagesEntry 5 } bladePlus5Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "+5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 6 } bladePlus3pt3Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "+3.3 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 7 } bladePlus12Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "+12 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 8 } bladePlus2pt5Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "+2.5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 10 } bladePlus1pt5Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "+1.5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 11 } bladePlus1pt25Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "+1.25 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 12 } bladeVRM1Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "VRM 1 voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 13 } bladeSensorVoltCapability OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the server blade is IPMI capable or not." ::= { bladeVoltagesEntry 14 } bladeSensor1Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 15 } bladeSensor2Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 16 } bladeSensor3Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 17 } bladeSensor4Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 18 } bladeSensor5Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 19 } bladeSensor6Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 20 } bladeSensor7Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 21 } bladeSensor8Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 22 } bladeSensor9Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 23 } bladeSensor10Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 24 } bladeSensor11Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 25 } bladeSensor12Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 26 } bladeSensor13Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 27 } bladeSensor14Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 28 } bladeSensor15Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 29 } bladeSensor16Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 30 } bladeSensor17Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 31 } bladeSensor18Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 32 } bladeSensor19Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 33 } bladeSensor20Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 34 } bladeSensor21Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 35 } bladeSensor22Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 36 } bladeSensor23Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 37 } bladeSensor24Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 38 } bladeSensor25Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 39 } bladeSensor26Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 40 } bladeSensor27Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 41 } bladeSensor28Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 42 } bladeSensor29Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 43 } bladeSensor30Volt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltagesEntry 44 } bladeVoltageThresholdsTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeVoltageThresholdsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade VoltageThresholds information." ::= { bladeMonitors 6 } bladeVoltageThresholdsEntry OBJECT-TYPE SYNTAX BladeVoltageThresholdsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade voltage thresholds table entry" INDEX { voltageThresholdIndex } ::= { bladeVoltageThresholdsTable 1 } BladeVoltageThresholdsEntry ::= SEQUENCE { voltageThresholdIndex INTEGER, voltageThresholdBladeId INTEGER, voltageThresholdBladeExists INTEGER, voltageThresholdBladePowerState INTEGER, voltageThresholdBladeName OCTET STRING, bladePlus5VoltHighWarning OCTET STRING, bladePlus5VoltLowWarning OCTET STRING, bladePlus3pt3VoltHighWarning OCTET STRING, bladePlus3pt3VoltLowWarning OCTET STRING, bladePlus12VoltHighWarning OCTET STRING, bladePlus12VoltLowWarning OCTET STRING, bladePlus2pt5VoltHighWarning OCTET STRING, bladePlus2pt5VoltLowWarning OCTET STRING, bladePlus1pt5VoltHighWarning OCTET STRING, bladePlus1pt5VoltLowWarning OCTET STRING, bladePlus1pt25VoltHighWarning OCTET STRING, bladePlus1pt25VoltLowWarning OCTET STRING, bladeVoltThresholdSensorCapability INTEGER, bladeSensor1VoltHighWarning OCTET STRING, bladeSensor1VoltLowWarning OCTET STRING, bladeSensor2VoltHighWarning OCTET STRING, bladeSensor2VoltLowWarning OCTET STRING, bladeSensor3VoltHighWarning OCTET STRING, bladeSensor3VoltLowWarning OCTET STRING, bladeSensor4VoltHighWarning OCTET STRING, bladeSensor4VoltLowWarning OCTET STRING, bladeSensor5VoltHighWarning OCTET STRING, bladeSensor5VoltLowWarning OCTET STRING, bladeSensor6VoltHighWarning OCTET STRING, bladeSensor6VoltLowWarning OCTET STRING, bladeSensor7VoltHighWarning OCTET STRING, bladeSensor7VoltLowWarning OCTET STRING, bladeSensor8VoltHighWarning OCTET STRING, bladeSensor8VoltLowWarning OCTET STRING, bladeSensor9VoltHighWarning OCTET STRING, bladeSensor9VoltLowWarning OCTET STRING, bladeSensor10VoltHighWarning OCTET STRING, bladeSensor10VoltLowWarning OCTET STRING, bladeSensor11VoltHighWarning OCTET STRING, bladeSensor11VoltLowWarning OCTET STRING, bladeSensor12VoltHighWarning OCTET STRING, bladeSensor12VoltLowWarning OCTET STRING, bladeSensor13VoltHighWarning OCTET STRING, bladeSensor13VoltLowWarning OCTET STRING, bladeSensor14VoltHighWarning OCTET STRING, bladeSensor14VoltLowWarning OCTET STRING, bladeSensor15VoltHighWarning OCTET STRING, bladeSensor15VoltLowWarning OCTET STRING, bladeSensor16VoltHighWarning OCTET STRING, bladeSensor16VoltLowWarning OCTET STRING, bladeSensor17VoltHighWarning OCTET STRING, bladeSensor17VoltLowWarning OCTET STRING, bladeSensor18VoltHighWarning OCTET STRING, bladeSensor18VoltLowWarning OCTET STRING, bladeSensor19VoltHighWarning OCTET STRING, bladeSensor19VoltLowWarning OCTET STRING, bladeSensor20VoltHighWarning OCTET STRING, bladeSensor20VoltLowWarning OCTET STRING, bladeSensor21VoltHighWarning OCTET STRING, bladeSensor21VoltLowWarning OCTET STRING, bladeSensor22VoltHighWarning OCTET STRING, bladeSensor22VoltLowWarning OCTET STRING, bladeSensor23VoltHighWarning OCTET STRING, bladeSensor23VoltLowWarning OCTET STRING, bladeSensor24VoltHighWarning OCTET STRING, bladeSensor24VoltLowWarning OCTET STRING, bladeSensor25VoltHighWarning OCTET STRING, bladeSensor25VoltLowWarning OCTET STRING, bladeSensor26VoltHighWarning OCTET STRING, bladeSensor26VoltLowWarning OCTET STRING, bladeSensor27VoltHighWarning OCTET STRING, bladeSensor27VoltLowWarning OCTET STRING, bladeSensor28VoltHighWarning OCTET STRING, bladeSensor28VoltLowWarning OCTET STRING, bladeSensor29VoltHighWarning OCTET STRING, bladeSensor29VoltLowWarning OCTET STRING, bladeSensor30VoltHighWarning OCTET STRING, bladeSensor30VoltLowWarning OCTET STRING } voltageThresholdIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade voltage thresholds table index." ::= { bladeVoltageThresholdsEntry 1 } voltageThresholdBladeId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { bladeVoltageThresholdsEntry 2 } voltageThresholdBladeExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the server blade specified exists or not." ::= { bladeVoltageThresholdsEntry 3 } voltageThresholdBladePowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), standby(3), hibernate(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the power state of the blade specified." ::= { bladeVoltageThresholdsEntry 4 } voltageThresholdBladeName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The name of the blade as a null terminated string." ::= { bladeVoltageThresholdsEntry 5 } bladePlus5VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 6 } bladePlus5VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 7 } bladePlus3pt3VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 8 } bladePlus3pt3VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 9 } bladePlus12VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 10 } bladePlus12VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 11 } bladePlus2pt5VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 14 } bladePlus2pt5VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 15 } bladePlus1pt5VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 16 } bladePlus1pt5VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 17 } bladePlus1pt25VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 18 } bladePlus1pt25VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 19 } bladeVoltThresholdSensorCapability OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the server blade is IPMI capable or not." ::= { bladeVoltageThresholdsEntry 22 } bladeSensor1VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 23 } bladeSensor1VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 24 } bladeSensor2VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 25 } bladeSensor2VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 26 } bladeSensor3VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 27 } bladeSensor3VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 28 } bladeSensor4VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 29 } bladeSensor4VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 30 } bladeSensor5VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 31 } bladeSensor5VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 32 } bladeSensor6VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 33 } bladeSensor6VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 34 } bladeSensor7VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 35 } bladeSensor7VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 36 } bladeSensor8VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 37 } bladeSensor8VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 38 } bladeSensor9VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 39 } bladeSensor9VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 40 } bladeSensor10VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 41 } bladeSensor10VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 42 } bladeSensor11VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 43 } bladeSensor11VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 44 } bladeSensor12VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 45 } bladeSensor12VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 46 } bladeSensor13VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 47 } bladeSensor13VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 48 } bladeSensor14VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 49 } bladeSensor14VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 50 } bladeSensor15VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 51 } bladeSensor15VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 52 } bladeSensor16VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 53 } bladeSensor16VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 54 } bladeSensor17VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 55 } bladeSensor17VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 56 } bladeSensor18VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 57 } bladeSensor18VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 58 } bladeSensor19VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 59 } bladeSensor19VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 60 } bladeSensor20VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 61 } bladeSensor20VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 62 } bladeSensor21VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 63 } bladeSensor21VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 64 } bladeSensor22VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 65 } bladeSensor22VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 66 } bladeSensor23VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 67 } bladeSensor23VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 68 } bladeSensor24VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 69 } bladeSensor24VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 70 } bladeSensor25VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 71 } bladeSensor25VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 72 } bladeSensor26VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 73 } bladeSensor26VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 74 } bladeSensor27VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 75 } bladeSensor27VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 76 } bladeSensor28VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 77 } bladeSensor28VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 78 } bladeSensor29VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 79 } bladeSensor29VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 80 } bladeSensor30VoltHighWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 81 } bladeSensor30VoltLowWarning OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Voltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be generated. An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal digit or blank space for a leading zero. The string 'Not Readable!' indicates that the given monitor is not supported on this system. The string 'No Voltage' indicates that the given monitor does not exist on this system or is powered off." ::= { bladeVoltageThresholdsEntry 82 } bladeIOCompatibilityTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeIOCompatibilityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of IO Compatibility status for the blade." ::= { bladeMonitors 7 } bladeIOCompatibilityEntry OBJECT-TYPE SYNTAX BladeIOCompatibilityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade IO Compatibility Status entry" INDEX { bladeIOCompatibilityIndex } ::= { bladeIOCompatibilityTable 1 } BladeIOCompatibilityEntry ::= SEQUENCE { bladeIOCompatibilityIndex INTEGER, bladeIOCompatibilityBladeId INTEGER, bladeIOCompatibilityBayNumber INTEGER, bladeIOCompatibilityModuleBay OCTET STRING, bladeIOCompatibilityModulePower OCTET STRING, bladeIOCompatibilityModuleFabricType OCTET STRING, bladeIOCompatibilityFabricOnBlade OCTET STRING, bladeIOCompatibilityStatus OCTET STRING } bladeIOCompatibilityIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The blade I/O compatibility table index." ::= { bladeIOCompatibilityEntry 1 } bladeIOCompatibilityBladeId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The blade numeric identifier." ::= { bladeIOCompatibilityEntry 2 } bladeIOCompatibilityBayNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Bay number of the blade or expension card." ::= { bladeIOCompatibilityEntry 3 } bladeIOCompatibilityModuleBay OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The modules (each one specified by module type and bay number) that the blade can communicate with over the midplane networking fabric (i.e. a physical path exists between the blade and this module, and hardware exists on the blade to communicate with this module). " ::= { bladeIOCompatibilityEntry 4 } bladeIOCompatibilityModulePower OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The power state of the module specified in bladeIOCompatibilityModuleBay. n/a if module not installed." ::= { bladeIOCompatibilityEntry 5 } bladeIOCompatibilityModuleFabricType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The fabric type of the module specified in bladeIOCompatibilityModuleBay." ::= { bladeIOCompatibilityEntry 6 } bladeIOCompatibilityFabricOnBlade OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The fabric type for this channel on the blade (may be onboard fabric or an expansion card)." ::= { bladeIOCompatibilityEntry 7 } bladeIOCompatibilityStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The compatibility status between the blade and the module specified in bladeIOCompatibilityModuleBay. The possible values are: OK: No compatibility issues No IOM: There is no module on the other side of the wire for this channel on the blade. n/a: (Not applicable) The module specified in bladeIOCompatibilityModuleBay is a bridge, so the blade port cannot connect to it. Attention: The module specified in bladeIOCompatibilityModuleBay has a communication error. Mismatch: Indicates one of the following cases: Fabric types are incompatible Module specified in bladeIOCompatibilityModuleBay is of unknown type Unknown fabric type on the blade" ::= { bladeIOCompatibilityEntry 8 } bladePowerRestart OBJECT IDENTIFIER ::= { processorBlade 6 } -- blade power/restart control bladePowerRestartTable OBJECT-TYPE SYNTAX SEQUENCE OF BladePowerRestartEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade remote power control information. Contains power on/off enablement status for each blade." ::= { bladePowerRestart 1 } bladePowerRestartEntry OBJECT-TYPE SYNTAX BladePowerRestartEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade power restart table entry" INDEX { powerRestartIndex } ::= { bladePowerRestartTable 1 } BladePowerRestartEntry ::= SEQUENCE { powerRestartIndex INTEGER, powerRestartBladeId INTEGER, powerRestartBladeExists INTEGER, powerRestartBladePowerState INTEGER, powerRestartBladeHealthState INTEGER, powerRestartBladeName OCTET STRING, powerOnOffBlade INTEGER, restartBlade INTEGER, restartBladeSMP INTEGER, restartBladeNMI INTEGER, restartBladeClearNVRAM INTEGER, restartBladeInvokeDiags INTEGER, restartBladeInvokeDiagsFromDefaultBootList INTEGER, restartBladeToSMSBootMenu INTEGER, restartBladeToUEFIMenu INTEGER } powerRestartIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade power restart table index." ::= { bladePowerRestartEntry 1 } powerRestartBladeId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { bladePowerRestartEntry 2 } powerRestartBladeExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the server blade specified exists or not." ::= { bladePowerRestartEntry 3 } powerRestartBladePowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), standby(3), hibernate(4), unknown(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the power state of the blade specified. If the state cannot be determined, the unknown(255) value is returned." ::= { bladePowerRestartEntry 4 } powerRestartBladeHealthState OBJECT-TYPE SYNTAX INTEGER { unknown(0), good(1), warning(2), critical(3), kernelMode(4), discovering(5), commError(6), noPower(7), flashing(8), initFailure(9), insufficientPower(10), powerDenied(11) } ACCESS read-only STATUS mandatory DESCRIPTION "The system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings exist for this blade. Critical: One or more outstanding critical events for this blade. Kernel Mode: Blade is in kernel mode. Discovering: The AMM is currently in the process of discovering this blade. Communications Error: The AMM failed to communicate with this blade. No Power: No power to the blade's domain. Flashing: Flashing in progress. Initialization Failure: Blade failed to initialized. Insufficient Power: Not enough power is left in the blade's domain to power the blade. Power Denied: Power was denied to the blade." ::= { bladePowerRestartEntry 5 } powerRestartBladeName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the blade as a null terminated string." ::= { bladePowerRestartEntry 6 } powerOnOffBlade OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), softoff(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the power state of a specific blade. Off: Power Off Blade. On: Power On Blade. Softoff: Shut Down OS and Power Off Blade. This operation is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object. The powerRestartBladePowerState MIB object should be used to check the power state of the blade(s)" ::= { bladePowerRestartEntry 7 } restartBlade OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Restart a blade. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { bladePowerRestartEntry 8 } restartBladeSMP OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Restart a blade's system management processor. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { bladePowerRestartEntry 9 } restartBladeNMI OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Issue an NMI to the blade. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { bladePowerRestartEntry 10 } restartBladeClearNVRAM OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Restart a blade and set NVRAM to default values. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { bladePowerRestartEntry 11 } restartBladeInvokeDiags OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Restart a blade and boot into diagnostic mode. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { bladePowerRestartEntry 12 } restartBladeInvokeDiagsFromDefaultBootList OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Restart a blade and boot into diagnostic mode from Default Boot List as defined on the blade. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { bladePowerRestartEntry 13 } restartBladeToSMSBootMenu OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Restart a blade to SMS boot menu. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { bladePowerRestartEntry 14 } restartBladeToUEFIMenu OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Restart a blade to UEFI setup menu. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { bladePowerRestartEntry 15 } bladeConfiguration OBJECT IDENTIFIER ::= { processorBlade 7 } -- blade power/restart control bladeConfigurationTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeConfigurationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade remote power control information. Contains power on/off enablement status for each blade." ::= { bladeConfiguration 1 } bladeConfigurationEntry OBJECT-TYPE SYNTAX BladeConfigurationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade configuration table entry" INDEX { configurationIndex } ::= { bladeConfigurationTable 1 } BladeConfigurationEntry ::= SEQUENCE { configurationIndex INTEGER, configurationBladeId INTEGER, configurationBladeExists INTEGER, configurationBladePowerState INTEGER, configurationBladeName OCTET STRING, configurationBladecKVM INTEGER, configurationBladeActiveBootMode INTEGER, configurationBladePendingBootMode INTEGER } configurationIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade configuration table index." ::= { bladeConfigurationEntry 1 } configurationBladeId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { bladeConfigurationEntry 2 } configurationBladeExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the server blade specified exists or not." ::= { bladeConfigurationEntry 3 } configurationBladePowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), standby(3), hibernate(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the power state of the blade specified." ::= { bladeConfigurationEntry 4 } configurationBladeName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The name of the blade as a null terminated string." ::= { bladeConfigurationEntry 5 } configurationBladecKVM OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1), notPresent(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the concurrent KVM function on specified blade. If concurrent KVM is not supported by the blade, it displays 'notPresent' and the concurrent KVM functionality can not be enabled or disabled." ::= { bladeConfigurationEntry 6 } configurationBladeActiveBootMode OBJECT-TYPE SYNTAX INTEGER { temporary(1), permanent(2), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the active copy of the firmware from which the blade is booting. NOTE: Some blades do not support the automatic boot recovery. It displays 'notApplicable' for such blades. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible." ::= { bladeConfigurationEntry 7 } configurationBladePendingBootMode OBJECT-TYPE SYNTAX INTEGER { temporary(1), permanent(2), notApplicable(255) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the copy of the firmware from which the blade will boot after the next reboot. NOTE: Some blades do not support the automatic boot recovery. It displays 'notApplicable' for such blades and the value can not be set. Booting from the temporary copy is recommended since it typically contains the latest enhancements and fixes. Switching to the permanent copy should be reserved for when booting from the temporary copy is no longer possible." ::= { bladeConfigurationEntry 8 } -- Power Management Policy Settings bladePowerManagementPolicy OBJECT IDENTIFIER ::= { bladeConfiguration 2 } powerdomain1Oversubscription OBJECT-TYPE SYNTAX INTEGER { not-allowed(0), recoverable(1), non-recoverable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Power Management Policy settings for power domain 1." ::= { bladePowerManagementPolicy 1 } powerdomain2Oversubscription OBJECT-TYPE SYNTAX INTEGER { not-allowed(0), recoverable(1), non-recoverable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Power Management Policy settings for power domain 2." ::= { bladePowerManagementPolicy 2 } acousticMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Acoustic mode setting for thermal conditions" ::= { bladePowerManagementPolicy 3 } nebsMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "NEBS (Network Equipment-Building System) mode setting for thermal conditions. NOTE: This MIB object is for BladeCenter T, HT and TR only." ::= { bladePowerManagementPolicy 4 } bladecKVMEnableDisable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable cKVM function on all server blades." ::= { bladeConfiguration 3 } bladeIPAddrRangeStart OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS deprecated DESCRIPTION "This field is used to configure the start of the IP address range for the blade system management processors on the blades. These addresses are used on the internal management network between the MM and the blade BSMPs. For example the value of 10.10.10.1 means the BSMP on the blade in bay 1 will have IP address 10.10.10.1, the BSMP on the blade in bay 2 will have IP address 10.10.10.2 and so on. This field is deprecated and no longer supported. An attempt to SET this object will be rejected, and any query will always return 0.0.0.0. Refer to the bladeManagementNetworkInfoTable for the new objects providing this information." ::= { processorBlade 8 } bladeCapacityOnDemand OBJECT IDENTIFIER ::= { processorBlade 9 } bladeCapacityOnDemandTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeCapacityOnDemandEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Table of COD blade. NOTE: This table is deprecated and no longer supported." ::= { bladeCapacityOnDemand 1 } bladeCapacityOnDemandEntry OBJECT-TYPE SYNTAX BladeCapacityOnDemandEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Blade COD table entry NOTE: This table is deprecated and no longer supported." INDEX { bladeCapacityOnDemandIndex } ::= { bladeCapacityOnDemandTable 1 } BladeCapacityOnDemandEntry ::= SEQUENCE { bladeCapacityOnDemandIndex INTEGER, -- deprecated bladeCapacityOnDemandBladeName OCTET STRING, -- deprecated bladeCapacityOnDemandState INTEGER -- deprecated } bladeCapacityOnDemandIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Blade configuration table index. NOTE: This Mib object is deprecated and no longer supported." ::= { bladeCapacityOnDemandEntry 1 } bladeCapacityOnDemandBladeName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "The name of the blade as a null terminated string. NOTE: This Mib object is deprecated and no longer supported." ::= { bladeCapacityOnDemandEntry 2 } bladeCapacityOnDemandState OBJECT-TYPE SYNTAX INTEGER { none(0), standby(1), active(2) } ACCESS read-write STATUS deprecated DESCRIPTION "The state of Capacity On Demand. NOTE: This Mib object is deprecated and no longer supported." ::= { bladeCapacityOnDemandEntry 3 } bladeBootCountPowerOnTime OBJECT IDENTIFIER ::= { processorBlade 10 } -- blade Count of number of boots for a blade and its Power On Time bladeBootCountPowerOnTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeBootCountPowerOnTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table per blade of the number of boots for the blade and the number of seconds the blade has been powered on." ::= { bladeBootCountPowerOnTime 1 } bladeBootCountPowerOnTimeEntry OBJECT-TYPE SYNTAX BladeBootCountPowerOnTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The number of boots for the blade and the number of seconds the blade has been powered on." INDEX { bootCountPowerOnTimeBladeIndex } ::= { bladeBootCountPowerOnTimeTable 1 } BladeBootCountPowerOnTimeEntry ::= SEQUENCE { bootCountPowerOnTimeBladeIndex INTEGER, bootCountPowerOnTimeBladeId INTEGER, bootCountPowerOnTimeBoots INTEGER, bootCountPowerOnTimeSecs INTEGER } bootCountPowerOnTimeBladeIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade boot count/Power On Time table index." ::= { bladeBootCountPowerOnTimeEntry 1 } bootCountPowerOnTimeBladeId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { bladeBootCountPowerOnTimeEntry 2 } bootCountPowerOnTimeBoots OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Blade Boot Count. If there is no blade in the given slot then this value is undefined. Writing this value resets the Boot Count to zero." ::= { bladeBootCountPowerOnTimeEntry 3 } bootCountPowerOnTimeSecs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Blade Power On Time in seconds. If there is no blade in the given slot then this value is undefined. Writing this value resets the Power On Time to zero." ::= { bladeBootCountPowerOnTimeEntry 4 } bladeVlanId OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This is the virtual LAN ID for the internal management network between the MM and the blade system management processors (BSMPs). The range of valid VLAN ID's is 3 to 4095." ::= { processorBlade 11 } --- --- Blade Bay Data Table MIB objects --- bladeBayDataTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeBayDataEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade bay data (BBD) information." ::= { processorBlade 13 } bladeBayDataEntry OBJECT-TYPE SYNTAX BladeBayDataEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade bay data (BBD) table entry." INDEX { bayDataIndex } ::= { bladeBayDataTable 1 } BladeBayDataEntry ::= SEQUENCE { bayDataIndex INTEGER, bayDataBladeId INTEGER, bayDataBladeExists INTEGER, bayDataBladePowerState INTEGER, bayDataBladeName OCTET STRING, bayData OCTET STRING, bayDataBladeStatus INTEGER } bayDataIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade bay data (BBD) table index." ::= { bladeBayDataEntry 1 } bayDataBladeId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { bladeBayDataEntry 2 } bayDataBladeExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the server blade specified exists or not." ::= { bladeBayDataEntry 3 } bayDataBladePowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), standby(3), hibernate(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the power state of the blade specified." ::= { bladeBayDataEntry 4 } bayDataBladeName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the blade as a null terminated string." ::= { bladeBayDataEntry 5 } bayData OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A null terminated string that defines the Blade Bay Data (BBD). This data is pushed to the blade's BSMP and SMBIOS structures, where it can used by the blade's OS. Up to 60 characters can be defined plus a Null terminator." ::= { bladeBayDataEntry 6 } bayDataBladeStatus OBJECT-TYPE SYNTAX INTEGER { supported(0), bsmp(1), notPresent(2), discovering(3), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "This shows Blade Bay Data (BBD) status. 0 means the blade fully supports BBD; 1 means that the blade's BIOS does not support BBD; 2 means that there is no blade in the bay; 3 means that the blade is being discovered. 255 means that the blade does not support BBD." ::= { bladeBayDataEntry 7 } bladeNetworkConfiguration OBJECT IDENTIFIER ::= { processorBlade 12 } -- blade network configuration for all blades bladeNetworkInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeNetworkInterfaceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all blades' network interfaces." ::= { bladeNetworkConfiguration 2 } bladeNetworkInterfaceEntry OBJECT-TYPE SYNTAX BladeNetworkInterfaceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade configuration table entry" INDEX { bladeNetworkInterfaceIndex } ::= { bladeNetworkInterfaceTable 1 } BladeNetworkInterfaceEntry ::= SEQUENCE { bladeNetworkInterfaceIndex INTEGER, bladeNetworkInterfaceBayNumber OCTET STRING, bladeNetworkInterfaceNumber INTEGER, bladeNetworkInterfaceType INTEGER, bladeNetworkInterfaceLabel OCTET STRING, bladeNetworkInterfaceIPAddr IpAddress, bladeNetworkInterfaceSubnetMask IpAddress, bladeNetworkInterfaceGatewayAddr IpAddress, bladeNetworkInterfaceVlanId INTEGER, bladeNetworkInterfaceVlanEnable INTEGER, bladeNetworkInterfaceEnable INTEGER, bladeNetworkInterfaceDHCPEnable INTEGER, bladeNetworkInterfaceMACAddr OCTET STRING, bladeNetworkInterfaceAssignedSwitch INTEGER } bladeNetworkInterfaceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade Network Interface Table index." ::= { bladeNetworkInterfaceEntry 1 } bladeNetworkInterfaceBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The bay number of the main server blade that supports network interface management" ::= { bladeNetworkInterfaceEntry 2 } bladeNetworkInterfaceNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates which network interface on the blade System Management Processor is be read or writen" ::= { bladeNetworkInterfaceEntry 3 } bladeNetworkInterfaceType OBJECT-TYPE SYNTAX INTEGER { private(1), public(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates blade network interface type." ::= { bladeNetworkInterfaceEntry 4 } bladeNetworkInterfaceLabel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Show string label that identifies the interface." ::= { bladeNetworkInterfaceEntry 5 } bladeNetworkInterfaceIPAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Show/modify current IP address of the blade network interface. Note that only if the bladeNetworkInterfaceEnable is 'enabled(1)' and the bladeNetworkInterfaceDHCPEnable is not 'dhcpEnabled(1)', should the IP address be pushed down to blade System Management Processor" ::= { bladeNetworkInterfaceEntry 6 } bladeNetworkInterfaceSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Show or modifie current subnet mask of the blade network interface. Note that only if the bladeNetworkInterfaceEnable is 'enabled(1)' and the bladeNetworkInterfaceDHCPEnable is not 'dhcpEnabled(1)', should the SunnetMask be pushed down to blade System Management Processor" ::= { bladeNetworkInterfaceEntry 7 } bladeNetworkInterfaceGatewayAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Show or modify current IP gateway of the blade network interface. Note that only if the bladeNetworkInterfaceEnable is 'enabled(1)' and the bladeNetworkInterfaceDHCPEnable is not 'dhcpEnabled(1)', should the Gateway address be pushed down to blade System Management Processor" ::= { bladeNetworkInterfaceEntry 8 } bladeNetworkInterfaceVlanId OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This is the Virtual LAN ID for supported network interface cards (NICs). The range of valid VLAN ID's is 0 to 4095." ::= { bladeNetworkInterfaceEntry 9 } bladeNetworkInterfaceVlanEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1), notApplicable(255) } ACCESS read-only STATUS deprecated DESCRIPTION "This object is no longer supported and will always be 0" ::= { bladeNetworkInterfaceEntry 10 } bladeNetworkInterfaceEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1), notApplicable(255) } ACCESS read-write STATUS mandatory DESCRIPTION "Disabled or enabled the blade network interface. If the network interface is disabled, then ignore other configurations. If this network interface doesn't support enabled/disabled, show 'notApplicable(255)'" ::= { bladeNetworkInterfaceEntry 11 } bladeNetworkInterfaceDHCPEnable OBJECT-TYPE SYNTAX INTEGER { dhcpDisabled(0), dhcpEnabled(1), tryDhcpThenTryStatic(2), notApplicable(255) } ACCESS read-write STATUS mandatory DESCRIPTION "IP config method on the blade network interface to modify mode to static IP, dhcp and dhcpthenstatic. If this network interface doesn't support DHCP, show 'notApplicable(255)'" ::= { bladeNetworkInterfaceEntry 12 } bladeNetworkInterfaceMACAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Show the blade network interface MAC address. If this network interface doesn't support MAC, show 'notApplicable'" ::= { bladeNetworkInterfaceEntry 13 } bladeNetworkInterfaceAssignedSwitch OBJECT-TYPE SYNTAX INTEGER { notAssigned(0), module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10), notApplicable(255)} ACCESS read-write STATUS mandatory DESCRIPTION "This field allows you to select an I/O Module to use for management traffic to the blade. NOTE: This field is only supported for eth1 of blade. NOTE: You may only specify ethernet switches to this field." ::= { bladeNetworkInterfaceEntry 14 } bladeIPv6Config OBJECT IDENTIFIER ::= { bladeNetworkConfiguration 10 } bladeIPv6ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeIPv6ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of IPv6 configuration options for blades. NOTE: This MIB object is not applicable to blades that do not support IPv6." ::= { bladeIPv6Config 1 } bladeIPv6ConfigEntry OBJECT-TYPE SYNTAX BladeIPv6ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "IPv6 configuration options for a blade. NOTE: This MIB object is not applicable to blades that do not support IPv6." INDEX { bladeIPv6ConfigIndex, bladeIPv6ConfigPortIndex } ::= { bladeIPv6ConfigTable 1 } BladeIPv6ConfigEntry ::= SEQUENCE { bladeIPv6ConfigIndex INTEGER, bladeIPv6ConfigPortIndex INTEGER, bladeIPv6ConfigEnabled INTEGER, bladeIPv6ConfigStatic INTEGER, bladeDHCPv6ConfigEnabled INTEGER, bladeIPv6ConfigStatelessEnabled INTEGER } bladeIPv6ConfigIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The blade's slot number" ::= { bladeIPv6ConfigEntry 1 } bladeIPv6ConfigPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The physical port number of the given entry" ::= { bladeIPv6ConfigEntry 2 } bladeIPv6ConfigEnabled OBJECT-TYPE SYNTAX INTEGER { disable(0),enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables/Disables IPv6 support on the blade." ::= { bladeIPv6ConfigEntry 3 } bladeIPv6ConfigStatic OBJECT-TYPE SYNTAX INTEGER { disable(0),enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables/Disables IPv6 static configuration support on the blade." ::= { bladeIPv6ConfigEntry 4 } bladeDHCPv6ConfigEnabled OBJECT-TYPE SYNTAX INTEGER { disable(0),enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables/Disables DHCPv6 address configuration support on the blade." ::= { bladeIPv6ConfigEntry 5 } bladeIPv6ConfigStatelessEnabled OBJECT-TYPE SYNTAX INTEGER { disable(0),enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables/Disables IPv6 stateless auto-configuration support on the blade." ::= { bladeIPv6ConfigEntry 6 } bladeIPv6AddressTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeIPv6AddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of assigned IPv6 addresses for blades. NOTE: This MIB object is not applicable to blades that do not support IPv6." ::= { bladeIPv6Config 2 } bladeIPv6AddressEntry OBJECT-TYPE SYNTAX BladeIPv6AddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The assigned IPv6 address for a given blade. NOTE: This MIB object is not applicable to blades that do not support IPv6." INDEX { bladeIPv6AddressIndex, bladeIPv6AddressPortIndex, bladeIPv6AddressEntryIndex} ::= { bladeIPv6AddressTable 1 } BladeIPv6AddressEntry ::= SEQUENCE { bladeIPv6AddressIndex INTEGER, bladeIPv6AddressPortIndex INTEGER, bladeIPv6AddressEntryIndex INTEGER, bladeIPv6AddressType INTEGER, bladeIPv6Address InetAddressIPv6, bladeIPv6AddressPrefixLen INTEGER, bladeIPv6AddressDefaultRoute InetAddressIPv6 } bladeIPv6AddressIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The blade's slot number." ::= { bladeIPv6AddressEntry 1 } bladeIPv6AddressPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The blade's physical port number for the given entry." ::= { bladeIPv6AddressEntry 2 } bladeIPv6AddressEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The blade's address entry index." ::= { bladeIPv6AddressEntry 3 } bladeIPv6AddressType OBJECT-TYPE SYNTAX INTEGER { active-static(1), dhcp6(2), link-local(3), autconfig(4), current(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The address type." ::= { bladeIPv6AddressEntry 4 } bladeIPv6Address OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-write STATUS mandatory DESCRIPTION "The assigned IPv6 address. Note: 'write' is for static ipv6 only." ::= { bladeIPv6AddressEntry 5 } bladeIPv6AddressPrefixLen OBJECT-TYPE SYNTAX INTEGER (1..128) ACCESS read-write STATUS mandatory DESCRIPTION "The prefix length for the given address. Note: 'write' is for static ipv6 only." ::= { bladeIPv6AddressEntry 6 } bladeIPv6AddressDefaultRoute OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-write STATUS mandatory DESCRIPTION "The default route used for the given address. Note: 'write' is for static ipv6 only." ::= { bladeIPv6AddressEntry 7 } bladeSPEthOverUSBInterface OBJECT IDENTIFIER ::= { processorBlade 14 } spEthOverUSBInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF SPEthOverUSBInterfaceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade Service Processor's Ethernet over USB interface." ::= { bladeSPEthOverUSBInterface 1 } spEthOverUSBInterfaceEntry OBJECT-TYPE SYNTAX SPEthOverUSBInterfaceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade Service Processor's Ethernet over USB interface entry." INDEX { spEthOverUSBInterfaceIndex } ::= { spEthOverUSBInterfaceTable 1 } SPEthOverUSBInterfaceEntry ::= SEQUENCE { spEthOverUSBInterfaceIndex INTEGER, spEthOverUSBInterfaceBladeId OCTET STRING, spEthOverUSBInterfaceBladeExists INTEGER, spEthOverUSBInterfaceBladeName OCTET STRING, spEthOverUSBInterfaceEnable INTEGER } spEthOverUSBInterfaceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Service Processor's Ethernet over USB interface table index." ::= { spEthOverUSBInterfaceEntry 1 } spEthOverUSBInterfaceBladeId OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { spEthOverUSBInterfaceEntry 2 } spEthOverUSBInterfaceBladeExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the blade specified exists or not." ::= { spEthOverUSBInterfaceEntry 3 } spEthOverUSBInterfaceBladeName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the blade as a null terminated string." ::= { spEthOverUSBInterfaceEntry 6 } spEthOverUSBInterfaceEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1), notApplicable(255) } ACCESS read-write STATUS mandatory DESCRIPTION "This object allows the user to view the status of, and enable or disable, a blade Service Processor's command interface on Ethernet-over-USB. NOTE: If the blade either does not exist or does not support Ethernet-over-USB command interface. It displays 'notApplicable'. NOTE: It will take about 10 or more seconds for the disable/enable setting to take effect." ::= { spEthOverUSBInterfaceEntry 9 } -- Blade management network auto discovery bladeManagementNetwork OBJECT IDENTIFIER ::= { processorBlade 15 } bladeManagementNetworkControlEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Globally disable/enable blade management network auto discovery support." ::= { bladeManagementNetwork 1 } --Blade Management Network Info Table bladeManagementNetworkInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeManagementNetworkInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade management network information." ::= { bladeManagementNetwork 2 } bladeManagementNetworkInfoEntry OBJECT-TYPE SYNTAX BladeManagementNetworkInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade management network information entry." INDEX { bladeManagementNetworkInfoIndex } ::= { bladeManagementNetworkInfoTable 1 } BladeManagementNetworkInfoEntry ::= SEQUENCE { bladeManagementNetworkInfoIndex INTEGER, bladeManagementNetworkInfoBladeId INTEGER, bladeManagementNetworkInfoBladeExist INTEGER, bladeManagementNetworkInfoBladeSupport INTEGER, bladeManagementNetworkInfoPathStatus INTEGER, bladeManagementNetworkInfoBladeIPAddr IpAddress, bladeManagementNetworkInfoBladeMACAddr OCTET STRING, bladeManagementNetworkInfoSwitchId INTEGER } bladeManagementNetworkInfoIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade management network information table index" ::= { bladeManagementNetworkInfoEntry 1 } bladeManagementNetworkInfoBladeId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The Blade ID." ::= { bladeManagementNetworkInfoEntry 2 } bladeManagementNetworkInfoBladeExist OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the blade specified exists or not in the chassis." ::= { bladeManagementNetworkInfoEntry 3 } bladeManagementNetworkInfoBladeSupport OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the blade supports the management network auto discovery capability or not." ::= { bladeManagementNetworkInfoEntry 4 } bladeManagementNetworkInfoPathStatus OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the status of the management network for this blade." ::= { bladeManagementNetworkInfoEntry 5 } bladeManagementNetworkInfoBladeIPAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the blade system management processor IPv4 address." ::= { bladeManagementNetworkInfoEntry 6 } bladeManagementNetworkInfoBladeMACAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the blade system management processor MAC address." ::= { bladeManagementNetworkInfoEntry 7 } bladeManagementNetworkInfoSwitchId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates which switch is selected for the blade management network." ::= { bladeManagementNetworkInfoEntry 8 } -- ******************************************************************************** -- Switch module control and config -- ******************************************************************************** switchModule OBJECT IDENTIFIER ::= { blades 3 } -- Server blade switch module control and configuration -- ******************************************************************************** -- Switch module control -- ******************************************************************************** switchModuleControl OBJECT IDENTIFIER ::= { switchModule 1 } -- Server blade switch module control smControlTable OBJECT-TYPE SYNTAX SEQUENCE OF SmControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module control table." ::= { switchModuleControl 1 } smControlEntry OBJECT-TYPE SYNTAX SmControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module control table entry" INDEX { smControlIndex } ::= { smControlTable 1 } SmControlEntry ::= SEQUENCE { smControlIndex INTEGER, switchModuleControlId INTEGER, smPostResultsAvailable INTEGER, smPostResultsValue OCTET STRING, switchModuleMemDiagEnableDisable INTEGER, smCfgCtrlEnableDisable INTEGER, smExtEthPortsEnableDisable INTEGER, switchPingRequest INTEGER, smCfgCtrlOnResetEnableDisable INTEGER, smHealthState INTEGER, smPMState INTEGER, smPMCtrlEnableDisable INTEGER, smIOCompatibility OCTET STRING } smControlIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module control table index." ::= { smControlEntry 1 } switchModuleControlId OBJECT-TYPE SYNTAX INTEGER { module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The switch module numeric identifier." ::= { smControlEntry 2 } smPostResultsAvailable OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Describes whether the switch module POST diagnostic result value contained in the smPostResultsValue is valid." ::= { smControlEntry 3 } smPostResultsValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The range of values and meanings are as follows: 0x00 - 0x7F ( 0 - 127) Base internal functions 0x80 - 0x9F (128 - 159) Internal interface failures 0xA0 - 0xAF (160 - 175) External interface failures 0xB0 - 0xFE (176 - 254) Reserved 0xFF (255) Switch completed POST successfully" ::= { smControlEntry 4 } switchModuleMemDiagEnableDisable OBJECT-TYPE SYNTAX INTEGER { enabled(0), disabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Switch module memory diagnostics enabled or disabled. NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional (i.e. - 0 and 1 are swapped), however, they cannot be changed since this MIB is already published. " ::= { smControlEntry 5 } smCfgCtrlEnableDisable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Switch module configuration control. When set to enabled, only the MM can manage the module. This MIB object can not be set, if AMM grants switch module the Protected Mode permission. This MIB object can not be set, if the switch module is participating in the Stacking Mode and external management is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. A value of disabled(0) will be returned." ::= { smControlEntry 6 } smExtEthPortsEnableDisable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Switch module external ethernet ports enabled or disabled. This MIB object can not be set, if AMM grants switch module the Protected Mode permission. This MIB object can not be set, if the switch module is participating in the Stacking Mode and External Port Access is protected." ::= { smControlEntry 7 } switchPingRequest OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS deprecated DESCRIPTION "Sends a ping to a switch module's current IPv4 address. This MIB object can not be set, if AMM grants switch module the Protected Mode permission and switch module goes into Protected Mode. This MIB object can not be set, if the switch module is participating in the Stacking Mode and IP Configuration is protected. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This object has been deprecated in favor of the new table smPingTable which supports IPv6 and IPv4 addresses." ::= { smControlEntry 8 } smCfgCtrlOnResetEnableDisable OBJECT-TYPE SYNTAX INTEGER { enabled(0), disabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Switch module configuration control on resets (default and unsolicited). When set to enabled, the factory default IP configuration will become active when the I/O module is reset to factory defaults by either the management module or the I/O module. If an I/O module reset is initiated by a source other than the management module then the previous IP configuration will be in affect. In both these cases the MM will lose IP communications with the IOM. This MIB object can not be set, if AMM grants switch module the Protected Mode permission and switch module goes into Protected Mode. NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional (i.e. - 0 and 1 are swapped), however, they cannot be changed since this MIB is already published. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. A value of disabled(1) will be returned." ::= { smControlEntry 9 } smHealthState OBJECT-TYPE SYNTAX INTEGER { unknown(0), good(1), warning(2), bad(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The health state for the switch module. 0 = unknown, 1 = good, 2 = warning, 3 = bad." ::= { smControlEntry 15} smPMState OBJECT-TYPE SYNTAX INTEGER { disabled(0), pending(1), attention(2), active(3), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "The Protected Mode Status for the switch module. standby- Protected Mode capability exists on the IOM but has not been activated on the switch module or the AMM. pending - Protected Mode has been activated on the AMM but not yet on the switch module. active - Protected Mode is active on both the switch module and the AMM. attention - Protected Mode is enabled on the switch module but not on the AMM." ::= { smControlEntry 16} smPMCtrlEnableDisable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "AMM Protected Mode permission for the switch module. disabled - allow AMM to disable Protected Mode Permission for the switch module. enabled - allow AMM to grant Protected Mode Permission for the switch module." ::= { smControlEntry 17} smIOCompatibility OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The compatibility status for the I/O module. The possible values and their meanings are as follows: Unknown: This indicates a communication error for the I/O module. OK: This is the normal (good) case where there are no compatibility issues between the I/O module and the modules it is internally wired to. No Fabric: This means the other end is not populated on any of the modules this I/O module is internally wired to (e.g. this is an Infiniband switch but none of the blades it is internally wired to has an expansion card attached in the corresponding expansion slot). Attention: Indicates one of the following cases: One or more of the modules this I/O module is internally wired to is in communication error The I/O module is powered off and at least one module it is internally wired to is powered on Mismatch: Indicates one of the following cases: Fabric types are incompatible An unknown I/O module type An unknown fabric type on a module the I/O module is internally wired to." ::= { smControlEntry 18} smPingTable OBJECT-TYPE SYNTAX SEQUENCE OF SmPingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Allows pinging one of the active assigned addresses of an I/O module. NOTE: This table is not applicable to modules that are running in Stacking Mode and IP configuration is protected." ::= { switchModuleControl 2 } smPingEntry OBJECT-TYPE SYNTAX SmPingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Represents a single address that can be pinged" INDEX { smPingIndex, smPingAddressEntryIndex } ::= { smPingTable 1 } SmPingEntry ::= SEQUENCE { smPingIndex INTEGER, smPingAddressEntryIndex INTEGER, smPingAddress OCTET STRING, smPingAddressExecute INTEGER } smPingIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The switch module's slot number" ::= { smPingEntry 1 } smPingAddressEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The switch module's address entry index" ::= { smPingEntry 2 } smPingAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The switch module's IPv4 or IPv6 address" ::= { smPingEntry 3 } smPingAddressExecute OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Pings the given IP address. NOTE: The GET operation for this object is meaningless." ::= { smPingEntry 4 } smPowerRestartTable OBJECT-TYPE SYNTAX SEQUENCE OF SmPowerRestartEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module power restart table." ::= { switchModuleControl 7 } smPowerRestartEntry OBJECT-TYPE SYNTAX SmPowerRestartEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module power restart table entry" INDEX { smPowerRestartIndex } ::= { smPowerRestartTable 1 } SmPowerRestartEntry ::= SEQUENCE { smPowerRestartIndex INTEGER, smPowerRestartId INTEGER, smSwitchExists INTEGER, smSwitchType INTEGER, smMACAddress OCTET STRING, smIPAddress IpAddress, switchModulePowerOnOff INTEGER, smReset INTEGER, smResetToDefault INTEGER, smRestartAndRunStdDiag INTEGER, smRestartAndRunExtDiag INTEGER, smRestartAndRunFullDiag INTEGER, smSwitchSubType INTEGER, smSwitchWidth INTEGER, smManufacturingID OCTET STRING, smStackingModeState INTEGER, smStackingModeInfo OCTET STRING } smPowerRestartIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module power restart index." ::= { smPowerRestartEntry 1 } smPowerRestartId OBJECT-TYPE SYNTAX INTEGER { module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The switch module numeric identifier." ::= { smPowerRestartEntry 2 } smSwitchExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module specified exists or not." ::= { smPowerRestartEntry 3 } smSwitchType OBJECT-TYPE SYNTAX INTEGER { unknown(0), ethernet(1), fibre(2), opm(3), serialCM(4), copperPassThrough(5), infiniband(6), highSpeed(20), passThrough(30), sas(40) } ACCESS read-only STATUS mandatory DESCRIPTION "Switch module type." ::= { smPowerRestartEntry 4 } smMACAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module MAC address." ::= { smPowerRestartEntry 5 } smIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The switch module current IP address. If the switch module is participating in the Stacking Mode and IP Configuration is protected, then the stack management IP address is displayed. NOTE: IPv6 addresses for the switch can be view with the smIPv6AddressTable." ::= { smPowerRestartEntry 6 } switchModulePowerOnOff OBJECT-TYPE SYNTAX INTEGER { poweroff(0), poweron(1), shutdownInProgress(2) } ACCESS read-write STATUS mandatory DESCRIPTION "I/O Module power on or power off. If powering on a currently powered off I/O Module, then the I/O Module will execute a POST. The results of this POST will need to be retrieved using the 'Post Results' command. NOTE: When powering off a currently powered on I/O Module, a minimum of 1 second is needed to allow the module to power off before powering back on. The value 'shutdownInProgress' is for I/O Modules that may take some time to transition from 'poweron' to 'poweroff'. For example, SAS Controller Modules must flush pending I/O before powering off in order to maintain data integrity. The value'shutdownInProgress' can not be used to set. If both SAS Controller Module and SAS Connectivity Module are installed in slot 3 and 4 of BCS chassis, AMM must prevent one of them from powering on otherwise there would be conflict with the Storage Module access and possibly corruption of data. This MIB object can not be set, if AMM grants the I/O Module the Protected Mode permission and module goes into Protected Mode." ::= { smPowerRestartEntry 7 } smReset OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "For the case where the switch module is currently powered on, this command will effectively power off and then power on the switch module indicated and cause it to run its POST test. For the case where the switch module is currently powered off, the command will just power on the switch module. This MIB object can not be set, if AMM grants switch module the Protected Mode permission and switch module goes into Protected Mode. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { smPowerRestartEntry 8 } smResetToDefault OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "For the case where the switch module is currently powered on, this command will effectively power off and then power on the switch module indicated and cause it to run its POST test. For the case where the switch module is currently powered off, the command will just power on the switch module. In both cases, the switch module will reset the configuration to the default values. This MIB object can not be set, if AMM grants switch module the Protected Mode permission and switch module goes into Protected Mode. This MIB object can not be set, if the switch module is participating in the Stacking Mode and reset to default is protected. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { smPowerRestartEntry 9 } smRestartAndRunStdDiag OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To power cycle the selected module(s) and then run the standard diagnostic test package. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { smPowerRestartEntry 10 } smRestartAndRunExtDiag OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To power cycle the selected module(s) and then run the extended diagnostic test package. This option is not supported on all I/O modules. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { smPowerRestartEntry 11 } smRestartAndRunFullDiag OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To power cycle the selected module(s) and then run the full diagnostic test package. The full diagnostic test package may take over 5 minutes to run. This option is not supported on all I/O modules. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { smPowerRestartEntry 12 } smSwitchSubType OBJECT-TYPE SYNTAX INTEGER { unknown(0), ethernet(1), fibre(2), infiniband(6), sas(7), raidsas(8), icpm(9) } ACCESS read-only STATUS mandatory DESCRIPTION "Switch module subtype. NOTE: Some Legacy modules do not support a subtype and will be displayed as unknown." ::= { smPowerRestartEntry 20 } smSwitchWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module width." ::= { smPowerRestartEntry 21 } smManufacturingID OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch module hardware VPD manufacturing ID." ::= { smPowerRestartEntry 22 } smStackingModeState OBJECT-TYPE SYNTAX INTEGER { standby(0), member(1), master(2), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "The Stacking Mode Status for the switch module. standby - I/O module has stacking capability but is not part of a stack. member - I/O module has stacking capability and is part of a stack in the member role. master - I/O module has stacking capability and is part of a stack in the master role. NOTE: The term disabled was changed to the term standby to be more descriptive." ::= { smPowerRestartEntry 23 } smStackingModeInfo OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string containing a text description about the details of which functions are protected for a switch module when it is in Stacking Mode as Master or Member. The possible functions protected by switch modules are IP configuration, External Port Access, External Management all over ports and Restore to defaults." ::= { smPowerRestartEntry 24 } smIOCompatibilityTable OBJECT-TYPE SYNTAX SEQUENCE OF SmIOCompatibilityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module control table." ::= { switchModuleControl 10 } smIOCompatibilityEntry OBJECT-TYPE SYNTAX SmIOCompatibilityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module IO compatibility table entry" INDEX { smIOCompatibilityIndex } ::= { smIOCompatibilityTable 1 } SmIOCompatibilityEntry ::= SEQUENCE { smIOCompatibilityIndex INTEGER, smIOCompatibilityId INTEGER, smIOCompatibilityModuleBay OCTET STRING, smIOCompatibilityModulePower OCTET STRING, smIOCompatibilityModuleFabricType OCTET STRING, smIOCompatibilityStatus OCTET STRING } smIOCompatibilityIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module IO compatibility index." ::= { smIOCompatibilityEntry 1 } smIOCompatibilityId OBJECT-TYPE SYNTAX INTEGER { module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The switch module numeric identifier." ::= { smIOCompatibilityEntry 2 } smIOCompatibilityModuleBay OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The modules (each one specified by module type and bay number) that this I/O module can communicate with over the midplane networking fabric (i.e. a physical path exists between the I/O module and this module)." ::= { smIOCompatibilityEntry 3 } smIOCompatibilityModulePower OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The power state of the module specified in smIOCompatibilityModuleBay." ::= { smIOCompatibilityEntry 4 } smIOCompatibilityModuleFabricType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The I/O fabric type on the module side for the module. 'n/a' will be displayed if the corresponding channel is not populated on the module side (e.g. we are looking at the details for an Infiniband switch but the blade does not have an Infiniband expansion card attached in the corresponding expansion slot)." ::= { smIOCompatibilityEntry 5 } smIOCompatibilityStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The compatibility status for this I/O module and the module specified in smIOCompatibilityModuleBay. The possible values are: OK: No compatibility issues n/a: Indicates the corresponding channel is not populated on the module side even though the module is present (e.g. we are looking at the details for an Infiniband switch but the blade specified in smIOCompatibilityModuleBay does not have an Infiniband expansion card attached in the corresponding expansion slot). Attention: Indicates one of the following: The module specified in smIOCompatibilityModuleBay has a communication error. The I/O module is powered off but the module specified in smIOCompatibilityModuleBay is powered on. Mismatch: Indicates one of the following cases:: Fabric types are incompatible Unknown fabric type on the module side Unknown I/O module type" ::= { smIOCompatibilityEntry 6 } -- ******************************************************************************** -- Switch module config -- ******************************************************************************** switchModuleConfig OBJECT IDENTIFIER ::= { switchModule 2 } -- Server blade switch module configuration switchMgmtNetworkCfg OBJECT IDENTIFIER ::= { switchModuleConfig 1 } -- Server blade switch module management network config -- -- Current switch module network config -- switchCurrentNwCfg OBJECT IDENTIFIER ::= { switchMgmtNetworkCfg 1 } -- Server blade switch module current network config smCurrentIPInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF SmCurrentIPInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module current IP information. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected." ::= { switchCurrentNwCfg 1 } smCurrentIPInfoEntry OBJECT-TYPE SYNTAX SmCurrentIPInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module current IP table entry. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected." INDEX { smCurrentIPInfoIndex } ::= { smCurrentIPInfoTable 1 } SmCurrentIPInfoEntry ::= SEQUENCE { smCurrentIPInfoIndex INTEGER, smCurrentIPInfoId INTEGER, smCurrentIPInfoExists INTEGER, smCurrentIPInfoPowerState INTEGER, smCurrentIPAddr IpAddress, smCurrentSubnetMask IpAddress, smCurrentGateway IpAddress, smCurrentIPConfigMethod INTEGER } smCurrentIPInfoIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module current IP info index. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected." ::= { smCurrentIPInfoEntry 1 } smCurrentIPInfoId OBJECT-TYPE SYNTAX INTEGER { module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The switch module numeric identifier. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected." ::= { smCurrentIPInfoEntry 2 } smCurrentIPInfoExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module specified exists or not. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected." ::= { smCurrentIPInfoEntry 3 } smCurrentIPInfoPowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), shutdownInProgress(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the I/O Module specified is powered on or not. The value 'shutdownInProgress' is for the I/O Module that may take some time to transition from 'poweron' to 'poweroff'. Such as SAS Controller Modules, that must flush pending I/O before powering off in order to maintain data integrity. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected." ::= { smCurrentIPInfoEntry 4 } smCurrentIPAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The switch module current IP address. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected." ::= { smCurrentIPInfoEntry 6 } smCurrentSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The switch module current subnet mask. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected." ::= { smCurrentIPInfoEntry 7 } smCurrentGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The switch module current IP gateway. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected." ::= { smCurrentIPInfoEntry 8 } smCurrentIPConfigMethod OBJECT-TYPE SYNTAX INTEGER { unknown(0), static(1), dhcp(2), nat (3), bootp(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The switch module current IP configuration method. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected." ::= { smCurrentIPInfoEntry 9 } -- ******************************************************************************** -- New switch module network config -- ******************************************************************************** switchNewNwCfg OBJECT IDENTIFIER ::= { switchMgmtNetworkCfg 2 } -- Server blade switch module new network config smNewIPInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF SmNewIPInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module new IP information. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected." ::= { switchNewNwCfg 1 } smNewIPInfoEntry OBJECT-TYPE SYNTAX SmNewIPInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module new IP configuration information table entry. NOTE: This MIB table is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected." INDEX { smNewIPInfoIndex } ::= { smNewIPInfoTable 1 } SmNewIPInfoEntry ::= SEQUENCE { smNewIPInfoIndex INTEGER, smNewIPInfoId INTEGER, smNewIPInfoExists INTEGER, smNewIPInfoPowerState INTEGER, smNewIPAddr IpAddress, smNewSubnetMask IpAddress, smNewGateway IpAddress, smNewIPConfigMethod INTEGER, smNewIPConfigEnableDisable INTEGER } smNewIPInfoIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module new IP info index. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected." ::= { smNewIPInfoEntry 1 } smNewIPInfoId OBJECT-TYPE SYNTAX INTEGER { module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The switch module numeric identifier. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected." ::= { smNewIPInfoEntry 2 } smNewIPInfoExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module specified exists or not. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected." ::= { smNewIPInfoEntry 3 } smNewIPInfoPowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module specified is powered on or not. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode and IP configuration is protected.." ::= { smNewIPInfoEntry 4 } smNewIPAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The switch module new IP address. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode." ::= { smNewIPInfoEntry 6 } smNewSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The switch module new subnet mask. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode." ::= { smNewIPInfoEntry 7 } smNewGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The switch module new IP gateway. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode." ::= { smNewIPInfoEntry 8 } smNewIPConfigMethod OBJECT-TYPE SYNTAX INTEGER { unknown(0), static(1), dhcp(2), nat(3), bootp(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The switch module new IP configuration method. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode." ::= { smNewIPInfoEntry 9 } smNewIPConfigEnableDisable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "A set command enables a new IP configuration that has been previously defined. A get command indicates whether the new IP configuration information has been enabled. NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode permission and the switch module goes into Protected Mode. NOTE: This MIB object can not be set if the switch module is in Stacking Mode, and IP Configuration is protected. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode." ::= { smNewIPInfoEntry 10 } -- ******************************************************************************** -- Network protocol (Network Address Translation) config -- ******************************************************************************** switchNwProtCfg OBJECT IDENTIFIER ::= { switchMgmtNetworkCfg 3 } switchNwProtCfgModOne OBJECT IDENTIFIER ::= { switchNwProtCfg 1 } smNwProtInfoModOneTable OBJECT-TYPE SYNTAX SEQUENCE OF SmNwProtInfoModOneEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 1 network protocol (Network Address Translation) information." ::= { switchNwProtCfgModOne 1 } smNwProtInfoModOneEntry OBJECT-TYPE SYNTAX SmNwProtInfoModOneEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 1 network protocol (Network Address Translation) configuration information table entry" INDEX { smNwProtInfoModOneIndex } ::= { smNwProtInfoModOneTable 1 } SmNwProtInfoModOneEntry ::= SEQUENCE { smNwProtInfoModOneIndex INTEGER, smNwProtInfoModOneId INTEGER, smNwProtInfoModOneExists INTEGER, smNwProtInfoModOnePowerState INTEGER, smNwProtInfoModOneProtName OCTET STRING, smNwProtInfoModOneProtID INTEGER, smNwProtInfoModOneExtPort INTEGER, smNwProtInfoModOneIntPort INTEGER, smNwProtInfoModOneEnable INTEGER } smNwProtInfoModOneIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module 1 network protocol (Network Address Translation) information index." ::= { smNwProtInfoModOneEntry 1 } smNwProtInfoModOneId OBJECT-TYPE SYNTAX INTEGER { module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The switch module 1 numeric identifier." ::= { smNwProtInfoModOneEntry 2 } smNwProtInfoModOneExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 1 exists or not." ::= { smNwProtInfoModOneEntry 3 } smNwProtInfoModOnePowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 1 is powered on or not." ::= { smNwProtInfoModOneEntry 4 } smNwProtInfoModOneProtName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Protocol name" ::= { smNwProtInfoModOneEntry 5 } smNwProtInfoModOneProtID OBJECT-TYPE SYNTAX INTEGER { -- ip(1), tcp(2), udp(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Protocol ID" ::= { smNwProtInfoModOneEntry 6 } smNwProtInfoModOneExtPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "External port" ::= { smNwProtInfoModOneEntry 7 } smNwProtInfoModOneIntPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Internal port." ::= { smNwProtInfoModOneEntry 8 } smNwProtInfoModOneEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the protocol entry." ::= { smNwProtInfoModOneEntry 9 } smNwProtInfoModOneActivate OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModOne 2 } smNwProtInfoModOneReset OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModOne 3 } switchNwProtCfgModTwo OBJECT IDENTIFIER ::= { switchNwProtCfg 2 } smNwProtInfoModTwoTable OBJECT-TYPE SYNTAX SEQUENCE OF SmNwProtInfoModTwoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 2 network protocol (Network Address Translation) information." ::= { switchNwProtCfgModTwo 1 } smNwProtInfoModTwoEntry OBJECT-TYPE SYNTAX SmNwProtInfoModTwoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 2 network protocol (Network Address Translation) configuration information table entry" INDEX { smNwProtInfoModTwoIndex } ::= { smNwProtInfoModTwoTable 1 } SmNwProtInfoModTwoEntry ::= SEQUENCE { smNwProtInfoModTwoIndex INTEGER, smNwProtInfoModTwoId INTEGER, smNwProtInfoModTwoExists INTEGER, smNwProtInfoModTwoPowerState INTEGER, smNwProtInfoModTwoProtName OCTET STRING, smNwProtInfoModTwoProtID INTEGER, smNwProtInfoModTwoExtPort INTEGER, smNwProtInfoModTwoIntPort INTEGER, smNwProtInfoModTwoEnable INTEGER } smNwProtInfoModTwoIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module 2 network protocol (Network Address Translation) information index." ::= { smNwProtInfoModTwoEntry 1 } smNwProtInfoModTwoId OBJECT-TYPE SYNTAX INTEGER { module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The switch module 2 numeric identifier." ::= { smNwProtInfoModTwoEntry 2 } smNwProtInfoModTwoExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 2 exists or not." ::= { smNwProtInfoModTwoEntry 3 } smNwProtInfoModTwoPowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 2 is powered on or not." ::= { smNwProtInfoModTwoEntry 4 } smNwProtInfoModTwoProtName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Protocol name" ::= { smNwProtInfoModTwoEntry 5 } smNwProtInfoModTwoProtID OBJECT-TYPE SYNTAX INTEGER { tcp(2), udp(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Protocol ID" ::= { smNwProtInfoModTwoEntry 6 } smNwProtInfoModTwoExtPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "External port" ::= { smNwProtInfoModTwoEntry 7 } smNwProtInfoModTwoIntPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Internal port." ::= { smNwProtInfoModTwoEntry 8 } smNwProtInfoModTwoEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the protocol entry." ::= { smNwProtInfoModTwoEntry 9 } smNwProtInfoModTwoActivate OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModTwo 2 } smNwProtInfoModTwoReset OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModTwo 3 } switchNwProtCfgModThree OBJECT IDENTIFIER ::= { switchNwProtCfg 3 } smNwProtInfoModThreeTable OBJECT-TYPE SYNTAX SEQUENCE OF SmNwProtInfoModThreeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 3 network protocol (Network Address Translation) information." ::= { switchNwProtCfgModThree 1 } smNwProtInfoModThreeEntry OBJECT-TYPE SYNTAX SmNwProtInfoModThreeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 3 network protocol (Network Address Translation) configuration information table entry" INDEX { smNwProtInfoModThreeIndex } ::= { smNwProtInfoModThreeTable 1 } SmNwProtInfoModThreeEntry ::= SEQUENCE { smNwProtInfoModThreeIndex INTEGER, smNwProtInfoModThreeId INTEGER, smNwProtInfoModThreeExists INTEGER, smNwProtInfoModThreePowerState INTEGER, smNwProtInfoModThreeProtName OCTET STRING, smNwProtInfoModThreeProtID INTEGER, smNwProtInfoModThreeExtPort INTEGER, smNwProtInfoModThreeIntPort INTEGER, smNwProtInfoModThreeEnable INTEGER } smNwProtInfoModThreeIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module 3 network protocol (Network Address Translation) information index." ::= { smNwProtInfoModThreeEntry 1 } smNwProtInfoModThreeId OBJECT-TYPE SYNTAX INTEGER { module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The switch module 3 numeric identifier." ::= { smNwProtInfoModThreeEntry 2 } smNwProtInfoModThreeExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 3 exists or not." ::= { smNwProtInfoModThreeEntry 3 } smNwProtInfoModThreePowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 3 is powered on or not." ::= { smNwProtInfoModThreeEntry 4 } smNwProtInfoModThreeProtName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Protocol name" ::= { smNwProtInfoModThreeEntry 5 } smNwProtInfoModThreeProtID OBJECT-TYPE SYNTAX INTEGER { tcp(2), udp(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Protocol ID" ::= { smNwProtInfoModThreeEntry 6 } smNwProtInfoModThreeExtPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "External port" ::= { smNwProtInfoModThreeEntry 7 } smNwProtInfoModThreeIntPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Internal port." ::= { smNwProtInfoModThreeEntry 8 } smNwProtInfoModThreeEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the protocol entry." ::= { smNwProtInfoModThreeEntry 9 } smNwProtInfoModThreeActivate OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModThree 2 } smNwProtInfoModThreeReset OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModThree 3 } switchNwProtCfgModFour OBJECT IDENTIFIER ::= { switchNwProtCfg 4 } smNwProtInfoModFourTable OBJECT-TYPE SYNTAX SEQUENCE OF SmNwProtInfoModFourEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 4 network protocol (Network Address Translation) information." ::= { switchNwProtCfgModFour 1 } smNwProtInfoModFourEntry OBJECT-TYPE SYNTAX SmNwProtInfoModFourEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 3 network protocol (Network Address Translation) configuration information table entry." INDEX { smNwProtInfoModFourIndex } ::= { smNwProtInfoModFourTable 1 } SmNwProtInfoModFourEntry ::= SEQUENCE { smNwProtInfoModFourIndex INTEGER, smNwProtInfoModFourId INTEGER, smNwProtInfoModFourExists INTEGER, smNwProtInfoModFourPowerState INTEGER, smNwProtInfoModFourProtName OCTET STRING, smNwProtInfoModFourProtID INTEGER, smNwProtInfoModFourExtPort INTEGER, smNwProtInfoModFourIntPort INTEGER, smNwProtInfoModFourEnable INTEGER } smNwProtInfoModFourIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module 4 network protocol (Network Address Translation) information index." ::= { smNwProtInfoModFourEntry 1 } smNwProtInfoModFourId OBJECT-TYPE SYNTAX INTEGER { module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The switch module 4 numeric identifier." ::= { smNwProtInfoModFourEntry 2 } smNwProtInfoModFourExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 4 exists or not." ::= { smNwProtInfoModFourEntry 3 } smNwProtInfoModFourPowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 4 is powered on or not." ::= { smNwProtInfoModFourEntry 4 } smNwProtInfoModFourProtName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Protocol name" ::= { smNwProtInfoModFourEntry 5 } smNwProtInfoModFourProtID OBJECT-TYPE SYNTAX INTEGER { tcp(2), udp(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Protocol ID" ::= { smNwProtInfoModFourEntry 6 } smNwProtInfoModFourExtPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "External port" ::= { smNwProtInfoModFourEntry 7 } smNwProtInfoModFourIntPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Internal port." ::= { smNwProtInfoModFourEntry 8 } smNwProtInfoModFourEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the protocol entry." ::= { smNwProtInfoModFourEntry 9 } smNwProtInfoModFourActivate OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModFour 2 } smNwProtInfoModFourReset OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModFour 3 } switchNwProtCfgModFive OBJECT IDENTIFIER ::= { switchNwProtCfg 5 } smNwProtInfoModFiveTable OBJECT-TYPE SYNTAX SEQUENCE OF SmNwProtInfoModFiveEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 5 network protocol (Network Address Translation) information." ::= { switchNwProtCfgModFive 1 } smNwProtInfoModFiveEntry OBJECT-TYPE SYNTAX SmNwProtInfoModFiveEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 5 network protocol (Network Address Translation) configuration information table entry" INDEX { smNwProtInfoModFiveIndex } ::= { smNwProtInfoModFiveTable 1 } SmNwProtInfoModFiveEntry ::= SEQUENCE { smNwProtInfoModFiveIndex INTEGER, smNwProtInfoModFiveId INTEGER, smNwProtInfoModFiveExists INTEGER, smNwProtInfoModFivePowerState INTEGER, smNwProtInfoModFiveProtName OCTET STRING, smNwProtInfoModFiveProtID INTEGER, smNwProtInfoModFiveExtPort INTEGER, smNwProtInfoModFiveIntPort INTEGER, smNwProtInfoModFiveEnable INTEGER } smNwProtInfoModFiveIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module 5 network protocol (Network Address Translation) information index." ::= { smNwProtInfoModFiveEntry 1 } smNwProtInfoModFiveId OBJECT-TYPE SYNTAX INTEGER { module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The switch module 5 numeric identifier." ::= { smNwProtInfoModFiveEntry 2 } smNwProtInfoModFiveExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 5 exists or not." ::= { smNwProtInfoModFiveEntry 3 } smNwProtInfoModFivePowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 5 is powered on or not." ::= { smNwProtInfoModFiveEntry 4 } smNwProtInfoModFiveProtName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Protocol name" ::= { smNwProtInfoModFiveEntry 5 } smNwProtInfoModFiveProtID OBJECT-TYPE SYNTAX INTEGER { tcp(2), udp(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Protocol ID" ::= { smNwProtInfoModFiveEntry 6 } smNwProtInfoModFiveExtPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "External port" ::= { smNwProtInfoModFiveEntry 7 } smNwProtInfoModFiveIntPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Internal port." ::= { smNwProtInfoModFiveEntry 8 } smNwProtInfoModFiveEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the protocol entry." ::= { smNwProtInfoModFiveEntry 9 } smNwProtInfoModFiveActivate OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModFive 2 } smNwProtInfoModFiveReset OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModFive 3 } switchNwProtCfgModSix OBJECT IDENTIFIER ::= { switchNwProtCfg 6 } smNwProtInfoModSixTable OBJECT-TYPE SYNTAX SEQUENCE OF SmNwProtInfoModSixEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 6 network protocol (Network Address Translation) information." ::= { switchNwProtCfgModSix 1 } smNwProtInfoModSixEntry OBJECT-TYPE SYNTAX SmNwProtInfoModSixEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 6 network protocol (Network Address Translation) configuration information table entry" INDEX { smNwProtInfoModSixIndex } ::= { smNwProtInfoModSixTable 1 } SmNwProtInfoModSixEntry ::= SEQUENCE { smNwProtInfoModSixIndex INTEGER, smNwProtInfoModSixId INTEGER, smNwProtInfoModSixExists INTEGER, smNwProtInfoModSixPowerState INTEGER, smNwProtInfoModSixProtName OCTET STRING, smNwProtInfoModSixProtID INTEGER, smNwProtInfoModSixExtPort INTEGER, smNwProtInfoModSixIntPort INTEGER, smNwProtInfoModSixEnable INTEGER } smNwProtInfoModSixIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module 6 network protocol (Network Address Translation) information index." ::= { smNwProtInfoModSixEntry 1 } smNwProtInfoModSixId OBJECT-TYPE SYNTAX INTEGER { module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The switch module 6 numeric identifier." ::= { smNwProtInfoModSixEntry 2 } smNwProtInfoModSixExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 6 exists or not." ::= { smNwProtInfoModSixEntry 3 } smNwProtInfoModSixPowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 6 is powered on or not." ::= { smNwProtInfoModSixEntry 4 } smNwProtInfoModSixProtName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Protocol name" ::= { smNwProtInfoModSixEntry 5 } smNwProtInfoModSixProtID OBJECT-TYPE SYNTAX INTEGER { tcp(2), udp(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Protocol ID" ::= { smNwProtInfoModSixEntry 6 } smNwProtInfoModSixExtPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "External port" ::= { smNwProtInfoModSixEntry 7 } smNwProtInfoModSixIntPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Internal port." ::= { smNwProtInfoModSixEntry 8 } smNwProtInfoModSixEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the protocol entry." ::= { smNwProtInfoModSixEntry 9 } smNwProtInfoModSixActivate OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModSix 2 } smNwProtInfoModSixReset OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModSix 3 } switchNwProtCfgModSeven OBJECT IDENTIFIER ::= { switchNwProtCfg 7 } smNwProtInfoModSevenTable OBJECT-TYPE SYNTAX SEQUENCE OF SmNwProtInfoModSevenEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 7 network protocol (Network Address Translation) information." ::= { switchNwProtCfgModSeven 1 } smNwProtInfoModSevenEntry OBJECT-TYPE SYNTAX SmNwProtInfoModSevenEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 7 network protocol (Network Address Translation) configuration information table entry" INDEX { smNwProtInfoModSevenIndex } ::= { smNwProtInfoModSevenTable 1 } SmNwProtInfoModSevenEntry ::= SEQUENCE { smNwProtInfoModSevenIndex INTEGER, smNwProtInfoModSevenId INTEGER, smNwProtInfoModSevenExists INTEGER, smNwProtInfoModSevenPowerState INTEGER, smNwProtInfoModSevenProtName OCTET STRING, smNwProtInfoModSevenProtID INTEGER, smNwProtInfoModSevenExtPort INTEGER, smNwProtInfoModSevenIntPort INTEGER, smNwProtInfoModSevenEnable INTEGER } smNwProtInfoModSevenIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module 7 network protocol (Network Address Translation) information index." ::= { smNwProtInfoModSevenEntry 1 } smNwProtInfoModSevenId OBJECT-TYPE SYNTAX INTEGER { module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The switch module 7 numeric identifier." ::= { smNwProtInfoModSevenEntry 2 } smNwProtInfoModSevenExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 7 exists or not." ::= { smNwProtInfoModSevenEntry 3 } smNwProtInfoModSevenPowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 7 is powered on or not." ::= { smNwProtInfoModSevenEntry 4 } smNwProtInfoModSevenProtName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Protocol name" ::= { smNwProtInfoModSevenEntry 5 } smNwProtInfoModSevenProtID OBJECT-TYPE SYNTAX INTEGER { tcp(2), udp(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Protocol ID" ::= { smNwProtInfoModSevenEntry 6 } smNwProtInfoModSevenExtPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "External port" ::= { smNwProtInfoModSevenEntry 7 } smNwProtInfoModSevenIntPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Internal port." ::= { smNwProtInfoModSevenEntry 8 } smNwProtInfoModSevenEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the protocol entry." ::= { smNwProtInfoModSevenEntry 9 } smNwProtInfoModSevenActivate OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModSeven 2 } smNwProtInfoModSevenReset OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModSeven 3 } switchNwProtCfgModEight OBJECT IDENTIFIER ::= { switchNwProtCfg 8 } smNwProtInfoModEightTable OBJECT-TYPE SYNTAX SEQUENCE OF SmNwProtInfoModEightEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 8 network protocol (Network Address Translation) information." ::= { switchNwProtCfgModEight 1 } smNwProtInfoModEightEntry OBJECT-TYPE SYNTAX SmNwProtInfoModEightEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 8 network protocol (Network Address Translation) configuration information table entry" INDEX { smNwProtInfoModEightIndex } ::= { smNwProtInfoModEightTable 1 } SmNwProtInfoModEightEntry ::= SEQUENCE { smNwProtInfoModEightIndex INTEGER, smNwProtInfoModEightId INTEGER, smNwProtInfoModEightExists INTEGER, smNwProtInfoModEightPowerState INTEGER, smNwProtInfoModEightProtName OCTET STRING, smNwProtInfoModEightProtID INTEGER, smNwProtInfoModEightExtPort INTEGER, smNwProtInfoModEightIntPort INTEGER, smNwProtInfoModEightEnable INTEGER } smNwProtInfoModEightIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module 8 network protocol (Network Address Translation) information index." ::= { smNwProtInfoModEightEntry 1 } smNwProtInfoModEightId OBJECT-TYPE SYNTAX INTEGER { module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The switch module 8 numeric identifier." ::= { smNwProtInfoModEightEntry 2 } smNwProtInfoModEightExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 8 exists or not." ::= { smNwProtInfoModEightEntry 3 } smNwProtInfoModEightPowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 8 is powered on or not." ::= { smNwProtInfoModEightEntry 4 } smNwProtInfoModEightProtName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Protocol name" ::= { smNwProtInfoModEightEntry 5 } smNwProtInfoModEightProtID OBJECT-TYPE SYNTAX INTEGER { tcp(2), udp(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Protocol ID" ::= { smNwProtInfoModEightEntry 6 } smNwProtInfoModEightExtPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "External port" ::= { smNwProtInfoModEightEntry 7 } smNwProtInfoModEightIntPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Internal port." ::= { smNwProtInfoModEightEntry 8 } smNwProtInfoModEightEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the protocol entry." ::= { smNwProtInfoModEightEntry 9 } smNwProtInfoModEightActivate OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModEight 2 } smNwProtInfoModEightReset OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModEight 3 } switchNwProtCfgModNine OBJECT IDENTIFIER ::= { switchNwProtCfg 9 } smNwProtInfoModNineTable OBJECT-TYPE SYNTAX SEQUENCE OF SmNwProtInfoModNineEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 9 network protocol (Network Address Translation) information." ::= { switchNwProtCfgModNine 1 } smNwProtInfoModNineEntry OBJECT-TYPE SYNTAX SmNwProtInfoModNineEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 9 network protocol (Network Address Translation) configuration information table entry" INDEX { smNwProtInfoModNineIndex } ::= { smNwProtInfoModNineTable 1 } SmNwProtInfoModNineEntry ::= SEQUENCE { smNwProtInfoModNineIndex INTEGER, smNwProtInfoModNineId INTEGER, smNwProtInfoModNineExists INTEGER, smNwProtInfoModNinePowerState INTEGER, smNwProtInfoModNineProtName OCTET STRING, smNwProtInfoModNineProtID INTEGER, smNwProtInfoModNineExtPort INTEGER, smNwProtInfoModNineIntPort INTEGER, smNwProtInfoModNineEnable INTEGER } smNwProtInfoModNineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module 9 network protocol (Network Address Translation) information index." ::= { smNwProtInfoModNineEntry 1 } smNwProtInfoModNineId OBJECT-TYPE SYNTAX INTEGER { module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The switch module 9 numeric identifier." ::= { smNwProtInfoModNineEntry 2 } smNwProtInfoModNineExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 9 exists or not." ::= { smNwProtInfoModNineEntry 3 } smNwProtInfoModNinePowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 9 is powered on or not." ::= { smNwProtInfoModNineEntry 4 } smNwProtInfoModNineProtName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Protocol name" ::= { smNwProtInfoModNineEntry 5 } smNwProtInfoModNineProtID OBJECT-TYPE SYNTAX INTEGER { tcp(2), udp(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Protocol ID" ::= { smNwProtInfoModNineEntry 6 } smNwProtInfoModNineExtPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "External port" ::= { smNwProtInfoModNineEntry 7 } smNwProtInfoModNineIntPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Internal port." ::= { smNwProtInfoModNineEntry 8 } smNwProtInfoModNineEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the protocol entry." ::= { smNwProtInfoModNineEntry 9 } smNwProtInfoModNineActivate OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModNine 2 } smNwProtInfoModNineReset OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModNine 3 } switchNwProtCfgModTen OBJECT IDENTIFIER ::= { switchNwProtCfg 10 } smNwProtInfoModTenTable OBJECT-TYPE SYNTAX SEQUENCE OF SmNwProtInfoModTenEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 10 network protocol (Network Address Translation) information." ::= { switchNwProtCfgModTen 1 } smNwProtInfoModTenEntry OBJECT-TYPE SYNTAX SmNwProtInfoModTenEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch module 10 network protocol (Network Address Translation) configuration information table entry" INDEX { smNwProtInfoModTenIndex } ::= { smNwProtInfoModTenTable 1 } SmNwProtInfoModTenEntry ::= SEQUENCE { smNwProtInfoModTenIndex INTEGER, smNwProtInfoModTenId INTEGER, smNwProtInfoModTenExists INTEGER, smNwProtInfoModTenPowerState INTEGER, smNwProtInfoModTenProtName OCTET STRING, smNwProtInfoModTenProtID INTEGER, smNwProtInfoModTenExtPort INTEGER, smNwProtInfoModTenIntPort INTEGER, smNwProtInfoModTenEnable INTEGER } smNwProtInfoModTenIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module 10 network protocol (Network Address Translation) information index." ::= { smNwProtInfoModTenEntry 1 } smNwProtInfoModTenId OBJECT-TYPE SYNTAX INTEGER { module1(1), module2(2), module3(3), module4(4), module5(5), module6(6), module7(7), module8(8), module9(9), module10(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The switch module 10 numeric identifier." ::= { smNwProtInfoModTenEntry 2 } smNwProtInfoModTenExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 10 exists or not." ::= { smNwProtInfoModTenEntry 3 } smNwProtInfoModTenPowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the switch module 10 is powered on or not." ::= { smNwProtInfoModTenEntry 4 } smNwProtInfoModTenProtName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Protocol name" ::= { smNwProtInfoModTenEntry 5 } smNwProtInfoModTenProtID OBJECT-TYPE SYNTAX INTEGER { tcp(2), udp(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Protocol ID" ::= { smNwProtInfoModTenEntry 6 } smNwProtInfoModTenExtPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "External port" ::= { smNwProtInfoModTenEntry 7 } smNwProtInfoModTenIntPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Internal port." ::= { smNwProtInfoModTenEntry 8 } smNwProtInfoModTenEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the protocol entry." ::= { smNwProtInfoModTenEntry 9 } smNwProtInfoModTenActivate OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Activate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModTen 2 } smNwProtInfoModTenReset OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { switchNwProtCfgModTen 3 } switchIPv6Config OBJECT IDENTIFIER ::= { switchMgmtNetworkCfg 4 } smIPv6ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SmIPv6ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of IPv6 configuration options for switch modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6." ::= { switchIPv6Config 1 } smIPv6ConfigEntry OBJECT-TYPE SYNTAX SmIPv6ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "IPv6 configuration options for a switch module.. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6." INDEX { smIPv6ConfigIndex } ::= { smIPv6ConfigTable 1 } SmIPv6ConfigEntry ::= SEQUENCE { smIPv6ConfigIndex INTEGER, smIPv6ConfigEnabled INTEGER, smIPv6ConfigStatic INTEGER, smDHCPv6ConfigEnabled INTEGER, smIPv6ConfigStatelessEnabled INTEGER } smIPv6ConfigIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The switch module's slot number" ::= { smIPv6ConfigEntry 1 } smIPv6ConfigEnabled OBJECT-TYPE SYNTAX INTEGER { disable(0),enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables/Disables IPv6 support on the switch module." ::= { smIPv6ConfigEntry 2 } smIPv6ConfigStatic OBJECT-TYPE SYNTAX INTEGER { disable(0),enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables/Disables IPv6 static configuration support on the switch module." ::= { smIPv6ConfigEntry 3 } smDHCPv6ConfigEnabled OBJECT-TYPE SYNTAX INTEGER { disable(0),enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables/Disables DHCPv6 address configuration support on the switch module." ::= { smIPv6ConfigEntry 4 } smIPv6ConfigStatelessEnabled OBJECT-TYPE SYNTAX INTEGER { disable(0),enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables/Disables IPv6 stateless auto-configuration support on the switch module." ::= { smIPv6ConfigEntry 5 } smIPv6AddressTable OBJECT-TYPE SYNTAX SEQUENCE OF SmIPv6AddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of assigned IPv6 addresses for switch modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6." ::= { switchIPv6Config 2 } smIPv6AddressEntry OBJECT-TYPE SYNTAX SmIPv6AddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The assigned IPv6 address for a given switch module NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6." INDEX { smIPv6AddressIndex, smIPv6AddressEntryIndex} ::= { smIPv6AddressTable 1 } SmIPv6AddressEntry ::= SEQUENCE { smIPv6AddressIndex INTEGER, smIPv6AddressEntryIndex INTEGER, smIPv6AddressType INTEGER, smIPv6Address InetAddressIPv6, smIPv6AddressPrefixLen INTEGER, smIPv6AddressDefaultRoute InetAddressIPv6 } smIPv6AddressIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The switch module's slot number" ::= { smIPv6AddressEntry 1 } smIPv6AddressEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The switch module's address entry index" ::= { smIPv6AddressEntry 2 } smIPv6AddressType OBJECT-TYPE SYNTAX INTEGER { static(1), dhcp6(2), link-local(3), autconfig(4), configured-static(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The address type." ::= { smIPv6AddressEntry 3 } smIPv6Address OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-only STATUS mandatory DESCRIPTION "The assigned IPv6 address" ::= { smIPv6AddressEntry 4 } smIPv6AddressPrefixLen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The prefix length for the given address." ::= { smIPv6AddressEntry 5 } smIPv6AddressDefaultRoute OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-only STATUS mandatory DESCRIPTION "The default route used for the given address" ::= { smIPv6AddressEntry 6 } smIPv6StaticConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SmIPv6StaticConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Allows configuration of static IPv6 information for supported IO modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6." ::= { switchIPv6Config 3 } smIPv6StaticConfigEntry OBJECT-TYPE SYNTAX SmIPv6StaticConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The static IP address assignment information for an IO module. Once the assignement has taken place the address will show up as a row in the smIPv6AddressTable NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected. NOTE: This MIB object is not applicable to modules that do not support IPv6." INDEX { smIPv6StaticIndex} ::= { smIPv6StaticConfigTable 1 } SmIPv6StaticConfigEntry ::= SEQUENCE { smIPv6StaticIndex INTEGER, smIPv6StaticAddress InetAddressIPv6, smIPv6StaticAddressPrefixLen INTEGER, smIPv6StaticAddressDefaultRoute InetAddressIPv6 } smIPv6StaticIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The switch module's slot number" ::= { smIPv6StaticConfigEntry 1 } smIPv6StaticAddress OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-write STATUS mandatory DESCRIPTION "The assigned IPv6 address. NOTE: If changing with smIPv6StaticAddressPrefixLen and/or smIPv6StaticAddressDefaultRoute sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting." ::= { smIPv6StaticConfigEntry 2 } smIPv6StaticAddressPrefixLen OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The prefix length for the given address. NOTE: If changing with smIPv6StaticAddress and/or smIPv6StaticAddressDefaultRoute sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting." ::= { smIPv6StaticConfigEntry 3 } smIPv6StaticAddressDefaultRoute OBJECT-TYPE SYNTAX InetAddressIPv6 ACCESS read-write STATUS mandatory DESCRIPTION "The default route used for the given address NOTE: If changing with smIPv6StaticAddressPrefixLen and/or smIPv6StaticAddress sending the update as a single SET command(in one PDU) will minimize the potential downtime of the target switch. NOTE: Sets on this object can take a few seconds. You may need to update your SNMP timeout when modifying this setting." ::= { smIPv6StaticConfigEntry 4 } -- ******************************************************************************** -- Switch module port tables -- ******************************************************************************** switchPortCfg OBJECT IDENTIFIER ::= { switchModuleConfig 2 } switchModOnePortCfg OBJECT IDENTIFIER ::= { switchPortCfg 1 } smOnePortCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF SmOnePortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 1 port configuration information. NOTE: This option is not supported on all I/O modules." ::= { switchModOnePortCfg 1 } smOnePortCfgEntry OBJECT-TYPE SYNTAX SmOnePortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 1 port configuration information table entry" INDEX { smOnePortCfgIndex } ::= { smOnePortCfgTable 1 } SmOnePortCfgEntry ::= SEQUENCE { smOnePortCfgIndex INTEGER, smOnePortCfgLabel OCTET STRING, smOnePortCfgType INTEGER, smOnePortCfgLinkSetting INTEGER, smOnePortCfgLinkState INTEGER, smOnePortCfgSpeedSetting OCTET STRING, smOnePortCfgSpeedStatus OCTET STRING, smOnePortCfgAvailSpeeds OCTET STRING, smOnePortCfgMedia INTEGER, smOnePortCfgProtocol INTEGER, smOnePortCfgWidth INTEGER, smOnePortCfgCableLength INTEGER, smOnePortCfgCableType OCTET STRING, smOnePortCfgVendorName OCTET STRING, smOnePortCfgCompatibility INTEGER, smOnePortCfgDataRate INTEGER } smOnePortCfgIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 1 port sequence index." ::= { smOnePortCfgEntry 1 } smOnePortCfgLabel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 1 port label" ::= { smOnePortCfgEntry 2 } smOnePortCfgType OBJECT-TYPE SYNTAX INTEGER { unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11) } ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 1 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type." ::= { smOnePortCfgEntry 3 } smOnePortCfgLinkSetting OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Current port link setting for Switch Module 1." ::= { smOnePortCfgEntry 4 } smOnePortCfgLinkState OBJECT-TYPE SYNTAX INTEGER { down(0), up(1), initialized(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Current port link state of Switch Module 1." ::= { smOnePortCfgEntry 5 } smOnePortCfgSpeedSetting OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set the port speed using the data rate and duplex value. For examples: 100mf: 100 Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smOnePortCfgAvailSpeeds object are applicable to setting this mib object." ::= { smOnePortCfgEntry 6 } smOnePortCfgSpeedStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Current port speed of Switch Module 1." ::= { smOnePortCfgEntry 7 } smOnePortCfgAvailSpeeds OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Available speed setting per port for Switch Module 1. If there is more than one setting, the speeds are separated by a comma and then a space." ::= { smOnePortCfgEntry 8 } smOnePortCfgMedia OBJECT-TYPE SYNTAX INTEGER { copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port media type of Switch Module 1." ::= { smOnePortCfgEntry 9 } smOnePortCfgProtocol OBJECT-TYPE SYNTAX INTEGER { ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port protocol of Switch Module 1." ::= { smOnePortCfgEntry 10 } smOnePortCfgWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The width of the port in terms of how many combined cables are present for Switch Module 1. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count." ::= { smOnePortCfgEntry 11 } smOnePortCfgCableLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The length (in meters) of the cable supported by this port for Switch Module 1. A value of 0 indicates this field is not applicable to the switch ports." ::= { smOnePortCfgEntry 12 } smOnePortCfgCableType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "External cable type for this port, for example, active copper or passive fiber." ::= { smOnePortCfgEntry 13 } smOnePortCfgVendorName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The cable manufacturer." ::= { smOnePortCfgEntry 14 } smOnePortCfgCompatibility OBJECT-TYPE SYNTAX INTEGER { incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Compatibility of the external cable that is plugged into the port." ::= { smOnePortCfgEntry 15 } smOnePortCfgDataRate OBJECT-TYPE SYNTAX INTEGER { sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Data rate supported for this port." ::= { smOnePortCfgEntry 16 } switchModTwoPortCfg OBJECT IDENTIFIER ::= { switchPortCfg 2 } smTwoPortCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF SmTwoPortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 2 port configuration information. Note: This option is not supported on all I/O modules." ::= { switchModTwoPortCfg 1 } smTwoPortCfgEntry OBJECT-TYPE SYNTAX SmTwoPortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 2 port configuration information table entry" INDEX { smTwoPortCfgIndex } ::= { smTwoPortCfgTable 1 } SmTwoPortCfgEntry ::= SEQUENCE { smTwoPortCfgIndex INTEGER, smTwoPortCfgLabel OCTET STRING, smTwoPortCfgType INTEGER, smTwoPortCfgLinkSetting INTEGER, smTwoPortCfgLinkState INTEGER, smTwoPortCfgSpeedSetting OCTET STRING, smTwoPortCfgSpeedStatus OCTET STRING, smTwoPortCfgAvailSpeeds OCTET STRING, smTwoPortCfgMedia INTEGER, smTwoPortCfgProtocol INTEGER, smTwoPortCfgWidth INTEGER, smTwoPortCfgCableLength INTEGER, smTwoPortCfgCableType OCTET STRING, smTwoPortCfgVendorName OCTET STRING, smTwoPortCfgCompatibility INTEGER, smTwoPortCfgDataRate INTEGER } smTwoPortCfgIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 2 port sequence index." ::= { smTwoPortCfgEntry 1 } smTwoPortCfgLabel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 2 port label" ::= { smTwoPortCfgEntry 2 } smTwoPortCfgType OBJECT-TYPE SYNTAX INTEGER { unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11) } ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 2 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type." ::= { smTwoPortCfgEntry 3 } smTwoPortCfgLinkSetting OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Current port link setting for Switch Module 2." ::= { smTwoPortCfgEntry 4 } smTwoPortCfgLinkState OBJECT-TYPE SYNTAX INTEGER { down(0), up(1), initialized(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Current port link state of Switch Module 2." ::= { smTwoPortCfgEntry 5 } smTwoPortCfgSpeedSetting OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smTwoPortCfgAvailSpeeds are applicable to setting this mib object." ::= { smTwoPortCfgEntry 6 } smTwoPortCfgSpeedStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Current port speed of Switch Module 2." ::= { smTwoPortCfgEntry 7 } smTwoPortCfgAvailSpeeds OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Available speed setting per port for Switch Module 2. If there is more than one setting, the speeds are separated by a comma and then a space." ::= { smTwoPortCfgEntry 8 } smTwoPortCfgMedia OBJECT-TYPE SYNTAX INTEGER { copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port media type of Switch Module 2." ::= { smTwoPortCfgEntry 9 } smTwoPortCfgProtocol OBJECT-TYPE SYNTAX INTEGER { ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port protocol of Switch Module 2." ::= { smTwoPortCfgEntry 10 } smTwoPortCfgWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The width of the port in terms of how many combined cables are present for Switch Module 2. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count." ::= { smTwoPortCfgEntry 11 } smTwoPortCfgCableLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The length (in meters) of the cable supported by this port for Switch Module 2. A value of 0 indicates this field is not applicable to the switch ports." ::= { smTwoPortCfgEntry 12 } smTwoPortCfgCableType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "External cable type for this port, for example, active copper or passive fiber." ::= { smTwoPortCfgEntry 13 } smTwoPortCfgVendorName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The cable manufacturer." ::= { smTwoPortCfgEntry 14 } smTwoPortCfgCompatibility OBJECT-TYPE SYNTAX INTEGER { incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Compatibility of the external cable that is plugged into the port." ::= { smTwoPortCfgEntry 15 } smTwoPortCfgDataRate OBJECT-TYPE SYNTAX INTEGER { sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Data rate supported for this port." ::= { smTwoPortCfgEntry 16 } switchModThreePortCfg OBJECT IDENTIFIER ::= { switchPortCfg 3 } smThreePortCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF SmThreePortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 3 port configuration information. Note: This option is not supported on all I/O modules." ::= { switchModThreePortCfg 1 } smThreePortCfgEntry OBJECT-TYPE SYNTAX SmThreePortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 3 port configuration information table entry" INDEX { smThreePortCfgIndex } ::= { smThreePortCfgTable 1 } SmThreePortCfgEntry ::= SEQUENCE { smThreePortCfgIndex INTEGER, smThreePortCfgLabel OCTET STRING, smThreePortCfgType INTEGER, smThreePortCfgLinkSetting INTEGER, smThreePortCfgLinkState INTEGER, smThreePortCfgSpeedSetting OCTET STRING, smThreePortCfgSpeedStatus OCTET STRING, smThreePortCfgAvailSpeeds OCTET STRING, smThreePortCfgMedia INTEGER, smThreePortCfgProtocol INTEGER, smThreePortCfgWidth INTEGER, smThreePortCfgCableLength INTEGER, smThreePortCfgCableType OCTET STRING, smThreePortCfgVendorName OCTET STRING, smThreePortCfgCompatibility INTEGER, smThreePortCfgDataRate INTEGER } smThreePortCfgIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 3 port sequence index." ::= { smThreePortCfgEntry 1 } smThreePortCfgLabel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 3 port label" ::= { smThreePortCfgEntry 2 } smThreePortCfgType OBJECT-TYPE SYNTAX INTEGER { unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11) } ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 3 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type." ::= { smThreePortCfgEntry 3 } smThreePortCfgLinkSetting OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Current port link setting for Switch Module 3." ::= { smThreePortCfgEntry 4 } smThreePortCfgLinkState OBJECT-TYPE SYNTAX INTEGER { down(0), up(1), initialized(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Current port link state of Switch Module 3." ::= { smThreePortCfgEntry 5 } smThreePortCfgSpeedSetting OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smThreePortCfgAvailSpeeds are applicable to setting this mib object." ::= { smThreePortCfgEntry 6 } smThreePortCfgSpeedStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Current port speed of Switch Module 3." ::= { smThreePortCfgEntry 7 } smThreePortCfgAvailSpeeds OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Available speed setting per port for Switch Module 3. If there is more than one setting, the speeds are separated by a comma and then a space." ::= { smThreePortCfgEntry 8 } smThreePortCfgMedia OBJECT-TYPE SYNTAX INTEGER { copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port media type of Switch Module 3." ::= { smThreePortCfgEntry 9 } smThreePortCfgProtocol OBJECT-TYPE SYNTAX INTEGER { ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port protocol of Switch Module 3." ::= { smThreePortCfgEntry 10 } smThreePortCfgWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The width of the port in terms of how many combined cables are present for Switch Module 3. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count." ::= { smThreePortCfgEntry 11 } smThreePortCfgCableLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The length (in meters) of the cable supported by this port for Switch Module 3. A value of 0 indicates this field is not applicable to the switch ports." ::= { smThreePortCfgEntry 12 } smThreePortCfgCableType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "External cable type for this port, for example, active copper or passive fiber." ::= { smThreePortCfgEntry 13 } smThreePortCfgVendorName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The cable manufacturer." ::= { smThreePortCfgEntry 14 } smThreePortCfgCompatibility OBJECT-TYPE SYNTAX INTEGER { incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Compatibility of the external cable that is plugged into the port." ::= { smThreePortCfgEntry 15 } smThreePortCfgDataRate OBJECT-TYPE SYNTAX INTEGER { sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Data rate supported for this port." ::= { smThreePortCfgEntry 16 } switchModFourPortCfg OBJECT IDENTIFIER ::= { switchPortCfg 4 } smFourPortCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF SmFourPortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 4 port configuration information. Note: This option is not supported on all I/O modules." ::= { switchModFourPortCfg 1 } smFourPortCfgEntry OBJECT-TYPE SYNTAX SmFourPortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 4 port configuration information table entry" INDEX { smFourPortCfgIndex } ::= { smFourPortCfgTable 1 } SmFourPortCfgEntry ::= SEQUENCE { smFourPortCfgIndex INTEGER, smFourPortCfgLabel OCTET STRING, smFourPortCfgType INTEGER, smFourPortCfgLinkSetting INTEGER, smFourPortCfgLinkState INTEGER, smFourPortCfgSpeedSetting OCTET STRING, smFourPortCfgSpeedStatus OCTET STRING, smFourPortCfgAvailSpeeds OCTET STRING, smFourPortCfgMedia INTEGER, smFourPortCfgProtocol INTEGER, smFourPortCfgWidth INTEGER, smFourPortCfgCableLength INTEGER, smFourPortCfgCableType OCTET STRING, smFourPortCfgVendorName OCTET STRING, smFourPortCfgCompatibility INTEGER, smFourPortCfgDataRate INTEGER } smFourPortCfgIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 4 port sequence index." ::= { smFourPortCfgEntry 1 } smFourPortCfgLabel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 4 port label" ::= { smFourPortCfgEntry 2 } smFourPortCfgType OBJECT-TYPE SYNTAX INTEGER { unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11) } ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 4 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type." ::= { smFourPortCfgEntry 3 } smFourPortCfgLinkSetting OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Current port link setting for Switch Module 4." ::= { smFourPortCfgEntry 4 } smFourPortCfgLinkState OBJECT-TYPE SYNTAX INTEGER { down(0), up(1), initialized(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Current port link state of Switch Module 4." ::= { smFourPortCfgEntry 5 } smFourPortCfgSpeedSetting OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smFourPortCfgAvailSpeeds are applicable to setting this mib object." ::= { smFourPortCfgEntry 6 } smFourPortCfgSpeedStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Current port speed of Switch Module 4." ::= { smFourPortCfgEntry 7 } smFourPortCfgAvailSpeeds OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Available speed setting per port for Switch Module 4. If there is more than one setting, the speeds are separated by a comma and then a space." ::= { smFourPortCfgEntry 8 } smFourPortCfgMedia OBJECT-TYPE SYNTAX INTEGER { copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port media type of Switch Module 4." ::= { smFourPortCfgEntry 9 } smFourPortCfgProtocol OBJECT-TYPE SYNTAX INTEGER { ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port protocol of Switch Module 4." ::= { smFourPortCfgEntry 10 } smFourPortCfgWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The width of the port in terms of how many combined cables are present for Switch Module 4. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count." ::= { smFourPortCfgEntry 11 } smFourPortCfgCableLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The length (in meters) of the cable supported by this port for Switch Module 4. A value of 0 indicates this field is not applicable to the switch ports." ::= { smFourPortCfgEntry 12 } smFourPortCfgCableType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "External cable type for this port, for example, active copper or passive fiber." ::= { smFourPortCfgEntry 13 } smFourPortCfgVendorName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The cable manufacturer." ::= { smFourPortCfgEntry 14 } smFourPortCfgCompatibility OBJECT-TYPE SYNTAX INTEGER { incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Compatibility of the external cable that is plugged into the port." ::= { smFourPortCfgEntry 15 } smFourPortCfgDataRate OBJECT-TYPE SYNTAX INTEGER { sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Data rate supported for this port." ::= { smFourPortCfgEntry 16 } switchModFivePortCfg OBJECT IDENTIFIER ::= { switchPortCfg 5 } smFivePortCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF SmFivePortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 5 port configuration information. Note: This option is not supported on all I/O modules." ::= { switchModFivePortCfg 1 } smFivePortCfgEntry OBJECT-TYPE SYNTAX SmFivePortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 5 port configuration information table entry" INDEX { smFivePortCfgIndex } ::= { smFivePortCfgTable 1 } SmFivePortCfgEntry ::= SEQUENCE { smFivePortCfgIndex INTEGER, smFivePortCfgLabel OCTET STRING, smFivePortCfgType INTEGER, smFivePortCfgLinkSetting INTEGER, smFivePortCfgLinkState INTEGER, smFivePortCfgSpeedSetting OCTET STRING, smFivePortCfgSpeedStatus OCTET STRING, smFivePortCfgAvailSpeeds OCTET STRING, smFivePortCfgMedia INTEGER, smFivePortCfgProtocol INTEGER, smFivePortCfgWidth INTEGER, smFivePortCfgCableLength INTEGER, smFivePortCfgCableType OCTET STRING, smFivePortCfgVendorName OCTET STRING, smFivePortCfgCompatibility INTEGER, smFivePortCfgDataRate INTEGER } smFivePortCfgIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 5 port sequence index." ::= { smFivePortCfgEntry 1 } smFivePortCfgLabel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 5 port label" ::= { smFivePortCfgEntry 2 } smFivePortCfgType OBJECT-TYPE SYNTAX INTEGER { unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11) } ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 5 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type." ::= { smFivePortCfgEntry 3 } smFivePortCfgLinkSetting OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Current port link setting for Switch Module 5." ::= { smFivePortCfgEntry 4 } smFivePortCfgLinkState OBJECT-TYPE SYNTAX INTEGER { down(0), up(1), initialized(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Current port link state of Switch Module 5." ::= { smFivePortCfgEntry 5 } smFivePortCfgSpeedSetting OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smFivePortCfgAvailSpeeds are applicable to setting this mib object." ::= { smFivePortCfgEntry 6 } smFivePortCfgSpeedStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Current port speed of Switch Module 5." ::= { smFivePortCfgEntry 7 } smFivePortCfgAvailSpeeds OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Available speed setting per port for Switch Module 5. If there is more than one setting, the speeds are separated by a comma and then a space." ::= { smFivePortCfgEntry 8 } smFivePortCfgMedia OBJECT-TYPE SYNTAX INTEGER { copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port media type of Switch Module 5." ::= { smFivePortCfgEntry 9 } smFivePortCfgProtocol OBJECT-TYPE SYNTAX INTEGER { ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port protocol of Switch Module 5." ::= { smFivePortCfgEntry 10 } smFivePortCfgWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The width of the port in terms of how many combined cables are present for Switch Module 5. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count." ::= { smFivePortCfgEntry 11 } smFivePortCfgCableLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The length (in meters) of the cable supported by this port for Switch Module 5. A value of 0 indicates this field is not applicable to the switch ports." ::= { smFivePortCfgEntry 12 } smFivePortCfgCableType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "External cable type for this port, for example, active copper or passive fiber." ::= { smFivePortCfgEntry 13 } smFivePortCfgVendorName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The cable manufacturer." ::= { smFivePortCfgEntry 14 } smFivePortCfgCompatibility OBJECT-TYPE SYNTAX INTEGER { incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Compatibility of the external cable that is plugged into the port." ::= { smFivePortCfgEntry 15 } smFivePortCfgDataRate OBJECT-TYPE SYNTAX INTEGER { sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Data rate supported for this port." ::= { smFivePortCfgEntry 16 } switchModSixPortCfg OBJECT IDENTIFIER ::= { switchPortCfg 6 } smSixPortCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF SmSixPortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 6 port configuration information. Note: This option is not supported on all I/O modules." ::= { switchModSixPortCfg 1 } smSixPortCfgEntry OBJECT-TYPE SYNTAX SmSixPortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 6 port configuration information table entry" INDEX { smSixPortCfgIndex } ::= { smSixPortCfgTable 1 } SmSixPortCfgEntry ::= SEQUENCE { smSixPortCfgIndex INTEGER, smSixPortCfgLabel OCTET STRING, smSixPortCfgType INTEGER, smSixPortCfgLinkSetting INTEGER, smSixPortCfgLinkState INTEGER, smSixPortCfgSpeedSetting OCTET STRING, smSixPortCfgSpeedStatus OCTET STRING, smSixPortCfgAvailSpeeds OCTET STRING, smSixPortCfgMedia INTEGER, smSixPortCfgProtocol INTEGER, smSixPortCfgWidth INTEGER, smSixPortCfgCableLength INTEGER, smSixPortCfgCableType OCTET STRING, smSixPortCfgVendorName OCTET STRING, smSixPortCfgCompatibility INTEGER, smSixPortCfgDataRate INTEGER } smSixPortCfgIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 6 port sequence index." ::= { smSixPortCfgEntry 1 } smSixPortCfgLabel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 6 port label" ::= { smSixPortCfgEntry 2 } smSixPortCfgType OBJECT-TYPE SYNTAX INTEGER { unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11) } ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 6 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type." ::= { smSixPortCfgEntry 3 } smSixPortCfgLinkSetting OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Current port link setting for Switch Module 6." ::= { smSixPortCfgEntry 4 } smSixPortCfgLinkState OBJECT-TYPE SYNTAX INTEGER { down(0), up(1), initialized(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Current port link state of Switch Module 6." ::= { smSixPortCfgEntry 5 } smSixPortCfgSpeedSetting OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smSixPortCfgAvailSpeeds are applicable to setting this mib object." ::= { smSixPortCfgEntry 6 } smSixPortCfgSpeedStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Current port speed of Switch Module 6." ::= { smSixPortCfgEntry 7 } smSixPortCfgAvailSpeeds OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Available speed setting per port for Switch Module 6. If there is more than one setting, the speeds are separated by a comma and then a space." ::= { smSixPortCfgEntry 8 } smSixPortCfgMedia OBJECT-TYPE SYNTAX INTEGER { copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port media type of Switch Module 6." ::= { smSixPortCfgEntry 9 } smSixPortCfgProtocol OBJECT-TYPE SYNTAX INTEGER { ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port protocol of Switch Module 6." ::= { smSixPortCfgEntry 10 } smSixPortCfgWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The width of the port in terms of how many combined cables are present for Switch Module 6. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count." ::= { smSixPortCfgEntry 11 } smSixPortCfgCableLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The length (in meters) of the cable supported by this port for Switch Module 6. A value of 0 indicates this field is not applicable to the switch ports." ::= { smSixPortCfgEntry 12 } smSixPortCfgCableType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "External cable type for this port, for example, active copper or passive fiber." ::= { smSixPortCfgEntry 13 } smSixPortCfgVendorName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The cable manufacturer." ::= { smSixPortCfgEntry 14 } smSixPortCfgCompatibility OBJECT-TYPE SYNTAX INTEGER { incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Compatibility of the external cable that is plugged into the port." ::= { smSixPortCfgEntry 15 } smSixPortCfgDataRate OBJECT-TYPE SYNTAX INTEGER { sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Data rate supported for this port." ::= { smSixPortCfgEntry 16 } switchModSevenPortCfg OBJECT IDENTIFIER ::= { switchPortCfg 7 } smSevenPortCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF SmSevenPortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 7 port configuration information. Note: This option is not supported on all I/O modules." ::= { switchModSevenPortCfg 1 } smSevenPortCfgEntry OBJECT-TYPE SYNTAX SmSevenPortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 7 port configuration information table entry" INDEX { smSevenPortCfgIndex } ::= { smSevenPortCfgTable 1 } SmSevenPortCfgEntry ::= SEQUENCE { smSevenPortCfgIndex INTEGER, smSevenPortCfgLabel OCTET STRING, smSevenPortCfgType INTEGER, smSevenPortCfgLinkSetting INTEGER, smSevenPortCfgLinkState INTEGER, smSevenPortCfgSpeedSetting OCTET STRING, smSevenPortCfgSpeedStatus OCTET STRING, smSevenPortCfgAvailSpeeds OCTET STRING, smSevenPortCfgMedia INTEGER, smSevenPortCfgProtocol INTEGER, smSevenPortCfgWidth INTEGER, smSevenPortCfgCableLength INTEGER, smSevenPortCfgCableType OCTET STRING, smSevenPortCfgVendorName OCTET STRING, smSevenPortCfgCompatibility INTEGER, smSevenPortCfgDataRate INTEGER } smSevenPortCfgIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 7 port sequence index." ::= { smSevenPortCfgEntry 1 } smSevenPortCfgLabel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 7 port label" ::= { smSevenPortCfgEntry 2 } smSevenPortCfgType OBJECT-TYPE SYNTAX INTEGER { unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11) } ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 7 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type." ::= { smSevenPortCfgEntry 3 } smSevenPortCfgLinkSetting OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Current port link setting for Switch Module 7." ::= { smSevenPortCfgEntry 4 } smSevenPortCfgLinkState OBJECT-TYPE SYNTAX INTEGER { down(0), up(1), initialized(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Current port link state of Switch Module 7." ::= { smSevenPortCfgEntry 5 } smSevenPortCfgSpeedSetting OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smSevenPortCfgAvailSpeeds are applicable to setting this mib object." ::= { smSevenPortCfgEntry 6 } smSevenPortCfgSpeedStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Current port speed of Switch Module 7." ::= { smSevenPortCfgEntry 7 } smSevenPortCfgAvailSpeeds OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Available speed setting per port for Switch Module 7. If there is more than one setting, the speeds are separated by a comma and then a space." ::= { smSevenPortCfgEntry 8 } smSevenPortCfgMedia OBJECT-TYPE SYNTAX INTEGER { copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port media type of Switch Module 7." ::= { smSevenPortCfgEntry 9 } smSevenPortCfgProtocol OBJECT-TYPE SYNTAX INTEGER { ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port protocol of Switch Module 7." ::= { smSevenPortCfgEntry 10 } smSevenPortCfgWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The width of the port in terms of how many combined cables are present for Switch Module 7. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count." ::= { smSevenPortCfgEntry 11 } smSevenPortCfgCableLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The length (in meters) of the cable supported by this port for Switch Module 7. A value of 0 indicates this field is not applicable to the switch ports." ::= { smSevenPortCfgEntry 12 } smSevenPortCfgCableType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "External cable type for this port, for example, active copper or passive fiber." ::= { smSevenPortCfgEntry 13 } smSevenPortCfgVendorName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The cable manufacturer." ::= { smSevenPortCfgEntry 14 } smSevenPortCfgCompatibility OBJECT-TYPE SYNTAX INTEGER { incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Compatibility of the external cable that is plugged into the port." ::= { smSevenPortCfgEntry 15 } smSevenPortCfgDataRate OBJECT-TYPE SYNTAX INTEGER { sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Data rate supported for this port." ::= { smSevenPortCfgEntry 16 } switchModEightPortCfg OBJECT IDENTIFIER ::= { switchPortCfg 8 } smEightPortCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF SmEightPortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 8 port configuration information. Note: This option is not supported on all I/O modules." ::= { switchModEightPortCfg 1 } smEightPortCfgEntry OBJECT-TYPE SYNTAX SmEightPortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 8 port configuration information table entry" INDEX { smEightPortCfgIndex } ::= { smEightPortCfgTable 1 } SmEightPortCfgEntry ::= SEQUENCE { smEightPortCfgIndex INTEGER, smEightPortCfgLabel OCTET STRING, smEightPortCfgType INTEGER, smEightPortCfgLinkSetting INTEGER, smEightPortCfgLinkState INTEGER, smEightPortCfgSpeedSetting OCTET STRING, smEightPortCfgSpeedStatus OCTET STRING, smEightPortCfgAvailSpeeds OCTET STRING, smEightPortCfgMedia INTEGER, smEightPortCfgProtocol INTEGER, smEightPortCfgWidth INTEGER, smEightPortCfgCableLength INTEGER, smEightPortCfgCableType OCTET STRING, smEightPortCfgVendorName OCTET STRING, smEightPortCfgCompatibility INTEGER, smEightPortCfgDataRate INTEGER } smEightPortCfgIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 8 port sequence index." ::= { smEightPortCfgEntry 1 } smEightPortCfgLabel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 8 port label" ::= { smEightPortCfgEntry 2 } smEightPortCfgType OBJECT-TYPE SYNTAX INTEGER { unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11) } ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 8 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type." ::= { smEightPortCfgEntry 3 } smEightPortCfgLinkSetting OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Current port link setting for Switch Module 8." ::= { smEightPortCfgEntry 4 } smEightPortCfgLinkState OBJECT-TYPE SYNTAX INTEGER { down(0), up(1), initialized(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Current port link state of Switch Module 8." ::= { smEightPortCfgEntry 5 } smEightPortCfgSpeedSetting OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smEightPortCfgAvailSpeeds are applicable to setting this mib object." ::= { smEightPortCfgEntry 6 } smEightPortCfgSpeedStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Current port speed of Switch Module 8." ::= { smEightPortCfgEntry 7 } smEightPortCfgAvailSpeeds OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Available speed setting per port for Switch Module 8. If there is more than one setting, the speeds are separated by a comma and then a space." ::= { smEightPortCfgEntry 8 } smEightPortCfgMedia OBJECT-TYPE SYNTAX INTEGER { copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port media type of Switch Module 8." ::= { smEightPortCfgEntry 9 } smEightPortCfgProtocol OBJECT-TYPE SYNTAX INTEGER { ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port protocol of Switch Module 8." ::= { smEightPortCfgEntry 10 } smEightPortCfgWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The width of the port in terms of how many combined cables are present for Switch Module 8. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count." ::= { smEightPortCfgEntry 11 } smEightPortCfgCableLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The length (in meters) of the cable supported by this port for Switch Module 8. A value of 0 indicates this field is not applicable to the switch ports." ::= { smEightPortCfgEntry 12 } smEightPortCfgCableType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "External cable type for this port, for example, active copper or passive fiber." ::= { smEightPortCfgEntry 13 } smEightPortCfgVendorName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The cable manufacturer." ::= { smEightPortCfgEntry 14 } smEightPortCfgCompatibility OBJECT-TYPE SYNTAX INTEGER { incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Compatibility of the external cable that is plugged into the port." ::= { smEightPortCfgEntry 15 } smEightPortCfgDataRate OBJECT-TYPE SYNTAX INTEGER { sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Data rate supported for this port." ::= { smEightPortCfgEntry 16 } switchModNinePortCfg OBJECT IDENTIFIER ::= { switchPortCfg 9 } smNinePortCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF SmNinePortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 9 port configuration information. Note: This option is not supported on all I/O modules." ::= { switchModNinePortCfg 1 } smNinePortCfgEntry OBJECT-TYPE SYNTAX SmNinePortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 9 port configuration information table entry" INDEX { smNinePortCfgIndex } ::= { smNinePortCfgTable 1 } SmNinePortCfgEntry ::= SEQUENCE { smNinePortCfgIndex INTEGER, smNinePortCfgLabel OCTET STRING, smNinePortCfgType INTEGER, smNinePortCfgLinkSetting INTEGER, smNinePortCfgLinkState INTEGER, smNinePortCfgSpeedSetting OCTET STRING, smNinePortCfgSpeedStatus OCTET STRING, smNinePortCfgAvailSpeeds OCTET STRING, smNinePortCfgMedia INTEGER, smNinePortCfgProtocol INTEGER, smNinePortCfgWidth INTEGER, smNinePortCfgCableLength INTEGER, smNinePortCfgCableType OCTET STRING, smNinePortCfgVendorName OCTET STRING, smNinePortCfgCompatibility INTEGER, smNinePortCfgDataRate INTEGER } smNinePortCfgIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 9 port sequence index." ::= { smNinePortCfgEntry 1 } smNinePortCfgLabel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 9 port label" ::= { smNinePortCfgEntry 2 } smNinePortCfgType OBJECT-TYPE SYNTAX INTEGER { unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11) } ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 9 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type." ::= { smNinePortCfgEntry 3 } smNinePortCfgLinkSetting OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Current port link setting for Switch Module 9." ::= { smNinePortCfgEntry 4 } smNinePortCfgLinkState OBJECT-TYPE SYNTAX INTEGER { down(0), up(1), initialized(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Current port link state of Switch Module 9." ::= { smNinePortCfgEntry 5 } smNinePortCfgSpeedSetting OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smNinePortCfgAvailSpeeds are applicable to setting this mib object." ::= { smNinePortCfgEntry 6 } smNinePortCfgSpeedStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Current port speed of Switch Module 9." ::= { smNinePortCfgEntry 7 } smNinePortCfgAvailSpeeds OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Available speed setting per port for Switch Module 9. If there is more than one setting, the speeds are separated by a comma and then a space." ::= { smNinePortCfgEntry 8 } smNinePortCfgMedia OBJECT-TYPE SYNTAX INTEGER { copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port media type of Switch Module 9." ::= { smNinePortCfgEntry 9 } smNinePortCfgProtocol OBJECT-TYPE SYNTAX INTEGER { ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port protocol of Switch Module 9." ::= { smNinePortCfgEntry 10 } smNinePortCfgWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The width of the port in terms of how many combined cables are present for Switch Module 9. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count." ::= { smNinePortCfgEntry 11 } smNinePortCfgCableLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The length (in meters) of the cable supported by this port for Switch Module 9. A value of 0 indicates this field is not applicable to the switch ports." ::= { smNinePortCfgEntry 12 } smNinePortCfgCableType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "External cable type for this port, for example, active copper or passive fiber." ::= { smNinePortCfgEntry 13 } smNinePortCfgVendorName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The cable manufacturer." ::= { smNinePortCfgEntry 14 } smNinePortCfgCompatibility OBJECT-TYPE SYNTAX INTEGER { incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Compatibility of the external cable that is plugged into the port." ::= { smNinePortCfgEntry 15 } smNinePortCfgDataRate OBJECT-TYPE SYNTAX INTEGER { sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Data rate supported for this port." ::= { smNinePortCfgEntry 16 } switchModTenPortCfg OBJECT IDENTIFIER ::= { switchPortCfg 10 } smTenPortCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF SmTenPortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 10 port configuration information. Note: This option is not supported on all I/O modules." ::= { switchModTenPortCfg 1 } smTenPortCfgEntry OBJECT-TYPE SYNTAX SmTenPortCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module 10 port configuration information table entry" INDEX { smTenPortCfgIndex } ::= { smTenPortCfgTable 1 } SmTenPortCfgEntry ::= SEQUENCE { smTenPortCfgIndex INTEGER, smTenPortCfgLabel OCTET STRING, smTenPortCfgType INTEGER, smTenPortCfgLinkSetting INTEGER, smTenPortCfgLinkState INTEGER, smTenPortCfgSpeedSetting OCTET STRING, smTenPortCfgSpeedStatus OCTET STRING, smTenPortCfgAvailSpeeds OCTET STRING, smTenPortCfgMedia INTEGER, smTenPortCfgProtocol INTEGER, smTenPortCfgWidth INTEGER, smTenPortCfgCableLength INTEGER, smTenPortCfgCableType OCTET STRING, smTenPortCfgVendorName OCTET STRING, smTenPortCfgCompatibility INTEGER, smTenPortCfgDataRate INTEGER } smTenPortCfgIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 10 port sequence index." ::= { smTenPortCfgEntry 1 } smTenPortCfgLabel OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 10 port label" ::= { smTenPortCfgEntry 2 } smTenPortCfgType OBJECT-TYPE SYNTAX INTEGER { unused(0), externalPort(1), externalManagementPort(2), externalDualPort(3), bladePort(4), mmManagementPort(5), uplinkPort(6), interModulePort(7), interModuleManagementPort(8), interModuleDualPort(9), interModuleExternalBridgePort(10), interModuleDualInternalBridgePort(11) } ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module 10 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for external management connection. This port is not used for data traffic from remote to blades. External dual port: This external port is used for both data traffic to blades as well as for management. Blade port: This port is connected to the blade. Management Module Management port: This port is connected to the Management Module. Uplink port: This port is configured for up link functionality. Inter-Module port: This port is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Management port: This port is connected to another I/O Module for management purpose. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type. Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data and management purposes. The port type is either by design connected to another I/O Module, by user configured, or by AMM setting the port type." ::= { smTenPortCfgEntry 3 } smTenPortCfgLinkSetting OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Current port link setting for Switch Module 10." ::= { smTenPortCfgEntry 4 } smTenPortCfgLinkState OBJECT-TYPE SYNTAX INTEGER { down(0), up(1), initialized(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Current port link state of Switch Module 10." ::= { smTenPortCfgEntry 5 } smTenPortCfgSpeedSetting OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of the physical port can be tuned automatically. NOTE: Only the speeds from smTenPortCfgAvailSpeeds are applicable to setting this mib object." ::= { smTenPortCfgEntry 6 } smTenPortCfgSpeedStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Current port speed of Switch Module 10." ::= { smTenPortCfgEntry 7 } smTenPortCfgAvailSpeeds OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Available speed setting per port for Switch Module 10. If there is more than one setting, the speeds are separated by a comma and then a space." ::= { smTenPortCfgEntry 8 } smTenPortCfgMedia OBJECT-TYPE SYNTAX INTEGER { copper(0), serdes(1), opticalShortHaul(32), opticalLongHaul(48), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port media type of Switch Module 10." ::= { smTenPortCfgEntry 9 } smTenPortCfgProtocol OBJECT-TYPE SYNTAX INTEGER { ethernet(16), fibreChannel(32), scalability(48), infiniband(64), pciExpress(80), myrinet(112), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Port protocol of Switch Module 10." ::= { smTenPortCfgEntry 10 } smTenPortCfgWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The width of the port in terms of how many combined cables are present for Switch Module 10. A value of 0 indicates this field is not applicable to the switch ports. This data is also known as the lane count." ::= { smTenPortCfgEntry 11 } smTenPortCfgCableLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The length (in meters) of the cable supported by this port for Switch Module 10. A value of 0 indicates this field is not applicable to the switch ports." ::= { smTenPortCfgEntry 12 } smTenPortCfgCableType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "External cable type for this port, for example, active copper or passive fiber." ::= { smTenPortCfgEntry 13 } smTenPortCfgVendorName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The cable manufacturer." ::= { smTenPortCfgEntry 14 } smTenPortCfgCompatibility OBJECT-TYPE SYNTAX INTEGER { incompatible(0), compatible(1), compatibleNotRecommended(2), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Compatibility of the external cable that is plugged into the port." ::= { smTenPortCfgEntry 15 } smTenPortCfgDataRate OBJECT-TYPE SYNTAX INTEGER { sdr(0), ddr(1), qdr(2), edr(3), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Data rate supported for this port." ::= { smTenPortCfgEntry 16 } -- ******************************************************************************** -- RAID Controller config -- ******************************************************************************** raidControllerConfig OBJECT IDENTIFIER ::= { switchModule 3 } raidControllerTable OBJECT-TYPE SYNTAX SEQUENCE OF RaidControllerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "RAID Controller control table." ::= { raidControllerConfig 1 } raidControllerEntry OBJECT-TYPE SYNTAX RaidControllerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "RAID Controller control table entry." INDEX { raidControllerIndex } ::= { raidControllerTable 1 } RaidControllerEntry ::= SEQUENCE { raidControllerIndex INTEGER, raidControllerId INTEGER, raidControllerExists INTEGER, raidControllerPowerState INTEGER, raidControllerMACAddress OCTET STRING, raidControllerSasID OCTET STRING, raidControllerPingRequest INTEGER } raidControllerIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "RAID Controller control table index. This MIB object is for SAS Controller Modules only." ::= { raidControllerEntry 1 } raidControllerId OBJECT-TYPE SYNTAX INTEGER { module3(3), module4(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The I/O Module numeric identifier for the SAS Controller Module. This MIB object is for SAS Controller Modules only." ::= { raidControllerEntry 2 } raidControllerExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the I/O Module specified for the RAID Controller exists or not. This MIB object is for SAS Controller Modules only." ::= { raidControllerEntry 3 } raidControllerPowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), shutdownInProgress(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the I/O Module is powered on or not. This MIB object is for SAS Controller Modules only." ::= { raidControllerEntry 4 } raidControllerMACAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address for the RAID Controller network interface. This MIB object is for SAS Controller Modules only." ::= { raidControllerEntry 5 } raidControllerSasID OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The hardware VPD SAS ID for the RAID Controller network interface. This MIB object is for SAS Controller Modules only." ::= { raidControllerEntry 6 } raidControllerPingRequest OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Sends a ping to the current IP address of the RAID Controller network interface. This MIB object can not be set, if AMM grants I/O Module the Protected Mode permission and the module goes into Protected Mode. NOTE: Value returned for the GET command is meaningless for this MIB object This MIB object is for SAS Controller Modules only." ::= { raidControllerEntry 7 } raidControllerNetworkCfg OBJECT IDENTIFIER ::= { raidControllerConfig 2 } rcCurrentIPInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCurrentIPInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "RAID Controller current IP table. This MIB object is for SAS Controller Modules only." ::= { raidControllerNetworkCfg 1 } rcCurrentIPInfoEntry OBJECT-TYPE SYNTAX RcCurrentIPInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "RAID Controller current IP table entry. This MIB object is for SAS Controller Modules only." INDEX { rcCurrentIPInfoIndex } ::= { rcCurrentIPInfoTable 1 } RcCurrentIPInfoEntry ::= SEQUENCE { rcCurrentIPInfoIndex INTEGER, rcCurrentIPInfoId INTEGER, rcCurrentIPInfoExists INTEGER, rcCurrentIPInfoPowerState INTEGER, rcCurrentIPAddr IpAddress, rcCurrentSubnetMask IpAddress, rcCurrentGateway IpAddress, rcCurrentIPConfigMethod INTEGER, rcCurrentRaidedVlanId INTEGER } rcCurrentIPInfoIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "RAID Controller current IP table index. This MIB object is for SAS Controller Modules only." ::= { rcCurrentIPInfoEntry 1 } rcCurrentIPInfoId OBJECT-TYPE SYNTAX INTEGER { module3(3), module4(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The I/O Module numeric identifier for the RAID Controller. This MIB object is for SAS Controller Modules only." ::= { rcCurrentIPInfoEntry 2 } rcCurrentIPInfoExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the I/O Module exists or not. This MIB object is for SAS Controller Modules only." ::= { rcCurrentIPInfoEntry 3 } rcCurrentIPInfoPowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), shutdownInProgress(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the I/O Module is powered on or not. This MIB object is for SAS Controller Modules only." ::= { rcCurrentIPInfoEntry 4 } rcCurrentIPAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The current IP address for the RAID Controller network interface. This MIB object is for SAS Controller Modules only." ::= { rcCurrentIPInfoEntry 5 } rcCurrentSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The current subnet mask for the RAID Controller network interface. This MIB object is for SAS Controller Modules only." ::= { rcCurrentIPInfoEntry 6 } rcCurrentGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The current subnet mask for the RAID Controller network interface. This MIB object is for SAS Controller Modules only." ::= { rcCurrentIPInfoEntry 7 } rcCurrentIPConfigMethod OBJECT-TYPE SYNTAX INTEGER { unknown(0), static(1), dhcp(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current IP gateway for the RAID Controller network interface. This MIB object is for SAS Controller Modules only." ::= { rcCurrentIPInfoEntry 8 } rcCurrentRaidedVlanId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current virtual LAN ID for the RAID Controller network interface. This MIB object is for SAS Controller Modules only." ::= { rcCurrentIPInfoEntry 9 } rcNewIPInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF RcNewIPInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "RAID Controller new IP configuration table. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode." ::= { raidControllerNetworkCfg 2 } rcNewIPInfoEntry OBJECT-TYPE SYNTAX RcNewIPInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "RAID Controller new IP configuration information table entry. This MIB object is for SAS Controller Modules only. NOTE: This MIB table is not applicable to modules that are running in Network Address Translation (NAT) Mode." INDEX { rcNewIPInfoIndex } ::= { rcNewIPInfoTable 1 } RcNewIPInfoEntry ::= SEQUENCE { rcNewIPInfoIndex INTEGER, rcNewIPInfoId INTEGER, rcNewIPInfoExists INTEGER, rcNewIPInfoPowerState INTEGER, rcNewIPAddr IpAddress, rcNewSubnetMask IpAddress, rcNewGateway IpAddress, rcNewIPConfigMethod INTEGER, rcNewIPConfigEnableDisable INTEGER } rcNewIPInfoIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "RAID Controller new IP configuration information index. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode." ::= { rcNewIPInfoEntry 1 } rcNewIPInfoId OBJECT-TYPE SYNTAX INTEGER { module3(3), module4(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The I/O Module numeric identifier for the RAID Controller. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode." ::= { rcNewIPInfoEntry 2 } rcNewIPInfoExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the I/O Module exists or not. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode." ::= { rcNewIPInfoEntry 3 } rcNewIPInfoPowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), shutdownInProgress(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the I/O Module is powered on or not. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode." ::= { rcNewIPInfoEntry 4 } rcNewIPAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The new IP address for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a new value, rcNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode." ::= { rcNewIPInfoEntry 5 } rcNewSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The new subnet mask for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a new value, rcNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode." ::= { rcNewIPInfoEntry 6 } rcNewGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The new IP gateway for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a new value, rcNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode." ::= { rcNewIPInfoEntry 7 } rcNewIPConfigMethod OBJECT-TYPE SYNTAX INTEGER { unknown(0), static(1), dhcp(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The new IP configuration method for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a new value, rcNewIpconfigEnableDisable object must first be set to disabled. NOTE: The value 'DHCP' can not be used to set. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode." ::= { rcNewIPInfoEntry 8 } rcNewIPConfigEnableDisable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "A set command enables new IP configurations that have been defined. A get command indicates whether new IP configurations that have been enabled. NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode permission and the module goes into Protected Mode. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode." ::= { rcNewIPInfoEntry 11 } chassisTopology OBJECT IDENTIFIER ::= { blades 4 } chassisResponseVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Chassis response version." ::= { chassisTopology 1 } chassisFlags OBJECT-TYPE SYNTAX INTEGER { serverBlade(1), rackOrStandAlone(0) } ACCESS read-only STATUS mandatory DESCRIPTION "Chassis flags. 1 = a server blade chassis, 0 = a rack or standalone chassis." ::= { chassisTopology 2 } chassisName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the active MM as a null terminated string." ::= { chassisTopology 3 } chassisNoOfFPsSupported OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of fan packs (FPs) supported. NOTE: Fan packs are also referred to as Power Module Cooling Devices." ::= { chassisTopology 18 } chassisNoOfPBsSupported OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of processor blades (PBs) supported." ::= { chassisTopology 19 } chassisNoOfSMsSupported OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of switch modules (SMs) supported." ::= { chassisTopology 20 } chassisNoOfMMsSupported OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of management modules (MMs) supported." ::= { chassisTopology 21 } chassisNoOfPMsSupported OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of power modules (PMs) supported." ::= { chassisTopology 22 } chassisNoOfMTsSupported OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of media trays (MTs) supported." ::= { chassisTopology 23 } chassisNoOfBlowersSupported OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of blowers supported. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { chassisTopology 24 } chassisPBsInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blades that are installed on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blades supported. If a blade is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if blades are installed in bays 1, 5, and 13, and 14 blades are supported, the string would look like '10001000000010'." ::= { chassisTopology 25 } chassisSMsInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The switch modules that are installed on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of switch modules supported. If a switch module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if switch modules are installed in bays 1 and 3, and 4 switch modules are supported, the string would look like '1011' for BladeCenter and BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT." ::= { chassisTopology 29 } chassisMMsInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The management modules that are installed on the chassis. The management modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of management modules supported. If a management module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a management module is installed in bay 1, and 2 management modules are supported, the string would look like '10'." ::= { chassisTopology 30 } chassisPMsInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The power modules that are installed on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of power modules supported. If a power module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if power modules are installed in bays 1 and 3, and 4 power modules are supported, the string would look like '1010'." ::= { chassisTopology 31 } chassisMTInstalled OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether at least one media tray (MT) is installed." ::= { chassisTopology 32 } chassisBlowersInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The blowers that are installed on the chassis. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of blowers supported. If a blower is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a blower is installed in bay 1, and 2 blowers are supported, the string would look like '10'. NOTE: Blowers are also referred to as Chassis Cooling Devices." ::= { chassisTopology 33 } chassisActiveMM OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The active management module (MM)." ::= { chassisTopology 34 } chassisKVMOwner OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The blade that currently owns the keyboard/video/monitor (KVM). 0 = the KVM devices are owned by the management module." ::= { chassisTopology 35 } chassisMediaTrayOwner OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The blade that currently owns the media tray. 0 = the media tray is owned by the management module." ::= { chassisTopology 36 } chassisFPsInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The fan packs that are installed on the chassis. The fan packs are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of fan packs supported. If a fan pack is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if fan packs are installed in bays 1 and 3, and 4 fan packs are supported, the string would look like '1010'. NOTE: Fan packs are also referred to as Power Module Cooling Devices." ::= { chassisTopology 37 } chassisType OBJECT-TYPE SYNTAX INTEGER { bladeCenterOrBladeCenterH(97), bladeCenterTOrBladeCenterHT(98) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of the chassis. The BladeCenterS chassis and BladeCenterE are part of the bladeCenterOrBladeCenterH type. This MIB object should be used in conjunction with chassisSubType MIB object to determine the characteristic of the chassis." ::= { chassisTopology 38 } chassisSubtype OBJECT-TYPE SYNTAX INTEGER { bladeCenterOrBladeCenterT(0), bladeCenterHOrBladeCenterHT(2), bladeCenterS(3), bladeCenterE(4), bladeCenterH(5), bladeCenterT(32), unknown(255) } ACCESS read-only STATUS mandatory DESCRIPTION "The subtype of the chassis. This MIB object should be used in conjunction with chassisType MIB object to determine the characteristic of the chassis." ::= { chassisTopology 39 } -- ******************************************************************************** chassisNoOfFBsSupported OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of Front Bezel (FBs) supported." ::= { chassisTopology 40 } chassisNoOfAPsSupported OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of Alarm Panel (APs) supported." ::= { chassisTopology 41 } chassisNoOfNCsSupported OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Number of Network Clocks (NCs) supported." ::= { chassisTopology 42 } chassisNoOfMXsSupported OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of Multiplexer Expansion modules (MXs) supported." ::= { chassisTopology 43 } chassisNoOfMMIsSupported OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of management module interposers (MMIs) supported." ::= { chassisTopology 44 } chassisNoOfSMIsSupported OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of switch module interposers (SMIs) supported." ::= { chassisTopology 45 } chassisNoOfFBsInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The return value of '1'indicates the front bezel is installed on the chassis. The value of '0' indicates the front bezel is not installed." ::= { chassisTopology 46 } chassisNoOfAPsInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The return value of '1'indicates the alarm panel is installed on the chassis. The value of '0' indicates the alarm panel is not installed." ::= { chassisTopology 47 } chassisNoOfNCsInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS deprecated DESCRIPTION "The network clock cards that are installed on the chassis. The network clock cards are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of network clock cards supported. If a network clock card is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if a network clock card is installed in bays 1, and 2 network clock cards are supported, the string would look like '10'." ::= { chassisTopology 48 } chassisNoOfMXsInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The Multiplexer Expansion Modules that are installed on the chassis. The Multiplexer Expansion Modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of Multiplexer Expansion Modules supported. If a Multiplexer Expansion Module is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if Multiplexer Expansion Module is installed in bays 1, and 2 Multiplexer Expansion Modules are supported, the string would look like '10'." ::= { chassisTopology 49 } chassisNoOfMMIsInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The flex cables that are installed on the chassis. The flex cables are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of flex cables supported. If a flex cable is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if flex cable is installed in bays 1, and 2 flex cables are supported, the string would look like '10'." ::= { chassisTopology 50 } chassisNoOfSMIsInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The interposers that are installed on the chassis. The interposers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of interposers supported. If an interposer is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if interposer is installed in bays 1, and 10 interposers are supported, the string would look like '1000000000'." ::= { chassisTopology 51 } chassisNoOfMTsInstalled OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The media trays that are installed on the chassis. The media trays are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the number of media trays supported. If a media tray is installed in a bay, a 1 is present in the string in the position representing the bay ID as read from left to right. For example, if media trays are installed in bays 1, and 2 media trays are, the string would look like '10'." ::= { chassisTopology 52 } -- ******************************************************************************** managementModule OBJECT IDENTIFIER ::= { blades 5 } -- ******************************************************************************** mmStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MmStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of the management module status. For consistent results, view as a table and not as individual entries." ::= { managementModule 1 } mmStatusEntry OBJECT-TYPE SYNTAX MmStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Management module status entry. For consistent results, view as a table and not as individual entries." INDEX { mmStatusIndex } ::= { mmStatusTable 1 } MmStatusEntry ::= SEQUENCE { mmStatusIndex INTEGER, mmPresent INTEGER, mmExtIpAddress IpAddress, mmPrimary INTEGER, mmHealthState INTEGER } mmStatusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Management module status index." ::= { mmStatusEntry 1 } mmPresent OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Management module current status." ::= { mmStatusEntry 2 } mmExtIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Management module external IP address. NOTE: The IPv6 addresses assigned to the AMM may be viewed with the extEthernetInterfaceIPv6 objects" ::= { mmStatusEntry 3 } mmPrimary OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if this Management module is a primary or not. NOTE: If there is no standby MM, this value defaults to primary." ::= { mmStatusEntry 4 } mmHealthState OBJECT-TYPE SYNTAX INTEGER { unknown(0), good(1), warning(2), bad(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The health state for the management module. 0 = unknown, 1 = good, 2 = warning, 3 = bad." ::= { mmStatusEntry 5 } -- ******************************************************************************** -- Storage Task for configuration -- ******************************************************************************** storage OBJECT IDENTIFIER ::= { blades 6 } storageStatus OBJECT IDENTIFIER ::= { storage 1 } storageStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF StorageStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of the storage module status. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only." ::= { storageStatus 1 } storageStatusEntry OBJECT-TYPE SYNTAX StorageStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Storage Module Status Table Entry." INDEX { storageStatusIndex } ::= { storageStatusTable 1 } StorageStatusEntry ::= SEQUENCE { storageStatusIndex INTEGER, storageBayNumber OCTET STRING, storageState INTEGER, storageName OCTET STRING } storageStatusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Storage device status table index." ::= { storageStatusEntry 1 } storageBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Bay number of the Storage device." ::= { storageStatusEntry 2 } storageState OBJECT-TYPE SYNTAX INTEGER { unknown(0), good(1), warning(2), critical(3), notAvailable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Storage device state." ::= { storageStatusEntry 3 } storageName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the storage device." ::= { storageStatusEntry 4 } storageConfiguration OBJECT IDENTIFIER ::= { storage 2 } storageSwitchConfiguration OBJECT IDENTIFIER ::= { storageConfiguration 1 } -- ******************************************************************************** -- Shows details about all possible zone configurations available on all SAS switches -- and allows a user to select one and make it the active zone configuration -- ******************************************************************************** storageSwitchZoneCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF StorageSwitchZoneCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all the zone configurations stored on switch modules. For consistent results, view as a table and not as individual entries. Before activating a new zone configuration via the switchActiveZoneCfg object, a user must consider the following: 1) Changing the zone configuration may cause disruption in the storage access of blades connected to this SAS Module. It is highly recommended that you first ensure that the blades have completed all storage accesses. You may want to shutdown the blade OS prior to changing your zone configuration. 2) When selecting a zone configuration, ensure that it is appropriate for the number of SAS switches installed in your chassis. This can be determined from the switchZoneCfgDescription text. 3) When selecting a zone configuration, ensure that it exists first on all SAS switches. This can be determined by querying the storageSwitchZoneCfgTable. In addition, for user-defined zone configurations, even if the number is the same, ensure that the actual zone configurations are identical or compatible. You will need to use an application, such as the Switch Configuration Manager (SCM) to verify this. 4) All SAS switches must be in operational state prior to activating a new zone configuration. This can be determined by querying the activeZoneCfgNumberBySwitch object and ensuring that none of the 2xx codes are returned." ::= { storageSwitchConfiguration 1 } storageSwitchZoneCfgEntry OBJECT-TYPE SYNTAX StorageSwitchZoneCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module Zone Configuration Management Entry." INDEX { switchZoneCfgIndex } ::= { storageSwitchZoneCfgTable 1 } StorageSwitchZoneCfgEntry ::= SEQUENCE { switchZoneCfgIndex INTEGER, switchZoneCfgBayNumber INTEGER, switchZoneCfgNumber INTEGER, switchZoneCfgStatus INTEGER, switchZoneCfgType INTEGER, switchZoneCfgName OCTET STRING, switchZoneCfgDescription OCTET STRING, switchZoneCfgDate OCTET STRING, switchActiveZoneCfg INTEGER } switchZoneCfgIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch module zone configuration table index." ::= { storageSwitchZoneCfgEntry 1 } switchZoneCfgBayNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The numeric switch bay number." ::= { storageSwitchZoneCfgEntry 2 } switchZoneCfgNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The zone configuration number, also referred to as the configuration store number." ::= { storageSwitchZoneCfgEntry 3 } switchZoneCfgStatus OBJECT-TYPE SYNTAX INTEGER { nonActive(0), active(1), pending(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the zone configuration. Only one configuration is 'Active', others are in 'nonActive' status. When a zone configuration is active on a switch, the status may temporarily indicate pending(2) as it transitions from nonActive(0) to active (1)." ::= { storageSwitchZoneCfgEntry 4 } switchZoneCfgType OBJECT-TYPE SYNTAX INTEGER { userdefined(1), predefined(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of the zone configuration. Predefined are read-only static configurations, and userdefined are read-write configurations that can be created and modified using the Switch Configuration Manager application." ::= { storageSwitchZoneCfgEntry 5 } switchZoneCfgName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A short descriptive name for the zone configuration." ::= { storageSwitchZoneCfgEntry 6 } switchZoneCfgDescription OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A detailed description for the zone configuration." ::= { storageSwitchZoneCfgEntry 7 } switchZoneCfgDate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The date the zone configuration was created." ::= { storageSwitchZoneCfgEntry 8 } switchActiveZoneCfg OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "An object used to activate a particular zone configuration. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { storageSwitchZoneCfgEntry 9 } -- ******************************************************************************** -- Shows which zone configuration is currently the active one on each SAS switch. -- ******************************************************************************** storageSwitchActiveZoneCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF StorageSwitchActiveZoneCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table showing the zone configuration that is currently active on a given switch module. For consistent results, view as a table and not as individual entries." ::= { storageSwitchConfiguration 2 } storageSwitchActiveZoneCfgEntry OBJECT-TYPE SYNTAX StorageSwitchActiveZoneCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Active zone configurations Entry." INDEX { activeZoneCfgIndex } ::= { storageSwitchActiveZoneCfgTable 1 } StorageSwitchActiveZoneCfgEntry ::= SEQUENCE { activeZoneCfgIndex INTEGER, activeZoneCfgBayNumber OCTET STRING, activeZoneCfgNumberBySwitch INTEGER, activeZoneCfgNumberByMM INTEGER } activeZoneCfgIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Active zone configurations table index." ::= { storageSwitchActiveZoneCfgEntry 1 } activeZoneCfgBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Bay number of the switch module where active zone configurations exist." ::= { storageSwitchActiveZoneCfgEntry 2 } activeZoneCfgNumberBySwitch OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The zone configuration number active on this SAS switch module as reported by the switch module. If this number differs from the value of the activeZoneCfgNumberByMM object for the same switch, this may indicate a configuration problem. The zone configuration number is also referred to as the zone configuration store. NOTE: 0 = No zone configuration is active on this I/O Module. 253 = I/O module is discovering zone information. 254 = I/O Module is not powered on or in a fault state. 255 = notApplicable." ::= { storageSwitchActiveZoneCfgEntry 3 } activeZoneCfgNumberByMM OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The zone configuration number active on this SAS switch module as known by the management module. If this number differs from the value of the activeZoneCfgNumberBySwitch object for the same switch, this may indicate a configuration problem. The zone configuration number is also referred to as the zone configuration store. NOTE: 0 = No zone configuration is active on this I/O Module. 255 = notApplicable." ::= { storageSwitchActiveZoneCfgEntry 4 } -- ******************************************************************************** -- A quick means of activating the same zone configuration on all SAS switches. -- ******************************************************************************** switchZoneCfgActivation OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object provides a quick means of activating a valid zone configuration on all active SAS switches. The zone configuration to be activated is specified as the value of the SET and can be obtained from the switchZoneCfgNumber object. The zone configuration number is also referred to as the zone configuration store. Before activating a new zone configuration, a user must consider the following: 1) Changing the zone configuration may cause disruption in the storage access of blades connected to this SAS Module. It is highly recommended that you first ensure that the blades have completed all storage accesses. You may want to shutdown the blade OS prior to changing your zone configuration. 2) When selecting a zone configuration, ensure that it is appropriate for the number of SAS switches installed in your chassis. This can be determined from the switchZoneCfgDescription text. 3) When selecting a zone configuration, ensure that it exists first on all SAS switches. This can be determined by querying the storageSwitchZoneCfgTable. In addition, for user-defined zone configurations, even if the number is the same, ensure that the actual zone configurations are identical or compatible. You will need to use an application, such as the Switch Configuration Manager (SCM) to verify this. 4) All SAS switches must be in operational state prior to activating a new zone configuration. This can be determined by querying the activeZoneCfgNumberBySwitch object and ensuring that none of the 2xx codes are returned. NOTE: Value returned for the GET command is meaningless for this MIB object. If any of the switches are not activated, an error response will be returned." ::= { storageSwitchConfiguration 3 } -- ******************************************************************************** -- Firmware Image Information - currently for Iswitches that support multiple images -- ******************************************************************************** firmwareInformation OBJECT IDENTIFIER ::= { blades 8 } smFirmwareInformation OBJECT IDENTIFIER ::= { firmwareInformation 1 } smFirmwareInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF SmFirmwareInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module firmware image information. This table is only applicable to modules that support multiple images" ::= { smFirmwareInformation 1 } smFirmwareInfoEntry OBJECT-TYPE SYNTAX SmFirmwareInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Module firmware image information table entry" INDEX { smFirmwareInfoIndex } ::= { smFirmwareInfoTable 1 } SmFirmwareInfoEntry ::= SEQUENCE { smFirmwareInfoIndex INTEGER, smFirmwareInfoModIndex INTEGER, smFirmwareInfoImageIndex INTEGER, smFirmwareInfoImageName OCTET STRING } smFirmwareInfoIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Sequence index in the firmware table." ::= { smFirmwareInfoEntry 1 } smFirmwareInfoModIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module number." ::= { smFirmwareInfoEntry 2 } smFirmwareInfoImageIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Switch Module firmware image index." ::= { smFirmwareInfoEntry 3 } smFirmwareInfoImageName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Switch Module firmware image name" ::= { smFirmwareInfoEntry 4 } -- ******************************************************************************** -- Firmware update for MM, Switch modules, and blades -- ******************************************************************************** firmwareUpdate OBJECT IDENTIFIER ::= { blades 9 } firmwareUpdateTarget OBJECT-TYPE SYNTAX INTEGER { managementModule(0), switchModule1(11), switchModule2(12), switchModule3(13), switchModule4(14), switchModule5(15), switchModule6(16), switchModule7(17), switchModule8(18), switchModule9(19), switchModule10(20), blade1(31), blade2(32), blade3(33), blade4(34), blade5(35), blade6(36), blade7(37), blade8(38), blade9(39), blade10(40), blade11(41), blade12(42), blade13(43), blade14(44), unknown(255) } ACCESS read-write STATUS mandatory DESCRIPTION "Target module whose firmware will be updated. NOTE: Some switch modules do not allow firmware update. When firmware update is attempted on those switch modules, the agent will report an error." ::= { firmwareUpdate 1 } firmwareUpdateTftpServer OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "If flashing via the legacy method using a tftp server, then set the IP address or host name of the TFTP server where the firmware file resides. The address must be entered in a dotted decimal IP string (e.g. 9.37.44.2). NOTE: IPv6 numeric addresses must be enclosed with brackets (e.g. [fe80::5652:ff:fe50:53b6])." ::= { firmwareUpdate 2 } firmwareUpdateFileName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..254)) ACCESS read-write STATUS mandatory DESCRIPTION "File name of the firmware file." ::= { firmwareUpdate 3 } firmwareUpdateStart OBJECT-TYPE SYNTAX INTEGER { execute(1), execute-with-reboot(2), execute-nowait(3), execute-with-reboot-nowait(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Start updating the firmware of the specified target module. Using execute or execute-with-reboot will cause the SNMP client to wait for the firmware update to complete. Using execute-nowait or execute-with-reboot-nowait will not cause the SNMP client to wait for the update to complete. Instead it will flash the firmware in the background. Note 1: If the execute-with-reboot or execute-with-reboot-nowait option is selected, the target will reset after a successful flash. This option is only valid if the firmwareUpdateTarget object is set to managementModule. Note 2: If flashing from a remote file, then both firmwareUpdateServer and firmwareUpdateFileName must be set. Otherwise if flashing via the legacy method using a tftp server, then both firmwareUpdateTftpServer and firmwareUpdateFileName must be set. Note 3: Depending on the target, it might take up to several minutes for the flash update to complete. Do not reset the target until the control has been returned. At this point, the results will be displayed. Note 4: Use firmwareUpdateStatus to confirm the status of the last firmware update initiated by SNMP method. The Management Module must be restarted for the new firmware to take affect. Note 5: If data encryption is currently enabled on this MM, and you update the MM firmware to a level which does not support data encryption, you will lose all your configuration settings as a result. Note 6: Since some I/O Module types use the AMM TFTP server for firmware file transfer during the firmware update process, the tftpEnable MIB object must be set to enable prior to updating the firmware for these modules. Note 7: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this AMM, when you update the firmware to a level which does not support IPv6, all IPv6 connectivity will be lost, and services/interfaces for which an IPv6 address was configured may not function properly. You will be required to reconfigure these services/interfaces. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { firmwareUpdate 4 } firmwareUpdateStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Get the status of the last firmware update which was initiated through SNMP method." ::= { firmwareUpdate 5 } standbyFirmwareUpdateStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Get the current status of the firmware update for the standby AMM. NOTE: This only applies to systems with a standby AMM." ::= { firmwareUpdate 6 } firmwareImageNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the module can upload more than one image, an image number must be specified after setting the firmware target. Please refer to the firmwareInformation section." ::= { firmwareUpdate 7 } firmwareActiveImage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the module can upload more than one image, an active image number must be specified. Please refer to the firmwareInformation section. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { firmwareUpdate 8 } firmwareUpdateServer OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..254)) ACCESS read-write STATUS mandatory DESCRIPTION "Contains the fully qualified remote location of the firmware packet file. Use firmwareUpdateFileName to specify the filename. A fully qualified remote location contains a supported protocol followed by a colon and two slashes (//), userid and password separated by a colon for login authentication, an @ sign, followed by the hostname or IP address of the server where the packet file resides, followed by an optional port number to the hostname, and the full pathname to the file. Note that if the port number is specified, it must be separated with the hostname (or IP address) by a colon. The AMM currently supports the following protocols: TFTP, FTP, FTPS, HTTP and HTTPS. The complete format of a fully qualified remote location is: ://@/ An example of a fully qualified remote location can be: ftp://USERID:PASSW0RD@192.168.0.2:30045/tmp where the ftp protocol will be used for transferring the file in this location, username is USERID, password is PASSW0RD, host IP address is 192.168.0.2, port number is 30045, and the full pathname for the packet file is /tmp. and firmwareUpdateFileName is set to: CNETCMUS.pkt Some protocols do not need the username, password, and the port number, so the minimum requirement for a fully qualified location can be: :///." ::= { firmwareUpdate 9 } -- ******************************************************************************** -- mm Discovery -- ******************************************************************************** remoteChassis OBJECT IDENTIFIER ::= { blades 10 } remoteChassisTable OBJECT-TYPE SYNTAX SEQUENCE OF RemoteChassisEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of remote chassis information." ::= { remoteChassis 1 } remoteChassisEntry OBJECT-TYPE SYNTAX RemoteChassisEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Remote chassis entry" INDEX { remoteChassisIndex } ::= { remoteChassisTable 1 } RemoteChassisEntry ::= SEQUENCE { remoteChassisIndex INTEGER, systemName OCTET STRING, systemStatus INTEGER, mmType OCTET STRING, mmSerial OCTET STRING, mmFru OCTET STRING, mmIp OCTET STRING, chassisSerial OCTET STRING, chassisFru OCTET STRING, chassisMachineTypeMode OCTET STRING, chassisUuid OCTET STRING, firmwareVersion OCTET STRING, ipStatus INTEGER, ipv6Addresses OCTET STRING } remoteChassisIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Remote chassis discovery sequence index." ::= { remoteChassisEntry 1 } systemName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "System name for this discovery management module." ::= { remoteChassisEntry 2 } systemStatus OBJECT-TYPE SYNTAX INTEGER { critical(0), non-Critical(2), system-Level(4), unknown(9), noResponse(170), normal(255) } ACCESS read-only STATUS mandatory DESCRIPTION "System status summary (chassis)." ::= { remoteChassisEntry 3 } mmType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Service processor type." ::= { remoteChassisEntry 4 } mmSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module serial number." ::= { remoteChassisEntry 5 } mmFru OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Management module Field-Replaceable number." ::= { remoteChassisEntry 6 } mmIp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The IPv4 compliant address of the management module." ::= { remoteChassisEntry 7} chassisSerial OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Chassis serial number." ::= { remoteChassisEntry 8 } chassisFru OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Chassis Field-Replaceable number." ::= { remoteChassisEntry 9 } chassisMachineTypeMode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Chassis machine type and model number." ::= { remoteChassisEntry 10 } chassisUuid OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Chassis unique identifier." ::= { remoteChassisEntry 11 } firmwareVersion OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Firmware version of the discovery management module." ::= { remoteChassisEntry 12 } ipStatus OBJECT-TYPE SYNTAX INTEGER { ipv4(1), ipv6(2), both(3) } ACCESS read-only STATUS mandatory DESCRIPTION "A flag to state if IPv4 and IPv6 are enabled" ::= { remoteChassisEntry 13 } ipv6Addresses OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The IPv6 addresses configured for the chassis." ::= { remoteChassisEntry 14 } chassisDiscovery OBJECT-TYPE SYNTAX INTEGER{ execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Discovery of remote Chassis. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { remoteChassis 2} -- ******************************************************************************** -- Local file management -- ******************************************************************************** fileManagement OBJECT IDENTIFIER ::= { blades 11 } fileTopology OBJECT IDENTIFIER ::= { fileManagement 1 } currentDirectory OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the directory name for listing the requested files." ::= { fileTopology 1 } fileDetailsTable OBJECT-TYPE SYNTAX SEQUENCE OF FileDetailsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of all the files in the specified directory. For consistent results, view as a table and not as individual entries." ::= { fileTopology 2 } fileDetailsEntry OBJECT-TYPE SYNTAX FileDetailsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "File details entry. For consistent results, view as a table and not as individual entries." INDEX { fileIndex } ::= { fileDetailsTable 1 } FileDetailsEntry ::= SEQUENCE { fileIndex INTEGER, fileName OCTET STRING, fileLastUpdate OCTET STRING, fileSize OCTET STRING } fileIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "File sequence index." ::= { fileDetailsEntry 1 } fileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "File name." ::= { fileDetailsEntry 2 } fileLastUpdate OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Date of the latest file update." ::= { fileDetailsEntry 3 } fileSize OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "File size in bytes." ::= { fileDetailsEntry 4 } fileManagementCmd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This field will execute the selected operations on the files. The following operation is supported: DEL name - delete a file Examples: - to delete the file named switch.config in tftproot directory set the value to 'DEL tftproot/switch.config' NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { fileManagement 3 } fileSystemSpaceAvailable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This field displays the available space of the AMM file system." ::= { fileManagement 6 } -- ******************************************************************************** -- componentMonitors -- ******************************************************************************** componentMonitors OBJECT IDENTIFIER ::= { blades 37 } -- ******************************************************************************** -- componentMACAddressTable -- ******************************************************************************** componentMACAddressTable OBJECT-TYPE SYNTAX SEQUENCE OF ComponentMACAddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of MAC address VPD information for each component." ::= { componentMonitors 11 } componentMACAddressEntry OBJECT-TYPE SYNTAX ComponentMACAddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Component MAC address table entry" INDEX { componentMACAddressTopologyPath, componentMACAddressIndex } ::= { componentMACAddressTable 1 } ComponentMACAddressEntry ::= SEQUENCE { componentMACAddressTopologyPath OCTET STRING, componentMACAddressIndex INTEGER, componentMACAddressName OCTET STRING, componentMACAddress OCTET STRING } componentMACAddressTopologyPath OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..100)) ACCESS read-only STATUS mandatory DESCRIPTION "The unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree represents a component. The path to a particular component consists of one or more , pairs, where each successive pair is a child of the previous parent pair. As an example, the root of the tree is the chassis and is represented by the pair 'CHASSIS, 1'. This pair indicates the first instance of the chassis. If a blade is inserted in slot 4 of the chassis, its topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the components in the chassis can be determined along with their relative hierarchy to each other. Note that this TP is preceded by a single octet that specifies the TP length. This is required since this table is indexed with two indices and, therefore, the TP length must be explicitly provided. This component firmware table is indexed by this unique topology path and the numeric designations for the components are: CHASSIS, 0x01 Chassis MM, 0x02 Management Module BLADE, 0x03 Main system board of a blade POWER, 0x04 Power Supply, Power Module, etc COOLING, 0x05 Fan, blower, or other cooling device IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge MEDIA, 0x07 Media device PROCESSOR, 0x08 Any processor, processor module, etc STORAGE, 0x09 Any type of storage device EXPANSION, 0x0A Expansion Card (not covered by more specific type) MEMORY, 0x0B Any memory device, module, etc MFRU, 0x0C Managed FRU Device PANEL, 0x0D Any sort of panel device, such as a front panel BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc CARD_EXPANSION, 0x0F Expansion card, ie. daughter card CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card INTERPOSER, 0x11 Interposer device CLOCK, 0x12 Clock card MUX, 0x13 Mulitplexer card ADDIN, 0x14 cKVM card & other addin cards STORAGE_MODULE, 0x15 Container of one or more Storage Devices SYS_EXPANSION_CARD, 0x16 Management card BATTERY, 0x17 A single battery BATTERY_MODULE, 0x18 Container of one or more batteries REAR_LED, 0x19 Rear LED card MEMORY_BANK, 0x1A Memory banks AIR_FILTER, 0x1B Filter mechanism (bezel) SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports PARENT, 0x1D Reference to parent for multi-parent support PHY_PORT, 0x1E Physical port IO_EXPANDER, 0x1F RAID card CABLE, 0x20 Cable/Interconnect FAN_MUX 0x29 Fan multiplexer card" ::= { componentMACAddressEntry 1 } componentMACAddressIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Each component may have one or more MAC address VPD values associated with it, and this index object identifies the particular instance." ::= { componentMACAddressEntry 2 } componentMACAddressName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the component as a null terminated string." ::= { componentMACAddressEntry 3 } componentMACAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address VPD value for this component and index. The value is a null terminated string." ::= { componentMACAddressEntry 4 } -- ************************************************************************ -- FFDC Service -- ************************************************************************ serviceConfig OBJECT IDENTIFIER ::= { service 1 } debugEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS deprecated DESCRIPTION "Disable/Enable AMM debugging with USB key by service personnel." ::= { serviceConfig 3 } bladeServiceData OBJECT IDENTIFIER ::= { service 3 } bladeServiceDataTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeServiceDataEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade service data information." ::= { bladeServiceData 1 } bladeServiceDataEntry OBJECT-TYPE SYNTAX BladeServiceDataEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Blade service data entry" INDEX { serviceDataIndex } ::= { bladeServiceDataTable 1 } BladeServiceDataEntry ::= SEQUENCE { serviceDataIndex INTEGER, serviceDataBladeId INTEGER, serviceDataBladeExists INTEGER, serviceDataBladePowerState INTEGER, serviceDataBladeName OCTET STRING, serviceDataBladeCapability INTEGER, serviceDataDumpInitiate INTEGER, serviceDataDumpRetrieve INTEGER, serviceDataDumpCapabilityMask OCTET STRING, serviceDataDumpInProgress INTEGER } serviceDataIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Blade service date index." ::= { bladeServiceDataEntry 1 } serviceDataBladeId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { bladeServiceDataEntry 2 } serviceDataBladeExists OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the blade specified exists or not." ::= { bladeServiceDataEntry 3 } serviceDataBladePowerState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), standby(3), hibernate(4), unknown(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the blade specified is powered on or not. If the AMM is experiencing a communication problem with the blade, the state may be returned as unknown(255)" ::= { bladeServiceDataEntry 4 } serviceDataBladeName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name of the blade as a string." ::= { bladeServiceDataEntry 5 } serviceDataBladeCapability OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Indicates whether the blade has the capability to trigger service data. NOTE: This Mib object is deprecated and no longer supported. Please see serviceDataBladeCapabilityMask OID" ::= { bladeServiceDataEntry 6 } serviceDataDumpInitiate OBJECT-TYPE SYNTAX INTEGER { processorDump(1), platformDump(2), partitionDump(3), serviceData(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Initiates a type of dump collection to be initiated for the blade. NOTE: Not all blades support this, please check serviceDataDumpCapabilityMask OID to see if the action is supported on this blade. Only one file can be moved to the'/service' directory at a time, please look over fileManagement OID to check if the file has been compeleted. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { bladeServiceDataEntry 7 } serviceDataDumpRetrieve OBJECT-TYPE SYNTAX INTEGER { processorDump(1), platformDump(2), partitionDump(3), serviceData(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Retrieve a type of service data file from blade to AMM. NOTE: This OID only is valid for the last four bit mask designations listed in the serviceDataDumpCapabilityMask OID. Only one file can be moved to the '/service' directory at a time, please look over fileManagement OID to check if the file has been compeleted. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { bladeServiceDataEntry 8 } serviceDataDumpCapabilityMask OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the blade has the capability to trigger service data and if so, which operations are supported and whether the file can be transferred to the AMM from the blade. The values and meanings are as follows: 0000 0000 means this blade does not support any at all. 0000 0001 means this blade supports 'processor' type and the file remains on the blade. 0000 0010 means this blade supports 'platform' type and the file remains on the blade 0000 0100 means this blade supports 'partition' type and the file remians on the blade 0000 1000 means this blade supports 'processor' type and the file can be transferred to the AMM. 0001 0000 means this blade supports 'platform' type and the file can be transferred to the AMM. 0010 0000 means this blade supports 'partition' type and the file can be transferred to the AMM 0100 0000 means this blade supports 'serviceData' type and the file can be transferred to the AMM For example, the returned value of 01111000 means this blade supports 'processor','platform', 'partition' and 'serviceData' types, and the file can be transferred to the AMM" ::= { bladeServiceDataEntry 9 } serviceDataDumpInProgress OBJECT-TYPE SYNTAX INTEGER { inProgress(1), notInProgress(2), unknown(255) } ACCESS read-only STATUS mandatory DESCRIPTION "An indicator as to whether a blade dump is in progress for the specified blade. This object ONLY applies to dumps that can be triggered by the AMM and where the dump file is transferred to the AMM filesystem upon completion. See the serviceDataDumpCapabilityMask object for support levels. The flag that this MIB object represents will be set on when the IPMI command is sent to the blade indicating 'init dump' and will be cleared upon receiving the valid dump file from the blade or the creation of the text file indicating the problem encountered. If it cannot be determined if the dump is in progress, the unknown(255) value is returned." ::= { bladeServiceDataEntry 10 } bladeSystemReferenceCodes OBJECT IDENTIFIER ::= { bladeServiceData 3 } bladeSysRefCodesTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeSysRefCodesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of blade system reference codes." ::= { bladeSystemReferenceCodes 1 } bladeSysRefCodesEntry OBJECT-TYPE SYNTAX BladeSysRefCodesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Boot sequence entry" INDEX { sysRefCodeIndex } ::= { bladeSysRefCodesTable 1 } BladeSysRefCodesEntry ::= SEQUENCE { sysRefCodeIndex INTEGER, sysRefCodeBayNumber OCTET STRING, sysRefCodeSequence INTEGER, sysRefCode OCTET STRING, sysRefCodeTimestamp OCTET STRING } sysRefCodeIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "System reference codes index." ::= { bladeSysRefCodesEntry 1 } sysRefCodeBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The bay number of the blade which has the system reference code." ::= { bladeSysRefCodesEntry 2 } sysRefCodeSequence OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the blade specified exists or not." ::= { bladeSysRefCodesEntry 3 } sysRefCode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Unique ID and system reference code for the blade." ::= { bladeSysRefCodesEntry 4 } sysRefCodeTimestamp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Timestamp of system reference code for the blade." ::= { bladeSysRefCodesEntry 5 } bladeSysRefCodesDetailsTable OBJECT-TYPE SYNTAX SEQUENCE OF BladeSysRefCodesDetailsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of details of blade system reference codes." ::= { bladeSystemReferenceCodes 2 } bladeSysRefCodesDetailsEntry OBJECT-TYPE SYNTAX BladeSysRefCodesDetailsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Boot sequence entry" INDEX { sysRefCodeDetailIndex } ::= { bladeSysRefCodesDetailsTable 1 } BladeSysRefCodesDetailsEntry ::= SEQUENCE { sysRefCodeDetailIndex INTEGER, sysRefCodeDetailBayNumber OCTET STRING, sysRefCodeDetailSRCSequence INTEGER, sysRefCodeDetailSequence OCTET STRING, sysRefCodeDetailDataString OCTET STRING } sysRefCodeDetailIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "System reference codes index." ::= { bladeSysRefCodesDetailsEntry 1 } sysRefCodeDetailBayNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The bay number of the blade which has the details of system reference code." ::= { bladeSysRefCodesDetailsEntry 2 } sysRefCodeDetailSRCSequence OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A sequence of the system reference codes for the blade." ::= { bladeSysRefCodesDetailsEntry 3 } sysRefCodeDetailSequence OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A sequence of the detailed information of the system reference codes for the blade." ::= { bladeSysRefCodesDetailsEntry 4 } sysRefCodeDetailDataString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Detailed information of the system reference codes for the blade." ::= { bladeSysRefCodesDetailsEntry 5 } serviceAdvisor OBJECT IDENTIFIER ::= { service 4 } autoCallHomeSetup OBJECT IDENTIFIER ::= { serviceAdvisor 1 } acceptLicenseAgreement OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Accept Terms and Conditions of AMM Service Advisor. The user will have to accept the terms and conditions before Service Advisor can send diagnostic data to IBM support personnel. If AMM configuration is reset to defaults, the user will have to accept the terms and conditions again before they can enable Service Advisor. For more information, please refer to the IBM BladeCenter User's Guide. A GET of this object may return disabled(0) or enabled(1), depending upon the current state. However, only enabled(1) is accepted on a SET in order to accept the license agreement. A SET of disabled(0) will return noSuchValue and is not allowed." ::= {autoCallHomeSetup 1} serviceAdvisorEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable IBM Support. The User Agreement must be accepted and the contact information must be set before the IBM Support function of Service Advisor can be enabled." ::= {autoCallHomeSetup 2} serviceSupportCenter OBJECT IDENTIFIER ::= {serviceAdvisor 2} ibmSupportCenter OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The country code for the IBM Support Center. 2 character ISO country code." ::= {serviceSupportCenter 1} contactInformation OBJECT IDENTIFIER ::= {serviceAdvisor 3} companyName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " The organization/company name of the contact person. 1-30 characters." ::= {contactInformation 1} contactName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The name of the contact person.1-30 characters." ::= {contactInformation 2} phoneNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The phone of the contact person. 5-30 characters." ::= {contactInformation 3} emailAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The email of the contact person. It must contain '@' and dot '.' in form userid@hostname (50 characters maximum). The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters. The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items. Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters." ::= {contactInformation 4} address OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The address of the machine location. The information in this field should be of sufficient detail to allow someone to quickly find the chassis when necessary. 1-30 characters." ::= {contactInformation 5} city OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The city of the machine location. 1-30 characters." ::= {contactInformation 6} state OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The state of the machine location. 2-3 characters." ::= {contactInformation 7} postalCode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The postal code of the location for this system. 1-9 characters, only alphanumeric characters are valid." ::= {contactInformation 8} phoneNumberExt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The extension of the phone. 30 characters maximum." ::= {contactInformation 10} altContactName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "(Optional) The name of the alternate contact person.1-30 characters." ::= {contactInformation 11} altPhoneNumber OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "(Optional) The phone of the alternate contact person. 5-30 characters." ::= {contactInformation 12} altPhoneNumberExt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "(Optional) The extension of the alternate phone. 30 characters maximum." ::= {contactInformation 13} altEmailAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "(Optional) The email of the alternate contact person. It must contain '@' and dot '.' in form userid@hostname (50 characters maximum). The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters. The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items. Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters." ::= {contactInformation 14} machineLocPhone OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "(Optional) The contact phone number of the machine location. 5-30 characters." ::= {contactInformation 15} httpProxyConfig OBJECT IDENTIFIER ::= {serviceAdvisor 4} httpProxyEnable OBJECT-TYPE SYNTAX INTEGER{ disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable of the HTTP Proxy. Select Enable to use the proxy for call home connections from the AMM to IBM. HTTP Proxy is used by the AMM when it is not connected to the internet directly." ::= {httpProxyConfig 1} httpProxyLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Fully qualified host name or IP address of the HTTP Proxy. Maximum of 63 characters." ::= {httpProxyConfig 2} httpProxyPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The port number of the HTTP Proxy. An integer value from 1 to 65535." ::= {httpProxyConfig 3} httpProxyUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "User Name of the HTTP Proxy. A maximum of 30 characters string without spaces." ::= {httpProxyConfig 4} httpProxyPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Password of the HTTP Proxy. A maximum of 15 characters string without spaces." ::= {httpProxyConfig 5} activityLogs OBJECT IDENTIFIER ::= { serviceAdvisor 5} activityLogTable OBJECT-TYPE SYNTAX SEQUENCE OF ActivityLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Table of Service Advisor Activity Log entries information. This table displays the last five events that were generated by the system or user that are called home. The entries are displayed in reverse chronological order (most recent call home entry first). For any events that happen with same Date/Time, only one event will be called home. If a call home event that is already in the activity log is triggered again on the same event source, it will not be called home again unless the prior entry has been acknowledged as corrected or 120 hours (5 days) have passed since it initially occurred and was called home. " ::= { activityLogs 1 } activityLogEntry OBJECT-TYPE SYNTAX ActivityLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " Activity Log table entry. Each entry has the result of the call-home attempt, the service number assigned for the issue by IBM support, the event ID, event source, date and time that event occured, and a text message. " INDEX { activityLogIndex } ::= { activityLogTable 1 } ActivityLogEntry ::= SEQUENCE { activityLogIndex INTEGER, activityLogString OCTET STRING, activityLogAcknowledge INTEGER, activityLogAttribute OCTET STRING } activityLogIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Activity Log index number. For consistent results, view as a table and not as individual entries." ::= { activityLogEntry 1 } activityLogString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string of data detailing one Activity Log entry. The text message is from the original entry in the event log. For consistent results, view as a table and not as individual entries." ::= { activityLogEntry 2 } activityLogAcknowledge OBJECT-TYPE SYNTAX INTEGER{ no(0), yes(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The acknowledgement of one Activity Log entry as corrected. This field allows the users to set a reminder next to certain events to indicate their awareness of the issue. Checking the acknowledge flag will not cause the event to be removed from the log or close the ticket at IBM support. This log is not cleared, so the acknowledge flag can be used to indicate a problem can be ignored. This field can be also used to override the 120 hour (5 day) filtering of reports via IBM Support or FTP/TFTP Server of Service Data. For consistent results, view as a table and not as individual entries." ::= { activityLogEntry 3 } activityLogAttribute OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION " A string of data detailing one Activity Log entry's attribute. It contains states of both calling IBM support and FTP/TFTP Server. A PENDING indicates that the system is preparing for the event to be called home by collecting data about the systems state. A SUCCESS state indicates that the problem was successfully transmitted to IBM support or FTP/TFTP Server. A DISABLED state indicates that Service Advisor has disabled calling IBM Support or FTP/TFTP Server while the hardware event is detected. A NOT SENT state indicates that the serviceable event was not sent to prevent the same event from being sent repeatedly. The FAILED state indicates that the attempt to transmit the event information was not successful. Additional information may be found in the Event Log. The service number is similar to a ticket number that can be used as a reference to the issue reported by the machine when contacting IBM support. The event ID, event source, date and time are all information from the original entry in the event log. The acknowledged as corrected field is a reminder to certain events to indicate their awareness of the issue. For consistent results, view as a table and not as individual entries." ::= { activityLogEntry 4 } -- ******************************************************************************** -- autoftp -- ******************************************************************************** -- autoFTPSetup OBJECT IDENTIFIER ::= { service 5 } autoFTPCallMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), ftp(1), tftp(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This field specifies the automated problem reporting mode. Automated problem reporting mode allows the AMM to automatically put service data to a specified server when a call home event is detected. For any call home events that happen with same Date/Time, only one event will be reported. The system will also wait for an interval of 120 hours (5 days) before another identical event can be sent for the same failed component." ::= { autoFTPSetup 1 } autoFTPCallAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This field specifies the remote server address of FTP and TFTP. It should be fully qualified hostname or IP address." ::= { autoFTPSetup 2 } autoFTPCallPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This field specifies the port on remote FTP/TFTP server for data transmission." ::= { autoFTPSetup 3 } autoFTPCallUserID OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This field specifies the user account to login remote FTP server." ::= { autoFTPSetup 4 } autoFTPCallPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This field specifies the password to login remote FTP server." ::= { autoFTPSetup 5 } -- ******************************************************************************** -- Call Home Exclusion List -- ******************************************************************************** callHomeExclusionEvents OBJECT IDENTIFIER ::= { service 6} readCallHomeExclusionEventTable OBJECT-TYPE SYNTAX SEQUENCE OF ReadCallHomeExclusionEventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Call Home Exclusion Event entries information." ::= { callHomeExclusionEvents 1 } readCallHomeExclusionEventEntry OBJECT-TYPE SYNTAX ReadCallHomeExclusionEventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Call Home Exclusion Event table entry" INDEX { readCallHomeExclusionEventIndex } ::= { readCallHomeExclusionEventTable 1 } ReadCallHomeExclusionEventEntry ::= SEQUENCE { readCallHomeExclusionEventIndex INTEGER, readCallHomeExclusionEventID OCTET STRING } readCallHomeExclusionEventIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index number of one Call Home Exclusion Event. For consistent results, view as a table and not as individual entries." ::= { readCallHomeExclusionEventEntry 1 } readCallHomeExclusionEventID OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The Event ID of one Call Home Exclusion Event entry. For consistent results, view as a table and not as individual entries." ::= { readCallHomeExclusionEventEntry 2 } addCallHomeExclusionEvent OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Add one call home Event ID into the Call Home Exclusion List. The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. If Service Advisor Terms and Conditions are accepted, an event can be added into the exclusion list. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { callHomeExclusionEvents 2} rmCallHomeExclusionEvent OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Remove one call home Event ID from the Call Home Exclusion List. The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. If Service Advisor Terms and Conditions are accepted, an event on the exclusion list can be removed. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { callHomeExclusionEvents 3} rmAllCallHomeExclusionEvent OBJECT-TYPE SYNTAX INTEGER { execute(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Remove all Event IDs from the Call Home Exclusion List. If Service Advisor Terms and Conditions are accepted, events on the exclusion list can be removed. NOTE: Value returned for the GET command is meaningless for this MIB object." ::= { callHomeExclusionEvents 4} -- ************************************************************************* -- Scalable Complex Information -- ************************************************************************* scalableComplexTable OBJECT-TYPE SYNTAX SEQUENCE OF ScalableComplexEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of scalable complex information. This table provides information and control actions related to the scalable complexes installed in the chassis. Partition, node and port information and control are defined in their own tables." ::= { scaling 1 } scalableComplexEntry OBJECT-TYPE SYNTAX ScalableComplexEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Scalable complex information." INDEX { scalableComplexIdentifier } ::= { scalableComplexTable 1 } ScalableComplexEntry ::= SEQUENCE { scalableComplexIdentifier INTEGER, scalableComplexNumPartitions INTEGER, scalableComplexNumNodes INTEGER, scalableComplexPartStartSlot INTEGER, scalableComplexPartNumNodes INTEGER, scalableComplexAction INTEGER } scalableComplexIdentifier OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unique numeric identifier for a complex installed in the chassis." ::= { scalableComplexEntry 1 } scalableComplexNumPartitions OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of partitions currently defined for this complex." ::= { scalableComplexEntry 2 } scalableComplexNumNodes OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of nodes existing in this complex, regardless of their assignment to any given partition. The physical slot location of the nodes can be determined from the scalableComplexNodeTable." ::= { scalableComplexEntry 3 } scalableComplexPartStartSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The lowest slot number occupied by the nodes in the new partition that is being created via the scalableComplexAction=create(3) action. This object must be set prior to triggering the partition creation." ::= { scalableComplexEntry 4 } scalableComplexPartNumNodes OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of nodes to be included in the new partition that is being created via the scalableComplexAction=create(3) action. This object must be set prior to triggering the partition creation." ::= { scalableComplexEntry 5 } scalableComplexAction OBJECT-TYPE SYNTAX INTEGER { clear(1), autocreate(2), create(3) } ACCESS write-only STATUS mandatory DESCRIPTION "This object allows various actions to be taken in relation to a particular complex. clear(1) - This clears all partition information related to the complex. Any nodes associated with the complex are no longer assigned to any partitions. All nodes in the complex must be powered off prior to attempting this operation, otherwise, the action will fail. autocreate(2) - This creates a single partition which includes all nodes associated with the complex. Any other prior partition definitions must be deleted prior to issuing this action, otherwise, the action will fail. create(3) - This allows the creation of a partition within the complex. Prior to triggering this action, the scalableComplexPartStartSlot and scalableComplexPartNumNodes objects must be set first to identify the starting slot number and number of nodes to be included in this new partition. The nodes chosen for inclusion in this new partition must not be part of another existing partition, otherwise, the action will fail." ::= { scalableComplexEntry 6 } -- ************************************************************************* -- Scalable Complex Partition Information -- ************************************************************************* scalableComplexPartitionTable OBJECT-TYPE SYNTAX SEQUENCE OF ScalableComplexPartitionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of scalable complex partition information. This table provides information and control actions related to the partitions defined across all of the complexes installed in the chassis. Complex, node and port information and control are defined in their own tables." ::= { scaling 2 } scalableComplexPartitionEntry OBJECT-TYPE SYNTAX ScalableComplexPartitionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Scalable complex partition information." INDEX { scalableComplexId, scalableComplexPartitionIdentifier } ::= { scalableComplexPartitionTable 1 } ScalableComplexPartitionEntry ::= SEQUENCE { scalableComplexId INTEGER, scalableComplexPartitionIdentifier INTEGER, scalableComplexPartitionMode INTEGER, scalableComplexPartitionNumNodes INTEGER, scalableComplexPartitionStatus INTEGER, scalableComplexPartitionAction INTEGER } scalableComplexId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unique numeric identifier for a complex installed in the chassis." ::= { scalableComplexPartitionEntry 1 } scalableComplexPartitionIdentifier OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unique numeric identifier for a partition defined within a complex installed in the chassis." ::= { scalableComplexPartitionEntry 2 } scalableComplexPartitionMode OBJECT-TYPE SYNTAX INTEGER { partition(1), standalone(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The currently configured mode of this partition. It is recommended that a partition be powered off prior to modification of the mode. In addition, switching a partition mode to stand-alone will cause subsequent partition actions to be ignored until the partition mode is restored." ::= { scalableComplexPartitionEntry 3 } scalableComplexPartitionNumNodes OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of nodes currently defined for this partition." ::= { scalableComplexPartitionEntry 4 } scalableComplexPartitionStatus OBJECT-TYPE SYNTAX INTEGER { poweredoff(1), poweredon(2), resetting(3), invalid(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The current power status of this partition when the partition has a valid partition configuration. However, in the event the partition reports a partition consitency check problem, the invalid state is provided." ::= { scalableComplexPartitionEntry 5 } scalableComplexPartitionAction OBJECT-TYPE SYNTAX INTEGER { delete(1), poweron(2), poweroff(3), powercycle(4) } ACCESS write-only STATUS mandatory DESCRIPTION "This object allows various actions to be taken in relation to a particular partition in a given complex. delete(1) - Deletes the partition from the complex. All nodes in the partition must be powered off prior to attempting this operation, otherwise, the action will fail. poweron(2) - Powers up a powered off partition poweroff(3) - Powers off an already powered on partition powercycle(4) - Power cycles a partition" ::= { scalableComplexPartitionEntry 6 } -- ************************************************************************* -- Scalable Complex Node Information -- ************************************************************************* scalableComplexNodeTable OBJECT-TYPE SYNTAX SEQUENCE OF ScalableComplexNodeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of scalable complex node information. This table provides information and control actions related to the nodes installed in the chassis. Complex, partition and port information and control are defined in their own tables." ::= { scaling 3 } scalableComplexNodeEntry OBJECT-TYPE SYNTAX ScalableComplexNodeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Scalable complex node information." INDEX { scalableComplexNodeSlot } ::= { scalableComplexNodeTable 1 } ScalableComplexNodeEntry ::= SEQUENCE { scalableComplexNodeSlot INTEGER, scalableComplexNodeName OCTET STRING, scalableComplexNodeType INTEGER, scalableComplexNodeResources OCTET STRING, scalableComplexNodeRole INTEGER, scalableComplexNodeState INTEGER, scalableComplexNodeUUID OCTET STRING, scalableComplexNodeSerialNum OCTET STRING, scalableComplexNodeNumPorts INTEGER, scalableComplexNodeComplexID INTEGER, scalableComplexNodePartitionID INTEGER, scalableComplexNodeLogicalID INTEGER, scalableComplexNodeAction INTEGER } scalableComplexNodeSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The base slot number where the node exists in the chassis." ::= { scalableComplexNodeEntry 1 } scalableComplexNodeName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(256)) ACCESS read-only STATUS mandatory DESCRIPTION "The description string which uniquely identifies the blade." ::= { scalableComplexNodeEntry 2 } scalableComplexNodeType OBJECT-TYPE SYNTAX INTEGER { processor(1), memory(2), io(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The general categorization of the node." ::= { scalableComplexNodeEntry 3 } scalableComplexNodeResources OBJECT-TYPE SYNTAX OCTET STRING (SIZE(256)) ACCESS read-only STATUS mandatory DESCRIPTION "A string providing a summary overview of the resources provided by this node." ::= { scalableComplexNodeEntry 4 } scalableComplexNodeRole OBJECT-TYPE SYNTAX INTEGER { primary(1), secondary(2), unassigned(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if the node is assigned to a partition, and if so, provides an indication of whether the node is the primary node of the partition or not." ::= { scalableComplexNodeEntry 5 } scalableComplexNodeState OBJECT-TYPE SYNTAX INTEGER { poweredoff(1), poweredon(2), resetting(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The physical power state of this node." ::= { scalableComplexNodeEntry 6 } scalableComplexNodeUUID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(256)) ACCESS read-only STATUS mandatory DESCRIPTION "The Universally Unique IDentifier (UUID) of this node, represented as a 16 byte hex number." ::= { scalableComplexNodeEntry 7 } scalableComplexNodeSerialNum OBJECT-TYPE SYNTAX OCTET STRING (SIZE(256)) ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this node." ::= { scalableComplexNodeEntry 8 } scalableComplexNodeNumPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of remote nodes that this node has links to." ::= { scalableComplexNodeEntry 9 } scalableComplexNodeComplexID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "For an assigned node, the identifier of the complex this node is related to. For an unassigned node, this object has no meaning." ::= { scalableComplexNodeEntry 10 } scalableComplexNodePartitionID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "For an assigned node, the identifier of the partition this node is related to. For an unassigned node, this object has no meaning." ::= { scalableComplexNodeEntry 11 } scalableComplexNodeLogicalID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unique numeric identifier for this node, unique within the partition." ::= { scalableComplexNodeEntry 12 } scalableComplexNodeAction OBJECT-TYPE SYNTAX INTEGER { poweroff(1), poweron(2) } ACCESS write-only STATUS mandatory DESCRIPTION "The actions that can be applied to an unassigned node. The current state is provided by the scalableComplexNodeState object." ::= { scalableComplexNodeEntry 14 } -- ************************************************************************* -- Scalable Complex Node Port Information -- ************************************************************************* scalableComplexNodePortTable OBJECT-TYPE SYNTAX SEQUENCE OF ScalableComplexNodePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of scalable complex node port information which provides details related to the port connectivity. Complex, partition and node information and control are defined in their own tables." ::= { scaling 4 } scalableComplexNodePortEntry OBJECT-TYPE SYNTAX ScalableComplexNodePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Scalable complex node port information." INDEX { scalableComplexNodePortSlot, scalableComplexNodePortNum } ::= { scalableComplexNodePortTable 1 } ScalableComplexNodePortEntry ::= SEQUENCE { scalableComplexNodePortSlot INTEGER, scalableComplexNodePortNum INTEGER, scalableComplexNodePortRemChkSum INTEGER, scalableComplexNodePortRemNum INTEGER, scalableComplexNodePortStatus INTEGER, scalableComplexNodePortType INTEGER } scalableComplexNodePortSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The base slot number where the node exists in the chassis." ::= { scalableComplexNodePortEntry 1 } scalableComplexNodePortNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number of a port on this node. Note that this port number is 0-based, but since it is used as the table index (0 is not allowed), it will be presented as one more than the actual port number." ::= { scalableComplexNodePortEntry 2 } scalableComplexNodePortRemChkSum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The checksum of the remote port, used as a port identifier." ::= { scalableComplexNodePortEntry 3 } scalableComplexNodePortRemNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The zero-based port number of the remote port." ::= { scalableComplexNodePortEntry 4 } scalableComplexNodePortStatus OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2), unknown(255) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of the port." ::= { scalableComplexNodePortEntry 5 } scalableComplexNodePortType OBJECT-TYPE SYNTAX INTEGER { qpi(1), exa(2), unknown(255) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type." ::= { scalableComplexNodePortEntry 6 } END