-- ICT MIB file for ICT Modular Power System. -- -- Date Version -- ============================= -- 1/5/18 v1.01 -- ICT-MODULAR-POWER-SYSTEM-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, IpAddress FROM RFC1155-SMI DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; ictPower OBJECT IDENTIFIER ::= { enterprises 39145 } powerSystem OBJECT IDENTIFIER ::= { ictPower 13 } deviceModel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Model Number" ::= { powerSystem 1 } deviceName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Device Name" ::= { powerSystem 2 } deviceHardware OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Hardware Version" ::= { powerSystem 3 } deviceFirmware OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Firmware Version" ::= { powerSystem 4 } deviceMacAddress OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "MAC Address" ::= { powerSystem 5 } inputVoltage OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Input Voltage (VAC)" ::= { powerSystem 6 } outputVoltage OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Output Voltage (VDC)" ::= { powerSystem 7 } outputCurrent OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Total System Current (Amps)" ::= { powerSystem 8 } outputEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Output Enable Status (a value of '1' indicates Output is Enabled, and a value of '2' indicates Output is Disabled. Output cannot be disabled during an AC Failure)" ::= { powerSystem 9 } moduleTable OBJECT-TYPE SYNTAX SEQUENCE OF ModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Module Table" ::= { powerSystem 10 } moduleEntry OBJECT-TYPE SYNTAX ModuleEntry ACCESS not-accessible STATUS mandatory INDEX { moduleNumber } ::= { moduleTable 1 } ModuleEntry ::= SEQUENCE { moduleNumber INTEGER, moduleStatus INTEGER, moduleType INTEGER, moduleVoltage DisplayString, moduleCurrentA DisplayString, moduleCurrentB DisplayString, moduleCurrentC DisplayString, moduleCurrentD DisplayString, moduleControlA INTEGER, moduleControlB INTEGER, moduleControlC INTEGER, moduleControlD INTEGER } moduleNumber OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Module Number" ::= { moduleEntry 1 } moduleStatus OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), ok(2), alarm(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Module Status" ::= { moduleEntry 2 } moduleType OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), power(2), battery(3), distribution(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Module Type ('1' indicates Module is NOT INSTALLED,'2' indicates POWER Module,'3' indicates BATTERY Module, and '4' indicates DISTRIBUTION Module)" ::= { moduleEntry 3 } moduleVoltage OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Module Voltage (VDC)" ::= { moduleEntry 4 } moduleCurrentA OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Channel 1 Current (Amps)" ::= { moduleEntry 5 } moduleCurrentB OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Channel 2 Current (Amps)" ::= { moduleEntry 6 } moduleCurrentC OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Channel 3 Current (Amps)" ::= { moduleEntry 7 } moduleCurrentD OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Channel 4 Current (Amps)" ::= { moduleEntry 8 } moduleControlA OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Channel 1 Control (a value of '1' indicates Channel is Enabled, and a value of '2' indicates Channel is Disabled)" ::= { moduleEntry 9 } moduleControlB OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Channel 2 Control (a value of '1' indicates Channel is Enabled, and a value of '2' indicates Channel is Disabled)" ::= { moduleEntry 10 } moduleControlC OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Channel 3 Control (a value of '1' indicates Channel is Enabled, and a value of '2' indicates Channel is Disabled)" ::= { moduleEntry 11 } moduleControlD OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Channel 4 Control (a value of '1' indicates Channel is Enabled, and a value of '2' indicates Channel is Disabled)" ::= { moduleEntry 12 } alarmTable OBJECT-TYPE SYNTAX SEQUENCE OF AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm Input Table" ::= { powerSystem 11 } alarmEntry OBJECT-TYPE SYNTAX AlarmEntry ACCESS not-accessible STATUS mandatory INDEX { alarmNumber } ::= { alarmTable 1 } AlarmEntry ::= SEQUENCE { alarmNumber INTEGER, alarmName DisplayString, alarmStatus INTEGER } alarmNumber OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm Input Number" ::= { alarmEntry 1 } alarmName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Alarm Input Name" ::= { alarmEntry 2 } alarmStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), ready(2), alarm(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alarm Input Status ('1' indicates Alarm is INACTIVE,'2' indicates Alarm is READY, and '3' indicates Alarm is in an ALARM condition)" ::= { alarmEntry 3 } -- -- Trap definitions: -- moduleAlarmTrap TRAP-TYPE ENTERPRISE powerSystem VARIABLES { moduleNumber } DESCRIPTION "Trap generated when a Module Alarm is triggered" ::= 101 alarmInputTrap TRAP-TYPE ENTERPRISE powerSystem VARIABLES { alarmNumber } DESCRIPTION "Trap generated when an Alarm Input is activated" ::= 102 acFailAlarmTrap TRAP-TYPE ENTERPRISE powerSystem DESCRIPTION "Trap generated when the AC Failure Alarm is triggered" ::= 103 sysCurrentLimitTrap TRAP-TYPE ENTERPRISE powerSystem DESCRIPTION "Trap generated when the System Current Limit Alarm is triggered" ::= 104 moduleAlarmClear TRAP-TYPE ENTERPRISE powerSystem VARIABLES { moduleNumber } DESCRIPTION "Trap generated when a Module Alarm is cleared" ::= 111 alarmInputClear TRAP-TYPE ENTERPRISE powerSystem VARIABLES { alarmNumber } DESCRIPTION "Trap generated when an Alarm Input is cleared" ::= 112 acFailAlarmClear TRAP-TYPE ENTERPRISE powerSystem DESCRIPTION "Trap generated when the AC Failure Alarm is cleared" ::= 113 sysCurrentLimitClear TRAP-TYPE ENTERPRISE powerSystem DESCRIPTION "Trap generated when the System Current Limit Alarm is cleared" ::= 114 batteryTestStart TRAP-TYPE ENTERPRISE powerSystem DESCRIPTION "Trap generated when a Battery Discharge Test is started" ::= 121 batteryTestComplete TRAP-TYPE ENTERPRISE powerSystem DESCRIPTION "Trap generated when a Battery Discharge Test completes successfully" ::= 122 batteryTestFail TRAP-TYPE ENTERPRISE powerSystem DESCRIPTION "Trap generated when a Battery Discharge Test fails" ::= 123 batteryEqualiseStart TRAP-TYPE ENTERPRISE powerSystem DESCRIPTION "Trap generated when a Battery Equalise Charge is started" ::= 124 batteryEqualiseComplete TRAP-TYPE ENTERPRISE powerSystem DESCRIPTION "Trap generated when a Battery Equalise Charge completes" ::= 125 END