IBM3172-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Counter32, Integer32, enterprises FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC -- RFC1903 MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF ifIndex FROM IF-MIB; ibm3172MIB MODULE-IDENTITY LAST-UPDATED "9704070000Z" ORGANIZATION "OS/390 TCP/IP OpenEdition Development" CONTACT-INFO " Kenneth White Postal: International Business Machines Corporation P.O. Box 12195 Dept. G80/Bldg. 503 Research Triangle Park, NC 27709 USA Tel: +1 919 254 0102 Fax: +1 919 254 4027 E-mail: kennethw@vnet.ibm.com" DESCRIPTION "The MIB module for managing an IBM 3172 Device that has is running ICP." ::= { ibm3172 8 } ibm OBJECT IDENTIFIER ::= { enterprises 2 } ibmProd OBJECT IDENTIFIER ::= { ibm 6 } ibm3172 OBJECT IDENTIFIER ::= { ibmProd 1} -- ifIndex ::= INTEGER -- -- IBM 3172 System Table -- ibm3172SystemTable OBJECT-TYPE SYNTAX SEQUENCE OF Ibm3172SystemTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Descriptive information about units of 3172s." ::= { ibm3172 1 } ibm3172SystemTableEntry OBJECT-TYPE SYNTAX Ibm3172SystemTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Descriptive information about a 3172." INDEX { ifIndex } ::= { ibm3172SystemTable 1 } Ibm3172SystemTableEntry ::= SEQUENCE { ibm3172Descr DisplayString, ibm3172Contact DisplayString, ibm3172Location DisplayString, ibm3172ifNumber Integer32 } ibm3172Descr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..253)) MAX-ACCESS read-only STATUS current DESCRIPTION "Text Description of the 3172. Contains information on the hardware and software of the 3172. The format of the ibm3172Descr variable is : ttttxMODELxmmm,xSERIALxNUMBERxsssssssss,xiiiiiiiiiix 111111,xPROGRAMxNUMBERxpppppp where : x represents a blank character upper case letters are hardcoded characters , represents a comma the remaining lower case letters represent variable data as follows: t - machine type m - model number s - serial number i - software program name l - software level numbers p - software program product number. An example of the information sent with this attribute would be : '3172 MODEL 001, SERIAL NUMBER 000001234, 3172 Interconnect Ctlr Program 020100, 5601433'" ::= { ibm3172SystemTableEntry 1 } ibm3172Contact OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The textual identification of the contact person for this 3172, together with information on how to contact this person. This information is provided by the 3172 Operator Facility." ::= { ibm3172SystemTableEntry 2 } ibm3172Location OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The physical location of this node. This information is provided by the 3172 Operator Facility." ::= { ibm3172SystemTableEntry 3 } ibm3172ifNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of interfaces (regardless of their current state) on which this 3172 can send data." ::= { ibm3172SystemTableEntry 4 } -- -- IBM 3172 Trap Table -- ibm3172ifTrapTable OBJECT-TYPE SYNTAX SEQUENCE OF Ibm3172ifTrapTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of objects at the interface level pertaining to the trap function." ::= { ibm3172 2 } ibm3172ifTrapTableEntry OBJECT-TYPE SYNTAX Ibm3172ifTrapTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Objects at the interface level pertaining to the trap function." INDEX { ifIndex } ::= { ibm3172ifTrapTable 1} Ibm3172ifTrapTableEntry ::= SEQUENCE { ibm3172ifTrapEnable INTEGER } ibm3172ifTrapEnable OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Flag to indicate whether the 3172 should send traps for this interface to the SNMP proxy agent. '0' indicates the trap function of the 3172 is disabled, '1' indicates that it is enabled." ::= { ibm3172ifTrapTableEntry 1 } -- -- IBM 3172 Channel Counters -- ibm3172ifChanCountersTable OBJECT-TYPE SYNTAX SEQUENCE OF Ibm3172ifChanCountersTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of objects at the subnetwork layer and below pertaining to a particular subchannel of the 3172." ::= { ibm3172 3 } ibm3172ifChanCountersTableEntry OBJECT-TYPE SYNTAX Ibm3172ifChanCountersTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Objects at the subnetwork layer and below pertaining to a particular subchannel of the 3172." INDEX { ifIndex } ::= { ibm3172ifChanCountersTable 1 } Ibm3172ifChanCountersTableEntry ::= SEQUENCE { ibm3172ifInChanOctets Counter32, ibm3172ifOutChanOctets Counter32, ibm3172ifInChanBlocks Counter32, ibm3172ifOutChanBlocks Counter32 } ibm3172ifInChanOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of inbound octets which were transmitted to the host by the 3172, including all headers." ::= { ibm3172ifChanCountersTableEntry 1 } ibm3172ifOutChanOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of outbound octets which were received from the host by the 3172, including all headers." ::= { ibm3172ifChanCountersTableEntry 2 } ibm3172ifInChanBlocks OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of inbound blocks which were transmitted to the host by the 3172." ::= { ibm3172ifChanCountersTableEntry 3 } ibm3172ifOutChanBlocks OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of outbound blocks which were received from the host by the 3172." ::= { ibm3172ifChanCountersTableEntry 4 } -- -- LAN Counters Table -- ibm3172ifLANCountersTable OBJECT-TYPE SYNTAX SEQUENCE OF Ibm3172ifLANCountersTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of objects at the subnetwork layer and below pertaining to a particular LAN of the 3172." ::= { ibm3172 4 } ibm3172ifLANCountersTableEntry OBJECT-TYPE SYNTAX Ibm3172ifLANCountersTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Objects at the subnetwork layer and below pertaining to a particular LAN of the 3172." INDEX { ifIndex } ::= { ibm3172ifLANCountersTable 1 } Ibm3172ifLANCountersTableEntry ::= SEQUENCE { ibm3172ifInLANOctets Counter32, ibm3172ifOutLANOctets Counter32, ibm3172ifInLANFrames Counter32, ibm3172ifOutLANFrames Counter32, ibm3172ifInLANErrors Counter32, ibm3172ifOutLANErrors Counter32, ibm3172ifInLANDiscards Counter32, ibm3172ifOutLANDiscards Counter32 } ibm3172ifInLANOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of inbound octets which were received from the LAN by the 3172, including all headers." ::= { ibm3172ifLANCountersTableEntry 1 } ibm3172ifOutLANOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of outbound octets which were transmitted to the LAN by the 3172, including all headers." ::= { ibm3172ifLANCountersTableEntry 2 } ibm3172ifInLANFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of inbound frames which were received from the LAN by the 3172." ::= { ibm3172ifLANCountersTableEntry 3 } ibm3172ifOutLANFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of outbound frames which were transmitted to the LAN by the 3172." ::= { ibm3172ifLANCountersTableEntry 4 } ibm3172ifInLANErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of inbound frames received from the LAN by the 3172 that contained errors preventing them from being deliverable to a higher layer protocol. This variable, when combined with ibm3172ifInBlkErrors, reflects the total number of inbound frames not forwarded from the LAN to the host because of errors." ::= { ibm3172ifLANCountersTableEntry 5 } ibm3172ifOutLANErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of outbound frames that could not be transmitted to the LAN because of transmission failures. This variable, when combined with ibm3172ifOutDblkErrors, reflects the total number of outbound frames not transmitted to the LAN because of transmission errors." ::= { ibm3172ifLANCountersTableEntry 6 } ibm3172ifInLANDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of inbound frames received from the LAN that were discarded by the 3172, even though no errors had been detected to prevent their being deliverable to a higher layer protocol. One possible reason for discarding such a frame could be because of insufficient buffer space. This variable, when combined with ibm3172ifInBlkDiscards, reflects the total number of inbound frames not forwarded from the LAN when no error was detected." ::= { ibm3172ifLANCountersTableEntry 7 } ibm3172ifOutLANDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of outbound frames that are discarded." ::= { ibm3172ifLANCountersTableEntry 8 } -- -- IBM 3172 Interfaces Blocker task Table -- ibm3172ifBlkCountersTable OBJECT-TYPE SYNTAX SEQUENCE OF Ibm3172ifBlkCountersTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of objects at the Subnetwork layer and below pertaining to a particular Blocker Task of the 3172." ::= { ibm3172 5 } ibm3172ifBlkCountersTableEntry OBJECT-TYPE SYNTAX Ibm3172ifBlkCountersTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Objects at the Subnetwork layer and below pertaining to a particular Blocker Task of the 3172." INDEX { ifIndex } ::= { ibm3172ifBlkCountersTable 1 } Ibm3172ifBlkCountersTableEntry ::= SEQUENCE { ibm3172ifBlkRcvOctets Counter32, ibm3172ifBlkXmitOctets Counter32, ibm3172ifBlkRcvFrames Counter32, ibm3172ifBlkXmitBlocks Counter32, ibm3172ifInBlkErrors Counter32, ibm3172ifInBlkDiscards Counter32 } ibm3172ifBlkRcvOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of inbound octets which were received by the Blocker from the LAN, including all headers." ::= { ibm3172ifBlkCountersTableEntry 1 } ibm3172ifBlkXmitOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of inbound octets which were transmitted to the channel adapter by the Blocker, including all headers." ::= { ibm3172ifBlkCountersTableEntry 2 } ibm3172ifBlkRcvFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of inbound frames which were received from the LAN adapter by the Blocker Task." ::= { ibm3172ifBlkCountersTableEntry 3 } ibm3172ifBlkXmitBlocks OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of inbound blocks which were transmitted to the channel adapter by the blocker task." ::= { ibm3172ifBlkCountersTableEntry 4 } ibm3172ifInBlkErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of inbound frames transmitted by the LAN adapter to the Blocker Task which contained errors preventing them from being deliverable to a higher layer protocol. This variable, when combined with ibm3172ifInLANErrors, reflects the total number of inbound frames discarded by the 3172 because of errors." ::= { ibm3172ifBlkCountersTableEntry 5 } ibm3172ifInBlkDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of inbound frames transmitted by the LAN adapter to the Blocker Task which were discarded by the 3172, even though no errors had been detected to prevent their being deliverable to a higher layer protocol. One possible reason for discarding such a frame could be because of insufficient buffer space. This variable, when combined with ibm3172ifInLANDiscards, reflects the total number of inbound frames discarded by the 3172 when no error was detected." ::= { ibm3172ifBlkCountersTableEntry 6 } -- -- IBM 3172 Deblocker task Table -- ibm3172ifDblkCountersTable OBJECT-TYPE SYNTAX SEQUENCE OF Ibm3172ifDblkCountersTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of objects at the subnetwork layer and below pertaining to a particular Deblocker Task of the 3172." ::= { ibm3172 6 } ibm3172ifDblkCountersTableEntry OBJECT-TYPE SYNTAX Ibm3172ifDblkCountersTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Objects at the subnetwork layer and below pertaining to a particular Deblocker Task of the 3172." INDEX { ifIndex } ::= { ibm3172ifDblkCountersTable 1} Ibm3172ifDblkCountersTableEntry ::= SEQUENCE { ibm3172ifDblkRcvOctets Counter32, ibm3172ifDblkXmitOctets Counter32, ibm3172ifDblkRcvBlocks Counter32, ibm3172ifDblkXmitFrames Counter32, ibm3172ifOutDblkErrors Counter32, ibm3172ifOutDblkDiscards Counter32 } ibm3172ifDblkRcvOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of outbound octets which were received by the Deblocker from the channel adapter, including all headers." ::= { ibm3172ifDblkCountersTableEntry 1 } ibm3172ifDblkXmitOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of outbound octets which were transmitted to the LAN adapter by the Deblocker, including all headers." ::= { ibm3172ifDblkCountersTableEntry 2 } ibm3172ifDblkRcvBlocks OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of outbound blocks which were received from the channel adapter by the deblocker task." ::= { ibm3172ifDblkCountersTableEntry 3 } ibm3172ifDblkXmitFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of outbound frames which were transmitted to the LAN adapter by the Deblocker Task." ::= { ibm3172ifDblkCountersTableEntry 4 } ibm3172ifOutDblkErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of outbound frames transmitted by the channel adapter to the Deblocker Task which contained errors preventing them from being deliverable to a higher layer protocol. This variable, when combined with ibm3172ifOutLANErrors, reflects the total number of outbound frames discarded by the 3172 because of errors." ::= { ibm3172ifDblkCountersTableEntry 5 } ibm3172ifOutDblkDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of outbound frames transmitted by the channel adapter to the Deblocker Task which were discarded by the 3172, even though no errors had been detected to prevent their being deliverable to a higher layer protocol . One possible reason for discarding such a frame could be because of insufficient buffer space. This variable reflects the total number of outbound frames discarded by the 3172 when no error was detected." ::= { ibm3172ifDblkCountersTableEntry 6 } -- -- IBM 3172 device Table -- ibm3172ifDeviceTable OBJECT-TYPE SYNTAX SEQUENCE OF Ibm3172ifDeviceTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { ibm3172 7 } ibm3172ifDeviceTableEntry OBJECT-TYPE SYNTAX Ibm3172ifDeviceTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { ifIndex } ::= { ibm3172ifDeviceTable 1} Ibm3172ifDeviceTableEntry ::= SEQUENCE { ibm3172ifDeviceNumber Integer32 } ibm3172ifDeviceNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The instance number, used to reference the ibm3172SystemTable, for the device associated with this interface." ::= { ibm3172ifDeviceTableEntry 1 } -- conformance information ibm3172MIBConformance OBJECT IDENTIFIER ::= { ibm3172MIB 2 } ibm3172MIBCompliances OBJECT IDENTIFIER ::= { ibm3172MIBConformance 1 } ibm3172MIBGroups OBJECT IDENTIFIER ::= { ibm3172MIBConformance 2 } -- compliance statements ibm3172MIBCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMPv2 entities which implement the IBM3172 MIB." MODULE -- this module MANDATORY-GROUPS { ibm3172Group } ::= { ibm3172MIBCompliances 1 } -- units of conformance ibm3172Group OBJECT-GROUP OBJECTS { ibm3172Descr, ibm3172Contact, ibm3172Location, ibm3172ifNumber, ibm3172ifTrapEnable, ibm3172ifInChanOctets, ibm3172ifOutChanOctets, ibm3172ifInChanBlocks, ibm3172ifOutChanBlocks, ibm3172ifInLANOctets, ibm3172ifOutLANOctets, ibm3172ifInLANFrames, ibm3172ifOutLANFrames, ibm3172ifInLANErrors, ibm3172ifOutLANErrors, ibm3172ifInLANDiscards, ibm3172ifOutLANDiscards, ibm3172ifBlkRcvOctets, ibm3172ifBlkXmitOctets, ibm3172ifBlkRcvFrames, ibm3172ifBlkXmitBlocks, ibm3172ifInBlkErrors, ibm3172ifInBlkDiscards, ibm3172ifDblkRcvOctets, ibm3172ifDblkXmitOctets, ibm3172ifDblkRcvBlocks, ibm3172ifDblkXmitFrames, ibm3172ifOutDblkErrors, ibm3172ifOutDblkDiscards, ibm3172ifDeviceNumber } STATUS current DESCRIPTION "The ibm3172 group of objects providing for basic management of of an IBM 3172 device running ICP." ::= { ibm3172MIBGroups 1 } END