-- *************************************************************************** -- *************************************************************************** -- -- File : immalert.mib -- Description : Integrated Management Module mib for SNMP alerts -- By : IBM -- Version : 2.6 -- Date : July 26, 2011 -- -- -- Copyright (c) 2011 IBM All Rights Reserved. -- -- -- Contains MIB description for: -- This MIB is used by the IMM to generate traps -- for Alert conditions detected by the management firmware. -- *************************************************************************** -- *************************************************************************** -- *************************************************************************** -- Revisions: -- 07/28/2010 Version 2.0 -- Updated version info for imm2.mib and added portParity and portStopBits since these are supported in IMM2 hardware. -- -- 09/13/2010 Version 2.1 -- added some Trap Types. Removed a couple of Trap Types. Changed some Trap Type names for consistency. -- -- 10/20/2010 Version 2.2 -- add additional OIDs required to be sent with each SNMP Trap. -- -- 02/24/2011 Version 2.3 -- change netfinitySupportProcessor to supportProcessor to be consistent with naming of "ibmProd 158" in other alert MIBs -- -- 03/17/2011 Version 2.4 -- fix spelling of imm2alertMIB -- -- 07/07/2011 Version 2.5 -- changes to make mib compatible with IMM1 -- -- 07/26/2011 Version 2.6 -- correction to "Alert Severity Value", range 0..65535 -- *************************************************************************** IMMALERT-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 enterprises, Counter, TimeTicks, IpAddress FROM RFC1155-SMI mib-2, DisplayString FROM RFC1213-MIB; -- MIB for IMM Alerts starts here ibm OBJECT IDENTIFIER ::= { enterprises 2 } -- IBM products group ibmProd OBJECT IDENTIFIER ::= { ibm 6 } -- IBM Netfinity SP supportProcessor OBJECT IDENTIFIER ::= { ibmProd 158 } -- IBM IMM Alert immalertMIB OBJECT IDENTIFIER ::= { supportProcessor 5 } -- the nfspalt generic trap generator group immtrapg OBJECT IDENTIFIER ::= { immalertMIB 1 } altDateTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Timestamp of Local Date and Time when alert was generated" ::= { immtrapg 1 } altSpTxtId OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "SP System Identification - Text Identification" ::= { immtrapg 3 } altSysUuid OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Host System UUID(Universal Unique ID)" ::= { immtrapg 5 } altSysSern OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Host System Serial Number" ::= { immtrapg 6 } altPriority OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Alert Severity Value - Critical Alert(0) - Non-Critical Alert(2) - System Alert(4) - Recovery(8)" ::= { immtrapg 8 } altMsgText OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Alert Message Text" ::= { immtrapg 9 } altMsgID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Alert Message ID" ::= { immtrapg 10 } altMsgIDPrefix OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Alert Message ID" ::= { immtrapg 11 } altHostContact OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Host Contact" ::= { immtrapg 12 } altHostLocation OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Host Location" ::= { immtrapg 13 } altHostRoomID OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Host Location - Room ID" ::= { immtrapg 14 } altHostRackID OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Host Location - Rack ID" ::= { immtrapg 15 } altHostLowestUpos OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Host Location - Lowest U-position" ::= { immtrapg 16 } altHostBladeBay OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Host Location - BladeBay" ::= { immtrapg 17 } altEventID OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Event Identifier" ::= { immtrapg 18 } altServiceable OBJECT-TYPE SYNTAX INTEGER { notServiceable(0), serviceableByIBM(1), serviceableByCustomer(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Serviceability information." ::= { immtrapg 19 } altTest OBJECT-TYPE SYNTAX INTEGER { false(0), true(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This event generated for test purposes." ::= { immtrapg 20 } altFailingFRUs OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Ordered list of Failing FRU Numbers, separated by commas." ::= { immtrapg 21 } altHostMTM OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Machine Type and Model for failing host." ::= { immtrapg 22 } altAuxData OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Auxiliary data that may be included for some events." ::= { immtrapg 23 } -- ****************************************** -- Critical Traps -- ****************************************** ibmSpTrapTempC TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "Critical Alert: Temperature threshold exceeded." ::= 0 ibmSpTrapVoltC TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "Critical Alert: Voltage threshold exceeded." ::= 1 ibmSpTrapPowerC TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "Critical Alert: Power failure." ::= 4 ibmSpTrapHdC TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "Critical Alert: Hard disk drive failure." ::= 5 ibmSpTrapFanC TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "Critical Alert: Single Fan failure." ::= 11 ibmSpTrapIhcC TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "Critical Alert: Incompatible hardware configuration." ::= 36 ibmSpTrapCPUC TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "Critical Alert: CPU Error." ::= 40 ibmSpTrapMemoryC TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "Critical Alert: Memory Error." ::= 41 ibmSpTrapRdpsC TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "Critical Alert: Redundant Power Supply failure." ::= 9 ibmSpTrapHardwareC TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "Critical Alert: Other Failure - refer to Message ID for specific condition." ::= 50 -- ****************************************** -- Non-Critical Traps -- ****************************************** ibmSpTrapRdpsN TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "Non-Critical Alert: Redundant Power Supply failure." ::= 10 ibmSpTrapTempN TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "Non-Critical Alert: Temperature threshold exceeded." ::= 12 ibmSpTrapVoltN TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "Non-Critical Alert: Voltage threshold exceeded." ::= 13 ibmSpTrapPowerN TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "Non-Critical Alert: Power." ::= 164 ibmSpTrapFanN TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "Non-Critical Alert: Fan Error." ::= 165 ibmSpTrapCPUN TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "Non-Critical Alert: CPU Error." ::= 42 ibmSpTrapMemoryN TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "Non-Critical Alert: Memory Error." ::= 43 ibmSpTrapHardwareN TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "Non-Critical Alert: Warning - refer to Message ID for specific condition." ::= 60 -- ****************************************** -- System Traps -- ****************************************** ibmSpTrapRLogin TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "Sev-Off Alert: Event Remote Login." ::= 30 ibmSpTrapOsToS TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "System Alert: OS Timeout value exceeded." ::= 21 ibmSpTrapAppS TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "System Alert: Application Alert. Refer to Message ID for specific condition." ::= 22 ibmSpTrapPoffS TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "System Alert: Power Off." ::= 23 ibmSpTrapPonS TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "System Alert: Power On." ::= 24 ibmSpTrapBootS TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "System Alert: System Boot Failure." ::= 25 ibmSpTrapLdrToS TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "System Alert: OS Loader Timeout." ::= 26 ibmSpTrapPFAS TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "System Alert: Predictive Failure Analysis(PFA) information." ::= 27 ibmSpTrapSysLogS TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "System Alert: System Log 75% full." ::= 35 ibmSpTrapNwChangeS TRAP-TYPE ENTERPRISE immalertMIB VARIABLES { altDateTime, altSpTxtId, altSysUuid, altSysSern, altMsgID, altMsgIDPrefix, altPriority, altMsgText, altHostContact, altHostLocation, altHostRoomID, altHostRackID, altHostLowestUpos, altHostBladeBay, altEventID, altServiceable, altTest, altFailingFRUs, altHostMTM, altAuxData } DESCRIPTION "System Alert: Network change notification." ::= 37 END