IBM-Director-Alert-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32 FROM SNMPv2-SMI DisplayString, TruthValue FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF SnmpAdminString FROM SNMP-FRAMEWORK-MIB; ibm OBJECT IDENTIFIER ::= { enterprises 2 } ibmProd OBJECT IDENTIFIER ::= { ibm 6 } director OBJECT IDENTIFIER ::= { ibmProd 159 } description OBJECT IDENTIFIER ::= { director 202 } details OBJECT IDENTIFIER ::= { director 9696 } directorTraps MODULE-IDENTITY LAST-UPDATED "200404210000Z" ORGANIZATION "IBM Corp." CONTACT-INFO "IBM Corporation" DESCRIPTION "This MIB is for use with the Event Action Plan Builder of IBM Director." REVISION "200404210000Z" DESCRIPTION "This MIB was revised to include traps for more possible events generated by the IBM Director event subsystem." REVISION "200307090000Z" DESCRIPTION "The initial version of this MIB." ::= { director 201 } -- -- Generic trap for events -- generalEvent NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory } STATUS current DESCRIPTION "This is a IBM Director event converted into an SNMP trap. This trap is only used for events with no mapping." ::= { directorTraps 2 } -- -- Topology traps -- directorFamily OBJECT IDENTIFIER ::= { directorTraps 1 } topology OBJECT IDENTIFIER ::= { directorFamily 1 } online NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory } STATUS current DESCRIPTION "The managed object's state has changed to online." ::= { topology 1 } offline NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory } STATUS current DESCRIPTION "The managed object's state has changed to offline." ::= { topology 2 } create NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory } STATUS current DESCRIPTION "The managed object has been created." ::= { topology 3 } change NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory } STATUS current DESCRIPTION "The managed object has changed." ::= { topology 4 } destroy NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory } STATUS current DESCRIPTION "The managed object has been destroyed." ::= { topology 5 } -- -- Director Agent traps -- directorAgent OBJECT IDENTIFIER ::= { directorFamily 2 } processMonitor NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, actualValue, duration, monitorResource, thresholdName, thresholdValue } STATUS current DESCRIPTION "The process monitor threshold has generated an event." ::= { directorAgent 1 } cpuMonitors OBJECT IDENTIFIER ::= { directorAgent 2 } cpuUtilization NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, actualValue, duration, monitorResource, thresholdName, thresholdValue } STATUS current DESCRIPTION "The CPU utilization monitor threshold has generated an event." ::= { cpuMonitors 1 } processCount NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, actualValue, duration, monitorResource, thresholdName, thresholdValue } STATUS current DESCRIPTION "The process count monitor threshold has generated an event." ::= { cpuMonitors 2 } diskMonitors OBJECT IDENTIFIER ::= { directorAgent 3 } driveSpaceUsed NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, actualValue, duration, monitorResource, thresholdName, thresholdValue } STATUS current DESCRIPTION "The drive space used monitor threshold has generated an event." ::= { diskMonitors 1 } driveSpaceUsedPercent NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, actualValue, duration, monitorResource, thresholdName, thresholdValue } STATUS current DESCRIPTION "The percentage of drive space used monitor threshold has generated an event." ::= { diskMonitors 2 } driveSpaceRemaining NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, actualValue, duration, monitorResource, thresholdName, thresholdValue } STATUS current DESCRIPTION "The drive space remaining monitor threshold has generated an event." ::= { diskMonitors 3 } driveWorkload NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, actualValue, duration, monitorResource, thresholdName, thresholdValue } STATUS current DESCRIPTION "The drive workload monitor threshold has generated an event." ::= { diskMonitors 4 } memoryMonitors OBJECT IDENTIFIER ::= { directorAgent 4 } lockedMemory NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, actualValue, duration, monitorResource, thresholdName, thresholdValue } STATUS current DESCRIPTION "The locked memory monitor threshold has generated an event." ::= { memoryMonitors 1 } memoryUsage NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, actualValue, duration, monitorResource, thresholdName, thresholdValue } STATUS current DESCRIPTION "The memory usage monitor threshold has generated an event." ::= { memoryMonitors 2 } nicMonitors OBJECT IDENTIFIER ::= { directorAgent 5 } -- Add nic monitors here ntPerfMonitors OBJECT IDENTIFIER ::= { directorAgent 6 } totalPrivilegedTimePercent NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, actualValue, duration, monitorResource, thresholdName, thresholdValue } STATUS current DESCRIPTION "The percentage of total privileged time monitor threshold has generated an event." ::= { ntPerfMonitors 1 } fileReadOperationsPerSec NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, actualValue, duration, monitorResource, thresholdName, thresholdValue } STATUS current DESCRIPTION "The files read per second monitor threshold has generated an event." ::= { ntPerfMonitors 2 } -- thread NOTIFICATION-TYPE -- OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory } -- STATUS current -- DESCRIPTION -- "" --::= { ntPerfMonitor 3 } tcpipMonitors OBJECT IDENTIFIER ::= { directorAgent 7 } udpPacketsSentPerSec NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, actualValue, duration, monitorResource, thresholdName, thresholdValue } STATUS current DESCRIPTION "A threshold event for the number of UDP packets sent per second." ::= { tcpipMonitors 1 } udpPacketsReceivedPerSec NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, actualValue, duration, monitorResource, thresholdName, thresholdValue } STATUS current DESCRIPTION "A threshold event for the number of UDP packets received per second." ::= { tcpipMonitors 2 } ipPacketsSentPerSec NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, actualValue, duration, monitorResource, thresholdName, thresholdValue } STATUS current DESCRIPTION "A threshold event for the number of IP packets sent per second." ::= { tcpipMonitors 3 } ipPacketsReceivedPerSec NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, actualValue, duration, monitorResource, thresholdName, thresholdValue } STATUS current DESCRIPTION "A threshold event for the number of IP packets received per second." ::= { tcpipMonitors 4 } ipErrorPacketsReceivedPerSec NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, actualValue, duration, monitorResource, thresholdName, thresholdValue } STATUS current DESCRIPTION "A threshold event for the number of IP packets received with errors per second." ::= { tcpipMonitors 5 } tcpConnections NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, actualValue, duration, monitorResource, thresholdName, thresholdValue } STATUS current DESCRIPTION "A threshold event for the number of TCP connections." ::= { tcpipMonitors 6 } monitorEventDetails OBJECT IDENTIFIER ::= { directorAgent 8 } actualValue OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The actual value of the monitor." ::= { monitorEventDetails 1 } duration OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The duration of this monitor." ::= { monitorEventDetails 2 } monitorResource OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The monitor resource." ::= { monitorEventDetails 3 } thresholdName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the monitor threshold." ::= { monitorEventDetails 4 } thresholdValue OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the monitor threshold." ::= { monitorEventDetails 5 } -- -- Test trap -- test OBJECT IDENTIFIER ::= { directorFamily 3 } action NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory } STATUS current DESCRIPTION "The test action event. An internally generated event for the purpose of testing the action configuration." ::= { test 1 } -- -- Console traps -- console OBJECT IDENTIFIER ::= { directorFamily 4 } consoleEventDetails OBJECT IDENTIFIER ::= { console 1 } userID OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The console user ID." ::= { consoleEventDetails 1 } address OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The console address." ::= { consoleEventDetails 2 } userName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The console username." ::= { consoleEventDetails 3 } userDescription OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The console username's description." ::= { consoleEventDetails 4 } userLocale OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The console user's locale." ::= { consoleEventDetails 5 } logonFailure OBJECT IDENTIFIER ::= { console 2 } badPassword NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, userID, address } STATUS current DESCRIPTION "When attempting to logon to the console, a bad password was used." ::= { logonFailure 1 } badUserID NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, userID, address } STATUS current DESCRIPTION "When attempting to logon to the console, a bad user ID was used." ::= { logonFailure 2 } disabledUserID NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, userID, address } STATUS current DESCRIPTION "When attempting to logon to the console, a disabled user ID was used." ::= { logonFailure 3 } downlevelConsole NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, userID, address } STATUS current DESCRIPTION "When attempting to logon to the console, a downlevel console was used." ::= { logonFailure 4 } expiredPassword NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, userID, address } STATUS current DESCRIPTION "When attempting to logon to the console, an expired password was used." ::= { logonFailure 5 } tooManyActiveIDs NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, userID, address } STATUS current DESCRIPTION "When attempting to logon to the console, too many IDs were active." ::= { logonFailure 6 } tooManyActiveLogons NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, userID, address } STATUS current DESCRIPTION "When attempting to logon to the console, too many logons were active." ::= { logonFailure 7 } uplevelConsole NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, userID, address } STATUS current DESCRIPTION "When attempting to logon to the console, an uplevel console was used." ::= { logonFailure 8 } logoff NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, userID, address, userName, userDescription, userLocale } STATUS current DESCRIPTION "A user has logged off the console." ::= { console 3 } logon NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, userID, address, userName, userDescription, userLocale } STATUS current DESCRIPTION "A user has logged on the console." ::= { console 4 } -- -- CIM traps -- cimFamily OBJECT IDENTIFIER ::= { directorTraps 3 } windowsNTEventLog OBJECT IDENTIFIER ::= { cimFamily 1 } windowsNTEventLogEventDetails OBJECT IDENTIFIER ::= { windowsNTEventLog 1 } category OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Windows Event Log category." ::= { windowsNTEventLogEventDetails 1 } categoryString OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The Windows Event Log category string." ::= { windowsNTEventLogEventDetails 2 } computerName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The computer name of the Windows Event Log event." ::= { windowsNTEventLogEventDetails 3 } data OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The Windows Event Log data for the event." ::= { windowsNTEventLogEventDetails 4 } eventLogCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Windows Event Log numeric event ID." ::= { windowsNTEventLogEventDetails 5 } eventLogIdentifier OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Windows Event Log numeric event identifier." ::= { windowsNTEventLogEventDetails 6 } eventLogType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Windows Event Log numeric event type." ::= { windowsNTEventLogEventDetails 7 } insertionStrings OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The Windows Event Log insertion strings." ::= { windowsNTEventLogEventDetails 8 } logFile OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The Windows Event Log file name." ::= { windowsNTEventLogEventDetails 9 } message OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The Windows Event Log message string." ::= { windowsNTEventLogEventDetails 10 } recordNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Windows Event Log record number." ::= { windowsNTEventLogEventDetails 11 } sourceName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The Windows Event Log source name." ::= { windowsNTEventLogEventDetails 12 } type OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The Windows Event Log type." ::= { windowsNTEventLogEventDetails 13 } user OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The Windows Event Log user." ::= { windowsNTEventLogEventDetails 14 } applicationLog NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, category, categoryString, computerName, data, eventLogCode, eventLogIdentifier, eventLogType, insertionStrings, logFile, message, recordNumber, sourceName, type, user } STATUS current DESCRIPTION "The Windows NT application event log has changed." ::= { windowsNTEventLog 2 } securityLog NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, category, categoryString, computerName, data, eventLogCode, eventLogIdentifier, eventLogType, insertionStrings, logFile, message, recordNumber, sourceName, type, user } STATUS current DESCRIPTION "The Windows NT application security log has changed." ::= { windowsNTEventLog 3 } systemLog NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory } STATUS current DESCRIPTION "The Windows NT application system log has changed." ::= { windowsNTEventLog 4 } windowsNTService OBJECT IDENTIFIER ::= { cimFamily 2 } windowsNTServiceEventDetails OBJECT IDENTIFIER ::= { windowsNTService 1 } acceptPause OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Whether this service accepts the pause state change." ::= { windowsNTServiceEventDetails 1 } acceptStop OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Whether this service accepts the stop state change." ::= { windowsNTServiceEventDetails 2 } caption OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The caption string for this service." ::= { windowsNTServiceEventDetails 3 } checkPoint OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The service's check point." ::= { windowsNTServiceEventDetails 4 } creationClassName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The creation class name for the service." ::= { windowsNTServiceEventDetails 5 } serviceDescription OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The description of the service." ::= { windowsNTServiceEventDetails 6 } desktopInteract OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Whether the service interacts with the desktop." ::= { windowsNTServiceEventDetails 7 } displayName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The displayable name for the service." ::= { windowsNTServiceEventDetails 8 } errorControl OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The error control value for the service." ::= { windowsNTServiceEventDetails 9 } exitCode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The exit code of the process for the service." ::= { windowsNTServiceEventDetails 10 } name OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the service." ::= { windowsNTServiceEventDetails 11 } pathName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The path name for the service." ::= { windowsNTServiceEventDetails 12 } processId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The process ID of the running service." ::= { windowsNTServiceEventDetails 13 } serviceSpecificExitCode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The specific exit code for the service." ::= { windowsNTServiceEventDetails 14 } serviceType OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The type of service." ::= { windowsNTServiceEventDetails 15 } startMode OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The start mode for the service." ::= { windowsNTServiceEventDetails 16 } startName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The start name for the service." ::= { windowsNTServiceEventDetails 17 } started OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Whether this service has started." ::= { windowsNTServiceEventDetails 18 } serviceState OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The state of the service." ::= { windowsNTServiceEventDetails 19 } status OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the service." ::= { windowsNTServiceEventDetails 20 } systemCreationClassName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The system creation class name for the service." ::= { windowsNTServiceEventDetails 21 } systemName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The system name for the service." ::= { windowsNTServiceEventDetails 22 } tagId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The tag ID of the service." ::= { windowsNTServiceEventDetails 23 } waitHint OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the wait hint for the service." ::= { windowsNTServiceEventDetails 24 } startedService NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, acceptPause, acceptStop, caption, checkPoint, creationClassName, serviceDescription, desktopInteract, displayName, errorControl, exitCode, name, pathName, processId, serviceSpecificExitCode, serviceType, startMode, startName, started, serviceState, status, systemCreationClassName, systemName, tagId, waitHint } STATUS current DESCRIPTION "A Windows NT service has started." ::= { windowsNTService 2 } stoppedService NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, acceptPause, acceptStop, caption, checkPoint, creationClassName, serviceDescription, desktopInteract, displayName, errorControl, exitCode, name, pathName, processId, serviceSpecificExitCode, serviceType, startMode, startName, started, serviceState, status, systemCreationClassName, systemName, tagId, waitHint } STATUS current DESCRIPTION "A Windows NT service has stopped." ::= { windowsNTService 3 } windowsRegistry OBJECT IDENTIFIER ::= { cimFamily 3 } windowsRegistryEventDetails OBJECT IDENTIFIER ::= { windowsRegistry 1 } hive OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The Windows Registry hive for this event." ::= { windowsRegistryEventDetails 1 } rootPath OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The Windows Registry root path for this event." ::= { windowsRegistryEventDetails 2 } securityDescriptor OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The Windows Registry security descriptor for this event." ::= { windowsRegistryEventDetails 3 } timeCreated OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The time this item was created in the Windows Registry." ::= { windowsRegistryEventDetails 4 } softwareTreeChanged NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, hive, rootPath, securityDescriptor, timeCreated } STATUS current DESCRIPTION "The Windows software tree section of the registry has changed." ::= { windowsRegistry 2 } systemTreeChanged NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, hive, rootPath, securityDescriptor, timeCreated } STATUS current DESCRIPTION "The Windows system tree section of the registry has changed." ::= { windowsRegistry 3 } -- -- MPA traps -- mpaFamily OBJECT IDENTIFIER ::= { directorTraps 4 } mpaEventDetails OBJECT IDENTIFIER ::= { mpaFamily 1 } alertCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The alert code." ::= { mpaEventDetails 1 } busId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The bus ID." ::= { mpaEventDetails 2 } componentId OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The component ID." ::= { mpaEventDetails 3 } firmwareCode OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The firmware identification code." ::= { mpaEventDetails 4 } ipAddress1 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The first IP address." ::= { mpaEventDetails 5 } ipAddress2 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The second IP address." ::= { mpaEventDetails 6 } issue OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The issue for the event." ::= { mpaEventDetails 7 } powerDomain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The domain of the power supply." ::= { mpaEventDetails 8 } reason OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The reason for the event." ::= { mpaEventDetails 9 } scsiId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the SCSI device." ::= { mpaEventDetails 10 } side OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The side in which the event occured." ::= { mpaEventDetails 11 } newState OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The new state." ::= { mpaEventDetails 12 } temperatureSensor OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The current temperature." ::= { mpaEventDetails 13 } threshold OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The threshold for the event." ::= { mpaEventDetails 14 } universalUniqueId OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The universal unique ID." ::= { mpaEventDetails 15 } senderUniversalUniqueId OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The universal unique ID of the sender." ::= { mpaEventDetails 16 } sourceUniversalUniqueId OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The universal unique ID of the source." ::= { mpaEventDetails 17 } unitNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The unit number." ::= { mpaEventDetails 18 } voltageSensor OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage sensor." ::= { mpaEventDetails 19 } component OBJECT IDENTIFIER ::= { mpaFamily 2 } bladeServer OBJECT IDENTIFIER ::= { component 1 } coD OBJECT IDENTIFIER ::= { bladeServer 1 } codEnabled NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The CoD has been enabled." ::= { coD 1 } bladeServerCommunication NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "Communication with a blade has been established." ::= { bladeServer 2 } bladeServerInserted NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "A blade has been inserted." ::= { bladeServer 3 } bladeServerRemoved NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "A blade has been removed." ::= { bladeServer 4 } bus OBJECT IDENTIFIER ::= { component 2 } busCommunication NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, busId, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "Communication with a bus has been established." ::= { bus 1 } chassis OBJECT IDENTIFIER ::= { component 3 } chassisConfiguration NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, componentId, firmwareCode, issue, powerDomain, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "The blade chassis configuration has changed." ::= { chassis 1 } chassisFailed NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, issue, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The blade chassis has failed." ::= { chassis 2 } dasd OBJECT IDENTIFIER ::= { component 4 } dasdFailed NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, scsiId, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "a direct access storage device has failed." ::= { dasd 1 } dasdInserted NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, scsiId, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "A direct access storage device has been inserted." ::= { dasd 2 } dasdRemoved NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, scsiId, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "A direct access storage device has been removed." ::= { dasd 3 } memory OBJECT IDENTIFIER ::= { component 5 } memoryFailed NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "Some memory has failed." ::= { memory 1 } componentFan OBJECT IDENTIFIER ::= { component 6 } componentFanFailed NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "A fan has failed." ::= { componentFan 1 } componentFanInserted NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "A fan has been inserted." ::= { componentFan 2 } componentFanPfa NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "The fan component has generated a PFA." ::= { componentFan 3 } componentFanRemoved NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "A fan has been removed." ::= { componentFan 4 } hardwareInformation OBJECT IDENTIFIER ::= { component 7 } hardwareCrashDump OBJECT IDENTIFIER ::= { hardwareInformation 1 } hardwareCrashDumpAborted NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "A hardware crash dump was aborted." ::= { hardwareCrashDump 1 } hardwareCrashDumpCompleted NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "A hardware crash dump has completed." ::= { hardwareCrashDump 2 } hardwareCrashDumpInitiated NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "A hardware crash dump has been initiated." ::= { hardwareCrashDump 3 } ioModule OBJECT IDENTIFIER ::= { component 8 } ioModuleConfiguration NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, ipAddress1, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "An I/O module's configuration has changed." ::= { ioModule 1 } ioModuleFailed NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "An I/O module has failed." ::= { ioModule 2 } ioModuleInserted NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "An I/O module has been inserted." ::= { ioModule 3 } ioModulePost NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "An I/O module has past POST." ::= { ioModule 4 } ioModulePower OBJECT IDENTIFIER ::= { ioModule 5 } ioModulePowerOn NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "An I/O module has been powered on." ::= { ioModulePower 1 } ioModulePowerOff NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "An I/O module has been powered off." ::= { ioModulePower 2 } ioModuleRedundancy NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "An I/O module is a redundancy." ::= { ioModule 6 } ioModuleRemoved NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "An I/O module has been removed." ::= { ioModule 7 } kvm OBJECT IDENTIFIER ::= { component 9 } kvmOwner NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The KVM owner has changed." ::= { kvm 1 } osImage OBJECT IDENTIFIER ::= { component 10 } osImageCrashDump OBJECT IDENTIFIER ::= { osImage 1 } osImageCrashDumpAborted NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The operating system image crash dump was aborted." ::= { osImageCrashDump 1 } osImageCrashDumpCompleted NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The operating system image crash dump has completed." ::= { osImageCrashDump 2 } osImageCrashDumpInitiated NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The operating system image crash dump has been initiated." ::= { osImageCrashDump 3 } componentPfa NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "A component has generated a PFA." ::= { component 11 } powerSubsystem OBJECT IDENTIFIER ::= { component 12 } powerSubsystemLowFuel NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The power subsystem indicates low fuel." ::= { powerSubsystem 1 } powerSubsystemOverCurrent NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The power subsystem indicates over current." ::= { powerSubsystem 2 } powerSubsystemOverPower NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The power subsystem indicates over power." ::= { powerSubsystem 3 } powerSubsystemRedundancy NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The power subsystem indicates a redundancy." ::= { powerSubsystem 4 } powerSupply OBJECT IDENTIFIER ::= { component 13 } powerSupplyFailed NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, reason, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "A power supply has failed." ::= { powerSupply 1 } powerSupplyInserted NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "A power supply has been inserted." ::= { powerSupply 2 } powerSupplyRemoved NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "A power supply has been removed." ::= { powerSupply 3 } server OBJECT IDENTIFIER ::= { component 14 } serverPower OBJECT IDENTIFIER ::= { server 1 } serverPowerOff NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The server has powered off." ::= { serverPower 1 } serverPowerOn NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The server has powered on." ::= { serverPower 2 } serverPowerState NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, newState, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The server's power state has changed." ::= { server 2 } serviceProcessor OBJECT IDENTIFIER ::= { component 15 } serviceProcessorActive NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "A service processor is now active." ::= { serviceProcessor 1 } serviceProcessorConfiguration NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "A service processor configuration has changed." ::= { serviceProcessor 2 } serviceProcessorInserted NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "A service processor has been inserted." ::= { serviceProcessor 3 } serviceProcessorLog NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "A service processor has generated a log." ::= { serviceProcessor 4 } serviceProcessorNetworkStack NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, ipAddress1, ipAddress2, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "A service processor network stack has changed." ::= { serviceProcessor 5 } serviceProcessorRedundancy NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "A service processor detected a redundancy." ::= { serviceProcessor 6 } serviceProcessorRemoteLogin NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "A remove login was made into the service processor." ::= { serviceProcessor 7 } serviceProcessorRemoved NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "A service processor has been removed." ::= { serviceProcessor 8 } serviceProcessorRestart NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "A service processor has been restarted." ::= { serviceProcessor 9 } serviceProcessorTest NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "A service processor test was issued." ::= { serviceProcessor 10 } smpExpansionModule OBJECT IDENTIFIER ::= { component 16 } smpExpansionModuleDisabled NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "An SMP expansion module has been disabled." ::= { smpExpansionModule 1 } usb OBJECT IDENTIFIER ::= { component 17 } usbInserted NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "A USB device has been inserted." ::= { usb 1 } usbOwner NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "A USB device owner has changed." ::= { usb 2 } usbRemoved NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "A USB device has been removed." ::= { usb 3 } vrm OBJECT IDENTIFIER ::= { component 18 } vrmFailed NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber } STATUS current DESCRIPTION "The VRM has failed." ::= { vrm 1 } critical OBJECT IDENTIFIER ::= { mpaFamily 3 } hardDiskDrive NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, universalUniqueId } STATUS current DESCRIPTION "A hard disk drive is in critical state." ::= { critical 1 } multipleFanFailure NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, universalUniqueId } STATUS current DESCRIPTION "Multiple fans have failed." ::= { critical 2 } powerFailure OBJECT IDENTIFIER ::= { critical 3 } powerFailureEpow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, unitNumber, universalUniqueId } STATUS current DESCRIPTION "There was a critical power failure as a result of an EPOW." ::= { powerFailure 1 } powerFailureFailed NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, unitNumber, universalUniqueId } STATUS current DESCRIPTION "There was a critical power failure as a result of something failing." ::= { powerFailure 2 } powerFailureRemoved NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, unitNumber, universalUniqueId } STATUS current DESCRIPTION "There was a critical power failure as a result of something removed." ::= { powerFailure 3 } criticalTamper NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, universalUniqueId } STATUS current DESCRIPTION "Tampering with the system has caused a critical state." ::= { critical 4 } criticalTemperature OBJECT IDENTIFIER ::= { critical 5 } criticalTemperatureAmbient NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "The ambient temperature is in a critical state." ::= { criticalTemperature 1 } criticalTemperaturePci NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "The PCI temperature is in a critical state." ::= { criticalTemperature 2 } criticalTemperaturePlanar NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "The planar temperature is in a critical state." ::= { criticalTemperature 3 } criticalVoltage OBJECT IDENTIFIER ::= { critical 6 } criticalTwelveVolts OBJECT IDENTIFIER ::= { criticalVoltage 1 } criticalTwelveVoltsHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 12V high has been detected." ::= { criticalTwelveVolts 1 } criticalTwelveVoltsLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 12V low has been detected." ::= { criticalTwelveVolts 2 } criticalTwelveVoltsFaultA NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 12V fault A has been detected." ::= { criticalVoltage 2 } criticalTwelveVoltsFaultB NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 12V fault B has been detected." ::= { criticalVoltage 3 } criticalTwelveVoltsFaultC NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 12V fault C has been detected." ::= { criticalVoltage 4 } criticalTwelveVoltsFaultD NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 12V fault D has been detected." ::= { criticalVoltage 5 } criticalOneVolt OBJECT IDENTIFIER ::= { criticalVoltage 6 } criticalOneVoltHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 1V high has been detected." ::= { criticalOneVolt 1 } criticalOneVoltLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 1V low has been detected." ::= { criticalOneVolt 2 } criticalTwoVolts OBJECT IDENTIFIER ::= { criticalVoltage 7 } criticalTwoVoltsHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 2V high has been detected." ::= { criticalTwoVolts 1 } criticalTwoVoltsLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 2V low has been detected." ::= { criticalTwoVolts 2 } criticalThreeVolts OBJECT IDENTIFIER ::= { criticalVoltage 8 } criticalThreeVoltsHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 3V high has been detected." ::= { criticalThreeVolts 1 } criticalThreeVoltsLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 3V low has been detected." ::= { criticalThreeVolts 2 } criticalThreeVoltsPci OBJECT IDENTIFIER ::= { criticalVoltage 9 } criticalThreeVoltsPciHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 3V high has been detected for the PCI." ::= { criticalThreeVoltsPci 1 } criticalThreeVoltsPciLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 3V low has been detected for the PCI." ::= { criticalThreeVoltsPci 2 } criticalThreeVoltsStandby OBJECT IDENTIFIER ::= { criticalVoltage 10 } criticalThreeVoltsStandbyHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 3V standby high has been detected." ::= { criticalThreeVoltsStandby 1 } criticalThreeVoltsStandbyLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 3V standby low has been detected." ::= { criticalThreeVoltsStandby 2 } criticalFiveVolts OBJECT IDENTIFIER ::= { criticalVoltage 11 } criticalFiveVoltsHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 5V high has been detected." ::= { criticalFiveVolts 1 } criticalFiveVoltsLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 5V low has been detected." ::= { criticalFiveVolts 2 } criticalFiveVoltsFault OBJECT IDENTIFIER ::= { criticalVoltage 12 } criticalFiveVoltsFaultHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 5V fault high has been detected." ::= { criticalFiveVoltsFault 1 } criticalFiveVoltsFaultLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 5V fault low has been detected." ::= { criticalFiveVoltsFault 2 } criticalFiveVoltsPci OBJECT IDENTIFIER ::= { criticalVoltage 13 } criticalFiveVoltsPciHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 5V high has been detected for the PCI." ::= { criticalFiveVoltsPci 1 } criticalFiveVoltsPciLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 5V low has been detected for the PCI." ::= { criticalFiveVoltsPci 2 } criticalFiveVoltsStandby OBJECT IDENTIFIER ::= { criticalVoltage 14 } criticalFiveVoltsStandbyHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 5V standby high has been detected." ::= { criticalFiveVoltsStandby 1 } criticalFiveVoltsStandbyLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of 5V standby low has been detected." ::= { criticalFiveVoltsStandby 2 } criticalNTwelveVolts OBJECT IDENTIFIER ::= { criticalVoltage 15 } criticalNTwelveVoltsHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of negative 12V high has been detected." ::= { criticalNTwelveVolts 1 } criticalNTwelveVoltsLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A critical state of negative 12V low has been detected." ::= { criticalNTwelveVolts 2 } voltageRegulatorModuleFailure NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, universalUniqueId } STATUS current DESCRIPTION "The voltage regulator module has failed." ::= { critical 7 } deployment OBJECT IDENTIFIER ::= { mpaFamily 4 } deploymentBoot NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "Deployment has generated a boot event." ::= { deployment 1 } deploymentLoader NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "Deployment has generated a loader event." ::= { deployment 2 } deploymentOs NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "Deployment has generated an operating system event." ::= { deployment 3 } deploymentPost NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "Deployment has generated a POST event." ::= { deployment 4 } environmental OBJECT IDENTIFIER ::= { mpaFamily 5 } environmentalTemperature NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, side, sourceUniversalUniqueId, temperatureSensor, unitNumber } STATUS current DESCRIPTION "The environmental temperature has changed." ::= { environmental 1 } environmentalVoltage NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, componentId, firmwareCode, senderUniversalUniqueId, side, sourceUniversalUniqueId, threshold, voltageSensor } STATUS current DESCRIPTION "The environmental voltage has changed." ::= { environmental 2 } nonCritical OBJECT IDENTIFIER ::= { mpaFamily 6 } nonCriticalFan OBJECT IDENTIFIER ::= { nonCritical 1 } nonCriticalFanRemoved NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, universalUniqueId } STATUS current DESCRIPTION "A fan has been removed." ::= { nonCriticalFan 1 } redundantPower NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, universalUniqueId } STATUS current DESCRIPTION "The system is now running on redundant power." ::= { nonCritical 2 } singleFanFailure NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, unitNumber, universalUniqueId } STATUS current DESCRIPTION "A single fan has failed." ::= { nonCritical 3 } nonCriticalTemperature OBJECT IDENTIFIER ::= { nonCritical 4 } nonCriticalTemperatureAmbient NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "The ambient temperature is in a non critical state." ::= { nonCriticalTemperature 1 } nonCriticalTemperaturePci NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "The PCI temperature is in a non critical state." ::= { nonCriticalTemperature 2 } nonCriticalTemperaturePlanar NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "The planar temperature is in a non critical state." ::= { nonCriticalTemperature 3 } nonCriticalVoltage OBJECT IDENTIFIER ::= { nonCritical 5 } nonCriticalTwelveVolts OBJECT IDENTIFIER ::= { nonCriticalVoltage 1 } nonCriticalTwelveVoltsHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of 12V high has been detected." ::= { nonCriticalTwelveVolts 1 } nonCriticalTwelveVoltsLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of 12V low has been detected." ::= { nonCriticalTwelveVolts 2 } nonCriticalOneVolt OBJECT IDENTIFIER ::= { nonCriticalVoltage 2 } nonCriticalOneVoltHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of 1V high has been detected." ::= { nonCriticalOneVolt 1 } nonCriticalOneVoltLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of 1V low has been detected." ::= { nonCriticalOneVolt 2 } nonCriticalTwoVolts OBJECT IDENTIFIER ::= { nonCriticalVoltage 3 } nonCriticalTwoVoltsHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of 2V high has been detected." ::= { nonCriticalTwoVolts 1 } nonCriticalTwoVoltsLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of 2V low has been detected." ::= { nonCriticalTwoVolts 2 } nonCriticalThreeVolts OBJECT IDENTIFIER ::= { nonCriticalVoltage 4 } nonCriticalThreeVoltsHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of 3V high has been detected." ::= { nonCriticalThreeVolts 1 } nonCriticalThreeVoltsLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of 3V low has been detected." ::= { nonCriticalThreeVolts 2 } nonCriticalThreeVoltsPci OBJECT IDENTIFIER ::= { nonCriticalVoltage 5 } nonCriticalThreeVoltsPciHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of 3V high has been detected for the PCI." ::= { nonCriticalThreeVoltsPci 1 } nonCriticalThreeVoltsPciLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of 3V low has been detected for the PCI." ::= { nonCriticalThreeVoltsPci 2 } nonCriticalThreeVoltsStandby OBJECT IDENTIFIER ::= { nonCriticalVoltage 6 } nonCriticalThreeVoltsStandbyHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of 3V standby high has been detected." ::= { nonCriticalThreeVoltsStandby 1 } nonCriticalThreeVoltsStandbyLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of 3V standby low has been detected." ::= { nonCriticalThreeVoltsStandby 2 } nonCriticalFiveVolts OBJECT IDENTIFIER ::= { nonCriticalVoltage 7 } nonCriticalFiveVoltsHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of 5V high has been detected." ::= { nonCriticalFiveVolts 1 } nonCriticalFiveVoltsLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of 5V low has been detected." ::= { nonCriticalFiveVolts 2 } nonCriticalFiveVoltsPci OBJECT IDENTIFIER ::= { nonCriticalVoltage 8 } nonCriticalFiveVoltsPciHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of 5V high has been detected for the PCI." ::= { nonCriticalFiveVoltsPci 1 } nonCriticalFiveVoltsPciLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of 5V low has been detected for the PCI." ::= { nonCriticalFiveVoltsPci 2 } nonCriticalFiveVoltsStandby OBJECT IDENTIFIER ::= { nonCriticalVoltage 9 } nonCriticalFiveVoltsStandbyHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of 5V standby high has been detected." ::= { nonCriticalFiveVoltsStandby 1 } nonCriticalFiveVoltsStandbyLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of 5V standby low has been detected." ::= { nonCriticalFiveVoltsStandby 2 } nonCriticalNTwelveVolts OBJECT IDENTIFIER ::= { nonCriticalVoltage 10 } nonCriticalNTwelveVoltsHigh NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of negative 12V high has been detected." ::= { nonCriticalNTwelveVolts 1 } nonCriticalNTwelveVoltsLow NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, side, universalUniqueId } STATUS current DESCRIPTION "A non-critical state of negative 12V low has been detected." ::= { nonCriticalNTwelveVolts 2 } platform OBJECT IDENTIFIER ::= { mpaFamily 7 } scalableNode OBJECT IDENTIFIER ::= { platform 1 } scalableNodeMode OBJECT IDENTIFIER ::= { scalableNode 1 } scalableNodeModeNullOrUnknown NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The scalable node is in a null or unknown mode." ::= { scalableNodeMode 1 } scalableNodeModePrimary NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The scalable node is in primary mode." ::= { scalableNodeMode 2 } scalableNodeModeSecondary NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The scalable node is in secondary mode." ::= { scalableNodeMode 3 } scalableNodeModeStandalone NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The scalable node is now in standalone mode." ::= { scalableNodeMode 4 } scalableNodeStandalone OBJECT IDENTIFIER ::= { scalableNode 2 } standaloneMode OBJECT IDENTIFIER ::= { scalableNodeStandalone 1 } primary NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The scalable node is now in standalone primary mode." ::= { standaloneMode 1 } reset OBJECT IDENTIFIER ::= { standaloneMode 2 } resetPrimary NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The scalable node is now in standalone primary reset mode." ::= { reset 1 } resetSecondary NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The scalable node is now in standalone primary secondary mode." ::= { reset 2 } secondary NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The scalable node is now in standalone secondary mode." ::= { standaloneMode 3 } scalablePartition OBJECT IDENTIFIER ::= { platform 2 } scalablePartitionAlert NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, alertCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The scalabel partition has generated an alert." ::= { scalablePartition 1 } scalablePartitionState OBJECT IDENTIFIER ::= { scalablePartition 2 } scalablePartitionNullOrUnknown NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The scalable partition state is 'null or unknown'." ::= { scalablePartitionState 1 } scalablePartitionPoweredOff NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The scalable partition state is 'powered off'." ::= { scalablePartitionState 2 } scalablePartitionPoweringOn NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The scalable partition state is 'powering on'." ::= { scalablePartitionState 3 } scalablePartitionResetting NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The scalable partition state is 'resetting'." ::= { scalablePartitionState 4 } scalablePartitionShuttingDown NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The scalable partition state is 'shutting down'." ::= { scalablePartitionState 5 } system OBJECT IDENTIFIER ::= { mpaFamily 8 } bootFailure NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, universalUniqueId } STATUS current DESCRIPTION "The system indicated a boot failure." ::= { system 1 } fuelGauge OBJECT IDENTIFIER ::= { system 2 } fuelGaugeLowFuel NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, universalUniqueId } STATUS current DESCRIPTION "The fuel gauge indicates low fuel." ::= { fuelGauge 1 } fuelGaugeNotRedundant NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, universalUniqueId } STATUS current DESCRIPTION "The fuel gauge indicates not redundant." ::= { fuelGauge 2 } fuelGaugeOverCurrent NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, universalUniqueId } STATUS current DESCRIPTION "The fuel gauge indicates over current." ::= { fuelGauge 3 } systemLoaderTimeout NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, universalUniqueId } STATUS current DESCRIPTION "The system loader has timed out." ::= { system 3 } systemOsTimeout NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, universalUniqueId } STATUS current DESCRIPTION "The operating system has timed out." ::= { system 4 } systemPfa OBJECT IDENTIFIER ::= { system 5 } fanSystemPfa NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, unitNumber, universalUniqueId } STATUS current DESCRIPTION "The fan system has generated a PFA." ::= { systemPfa 1 } systemPostTimeout NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, universalUniqueId } STATUS current DESCRIPTION "The POST has timed out." ::= { system 6 } systemPowerOff NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, universalUniqueId } STATUS current DESCRIPTION "The sytsem has powered off." ::= { system 7 } systemPowerOn NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, universalUniqueId } STATUS current DESCRIPTION "The sytsem has powered on." ::= { system 8 } systemRedundantPower NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, universalUniqueId } STATUS current DESCRIPTION "The system is running on redundant power." ::= { system 9 } systemTamper NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, universalUniqueId } STATUS current DESCRIPTION "The system has been tampered with." ::= { system 10 } unknown NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, firmwareCode, senderUniversalUniqueId, sourceUniversalUniqueId } STATUS current DESCRIPTION "The system is in an unknown state." ::= { mpaFamily 9 } -- -- PET/ASF traps -- petFamily OBJECT IDENTIFIER ::= { directorTraps 5 } petFamilyEventDetails OBJECT IDENTIFIER ::= { petFamily 1 } allVariableBindings OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "All of the variable bindings for this PET trap." ::= { petFamilyEventDetails 1 } entity OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The entity of this PET event." ::= { petFamilyEventDetails 2 } entityInstance OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The entity instance of this PET event." ::= { petFamilyEventDetails 3 } petEventData OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The event data of this PET event." ::= { petFamilyEventDetails 4 } petEventSeverity OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of this PET event." ::= { petFamilyEventDetails 5 } petEventSourceType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The source type of this PET event." ::= { petFamilyEventDetails 6 } petEventType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the PET event." ::= { petFamilyEventDetails 7 } guid OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The GUID for this PET event." ::= { petFamilyEventDetails 8 } languageCode OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The language code for this PET event." ::= { petFamilyEventDetails 9 } localTimeStamp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The local time stamp of this PET event." ::= { petFamilyEventDetails 10 } manufacturerId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The manufacturer ID for the source of the PET event." ::= { petFamilyEventDetails 11 } oemCustomField OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The value for the OEM customer field of this PET event." ::= { petFamilyEventDetails 12 } offset OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The offset for this PET event." ::= { petFamilyEventDetails 13 } sensorDevice OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The sensor device for this PET event." ::= { petFamilyEventDetails 14 } sensorNumber OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The sensor number for this PET event." ::= { petFamilyEventDetails 15 } sensorType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The sensor type for this PET event." ::= { petFamilyEventDetails 16 } sequenceId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The sequence ID for this PET event." ::= { petFamilyEventDetails 17 } systemId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The system ID for this PET event." ::= { petFamilyEventDetails 18 } trapSourceType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The trap source type for this PET event." ::= { petFamilyEventDetails 19 } utcOffset OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The UTC offset for this PET event." ::= { petFamilyEventDetails 20 } petEnvironmental OBJECT IDENTIFIER ::= { petFamily 2 } petEnvironmentalSensor OBJECT IDENTIFIER ::= { petEnvironmental 1 } sensorCaseIntrusion NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType, petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset, sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset } STATUS current DESCRIPTION "A sensor has detected a case intrusion." ::= { petEnvironmentalSensor 1 } sensorCurrent NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType, petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset, sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset } STATUS current DESCRIPTION "A sensor has detected a current change." ::= { petEnvironmentalSensor 2 } sensorFan NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType, petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset, sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset } STATUS current DESCRIPTION "A sensor has detected a fan change." ::= { petEnvironmentalSensor 3 } sensorPowerSupply NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType, petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset, sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset } STATUS current DESCRIPTION "A sensor has detected a power supply change." ::= { petEnvironmentalSensor 4 } sensorTemperature NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType, petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset, sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset } STATUS current DESCRIPTION "A sensor has detected a temperature change." ::= { petEnvironmentalSensor 5 } sensorVoltage NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType, petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset, sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset } STATUS current DESCRIPTION "A sensor has detected a voltage change." ::= { petEnvironmentalSensor 6 } firmware OBJECT IDENTIFIER ::= { petFamily 3 } bios OBJECT IDENTIFIER ::= { firmware 1 } progress NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType, petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset, sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset } STATUS current DESCRIPTION "The progress of the BIOS has changed." ::= { bios 1 } hardware OBJECT IDENTIFIER ::= { petFamily 4 } cableInterconnect NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType, petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset, sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset } STATUS current DESCRIPTION "The cable/interconnect hardware has generated an event." ::= { hardware 1 } drivebay NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType, petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset, sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset } STATUS current DESCRIPTION "The monitor drivebay hardware has generated an event." ::= { hardware 2 } moduleBoard NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType, petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset, sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset } STATUS current DESCRIPTION "The monitor module/board hardware has generated an event." ::= { hardware 3 } monitorAsicIc NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType, petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset, sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset } STATUS current DESCRIPTION "The monitor ASIC/IC hardware has generated an event." ::= { hardware 4 } network NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType, petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset, sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset } STATUS current DESCRIPTION "The network hardware has generated an event." ::= { hardware 5 } watchdog1 NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType, petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset, sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset } STATUS current DESCRIPTION "The hardware has generated a watchdog 1 event." ::= { hardware 6 } watchdog2 NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType, petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset, sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset } STATUS current DESCRIPTION "The hardware has generated a watchdog 2 event." ::= { hardware 7 } petFamilySystem OBJECT IDENTIFIER ::= { petFamily 5 } petFamilySystemOs OBJECT IDENTIFIER ::= { petFamilySystem 1 } petFamilySystemOsBoot NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType, petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset, sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset } STATUS current DESCRIPTION "The operating system on the host has booted." ::= { petFamilySystemOs 1 } petFamilySystemOsOperation OBJECT IDENTIFIER ::= { petFamilySystemOs 2 } heartbeat NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType, petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset, sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset } STATUS current DESCRIPTION "The operating system has generated a heartbeat event." ::= { petFamilySystemOsOperation 1 } -- -- Storage traps -- storageFamily OBJECT IDENTIFIER ::= { directorTraps 6 } serveRaidController OBJECT IDENTIFIER ::= { storageFamily 1 } physicalDrive OBJECT IDENTIFIER ::= { serveRaidController 1 } vendorUnsupported NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory } STATUS current DESCRIPTION "The vendor for this physical drive is unsupported." ::= { physicalDrive 1 } state OBJECT IDENTIFIER ::= { serveRaidController 2 } notFound NOTIFICATION-TYPE OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory } STATUS current DESCRIPTION "No controllers were found in this system." ::= { state 1 } -- -- The trap description objects -- trapType OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the event." ::= { description 1 } trapSeverity OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the event." ::= { description 2 } trapSenderName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The system name from which the event was sent." ::= { description 3 } trapManagedObjectName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The system name for which the event was generated." ::= { description 4 } trapText OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Text associated with the event." ::= { description 5 } trapCategory OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The category of the event." ::= { description 6 } -- -- Trap detail types -- -- NOTE: -- -- When viewing a trap holding an event detail type, the number following these -- OIDs refer to different values of this type. They increment according to -- each trap, ergo, you should never see a { char 2 } without a { char 1 }. -- char OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Eight bit unsigned event detail." ::= { details 1 } short OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Sixteen bit signed event detail." ::= { details 2 } int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Thirty-two bit signed event detail." ::= { details 3 } long OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Sixty-four bit signed event detail." ::= { details 4 } boolean OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Thirty-two bit unsigned event detail." ::= { details 5 } float OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Thirty-two bit decimal pointed event detail." ::= { details 6 } double OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Sixty-four bit decimal pointed event detail." ::= { details 7 } octet OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A string of bytes holding an event detail." ::= { details 8 } string OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "A string of unicode chars (normal text) holding an event detail." ::= { details 9 } dateTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Date and time since 1/1970 as an event detail." ::= { details 10 } uniChar OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A unicode char holding an event detail." ::= { details 11 } byte OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "One byte holding an event detail." ::= { details 12 } directorTrapsConformance OBJECT IDENTIFIER ::= { directorTraps 100 } directorTrapsGroups OBJECT IDENTIFIER ::= { directorTrapsConformance 1 } directorTrapsCompliances OBJECT IDENTIFIER ::= { directorTrapsConformance 2 } directorTrapsCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for this module." MODULE -- this module MANDATORY-GROUPS { directorTrapsGroup, directorNotificationsGroup } ::= { directorTrapsCompliances 1 } directorTrapsGroup OBJECT-GROUP OBJECTS { trapType, trapSeverity, trapSenderName, trapManagedObjectName, trapText, trapCategory, char, short, int, long, boolean, float, octet, double, string, dateTime, uniChar, byte, actualValue, duration, monitorResource, thresholdName, thresholdValue, userID, address, userName, userDescription, userLocale, category, categoryString, computerName, data, eventLogCode, eventLogIdentifier, eventLogType, insertionStrings, logFile, message, recordNumber, sourceName, type, user, acceptPause, acceptStop, caption, checkPoint, creationClassName, serviceDescription, desktopInteract, displayName, errorControl, exitCode, name, pathName, processId, serviceSpecificExitCode, serviceType, startMode, startName, started, serviceState, status, systemCreationClassName, systemName, tagId, waitHint, hive, rootPath, securityDescriptor, timeCreated, alertCode, busId, componentId, firmwareCode, ipAddress1, ipAddress2, issue, powerDomain, reason, scsiId, side, newState, temperatureSensor, threshold, universalUniqueId, senderUniversalUniqueId, sourceUniversalUniqueId, unitNumber, voltageSensor, allVariableBindings, entity, entityInstance, petEventData, petEventSeverity, petEventSourceType, petEventType, guid, languageCode, localTimeStamp, manufacturerId, oemCustomField, offset, sensorDevice, sensorNumber, sensorType, sequenceId, systemId, trapSourceType, utcOffset } STATUS current DESCRIPTION "The objects group for objects defined in this module." ::= { directorTrapsGroups 1 } directorNotificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { generalEvent, online, offline, create, change, destroy, processMonitor, cpuUtilization, processCount, driveSpaceUsed, driveSpaceUsedPercent, driveSpaceRemaining, driveWorkload, lockedMemory, memoryUsage, totalPrivilegedTimePercent, fileReadOperationsPerSec, udpPacketsSentPerSec, udpPacketsReceivedPerSec, ipPacketsSentPerSec, ipPacketsReceivedPerSec, ipErrorPacketsReceivedPerSec, tcpConnections, action, badPassword, badUserID, disabledUserID, downlevelConsole, expiredPassword, tooManyActiveIDs, tooManyActiveLogons, uplevelConsole, logoff, logon, applicationLog, securityLog, systemLog, startedService, stoppedService, softwareTreeChanged, systemTreeChanged, codEnabled, bladeServerCommunication, bladeServerInserted, bladeServerRemoved, busCommunication, chassisConfiguration, chassisFailed, dasdFailed, dasdInserted, dasdRemoved, memoryFailed, componentFanFailed, componentFanInserted, componentFanPfa, componentFanRemoved, hardwareCrashDumpAborted, hardwareCrashDumpCompleted, hardwareCrashDumpInitiated, ioModuleConfiguration, ioModuleFailed, ioModuleInserted, ioModulePost, ioModulePowerOn, ioModulePowerOff, ioModuleRedundancy, ioModuleRemoved, kvmOwner, osImageCrashDumpAborted, osImageCrashDumpCompleted, osImageCrashDumpInitiated, componentPfa, powerSubsystemLowFuel, powerSubsystemOverCurrent, powerSubsystemOverPower, powerSubsystemRedundancy, powerSupplyFailed, powerSupplyInserted, powerSupplyRemoved, serverPowerOff, serverPowerOn, serverPowerState, serviceProcessorActive, serviceProcessorConfiguration, serviceProcessorInserted, serviceProcessorLog, serviceProcessorNetworkStack, serviceProcessorRedundancy, serviceProcessorRemoteLogin, serviceProcessorRemoved, serviceProcessorRestart, serviceProcessorTest, smpExpansionModuleDisabled, usbInserted, usbOwner, usbRemoved, vrmFailed, hardDiskDrive, multipleFanFailure, powerFailureEpow, powerFailureFailed, powerFailureRemoved, criticalTamper, criticalTemperatureAmbient, criticalTemperaturePci, criticalTemperaturePlanar, criticalTwelveVoltsHigh, criticalTwelveVoltsLow, criticalTwelveVoltsFaultA, criticalTwelveVoltsFaultB, criticalTwelveVoltsFaultC, criticalTwelveVoltsFaultD, criticalOneVoltHigh, criticalOneVoltLow, criticalTwoVoltsHigh, criticalTwoVoltsLow, criticalThreeVoltsHigh, criticalThreeVoltsLow, criticalThreeVoltsPciHigh, criticalThreeVoltsPciLow, criticalThreeVoltsStandbyHigh, criticalThreeVoltsStandbyLow, criticalFiveVoltsHigh, criticalFiveVoltsLow, criticalFiveVoltsFaultHigh, criticalFiveVoltsFaultLow, criticalFiveVoltsPciHigh, criticalFiveVoltsPciLow, criticalFiveVoltsStandbyHigh, criticalFiveVoltsStandbyLow, criticalNTwelveVoltsHigh, criticalNTwelveVoltsLow, voltageRegulatorModuleFailure, deploymentBoot, deploymentLoader, deploymentOs, deploymentPost, environmentalTemperature, environmentalVoltage, nonCriticalFanRemoved, redundantPower, singleFanFailure, nonCriticalTemperatureAmbient, nonCriticalTemperaturePci, nonCriticalTemperaturePlanar, nonCriticalTwelveVoltsHigh, nonCriticalTwelveVoltsLow, nonCriticalOneVoltHigh, nonCriticalOneVoltLow, nonCriticalTwoVoltsHigh, nonCriticalTwoVoltsLow, nonCriticalThreeVoltsHigh, nonCriticalThreeVoltsLow, nonCriticalThreeVoltsPciHigh, nonCriticalThreeVoltsPciLow, nonCriticalThreeVoltsStandbyHigh, nonCriticalThreeVoltsStandbyLow, nonCriticalFiveVoltsHigh, nonCriticalFiveVoltsLow, nonCriticalFiveVoltsPciHigh, nonCriticalFiveVoltsPciLow, nonCriticalFiveVoltsStandbyHigh, nonCriticalFiveVoltsStandbyLow, nonCriticalNTwelveVoltsHigh, nonCriticalNTwelveVoltsLow, scalableNodeModeNullOrUnknown, scalableNodeModePrimary, scalableNodeModeSecondary, scalableNodeModeStandalone, primary, resetPrimary, resetSecondary, secondary, scalablePartitionAlert, scalablePartitionNullOrUnknown, scalablePartitionPoweredOff, scalablePartitionPoweringOn, scalablePartitionResetting, scalablePartitionShuttingDown, bootFailure, fuelGaugeLowFuel, fuelGaugeNotRedundant, fuelGaugeOverCurrent, systemLoaderTimeout, systemOsTimeout, fanSystemPfa, systemPostTimeout, systemPowerOff, systemPowerOn, systemRedundantPower, systemTamper, unknown, sensorCaseIntrusion, sensorCurrent, sensorFan, sensorPowerSupply, sensorTemperature, sensorVoltage, progress, cableInterconnect, drivebay, moduleBoard, monitorAsicIc, network, watchdog1, watchdog2, petFamilySystemOsBoot, heartbeat, vendorUnsupported, notFound } STATUS current DESCRIPTION "The notification group for notifications defined in this module." ::= { directorTrapsGroups 2 } END